Operation Manual
VSI-Pro Version 12.00
Video Serial Interface
CAUTION!
RISK OF ELECTRICAL SHOCK!
DO NOT OPEN!
CAUTION! TO PREVENT ELECTRIC SHOCK, DO NOT
REMOVE COVER. NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL.
WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK, DO
NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE!
WARNING!
THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY AND IF
NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS MANUAL, MAY
CAUSE INTERFERENCE TO RADIO COMMUNICATIONS. IT HAS BEEN TESTED AND FOUND
TO COMPLY WITH THE LIMITS FOR A CLASS A COMPUTING DEVICE PURSUANT TO
SUBPART J OF PART 15 FCC RULES, WHICH ARE DESIGNED TO PROVIDE REASONABLE
PROTECTION AGAINST SUCH INTERFERENCE WHEN OPERATED IN A COMMERCIAL
ENVIRONMENT.
OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE
INTERFERENCE IN WHICH CASE THE USER AT HIS OWN EXPENSE WILL BE REQUIRED
TO TAKE WHATEVER MEASURES MAY BE REQUIRED TO CORRECT THE INTERFERENCE.
Copyright (c) 1993, 1994, 1995, 1996,
1997,1998,1999
TransAmerican International, Inc.
Index
M
P
R
S
T
U
83
82
Index
A
B
C
D
E
SET EXCEPTION
G
H
L
VSI-PRO IS YEAR 2000
COMPLIANCE
4
Contents
1. INTRODUCTION ....................................................... 5
2. FEATURES.................................................................. 6
3. CONNECTION ........................................................... 7
4. PROGRAMMING ..................................................... 10
4.1 FRONT CONTROL PANEL ............................................. 10
4.2 GETTING STARTED ........................................................ 12
4.3 MAIN PROGRAMMING MENU .................................... 12
4.3.1 REGISTER SELECT ..................................................... 13
4.3.2 SCREEN SETUP ............................................................ 15
4.3.3 TEXT DISPLAY ............................................................. 19
4.3.4 COMMUNICATION ...................................................... 23
4.3.5 EXCEPTION REPORTS ................................................ 26
4.3.6 ALARM OUTPUTS ....................................................... 37
4.3.7 TEST/DEMO MODE ..................................................... 42
4.3.8 DOWN/UP LOAD SETUP ............................................. 46
4.3.9 HELP .............................................................................. 50
APPENDIX A ............................................................... 51
APPENDIX B ................................................................ 55
APPENDIX C ................................................................ 69
APPENDIX D................................................................ 75
General Policies Effective 1998 .................................... 78
INDEX .......................................................................... 82
81
80
Use this page to make a written record of Exception Strings.
1. INTRODUCTION
The Video Serial Interface (VSI) allows characters to be inserted into any video source via an RS-232 link. This allows computers, cash registers, ATM's and any RS-232 communicating device to display alphanumerics in the video picture of a CCTV system. Simple front panel push-buttons allow the user to select position and gray scale of the inserted text as well as RS-232 commands.
Whether used with a cash register providing real time data on a RS-232 port or tapping off a serial printer, the VSI is a valuable tool in loss prevention. When used in conjunction with the American Video
Equipment Parallel to Serial converter (P2RS), the VSI can be connected to any computer printer port for a video display of what the printer is outputting. The VSI can be used to trigger switchers, Time
Lapse VCR's or other alarming devices.
5
6
2. FEATURES
• 45 Register Selection.
• Programmable Time-Stamp on Exception Output.
• Universal time/date format.
• 100 lines Exception History Buffer.
• 16 Triggered Text associated with 16 alarms.
• Larger data buffers for input/output to accommodate
newer, faster registers.
• 2 built-in Alarm Outputs.
• Powerful Data Filtering Algorithms.
• Easy On-screen Menu driven Setup and Programming.
• Auto Baud Rate Detection.
• 24 Field Programmable Exceptions with Numeric
Range.
• On-screen Flagging of Exceptions with Asterisk or
Reverse text.
• Programmable Alarm Outputs.
• Alarm Input for Drawer Open, Safe Open, etc.
• Serial Output of all data or Exceptions to Printers,
Computers, or Modems
• Programmable Delayed Screen Blanking.
• Choice of 1 to 9 lines displayed on-screen.
• On-screen Titler up to 20 Characters and up to 10
Character sizes.
• Gray Scale and Border Selection from front panel
• Built-in Test Mode
• Built-in Cash Register Demo
• Upload/Download Programming to a PC or another
VSI-Pro
• Data captured either to the memory or to the port
79
General Policies Effective 1998
Freight Policy
Products and Prices are shipped F.O.B. Houston, Texas.
Refused Shipments
All refused shipments will be subject to a 15% restocking fee and freight charges.
Shipping and Return Policy and Procedure
We are fully inspected our products to insure quality and carefully packed for delivery to you in good condition. In case that you are not satisfied with our products and must return them, please follow our Return Policy and Procedure.
•
No return is accepted after 30 days from the date of purchase.
•
Products returned for credit must be in unused condition and contained in its orignal package.
•
All return other than the products under the AVE manufacture warranty are subjected to 15% restocking and freight charges.
•
Call our customer service toll free number to obtain the RMA number (Return Material Authorization) prior to the shipment of the product to return.
•
The RMA number must be clearly displayed on all the shipping labels.
•
The RMA number is VALID ONLY FOR 15 DAYS from the issued date.
NOTE: The RMA number is required for all returned products, i.e. warranty and non-warranty products for services and repair.
78
3. CONNECTION
The VSI-Pro will overlay the characters on any input video source. The video input can be virtually any base band or composite video source. The VSI-Pro will accept NTSC, RS-170, RS-330,
CCIR, PAL or SECAM video formats.
The Video input to the VSI-Pro is a standard BNC connector, terminated at 75 ohms.
NOTE: The input video level must be 1V Peak to Peak. If this level is not maintained within +/- 20%, the VSI-Pro will have difficulty locking the character display over the input video source.
After completing the interface installation as described in the separate Installation Guide for your specific Cash Register, Computer, Radar Gun or other serial device. Connect the video input source to the video input BNC on the rear of the VSI-Pro. The BNC video output goes out to the video system (VCR, Quad, switcher,
Multiplexer, or monitor). This connection is shown in figure 1. The video output from the VSI-Pro is 1V Peak to Peak into a 75 ohm load. Most monitors or televisions with direct video inputs are terminated with a 75 ohm load. If the monitor is not terminated, the
VSI-Pro will output 2V Peak to Peak.
Note: The VSI-Pro will not enter the programming mode unless it is connected to a video source.
Included with the VSI-Pro is a 9 V @300 [mA] UL/CSA power supply which must be plugged into the POWER Input on the VSI-
Pro’s real panel.
7
CONNECTION
DB-9 (F)
VIDEO OUT
VIDEO IN
FIGURE 1: VSI-Pro Connections
Table 1 :Pin-out of the DB-9 connector on the VSI-Pro
7
8
9
5
6
3
4
P I N # F U N C T I O N
1
2
A l a
R e r m c i v e
O u t
D a
1 t a
T r
A a n
G l a s m
D r
D
R
C
T o u
S
T r m i t
T
R n d
R
S
S
D
O u t a t a
2
D I R E C T I O N
O p e n D r a i n
T o V S I P r o
F r o m V S I P r o
F r o m V S I P r o ( R e m a i n H i g h )
F o m V S I P r o ( S t a y H i g h )
T o V S I P r o
F r o m V S I P r o
O p e n D r a i n
8
HARD Alarm OUTPUT
P 1
19
6
18
5
9
21
8
20
7
11
23
10
22
13
25
12
24
15
2
14
1
17
4
16
3
0-12 V D C
0-12 V D C
A LM3
A LM2
A LM4
A LM6
A LM7
A LM5
A LM8
A LM11
A LM9
A LM10
G R O U N D
A LM16
A LM14
A LM13
A LM15
N C
A LM1 (TTL C O MP A TI A B L E )
A LM12 (TTL C O MP A TI A B LE )
N C
N C
N C
G R O U N D
G R O U N D
D B 2 5M
FIGURE 2B: VSI-PRO +16 DB 25 IN OUT
77
HARD ALARM OUTPUT
The VSI-Proprovides two open collector transistor alarm outputs to trigger alarming devices. Upon an Exception, a VSI-Pro can be programmed to trigger a VCR to go to its fastest record time, have a Quad go full screen, home a switcher, trigger a preprogrammed
PTZ, or provide visual or audible alarms. VSI-Pro provides two alaram output and VSI-Pro 16 provides 16 alarm outputs.
Following are some basic circuit designs to take advantage of
Alarm Output option of your VSI-PRo.
12 [ v ]
5 [ v ]
1k
R E S
10 k
R E S
LE D
A LA R A M O U P U T
LE D
A LA R M O U TP U T
INTERNAL
To
VSI-PRO
INTERNAL
To
VSI-PRO
TTL
5 [ v ]
INTERNAL
To
VSI-PRO
A LA R M O U TP U T
RELAY
CONNECTION
3.1 RS232 SERIAL INPUT
The VSI-Pro accept serial data via DB-9 female connector located on the rear of VSI-Pro. This Connector is similar to “AT” type computer RS232 serial ports and the pin out is identical. Table 1 shows the standard pin out for VSI-Pro RS-232 female connector.
On the other hand Table 2 compares the VSI-Pro RS-232 with standard “AT” computer’s RS-232 connector
Table 2: RS 232DB9 pin out vs VSI-Pro DB 9 Pin out
5
6
7
8
9
P I N #
1
2
3
4
S I G N
C
R
A
D x D
L
( C
N
( R
A M E a r r i e r e c i e v e
( R
D e t
D
S 2 e c t ) a t a )
3 2 )
T x D ( T r a n s m ti D a t a )
D T R ( D a t a T e r m i n a l R e a d y )
D
R
S
S
T
C
S
R
G
R
T
I
S
( S i g n a l
( D a t a S e t
( R e q u e s t
(
( C
R i l e a r n g I n
C d i o n t r o t o t o
R e c a
S e n d )
S e n d ) t o r )
)l a d y )
V S I P R O
A l a r m O u t 1
R x D
T x D
A l w a y s T r u e
G N D
A l w a y s T r u e
C T S ( O p it o n a )l
R T S ( O p it o n a )l
A l a r a m O u t 2
76
9
4. PROGRAMMING
The VSI-Pro is programmed by pressing and releasing specific combinations of the four front panel push-buttons. Via these four
Figure 2: Four Front Pannel Push Buttons of VSI-Pro simple buttons, all of the powerful programming features of the Text
Inserter are available. A video source and a monitor must be connected in order to see the programming menus.
4.1 FRONT CONTORL PANEL
The front panel controls are provided to allow simple changing of the display’s vertical and horizontal position and the gray scale or border. This eliminates the need of the user to enter the main menu and inadvertently change important programming setups.
10
APPENDIX D
Hard Alarm Output
75
PC Base Cash Register
There are myriad of PC based systems out there which do not appear on the AVE Cash Register Compatibility list. Most of
PC base cash registers that are not included in the AVE’s Cash
Registers compatibility list can interface to VSI-Pro. To find compatibility of cash register we need to determine following:
If the Cash Register using a stand alone receipt printer.
If “YES” then if it is a serial printer.
If “No” then if it is a Parallel printer.
If your printer is connected to a serial port then you can interface the VSI-Pro by using Com1 or com2 cable listed in the appendix B.
VSI-Pro can also interface with parallel printer ,if a high speed parallel to serial converter is connected either with cash register or with the printer. You can also use AVE’s high speed serial to parallel converter “P2RS” for interfacing VSI-Pro to the parallel port. Figure 1a shows AVE’s high speed P2RS converter.
Figure 1a. P2RS Parallel to Serise Converter
74
PROGRAMMING
Changing the Gray scale
Down
Up Set Reset
1) Press and hold the “Down” button
2) Press and release the “Reset” button
3) Release the “Down” button
4) Press “Down” or “Up” to select the Gray scale
5) When choice is made, press and release the “Reset” button
Changing the Horizontal Position
Down
Up Set
Reset
1) Press and hold the “Up” button
2) Press and release the “Reset” button
3) Release the “Up” button
4) Press “Down” or “Up” to move the text block
5) When choice is made, press and release the “Reset” button
Changing the Vertical Position
Down
Up Set
Reset
1) Press and hold the “Se”t button
2) Press and release the “Reset” button
3) Release the “Set” button
4) Press “Down” or “Up” to move the text block
5) When choice is made, press and release the “Reset” button
11
PROGRAMMING
4.2 GETTING STARTED
To access the main menu of the VSI-Pro, simultaneously hold down the “DOWN” & “UP” buttons and press & release the “RE-
SET” button and then release the “DOWN” & “UP” buttons. This will take you to the main programming menu as appeared in the figure 3. To navigate through this menu, simply use the “DOWN” &
“UP” buttons to position the arrow in front of the desired function, then press “SET” to access that section.
If you have difficulty entering the Main Menu, try the following procedure exactly: With your left thumb lightly press and hold in the 3 buttons to the left (Up, Down, & Set). While holding down these buttons, press and release the Reset button with your right thumb.
Then release the other buttons.
Note: If a sub menu has an "EXIT" selection, always go there and press
"SET". Pressing "RESET" at the main menu exits you from the program-
4.3 MAIN PROGRAMMING MENU
Following is a detailed description of the Menu selections and the programming capabilities of the VSI-Pro.
REGISTER SELECT
SCREEN SETUP
TEXT DISPLAY
COMMUNICATION
EXCEPTION REPORT
ALARAM OUTPUT
TEST/ DEMO MODE
DWN/ UP LOAD SETUP
HELP
Figure 3: VSI-Pro main menu
12
APPENDIX C
PC Base Cash Registers
73
72
PROGRAMMING
4.3.1 REGISTER SELECT
To select a specific register place the arrow cursor in front of
“REGISTER SELECT “ of the “MAIN MENU” and press and release “SET” button. The “REGISTER SELECT” will bring up a sub-menu consisting of registers shown in the Table 3. You can go to the next or previous page by placing the cursor in front of “NEXT” or “PREVIOUS “and then press and release “SET” button. To select desired register place the cursor in front of that register and then again press and release the “SET” button. After selecting the register, exit out of “ REGISTER SELECT” menu by placing cursor in front of exit and then press and release “SET’ button In the main menu press and release “RESET” button to activate the programing for that specific register. Register Select menu automatically formats the VSI-Pro to match your register’s communications settings
However, if you need to change these settings, you can do so through the “COMMUNICATIONS” menu described later in this manual.
NOTE: Whenever you select a register in this menu certain programming features are reset to the default settings. Always set the register selection first, get data on-screen, then proceed with additional programming.
TABLE 3: VSI-Pro register Menu
R E G I S T E R
G E N E R I C
A D D R E S S A B L E V S I
P C C O M 1 , 2 , 3 , 4
D E L T A S O N O 3 .
1
D R E S S E R W A Y N E
E D A C O M 9 0
E L C A
F U J I T S U 9 9 2 0
G A S B O Y
M O D E L
X
X
X
X
X
X
X
X
X
S P E C I A L M O D
X
P A S S I V E T A P
X
X
X
X
G 2 M O D
X
R S 4 8 5
13
PROGRAMMING
TABLE 3 : Continued
R E G
G I
G I
M
M I
M I
M
N
N
P A
I
I
I
O
I S
L B
L B
G I L B
M
I C
C R
C R
C
I X
T
A
A
R E
M
R
R A N
N A S O
R
C
C
S
O
O
A C O
B M
B M
E M 5
L E
P O S
A X
S
P O L E D I S P L A Y
S H A R P
S
N
I
S U N
C
D O
C
R
O
R
D
N
M
T R O N
S W E D A
I C
I C
S W I N T E C
U N I
T C I
T U C H
U N I W E L L
V E R F O N E
V S I D R S X
M O D E L
P C G S I T
T C R G / 2
T C R 1 5 ( O L D )
3 1 5 1 T E M I N A L
R D S
X
M A S T E R S E R I S E
9 5 0 0
X
X
L O C A L V S S
I D N N W O R K
I S N N W O R K
2 1 3 , 3 0 0 0
B E E L E
1 2 0 0
5 0 0 0
7 0 0 0
8 0 0 0
X
3 1 0 0 , 3 1 0
3 2 2 0 , 3 2 2 1 , 3 2 5 0
A 4 6 0 , A 4 7 0
A 5 5 0 , A 5 7 0
A 6 1 0 , A 6 5 0
A 7 5 0
X
8 9 0 , 8 9 1 , 9 6 0
2 0 0 0
5 4 X X
2 2 5 0
X
D S P 8 0 0
U N 4 0 2 5
X
X
S P E C I A L M O D
X
G 2 M O D
S P E C I A L M O D
X
X
X
X
X
X
X
M A X 2 3 2 O
4 8 5
R M O D
M I C R O S M O D
M I C R O S M O D
N C R 2 1 1 3 M O D
X
X
X
X
X
X
X
X
X
X
X
X
M O D 4 8 5
X
X
X
X
X
X
X
X
X
NOTE: As we continually add new registers, these menus are subject to change.
Note: See the Appendix B for the cable or triport pinout for all above registers.
14 71
70
PROGRAMMING
4.3.2 SCREEN SETUP
Place the arrow cursor in front of SCREEN SETUP and press and release “SET”. Screen set up menu will appears on the monitor as shown in figure 4.
. CHARACTER SIZE
. BORDER/ GRAY SCALE
. HORIZONTAL POS
. VERTICAL POS
. CLOCK
. ONSCREEN TITLER
. EXIT
FIGURE 4: VSI-Pro screen set up menu
Character Size
To change the size of the characters on the screen, position the arrow cursor in front of “ CHARACTER SIZE” and press and release “SET”. A grid of character blocks will appear on the screen.
Use “UP” or “DOWN" buttons to cycle through the selections. There are 10 character sizes to choose from. The character block is 9 lines by 20 characters for a total of 180 characters displayed on screen, however choosing a larger display size may not display all characters on screen. If the screen skews during this setup mode, this is normal.
Large characters off screen will effect most monitors this way.
Border Gray Scale
To change the display border and/or the gray scale of the text on screen, position the arrow cursor in front of “BORDER/GRAY
SCALE” and press and release “SET”. Cycle through the selections by pressing the “UP” or “DOWN” buttons. There are 10 settings to choose from. Make your selection and press and release “SET” to return to the main menu.
15
PROGRAMMING
Horizontal Position
To change the horizontal position of the inserted text on-screen, position the arrow in front of “HORIZONTAL POS” and press “SET”.
Press the “UP” or “DOWN” buttons to move the text to the desired horizontal position.
Vertical Position
To change the vertical position of the inserted text on-screen, position the arrow in front of “VERTICAL POS” and press “SET”.
Press the “UP” or “DOWN” buttons to move the text to the desired vertical position.
Clock
To program the clock's functions, set the SCREEN SETUP/
CLOCK entry, the menu shown in figure 5 appears on screen.
T/D DISPLAY ON
TIME FM 12 HOUR
DATE FMT MM/DD/YY
SET TIME/DATE
RESET TIME/DATE
T/D LOCKING ON/OFF
EXIT
FIGURE 5: Clock Display menu
T/D display is to turn the TIME/DATE display ON or OFF.
TIME FMT selects either 12 or 24 hour display with AM/PM.
DATE/FMT chooses one of the three available formats. mm/dd/yy or dd/mm/yy or yy/mm/dd
16
APPENDIX C
Pinout For Standard Connectors
69
68
PROGRAMMING
RESET TIME /DATE resets the clock to the default value.
T/D LOCKING turns the time/date locking on/off.
If the T/D Locking is turned on, make sure that the time format selected is the same as the register’s time/date format. If the T/D LOCKING is turned on, the VSI-Pro will monitor the incoming data string. If it finds a valid time and date in one or two consecutive lines, it will set the clock to whatever time/date it finds. A valid time has the following formats: hh:mm, hh:mm:ss hh:mm AM, hh:mm:ss AM hh:mm PM, hh:mm:ss PM where hh is a number between 0 and 12 (24 if either AM or PM not present).
A valid date has the same format as for date display and has either '/ ' ' or
'-" as separator.
On Screen Titler
Place the arrow in front of “ON SCREEN TITLER” and press and release “SET”. A sub-menu similar to figure 6 will be appears on monitor.
. TITLER OFF
.TITLE
. EXIT
FIGURE 6: ON SCREEN TITLER SUB MENU
17
PROGRAMMING
Titler
To change the status of the on-screen titler, position the arrow in front of “TITLER” and press “SET”. The arrow will start flashing.
Select either “ON” or “OFF” by pressing “UP” or “DOWN” button.
After making selection press and release “SET” button, this will return the arrow to the non-flashing mode. Now selct Exit to exit from titler sub-menu
Title
The VSI-Pro gives you the option of a 20 Character display for easy register identification in addition to the actual register transaction data.
To create a title, position the arrow in front of “TITLE” and press and release “SET”. You will see a row of 20 boxes and the first box will by flashing.
To change the character in the first position, press the “UP” or
“DOWN” buttons to cycle through the alphanumeric selections from the following list of available characters:
ABCDEFGHIJKLMNOPQRSTUVWXYZ
0123456789*-+.,:'=!?&][
The solid white box is used for a blank space. Make your selection and press and release “SET”. This will advance to the next block, repeat until you have entered the desired title. When finished, si-
multaneously press and release the “DOWN” & “UP” buttons to
enter your title into memory. The white boxes will disappear and
your title will be displayed as it will appear on screen. To return to the sub-menu and continue programming place the arrow in front of exit and press and release “SET”.
Note: Remember, enabling the TITLE will limit text insertions to 8 lines maximum.
18
TRIPORT AND ADAPTER CABLE
R J 4 5
1
2
5
6
3
4
7
8
VSI DRS
Cable: Contract factory
D B 9
2
3
4
5
8
7
4
6
67
TRIPORT AND ADAPTER CABLE
Unitouch
Cable : Consult Factory
Verifone
cable: Micromax,
D B 2 5 ( F )
3
7
D B 9 ( M )
2
5
D B 2 5 ( F )
3
7
D B 9 ( M )
2
5
66
PROGRAMMING
Exit
Place the arrow in front of the “EXIT” and press and release
“SET” button to return to the main menu.
4.3.3 TEXT DISPLAY
This menu will give you more control over the actual text block formatting and its appearance on the screen. To access the menu position the arrow in front of “TEXT DISPLAY” and press and release “SET”. Sub-menu similar to the Figure 7 will be appear on the screen.
. SCREEN BLANK 20
. DISPLAY LINES 9
. TRUNCATE OFF
. LINE COMPRESS OFF
. LEFT JUSTIFIED OFF
. SCROLL DELAY OFF
. DISPLAY ON
. EXIT
FIGURE 7: Text Display Sub-menu
Screen Blank
This is the amount of time that the VSI-Pro text display will remain on-screen after a transaction before blanking itself off (not the video picture, just the register transaction data) until the next transaction. The choices are (in seconds): NONE, 6, 12, 20, 30, 60, 120,
180, 300.
To change the “SCREEN BLANK” setting, place the arrow in front of SCREEN BLANK and press “SET”. The arrow will begin flashing. Now, by pressing the “UP” or “DOWN” buttons, you can cycle through the selections. Press and release “SET” when the desired time is displayed. The arrow stops flashing and you may continue programming.
19
PROGRAMMING
NOTE: Choosing “NONE” means No Blanking. The VSI-Pro will display the last transaction until a new transaction is performed.
Display Lines
You have the choice of how many lines of text to display onscreen for register transactions. The choices are upto 9 lines.
To change the “DISPLAY LINES” setting, place the arrow in front of DISPLAY LINES and press “SET”. The arrow will begin flashing. Now, by pressing the “UP” or “DOWN” buttons, you can cycle through the selections. Press “SET” when the desired number is displayed. The arrow stops flashing and you may continue programming.
NOTE: All register transaction data will scroll up regardless of the number of lines you choose to display on-screen and the more lines you display on-screen, the greater the amount of time that the transaction data will be recorded. However, some applications may limit the number of lines and the size of the on-screen display. Note: If you are using an on-screen title, it will occupy Line 1, leaving 8 lines for the text insertion.
Truncate
Truncate can be either “ON” or “OFF”. If “TRUNCATE” is
ON, then all text over 20 characters will be chopped off. If TRUN-
CATE is “OFF” then text will be wrapped to the next line. Position the arrow in front of TRUNCATE and press and release “SET”; the arrow will start flashing. Cycle between ON & OFF by pressing either the “UP” or “DOWN” buttons. After making your choice and it is displayed, press and release “SET”. The arrow will stop flashing and you can continue programming your VSI-Pro.
TRIPORT AND ADAPTER CABLE
D B 9 ( F )
2
3
5
7 , 6
1 , 4 , 8
D B 9 ( M )
3
2
5
S i C o m
Cable : cable Sicom
R J 4 5
7
3
Suntronic
Cable: Consult factory
S w e d a
Cable: Consult factory
SwinTec
Cable: Contract Factory
TCI
Cable: Micromax
D B 9 ( M )
2
3
20 65
TRIPORT AND ADAPTER CABLE
Sharp 3110, 3100
D B 9
5
2
D B 9 ( M )
5
2
Sharp 3220
D B 2 5
2
3
7
4 , 5
6 , 8 , 2 0
Sharp A-460, A-470, A550, A-570, A610, A650
D B 9
2
3
5
64
PROGRAMMING
Line Compress
NOTE: Set your Exceptions first, before enabling this feature.
The VSI-Pro automatically compresses the spaces in a line first as it reaches 20 characters. With LINE COMPRESS “ON” the VSI-
Pro will additionally remove multiple spaces and vowels from the text to further compress the display as necessary.
To make this selection, position the arrow in front of “LINE
COMPRESS” and press and release “SET”; the arrow will start flashing. Cycle through “ON” or “OFF” by pressing either the “UP” or
“DOWN” buttons, and press and release “SET” when your choice is displayed. The arrow will stop flashing, and you can continue programming.
Left Justification
When “LEFT JUSTIFIED” is on, the VSI-Pro will start each line of text with no leading spaces from the left margin of the text display block.
Scroll Delay
Scroll delay ensures that lines of text remain on screen a minimum of 0.5 seconds. This is specially useful with registers that run at a high Baud Rate or Time-lapse VCRs in extended record modes, switchers, or multiplexers. Sometimes, the register can produce characters so quickly that they can scroll up too fast on the screen to be recorded. When “SCROLL DELAY” is “ON”, the VSI-Pro slows down this data feed just enough to insure that each line of text is recorded.
21
PROGRAMMING
The choices for “SCROLL DELAY” are either “ON” or “OFF”.
To make this selection, position the arrow in front of “SCROLL DE-
LAY” and press and release “SET”. The arrow will start flashing.
Cycle through “ON” or “OFF” by pressing either the “UP” or
“DOWN” buttons, then press and release “SET” when your choice is displayed. The arrow will stop flashing, and you can continue programming.
NOTE: At high Baud Rates and Scroll Delay on the internal buffer of theVSI-Pro may overflow. This will cause lost text. The internal buffer can hold up to 20K characters before overflowing.
Display
You have the choice to globally turn on or off the complete VSI-
Pro text insertion function. This means no data will be visible on the monitor if you select “DISPLAY” off. However, if you select the
“DISPLAY” off, you can still command each exception independently to either display on-screen or not, through its program setup menu under “EXCEPTION REPORTS”. You may also choose to enable an alarm output to occur during an exception while not displaying the exception data through the program setup in the "ALARM OUT-
PUTS" menu. With the display “OFF” , the VSI-Pro will still perform all functions as programmed, for example; exception reporting will still function, but the information will not appear on screen unless programmed to do so in the "EXCEPTIONS REPORT" menu.
Exit
Place the arrow here and press and release “SET” to return to the VSI-Pro Main Menu.
TRIPORT AND ADAPTER CABLE
Panasonic
Cable: micromax cable
Pole Display
Cable: PC Com 2
D B 2 5 ( F )
3
7
D B 9 ( M )
2
5
D B 2 5 ( F )
2
7
D B 9 ( M )
2
5
22 63
TRIPORT AND ADAPTER CABLE
NCR 2113, 3000
cable: Consult factory
Nixdof Beetle
Cable: Consult factory
Norand
Cable: Cable Norand
Tap
Emulator
D B 2 5 ( F )
1
2
D B 9 ( M )
5
2
D B 2 5
1
2
3
D B 9 ( M )
5
3
3
62
PROGRAMMING
4.3.4 COMMUNICATION
This was discussed briefly in the section under “REGISTER
SELECT” and will be fully explained here. When you choose your register type under the “REGISTER SELECT” menu, this automatically formats the VSI-Pro to the appropriate settings needed to communicate with your register. There may be times when you will need to amend these settings for a specific register.
To access the “COMMUNICATIONS” menu, place the arrow in front of “COMMUNICATION” and press “SET”. This will bring up the sub-menu appears in Figure 8.:
RX BAUD RATE AUTO
TX BAUD RATE 2400
PARITY NONE
DATA BITS 8
HANDSHAKE OFF
AUTO LINE FEED ON
EXIT
Figure 8: Communication Main Menu
RX Baud Rate
Choices: AUTO, 150, 300, 600, 1200, 2400, 4800, 9600, 14.4K, 19.2K,
28.8K
To set the Baud Rate for your particular device, place the arrow in front of “RX Baud Rate” and press and release “SET”. The arrow will start flashing. You can now use the “UP” or “DOWN” buttons to make your selection. When your selection appears, press “SET again.
The arrow stops flashing and you can proceed to the next menu item for programming.
23
PROGRAMMING
TX Baud Rate
Choices: AUTO, 150, 300, 600, 1200, 2400, 4800, 9600, 14.4K, 19.2K,
28.8K
This is a new feature that allows you to set the transmit baud rate to a separate device if you are looping the data back out of the VSI-Pro.
To set the TX Baud Rate for your particular device, place the arrow in front of “TX BAUD RATE” and press and release “SET”.
The arrow will start flashing. You can now use the “UP” or “DOWN” buttons to make your selection. When your selection appears, press
“SET”; the arrow stops flashing and you can proceed to the next menu item for programming.
Parity
Choices: NONE, ODD, EVEN
Place the arrow in front of “PARITY” and press and release
“SET”. The arrow will start flashing. You can now use the “UP” and
“DOWN” arrows to make your selection. When your selection appears, press “SET”; the arrow stops flashing and you can proceed to the next menu item for programming.
Data Bits
Choices: 7 or 8
If you select 7 Data Bits, you must select “ODD” or “EVEN”
Parity in the Parity menu. Place the arrow in front of “DATA BITS” and press and release “SET”. The arrow will start flashing. You can now use the “UP” & “DOWN” arrows to make your selection. When your selection appears, press “SET”; the arrow stops flashing and you can proceed to the next menu item for programming.
TRIPORT AND ADAPTER CABLE
Micros, Local VSS
Cable: Consult factory
Micros IDN Network
Cable: Micro IDN cable
R J 1 1
4
3
2
1
Micros ISN Network
Cable: Micro ISN Cable
R J 1 1
2
4
D B 9 ( M )
7
8
3
2
D B 9 ( M )
3
2
24 61
TRIPORT AND ADAPTER CABLE
Micrelec
Note: consult Factory
MicroPos
Cable: Triport Micropos
(1) (2) (3)
1. RJ -45
2. Dual RJ-45 Jack
3. RJ-45 to DB-9 converter
R J 4 5
1
2
3
4
5
D B 9
4
3
8
2
7
MicroMax
Cable: Micromax Triport
D B 2 5 ( F )
3
7
D B 9 ( M )
2
5
60
PROGRAMMING
Hand Shake
Choices ON, OFF
Handshaking is an electrical signal that tells the Cash Register or Computer that the VSI-Pro is ready to receive data. It may not be necessary and/or may be connected to an outgoing signal from the
Cash Register or Computer since the VSI-Pro does not require Handshaking. In the VSI-Pro Handshaking signal is always present.
Handshaking guarantees that the internal buffer is not over run or text is not lost. Most AVE interfaces do not support this function.
Auto Linefeed
Choices: ON, OFF
Auto Linefeed makes the VSI-Pro send out CR/ LF after each line. The default of this function is “ON”, but if you would like to disable it then place the arrow in front of “AUTO LINEFEED” and press and release “SET”. The arrow will start flashing . You can now use the “UP” & “DOWN” arrows to make your selection. When your selection appears, press “SET”; the arrow stops flashing and you can proceed to the next menu item for programming.
Exit
Place the arrow in front of “EXIT” and press and release
“SET” to return to Main menu.
25
PROGRAMMING
4.3.5 EXCEPTION REPORTS
Exception Report Overview
The Exception Report gives you the option to assign an on-screen flag, trigger an alarming device, or send data to another serial device on any questionable transaction that you have preprogrammed into the VSI-Pro. The VSI-Pro will allow programming of up to 24 separate exceptions. These exceptions can be VOIDS, REFUNDS, COU-
PONS, PAID OUT, RETURNS, Individual Departments, Specific
Items, or any transaction that you determine (by programming -in) to be “exceptional” or questionable.
You may even set ranges for some exceptions; for example: All transaction over $100; between $8.00 to $25.00; or lower than .10
and greater than $25.00, all transactions by a specific cashier, or whatever transactions you need to watch “exceptionally” close.
On Screen Flags
You have several options for programming your Exception Report. The first option typically has all programmed exceptions display a flashing asterisk in the upper right corner of the on-screen display, or Reversing the entire Text Display. This ON-SCREEN
FLAG is controlled through the “ALARM OUTPUTS” menu. You assign a corresponding Alarm to an Exception and set the parameters for the FLAG in this menu. You do this by choosing “DISPLAY” for the corresponding Exception No. and selecting “ON”. With this option, all questionable transactions (exceptions) will be “flagged” with the flashing asterisk. You can then review these exceptions by putting your VCR in play and pressing the FF button. This will give you a fast scan of the tape and you can go into normal play when you see the flashing asterisk and view that transaction in real time or slow play or frame by frame, depending on the type of playback options
26
TRIPORT AND ADAPTER CABLE
Gilbarco TCR 15
Cable : Gilbarco Triport
IBM 3151 Terminal
Cable: Micromax triport
D B 2 5
2
7
D B 9 ( M )
2
5
MEM 5
Cable: Gilbarco Triport
D B 2 5
3
5
D B 9 ( M )
2
7
D B 2 5 ( F )
2
7
D B 9 ( M )
2
5
59
TRIPORT AND ADAPTER CABLE
D B 2 5 ( F )
2
7
Pc G- Site Customer Display Unit
Cable:
D B 9 ( M )
2
5
(1) (2) (3)
1. RJ -45
2. Dual RJ-45 Jack
3. RJ-45 to DB-9 converter
R J 4 5 D B 9 ( M )
2 2
4 5
Gilbarco TCR -G/ G2
Cable: G 2 cable
DB 37 (M)
D B 3 7 ( M )
4
6
DB 9(M)
D B 9 ( M )
3
4
58
PROGRAMMING
of your particular VCR.
Hard Alarm Output
The VSI-Pro allows you to program exceptions to trigger external alarming devices such as Time-Lapse VCR’s, Quads, Enunciators, LED’s etc. Using the Alarm Output you can have your timelapse VCR record only exceptions, or have an alarming Quad go to full screen on an exception, or even trigger a buzzer to alert you that an exception has occurred.
PRINTER OUTPUT
There may be situations where you do not want cashiers or other employees to know what triggers an exception. In this case, the VSI-
Pro provides a separate output that will send data to a remotely located serial printer. If you turn the on-screen display off and the output “ON” and you have a remote serial printer hooked up to the
VSI-Pro, then, whenever an exception is reported, it is sent out to the serial printer only. The printer will give you a hard copy printout of the questionable transaction with the time and date. With this hard copy printout of the exception report, you can then review the tape by going directly to that exception’s time.
The serial printer output of the VSI-Pro can be programmed to send out the entire transction. The output can be connected to the other equipment such as computers, phone line transmissions or digital storage devices for later retrieval
27
PROGRAMMING
Programming Your Exception Report
From the main programming menu, place the arrow in front of
“EXCEPTION REPORT” and press and release “SET”. This will take you to the Exception Reports' menu, which is shown in figure 9.
EXCEPTION HISTORY
SET EXCEPTION
OUTPUT ON
TIME STAMP OFF
EXIT
Figure 9: Exception Report Sub Menu
Exception History
Selecting this item displays the following submenu as appeared in figure 10.
TOTAL EXCEPTION 000
VIEW EXCEPTION
OUTPUT EXCEPTIONS
CLEAR HISTORY
EXIT
Figure 10: Exception History Submenu
Total Exception will tell you that how many exception stored in the buffer. Total Exception would be between 000 to999.
Select 'VIEW EXCEPTIONS' to display buffered exceptions
28
TRIPORT AND ADAPTER CABLE
Edacom 90
Note: Consult Factory
Ecla
Note: Consult Factory
Fujitsu 9920
Note : Consult Factory
G a s b o y
Cable : Cable Gas boy
DB 9 (MALE) RJ 45 (FEMALE)
RJ 45 (MALE)
D B 9 ( M ) R J 1 1
4
6
3
4
Gilbarco PC G-site
Cable: Gilbarco Triport
DB 25 DB 9 (m)
57
TRIPORT AND ADAPTER CABLE
Generic
Cable: Consult Factory
Addressable VSI
Note: Consult Factory
PC COM 1,2,3,4
Note: Consult Factory
Delta Sono
Note: Consult Factory
Dresser Wayne
Cable: Dresser Wayne
DB-9M
56
DB-9F
D B 9
3
5
D B 9 ( M )
2
5
DB-9M
PROGRAMMING
on the screen, starting with the oldest exception in the buffer. Once in the exception displaying screen, pressing DOWN or UP keys scrolls to next screen. Press the SET button to return to main menu.
Select OUTPUT EXCEPTIONS to have the buffered exceptions sent out for printing.
Select CLEAR HISTORY to clear all the buffered exceptions and reset the TOTAL EXCEPTIONS Counter.
Selecting ''EXIT' brings you back to the Exception Report main menu.
Set Exception
On this main menu: Select 'SET EXCEPTIONS' to bring you to the SET EXCEPTION setup menu appeared in Figure 11.
EXCEPTION NO. 1
DISPLAY
OUTPUT
ON
ON
EXCEPTION STRING
NO SALE
RANGE
0000.00 <-> 0000.00
OPERATOR NONE
EXIT
Figure 11: Set Exception Sub menu
Exception No.
Choices: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20,
21, 22, 23, and 24.
To select the Exception No. that you wish to program, place the arrow in front of “EXCEPTION NO.” and press and release “SET”.
The arrow will start flashing . Use the “UP” & “DOWN” buttons to
29
30
PROGRAMMING
sequence through the choices. Make your selection and press and release “SET”. The arrow will stop flashing and you may continue to the next menu item.
Display
Choices: ON or OFF
The “DISPLAY” item lets you control whether or not this particular exception is displayed on the video monitor. Please understand that you are not using a remote serial printer and if you do not turn on the Exceptions display here, you will not have the onscreen flag and consequently no record of the exception when it occurs.
To make your selection, place the arrow in front of “DISPLAY” and press and release “SET”. The arrow will start flashing. Use the
“UP” or “DOWN” buttons to toggle between “ON” or “OFF”. Make your selection and press and release “SET”; the arrow will stop flashing and you may continue to the next menu item.
Application Note: If the display of the Exception is turned off here, the exception data will actually be erased from the screen. This feature can be used to generate what we refer to as “negative exceptions,” allowing the removal of unwanted text from the screen. See “Negative Exceptions” on Pg. 32 of this manual.
APPENDIX B
Triports and Adaptors cable
55
PROBLEM SOLVING GUIDE
My customer is changing registers; will the VSI they have work on the new register?
This is a tricky one. We interface to over 400 different registers and as a result, there are several versions of software needed to work with all these different systems. The probability the VSI will work with a new system is relatively high, specially if it’s Version 11 based. The chances any additional boards or boxes will work is lower, unless your customer is staying with the same manufacturer and within the same register series.
Call AVE’s Product Support Specialists for additional help along these lines.
If I install your interface board into a new register, will it void my customer’s warranty?
If you are connecting to an external RS 232 port of the Register, generally it does not void the warranty. But if you want to add the interface board in your new cash registrer, we will highly recommend you to see call the
Manufacture of you cash register.
I installed a VSI-Pro and the On-screen Text jumps or jitters.
Our VSI-Pro text inserter requires the input video signal to be 1V P-P +/-
20%, terminated @ 75ohms. If this voltage varies either too high or too low, then the VSI has trouble syncing the text to the video.
There are a couple of things you can try to help settle the text down. Change the gray scale level of the text block from the whitest level to one of the slightly lower gray levels. Changing the size of the text block may help.
Sometimes moving the text block away from the edge of the screen may help settle the text down too.
If these don’t seem to have an effect then try using a distribution amp like
AVE’s VDA-601 to properly adjust the video level.
If the camera you’re using has an auto iris lens, try adjusting the iris to average and then reduce or increase the level.
54
PROGRAMMING
Output
The “OUTPUT” controls the RS-232 data from the VSI-Pro.
Typically this is sent to a remote Serial Printer to provide a hard copy of Exceptions with time and date on it. This data can also be sent out to a computer with appropriate software and give you the ability to analyze data. You could also use an auto answer modem and have the data to sent to a central office or even to your home. The serial devices must have the same Baud Rate, Parity, and Data Bits as the
VSI-Pro for optimum performance of data transfer.
To make your selection, place the arrow in front of “OUTPUT” and press and release “SET”. Use the “UP” and “DOWN” buttons to toggle between “ON” or “OFF”. Display your selection and press and release “SET”. The arrow will stop flashing and you may continue to the next menu item.
PROGRAMMING NOTE: The following sections defines the Exceptions Strings, the operator and the Range. The Exception Strings is programmed first, then Range is defined and finally the Operator is selected. The VSI-Pro looks at the Exceptions
Strings first, and if there is data that matches, it then check to see if a range has been defined.
Exception String
The VSI-Pro compares the data that is printed to video to the data entered in the Exception String. The Exception String can also be used without a define range. Example of this would be to assign a word “ VOID” as an exception. VSI-Pro will look for that string so range definition is not necessary. However, exception string “ Void” could be further defined by assigning a Range, i.e., all “VOID” over
$20.
You can also define a “Global” exception to flag all negative transactions. An example of this using the Samsung ER-4715 would be the following exception to flag any transaction that contains a “-”
31
PROGRAMMING
or negative sign. For example in Samaung ER-4715 register an assign Exception string “..-” will flag all Void, Refund, Merchandise
Return and Paid out to the monitor.
You can also use wild card symbol “.” a centered dot on any data location. Example of this would be instead of assigning eight different exception string for dept 00 to dept07 you can assign only one exception string e.g. “dept . .”. That wild card exception string will handle exception for all eight departments.
To program the “EXCEPTION STRING” place the arrow in front of it and press and release “SET”. The first 20 character exception will become active after flashing. Program in your exception string
Note: Remember to enter your Exception String based on the way that data prints to video, including spaces. Also remember “SET” advance to the next position.
Pressing “DOWN” and “UP” at the same time enters the string into memory and returns to the sub menu for further programing.
TIP: If you make a mistake and need to erase a character, pressing the “UP” and
“SET” same time will change the character back to black.
Negative Exception
You can remove unwanted text from the screen using VSI-Pro.
The VSI-Pro displays data in the text block 9 lines by 20 characters wide for total of 180 characters. To remove unwanted messages from the register data you first determine how the unwanted messages prints to the video. For example, a typical message which scrolls on the customer display or appears on the video monitor:
WELCOME TO XYZ SUPERS STORE
The removing of above string is referred as the Negative Exception. Follow the steps to program Negative Exceptions. Turns
32
PROBLEM SOLVING GUIDE
Characters Jitter, Jump or Skew
Note: The VSI requires 1V p-p +/- 20 percent, terminated @ 75 ohms.
1. Darken the gray scale of the characters.
2. Video Input level less than 1VP-P - use an amplifier to get the proper level.
3. Poor input sync signals - too many AC coupled amplifiers in the
video input signal.
4. Noisy or poor quality video source- Replace with better source.
5. Check for double termination.
6. Video level too high; VSI-Pro will clip video.
7. Text is too close to the edge of the screen. Try repositioning the text.
8. Too much light in the video picture may cause character distortion.
Reposition the camera or reduce the amount of light to which the
camera view is exposed.
Funny characters or garbage on screen.
1. Power disconnected for too long and memory is lost.
2. Lightning strike , power line noise or power surge.
3. CR boards- make sure data cable is plugged in correctly.
4. Ground and Data wires are reversed. Verify correct DB-9 cable
wiring.
How to do a Master Reset on VSI-Pro.
1. Press and hold in simultaneously the DOWN, UP and SET buttons.
2. While holding those three buttons in, press and release the RESET button
and then release the other three.
3. This will display copyright notice.
4. VSI-Pro restore all the factory default settings.
53
PROBLEM SOLVING GUIDE
No data on screen.
1. Press the reset button on the VSI-Pro front panel.
2. Incorrect register selected in the Register Select Menu.
3. Data cable is miswired.
4. Data cable is too long or did not use shielded cable.
5. May be connected to the wrong port.
Problems With CR boards
1. Check that the board is seated properly in the register.
2. Check jumper settings on the CR board if applicable.
3. On CR-700, 800 and 900 series boards, make sure the 2 pin data cable
is plugged in correctly.
4. On CR-220 series board, make sure the 2 pin data cable is plugged in
correctly.
Problems With N2RS, NCR2RS, DTS2RS,B2RS ETC..
1. Check the cable to the register.
2. If VSI was working and stopped, power cycle thesystem. Turn off the
register, unplug the power to the N2RS, unplug the power to the VSI.
Now power up the system, plug in the VSI & the N2RS Turn on the
register and do a transaction. The data should reappear.
3. Check the cable between the VSI and the N2RS.
No video on monitor.
1. VSI transformer not plugged in, or is malfunctioning.
2. Video In/Out connectors reversed, or BNC connector is not correctly
wired.
3. No video input signal.
4. Bad video cable or connector.
5. Camera Iris is closed.
6. Other video device in system is off or malfunctioning.
52
PROGRAMMING
the display off for that exception. In the Exception Strings enter the words “ WELCOME TO XYZ SUPER ”. Exactly as they appears on the screen, including spaces. ( Note: Only 20 characters are al-
lowed in each exception string, including blank spaces ).
OPERATOR
The “OPERATOR” determines the behavior of the “RANGE”.
Think of the OPERATOR in mathematical terms. Setting the correct range and specifying IN or OUT will make the OPERATOR perform
Greater Than, Less Than, Equal To, IN the Range, or OUT of the
RANGE calculations.
With this version of the VSI-Pro, you can define ranges for your
Exceptions and have the VSI-Pro alarm when an Exception falls within the range’s parameters or outside the range of the two numbers. The choices are: IN, OUT, and NONE.
To Program the operator , place the arrow in front of “OPERA-
TOR” and press and release “SET” button. The arrow will start flashing. Use the “UP” and “DOWN” buttons to make your selection.
When your selection is displayed, press and release the “SET” button. The arrow will stop flashing and you may continue to the next menu item.
RANGE
The range defines the limits of the operator. These are numeric only. As you can see from the previous examples, the range has two separate fields that are separated by a double-sided arrow. This format must be followed.
To program Range place the arrow in front of “RANGE” and press and release the “SET” button, the first “0” in the“ Range” starts to flash. This means it is active and ready for programming. To
33
PROGRAMMING
change the value of this character, use the “UP” or “DOWN” buttons to move between 0-9. To move to the next block, press and release the “SET” button. This will advance the active block to the next block immediately to the left . This is how you move through the
“RANGE” field.
While you are on an active block, pressing the “UP” and “SET” buttons simultaneously will return that block back to a blank, which is designated by a solid white box. You can follow this format to program your “RANGE”. When you have finished and wish to set this range into the VSI-Pro memory, simultaneously press and release the “UP” and “DOWN” buttons.
When you are ready to exit and continue on, simultaneously press and release the “UP” and “DOWN” buttons; this will set the range in the VSI-Pro memory and exit you back to the Exception
Report Sub-Menu.
OUTPUT
This is global output to send data to the serial printer. When
“ON” is selected all the data will be send to the serial printer regardless of what setting of out put has selected in the individual output in set exception menu. When “ OFF” is selected only those exception will send to the serial printer whose out put is “ON” under set exceptions menu for individual exceptions.
To turn output “ON” or “OFF” place the arrow cursor in front of out put and press and release “SET” button. After selecting a choice again press and release “SET” button , arrow will stop blinking and ready for your next command.
Time Stamp
If Time Stamp is selected “ON” then printer will print the ex-
34
APPENDIX A
Problem Solving Guide
51
PROGRAMMING
The data transfer will start and you will have a screen count down of the status that reads:
Programmed VSI
UPLOADING ...1
Unprogrammed VSI
DOWNLOADING ...1
The count will end at 99. When this prompt clears the screen, the data transfer is complete. Press Reset to exit this menu on both
VSI-Pro’s.
Now go to the main programming menu of the previously unprogrammed VSI-Pro on the right side of the screen. Enter the EX-
CEPTIONS menu. You should see your exceptions and other programmed data just as they were on the original programmed VSI-
Pro.
NOTE: For locations or companies with a large number of interfaces, we strongly advise that you keep one programmed VSI-Pro as a master and a backup to insure your system integrity. This will also aid in reprogramming any changes and protect against any catastrophic events.
UPLOADING/DOWNLOADING VIA A PC
You can use a Laptop PC and AVE’s IC or equivalent communications program to store data from a VSI-Pro to a file. This file can then be uploaded to other VSI-Pro units with the same software revision level. Use 4800 baud for the PC’s baudrate.
4.3.9 HELP
HELP in the Main Menu provides a quick reference guide of the function of the UP and DOWN and SET button.
50
PROGRAMMING
ception with time stamp flag, otherwise just print the Exception.
To turn Time Stamp “ON” or “OFF” place the arrow cursor in front of Time Stamp and press and release “SET” button. After selecting a choice again press and release “SET” button , arrow will stop blinking and ready for your next command.
Exit
Place the cursor in front of Exit and press and release set button to exit out of Exceptions Report sub menu.
Examples for Setting Exception
EQUAL
Suppose Exception #2 would be flag all $10 sales on Register Department
1. This would be the settings for this Exception:
(For these examples, we are using the Samsung ER-4715 Electronic Cash
Register):
Exception No. 2
Display ON
Output ON or OFF (depending on presence of serial printer)
Exception String 1 . . .
Range 0010.00<->0010.00
Operator IN
Out Range
Suppose Exception #3 would “FLAG” every transaction on Department 2 that is under 10 cents and over $100 dollars. This would be the settings for this Exception:
Exception No. 3
Display
Output
ON
ON or OFF (Depending on presence of serial printer).
Exception String 2 . . .
Range 0000.10 <-> 0099.99
Operator OUT
35
PROGRAMMING
In Range
Suppose Exception #5 would flag all transactions between $50.00 &
$100.00 on Department 3:
Exception No. 3
Display ON
Output
Exception String
ON or OFF (Depending on presence of serial printer).
3 ...
Range 0049.99<->0099.99
Operator IN
With this exception all sales between $50 and $100 dollars will be flagged.
GREATER THAN
This example will show you how to program an exception to flag all sales in department 5 greater than $100 dollars
Exception No. 2
Display ON
Output
Exception String
ON or OFF
5...
Range
Operator
0000.01<-> 0099.99
OUT
Now whenever anyone rings a sale of $100 or more on Department 5, the transaction will be flagged.
Less Than
This example will show you how to program an exception to flag all sales in Department 6 of less than $100. 00:
Exception No. 4
Display ON
Output ON or OFF
Exception String
Range
Operator
6
0000.01<->0099.00
IN
36
PROGRAMMING
:
Lets bring up the PROGRAMMED VSI-Pro first. To do this, simultaneously press and hold “UP” and “DOWN” and press and release “RESET” , then release “UP” and “DOWN”. This will bring up the main menu and it should be on the left half of the screen. Now go to the other VSI-Pro and do the same thing. You should now have both programming menus side by side.
NOTE: Depending on the size of the monitor you are using, these two menus may overlap, but should not be a problem.
To proceed with the DOWNLOAD/UPLOAD, we will configure the UNPROGRAMMED VSI-Pro first. To do this, place the arrow in front of “DWN/UP LOAD SETUP” on the main menu on the right side of the screen. Press and release “SET”. This will take you to the sub-menu appeared in figure 17.
DOWNLOAD SETUP
UPLOAD SETUP
EXIT
BNC to BNC Cable
Figure 17: Down/Up Load Sub Menu
The arrow should be pointing to “DOWNLOAD SETUP”. Press and release “SET”. You will see the prompt “DOWNLOADING ...”.
This VSI-Pro is now waiting to receive data from the PRO-
GRAMMED VSI-Pro. Now go to the menu of the PROGRAMMED
VSI-Pro and follow the instructions above to get to the “DOWN/UP
LOAD SETUP”. Press and release the “SET” button to go to the sub-menu. Now place the arrow in front of “UPLOAD SETUP”. We are now ready to perform the data transfer. Press and release “SET”.
49
PROGRAMMING
CAMERA IN
VIDEO OUT TO MONITOR
Figure 16: Down Load Set Up Between VSI-Pro and VSI-Pro and “DOWN” buttons, you can move the display side to side on the screen. Move the text block as far to the left as you can and press
“RESET” to exit.
Now let’s move the display to the top of the screen. Hold down the “SET” button and press and release “RESET”, then release “SET”.
Now the “UP” and “DOWN” buttons will move the display up and down on the screen. Move the display to the top of the screen. When you have it in the correct position, press “RESET” to exit.
Go to the other VSI-Pro and this time follow the same instructions except we want this display on the right side of the screen.
After you have both displays positioned properly, we need to bring up both programming menus.
48
PROGRAMMING
4.3.6 ALARM OUTPUTS
To access alarm output, place the arrow in front of “ALARM
OUTPUTS” and press and release “SET”. You will be presented with the following sub-menu shown in figure 12.
ALARM NO.
ALARM TRIG
NORMAL STATE
ALM DURATION
FLAG TYPE
FLAG DURATION
RTS TRIGGERED TEXT
EXIT
Figure 12: Sub menu for Alarm Output
The ALARM OUTPUTS menu controls not only the formatting of the external alarms, but also the formatting of the on-screen flags assigned to individual exceptions.
ALARM NO
The VSI-Pro allows you 2 and VSI-Pro 16aloows you up to 16 alarm outputs that may be used with any of the user programmed exceptions. To select the Alarm Number that you want to program, place the arrow in front of “ALARM NO.” and press and release
“SET”. The arrow will start flashing . By using the “UP” & “DOWN” buttons, toggle through and make your selection. When you have made your selection, press and release “SET”; the arrow will become solid and you may continue programming your VSI-Pro.
37
PROGRAMMING
ALARM TRIG
An ALARM TRIGGER is the source of activity programmed to activate a certain alarm. The Alarm Trigger tells the VSI-Pro what exception to use to trigger the alarming device or the on-screen flag.
The choices are: Exceptions 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15,
16, 17, 18, 19, 20, 21, 22, 23, & 24: (alarms when data is received that matches what you have set in these exception strings).
Exceptions 1-12: alarms when data is received that matches any data set in Exception 1-12.
Exceptions 13-24: alarms when data is received that matches any data set in Exception 13-24.
Exceptions 1-24: alarms when data is received that matches any data set in Exception.
RTS: External alarm input. The VSI-Pro has 1 alarm input, if you are not using the handshaking function. A contact closure to ground on pin 7 (pin
5 is ground) will trigger this alarm. Coupled with the RTS Triggered text, you can now display a 20 character message from an external alarm input.
RTS Application Note: The RTS alarm input can be connected to a timer on the
drawer of a cash register to alarm and send the message "DRAWER OPEN" to the screen if the drawer is open too long.
To select the Alarm Trigger that you want to program, place the arrow in front of “ALM TRG” and press and release “SET”. The arrow will start flashing . By using the “UP” & “DOWN” buttons, toggle through and make your selection. When you have made your selection, press and release “SET”. The arrow will become solid and you may continue programming your VSI-Pro.
38
PROGRAMMING
3 --------------2
2 --------------3
5--------------5
Figure 15: download data cable
UP LOADS would be to have a system set up with two separate cameras and monitors and the programmed VSI-Pro with the down load data cable attached. The VSI-Pro programming data is stored internally on an EEPROM. This would allow you to program one VSI-
Pro on site and bring the programmed VSI-Pro back to the shop or office and program additional VSI-Pros quickly. We realize this may not always be possible to do, and that there may be a need for field programming. The only problem with field Down/Up loading is the need to access the programming menu of each VSI-Pro. The use of a portable monitor and diagram in figure 16 will let you perform the
Down/Upload in the field. For this, you will need a short BNC to
BNC cable approximately a foot long, the data cable and a monitor that can be used next to the VSI-Pro.
The programmed VSI-Pro will UPLOAD data to the unprogrammed VSI-Pro. In the configuration on the figure 16, you can get the programming menus from both VSI-Pros on the screen at the same time. Let’s use the front panel shortcut to position the text block from the PROGRAMMED VSI-Pro on the left side of the screen. To do this, press and hold down the “UP” button, then press and release “RESET” and release “UP”. Now, by using the “UP”
47
PROGRAMMING
from a real register. You can use this demo data to configure exceptions and alarms to be fully functional for a complete customer demonstration.
To access this demonstration, place the arrow in front of REG-
ISTER DEMO and press and release “SET”. The demo will start after a few seconds. To exit this demo, press and release “RESET”.
Version ID
When selected display the version of software in use by the VSI-Pro.
LOGO
This demo displays the AVE logo cycling through several sizes.
To access this demonstration, place the arrow in front of LOGO and press and release “SET”. The demo will start after a few seconds.
EXIT
Selecting EXIT returns you to the main menu for further programming.
4.3.8 DOWN/UP LOAD SETUP
This feature lets you UPLOAD or DOWNLOAD data between
VSI-Pro’s or VSI-Pro and a PC. This is especially helpful on multiinterface installations. You can program one VSI-Pro, then download the data to another VSI-Pro with the DOWN/UPLOAD feature, using a download data cable shown in Figure 15.
VSI-Pro To VSI-Pro Data Transfer
To insure that the data upload or download is accomplished, you need to access the programming menu, so each VSI-Pro needs a video input and a monitor. The optimum way to perform DOWN/
46
PROGRAMMING
NORMAL STATE
There are two choices: NO (normally open) or NC (normal closed). These selections determine whether the alarm outputs will act as a normally open switch or a normally closed switch.
To select the Normal State that you want to program, place the arrow in front of “NORMAL STATE” and press and release “SET”.
The arrow will start flashing . By using the “DOWN” & “UP” buttons, toggle through and make your selection. When you have made your selection, press and release “SET”; the arrow will become solid and you may continue programming your VSI-Pro.
ALARM DURATION
This is the amount of time in seconds that the alarm will remain activated once it is triggered. The selections for alarm duration are:
PULSE, 6, 12, 20, 30, 60, 120, 180, and 300 seconds. (PULSE sends a 200mS alarm pulse to the alarm device.)
To select the amount of time in seconds that you want to program the alarm duration, place the arrow in front of “ALM DURA-
TION” and press and release “SET”. The arrow will start flashing .
By using the “DOWN” & “UP” buttons, toggle through and make your selection. When you have made your selection, press and release “SET”; the arrow will become solid and you may continue programming your VSI-Pro.
FLAG TYPE
This feature allows you to insert a visual alarm flag on each exception that you program to aid in the review of the video tape.
This flag can appear as an asterisk “*” , a flashing asterisk, reverse text, or flashing reverse text.
39
PROGRAMMING
To make your selection place the arrow in front of “ FLAG
TYPE” and press and release “SET”. The arrow will start flashing .
By using the “DOWN” or “UP” buttons, toggle between the choices and make your selection. When you have made your selection, press and release “SET”; the arrow will become solid and you may continue programming your VSI-Pro
FLAG DURATION
This is the amount of time in seconds that the on-screen FLAG, either the Asterisk or the Reverse mode, will remain activated once it is triggered.
NOTE: Flag duration is independent of the Alarm Duration. Flag Duration is the amount of time the On-Screen flag will remain on after activation, while,
ALARM DURATION is the amount of time that the HARD WIRE Alarm ourputs remain activated after it is triggered.
The selections for “FLAG DURATION” are:
6, 12, 30, 60, 120, 180, and 300 seconds.
To select the amount of time in seconds that you want to program for the flag duration, place the arrow in front of “FLAG DU-
RATION” and press and release “SET”. The arrow will start flashing. By using the “DOWN” & “UP” buttons, toggle through and make your selection. After you have made your selection, press and release “SET”; the arrow will become solid and you may continue programming your VSI-Pro.
TRIGGERED TEXT
A Triggered Text is a data string that associates with one of the 16 alarms or with external RTS alarm. When the alarm is triggered by a source, the associated string is sent out and/or displayed,
40
PROGRAMMING
non RS 232 format data.
Capture to memory
This feature allow you to store the data in the internal memory of VSI-Pro. You can store up to 28 kilobytes of data in the internal memory of VSI-Pro. Power up the VSI-Pro 24 hour prior to down load data. That will keep data in VSI-Pro’s internal memory for an extended period of time . To start downloading place the arrow infront of Capture to the memory and than press and release the “SET” button.
Note 1: VSI-Pro can only hold up to 28 kilo bytes of data to make sure that you only transfer the data which is in correct format.
Note 2: Any Programming or data transfer of any kind can over write the stored data in memory.
Dump mem
You can upload any saved information from the VSI-Pro memory to any PC or some specific communication devices using appropriate up load cable. To upload the information in PC you must have any communication software which can transfer the binary data. To up load the memory place the arrow in front of “Dump mem” and press and release the “SET” button. VSI-Pro will start uploading the data.
Register Demo
This demonstration simulates transaction data from a register.
This is used to demonstrate the VSI-Pro’s capabilities with just a monitor and camera without having a register hooked up. When the demo mode is active the VSI-Pro thinks the data is actually coming
45
PROGRAMMING
RX/ TX TEST
In the RX/ TX test VSI-Pro echo whatever it receives. To proceed with test, place the arrow in front of “RX/TX TEST” and press and release SET.
Baud Rate Scan
Baud Rate scan test can scan the baud rate of your register. To proceed with the test, place the arrow in front of baud rate scan and press and release “SET” button. Enter a transaction from the register, VSI-Pro will detect the baud rate and display it in front of RX
Baud rate.
EXIT
Place arrow in front of EXIT to return to Test / Demo mode sub menu.
Data Capture
This feature allow user to store the data to either internal memory of VSI-Pro or some external data storing device. To access DATA
CAPTURE sub menu place the arrow in-front of “ Data Capture” and press and release the “SET” button. Figure 15 showing the Data capture sub menu.
CAPTURE TO PORT 1
CAPTURE TO MEM
DUMP MEM
EXIT
Figure 15: Sub menu of Data Capture
Capture to Port 1
This feature redirect the incoming data to VSI-Pro to its output
(pin 3 of AT type RS 232 female connector ) where that data can be stored to data storing devices (e.g. PC). This feature is useful to store
44
PROGRAMMING
if enabled respectively. Each Triggered Text can contain up to 40 printable ASCII data. If non-printable data (control code) is included, each control code occupies 3 printable spaces. Therefore, only 13 control codes maximum can be programmed in one Triggered Text.
To program the TRIGGERED TEXT, go to the ALARM OUT-
PUTS sub-menu. Select desired ALARM NO or RTS for external alarm. Then go to the TRIGGERED TEXT sub-menu this is same as what appeared in figure 13.
DISPLAY TEXT
OUTPUT TEXT
OFF
OFF
SET TRIGGERED TEXT
EXIT
Figure 13: Triggered text sub menu
Display Text
Place the arrow in front of “Display Text” and press and release the “SET” button. Arrow cursor will start blinking. Now select either “ON” or “OFF” by pressing “UP” or “DOWN” button. Selecting “OFF” will not display any exception text on the video out put.
Out Put Text
Place the arrow in front of “Out Put Text” and press and release the “SET” button. Arrow cursor will start blinking. Now select either “ON” or “OFF” by pressing “UP” or “DOWN” button. Selecting “OFF” will not send any exception text to the serial printer.
41
PROGRAMMING
Set Triggered Text
Place the arrow in front of Set Triggered Text and press and release “SET” button. You can enter 2 lines with 20 alpha numeric text on each line. Press “UP” and “DOWN” at the same time to exit out of Set triggered text .
You can also enter non-printable data (control code) instead of triggered text. Each control code occupies 3 characters, therefore you can enter 13 control code ina line. To enter control code first print uparrow ^ followed by 2 hex digit. For example hex code 01 has to be entered like ^ 01.
Exit
Selecting “Exit” will return to VSI-Pro main menu.
4.3.7 TEST/DEMO MODE
The TEST /DEMO MODE provides you with several ways to test the VSI-Pro and demonstrate its capabilities as a cash register interface. To access this section, place the arrow in front of TEST
DEMO MODE and press and release the SET button . You will be presented with the sub-menu appeared in Figure 13:
PORT 1 TEST
DATA CAPTURE
REGISTER DEMO
VERSION ID
LOGO
EXIT
Figure 14: Test / Demo mode sub-menu
PORT 1 TEST
Sending and Receiving data performance can be analyze
42
PROGRAMMING
under Port 1 test sub menu. To access port 1 test sub menu, place the arrow in front of “PORT 1 TEST” and press and release “SET”. This will take you to the following PORT 1 TEST sub-menu as shown in figure 14.
RECEIVE (RX) TEST
TRANSMIT (TX) TEST
RX/TX TEST
BAUD RATE SCAN
EXIT
Figure 14: Port test 1 sub menu
RECEIVE (RX) TEST
The purpose of this test is to determine that if VSI-Pro receiving the data or not. To test that move the cursor in front of “RECEIVE
(RX) TEST” Receiving data will be appear in three sperate lines, scrolling from right to left. First line is the actual ASCII data coming from the register while last two lines are HEX conversion of ASCII data. If you don not receive any data, check all the connection between VSI-Pro and Register or any additional interfacing device.
TRANSMIT (TX) TEST
The purpose of this test is to determine that if the VSI-Pro able to transmit data or not. To test place arrow in front of “TRANSMIT
(TX) TEST” and press and release if “SET” button. If VSI transmitting data you will see some predefined ASCII character on the screen.
If you don’t see any characters on the screen than check the connection and try again.
Notes: In any of the above test you can stop the scrolling data by holding down either “up” or “down” button.
43
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 1. INTRODUCTION
- 6 2. FEATURES
- 7 3. CONNECTION
- 10 4. PROGRAMMING
- 10 4.1 FRONT CONTROL PANEL
- 12 4.2 GETTING STARTED
- 12 4.3 MAIN PROGRAMMING MENU
- 13 4.3.1 REGISTER SELECT
- 15 4.3.2 SCREEN SETUP
- 19 4.3.3 TEXT DISPLAY
- 23 4.3.4 COMMUNICATION
- 26 4.3.5 EXCEPTION REPORTS
- 37 4.3.6 ALARM OUTPUTS
- 42 4.3.7 TEST/DEMO MODE
- 34 APPENDIX A