PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0° CONTROL SETTING
Type A with Run/Start Capacitor 65°F (18°C) Ambient 90°F (32°C) Ambient
Operating Time 74 to 84% 100%
Freezer Temperature
Refrigerator Temperature
-5° to 2° F (-20° to -17° C)
34° to 39° F (1° to 4° C)
-1° to 3° F (-18° to -16° C)
34° to 39° F (1° to 4° C)
Low Side Pressure (cut-in)
Low Side Pressure (cut-out)
High Side Pressure (last 1/3 cycle)
Wattage (last 1/3 cycle)
Amps (running)
5 to 12 psig (34 to 83 kPa)
-2 to 2 psig ( -14 to 14 kPa)
85 to 95 psig (586 to 655 kPa)
45 to 55
.6 to 1.1
N/A
-2 to 2 psig (-14 to 14 kPa)
120 to 135 psig (827 to 931 kPa)
60 to 70
.7 to .9
Base Voltage
Cabinet Size
115 vac (127 vac max) deFrOst speciFicatiOns
Cut-in thermostat
Cut-out Watts
26’ & 28’ SD, 23’ CD 25° F (-4° C) 47° F (8° C) 500
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
Electrical
Thermostat
Heater Voltage
Watts
3.1
heater cOndenser Fan MOtOr rpM
1100 CW Opposite Shaft ice MaKer speciFicatiOns
115 vac (127 vac max)
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C) amps
0.03 Running
Ohms
31
Wire number
1
2
3
4
85 vac ice MaKer cOnnectOr pLUG cOnnectiOns
Wire color
Green/Yellow
Yellow
Black
Light Blue connects to:
Ground
Water Valve
Line
Neutral ice Maker errors displayed on “Ui” errOr ice ice ice ice
service data sheet
240389643
ice & Water - aUtOMatic deFrOst
BOttOM FreeZer - r134a
er IM/RAM Error (on POR only)Detection – on POR only. This error is detected as “no com/data link with
IM” by ERF 2500++ system controller (PB).
ip Invalid Protocol (this error is detected when the version of I/M pcb does not match version of 2500++ system controller)
ce IM Com Lost only after POR(no communication between the I/M pcb and the 2500++ system controller.) t3 TH3 Error (open or short) This error is detected when the thermister has failed on the suction line of the I/M.
system error codes displayed on “Ui” errOr test
Op or 2 sh or 3
Op or 2 sh or 3 sy sy sy
Freezer Sensor OPEN
Freezer Sensor SHORTED
FF Sensor OPEN
FF Sensor SHORTED eF Evaporator Fan Circuit ce Communication error cF Communication error dF In Manual Defrost
To initiate manual defrost press and hold, for 5 sec. FF(+) and FF(-), (d) and (f) will be displayed.
9
10
11
41
3
8
1
2
12
38
15 test
48c
49c
50c
51c
52c
54C
56c
55c diagnostic Mode note: see service Manual for complete description.
Activate: Hold FF (+) and FZ (+) for 5 sec.
Freezer Recover Mode, “1” ok
“Fr” Recovery mode, Icemaker in
“off” state. (See Note)
EEV On=Open Off=Closed , EEV must be in the open state for sealed system evacuation.
Com Link “1” ok “ER” error
57c
58c
59c
Fan test, on or off
Ice level sensor switch test
Fill limit switch test
(See Note)
TH1 Status “1” ok “ER” Replace 60c
TH3 Status “1” ok “ER” Replace
Mold heater test, on or off
Finger evap heater, on or off
Water valve test (See Note) de-activate: hold FF (+) for 5 sec.
61c
62c
63c
64c
Freeze limit switch test
(See Note)
IM evap heater test
EEV test
Harvest motor system test
(See Note)
Software version diagnostic Mode activate: FZ (+) and FZ (-) for
5 sec.
Standard compressor
Defrost heater
FF lighting
Water valve,water disp.
FZ lighting
Auger motor
Cube/crush solenoid
Perfect Temp Drawer
VCC Condensor fan
VCC Compressor
Evaporator fan de-activate: hold FF (+) for 5 sec.
note: see service Manual for complete description.
28
36
29
30
22
23
24
26
33
0-
Damper
Fresh food door
Freezer door
Defrost limit switch
Dispenser paddle
Ice door
FF Thermistor
FZ Thermistor
Ambient Thermistor
Software version
iMpOrtant saFety nOte
The information provided herein is designed to assist qualified repair personnel only.
Untrained persons should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before servicing this appliance.
iMpOrtant
If any green grounding wires are removed during servicing, they must be returned to their original position and properly secured.
caUtiOn
all electrical parts and wiring must be shielded from torch flame. dO nOt allow torch to touch insulation; it will char at 200°F and flash ignite (burn) at 500°F. excessive heat will distort the plastic liner.
nOte
This product comes equipped with an Adaptive Defrost Control (ADC). To activate manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A “d” in the freezer temperature window and “F” in the refrigerator temperature window will display when the heater is activated. To deactivate manual defrost, simultaneously press and hold the Fresh Food up (+) and Fresh Food down (-) keys for 5 seconds. A “d” and “F” will be displayed until the defrost cycle is complete.
iMpOrtant
pLease retUrn this sheet tO it’s OriGinaL LOcatiOn.
FREEZER iCE MAKER iNFORMATiON
Test Cycling:
Remove cover by inserting screwdriver in notch at bottom and prying cover from housing. Use screwdriver to rotate motor gear counterclockwise until holding switch circuit is completed. All components of ice maker should function to complete the cycle.
Water Fill
Adjustment
Motor
Gear
Water Fill Volume:
The water fill adjustment screw will change the fill time. One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to 4.3 oz.). When a water valve is replaced, the fill volume must be checked.
LINE POWER
ICE MAKER
P-3
P-1
Mounting
Plate
Screw
BLK BRN
THERMAL
CUT-OUT
GRN / YEL
MOLD MOUNTING
PLATE
MOTOR
RED
RED
MOLD HEATER
165 WATTS
HOLD
SWITCH
NO
C
BLK
NC
YEL
THERMOSTAT
NO
NO
C
NC
WATER FILL
SWITCH
BLU
C
NC
SHUT-OFF
SWITCH
LT. BLU
ICE MAKER
TUR
N Mounting
Plate
Screws
Timing
Gear
NEUTRAL
P-4
P-2
FF Ice Maker
(2419801)
242058901 Wiring Diagram
Frig FDBF 2500++ V4 with Dispenser
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement