SCALANCE XM-400/XR-500 Web Based Management (WBM)

SCALANCE XM-400/XR-500 Web Based Management (WBM)
SCALANCE XM-400/XR-500 Web
1
___________________
Introduction
Based Management (WBM)
2
___________________
Description
SIMATIC NET
3
___________________
IP addresses
Industrial Ethernet switches
SCALANCE XM-400/XR-500 Web
Based Management (WBM)
Configuration Manual
11/2015
C79000-G8976-C248-10
4
___________________
Technical basics
Configuring with Web Based
5
___________________
Management
6
___________________
Troubleshooting/FAQ
Legal information
Warning notice system
This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent
damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert
symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are
graded according to the degree of danger.
DANGER
indicates that death or severe personal injury will result if proper precautions are not taken.
WARNING
indicates that death or severe personal injury may result if proper precautions are not taken.
CAUTION
indicates that minor personal injury can result if proper precautions are not taken.
NOTICE
indicates that property damage can result if proper precautions are not taken.
If more than one degree of danger is present, the warning notice representing the highest degree of danger will
be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to
property damage.
Qualified Personnel
The product/system described in this documentation may be operated only by personnel qualified for the specific
task in accordance with the relevant documentation, in particular its warning notices and safety instructions.
Qualified personnel are those who, based on their training and experience, are capable of identifying risks and
avoiding potential hazards when working with these products/systems.
Proper use of Siemens products
Note the following:
WARNING
Siemens products may only be used for the applications described in the catalog and in the relevant technical
documentation. If products and components from other manufacturers are used, these must be recommended
or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and
maintenance are required to ensure that the products operate safely and without any problems. The permissible
ambient conditions must be complied with. The information in the relevant documentation must be observed.
Trademarks
All names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication
may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.
Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software
described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the
information in this publication is reviewed regularly and any necessary corrections are included in subsequent
editions.
Siemens AG
Division Process Industries and Drives
Postfach 48 48
90026 NÜRNBERG
GERMANY
C79000-G8976-C248-10
Ⓟ 11/2015 Subject to change
Copyright © Siemens AG 2011 - 2015.
All rights reserved
Table of contents
1
Introduction ............................................................................................................................................. 9
1.1
2
3
4
Information on this configuration manual .................................................................................. 9
Description ............................................................................................................................................ 13
2.1
Product characteristics............................................................................................................13
2.2
Requirements for installation and operation ...........................................................................15
2.3
C-PLUG / KEY-PLUG .............................................................................................................16
2.4
Power over Ethernet (PoE) .....................................................................................................18
IP addresses ......................................................................................................................................... 21
3.1
IPv4 / IPv6 ...............................................................................................................................21
3.2
3.2.1
3.2.2
3.2.3
IPv4 address ...........................................................................................................................23
Structure of an IPv4 address ..................................................................................................23
Initial assignment of an IPv4 address .....................................................................................24
Address assignment with DHCP .............................................................................................25
3.3
3.3.1
3.3.2
IPv6 addresses .......................................................................................................................27
IPv6 terms ...............................................................................................................................27
Structure of an IPv6 address ..................................................................................................28
Technical basics ................................................................................................................................... 31
4.1
Configuration limits .................................................................................................................31
4.2
4.2.1
VLAN .......................................................................................................................................33
VLAN tagging ..........................................................................................................................34
4.3
SNMP ......................................................................................................................................36
4.4
4.4.1
4.4.2
4.4.2.1
4.4.2.2
4.4.3
4.4.3.1
4.4.3.2
4.4.4
4.4.4.1
4.4.4.2
Routing function ......................................................................................................................38
Static routing ...........................................................................................................................38
VRRP ......................................................................................................................................39
VRRPv2 ..................................................................................................................................39
VRRP3 ....................................................................................................................................39
OSPF ......................................................................................................................................40
OSPFv2 ..................................................................................................................................40
OSPFv3 ..................................................................................................................................44
RIP ..........................................................................................................................................45
RIPv2 ......................................................................................................................................45
RIPng ......................................................................................................................................46
4.5
4.5.1
4.5.1.1
4.5.2
4.5.3
4.5.3.1
Redundancy mechanism ........................................................................................................47
Spanning Tree ........................................................................................................................47
RSTP, MSTP, CIST ................................................................................................................48
HRP.........................................................................................................................................49
MRP ........................................................................................................................................49
MRP - Media Redundancy Protocol .......................................................................................49
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
3
Table of contents
5
4.5.3.2
4.5.3.3
4.5.4
Configuration in WBM ............................................................................................................ 52
Configuration in STEP 7 ........................................................................................................ 53
Standby .................................................................................................................................. 56
4.6
Link aggregation..................................................................................................................... 58
Configuring with Web Based Management ............................................................................................ 59
5.1
Web Based Management ...................................................................................................... 59
5.2
Login ...................................................................................................................................... 61
5.3
5.3.1
5.3.2
5.3.3
5.3.4
5.3.4.1
5.3.4.2
5.3.5
5.3.6
5.3.7
5.3.7.1
5.3.7.2
5.3.7.3
5.3.7.4
5.3.7.5
5.3.8
5.3.8.1
5.3.8.2
5.3.8.3
5.3.8.4
5.3.8.5
5.3.9
5.3.10
5.3.11
5.3.12
5.3.13
5.3.13.1
5.3.13.2
5.3.13.3
5.3.13.4
5.3.13.5
5.3.13.6
5.3.14
5.3.14.1
5.3.14.2
5.3.14.3
5.3.14.4
5.3.14.5
5.3.14.6
5.3.14.7
5.3.14.8
5.3.15
5.3.16
The "Information" menu ......................................................................................................... 64
Start page............................................................................................................................... 64
Versions ................................................................................................................................. 69
Identification & Maintenance .................................................................................................. 70
ARP / Neighbors .................................................................................................................... 72
ARP Table .............................................................................................................................. 72
IPv6 Neighbor Table .............................................................................................................. 73
Log Table ............................................................................................................................... 74
Faults ..................................................................................................................................... 76
Redundancy ........................................................................................................................... 77
Spanning Tree........................................................................................................................ 77
VRRP statistics ...................................................................................................................... 80
VRRP Statistics ...................................................................................................................... 83
Ring redundancy .................................................................................................................... 85
Standby .................................................................................................................................. 87
Ethernet Statistics .................................................................................................................. 89
Interface Statistics .................................................................................................................. 89
Packet Size ............................................................................................................................ 90
Frame Type ............................................................................................................................ 91
Packet Error ........................................................................................................................... 92
History .................................................................................................................................... 94
Unicast ................................................................................................................................... 95
Multicast ................................................................................................................................. 96
LLDP ...................................................................................................................................... 98
Fiber Monitoring Protocol ....................................................................................................... 99
IPv4 routing .......................................................................................................................... 101
Routing Table ....................................................................................................................... 101
OSPFv2 Interfaces ............................................................................................................... 102
OSPFv2 Neighbors .............................................................................................................. 103
OSPFv2 Virtual Neighbors ................................................................................................... 105
OSPFv2 LSDB ..................................................................................................................... 107
RIPv2 Statistics .................................................................................................................... 108
IPv6 routing .......................................................................................................................... 109
IPv6 Routing Table .............................................................................................................. 109
OSPFv3 Interfaces ............................................................................................................... 110
OSPFv3 Neighbors .............................................................................................................. 112
OSPFv3 Virtual Neighbors ................................................................................................... 114
OSPFv3 AS-Scope LSDB .................................................................................................... 116
OSPFv3 Area-Scope LSDB ................................................................................................. 117
OSPFv3 Link-Scope LSDB .................................................................................................. 119
RIPng Statistics .................................................................................................................... 120
SNMP ................................................................................................................................... 121
Security ................................................................................................................................ 122
SCALANCE XM-400/XR-500 Web Based Management (WBM)
4
Configuration Manual, 11/2015, C79000-G8976-C248-10
Table of contents
5.3.16.1
5.3.16.2
5.3.16.3
5.3.16.4
Overview ...............................................................................................................................122
Supported Function Rights ...................................................................................................125
Roles .....................................................................................................................................126
Groups ..................................................................................................................................127
5.4
5.4.1
5.4.2
5.4.2.1
5.4.2.2
5.4.3
5.4.4
5.4.5
5.4.6
5.4.6.1
5.4.6.2
5.4.6.3
5.4.7
5.4.7.1
5.4.7.2
5.4.8
5.4.9
5.4.10
5.4.10.1
5.4.10.2
5.4.10.3
5.4.10.4
5.4.11
5.4.11.1
5.4.11.2
5.4.11.3
5.4.11.4
5.4.11.5
5.4.11.6
5.4.11.7
5.4.11.8
5.4.12
5.4.13
5.4.14
5.4.15
5.4.15.1
5.4.15.2
5.4.16
5.4.16.1
5.4.16.2
5.4.16.3
5.4.17
5.4.18
5.4.18.1
5.4.18.2
5.4.19
5.4.20
5.4.20.1
The "System" menu ..............................................................................................................128
Configuration .........................................................................................................................128
General .................................................................................................................................131
Device ...................................................................................................................................131
Coordinates ...........................................................................................................................132
Agent IP ................................................................................................................................133
DNS.......................................................................................................................................134
Restart ..................................................................................................................................136
Load & Save .........................................................................................................................137
HTTP .....................................................................................................................................137
TFTP .....................................................................................................................................141
Passwords ............................................................................................................................144
Events ...................................................................................................................................145
Configuration .........................................................................................................................145
Severity Filters ......................................................................................................................148
SMTP client ...........................................................................................................................149
DHCP client ..........................................................................................................................151
SNMP ....................................................................................................................................152
General .................................................................................................................................152
Traps .....................................................................................................................................154
v3 Groups .............................................................................................................................155
v3 users ................................................................................................................................157
System Time .........................................................................................................................159
Manual Setting ......................................................................................................................160
DST Overview .......................................................................................................................162
DST Configuration ................................................................................................................164
SNTP Client ..........................................................................................................................168
NTP Client .............................................................................................................................171
SIMATIC time client ..............................................................................................................173
PTP Client .............................................................................................................................174
PTP Client .............................................................................................................................174
Automatic logout ...................................................................................................................176
Configuration of the SELECT/SET button ............................................................................177
Syslog Client .........................................................................................................................179
Ports ......................................................................................................................................181
Overview ...............................................................................................................................181
Configuration .........................................................................................................................185
Fault Monitoring ....................................................................................................................189
Power Supply ........................................................................................................................189
Link Change ..........................................................................................................................191
Redundancy ..........................................................................................................................193
PNIO .....................................................................................................................................193
PLUG ....................................................................................................................................194
Configuration .........................................................................................................................194
License ..................................................................................................................................197
Ping .......................................................................................................................................199
PoE .......................................................................................................................................200
General .................................................................................................................................200
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
5
Table of contents
5.4.20.2
5.4.21
5.4.21.1
5.4.21.2
Port ....................................................................................................................................... 202
Port Diagnostics ................................................................................................................... 205
Cable Tester......................................................................................................................... 205
SFP diagnostics ................................................................................................................... 207
5.5
5.5.1
5.5.2
5.5.2.1
5.5.2.2
5.5.2.3
5.5.3
5.5.4
5.5.4.1
5.5.4.2
5.5.4.3
5.5.4.4
5.5.4.5
5.5.4.6
5.5.5
5.5.5.1
5.5.5.2
5.5.5.3
5.5.5.4
5.5.5.5
5.5.6
5.5.7
5.5.7.1
5.5.7.2
5.5.8
5.5.8.1
5.5.8.2
5.5.8.3
5.5.8.4
5.5.8.5
5.5.8.6
5.5.9
5.5.10
5.5.11
5.5.12
5.5.13
5.5.14
5.5.14.1
5.5.14.2
5.5.14.3
5.5.14.4
5.5.15
5.5.15.1
5.5.15.2
5.5.15.3
5.5.15.4
5.5.15.5
5.5.16
The "Layer 2" menu ............................................................................................................. 209
Configuration ........................................................................................................................ 209
QoS ...................................................................................................................................... 213
CoS queue mapping ............................................................................................................ 213
DSCP Mapping .................................................................................................................... 215
QoS Trust ............................................................................................................................. 216
Rate Control ......................................................................................................................... 218
VLAN .................................................................................................................................... 220
General ................................................................................................................................ 220
GVRP ................................................................................................................................... 223
Port-based VLAN ................................................................................................................. 225
Protocol-based VLAN group ................................................................................................ 227
Protocol-based VLAN port ................................................................................................... 228
IPv4 subnet-based VLAN ..................................................................................................... 230
Mirroring ............................................................................................................................... 231
General ................................................................................................................................ 232
Port ....................................................................................................................................... 237
VLAN .................................................................................................................................... 238
MAC Flow ............................................................................................................................. 239
IP Flow ................................................................................................................................. 240
Dynamic MAC Aging ............................................................................................................ 241
Ring redundancy .................................................................................................................. 242
Ring ...................................................................................................................................... 242
Standby ................................................................................................................................ 245
Spanning tree ....................................................................................................................... 248
General ................................................................................................................................ 248
CIST General ....................................................................................................................... 249
CIST Port ............................................................................................................................. 251
MST General ........................................................................................................................ 255
MST Port .............................................................................................................................. 256
Enhanced Passive Listening Compatibility .......................................................................... 259
Loop Detection ..................................................................................................................... 261
Link aggregation................................................................................................................... 263
DCP forwarding .................................................................................................................... 266
LLDP .................................................................................................................................... 268
Fiber Monitoring Protocol ..................................................................................................... 269
Unicast ................................................................................................................................. 271
Filtering ................................................................................................................................ 271
Locked ports......................................................................................................................... 273
Learning ............................................................................................................................... 275
Unicast blocking ................................................................................................................... 276
Multicast ............................................................................................................................... 277
Groups ................................................................................................................................. 277
IGMP .................................................................................................................................... 280
GMRP .................................................................................................................................. 282
Multicast blocking ................................................................................................................. 284
MLD (IPv6) ........................................................................................................................... 285
Broadcast ............................................................................................................................. 287
SCALANCE XM-400/XR-500 Web Based Management (WBM)
6
Configuration Manual, 11/2015, C79000-G8976-C248-10
Table of contents
5.5.17
5.5.17.1
5.5.17.2
5.5.17.3
5.5.18
5.5.18.1
5.5.18.2
PTP .......................................................................................................................................289
General .................................................................................................................................289
TC General ...........................................................................................................................290
TC Port ..................................................................................................................................290
RMON ...................................................................................................................................292
Statistics ................................................................................................................................292
History ...................................................................................................................................293
5.6
5.6.1
5.6.2
5.6.2.1
5.6.2.2
5.6.3
5.6.4
5.6.4.1
5.6.4.2
5.6.4.3
5.6.4.4
5.6.4.5
5.6.5
5.6.5.1
5.6.5.2
5.6.6
5.6.6.1
5.6.6.2
5.6.6.3
5.6.6.4
5.6.7
5.6.7.1
5.6.7.2
5.6.7.3
5.6.7.4
5.6.8
5.6.8.1
5.6.8.2
5.6.8.3
5.6.8.4
5.6.8.5
5.6.8.6
5.6.8.7
5.6.9
5.6.9.1
5.6.9.2
The "Layer 3 (IPv4)" menu....................................................................................................295
Configuration .........................................................................................................................295
Subnets .................................................................................................................................296
Overview ...............................................................................................................................296
Configuration .........................................................................................................................299
Static Routes .........................................................................................................................300
Route Maps ...........................................................................................................................302
General .................................................................................................................................302
Interface & Value Match........................................................................................................303
Destination Match .................................................................................................................305
Next Hop Match ....................................................................................................................305
Create ...................................................................................................................................306
DHCP Relay Agent ...............................................................................................................307
General .................................................................................................................................307
Option ...................................................................................................................................309
VRRP ....................................................................................................................................311
Router ...................................................................................................................................311
Configuration .........................................................................................................................314
Address overview..................................................................................................................315
Address Configuration ..........................................................................................................316
VRRPv3 ................................................................................................................................317
Router ...................................................................................................................................317
Configuration .........................................................................................................................320
Addresses Overview .............................................................................................................322
Addresses Configuration ......................................................................................................323
OSPFv2 ................................................................................................................................324
Configuration .........................................................................................................................324
Areas .....................................................................................................................................326
Area Range ...........................................................................................................................327
Interfaces ..............................................................................................................................329
Interface Authentication ........................................................................................................331
Virtual Links ..........................................................................................................................333
Virtual Link Authentication ....................................................................................................335
RIPv2 ....................................................................................................................................337
Configuration .........................................................................................................................337
Interfaces ..............................................................................................................................338
5.7
5.7.1
5.7.2
5.7.3
5.7.3.1
5.7.3.2
5.7.4
5.7.5
The "Layer 3 (IPv6)" menu....................................................................................................340
Configuration .........................................................................................................................340
Subnets .................................................................................................................................341
DHCPv6 client .......................................................................................................................343
DHCPv6 client .......................................................................................................................343
DHCPv6 PD Sub Client ........................................................................................................344
Static Routes .........................................................................................................................346
Route maps ...........................................................................................................................348
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
7
Table of contents
6
5.7.5.1
5.7.5.2
5.7.5.3
5.7.5.4
5.7.5.5
5.7.6
5.7.6.1
5.7.6.2
5.7.6.3
5.7.7
5.7.7.1
5.7.7.2
5.7.7.3
5.7.7.4
5.7.8
5.7.8.1
5.7.8.2
5.7.8.3
5.7.8.4
5.7.8.5
5.7.9
5.7.9.1
5.7.9.2
General ................................................................................................................................ 348
Interface & Value Match ....................................................................................................... 349
Destination Match ................................................................................................................ 351
Next-Hop filtern .................................................................................................................... 351
Einstellen ............................................................................... Fehler! Textmarke nicht definiert.
DHCPv4 Relay Agent .......................................................................................................... 354
Interfaces ............................................................................................................................. 354
Server Addresses................................................................................................................. 356
Outgoing Interfaces .............................................................................................................. 357
VRRPv3 ............................................................................................................................... 358
Routers ................................................................................................................................. 358
Configuration ........................................................................................................................ 360
Addresses Overview ............................................................................................................ 362
Addresses Configuration ...................................................................................................... 363
OSPFv3 ................................................................................................................................ 364
Configuration ........................................................................................................................ 364
Areas .................................................................................................................................... 366
Area ...................................................................................................................................... 368
Interfaces ............................................................................................................................. 370
Virtual Links.......................................................................................................................... 372
RIPng ................................................................................................................................... 374
RIPng Configuration ............................................................................................................. 374
RIPng interfaces................................................................................................................... 376
5.8
5.8.1
5.8.2
5.8.2.1
5.8.2.2
5.8.2.3
5.8.3
5.8.4
5.8.4.1
5.8.4.2
5.8.4.3
5.8.5
5.8.5.1
5.8.5.2
5.8.5.3
5.8.6
5.8.6.1
5.8.6.2
5.8.6.3
5.8.6.4
5.8.7
The "Security" menu ............................................................................................................ 377
User management ............................................................................................................... 377
Users .................................................................................................................................... 380
Roles .................................................................................................................................... 380
Groups ................................................................................................................................. 382
Local Users .......................................................................................................................... 384
Passwords ............................................................................................................................ 387
AAA ...................................................................................................................................... 389
General ................................................................................................................................ 389
RADIUS Client ..................................................................................................................... 390
802.1x Authenticator ............................................................................................................ 393
MAC ACL ............................................................................................................................. 397
Rules Configuration ............................................................................................................. 397
Ingress Rules ....................................................................................................................... 398
Egress Rules ........................................................................................................................ 400
IP ACL .................................................................................................................................. 401
Rules Configuration ............................................................................................................. 401
Protocol Configuration ......................................................................................................... 403
Ingress Rules ....................................................................................................................... 404
Egress Rules ........................................................................................................................ 407
Management ACL ................................................................................................................ 410
Troubleshooting/FAQ ...........................................................................................................................413
6.1
Firmware update via WBM or CLI not possible ................................................................... 413
Index ...................................................................................................................................................415
SCALANCE XM-400/XR-500 Web Based Management (WBM)
8
Configuration Manual, 11/2015, C79000-G8976-C248-10
1
Introduction
1.1
Information on this configuration manual
Validity of the configuration manual
This Configuration Manual covers the following products:
● SCALANCE XR-500
– SCALANCE XR524-8C
– SCALANCE XR526-8C
– SCALANCE XR528-6M
– SCALANCE XR552-12M
The devices are available with or without routing functions. The routing function can
either be integrated in the devices or made available with a key plug.
● SCALANCE XM-400
– SCALANCE XM408-4C
– SCALANCE XM408-8C
– SCALANCE XM416-4C
The devices are available with or without routing functions. The routing function can
either be integrated in the devices or made available with a key plug.
This Configuration Manual applies to the following software version:
● SCALANCE XR-500 firmware as of version 5.1
● SCALANCE XM-400 firmware as of version 5.1
Purpose of the Configuration Manual
This Configuration Manual is intended to provide you with the information you require to
install, commission and operate IE switches. It provides you with the information you require
to configure the IE switches.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
9
Introduction
1.1 Information on this configuration manual
Orientation in the documentation
Apart from this configuration manual, the products also have the following documentation:
● Configuration Manual:
– SCALANCE XM-400/XR-500 Command Line Interface (CLI)
This document contains the CLI commands that are supported by the IE switches
SCALANCE XM-400 and SCALANCE X-500.
● Operating instructions:
– SCALANCE XR-500
– MM900 media modules for SCALANCE XR-500M
– Fan unit FAN597-1 for SCALANCE XR-500M
– Power supply PS598-1 for SCALANCE XR-500M
– SCALANCE XM-400
– Extender for SCALANCE XM-400
– Pluggable transceiver SFP/SFP+/SCP/STP
– PoE power supply SCALANCE PS9230 PoE / SCALANCE PS924 PoE
These documents contain information on installing and connecting up and approvals for
the products.
The following documentation is also available from SIMATIC NET on the topic of Industrial
Ethernet:
● System manual "Industrial Ethernet / PROFINET"
● System manual "Industrial Ethernet / PROFINET - Passive network components"
All these documents are available on the SCALANCE X DVD.
Terms used
The designation . . .
stands for . . .
IE switch
Industrial Ethernet switch
IPv4 address
IPv4 address
IPv6 address
IPv6 address
IP address
IPv4 / IPv6 address
IPv4 interface
Interface that supports IPv4.
IPv6 interface
Interface that supports IPv6. The interface can have more
than one IPv6 address The IPv6 addresses have different
ranges (scope), e.g. link local
IP interface
Interface that supports both IPv4 and IPv6. As default the
IPv4 support is already activated. The IPv6 support needs to
be activated extra.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
10
Configuration Manual, 11/2015, C79000-G8976-C248-10
Introduction
1.1 Information on this configuration manual
What's new as of version 5.1?
Below, you will find an overview of the most important function expansions:
● Configuration of IPv6 functionalities.
– Information > IPv6 routing
– Information > ARP / Neighbors > IPv6 Neighbor Table
– Information > Redundancy > VRRPv3 Statistics
– Layer 2 > Multicast > MLD
– Layer 3 (IPv4) > VRRPv3
– Layer 3 (IPv6)
● Managing user accounts
– Information > Security
– Security > User Accounts
● Fiber Monitoring
– Information > FMP
– Layer 2 > FMP
SIMATIC NET glossary
Explanations of many of the specialist terms used in this documentation can be found in the
SIMATIC NET glossary.
You will find the SIMATIC NET glossary here:
● SIMATIC NET Manual Collection or product DVD
The DVD ships with certain SIMATIC NET products.
● On the Internet under the following address:
50305045 (http://support.automation.siemens.com/WW/view/en/50305045)
Security information
Siemens provides products and solutions with industrial security functions that support the
secure operation of plants, solutions, machines, equipment and/or networks. They are
important components in a holistic industrial security concept. With this in mind, Siemens’
products and solutions undergo continuous development. Siemens recommends strongly
that you regularly check for product updates.
For the secure operation of Siemens products and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept) and integrate each component into a holistic,
state-of-the-art industrial security concept. Third-party products that may be in use should
also be considered. For more information about industrial security, visit
http://www.siemens.com/industrialsecurity.
To stay informed about product updates as they occur, sign up for a product-specific
newsletter. For more information, visit http://support.automation.siemens.com.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
11
Introduction
1.1 Information on this configuration manual
License conditions
Note
Open source software
Read the license conditions for open source software carefully before using the product.
You will find license conditions in the following documents on the supplied data medium:
● DOC_OSS-SCALANCE-X_74.pdf
● DC_LicenseSummaryScalanceXM400_76.pdf
● DC_LicenseSummaryScalanceXR500_76.pdf
You will find these documents on the product DVD in the following directory: /Open Source
Information
Trademarks
The following and possibly other names not identified by the registered trademark sign ® are
registered trademarks of Siemens AG:
SIMATIC NET, SCALANCE, C-PLUG, OLM
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
12
Configuration Manual, 11/2015, C79000-G8976-C248-10
2
Description
2.1
Product characteristics
Properties of the IE switches
● The Ethernet interfaces support the following modes:
– 10 Mbps and 100 Mbps both in full and half duplex
– 1000 Mbps full duplex
– Autocrossing
– Autopolarity
● Redundancy protocols Multiple Spanning Tree Protocol (MSTP), Rapid Spanning Tree
Protocol (RSTP) and Spanning Tree Protocol (STP)
This means part of a network can be connected redundantly to a higher-level company
network. The reconfiguration time of the network is in the seconds range and therefore
takes longer than the ring redundancy method.
● Virtual networks (VLAN)
To structure Industrial Ethernet networks with a fast growing number of nodes, a physical
network can be divided into several virtual subnets. Port-based, protocol-based and
subnet-based VLANs are available.
● Load limitation when using multicast protocols, for example video transmission
By learning the multicast sources and destinations (IGMP snooping, IGMP querier), the
IE switches can filter multicast data traffic and limit the load in the network. Multicast and
broadcast data traffic can be limited.
● Time-of-day synchronization
Diagnostics messages (log table entries, e-mails) are given a time stamp. The local time
is uniform throughout the network thanks to synchronization with a SICLOCK time
transmitter or SNTP/NTP/PTP server and therefore makes the identification of
diagnostics messages of several devices easier.
● Link aggregation (IEEE 802.1AX) for bundling ports
● Quality of Service for classification of the network traffic is according to COS (Class of
Service - IEEE 802.11Q) and DSCP (Differentiated Services Code Point - RFC 2474)
Layer 3 functions
The following functions are only available on devices with routing functions:
● Static routing
● OSPF / OSPFv3
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
13
Description
2.1 Product characteristics
● VRRP / VRRPv3
● RIP / RIPng
There are devices that natively support all routing functions. You will find the order numbers
in the operating instructions of the devices.
On the devices that only support layer 2, you can enable the routing functions with a KEYPLUG.
IPv6 addresses
As of firmware version 5.0 you can configure IPv6 functionalities using the Command Line
Interface. As of firmware version 5.1 you can configure IPv6 functionalities in the Web Based
Management. You can recognize IPv6 addresses by the name "Subnet Mask/Prefix2.
Naming interfaces
Interface names with SCALANCE XM-400
● Interfaces of the basic device
The interfaces of the basic device SCALANCE XM-400 are called module 1.
● Interfaces of extenders
The port extenders are called module 2 and module 3 starting from the basic device. The
number of port extenders depends on the number of ports of the basic device.
The extender function is called module 0.
Interface names with SCALANCE XR-500
● Permanently integrated Interfaces
The interfaces permanently installed in the SCALANCE XR-500 are identified with
module 0.
● Interfaces of modules
The slots for modules are called module 1 followed by numbers. The numbering range
depends on the hardware configuration. The numbering is fixed and does not depend on
the number of modules being used.
Each module has 4 ports numbered 1 to 4.
Combo ports
Combo port is the name for two communication ports. A combo port has the two following
plug-in options:
● a fixed RJ-45 port
● an SFP transceiver slot that can be equipped individually
Of these two ports, only one can ever be active.
You can set the active port with the command media-type.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
14
Configuration Manual, 11/2015, C79000-G8976-C248-10
Description
2.2 Requirements for installation and operation
2.2
Requirements for installation and operation
Requirements for installation and operation of the IE switches
A PG/PC with a network connection must be available in order to configure the IE switches.
If no DHCP server is available, a PG/PC on which the Primary Setup Tool (PST) is installed
is necessary for the initial assignment of an IP address to the IE switches. For the other
configuration settings, a PG/PC with Telnet or an Internet browser is necessary.
Serial interface
The IE switches have a serial interface. An IP address is unnecessary to be able to access
the device via the serial interface. A serial cable ships with the products.
Set the following parameters for the connection:
● Bits per second: 115200
● Data bits: 8
● Parity: None
● Stop bits: 1
● Flow control: None
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
15
Description
2.3 C-PLUG / KEY-PLUG
2.3
C-PLUG / KEY-PLUG
Configuration information on the C-PLUG / KEY-PLUG
The C-PLUG / KEY-PLUG is used to transfer the configuration of the old device to the new
device when a device is replaced.
NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A C-PLUG / KEY-PLUG may only be removed or inserted when the device is turned off.
The device regularly checks whether or not a KEY-PLUG is present. If it is detected that the
KEY-PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted in the
device, the device changes to a defined error state following the restart.
When the new device starts up with the C-PLUG / KEY-PLUG, it then continues
automatically with exactly the same configuration as the old device. One exception to this
can be the IP configuration if it is set over DHCP and the DHCP server has not been
reconfigured accordingly.
A reconfiguration is necessary if you use functions based on MAC addresses.
Note
In terms of the C-PLUG / KEY-PLUG, the SCALANCE devices work in two modes:
• Without C-PLUG / KEY-PLUG
The device stores the configuration in internal memory. This mode is active when no CPLUG / KEY-PLUG is inserted.
• With C-PLUG / KEY-PLUG
The configuration stored on the C-PLUG / KEY-PLUG is displayed over the user
interfaces. If changes are made to the configuration, the device stores the configuration
directly on the C-PLUG / KEY-PLUG and in the internal memory. This mode is active as
soon as a C-PLUG / KEY-PLUG is inserted. When the device is started with a C-PLUG /
KEY-PLUG inserted, the device starts up with the configuration data on the C-PLUG /
KEY-PLUG.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
16
Configuration Manual, 11/2015, C79000-G8976-C248-10
Description
2.3 C-PLUG / KEY-PLUG
Note
Incompatibility with previous versions with C-PLUG / KEY-PLUG inserted
During the installation of a previous version of the firmware, the configuration data can be
lost. In this case, the device starts up with the factory settings after the firmware has been
installed. In this situation, if a C-PLUG / KEY-PLUG is inserted in the device, following the
restart, this has the status "Not Accepted" since the C-PLUG / KEY-PLUG still has the
configuration data of the previous more up-to-date firmware. This allows you to return to the
previous, more up-to-date firmware without any loss of configuration data. If the original
configuration on the C-PLUG / KEY-PLUG is no longer required, the C-PLUG / KEY-PLUG
can be deleted or rewritten manually.
License information on the KEY-PLUG
In addition to the configuration, the KEY-PLUG also contains a license that allows the use of
layer 3 functions.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
17
Description
2.4 Power over Ethernet (PoE)
2.4
Power over Ethernet (PoE)
General
"Power over Ethernet" (PoE) is a power supply technique for network components according
to IEEE 802.3af or IEEE 802.3at. The power is supplied over the Ethernet cables that
connect the individual network components together. This makes an additional power cable
unnecessary. PoE can be used with all PoE-compliant network components that require a
power of max. 25.50 W.
Cable used for the power supply
● Alternative A (redundant wires)
In Fast Ethernet, the wire pairs 1, 2 and 3, 6 are used to transfer data. Pairs 4, 5 and 7, 8
are then used to supply power. If there are only four wires available, the voltage is
modulated onto the wires 1, 2 and 3, 6 (see variant 2). This alternative is suitable for a
data transmission rate of 10/100 Mbps. This type of power supply is not suitable for 1
Gbps since with gigabit all eight wires are used for data transfer.
● Alternative B (phantom power)
With phantom power, the power is supplied over the pairs that are used for data transfer,
in other words, all eight (1 Gbps) or four (10/100 Mbps) wires are used both for the data
transfer and the power supply.
A PoE-compliant end device must support both alternative A and alternative B over
redundant wires.
A switch with PoE capability can supply the end device either using
● alternative A or
● Alternative B or
● alternative A and alternative B.
Note
The SCALANCE PE408PoE extender supports alternative B.
Endspan
With endspan, the power is supplied via a switch that can reach a device over an Ethernet
cable. The switch must be capable of PoE, for example a SCALANCE X108PoE,
SCALANCE X308-2M PoE, all SCALANCE XM400 switches with PE408PoE,
SCALANCE XR552-12M.
Midspan
Midspan is used when the switch is not PoE-compliant. The power is supplied by an
additional device between the switch and end device. In this case, only data rates of 10/100
Mbps can be achieved because the power is supplied on redundant wires.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
18
Configuration Manual, 11/2015, C79000-G8976-C248-10
Description
2.4 Power over Ethernet (PoE)
A Siemens power insert can also be used as the interface for the power input. Since a power
insert supports a power supply of 24 VDC, it does not conform with IEEE 802.3af or IEEE
802.3at. The following restrictions relating to the use of power inserts should be noted:
WARNING
Operate the power insert only when the following conditions apply:
• with extra low voltages SELV, PELV complying with IEC 60364-4-41
• in USA/CAN with power supplies complying with NEC class 2
• in USA/CAN, the cabling must meet the requirements of NEC/CEC
• Current load maximum 0.5 A
Cable lengths
Table 2- 1
Permitted cable lengths (copper cable - Fast Ethernet)
Cable type
Accessory (plug, outlet,
TP cord)
Permitted cable length
IE TP torsion cable
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 45 m
+ 10 m TP cord
with IE FC RJ-45 Plug 180
0 to 55 m
IE FC TP Marine Cable
IE FC TP Trailing Cable
IE FC TP Flexible Cable
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 75 m
+ 10 m TP cord
with IE FC RJ-45 Plug 180
0 to 85 m
IE FC TP standard cable
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 90 m
+ 10 m TP cord
with IE FC RJ-45 Plug 180
0 to 100 m
Table 2- 2
Permitted cable lengths (copper cable - gigabit Ethernet)
Cable type
Accessory (plug, outlet,
TP cord)
Permitted cable length
IE FC standard cable, 4×2, 24
AWG
IE FC flexible cable, 4×2, 24
AWG
with IE FC RJ-45 Plug 180,
4x2
0 to 90 m
IE FC standard cable, 4×2, 22
AWG
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 60 m
+ 10 m TP cord
IE FC flexible cable, 4×2, 22
AWG
with IE FC Outlet RJ-45
+ 10 m TP cord
0 to 90 m
+ 10 m TP cord
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
19
Description
2.4 Power over Ethernet (PoE)
Table 2- 3
Fitting connectors
PIN
IE FC outlet RJ-45
IE FC RJ-45 modular
outlet
Use
1000BaseT
10BaseT, 100BaseTX
1
Yellow
Green/white
D1+
Tx+
2
Orange
Green
D1-
Rx+
3
White
Orange/white
D2+
Tx-
6
Blue
Orange
D2-
Rx-
4
-
Blue
D3-
-
5
-
Blue/white
D3+
-
7
-
Brown/white
D4-
-
8
-
Brown
D4+
-
SCALANCE XM-400/XR-500 Web Based Management (WBM)
20
Configuration Manual, 11/2015, C79000-G8976-C248-10
3
IP addresses
3.1
IPv4 / IPv6
What are the essential differences?
IPv4
IP configuration
•
DHCP server
•
Manual
IPv6
•
Automatic:
–
Creates a link local address for every interface on
which IPv6 is activated.
–
Stateless Address Autoconfiguration (SLAAC): Stateless autoconfiguration using NDP (Neighbor Discovery Protocol)
•
Manual
•
Stateful DHCPv6
Available IP addresses
32-bit: 4, 29 * 109 addresses
128-bit: 3, 4 * 1038 addresses
Address format
Decimal: 192.168.1.1
Hexadecimal: 2a00:ad80::0123
with port: 192.168.1.1:20
with port: [2a00:ad80::0123]:20
Loopback
127.0.0.1
::1
IP addresses of the interface
4 IP addresses
Multiple IP addresses
Header
•
LLA: A link local address (formed automatically)
fe80::/128 per interface
•
ULA: Several unique local unicast addresses per interface
•
GUA: Several global unicast addresses per interface
•
Checksum
•
Checking at a higher layer
•
Variable length
•
Fixed size
•
Fragmentation in the
header
•
Fragmentation in the extension header
•
No security
Fragmentation
Host and router
Only endpoint of the communication
Quality of service
Type of Service (ToS) for
prioritization
The prioritization is specified in the header field "Traffic
Class".
Types of frame
Broadcast, multicast,
unicast
Multicast, unicast, anycast
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
21
IP addresses
3.1 IPv4 / IPv6
Identification of DHCP clients/server
IPv4
IPv6
Client ID:
DUID + IAID(s) = exactly one interface of the host
MAC address
DUID = DHCP unique identifier
Identifies server and clients uniquely and should not change,
not even when replacing network components!
IAID = Identity Association Identifier
At least one per interface is generated by the client and remains unchanged when the DHCP client restarts
Three methods of obtaining the DUID
•
DHCP
via UDP with broadcast
DUID-LLT
•
DUID-EN
•
DUID-LL
via UDP with unicast
RFC 3315, RFC 3363
Stateful DHCPv6
Status-dependent configuration in which the IPv6 address
and the configuration settings are transferred.
Four DHVPv6 messages are exchanged between client and
server:
1. SOLICIT:
Sent by the DHCPv6 client to localize DHCPv6 servers.
2. ADVERTISE
The available DHCPv6 servers reply to this.
3. REQUEST
The DHCPv6 client requests an IPv6 address and the
configuration settings from the DHCPv6 server.
4. REPLY
The DHCPv6 server sends the IPv6 address and the configuration settings.
If the client and server support the function "Rapid commit"
the procedure is shortened to two DHCPv6 messages
SOLICIT and REPLY .
Stateless autoconfiguration
In stateless DHCPv6, only the configuration settings are
transferred.
Prefix delegation
The DHCPv6 server delegates the distribution of IPv6 prefixes to the DHCPv6 client. The DHCPv6 client is also known
as PD router.
Resolution of IP addresses in
hardware addresses
ARP (Address Resolution
Protocol)
NDP (Neighbor Discovery Protocol)
SCALANCE XM-400/XR-500 Web Based Management (WBM)
22
Configuration Manual, 11/2015, C79000-G8976-C248-10
IP addresses
3.2 IPv4 address
3.2
IPv4 address
3.2.1
Structure of an IPv4 address
Address classes
IP address range
Max. number of networks
1.x.x.x through 126.x.x.x
Class
CIDR
126
16777214
A
/8
16383
65534
B
/16
2097151
254
C
/24
128.0.x.x through 191.255.x.x
192.0.0.x through 223.255.255.x
Max. number of
hosts/network
224.0.0.0 - 239.255.255.255
Multicast applications
D
240.0.0.0 - 255.255.255.255
Reserved for future applications
E
An IP address consists of 4 bytes. Each byte is represented in decimal, with a dot separating
it from the previous one. This results in the following structure, where XXX stands for a
number between 0 and 255:
XXX.XXX.XXX.XXX
The IP address is made up of two parts, the network ID and the host ID. This allows different
subnets to be created. Depending on the bytes of the IP address used as the network ID and
those used for the host ID, the IP address can be assigned to a specific address class.
Subnet mask
The bits of the host ID can be used to create subnets. The leading bits represent the address
of the subnet and the remaining bits the address of the host in the subnet.
A subnet is defined by the subnet mask. The structure of the subnet mask corresponds to
that of an IP address. If a "1" is used at a bit position in the subnet mask, the bit belongs to
the corresponding position in the IP address of the subnet address, otherwise to the address
of the computer.
Example of a class B network:
The standard subnet address for class B networks is 255.255.0.0; in other words, the last
two bytes are available for defining a subnet. If 16 subnets must be defined, the third byte of
the subnet address must be set to 11110000 (binary notation). In this case, this results in the
subnet mask 255.255.240.0.
To find out whether two IP addresses belong to the same subnet, the two IP addresses and
the subnet mask are ANDed bit by bit. If both logic operations have the save result, both IP
addresses belong to the same subnet, for example, 141.120.246.210 and 141.120.252.108.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
23
IP addresses
3.2 IPv4 address
Outside the local area network, the distinction between network ID and host ID is of no
significance, in this case packets are delivered based on the entire IP address.
Note
In the bit representation of the subnet mask, the "ones" must be set left-justified; in other
words, there must be no "zeros" between the "ones".
3.2.2
Initial assignment of an IPv4 address
Configuration options
An initial IP address for an IE switch cannot be assigned using Web Based Management
(WBM) because this configuration tool can only be used if an IP address already exists.
The following options are available to assign an IP address to an unconfigured device:
● DHCP (default)
● Primary Setup Tool (PST)
– To be able to assign an IP address to the IE switch with the PST, it must be possible
to reach the IE switch via Ethernet.
– You will find the PST at Siemens Industry Automation and Drives Service & Support
on the Internet under the entry ID 19440762
(http://support.automation.siemens.com/WW/view/en/19440762).
– For further information about assigning the IP address with the PST, refer to the
documentation "Primary Setup Tool (PST)".
● STEP 7
In STEP 7, you can configure the topology, the device name and the IP address. If you
connect an unconfigured IE switch to the controller, the controller assigns the configured
device name and the IP address to the IE switch automatically.
– STEP 7 Classic
For further information on the assignment of the IP address using STEP 7 refer to the
documentation "Configuring Hardware and Communication Connections STEP 7", in
the section "Steps For Configuring a PROFINET IO System".
– STEP 7 Basic as of V12 SP1 or STEP 7 Professional as of V12 SP1
For further information on assigning the IP address using STEP 7 (as of V12 SP1),
refer to the online help "Information system", section "Addressing PROFINET
devices".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
24
Configuration Manual, 11/2015, C79000-G8976-C248-10
IP addresses
3.2 IPv4 address
● CLI via the serial interface
For further information on assigning the IP address using the CLI, refer to the
documentation "SCALANCE XM-400/XR-500 Command Line Interface".
● NCM PC
For further information on assigning the IP address using NCM PC, refer to the
documentation "Commissioning PC stations - Manual and Quick Start", in the section
"Creating a PROFINET IO system".
Note
When the product ships and following "Restore Factory Defaults and Restart", DHCP is
enabled. If a DHCP server is available in the local area network, and this responds to the
DHCP request of an IE switch, the IP address, subnet mask and gateway are assigned
automatically when the device first starts up.
3.2.3
Address assignment with DHCP
Properties of DHCP
DHCP (Dynamic Host Configuration Protocol) is a method for automatic assignment of IP
addresses. It has the following characteristics:
● DHCP can be used both when starting up a device and during ongoing operation.
● The assigned IP address remains valid only for a limited time known as the lease time.
Once this period has elapsed, the client must either request a new IP address or extend
the lease time of the existing IP address.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
25
IP addresses
3.2 IPv4 address
● There is normally no fixed address assignment; in other words, when a client requests an
IP address again, it normally receives a different address from the previous address. It is
possible to configure the DHCP server so that the DHCP client always receives the same
fixed address in response to its request. The parameter with which the DHCP client is
identified for the fixed address assignment is set on the DHCP client. The address can be
assigned via the MAC address, the DHCP client ID or the system name. You configure
the parameter in "System > DHCP Client".
● The following DHCP options are supported:
– DHCP option 6: Assignment of a DNS server address
– DHCP option 66: Assignment of a dynamic TFTP server name
– DHCP option 67: Assignment of a dynamic boot file name
– DHCP option 82: Assignment of IP addresses depending on the switch port or the
VLAN ID
Note
DHCP uses a mechanism with which the IP address is assigned for only a short time
(lease time). If the device does not reach the DHCP server with a new request on expiry
of the lease time, the assigned IP address, the subnet mask and the gateway continue to
be used.
The device therefore remains accessible under the last assigned IP address even without
a DHCP server. This is not the standard behavior of office devices but is necessary for
problem-free operation of the plant.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
26
Configuration Manual, 11/2015, C79000-G8976-C248-10
IP addresses
3.3 IPv6 addresses
3.3
IPv6 addresses
3.3.1
IPv6 terms
Network node
A network node is a device that is connected to one or more networks via one or more
interfaces.
Router
A network node that forwards IPv6 packets.
Host
A network node that represents an end point for IPv6 communication relations.
Link
A link is, according to IPv6 terminology, a direct layer 3 connection within an IPv6 network.
Neighbor
A network node located on the same link as the network node.
IPv6 interface
Physical or logical interface on which IPv6 is activated.
Path MTU
Maximum permitted packet size on a path from a sender to a recipient.
Path MTU discovery
Mechanism for determining the maximum permitted packet size along the entire path from a
sender to a recipient.
LLA
Link local address FE80::/10
As soon as IPv6 is activated on the interface, a link local address is formed automatically.
Can only be reached by accounts located on the same link.
ULA
Unique Local Address
Defined in RFC 4193. Via this address, the IPv6 interface can be reached in the LAN.
GUA
Global Unicast Address Via this address, the IPv6 interface can be reached, e.g. via the
Internet.
Interface ID
The interface ID is formed with the EUI-64 method or manually.
EUI-64
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
27
IP addresses
3.3 IPv6 addresses
Extended Unique Identifier (RFC 4291); method for forming the interface ID. In Ethernet, the
interface ID is formed from the MAC address of the interface. Divides the MAC address into
the manufacturer-specific part (OUI) and the network-specific part (NIC) and inserts FFFE
between the two parts.
Example:
MAC address = AA:BB:CC:DD:EE:FF
OUI = AA:BB:CC
NIC = DD:EE:FF
EUI-64 = OUI + FFFE + NIC = AA:BB:CC:FF:FE:DD:EE:FF
Scope
Defines the range of the IPv6 address.
3.3.2
Structure of an IPv6 address
IPv6 address format - notation
IPv6 addresses consist of 8 fields each with four-character hexadecimal numbers (128 bits in
total). The fields are separated by a colon.
Example:
fd00:0000:0000:ffff:02d1:7d01:0000:8f21
Rules / simplifications:
● If one or more fields have the value 0, a shortened notation is possible.
The address fd00:0000:0000:ffff:02d1:7d01:0000:8f21 can also be shortened and written
as follows:
fd00::ffff:02d1:7d01:0000:8f21
To ensure uniqueness, this shortened form can only be used once within the entire
address.
● Leading zeros within a field can be omitted.
The address fd00:0000:0000:ffff:02d1:7d01:0000:8f21 can also be shortened and written
as follows:
fd00::ffff:2d1:7d01:0000:8f21
● Decimal notation with periods
The last 2 fields or 4 bytes can be written in the normal decimal notation with periods.
Example: The IPv6 address fd00::ffff.125.1.0.1 is equivalent to fd00::ffff:7d01:1
SCALANCE XM-400/XR-500 Web Based Management (WBM)
28
Configuration Manual, 11/2015, C79000-G8976-C248-10
IP addresses
3.3 IPv6 addresses
Structure of the IPv6 address
The IPv6 protocol distinguishes three types of address: Unicast , anycast and multicast. The
following section describes the structure of the global unicast addresses.
IPv6 prefix
Suffix
Global prefix:
Subnet ID
Interface ID
n bits
m bits
128 - n - m bits
Assigned address
range
Description of the location, also
subnet prefix or subnet
Unique assignment of the host in the network.
The ID is generated from the MAC address.
The prefix for the link local address is always fe80:0000:0000:0000. The prefix is shortened
and noted as follows: fe80::
IPv6 prefix
Specified in: RFC 4291
The IPv6 prefix represents the subnet identifier.
Prefixes and IPv6 addresses are specified in the same way as with the CIDR notation
(Classless Inter-Domain Routing) for IPv4.
Design
IPv6 address / prefix length
Example
IPv6 address: 2001:0db8:1234::1111/48
Prefix: 2001:0db8:1234::/48
Interface ID: ::1111
Entry and appearance
The entry of IPv6 addresses is possible in the notations described above. IPv6 addresses
are always shown in the hexadecimal notation.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
29
IP addresses
3.3 IPv6 addresses
SCALANCE XM-400/XR-500 Web Based Management (WBM)
30
Configuration Manual, 11/2015, C79000-G8976-C248-10
4
Technical basics
4.1
Configuration limits
Configuration limits of the device
The following table lists the configuration limits for Web Based Management and the
Command Line Interface of the device.
The usability of various functions depends on the device type you are using and whether or
not a KEY-PLUG is inserted.
Configurable function
System
Syslog server
E-mail server
SNMPv1 trap recipient
SNTP server
NTP server
Layer 2
Virtual LANs (port-based; including VLAN 1)
Protocol-based VLAN groups
Protocol-based VLAN groups per port
IPv4 subnet-based VLANs
Multiple Spanning Tree instances
Link aggregations or Etherchannels each with a maximum of 8
ports per aggregation
Ports in a link aggregation
3
3
10
1
1
257
12
12
150
16
8
8
Static MAC addresses in the Forward Database (FDB)
256
Multicast addresses without active GMRP
512
Multicast addresses with active GMRP
VLANs whose data traffic can be mirrored to a monitor port
RSPAN sessions
Layer 3
Maximum number
IP interfaces
Entries in the hardware routing table
Static routes
Possible routes to the same destination
DHCP Relay Agent interfaces
DHCP Relay Agent servers
VRRP router interfaces (only VLAN interfaces)
50
255
1
127
4096
100
8
127
4
52
OSPF areas per device
5
OSPFv2 area range entries per OSPF area (intra-area summary)
3
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
31
Technical basics
4.1 Configuration limits
Configurable function
Maximum number
OSPFv3 area range entries per OSPF area (intra-area summary)
10
OSPF interfaces
40
OSPF interfaces per OSPF area
40
OSPF virtual links (within an autonomous system)
8
OSPFv3 neighbors
300
OSPFv3 neighbors per interface
8
OSPFv3 routes
1500
OSPFv2 interfaces authentication keysl
200
(40 interfaces each with 5
keys)
OSPFv2 virtual links authentication keys
40
(8 virtual links each with
5 keys)
Security IP addresses from RADIUS servers
3
Management ACLs (access rules for management)
10
Rules for port ACL MAC
128
Ingress and egress rules for port ACL MAC (total)
364
Rules for port ACL IP
128
Ingress and egress rules for port ACL IP (total)
364
Rules for VLAN ACL IP
128
Note
Restriction of the number of rules
If you change one of the following values on the "Security > ACL IP Protocol Configuration"
page, a comparator is required in each case.
• Source Port Min.
• Source Port Max.
• Dest. Port Min.
• Dest. Port Max.
Per port and transmission direction (ingress/egress) you can use 8 comparators.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
32
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.2 VLAN
4.2
VLAN
Network definition regardless of the spatial location of the nodes
VLAN (Virtual Local Area Network) divides a physical network into several logical networks
that are shielded from each other. Here, devices are grouped together to form logical groups.
Only nodes of the same VLAN can address each other. Since multicast and broadcast
frames are only forwarded within the particular VLAN, they are also known as broadcast
domains.
The particular advantage of VLANs is the reduced network load for the nodes and network
segments of other VLANs.
To identify which packet belongs to which VLAN, the frame is expanded by 4 bytes (VLAN
tagging (Page 34)). This expansion includes not only the VLAN ID but also priority
information.
Options for the VLAN assignment
There are various options for the assignment to VLANs:
● Port-based VLAN
Each port of a device is assigned a VLAN ID. You configure port-based VLAN in "Layer 2
> VLAN > Port-based VLAN (Page 225)".
● Protocol-based VLAN
Each port of a device is assigned a protocol group. You configure protocol-based VLAN
in "Layer 2 > VLAN > Protocol-based VLAN port (Page 228)".
● IPv4 Subnet-based VLAN
The IPv4 address of the device is assigned a VLAN ID. You configure subnet-based
VLAN in "Layer 2 > VLAN > lPv4 subnet-based VLAN (Page 230)".
processing the VLAN assignment
If more than one VLAN assignment is created on the device, the assignments are processed
in the following order:
1. IPv4 subnet-based VLAN
2. Protocol-based VLAN
3. Port-based VLAN
The frame is first examined for the IPv4 address. If a rule on the "lPv4 subnet-based VLAN"
tab applies, the frame is sent to the corresponding VLAN. If no rule applies, the protocol type
of the frame is examined. If a rule on the "Protocol-based VLAN port" tab applies, the frame
is sent to the corresponding VLAN. If no rule applies, the frame is sent via the port-based
VLAN. The rules for the port-based VLAN are specified on the "Port-based VLAN" tab.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
33
Technical basics
4.2 VLAN
4.2.1
VLAN tagging
Expansion of the Ethernet frames by four bytes
For CoS (Class of Service, frame priority) and VLAN (virtual network), the IEEE 802.1 Q
standard defined the expansion of Ethernet frames by adding the VLAN tag.
Note
The VLAN tag increases the permitted total length of the frame from 1518 to 1522 bytes.
With the IE switches, the standard frame size is at least 1536 bytes.
The end nodes on the networks must be checked to find out whether they can process this
length / this frame type. If this is not the case, only frames of the standard length may be
sent to these nodes.
The additional 4 bytes are located in the header of the Ethernet frame between the source
address and the Ethernet type / length field:
Figure 4-1
Structure of the expanded Ethernet frame
The additional bytes contain the tag protocol identifier (TPID) and the tag control information
(TCI).
Tag protocol identifier (TPID)
The first 2 bytes form the Tag Protocol Identifier (TPID) and always have the value 0x8100.
This value specifies that the data packet contains VLAN information or priority information.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
34
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.2 VLAN
Tag Control Information (TCI)
The 2 bytes of the Tag Control Information (TCI) contain the following information:
CoS prioritization
The tagged frame has 3 bits for the priority that is also known as Class of Service (CoS). The
priority according to IEEE 802.1p is as follows:
CoS bits
Type of data
000
Non time-critical data traffic (less then best effort [basic setting])
001
Normal data traffic (best effort [background])
010
Reserved (standard)
011
Reserved ( excellent effort )
100
Data transfer with max. 100 ms delay
101
Guaranteed service, interactive multimedia
110
Guaranteed service, interactive voice transmission
111
Reserved
The prioritization of the data packets is possible only if there is a queue in the components in
which they can buffer data packets with lower priority.
The device has multiple parallel queues in which the frames with different priorities can be
processed. First, the frames with the highest priority ("Strict Priority" method) are processed.
This method ensures that the frames with the highest priority are sent even if there is heavy
data traffic.
Canonical Format Identifier (CFI)
The CFI is required for compatibility between Ethernet and the token Ring.
The values have the following meaning:
Value
Meaning
0
The format of the MAC address is canonical. In the canonical representation of the MAC
address, the least significant bit is transferred first. Standard-setting for Ethernet switches.
1
The format of the MAC address is not canonical.
VLAN ID
In the 12-bit data field, up to 4096 VLAN IDs can be formed. The following conventions
apply:
VLAN ID
Meaning
0
The frame contains only priority information (priority tagged frames) and no valid
VLAN identifier.
1 - 4094
Valid VLAN identifier, the frame is assigned to a VLAN and can also include priority information.
4095
Reserved
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
35
Technical basics
4.3 SNMP
4.3
SNMP
Introduction
With the aid of the Simple Network Management Protocol (SNMP), you monitor and control
network components from a central station, for example routers or switches. SNMP controls
the communication between the monitored devices and the monitoring station.
Tasks of SNMP:
● Monitoring of network components
● Remote control and remote parameter assignment of network components
● Error detection and error notification
In versions v1 and v2c, SNMP has no security mechanisms. Each user in the network can
access data and also change parameter assignments using suitable software.
For the simple control of access rights without security aspects, community strings are used.
The community string is transferred along with the query. If the community string is correct,
the SNMP agent responds and sends the requested data. If the community string is not
correct, the SNMP agent discards the query. Define different community strings for read and
write permissions. The community strings are transferred in plain text.
Standard values of the community strings:
● public
has only read permissions
● private
has read and write permissions
Note
Because the SNMP community strings are used for access protection, do not use the
standard values "public" or "private". Change these values following the initial
commissioning.
Further simple protection mechanisms at the device level:
● Allowed Host
The IP addresses of the monitoring systems are known to the monitored system.
● Read Only
If you assign "Read Only" to a monitored device, monitoring stations can only read out
data but cannot modify it.
SNMP data packets are not encrypted and can easily be read by others.
The central station is also known as the management station. An SNMP agent is installed on
the devices to be monitored with which the management station exchanges data.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
36
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.3 SNMP
The management station sends data packets of the following type:
● GET
Request for a data record from the agent
● GETNEXT
Calls up the next data record.
● GETBULK (available as of SNMPv2)
Requests multiple data records at one time, for example several rows of a table.
● SET
Contains parameter assignment data for the relevant device.
The SNMP agent sends data packets of the following type:
● RESPONSE
The agent returns the data requested by the manager.
● TRAP
If a certain event occurs, the SNMP agent itself sends traps.
SNMPv1/v2/v3 use UDP (User Datagram Protocol) and use the UDP ports 161 and 162. The
data is described in a Management Information Base (MIB).
SNMPv3
Compared with the previous versions SNMPv1 and SNMPv2. SNMPv3 introduces an
extensive security concept.
SNMPv3 supports:
● Fully encrypted user authentication
● Encryption of the entire data traffic
● Access control of the MIB objects at the user/group level
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
37
Technical basics
4.4 Routing function
4.4
Routing function
Introduction
The term routing describes the specification of routes for communication between different
networks; in other words, how does a data packet from subnet A get to subnet B.
SCALANCE X supports the following routing functions:
● Static routing
With static routing, the routes are entered manually in the routing table.
● Router redundancy
With standardized VRRP (Virtual Router Redundancy Protocol), the availability of
important gateways is increased by redundant routers.
– VRRPv2 (IPv4)
– VRRPv3 (IPv4 / IPv6)
● Dynamic routing
The entries in the routing table are dynamic and are updated continuously. The entries
are created with one of the following dynamic routing protocols:
– OSPFv2 (IPv4)
– OSPFv3 (IPv6)
– RIPv2 (IPv4)
– RIPng (IPv6)
4.4.1
Static routing
The route is entered manually in the routing table. Enter the route in the routing table on the
following pages.
● Layer 3 (IPv4) > Static Routes
● Layer 3 (IPv6) > Static Routes
See also
Static Routes (Page 300)
SCALANCE XM-400/XR-500 Web Based Management (WBM)
38
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.4 Routing function
4.4.2
VRRP
4.4.2.1
VRRPv2
Router redundancy with VRRP
With the Virtual Router Redundancy Protocol (VRRP), the failure of a router in a network can
be countered.
VRRP can only be used with virtual IP interfaces (VLAN interfaces) and not with router ports.
Several VRRP routers in a network segment are put together as a logical group representing
a virtual router (VR). The group is defined using the virtual ID (VRID). Within the group, the
VRID must be the same. The VRID can no longer be used for other groups.
The virtual router is assigned a virtual IP address and a virtual MAC address. One of the
VRRP routers within the group is specified as the master router. The master router has
priority 255. The other VRRP routers are backup routers. The master router assigns the
virtual IP address and the virtual MAC address to its network interface. The master router
sends VRRP packets (advertisements) to the backup routers at specific intervals. With the
VRRP packets, the master router signals that it is still functioning. The master router also
replies to the ARP queries.
If the virtual master router fails, a backup router takes over the role of the master router. The
backup router with the highest priority becomes the master router. If the priority of the
backup routers is the same, the higher MAC address decides. The backup router becomes
the new virtual master router.
The new virtual master router adopts the virtual MAC and IP address. This means that no
routing tables or ARP tables need to be updated. The consequences of a device failure are
therefore minimized.
You configure VRRP in "Layer 3 (IPv4) > VRRP (Page 311)".
4.4.2.2
VRRP3
Version 3 of VRRP is based on version 2.
Note
• Enable routing to be able to use VRRPv3.
• You can only use VRRPv3 in conjunction with VLAN interfaces. Router ports are not
supported.
• Simultaneous operation of VRRP and VRRPv3 is not possible.
• VRRPv3 supports IPv4 and IPv6. Both can be configured and operated at the same time
with VRRP3.
You configure VRRPv3 in:
IPv4: Layer 3 (IPv4 )> VRRPv3 (Page 317)
IPv6: Layer 3 (IPv6 )> VRRPv3 (Page 358)
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
39
Technical basics
4.4 Routing function
4.4.3
OSPF
4.4.3.1
OSPFv2
Dynamic routing with OSPFv2
OSPF (Open Shortest Path First) is a cost-based routing protocol. To calculate the shortest
and most cost-effective route, the Short Path First algorithm by Dijkstra is used. OSPF was
developed by the IETF (Internet Engineering Task Force).
You configure OSPFv2 in "Layer 3 (IPv4) > OSPFv2 (Page 324)".
OSPFv2 divides an autonomous system (AS) into different areas.
Areas in OSPF
The following areas exist:
● Backbone
The backbone area is area 0.0.0.0. All other areas are connected to this area. The
backbone area is connected either directly or via virtual connections with other areas.
All routing information is available in the backbone area. As a result, the backbone area is
responsible for forwarding information between different areas.
● Stub Area
This area contains the routes within its area within the autonomous system and the
standard route out of the autonomous system. The destinations outside this autonomous
system are assigned to the standard route.
● Totally Stubby Area
This area knows only the routes within its area and the standard route out of the area.
● Not So Stubby Area (NSSA)
This area can forward (redistribute) packets from other autonomous systems into the
areas of its own autonomous system. The packets are further distributed by the NSSA
router.
Routers of OSPF
OSPF distinguishes the following router types:
● Internal router (IR)
All OSPF interfaces of the router are assigned to the same area.
● Area Border Router (ABR)
The OSPF interfaces of the router are assigned to different areas. One OSPF interface is
assigned to the backbone area. Where possible, routes are grouped together.
● Backbone Router (BR)
At least one of the OSPF interfaces is assigned to the backbone area.
● Autonomous System Border Router (ASBR)
One interface of the router is connected to a different AS, for example an AS that uses
the routing protocol RIP.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
40
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.4 Routing function
Virtual connection
Each area must be connected to the backbone area. In some situations a direct physical
connection is not possible. In this case, a router of the relevant area must be connected to a
backbone router via a virtual connection.
LSA types
Within the autonomous system, packets are exchanged that contain information about the
connections of a router and the connection status message. The packets are also known as
LSAs (Link State Advertisements). The LSAs are always sent from the router to the neighbor
router.
If there are changes in the network, LSAs are sent to all routers in the network. The
information depends on the LSA type.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
41
Technical basics
4.4 Routing function
Router LSA (LSA Type 1)
The LSA Type 1 is only sent within an area. For each active connection of the router
that belongs to the area in consideration, an LSA Type 1 is generated. The LSA Type
1 contains information about the status and the costs of the connection, for example IP
address, network mask, network type
Network LSA (LSA Type 2)
The LSA Type 2 is sent only within an area. For each network that belongs to the relevant area, the router generates an LSA Type 2. If several routers are interconnected in
a network, the LSA Type 2 is sent by the designated router (DR). The LSA Type 2
includes the network address, the network mask and a list of routers that are connected to the network
Summary LSA (LSA Type 3 / LSA Type 4)
The Summary LSA is generated by the area border router and sent into the area. The
Summary LSA contains information about routes outside the area but inside the AS.
Where possible, the routes are grouped together.
• Summary LSA (LSA Type 3)
The LSA Type 3 describes the routes to the networks and advertises the standard
route to the areas.
• AS Summary LSA (LSA Type 4)
The LSA Type 4 describes the routes to the ASBR.
External LSA (LSA Type 5 / LSA Type 7)
The External LSA is generated by the ASBR. The LSA type depends on the area.
• AS External LSA (LSA Type 5)
The LSA Type 5 is sent by the AS border router into the areas of the autonomous
system except the Stub and NSSA areas. The LSA contains information about
routes to a network in another AS. The routes are either created manually or
learned externally. The ASBR uses LSA Type 5 to distribute standard routes to the
backbone area.
• NSSA External LSA (LSA Type 7)
The LSA Type 7 is generated by the AS border router of an NSSA. The router is
also known as the NSSA ASBR. The LSA Type 7 is sent only within the NSSA. If
the P bit in LSA Type 7 = 1, these LSAs are converted to LSA Type 5 by the ABR
and sent to the backbone area.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
42
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.4 Routing function
Establishing the neighborhood
The router runs through the following statuses to establish a connection to the neighbor
router.
1. Attempt state / Init state
The router activates OSPF and begins to send and receive Hello packets. Based on the
received Hello packets, the router learns which OSPF routers are in its vicinity. The router
checks the content of the Hello packet. The Hello packet also contains the list of the
neighbor routers (neighbor table) of the "sender".
2. Two way state
If, for example, the ID of the area, the area type and the settings for the times match, a
connection (adjacency) can be established to the neighbor. In a point-to-point network,
the connection is established directly. If several neighbor routers can be reached in a
network, the designated router (DR) and the designated backup router (DBR) are
identified based on Hello packets. The router with the highest router priority becomes the
designated router. If two routers have the same router priority, the router with the highest
router ID becomes the designated router. The router establishes a connection to the
designated router.
3. Exchangestart state
The neighbor routers decide which router starts communication. The router with the
higher router ID becomes the designated router.
4. Exchange state
The neighbor routers send packets that describe the content of their neighborhood
database. The neighborhood database (link state database - LSDB) contains information
on the topology of the network.
5. Loading state
The router completes the received information. If the router still has questions relating to
the status of a specific connection, it sends a link state request. The neighbor router
sends a response (link state update). The response contains a suitable LSA. The router
confirms receipt of the response (link state acknowledge).
6. Full State
The information exchange with the neighbor router is completed. The neighborhood
database of the neighbor router is the same. Based on the Short Path First algorithm, the
router calculates a route to every destination. The route is entered in the routing table.
Check the neighborhood
The Hello packets are only used to establish the neighborhood relations. Hello packets are
used to check the connection to the neighbor router by sending them cyclically. If no Hello
packet is received within a certain interval (dead interval), the connection to the neighbor is
marked as "down". The relevant entries are deleted.
Updating the neighborhood database
Once the neighborhood database is established, LSAs are sent to all routers in the network if
there are changes in the topology.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
43
Technical basics
4.4 Routing function
4.4.3.2
OSPFv3
Version 3 of OSPF is based on version 2 and is only used with IPv6. A large part of the
routing mechanisms was adopted. OSPFv3 is defined in the RFCs 2740 and 5340.
You configure OSPFv2 in "Layer 3 (IPv6) > OSPFv3".
The following has not changed:
● The statuses that a router runs through to establish a connection to the neighbor router.
● The areas : Backbone, Stub Area, Totally Stubby Area, Not So Stubby Area (NSSA)
● The router types: Internal Router (IR), Area Border Router (ABR), Backbone Router (BR),
Autonomous System Area Border Router (ASBR), Designated Router (DR)
● The router ID, the area ID and the ID of the LSA are entered in the IPv4 address format:
x.x.x.x
What has changed?
Terms
The terms network or subnet are replaced by link.
Authentication
The authentication was removed. Instead OSPFv3 uses IPsec, that is implemented in IPv6.
Neighbor routers
The neighbor routers are identified via the router ID.
Neighbor database
The neighbor database (link state database - LSDB) is divided into different areas of
application:
● Link scope LSDB
Contains the link LSA
● Area scope LSDB
contains the following LSAs
– Router LSA
– Network LSA
– Inter-area prefix LSA
– Inter area router LSA
– Intra area prefix LSA
● AS scope LSDB
Contains the AS external LSA
SCALANCE XM-400/XR-500 Web Based Management (WBM)
44
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.4 Routing function
LSA types
Two new LSA types were defined for OSPFv3.
OSPFv2
OSPFv3
Who
Within
Description
1 Router LSA
0x2001
Router
LSA
every
router
Area
No longer contains address information. This is contained in
the new LSA type 2009.
2 Network LSA
0x2002
Network
LSA
DR
Area
No longer contains address information. This is contained in
the new LSA type 2009.
3 Summary
LSA
0x2003
Inter-area ABR
prefix LSA
Area
Same function as in OSPFv2, simply renamed
4 AS Summary
LSA
0x2004
Inter-Area
Router
LSA
ABR
Area
Same function as in OSPFv2, simply renamed
5 AS External
LSA
0x4005
AS External LSA
ASBR
AS
Same function as in OSPFv2, simply renamed
7 NSSA External LSA
0x2007
Type 7
LSA
NSSA
ASBR
NSSA
Same function as in OSPFv2, simply renamed
0x2008
Link LSA
every
router
Link
The LSA is sent by the router to every router linked to it.
The LSA contains the link local address of the router and a
list with IPv6 prefixes configured on the link.
0x2009
Intra area every
prefix LSA router
Area
The LSA is sent only within an area. The LSA contains the
IPv6 prefixes connected to the router or network.
In contrast to OSPFv2, OSPFv3 can forward unknown LSA types. Previously these were
deleted and not distributed further.
4.4.4
RIP
4.4.4.1
RIPv2
Dynamic routing with RIPv2
The Routing Information Protocol (RIPv2) is used to create routing tables automatically.
RIPv2 is used in autonomous systems (AS) with a maximum of 15 routers. It is based on the
Distance-Vector algorithm.
RIPv2 was developed by the IETF (Internet Engineering Task Force) and is described in
RFC 2453.
You configure RIPv2 in "Layer 3 (IPv4) > RIPv2".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
45
Technical basics
4.4 Routing function
Setting up a routing table
Since a router initially only knows its directly connected networks, it sends a request to its
direct neighbor routers. As the reply, it receives the routing tables of the neighbor routers.
Based on the information it receives, the router set up its own routing table.
The routing table contains entries for all possible destinations. Each entry includes the
distance to the destination and the first router on the route.
The distance is also known as the metric. This indicates the number of routers to be passed
through on the route to the destination (hop count). The maximum distance is 15 routers
(hops).
Updating the routing table
Once the routing table is set up, the router sends its routing table to each direct neighbor
router via the UDP port 520 at intervals of 30 seconds.
The router compares new routing information with its existing routing table. If the new
information includes shorter routes, the existing routes are overwritten. The router only
keeps the shortest route to a destination.
Checking neighbor routers
If a router does not receive messages from a neighbor router for longer than 180 seconds, it
marks the router as being invalid. The router assigns the metric 16 for the neighbor router.
4.4.4.2
RIPng
RIPng (RIP next generation) is only used with IPv6 and is defined in RFC 2080. As with RIP
(IPv4), RIPng is based on the distance vector algorithm of Bellman-Ford.
In contrast to RIPv2, RIPng is activated directly on the layer 3 interface (VLAN interface /
router port) and not globally on the device.
RIPng uses the UDP port 521 and RIP the UDP port 520.
You configure RIPng in "Layer 3 (IPv6) > RIPng".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
46
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.5 Redundancy mechanism
4.5
Redundancy mechanism
4.5.1
Spanning Tree
Avoiding loops on redundant connections
The spanning tree algorithm allows network structures to be created in which there are
several connections between two stations. Spanning tree prevents loops being formed in the
network by allowing only one path and disabling the other (redundant) ports for data traffic. If
there is an interruption, the data can be sent over an alternative path. The functionality of the
spanning tree algorithm is based on the exchange of configuration and topology change
frames.
Definition of the network topology using the configuration frames
The devices exchange configuration frames known as BPDUs (Bridge Protocol Data Units)
with each other to calculate the topology. The root bridge is selected and the network
topology created using these frames. BPDUs also bring about the status change of the root
ports.
The root bridge is the bridge that controls the spanning tree algorithm for all involved
components.
Once the root bridge has been specified, each device sets a root port. The root port is the
port with the lowest path costs to the root bridge.
Response to changes in the network topology
If nodes are added to a network or drop out of the network, this can affect the optimum path
selection for data packets. To be able to respond to such changes, the root bridge sends
configuration messages at regular intervals. The interval between two configuration
messages can be set with the "Hello Time" parameter.
Keeping configuration information up to date
With the "Max Age" parameter, you set the maximum age of configuration information. If a
bridge has information that is older than the time set in Max Age, it discards the message
and initiates recalculation of the paths.
New configuration data is not used immediately by a bridge but only after the period
specified in the "Forward Delay" parameter. This ensures that operation is only started with
the new topology after all the bridges have the required information.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
47
Technical basics
4.5 Redundancy mechanism
4.5.1.1
RSTP, MSTP, CIST
Rapid Spanning Tree Protocol (RSTP)
One disadvantage of STP is that if there is a disruption or a device fails, the network needs
to reconfigure itself: The devices start to negotiate new paths only when the interruption
occurs. This can take up to 30 seconds. Fur this reason, STP was expanded to create the
"Rapid Spanning Tree Protocol" (RSTP, IEEE 802.1w). This differs from STP essentially in
that the devices are already collecting information about alternative routes during normal
operation and do not need to gather this information after a disruption has occurred. This
means that the reconfiguration time for an RSTP controlled network can be reduced to a few
seconds.
This is achieved by using the following functions:
● Edge ports (end node port)
Edge ports are ports connected to an end device.
A port that is defined as an edge port is activated immediately after connection
establishment. If a spanning tree BPDU is received at an edge port, the port loses its role
as edge port and it takes part in (R)STP again. If no further BPDU is received after a
certain time has elapsed (3 x hello time), the port returns to the edge port status.
● Point-to-point (direct communication between two neighboring devices)
By directly linking the devices, a status change (reconfiguration of the ports) can be made
without any delays.
● Alternate port (substitute for the root port)
A substitute for the root port is configured. If the connection to the root bridge is lost, the
device can establish a connection over the alternate port without any delay due to
reconfiguration.
● Reaction to events
Rapid spanning tree reacts to events, for example an aborted connection, without delay.
There is no waiting for timers as in spanning tree.
● Counter for the maximum bridge hops
The number of bridge hops a package is allowed to make before it automatically
becomes invalid.
In principle, therefore with rapid spanning tree, alternatives for many parameters are
preconfigured and certain properties of the network structure taken into account to reduce
the reconfiguration time.
Multiple Spanning Tree Protocol (MSTP)
The Multiple Spanning Tree Protocol (MSTP) is a further development of the Rapid
Spanning Tree Protocol. Among other things, it provides the option of operating several
RSTP instances within different VLANs or VLAN groups and, for example, making paths
available within the individual VLANs that the single Rapid Spanning Tree Protocol would
globally block.
Note
Default setting
HTTP is enabled as default on the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
48
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.5 Redundancy mechanism
Common and internal Spanning Tree (CIST)
CIST identifies the internal instance used by the switch that is comparable in principle with
an internal RSTP instance.
4.5.2
HRP
HRP - High Speed Redundancy Protocol
HRP is the name of a redundancy method for networks with a ring topology. The switches
are interconnected via ring ports. One of the switches is configured as the redundancy
manager (RM). The other switches are redundancy clients. Using test frames, the
redundancy manager checks the ring to make sure it is not interrupted. The redundancy
manager sends test frames via the ring ports and checks that they are received at the other
ring port. The redundancy clients forward the test frames.
If the test frames of the RM no longer arrive at the other ring port due to an interruption, the
RM switches through its two ring ports and informs the redundancy clients of the change
immediately. The reconfiguration time after an interruption of the ring is a maximum of 0.3
seconds.
Standby redundancy
Standby redundancy is a method with which rings each of which is protected by high-speed
redundancy can be linked together redundantly. In the ring, a master/slave device pair is
configured and these monitor each other via their ring ports. If a fault occurs, the data traffic
is redirected from one Ethernet connection (standby port of the master or standby server) to
another Ethernet connection (standby port of the slave).
Requirements
● HRP is supported in ring topologies with up to 50 devices. Exceeding this number of
devices can lead to a loss of data traffic.
● For HRP, only devices that support this function can be used in the ring.
● All devices must be interconnected via their ring ports.
● Devices that do not support HRP must be linked to the ring using special devices with
HRP capability. Up to the ring, this connection is not redundant.
4.5.3
MRP
4.5.3.1
MRP - Media Redundancy Protocol
The "MRP" method conforms to the Media Redundancy Protocol (MRP) specified in the
following standard:
IEC 62439-2 Edition 1.0 (2010-02) Industrial communication networks - High availability
automation networks Part 2: Media Redundancy Protocol (MRP)
The reconfiguration time after an interruption of the ring is a maximum of 0.2 seconds.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
49
Technical basics
4.5 Redundancy mechanism
Requirements
Requirements for problem-free operation with the MRP media redundancy protocol are as
follows:
● MRP is supported in ring topologies with up to 50 devices.
Except in PROFINET IO systems, topologies with up to 100 SCALANCE X-200 and
SCALANCE X-300 IE switches were tested successfully.
Exceeding this number of devices can lead to a loss of data traffic.
● The ring in which you want to use MRP may only consist of devices that support this
function.
These include, for example, some of the Industrial Ethernet SCALANCE X switches,
some of the communications processors (CPs) for SIMATIC S7 and PG/PC or nonSiemens devices that support this function.
● All devices must be interconnected via their ring ports.
Multimode connections up to 3 km and single mode connections up to 26 km between
two SCALANCE X IE switches are possible. At greater distances, the specified
reconfiguration time may be longer.
● "MRP" must be activated on all devices in the ring (see section "Configuration in STEP 7
(Page 53)").
● The connection settings (transmission medium / duplex) must be set to full duplex and at
least 100 Mbps for all ring ports. Otherwise there may be a loss of data traffic.
– STEP 7: Set all the ports involved in the ring to "Automatic settings" in the "Options"
tab of the properties dialog.
– WBM: If you configure with Web Based Management, the ring ports are set
automatically to autonegotiation.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
50
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.5 Redundancy mechanism
Topology
The following schematic shows a possible topology for devices in a ring with MRP.
Figure 4-2
Example of a ring topology with the MRP media redundancy protocol
The following rules apply to a ring topology with media redundancy using MRP:
● All the devices connected within the ring topology are members of the same redundancy
domain.
● One device in the ring is acting as redundancy manager.
● All other devices in the ring are redundancy clients.
Non MRP-compliant devices can be connected to the ring via a SCALANCE X switch or via
a PC with a CP 1616.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
51
Technical basics
4.5 Redundancy mechanism
4.5.3.2
Configuration in WBM
Role
The choice of role depends on the following use cases:
● You want to use MRP in a ring topology only with Siemens devices:
– For at least one device in the ring select "Automatic Redundancy Detection" or "MRP
Auto Manager".
– For all other devices in the ring select "MRP Client" or "Automatic Redundancy
Detection".
● You want to use MRP in a ring topology that also includes non-Siemens devices:
– For exactly one device in the ring select the role "MRP Auto Manager".
– For all other devices in the ring topology, select the role of "MRP Client".
Note
The use of "Automatic Redundancy Detection" is not possible when using non-Siemens
devices.
● You configure the devices in an MRP ring topology partly with WBM and partly with STEP
7:
– With the devices you configure using WBM, select "MRP Client" for all devices.
– With the devices that you configure using STEP 7, select precisely one device as
"Manager" or "Manager (Auto)" and "MRP Client" for all other devices.
Note
If a device is assigned the role of "Manager" with STEP 7, all other devices in the ring
must be assigned the "MRP Client" role. If there is a device with the "Manager" role and a
device with the "Manager (Auto)"/"MRP Auto-Manager" in a ring, this can lead to
circulating frames and therefore to failure of the network.
Configuration
In WBM, you configure MRP on the following pages:
● Configuration (Page 209)
● Ring (Page 242)
SCALANCE XM-400/XR-500 Web Based Management (WBM)
52
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.5 Redundancy mechanism
4.5.3.3
Configuration in STEP 7
Configuration in STEP 7
To create the configuration in STEP 7, select the parameter group "Media redundancy" on
the PROFINET interface.
Set the following parameters for the MRP configuration of the device:
● Domain
● Role
● Ring port
● Diagnostic interrupts
These settings are described below.
Note
Valid MRP configuration
In the MRP configuration in STEP 7, make sure that all devices in the ring have a valid MRP
configuration before you close the ring. Otherwise, there may be circulating frames that will
cause a failure in the network.
One device in the ring needs to be configured as "redundancy manager and all other devices
in the ring as "clients".
Note
Changing the role
If you want to change the MRP role, first open the ring.
Note
Starting up and restarting
The MRP settings remain in effect following a restart of the device or following a power down
and hot restart.
Note
Prioritized startup
If you configure MRP in a ring, you cannot use the "prioritized startup" function in PROFINET
applications on the devices involved.
If you want to use the "prioritized startup" function, then disable MRP in the configuration.
In the STEP 7 configuration, set the role of the relevant device to "Not a node in the ring".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
53
Technical basics
4.5 Redundancy mechanism
Domain
Single MRP rings
If you want to configure a single MRP ring, leave the factory setting "mrpdomain 1" in the
"Domain" drop-down list.
All devices configured in a ring with MRP must belong to the same redundancy domain. A
device cannot belong to more than one redundancy domain.
If you leave the setting for "Domain" as the factory set "mrpdomain-1", the defaults for "Role"
and "Ring ports" also remain active.
MRP multiple rings
If you configure multiple MRP rings, the nodes of the ring will be assigned to the individual
rings with the "Domain" parameter.
Set the same domain for all devices within a ring. Set different domains for different rings.
Devices that do not belong to the same ring must have different domains.
Role
The choice of role depends on the following use cases.
● You want to use MRP in a topology with one ring only with Siemens devices and without
monitoring diagnostic interrupts:
Assign all devices to the "mrpdomain-1" domain and the role "Manager (Auto)".
The device that actually takes over the role of redundancy manager, is negotiated by
Siemens devices automatically.
● You want to use MRP in a topology with multiple rings only with Siemens devices and
without monitoring diagnostic interrupts (MRP multiple rings):
– Assign the device that connects the rings the role of "Manager".
– For all other devices in the ring topology, select the role of "Client".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
54
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.5 Redundancy mechanism
● You want to use MRP in a ring topology that also includes non-Siemens devices or you
want to receive diagnostic interrupts relating to the MRP status from a device (see
"Diagnostic interrupts"):
– Assign precisely one device in the ring the role of "Manager (Auto)".
– For all other devices in the ring topology, select the role of "Client".
● You want to disable MRP:
Select the option "Not node in the ring" if you do not want to operate the device within a
ring topology with MRP.
Note
Role after resetting to factory settings
With brand new Siemens devices and those reset to the factory settings the following
MRP role is set:
• CPs:
"Manager (Auto)"
• SCALANCE X-200, SCALANCE XB-200 (PROFINET variants), SCALANCE X-300
and SCALANCE X-400:
"Automatic Redundancy Detection"
If you are operating a non-Siemens device as the redundancy manager in the ring, this
may cause loss of the data traffic.
With brand new SCALANCE XB-200 (EtherNet/IP variants), SCALANCE XM-400 and
SCALANCE XR-500 IE switches and those set to the factory settings, MRP is disabled
and spanning tree enabled.
Ring port 1 / ring port 2
Here, select the port you want to configure as ring port 1 and ring port 2.
With devices with more than 8 ports, not all ports can be selected as ring port.
The drop-down list shows the selection of possible ports for each device type. If the ports are
specified in the factory, the boxes are grayed out.
NOTICE
Ring ports after resetting to factory settings
If you reset to the factory settings, the ring port settings are also reset.
If other ports were used previously as ring ports before resetting, with the appropriate
attachment, a previously correctly configured device can cause circulating frames and
therefore the failure of the data traffic.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
55
Technical basics
4.5 Redundancy mechanism
Diagnostic interrupts
Enable the "Diagnostic interrupts" option, if you want diagnostic interrupts relating to the
MRP status on the local CPU to be output.
The following diagnostic interrupts can be generated:
● Wiring or port error
Diagnostic interrupts are generated if the following errors occur at the ring ports:
– Connection abort on a ring port
– A neighbor of the ring port does not support MRP.
– A ring port is connected to a non-ring port.
– A ring port is connected to the ring port of another MRP domain.
● Status change active/passive (redundancy manager only)
If the status changes (active/passive) in a ring, a diagnostics interrupt is generated.
Parameter assignment of the redundancy is not set by STEP 7 (redundancy alternatives)
This option only affects switches. Select this option if you want to set the properties for
media redundancy using alternative mechanism or tools such as Web based Management
(WBM), CLI or SNMP.
If you enable this option, existing redundancy settings from WBM, CLI or SNMP, are retained
and are not overwritten. The parameters in the "MRP configuration" box are then reset and
grayed out. The entries then have no meaning.
4.5.4
Standby
General
SCALANCE X switches support not only ring redundancy within a ring but also redundant
linking of rings or open network segments (linear bus). In the redundant link, rings are
connected together over Ethernet connections. This is achieved by configuring a
master/slave device pair in one ring so that the devices monitor each other and, in the event
of a fault, redirect the data traffic from the normally used master Ethernet connection to the
substitute (slave) Ethernet connection.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
56
Configuration Manual, 11/2015, C79000-G8976-C248-10
Technical basics
4.5 Redundancy mechanism
Standby redundancy
Figure 4-3
Example of a redundant link between rings
For a redundant link as shown in the figure, two devices must be configured as standby
redundancy switches within a network segment. In this case, network segments are rings
with a redundancy manager. Instead of rings, network segments might also be linear.
The two standby redundancy switches connected in the configuration exchange data frames
with each other to synchronize their operating statuses (one device is master and the other
slave). If there are no problems, only the link from the master to the other network segment
is active. If this link fails (for example due to a link-down or a device failure), the slave
activates its link as long as the problem persists.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
57
Technical basics
4.6 Link aggregation
4.6
Link aggregation
Link aggregation
With link aggregation, several parallel physical connections with the same transmission
speed are grouped together to form a logical connection with a higher transmission speed.
This method based on IEEE 802.3ad is also known as port trunking or channel bundling.
Link aggregation works only with full duplex connections with the same transmission speed
in point-to-point mode. This achieves multiplication of the bandwidth or transmission speed.
If part of the connection fails, the data traffic is handled via the remaining parts of the
connection.
To control and monitor, the Link Aggregation Control Layer (LACL) and the Link Aggregation
Control Protocol (LACP) are used.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
58
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.1
5
Web Based Management
How it works
The device has an integrated HTTP server for Web Based Management (WBM). If a device
is addressed using an Internet browser, it returns HTML pages to the client PC depending on
the user input.
The user enters the configuration data in the HTML pages sent by the device. The device
evaluates this information and generates reply pages dynamically.
The advantage of this method is that only an Internet browser is required on the client.
Note
Secure connection
WBM also allows you to establish a secure connection via HTTPS.
Use HTTPS for protected transfer of your data. If you wish to access WBM only via a secure
connection, activate the option "HTTPS Server only" under "System > Configuration".
Requirements
WBM display
● The device has an IP address
● There is a connection between the device and the client PC. With the Windows ping
command, you can check whether or not a connection exists.
● Access using HTTPS is enabled.
● JavaScript is activated in the Internet browser.
● The Internet browser must not be set so that it reloads the page from the server each
time the page is accessed. The updating of the dynamic content of the page is ensured
by other mechanisms. In the Internet Explorer, you can make the appropriate setting in
the "Options > Internet Options > General" menu in the section "Browsing history" with
the "Settings" button. Under "Check for newer versions of stored pages:", select
"Automatically".
● If a firewall is used, the relevant ports must be opened.
– For access using HTTP: TCP port 80
– For access using HTTPS: TCP port 443
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
59
Configuring with Web Based Management
5.1 Web Based Management
The display of the WBM was tested with the following desktop Internet browsers:
● Microsoft Internet Explorer 11
● Mozilla Firefox 38 ESR
● Chrome V43
Note
Compatibility view
In Microsoft Internet Explorer, disable the compatibility view to ensure correct display and to
allow problem-free configuration using WBM.
Display of the WBM on mobile devices
For mobile devices, the following minimum requirements must be met:
Resolution
960 x 640 pixels
Operating system
Internet browser
Android as of version 4.2.1
Chrome as of version 18 on Android
iOS as of version 6.0.2
Safari as of version 6 on iOS
Tested with the following Internet browsers for mobile devices:
● Safari as of version 8 on iOS as of version 8.1.3 (iPad Mini Model A1432)
● Chrome as of version 40 on Android as of version 5.0.2 (Nexus 7C Asus)
● Firefox as of version 35 on as of version 5.0.2
Note
Display of the WBM and working with it on mobile devices
The display on the WBM pages and how you work with them on mobile devices may differ
compared with the same pages on desktop devices. Some pages also have an optimized
display for mobile devices.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
60
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.2 Login
5.2
Login
Establishing a connection to a device
Follow the steps below to establish a connection to a device using an Internet browser:
1. There is a connection between the device and the client PC. With the ping command, you
can check whether or not a connection exists.
2. In the address box of the Internet browser, enter the IP address or the URL of the device.
If there is a problem-free connection to the device, the logon page of Web Based
Management (WBM)is displayed.
Logging on using the Internet browser
Selecting the language of the WBM
1. From the drop-down list at the top right, select the language version of the WBM pages.
2. Click the "Go" button to change to the selected language.
Note
Available languages
As of version 5.0 English and German are available. Other languages will follow in a later
version.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
61
Configuring with Web Based Management
5.2 Login
Logon with HTTP
There are two ways in which you can log on via HTTP. You either use the logon option in the
center of the browser window or the logon option in the upper left area of the browser
window.
The following steps apply when logging on, whichever of the above options you choose:
1. Enter the following in the "Name" input box:
– "admin": With this user type, you can change the settings of the device (read and write
access to the configuration data).
– "user": With this user type, you cannot change any of the settings of the device (read
access to the configuration data).
2. Enter your password in the "Password" input box.
When you log in for the first time or following a "Restore Factory Defaults and Restart",
enter the standard password in the "Password" input box.
– "admin": Standard password "admin"
– "user": Standard password "user"
3. Click the "Login" button or confirm your entry with "Enter".
When you log on for the first time or following a "Restore Factory Defaults and Restart",
with the default user "admin" you will be prompted to change the password.
The new password must meet the following password policies:
– Password length: at least 8 characters, maximum 128 characters.
– at least 1 uppercase letter
– at least 1 special character
– at least 1 number
You need to repeat the password as confirmation. The password entries must match.
Click the "Set Values" button to complete the action and activate the new password.
Once you have logged in successfully, the start page appears.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
62
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.2 Login
Logon with HTTPS
Web Based Management also allows you to connect to the device over the secure
connection of the HTTPS protocol. Follow these steps:
1. Click on the link "Switch to secure HTTP" on the login page or enter "https://" and the IP
address of the device in the address box of the Internet browser.
2. Check the displayed certificate warning and confirm it if applicable.
The logon page of Web Based Management appears.
3. Enter the following in the "Name" input box:
– "admin": With this user type, you can change the settings of the device (read and write
access to the configuration data).
– "user": With this user type, you cannot change any of the settings of the device (read
access to the configuration data).
4. Enter your password in the "Password" input box.
When you log in for the first time or following a "Restore Factory Defaults and Restart",
enter the standard password in the "Password" input box.
– "admin": Standard password "admin"
– "user": Standard password "user"
5. Click the "Login" button or confirm your entry with "Enter".
When you log on for the first time or following a "Restore Factory Defaults and Restart",
with the default user "admin" you will be prompted to change the password.
The new password must meet the following password policies:
– Password length: at least 8 characters, maximum 128 characters.
– at least 1 uppercase letter
– at least 1 special character
– at least 1 number
You need to repeat the password as confirmation. The password entries must match.
Click the "Set Values" button to complete the action and activate the new password.
Once you have logged in successfully, the start page appears.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
63
Configuring with Web Based Management
5.3 The "Information" menu
5.3
The "Information" menu
5.3.1
Start page
View of the Start page
When you enter the IP address of the device, the start page is displayed after a successful
login. You cannot configure anything on this page.
General layout of the WBM pages
The following areas are generally available on every WBM page:
● Selection area (1): Top area
● Display area (2): Top area
● Navigation area (3): Left-hand area
● Content area (4): Middle area
SCALANCE XM-400/XR-500 Web Based Management (WBM)
64
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Selection area (1)
The following is available in the selection area:
● Logo of Siemens AG
When you click on the logo, you arrive at the Internet page of the corresponding basic
device in Siemens Industry Online Support.
● Display of: "System Location / System Name"
– System location" contains the location of the device.
With the settings when the device ships, the in-band port IP address of the device is
displayed.
– "System Name" is the device name.
With the settings when the device ships, the device type is displayed.
You can change the content of this display with "System > General > Devices".
● Drop-down list for language selection
● System time and date
You can change the content of this display with "System > System Time.
Display area (2)
In the upper part of the display area, you can see the full title of the currently selected menu
item.
In the lower part of the display area, you will find the following:
● Print
If you click this button, a popup window opens. The popup window contains a view of the
page content optimized for printers.
Note
Printing larger tables
If you want to print large tables, please use the "Print preview" function of your Internet
browser.
● Help
When you click this button, the help page of the currently selected menu item is opened
in a new browser window.
The help page contains a description of the content area. Under certain circumstances,
options are described that are not available on the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
65
Configuring with Web Based Management
5.3 The "Information" menu
● LED simulation
Each component of a device has one or more LEDs that provide information on the
operating state of the device. Depending on its location, direct access to the device may
not always be possible. Web Based Management therefore displays simulated LEDs.
Unoccupied slots or unused connectors are displayed as gray LEDs. The meaning of the
LED displays is described in the operating instructions.
If you click the simulated "SELECT/SET" button, you can change the display mode (LEDs
DM or D1/D2).
If you click this button, you open the window for the LED simulation. You can show this
window during a change of menu and move it as necessary. To close the LED simulation,
click the "Close" button in the LED simulation window.
● Logging out
You can log out from any WBM page by clicking the "Logout" link.
Navigation area (3)
In the navigation area, you have various menus available. Click the individual menus to
display the submenus. The submenus contain pages on which information is available or
with which you can create configurations. These pages are always displayed in the content
area.
Content area (4)
The content area shows a graphic of the device. The graphic is dynamic. The basic device is
always shown. If extenders/media modules are connected to the basic device, these are also
shown.
Figure 5-1
Example of a device graphic: SCALANCE XM416-4C with one port extender PE408
SCALANCE XM-400/XR-500 Web Based Management (WBM)
66
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
The following is displayed below the device graphic:
● PNIO Name of Station
Shows the PROFINET IO device name.
● System Nam
Shows the name of the device.
● Device Type
Shows the type designation of the device.
● PNIO AR Status
Shows the PROFINET IO application relation status.
– Online
There is a connection to a PROFINET IO controller. The PROFINET IO controller has
downloaded its configuration data to the device. The device can send status data to
the PROFINET IO controller.
In this status, the parameters set by the PROFINET IO controller cannot be configured
on the device.
– Offline
There is no connection to the PROFINET IO controller.
● Power Supply 1 / Power Supply 2
– Up
Power supply 1 or 2 is applied
– Down:
Power supply 1 or 2 is not applied or is below the permitted voltage.
● PLUG Configuration
Shows the status of the configuration data on the PLUG, refer to the section "System >
PLUG > PLUG Configuration".
● PLUG License
Shows the status of the license on the PLUG, refer to the section "System >PLUG >
PLUG License".
● Fault Status
Shows the fault status of the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
67
Configuring with Web Based Management
5.3 The "Information" menu
Buttons you require often
The pages of the WBM contain the following standard buttons:
● Refresh the display with "Refresh"
Web Based Management pages that display current parameters have a "Refresh" button
at the lower edge of the page. Click this button to request up-to-date information from the
device for the current page.
Note
If you click the "Refresh" button, before you have transferred your configuration changes
to the device using the "Set Values" button, your changes will be deleted and the
previous configuration will be loaded from the device and displayed here.
● Save entries with "Set Values"
Pages in which you can make configuration settings have a "Set Values" button at the
lower edge. The button only becomes active if you change at least one value on the
page. Click this button to save the configuration data you have entered on the device.
Once you have saved, the button becomes inactive again.
Note
Changing configuration data is possible only with the "admin" role.
● Create entries with "Create"
Pages in which you can make new entries have a "Create" button at the lower edge. Click
this button to create a new entry.
● Delete entries with "Delete"
Pages in which you can delete entries have a "Delete" button at the lower edge. Click this
button to delete the previously selected entries from the device memory. Deleting also
results in an update of the page in the WBM.
● Page down with "Next"
On pages with a lot of data records the number of data records that can be displayed on
a page is limited. Click the "Next" button to page down through the data records.
● Page back with "Prev"
On pages with a lot of data records the number of data records that can be displayed on
a page is limited. Click the "Prev" button to page back through the data records.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
68
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.2
Versions
Versions of hardware and software
This page shows the versions of the hardware and software of the device. You cannot
configure anything on this page.
Description of the displayed values
Table 1 has the following columns:
● Hardware
– Basic Device
Shows the basic device
– PX.X
X.X = port in which the SFP module is inserted.
– Slot X
"X" = slot number: Module plugged into this slot.
● Name
Shows the name of the device or module.
● Revision
Displays the hardware version of the device.
● Order ID
Shows the article number of the device or described module.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
69
Configuring with Web Based Management
5.3 The "Information" menu
Table 2 has the following columns:
● Software
– Firmware
Shows the current firmware version. If a new firmware file was downloaded and the
device has not yet restarted, the firmware version of the downloaded firmware file is
displayed here. After the next restart, the downloaded firmware is activated and used.
– Bootloader
Shows the version of the boot software stored on the device.
● Description
Shows the short description of the software.
● Version
Shows the version number of the software version.
● Date
Shows the date on which the software version was created.
5.3.3
Identification & Maintenance
Identification and Maintenance data
This page contains information about device-specific vendor and maintenance data such as
the order number, serial number, version number etc. You cannot configure anything on this
page.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
70
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following rows:
● Manufacturer ID
Shows the manufacturer ID.
● Order ID
Shows the order number.
● Serial Number
Shows the serial number.
● Hardware Revision
Shows the hardware version.
● Software version
Shows the software version.
● Revision Counter
Regardless of a version change, this box always displays the value "0".
● Revision Date
Date and time of the last revision
● Function tag
Shows the function tag (plant designation) of the device. The plant designation (HID) is
created during configuration of the device with HW Config of STEP 7.
● Location tag
Shows the location tag of the device. The location identifier (LID) is created during
configuration of the device with HW Config of STEP 7.
● Date
Shows the date created during configuration of the device with HW Config of STEP 7.
● Descriptor
Shows the description created during configuration of the device with HW Config of
STEP 7.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
71
Configuring with Web Based Management
5.3 The "Information" menu
5.3.4
ARP / Neighbors
5.3.4.1
ARP Table
Assignment of MAC address and IPv4 address
With the Address Resolution Protocol (ARP), there is a unique assignment of MAC address
to IPv4 address. This assignment is kept by each network node in its own separate ARP
table. The WBM page shows the ARP table of the device.
Description of the displayed values
The table has the following columns:
● Interface
Shows the interface via which the row entry was learnt.
● MAC Address
Shows the MAC address of the destination or source device.
● IP Address
Shows the IP address of the destination device.
● Media Type
Shows the type of connection.
– Dynamic
The device recognized the address data automatically.
– Static
The addresses were entered as static addresses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
72
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.4.2
IPv6 Neighbor Table
Assignment of MAC address and IPv6 address
Via the IPv6 neighbor table, there is a unique assignment of MAC address to IPv6 address.
This assignment is kept by each network node in its own separate neighbor table.
Description of the displayed values
The table has the following columns:
● Interface
Displays the interface via which the row entry was learnt.
● MAC Address
Shows the MAC address of the destination or source device.
● IP Address
Shows the IPv6 address of the destination device.
● Media Type
Shows the type of connection.
– Dynamic
The device recognized the address data automatically.
– Static
The addresses were entered as static addresses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
73
Configuring with Web Based Management
5.3 The "Information" menu
5.3.5
Log Table
Logging events
The device allows you to log occurring events, some of which you can specify on the page of
the "System > Events" menu. This, for example, allows you to record when an authentication
attempt failed or when the connection status of a port has changed.
The content of the events log table is retained even when the device is turned off.
Description of the displayed values
Severity Filters
You can filter the entries in the table according to severity. Select the required entries in the
check boxes above the table.
● Info
Information
When this parameter is enabled, all entries of the category "Info" are displayed.
● Warning
Warnings
When this parameter is enabled, all entries of the category "Warning" are displayed.
● Critical
Critical
When this parameter is enabled, all entries of the category "Critical" are displayed.
To display all entries, select either all of them or leave the check boxes empty.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
74
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
The table has the following columns:
● Restart
Counts the number of restarts since you last reset to factory settings and shows the
device restart after which the corresponding event occurred.
● System Up Time
Shows the time the device has been running since the last restart when the described
event occurred.
If the system time is set, the time is also displayed at which the event occurred.
● System Time
Shows the date and time of the device.
● Severity
Sorts the entry into the categories above.
● Log Message
Displays a brief description of the event that has occurred.
Description of the buttons and input boxes
"Clear" button
Click this button to delete the content of the event log file. All entries are deleted regardless
of what you have selected under "Severity Filters".
The display is also cleared. The restart counter is only reset after you have restored the
device to the factory settings and restarted the device.
Note
The table can contain 400 entries for each severity. The number of entries in this table is
restricted to 1200. When this number is reached, the oldest entries are discarded. The table
remains permanently in memory.
"Show all" button
Click this button to display all the entries on the WBM page. Note that displaying all
messages can take some time.
"Next" button
Click this button to go to the next page.
"Prev" button
Click this button to go to the previous page.
Drop-down list for page change
From the drop-down list, select the page you want to go to.
"Update" button
Refreshes the display of the values in the table.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
75
Configuring with Web Based Management
5.3 The "Information" menu
5.3.6
Faults
Error status
This page displays any errors that occur. Errors of the "Cold/Warm Start" event can be
deleted following confirmation.
If there are no more unanswered error/fault messages, the fault LED goes off.
The time calculation always begins after the last system start. When the system is restarted,
a new entry with the type of restart is created in the fault memory.
Description of the displayed values
● No. of Signaled Faults
Number of errors displayed since the last startup.
The table contains the following columns:
● Fault Time
Shows the time the device has been running since the last restart when the described
error/fault occurred.
● Fault description
Display of the fault state for the device.
● Clear Fault State
If the "Clear Fault State" button is enabled, you can delete the fault.
Description of the button
"Reset Counters" button
Click "Reset Counters" to reset all counters. The counters are reset by a restart.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
76
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.7
Redundancy
5.3.7.1
Spanning Tree
Introduction
The page shows the current information about the Spanning Tree and the settings of the root
bridge.
Description of the displayed values
The following fields are displayed:
● Spanning Tree Mode
Shows the set mode. You specify the mode in "Layer 2 > Configuration" and in "Layer 2 >
MSTP > General".
The following values are possible:
– '-'
– STP
– RSTP
– MSTP
● Instance ID
Shows the number of the instance. The parameter depends on the configured mode.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
77
Configuring with Web Based Management
5.3 The "Information" menu
● Bridge Priority / Root Priority
Which device becomes the root bridge is decided by the bridge priority. The bridge with
the highest priority (in other words, with the lowest value for this parameter) becomes the
root bridge. If several devices in a network have the same priority, the device whose MAC
address has the lowest numeric value will become the root bridge. Both parameters,
bridge priority and MAC address together form the bridge identifier. Since the root bridge
manages all path changes, it should be located as centrally as possible due to the delay
of the frames. The value for the bridge priority is a whole multiple of 4096 with a range of
values from 0 to 32768.
● Bridge Address / Root Address
The bridge address shows the MAC address of the device and the root address shows
the MAC address of the root switch.
● Root Cost
Shows the path costs from the device to the root bridge.
● Bridge Status
Shows the status of the bridge, e.g. whether or not the device is the root bridge.
● Regional root priority (available only with MSTP)
For a description, see Bridge priority / Root priority
● Regional root address (available only with MSTP)
Shows the MAC address of the device.
● Regional Root Cost (available only with MSTP)
Shows the path costs from the regional root bridge to the root bridge.
The table has the following columns:
● Port
Shows the port via which the device communicates. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
● Role
Shows the status of the port. The following values are possible:
– Disabled
The port was removed manually from the Spanning Tree and will no longer be taken
into account by the Spanning Tree.
– Designated
The ports leading away from the root bridge.
– Alternate
The port with an alternative route to a network segment
– Backup
If a switch has several ports to the same network segment, the "poorer" Port becomes
the backup port.
– Root
The port that provides the best route to the root bridge.
– Master
This port points to a root bridge located outside the MST region.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
78
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Status
Displays the current status of the port. The values are only displayed. The parameter
depends on the configured protocol. The following statuses are possible:
– Discarding
The port receives BPDU frames. Other incoming or outgoing frames are discarded.
– Listening
The port receives and sends BPDU frames. The port is involved in the spanning tree
algorithm. Other outgoing and incoming frames are discarded.
– Learning
The port actively learns the topology; in other words, the node addresses. Other
outgoing and incoming frames are discarded.
– Forwarding
Following the reconfiguration time, the port is active in the network. The port receives
and sends data frames.
● Oper. Version
Describes the type of spanning tree in which the port operates
● Priority
If the path calculated by the spanning tree is possible over several ports of a device, the
port with the highest priority (in other words the lowest value for this parameter) is
selected. A value between 0 and 240 can be entered for the priority in steps of 16. If you
enter a value that cannot be divided by 16, the value is automatically adapted. The
default is 128.
● Path Cost
This parameter is used to calculate the path that will be selected. The path with the
lowest value is selected. If several ports of a device have the same value, the port with
the lowest port number will be selected.
If the value in the "Cost Calc." box is "0", the automatically calculated value is shown.
Otherwise, the value of the "Cost Calc." is displayed.
The calculation of the path costs is largely based on the transmission speed. The higher
the achievable transmission speed is, the lower the value of the path costs.
Typical values for path costs with rapid spanning tree:
– 10,000 Mbps = 2,000
– 1000 Mbps = 20,000
– 100 Mbps = 200,000
– 10 Mbps = 2,000,000.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
79
Configuring with Web Based Management
5.3 The "Information" menu
● Edge Type
Shows the type of the connection. The following values are possible:
– Edge Port
There is an end device at this port.
– No Edge Port
There is a Spanning Tree or Rapid Spanning Tree device at this port.
● P.t.P. Type
Shows the type of point-to-point link. The following values are possible:
– P.t.P.
With half duplex, a point-to-point link is assumed.
– Shared Media
With a full duplex connection, a point-to-point link is not assumed.
5.3.7.2
VRRP statistics
Introduction
This page shows the statistics of the VRRP protocol and all configured virtual routers.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
80
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The following fields are displayed:
● VRID Errors
Shows how many VRRP packets containing an unsupported VRID were received.
● Version Errors
Shows how many VRRP packets containing an invalid version number were received.
● Checksum Errors
Shows how many VRRP packets containing an invalid checksum were received.
The table has the following columns:
● Interface
Interface to which the settings relate.
● VRID
Shows the ID of the virtual router.
Valid values are 1 to 255.
● Become Master
Shows how often this virtual router changed to the "Master" status.
● Advertisements Received
Shows how often a VRRP packet was received that contained a bad address list.
● Advertisement Interval Errors
Shows how many bad VRRP packets were received whose interval does not match the
value set locally.
● IP TTL Errors
Shows how many bad VRRP packets were received whose TTL (Time to live) value in
the IP header is incorrect.
● Prio 0 received
Shows how many VRRP packets with priority 0 were received. VRRP packets with priority
0 are sent when a master router is shut down. These packets allow a fast handover to the
relevant backup router.
● Prio 0 sent
Shows how many VRRP packets with priority 0 were sent. Packets with priority 0 are sent
when a master router is shut down. These packets allow a fast handover to the relevant
backup router.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
81
Configuring with Web Based Management
5.3 The "Information" menu
● Invalid Type
Shows how many bad VRRP packets were received whose authentication type was not
type 0. Type 0 means "no authentication".
● Address List Errors
Shows how many bad VRRP packets were received whose address list does not match
the locally configured list.
● Invalid Auth. Type
Shows how many bad VRRP packets were received whose authentication type does not
match.
● Auth. Type Mismatch
Shows that different authentication types are set.
● Packet Length Errors
Shows how many bad VRRP packets were received whose length is not correct.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
82
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.7.3
VRRP Statistics
Introduction
This page shows the statistics of the VRRPv3 protocol and all configured virtual routers.
Description of the displayed values
The following fields are displayed:
● VRID Errors
Shows how many VRRPv3 packets containing an unsupported VRID were received.
● Version Errors
Shows how many VRRPv3 packets containing an invalid version number were received.
● Checksum Errors
Shows how many VRRPv3 packets containing an invalid checksum were received.
The table has the following columns:
● Interfaces
Interface to which the settings relate.
● VRID
Shows the ID of the virtual router. Valid values are 1 ... 255.
● Type
Shows the version of the IP protocol.
● Become Master
Shows how often this virtual router changed to the "Master" status.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
83
Configuring with Web Based Management
5.3 The "Information" menu
● Advertisements Received
Shows how many VRRPv3 packets were received.
● Advertisement Interval Errors
Shows how many bad VRRPv3 packets were received whose interval does not match the
value set locally.
● IP TTL Errors
Shows how many bad VRRPv3 packets were received whose TTL (Time to live) value in
the IP header is incorrect.
● Prio 0 received
Shows how many VRRPv3 packets with priority 0 were received. VRRPv3 packets with
priority 0 are sent when a master router is shut down. These packets allow a fast
handover to the relevant backup router.
● Prio 0 sent
Shows how many VRRPv3 packets with priority 0 were sent. Packets with priority 0 are
sent when a master router is shut down. These packets allow a fast handover to the
relevant backup router.
● Invalid Type
Shows how many bad VRRPv3 packets were received whose value in the "Type" field of
the IP header is invalid.
● Address List Errors
Shows how many bad VRRPv3 packets were received whose address list does not
match the locally configured list.
● Packet Length Errors
Shows how many bad VRRPv3 packets were received whose length is not correct.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
84
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.7.4
Ring redundancy
Information on ring redundancy
On this page, you obtain information about the status of the device in terms of ring
redundancy. The text boxes on this page are read-only.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
85
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Redundancy Function
The "Redundancy Function" column shows the role of the device within the ring:
– No Ring Redundancy (off)
The IE switch works without redundancy function.
– HRP Client
The IE switch operates as an HRP client.
– HRP Manager
The IE switch operates as an HRP manager.
– MRP Client
The IE switch operates as an MRP client.
– MRP Manager
The IE switch operates as an MRP manager. Using STEP 7, the role "Manager" was
set for the device.
– MRP Auto-Manager
The IE switch is operating as an MRP manager. Using WBM or CLI the role "MRP
Auto-Manager" or using STEP 7 the role "Manager (Auto)" was set.
● RM Status
The "RM Status" column shows whether or not the IE switch is operating as redundancy
manager and whether it has opened or closed the ring in this role.
– Passive:
The IE switch is operating as redundancy manager and has opened the ring; in other
words, the line of switches connected to the ring ports is operating problem free. The
passive status is also displayed if the IE switch is not operating as the redundancy
manager (RM function disabled).
– Active:
The IE switch is operating as redundancy manager and has closed the ring; in other
words, the line of switches connected to the ring ports is interrupted (problem). The
redundancy manager connects its ring ports through and restores an uninterrupted
linear topology.
– If media redundancy in ring topologies is completely disabled, ring ports configured
last are displayed and the text "Ring Redundancy disabled" is displayed.
● Observer Status
Shows the current status of the observer.
● Ring Port 1 and Ring Port 2
The "Ring Port 1" and "Ring Port 2" columns show the ports being used as ring ports.
● No. of Changes to RM Active State
Shows how often the device as redundancy manager switched to the active status, i.e.
closed the ring.
If the redundancy function is disabled or the device is an "HRP/MRP client" , the text
"Redundancy Manager Disabled" appears.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
86
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Max. Delay of the RM Test Packets [ms]
Shows the maximum delay time of the test frames of the redundancy manager.
If the redundancy function is disabled or the device is an "HRP/MRP client" , the text
"Redundancy Manager Disabled" appears.
● Click the "Reset Counters" button to reset the counters on this page.
5.3.7.5
Standby
Information on standby redundancy
On this page, you obtain information about the status of the device in terms of standby
redundancy. The text boxes on this page are read-only.
Note
Device with the higher MAC address becomes master
When linking HRP rings redundantly, two devices are always configured as a master/slave
pair. This also applies to interrupted HRP rings = linear buses. When operating normally, the
device with the higher MAC address adopts the role of master.
This type of assignment is important in particular when a device is replaced. Depending on
the MAC addresses, the previous device with the slave function can take over the role of the
standby master.
The Standby tab shows the status of the standby function:
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
87
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Standby Ports
Shows the standby port.
● Standby Name
Standby Connection Name
● Standby Function
– Master:
The device has a connection to the partner device and is operating as master. In
normal operation, the standby port of this device is active.
– Slave:
The device has a connection to the partner device and is operating as slave. In normal
operation, the standby port of this device is inactive.
– Disabled:
Standby link is disabled. The device is operating neither as master nor slave. The port
configured as a standby port works as a normal port without standby function.
– Waiting for Connection....:
No connection has yet been established to the partner device. The standby port is
inactive. In this case, either the configuration on the partner device is inconsistent (for
example incorrect connection name, standby link disabled) or there is a physical fault
(for example device failure, link down).
– Connection Lost:
Existing connection to the partner device has been lost. In this case, either the
configuration on the partner device was modified (for example a different connection
name, standby link disabled) or there is a physical fault (for example device failure,
link down).
● Standby Status
The "Standby Status" display box shows the status of the standby port:
– Active:
The standby port of this device is active; in other words is enabled for frame traffic.
– Passive:
The standby port of this device is inactive; in other words is blocked for frame traffic.
– "-":
The standby function is disabled.
● No. of Changes to Standby Active State
Shows how often the IE switch has changed the standby status from "Passive" to
"Active". If the connection of a standby port fails on the standby master, the IE switch
changes to the "Active" status.
If the standby function is disabled, the text "Standby Disabled" appears in this box.
Click the "Reset Counters" button to reset the counters on this page.
Following each restart on the device, the counters are automatically reset.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
88
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.8
Ethernet Statistics
5.3.8.1
Interface Statistics
Interface statistics
The page shows the statistics from the interface table of the Management Information Base
(MIB).
Description of the displayed values
The table has the following columns:
● In Octet
Shows the number of received bytes.
● Out Octet
Shows the number of sent bytes.
● In Unicast
Shows the number of received unicast frames.
● In Non Unicast
Shows the number of received frames that are not of the type unicast.
● Out Unicast
Shows the number of sent unicast frames.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
89
Configuring with Web Based Management
5.3 The "Information" menu
● Out Non Unicast
Shows the number of sent frames that are not of the type unicast.
● In Errors
Shows the number of all possible RX errors, refer to the tab "Packet Error".
5.3.8.2
Packet Size
Frames sorted by length
This page displays how many frames of which size were sent and received at each port. You
cannot configure anything on this page.
The displayed values are transferred by RMON.
On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be
displayed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
90
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Port
Shows the available ports and link aggregations. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
Note
Display of frame statistics
In the statistics relating to frame size, note that both incoming and outgoing frames are
counted.
● Frame lengths
The other columns after the port number contain the absolute numbers of frames
according to their frame length.
The following frame lengths are distinguished:
– 64 bytes
– 65 - 127 bytes
– 128 - 255 bytes
– 256 - 511 bytes
– 512 - 1023 bytes
– 1024 - max.
Note
Data traffic on blocked ports
For technical reasons, data packets can be indicated on blocked ports.
Description of the button
"Reset Counters" button
Click "Reset Counters" to reset all counters. The counters are reset by a restart.
5.3.8.3
Frame Type
Received frames sorted by type
This page displays how many frames of the type "Unicast", "Multicast" and "Broadcast" were
received at each port. You cannot configure anything on this page.
The displayed values are transferred by RMON.
On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be
displayed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
91
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Port
Shows the available ports and link aggregations. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
● Unicast / Multicast / Broadcast
The other columns after the port number contain the absolute numbers of the incoming
frames according to their frame type "Unicast", "Multicast" and "Broadcast".
Description of the button
"Reset Counters" button
Click "Reset Counters" to reset all counters. The counters are reset by a restart.
5.3.8.4
Packet Error
Bad received frames
This page shows how many bad frames were received per port. You cannot configure
anything on this page.
The displayed values are transferred by RMON.
On the page "Layer 2 > RMON > Statistics", you can set the ports for which values will be
displayed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
92
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Port
Shows the available ports and link aggregations. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
● Error types
The other columns after the port number contain the absolute numbers of the incoming
frames according to their error type.
In the columns of the table, a distinction is made according to the following error types:
– CRC
Packets whose content does not match the CRC checksum.
– Undersize
Packets with a length less than 64 bytes.
– Oversize
Packets discarded because they were too long.
– Fragments
Packets with a length less than 64 bytes and a bad CRC checksum.
– Jabbers
VLAN-tagged packets with an incorrect CRC checksum that were discarded because
they were too long.
– Collisions
Collisions that were detected.
Description of the button
"Reset Counters" button
Click "Reset Counters" to reset all counters. The counters are reset by a restart.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
93
Configuring with Web Based Management
5.3 The "Information" menu
5.3.8.5
History
Samples of the statistics
The page shows samples from each port with information from the RMON statistics.
On the page "Layer 2 > RMON > History", you can set the ports for which samples will be
taken.
Figure 5-2
History
Settings
● Port
Select the port for which the history will be displayed.
Description of the displayed values
● Entries
Maximum number of samples that can be saved at the same time.
● Interval [s]
Interval after which the current status of the statistics will be saved as a sample.
The table has the following columns:
● Sample
Number of the sample
● Sample Time
System up time at which the sample was taken.
● Unicast
Number of received unicast frames.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
94
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Multicast
Number of received multicast frames.
● Broadcast
Number of received broadcast frames.
● CRC
Number of frames with a bad CRC checksum.
● Undersize
Number of frames that are shorter than 64 bytes.
● Oversize
Number of frames discarded because they were too long.
● Fragments
Number of frames that are shorter than 64 bytes and have a bad CRC checksum.
● Jabbers
Number of frames with a VLAN tag that have a bad CRC checksum and will be discarded
because they are too long.
● Collisions
Number of collisions of received frames.
● Utilization [%]
Utilization of the port during a sample.
5.3.9
Unicast
Status of the unicast filter table
This page shows the current content of the unicast filter table. This table lists the source
addresses of unicast address frames. Entries can be made either dynamically when a node
sends a frame to a port or statically by the user setting parameters.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
95
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
This table contains the following columns:
● VLAN ID
Shows the VLAN-ID assigned to this MAC address.
● MAC Address
Shows the MAC address of the node that the device has learned or the user has
configured.
● Status
Shows the status of each address entry:
– Learnt
The specified address was learned by receiving a frame from this node and will be
deleted when the aging time expires if no further packets are received from this node.
Note
If there is a link down, learned MAC entries are deleted.
– Static
Configured by the user. Static addresses are stored permanently; in other words, they
are not deleted when the aging time expires or when the switch is restarted.
● Port
Shows the port via which the node with the specified address can be reached. Frames
received by the device whose destination address matches this address will be forwarded
to this port.
5.3.10
Multicast
Status of the multicast filter table
This table shows the multicast frames currently entered in the multicast filter table and their
destination ports. The entries can be dynamic (the device has learned them) or static (the
user has set them).
SCALANCE XM-400/XR-500 Web Based Management (WBM)
96
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
This table contains the following columns:
● VLAN ID
Shows VLAN ID of the VLAN to which the MAC multicast address is assigned.
● MAC Address
Shows the MAC multicast address that the device has learned or the user has
configured.
● Status
Shows the status of each address entry. The following information is possible:
– Static
The address was entered statically by the user. Static addresses are stored
permanently; in other words, they are not deleted when the aging time expires or
when the device is restarted. These must be deleted by the user.
– IGMP
The destination port for this address was obtained by IGMP configuration.
– MLD
The destination port for this address was determined by MLD configuration.
– GMRP
The destination port for this address was registered by a received GMRP frame.
● Port List
There is a column for each slot. Within a column, the multicast group to which the port
belongs is shown:
– M
(Member) Multicast frames are sent via this port.
– R
(Registered) Member of the multicast group, registration was by a GMRP frame.
– I
(IGMP/MLD) Member of the multicast group, registration was by an IGMP/MLD frame.
– –
Not a member of the multicast group. No multicast frames with the defined multicast
MAC address are sent via this port.
– F
(Forbidden) Not a member of the multicast group. Moreover, this address may not be
an address learned dynamically with GMRP or IGMP/MLD.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
97
Configuring with Web Based Management
5.3 The "Information" menu
5.3.11
LLDP
Status of the neighborhood table
This page shows the current content of the neighborhood table. This table stores the
information that the LLDP agent has received from connected devices.
You set the interfaces via which the LLDP agent receives or sends information in the
following section: "Layer 2 > LLDP".
Figure 5-3
Information LLDP
Description of the displayed values
This table contains the following columns:
● System Name
System name of the connected device.
● Device ID
Device ID of the connected device.
● Local Interface
Port at which the IE switch received the information.
● Hold Time
An entry remains stored in the MIB for the time specified here. If the IE switch does not
receive any new information from the connected device during this time, the entry is
deleted.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
98
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Capability
Shows the properties of the connected device:
– Router
– Bridge
– Telephone
– DOCSIS Cable Device
– WLAN Access Point
– Repeater
– Station
– Other
● Port ID
Port of the device with which the IE switch is connected.
5.3.12
Fiber Monitoring Protocol
Monitoring optical links
With Fiber Monitoring, you can monitor optical links. The table shows the current status of
the ports.
You set the values to be monitored on the following page: "Layer 2 > FMP".
Description of the displayed values
Port
Shows the optical ports that support fiber monitoring. This depends on the transceivers.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
99
Configuring with Web Based Management
5.3 The "Information" menu
Rx Power State
● disabled
Fiber monitoring is disabled.
● ok
The value for the received power of the optical link is within the set limits.
● maint. req.
Check the link.
A warning is signaled.
● maint. dem.
The link needs to be checked.
An alarm is signaled and the fault LED is lit.
● link down
The connection to the communications partner is down. No link is detected.
Rx Power [dBm]
Shows the current value of the received power. The value can have a tolerance of +/- 3 dB.
If there is no connection (link down) or fiber monitoring is disabled, "-" is displayed. If fiber
monitoring is not enabled on the partner port, the value 0.0 is displayed.
Power Loss State
To be able to monitor the power loss of the connection the function fiber monitoring must be
enabled for the optical port of the connection partner.
● disabled
Fiber monitoring is disabled.
● ok
The value for the power loss of the optical link is within the defined limits.
● maint. req.
Check the link.
A warning is signaled.
● maint. dem.
The link needs to be checked.
An alarm is signaled and the fault LED is lit.
● idle
The port has no connection to another port with fiber monitoring enabled.
If no diagnostics information is received from the optical port of the connection partner for
5 cycles, the fiber monitoring connection is assumed to be interrupted. A cycle lasts 5
seconds.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
100
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Power Loss [dB]
Shows the current value of the power loss. The value can have a tolerance of +/- 3 dB.
If there is no connection (link down), fiber monitoring is disabled or the partner port does not
support fiber monitoring, "-" is displayed.
5.3.13
IPv4 routing
5.3.13.1
Routing Table
Introduction
This page shows the routes currently being used.
Description of the displayed values
The table has the following columns:
● Destination Network
Shows the destination address of this route.
● Subnet Mask
Shows the subnet mask of this route.
● Gateway
Shows the gateway for this route.
● Interface
Shows the interface for this route.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
101
Configuring with Web Based Management
5.3 The "Information" menu
● Metric
Shows the metric of the route. The higher value, the longer packets require to their
destination.
● Routing Protocol
Shows the routing protocol from which the entry in the routing table originates. The
following entries are possible:
– connected: Connected routes
– Static: Static routes
– RIP: Routes via RIP
– OSPF: Routes via OSPF
– Other: Other routes
5.3.13.2
OSPFv2 Interfaces
Overview
This page shows the configuration of the OSPF interface.
Description of the displayed values
The table has the following columns:
● IP address
Shows the IPv4 address of the OSPF interface
● Area ID
Shows the area ID to which the OSPF interface belongs.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
102
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Interface Status
Shows the status of the WLAN interface:
– Down
The interface is not available.
– Loop back
Loop back interface
– Waiting
Starting up and negotiating the interface.
– Point to Point
Point-to-point link
– Designated Router
The router is a designated router and generates network LSAs.
– Backup D. Router
The router is the backup router for the designated router.
– Other D. Router
The Interface has started up. The router is neither a designated nor a designated
backup router.
● OSPF Status
Shows the status of OSPF.
– Enabled: OSPF is enabled on the interface.
– Disabled: OSPF is disabled on the interface.
● Designated Router
Shows the IPv4 address of the designated router for this OSPF interface.
● Backup Designated Router
Shows the IPv4 address of the designated backup router for this OSPF interface.
● Events
Shows the number of status changes of OSPF.
5.3.13.3
OSPFv2 Neighbors
Overview
This page shows the dynamically detected neighbor routers in the relevant networks.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
103
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● IP Address
Shows the IPv4 address of the neighbor router in this network.
● Router ID
Shows the ID of the neighbor router. The two addresses can match.
● Status
Shows the status of the neighbor router. The status can adopt the following values:
– unknown
Status of the neighbor router is unknown.
– down
The neighbor router cannot be reached.
– attempt and init
Brief status during initialization
– two-way
Two-way receipt of Hello packets. Specification of the designated router and the
designated backup router.
– exchangestart, exchange and loading
Status during exchange of the LSAs
– full
The database is complete and synchronized within the area. The routes can now be
detected.
Note
Normal status
If the partner router is a designated router or a designated backup router, the status is
"full". Otherwise the status is "two-way".
● Assoc. Area Type
Shows the area type via which the neighbor-neighbor relation is maintained. The
following area types exist:
– Standard
– Stub
– NSSA
– Backbone
● Priority
Shows the priority of the neighbor router. This is only significant when selecting the
designated router on a network. For virtual neighbor routers, this information is irrelevant.
● Hello suppr
Shows the suppressed Hello packets to the neighbor router. This field normally displays
"no".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
104
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Hello Queue
Shows the length of the queue with Hello packets still to be transmitted.
● Events
Shows the number of status changes.
5.3.13.4
OSPFv2 Virtual Neighbors
Overview
This page shows the configured virtual neighbors.
Description of the displayed values
The table has the following columns:
● IP Address
Shows the IPv4 address of the virtual neighbor router in this network.
● Router ID
Shows the router ID of the virtual neighbor router.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
105
Configuring with Web Based Management
5.3 The "Information" menu
● Status
Shows the status of the neighbor router. The status can adopt the following values:
– unknown
Status of the neighbor router is unknown.
– down
The neighbor router cannot be reached.
– attempt and init
Brief status during initialization
– two-way
Two-way receipt of Hello packets. Specification of the designated router and the
designated backup router.
– exchangestart, exchange and loading
Status during exchange of the LSAs
– full
The database is complete and synchronized within the area. The routes can now be
detected.
Note
Normal status
If the partner router is a designated router or a designated backup router, the status is
"full". Otherwise the status is "two-way".
● Trans. Area ID
Shows the ID of the area via which the virtual neighborhood relation exists.
● Hello Suppr.
Shows whether there are suppressed Hello packets to the virtual neighbor router.
– no: There are no suppressed Hello packets (default)
– yes: There are suppressed Hello packets.
● Hello Queue
Shows the length of the queue with Hello packets still to be transmitted.
● Events
Shows the number of status changes.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
106
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.13.5
OSPFv2 LSDB
Overview
The link state database is the central database for managing all links within an area. It
consists of the link state advertisements (LSAs). The most important data of these LSAs is
shown on the this WBM page.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
107
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed boxes
The table has the following columns:
● Area ID
Shows the ID of the area to which the LSA belongs. If the LSA is an external connection,
'-' is displayed.
● Link State Type
Shows the LSA type. The following values are possible:
– Unknown
LSA type is unknown.
– Router
The router LSA (Type 1) is sent by the OSPF router within an area. The LSA contains
information about the status of all router interfaces.
– Network
The network LSA (Type 2) is sent by the designated router within an area. The LSA
contains a list of routers connected to the network.
– NSSA External
The NSSA external LSA (Type 7) is sent by the NSSA-ASBR within an NSSA. The
NSSA-ASBR receives LSAs of Type 5 and converts the information to LSAs of Type
7. The NSSA router can forward these LSAs within an NSSA.
– Summary
The summary LSA (Type 3) is sent by the ABR within an area. The LSA contains
information about routes to other networks.
– AS Summary
The AS summary LSA (Type 4) is sent by the area border router within an area. The
LSA contains information about routes to other autonomous systems.
– AS External
The AS external LSA (Type 5) is sent by the AS border router within an autonomous
system. The LSA contains information about routes from one network to another.
● Link State ID
Shows the ID of the LSA.
● Router ID
Shows the ID of the router that sent this LSA.
● Sequence Number
Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence
number is incremented by one.
5.3.13.6
RIPv2 Statistics
Overview
This page shows the statistics of the RIP interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
108
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
Figure 5-4
RIPv2 Statistics information
The table has the following columns:
● IP Address
Shows the IPv4 address of the RIPv2 interface
● Bad packets
Number of received RIP packets that were deleted and therefore ignored.
● Bad Routes
Number of routes of valid RIP packets that could not be taken into consideration.
● Updates Sent
Shows how often the router has sent its routing table to its neighbor routers.
5.3.14
IPv6 routing
5.3.14.1
IPv6 Routing Table
Introduction
This page shows the IPv6 routes currently being used.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
109
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Destination Network
Shows the destination address of this route.
● Prefix Length
Shows the prefix length of this route.
● Gateway
Shows the gateway for this route.
● Interface
Shows the interface for this route.
● Metric
Shows the metric of the route. The higher value, the longer packets require to their
destination.
● Routing Protocol
Shows the routing protocol from which the entry in the routing table originates. The
following entries are possible:
– connected: Connected routes
– Static: Static routes
– RIPng: Routes via RIPng
– OSPFv3: Routes via OSPFv3
– other: Other routes
5.3.14.2
OSPFv3 Interfaces
Overview
This page shows the configuration of the OSPFv3 interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
110
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Interface
Shows the interface to which the settings relate.
● Area ID
Shows the Area ID to which the OSPF interface belongs.
● Interface Status
Shows the status of the interface.
– Down
The interface is not available.
– Loop back
Loop back interface
– Waiting
Startup and negotiation of the interface.
– Point to Point
Point-to-point connection
– Designated Router
The router is a designated router and generates network LSAs.
– Backup D. Router
The router is the backup router for the designated router.
– S D. Router
The Interface has started up. The router is neither a designated nor a designated
backup router.
● OSPF Status
Shows the status of OSPF.
– Enabled: OSPF is enabled on the interface.
– Disabled: OSPF is disabled on the interface.
● Designated Router
Shows the IPv6 address of the designated router for this OSPFv3 interface.
● Backup Designated Router
Shows the IPv6 address of the designated backup router for this OSPFv3 interface.
● Events
Shows the number of status changes of OSPFv3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
111
Configuring with Web Based Management
5.3 The "Information" menu
5.3.14.3
OSPFv3 Neighbors
Overview
This page shows the dynamically detected neighbor routers in the relevant networks.
Description of the displayed values
The table has the following columns:
● Interface
Displays the OSPFv3 interface via which the neighbor router can be reached.
● Router ID
Shows the ID of the neighbor router.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
112
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Status
Shows the status of the neighbor router. The status can adopt the following values:
– unknown
Status of the neighbor router is unknown.
– down
The neighbor router cannot be reached.
– attempt und init
Short-lived status during initialization
– two-way
Two-way receipt of Hello packets. Specification of the designated router and the
designated backup router.
– exchangestart, exchange und loading
Status during exchange of the LSAs
– full
The database is complete and synchronized within the area. The routes can now be
detected.
Note
Normal status
If the partner router is a designated router or a designated backup router, the status is
"full". Otherwise the status is "two-way".
● Assoc. Area Type
Shows the area type via which the neighbor-neighbor relation is maintained. The
following area types exist:
– Standard
– Stub
– NSSA
– Backbone
● Priority
Shows the priority of the neighbor router. This is only significant when selecting the
designated router on a network. For virtual neighbor routers, this information is irrelevant.
● Hello suppr
Shows the suppressed Hello packets to the neighbor router. This field normally displays
"no".
● Hello Queue
Shows the length of the queue with Hello packets still to be transmitted.
● Events
Shows the number of status changes.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
113
Configuring with Web Based Management
5.3 The "Information" menu
5.3.14.4
OSPFv3 Virtual Neighbors
Overview
This page shows the configured virtual neighbors.
Description of the displayed values
The table has the following columns:
● Interface
Displays the OSPFv3 interface via which the neighbor router can be reached.
● Router ID
Shows the ID of the virtual neighbor router.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
114
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
● Status
Shows the status of the virtual neighbor router. The status can adopt the following values:
– unknown
Status of the neighbor router is unknown.
– down
The neighbor router cannot be reached.
– attempt und init
Short-lived status during initialization
– two-way
Two-way receipt of Hello packets. Specification of the designated router and the
designated backup router.
– exchangestart, exchange und loading
Status during exchange of the LSAs
– full
The database is complete and synchronized within the area. The routes can now be
detected.
Note
Normal status
If the partner router is a designated router or a designated backup router, the status is
"full". Otherwise the status is "two-way".
● Trans. Area ID
Shows the ID of the area via which the virtual neighborhood relation exists.
● Hello suppr
Shows the suppressed Hello packets to the neighbor router. This field normally displays
"no".
● Hello Queue
Shows the length of the queue with Hello packets still to be transmitted.
● Events
Shows the number of status changes.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
115
Configuring with Web Based Management
5.3 The "Information" menu
5.3.14.5
OSPFv3 AS-Scope LSDB
Overview
The AS-Scope LSDB consists of AS external LSAs. The most important data of these LSAs
is shown on this page.
Description of the displayed values
The table has the following columns:
● Link State Type
– AS External
The AS external LSA (Type 0x4005) is sent by the AS border router within an
autonomous system. The LSA contains information about routes from one network to
another.
● Link State ID
Shows the ID of the LSA.
● Router ID
Shows the ID of the router that sent this LSA.
● Sequence Number
Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence
number is incremented by one.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
116
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.14.6
OSPFv3 Area-Scope LSDB
Overview
The Area-Scope LSDB is the central database for managing all links within an area. The
most important data of the LSAs is shown on this page.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
117
Configuring with Web Based Management
5.3 The "Information" menu
Description of the displayed values
The table has the following columns:
● Area ID
Shows the ID of the area to which the LSA belongs. If the LSA is an external connection,
'-' is displayed.
● Link State Type
Shows the LSA type. The following values are possible:
– Router
The router LSA (Type 0x2001) is sent by the OSPF router within an area. The LSA
contains information about the status of all router interfaces. However, no longer
contains address information. This is contained in the new LSA type 0x2009.
– Network
The network LSA (Type 0x2002) is sent by the designated router within an area. The
LSA contains a list of routers connected to the network. However, no longer contains
address information. This is contained in the new LSA type 2009.
– Inter-Area Prefix
the inter-area prefix LSA (Type 0x2003) is sent by the ABR within an area. The LSA
contains information about routes to other networks.
– Inter-Area Router
The inter-area router LSA (Type 0x2004) is sent by the area border router within an
area. The LSA contains information about routes to other autonomous systems.
– Type 7
The Type 7 LSA (Type 0x2007) is sent by the NSSA-ASBR within an NSSA. The
NSSA-ASBR receives LSAs of Type 0x4005 and converts the information to LSAs of
Type 0x2007. The NSSA router can forward these LSAs within an NSSA.
– Intra-Area Prefix
The intra-area prefix LSA (Type 0x2009) is only sent within an area. It contains the
IPv6 prefixes connected to the router or network.
● Link State ID
Shows the ID of the LSA.
● Router ID
Shows the ID of the router that sent this LSA.
● Sequence Number
Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence
number is incremented by one.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
118
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.14.7
OSPFv3 Link-Scope LSDB
Overview
The link scope LSDB consists of the link LSAs. The most important data of these LSAs is
shown on this page.
Description of the displayed values
The table has the following columns:
● Interface
Shows the OSPFv3 interface to which the link LSA belongs.
● Link State Type
– Link
The link LSA (Type 0x2009) is sent by the router to every router linked to it. It contains
the link local address of the router and a list with IPv6 prefixes configured on the link.
● Link State ID
Shows the ID of the LSA.
● Router ID
Shows the ID of the router that sent this LSA.
● Sequence Number
Shows the sequence number of the LSA. Each time an LSA is renewed, this sequence
number is incremented by one.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
119
Configuring with Web Based Management
5.3 The "Information" menu
5.3.14.8
RIPng Statistics
Overview
This page shows the statistics of the RIPng interfaces.
Figure 5-5
RIPng statistics - Part 1
Description of the displayed values
The table has the following columns:
● Interface
Shows the RIPng interface.
● Status
Shows the status of the RIPng interface.
– up
– down
● Messages Received
Shows how often the router has received messages.
● Requests Received
Shows how often the router has received requests.
● Responses Received
Shows how often the router has received responses.
● Unknown Commands
Shows how many RIPng packets were received whose value in the "Commands" field of
the RIPng header is unknown. Known values are 1 for requests and 2 for responses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
120
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Figure 5-6
RIPng statistics - Part 2
● Other version
Shows how many RIPng packets were received whose value in the "Version" field is not
1.
● Discards
Shows how often the router has discarded RIPng packets.
● Messages Sent
Shows how often the router has sent messages.
● Requests Sent
Shows how often the router has sent requests.
● Responses Sent
Shows how often the router has sent responses.
● Updates Sent
Shows how often the router has sent its routing table to its neighbor routers.
5.3.15
SNMP
This page displays the created SNMPv3 groups. You configure the SNMPv3 groups in
"System" > SNMP"..
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
121
Configuring with Web Based Management
5.3 The "Information" menu
Description
The table has the following columns:
● Group Name
Shows the group name.
● User Name
Shows the user that is assigned to the group.
5.3.16
Security
5.3.16.1
Overview
Note
The values displayed depend on the rights of the logged-on user.
This page shows the security settings and the local and external user accounts.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
122
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
Description
Services
The "Services" list shows the security settings.
● Telnet Server
You configure the setting in "System > Configuration".
– enabled: Unencrypted access to the CLI.
– disabled: No unencrypted access to the CLI.
● SSH Server
You configure the setting in "System > Configuration".
– enabled: Encrypted access to the CLI.
– disabled: No encrypted access to the CLI.
● Web Server
You configure the setting in "System > Configuration".
– HTTP/HTTPS: Access to the WBM is possible with HTTP and HTTPS.
– HTTPS: Access to the WBM is now only possible with HTTPS.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
123
Configuring with Web Based Management
5.3 The "Information" menu
● SNMP
You can configure setting in "System > SNMP > General".
– "-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
– SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3.
– SNMPv3
Access to device parameters is possible only with SNMP version 3.
● Login Authentication
You configure the setting in "Security > AAA > General".
– Local
The authentication must be made locally on the device.
– RADIUS
The authentication must be handled via a RADIUS server.
– Local and RADIUS
The authentication is possible both with the users that exist on the device (user name
and password) and via a RADIUS server.
The user is first searched for in the local database. If the user does not exist there, a
RADIUS query is sent.
– RADIUS and fallback local
The authentication must be handled via a RADIUS server.
A local authentication is performed only when the RADIUS server cannot be reached
in the network.
Local and external user accounts
You configure local user accounts and roles in "Security > User Accounts"
When you create a local user account an external user account is generated automatically.
Local user accounts involve users each with a password for logging in on the device.
In the table "External User Accounts" a user is linked to a role. In this example the user
"Observer" is linked to the "user" role. The user is defined on a RADIUS server. The roll is
defined locally on the device. When a RADIUS server authenticates a user, the
corresponding group however is unknown or does not exist, the device checks whether or
not there is an entry for the user in the table "External User Accounts". If an entry exists, the
user is logged in with the rights of the associated role. If the corresponding group is known
on the device, both tables are evaluated. The user is assigned the role with the higher rights.
Note
The table "External User Accounts" is only evaluated if you have set "SiemensVSA" in the
RADIUS Authorization Mode".
With CLI you can access external user accounts.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
124
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
The table "Local User Accounts" has the following columns:
● User Account
Shows the name of the local user.
● Role
Shows the role of the user. You can obtain more information on the function rights of the
role in "Information > Security > Roles".
The table "External User Accounts" has the following columns:
● User Account
Shows the name of the user on the RADIUS server.
● Role
Shows the role assigned to the user on the device. You can obtain more information on
this in "Information > Security > Roles".
5.3.16.2
Supported Function Rights
Note
The values displayed depend on the role of the logged-on user.
The page shows the function rights available locally on the device.
Description of the displayed values
● Function Right
Shows the number of the function right. Different rights relating to the device parameters
are assigned to the numbers.
● Description
Shows the description of the function right.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
125
Configuring with Web Based Management
5.3 The "Information" menu
5.3.16.3
Roles
Note
The values displayed depend on the role of the logged-on user.
The page shows the roles valid locally on the device.
Description of the displayed values
This table contains the following columns:
● Role
Shows the name of the role.
● Function Right
Shows the function right of the role:
– 1
Users with this role can read device parameters but cannot change them.
– 15
Users with this role can both read and change device parameters.
– 0
This is a role that the device assigns internally when a user could not be
authenticated. The user is denied access to the device.
● Description
Shows a description of the role.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
126
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.3 The "Information" menu
5.3.16.4
Groups
Note
The values displayed depend on the role of the logged-on user.
This page shows which group is linked to which role. The group is defined on a RADIUS
server. The roll is defined locally on the device.
Description of the displayed values
The table has the following columns:
● Group
Shows the name of the group. The name matches the group on the RADIUS server.
● Role
Shows the name of the role. Users who are authenticated with the linked group on the
RADIUS server receive the rights of this role locally on the device.
● Description
Shows a a description for the link.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
127
Configuring with Web Based Management
5.4 The "System" menu
5.4
The "System" menu
5.4.1
Configuration
System configuration
The WBM page contains the configuration overview of the access options of the device.
Specify the services that access the device. With some services, there are further
configuration pages on which more detailed settings can be made.
Description of the displayed boxes
The page contains the following boxes:
● Telnet Server
Enable or disable the "Telnet Server" service for unencrypted access to the CLI.
● SSH Server
Enable or disable the "SSH Server" service for encrypted access to the CLI.
● HTTPS Server only
If this function is enabled, you can only access the device via HTTPS.
● DNS Client
Enable or disable depending on whether the IE switch should operate as a DNS client.
You can configure other settings in "System > DNS".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
128
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● SMTP Client
Enable or disable the SMTP client. You can configure other settings in "System > SMTP
Client".
● Syslog Client
Enable or disable the Syslog client. You can configure other settings in "System > Syslog
Client".
● DCP Server
Specify whether or not the device can be accessed with DCP (Discovery and
Configuration Protocol):
– "-" (disabled)
DCP is disabled. Device parameters can neither be read nor modified.
– Read/Write
With DCP, device parameters can be both read and modified.
– Read Only
With DCP, device parameters can be read but cannot be modified.
● Time Setting
Select the setting from the drop-down list. The following settings are possible:
– Manual
The system time is set manually. You can configure other settings in "System >
System Time > Manual Setting".
– SIMATIC Time
The system time is set using a SIMATIC time transmitter. You can configure other
settings in "System > System Time > SIMATIC Time Client".
– SNTP Client
The system time is set via an SNTP server. You can configure other settings in
"System > System Time > SNTP Client".
– NTP Client
The system time is set via an NTP server. You can configure other settings in "System
> System Time > NTP Client".
– PTP Client(SCALANCE XR528-6M and XR552-12M only)
The system time is set via a PTP. You can configure other settings in "System >
System Time > PTP Client".
● SNMP
Select the protocol from the drop-down list. The following settings are possible:
– "-" (SNMP disabled)
Access to device parameters via SNMP is not possible.
– SNMPv1/v2c/v3
Access to device parameters is possible with SNMP versions 1, 2c or 3. You can
configure other settings in "System > SNMP > General".
– SNMPv3
Access to device parameters is possible only with SNMP version 3. You can configure
other settings in "System > SNMP > General".
● SNMPv1/v2 Read-Only
Enable or disable write access to SNMP variables with SNMPv1/v2c.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
129
Configuring with Web Based Management
5.4 The "System" menu
● SNMPv1 Traps
Enable or disable the sending of traps (alarm frames). You can configure other settings in
"System > SNMP > Traps".
● SINEMA configuration interface
If the SINEMA configuration interface is enabled, you can download configurations to the
IE switch via the TIA Portal.
● NFC(only for SCALANCE XM-400)
Activate or deactivate the "NFC" (Near Field Communication) function.
You will find further information on NFC in the "SCALANCE XM400" Operating
Instructions.
● Configuration Mode
Select the mode from the drop-down list. The following modes are possible:
– Automatic Save
Automatic backup mode. Approximately 1 minute after the last parameter change or
when you restart the device, the configuration is automatically saved.
– Trial
Trial mode. In Trial mode, although changes are adopted, they are not saved in the
configuration file (startup configuration).
To save changes in the configuration file, use the "Write startup config" button. The
"Write startup config" button is displayed when you set trial mode. The display area
also shows the message "Trial Mode Active – Press "Write Startup Config" button to
make your settings persistent" as soon as there are unsaved modifications. This
message can be seen on every WBM page until the changes made have either been
saved or the device has been restarted.
Steps in configuration
1. To use the required function, select the corresponding check box.
2. Select the options you require from the drop-down lists.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
130
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.2
General
5.4.2.1
Device
General device information
This page contains the general device information.
The boxes "Current System Time", "System Up Time" and "Device Type" cannot be
changed.
Description
The page contains the following boxes:
● Current System Time
Shows the current system time. The system time is either set by the user or by a time-ofday frame: either SINEC H1 time-of-day frame, NTP or SNTP. (readonly)
● System Up Time
Shows the operating time of the device since the last restart. (readonly)
● Device Type
Shows the type designation of the device. (readonly)
●
System Name
You can enter the name of the device. The entered name is displayed in the selection
area. A maximum of 255 characters are possible.
The system name is also displayed in the CLI input prompt. The number of characters in
the CLI input prompt is limited. The system name is truncated after 16 characters.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
131
Configuring with Web Based Management
5.4 The "System" menu
● System Contact
You can enter the name of a contact person responsible for managing the device. A
maximum of 255 characters are possible.
● System Location
You can enter the location where the device is installed. The entered installation location
is displayed in the selection area. A maximum of 255 characters are possible.
Note
The ASCII code 0x20 to 0x7e is used in the input boxes.
At the start and end of the boxes"System name", "System Contact" and "System
Location", the characters "<", ">" and "space" are not permitted.
Procedure
1. Enter the contact person responsible for the device in the "System Contact" input box.
2. Enter the identifier for the location at which the device is installed in the "System
Location" input box.
3. Enter the name of the device in the "System Name" input box.
4. Click the "Set Values" button.
5.4.2.2
Coordinates
Information on geographic coordinates
In the "Geographic Coordinates" window, you can enter information on the geographic
coordinates. The parameters of the geographic coordinates (latitude, longitude and the
height above the ellipsoid according to WGS84) are entered directly in the input boxes of the
"Geographic Coordinates" window.
Getting the coordinates
Use suitable maps for obtaining the geographic coordinates of the device.
The geographic coordinates can also be obtained using a GPS receiver. The geographic
coordinates of these devices are normally displayed directly and only need to be entered in
the input boxes of this page.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
132
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description
The page contains the following boxes. These are purely information boxes with a maximum
length of 32 characters.
● "Latitude" input box
Geographical latitude: Here, enter the value for the northerly or southerly latitude of the
location of the device.
For example, the value +49° 1´31.67" means that the device is located at 49 degrees, 1
arc minute and 31.67 arc seconds northerly latitude.
A southerly latitude is shown by a preceding minus character.
You can also append the letters N (northerly latitude) or S (southerly latitude) to the
numeric information (49° 1´31.67" N).
● "Longitude" input box
Geographic longitude: Here, you enter the value of the eastern or western longitude of
the location of the device.
The value +8° 20´58.73" means that the device is located at 8 degrees, 20 minutes and
58.73 seconds east.
A western longitude is indicated by a preceding minus sign.
You can also add the letter E (easterly longitude) or W (westerly longitude) to the numeric
information (8° 20´58.73" E).
● Input box: "Height"
Height Here, you enter the value of the geographic height above sea level in meters.
For example, 158 m means that the device is located at a height of 158 m above sea
level.
Heights below sea level (for example the Dead Sea) are indicated by a preceding minus
sign.
Procedure
1. Enter the calculated latitude in the "Latitude" input box.
2. Enter the calculated longitude in the "Longitude" input box.
3. Enter the height above sea level in the "Height" input box.
4. Click the "Set Values" button.
5.4.3
Agent IP
Here, you specify the IP configuration for the device.
With devices with more than one IP interface, this call references the "Subnets >
Configuration" menu item in the "Layer 3" menu and the configuration of the TIA interface
there.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
133
Configuring with Web Based Management
5.4 The "System" menu
5.4.4
DNS
On this page, you can configure up to 3 DNS servers. If there is more than one server, the
order in the table specifies the order in which the servers are queried. The top server is
queried first.
The DNS () server (Domain Name System) assigns a domain name to an IP address so that
a device can be uniquely identified.
If this function is enabled, the IE switch can communicate with a DNS server as a DNS
client. You have the option of entering names in IP address boxes.
Note
The DNS client function can only be used if there is a DNS server in the network.
Description
Figure 5-7
DNS client
SCALANCE XM-400/XR-500 Web Based Management (WBM)
134
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
The page contains the following boxes:
● DNS Client
Enable or disable depending on whether the IE switch should operate as a DNS client.
● Used DNS Servers
Here you specify which DNS server the device uses:
– learned only
The device uses only the DNS servers assigned by DHCP.
– manual only
The device uses only the manually configured DNS servers. The DNS servers must
be connected to the Internet. A maximum of three DNS servers can be configured.
– all
The device uses all available DNS servers.
● DNS Server Address
Enter the IP address of the DNS server.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● DNS Server Address
Shows the IP address of the DNS server.
● Origin
This shows whether the DNS server was configured manually or was assigned by DHCP.
Procedure
Activating DNS
1. Enable the "DNS-Client" check box.
2. Click the "Set Values" button.
Creating a DNS server
1. In the "DNS Server Address" box, enter the IP address of the DNS server.
2. Click the "Create" button.
Filtering DNS servers
1. In the "Used DNS Servers" drop-down list, select which DNS servers are to be used.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
135
Configuring with Web Based Management
5.4 The "System" menu
5.4.5
Restart
Resetting to the defaults
In this menu, there is a button with which you can restart the device and the option of
resetting to the factory settings.
Note
Note the following points about restarting a device:
• You can only restart the device with administrator privileges.
• A device should only be restarted with the buttons of this menu or with the appropriate
CLI commands and not by a power cycle on the device.
• Any modifications you have made only become active on the device after clicking the "Set
Values" button on the relevant WBM page. If the device is in "Trial Mode", configuration
modifications must be saved manually before a restart. In "Autosave mode", the last
changes are saved automatically before a restart.
Description of the displayed boxes
To restart the device, the buttons on this page provide you with the following options:
● "Neustart" button
Click this button to restart the system. You must confirm the restart in a dialog box.
During a restart, the device is reinitialized, the internal firmware is reloaded, and the
device runs a self-test. The learned entries in the address table are deleted. You can
leave the browser window open while the device restarts. You then need to log in again.
● "Restore Factory Defaults and Resart" button
Click this button to restore the factory defaults for the configuration. The protected
defaults are also reset.
An automatic restart is triggered.
NOTICE
By resetting all the defaults to the factory settings, the IP address and the passwords
are also lost. Following this, the device can only be accessed via the serial interface,
using the Primary Setup Tool or using DHCP.
With the appropriate attachment, a previously correctly configured device can cause
circulating frames and therefore the failure of the data traffic.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
136
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.6
Load & Save
Overview of the file types
5.4.6.1
File type
Description
Config
Start configuration
ConfigPack
Detailed configuration information. for example, start configuration, users,
certificates
Debug
This file contains information for Siemens Support.
Firmware
Firmware
GSDML
Information on the device properties
HTTPSCert
HTTPS certificate
LogFile
File with entries from the event log table
MIB
Private MSPS MIB file "Scalance_w_msps.mib"
RunningCLI
This file contains an overview of the current configuration in the form of CLI
commands. You can download the text file. The file is not intended to be uploaded again unchanged.
Script
CLI script file
StartupInfo
Startup log file
Users
File with user names and passwords
HTTP
Loading and saving data via HTTP
The WBM allows you to store device data in an external file on your client PC or to load such
data from an external file from the client PC to the devices. This means, for example, that
you can also load new firmware from a file located on your client PC.
Note
This WBM page is available both for connections using HTTP and for connections using
HTTPS.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
137
Configuring with Web Based Management
5.4 The "System" menu
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
Note
Incompatibility with previous firmware versions with/without PLUG inserted
During the installation of a previous version, the configuration data can be lost. In this case,
the device starts up with the factory settings after the firmware has been installed.
In this situation, if a PLUG is inserted in the device, following the restart, this has the status
"Not Accepted" since the PLUG still has the configuration data of the previous more up-todate firmware. This allows you to return to the previous, more up-to-date firmware without
any loss of configuration data. If the original configuration on the PLUG is no longer required,
the PLUG can be deleted or rewritten manually using the WBM page "System > PLUG".
Configuration files
Note
Configuration files and trial mode/Automatic Save mode
In Automatic Save mode, the data is saved automatically before the configuration files
(ConfigPack and Config) are transferred.
In Trial mode, although the changes are adopted, they are not saved in the configuration
files (ConfigPack and Config). Use the "Write Startup Config" button on the "System >
Configuration" WBM page to save changes in the configuration files.
CLI script file
You can download existing CLI configurations (RunningCLI) and upload your own CLI scripts
(Script).
Note
The downloadable CLI script is not intended to be uploaded again unchanged.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
138
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The table has the following columns:
● Type
Shows the file type.
● Description
Shows the short description of the file type.
● Load
With this button, you can upload files to the device. The button can be enabled, if this
function is supported by the file type.
● Save
With this button, you can download files from the device. The button can only be enabled
if this function is supported by the file type and the file exists on the device.
● Delete
With this button, you can delete files from the device. The button can only be enabled if
this function is supported by the file type and the file exists on the device.
Note
Following a firmware update, delete the cache of your Internet browser.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
139
Configuring with Web Based Management
5.4 The "System" menu
Steps in configuration
Uploading files using HTTP
1. Start the upload function by clicking the one of the "Load" buttons.
A dialog for uploading a file opens.
2. Select the required file and confirm the upload.
The file is uploaded.
3. If a restart is necessary, a message to this effect will be output. Click the "OK" button and
a restart will follow. If you click the "Abort" button, there is no device restart. The changes
only take effect after a restart.
Downloading files using HTTP
1. Start the download by clicking the one of the "Save" buttons.
2. Select a storage location and a name for the file.
3. Save the file.
The file is downloaded and saved.
Deleting files using HTTP
1. Start the delete function by clicking the one of the "Delete" buttons.
The file is deleted.
Reusing configuration data
If several devices are to receive the same configuration and the IP addresses are assigned
using DHCP, the effort for configuration can be reduced by saving and reading in the
configuration data.
Follow the steps below to reuse configuration data:
1. Save the configuration data of a configured device on your PC.
2. Load this configuration file on all other devices you want to configure in this way.
3. If individual settings are necessary for specific devices, these must be made online on the
relevant device.
Note
Configuration data has a checksum. If you edit the files, you can no longer upload them to
the IE switch.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
140
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.6.2
TFTP
Loading and saving data via a TFTP server
On this page, you can configure the TFTP server and the file names. The WBM also allows
you to store device data in an external file on a TFTP server or to load such data from an
external file from the TFTP server to the devices. This means, for example, that you can also
load new firmware from a file located on a TFTP server.
Firmware
The firmware is signed and encrypted. This ensures that only firmware created by Siemens
can be downloaded to the device.
Note
Incompatibility with previous firmware versions with/without PLUG inserted
During the installation of a previous version, the configuration data can be lost. In this case,
the device starts up with the factory settings after the firmware has been installed.
In this situation, if a PLUG is inserted in the device, following the restart, this has the status
"Not Accepted" since the PLUG still has the configuration data of the previous more up-todate firmware. This allows you to return to the previous, more up-to-date firmware without
any loss of configuration data. If the original configuration on the PLUG is no longer required,
the PLUG can be deleted or rewritten manually using the WBM page "System > PLUG".
Configuration files
Note
Configuration files and trial mode/Automatic Save mode
In Automatic Save mode, the data is saved automatically before the configuration files
(ConfigPack and Config) are transferred.
In Trial mode, although the changes are adopted, they are not saved in the configuration
files (ConfigPack and Config). Use the "Write Startup Config" button on the "System >
Configuration" WBM page to save changes in the configuration files.
CLI script file
You can download existing CLI configurations (RunningCLI) and upload your own CLI scripts
(Script).
Note
The downloadable CLI script is not intended to be uploaded again unchanged.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
141
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The page contains the following boxes:
● TFTP Server Address
Here, enter the IP address or the FQDN (Fully Qualified Domain Name) of the TFTP
server with which you exchange data.
● "TFTP Server Port"
Here, enter the port of the TFTP server over which data exchange will be handled. If
necessary, you can change the default value 69 to your own requirements.
The table has the following columns:
● Type
Shows the file type.
● Description
Shows the short description of the file type.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
142
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Filename
A file name is preset here for every file type.
Note
Changing the file name
You can change the file name preset in this column. After clicking the "Set Values"
button, the changed name is saved on the device and can also be used with the
Command Line Interface.
● Actions
Select the action from the drop-down list. The selection depends on the selected file type,
for example you can only save the log file.
The following actions are possible:
– Save file
With this selection, you save a file on the TFTP server.
– Load file
With this selection, you load a file from the TFTP server.
Steps in configuration
Loading or saving data using TFTP
1. Enter the IP address or the FQDN of the TFTP server in the "TFTP Server Address" input
box.
2. Enter the server port of the TFTP server to be used in the in the "TFTP Server Port" input
box.
3. If applicable, enter the name of a file in which you want to save the data or take the data
from in the "File name" input box.
4. Select the action you want to execute from the "Actions" drop-down list.
5. Click the "Set Values" button to start the selected actions.
6. If a restart is necessary, a message to this effect will be output. Click the "OK" button and
a restart will follow. If you click the "Abort" button, there is no device restart. The changes
only take effect after a restart.
Reusing configuration data
If several devices are to receive the same configuration and the IP addresses are assigned
using DHCP, the effort for configuration can be reduced by saving and reading in the
configuration data.
Follow the steps below to reuse configuration data:
1. Save the configuration data of a configured device on your PC.
2. Load this configuration file on all other devices you want to configure in this way.
3. If individual settings are necessary for specific devices, these must be made online on the
relevant device.
Note that the configuration data is coded when it is saved. This means that you cannot edit
the files with a text editor.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
143
Configuring with Web Based Management
5.4 The "System" menu
5.4.6.3
Passwords
There are files to which access is password protected. To load the file on the device, enter
the password specified for the file on the WBM page.
Description
The table has the following columns:
● Type
Shows the file type.
● Description
Shows the short description of the file type.
● Enabled
When selected, the password is used. Can only be enabled if the password is configured.
● Password
Enter the password for the file.
● Password Confirmation
Confirm the password.
● Status
Shows whether the current settings for the file match the device.
– Valid
the "Enabled" check box is selected and the password matches the certificate.
– Invaalid
the "Enabled" check box is selected but the password does not match the certificate or
no certificate has been loaded yet.
– '-'
The password cannot be evaluated or is not yet being used. The "Enabled" check box
is not selected.
Procedure
1. Enter the password in "Password".
2. To confirm the password, enter the password again in "Password Confirmation".
3. Select the "Enabled" option.
4. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
144
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.7
Events
5.4.7.1
Configuration
Selecting system events
On this page, you specify how a device reacts to system events. By enabling the appropriate
options, you specify how the device reacts to events. To enable or disable the options, click
the relevant check boxes of the columns.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
145
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The page contains the following boxes:
● "Signaling Contact Method" drop-down list
Select the reaction of the signaling contact from the drop-down list. The following
reactions are possible:
– conventional
Default setting for the signaling contact. An error/fault is displayed by the fault LED
and the signaling contact is opened. When the error/fault state no longer exists, the
fault LED goes off and the signaling contact is closed.
– User Defined
The way the signaling contact works does not depend on the error/fault that has
occurred. The signaling contact can be opened or closed as required by user actions.
● ""Signaling Contact Status" drop-down list
Select the status of the signaling contact from the drop-down list. The following states are
possible:
– Closed
Signaling contact is closed.
– Open
Signaling contact is opened.
The table has the following columns:
● E-Mail
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP client" function is enabled.
● Trap
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
● Log table
The device writes an entry in the event log table, see "Information > Log Table"
● Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
146
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Faults
The device triggers an error. The error LED lights up
● Event
The column contains the following values:
– Cold/Warm Start
The device was turned on or restarted by the user.
– Link Change
This event occurs only when the port status is monitored and has changed, see
"System > Fault Monitoring > Link Change".
– Authentication Failure
This event occurs when access is attempted with an incorrect password.
– RMON Alarm
An alarm or event has occurred relating to the remote monitoring of the system.
– Power Change
This event occurs only when power supply lines 1 and 2 are monitored. It indicates
that there was a change to line 1 or line 2. See "System > Fault Monitoring > Power
Supply".
– RM State Change
The redundancy manager has recognized an interruption or restoration of the ring and
has switched the line over or back.
– Spanning Tree Change
The STP or RSTP or MSTP topology has changed.
– Fault State Change
The fault status has changed. The fault status can relate to the activated port
monitoring, the response of the signaling contact or the power supply monitoring.
– Standby State Change
A device with an established standby connection (master or slave) has activated or
deactivated the link to the other ring (standby port). The data traffic was redirected
from one Ethernet connection (standby port of the master) to another Ethernet
connection (standby port of the slave).
– VRRP State Change (only when routing via VRRP)
The status of the virtual router has changed
– Loop Detection
A loop was detected in the network segment.
– OSPF State Change
The status of OSPF has changed.
– Pnac Port Authentication State Change
This event occurs with 802.1X authentications.
– PoE State Change
The status of PoE has changed.
– FMP Status Change
The value of the received power or the power loss has exceeded or fallen below a
certain limit.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
147
Configuring with Web Based Management
5.4 The "System" menu
Steps in configuration
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
– E-mail
– Trap
– Log Table
– Syslog
– Faults
2. Click the "Set Values" button.
5.4.7.2
Severity Filters
Setting the Severity Filters
On this page, set the threshold levels for sending system event notifications.
The first table column shows the client type for which you are making the settings:
● E-mail
Sending system event messages by e-mail
● Log Table
Entry of system events in the log table
● Syslog
Entry of system events in the Syslog file
Select the required level from the drop-down lists of the second table column.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
148
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
You can select from the following values:
● Critical
System events are processed as of the severity level "Critical".
● Warning
System events are processed as of the severity level "Warning".
● Info
System events are processed as of the severity level "Info".
Procedure
Follow the steps below to configure the required level:
1. Select the required values from the drop-down lists of the second table column after the
client types.
2. Click the "Set Values" button.
5.4.8
SMTP client
Network monitoring with e-mails
The device provides the option of automatically sending an e-mail if an alarm event occurs
(for example to the network administrator). The e-mail contains the identification of the
sending device, a description of the cause of the alarm in plain language, and a time stamp.
This allows centralized network monitoring to be set up for networks with few nodes based
on an e-mail system. When an e-mail error message is received, the WBM can be started by
the Internet browser using the identification of the sender to read out further diagnostics
information.
On this page, you can configure up to three SMTP servers and the corresponding e-mail
addresses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
149
Configuring with Web Based Management
5.4 The "System" menu
Description
The page contains the following boxes:
● SMTP Client
Enable or disable the SMTP client.
● Sender Email Address
Enter the name of the sender to be included in the e-mail, for example the device name.
This setting applies to all configured SMTP servers.
● Send Test Mail
Send a test e-mail to check your configuration.
● SMTP Port
Enter the port via which your SMTP server can be reached.
Factory settings: 25
This setting applies to all configured SMTP servers.
● SMTP Server Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the SMTP server.
This table contains the following columns:
● Select
Select the check box in a row to be deleted.
● SMTP Server Address
Shows the IP address or the FQDN (Fully Qualified Domain Name) of the SMTP server.
● Receiver Email Address
Enter the e-mail address to which the device sends an e-mail if a fault occurs.
Procedure
1. Enable the "SMTP Client" option.
2. Enter the IP address of the SMTP server or the FQDN in the "SMTP Server Address"
input box.
3. Click the "Create" button. A new entry is generated in the table.
4. In the Receiver Email Address input box. enter the e-mail address to which the device
sends an e-mail if a fault occurs.
5. Click the "Set Values" button.
Note
Depending on the properties and configuration of the SMTP server, it may be necessary
to adapt the "Sender E-Mail Address” input box for the e-mails. Check with the
administrator of the SMTP server.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
150
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.9
DHCP client
Setting the DHCP mode
If the DHCP mode is activated, the DHCP client starts a DHCP request to a configured
DHCP server and is assigned an IPv4 address as the response. The server manages an
address range from which it assigns IPv4 addresses. It is also possible to configure the
server so that the client always receives the same IPv4 address in response to its request.
Description
The page contains the following boxes:
● "DHCP client configuration request (opt. 66, 67)"
Enable this option if you want the DHCP client to use options 66 and 67 to download and
then enable a configuration file.
● DHCP Mode
Select the DHCP mode from the drop-down list. The following modes are possible:
– via MAC Address
Identification is based on the MAC address.
– via DHCP Client ID
Identification is based on a freely defined DHCP client ID.
– Via System Name
Identification is based on the system name. If the system name is 255 characters long,
the last character is not used for identification.
– via PNIO Name of Station
identification is based on the PNIO name of the station.
The table has the following columns:
● Interface
Interface to which the setting relates.
● DHCP
Enable or disable the DHCP client for the relevant interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
151
Configuring with Web Based Management
5.4 The "System" menu
Procedure
Follow the steps below to configure the IP address using the DHCP client ID:
1. Enable the "DHCP Client" option.
2. Select the "via DHCP client ID" DHCP mode from the "DHCP Mode" drop-down list.
3. Enter a character string to identify the device in the enabled "DHCP Client ID" input box.
This is then evaluated by the DHCP server.
4. Select the "DHCP Client Configuration Request (Opt.66, 67)" option, if you want the
DHCP client to use options 66 and 67 to download and then enable a configuration file.
5. Click the "Set Values" button.
Note
If a configuration file is downloaded, this can trigger a system restart. If the currently
running configuration and the configuration in the downloaded configuration file differ, the
system is restarted.
Make sure that the option "DHCP Client Configuration Request (Opt.66, 67)" is no longer
set in this configuration file.
5.4.10
SNMP
5.4.10.1
General
Configuration of SNMP
On this page, you make the basic settings for SNMP. Enable the check boxes according to
the function you want to use.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
152
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description
The page contains the following boxes:
● SNMP
Select the SNMP protocol from the drop-down list. The following settings are possible:
– "-" (disabled)
SNMP is disabled.
– SNMPv1/v2c/v3
SNMPv1/v2c/v3 is supported.
– SNMPv3
Only SNMPv3 is supported.
● SNMPv1/v2c Read-Only
If you enable this option, SNMPv1/v2c can only read the SNMP variables.
Note
Community String
For security reasons, do not use the standard values "public" or "private". Change the
community strings following the initial installation.
● SNMPv1/v2c Read Community String
Enter the community string for read access of the SNMP protocol.
● SNMPv1/v2c Read/Write Community String
Enter the community string for read and write access of the SNMP protocol.
● SNMPv1 Traps
Enable or disable the sending of SNMP traps (alarm frames). On the "Trap" tab, specify
the IP addresses of the devices to which SNMP traps will be sent.
● SNMPv1/v2c Trap Community String
Enter the community string for sending SNMPv1/v2 messages.
Procedure
1. Select the required option from the "SNMP" drop-down list:
– "-" (disabled)
– SNMPv1/v2c/v3
– SNMPv3
2. Enable the "SNMPv1/v2c schreibgeschützt" check box if you only want read access to
SNMP variables with SNMPv1/v2c.
3. Enter the required character string in the "SNMPv1/v2c Read Community String" input
box.
4. Enter the required character string in the "SNMPv1/v2c Read/Write Community String"
input box.
5. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
153
Configuring with Web Based Management
5.4 The "System" menu
5.4.10.2
Traps
SNMP traps for alarm events
If an alarm event occurs, a device can send SNMP traps (alarm frames) to up to ten different
management stations at the same time. Traps are only sent if the events specified in the
"Events" menu occur.
Note
Traps are only sent if you have enabled the option "SNMPv1 Traps" in the "General" tab or
in "System > Configuration".
Description
● Trap Receiver Address
Enter the IP address or the FQDN name of the station to which the device sends SNMP
traps. You can specify up to ten different recipients servers.
The table has the following columns:
● Select
Select the row you want to delete.
● Trap Receiver Address
If necessary, change the IP addresses or the FQDN names of the stations.
● Trap
Enable or disable the sending of traps. Stations that are entered but not selected do not
receive SNMP traps.
Procedure
Creating a trap entry
1. In "Trap Receiver Address", enter the IP address or the FQDN name of the station to
which the device sends traps.
2. Click the "Create" button to create a new trap entry.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
154
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
3. Select the check box in the required row "Trap".
4. Click the "Set Values" button.
Deleting a trap entry
1. Enable "Select" in the row to be deleted.
2. Click the "Delete" button. The entry is deleted.
5.4.10.3
v3 Groups
Security settings and assigning permissions
SNMP version 3 allows permissions to be assigned, authentication, and encryption at
protocol level. The security levels and read/write permissions are assigned according to
groups. The settings automatically apply to every member of a group.
Description
The page contains the following boxes:
● Group Name
Enter the name of the group. The maximum length is 32 characters.
● Security Level
Select the security level (authentication, encryption) valid for
the selected group. In the security levels, the following options:
– no Auth/no Priv
No authentication enabled / no encryption enabled.
– Auth/no Priv
Authentication enabled / no encryption enabled.
– Auth/Priv
Authentication enabled / encryption enabled.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
155
Configuring with Web Based Management
5.4 The "System" menu
The table has the following columns:
● Select
Select the row you want to delete.
● Group Name
Shows the defined group names.
● Security Level
Shows the configured security level.
● Read
Enable or disable read access for the required group.
● Write
Enable or disable write access for the required group.
Note
For write access to work, you also need to enable read access.
● Persistence
Shows whether or not the group is assigned to an SNMPv3 user. If the group is not
assigned to an SNMPv3 user, no automatic saving is triggered and the configured group
disappears again after restarting the device.
– Yes
The group is assigned to an SNMPV3 user.
– No
The group is not assigned to an SNMPV3 user.
Procedure
Creating a new group
1. Enter the required group name in "Group Name".
2. Select the required security level from the "Security Level" drop-down list.
3. Click the "Create" button to create a new entry.
4. Specify the required read rights for the group in " Read".
5. Specify the required write rights for the group in " Write".
6. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
156
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Modifying a group
1. Specify the required read rights for the group in " Read".
2. Specify the required write rights for the group in " Write".
3. Click the "Set Values" button.
Note
Once a group name and the security level have been specified, they can no longer be
modified after the group is created. If you want to change the group name or the security
level , you will need to delete the group and recreate it and reconfigure it with the new
name.
Deleting a group
1. Enable "Select" in the row to be deleted.
Repeat this for all groups you want to delete.
2. Click the "Delete" button. The entries are deleted.
5.4.10.4
v3 users
User-specific security settings
On the WBM page, you can create new SNMPv3 users and modify or delete existing users.
The user-based security model works with the concept of the user name; in other words, a
user ID is added to every frame. This user name and the applicable security settings are
checked by both the sender and recipient.
Description
The page contains the following boxes:
● User Name
Enter a freely selectable user name. After you have entered the data, you can no longer
modify the name.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
157
Configuring with Web Based Management
5.4 The "System" menu
The table has the following columns:
● Select
Select the row you want to delete.
● User Name
Shows the created users.
● Group Name
Select the group which will be assigned to the user.
● Authentication Protocol
Specify the authentication protocol. Can only be enabled, if this group supports the
function.
The following settings are available:
– None
– MD5
– SHA
● Privacy Protocol
Specify whether or not the user uses the DES algorithm. Can only be enabled, if the
group supports this function.
● Authentication Password
Enter the authentication password in the first input box. This password must have at least
6 characters, the maximum length is 32 characters.
● Authentication Password Confirmation
Confirm the password by repeating the entry.
● Privacy Password
Enter your encryption password. This password must have at least 6 characters, the
maximum length is 32 characters.
● Privacy Password Confirmation
Confirm the encryption password by repeating the entry.
● Persistence
Shows whether or not the user is assigned to an SNMPv3 group. If the user is not
assigned to an SNMPv3 group, no automatic saving is triggered and the configured user
disappears again after restarting the device.
– Yes
The user is assigned to an SNMPv3 group.
– No
The user is not assigned to an SNMPv3 group.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
158
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Procedure
Create a new user
1. Enter the name of the new user in the "User Name" input box.
2. Click the "Create" button. A new entry is generated in the table.
3. In "Group Name", select the group to which the new user will belong.
If the group has not yet been created, change to the "v3 Groups" page and make the
settings for this group.
4. If an authentication is necessary for the selected group, select the authentication
algorithm in "Authentication Protocol".
In the relevant input boxes, enter the authentication password and its confirmation.
5. If encryption was specified for the group, select the algorithm in "Privacy Protocol". In the
relevant input boxes, enter the encryption password and the confirmation.
6. Click the "Set Values" button.
Delete user
1. Enable "Select" in the row to be deleted.
Repeat this for all users you want to delete.
2. Click the "Delete" button. The entry is deleted.
Note
If you click a different button prior to this step (for example the "Refresh" button), the
delete action is canceled. The data of the selected rows is retained. The selections are
removed. If you want to repeat the action, you will need to reselect the data records to be
deleted.
5.4.11
System Time
There are different methods that can be used to set the system time of the device. Only one
method can be active at any one time.
If one method is activated, the previously activated method is automatically deactivated.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
159
Configuring with Web Based Management
5.4 The "System" menu
5.4.11.1
Manual Setting
Manual setting of the system time
On this page, you set the date and time of the system yourself. For this setting to be used,
enable "Time Manually".
Description
The page contains the following boxes:
● Time Manually
Enable or disable the manual time setting. If you enable the option, the "System Time"
input box can be edited.
● System Time
Enter the date and time in the format "MM/DD/YYYY HH:MM:SS".
● Use PC Time
Click the button to use the time setting of the PC.
● Last Synchronization Time
Shows when the last time-of-day synchronization took place. If no time-of-day
synchronization was possible, the box displays "Date/time not set".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
160
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Last Synchronization Mechanism
Shows how the last time synchronization was performed.
– Not set
The time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
– PTP
Automatic time-of-day synchronization with PTP
● Daylight Saving Time (DST)
Shows whether the daylight saving time changeover is active.
– active (offset +1 h)
The system time was changed to daylight saving time; in other words an hour was
added. You can see the current system time at the top right in the selection area of the
WBM.
The set time continues to be displayed in the "System Time" box.
– inactive (offset +0 h)
The current system time is not changed.
Procedure
1. Enable the "Time Manually" option.
2. Click in the "System Time" input box.
3. In the "System Time" input box, enter the date and time in the format "MM/DD/YYYY
HH:MM:SS".
4. Click the "Set Values" button.
The date and time are adopted and "Manual" is entered in "Last Synchronization
Mechanism" box.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
161
Configuring with Web Based Management
5.4 The "System" menu
5.4.11.2
DST Overview
On this page, you can create new entries for the daylight saving time changeover.
The table provides an overview of the existing entries.
Settings
● Select
Select the row you want to delete.
● DST No.
Shows the number of the entry.
If you create a new entry, a new line with a unique number is created.
● Name
Shows the name of the entry.
● Year
Shows the year for which the entry was created.
● Start Date
Shows the month, day and time for the start of daylight saving time.
● End Date
Shows the month, day and time for the end of daylight saving time.
● Recurring Date
With an entry of the type "Rule", the period in which daylight saving time is active is
displayed consisting of week, day, month and time of day.
With an entry of the type "Date" a "-" is displayed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
162
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Status
Shows the status of the entry:
– enabled
The entry was created correctly.
– invalid
The entry was created new and the start and end date are identical.
● Type
Shows how the daylight saving time changeover is made:
– Date
A fixed date is entered for the daylight saving time changeover.
– Rule
A rule was defined for the daylight saving time changeover.
Procedure
Creating an entry
1. Click the "Create" button.
A new entry is created in the table.
2. Click on the required entry in the "DST No column.
You change to the "DST Configuration" page.
3. Select the required type in the "Type" drop-down list.
Depending on the selected type, various settings are available.
4. Enter a name name in the "Name" box.
5. If you have selected the type "Date", fill in the following boxes.
– Year
– Day (for start and end date)
– Hour (for start and end date)
– Month (for start and end date)
6. If you have selected the type "Rule", fill in the following boxes.
– Hour (for start and end date)
– Month (for start and end date)
– Week (for start and end date)
– Day (for start and end date)
7. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
163
Configuring with Web Based Management
5.4 The "System" menu
Deleting an entry
1. Enable "Select" in the row to be deleted.
2. Click the "Delete" button. The entry is deleted.
5.4.11.3
DST Configuration
On this page, you can configure the entries for the daylight saving time changeover. As
result of the changeover to daylight saving or standard time, the system time for the local
time zone is correctly set.
You can define a rule for the daylight saving time changeover or specify a fixed date.
Settings
Note
The content of this page depends on the selection in the "Type" box.
The boxes "DST No.", "Type" and "Name" are always shown.
● DST No.
Select the type of the entry.
● Type
Select how the daylight saving time changeover is made:
– Date
You can set a fixed date for the daylight saving time changeover.
This setting is suitable for regions in which the daylight saving time changeover is not
governed by rules.
– Rule
You can define a rule for the daylight saving time changeover.
This setting is suitable for regions in which the daylight saving time always begins or
ends on a certain weekday.
● Name
Enter a name for the entry.
The name can be a maximum of 16 characters long.
Settings with "Date"selected
SCALANCE XM-400/XR-500 Web Based Management (WBM)
164
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
You can set a fixed date for the start and end of daylight saving time.
● Year
Enter the year for the daylight saving time changeover.
● Start Date
Enter the following values for the start of daylight saving time:
– Day
Specify the day.
– Hour
Specify the hour.
– Month
Specify the month.
● End Date
Enter the following values for the end of daylight saving time:
– Day
Specify the day.
– Hour
Specify the hour.
– Month
Specify the month.
Settings with "Rule" selected
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
165
Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XM-400/XR-500 Web Based Management (WBM)
166
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
You can create a rule for the daylight saving time changeover.
● Year
Enter the year for the daylight saving time changeover.
● Start Date
Enter the following values for the start of daylight saving time:
– Hour
Specify the hour.
– Month
Specify the month.
– Week
Specify the week.
You can select the first to fourth or the last week of the month.
– Weekday
Specify the weekday.
● End Date
Enter the following values for the end of daylight saving time:
– Hour
Specify the hour.
– Month
Specify the month.
– Week
Specify the week.
You can select the first to fourth or the last week of the month.
– Weekday
Specify the weekday.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
167
Configuring with Web Based Management
5.4 The "System" menu
5.4.11.4
SNTP Client
Time-of-day synchronization in the network
SNTP (Simple Network Time Protocol) is used for synchronizing the time in the network. The
time frames are sent by an SNTP server in the network.
Description
The page contains the following boxes:
● SNTP Client
Enable or disable automatic time-of-day synchronization using SNTP.
● Current System Time
Shows the current date and current normal time received by the IE switch. If you specify
a time zone, the time information is adapted accordingly.
● Last Synchronization Time
Shows when the last time-of-day synchronization took place.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
168
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
– Not set
The time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
– PTP
Automatic time-of-day synchronization with PTP
● Time Zone
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time.
The time in the "Current System Time" box is adapted accordingly.
● Daylight Saving Time (DST)
Shows whether the daylight saving time changeover is active.
– active (offset +1 h)
The system time was changed to daylight saving time; in other words an hour was
added. You can see the current system time at the top right in the selection area of the
WBM.
The normal time including the time zone continues to be displayed in the "Current
System Time" box.
– inactive (offset +0 h)
The current system time is not changed.
● "SNTP Mode"
Select the synchronization mode from the drop-down list. The following types of
synchronization are possible:
– Poll
If you select this protocol type, the input boxes "SNTP Server Address", "SNTP Server
Port and "Poll Interval[s]" are displayed to allow further configuration. With this type of
synchronization, the device is active and sends a time query to the SNTP server.
– Listen
With this type of synchronization, the device is passive and receives SNTP frames
that deliver the time of day.
● SNTP Server Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the SNTP server.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
169
Configuring with Web Based Management
5.4 The "System" menu
● SNTP Server Port
Enter the port of the SNTP server.
The following ports are possible:
– 123 (standard port)
– 1025 to 36564
● Poll Interval[s]
Here, enter the interval between two-time queries. In this box, you enter the query interval
in seconds. Possible values are 16 to 16284 seconds.
Procedure
1. Click the "SNTP Client" check box to enable the automatic time setting.
2. In the "Time Zone" input box, enter the local time difference to world time (UTC). The
input format is "+/-HH:MM" (for example +02:00 for CEST), because the SNTP server
always sends the UTC time. This time is then recalculated and displayed as the local time
based on the specified time zone. On the device itself, there is no changeover from the
daylight saving to standard time. You also need to take this into account when completing
the "Time Zone" input box.
3. Select one of the following options from the "SNTP Mode" drop-down list:
– Poll
For this mode, you need to configure the following:
- time zone difference (step 2)
- time server (step 4)
- Port (step 5)
- query interval (step 6)
- complete the configuration with step 7.
– Listen
For this mode, you need to configure the following:
- time difference to the time sent by the server (step 2)
- complete the configuration with step 7.
4. In the "SNTP Server Address" input box, enter the IPv4 address or the FQDN of the
SNTP server whose frames will be used to synchronize the time of day.
5. In the "SNTP Server Port" input box, enter the port via which the SNTP server is
available. The port can only be modified if the IPv4 address or the FQDN name of the
SNTP server is entered.
6. In the "Poll Interval[s]" input box, enter the time in seconds after which a new time query
is sent to the time server.
7. Click the "Set Values" button to transfer your changes to the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
170
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.11.5
NTP Client
Automatic time-of-day setting with NTP
If you require time-of-day synchronization using NTP, you can make the relevant settings
here.
Description
The page contains the following boxes:
● NTP Client
Select this check box to enable automatic time-of-day synchronization with NTP.
● Current System Time
Shows the current date and current normal time received by the IE switch. If you specify
a time zone, the time information is adapted accordingly.
● Last Synchronization Time
Shows when the last time-of-day synchronization took place.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
171
Configuring with Web Based Management
5.4 The "System" menu
● Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
– Not set
The time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
– PTP
Automatic time-of-day synchronization with PTP
● Time Zone
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time.
The time in the "Current System Time" box is adapted accordingly.
● Daylight Saving Time (DST)
Shows whether the daylight saving time changeover is active.
– active (offset +1 h)
The system time was changed to daylight saving time; in other words an hour was
added. You can see the current system time at the top right in the selection area of the
WBM.
The normal time including the time zone continues to be displayed in the "Current
System Time" box.
– inactive (offset +0 h)
The current system time is not changed.
● NTP Server Address
Enter the IPv4 address or the FQDN (Fully Qualified Domain Name) of the NTP server.
● NTP Server Port
Enter the port of the NTP server.
The following ports are possible:
– 123 (standard port)
– 1025 to 36564
● Poll Interval[s]
Here, enter the interval between two-time queries. In this box, you enter the query interval
in seconds. Possible values are 64 to 1024 seconds.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
172
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Procedure
1. Click the "NTP Client" check box to enable the automatic time setting using NTP.
2. Enter the necessary values in the following boxes:
– Time zone
– IPv4 address or FQDN of the NTP server
– NTP server port
– Query interval
3. Click the "Set Values" button.
5.4.11.6
SIMATIC time client
Time setting via SIMATIC time client
Description
The page contains the following boxes:
● SIMATIC Time Client
Select this check box to enable the device as a SIMATIC time client.
● Current System Time
Shows the current system time.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
173
Configuring with Web Based Management
5.4 The "System" menu
● Last Synchronization Time
Shows when the last time-of-day synchronization took place.
● Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
– Not set
The time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
– PTP
Automatic time-of-day synchronization with PTP
Procedure
1. Click the "SIMATIC Time Client" check box to enable the SIMATIC Time Client.
2. Click the "Set Values" button.
5.4.11.7
PTP Client
The following devices support time-of-day synchronization using PTP:
● SCALANCE XR528-6M
● SCALANCE XR552-12M
5.4.11.8
PTP Client
Automatic time-of-day setting with PTP
If you require time-of-day synchronization using PTP, you can make the relevant settings
here.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
174
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description
The page contains the following boxes:
● PTP Client
Select this check box to enable automatic time-of-day synchronization with PTP.
● Current System Time
Shows the current date and current normal time obtained due to time synchronization in
the network. If you specify a time zone, the time information is adapted accordingly.
● Last Synchronization Time
Shows when the last time-of-day synchronization took place.
● Last Synchronization Mechanism
Shows how the last time synchronization was performed. The following methods are
possible:
– Not set
The time was not set.
– Manual
Manual time setting
– SNTP
Automatic time-of-day synchronization with SNTP
– NTP
Automatic time-of-day synchronization with NTP
– SIMATIC
Automatic time-of-day synchronization using the SIMATIC time frame
– PTP
Automatic time-of-day synchronization with PTP
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
175
Configuring with Web Based Management
5.4 The "System" menu
● Time Zone
In this box, enter the time zone you are using in the format "+/- HH:MM". The time zone
relates to UTC standard world time.
The time in the "Current System Time" box is adapted accordingly.
● Daylight Saving Time (DST)
Shows whether the daylight saving time changeover is active.
– active (offset +1 h)
The system time was changed to daylight saving time; in other words an hour was
added. You can see the current system time at the top right in the selection area of the
WBM.
The normal time including the time zone continues to be displayed in the "Current
System Time" box.
– inactive (offset +0 h)
The current system time is not changed.
Procedure
1. Click the "PTP Client" check box to enable the automatic time setting using PTP.
2. Specify the a time zone, if applicable.
3. Click the "Set Values" button.
5.4.12
Automatic logout
Setting the automatic logout
On this page, set the times after which there is an automatic logout from WBM or the CLI
following user in activity.
If you have been logged out automatically, you will need to log in again.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
176
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Configuration
1. Enter a value of 60-3600 seconds in the "Web Base Management [s]" input box. If you
enter the value 0, the automatic logout is disabled.
2. Enter a value of 60-600 seconds in the "CLI (TELNET, SSH, Serial) [s]" input box. If you
enter the value 0, the automatic logout is disabled.
3. Click the "Set Values" button.
5.4.13
Configuration of the SELECT/SET button
Description of the SELECT/SET button
The "SELECT/SET" button is used for the following:
● Changing the display mode,
● Resetting to factory defaults,
● Defining the fault mask and the LED display.
You will find a detailed description of the individual functions available with the buttons in the
device operating instructions.
On this page, the functionality of the SELECT/SET button can be restricted or fully disabled.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
177
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The following functions are possible:
● Restore Factory Defaults
Enable or disable the "Restore Factory Defaults" function with the Select/set button.
CAUTION
Button function "Restore Factory Defaults" active during startup
If you have disabled this function in your configuration, disabling is only valid during
operation. When restarting, for example after power down, the function is active until the
configuration is loaded so that the device can inadvertently be reset to the factory
settings. This may cause unwanted disruption in network operation since the device
needs to be reconfigured if this occurs. An inserted PLUG is also deleted and returned
to the status as shipped.
● Redundancy Manager
Enables/disables the redundancy manager function.
● Set Fault Mask
Enable or disable the function "Define fault mask via the LED display" with the
SELECT/SET button.
Steps in configuration
1. To use the required functionality, select the corresponding check box.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
178
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.14
Syslog Client
System event agent
Syslog according to RFC 3164 is used for transferring short, unencrypted text messages
over UDP in the IP network. This requires a Syslog server.
Requirements for sending log entries:
● The Syslog function is enabled on the device.
● The Syslog function is enabled for the relevant event.
● There is a Syslog server in your network that receives the log entries. (Since this is a
UDP connection, there is no acknowledgment to the sender)
● The IP address or the FQDN (Fully Qualified Domain Name) of the Syslog server is
entered in the device.
Description
The page contains the following boxes:
● Syslog Client
Enable or disable the Syslog function.
● Syslog Server Address
Enter the IP address or the FQDN (Fully Qualified Domain Name) of the Syslog server.
This table contains the following columns
● Select
Select the row you want to delete.
● Syslog Server Address
Shows the IP address or the FQDN (Fully Qualified Domain Name) of the Syslog server.
● Server Port
Enter the port of the Syslog server being used.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
179
Configuring with Web Based Management
5.4 The "System" menu
Procedure
Enabling function
1. Select the "Syslog Client" check box.
2. Click the "Set Values" button.
Creating a new entry
1. In the "Syslog Server Address" input box, enter the IP address or the FQDN of the Syslog
server on which the log entries will be saved.
2. Click the "Create" button. A new row is inserted in the table.
3. In the "Server Port" input box, enter the number of the UDP port of the server.
4. Click the "Set Values" button.
Note
The default setting of the server port is 514.
Changing the entry
1. Delete the entry.
2. Create a new entry.
Deleting an entry
1. Select the check box in the row to be deleted.
2. Click the "Delete" button. All selected entries are deleted and the display is refreshed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
180
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.15
Ports
5.4.15.1
Overview
Overview of the port configuration
The page shows the configuration for the data transfer for all ports of the device. You cannot
configure anything on this page.
Description of the displayed boxes
The table has the following columns:
● Port
Shows the configurable ports. The entry is a link. If you click on the link, the
corresponding configuration page is opened. The port is made up of the module number
and the port number, for example port 0.1 is module 0, port 1.
● Port name
Shows the name of the port.
● Port Type (only with routing)
Shows the type of the port. The following types are possible:
– Router port
– Switch Port VLAN Hybrid
– Switch-Port VLAN Trunk
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
181
Configuring with Web Based Management
5.4 The "System" menu
● Combo Port Media Type
This column contains a value only with combo ports.
Shows the mode of the combo port:
– auto
– rj45
– sfp
● Status
Shows whether the port is on or off. Data traffic is possible only over an enabled port.
● OperState
Displays the current operational status. The operational status depends on the configured
"Status" and the "Link". The available options are as follows:
– up
You have configured the status "enabled" for the port and the port has a valid
connection to the network.
– down
You have configured the status "disabled" or "Link down" for the port or the port has
no connection.
– not present
With modular devices, this status is displayed when, for example, no media module is
inserted.
● Link
Shows the connection status to the network. With the connection status, the following is
possible:
– up
The port has a valid link to the network, a link integrity signal is being received.
– down
The link is down, for example because the connected device is turned off.
● Curr. transfer mode
Shows the transfer parameters of the port.
● MTU (Maximum Transmission Unit)
Shows the packet size.
● Negotiation
Shows whether the automatic configuration is enabled or disabled.
● Flow Ctrl. Type
Shows whether flow control is enabled or disabled for the port.
● Flow Ctrl.
Shows whether flow control is working on this port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
182
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● MAC Address
Shows the MAC address of the port.
● Blocked by
Shows why the port is in the "blocked" status:
– The analysis of the port status Is not supported.
– forwarding
The port is not blocked.
– ring-redundancy
The port belongs to a redundancy manager. When the redundancy manager is in the
"Passive status, one of the ring ports is in the "blocking" status.
– spanning-tree
The port has the status "Discarding" in the spanning tree. The port is part of a
spanning tree, however it is located on a redundant path and is deactivated for data
traffic.
– loop detection
A loop was detected and as the reaction to a loop, the status "disable" was configured
for the port.
– down-in-bundle
The port is part of a link aggregation and was deactivated by LACP.
– la-loop-detection
The port is part of a link aggregation. A loop was detected and as the reaction to a
loop, the status "disable" was configured for the link aggregation.
– la-spanning-tree
The port is part of a link aggregation. Thelink aggregation was switched to the status
"Discarding" by the spanning tree.
– admin-down
The status "disabled" is configured for the port, see "System > Ports > Configuration".
– link down
The status "enabled" is configured for the port but there is no connection, see "System
> Ports > Configuration".
– power-down
The status "Lin down" is configured for the port, see "System > Ports > Configuration".
– standby
Standby redundancy is enabled on the device. The port is a standby port with the
status "Passive".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
183
Configuring with Web Based Management
5.4 The "System" menu
Deviating display of the transmission parameters with combo ports
In the connection status "down", the displayed transmission parameters do not match the
actual values of the combo port. In the connection status "up", the correct values are
displayed.
Initial situation
A pluggable transceiver is plugged into the combo port with the following settings:
● Combo Port Media Type: auto
● Status: enabled
● Link: down
Display of the transmission parameters
With 100 Mbps pluggable transceivers
● Actual response: Mode: 1G HD
● Expected response: Mode: 100M FD
With 1 Gbps pluggable transceivers
● Actual response: Mode: 1G HD
● Expected response: Mode: 1G FD
SCALANCE XM-400/XR-500 Web Based Management (WBM)
184
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.15.2
Configuration
Configuring ports
With this page, you can configure all the ports of the device.
Description of the displayed boxes
The table has the following rows:
● Port
Select the port to be configured from the drop-down list. The port is made up of the
module number and the port number, for example port 0.1 is module 0, port 1.
● Status
Specify whether the port is enabled or disabled.
– enabled
The port is enabled. Data traffic is possible only over an enabled port.
– disabled
The port is disabled but the connection remains.
– link down
The port is disabled and the connection to the partner device is terminated.
● Port Name
Enter a name for the port here.
● MAC Address
Shows the MAC address of the port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
185
Configuring with Web Based Management
5.4 The "System" menu
● "Mode Type
From this drop-down list, select the transmission speed and the transfer mode of the port.
If you set the mode to "Auto negotiation", these parameters are automatically negotiated
with the connected end device. This must also be in the "Autonegotiation" mode.
Note
Before the port and partner port can communicate with each other, the settings must
match at both ends.
Note
"Mode Type" with combo ports
To be able to set the "Mode Type" of a combo port, change the "Combo Port Media Type"
to "rj45".
If "auto" is set for the "Combo Port Media Type" and the RJ-45 port is used, you cannot
set the "Mode Type".
● "Mode
Shows the transmission speed and the transfer mode of the port. The transmission speed
can be 10 Mbps, 100 Mbps, 1000 Mbps or 10 Gbps. As the transmission mode, you can
configure full duplex (FD) or half duplex (HD).
● Negotiation
Shows whether the automatic configuration of the connection to the partner port is
enabled or disabled.
Note
Turning flow control on/off with autonegotiation
Flow control can only be enabled or disabled if the "autonegotiation" function is turned off.
The function cannot enabled again afterwards.
● Flow Ctrl. Type
Enable or disable flow control for the port.
● Flow Ctrl.
Shows whether flow control is working on this port.
● MTU
Enter the packet size.
● Port Type(only with routing)
Select the type of port from the drop-down list.
– Router port
The port is a layer 3 interface. It does not support layer 2 functions.
– Switch Port VLAN Hybrid
The port sends tagged and untagged frames. It is not automatically a member of a
VLAN.
– Switch-Port VLAN Trunk
The port only sends tagged frames and is automatically a member of all VLANs.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
186
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Combo Port Media Type
Specify the mode of the combo port:
– auto
If you select this mode, the SFP transceiver port has priority.
As soon as an SFP transceiver is plugged in, an existing connection at the fixed RJ-45
port is terminated. If no SFC transceiver is plugged in, a connection can be
established via the fixed RJ-45 port.
– rj45
If you select this mode, the fixed RJ-45 port is used regardless of the SFP transceiver
port.
If an SFP transceiver is plugged in, it is disabled and the power turned off.
– sfp
If you select this mode, the SFP transceiver port is used regardless of the built-in RJ45 port.
If an RJ-45 connection is established, it is terminated because the power of the RJ-45
port is turned off.
The factory setting for the combo ports is the auto mode.
● OperState
Displays the current operational status. The operational status depends on the configured
"Status" and the "Link". The available options are as follows:
– up
You have configured the status "enabled" for the port and the port has a valid
connection to the network.
– down
You have configured the status "disabled" or "Link down" for the port or the port has
no connection.
– not present
With modular devices, this status is displayed when, for example, no media module is
inserted.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
187
Configuring with Web Based Management
5.4 The "System" menu
● Link
Shows the connection status to the network. The available options are as follows:
– up
The port has a valid link to the network, a link integrity signal is being received.
– down
The link is down, for example because the connected device is turned off.
● Blocked by
Shows why the port is in the "blocked" status:
– The analysis of the port status Is not supported.
– forwarding
The port is not blocked.
– ring-redundancy
The port belongs to a redundancy manager. When the redundancy manager is in the
"Passive status, one of the ring ports is in the "blocking" status.
– spanning-tree
The port has the status "Discarding" in the spanning tree. The port is part of a
spanning tree, however it is located on a redundant path and is deactivated for data
traffic.
– loop detection
A loop was detected and as the reaction to a loop, the status "disable" was configured
for the port.
– down-in-bundle
The port is part of a link aggregation and was deactivated by LACP.
– la-loop-detection
The port is part of a link aggregation. A loop was detected and as the reaction to a
loop, the status "disable" was configured for the link aggregation.
– la-spanning-tree
The port is part of a link aggregation. Thelink aggregation was switched to the status
"Discarding" by the spanning tree.
– admin-down
The status "disabled" is configured for the port, see "System > Ports > Configuration".
– link down
The status "enabled" is configured for the port but there is no connection, see "System
> Ports > Configuration".
– power-down
The status "Lin down" is configured for the port, see "System > Ports > Configuration".
– standby
SCALANCE XM-400/XR-500 Web Based Management (WBM)
188
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Standby redundancy is enabled on the device. The port is a standby port with the
status "Passive".
Changing the port configuration
Click the appropriate box to change the configuration.
Note
Optical ports only work with the full duplex mode and at maximum transmission rate. As a
result, the following settings cannot be made for optical ports:
• Automatic configuration
• Transmission speed
• Transmission technique
Note
With various automatic functions, the device prevents or reduces the effect on other ports
and priority classes (Class of Service) if a port is overloaded. This can mean that frames are
discarded even when flow control is enabled.
Port overload occurs when the device receives more frames than it can send, for example as
the result of different transmission speeds.
Steps in configuration
1. Change the settings according to your configuration.
2. Click the "Set Values" button.
5.4.16
Fault Monitoring
5.4.16.1
Power Supply
Settings for monitoring the power supply
Configure whether or not the power supply should be monitored by the messaging system.
Depending on the hardware variant there are one or two power connectors (Line 1 / Line 2).
With a redundant power supply, configure the monitoring separately for each individual feedin line.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
189
Configuring with Web Based Management
5.4 The "System" menu
A fault is then signaled by the message system when there is no power on one of the
monitored lines (line 1 or line 2) or when the voltage is too low.
Note
You will find the permitted operating voltage limits in the compact operating instructions of
the device.
A fault causes the signaling contact to trigger and the fault LED on the device to light up and,
depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log
table.
Procedure
1. Click the check box in front of the line name you want to monitor to enable or disable the
monitoring function.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
190
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.16.2
Link Change
Configuration of fault monitoring of status changes on connections
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
If connection monitoring is enabled, an error is signaled
● when there should be a link on a port and this is missing.
● or when there should not be a link on a port and a link is detected.
A fault causes the signaling contact to trigger and the fault LED on the device to light up and,
depending on the configuration, can trigger a trap, an e-mail, or an entry in the event log
table.
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– "-" (disabled)
– Up
– Down
– No Change: The setting in table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
191
Configuring with Web Based Management
5.4 The "System" menu
Table 2 has the following columns:
● Port
Shows the available ports and link aggregations. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
● Setting
Select the setting from the drop-down list. You have the following options:
– Up
Error handling is triggered when the port changes to the active status.
(From "Link down" to "Link up")
– Down
Error handling is triggered when the port changes to the inactive status.
(From "Link up" to "Link down")
– "-" (disabled)
The error handling is not triggered.
Steps in configuration
Configure error monitoring for a port
1. From the relevant drop-down list, select the options of the slots / ports whose connection
status you want to monitor.
2. Click the "Set Values" button.
Configure error monitoring for all ports
1. Select the required setting from the drop-down list of the "Setting"column.
2. Click the "Copy to table" button. The setting is adopted for all ports of table 2.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
192
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.16.3
Redundancy
On this page, you configure whether or not an error message is triggered if there is a status
change on a network connection.
Setting
● Redundancy loss (HRP only)
Enable or disable connection monitoring. If the redundancy of the connection is lost, an
error is signaled.
5.4.17
PNIO
Settings for PROFINET IO
This page shows the PROFINET IO AR status and the device name.
Description of the displayed boxes
The page contains the following boxes:
● PNIO AR Status
This box shows the status of the PROFINET IO connection; in other words whether the
device is connected to a PROFINET IO controller "Online " or "Offline".
Here, online means that a connection to a PROFINET IO controller exists, that this has
downloaded its configuration data to the device and that the device can send status data
to the PROFINET IO controller. In this status known as "in data exchange", the
parameters set with the PROFINET IO controller cannot be configured.
● PNIO Name of Station
This box displays the PROFINET IO device name according to the configuration in HW
Config of STEP 7.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
193
Configuring with Web Based Management
5.4 The "System" menu
5.4.18
PLUG
5.4.18.1
Configuration
NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. If it is
detected that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted
in the device, the device changes to a defined error state following the restart.
Information about the configuration of the C-PLUG / KEY-PLUG
This page provides detailed information about the configuration stored on the C-PLUG or
KEY-PLUG. It is also possible to reset the PLUG to "factory defaults" or to load it with new
contents.
Note
The action is only executed after you click the "Set Values" button.
The action cannot be undone.
If you decide against executing the function after making your selection, click the "Refresh"
button. As a result the data of this page is read from the device again and the selection is
canceled.
Note
Incompatibility with previous versions with PLUG inserted
During the installation of a previous version, the configuration data can be lost. In this case,
the device starts up with the factory settings after the firmware has been installed. In this
situation, if a PLUG is inserted in the device, following the restart, this has the status "Not
Accepted" since the PLUG still has the configuration data of the previous more up-to-date
firmware. This allows you to return to the previous, more up-to-date firmware without any
loss of configuration data.
If the original configuration on the PLUG is no longer required, the PLUG can be deleted or
rewritten manually using "System > PLUG".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
194
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The table has the following rows:
● Status
Shows the status of the PLUG. The following are possible:
– ACCEPTED
There is a PLUG with a valid and suitable configuration in the device.
– NOT ACCEPTED
Invalid or incompatible configuration on the inserted PLUG.
– NOT PRESENT
There is no C-PLUG or KEY-PLUG inserted in the device.
– FACTORY
PLUG is inserted and does not contain a configuration. This status is also displayed
when the PLUG was formatted during operation.
– MISSING
There is no PLUG inserted. Functions are configured on the device for which a license
is required.
● Device Group
Shows the SIMATIC NET product line that used the C-PLUG or KEY-PLUG previously.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
195
Configuring with Web Based Management
5.4 The "System" menu
● Device Type
Shows the device type within the product line that used the C-PLUG or KEY-PLUG
previously.
● Configuration Revision
The version of the configuration structure. This information relates to the configuration
options supported by the device and has nothing to do with the concrete hardware
configuration. This revision information does not therefore change if you add or remove
additional components (modules or extenders), it can, however, change if you update the
firmware.
● File System
Displays the type of file system on the PLUG.
NOTICE
New file system UBI
As of firmware version 3.0, UBI is the standard file system for the C-PLUG or KEYPLUG. If a C-PLUG with the previous file system IECP is detected in such a device, this
C-PLUG will be formatted for the UBI file system and the data will be rewritten to the CPLUG.
This change in the file system also occurs following a firmware update to V3.0. A
downgrade to the previous version of the firmware then presents a problem. The
firmware can neither read nor write the C-PLUG or KEY-PLUG and it is not even
possible to "Erase PLUG to Factory Default".
● File System Size [bytes]
Shows the maximum storage capacity of the file system on the C-PLUG.
● File System Usage [bytes]
Displays the storage space in use in the file system of the C-PLUG.
● Info String
Shows additional information about the device that used the PLUG previously, for
example, order number, type designation, and the versions of the hardware and software.
The displayed software version corresponds to the version in which the configuration was
last changed. With the "NOT ACCEPTED" status, further information on the cause of the
problem is displayed.
● "Modify PLUG
Select the setting from the drop-down list. You have the following options for changing
the configuration on the C-PLUG or KEY-PLUG:
– Write Current Configuration to the PLUG
This option is available only if the status of the PLUG is "NOT ACCEPTED" or
"FACTORY".
The configuration in the internal flash memory of the device is copied to the PLUG.
– Erase PLUG to factory default
Deletes all data from the C-PLUG and triggers low-level formatting.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
196
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Steps in configuration
1. You can only make settings in this box if you are logged on as "Administrator". Here, you
decide how you want to change the content of the PLUG.
2. Select the required option from the "Modify PLUG" drop-down list.
3. Click the "Set Values" button.
5.4.18.2
License
NOTICE
Do not remove or insert a C-PLUG / KEY-PLUG during operation!
A PLUG may only be removed or inserted when the device is turned off.
The device checks whether or not a PLUG is present at one second intervals. If it is
detected that the PLUG was removed, there is a restart. If a valid KEY-PLUG was inserted
in the device, the device changes to a defined error state following the restart.
If the device was configured at some time with a PLUG, the device can no longer be used
without this PLUG. To be able to use the device again, reset the device to the factory
settings.
Note
Incompatibility with previous versions with PLUG inserted
During the installation of a previous version, the configuration data can be lost. In this case,
the device starts up with the factory settings after the firmware has been installed. In this
situation, if a PLUG is inserted in the device, following the restart, this has the status "Not
Accepted" since the PLUG still has the configuration data of the previous more up-to-date
firmware. This allows you to return to the previous, more up-to-date firmware without any
loss of configuration data.
If the original configuration on the PLUG is no longer required, the PLUG can be deleted or
rewritten manually using "System > PLUG".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
197
Configuring with Web Based Management
5.4 The "System" menu
Information about the license of the KEY-PLUG
A C-PLUG can only store the configuration of a device. In addition to the configuration, a
KEY-PLUG also contains a license that enables certain functions of your SIMATIC NET
device.
This page provides detailed information about the license on the KEY-PLUG. In this
example, the KEY-PLUG contains the data for enabling the layer 3 functions of the device.
Description of the displayed boxes
● Status
Shows the status of the KEY-PLUG. The following are possible:
– ACCEPTED
The KEY-PLUG in the device contains a suitable and valid license.
– NOT ACCEPTED
The license of the inserted KEY-PLUG is not valid.
– NOT PRESENT
No KEY-PLUG is inserted in the device.
– MISSING
There is no KEY-PLUG or a C-PLUG with the status "FACTORY" inserted in the
device. Functions are configured on the device for which a license is required.
– WRONG
The inserted KEY-PLUG is not suitable for the device.
– UNKNOWN
Unknown content of the KEY-PLUG.
– DEFECTIVE
The content of the KEY-PLUG contains errors.
● Order ID
Shows the order number of the KEY-PLUG. The KEY-PLUG is available for various
functional enhancements and for various target systems.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
198
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Serial Number
Shows the serial number of the KEY-PLUG.
● Info String
Shows additional information about the device that used the KEY-PLUG previously, for
example, order number, type designation, and the versions of the hardware and software.
The displayed software version corresponds to the version in which the configuration was
last changed. With the "NOT ACCEPTED" status, further information on the cause of the
problem is displayed.
Note
When you save the configuration, the information about whether or not a KEY-PLUG was
inserted in the device at the time is also saved. This configuration can then only work if a
KEY-PLUG with the same order number / license is inserted.
5.4.19
Ping
Reachability of an address in an IPv4 network
With the ping function, you can check whether a certain IPv4 address is reachable in the
network.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
199
Configuring with Web Based Management
5.4 The "System" menu
Description
The table has the following columns:
● IP Address
Enter the IPv4 address of the device.
● Repeat
Enter the number of ping requests.
● Ping
Click this button to start the ping function.
● Ping Output
This box shows the output of the ping function.
● Clear
Click this button to empty the "Ping Output" box.
5.4.20
PoE
Note
The "PoE" menu item is only displayed with devices that support PoE.
5.4.20.1
General
Settings for Power over Ethernet (PoE)
On this page, you see information about the power that the IE switch supplies with PoE.
The SCALANCE XR-500 represents a PSE (Power Sourcing Equipment). With the
SCALANCE XM-400, each group of four ports with PoE capability is known as a PSE. The
displayed values apply only to the corresponding PSE.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
200
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
● PSE (read-only)
Shows the number of the PSE.
● Maximum Power [W] (read-only)
Maximum power that a PSE provides to supply PoE devices.
The "Maximum Power" value can be set for a SCALANCE XM-400.
● Allocated Power [W] (read-only)
Sum of the power reserved by the PoE devices according to the "Classification".
● Power in Use [W] (read-only)
Sum of the power used by the end devices.
● Usage Threshold [%]
As soon as the power being used by the end devices exceeds the percentage shown
here, an event is triggered.
Power over Ethernet with SCALANCE XM-400
With a SCALANCE XM-400, you can use the "Power over Ethernet" function via the port
extender PE408PoE.
PoE power supply
The connection of the PoE power supply is external. You can connect 2 PoE power supplies
with each PE408PoE port extender. Each PE408PoE therefore has 2 PSE units (Power
Sourcing Equipment) each with 4 ports.
Numbering of the PSE units
To be able to differentiate between the PSE units in the configuration, they are numbered:
Figure 5-8
SCALANCE XM-400 with 2 PE408PoE port extenders
If a PE408PoE is inserted in slot 2, its two PSE slots have indexes 1 and 2. If a PE408PoE is
inserted in slot 3, its two PSE slots have indexes 3 and 4.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
201
Configuring with Web Based Management
5.4 The "System" menu
The numbering of the PSE units is decided by the slots. If there is a port extender without
PoE in slot 2, and there is a PE408PoE in slot 3, the PSE units in slot 3 still have the indexes
3 and 4.
Figure 5-9
SCALANCE XM-400 with 2 port extenders (1 port extender without PoE and 1
PE408PoE)
With a SCALANCE XM416-4C with which you can only connect one port extender, the
indexes of the PSE units are 1 and 2.
Power over Ethernet with SCALANCE XR528-6M and SCALANCE XR552-12M
With SCALANCE XR528-6M and SCALANCE XR552-12M only the module slots 1 to 3 can
be fitted with PoE modules.
5.4.20.2
Port
Settings for the ports
For each individual PoE port, you can specify whether or not the power will be supplied via
Ethernet. You can also set a priority for each connected powered device (PD). Devices for
which a high priority was set, take preference over other devices for the power supply.
On this page, you can see detailed information on the individual PoE ports.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
202
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
Description of the displayed boxes
The page contains two tables. In table 1, you can make settings and assign them to all ports
at the same time. In table 2, you can make different settings for each port.
Table 1 has the following columns:
● Port
Shows that the settings are valid for all ports.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
Enables the function
– disabled
Disables the function
– No Change
The setting in table 2 remains unchanged
● Priority
Select the priority of the ports from the drop-down list. If you set the priority in table 1 and
copy the values to table 2, all ports will have the same priority.
The following settings are possible, in ascending order of relevance:
– low
low priority
– high
medium priority
– critical
high priority
– No Change
The setting in table 2 remains unchanged
● Type
Here, you can enter a string to describe the connected device in greater detail. The
maximum length is 255 characters.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
203
Configuring with Web Based Management
5.4 The "System" menu
Table 2 has the following columns:
● Port
Shows the configurable PoE ports.
The port is made up of the module number and the port number, for example port 0.1 is
module 0, port 1.
● Setting
Enable the PoE power supply for this port or interrupt it.
● Priority
From the drop-down list, select which priority this port will have for the power supply.
The following settings are possible, in ascending order of relevance:
– low
– high
– critical
If the same priority is set for two ports, the port with the lower number will be preferred
when necessary.
● Type
Here, you can enter a string to describe the connected device in greater detail. The
maximum length is 255 characters.
● Use Custom Maximum Power
If you enable this check box for a port, the user-defined maximum power is used.
● Custom Maximum power [W] (read-only)
Enter the maximum power that a port makes available to supply a connected device.
This value is only taken into account when the "Use Custom Maximum Power" check box
is selected.
● Classification (read-only)
The classification specifies the class of the device. From this, it is possible to recognize
the maximum power of the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
204
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
● Status (read-only)
Shows the current status of the port.
The following states are possible:
– disabled
The PoE power supply is deactivated for this port.
– delivering Power
The PoE power supply is activated for this port and a device is connected.
– searching
The PoE power supply is activated for this port but there is no device connected.
Note
If a device is connected to a port with PoE capability, a check is made to determine
whether the power of the port is adequate for the connected device.
If the power of the port is inadequate, although PoE is enabled in "Setting ", the port
nevertheless has the status "disabled". This means that the port was disabled by the PoE
power management.
● Power [mW] (read-only)
Shows the power that the SCALANCE provides for this port.
● Voltage [V] (read-only)
Shows the voltage applied to this port.
● Current [mA] (read-only)
Shows the current with which a device connected to this port is supplied.
5.4.21
Port Diagnostics
5.4.21.1
Cable Tester
With this page, each individual Ethernet port can run independent fault diagnostics on the
cable. This test is performed without needing to remove the cable, connect a cable tester
and install a loopback module at the other end. Short-circuits and cable breaks can be
localized to within a few meters.
Note
Please note that this test is permitted only when no data connection is established on the
port to be tested.
If, however, there is a data connection to the port to be tested, this is briefly interrupted.
Automatic re-establishment of the connection can fail and then needs to be done manually.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
205
Configuring with Web Based Management
5.4 The "System" menu
Description
The page contains the following boxes:
● Port
Select the required port from the drop-down list.
● Run Test
Activates error diagnostics. The result is shown in the table.
This table contains the following columns:
● Pair
Shows the wire pair in the cable.
Note
Wire pairs
Wire pairs 4-5 and 7-8 of 10/100 Mbps network cables are not used.
1000 Mbps or gigabit Ethernet uses all 4 wire pairs.
The wire pair assignment - pin assignment is as follows (DIN 50173):
Pair 1 = pin 4-5
Pair 2 = pin 1-2
Pair 3 = pin 3-6
Pair 4 = pin 7-8
● Status
Displays the status of the cable.
● Distance [m]
Displays the distance to the cable end, cable break, or short-circuit.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
206
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.4 The "System" menu
5.4.21.2
SFP diagnostics
On this page, you run independent error diagnostics for each individual SFP port. This test is
performed without needing to remove the cable, connect a cable tester or install a loopback
module at the other end.
Description
The page contains the following boxes:
● Port
Select the required port from the drop-down list.
● Refresh
Refreshes the display of the values of the set port. The result is shown in the table.
The values are shown in the following boxes:
● Name
Shows the name of the interface.
● Model
Shows the type of interface.
● Revision
Shows the hardware version of the SFP.
● Serial
Shows the serial number of the SFP
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
207
Configuring with Web Based Management
5.4 The "System" menu
● Nominal Bit Rate [Mbps]
Shows the nominal bit rate of the interface.
● Max. Link (50.0/125um) [m]
Shows the maximum distance in meters that is possible with this medium.
● Max. Link (62.5/125um) [m]
Shows the maximum distance in meters that is possible with this medium.
The following table shows the values of the SFP transceiver used in this port:
● Temperature [°C]
Shows the temperature of the interface.
● Voltage [V]
Shows the voltage applied to the interface [V].
● Current [mA]
Shows the current consumption of the interface [mA].
● RX Power [mW]
Shows the receive power of the interface [mW].
● Tx Power [uW]
Shows the transmit power of the interface [mW].
● Current column
Shows the current value.
● Low column
Shows the lowest value.
● High column
Shows the highest value.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
208
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5
The "Layer 2" menu
5.5.1
Configuration
Configuring layer 2
On this page, you create a basic configuration for the functions of layer 2. On the
configuration pages of these functions, you can make detailed settings. You can also check
the settings on the configuration pages.
Description of the displayed boxes
● Protocol Based VLAN
Enable or disable protocol-based VLAN. Other settings in "Layer 2 > VLAN".
● Subnet Based VLAN
Enable or disable subnet-based VLAN. Other settings in "Layer 2 > VLAN".
● Dynamic MAC Aging
Enable or disable the "Aging" mechanism. You can configure other settings in "Layer 2 >
Dynamic MAC Aging".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
209
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Redundancy Type
The following settings are available:
– "-" (disabled)
The redundancy function is disabled.
– Spanning Tree
If you select this option, you specify the required redundancy mode in the
"Redundancy Mode" drop-down list.
– Ring
If you select this option, you specify the required redundancy mode in the
"Redundancy Mode" drop-down list.
– Ring with RSTP
If you select this option, the compatibility mode for spanning tree is set permanently to
RSTP. In the "Redundancy Mode" drop-down list, you specify the redundancy mode of
the ring redundancy.
You can change the current setting in the "Ring Redundancy" and "Spanning Tree"
menus.
Note
Restriction relating to ports with the "Ring with RSTP" option
If you have enabled the "Ring with RSTP" option, the following ports must not be
included in the spanning tree:
• Ring ports
• Standby ports
• Standby coupling ports
SCALANCE XM-400/XR-500 Web Based Management (WBM)
210
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Redundancy Mode
If you select "Ring" or "Ring with RSTP"in the "Redundancy Type" drop-down list, the
following options are then available:
– Automatic Redundancy Detection
Select this setting to configure the redundant mode automatically.
In "Automatic Redundancy Detection" mode, the
IE Switch automatically detects whether or not there is a device with
the role of "HRP Manager" in the ring. If there is, the device adopts
the role "HRP" client.
If no HRP manager is found, all devices with the "Automatic Redundancy
Detection" or "MRP Auto Manager" setting negotiate among themselves to establish
which device adopts
the role of "MRP Manager". The device with the lowest MAC address will always
become
"MRP Manager". The other devices automatically set themselves
to "MRP Client" mode.
– MRP Auto-Manager
Automatic media redundancy manager
– MRP Client
Media redundancy client
– HRP Client
High Speed Redundancy Protocol client
– HRP manager
High Speed Redundancy Protocol manager
If you select "Spanning Tree" in the "Redundancy Type" drop-down list, the following
options are then available:
– STP
Enabled Spanning Tree Protocol. Typical reconfiguration times with spanning tree are
between 20 and 30 seconds. You can configure other settings in "Layer 2 > Spanning
Tree".
– RSTP
Enabled Rapid Spanning Tree Protocol (RSTP). If a spanning tree frame is detected
at a port, this port reverts from RSTP to spanning tree. You can configure other
settings in "Layer 2 > Spanning Tree".
Note
When using RSTP (Rapid Spanning Tree Protocol), loops involving duplication of
frames or frames being overtaken may occur briefly. If this is not acceptable in your
particular application, use the slower standard spanning tree mechanism.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
211
Configuring with Web Based Management
5.5 The "Layer 2" menu
– MSTP
Enables Multiple Spanning Tree Protocol (MSTP). You can configure other settings in
"Layer 2 > Spanning Tree".
If you select "Ring with RSTP" in the "Redundancy Type" drop-down list, the current
redundancy modes of the Spanning tree and ring redundancy are displayed.
● Standby
Enable or disable the standby redundancy function. You will find other settings in "Layer 2
> Ring Redundancy"
● Passive Listening
Enable or disable the passive listening function.
● RMON
If you select this check box, Remote Monitoring (RMON) allows diagnostics data to be
collected on the device, prepared and read out using SNMP by a network management
station that also supports RMON. This diagnostic data, for example port-related load
trends, allow problems in the network to be detected early and eliminated. Some of the
"Ethernet statistics counters" are part of the RMON function. If you disable RMON, the
"Ethernet statistics counter" in "Information > Ethernet statistics" is no longer updated.
● Dynamic Multicast
The following settings are possible:
– "-" (disabled)
– IGMP Snooping
Enables IGMP (Internet Group Management Protocol). You can configure other
settings in "Layer 2 > Multicast > IGMP".
– GMRP
Enables GMRP (GARP Multicast Registration Protocol). You can configure other
settings in "Layer 2 > Multicast > GMRP".
Note
GMRP and IGMP cannot operate at the same time.
● GVRP
Enable or disable "GVRP" (GARP VLAN Registration Protocol). You can configure other
settings in "Layer 2 > VLAN > GVRP".
● Mirroring
Enable or disable port mirroring. You can configure other settings in "Layer 2 > Mirroring".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
212
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Loop Detection
Enable or disable the loop detection function. This allows loops in the network to be
detected. You will find other settings in "Layer 2 > Loop Detection"
● PTP
The following setting is possible:
– off
The device does not process any PTP messages. PTP messages are, however,
forwarded according to the rules of the switch.
– transparent
The device adopts the function of a transparent clock and forwards PTP messages to
other nodes while at the same time making entries in the correction field of the PTP
message.
You will find other settings in "Layer 2 > PTP"
5.5.2
QoS
5.5.2.1
CoS queue mapping
CoS queue
Here, CoS priorities are assigned to certain queues (Traffic Queues).
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
213
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
The table has the following columns:
● CoS
Shows the CoS priority of the incoming packets.
● Queue
From the drop-down list, select the forwarding queue (send priority) that is assigned to
the CoS priority.
The higher the number of the queue, the higher the send priority.
With queues 1 - 6 frames with a lower priority are occasionally processed even if there
are frames with high priority in the queue.
With queues 7 - 8 only frames with a high priority are processed as long as there are
frames with high priority in the queue.
The service classes (COS) are assigned to the queues as follows:
● COS 0 → Queue 2
● COS 1 → Queue 1
● COS 2 → Queue 3
● COS 3 → Queue 4
● COS 4 → Queue 5
● COS 5 → Queue 6
● COS 6 → Queue 7
● COS 7 → Queue 8
Steps in configuration
1. For each value in the "CoS" column, select the forwarding queue from the "Queue" dropdown list.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
214
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.2.2
DSCP Mapping
DSCP Mapping
On this page, DSCP settings are assigned to various queues (Traffic Queues).
Description of the displayed values
The table has the following columns:
● DSCP
Shows the DSCP priority of the incoming packets.
● Queue
From the drop-down list, select the forwarding queue (send priority) that is assigned to
the DSCP value.
The higher the queue number, the higher the send priority.
With queues 1 - 6 frames with a lower priority are occasionally processed even if there
are frames with high priority in the queue.
With queues 7 - 8 only frames with a high priority are processed as long as there are
frames with high priority in the queue.
The DSCP codes are assigned to the queues as follows:
● DSCP codes 0 - 7 → Queue 2
● DSCP codes 8 - 15 → Queue 1
● DSCP codes 16 - 23 → Queue 3
● DSCP codes 24 - 31 → Queue 4
● DSCP codes 32 - 39 → Queue 5
● DSCP codes 40 - 47 → Queue 6
● DSCP codes 48 - 55 → Queue 7
● DSCP codes 56 - 63 → Queue 8
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
215
Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
1. For each value in the "DSCP" column, select the forwarding queue from the "Queue"
drop-down list.
2. Click the "Set Values" button.
5.5.2.3
QoS Trust
Specifying the subnet priority
On this page you can set the method according to which packets to be forwarded are
prioritized port by port.
Description of the displayed values
Table 1 has the following columns:
● Port
Shows that the setting is valid for all ports of table 2.
● Trust Mode
Select the setting from the drop-down list. You have the following setting options:
– No Trust
– Trust COS
– Trust DSCP
– Trust COS-DSCP
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
216
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● Port
Shows the configurable ports.
The port is made up of the module number and the port number, for example port 0.1 is
module 0, port 1.
● Trust Mode
Select the required mode from the drop-down list:
– No Trust
Incoming packets are forwarded with the priority of the receiving port. If there is a
DSCP value in the IP header, this is ignored. If a VLAN tag exists, it is replaced by the
priority value of the input port.
– Trust COS
If an incoming packet contains a VLAN tag, it is forwarded with this prioritization. If
there is a DSCP value in the IP header, this is ignored. If the packet does not contain
a VLAN tag it is forwarded with the prioritization of the receiving port.
– Trust DSCP
If an incoming packet contains a DSCP prioritization, it is forwarded with this
prioritization. If there is a VLAN tag, this is ignored. If the packet does not contain
DSCP prioritization it is forwarded with the prioritization of the receiving port.
– Trust COS-DSCP
With an incoming packet, there is a sequential check of which prioritization it contains.
If it contains a DSCP prioritization, it is handled as in the "Trust DSCP" mode.
If it contains no DSCP prioritization, it is checked for a VLAN tag. If it contains a VLAN
tag, it is forwarded with this prioritization. If the packet does not contain DSCP
prioritization or a VLAN tag it is forwarded with the prioritization of the receiving port.
Steps in configuration
1. Select the required value from the drop-down list.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
217
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.3
Rate Control
Limiting the transfer rate of incoming and outgoing data
On this page, you configure the load limitation (maximum number of data packets per
second) for the individual ports. You can specify the category of frame for which these limit
values will apply.
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Limit Ingress Unicast (DLF) / Limit Ingress Broadcast / Limit Ingress Multicast
Select the required setting in the drop-down list.
– enabled: Enables the function.
– disabled: Disables the function
– No Change: The setting in table 2 remains unchanged
● Total Ingress Rate [pkts/s]
Specify the maximum number of incoming packets processed by the device. If "No
Change is entered, the entry in the table remains unchanged.
● Egress Rate kb/s
Specify the data rate for all outgoing frames. If "No Change is entered, the entry in the
table remains unchanged
● Copy to table
If you click the button, the settings are adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
218
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● Port
Shows the slot and the port to which the other information relates. This field cannot be
configured. The port is made up of the module number and the port number, for example
port 0.1 is module 0, port 1.
● Limit Ingress Unicast (DLF)
Enable or disable the data rate for limiting incoming unicast frames with an unresolvable
address (Destination Lookup Failure).
● Limit Ingress Broadcast
Enable or disable the data rate for limiting incoming broadcast frames.
● Limit Ingress Multicast
Enable or disable the data rate for limiting incoming multicast frames.
● Total Ingress Rate [pkts/s]
Specify the maximum number of incoming packets processed by the device.
● Egress Rate kb/s
Specify the data rate for all outgoing frames.
Note
Rounding of the values, deviation from desired value
When you input the rate values, note that the WBM rounds to correct values.
If values are configured for Total Ingress Rate and Egress Rate, the actual values in
operation can deviate slightly from the set values.
Steps in configuration
1. Enter the relevant values in the columns "Total Ingress Rate"and "Egress rate" in the row
of the port being configured.
2. To use the limitation for the incoming frames, select the check box in the row. For
outgoing frames, the value in the "Egress Rate" column is used.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
219
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.4
VLAN
5.5.4.1
General
VLAN configuration page
On this page, you define the VLAN and specify the use of the ports.
Note
Changing the agent VLAN ID
If the configuration PC is connected directly to the device via Ethernet and you change the
agent VLAN ID, the device is no longer reachable via Ethernet following the change.
Important rules for VLANs
Make sure you keep to the following rules when configuring and operating your VLANs:
● Frames with the VLAN ID "0" are handled as untagged frames but retain their priority
value.
● As default, all ports on the device send frames without a VLAN tag to ensure that the end
node can receive these frames.
● With SCALANCE X devices, the VLAN ID "1" is the default on all ports.
● If an end node is connected to a port, outgoing frames should be sent without a tag (static
access port). If, however, there is a further switch at this port, the frame should have a
tag added (trunk port).
● With a trunk port, the VLAN assignment is dynamic. Static configurations can only be
created if, in addition to the trunk port property, the port is also entered statically as a
member in the VLANs involved. An example of a static configuration is the assignment of
the multicast groups in certain VLANs.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
220
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
The page contains the following boxes:
● VLAN ID
Enter the VLAN ID in the "VLAN ID" input box.
Range of values: 1 ... 4094
The table has the following columns:
● Select
Select the row you want to delete.
● VLAN ID
Shows the VLAN ID. The VLAN ID (a number between 1 and 4094) can only be assigned
once when creating a new data record and can then no longer be changed. To make a
change, the entire data record must be deleted and created again. Up to 257 VLANs can
be defined.
● Name
Enter a name for the VLAN. The name only provides information and has no effect on the
configuration. The length is a maximum of 32 characters.
● Status
Shows the status type of the entry in the internal port filter table. Here, static means that
the address was entered as a static address by the user. The entry GVRP means that the
configuration was registered by a GVRP frame. This is, however, only possible if GVRP
was enabled for the device.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
221
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Transparent
If you enable this check box, you switch a VLAN to the transparent mode. Ports that were
assigned to this VLAN as members or untagged members now become transparent
ports.
This means the following:
– The port VLAN ID of the transparent port is set to the ID of this VLAN.
– Untagged frames that are received at these ports are forwarded to all other
transparent ports once again without tag as long as they are not forwarded to a
standard VLAN by a protocol or subnet rule.
– Frames tagged with VLAN ID "0" and that are received at these ports are forwarded to
all other transparent ports once again tagged with VLAN ID "0" as long as they are not
forwarded to a standard VLAN by a protocol or subnet rule.
– Frames tagged with the VLAN ID of the transparent VLAN and that are received at
these ports are forwarded to all transparent ports once again tagged with the VLAN ID
of the transparent VLAN.
– Other frames are forwarded according to the normal VLAN rules and a transparent
port behaves like an untagged member in this VLAN.
– All ports that were not members or untagged members in the relevant VLAN are
automatically set to the "Forbidden" status.
– As long as a VLAN is configured as a transparent VLAN, the ports belonging to this
VLAN cannot be modified.
– You can only configure one a transparent VLAN.
● List of ports
Specify the use of the port. The following options are available:
– "-"
The port is not a member of the specified VLAN.
With a new definition, all ports have the identifier "-".
– M
The port is a member of the VLAN. Frames sent in this VLAN are forwarded with the
corresponding VLAN tag.
– R
The port is a member of the VLAN. A GVRP frame is used for the registration.
– U (uppercase)
The port is an untagged member of the VLAN. Frames sent in this VLAN are
forwarded without the VLAN tag. Frames without a VLAN tag are sent from this port.
– u (lowercase)
The port is an untagged member of the VLAN, but the VLAN is not configured as a
port VLAN. Frames sent in this VLAN are forwarded without the VLAN tag.
– F
The port is not a member of the specified VLAN and it is not possible for the VLAN to
be registered dynamically at this port using GVRP. If a port in a VLAN has this option,
it cannot become a member of this VLAN even if it is configured as a trunk port.
You can configure further settings in "Layer 2 > VLAN > Port-based VLAN".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
222
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
– T
This option is only displayed and cannot be selected in the WBM.
This port is a trunk port making it a member in all VLANs.
You configure this function in the CLI (Command Line Interface) using the "switchport
mode trunk" command.
Steps in configuration
1. Enter an ID in the "VLAN ID" input box.
2. Click the "Create" button. A new entry is generated in the table. As default, the boxes
have "-" entered.
3. Enter a name for the VLAN under Name.
4. Switch the VLAN to the transparent or standard compliant mode.
5. Specify the use of the port in the VLAN. If, for example you select M, the port is a
member of the VLAN. The frame sent in this VLAN is forwarded with the corresponding
VLAN tag.
6. Click the "Set Values" button.
5.5.4.2
GVRP
Configuration of GVRP functionality
Using GVRP frame, a different device can register at the port of the device for a specific VID.
A different device, can, for example be an end device or a switch. The device can also send
GVRP frames via this port.
On this page, you can enable each port for GVRP functionality.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
223
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
The page contains the following box:
● GVRP
Enable or disable the GVRP function.
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
Enables the sending of GVRP frames.
– disabled
Disables the sending of GVRP frames.
– No Change
No change in table 2.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
224
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Setting
Enable or disable the sending GVRP frames.
Steps in configuration
1. Click "GVRP" check box.
2. Click the check box after the port in the "Setting" column to enable or disable GVRP for
this port.
Repeat this for every port for which you want to enable or disable the function.
3. Click the "Set Values" button.
5.5.4.3
Port-based VLAN
Processing received frames
On this page, you specify the configuration of the port properties for receiving frames.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
225
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
Table 1 has the following columns:
● Port
Shows that the settings are valid for all ports.
● Priority / / Port-VID / Acceptable Frames / Ingress Filtering
Select the setting in the drop-down list. If "No Change" is selected, the entry in table 2
remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the available ports and link aggregations. The port is made up of the module
number and the port number, for example port 0.1 is module 0, port 1.
● Priority
From the drop-down list, select the priority given to untagged frames.
The CoS priority (Class of Service) used in the VLAN tag. If a frame is received without a
tag, it will be assigned this priority. This priority specifies how the frame is further
processed compared with other frames.
There are a total of eight priorities with values 0 to 7, where 7 represents the highest
priority (IEEE 802.1p Port Priority).
● Port VID
Select the VLAN ID from the drop-down list. Only VLAN IDs defined on the "VLAN >
General" page can be selected.
If a received frame does not have a VLAN tag, it has a tag with the VLAN ID specified
here added to it and is sent according to the rules at the port.
● Acceptable Frames
Specify which types of frames will be accepted. The following alternatives are possible:
– Tagged Frames Only
The device discards all untagged frames. Otherwise, the forwarding rules apply
according to the configuration.
– All
The device forwards all frames.
● Ingress Filtering
Specify whether the VID of received frames is evaluated
You have the following options:
– Enabled
The VLAN ID of received frames decides whether they are forwarded: To forward a
VLAN tagged frame, the receiving port must be a member in the same VLAN. Frames
from unknown VLANs are discarded at the receiving port.
– Disabled
All frames are forwarded.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
226
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
1. In the row of the port to be configured, click on the relevant cell in the table to configure it.
2. Enter the values to be set in the input boxes as follows.
3. Select the values to be set from the drop-down lists.
4. Click the "Set Values" button.
5.5.4.4
Protocol-based VLAN group
Introduction
On this page, you specify groups and assign a protocol to them.
Description of the displayed boxes
The page contains the following boxes:
● Protocol-based VLAN
Enable or disable the protocol-based VLAN assignment.
● Protocol Value
Enter the hexadecimal protocol value.
A few examples are shown below:
– PROFINET: 88:92
– IP: 08:00
– Novell: 81:37
– netbios: f0:f0
– appletalk: 80:9b
● Group ID
Enter the ID of the group.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
227
Configuring with Web Based Management
5.5 The "Layer 2" menu
The table has the following columns:
● Select
Select the row you want to delete.
● Protocol Value
Shows the protocol value.
● Group Identifier
Shows the group ID.
Steps in configuration
Adding an entry
1. Enter the protocol value in the "Protocol Value" input box.
2. Enter the ID for the group in the Group Identifier input box.
3. Click the "Create" button. A new entry is generated in the table.
4. Click the "Set Values" button.
Deleting an entry
1. On the "Protocol-based VLAN port" tab, check that the protocol group is not used at any
port.
2. Select the check box in the row to be deleted.
3. Click the "Delete" button.
4. Click the "Set Values" button.
5.5.4.5
Protocol-based VLAN port
Introduction
On this page, you specify which protocol and which VLAN is assigned to the individual port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
228
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
The page contains the following boxes:
● Port
Select the port in the drop-down list. All available ports and the link aggregations can be
selected.
● Group Identifier
Select the group ID in the drop-down list. You specify the ID the WBM page "Protocol
Based VLAN Group".
The table has the following columns:
● Select
Select the row you want to delete.
● Port
All available ports and the link aggregations are shown.
● Group Identifier
Shows the group ID assigned to the port.
● VLAN ID
From the drop-down list, select the VLAN ID you want to assign to the port.
Steps in configuration
1. Select the port from the "Port" drop-down list.
2. Select the group ID from the "Group Identifier" drop-down list.
3. Click the "Create" button. A new entry is generated in the table.
4. Specify the VLAN ID in " VLAN ID".
5. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
229
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.4.6
IPv4 subnet-based VLAN
Introduction
On this page, you specify which VLAN ID is assigned to the subnet.
Description of the displayed boxes
The page contains the following boxes:
● Subnet-based VLAN
Enable or disable the IPv4 subnet-based VLAN assignment.
● Port
Select the port in the drop-down list. All available ports and the link aggregations can be
selected.
● Subnet Address
Enter the IPv4 address of the subnet.
Example: 192.168.10.0 for the network 192.168.10.x with nodes 192.168.10.1 to
192.168.10.254.
● Subnet Mask
Enter the subnet mask.
The table has the following columns:
● Select
Select the row you want to delete.
● Port
All available ports and the link aggregations are shown.
● Subnet Address
Shows the IPv4 address of the port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
230
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Subnet Mask
Shows the subnet assigned to the port.
● VLAN ID
Select the VLAN ID you want to assign to the port or the subnet.
Steps in configuration
1. Select a port from the "Port" drop-down list.
2. In "Subnet", enter the subnet mask.
3. Click the "Create" button. A new entry is generated in the table.
4. Select the VLAN ID from the "VLAN ID" drop down list.
5. Click the "Set Values" button.
5.5.5
Mirroring
Note
It cannot be guaranteed when mirroring the data traffic that all packets are mirrored.
Mirroring
The device provides the option of simultaneously channeling incoming or outgoing data
streams via other interfaces for analysis or monitoring. This has no effect on the monitored
data streams. This procedure is known as mirroring. In this menu section, you enable or
disable mirroring and set the parameters.
Mirroring ports
Mirroring a port means that the data traffic at a port (mirrored port) of the IE switch is copied
to another port (monitor port). You can mirror one or more ports to a monitor port.
If a protocol analyzer is connected to the monitor port, the data traffic at the mirrored port
can be recorded without interrupting the connection. This means that the data traffic can be
investigated without being affected. This is possible only if a free port is available on the
device as the monitor port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
231
Configuring with Web Based Management
5.5 The "Layer 2" menu
Function Extender BUS ANALYZER Agent XM-400
You can use the Function Extender BUS ANALYZER Agent XM-400 with the basic devices
SCALANCE XM-400 as of firmware version 5.1.
The function extender BUS ANALYZER Agent XM-400 is a modular network component with
4 internal monitor ports for port mirroring. Ports of the basic device can be mirrored on the
internal ports of the function extender BUS ANALYZER Agent XM-400 and their data traffic
recorded. You do not need to reserve any ports of the basic device or a port extender for
this.
● The mirrored data traffic is available on the management port (M1) of the BUS
ANALYZER Agent XM-400.
● To record the mirrored data traffic, the software BUS ANALYZER SCOPE is used.
5.5.5.1
General
Mirroring in general
On this page, you can enable or disable the "Mirroring" function and make the basic settings.
Note
Mirroring a port does not work beyond switch core boundaries. Refer to the operating
instructions of the device.
Note
You need to disable port mirroring if you want to connect a normal end device to the monitor
port. This does not apply to the function extender BUS ANALYZER Agent XM-400.
Note the data rate
If the maximum data rate of the mirrored port is higher than that of the monitor port, data
may be lost and the monitor port no longer reflects the data traffic at the mirrored port.
Several ports can be mirrored to one monitor port at the same time.
Several source ports from the same VLAN
If in a VLAN you select more than one source port for the port-based egress mirroring,
unknown unicast and multicast frames as well as broadcast frames are forwarded only once
to the destination port. With several sessions, the corresponding frames are only visible in
one session, they are only mirrored to one destination port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
232
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
RSPAN
With RSPAN (Remote Switched Port Analyzer) you can forward the data traffic of a mirroring
session to the monitor port via a VLAN. On the RSPAN VLAN, the mirrored data traffic is not
disturbed by other data.
Settings
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
233
Configuring with Web Based Management
5.5 The "Layer 2" menu
The page contains the following boxes:
● Mirroring
Click this check box to enable or disable mirroring.
● Monitor Barrier
Click this check box to enable or disable Monitor Barrier
Note
Effects of monitor barrier
If you enable this option, management of the switch via the monitor port is no longer
reachable. The following port-specific functions are changed:
• DCP forwarding is turned off
• LLDP is turned off
• Unicast, multicast and broadcast blocking is turned on
The previous statuses of these functions are no longer restored after disabling monitor
barrier again. They are reset to the default values and may need to be reconfigured.
You can reconfigure these functions manually even if monitor barrier is turned on. The
data traffic on the monitor port is also allowed again. If you do not require this, make sure
that only the data traffic you want to monitor is forwarded to the interface.
If mirroring is disabled, the listed port-specific functions are reset to the default values.
This reset takes place regardless of whether the functions were configured manually or
automatically by enabling "Monitor Barrier".
Note
Function Extender BUS ANALYZER Agent XM-400
If the destination port is a port of the function extender BUS ANALYZER Agent XM-400
the monitor barrier option is always activated. It is activated regardless of whether the
check box was disabled or enabled.
● RSPAN VLAN ID
● Select a VLAN.
The table for the basic settings contains the following boxes:
● Select
Select the row you want to delete.
● Session ID
The Session ID is assigned automatically when a new entry is created.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
234
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Session Type
Select the required entry from the drop-down list:
– None
– Port-based
Port-based mirroring
– VLAN
VLAN-based mirroring
– MAC ACL
Mirroring of the MAC Access Control List
– IP ACL
Mirroring of the IP Access Control List
Note
If you have created a session of the type "VLAN" "MAC ACL" or "IP ACL", you cannot
create any further sessions. You can create up to 7 sessions of the type "Port-based".
Note
If you change the "Session Type" of an existing session, all previous configurations of this
session are lost.
● Status
Shows whether or not mirroring is enabled.
● Dest. Port
From the drop-down list, select the destination port to which data will be mirrored in this
session.
Note
Function Extender BUS ANALYZER Agent XM-400
If you connect a function extender BUS ANALYZER Agent XM-400 with a SCALANCE
XM-400 basic device as of firmware version 5.1, you can select up to four ports of the
function extender BUS ANALYZER Agent XM-400 as destination ports. Function
extender BUS ANALYZER Agent XM-400 supports port-based, VLAN-based, MAC ACLbased and IP ACL-based mirroring.
● RSPAN
Enable or disable RSPAN for a session.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
235
Configuring with Web Based Management
5.5 The "Layer 2" menu
Procedure
Creating a mirroring session
1. Activate mirroring.
2. Click the "Create" button to create a further entry in the table.
The session ID is assigned automatically. Depending on the session type selected, you
can create one or more mirroring sessions.
3. Select a "Session Type".
4. Click the "Set Values" button.
5. Select a destination port.
6. Click the "Set Values" button to save and activate the selected settings.
7. Change to the following tabs to make further detailed settings for the relevant session ID.
Deleting a mirroring session
1. Click the check box in the first column to select the row.
2. Click the "Delete" button to delete the selected rows.
Mirroring with RSPAN
1. Create a VLAN for the RSPAN data traffic on all devices involved.
Note
You can only create one RSPAN VLAN.
2. Create a mirroring session.
3. Select the "RSPAN VLAN ID.
4. Enable the check box in the "RSPAN" column.
5. Click the "Set Values" button to save the selected settings.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
236
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.5.2
Port
Mirroring ports
You can only configure the settings on this page if you have already generated a session ID
with the session type "Port-based" on the "General" tab.
Description of the displayed boxes
The page contains the following drop down list:
● Session ID
Select the session you want to monitor. Up to 7 parallel sessions are possible and their
ports must not overlap.
The table has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Ingress Mirroring
Enable or disable listening in on incoming packets at the required port.
● Egress Mirroring
Enable or disable listening in on outgoing packets at the required port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
237
Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
1. In the "Session ID" drop-down list, select the session you created earlier on the "General"
tab.
2. In the table, click the check box of the row after the port to be mirrored.
Select whether you want to monitor incoming or outgoing packets.
To monitor the entire data traffic of the port, select both check boxes.
3. Click the "Set Values" button.
5.5.5.3
VLAN
VLAN sources of the port mirroring
You can only configure the settings on this page if you have already generated a session ID
with the session type "VLAN" on the "General" tab.
On this page, you specify the VLAN whose incoming data traffic will be mirrored to the
monitor port.
Description of the displayed boxes
The page contains the following boxes:
● Session ID
Select the session you want to monitor. Only one session is possible.
● VLAN ID
Enter the VLAN ID in the "VLAN ID" input box.
Range of values: 1 ... 4094
The table "Ingress Mirroring " has the following columns:
● Select
Select the row you want to delete.
● VLAN ID
Shows the VLAN ID for which the incoming frames are mirrored. The VLAN ID (a number
between 1 and 4094) can only be assigned once when creating a new data record and
can then no longer be changed. To make a change, the entire data record must be
deleted and created again. Up to 257 VLANs can be defined.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
238
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.5.4
MAC Flow
ACL filter for port mirroring
You can only configure the settings on this page if you have already generated a session ID
with the session type " "MAC ACL" on the "General" tab.
The ACL filter decides which data is available at the monitor port.
Description of the displayed boxes
● Session ID
Select the session you want to monitor. Only one session is possible.
● ACL Filter Number
Shows the number of the ACL filter.
● Ingress Mirroring
Shows whether incoming packets are mirrored.
Note
Rules
The selected rule only becomes active when you specify with which ACL rules the
incoming packets will be filtered for at least one interface. You configure the settings in
"Security > MAC ACL > Ingress Rules".
● Source MAC
Shows the MAC address of the sender.
● Dest. MAC
Shows the MAC address of the recipient.
● Ingress Interfaces
Shows all interfaces to which this rule applies. The ACL filter decides which incoming
data streams are mirrored on the monitor port (destination port).
● Egress Interfaces
Shows all interfaces to which this rule applies.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
239
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.5.5
IP Flow
ACL filter for port mirroring
You can only configure the settings on this page if you have already generated a session ID
with the session type " "IP ACL" on the "General" tab.
The ACL filter decides which data is available at the monitor port.
Description of the displayed boxes
● Session ID
Select the session you want to monitor. Only one session is possible.
● ACL Filter Number
Shows the number of the ACL filter.
● Ingress Mirroring
Shows whether incoming packets are mirrored.
Note
Rules
The selected rule only becomes active when you specify with which ACL rules the
incoming packets will be filtered for at least one interface. You configure the settings in
"Security > IP ACL > Ingress Rules".
● Source IP
Shows the IPv4 address of the destination device.
● Source Subnet Mask
Shows the subnet mask of the sender.
● Dest. IP
Shows the IPv4 address of the recipient.
● Dest. Subnet Mask
Shows the subnet mask of the recipient.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
240
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Ingress Interfaces
Shows all interfaces to which this rule applies. The ACL filter decides which incoming
data streams are mirrored on the monitor port (destination port).
● Egress Interfaces
Shows all interfaces to which this rule applies. The ACL filter decides which outgoing data
streams are mirrored on the monitor port (destination port).
5.5.6
Dynamic MAC Aging
Protocol settings and switch functionality
The device automatically learns the source addresses of the connected nodes. This
information is used to forward data frames to the nodes specifically involved. This reduces
the network load for the other nodes.
If a device does not receive a frame whose source address matches a learnt address within
a certain time, it deletes the learnt address. This mechanism is known as "Aging". Aging
prevents frames being forwarded incorrectly, for example when an end device (for example a
programming device) is connected to a different switch port.
If the check box is not enabled, a device does not delete learnt addresses automatically.
Description of the displayed boxes
The page contains the following boxes:
● Dynamic MAC Aging
Enable or disable the function for automatic aging of learned MAC addresses:
● Aging Time [s]
Enter the time in seconds. After this time, a learned address is deleted if the device does
not receive any further frames from this sender address. The range of values is from 10
seconds to 630 seconds
Steps in configuration
1. Select the "Dynamic MAC Aging" check box.
2. Enter the time in seconds in the "Aging Time [s]" input box.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
241
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.7
Ring redundancy
5.5.7.1
Ring
Rules for ring redundancy
Factory settings
● The factory setting defines MSTP as the redundancy method.
● With SCALANCE XM-400, the factory setting defines ports P1.1 and P1.2 as ring ports.
● With SCALANCE XM-500, the factory setting defines ports P0.1 and P0.2 as ring ports.
Ring ports
The predefined ring ports of SCALANCE XR-500 are 10 Gbps ports.
If a 1000 Mbps SFP transceiver is plugged into one of the 10 Gbps ring ports, you cannot
enable ring redundancy.
Remove the 1000 Mbps SFP transceiver.
Enabling redundancy
You can enable ring redundancy as follows:
● using the WBM
● using the CLI
● using the SELECT/SET button
● using a PNIO configuration download
Configuration of ring redundancy
SCALANCE XM-400/XR-500 Web Based Management (WBM)
242
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Ring Redundancy
If you enable the "Ring Redundancy" check box, you turn ring redundancy on. The ring
ports set on this page are used.
● Ring redundancy mode
Here, you set the mode of the ring redundancy.
The following modes are available:
– Automatic Redundancy Detection
Select this setting to create an automatic configuration of the redundancy mode.
In the "Automatic Redundancy Detection" mode, the device automatically detects
whether or not there is a device with the "HRP Manager" role in the ring. If there is, the
device adopts the role "HRP" client.
If no HRP manager is found, all devices with the "Automatic Redundancy Detection"
or "MRP Auto Manager" setting negotiate among themselves to establish which
device adopts the role of "MRP Manager". The device with the lowest MAC address
will always become "MRP Manager". The other devices automatically set themselves
to "MRP Client" mode.
– MRP Auto-Manager
Automatic media redundancy manager
– MRP Client
Media redundancy client
– HRP Client
High Speed Redundancy Protocol client
– HRP Manager
High Speed Redundancy Protocol manager
● Ring ports
Here, you set the ports to be used as ring ports in ring redundancy.
The ring port you select in the left-hand drop-down menu is the "Isolated Port" in HRP.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
243
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Observer
Enable or disable the observer. The "Observer" function is only available in HRP rings.
The ring port selected in the left-hand drop-down menu is connected to the "isolated port"
of an HRP manager.
The observer monitors malfunctions of the redundancy manager or incorrect
configurations of an HRP ring.
If the observer is enabled, it can interrupt the connected ring if errors are detected. To do
this, the observer switches a ring port to the "blocking" status. When the error is resolved,
the observer enables the port again.
● Restart Observer
If numerous errors occur in quick succession, the observer no longer enables its port
automatically. The ring port remains permanently in the "blocking" status. This is signaled
by the error LED and a message text.
After the errors have been eliminated, you can enable the port again using the "Restart
Observer" button.
Restoring factory settings
If you have restored the factory defaults, ring redundancy is disabled and the default ports
are used as the ring ports. This can lead to circulating frames and failure of the data traffic if
other settings were used in a previous configuration.
Changing over the status of the ring ports with the redundancy manager
If you configure a redundancy manager, set the status of the ring ports. The first ring port
changes to the "blocking" status and the second ring port to the "forwarding" status. As long
as ring redundancy is enabled, you cannot change the status of these ring ports.
Note
Make sure that you first open the ring so that there are no circulating frames.
Changing ring ports
You can change the ring ports without needing to open the ring.
To change the ring ports, follow the steps below:
1. Change to the page "Layer 2 > Spanning Tree > CIST Port".
2. Disable the ports in the spanning tree you want to configure as ring ports.
3. Change to the page "Layer 2 > Ring Redundancy > Ring".
4. Select the new ring ports.
5. Change the cable connections.
6. Change to the page "Layer 2 > Spanning Tree > CIST Port".
7. Enable the ports in the spanning tree that are no longer ring ports.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
244
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.7.2
Standby
Redundant linking of rings
Standby redundancy allows the redundant linking of HRP rings.
To establish a standby connection, configure two neighboring devices within a ring as
standby master or standby slave. The standby master and the standby slave must be
connected via parallel cables to two devices in another ring.
In problem-free operation, messages are exchanged between the two rings via the master. If
the master's line is disturbed, the slave takes over the forwarding of messages between the
two rings.
Enable standby redundancy for both standby partners and select the ports via which the
device is connected to the rings you want to link to.
For the "Standby Connection Name", a name unique within the ring must be assigned for
both partners. This identifies the two devices as standby partners that belong together.
Note
To be able to use the function, HRP must be activated.
The standby manager always requires an activated HRP client.
Note
Standby master coupling with an optical 100 Mbps connection
While the coupling partner of a standby master with an optical 100 Mbps connection starts
up again, physically disconnect the connection between the standby master and its coupling
partner.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
245
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
● Standby
Click the check box to enable or disable the function.
● Standby Port
Select the port to be standby port. The link to the other ring is via the standby port.
Note
Standby ports in the spanning tree
Before you enable the port as the standby port, you need to disable the port in the
spanning tree.
1. Change to the page "Layer 2 > Spanning Tree > CIST Port".
2. Disable the ports in the spanning tree you want to configure as standby ports.
The standby port is involved in the redirection of data traffic. In there are no problems,
only the standby port of the master is enabled and handles the data traffic into the
connected HRP ring or HRP bus.
If the master or the Ethernet connection (link) of one of the standby ports of the master
fails, the standby port of the master will be disabled and the standby port of the slave
enabled. As a result, a functioning Ethernet connection to the connected network
segment (HRP ring or HRP linear bus) is restored.
● Standby Connection Name
This name defines the master/slave device pair. Both devices must be located in the
same ring.
Here, enter the name for the standby connection. This must be identical to the name
entered on the standby partner. You can select any name to suit your purposes, however,
you can only use the name for one pair of devices in the entire network.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
246
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Force device to Standby Master
If you select this check box, the device is configured as a standby master regardless of its
MAC address.
– If this check box is not selected for either of the devices for which the standby master
is enabled, then assuming that no error has occurred, the device with the higher MAC
address adopts the role of standby master.
– If the option is selected for both devices or if the "Force device to Standby Master"
property is supported by only one device, the standby master is also selected based
on the MAC address.
This type of assignment is important in particular when a device is replaced. Depending
on the MAC addresses, the previous device with the slave function can take over the role
of the standby master.
Note
If two devices are linked by the standby function, the "Standby" function must be enabled
on both devices.
● Wait for Standby Partner
– Enabled
A standby connection is enabled only after the standby master and the standby slave
as well as their standby partners have established a connection. This ensures that the
redundant connection is really available before communication via a standby
connection is enabled.
– Disabled
A standby connection is enabled even if the standby master has not yet established a
connection to the standby slave.
This can lead to circulating frames and failure of the data traffic if another standby
connection has already been enabled. Multiple standby connections can, for example,
result due to configuration errors if different standby connection names were assigned
to the standby master and standby slave.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
247
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.8
Spanning tree
5.5.8.1
General
General settings of MSTP
This is the basic page for spanning tree. Select the compatibility mode from the drop-down
list. As default, Multiple Spanning Tree is enabled.
On the configuration pages of these functions, you can make further settings.
Depending on the compatibility mode, you can configure the corresponding function on the
relevant configuration page.
Description of the displayed boxes
The page contains the following boxes:
● Spanning Tree
Enable or disable Spanning Tree.
● Protocol Compatibility
Select the compatibility mode of MSTP. For example if you select RSTP, MSTP behaves
like RSTP.
The following settings are available:
– STP
– RSTP
– MSTP
Steps in configuration
1. Select the "MSTP" check box.
2. From the "Protocol Compatibility" drop-down list, select the type of compatibility.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
248
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.8.2
CIST General
MSTP-CIST configuration
The page consists of the following parts.
● The left-hand side of the page shows the configuration of the device.
● The central part shows the configuration of the root bridge that can be derived from the
spanning tree frames received by an device.
● The right-hand side shows the configuration of the regional root bridge that can be
derived from the MSTP frames received by an device. The displayed data is only visible if
you have enabled "Spanning Tree"on the "General" page and if "MSTP" is set for
"Protocol Compatibility". This also applies to the "Bridge Max Hop Count" parameter. If
the device is a root bridge, the information on the left and right matches.
Description of the displayed boxes
The page contains the following boxes:
● Bridge Priority / Root Priority
The Bridge Priority decides which device becomes the Root Bridge. The Bridge with the
highest priority becomes the Root Bridge. The lower the value, the higher the priority. If
several devices in a network have the same priority, the device whose MAC address has
the lowest numeric value will become the root bridge. Both parameters, bridge priority
and MAC address together form the Bridge identifier. Since the root bridge manages all
path changes, it should be located as centrally as possible due to the delay of the frames.
The value for the bridge priority is a whole multiple of 4096 with a range of values from 0
through 61440.
● Bridge Address / Root Address
The bridge address shows the MAC address of the device and the root address shows
the MAC address of the root bridge.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
249
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Root port
Shows the port via which the switch communicates with the root bridge.
● Root Cost
The path costs from this device to the root bridge.
● Topology Changes / Last Topology Change
The entry for the device shows the number of reconfiguration actions due to the spanning
tree mechanism since the last startup. For the root bridge, the time since the last
reconfiguration is displayed as follows:
– Seconds: sec unit after the number
– Minutes: min unit after the number
– Hour: hr unit after the number
● Bridge hello time [s] / Root hello time [s]
Each bridge sends configuration frames (BPDUs) regularly. The interval between two
such frames is the Hello time. The default for this parameter is 2 seconds.
● Bridge forward delay[s] / Root Forward Delay [s]
New configuration data is not used immediately by a bridge but only after the period
specified in the parameter. This ensures that operation is only started with the new
topology after all the bridges have the required information. The default for this parameter
is 15 seconds.
● Bridge Max Age / Root Max Age
When the max age timer elapses the received BPDU is discarded to be accepted as valid
by the switch. The default value is 20s.
● Regional root priority
For a description, see Bridge Priority / Root Priority
● Regional root address
The MAC address of the device.
● Regional Root Costs
The path costs from this device to the root bridge.
● Bridge Max Hop Count
This parameter specifies how many MSTP nodes a BPDU may pass through. If an MSTP
BPDU is received and has a hop count that exceeds the value configured here, it is
discarded. The default for this parameter is 20.
● Reset Counters
Click this button to reset the counters on this page.
● Region Name
Enter the name of the MSTP region to which this device belongs. As default, the MAC
address of the device is entered here. This value must be the same on all devices that
belong to the same MSTP region.
● Region Version
Enter the version number of the MSTP region in which the device is located. This value
must be the same on all devices that belong to the same MSTP region
SCALANCE XM-400/XR-500 Web Based Management (WBM)
250
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
1. Enter the data required for the configuration in the input boxes.
2. Click the "Set Values" button.
5.5.8.3
CIST Port
MSTP-CIST port configuration
When the page is called, the table displays the current status of the configuration of the port
parameters.
To configure them, click the relevant cells in the port table.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
251
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Spanning Tree Status
Select the setting from the drop-down list. You have the following setting options:
– enabled
Port is integrated in the spanning tree.
– disabled
Port is not integrated in the spanning tree.
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Spanning Tree Status
Specify whether or not the port is integrated in the spanning tree.
Note
If you disable the "Spanning Tree Status" option for a port, this may cause the formation
of loops. The topology must be kept in mind.
● Priority
Enter the priority of the port. The priority is only evaluated when the path costs are the
same.
The value must be divisible by 16. If the value that cannot be divided by 16, the value is
automatically adapted.
Range of values: 0 - 240.
The default is 128.
● Cost Calc.
Enter the path cost calculation. If you enter the value "0", the automatically calculated
value is displayed in the "Path Cost" box.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
252
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Path Cost
This parameter is used to calculate the path that will be selected. The path with the
lowest value is selected as the path. If several ports of a device have the same value for
the path costs, the port with the lowest port number is selected.
If the value in the "Cost Calc" field is "0", the automatically calculated value is displayed.
Otherwise, the value of the "Cost Calc" field is displayed.
The calculation of the path costs is largely based on the transmission speed. The higher
the achievable transmission speed is, the lower the value of the path costs.
Typical values for path costs with rapid spanning tree:
– 10,000 Mbps = 2,000
– 1000 Mbps = 20,000
– 100 Mbps = 200,000
– 10 Mbps = 2,000,000
The values can, however, also be set individually.
● Status
Displays the current status of the port. The values are only displayed and cannot be
configured. The "Status" parameter depends on the configured protocol. The following is
possible for status:
– Disabled
The port only receives and is not involved in STP, MSTP and RSTP.
– Discarding
In the "Discarding" mode, BPDU frames are received. Other incoming or outgoing
frames are discarded.
– Listening
In this status, BPDUs are both received and sent. The port is involved in the spanning
tree algorithm.
– Learning
Stage prior to the forwarding status, the port is actively learning the topology (in other
words, the node addresses).
– Forwarding
Following the reconfiguration time, the port is active in the network; it receives and
forwards data frames.
● Fwd. Trans
Specifies the number of changes from the "Discarding" status to the "Forwarding" status.
● Edge Type
Specify the type of edge port. You have the following options:
– "-"
Edge port is disabled. The port is treated as a "no EdgePort".
– Admin
Select this option when there is always an end device on this port. Otherwise a
reconfiguration of the network will be triggered each time a connection is changed.
– Auto
Select this option if you want a connected end device to be detected automatically at
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
253
Configuring with Web Based Management
5.5 The "Layer 2" menu
this port. When the connection is established the first time, the port is treated as a "no
Edge Port".
– Admin/Auto
Select these options if you operate a combination of both on this port. When the
connection is established the first time, the port is treated as an Edge Port.
● Edge
Shows the status of the port.
– Enabled
An end device is connected to this port.
– Disabled
There is a Spanning Tree or Rapid Spanning Tree device at this port.
With an end device, a switch can change over the port faster without taking into account
spanning tree frames. If a spanning tree frame is received despite this setting, the port
automatically changes to the "Disabled" setting for switches.
● P.t.P. Type
Select the required option from the drop-down list. The selection depends on the port that
is set.
– "-"
Point to point is calculated automatically. If the port is set to half duplex, a point-topoint link is not assumed.
– P.t.P.
Even with half duplex, a point-to-point link is assumed.
– Shared Media
Even with a full duplex connection, a point-to-point link is not assumed.
Note
Point-to-point connection means a direct connection between two devices. A shared
media connection is, for example, a connection to a hub.
● Hello Time
Enter the interval after which the bridge sends configuration BPDUs. As default, 2
seconds is set.
Range of values: 1-2 seconds
Note
The port-specific setting of the Hello time is only possible in MSTP compatible mode.
Steps in configuration
1. In the input cells of the table row, enter the values of the port you are configuring.
2. From the drop-down lists of the cells of the table row, select the values of the port you are
configuring.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
254
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.8.4
MST General
Multiple Spanning Tree configuration
With MSTP, in addition to RSTP, several VLANs can be managed in a LAN with separate
RSTP trees.
Description
The page contains the following box:
● MSTP Instance ID
Enter the number of the MSTP instance.
Permitted values: 1 - 64
You can define up to 16 MSTP instances.
The table has the following columns:
● Select
Select the row you want to delete.
● MSTP instance ID
Shows the number of the MSTP instance.
● Root Address
Shows the MAC address of the root bridge
● Root Priority
Shows the priority of the root bridge.
● Bridge Priority
Enter the bridge priority in this box. The value for the bridge priority is a whole multiple of
4096 with a range of values from 0 to 61440.
● VLAN ID
Enter the VLAN ID. Here, you can also specify ranges with Start ID, "-", End ID. Several
ranges or IDs are separated by ",".
Permitted values: 1- 4094
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
255
Configuring with Web Based Management
5.5 The "Layer 2" menu
Procedure
Creating a new entry
1. Enter the number of the MSTP instance in the "MSTP Instance ID" box.
2. Click the "Create" button.
3. Enter the identifier of the virtual LAN in the "VLAN ID" input box.
4. Enter the priority of the bridge in the "Bridge Priority" box.
5. Click the "Set Values" button.
Deleting entries
1. Use the check box at the beginning of the relevant row to select the entries to be deleted.
2. Click the "Delete" button to delete the selected entries from memory. The entries are
deleted from the memory of the device and the display on this page is updated.
5.5.8.5
MST Port
Configuration of the Multiple Spanning Tree port parameters
On this page, you set the parameters for the ports of the configured multiple spanning tree
instances.
Description of the displayed boxes
The page contains the following box:
● MSTP Instance ID
In the drop-down list, select the ID of the MSTP instance.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
256
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● MSTP Status
Select the setting from the drop-down list. You have the following setting options:
– enabled
– disabled
– No Change: Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows all available ports and link aggregations.
● MSTP Instance ID
ID of the MSTP instance.
● MSTP Status
Click the check box to enable or disable this option.
● Priority
Enter the priority of the port. The priority is only evaluated when the path costs are the
same.
The value must be divisible by 16. If the value that cannot be divided by 16, the value is
automatically adapted.
Range of values: 0 - 240.
The default is 128.
● Cost Calc.
Enter the path cost calculation in the input box. If you enter the value "0" here, the
automatically calculated value is displayed in the next box "Path Cost".
● Path cost
The path costs from this port to the root bridge. The path with the lowest value is selected
as the path. If several ports of a device have the same value, the port with the lowest port
number is selected.
If the value in the "Cost Calc" field is "0", the automatically calculated value is displayed.
Otherwise, the value of the "Cost Calc" field is displayed.
The calculation of the path costs is largely based on the transmission speed. The higher
the achievable transmission rate, the lower the value for the path costs will be.
Typical values for rapid spanning tree are as follows:
– 1000 Mbps = 20,000
– 100 Mbps = 200,000
– 10 Mbps = 2,000,000
The values can, however, also be set individually.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
257
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Status
Displays the current status of the port. The values are only displayed and cannot be
configured. The following is possible for status:
– Discarding
The port exchanges MSTP information but is not involved in the data traffic.
– Blocked
In the blocking mode, BPDU frames are received.
– Forwarding
The port receives and sends data frames.
● Fwd. Trans.
Specifies the number of status changes Discarding - Forwarding or Forwarding Discarding for a port.
Steps in configuration
1. In the input cells of the table row, enter the values of the port you are configuring.
2. From the drop-down lists of the cells of the table row, select the values of the port you are
configuring.
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
258
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.8.6
Enhanced Passive Listening Compatibility
Enabling the function
On this page, you can enable passive listening compatibility.
Description of the displayed boxes
The page contains the following boxes:
● Enhanced Passive Listening Compatibility
Enable or disable this function for the entire device.
● Setting
– enabled
Enable the function for all ports of the device
– disabled
Disable the function for all ports of the device
– No Change
No Change
● Copy to Table
Writes the setting made in "Setting" to the following table
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
259
Configuring with Web Based Management
5.5 The "Layer 2" menu
Port-specific table:
If the function is enabled for the entire device, enable or disable this function on individual
ports.
● Port
Displays the port of the device.
● Setting
Enable or disable the function for this port
Steps in configuration
Enable the function for the entire device
1. Enable or disable "Enhanced Passive Listening Compatibility"
2. Click the "Set Values" button.
For all ports of the device:
1. From the drop-down list, select whether the function should be enabled or disabled or
adopted unchanged.
2. Click the "Copy to Table" button.
3. Click the "Set Values" button.
For individual ports of the device:
1. Click the check box after the required port in the port table to enable or disable the
function.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
260
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.9
Loop Detection
With the "Loop detection" function, you specify the ports for which loop detection will be
activated. The ports involved send special test frames - the loop detection frames. If these
frames are sent back to the device, there is a loop.
A "Local loop" involving this device means that the frames are received again at a different
port of the same device. If the sent frames are received again at the same port, there is a
"remote loop" involving other network components.
Note
A loop is an error in the network structure that needs to be eliminated. The loop detection
can help to find the errors more quickly but does not eliminate them. The loop detection is
not suitable for increasing network availability by deliberately including loops.
Note
Note that loop detection is only possible at ports that were not configured as ring ports or
standby ports.
Description
● Loop Detection
Enable or disable the loop detection.
● VLAN Loop Detection
Enable or disable the VLAN loop detection.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
261
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 1 contains the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2
● Threshold value / Remote reaction / Local reaction
Make the required settings.
● Copy to table
If you click the button, the setting is adopted for all ports of table 2
Table 2 contains the following columns:
● Port
Shows the available ports.
● Setting
Specify how the port handles loop detection frames. Select one of the following options
from the drop-down list:
Note
Test frames create additional network load. We recommend that you only configure
individual switches, for example at branch points of the ring, as "Sender" and the others
as "Forwarder".
– Sender
Loop detection frames are sent out and forwarded.
– Forwarder
Loop detection frames from other devices are forwarded.
– blocked
The forwarding of loop detection frames is blocked.
● Threshold
By entering a number, specify the number of received loop detection frames as of which
a loop is assumed.
● Remote reaction
Specify how the port will react if a remote loop occurs. Select one of the two options from
the drop-down list:
– no action: A loop has no effect on the port.
– disable: The port is blocked.
● Local reaction
Specify how the port will react if a local loop occurs. Select one of the two options from
the drop-down list:
– no action: A loop has no effect on the port.
– disable: The port is blocked
● Status
This box shows whether loop detection is enabled or disabled for this port.
● Source Port
Shows the receiving port of the loop detection frame that triggered the last reaction.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
262
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Source VLAN
This box shows the VLAN ID of the loop detection frame that triggered the last reaction.
This requires that the "VLAN Loop Detection" check box is selected.
● Reset
After a loop in the network has been eliminated, click this button "Reset to reset the port
again.
Changing the configured port status with loop detection
The configuration of the port status can be changed with the "Loop Detection" function. If, for
example, the administrator has disabled a port, the port can be enabled again after a device
restart with "Loop Detection". The port status "link down" is not changed by "Loop Detection".
5.5.10
Link aggregation
Bundling network connections for redundancy and higher bandwidth
Link aggregations according to IEEE 802.3ad allow several connections between
neighboring devices to be bundled to achieve higher bandwidths and protection against
failure.
Ports on both partner devices are included in link aggregations and the devices are then
connected via these ports. To assign ports (in other words links) correctly to a partner
device, the Link Aggregation Control Protocol (LACP) from the IEEE 802.3ad standard is
used.
Up to 8 link aggregations can be defined. A maximum of 8 ports can be assigned to each link
aggregation.
Note
When a port is assigned to a link aggregation but is not active (e.g. link down), the values
displayed may differ from the values configured for the link aggregation.
If the port in the link aggregation becomes active, individual port configurations such as DCP
forwarding are overwritten with the configured values of the link aggregation.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
263
Configuring with Web Based Management
5.5 The "Layer 2" menu
Display of the configured aggregation
The menu displays all the configured link aggregations.
Description of the displayed boxes
The table has the following columns:
● Select
Select the row you want to delete.
● Port
Shows the virtual port number of this link aggregation. This identifier is assigned internally
by the firmware.
● Link Aggregation Name
Shows the name of the link aggregation. This name can be specified by the user during
configuration. The name is not absolutely necessary but can be useful to distinguish
between the various link aggregations.
● MAC Address
Shows the MAC address.
● Status
Enable or disable link aggregation.
● MTU
Specify the packet size.
● LACP
– On
Enables the sending of LACP frames.
– Off
Disables the sending of LACP frames.
● Frame Distribution
Set the type of distribution of packets on the individual links of an aggregation.
– Destination&Source MAC
The distribution is based on a combination of the destination and source MAC
address.
– Destination&Source IP MAC
The distribution is based on a combination of the destination and source IP and MAC
address.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
264
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● VLAN Mode
Specify how the link aggregation is entered in a VLAN:
– Hybrid
The link aggregation sends tagged and untagged frames. It is not automatically a
member of a VLAN.
– Trunk
The link aggregation only sends tagged frames and is automatically a member of all
VLANs.
● Port
Shows the ports that belong to this link aggregation. The following values can be selected
from the drop-down list:
– "-" (disabled)
Link aggregation is disabled.
– "a" (active)
The port sends LACP frames and is only involved in the link aggregation when LACP
frames are received.
– "p" (passive)
The port is only involved in the link aggregation when LACP frames are received.
– o" (on)
The port is involved in the link aggregation and does not send any LACP frames.
Note
Within a "link aggregation", only ports with the following configuration are possible:
• all ports with "o"
• all ports with "a" or "p".
Steps in configuration
Basics prior to configuration
1. First, identify the ports you want to put together to form a link aggregation between the
devices.
2. Configure the link aggregation on the devices.
3. Adopt the configuration for all devices.
4. Perform the last step, the cabling.
Note
If you cable aggregated links prior to configuration, it is possible that you will create loops
in the network! The network involved may deteriorate badly due to this or complete
disruption may occur.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
265
Configuring with Web Based Management
5.5 The "Layer 2" menu
Creating a new link aggregation
1. Click the "Create" button to create a new link aggregation.
This creates a new row.
2. Select the ports that will belong to this link aggregation.
3. Click the "Set Values" button.
Deleting an aggregation
1. Using the check box at the beginning of a row, select the link aggregation you want to
delete.
2. Click the "Delete" button.
Changing an aggregation
1. In the overview, click on the relevant table entry to change the configuration of a created
link aggregation.
2. Make all the changes.
3. Click the "Set Values" button.
5.5.11
DCP forwarding
Applications
The DCP protocol is used by STEP 7 and the PST Tool for configuration and diagnostics.
When shipped, DCP is enabled on all ports; in other words, DCP frames are forwarded at all
ports. With this option, you can disable the sending of these frames for individual ports, for
example to prevent individual parts of the network from being configured with the PST Tool
or to divide the full network into smaller parts for configuration and diagnostics.
Note
PNIO configuration
Since DCP is a PROFINET protocol, the configuration created here is only effective with the
VLAN associated with the TIA interface.
All the ports of the device are displayed on this page. After each displayed port, there is a
drop-down list for function selection.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
266
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. If "No Change is selected, the entry in table 2
remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the available ports. The port is made up of the module number and the port
number, for example port 0.1 is module 0, port 1.
● Setting
From the drop-down list, select whether the port should block or forward outgoing DCP
frames. You have the following options available:
– Forward
DCP frames are forwarded via this port.
– Block
No outgoing DCP frames are forwarded via this port. It is nevertheless still possible to
receive via this port.
Steps in configuration
1. From the options in the drop-down list in the row, select which ports should support
sending DCP frames.
2. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
267
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.12
LLDP
Identifying the network topology
LLDP (Link Layer Discovery Protocol) is defined in the IEEE 802.AB standard.
LLDP is a method used to discover the network topology. Network components exchange
information with their neighbor devices using LLDP.
Network components that support LLDP have an LLDP agent. The LLDP agent sends
information about itself and receives information from connected devices at periodic
intervals. The received information is stored in the MIB.
Applications
PROFINET uses LLDP for topology diagnostics. In the default setting, LLDP is enabled for
all ports; in other words, LLDP frames are sent and received on all ports. With this function,
you have the option of enabling or disabling sending and/or receiving per port.
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Setting
Select the setting from the drop-down list. If "No Change" is selected, the entry in table 2
remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
268
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● Port
Shows the port.
● Settting
From the drop-down list, select whether or not the port will send or receive LLDP frames.
You have the following options available:
– Rx
This port can only receive LLDP frames.
– Tx
This port can only send LLDP frames.
– Rx & Tx
This port can receive and send LLDP frames.
– "-" (disabled)
This port can neither receive nor send LLDP frames.
Steps in configuration
1. From the drop-down list in the row of the port you want to configure, select the LLDP
functionality.
2. Click the "Set Values" button.
5.5.13
Fiber Monitoring Protocol
Requirements
● To be able to use the fiber monitoring function, enable LLDP. The fiber monitoring
information is appended to the LLDP packets.
● You can only use Fiber Monitoring with transceivers capable of diagnostics. Note the
documentation of the devices.
Monitoring optical links
With Fiber Monitoring, you can monitor the received power and the loss of power on optical
links between two switches.
If you enable fiber monitoring on an optical port, the device sends the current transmit power
of the port to its connection partner using LLDP packets. In addition to sending, the device
also checks whether corresponding information is received from the connection partner.
Regardless of whether the IE switch receives diagnostics information from its connection
partner, it monitors the received power measured at the optical port for the set limit values.
If fiber monitoring is enabled on the connection partner, the connection partner transfers the
current value for the transmit power of the port to the device. The device compares the value
it has received for the transmit power with the actually received power. The difference
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
269
Configuring with Web Based Management
5.5 The "Layer 2" menu
between the received power and the transmit power represents the power loss on the link.
The calculated power loss is also monitored for the set limit values.
If the value of the received power or the power loss falls below or exceeds the set limit
values, an event is triggered. You can set limit values in two stages for messages with the
severity levels "Warning" and "Critical".
In "System > Events > Configuration", you can specify how the IE switch indicates the event.
Note
If you have enabled fiber monitoring and a pluggable transceiver with diagnostics capability
is pulled, fiber monitoring is automatically disabled for this port and the set limit values and a
possibly pending error status are deleted.
Description of the displayed boxes
In the first table you can specify the limit values for the measured received power and the
calculated power loss to be monitored.
● Port
Shows the optical ports that support fiber monitoring. This depends on the transceivers.
● Status
Enable or disable fiber monitoring.
As default, the function is disabled.
● Rx Power [dBm] maintenance required (warning)
Specify the value at which you are informed of the deterioration of the received power by
a message of the severity level "Warning"
The default value depends on the relevant pluggable transceiver.
● Rx Power [dBm] maintenance demanded (critical)
Specify the value at which you are informed of the deterioration of the received power by
a message of the severity level "Critical"
The default value depends on the relevant pluggable transceiver.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
270
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Power Loss [dB] maintenance required (warning)
Specify the value at which you are informed of the power loss of the connection by a
message of the severity level "Warning"
Default: -50 dB
● Power Loss [dB] maintenance demanded (critical)
Specify the value at which you are informed of the power loss of the connection by a
message of the severity level "Critical"
Default: -55 dB
Steps in configuration
Activating fiber monitoring
Follow the steps below to activate the monitoring of a port:
1. Select the appropriate check box in the "Status" column.
2. For your setup, enter practical values value at which you want to be informed of
deterioration of the received power and the power loss of the connection.
3. Click the "Set Values" button.
Deactivating fiber monitoring
Follow the steps below to deactivate the monitoring of a port:
1. Deselect the appropriate check box in the "Status" column.
2. Click the "Set Values" button.
5.5.14
Unicast
5.5.14.1
Filtering
Address filtering
This table shows the unicast addresses entered statically by the user during parameter
assignment.
On this page, you also define the static unicast filters.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
271
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
The page contains the following boxes:
● VLAN ID
Select the VLAN ID in which you configure a new static MAC address. If nothing is set,
"VLAN1" is set as the basic setting.
● MAC Address
Enter the MAC address here.
This table contains the following columns:
● Select
Select the row you want to delete.
● VLAN ID
Shows the VLAN ID assigned to this MAC address.
● MAC Address
Shows the MAC address of the node that the device has learned or the user has
configured.
● Status
Shows the status of each address entry:
– Static
Configured by the user. Static addresses are stored permanently; in other words, they
are not deleted when the aging time expires or when the switch is restarted.
– Invalid
These values are not evaluated.
● Port
Shows the port via which the node with the specified address can be reached. Frames
received by the device whose destination address matches this address will be forwarded
to this port.
Note
You can only specify one port for unicast addresses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
272
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
To edit the entries, follow the steps below.
Creating a new entry
1. Select the relevant VLAN ID.
2. Enter the MAC address in the "MAC address" input box.
3. Click the "Create" button to create a new entry in the table.
4. Click the "Refresh" button.
5. Select the relevant port from the drop-down list.
6. Click the "Set Values" button.
Changing the entry
1. Select the relevant port.
2. Click the "Set Values" button.
Deleting an entry
1. Select the check box in the row to be deleted.
Repeat this for all entries you want to delete.
2. Click the "Delete" button to delete the selected entries from the filter table.
3. Click the "Refresh" button.
5.5.14.2
Locked ports
Activating the access control
On this page, you can block individual ports for unknown nodes.
If the Port Lock function is enabled, packets arriving at this port from unknown MAC
addresses are discarded immediately. Packets from known nodes are accepted by the port.
Since ports with the Port Lock function enabled cannot learn any MAC addresses, learned
addresses on these ports are automatically deleted after the Port Lock function is enabled.
The port accepts only static MAC addresses that were created previously either manually or
with the "Start Learning" function and the "Stop Learning" function.
To enter all connected nodes automatically, there is a function for automatic learning (see
"Layer 2 > Unicast > Learning").
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
273
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
Enables the port lock function.
– disabled
Disables the port lock function.
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
This column lists all the ports available on this device.
● Setting
Enable or disable access control for the port.
Steps in configuration
Enabling access control for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
274
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Enabling access control for all ports
1. In the "Setting" drop-down list, select the "Enabled" entry.
2. Click the "Copy to table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
5.5.14.3
Learning
Starting/stopping learning
With the automatic learning function, all connected devices are automatically entered in the
unicast filter table. As long as the "Start learning" function is enabled, all learned unicast
addresses are created immediately as static unicast entries.
The learning process is ended only after clicking the "Stop learning" button. With this
method, learning can take a few minutes or several hours in larger networks before all nodes
have really been learned. Only nodes that send packets during the learning phase are found.
By subsequently enabling the Port Lock function, only packets from the nodes known after
the end of the learning phase (static unicast entries) will be accepted at the relevant ports.
Note
If the Port Lock function was already active on individual ports prior to the automatic learning
phase, no addresses will be learned on these ports. This makes it possible to restrict
learning to certain ports. To do this, first enable the Port Lock function of the ports that are
not intended to learn addresses.
Steps in configuration
Learning addresses
1. Click the "Start learning" button to start the learning phase.
After starting the learning phase, the "Start learning" button is replaced by the "Stop
learning" button.
The device now enters the addresses of connected devices until you stop the function.
2. Click the "Stop learning" button to stop the learning function.
The button is once again replaced by the "Start learning" button. The learned entries are
stored.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
275
Configuring with Web Based Management
5.5 The "Layer 2" menu
Deleting all static unicast addresses
1. Click the "Clear all static unicast addresses" button to delete all static entries.
In large networks with numerous nodes, automatic learning may lead to a lot of undesired
static entries. To avoid having to delete these individually, this button can be used to
delete all static entries. This function is disabled during automatic learning.
Note
Depending on the number of entries involved, deleting may take some time.
5.5.14.4
Unicast blocking
Blocking forwarding of unknown unicast frames
On this page, you can block the forwarding of unknown unicast frames for individual ports.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
276
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
Blocking of unicast frames is enabled.
– disabled
Blocking of unicast frames is disabled.
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
All available ports are listed in this column. Unavailable ports are not displayed.
● Setting
Enable or disable the blocking of unicast frames.
Steps in configuration
Enabling blocking for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
Enabling blocking for all ports
1. In the "Setting" drop-down list, select the "Enabled" entry.
2. Click the "Copy to table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
5.5.15
Multicast
5.5.15.1
Groups
Multicast applications
In the majority of cases, a frame is sent with a unicast address to a particular recipient. If an
application sends the same data to several recipients, the amount of data can be reduced by
sending the data using one multicast address. For some applications, there are fixed
multicast addresses (NTP, IETF1 Audio, IETF1 Video etc.).
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
277
Configuring with Web Based Management
5.5 The "Layer 2" menu
Reducing network load
In contrast to unicast frames, multicast frames represent a higher load for the device.
Generally, multicast frames are sent to all ports. There are three ways of reducing the load
caused by multicast frames:
● Static entry of the addresses in the multicast filter table.
● Dynamic entry of the addresses by listening in on IGMP/MLD parameter assignment
frames (IGMP/MLD configuration).
● Active dynamic assignment of addresses by GMRP frames.
The result of all these methods is that multicast frames are sent only to ports for which an
appropriate address is entered.
The "Multicast" menu item, shows the multicast frames currently entered in the filter table
and their destination ports that the user set in the parameters.
Configuring multicast addresses
Description of the displayed boxes
The page contains the following boxes:
● VLAN ID
If you click on this text box, a drop-down list is displayed. Here you can select the VLAN
ID of a new MAC address you want to configure.
● MAC address
Here you enter a new MAC multicast address you want to configure.
The table has the following columns:
● Select
Select the row you want to delete.
● VLAN ID
Here, the VLAN ID of the VLAN is displayed to which the MAC multicast address of this
row is assigned.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
278
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● MAC address
Here, the multicast address is displayed that the device has learned or the user has
configured.
● Status - static
Shows the status of each address entry. The address was entered statically by the user.
Static addresses are stored permanently; in other words, they are not deleted when the
aging time expires or when the device is restarted. These must be deleted by the user.
● Port List
There is a column for each slot. Within a column, the multicast group to which the port
belongs is shown. The drop-down list provides the following options:
– M
(Member) Multicast frames are sent via this port.
– F
(Forbidden) Not a member of the multicast group. Moreover, this address must not be
an address learned dynamically with GMRP or IGMP/MLD.
– –
Not a member of the multicast group. No multicast frames with the defined multicast
MAC address are sent via this port.
Steps in configuration
Creating a new entry
Note
You cannot create any static multicast entries if GMRP is enabled.
1. Select the required VLAN ID from the ""drop-down list.
2. Enter the MAC address in the "MAC address" input box.
3. Click the "Create" button. A new entry is generated in the table.
4. Assign the relevant ports to the MAC address.
5. Click the "Set Values" button.
Creating layer 2 multicast addresses with a script and GMRP
If you want to create several layer 2 multicast addresses using a script, GMRP must be
disabled as long as the script is executing. Follow the steps outlined below:
1. If GMRP is enabled, disable it. You configure GMRP on the "Layer 2 > Multicast >
GMRP" page.
2. Run the script.
3. Enable GMRP only after the script has completed and the layer 2 multicast addresses
have been created.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
279
Configuring with Web Based Management
5.5 The "Layer 2" menu
Deleting an entry
1. Select the check box in the row to be deleted.
2. Click the "Delete" button.
The row is deleted from the display and from the memory of the device.
5.5.15.2
IGMP
Function
IE switches support "IGMP snooping" and the IGMP querier function. If "IGMP snooping" is
enabled, IGMP frames are evaluated and the multicast filter table is updated with this
information. If "IGMP Querier is also enabled, IE switches also send IGMP queries that
trigger responses from IGMP-compliant nodes.
IGMP Snooping Aging Time
In this menu, you can configure the aging time for IGMP Configuration. When the time
elapses, entries created by IGMP are deleted from the address table if they are not updated
by a new IGMP frame.
This applies to all ports; a port-specific configuration is not possible.
IGMP Snooping Aging Time depending on the querier
SCALANCE XR500 as IGMP querier
If a SCALANCE XR500 is used as an IGMP querier, the query interval is 125 seconds. For
the "IGMP Snooping Aging Time", set at least 250 seconds.
Other IGMP queriers
If a different IGMP querier is used, the value of the "IGMP Snooping Aging Time" should be
at least twice as long as the query interval.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
280
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
The page contains the following boxes:
● IGMP Snooping
Enable or disable IGMP (Internet Group Management Protocol). The function allows the
assignment of IP addresses to multicast groups. If the check box is selected, IGMP
entries are included in the table and IGMP frames are forwarded.
● IGMP Snooping Aging Time [s]
In this box, enter the value for the aging time in seconds. As default, 300 seconds is set.
Valid values: 130 - 300 (seconds)
● IGMP Querier
Enable or disable "IGMP Querier". The device sends IGMP queries.
Steps in configuration
1. Select the "IGMP Snooping" check box.
2. Enter the value for the aging time in seconds in the "IGMP Snooping Aging Time" box.
3. Select the "IGMP Querier" check box.
4. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
281
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.15.3
GMRP
Activating GMRP
By selecting the check box, you specify whether or not GMRP is used for each individual
port. If "GMRP" is disabled for a port, no registrations are made for it and it cannot send
GMRP frames.
Description of the displayed boxes
The page contains the following box:
● GMRP
Enable or disable the GMRP function.
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
Enables the sending of GMRP frames.
– disabled
Disables the sending of GMRP frames.
– No Change
Table 2 remains unchanged.
● Copy to table
If you click the button, the settings are adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
282
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● Port
This column shows all the ports available on the device as well as the link aggregations.
● Setting
With this check box, you enable or disable GMRP for each individual port or link
aggregation.
Steps in configuration
Enabling the sending of GMRP frames for an individual port
1. Select the "GMRP" check box.
2. Select the check box in the relevant row in table 2.
3. To apply the changes, click the "Set Values" button.
Enabling the sending of GMRP frames for all ports
1. Select the "GMRP" check box.
2. In the "Setting" drop-down list, select the "Enabled" entry.
3. Click the "Copy to table" button. The check box is enabled for all ports in table 2.
4. To apply the changes, click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
283
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.15.4
Multicast blocking
Disabling the forwarding of unknown multicast frames
On this page, you can block the forwarding of unknown multicast frames for individual ports.
Description of the displayed values
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
Blocking of multicast frames is enabled.
– disabled
Blocking of multicast frames is disabled.
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
All available ports are listed in this column. Unavailable ports are not displayed.
● Setting
Enable or disable the blocking of multicast frames.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
284
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Steps in configuration
Enabling blocking for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
Enabling blocking for all ports
1. In the "Setting" drop-down list, select the "Enabled" entry.
2. Click the "Copy to table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
5.5.15.5
MLD (IPv6)
Mulitcast Listener Discovery
Devices support "MLD snooping" and the "MLD querier" function. If "MLD snooping" is
enabled, MLD frames are evaluated and the multicast filter table is updated with this
information. If "IGMP querier is also enabled, IE switches also send MLD queries that trigger
responses from MLD-compliant nodes.
With MLD snooping, MLD frames are only forwarded to the intended multicast listeners
instead of being flooded to all ports.
For MLD snooping to work, you need to enable the function globally and in the VLANs.
MLD Snooping Aging Time
On this page, you can configure the aging time for MLD configuration. When the time
elapses, entries created by MLD are deleted from the address table if they are not updated
by a new MLD packet.
This applies to all VLANS; a VLAN-specific configuration is not possible.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
285
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description
The page contains the following:
● MLD Snooping
Enable or disable MLD on the device.
● MLD Snooping Aging Time
Enter the time after which entries generated by MLD are deleted from the multicast filter
table. Assuming that this is not updated by a new MLD packet.
This applies to all VLANS; a VLAN-specific configuration is not possible
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all VLANs of table 2.
● Snooping / Querier
Select the setting. You have the following setting options:
– enabled
The function is enabled.
– disabled
The function is disabled.
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the settings are adopted for all ports of table 2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
286
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 2 has the following columns:
● VLAN ID
Shows the VLAN to which the settings relate
● Snooping
Enable or disable MLD for the required VLAN. When enabled, the MLD entries are
included the multicast filter table and MLD packets are forwarded.
● Querier
Enable or disable "Querier". The device sends MLD queries.
Steps in configuration
Enabling the sending of MLD frames for a VLAN
1. Select the "MLD Snooping" check box.
2. Select the check box in the relevant row in table 2.
3. To apply the changes, click the "Set Values" button.
Enabling the sending of MLD frames for all VLANs
1. Select the "MLD Snooping" check box.
2. Select the entry "enabled" in the "Snooping" and"Querier" drop-down lists.
3. Click the "Copy to table" button. The check box is enabled for all VLANs in table 2.
4. To apply the changes, click the "Set Values" button.
5.5.16
Broadcast
Blocking the forwarding of broadcast frames
On this page, you can block the forwarding of broadcast frames for individual ports.
Note
Some communication protocols work only with the support of broadcast. In these cases,
blocking can lead to loss of data communication. Block broadcast only when you are sure
that you do not need it.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
287
Configuring with Web Based Management
5.5 The "Layer 2" menu
Description of the displayed boxes
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● Setting
Select the setting from the drop-down list. You have the following setting options:
– enabled
The blocking of broadcast frames is enabled.
– disabled
The blocking of broadcast frames is disabled.
– No Change
Table 2 remains unchanged.
● Copy to Table
If you click the button, the setting is adopted for all ports of table 2.
Table 2 has the following columns:
● Port
All available ports and the link aggregations are shown.
● Setting
Enable or disable the blocking of broadcast frames.
Steps in configuration
Enabling the blocking of broadcast frames for an individual port
1. Select the check box in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
288
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
Enabling the blocking of broadcast frames for all ports
1. In the "Setting" drop-down list, select the "Enabled" entry.
2. Click the "Copy to table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
5.5.17
PTP
5.5.17.1
General
The following devices support time-of-day synchronization using PTP:
● SCALANCE XR528-6M
● SCALANCE XR552-12M
IEEE 1588 with SCALANCE devices
The IEEE 1588v2 standard defines mechanisms with which highly precise time of day
synchronization of devices in a network can be achieved. SCALANCE devices with suitable
hardware support time synchronization according to IEEE 1588v2. The functionality is
disabled on these devices when they are shipped and following a "Reset to factory defaults".
To be able to use PTP, enable this function and configure every port that is on the
synchronization path as well as ports that are blocked due to redundancy mechanisms. PTP
can also be used with redundancy mechanisms in the ring such as HRP, standby linking of
rings, MRP and RSTP. The following sections describe the configuration options of Web
Based Management.
1588 Configuration
On this page, you specify how the device will process PTP messages.
1588 Mode
You can make the following settings:
● off
The device does not process any PTP messages. PTP messages are, however,
forwarded according to the rules of the switch.
● transparent
The device adopts the function of a transparent clock and forwards PTP messages to
other nodes while at the same time making entries in the correction field of the PTP
message.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
289
Configuring with Web Based Management
5.5 The "Layer 2" menu
5.5.17.2
TC General
TC General
On this tab, you will find the general settings for PTP.
1588 Transparent Clock Configuration
Delay Mechanism
Specify the delay mechanism the device will work with:
● end to end
(Delay request response mechanism will be used)
Note
With end-to-end synchronization with more than 2 slaves, freak values > 100 ns can
occur in the offset.
● peer to peer
(Peer delay mechanism will be used)
Domain Number
Enter the domain number for the device here. The device ignores PTP messages with a
different domain number. A SCALANCE device can only be assigned to one synchronization
domain.
5.5.17.3
TC Port
TC port
This tab contains the port settings for PTP.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
290
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
1588 Transparent Clock Port Parameters
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Setting
Select the required setting. If "No Change is selected, the entry in table 2 remains
unchanged.
● Transport Mechanism
The following settings are possible:
– Ethernet
– UDP IPv4
– No Change
If "No Change is selected, the entry in table 2 remains unchanged.
Table 2 shows detailed information about the individual ports:
● Port
The port number. With modular devices, the slot number and port number are displayed
separated by a dot.
● Setting
The port status. The following entries are possible:
– disabled
The port is not involved in PTP.
– enabled
The port processes PTP messages.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
291
Configuring with Web Based Management
5.5 The "Layer 2" menu
● Faulty Flag
The error status relating to PTP.
– true
An error occurred.
– false
No error has occurred on this port.
● Transport mechanism
Choose how this port will handle PTP message data traffic. You can make different
settings for the ports of a device, however, the relevant communications partner must
support the selected transport mechanism. The following settings are possible:
– Ethernet
– UDP IPv4
5.5.18
RMON
5.5.18.1
Statistics
Statistics
On this page you can specify the ports for which RMON statistics are displayed.
The RMON statistics are displayed on the "Information > Ethernet Statistics" page on the
"Packet Size", "Packet Type" and "Packet Error" tabs.
Settings
SCALANCE XM-400/XR-500 Web Based Management (WBM)
292
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.5 The "Layer 2" menu
● RMON
If you select this check box, Remote Monitoring (RMON) allows diagnostics data to be
collected on the device, prepared and read out using SNMP by a network management
station that also supports RMON. This diagnostic data, for example port-related load
trends, allow problems in the network to be detected early and eliminated.
Note
If you disable RMON, these statistics are not deleted but retain their last status.
● Port
Select the ports for which statistics will be displayed.
The table has the following columns:
● Select
Select the row you want to delete.
● Port
Shows the ports for which statistics will be displayed.
5.5.18.2
History
Samples of the statistics
On this page, you can specify whether or not samples of the statistics are saved for a port.
You can specify how many entries should be saved and at which intervals samples should
be taken.
Settings
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
293
Configuring with Web Based Management
5.5 The "Layer 2" menu
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports.
● Setting
Select the required setting. If "No Change" is selected, the entry in table 2 remains
unchanged.
● Entries
Enter the maximum number of samples to be stored at the same time. If "No Change" is
entered, the entry in table 2 remains unchanged.
● Interval [s]
Enter the interval after which the current status of the statistics will be saved as a sample.
If "No Change" is entered, the entry in table 2 remains unchanged.
● Copy to Table
If you click the button, the settings are adopted for all ports of table 2.
Table 2 has the following columns:
● Port
Shows the port to which the settings relate.
● Setting
Enable or disable the recording of the history on the relevant port.
● Entries
Enter the maximum number of samples to be stored at the same time.
● Interval [s]
Enter the interval after which the current status of the statistics will be saved as a sample.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
294
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6
The "Layer 3 (IPv4)" menu
5.6.1
Configuration
Introduction
The page contains the overview of the layer 3 functions for IPv4 of the device. On this page,
you enable or disable the required layer 3 function.
The functions "Routing", "VRRP", "RIP" and "OSPF" are only available with layer 3.
Description of the displayed boxes
The page contains the following boxes:
● Routing (only available with devices with a layer 3 license)
– Enabled
IPv4 routing is enabled. You can only enable the routing function if DHCP is disabled
on all configured interfaces.
– Disabled
IPv4 routing is disabled. If IPv6 routing is enabled, this is also disabled.
● DHCP Relay Agent
Enable or disable the DHCP relay agent. You can configure other settings in "Layer 3
(IPv4) > DHCP Relay Agent".
● VRRP (only available with devices with a layer 3 license)
Enable or disable routing using VRRP. To use VRRP, first enable the routing function.
You can configure other settings in "Layer 3 (IPv4) > VRRP".
● OSPF (only available with devices with a layer 3 license)
Enable or disable routing using OSPF. To use OSPF, first enable the "Routing" function.
You can configure other settings in "Layer 3 (IPv4) > OSPF".
● RIP (only available with devices with a layer 3 license)
Enable or disable routing using RIP. To use RIP , first enable the routing function. You
can configure other settings in "Layer 3 (IPv4) > RIP".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
295
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Steps in configuration
1. To use the required function, select the corresponding check box.
2. Click the "Set Values" button.
5.6.2
Subnets
5.6.2.1
Overview
Creating subnets
The page shows the subnets for the selected interface. If more than one subnet is available
on an interface, in the first entry of this interface is of the address type "Primary".
All other subnets are created on this page. A subnet always relates to an interface. The
interface is created on the "Configuration" tab.
Description of the displayed values
The page contains the following boxes:
● Interface
Select the interface on which you want to configure another subnet.
The table has the following columns:
● Select
Select the row you want to delete.
● Interface
Shows the interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
296
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● TIA Interface
Shows the selected TIA interface.
● Interface Name
Shows the name of the interface.
● MAC Address
Shows the MAC address.
● IP Address
Shows the IPv4 address of the subnet.
● Subnet Mask
Shows the subnet mask.
● Address Type
Displays the address type. The following values are possible:
– Primary
The first IPv4 address that was configured on an IPv4 interface.
– Secondary
All other IPv4 address that were configured on an IPv4 interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
297
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● IP Assgn Method
Shows how the IPv4 address is assigned. The following values are possible:
– Static
The IPv4 address is static. You enter the settings in "IP Address" and "Subnet Mask".
– Dynamic (DHCP)
The device obtains a dynamic IPv4 address from a DHCPv4 server.
● Address Collision Detection Status
If new IPv4 addresses become active in the network, the "Address Collision Detection"
function checks whether this can result in address collisions. The allows IPv4 addresses
that would be assigned twice to be detected.
Note
The function does not run a cyclic check.
This column shows the current status of the function. The following values are possible:
– Idle
The interface is not enabled and does not have an IPv4 address.
– Starting
This status indicates the start-up phase. In this phase, the device initially sends a
query as to whether the planned IPv4 address already exists. If the address is not yet
been assigned, the device sends the message that it is using this IP address as of
now.
– Conflict
The interface is not enabled. The interface is attempting to use an IPv4 address
address that has already been assigned.
– Defending
The interface uses a unique IPv4 address. Another interface is attempting to use the
same IPv4 address.
– Active
The interface uses a unique IPv4 address. There are no collisions.
– Not supported
The function for detection of address collisions is not supported.
– Disabled
The function for detection of address collisions is disabled.
Steps in configuration
1. Select the interface from the "Interface" drop-down list.
2. Click the "Create" button. A new row is inserted in the table.
3. Click the "Set Values" button. Configure the subnet on the "Configuration" tab.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
298
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.2.2
Configuration
On this page, you configure the IPv4 interface.
Description of the displayed values
The page contains the following boxes:
● Interface (name)
Select the interface from the drop-down list.
● Interface Name
Enter the name of the interface.
● MAC Address
Displays the MAC address of the selected interface.
● DHCP
Enable or disable the DHCP client for this IPv4 interface.
Note
If you want to operate the device as a router with several interfaces, disable DHCP on all
interfaces.
● IP Address
Enter the IPv4 address of the interface. The IPv4 addresses must not be used more than
once.
● Subnet Mask
Enter the subnet mask of the subnet you are creating. Subnets on different interfaces
must not overlap.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
299
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Address Type
Shows the address type. The following values are possible:
– Primary
The first subnet of the interface.
– Secondary
All further subnets of the interface.
● TIA Interface
Select whether or not this interface should become the TIA Interface.
Steps in configuration
1. Select the interface from the "Interface (name)" drop-down list.
2. Enter a name for the Interface in "Interface Name".
3. Enter the IP address of the subnet in the "IP Address" column.
4. Enter the subnet mask belonging to the IPv4 address in the "Subnet Mask" column
5. Click the "Set Values" button.
5.6.3
Static Routes
Static route
On this page, you create the static IPv4 routes.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
300
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description of the displayed values
The page contains the following boxes:
● Destination Network
Enter the network address of the destination that can e reached via this route.
● Subnet Mask
Enter the corresponding subnet mask.
● Gateway
Enter the IPv4 address of the gateway via which this network address is reachable.
● Metric
Enter the metric for the route. The metric corresponds to the quality of a connection,
based for example on speed or costs. If there are several equal routes, the route with the
lowest metric value is used.
Range of values: 1 - 254
The table has the following columns:
● Select
Select the row you want to delete.
● Destination Network
Shows the network address of the destination.
● Subnet Mask
Shows the corresponding subnet mask.
● Gateway
Shows the IPv4 address of the next gateway.
● Interface
Shows the interface of the route.
● Metric
Enter the metric for the route. When creating the route, "not used" is entered
automatically. The metric corresponds to the quality of a connection, based for example
on speed or costs. If there are several equal routes, the route with the lowest metric value
is used.
Range of values: 1 - 254
● Status
Shows whether or not the route is active.
Steps in configuration
1. Enter the network address of the destination in the "Destination Network" input box.
2. Enter the corresponding subnet mask in the "Subnet Mask" input box.
3. Enter the gateway in the "Gateway" input box.
4. Enter the weighting of the route in "Metric".
5. Click the "Create" button. A new entry is generated in the table.
6. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
301
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.4
Route Maps
5.6.4.1
General
Route maps
With route maps, you control how routing information is further processed. You can filter
routing information and specify whether the information is further processed, modified or
discarded.
Route maps operate according to the following principle:
● Routing information is compared with the filters of the route maps.
● The comparison is continued until the filters of a route map match the properties of an
item of information.
● The information is then processed according to the route map settings:
– The routing information is discarded.
– The properties of the routing information are changed.
Settings
Figure 5-10
Route maps general
● Name
Enter the name for the route map.
● Sequence Number
Enter a number for the route map.
You can create several route maps with the same name but with different sequence
numbers. The sequence numbers then specify the order in which the route maps are
processed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
302
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
The table has the following columns:
● Select
Select the row you want to delete.
● Name
Shows the name of the route map.
● Sequence Number
Shows the sequence number of the route map.
● Action
Specify what happens to the routing information that matches the settings of the route
map:
– permit
The routing information is further processed according to the settings you make in the
"Set" tab.
– deny
The routing information is discarded.
5.6.4.2
Interface & Value Match
On this page, you specify whether or not the routing information for a route map is filtered
according to interfaces, metric or tags.
Settings
Figure 5-11
Filtering route maps and metric
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
303
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Route Map (Name/Seq. No.)
Select a route map.
The created route maps are available to you.
● Type
Select the basis for the filtering:
– Interface
– Metric
– Tag
● Interface
Select an interface.
This box is active only if you have selected the "Interface" entry in the "Type" drop-down
list.
● Metric
Enter a value for the metric.
This box is active only if you have selected the "Metric" entry in the "Type" drop-down list.
● Tag
Enter a value for the tag.
This box is active only if you have selected the entry "Tag in the "Type" drop-down list.
The table has the following columns:
● Select
Select the row you want to delete.
● Type
Shows the selected type:
– Interface
– Metric
– Tag
● Value
Shows the selected interface or the value of the metric or of the tag.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
304
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.4.3
Destination Match
On this page, you specify whether or not the routing information for a route map is filtered
based on the destination IPv4 address.
Settings
Figure 5-12
Route Maps Destination Match
● Route Map (Name/Seq. No.)
Select a route map.
● IP Address
Enter the IPv4 address of the destination on which the filtering is based.
● Subnet Mask
Enter the subnet mask of the destination on which the filtering is based.
The table has the following columns:
● Select
Select the row you want to delete.
● IP Address
Shows the IPv4 address of the destination.
● Subnet Mask
Shows the subnet mask of the destination.
5.6.4.4
Next Hop Match
On this page, you specify whether or not the filtering for a route map will be based on the
router to which the routing information is sent next.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
305
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Settings
Figure 5-13
Route Maps Next Hop Match
● Route Map (Name/Seq. No.)
Select a route map.
● IP Address
Enter the IP address of the router to which the routing information will be sent next.
The table has the following columns:
● Select
Select the row you want to delete.
● IP Address
Shows the IP address of the next router.
5.6.4.5
Create
On this page, you specify whether or not the routing information will be changed by a route
map.
You can only change the information of a "Permit" route map.
If, for example, you have filtered based on a certain metric, you can change the value of the
metric here. The routing information is then forwarded with the new value.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
306
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Settings
Figure 5-14
Route maps set
● Route Map (Name/Seq. No.)
Select a route map.
The table has the following columns:
● Select
Select the row you want to delete.
● Name
Shows the name of the route map.
● Sequence Number
Shows the sequence number of the route map.
● Metric
Enter the new value for the metric with which the routing information will be forwarded.
● Tag
Enter the new value for the tag with which the routing information will be forwarded.
5.6.5
DHCP Relay Agent
5.6.5.1
General
DHCP Relay Agent
If the DHCP server is in a different network, the device cannot reach the DHCP server. The
DHCP relay agent intercedes between a DHCP server and the device. The DHCP relay
agent forwards the port number of the device with the DHCP query to the DHCP server.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
307
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
You can specify up to 4 DHCP server IPv4 addresses for the DHCP relay agent. If a DHCP
server is unreachable, the device can switch to a different DHCP server.
Description of the displayed values
The page contains the following boxes:
● DHCP Relay Agent (opt. 82)
Enable or disable the DHCP relay agent
● Server IP Address
Enter the IPv4 address of the DHCP server.
The table has the following columns:
● Select
Select the row you want to delete.
● Server IP Address
Shows the IPv4 address of the DHCP server.
Steps in configuration
1. Enter the IPv4 address of the DHCP server in the "Server IP Address" input box.
2. Click the "Create" button. A new entry is generated in the table.
3. Select the "DHCP Relay Agent (Opt. 82)" check box.
4. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
308
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.5.2
Option
Parameters of the DHCP relay agent
On this page, you can specify parameters for the DHCP server, for example the circuit ID.
The circuit ID describes the origin of the DHCP query, for example which port received the
DHCP query.
You specify the DHCP server on the "General" tab.
Description of the displayed values
The page contains the following boxes:
Global configuration
● Circuit ID router index
Enable or disable the check box. If you enable the check box, the generated circuit ID of
the has the router index added to it.
● Circuit ID Receive VLAN ID
Enable or disable the check box. If you enable the check box, the VLAN ID is added to
the generated circuit ID
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
309
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Circuit ID Receive Port
Enable or disable the check box. If you enable the check box, the generated circuit ID
has the receiving port added to it.
Note
You need to select a least one option.
● Remote ID
Shows the device ID.
Interface-specific configuration
● Interface
Select the interface from the drop-down list.
The table has the following columns:
● Select
Select the row you want to delete.
● Interface
Shows the interface.
Note
If you have not created an interface-specific configuration, the global configuration with
the MAC address is used as the device ID.
● Remote ID Type
Select the type of device ID from the drop-down list. You have the following options:
– IP Address
The IPv4 address of the device is used as the device ID.
– MAC Address
The MAC address of the device is used as the device ID.
– Free Text
If you use "Free Text", you can enter the device name as the device ID in "Remote
ID".
● Remote ID
Enter the device name. The box can only be edited if you select the entry "Free Text" for
"Remote ID Type".
● Circuit ID Type
Select the type of circuit ID from the drop-down list. You have the following options:
– Predefined
The circuit ID is created automatically based on the router index, VLAN ID or port.
– Free Number
If you use "Free Number", you can enter the ID for "Circuit ID".
● Circuit ID
Enter the circuit ID. The box can only be edited if you select the "Free number" entry for
the "Circuit ID Type".
Range of values: 1- 188
SCALANCE XM-400/XR-500 Web Based Management (WBM)
310
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Steps in configuration
Follow the steps below to specify automatic assignment of the parameters:
1. Select the "Circuit ID router index" check box.
2. Select the interface from the "Interface" drop-down list.
3. Click the "Create" button. A new row is inserted in the table
4. Select the "IP Address" entry in the "Remote ID Type" drop-down list. The IPv4 address
is used as the device ID.
5. Select the "Predefined" entry in the "Circuit ID Type" drop-down list. The router index is
added to the generated Circuit ID.
6. Click the "Set Values" button.
Follow the steps below to specify the parameters manually:
1. Select the "Circuit ID router index" check box.
2. Select the interface from the "Interface" drop-down list.
3. Click the "Create" button. A new row is inserted in the table
4. Select the "Free Text" entry in the "Remote ID Type" drop-down list. Enter the device ID
in "Remote ID".
5. Select the "Free Number" entry in the "Circuit ID Type" drop-down list. Enter the ID in
"Circuit ID".
6. Click the "Set Values" button.
5.6.6
VRRP
5.6.6.1
Router
Introduction
Using the "Create" button, you can create new virtual routers. A maximum of 52 Virtual
routers can be configured. You can configure other parameters on the "Configuration" tab.
Note
• This function is available only with layer 3.
• Select the "VRRP" check box to configure VRRP.
• Simultaneous operation of VRRP and VRRPv3 is not possible.
• You can only use VRRP in conjunction with VLAN interfaces. Router ports are not
supported.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
311
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description of the displayed values
The page contains the following boxes:
● VRRP
Enable or disable routing using VRRP.
● Reply to pings on virtual interfaces
When enabled, the virtual IP addresses also reply to the ping.
● Interface
Select the VLAN Interface that functions as the virtual router from the drop-down list.
● VRID
Enter the ID of the virtual router in the input box. This ID defines the group of routers that
form a virtual router (VR). In the group, this is the same. It can no longer be used for
other groups.
Valid values are 1.. 255.
The table has the following columns:
● Select
Select the row you want to delete.
● Interface
Shows the Interface that functions as the virtual router.
● VRID
Shows the ID of the virtual router.
● Virtual MAC Address
Shows the virtual MAC address of the virtual router.
● Primary IP Address
Shows the numerically lowest IPv4 address in this VLAN. The entry 0.0.0.0 means that
the "Primary" address on this VLAN is used. Otherwise all IPv4 addresses configured on
this VLAN in the "Layer 3 (IPv4) > Subnets" menu are valid values.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
312
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Router State
Shows the current status of the virtual router. Possible values are:
– Master
The router is the Master router and handles the routing functionality for all assigned IP
addresses.
– Backup
The router is the backup router. If the master router fails, the backup router takes over
the tasks of the master router.
– Initialize
The virtual router has just been turned on. It will soon change to the "Master" or
"Backup" state.
● Master IP Address
Shows the IPv4 address of the master router.
● Priority
Shows the priority of the virtual router.
Valid values are 1-255.
If an IPv4 address is assigned to the VRRP router that is also actually configured on the
local IPv4 interface, the value 255 is entered automatically. All other priorities can be
distributed freely among the VRRP routers. The higher the priority, the earlier the VRRP
router becomes "Master".
● Advert. Interval
Shows the interval at which the master router sends VRRP packets.
● Preempt
Shows the precedence of a router when changing roles between backup and master.
– yes
This router has precedence when changing roles.
– no
This router does not have precedence when changing roles.
Steps in configuration
1. Select the "VRRP" check box.
2. Select the interface from the "Interface" drop-down list.
3. Enter the ID of the virtual router in the "VRID" input box.
4. Select the "Reply to pings on virtual interfaces" check box so that virtual IP addresses
reply to pings as well.
5. Click the "Create" button. A new row is inserted in the table.
6. Click the "Set Values" button. To configure the virtual router, click on the "Configuration"
tab.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
313
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.6.2
Configuration
Introduction
On this page, you configure the virtual router.
Note
This function is available only with layer 3.
Description of the displayed values
The page contains the following boxes:
● Interface / VRID
Select the ID of the virtual router you are configuring from the drop-down list.
● Primary IP Address
Select the numerically lowest IPv4 address from the drop-down list: If the router becomes
master router, the router uses this IPv4 address.
Note
If you only configure one subnet on this VLAN, no entry is necessary. The entry is then
0.0.0.0.
If you configure more than one subnet on the VLAN and you want a specific IPv4 address
to be used as the source address for VRRP packets, select the IPv4 address from the
drop-down list. Otherwise, the numerically lowest IPv4 address will be used.
● Master
If this option is enabled, the numerically lowest IPv4 address is entered for "Associated IP
Address". This means that the highest priority IPv4 address of the VRRP router is used
as the virtual IPv4 address of the virtual master router. The option must be disabled for
the backup routers in this group and the IP address of the router in "Associated IP
address" must be used.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
314
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Priority
Enter the priority of this virtual router. Valid values are 1-255.
If an IPv4 address is assigned to the VRRP router that is also actually configured on the
local IPv4 interface, the value 255 is entered automatically. All other priorities can be
distributed freely among the VRRP routers. The higher the priority, the earlier the VRRP
router becomes "Master".
● Advertisement Interval
Enter the interval in seconds after which a master router sends a VRRP packet again.
● Preempt lower priority Master
Allow the precedence when changing roles between backup and master based on the
selection process.
Steps in configuration
To configure a virtual router as the master router, follow the steps below:
1. Select the ID of the virtual router you want to configure from the "Interface / VRID" dropdown list.
2. Select the "Status" check box.
3. Select the source address from the "Primary IP Address" drop-down list.
4. From the "Priority" drop-down list, enter the priority of this virtual router.
5. Select the "Master" check box.
6. Enter the interval in "Advertisement Interval".
7. Select the "Preempt lower priority Master" check box.
8. Click the "Set Values" button.
5.6.6.3
Address overview
Overview
This page shows which IPv4 addresses the virtual router monitors. Each virtual router can
monitor a maximum of 10 IPv4 addresses.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
315
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description of the displayed boxes:
The table has the following columns:
● Interface
Shows the Interface that functions as the virtual router.
● VRID
Shows the ID of this virtual router.
● Number of addresses
Shows the number of IPv4 addresses.
● Assigned IP address (1) ... Assigned IP address (10)
Shows the router IPv4 addresses monitored by this virtual router. If a router takes over
the role of master, the routing function is taken over by this router for all these IPv4
addresses.
5.6.6.4
Address Configuration
Creating or changing the monitored IPv4 addresses
On this page, you can create, modify or delete the IPv4 addresses to be monitored. A
maximum of 10 IPv4 addresses can be monitored by a virtual router.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
316
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description of the displayed values
The page contains the following boxes:
● Interface / VRID
Select the virtual router from the drop-down list.
● Associated IP address
Enter the IPv4 address that the virtual router will monitor.
A maximum of 10 IPv4 addresses are possible.
The table has the following columns:
● Select
Select the row you want to delete.
● Associated IP Address
Shows the IPv4 addresses that the virtual router monitors.
Steps in configuration
1. Select the ID of the virtual router from the "Interface / VRID" drop-down list.
2. Enter the IPv4 address that the virtual router will monitor.
3. Click the "Create" button. A new entry is generated in the table.
5.6.7
VRRPv3
5.6.7.1
Router
Introduction
Using the "Create" button, you can create new virtual routers. A maximum of 52 Virtual
routers can be configured. You can configure other parameters on the "Configuration" tab.
Note
• This function is available only with layer 3.
• Simultaneous operation of VRRP and VRRPv3 is not possible.
• Select the "VRRPv3" check box to configure VRRPv3.
• You can use VRRPv3 on VLAN interfaces. Router ports are not supported.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
317
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description
The page contains the following:
● VRRPv3
Enable or disable routing using VRRPv3. Can only be enabled when "Layer 3 >
Configuration" "IPv6 Routing" is enabled.
● Reply to pings on virtual interfaces
When enabled, the virtual IPv4 addresses also reply to the ping.
● Interface
Select the required VLAN interface operating as virtual router.
● VRID
Enter the ID of the virtual router. This ID defines the group of routers that form a virtual
router (VR). In the group, this is the same. It can no longer be used for other groups.
Valid values are 1.. 255.
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Interface
Shows the Interface that functions as the virtual router.
● VRID
Shows the ID of the virtual router.
● Virtual MAC Address
Shows the virtual MAC address of the virtual router.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
318
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Primary IP Address
Shows the numerically lowest IPv4 address in this VLAN. The entry 0.0.0.0 means that
the "Primary" address on this VLAN is used. Otherwise all IPv4 addresses configured on
this VLAN in the "Layer 3 (IPv4) > Subnets" menu are valid values.
● Router State
Shows the current status of the virtual router. Possible values are:
– Master
The router is the master router and handles the routing functionality for all assigned
IPv4 addresses.
– Backup
The router is the backup router. If the master router fails, the backup router takes over
the tasks of the master router.
– Initialize
The virtual router has just been turned on. It will soon change to the "Master" or
"Backup" state.
● Master IP Address
Shows the IPv4 address of the master router.
● Priority
Shows the priority of the virtual router.
Valid values are 1-254.
If an IPv4 address is assigned to the VRRP router that is also actually configured on the
local IPv4 interface, the value 255 is entered automatically. All other priorities can be
distributed freely among the VRRP routers. The higher the priority, the earlier the VRRP
router becomes "Master".
● Advert. Internal
Shows the interval at which the master router sends VRRPv3 packets.
● Preempt
Shows the precedence of a router when changing roles between backup and master.
– yes
This router has precedence when changing roles.
– no
This router does not have precedence when changing roles.
Steps in configuration
1. Enable "VRRPv3".
2. Select the required interface.
3. Enter the ID of the virtual router in "VRID".
4. Select the "Reply to pings on virtual interfaces" option so that virtual IPv4 addresses reply
to pings as well.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
319
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5. Click the "Create" button. A new row is inserted in the table.
6. Click the "Set Values" button. To configure the virtual router, click on the "Configuration"
tab.
5.6.7.2
Configuration
Introduction
On this page, you configure the virtual router.
Note
This function is available only with layer 3.
Description
The page contains the following:
● Interface / VRID
Select the ID of the virtual router to be configured.
● Primary Address
Select the primary IPv4 address. If the router becomes master router, the router uses this
IPv4 address.
Note
If you only configure one subnet on this VLAN, no entry is necessary. The entry is then
0.0.0.0.
If you configure more than one subnet on the VLAN and you want a specific IPv4 address
to be used as the source address for VRRP packets, select the IPv4 address. Otherwise,
the numerically lowest IPv4 address will be used.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
320
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Master
If enabled, the numerically lowest IPv4 address is entered for "Associated IP Address".
This means that the numerically lowest IPv4 address of the VRRP router is used as the
virtual IP address of the virtual master router. The backup routers in this group must
disable the option and use the IPv4 address of the router in "Associated IP address".
● Priority
Enter the priority of this virtual router. Valid values are 1-254.
If an IPv4 address is assigned to the VRRPv3 router that is also actually configured on
the local IPv4 interface, the value 255 is entered automatically. All other priorities can be
distributed freely among the VRRPv3 routers. The higher the priority, the earlier the
VRRPv3 router becomes "Master".
● Advertisement interval
Enter the interval in seconds after which a master router sends a VRRPv3 packet again.
● Preempt lower priority Master.
Allow precedence when changing roles between backup and master based on the
selection process.
● VRRP Compatible Mode
When enabled, the VRRPv3 router also sends and receives VRRPv2 frames in addition
to VRRPv3 frames for configured IPv4 addresses. Only necessary when some VRRP
routers do not support VRRPv3
Steps in configuration
To configure a virtual router as the master router, follow the steps below:
1. Select the ID of the virtual router you want to configure from the "Interface / VRID" dropdown list.
2. Select the "Status" check box.
3. Select the source address from the "Primary Address" drop-down list.
4. From the "Priority" drop-down list, enter the priority of this virtual router.
5. Select the "Master" check box.
6. Enter the interval in "Advertisement Interval".
7. Select the "Preempt lower priority Master" check box.
8. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
321
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.7.3
Addresses Overview
Overview
This page shows which IPv4 addresses the virtual router monitors. Each virtual router can
monitor a maximum of 10 IPv4 addresses.
Note
This function is available only with layer 3.
Description of the displayed values
The table has the following columns:
● Interface
Shows the Interface that functions as the virtual router.
● VRID
Shows the ID of this virtual router.
● Number of Addresses
Shows the number of IPv4 addresses.
● Associated IP Address (1) ...Associated IP Address (10)
Shows the router IPv4 addresses monitored by this virtual router. If a router takes over
the role of master, the routing function is taken over by this router for all these IPv4
addresses.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
322
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.7.4
Addresses Configuration
Creating or changing the monitored IP addresses
On this page, you can create, modify or delete the IPv4 addresses to be monitored. A
maximum of 10 IPv4 addresses can be monitored by a virtual router.
Note
This function is available only with layer 3.
Description
The page contains the following:
● Interface / VRID
Select the ID of the virtual router.
● Associated IP Address
Enter the IPv4 address that the virtual router will monitor.
A maximum of 10 IPv4 addresses are possible.
The table has the following columns:
● Select
Select the check box in the row to be deleted
● Associated IP Address
Shows the IPv4 addresses that the virtual router monitors.
Steps in configuration
1. Select the ID of the virtual router.
2. Enter the IPv4 address that the virtual router will monitor.
3. Click the "Create" button. A new entry is generated in the table.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
323
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.8
OSPFv2
5.6.8.1
Configuration
Introduction
On this page, you configure the routing using OSPFv2..
Note
This function is available only with layer 3.
Description of the displayed values
The page contains the following boxes
● OSPFv2
Enable or disable routing using OSPFv2.
● Router ID
Enter the name of one of the OSPFv2 interfaces. The name is entered in the IP address
format and does not need to match the local IP address. The router ID must be unique in
the network.
● OSPFv2-RFC1583 Compatibility
Enable the option if you still have old OSPFv2 routers in operation that are not compatible
with RFC 2328.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
324
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Border Router
Shows the status of the OSPFv2 router. If the local system is an active member in at least
2 areas, this is an area border router.
● AS Border Router
Specify whether the router is an AS border router. An AS border router intercedes
between multiple autonomous systems, for example if you have an additional RIP
network. An AS border router is also necessary to add and to distribute static routes.
● New LSA Received
Shows the number of received LSAs.
Updates and local LSAs are not counted.
● New LSA Configured
Shows the number of different LSAs sent by this local system.
● External LSA Maximum
To limit the number of entries of external LSAs in the database, enter the maximum
number of external LSAs.
● Exit Interval [s]
Enter the interval after which the OSPFv2 router once again attempts to come out of the
overflow status. A 0 means that the OSPF router attempts to exit the overflow status only
following a restart.
● Inbound Filter
Select a route map that filters inbound routes.
● Redistribute Routes (Default/Connected/Static)
Specify which known routes are distributed using OSPFv2. You can make different
decisions for the route types Default, Connected and Static.
Note
The options can only be enabled on an AS border router. Enabling the Default and Static
options, in particular, can cause problems if they are enabled at too many points in the
network, for example, forwarding loops.
● Route Map
Select a route map that filters which routes are forwarded using RIPv2.
Steps in configuration
1. Select the "OSPFv2" check box.
2. Enter the ID of the router in the "Router ID" input box.
3. Select the "AS Border Router" check box.
4. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
325
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.8.2
Areas
Overview
An autonomous system can be divided into smaller areas.
On this page, you can view, create, modify or delete the areas of the router.
Note
This function is available only with layer 3.
Description of the displayed values
The page contains the following boxes:
● Area ID
Enter the identifier of the area. The database is synchronized for all routers of an area.
The area identifier must be unique in the network.
The area identifier is a 32-bit number with the following format: x.x.x.x where x = 0 ... 255
The area identifier 0.0.0.0 is reserved for the backbone area and cannot be deleted.
This table contains the following columns:
● Select
Select the row you want to delete.
● Area ID
Shows the identifier of the area.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
326
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Area Type
Select the area type in the drop-down list.
– Standard
– Stub
– NSSA
– Backbone
● Summary
Specify whether summary LSAs are generated for this area.
– Summary: Summary LSAs are generated and sent to the area.
– No Summary: Summary LSAs are not generated and sent to the area.
● Metric
Displays the costs for the OSPFv2 interface.
● Updates
Shows the number of recalculations of the routing tables.
● LSA Count
Shows the number of LSAs in the database.
● Area BR
Shows the number of reachable area border routers (ABR) within this area.
● AS BR
Shows the number of reachable autonomous system border routers (ASBR) in this area.
Steps in configuration
1. Enter the ID for the area in the "Area ID" input box.
2. Click the "Create" button. A new entry is generated in the table.
3. Select the type of area, for example Stub in the "Area Type" drop-down list.
4. Select the "Summary LSA" entry in the "Summary" drop-down list.
5. Click the "Set Values" button.
5.6.8.3
Area Range
Creating a new OSPFv2 area range
Using the "New Entry" button in the "OSPFv2 Area Ranges" menu, up to four networks can
be grouped together under one area ID. The method is used only with area border routers.
This means that an area border router only advertises one route for grouped areas to the
outside.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
327
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Description of the displayed boxes
The page contains the following boxes:
● Area ID
Select the ID of the area from the drop-down list. You specify the ID on the "Areas" tab.
● Subnet Address
Enter the IPv4 address of the network that will be grouped.
● Subnet mask
Enter the subnet mask of the network that will be grouped.
This table contains the following columns:
● Select
Select the row you want to delete.
● Area ID
Shows the ID of the area.
● Subnet Address
Shows the IP address of the network that will be grouped.
● Subnet Mask
Shows the subnet mask of the network that will be grouped.
● Advertise
Enable this option to advertise the grouped network.
Steps in configuration
1. Select the ID of the area from the drop-down list.
2. Enter the IP address of the network that will be grouped.
3. Enter the subnet mask of the network that will be grouped.
4. Click the "Create" button. A new entry is generated in the table.
5. Enable the "Advertise" option to advertise the grouped network.
6. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
328
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.8.4
Interfaces
Overview
On this page, you can configure OSPFv2 interfaces.
Note
This function is available only with layer 3.
Description of the displayed boxes
The page contains the following boxes:
● IP Address
Select the IP address of the OSPF interface from the drop-down list.
● Area ID
Select the ID of the area that is connected to the OSPFv2 interface from the drop-down
list.
Note
For the secondary interface select the same Area ID as for the corresponding primary
interface.
The information whether an address type is primary or secondary can be found in the
"Address Type" column on the "Layer 3 (IPv4) > Subnets > Overview" page.
Select the ID of the area that is connected to the OSPFv2 interface from the drop-down list.
The table has the following columns:
● Select
Select the row you want to delete.
● IP address
Shows the IPv4 address of the OSPFv2 interface
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
329
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Area ID
Select the ID of the area that is connected to the OSPFv2 interface from the drop-down
list.
● OSPF Status
Specify whether OSPFv2 is active on the Interface.
– Enabled: OSPFv2 is enabled on the interface.
– Disabled: OSPFv2 is disabled on the interface.
● Metric
Enter the costs for the OSPFv2 interface.
● Priority
Enter the router priority. The priority is only relevant for selecting the designated router or
designated border router. This parameter can be selected differently on routers within the
same subnet.
Range of values: 0 to 255
Default setting: 1
● Trans. Delay
Enter the expected delay when sending a connection update.
Range of values: 1 s to 3600 s
Default: 1 s
● Retrans. Delay
Enter the time after which an OSPFv2 packet is transferred again if no confirmation was
received.
Range of values: 1 s to 3600 s
Default: 5 s
● Hello Interval
Enter the interval between two Hello packets.
Range of values: 1 s to 65,535 s
Default: 10 s
● Dead Interval
Enter the interval after which the neighbor router is marked as "failed" if no more Hello
packets are received from it during this time.
Default: 40 s
Steps in configuration
1. Select the IPv4 address of the OSPFv2 interface from the "IP Address" drop-down list.
2. Select the ID of the area with which the OSPFv2 interface is connected from the "Area
ID" drop-down list.
3. Click the "Create" button. A new entry is generated in the table.
4. Select the check box beside "OSPF Status".
5. In "Transit Delay", "Retrans. Delay" and "Dead Interval"enter suitable values or use the
default settings .
6. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
330
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.8.5
Interface Authentication
Configuring the interface authentication
On this page, you define the authentication of the interface.
Description of the displayed boxes
The page contains the following boxes:
● OSPF interface
Select the OSPFv2 interface for which you want to configure authentication.
● Authentication Type
Select the authentication method. You have the following options:
– None
No authentication
– Simple
Authentication using an unencrypted password
– MD5
Authentication using MD5
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
331
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Section "Simple Authentication"
● Password
Enter a password.
● Confirmation
Confirm the entered password.
Section "MD5 Authentication"
● Authentication Key ID
Enter the identifier of the MD5 authentication key.
Enter the ID for MD5 authentication with which the password will be used as a key.
Since the key ID is transferred with the protocol, the same key must be stored under the
same key ID on all neighboring routers.
The table has the following columns:
● Select
Select the row you want to delete.
● Authentication Key ID
Can only be edited if you set the MD5 authentication method. It is only possible to use
several keys there.
● MD5 Key
Enter the MD5 key.
● MD5 Key Confirmation
Confirm the entered key.
● Youngest Key ID
Shows whether or not the MD5 key is the latest key ID.
Steps in configuration
1. Select the OSPFv4 interface and the authentication method from the drop-down lists.
2. Enter the following data in the relevant input box:
– Password
– Confirmation of the password
– Identifier of the MD5 authentication key
3. Click the "Create" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
332
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.8.6
Virtual Links
Overview
Due to the protocol, each area border router must have access to the backbone area. If a
router is not connected directly to the backbone area, a virtual link to it is created.
Note
This function is available only with layer 3.
Note
Note that when creating a virtual link both the transit area and the backbone area must
already be configured.
A virtual link must be configured identically at both ends.
Description of the displayed boxes
The page contains the following note:
● Since the device is not an ABR, Virtual Links are not functional
This is displayed when at least one virtual link entry is configured and the device is not an
area border router.
The page contains the following boxes:
● Neighbor Router ID
Enter the ID of the neighbor router at the other end of the virtual connection.
● Transit Area ID
Select the ID of the area that connects both routers from the drop-down list.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
333
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
This table contains the following columns:
● Selektieren
Select the row you want to delete.
● Transit Area ID
Shows the ID via which the two routers are connected.
● Neighbor Router ID
Shows the ID of the neighbor router at the other end of the virtual connection.
● Virt. Link Status
Specify the status of the virtual link. The following states are possible:
– down: The virtual link is inactive.
– point-to-point: The virtual link is active.
● Trans. Delay
Enter the expected delay when sending a link update packet.
Range of values: 1 s to 3600 s
Default: 1 s
● Retrans. Delay
Enter the time after which a packet is transferred again if no confirmation was received.
Range of values: 1 s to 3600 s
Default: 5 s
● Hello Interval
Enter the interval between two Hello packets.
Range of values: 1 s to 65,535 s
Default: 10 s
● Dead Interval
Enter the interval after which the neighbor router counts as "failed" if no more Hello
packets are received from it during this time.
Default setting: 40 s
Steps in configuration
1. Enter the ID of the neighbor router at the other end of the virtual link in "Neighbor Router
ID".
2. Select the area ID that connects the two routers from the "Transit Area ID" drop-down list.
3. Click the "Create" button. A new entry is generated in the table.
4. Enter suitable values for "Transit Delay", "Retrans. Delay" and "Dead Interval".
5. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
334
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.8.7
Virtual Link Authentication
Configuring the interface login
On this page, you define the authentication of the interface.
Description of the displayed boxes
The page contains the following boxes:
● Virtual Link (Area/Neighbor)
Select the virtual link for which you want to configure authentication.
● Authentication Type
Select the authentication method. You have the following options:
– None
No authentication
– Simple
Authentication using an unencrypted password
– MD5
Authentication using MD5
Section "Simple Authentication"
● Password
Enter a password.
● Confirmation
Confirm the entered password.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
335
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
Section "MD5 Authentication"
● Authentication Key ID
Enter the identifier of the MD5 authentication key.
Enter the ID for MD5 authentication with which the password will be used as a key.
Since the key ID is transferred with the protocol, the same key must be stored under the
same key ID on all neighboring routers.
The table has the following columns:
● Select
Select the row you want to delete.
● Authentication Key ID
Can only be edited if you set the MD5 authentication method. It is only possible to use
several keys there.
● MD5 Key
Enter the MD5 key.
● MD5 Key Confirmation
Confirm the entered key.
● Youngest Key ID
Shows whether or not the MD5 key is the latest key ID.
Steps in configuration
Follow these steps:
1. Select the virtual connection and the authentication method from the drop-down lists.
2. Enter the following data in the relevant input box:
– Password
– Confirmation of the password
– Identifier of the MD5 authentication key
3. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
336
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.9
RIPv2
5.6.9.1
Configuration
On this page, you configure the routing using RIPv2.
Note
RIPv2 is available only on layer 3.
Settings
Figure 5-15
RIPv2 Configuration
● RIPv2
Enable or disable routing using RIPv2.
● Inbound Filter
Select a route map that filters inbound routes.
● Redistribute Routes
Specify which known routes are distributed using RIPv2.
The following types of route exist:
– Static Default
– Connected
– Static
– OSPF
● Route Map
Select a route map that filters which routes are forwarded using RIPv2.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
337
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
5.6.9.2
Interfaces
Overview
On this page, you can configure RIPv2 interfaces.
Note
RIPv2 is available only on layer 3.
Settings
Figure 5-16
RIPv2 interfaces
● IP Address
Select the IPv4 address of the RIPv2 interface.
This table contains the following columns:
● Select
Select the row you want to delete.
● IP Address
Shows the IPv4 address of the RIPv2 interface
SCALANCE XM-400/XR-500 Web Based Management (WBM)
338
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.6 The "Layer 3 (IPv4)" menu
● Send Updates
Select the way in which updates are sent:
– no send
No updates are sent.
– RIPv1
Updates for RIPv1 are sent.
– RIPv1-compat.
RIPv2 updates are sent as broadcasts according to the rules of RIPv1.
– RIPv2
Updates for RIPv2 are sent as multicasts.
– RIPv1 demand/RIPv2 demand
RIP packets are sent only as a response to an explicit query.
● Receive Updates
Select the form in which received updates are accepted:
– no receive
No updates are received.
– RIPv1
Only updates of RIPv1 are received.
– RIPv2
Only updates of RIPv2 are received.
– RIPv1/v2
Updates of RIPv1 and RIPv2 are received.
● Default Metric
Enter the costs for the RIPv2 interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
339
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7
The "Layer 3 (IPv6)" menu
5.7.1
Configuration
Introduction
The page contains the overview of the layer 3 functions for IPv6. On this page, you enable or
disable the required layer 3 function.
The functions "IPv6 Routing", "VRRPv3" and "OSPFv3" are only available with Layer 3
(IPv6).
Description
The page contains the following:
● IPv6 Routing (only available with devices with a layer 3 license)
– Enabled
IPv6 routing is enabled. If IPv4 routing is not enabled on the device this is also
enabled with this function.
– Disabled
IPv6 routing is disabled.
● VRRPv3 (only available with devices with a layer 3 license)
Enable or disable routing using VRRPv3. To use VRRPv3 , first enable the IPv6 routing
function. You can configure other settings in "Layer 3 (IPv6)> VRRPv3".
● OSPFv3 (only available with devices with a layer 3 license)
Enable or disable routing using OSPFv3. To use OSPFv3 , first enable the IPv6 routing
function. You can configure other settings in "Layer 3 (IPv6) > OSPFv3".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
340
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Steps in configuration
1. To use the required function, select the corresponding check box.
2. Click the "Set Values" button.
5.7.2
Subnets
Connected Subnets
On this page, you can enable IPv6 on the interface. The interface is also called an IPv6
interface. An IPv6 interface can have several IPv6 addresses.
Description
The page contains the following:
● Interface
Select the IP interface on which IPv6 will be enabled.
● IPv6 Enable
Enable or disable IPv6 on the interface.
Note
Disabling IPv6
As soon as IPv6 is enabled on the IP interface, IPv6 can only be disabled by removing
the interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
341
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● IPv6 Address
Enter the IPv6 address. The entry depends on the selected address type.
● Prefix Length
Enter the number of left-hand bits belonging to the prefix
● IPv6 Address Type
Select the address type.
– Unicast
– Anycast
– Link Local IPv6 address is only valid on the link
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Interface Name
Shows the name of the interface.
● IPv6 Address
Shows the IP address of the subnet.
● Prefix Length
Shows the prefix length.
● IPv6 Address Type
Displays the address type. The following values are possible:
– Unicast
– Anycast
– Link Local
Steps in configuration
Forming a link local address automatically
1. Select the required interface.
2. Enable IPv6.
3. Click the "Create" button. In the table an entry with the interface is created and the
automatically formed IPv6 address is displayed.
Assigning link local address
1. Select the required interface.
2. Enable IPv6.
3. In "IPv6 Address" enter the link local address, e.g. FE80::21B:1BFF:FE40:9155
4. Enter "128" in "Prefix Length".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
342
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5. For "IPv6 Address Type" select the entry "Link Local".
6. Click the "Create" button. In the table an entry with the interface is created and the IPv6
address is displayed.
5.7.3
DHCPv6 client
5.7.3.1
DHCPv6 client
On this page, you specify whether the DHCPv6 client receives not only the configuration
settings but also the IPv6 address or supports the "prefix delegation" function.
Prefix delegation
The DHCPv6 server delegates the distribution of the IPv6 prefix to the DHCPv6 client. To do
this an IPv6 interface must be configured on the DHCPv6 client as a PD client. Via the PD
client, the DHCPv6 client obtains an IPv6 prefix from the DHCPv6 server and stores it under
a prefix name. The IPv6 interfaces of the DHCPv6 client the should adopt the prefix are
configured as so-called PD sub-clients.
You configure the PD sub-clients in "Layer 3 (IPv6)" > "DHCPv6 Client" > "DHCPv6 PD Sub
Client".
Description
The page contains the following:
● Interface
Select the IP interface via which the DHCPv6 client functions.
● Enable
Enable or disable the DHCPv6 client for the relevant interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
343
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Mode
Specify the procedure.
– Status dependent Obtains the IPv6 address and the configuration file from the
DHCPv6 server
– Stateless: Obtains only the configuration file from the DHCPv6 server
– Prefix Delegation: The DHCPv6 client takes over the distribution of the IPv6 prefix
● Prefix Name
Enter the prefix name that will be further distributed by the DHCPv6 router. Can only be
edited with the "Prefix Delegation" procedure. The DHCPv6 router stores IPv6 prefix of
the DHCPv6 server under this name.
● Rapid Commit
When enabled the procedure for the IPv6 address assignment is shortened. Instead of 4
DHCPv6 messages (SOLICIT, ADVERTISE , REQUEST, REPLY) only 2 DHCPv6
messages (SOLICIT, REPLY) are used. You will find further information on the messages
in RFC 3315.
Steps in configuration
1. Select the interface
2. Enable the DHCPv6 client.
3. Select the mode.
4. Enter a name for the prefix. Only necessary if "Prefix Delegation" is set as the mode.
5. Click the "Create" button.
6. Click the "Set Values" button.
5.7.3.2
DHCPv6 PD Sub Client
On this page you specify which IPv6 interfaces of the DHCPv6 client will adopt the prefix.
This achieved by assigning the prefix name followed by a prefix and the required prefix
length to them as the IP address. Here, the first bits of the configured prefix are replaced by
the values stored in the prefix name.
Example:
Under the prefix name "test", the following IPv6 prefix is stored: 2001:DB8:1234::/48
Prefix = 2002:AF9:5678::1
Prefix length = 64
This results in the following IPv6 address 2001:DB8:1234::1
SCALANCE XM-400/XR-500 Web Based Management (WBM)
344
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following:
● Interface
Select the interface that functions as the PD sub client. Only IP interfaces can be
selected
● Prefix Name
Enter the prefix name that will be further distributed by the PD router. The PD router
stores IPv6 prefix of the DHCPv6 server under this name.
● Prefix
Specify the network identifier of the host.
● Prefix Length
Enter the number of left-hand bits belonging to the prefix
This table contains the following columns
● Select
Select the check box in the row to be deleted
● Interface Name
Shows the name of the interface
● Prefix Name
Shows the name of the prefix.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
345
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Prefix
Shows the prefix.
● Prefix Length
Shows the prefix length.
● Generated Addresses
Shows the IPv6 address formed from the prefix name, prefix and prefix length.
5.7.4
Static Routes
On this page, you configure static IPv6 routes.
Description
The page contains the following:
● Destination Network
Enter the network address of the destination that can be reached via this route.
● Prefix Length
Enter the number of left-hand bits belonging to the prefix
● Gateway
Enter the IPv4 address of the gateway via which this network address is reachable.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
346
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Metric
Enter the metric for the route. The metric corresponds to the quality of a connection,
based for example on speed or costs. If there are several equal routes, the route with the
lowest metric value is used.
Range of values: 1 - 254
● Interface
Specify the interface via which the network address of the destination is reached.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Destination Network
Shows the network address of the destination.
● Prefix Length
Shows the prefix length.
● Gateway
Shows the IPv6 address of the next gateway.
● Interface
Shows the Interface of the route.
● Metric
Enter the metric for the route. When creating the route, "not used" is entered
automatically. The metric corresponds to the quality of a connection, based for example
on speed or costs. If there are several equal routes, the route with the lowest metric value
is used.
Range of values: 1 - 254
● Status
Shows whether or not the route is active.
Steps in configuration
1. Enter the network address of the destination.
2. Enter the prefix length.
3. Enter the IPv6 address of the gateway.
4. Select the required interface.
5. Enter the metric of the route.
6. Click the "Create" button. A new entry is generated in the table.
7. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
347
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.5
Route maps
5.7.5.1
General
Route maps
With route maps, you control how routing information is further processed. You can filter
routing information and specify whether the information is further processed, modified or
discarded.
Route maps operate according to the following principle:
● Routing information is compared with the filters of the route maps.
● The comparison is continued until the filters of a route map match the properties of an
item of information.
● The information is then processed according to the route map settings:
– The routing information is discarded.
– The properties of the routing information are changed.
Settings
Figure 5-17
Route maps general
● Name
Enter the name for the route map.
● Sequence Number
Enter a number for the route map.
You can create several route maps with the same name but with different sequence
numbers. The sequence numbers then specify the order in which the route maps are
processed.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
348
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
The table has the following columns:
● Select
Select the row you want to delete.
● Name
Shows the name of the route map.
● Sequence Number
Shows the sequence number of the route map.
● Action
Specify what happens to the routing information that matches the settings of the route
map:
– permit
The routing information is further processed according to the settings you make in the
"Set" tab.
– deny
The routing information is discarded.
5.7.5.2
Interface & Value Match
On this page, you specify whether or not the routing information for a route map is filtered
according to interfaces, metric or tags.
Settings
Figure 5-18
Filtering route maps and metric
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
349
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Route Map (Name/Seq. No.)
Select a route map.
The created route maps are available to you.
● Type
Select the basis for the filtering:
– Interface
– Metric
– Tag
● Interface
Select an interface.
This box is active only if you have selected the "Interface" entry in the "Type" drop-down
list.
● Metric
Enter a value for the metric.
This box is active only if you have selected the "Metric" entry in the "Type" drop-down list.
● Tag
Enter a value for the tag.
This box is active only if you have selected the entry "Tag in the "Type" drop-down list.
The table has the following columns:
● Select
Select the row you want to delete.
● Type
Shows the selected type:
– Interface
– Metric
– Tag
● Value
Shows the selected interface or the value of the metric or of the tag.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
350
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.5.3
Destination Match
On this page, you specify whether or not the routing information for a route map is filtered
based on the destination IP address.
Settings
● Route Map (Name/Seq. No.)
Select a route map.
● IP Address
Enter the IPv6 address of the destination on which the filtering is based.
● Prefix Length
Enter the number of left-hand bits belonging to the prefix
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● IP Address
Shows the IPv6 address of the destination.
● Prefix Length
Shows the prefix length.
5.7.5.4
Next-Hop match
On this page, you specify whether or not the filtering for a route map will be based on the
router to which the routing information is sent next.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
351
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Settings
Figure 5-19
Route Maps Next Hop Match
● Route Map (Name/Seq. No.)
Select a route map.
● IP Address
Enter the IP address of the router to which the routing information will be sent next.
The table has the following columns:
● Select
Select the row you want to delete.
● IP Address
Shows the IP address of the next router.
5.7.5.5
Set
On this page, you specify whether or not the routing information will be changed by a route
map.
You can only change the information of a "Permit" route map.
If, for example, you have filtered based on a certain metric, you can change the value of the
metric here. The routing information is then forwarded with the new value.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
352
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Settings
Figure 5-20
Route maps set
● Route Map (Name/Seq. No.)
Select a route map.
The table has the following columns:
● Select
Select the row you want to delete.
● Name
Shows the name of the route map.
● Sequence Number
Shows the sequence number of the route map.
● Metric
Enter the new value for the metric with which the routing information will be forwarded.
● Tag
Enter the new value for the tag with which the routing information will be forwarded.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
353
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.6
DHCPv4 Relay Agent
5.7.6.1
Interfaces
A DHCPv6 relay agent forwards the DHCP queries of the DHCPv6 client to the DHCPv6
server. When forwarding the remote ID is inserted in the DHCP query. The remote ID is the
identifier of the interface. With this, the DHCPv6 relay agent can send the reply of the
DHCPv6 server to the required DHCPv6 client.
Description
The page contains the following:
● Remote ID (Opt. 37)
When enabled the DHCP relay agent option 37 (Remote ID) is used. Specify the type of
identifier in "Remote ID Type".
● Interface
Select the IPv6 interface.
The table has the following columns:
● Select
Select the row you want to delete.
● Interface
Interface to which the settings relate.
● Current Remote ID
Shows which remote ID is currently being used.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
354
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Remote ID Type
Select hat is used as the identifier for the IPv6 interface. The following options are
available:
– DUID
DHCP Unique Identifier
– System Name
System name of the device
– Management IP
Management IPv6 address of the device
– User Defined
User-defined entry
● DHCP Unique Identifier
Enter the DUID (DHCP Unique Identifier).
● User Defined
Enter a user-defined entry as the identifier.
Steps in configuration
1. Enable Remote ID (Opt. 37).
2. Select the required interface and click the "Set Values" button.
3. Click the "Create" button. A new entry is generated in the table.
4. Specify the type of remote ID in "Remote ID Type" e.g. the system name. The system
name of the device is used as the identifier.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
355
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.6.2
Server Addresses
On this page you enable the DHCPv6 relay agent on the interface. You also specify which
DHCPv6 server can be reached via it.
Description
The page contains the following:
● Relay Interface
Select the interface on which the DHCPv6 relay agent accepts DHCPv6 requests.
● Server IP Address
Enter the IPv6 address of the DHCPv6 server to which the DHCPv6 requests will be
forwarded. The address can be either the unicast or the link local multicast address. With
the link local multicast address you need to specify an interface, via which the DHCPv6
server can be reached. You configure the interface in "Layer 3 (IPv6) > DHCPv6 Relay
Agent > Outgoing Interfaces".
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Server IP Address
Shows the IP64 address of the DHCPv6 server.
Steps in configuration
1. Select the required interface
2. Enter the IPv6 address of the DHCPv6 server.
3. Click the "Create" button. A new entry is generated in the table.
4. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
356
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.6.3
Outgoing Interfaces
Outgoing Interfaces
The link local multicast address (ff02::1:2 ) of the DHCPv6 server can only be reached by
devices located on the same link. On this page, you specify the interface via which this
DHCPv6 server can be reached.
Description
The page contains the following:
● Relay Interface
Select the IPv6 interface on which the DHCPv6 relay agent accepts DHCPv6 requests.
● Server IP Address
Select the IPv6 address of the DHCPv6 server.
● Outgoing Interface
Select the IPv6 interface via which the DHCPv6 server can be reached.
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Server IP Address
Shows the IPv6 address of the DHCPv6 server.
● Outgoing Interface
Shows the IPv6 interface via which the DHCPv6 server can be reached.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
357
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.7
VRRPv3
5.7.7.1
Routers
Introduction
Using the "Create" button, you can create new virtual routers. A maximum of 52 Virtual
routers can be configured. You can configure other parameters on the "Configuration" tab.
Note
• This function is available only with layer 3.
• Simultaneous operation of VRRP and VRRPv3 is not possible.
• Select the "VRRPv3" check box to configure VRRPv3.
• You can use VRRPv3 on VLAN interfaces. Router ports are not supported.
Description
The page contains the following:
● VRRPv3
Enable or disable routing using VRRPv3. Can only be enabled when "Layer 3 (IPv6) >
Configuration" "IPv6 Routing" is enabled.
● Reply to pings on virtual interfaces
When enabled, the virtual IPv6 addresses also reply to the ping.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
358
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Interface
Select the required VLAN interface operating as virtual router.
● VRID
Enter the ID of the virtual router. This ID defines the group of routers that form a virtual
router (VR). In the group, this is the same. It can no longer be used for other groups.
Valid values are 1.. 255.
The table has the following columns:
● Select
Select the check box in the row to be deleted.
● Interface
Shows the Interface that functions as the virtual router.
● VRID
Shows the ID of the virtual router.
● Virtual MAC Address
Shows the virtual MAC address of the virtual router.
● Primary IP Address
Shows the numerically lowest IPv6 address in this VLAN. The entry "::" means that the
"Primary" address on this VLAN is used. Otherwise all IPv6 addresses configured on this
VLAN in the "Layer 3 (IPv6) > Subnets" menu are valid addresses.
● Router State
Shows the current status of the virtual router. Possible values are:
– Master
The router is the master router and handles the routing functionality for all assigned
IPv4 addresses.
– Backup
The router is the backup router. If the master router fails, the backup router takes over
the tasks of the master router.
– Initialize
The virtual router has just been turned on. It will soon change to the "Master" or
"Backup" state.
● Master IP Address
Shows the IPv6 address of the master router.
● Priority
Shows the priority of the virtual router.
Valid values are 1-254.
The current master router is automatically given 255. All other priorities can be distributed
freely among the VRRPv3 routers. The higher the priority, the earlier the VRRPv3 router
becomes "Master".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
359
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Advert. Internal
Shows the interval at which the master router sends VRRPv3 packets.
● Preempt
Shows the precedence of a router when changing roles between backup and master.
– yes
This router has precedence when changing roles.
– no
This router does not have precedence when changing roles.
Steps in configuration
1. Enable "VRRPv3".
2. Select the required interface.
3. Enter the ID of the virtual router in "VRID".
4. Select the "Reply to pings on virtual interfaces" option so that virtual IPv6 addresses reply
to pings as well.
5. Click the "Create" button. A new row is inserted in the table.
6. Click the "Set Values" button. To configure the virtual router, click on the "Configuration"
tab.
5.7.7.2
Configuration
Introduction
On this page, you configure the virtual router.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
360
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following:
● Interface / VRID
Select the ID of the virtual router to be configured.
● Primary Address
Select the primary IPv6 address. If the router becomes master router, the router uses this
IPv4 address.
Note
If you only configure one subnet on this VLAN, no entry is necessary. The entry is then ::.
If you configure more than one subnet on the VLAN and you want a specific IPv6 address
to be used as the source address for VRRP packets, select the IPv6 address. Otherwise,
the IPv6 address with priority will be used.
● Master
If enabled, the primary IPv6 address is entered for "Associated IP Address". This means
that the highest priority IPv6 address of the VRRP router is used as the virtual IP address
of the virtual master router. The backup routers in this group must disable the option and
use the IPv6 address of the router in "Associated IP address".
● Priority
Enter the priority of this virtual router. Valid values are 1-254.
The current master router is always given 255. All other priorities can be distributed freely
among the redundant routers. The higher the priority, the earlier the router becomes
"Master".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
361
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Advertisement interval
Enter the interval in seconds after which a master router sends a VRRPv3 packet again.
● Preempt lower priority Master.
Allow precedence when changing roles between backup and master based on the
selection process.
Steps in configuration
To configure a virtual router as the master router, follow the steps below:
1. Select the ID of the virtual router you want to configure from the "Interface / VRID" dropdown list.
2. Select the "Status" check box.
3. Select the source address from the "Primary Address" drop-down list.
4. From the "Priority" drop-down list, enter the priority of this virtual router.
5. Select the "Master" check box.
6. Enter the interval in "Advertisement Interval".
7. Select the "Preempt lower priority Master" check box.
8. Click the "Set Values" button.
5.7.7.3
Addresses Overview
Overview
This page shows which IPv6 addresses the virtual router monitors. Each virtual router can
monitor a maximum of 10 IPv6 addresses.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
362
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description of the displayed values
The table has the following columns:
● Interface
Shows the Interface that functions as the virtual router.
● VRID
Shows the ID of this virtual router.
● Number of Addresses
Shows the number of IPv6 addresses.
● Associated IP Address (1) ...Associated IP Address (10)
Shows the router IPv6 addresses monitored by this virtual router. If a router takes over
the role of master, the routing function is taken over by this router for all these IPv6
addresses.
5.7.7.4
Addresses Configuration
Creating or changing the monitored IP addresses
On this page, you can create, modify or delete the IPv4 addresses to be monitored. A
maximum of 10 IPv4 addresses can be monitored by a virtual router.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
363
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following:
● Interface / VRID
Select the ID of the virtual router.
● Associated IP Address
Enter the IPv6 address that the virtual router will monitor.
A maximum of 10 IPv6 addresses are possible.
The table has the following columns:
● Select
Select the check box in the row to be deleted
● Associated IP Address
Shows the IPv6 addresses that the virtual router monitors.
Steps in configuration
1. Select the ID of the virtual router.
2. Enter the IPv6 address that the virtual router will monitor.
3. Click the "Create" button. A new entry is generated in the table.
5.7.8
OSPFv3
5.7.8.1
Configuration
Introduction
On this page, you configure the routing using OSPFv3.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
364
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following boxes:
● OSPFv3
Enable or disable routing using OSPFv3.
● Router ID
Enter the designation of the OSPFv3 interfaces. The router ID is specified in IPv4 format
and must be unique in the network.
● Border Router
Displays the status of the OSPFv3 router. If the local system is an active member in at
least 2 areas, this is an area border router.
● AS Border Router
Specify whether the router is an AS border router. An AS border router intercedes
between multiple autonomous systems, for example if you have an additional RIP
network. An AS border router is also necessary to add and to distribute static routes.
● New LSA Received
Shows the number of received LSAs. Updates and its own LSAs are not counted.
● New LSA Configured
Shows the number of different LSAs sent by this local system.
● External LSA Maximum
To limit the number of entries of external LSAs in the database, enter the maximum
number of external LSAs.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
365
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Exit Interval [s]
Enter the interval after which the OSPFv3 router once again attempts to come out of the
overflow status. A 0 means that the OSPFv3 router attempts to exit the overflow status
only following a restart.
● Inbound Filter
Select a route map that filters inbound routes.
● Redistribute Routes
Specify which known routes are distributed using OSPFv3. You make different decisions
for the route types Connected, Static and RIPng.
Note
The options can only be enabled on an AS border router. Enabling the Default and Static
options, in particular, can cause problems if they are enabled at too many points in the
network, for example, forwarding loops.
● Route Map
Select a route map that filters which routes are forwarded using RIPng.
Steps in configuration
1. Select the "OSPFv3" check box.
2. Enter the ID of the router in the "Router ID" input box.
3. Select the "AS Border Router" check box.
4. Click the "Set Values" button.
5.7.8.2
Areas
Overview
An autonomous system can be divided into smaller areas.
On this page, you can view, create, modify or delete the areas of the router.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
366
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following:
● Area ID
Enter the designation of the area. The database is synchronized for all routers of an area.
The area identifier must be unique in the network.
The area identifier is a 32-bit number with the following format: x.x.x.x where x = 0 ... 255
The area identifier 0.0.0.0 is reserved for the backbone area and cannot be deleted.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Area ID
Shows the designation of the area.
