null  User manual
Care & Maintenance
3M Adflo Powered Air Respirator
™
™
To optimize the lifetime of your welding equipment and avoid the additional cost of replacement, regular
maintenance is important. Replace all damaged parts immediatelly to ensure correct levels of protection.
Before use
After use
• Battery. Ensure that it’s adequately charged and fitted
correctly.
• Turbo unit. Inspect the unit for damage and that it’s
firmly fixed to the belt. Ensure filters are correctly fitted.
• Breathing tube. Inspect the tube and connections
to ensure they are free from splits and holes.
Replace if damaged, deformed or leaking any air.
To extend the life of the breathing tube, use a tube cover
or the heavy-duty rubber breathing tube.
• Air flow check. Fit the breathing tube to the turbo unit
and attach the airflow meter in the other end of the tube
and switch on the turbo. If the ball does not rise above
the line, continue fault finding.
• Alarm check. Cover the air outlet of the airflow
meter with your hand until an audible warning is heard
and the red indicator illuminates. Remove your hand.
The alarm should now stop.
• Clean the equipment. Wipe the turbo with a moist tissue or
cloth. If you suspect that the inside of the breathing tube is dirty,
it must be changed.
DO NOT rinse, immerse in water or clean with solvents.
DO NOT attempt to remove contamination on filters using for example
compressed air as this will damage the filters and the warranty will
be invalidated.
• Replace damaged parts. Replace all damaged parts to guarantee
the function of the respirator. Worn out components should be
disposed of according to local regulations.
• Spark arrestor. Replace if deformed and no longer fitting well.
• Prefilter. Replace if it’s too dirty, to extend the life of the particle
filter, saving money while also helping the battery run-time.
• Particle filter. Check the battery indicators position and replace if
the red LED is lit. Otherwise, replace whenever the battery operating
time becomes too short, or when “fully loaded” filter triggers low
airflow alarm.
• Gas filter. Replace the gas filter according to your work place
requirements. Do not wait until you can sense odours or smells.
• Odour filter. Replace any time you smell unpleasant odours.
Odour filter is not required if gas filter is used.
• Storage. Put the battery/turbo unit on charging after each use. When
stored, recharge every six months. Store the unit in a dry, clean area
away from direct sunlight, high temperatures and solvents. For example use the Adflo storage bag.
83 40 08
83 40 17
83 40 18
83 71 10
83 71 20
83 50 20
83 70 00
83 50 05
83 20 00
83 37 06
80 60 20
83 80 31
83 60 00
83 60 10 83 70 10
83 80 20
83 76 30
83 40 16
83 72 42
83 50 00
83 77 10
83 31 11
83 72 42
83 75 42
83 76 31
83 73 01
83 77 30
Part No Description
Part No Description
Part No Description
Part No Description
Part No Description
Part No Description
83 77 10 Adflo respirator with self-adjusting breathing tube QRS,
airflow indicator, prefilter, spark arrestor, particle filter and
battery.
83 77 30 Adflo respirator with self-adjusting breathing tube QRS,
breathing tube, airflow indicator, prefilter, spark arrestor,
particle filter, battery, belt and charger.
83 77 31 Adflo respirator as in 83 77 30, but with heavy-duty battery.
80 60 20 Backpack.
83 20 00 Turbo assembly, without filter, without filter cover.
83 31 01 Battery charger for NiMh batteries.
83 31 11 Battery charger for Li-ion batteries.
83 37 06 Battery charging stand 6-position.
83 40 08 Breathing tube with silencer, non-QRS.
83 40 16 Breathing tube, self-adjusting (52,5 to 85 cm), with QRS connection.
83 40 17 Breathing tube, heavy-duty rubber, with QRS connection.
83 40 18 Flame resistant breathing tube cover.
83 50 00 Belt.
83 50 05 Front part, belt.
83 50 10 Quick connection for belt (not shown).
83 50 20 Braces.
83 60 00 Spark arrestor.
83 60 10 Prefilter, pkg of 5.
83 60 80 Prefilter, pkg of 80.
83 70 00 Storage bag.
83 70 10 Particle filter P SL.
83 70 20 Particle filter P SL, pkg of 20.
83 70 80 Particle filter P SL, pkg of 80.
83 71 10 Odour filter.
83 71 20 Odour filter replacement pad.
83 72 42 Gas filter A1B1E1.
83 73 01 Gas filter kit: A1B1E1 filter and Li-ion Heavy-Duty battery.
83 75 42 Gas filter A2.
83 76 20 NiMh Battery (standard).
83 76 21 NiMh Battery Heavy-Duty.
83 76 30 Li-ion Battery (standard).
83 76 31 Li-ion Battery Heavy-Duty.
83 80 20 Airflow indicator.
83 80 31 Filter cover, black.
www.speedglas.com
Scan this QR-code to see
videos and learn more about
care and maintenance of your
Speedglas welding helmet
www.facebook.com/SpeedglasGlobal
www.youtube.com/3MSpeedglas
www.Instagram.com/3MSpeedglas
Further information and advice
To request a quote or place an order for spare parts, please contact your 3M approved distributor. Please note that higher than normal levels
of pollutants, heat and sparks will require more frequent replacement of components. If you require additional guidance, please check the care
and maintenance videos on our YouTube Channel (3M Speedglas) or contact your local 3M representative.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement