Split Air Conditioner
Split Air Conditioner
OWNER'S MANUAL
LENNOX A I R C O N D I T I O N E R S
MODEL:
LM012CI-100P432-1
LM012CO-100P432-1
Thank you for selecting LENNOX air conditioners.Please read this manual
carefully before operation and keep it for further reference.
Content
Operation Notices
Precautions............................................................................................................1
Parts Name............................................................................................................6
ScreenOperation Guide
Buttons on remote controller .................................................................................8
Introduction for icons on display screen ............................................................... 8
Introduction for buttons on remote controller ....................................................... .9
Function introduction for combination buttons .....................................................12
Operation guide ...................................................................................................13
Replacement of batteries in remote controller .....................................................13
Emergency operation .......................................................................................... 14
Maintenance
Clean and Maintenance....................................................................................... 14
Malfunction
Malfunction analysis ............................................................................................17
Installation Notice
Installation dimension diagram ............................................................................21
Tools for installation.............................................................................................22
Selection of installation location ..........................................................................22
Requirements for electric connection ..................................................................23
Installation
Installation of indoor unit......................................................................................24
Installation of outdoor unit ...................................................................................29
Vacuum pumping.................................................................................................32
Leakage detection ...............................................................................................32
Check after installation ........................................................................................33
Test and operation
Test operation......................................................................................................33
Attachment
Configuration of connection pipe .........................................................................34
Pipe expanding method .......................................................................................36
Precautions
WARNING
Operation and Maintenance
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by
children without supervision.
Do not connect air conditioner to multi-purpose socket.
Otherwise, it may cause fire hazard.
Do disconnect power supply when cleaning air
conditioner. Otherwise, it may cause electric shock.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Do not wash the air conditioner with water to avoid
electric shock.
Do not spray water on indoor unit. It may cause electric
shock or malfunction.
After removing the filter, do not touch fins to avoid injury.
Do not use fire or hair dryer to dry the filter to avoid
deformation or fire hazard.
1
Precautions
WARNING
Maintenance must be performed by qualified
professionals. Otherwise, it may cause personal injury
or damage.
Do not repair air conditioner by yourself. It may cause
electric shock or damage. Please contact dealer when
you need to repair air conditioner.
Do not extend fingers or objects into air inlet or air
outlet. It may cause personal injury or damage.
Do not block air outlet or air inlet. It may cause
malfunction.
Do not spill water on the remote controller, otherwise the
remote controller may be broken.
When below phenomenon occurs, please turn off air
conditioner and disconnect power immediately, and then
contact the dealer or qualified professionals for service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
If the air conditioner operates under abnormal conditions,
it may cause malfunction, electric shock or fire hazard.
When turning on or turning off the unit by emergency
operation switch, please press this switch with an insulating
object other than metal.
Do not step on top panel of outdoor unit, or put heavy
objects. It may cause damage or personal injury.
2
Precautions
WARNING
Attachment
Installation must be performed by qualified professionals.
Otherwise, it may cause personal injury or damage.
Must follow the electric safety regulations when installing
the unit.
According to the local safety regulations, use qualified
power supply circuit and circuit break.
Do install the circuit break. If not, it may cause malfunction.
An all-pole disconnection switch having a contact separation
of at least 3mm in all poles should be connected in fixed
wiring.
Including an circuit break with suitable capacity, please
note the following table.Air switch should be included
magnet buckle and heating buckle function, it can protect
the circuit-short and overload.
Air Conditioner should be properly grounded. Incorrect
grounding may cause electric shock.
Don't use unqualified power cord.
Make sure the power supply matches with the
requirement of air conditioner. Unstable power supply or
incorrect wiring or malfunction. Please install proper power
supply cables before using the air conditioner.
Properly connect the live wire, neutral wire and
grounding wire of power socket.
Be sure to cut off the power supply before proceeding
any work related to electricity and safety.
3
Precautions
WARNING
Do not put through the power before finishing installation.
If the supply cord is damaged, it must be replaced by
the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
The appliance shall be installed in accordance with
national wiring regulations.
Installation must be performed in accordance with the
requirement of NEC and CEC by authorized personnel
only.
The air conditioner is the first class electric appliance. It
must be properly grounding with specialized grounding
device by a professional. Please make sure it is always
grounded effectively, otherwise it may cause electric shock.
The yellow-green wire in air conditioner is grounding
wire, which can't be used for other purposes.
The grounding resistance should comply with national
electric safety regulations.
The appliance must be positioned so that the plug is
accessible.
All wires of indoor unit and outdoor unit should be
connected by a professional.
If the length of power connection wire is insufficient, please
contact the supplier for a new one. Avoid extending the
wire by yourself.
4
Precautions
WARNING
For the air conditioner with plug, the plug should be
reachable after finishing installation.
For the air conditioner without plug, an circuit break
must be installed in the line.
If you need to relocate the air conditioner to another
place, only the qualified person can perform the work.
