SFP STEREO FM TO FM RADIO PROCESSOR

SFP STEREO FM TO FM RADIO PROCESSOR
HEAD END
I
RECEIVERS
I
MANAGEMENT & CONTROL
SFP STEREO FM TO
FM RADIO PROCESSOR
Main features:
• RF input and output fully agile
87,5 to 108 MHz
• Double MPX output MPX input
(switchable) for local mpx
insertion in tunnel emergency
warning applications (see SFYRDS / SFP application note)
• Extensive measurement of
Deviation, RF, Pilot, BER and
RDS
• Supervising and alarm facilities
for RF level, Deviation, RDS,
Pilot etc.
• Alarm mode logging facilities
• Memory with 64 complete SFP
presets for easy installation
Remote controllable via IP over
SNMP and web browser
• Clock synchronised by RDS or
internal reference
I
CONTENT DISTRIBUTION
THE STANDARD FOR RE-BROADCASTING
AND CABLE HEAD-END
The IDC SFP, stereo FM to FM processor demodulates a FM signal to MPX and re-modulates
this to a new frequency. This enables the broadcaster or cable head-end operator to re-organize
the FM frequency spectrum without signal degradation or interfering RDS data. he SFP offers
in- and outputs for MPX, audio and external MPX control and advanced measurement of RF,
MPX deviation, pilot deviation, RDS deviation etc. For network management purposes the SFP
can be remote controlled via IP over SNMP and web browser.
Application: Tunnel Emergency Warning via FM Radio
TECHNICAL SPECIFICATIONS
Frequency input:
RF tuning stability:
RF input sensitivity:
RF inputs, main and spare:
Return loss:
87.5 – 108 MHz, 10 kHz steps
<500 Hz
5 to 110 dBuV
2 x BNC, 50.75 Ohm
>20 dB
SELECTIVITY
Narrow
Selectivity at + 90 kHz:
Selectivity at + 200 kHz:
Selectivity at + 300 kHz:
Selectivity at + 400 kHz:
Selectivity at + 300 kHz:
Wide
Selectivity at + 120 kHz:
Selectivity at + 200 kHz:
Selectivity at + 300 kHz:
Selectivity at + 400 kHz:
Selectivity at + 300 kHz:
Image rejection:
IF rejection:
AM rejection at 30% AM/75 kHz dev:
RF attenuation:
Adjacent channel suppression:
Muting threshold:
Stereo threshold:
Channel separation (wide):
Channel separation (narrow):
>-3 dB
>-54 dB
>95 dB
>110 dB
Iw/Iu = -23 dB (stereo)
>75 dB mono, >73 dB stereo
>70 dB mono, >64 dB stereo
S/N 1 KHZ (AT 75 KHZ DEVIATION)
RMS 20Hz – 20 kHz:
QP CCIR:
46 dBuV
65 dBuV
Phones:
MPX-output level:
MPX filter frequency
30 Hz – 65 kHz:
65 kHz – 76 kHz:
76 kHz – 100 kHz:
MPX output impedance:
Stereo jack 6.3 mm, 150 Ohm
from 0 dB to 11 dB (0,1 dB steps)
MPX connector:
>75 dB mono, >73 dB stereo
>70 dB mono, >54 dB stereo
S/N RELATATED TO RF INPUT LEVEL:
S/N 1 kHz (at 40 KHZ deviation)
RF level
S/N QP CCIR
(dBuV)
Mono (dB)
40
53
45
60
50
67
55
>68
60
>69
65
>70
70
>70
CORPORATE HEADQUARTERS:
50 Frank Nighbor Place, Kanata, ON, Canada K2V 1B9
Tel: 613-596-4120 Fax: 613-596-4863
Email: [email protected] www.datacast.com
All specifications subject to change. Printed in Canada. 03/08.
Stereo (dB)
33
41
46
>51
>55
>59
>60
+/- 0.3 dB
+/- 0.5 dB
- 6 dB down to 100 kHz
standard termination 600 Ohm
Minimum termination 75 Ohm
2 BNC connectors
RF MODULATOR
Frequency output:
>-3 dB
>-30 dB
>-65 dB
>- 100 dB
Iw/Iu = -23 dB (stereo)
>100 dB
>110 dB
>72 dB
automatic or manual
see selectivity specs
On/Off or adjustable
0 – 50 dBuV
Adjustable 20 – 50 dBuV
>48 dB 1kHz typical >50 dB
>45 dB 100 Hz – 500 Hz
>30 dB 10 kHz – 15 kHz
>30 dB 1kHz
MONITOR HEADPHONE
S/N 1kHz (at 75 kHz deviation)
RMS 20Hz – 20 kHz:
QP CCIR:
Saturation point mono:
Saturation point stereo:
RF carrier stability:
Spurious suppression:
RF connectors:
Return loss:
Maximum deviation:
Measurement Function
MPX deviation level:
RF level:
Pilot level 19 kHz:
RDS level 57 kHz:
RDS BER level:
RDS applications:
Alarm logging:
Adjustable 87.5 – 108 MHz
In 10 kHz steps
<1 KHz 0-50
>75 dB, 10 to 1000 MHz typical 80 dB
BNC, 75 Ohm
> 20 dB
depends on input signal
from 0 to 160 kHz (step 1 kHz)
from 0 to 120 dBuV
from 0 to 15 kHz (step 0.1 kHz)
from 0 to 6 kHz (step 0.1 kHz)
from 0 to 100% (step 1%)
MS, CT, RT, AF, PS, PI, DI, TA, TP,
PTY, Clock
64 levels of alarms, FIFO memory
DATA AND ALARM PORTS REAR PANEL
RCDS communication port:
MPX input:
MPX input pre-emphasis:
RDS/SCA input:
MPX output nr 3:
Alarm connection (3 contacts):
Alarm set up, menu-controlled:
MPX deviation level:
RF level:
Pilot level 19 kHz:
RDS level 57 kHz:
RDS BER level:
RS 485 / Sub D9 connector male
via SUB-D25 impedance 600 Ω
0 usec/stereo, 50 usec/mono
impedance 600 Ohm
600 Ohm for monitoring of receiver input
Sub D25 connector female
Alarm choice A/B/C delay 1-600 seconds
from 0 to 600 kHz (step 1kHz)
min/max RFfrom 1 to 119 dBuV
from 0 to 15 kHz (step 0.1 kHz)
from 0 to 6 kHz (step 0.1 kHz)
from 0 to 100% (step 1%)
IP PORT
Protocol:
Port type:
Communication type:
TCP/IP
Ethernet RJ45, 10/100 Mbps
SNMP
GENERAL
Main power:
Power consumption:
Power connection:
Headphones connection:
Safety and EMC:
Operation ambient temperature:
Housing dimensions:
Weight:
International Datacasting Corporation
EMEA Office:
Marga Klompélaan 18, 6836 BH Arnhem, The Netherlands
Tel: +31 (0) 26 323 69 69 Fax: +31 (0) 26 323 39 52
Email: [email protected] www.datacast.com
100 to 240 VAC, 50 to 60 Hz
maximum 45 Watt
IEC plug filter with fuse 2.5 AT
Stereo jack 6.3 mm
in accordance with CE regulations
4 to 45C (storage -5 to 65C)
19 inch x 1u x 300mm (depth)
4 kg