Horton Automatics Series 2000 Linear Drive Slide Door Installation instructions
The Series 2000 Linear Drive Slide Door is a power-operated door designed for commercial or industrial applications. It is controlled by a C2150 microprocessor and features automatic locking, safety beams, and presence detection. The door can be customized for various configurations and sizes, utilizing different types of panels: both fixed and swing, as well as various types of bottom guides.
Advertisement
Advertisement
G200, OCT 200 5
Series 2000
Linear Drive Slide Door
INSTALLATION INSTRUCTIONS
To be used with H201 C2150 Ver.1 Control Setup Instructions
CONTENTS
1. Instructions to installer................................................................. G200.1
2. General requirements.................................................................. G200.1
3. Installing frame.............................................................................G200.2
4. Installing floor guides................................................................... G200.2
5. Installing side panels....................................................................G200.3
6. Installing slide panels................................................................... G200.4
7. Typical glazing and squaring........................................................G200.5
8. Standard locking.......................................................................... G200.5
9. Automatic locking (optional)......................................................... G200.6
10. Activating devices........................................................................ G200.6
11. Motion Sensor Prep..................................................................... G200.6
12. Safety considerations...................................................................G200.7
13. Decal application..........................................................................G200.7
14. Mechanical parts - series 2003.................................................... G200.8
15. C2150 microprocessor control..................................................... G200.9
1.069d1
G200.1
SERIES 2000 ELECTRIC SLIDING DOOR
INSTALLATION INSTRUCTIONS
1. INSTRUCTIONS TO INSTALLER
•This door is to be installed by a trained and experienced installer with knowledge of local codes and ANSI A156.10
standards for power operated doors.
•To ensure safe and proper operation, the door must be installed and adjusted to conform to Horton Automatics recommendations, all code requirements and ANSI A156.10.
•If there are any questions about these instructions, call Horton Automatics Technical Assistance.
INFORMATION TO BE PROVIDED BY THE DISTRIBUTOR TO THE OWNER
•After installation instruct the owner on the safe operation of the door.
•Present the Owners Manual M300 and explain how to perform the daily safety check.
•Location of power on / off switch.
•Necessary warnings not covered in these general instructions.
•Date equipment shipped from Horton Automatics.
•Date equipment placed in service.
•Horton Automatics' invoice number for warranty reference.
•Equipment type.
•Accessories included.
•Phone number to call regarding problems or request for service.
•Give caution to owner: if a potentially hazardous situation is suspected, the door should be taken out of automatic service untill a professional inspection is made and the problem is corrected.
2. GENERAL REQUIREMENTS
•Power: 120 VAC, 60Hz, 15 Amp service (in conduit) to the "J" box inside the header of each unit.
•Non North American voltages can be 240 VAC, if so be sure the operator has a 240VAC power supply.
•Power may be brought in through the top of the jamb on perimeter mount units or in through the back of surface mount units.
•For remote switch locations, routing of low voltage class II wiring (in conduit) to the operator controls will be required.
•Remote switch locations should be predetermined and wired before installation begins.
•Opening size should be 1/4" taller and 1/2" wider than the unit / frame.
•The opening must be plumb and level, including the threshold area.
•Door panels may be glazed before or after installation.
POWER INPUT LOCATIONS
Faceplate in
UNIT WIDTH
010
O-X X-O
Optional Transom
UNSUPPORTED WIDTH
010 & 110 UNITS
UNSUPPORTED WIDTH OF 310 UNITS
110
310
O-SX
Face Plate
SX-O
Faceplate out
Faceplate in
SX-SO SO-SX
EXTERIOR
LOAD LIMITS & SIZES OF UNSUPPORTED TRANSOMS
Unsupported Width Allowable Transom Weight up to 8'
600 Lb.* up to 10' up to 12'
250 Lb.
100 Lb.
Supporting dead weight on headers longer than
12' is not recommended.
*For loads greater than 250 lb. 1/4" screws instead of
#10 screws should be used secure the header to the jamb.
1.070d1
3. INSTALLING FRAME
G200.2
Take care that the frame is not racked. Wood shingles will be needed to shim the unit. All the fasteners shown below are provided with each unit. If these are inappropriate, alternate fasteners are shown in the fastener chart. Route power supply wiring and low voltage wiring.
Power supply
5th Step
Secure the header with
#14 HHSMS every 36"(914) to 48"(1219).
6th Step
Drill #7 (.201") holes and secure jamb with #10 x
2 1/2" PHSMS.
Last Step
Install pocket filler.
Snap in short piece, slide up into header - hold in place
& snap in 2nd piece.
4th Step
Level plumb & shim.
Shim bottom of jambs
& track to be level with the highest point
NOTE:
Be sure face plate is on the correct side for the type unit being installed.
Face plate side
3rd Step
Tilt unit up into place.
2nd Step
Secure jambs to header with
#10 FHMS into jamb clips.
1st Step
Remove the face plate and Place the header and jambs on floor to assemble.
NOTE: Protect finish from damage by placing unit on saw horses or protective surface.
Exterior view
310 unit
Jamb clips
FASTENER CHART
FASTENER
SIZE / TYPE
#6 SMS &
#6-32 MS
CLEAR
DRILL / C'SINK
#25(.149) &
#6 c'sink
SHEET METAL
DRILL HOLE
#31(.120)
#10 SMS&
#10-24 MS
#14 SMS &
#1/4-20 MS
#7(.201) &
#10 c'sink
#F(.257) &
#14 c'sink
#21(.159)
3/16(.187)
TAP
DRILL
TAP
SIZE
#36(.106)
#6-32
MASONRY
#25(.149)
#10-24
#7(.149) 1/4-20
Drill 1/4"(.25) & use
C1423 green anchor
Drill 5/16"(.312) & use
C1424 blue anchor
4. INSTALLING FLOOR GUIDES
Bottom guides will vary with the unit type. The 3 basic types are shown below. The C315 / C386-1 filler is used with threshold only.
Guide must be level
C330-1
Secure with fasteners provided.
See chart for drill sizes.
Bottom of guide must be even with bottom of jamb
C386-1Used with threshold only
Pivot Area
C330-1
C2873
C315
SERIES 110 SX-O
SERIES 010X-O
NOTE:
ALL VIEWEDFROM EXTERIOR SIDE.
SERIES 310 SX-SO
1.071d
G200.3
5. INSTALLING SIDE PANELS
2 types of side panels are shown "O" fixed and "SO" swing panel. If panels are to be glazed before installation see section 7.
Panels come assembled and prewired from the factory, unless side panels are extra large.
TYPE 010 OR 110 "O" PANEL
1st Step
Position the "O" panel, as shown, in the C330-1 bottom guide about 1" from the jamb to clear security stud.
2nd Step
Connect safety wiring harness from door panel to harness in header. Make connection inside door panel. Place wire in the notch before tilting panel into position.
TYPE 310 "SO" PANEL
2nd Step
Place "SO" panel in open position & rotate closer arm under header. Secure "SO" closer with #10 screws.
Security stud
"SO" Cutoff switchin header
Closer arm
Ball catch
"SO" Cutoff magnet
3rd Step
Slide panel against the jamb
& match drill with #21
(.159) bit thru existing holes into top rail. Secure with #10 screws.
NOTE: there will be a small space between top of panel and bottom of header.
CAUTION:
Closer arm is spring loaded.
Take precautions to avoid injury.
Connect prewired safety beam door harness to harness in the header. Take care not to damage wires as door is put into place.
Safety beams
110
EXTERIOR
010
INTERIOR
"O" Panel
C330-1
Ball catch
Use C386-1 /C315 only with threshold applications.
"SO" Panel
1st Step
Install weather strip before mounting panel.
EXTERIOR
VIEW
2nd Step
Place "SO" Panel on bottom pivot.
G200.4
6. INSTALLING SLIDE PANELS
3 types of slide panels are shown 010, 110 & 310. If panels are to be glazed before installation see section 7.
Height adjustment
2nd Step
Connect the hanger to the wheel carriage.
Adjust height as required
NOTE:
Always loosen height adjustment screw before installing or removing carriage bolts.
Height adjustment screws should not be used to raise or lower the door - only to hold it in place.
Install threshold after all panels are in place.
TYPE 010
"X" PANEL
2nd Step
Connect the breakout to the wheel carriage.
Adjust height as required
"X"
Panel
1st Step
Remove end cap.
Slide bottom guide into track.
The panel may need to be angled to start pins into the guide.
"O"
Panel
End cap
Adjust interlocks to line up vertical rails.
2nd Step
Connect the breakout to the wheel carriage.
Adjust height as required
TYPE 110
"SX" PANEL
"SX"
Panel
1st Step
Remove end cap.
Slide bottom guide into track.
The panel may need to be angled to start pins into the guide.
Set flush with back of rail.
TYPE 310
"SX" PANEL
"SX"
Panel
End cap
1st Step
Place guide pin in the track.
The door panel may need to be angled to start.
UNITS ARE VIEWED FROM THE EXTERIOR SIDE
"SO"
Panel
1.073d
G200.5
7. TYPICAL GLAZING AND SQUARING ( SX-SO single slide shown)
Door panels may be glazed laying down flat or installed in the frame. The latter method is referred to below.
Torsion bar
2nd Step
Use the leveling screw to bring the panels to exact square.
The "SX" & "SO" are spring loaded and will not stay in open position with out being held.
*
*
*
*
*
*
*
*
1st Step
Always glaze the "SX" panel with the torsion bar in the broken-out position.
Optional
Muntin
NOTE:
Do not remove glazing blocks from door panels or glass
breakage will occur when the leveling screw is adjusted.
*
*
*
*
*
*
*
*
*
Glazing block locations
"SX"
Panel
"SO"
Panel
8. STANDARD LOCKING
A lock cylinder is included with door. UL requires that the inside of the lock be equipped with a thumbturn. Local codes may vary.
STANDARD FACTORY
INSTALLED LOCK IN
THE SX BREAKOUT
OR
IN THE FLOOR
1 5/32" (29) Key Cylinder.
Use same diameter for replacement cylinders.
Locks into adjacent door panel orjamb
Cylinder height
Drop bolt application
Use C of bolt to hole
Rod bolt length approx. 7"less than cylinder height
1.074d1
G200.6
9. AUTOMATIC LOCKING (OPTIONAL)
The Fail Safe and Fail Secure Autolocks will only inhibit the slide action of the door not the "swing" or breakout action. See section 8 for standard locking. Autolocks are installed at the factory. Retrofit units will be supplied with instructions.
GENERAL AUTOLOCK OPERATION
C2176-5 fail secure
To CN4 on the
C2150 control
-Open signal is received by control (C2150)
-Unlock signal is sent to Autolock
-Solenoid retracts lockbolt
-Door opens and closes
-Solenoid extends the lockbolt when door is fully closed and the keeper is in locked position
-Door (slide motion only) is locked
C789 Ke eper
LINEAR DRIVE AUTOLOCK
C2176-5 Fail secure (if power fails the door will remain locked)
C2176-5 Fail safe (if power fails the door will unlock)
Soleniod
C2196-5 fail safe
Latch Bo lt
10. ACTIVATING DEVICES
-Activating switches must be located where door operation may be observed by the person actuating it.
-ANSI standard requires a motion detector be placed on each side of the door and be active while the door is open
(except the last 6" 150mm of closing). The detector pattern may be reduced to 24"(610) on the control side for one-way traffic.
-Mount sensors on the door header or above at a height of 7ft (2134) to 8ft (2438) from the floor.Sensitivity and detection area may not meet ANSI standards if detector is placed higher.
-Walk test the pattern from various angles and speeds.
-Adjust the sensitivity and pattern of the motion sensor as per ANSI A156.10 See drawing below for pattern and location.
See instructions supplied with the sensor.
NOTE:Never decrease the sensitivity or pattern so it will not detect slow moving traffic.
-The motion detector time delay should be set to a minimum of two seconds cumulative with C2150 control before the door begins to close. Three seconds or more is recommended by Horton Automatics.
11. MOTION SENSOR PREP
1st Step
Drill hole in faceplate for wiring and mount motion sensor with sheet metal screws.No more than
7ft to 8ft above the floor.
Drilling template is provided with motion detector. Route wiring to avoid moving parts.
2nd Step
Route wiring through faceplate and wire way to C2150 control
2 9/16" Use caution when drilling in this area if autolock is installed
Safety beams
48"
24"
Presence
Detection
43"
Minimum
5" Max.
30"
8"
NOTE:
Dimensions taken from face of sliding door each side.
Clear Do or openin g width
1.075d4
G200.7
12. SAFETY CONSIDERATIONS
To comply with Underwriters' Laboratories Safety Requirements (UL 325),ANSI A156.10 and pedestrian safety, horizontal sliding doors must be adjusted within the following requirements and guidelines.
CLOSING SPEED
- At no time should the door close faster than 1ft per second or close completely in less than 3 seconds for door panels weighing up to and including 160 lbs 73kg.
CLOSING FORCE
-The force required to stop the door should not exceed 30 foot pounds (133N).
REVERSING
- The reversing circuit of the C2150 must be adjusted to reverse when a maximum force of 28 foot pounds (38N) is exerted to prevent the door from closing.
TIME DELAY
- The time before closing should never be less than 2 seconds. 3 seconds or more (after activating zone is clear) is recommended by Horton Automatics.
For set-up and trouble-shooting
SEE HORTON PUBLICATION H201 FIELD QUICK START INSTRUCTIONS.
NOTE: After adjustments are completed be sure the faceplate is secured with screws into the support brackets.
THRESHOLD PROTECTION
- All sliding doors should be installed with presence detection on each side of sliding doors in addition to dual safety beams.
- Motion detectors must be set up as per section 10 on previous page.
13. DECAL APPLICATION
C7280
Place on entry side of slide panels on doors using pushbutton entry
To meet knowing act
ANSI standard.
C1630-2
For 2-way traffic place one on each sliding panel.
For 1-way traffic use C1631-3
(sent with unit)
AUTOMATIC
CAUTION
DOOR
ACTIVATE SWITCH
TO OPERATE
HORTON AUTOMATICS
AUTOMATIC DOOR
KEEP MOVING
HORTON AUTOMATICS
C1631-3
For 1-way traffic place the side shown toward control side of door.
DO NOT
ENTER
ONE-WAY
AUTOMATIC DOOR
HORTON AUTOMATICS
C1690-1
Daily safety check.
Place near on / off switch at eye level.
C1634
Place on sidelites.
(sent with unit)
STAND CLEAR
AUTOMATIC SLIDING
DOOR
HORTON AUTOMATICS
Locate decals on the center line of each panel at elevation shown.
STAND CLEAR
AUTOMATIC SLIDING
DOOR
HORTON AUTOMATICS
STAND CLEAR
AUTOMATIC SLIDING
DOOR
HORTON AUTOMATICS
HORTON AUTOMATICS HORTON AUTOMATICS
58"(1473)
± 5"(127)
48"(1219)
C1682
Place on exit side of breakout panels.
(sent with unit)
IN EMERGENCY PUSH TO OPEN
1.076d
C265
C437
C437
C437
C946
C264
C598-1
C270-1
For Field Painted
"K.D." Units Only
C2145-2
RH
C2145-2 LH
(Not Shown)
C944
C266R
C437
C291-1
C437
C945
C380-1
C128
C587
C2145-1
C543
C563
C2136-1
C437
C467A
C1472 Wire
C526 (Right)
C2117-2
(2) C887 1/4-20 FHMS &
(2) C404 1/4-20 Kep Nut
(2) C2118 Washer
Required For Mounting
C2248
C483
C482
C2103
C2152
C404
C2126
C546
C643
C483
C2102-1
C2134-1
C2102-2
(4)C483
C2128
C528
C527(Left)
C4011-1
(4)C643
C2180-2
(2)C546
(2)C483
C2151-1
C404
C546
C483
C2118
C404
C2118
C2136-1
C546
C643
C887
(2)C804
(2)C406
C2249
C404
(3)C483
C3992
C2246
C2135-1
C804
C406
C2101-1
C804
C401
C546
C406
C404
C876-1
C826-1
(2 1/8")
C837-1
Short Bumper
C875-1
C828 (1 3/8")
C841-1
C812-2
C815
C404
C483
C405L
C404
C651
C576
C690
C402
C401
C406
C404
C483
C406
C643
C817
(3)C483
C2246
C2135-1
C2249
C2146-1
C2148
C814-1
C406
C419-1
C546
C402 C406
C419-1
C817
C409
O-X-X-O
C483
C402
C406
C404
C404
C409
C404
C7076
C2131-1
C2129-1
C2230
(2)C406
C4062
C2130-1
C404
(2)C804
C468
C542
C474-1
C2143-2
(2)C404
(2) C2118
(2)C887
C401
C2129-1
C483
C2137-1
C543
C564
C8
C407
(C408 Opp. Hand)
(3)C404
14.MECHNICAL PARTS - SERIES 2000
1.077d1
C483
C405L
C3959
24" Harness
NOTE:
See H201 C2150 Quick start instructions for complete set up, wiring diagrams and trouble shooting.
C3955
Power Supply
Indicator
LED 's
C2150
Control
Code display
D1
CN2
S1
CN5
1
S2 S3 S4
CN4
CN11
CN7
R10
K3
K1
K2
J1
CN8
To
Autolock
CN4
C3913
Terminal
Strip
16
CN11
A.C. Power in
C3992 motor harness
To Motor
C2155-4
Micro switch harness
CN2
C3951 switch
CN1
F1
F2
F3
CN3.
All Fuses are
5x20 mm Type "T"
Rated 3.15Amp
1.078d2
15. C2150 MICROPROCESSOR CONTROL
A U T O M A T I C S
4242 Baldwin Boulevard
Corpus Christi,
Texas, U.S.A. 78405-3399
Tel: 800-531-3111, 361-888-5591
Horton Automatics, Ltd.
Unit A, Hortonwood 31
Telford, Shropshire, England TF1-4GS
Tel: 01952 670169, Fax: 0192 670181
Fax: 800-531-3108, 361-888-6510
Internet: http://www.hortondoors.com
International Tel: ++44-1952-670169
International Fax: ++44-1952-670181
A Division of Overhead Door Corporation, A Sanwa Shutter Company
Form G200, OCT 200 5
, printed in U.S.A.
Horton Automatics reserves the right to improve the product and change its specifications without notice.

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Linear Drive Motor
- Automatic Locking (Optional)
- Motion Sensor Activation
- Customizable Panels
- Detailed Installation Instructions