● Area Type
Specify the type of area.
– Standard
– Stub
– NSSA
– Backbone
● Summary
Specify whether summary LSAs are generated for this area.
– Summary: Summary LSAs are generated and sent to the area.
– No Summary: Summary LSAs are not generated and sent to the area.
● Metric
Displays the costs for the OSPFv3 interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
367
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Updates
Shows the number of recalculations of the routing tables.
● LSA Count
Shows the number of LSAs in the database.
● Area BR
Shows the number of reachable area border routers (ABR) within this area.
● AS BR
Shows the number of reachable autonomous system border routers (ASBR) in this area.
Steps in configuration
1. Enter the ID for the area in the "Area ID" input box.
2. Click the "Create" button. A new entry is generated in the table.
3. Select the type of area, for example Stub in the "Area Type" drop-down list.
4. Select the "Summary LSA" entry in the "Summary" drop-down list.
5. Click the "Set Values" button.
5.7.8.3
Area
Creating a new OSPFv3 area range .
On this page, you can group up to 4 networks under one area ID. The method is used only
with area border routers. This means that an area border router only advertises one route for
grouped areas to the outside.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
368
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following boxes:
● Area ID
Select the area ID of the area. You specify the ID on the "Areas" tab.
● Prefix
Enter the IPv6 address of the network that will be grouped.
● Prefix Length
Enter the number of bits belonging to the prefix that will be grouped.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Area ID
Shows the ID of the area.
● Prefix
Shows the IPv6 address of the network that will be grouped.
● Prefix Length
Enter the number of bits that will belong to the prefix.
● Advertise
Enable this option to advertise the grouped network.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
369
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Steps in configuration
1. Select the area ID of the area.
2. Enter the prefix of the network that will be grouped.
3. Enter the prefix length of the network that will be grouped.
4. Click the "Create" button. A new entry is generated in the table.
5. Enable the "Advertise" option to advertise the grouped network.
6. Click the "Set Values" button.
5.7.8.4
Interfaces
Overview
On this page, you can configure OSPFv3 interfaces.
Note
This function is available only with layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
370
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following:
● Interface
Select the IPv6 interface on which OSPFv3 will be enabled.
● Area ID
Select the area ID of the area with which the OSPFv3 interface is connected.
Note
For the secondary interface select the same Area ID as for the corresponding primary
interface.
The information whether a primary or secondary interface is involved can be found in
"Layer 3 (IPv6) > Subnets".
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Interface
Shows the OSPFv3 interface.
● Area ID
Select the area ID of the area with which the OSPFv3 interface is connected.
● OSPF Status
Specify whether or not OSPFv3 is active on the interface.
– Enabled: OSPFv3 is enabled on the interface.
– Disabled: OSPFv3 is disabled on the interface.
● Metric
Enter the costs for the OSPFv3 interface.
● Priority
Enter the router priority. The priority is only relevant for selecting the designated router or
designated border router. This parameter can be selected differently on routers within the
same subnet.
Range of values: 0 to 255
Default: 1.
● Trans. Delay
Enter the required delay when sending a connection update.
Range of values: 1 s to 3600 s
Default: 1 s
● Retrans. Interval
Enter the time after which an OSPFv3 packet is transferred again if no confirmation was
received.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
371
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Range of values: 1 s to 3600 s
Default: 5 s
● Hello Interval
Enter the interval between two Hello packets.
Range of values: 1 s to 65,535 s
Default: 10 s
● Dead Interval
Enter the interval after which the neighbor router is marked as "failed" if no more Hello
packets are received from it during this time.
Default: 40 s
Steps in configuration
1. Select the required interface. The interface is configured as an OSPFv3 Interface
2. Select the area ID of the area with which the OSPFv3 interface is connected.
3. Click the "Create" button. A new entry is generated in the table.
4. Select the check box under "OSPF Status".
5. Enter suitable values or use the default settings for "Trans. Delay", "Retrans. Interval" and
"Dead Interval".
6. Click the "Set Values" button.
5.7.8.5
Virtual Links
Overview
Due to the protocol, each area border router must have access to the backbone area. If a
router is not connected directly to the backbone area, a virtual link to it is created.
Note
This function is available only with layer 3.
Note
Note that when creating a virtual link both the transit area and the backbone area must
already be configured.
A virtual link must be configured identically at both ends.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
372
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Description
The page contains the following:
● Neighbor Router ID
Enter the ID of the neighbor router at the other end of the virtual connection.
● Transit Area ID
● Select the ID of the area that connects the two routers.
This table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Transit Area ID
Shows the ID via which the two routers are connected.
● Neighbor Router ID
Shows the ID of the neighbor router at the other end of the virtual connection.
● Virt. Link Status
Specify the status of the virtual link. The following states are possible:
– down: The virtual link is inactive.
– point-to-point: The virtual link is active.
● Trans. Delay
Enter the required delay when sending a connection update.
Range of values: 1 s to 3600 s
Default: 1 s
● Retrans. Interval
Enter the time after which a packet is transferred again if no confirmation was received.
Range of values: 1 s to 3600 s
Default: 5 s
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
373
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
● Hello Interval
Enter the interval between two Hello packets.
Range of values: 1 s to 65,535 s
Default: 10 s
● Dead Interval
Enter the interval after which the neighbor router counts as "failed" if no more Hello
packets are received from it during this time.
Default setting: 40 s
Steps in configuration
1. Enter the ID of the neighbor router at the other end of the virtual link.
2. Select the area ID that connects the two routers.
3. Click the "Create" button. A new entry is generated in the table.
4. Enter suitable values in "Trans. Delay", Retrans. Interval" and "Dead Interval".
5. Click the "Set Values" button.
5.7.9
RIPng
5.7.9.1
RIPng Configuration
On this page, you configure routing with RIPng.
Note
RIPng is available only on layer 3.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
374
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
Settings
● Inbound Filter
Select a route map that filters inbound routes.
● Redistribute Routes
Specify which known routes are distributed using RIPv2.
The following types of route exist:
– Connected
– Static
– OSPFv3
● Route Map
Select a route map that filters which routes are forwarded using RIPng.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
375
Configuring with Web Based Management
5.7 The "Layer 3 (IPv6)" menu
5.7.9.2
RIPng interfaces
Overview
On this page, you specify the interfaces that support RIPng.
Figure 5-21
RIPv2 Interfaces
Note
RIPng is available only on layer 3.
Description
This table contains the following columns:
● Interface
Shows the available IPv6 interface.
● Admin State
Enable or disable the RIPng routing for the interface.
● Default Metric
Enter the costs for the RIPng interface.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
376
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
5.8
The "Security" menu
5.8.1
User management
Overview of user management
Access to the device is managed by configurable user settings. Set up users with a
password for authentication. Assign a role with suitable rights to the users.
The authentication of users can either be performed locally by the device or by an external
RADIUS server. You configure how the authentication is handled on the "Security > AAA >
General" page.
Compatibility with predecessor versions
With firmware version 5.1, user management was expanded by the RADIUS authorization
mode "SiemensVSA". To ensure compatibility with firmware versions ≤ 5.0, the default
setting was selected so that following a firmware update the earlier authentication mode
"conventional" continues to be used.
Local logon
The local logging on of users by the device runs as follows:
1. The user logs on with user name and password on the device.
2. The device checks whether an entry exists for the user.
→ If an entry exists, the user is logged in with the rights of the associated role.
→ If no corresponding entry exists, the user is denied access.
Login via an external RADIUS server
RADIUS (Remote Authentication Dial-In User Service) is a protocol for authenticating and
authorizing users by servers on which user data can be stored centrally.
Depending on the RADIUS authorization mode you have selected on the "Security > AAA >
RADIUS Client" page, the device evaluates different information of the RADIUS server.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
377
Configuring with Web Based Management
5.8 The "Security" menu
RADIUS authorization mode "Standard"
If you have set the authorization mode "conventional", the authentication of users via a
RADIUS server runs as follows:
1. The user logs on with user name and password on the device.
2. The device sends an authentication request with the login data to the RADIUS server.
3. The RADIUS server runs a check and signals the result back to the device.
– The RADIUS server reports a successful authentication and returns the value
"Administrative User" to the device for the attribute "Service Type".
→ The user is logged in with administrator rights.
– The RADIUS server reports a successful authentication and returns a different or even
no value to the device for the attribute "Service Type".
→ The user is logged in with read rights.
– The RADIUS server reports a failed authentication to the device:
→ The user is denied access.
RADIUS authorization mode "SiemensVSA"
Requirement
For the RADIUS authorization mode "Siemens VSA" the following needs to be set on the
RADIUS server:
● Manufacturer code: 4196
● Attribute number: 1
● Attribute format: Character string (group name)
Procedure
SCALANCE XM-400/XR-500 Web Based Management (WBM)
378
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
If you have set the authorization mode "SiemensVSA", the authentication of users via a
RADIUS server runs as follows:
1. The user logs on with user name and password on the device.
2. The device sends an authentication request with the login data to the RADIUS server.
3. The RADIUS server runs a check and signals the result back to the device.
Case A: The RADIUS server reports a successful authentication and returns the group
assigned to the user to the device.
– The group is known on the device and the user is not entered in the table "External
User Accounts"
→ The user is logged in with the rights of the assigned group.
– The group is known on the device and the user is entered in the table "External User
Accounts"
→ The user is assigned the role with the higher rights and logged in with these rights.
– The group is not known on the device and the user is entered in the table "External
User Accounts"
→ The user is logged in with the rights of the role linked to the user account.
– The group is not known on the device and the user is not entered in the table "External
User Accounts"
→ The user is logged in with the rights of the role "Default".
Case B: The RADIUS server reports a successful authentication but does not return a
group to the device.
– The user is entered in the table "External User Accounts":
→ The user is logged in with the rights of the linked role "".
– The user is not entered in the table "External User Accounts":
→ The user is logged in with the rights of the role "Default".
Case C: The RADIUS server reports a failed authentication to the device:
– The user is denied access.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
379
Configuring with Web Based Management
5.8 The "Security" menu
5.8.2
Users
5.8.2.1
Roles
Roles
On this page, you create roles that are valid locally on the device.
Note
The values displayed depend on the rights of the logged-in user.
Note
You can create up to 28 additional roles.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
380
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
Description
The page contains the following:
● Role Name
Enter the name for the role. The name must meet the following conditions:
– It must be unique.
– It must be between 1 and 64 characters long.
Note
Role name cannot be changed
After creating a role, the name of the role can no longer be changed.
If a name of a role needs to be changed, the role must be deleted and a new role
created.
The table contains the following columns:
● Select
Select the check box in the row to be deleted.
Note
Predefined roles and assigned roles cannot be deleted or modified.
● Role
Shows the name of the role.
● Function Right
Select the function rights of the role.
– 1
Users with this role can read device parameters but cannot change them.
– 15
Users with this role can both read and change device parameters.
Note
Function right cannot be changed
If you have assigned a role, you can no longer change the function right of the role.
If you want to change the function right of a role, follow the steps outlined below:
1. Delete all assigned users.
2. Change the function right of the role:
3. Assign the role again.
● Description
Enter a description for the role. With predefined roles a description is displayed. The
description text can be up to 100 characters long.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
381
Configuring with Web Based Management
5.8 The "Security" menu
Procedure
Creating a role
1. Enter the name for the role.
2. Click the "Create" button.
3. Select the function rights of the role.
4. Enter a description of the role.
5. Click the "Set Values" button.
Deleting a role
1. Select the check box in the row to be deleted.
2. Click the "Delete" button. The entries are deleted and the page is updated.
5.8.2.2
Groups
User Groups
On this page you link a group with a role.
In this example the group "Administrators" is linked to the "admin"role: The group is defined
on a RADIUS server. The role is defined locally on the device. When a RADIUS server
authenticates a user and assigns the user to the "Administrators" group, this user is given
rights of the "admin" role.
Note
The values displayed depend on the rights of the logged-in user.
Note
You can create up to 32 groups.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
382
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
Description
The page contains the following:
● Group Name
Enter the name of the group. The name must match the group on the RADIUS server.
The name must meet the following conditions:
– It must be unique.
– It must be between 1 and 64 characters long.
The table contains the following columns:
● Select
Select the check box in the row to be deleted.
● Group
Shows the name of the group.
● Role
Select a role. Users who are authenticated with the linked group on the RADIUS server
receive the rights of this role locally on the device.
You can choose between system-defined and self-defined roles, refer to the page
"Security > Users > Roles.".
● Description
Enter a description for the link of the group.to a role. The description text can be up to
100 characters long.
Procedure
Linking a group to a role.
1. Enter the name of a group.
2. Click the "Create" button.
3. Select a role.
4. Enter a description for the link of a group.to a role.
5. Click the "Set Values" button.
Deleting the link between a group and a role
1. Select the check box in the row to be deleted.
2. Click the "Delete" button. The entries are deleted and the page is updated.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
383
Configuring with Web Based Management
5.8 The "Security" menu
5.8.2.3
Local Users
Local users
On this page, you create local users with the corresponding rights.
When you create or delete a local user this change is also made automatically in the table
"External User Accounts". If you want to make change explicitly for the internal or external
user table, use the CLI commands.
Note
The values displayed depend on the rights of the logged-in user.
Note
You can create up to 16 additional users.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
384
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
Description
The page contains the following:
● User Account
Enter the name for the user. The name must meet the following conditions:
– It must be unique.
– It must be between 1 and 250 characters long.
Note
User name cannot be changed
After creating a user, the user name can no longer be modified.
If a user name needs to be changed, the user must be deleted and a new user created.
● Password Policy
Shows which password policy is being used.
● Password
Enter the password for the user.
Note
Password Policy: high
Note the following password policies:
• Password length: at least 8 characters, maximum 128 characters
• At least 1 uppercase letter
• At least 1 special character
• At least 1 number
● Password Confirmation
Enter the password again to confirm it.
● Role
Select a role.
You can choose between system-defined and self-defined roles, refer to the page
"Security > Users > Roles.".
The table contains the following columns:
● Select
Select the check box in the row to be deleted.
Note
The preset users as well as logged in users cannot be deleted or changed.
● User Account
Shows the user name.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
385
Configuring with Web Based Management
5.8 The "Security" menu
● Role
Shows the role of the user.
● Description
Displays a description of the user account. The description text can be up to 100
characters long.
Procedure
Creating users
1. Enter the name for the user.
2. Enter the password for the user.
3. Enter the password again to confirm it.
4. Select the role of the user.
5. Click the "Create" button.
6. Enter a description of the user.
7. Click the "Set Values" button.
Deleting users
1. Select the check box in the row to be deleted.
2. Click the "Delete" button. The entries are deleted and the page is updated.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
386
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
5.8.3
Passwords
Configuration of the device passwords
Note
If you are logged in via a RADIUS server, you cannot change any passwords.
On this page, you can change passwords. If you are logged in with the right to change
device parameters, you can change the passwords for all user accounts. If you are logged in
with read rights, you can only change your own password.
Description of the displayed boxes
● Current User
Shows the user that is currently logged in.
● Current User Password
Enter the password for the currently logged in user.
● User Account
Select the user whose password you want to change.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
387
Configuring with Web Based Management
5.8 The "Security" menu
● New Password
Enter the new password for the selected user.
Note
Password Policy: high
Note the following password policies:
• Password length: at least 8 characters, maximum 128 characters
• at least 1 uppercase letter
• at least 1 special character
• at least 1 number
● Password Confirmation
Enter the new password again to confirm it.
Procedure
Note
The factory settings for the passwords when the devices ship are as follows:
• admin: admin
• user: user
When you log in for the first time or following a "Restore Factory Defaults and Restart", with
the preset user "admin" you will be prompted to change the password.
Note
Changing the password in Trial mode
Even if you change the password in Trial mode, this change is saved immediately.
1. Enter the password for the currently logged in user in the "Current User Password" input
box.
2. In the "User Account" drop-down list select the user whose password you want to
change.
3. Enter the new password for the selected user in the "New Password" input box.
4. Repeat the new password in the "Password Confirmation" input box.
5. Click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
388
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
5.8.4
AAA
5.8.4.1
General
Login of network nodes
The designation "AAA" stands for "Authentication, Authorization, Accounting". This feature is
used to identify and allow network nodes, to make the corresponding services available to
them and to specify the range of use.
On this page, you configure the login.
Description of the displayed boxes
The page contains the following boxes:
Note
To be able to use the login authentication "RADIUS", "Local and RADIUS" or "RADIUS and
fallback Local" a RADIUS server must be stored and configured for user authentication.
● Login Authentication
Specify how the login is made:
– Local
The authentication must be made locally on the device.
– RADIUS
The authentication must be handled via a RADIUS server.
– Local and RADIUS
The authentication is possible both with the users that exist on the device (user name
and password) and via a RADIUS server.
The user is first searched for in the local database. If the user does not exist there, a
RADIUS request is sent.
– RADIUS and fallback local
The authentication must be handled via a RADIUS server.
A local authentication is performed only when the RADIUS server cannot be reached
in the network.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
389
Configuring with Web Based Management
5.8 The "Security" menu
5.8.4.2
RADIUS Client
Authentication over an external server
The concept of RADIUS is based on an external authentication server.
Each row of the table contains access data for one server. In the search order, the primary
server is queried first. If the primary server cannot be reached, secondary servers are
queried in the order in which they are entered.
If no server responds, there is no authentication.
Description of the displayed boxes
The page contains the following boxes:
● RADIUS Authorization Mode
For the login authentication, the RADIUS authorization mode specifies how the rights are
assigned to the user with a successful authentication.
– Conventional
In this mode the user is logged in with administrator rights if the server returns the
value "Administrative User" to the device for the attribute "Service Type". In all other
cases the user is logged in with read rights.
– SiemensVSA
In this mode the assignment of rights depends on whether and which group the server
returns for the user and whether or not there is an entry for the user in the table
"External User Accounts".
SCALANCE XM-400/XR-500 Web Based Management (WBM)
390
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
The table has the following columns:
● Select
Select the row you want to delete.
● Auth. Server Type
Select the which authentication method the server will be used for.
– Login
The server is used only for the login authentication.
– 802.1X
The server is used only for the 802.1X authentication.
– Login & 802.1X
The server is used for both authentication procedures.
● RADIUS Server Address
Enter the IPv4 address or the FQDN (Fully Qualified Domain Name) of the RADIUS
server.
● Server Port
Here, enter the input port on the RADIUS server. As default, input port 1812 is set. The
range of values is 1 to 65535.
● Shared Secret
Enter your access ID here. The range of values is 1...128 characters
● Shared Secret Conf.
Enter your access ID again as confirmation.
● Max. Retrans.
Here, enter the maximum number of retries for an attempted request.
The initial connection attempt is repeated the number of times specified here before
another configured RADIUS server is queried or the login counts as having failed. As
default 3 retries are set, this means 4 connection attempts. The range of values is 1 to
254.
● Primary Server
Using the options in the drop-down list, specify whether or not this server is the primary
server. You can select one of the options "yes" or "no".
● Status
With this check box, you can enable or disable the RADIUS server.
Note
You can configure a maximum of three servers on this page.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
391
Configuring with Web Based Management
5.8 The "Security" menu
Steps in configuration
Entering a new server
1. Click the "Create" button. A new entry is generated in the table.
The following default values are entered in the table:
– Auth. Server Type Login & 802.1X
– RADIUS Server Address: 0.0.0.0
– Server Port: 1812
– Max. Retrans.: 3
– Primary server: No
2. In the relevant row, enter the following data in the input boxes:
– Auth. Server Type Login & 802.1X
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Conf.
– Max. Retrans.: 3
– Primary server: No
3. Click the "Set Values" button.
Repeat this procedure for every server you want to enter.
Modifying servers
1. In the relevant row, enter the following data in the input boxes:
– RADIUS Server Address
– Server Port
– Shared Secret
– Shared Secret Conf.
– Max. Retrans.
– Primary server
2. Click the "Set Values" button.
Repeat this procedure for every server whose entry you want to modify
Deleting servers
1. Click the check box in the first column before the row you want to delete to select the
entry for deletion.
Repeat this for all entries you want to delete.
2. Click the "Delete" button. The data is deleted from the memory of the device and the
page is updated.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
392
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
5.8.4.3
802.1x Authenticator
Setting up network access
An end device can only access the network after the device has verified the login data of the
device with the authentication server. Both the end device and the authentication server
must support the EAP protocol (Extensive Authentication Protocol).
Enabling authentication for individual ports
By enabling the relevant options , you specify for each port whether or not network access
protection according to IEEE 802.1X is enabled on this port.
Figure 5-22
802.1x Authenticator - first part of the table
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
393
Configuring with Web Based Management
5.8 The "Security" menu
Figure 5-23
802.1X Authenticator - second part of the table
Description of the displayed boxes
The page contains the following boxes:
● MAC Authentication
Enable or disable MAC authentication for the device.
● Guest VLAN
Enable or disable the "Guest VLAN" function for the device.
Table 1 has the following columns:
● 1st column
Shows that the settings are valid for all ports of table 2.
● 802.1X Auth. Control
Select the required setting.
If "No Change" is selected, the entry in table 2 remains unchanged.
● 802.1X Re-Authentication
Select the required setting.
If "No Change" is selected, the entry in table 2 remains unchanged.
● MAC Authentication
Select the required setting.
If "No Change" is selected, the entry in table 2 remains unchanged.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
394
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
● RADIUS VLAN Assignment Allowed
Select the required setting.
If "No Change" is selected, the entry in table 2 remains unchanged.
● MAC Auth. Max Allowed Addresses
Specify how many end devices can be connected to the port at the same time.
If "No Change" is selected, the entry in table 2 remains unchanged.
● Guest VLAN
Select the required setting.
If "No Change" is selected, the entry in table 2 remains unchanged.
● Guest VLAN ID
Select the required setting.
If "No Change" is selected, the entry in table 2 remains unchanged.
● Guest VLAN Max Allowed Addresses
Specify how many end devices are permitted in the guest VLAN at the same time.
If "No Change" is selected, the entry in table 2 remains unchanged.
● Copy to table
If you click the button, the settings are adopted for all ports of table 2.
Table 2 has the following columns:
● Port
This column lists all the ports available on this device.
● 802.1X Auth. Control
Specify the authentication of the port:
– Force Unauthorized
Data traffic via the port is blocked.
– Force Authorized
Data traffic via the port is allowed without any restrictions.
Default setting
– Auto
End devices are authenticated on the port with the "802.1X" method.
The data traffic via the port is permitted or blocked depending on the authentication
result.
● 802.1X Re-Authentication
Enable this option if you want reauthentication of an already authenticated end device to
be repeated cyclically.
● MAC Authentication
Enable this option if you want end devices to be authenticated with the "MAC
Authentication" method.
Note
At the port level, you cannot enable "MAC Authentication" and "Guest VLAN" at the same
time.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
395
Configuring with Web Based Management
5.8 The "Security" menu
● RADIUS VLAN Assignment Allowed
The RADIUS server informs the IE switch of the VLAN to which the port will belong.
Enable this option if you want the information of the server to be taken into account. The
port is then assigned to the corresponding VLAN.
If the option is disabled, the original VLAN configuration of the port is restored,
● MAC Auth. Max Allowed Addresses
Enter how many end devices are allowed to be connected to the port at the same time.
● Guest VLAN
Enable this option if you want the end device to be permitted in the "Guest VLAN" if
authentication fails.
Note
At the port level, you cannot enable "MAC Authentication" and "Guest VLAN" at the same
time.
● Guest VLAN ID
Enter the VLAN ID of the guest VLANs.
● Guest VLAN Max Allowed Addresses
Enter how many end devices are allowed in the guest VLAN at the same time.
● 802.1X Auth. Status
Shows the status of the authentication of the port:
– Authorized
– Not Authorized
– Auto
● MAC Auth. Actual Allowed Addresses
Shows the number of currently connected end devices.
● MAC Auth. Actual Blocked Addreses
Shows the number of currently blocked end devices.
● Guest VLAN Actual Allowed Addresses
Shows how many end devices are currently allowed in the guest VLAN.
Steps in configuration
Enabling authentication for an individual port
1. Select the required options in the relevant row in table 2.
2. To apply the changes, click the "Set Values" button.
Enabling authentication for all ports
1. Select the required options in table 1.
2. Click the "Copy to table" button. The check box is enabled for all ports in table 2.
3. To apply the changes, click the "Set Values" button.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
396
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
5.8.5
MAC ACL
5.8.5.1
Rules Configuration
Introduction
On this page, you specify the access rules for the MAC-based Access Control List. Using the
MAC-based ACL, you can specify whether frames of certain MAC addresses are forwarded
or discarded.
Description of the displayed boxes
The table has the following columns:
● Select
Select the row you want to delete.
● Rule Number
Shows the number of the ACL rule. If you click the "Create" button, a new row with a
unique number is created.
● Source MAC
Enter the unicast MAC address of the source.
● Dest. MAC
Enter the unicast MAC address of the destination.
● Action
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule.
– Forward
If the frame complies with the ACL rule, the frame is forwarded.
– Discard
If the frame complies with the ACL rule, the frame is not forwarded.
● Ingress Interfaces
Shows a list of all ingress ports to which this rule applies.
● Egress Interfaces
Shows a list of all egress ports to which this rule applies.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
397
Configuring with Web Based Management
5.8 The "Security" menu
Note
Entering the MAC addresses
If you enter the address "00:00:00:00:00:00" for the source and/or destination MAC address,
the rule created in this way applies to all source or destination MAC addresses.
Steps in configuration
1. Click the "Create" button. A new row with a unique number (rule number) is created in the
table.
2. Enter the MAC address of the source in "Source MAC".
3. Enter the MAC address of the destination in "Dest MAC".
4. In the "Action" drop-down list select whether the frame is forwarded or rejected when it
corresponds to the ACL rule.
5.8.5.2
Ingress Rules
Introduction
On this page, you specify the ACL rule according to which incoming frames are filtered at a
port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
398
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
Description of the displayed boxes
The page contains the following boxes:
● Ports
Select the required port from the drop-down list.
● Add Rule
From the drop-down list, select the ACL rule that will be assigned to the port. You specify
the ACL rules in the "Rules Configuration" tab.
● Add
To permanently assign the ACL rule to the port, click the "Add" button. The configuration
is shown in the table.
● Remove Rule
From the "Remove rule" drop-down list, select the ACL rule to be deleted.
● Remove
To remove the ACL rule from the port, click the "Remove" button.
The table has the following columns:
● Rule Order
Shows the order of the ACL rules.
● Rule Number
Shows the number of the ACL rule.
● Source MAC
Shows the unicast MAC address of the source.
● Dest. MAC
Shows the unicast MAC address of the destination.
● Action
Shows the action.
– Forward
If the frame complies with the ACL rule, the frame is forwarded.
– Discard
If the frame complies with the ACL rule, the frame is not forwarded.
Steps in configuration
Follow the steps below to assign an ACL rule to a port:
1. Select the port in the "Ports" drop-down list.
2. Select the ACL rule in the "Add Rule" drop-down list.
3. Click the "Add" button. A new entry is generated in the table.
Follow the steps below to remove an ACL rule from a port:
1. Select the port in the "Ports" drop-down list.
2. Select the ACL rule in the "Remove Rule" drop-down list.
3. Click the "Remove" button. The corresponding entry is removed in the table.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
399
Configuring with Web Based Management
5.8 The "Security" menu
5.8.5.3
Egress Rules
Introduction
On this page, you specify the ACL rules according to which outgoing frames are filtered at a
port.
Description of the displayed boxes
The page contains the following boxes:
● Ports
Select the required port from the drop-down list.
● Add Rule
From the drop-down list, select the ACL rule that will be assigned to the port. You specify
the ACL rule in the "Rules Configuration" tab.
● Add
To permanently assign the ACL rule to the port, click the "Add" button. The configuration
is shown in the table.
● Remove Rule
From the "Remove rule" drop-down list, select the ACL rule to be deleted.
● Remove
To remove the ACL rule from the port, click the "Remove" button.
The table has the following columns:
● Rule Order
Shows the order of the ACL rules.
● Rule Number
Shows the number of the ACL rule.
● Source MAC
Shows the unicast MAC address of the source.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
400
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
● Dest. MAC
Shows the unicast MAC address of the destination.
● Action
Shows the action.
– Forward
If the frame complies with the ACL rule, the frame is forwarded.
– Discard.
If the frame complies with the ACL rule, the frame is not forwarded.
Steps in configuration
Follow the steps below to assign an ACL rule to a port:
1. Select the port in the "Ports" drop-down list.
2. Select the ACL rule in the "Add Rule" drop-down list.
3. Click the "Add" button. A new entry is generated in the table.
Follow the steps below to remove an ACL rule from a port:
1. Select the port in the "Ports" drop-down list.
2. Select the ACL rule in the "Remove Rule" drop-down list.
3. Click the "Remove" button. The corresponding entry is removed in the table.
5.8.6
IP ACL
5.8.6.1
Rules Configuration
Introduction
On this page, you specify the rules for the IP-based Access Control List. Using the IP-based
ACL, you can specify whether frames of certain IPv4 addresses are forwarded or discarded.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
401
Configuring with Web Based Management
5.8 The "Security" menu
Description of the displayed boxes
The table has the following columns:
● Select
Select the row you want to delete.
● Rule Number
Shows the number of the ACL rule. If you click the "Create" button, a new row with a
unique number is created.
● Source IP
Enter the IPv4 address of the source.
● Source Subnet Mask
Enter the subnet mask of the source.
● Dest. IP
Enter the IPv4 address of the destination.
● Dest. Subnet Mask
Enter the subnet mask of the destination.
● Action
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule.
– Forward
If the frame complies with the ACL rule, the frame is forwarded.
– Discard
If the frame complies with the ACL rule, the frame is not forwarded.
● Ingress Interfaces
Shows a list of all ingress interfaces to which this rule applies.
● Egress Interfaces
Shows a list of all egress interfaces to which this rule applies.
Note
Subnet mask for individual hosts
If you create the rule for a single system (one IPv4 address), specify the subnet mask
"255.255.255.255".
Steps in configuration
1. Click the "Create" button. A new row with a unique number (rule number) is created in the
table.
2. Enter the data of the source in "Source IP" and in "Source Subnet Mask".
3. Enter the data of the destination in "Dest. IP" and in "Dest. Subnet Mask".
4. In the "Action" drop-down list select whether the frame is forwarded or rejected when the
frame corresponds to the ACL rule.
5. On the "Protocol Configuration " tab, you specify the rules for protocols.
6. In the "Ingress Rules" and "Egress Rules", select how incoming and outgoing frames are
handled by a port.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
402
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
5.8.6.2
Protocol Configuration
On this page, you specify the rules for protocols.
Settings
Figure 5-24
IP ACL Protocol Configuration
The table has the following columns:
● Rule Number
Shows the number of the protocol rule. When you create a rule, a new row with a unique
number is created.
● Protocol
Select the protocol for which this rule is valid.
● Protocol Number
Enter a protocol number to define further protocols.
This box can only be edited if you have set "Other Protocol" for the protocol .
● Source Port Min.
Enter the lowest possible port number of the source port.
This box can only be edited if you have set "TCP" or "UDP" for the protocol.
● Source Port Max.
Enter the highest possible port number of the source port.
This box can only be edited if you have set "TCP" or "UDP" for the protocol.
● Dest. Port Min.
Enter the lowest possible port number of the destination port.
This box can only be edited if you have set "TCP" or "UDP" for the protocol.
● Dest. Port Max.
Enter the highest possible port number of the destination port.
This box can only be edited if you have set "TCP" or "UDP" for the protocol.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
403
Configuring with Web Based Management
5.8 The "Security" menu
● Message Type
Enter a message type to decide the format of the message.
This box can only be edited if you have set "ICMP" for the protocol.
● Message Code
Enter a message code to specify the function of the message.
This box can only be edited if you have set "ICMP" for the protocol.
● DSCP
Enter a value for classifying the priority.
This box cannot be edited if you have set "ICMP" for the protocol.
5.8.6.3
Ingress Rules
Introduction
On this page, you specify the ACL rules according to which incoming frames are handled by
a port or VLAN.
Figure 5-25
IP ACL ingress rules - first part of the table
SCALANCE XM-400/XR-500 Web Based Management (WBM)
404
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
Figure 5-26
IP ACL ingress rules - second part of the table
Description of the displayed boxes
The page contains the following boxes:
● Ports
Select the required port from the drop-down list. a port or a VLAN interface.
To select a VLAN interface, an IP interface must be configured.
Note
If you use a VLAN interface, the ACL rule applies to all ports that belong to the VLAN.
● Add Rule
From the drop-down list, select the ACL rule that will be assigned to the port. You specify
the ACL rules in the "Rules Configuration" tab.
● Add
To permanently assign the ACL rule to the port, click the "Add" button. The configuration
is shown in the table.
● Remove Rule
From the "Remove rule" drop-down list, select the ACL rule to be deleted.
● Remove
To remove the ACL rule from the port, click the "Remove" button.
The table has the following columns:
● Rule Order
Shows the order of the ACL rules.
● Rule Number
Shows the number of the ACL rule. If you click the "Create" button, a new row with a
unique number is created.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
405
Configuring with Web Based Management
5.8 The "Security" menu
● Protocol
Shows the protocol for which this rule is valid.
● Protocol Number
Shows the protocol number.
● Source IP
Shows the IPv4 address of the source.
● Source Subnet Mask
Shows the subnet mask of the source.
● Dest IP
Shows the IP address of the destination.
● Dest. Subnet Mask
Shows the subnet mask of the destination.
● Action
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule.
– Forward
If the frame complies with the ACL rule, the frame is forwarded.
– Discard
If the frame complies with the ACL rule, the frame is not forwarded.
● Source Port Min.
Shows the lowest possible port number of the source port.
● Source Port Max.
Shows the highest possible port number of the source port.
● Dest. Port Min.
Shows the lowest possible port number of the destination port.
● Dest. Port Max.
Shows the highest possible port number of the destination port.
● Message Type
Shows a message type to decide the format of the message.
● Message Code
Shows a message code to specify the function of the message.
● DSCP
Shows a value for classifying the priority.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
406
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
Steps in configuration
Follow the steps below to assign an ACL rule to a port or a VLAN interface:
1. Select the port or the VLAN interface in the "Ports" drop-down list.
2. Select the ACL rule in the "Add Rule" drop-down list.
3. Click the "Add" button. A new entry is generated in the table.
Follow the steps below to assign an ACL rule to a port or a VLAN interface:
1. Select the port or the VLAN interface in the "Ports" drop-down list.
2. Select the ACL rule in the "Remove Rule" drop-down list.
3. Click the "Remove" button. The corresponding entry is deleted.
5.8.6.4
Egress Rules
Introduction
On this page, you specify the ACL rule according to which outgoing frames are handled by a
port.
Figure 5-27
IP ACL egress rules - first part of the table
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
407
Configuring with Web Based Management
5.8 The "Security" menu
Figure 5-28
IP ACL egress rules - second part of the table
Description of the displayed boxes
The page contains the following boxes:
● Ports
Select the required port from the drop-down list. a port or a VLAN interface.
To select a VLAN interface, an IP interface must be configured.
Note
If you use a VLAN interface, the ACL rule applies to all ports that belong to the VLAN.
● Add Rule
From the drop-down list, select the ACL rule that will be assigned to the port. You specify
the ACL rules in the "Rules Configuration" tab.
● Add
To permanently assign the ACL rule to the port, click the "Add" button. The configuration
is shown in the table.
● Remove Rule
From the "Remove rule" drop-down list, select the ACL rule to be deleted.
● Remove
To remove the ACL rule from the port, click the "Remove" button.
The table has the following columns:
● Rule Order
Shows the order of the ACL rules.
● Rule Number
Shows the number of the ACL rule. If you click the "Create" button, a new row with a
unique number is created.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
408
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
● Protocol
Shows the protocol for which this rule is valid.
● Protocol Number
Shows the protocol number.
● Source IP
Shows the IPv4 address of the source.
● Source Subnet Mask
Shows the subnet mask of the source.
● Dest IP
Shows the IP address of the destination.
● Dest. Subnet Mask
Shows the subnet mask of the destination.
● Action
Select whether the frame is forwarded or rejected when it corresponds to the ACL rule.
– Forward
If the frame complies with the ACL rule, the frame is forwarded.
– Discard
If the frame complies with the ACL rule, the frame is not forwarded.
● Source Port Min.
Shows the lowest possible port number of the source port.
● Source Port Max.
Shows the highest possible port number of the source port.
● Dest. Port Min.
Shows the lowest possible port number of the destination port.
● Dest. Port Max.
Shows the highest possible port number of the destination port.
● Message Type
Shows a message type to decide the format of the message.
● Message Code
Shows a message code to specify the function of the message.
● DSCP
Shows a value for classifying the priority.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
409
Configuring with Web Based Management
5.8 The "Security" menu
Steps in configuration
Follow the steps below to assign an ACL rule to a port or a VLAN interface:
1. Select the port or the VLAN interface in the "Ports" drop-down list.
2. Select the ACL rule in the "Add Rule" drop-down list.
3. Click the "Add" button. A new entry is generated in the table.
Follow the steps below to assign an ACL rule to a port or a VLAN interface:
1. Select the port or the VLAN interface in the "Ports" drop-down list.
2. Select the ACL rule in the "Remove Rule" drop-down list.
3. Click the "Remove" button. The corresponding entry is deleted.
5.8.7
Management ACL
Description of configuration
On this page, you can increase the security of your device. To specify which station with
which IPv4 address is allowed to access your device, configure the IPv4 address or an entire
address range.
You can select the protocols and the ports of the station with which it is allowed to access
the device. You define the VLAN in which the station may be located. This ensures that only
certain stations within a VLAN have access to the device.
Description of the displayed boxes
Note
If you enable this function, note the following
A bad configuration on the "Management Access Control List" page can result in you being
unable to access the device. You should therefore configure an access rule that allows
access to the management before you enable the function.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
410
Configuration Manual, 11/2015, C79000-G8976-C248-10
Configuring with Web Based Management
5.8 The "Security" menu
The page contains the following boxes:
● Management ACL
Enable or disable access control to the management of the IE switch.
As default, the function is disabled.
Note
If the function is disabled, there is unrestricted access to the management of the IE
switch. The configured access rules are only taken into account when the function is
enabled.
● IP Address
Enter the IPv4 address or the network address from which the rule will apply. If you use
the IPv4 address 0.0.0.0, the settings apply to all IPv4 addresses.
● Subnet Mask
Enter the subnet mask. The subnet mask 255.255.255.255 is for a specific IPv4 address.
If you want to allow a subnet, for example a C subnet, enter 255.255.255.0. The subnet
mask 0.0.0.0 applies to all subnets.
The table has the following columns:
● Select
Select the row you want to delete.
● Rule Order
Shows the order of the ACL rules.
● IP address
Shows the IPv4 address.
● Subnet Mask
Shows the subnet mask.
● VLANs Allowed
Enter the number of the VLAN in which the device is located. The station can only access
the device if it is located in this configured VLAN. If this input box remains empty, there is
no restriction relating to the VLANs.
● Out-Band
Specify whether or not the IPv4 address can access the switch via the out-band port.
● SNMP
Specify whether the station (or the IPv4 address) can access the device using the SNMP
protocol.
● TELNET
Specify whether the station (or the IPv4 address) can access the device using the
TELNET protocol.
● HTTP
Specify whether the station (or the IPv4 address) can access the device using the HTTP
protocol.
● HTTPS
Specify whether the station (or the IPv4 address) can access the switch using the HTTPS
protocol.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
411
Configuring with Web Based Management
5.8 The "Security" menu
● SSH
Specify whether the station (or the IPv4 address) can access the switch using the SSH
protocol.
● Px.y
Specify whether the station (or the IPv4 address) can access this device via this port
(slot.port).
Steps in configuration
Changing the entry
1. Configure the data of the entry you want to modify.
2. Click the "Set Values" button to transfer the changes to the device.
Creating a new entry
Note
Note that a bad configuration may mean that you can no longer access the device.
You can then only remedy this by resetting the device to the factory defaults and then
reconfiguring.
1. In the "IP Address" input box, enter the IPv4 address of the device and in the "Subnet
Mask" input box the corresponding subnet mask.
2. Click the "Create" button to create a new row in the table.
3. Configure the entries of the new row.
4. Click the "Set Values" button to transfer the new entry to the device.
Deleting entries
1. Select the check box in the row to be deleted.
2. Repeat this procedure for every entry you want to delete.
3. Click the "Remove" button. The entries are deleted and the page is updated.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
412
Configuration Manual, 11/2015, C79000-G8976-C248-10
Troubleshooting/FAQ
6.1
6
Firmware update via WBM or CLI not possible
Cause
If there is a power failure during the firmware update, it is possible that the IE switch is no
longer accessible using Web Based Management or the Command Line Interface.
Solution
If the IE switch cannot be reached using WBM or CLI, you can download the firmware to
your IE switch using TFTP.
Follow the steps below to load new firmware using TFTP:
1. Turn off the power to the IE switch.
2. Press the Reset button and reconnect the power to the IE switch while holding down the
button.
3. Hold down the button until the red fault LED (F) starts to flash after approximately 30
seconds.
4. Release the button.
The bootloader waits in this state for a new firmware file that you can download by TFTP.
5. Connect a PC via the Ethernet interface with the out-band interface of the IE switch.
6. Assign an IP address to the IE switch with the Primary Setup Tool.
7. In the command prompt, change to the directory where the file with the new firmware is
located and then execute the command "tftp -i <ip address> PUT <firmware>". As an
alternative, you can use a different TFTP client.
Result
The firmware is transferred to the IE switch.
Note
Please note that the transfer of the firmware can take several minutes. During the
transmission, the red error LED (F) flashes.
Once the firmware has been transferred completely to the IE switch, the IE switch is
restarted automatically.
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
413
Troubleshooting/FAQ
6.1 Firmware update via WBM or CLI not possible
SCALANCE XM-400/XR-500 Web Based Management (WBM)
414
Configuration Manual, 11/2015, C79000-G8976-C248-10
Index
1
1588, 289
A
Access control, 273, 275
Automatic learning, 275
ACL, 275, 410
Aging
Dynamic MAC Aging, 241
Aging time, 280, 285
Alarm events, 149
Authentication, 158, 393
B
Bridge, 249
Bridge priority, 249
Root bridge, 249
Bridge Max Age, 250
Bridge Max Hop Count, 250
Broadcast, 287
Button, 177
C
Cable test, 205
Class of Service, 213
Collisions, 93
Combo port, 14
Combo Port Media Type, 182, 187
Configuration mode, 130
CoS, 213
Traffic queue, 214
CoS (Class of Service), 35
C-PLUG
Formatting, 196
Saving the configuration, 196
C-PLUG / KEY-PLUG, 16
CRC, 93
D
DCP server, 129, 266
DHCP
Client, 151
DHCPv4 Relay Agent
General settings, 354
DHCPv6
Client, 343
PD Sub Client, 345
Prefix delegation, 343, 345
DNS client, 134
DSCP, 215
DST
Daylight saving time, 162, 164
E
E-Mail function, 149
Alarm events, 149
Line monitoring, 149
Error status, 76
Ethernet Statistics
Frame Type, 91
History, 94
Interface statistics, 89
Packet Error, 92
Packet Size, 90
Event log table, 74
Events
Log Table, 74
F
Fault monitoring
Connection status change, 191
Redundancy, 193
Filter
Filter configuration, 273
Forward Delay, 250
Fragments, 93
G
Geographic coordinates, 132
Glossary, 11
GMRP, 282
Groups, 382
GVRP, 223
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
415
Index
H
J
Hardware Revision, 71
Hello time, 250
HRP, 245
HTTP
Load/save, 137
HTTPS
Server, 128
Jabbers, 93
I
IEEE 1588, 289
IGMP, 280
Information
ARP table, 72
Groups, 127
IPv6 Neighbor Table, 73
LLDP, 98
Log Table, 74
Ring redundancy, 85, 87
Role, 126
Security, 123, 125
SNMP, 121, 122
Spanning Tree, 77
Start page, 64
Versions, 69
IPv4
OSPF, 40
VRRP, 39
VRRPv3, 39
IPv4 address, 133
IPv4 routing
OSPFv2 interfaces, 102
OSPFv2 LSDB (information), 107
OSPFv2 neighbors, 103
OSPFv2 Virtual Neighbors, 105
RIPv2 Statistics, 108
Routing table, 101
IPv6, 14
Notation, 28
OSPFv3, 44
VRRPv3, 39
IPv6 addresses, 14
IPv6 routing
OSPFv3 AS-Scope LSDB, 116, 117
OSPFv3 Interfaces, 110
OSPFv3 Link-Scope LSDB, 119
OSPFv3 Neighbors, 112
OSPFv3 virtual neighbors, 114
Routing table, 109, 120
Static routes, 346
K
KEY-PLUG, 194, 198, 198
Formatting, 196
L
LACP, 263
Layer 2, 209
MLD (IPv6), 286
Layer 3, 198, 198
Layer 3 (IPv4), 295
Configuration, 295
Layer 3 (IPv6), 340
Configuration, 340
Line monitoring, 149
LLDP, 98, 268
Local users, 384
Location, 132
Logging on
via HTTP, 61
via HTTPS, 61
Logout
Automatic, 176
Loop, 261
Loop detection, 261, 261
M
MAC ACL, 397, 398
Configuration, 398, 400
Maintenance data, 70
Management ACL, 410
Manufacturer, 70
Manufacturer ID, 71
Mirroring, 231
General, 232
IP Flow, 240
MAC Flow, 239
Port, 237
VLAN, 238
MLD, 285
MSTP, 248, 255
Port, 251
Port parameters, 256
MSTP instance, 256, 257
Multicast, 277
SCALANCE XM-400/XR-500 Web Based Management (WBM)
416
Configuration Manual, 11/2015, C79000-G8976-C248-10
Index
Multiple Spanning Tree, 251, 255
N
Near Field Communication, 130
Negotiation, 182
NFC, 130
NTP, 277
Client, 171
O
Order ID, 71
OSPF
Areas, 40
Link State Advertisement, 40
Router, 40
Router status, 40
OSPF (IPv4)
Area range, 327
Areas, 326
Configuration, 324
Interface authentication, 331
OSPFv2 interfaces, 102
OSPFv2 Interfaces, 329
OSPFv2 LSDB (information), 107
OSPFv2 neighbors, 103
OSPFv2 Virtual Neighbors, 105
Virtual link authentication, 335
Virtual Links, 333
OSPF (IPv6)
Area Range, 368
Areas, 366, 366
OSPFv3 AS-Scope LSDB, 116, 117
OSPFv3 interfaces, 370
OSPFv3 Interfaces, 110
OSPFv3 Link-Scope LSDB, 119
OSPFv3 Neighbors, 112
OSPFv3 virtual neighbors, 114
Virtual Links, 372
OSPFv3
Configuration, 364
Oversize, 93
P
Packet error statistics, 92
Password, 387
Ping, 199
PLUG, 198, 198
C-PLUG, (C-PLUG)
KEY-PLUG, (KEY-PLUG)
PNIO, 193
PoE, 200, 202
Port, 202
point-to-point, 48
Port, 185
Port configuration, 181, 189
Port configuration, 185, 189
Port diagnostics
Cable test, 205
SFP diagnostics, 207
Power over Ethernet, 18, 200
Port, 202
Power supply
Monitoring, 189
Prioritization, 216
Priority, 216, 250
PROFINET IO, 193
PST tool, 266
PTP, 289, 290, 290
General, 290
Port, 290
Transparent clock, 290
Q
QoS, 216
R
RADIUS, 390
Rate control, 218
Reboot, 136
Redundancy, 243, 245
Redundancy methods
HRP, 49
Redundant networks, 249
Reset, 136
RFC
RFC 1518, 23
Ring redundancy, 243
HRP, 211, 243
MRP, 211, 243
Ring ports, 243
Standby, 245
RIP (IPv4)
RIPv2 Statistics, 108
RIPng
Configuration, 375
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
417
Index
Interfaces, 376
RIPng Statistics, 120
RIPv2
Configuration, 337
Interfaces, 338
RMON
History, 293
Statistics, 292
Roles, 380
Root Max Age, 250
Route Map, 302, 348
Route maps, 302, 348
Routing, 38, 38, 300
IPv4 routing table, 101
IPv6 routing table, 109
Static IPv4 routes, 300
Static routes, 38, 38
VRRP, 38
RSTP, 248
Rule, 397, 398, 401
Configuration, 401
Egress, 400, 401
Ingress, 398, 401
IP ACL, 401
S
Scope of the manual, 9
Security settings, 155
Select/Set button, 177
Serial number, 71
SFP diagnostics, 207
SHA algorithm, 155
SIMATIC NET glossary, 11
SMTP
Client, 129
SNMP, 36, 129, 152, 155
Groups, 155
Overview, 121
SNMPv1, 36
SNMPv2c, 36
SNMPv3, 36
Trap, 154
Users, 157
Software version, 71
Spanning tree, 248
MSTP, 248
Passive listening, 259
RSTP, 248
Spanning Tree
Information, 77
Rapid Spanning Tree, 48
SSH
Server, 128
Standby, 245
Standby redundancy, 57
Start page, 64
Static routes
IPv6 routes, 346
STEP 7, 266
STP, 248
Subnet mask, 23
Subnets
Configuration (IPv4), 299
Configuration (IPv6), 341
Connected Subnets (IPv6), 341
Overview (IPv4), 296
Syslog, 179
Client, 129
System
Configuration, 128
General information, 131
System event log
Agent, 179
System events
Configuration, 145
Severity filter, 148
T
Telnet
Server, 128
TFTP
Load/save, 141
Time, 129
Time of day
Manual setting, 160
Precision Time Protocol, 174
PTP Client, 174
SIMATIC Time Client, 173
SNTP (Simple Network Time Protocol), 168
System time, 160
Time zone, 170
Time-of-day synchronization, 168
UTC time, 170
Time setting, 129
Trust Mode, 216
U
Undersize, 93
User Groups, 382
SCALANCE XM-400/XR-500 Web Based Management (WBM)
418
Configuration Manual, 11/2015, C79000-G8976-C248-10
Index
V
VLAN, 33, 227
Group, 227
Port VID, 226
Priority, 226
Tag, 226
VLAN ID, 35
VLAN tag, 34
VRRP
Backup router, 39
Master router, 39
Virtual router, 39
VRRP address configuration (IPv4), 316
VRRP address overview (IPv4), 315
VRRP addresses overview (IPv4), 322
VRRP configuration (IPv4), 314
VRRP router, 39
VRRP routers (IPv4), 311, 317, 358
VRRP statistics, 80
VRRPv3 address configuration (IPv6), 363
VRRPv3 Addresses Configuration (IPv4), 323
VRRPv3 addresses overview (IPv6), 362
VRRPv3 Configuration (IPv4), 320
VRRPv3 Configuration (IPv6), 360
VRRPv3
VRRPv3 Statistics, 83
W
Web Based Management, 59
Requirement, 59
SCALANCE XM-400/XR-500 Web Based Management (WBM)
Configuration Manual, 11/2015, C79000-G8976-C248-10
419
Index
SCALANCE XM-400/XR-500 Web Based Management (WBM)
420
Configuration Manual, 11/2015, C79000-G8976-C248-10
Was this manual useful for you? yes no
Thank you for your participation!