Otherwise, it may cause personal injury or damage.
Select a location which is out of reach for children and
far away from animals or plants. If it is unavoidable,
please add the fence for safety purpose.
The indoor unit should be installed close to the wall.
Working temperature range
Maximum cooling
Maximum heating
Indoor side DB/WB(℃ )
32/23
27/-
NOTICE:
Outdoor side DB/WB(℃ )
43/26
24/18
● The operating temperature range (outdoor temperature) for cooling only unit is
18℃ ~ 43℃ ; for heat pump unit is -7℃ ~ 43℃ .
5
Parts Name
Indoor Unit
air inlet
panel
aux.button
horizontal louver
air outlet
(Display content or position may be different from above
graphics, please refer to actual products)
remote control
Outdoor Unit
air inlet
Connection wire
air outlet
NOTICE:
Actual product may be different from above graphics, please refer to actual
products.
6
Parts Name
Display
For some model:
cooling
indicator
For some model:
power
indicator
receiver
window
heating
indicator
temp.
indicator
display
cooling
indicator
heating
indicator
temp.
indicator
drying
display
indicator
For some model:
receiver
window
power
indicator
drying
indicator
display
temp.
indicator
Power LED color indicator:
Green-status-ON.
Red-status-OFF.
receiver
window
Mode LED color indicator:
W
R
G
White-W-Cool ModeRed-R-Heat Mode-
W
(only for heating model)
R
Green-G-Dry Mode- G
For some model:
display
temp.
indicator
Power LED color indicator:
Green-status-ON.
Red-status-OFF.
receiver
window
Mode LED color indicator:
W
R
O
White-W-Cool ModeRed-R-Heat Mode-
R
W
(only for heating model)
Orange-O-Dry Mode- O
A5/B2/B4Panel:After energization, dual-8 nixie tube and power indicator blink once.
Under standby status, the power indicator is in red. After turning on the unit by remote
controller, power indicator is off. The dual-8 nixie tube displays current set temperature.
(Note: No operation indicator, heating indicator, cooling indicator and dry indictor for
models with A5 or B2 or B4 panels. Therefore, no mode indicator display during
operation status.)
Display content or position may be different from above graphics, please refer to actual
products.
7
Buttons on remote controller
9
▲ button
3
MODE button
4
SWING button
button
6
FAN button
7
TIMER OFF button
8
CLOCK button
4
9
TIMER ON button
5
6
2
▲
3
ON/OFF button
5
1
2
1
8
7
10 SLEEP button
10
12
11
11 TEMP button
15
13
12 TURBO button
13 X-FAN
14
button
14 I FEEL button
15
/
button
Introduction for icons on display screen
Set fan speed
I feel
Send signal
Turbo mode
8℃ heating function
Operation mode
ventilation operation
health function
X-fan mode
Auto mode
Cool mode
Dry mode
Fan mode
Heat mode
Set temperature
Set time
TIMER ON /
TIMER OFF
Child lock
Clock
Sleep mode
Light
Up & down swing
Temp. display type
:Set temp.
:Indoor ambient temp.
:Outdoor ambient temp.
8
Introduction for buttons on remote controller
Note:
● After putting through the power, the air conditioner will give out a sound.
Operation indictor " " is ON (red indicator). After that, you can operate the air
conditioner by using remote controller.
● Under on status, pressing the button on the remote controller, the signal icon " "
on the display of remote controller will blink once and the air conditioner will give
out a “de” sound, which means the signal has been sent to the air conditioner.
● Under off status, set temperature and clock icon will be displayed on the display
of remote controller (If timer on, timer off and light functions are set, the corresponding icons will be displayed on the display of remote controller at the same
time); Under on status, the display will show the corresponding set function icons.
1
ON/OFF button
2
▲ button
Press this button to turn on the unit. Press this button again to turn off the unit.
Press this button to increase set temperature. Holding it down above 2 seconds rapidly
increases set temperature. In AUTO mode, set temperature is not adjustable.
3
MODE button
Each time you press this button,a mode is selected in a sequence that goes from
AUTO, COOL, DRY, FAN, and HEAT *, as the following:
AUTO
COOL
DRY
FAN
HEAT*
* Note: Only for models with heating function.
After energization, AUTO mode is defaulted. In AUTO mode, the set temperature will
not be displayed on the LCD, and the unit will automatically select the suitable operation mode in accordance with the room temperature to make indoor room comfortable.
4
SWING button
Press this button to set up & down swing angle, which circularly changes as below:
OFF
This remote controller is universal. If any command
the unit will carry out the command as
,
or
is sent out,
indicates the guide louver swings as:
▲
5
button
Press this button to decrease set temperature. Holding it down above 2 seconds rapidly
decreases set temperature. In AUTO mode, set temperature is not adjustable.
9
Introduction for buttons on remote controller
6
FAN button
This button is used for setting Fan Speed in the sequence that goes from AUTO,
, to
, then back to Auto.
Auto
Low speed
7
Medium speed
High speed
TIMER OFF button
Press this button to initiate the auto-off timer. To cancel the auto-timer program, simply
press the button again. TIMER OFF setting is the same as TIMER ON.
8
CLOCK button
Press CLOCK button,
blinking. Within 5 seconds, pressing ▲ or button adjusts the
present time. Holding down either button above 2 seconds increases or decreases the
time by 1 minute every 0.5 second and then by 10 minutes every 0.5 second. During
blinking after setting, press CLOCK button again to confirm the setting, and then
will be constantly displayed.
▲
9
TIMER ON button
Press this button to initiate the auto-ON timer. To cancel the auto-timer program, simply
press this button again.
After press of this button, disappears and "ON "blinks. 0 0:00 is displayed for ON time
setting. Within 5 seconds, press ▲ or button to adjust the time value. Every press of
either button changes the time setting by 1 minute. Holding down either button rapidly
changes the time setting by 1 minute and then 10 minutes. Within 5 Seconds after
setting, press TIMER ON button to confirm.
▲
10
SLEEP button
Press this button to go into the SLEEP operation mode. Press it again to cancel this
function. This function is available in COOL, HEAT (Only for models with heating
function) to maintain the most comfortable temperature for you.
11
TEMP button
Press this button, you can see indoor set temperature, indoor ambient temperature
on indoor unit’s display. The setting on remote controller is selected circularly as below:
no display
When selecting "
" with remote controller or no display, temperature indicator on indoor
10
Introduction for buttons on remote controller
unit displays set temperature; When selecting " " with remote controller, temperature
indicator on indoor unit displays indoor ambient temperature; 3s later or within 3s it
receives other remote controller signal that will return to display the setting temperature.
Caution:
• This model hasn't outdoor ambient temperature display function. While remote controller
can operate "
" and indoor unit displays set temperature.
• It’s defaulted to display set temperature when turning on the unit.
• Only for the models with temperature indicator on indoor unit.
12
TURBO button
13
X-FAN
14
I FEEL button
Press this button to activate / deactivate the Turbo function which enables the unit to
reach the preset temperature in the shortest time. In COOL mode, the unit will blow
strong cooling air at super high fan speed. In HEAT mode, the unit will blow strong
heating air at super high fan speed.
button
X-FAN function: In COOL or DRY mode, the icon is displayed and the indoor fan will
continue operation for 2 minutes in order to dry the indoor unit even though you have
turned off the unit. After energization, X-FAN OFF is defaulted. X-FAN is not available in
AUTO, FAN or HEAT mode.
function: turn on the display's light and press this button again to turn off the display's
light. If the light is turned on,
is displayed. If the light is turned off,
disappears.
Press this button to turn on I FEEL function. The unit automatically adjust temperature
according to the sensed temperature. Press this button again to cancel I FEEL function.
15
/
button
Press this button to achieve the on and off of healthy and scavenging functions in
operation status. Press this button for the first time to start scavenging function; LCD
displays " ". Press the button for the second time to start healthy and scavenging
functions simultaneously; LCD displays " " and " ". Press this button for the third
time to quit healthy and scavenging functions simultaneously. Press the button for the
fourth time to start healthy function; LCD display " ". Press this button again to repeat
the operation above. (This function is applicable to partial of models)
11
Function introduction for combination buttons
Combination of "▲" and " " buttons: About lock
▲
Press "▲" and " " buttons simultaneously to lock or unlock the keypad. If the remote
controller is locked, is displayed. In this case, pressing any button, blinks
three times.
▲
Combination of "MODE" and " " buttons:
About switch between Fahrenheit and centigrade
▲
▲
At unit OFF, press "MODE" and "
" buttons simultaneously to switch between ℃ and ℉.
Combination of "TEMP" and "CLOCK" buttons:
About Energy-saving Function
Press "TEMP" and "CLOCK" simultaneously in COOL mode to start energy-saving function.
Nixie tube on the remote controller displays "SE". Repeat the operation to quit the function.
Combination of "TEMP" and "CLOCK" buttons:
About 8℃ Heating Function
Press "TEMP" and "CLOCK" simultaneously in HEAT mode to start 8℃ Heating Function
Nixie tube on the remote controller displays " " and a selected temperature of "8℃".
(46℉ if Fahrenheit is adopted). Repeat the operation to quit the function.
About Back-lighting Function
The unit lights for 4s when energizing for the first time, and 3s for later press.
12
Operation guide
1. After putting through the power, press "ON/OFF" button on remote controller to
turn on the air conditioner.
2. Press "MODE" button to select your required mode: AUTO, COOL, DRY, FAN,
HEAT.
3. Press "▲" or " " button to set your required temperature. (Temperature can’t
be adjusted under auto mode).
4. Press "FAN" button to set your required fan speed: auto, low, medium and high
speed.
5. Press "SWING" button to select fan blowing angle.
▲
Replacement of batteries in remote controller
battery
1. Press the back side of remote controller marked
the cover of battery box along the arrow direction.
2. Replace two 7# (AAA 1.5V) dry batteries, and
make sure the position of "▲" polar and " " polar
are correct.
3. Reinstall the cover of battery box.
reinstall
remove
Cover of battery box
▲
Note:
● During operation, point the remote control signal sender at the receiving
window on indoor unit.
● The distance between signal sender and receiving window should be no
more than 8m, and there should be no obstacles between them.
or wireless telephone; remote controller should be close to indoor unit during
operation.
● Replace new batteries of the same model when replacement is required.
● When you don’t use remote controller for a long time, please take out the
batteries.
● If the display on remote controller is fuzzy or there’s no display, please
replace batteries.
13
Emergency operation
If remote controller is lost or damaged, please use auxiliary button to turn
on or turn off the air conditioner. The operation in details are as below:
air conditioner. When the air conditioner is turned on, it will operate under
auto mode.
aux. button
panel
WARNING: Use insulated
object to press the auto
button
Clean and Maintenance
WARNING
■ Turn off the air conditioner and disconnect the power before cleaning the air
conditioner to avoid electric shock.
■ Do not wash the air conditioner with water to avoid electric shock.
■ Do not use volatile liquid to clean the air conditioner.
Clean surface of indoor unit
When the surface of indoor unit is dirty, it is recommended to use a soft dry cloth
or wet cloth to wipe it.
NOTICE:
● Do not remove the panel when cleaning it.
14
Clean and Maintenance
1
Open panel
3
Pull out the panel to a certain
● Use dust catcher or water to
the water (below 45℃ ) to clean
it, and then put it in a shady
and cool place to dry.
2
4
panel cover tightly.
WARNING
operation environment, clean frequency can be increased.
15
Clean and Maintenance
NOTICE: Checking before use-season
1. Check whether air inlets and air outlets are blocked.
2. Check whether circuit break, plug and socket are in good condition.
4. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
5. Check whether drainage pipe is damaged.
NOTICE: Checking after use-season
1. Disconnect power supply.
3. Check whether mounting bracket for outdoor unit is damaged or corroded.
If yes, please contact dealer.
Notice for recovery
1. Many packing materials are recyclable materials.
Please dispose them in appropriate recycling unit.
2. If you want to dispose the air conditioner, please contact local dealer or
consultant service center for the correct disposal method.
16
Malfunction analysis
General phenomenon analysis
Please check below items before asking for maintenance. If the malfunction still
can’t be eliminated, please contact local dealer or qualified professionals.
Phenomenon
Check items
Solution
● Whether it's interfered severely ● Pull out the plug. Reinsert
(such as static electricity, stable the plug after about 3min, and
voltage)?
then turn on the unit again.
Indoor unit
can’t receive
remote
controller’s
signal or
remote
controller
has no
action.
● Whether remote controller is
within the signal receiving
range?
● Signal receiving range is 8m.
● Whether there are obstacles?
● Remove obstacles.
● Whether remote controller is
● Select proper angle and point
pointing at the receiving
the remote controller at the rewindow?
ceiving window on indoor unit.
● Is sensitivity of remote contro- ● Check the batteries. If the
power of batteries is too low,
ller low; fuzzy display and no
please replace them.
display?
● Check whether remote cont● No display when operating
roller appears to be damaged.
remote controller?
If yes, replace it.
● Fluorescent lamp in room?
No air
emitted
from
indoor
unit
● Take the remote controller
close to indoor unit.
● Turn off the fluoresent lamp
and then try it again.
● Air inlet or air outlet of indoor
unit is blocked?
● Eliminate obstacles.
● Under heating mode, indoor
temperature is reached to set
temperature?
● After reaching to set temperature, indoor unit will stop blowing out air.
● Heating mode is turned on just ● In order to prevent blowing
now?
out cold air, indoor unit will be
started after delaying for several minutes, which is a normal phenomenon.
17
Malfunction analysis
Phenomenon
Air conditioner can’t
operate
Mist is emitted from
indoor unit’s
air outlet
Set temperature can’t
be adjusted
Cooling
(heating)
effect is
not good.
Check items
Solution
● Power failure?
● Wait until power recovery.
● Is plug loose?
● Reinsert the plug.
● Air switch trips off or fuse is
burnt out?
● Ask professional to replace
air switch or fuse.
● Wiring has malfunction?
● Ask professional to replace it.
● Unit has restarted immediately
● Wait for 3min, and then turn
after stopping operation?
on the unit again.
● Whether the function setting
for remote controller is
correct?
● Reset the function.
● Indoor temperature and humidity is high?
● Because indoor air is cooled
rapidly. After a while, indoor
temperature and humidity will
be decrease and mist will
disappear.
● Unit is operating under auto
mode?
● Temperature can’t be adjusted under auto mode.
Please switch the operation
mode if you need to adjust
temperature.
● Your required temperature
exceeds the set temperature
range?
● Set temperature range:
16℃ ~30℃ .
● Voltage is too low?
● Wait until the voltage
resumes normal.
● Filter is dirty?
● Clean the filter.
● Set temperature is in proper
range?
● Adjust temperature to proper
range.
● Door and window are open?
● Close door and window.
18
Malfunction analysis
Phenomenon
Odours are
emitted
Check items
Solution
● Whether there’s odour source, ● Eliminate the odour source.
such as furniture and cigarette,
● Clean the filter.
etc.
● Whether there’s interference,
such as thunder, wireless
devices, etc.
● Disconnect power, put back
power, and then turn on the
unit again.
Outdoor
unit has
vapor
● Heating mode is turned on?
● During defrosting under heating mode, it may generate
vapor, which is a normal
phenomenon.
“Water
flowing”
noise
● Air conditioner is turned on or
turned off just now?
● The noise is the sound of
refrigerant flowing inside
the unit, which is a normal
phenomenon.
Air conditioner operates
abnormally
Cracking
noise
● Air conditioner is turned on or
turned off just now?
19
● This is the sound of friction
caused by expansion and/or
contraction of panel or other
parts due to the change of
temperature.
Malfunction analysis
Error Code
● When air conditioner status is abnormal, temperature indicator on indoor unit will
ation of error code.
Troubleshooting
Error code
U8
It can be eliminated after restarting the unit. If not, please
H6
It can be eliminated after restarting the unit. If not, please
C5
F1
F2
Note: If there're other error codes, please contact qualified professionals for service.
WARNING
■ When below phenomenon occurs, please turn off air conditioner and disconfor service.
● Power cord is overheating or damaged.
● There’s abnormal sound during operation.
● Circuit break trips off frequently.
● Air conditioner gives off burning smell.
● Indoor unit is leaking.
■ If the air conditioner operates under abnormal conditions, it may cause
20
At least 15cm
Space to the ceiling
Installation dimension diagram
Space to the wall
At least 15cm
At least 15cm
Space to the wall
o
n
tio
uc
tr
bs
Space to the obstruction
ac
Sp
the
At least 250cm
o
et
lea
the
to n
e
ac ctio
Sp stru
st
ob
lea
At cm
30
At least 50cm
At
cm
00
3
st
At least 30cm
Space to th
e wall
ce
a
Sp
t
he
ot
s
ob
n
tio
c
tru
st
A
a
t le
At least 50cm
m
0c
Space to the
obstruction
20
Drainage pipe
21
Tools for installation
1 Level meter
2 Screw driver
3 Impact drill
4 Drill head
5 Pipe expander
6 Torque wrench
7 Open-end wrench
8 Pipe cutter
9 Leakage detector
10 Vacuum pump
11 Pressure meter
12 Universal meter
13 Inner hexagon spanner
Note:
14 Measuring tape
● Please contact the local agent for installation.
● Don't use unqualified power cord.
Selection of installation location
Basic requirement
Installing the unit in the following places maycause malfunction. If it is unavoidable, please consult the local
dealer:
1.The place with strong heat sources,
,
or volatile objects spread in the air.
2.The place with high-frequency
devices (such as welding machine,
medical equipment).
3.The place near coast area.
4.The place with oil or fumes in the air.
5.The place with sulfureted gas.
6.Other places with special circumstances.
7.The appliance shall not be installed in the laundry.
Outdoor unit
Indoor unit
1. There should be no obstruction near air
inlet and air outlet.
2. Select a location where the condensation water can be dispersed easily and
won't affect other people.
3. Select a location which is convenient to
connect the outdoor unit and near the
power socket.
4. Select a location which is out of reach
for children.
5. The location should be able to withstand
the weight of indoor unit and won't increase noise and vibration.
6. The appliance must be installed 2.5m
7. Don't install the indoor unit right above
the electric appliance.
8. Please try your best to keep way from
fluorescent lamp.
will not affect neighborhood.
2. The location should be well ventilated and dry, in which the outdoor unit
won't be exposed directly to sunlight or strong wind.
3. The location should be able to withstand the weight of outdoor unit.
4. Make sure that the installation follows the requirement of installation
dimension diagram.
5. Select a location which is out of reach for children and far away from animals
or plants.If it is unavoidable, please add the fence for safety purpose.
22
Requirements for electric connection
Safety precaution
1. Must follow the electric safety regulations when installing the unit.
air switch.
3. Make sure the power supply matches with the requirement of air conditioner.
Unstable power supply or incorrect wiring or malfunction. Please install proper
power supply cables before using the air conditioner.
4. Properly connect the live wire, neutral wire and grounding wire of power socket.
5. Be sure to cut off the power supply before proceeding any work related to
electricity and safety.
7. If the supply cord is damaged, it must be replaced by the manufacturer, its
8. The temperature of refrigerant circuit will be high, please keep the interconnection cable away from the copper tube.
9. The appliance shall be installed in accordance with national wiring regulations.
Grounding requirement
grounding with specialized grounding device by a professional. Please make
sure it is always grounded effectively, otherwise it may cause electric shock.
2. The yellow-green wire in air conditioner is grounding wire, which can't be used
for other purposes.
3. The grounding resistance should comply with national electric safety regulations.
4. The appliance must be positioned so that the plug is accessible.
5. An all-pole disconnection switch having a contact separation of at least 3mm in
6. Including an air switch with suitable capacity, please note the following table. Air
switch should be included magnet buckle and heating buckle function, it can
protect the circuit-short and overload. (Caution: please do not use the fuse only
for protect the circuit)
Air-conditioner
Air switch capacity
09K
10A
09K(115V)、12K
16A
12K(115V)
25A
23
Installation of indoor unit
Step one: choosing installation location
rm it with the client.
Step two: install wall-mounting frame
1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the
plastic expansion particles in the holes.
3. Fix the wall-mounting frame on the wall with tapping screws (ST4.2X25TA) and
.
Step three: open piping hole
1. Choose the position of piping hole according to the direction of outlet pipe. The
position of piping hole should be a little lower than the wall-mounted frame,
shown as below.
Wall
Space
to the
wall
above
150mm
Mark in the middle of it
Level meter
Wall
Space
to the
wall
above
150mm
Right
Φ55mm
Rear piping hole
Left
Φ55mm
Rear piping hole
2. Open a piping hole with the diameter of Φ55 on the selected outlet pipe
position.In order to drain smoothly, slant the piping hole on the wall slightly
downward to the outdoor side with the gradient of 5-10°.
24
Installation of indoor unit
Indoor
outdoor
Note:
● Pay attention to dust prevention and
take relevant safety measures when
opening the hole.
● The plastic expansion particles are
not provided and should be bought
locally.
Φ55
5-10
Step four: outlet pipe
2. When select leading out the pipe
from left or right, please cut off the
corresponding hole on the bottom
case.
1. The pipe can be led out in the
direction of right, rear right, left or
rear left.
left
right
left
rear right
rear left
right
cut off
the hole
1. Aim the pipe joint at the corresponding
bellmouth.
pipe joint
union nut
pipe
2. Pretightening the union nut with hand.
3. Adjust the torque force by referring to the following sheet. Place the open-end
wrench on the pipe joint and place the torque wrench on the union nut. Tighten
the union nut with torque wrench.
25
Installation of indoor unit
open-end
wrench
union nut
torque wrench
pipe
Hex nut diameter Tightening torque (N.m)
Φ6
15~20
Φ 9.52
30~40
Φ 12
45~55
Φ 16
60~65
Φ 19
70~75
indoor pipe
4. Wrap the indoor pipe and joint of connection pipe with insulating pipe, and
then wrap it with tape.
insulating pipe
Step six: install drain hose
1. Connect the drain hose to the outlet pipe of
indoor unit.
2. Bind the joint with tape.
outlet pipe
drain hose
drain hose
outlet
pipe
tape
drain hose
Note:
● Add insulating pipe in the indoor
drain hose in order to prevent
condensation.
● The plastic expansion particles are
not provided.
insulating pipe
Step seven: connect wire of indoor unit
panel
screw
1. Open the panel, remove the screw
on the wiring cover and then take
down the cover.
wiring cover
26
Installation of indoor unit
2. Make the power connection wire go
through the cable-cross hole at the back
of indoor unit and then pull it out from
the front side.
cable-cross
hole
power connection
wire
3. Remove the wire clip; connect the power
connection wire to the wiring terminal
according to the color; tighten the screw
with wire clip.
09、12K Cool only type:
N(1)
12K Heat pump type:
2
N(1)
blue black yellowgreen
yellowgreen
outdoor unit connection
2
4
5
blue black violet orange
Outdoor unit connection
Note: the wiring board is for reference only, please refer to the actual one.
4. Put wiring cover back and then tighten the screw.
5. Close the panel.
Note:
● All wires of indoor unit and outdoor unit should be connected by a professional.
for a new one. Avoid extending the wire by yourself.
installation.
● For the air conditioner without plug, an air switch must be installed in the line.
The air switch should be all-pole parting and the contact parting distance should
be more than 3mm.
27
Installation of indoor unit
Step eight: bind up pipe
1. Bind up the connection pipe, power
cord and drain hose with the band.
indoor unit
gas
pipe
connection pipe
drain hose
band
indoor and
outdoor power cord
indoor power cord
liquid pipe
band
3. Bind them evenly.
4. The liquid pipe and gas pipe should
be bound separately at the end.
drain hose
2. Reserve a certain length of drain
hose and power cord for installation
when binding them. When binding to
a certain degree, separate the indoor
power and then separate the drain
hose.
Note:
● The power cord and control wire
can't be crossed or winding.
● The drain hose should be bound
at the bottom.
Step nine: hang the indoor unit
1. Put the bound pipes in the wall pipe and then make them pass through the wall
hole.
2. Hang the indoor unit on the wall-mounting frame.
3. Stuff the gap between pipes and wall hole with sealing gum.
4. Fix the wall pipe.
5. Check if the indoor unit is installed firmly and closed to the wall.
indoor
wall pipe
upper hook
outdoor
sealing gum
lower hook of
wall-mounting frame
Note:
● Do not bend the drain hose too excessively in order to prevent blocking.
28
Installation of outdoor unit
(select it according to the actual installation situation)
1. Select installation location according to the house structure.
2. Fix the support of outdoor unit on the selected location with expansion screws.
Note:
● Take sufficient protective measures when
installing the outdoor unit.
● Make sure the support can withstand at least
four times of the unit weight.
● The outdoor unit should be installed at least
3cm above the floor in order to install drain
joint.
● For the unit with cooling capacity of 2300W
~5000W, 6 expansion screws are needed;
for the unit with cooling capacity of 6000W
~8000W, 8 expansion screws are needed;
for the unit with cooling capacity of 10000W at least 3cm above the floor
~16000W, 10 expansion screws are needed.
Step two: install drain joint
(Only for cooling and heating
unit)
1. Place the outdoor unit on the
support.
2. Fix the foot holes of outdoor unit
with bolts.
1. Connect the outdoor drain joint into
the hole on the chassis, as shown in
the picture below.
2. Connect the drain hose into the drain
vent.
drain vent
Drain hose
foot holes
foot holes
chassis
outdoor drain joint
29
Installation of outdoor unit
Step four: connect indoor and outdoor pipes
1. Remove the screw on the right handle of outdoor unit and then remove
the handle.
3. Pretightening the union nut with
hand.
pipe joint
screw
union nut
handle
2. Remove the screw cap of valve and
aim the pipe joint at the bellmouth of
pipe.
4. Tighten the union nut with torque
wrench by referring to the sheet
below.
torque
Hex nut diameter Tightening
(N.m)
Φ6
15~20
Φ 9.52
30~40
Φ 12
45~55
Φ 16
60~65
Φ 19
70~75
liquid pipe
liquid
valve
gas pipe
gas valve
1. Remove the wire clip; connect the power connection wire and signal control
wire (only for cooling and heating unit) to the wiring terminal according to the
09、12K Cool only type:
N(1)
12K Heat pump type:
2
N(1)
blue black yellow(brown) green
Indoor unit connection
yellowgreen
4
5
Indoor unit connection
Note: the wiring board is for reference only, please refer to the actual one.
30
2
blue black violet orange
Installation of outdoor unit
2. Fix the power connection wire and signal control wire with wire clip (only for
cooling and heating unit).
Note:
● Never cut the power connection wire to prolong or shorten the distance.
Step six: neaten the pipes
1. The pipes should be placed along the wall,
bent reasonably and hidden possibly. Min.
semidiameter of bending the pipe is 10cm.
2. If the outdoor unit is higher than the wall
hole, you must set a U-shaped curve in the
pipe before pipe goes into the room, in
order to prevent rain from getting into the
room.
wall
U-shaped curve
drain hose
Note:
● The through-wal height of drain hose
shouldn't be higher than the outlet
pipe hole of indoor unit.
● Slant the drain hose slightly downwards. The drain hose can't be
the drain hose
can't raise
upwards.
The drain hose can't be fluctuant
● The water outlet can't be placed
in water in order to drain smoothly.
The drain hose
can't be fluctuant
The water outlet
can't be placed
in water
31
The water
outlet can't be
fluctuant
Vacuum pumping
Use vacuum pump
1. Remove the valve caps on
liquid valve
the liquid valve and gas
piezometer
Lo
Hi
valve and the nut of refrigas valve
gerant charging vent.
valve cap
2. Connect the charging ho- refrigerant charging
vent
se of piezometer to the
refrigerant charging vent
nut of refrigerant
of gas valve and then co- charging vent
nnect the other charging
vacuum pump
hose to the vacuum pump.
3. Open the piezometer cominner hexagon
pletely and operate for
spanner
10-15min to check if the
pressure of piezometer remains in -0.1MPa.
close
4. Close the vacuum pump
open
and maintain this status for
1-2min to check if the pressure of piezometer remains
in -0.1MPa. If the pressure decreases, there may be leakage.
5. Remove the piezometer, open the valve core of liquid valve and gas valve
completely with inner hexagon spanner.
6. Tighten the screw caps of valves and refrigerant charging vent.
Leakage detection
1. With leakage detector:
Check if there is leakage with leakage detector.
2. With soap water:
If leakage detector is not available, please use soap water for leakage detection.
Apply soap water at the suspected position and keep the soap water for more
than 3min. If there are air bubbles coming out of this position, there's a leakage.
32
Check after installation
● Check according to the following requirement after finishing installation.
Items to be checked
Possible malfunction
Has the unit been installed firmly?
The unit may drop, shake or emit noise.
Have you done the refrigerant leakage
test?
It may cause insufficient cooling
(heating) capacity.
Is heat insulation of pipeline sufficient?
It may cause condensation and water
dripping.
Is water drained well?
It may cause condensation and water
dripping.
Is the voltage of power supply according to the voltage marked on the
nameplate?
It may cause malfunction or damaging
the parts.
Is electric wiring and pipeline installed
correctly?
It may cause malfunction or damaging
the parts.
Is the unit grounded securely?
It may cause electric leakage.
Does the power cord follow the specification?
It may cause malfunction or damaging
the parts.
Is there any obstruction in the air inlet
and outlet?
It may cause insufficient cooling
(heating) capacity.
The dust and sundries caused during
installation are removed?
It may cause malfunction or damaging
the parts.
The gas valve and liquid valve of
connection pipe are open completely?
It may cause insufficient cooling
(heating) capacity.
Test operation
1. Preparation of test operation
● The client approves the air conditioner.
● Specify the important notes for air conditioner to the client.
2. Method of test operation
● Put through the power, press ON/OFF button on the remote controller to start
operation.
● Press MODE button to select AUTO, COOL, DRY, FAN and HEAT to check
whether the operation is normal or not.
● If the ambient temperature is lower than 16℃ , the air conditioner can’t
start cooling.
33
Configuration of connection pipe
1. Standard length of connection pipe
● 5m, 7.5m, 8m.
2. Min. length of connection pipe is 3m.
3. Max. length of connection pipe and max. high difference.
Cooling
capacity
Max length
Max height
of connecdifference
tion pipe
Cooling
capacity
Max length
Max height
of connecdifference
tion pipe
5000Btu/h
(1465W)
15
5
24000Btu/h
(7032W)
25
10
7000Btu/h
(2051W)
15
5
28000Btu/h
(8204W)
30
10
9000Btu/h
(2637W)
15
5
36000Btu/h
(10548W)
30
20
12000Btu/h
(3516W)
20
10
42000Btu/h
(12306W)
30
20
18000Btu/h
(5274W)
25
10
48000Btu/h
(14064W)
30
20
4. The additional refrigerant oil and refrigerant charging required after prolonging
connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of
standard length, you should add 5ml of refrigerant oil for each additional 5m
of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis
of liquid pipe):
Additional refrigerant charging amount = prolonged length of liquid pipe ×
additional refrigerant charging amount per meter
● Basing on the length of standard pipe, add refrigerant according to the
requirement as shown in the table. The additional refrigerant charging amount
per meter is different according to the diameter of liquid pipe. See the
following sheet.
34
Configuration of connection pipe
Additional refrigerant charging amount for R22, R407C, R410A and R134a
Diameter of connection pipe
Outdoor unit throttle
Liquid pipe(mm)
Gas pipe(mm)
Φ6
Φ9.52 or Φ12
15
20
Φ6 or Φ9.52
Φ16 or Φ19
15
50
Φ12
Φ19 or Φ22.2
30
120
Φ16
Φ25.4 or Φ31.8
60
120
Φ19
_
250
250
Φ22.2
_
350
350
Cooling only(g/m) Cooling and heating(g/m)
35
Pipe expanding method
Note:
Improper pipe expanding is the main cause of refrigerant leakage. Please expand
the pipe according to the following steps:
A: Cut the pipe
● Confirm the pipe length according to
the distance of indoor unit and
outdoor unit.
● Cut the required pipe with pipe cutter.
E: Expand the port
● Expand the port with expander.
hard
mold
expander
pipe
pipe
pipe cutter
leaning
uneven
Note:
● "A" is different according to the
diameter, please refer to the sheet
below:
burr
B: Remove the burrs
● Remove the burrs with shaper and
prevent the burrs from getting into
the pipe.
pipe
shaper
downwards
A(mm)
Outer diameter
(mm)
Max
Min
Φ6 - 6.35(1/4")
1.3
0.7
Φ9.52(3/8")
1.6
1.0
Φ12-12.7(1/2")
1.8
1.0
Φ15.8-16(5/8")
2.4
2.2
F: Inspection
● Check the quality of expanding port.
If there is any blemish, expand the
port again according to the steps
above.
C: Put on suitable insulating pipe
D: Put on the union nut
● Remove the union nut on the indoor
connection pipe and outdoor valve;
install the union nut on the pipe.
smooth surface
improper expanding
union pipe
leaning
pipe
the length is equal
36
damaged
surface
crack
uneven
thickness
Split Air Conditioner
OWNER'S MANUAL
GREE AIR CONDITIONERS
Model A:
GWHD09ABNK3A1B
GWHD12ABNK3A1B
Model B:
GWHD09ABNK3A1C
GWHD12ABNK3A1C
Thank you for choosing GREE air conditioner for correct operation, please
read this owner's manual carefully before operating the unit and keeps
66129918981
it carefully for consultation.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement