null  null
S M A R T P O W E R On-Line UPS
TOWER ON-LINE UPS DOUBLE CONVERSION AND DSP TECHNOLOGY
features
DSP, TRUE DOUBLE CONVERSION UPS
DSP control technology greatly reduces harmonic
distortion in non-liner load bringing high quality
power,ideal for sensitive application.
0.9 HIGH OUTPUT POWER FACTOR
TThe 0.9 output power factor provides higher performance
and efficiency to criticle applications.
HIGH EFFICIENCY MODE (ECO)
Energy-saving, efficiency corrective optimizer (ECO)
mode, allows efficiency up to 96% for more cost
effective UPS system.
INPUT THDi < 5% AND OUTPUT THDv < 2%
Low total harmonic distortion (THD) for low electrical
distortion to provide pure power for sensitive applications
and other critical applications.
Output voltage regulation <1%
Provides quality, stable output power.
FAN SPEED CONTROLLER BASED ON UPS LOAD
Fan automatically turns on based on UPS load and
adjusts speed based on load.
N+X PARALLEL REDUNDANCY
Connect up to 4 units in parallel for redundancy or
capacity.
EXTENDABLE RUNTIME FEATURE
Long back-up time models available for extended run
time and larger charger for critical equipment.
FREQUENCY CONVERTER MODE
Input frequency 50Hz or 60Hz auto sensing, Ouput
frequency that allows to choose 50Hz or 60Hz
independently.
EMERGENCY POWER OFF (EPO)
EPO safety feature allows immediate power down of
UPS and equipment in case of emergency to protect
connected equipment.
RS-232 AND USB PORTS FOR POWER MANAGEMNT SOFTWARE
Easily monitor the current status of the UPS with WinPower,
software for control and monitor multiple UPS.
SNMP SLOT & CARD (OPTIONAL)
SNMP card allows easy monitoring of multiple UPS
control and monitoring through RJ-45 network
connection for remote management, warning
alarms, historic data log, and password security
protection.
www.kenjitsulatam.com
6K/10KVA Front panel & Back panel overview
1
2
3
4
5
1N
2
3
4
5
8
6
7
9
6KVA
1
USB Port
2
EPO
3
Dry Contact Port
4
Intelligent Slot
5
Parallel Port (Optional)
6
Maintenance Switch
7
Input Breaker
8
Fan
9
Terminal Block(Input/Output/Battery)
10KVA
SMART POWER ON-LINE UPS SPECIFICATION
MODEL
CAPACITY
INPUT
Acceptable Input Voltage
Frequency Range
Phase
Power Factor
OUTPUT
Voltage
Current Crest Ratio
Harmonic Distortion
Frequency Range
Output Waveform
Parallel
EFFICIENCY
Line Mode
Battery Mode
ECO Mode
BATTERY
Battery Type
QTY
Backup Time
Recharge Time
Charging Current
Rated Battery Voltage
TRANSFER TIME
Line Mode <-> Battery Mode
INV. <-> BYPASS
ECO -> INV.
INDICATORS
LCD Display
MANAGEMENT
RS-232 / USB Software
Intelligent Slot
EPO
PHYSICAL
Dimension (LxWxH) mm
Net Weight (KG)
SPT-6K
6KVA / 5.4 KW
SPT-10K
10KVA / 9 KW
110 VAC - 276 VAC
50Hz or 60 Hz +/- 5%
single phase with ground
> 0.99 @ full load
220V /208V / 230V(L+N+G), 220V/110V (L1+L2+N+G)
3:1
≤ 2% @ linear load / ≤ 5% @ non-linear load pure sine wave
50 Hz or 60 Hz +/- 5%
pure sine wave
up to 4 units
> 92% @ full load and battery full charged
> 92% @ full load and 12 VDC battery
> 96% @ full load and battery full charged
12V7Ah
20
> 5 mins @ full load
5 hrs charge to 90%
1.2A
240 VDC
12V9Ah
20
0 ms
0 ms
< 10 ms
load level / battery voltage / battery mode / AC mode / bypass mode info
load level / battery voltage / battery mode / AC mode / bypass mode information
SNMP / AS400 / Relay Card
emergency power off
90
260 x 708 x 550
93
To learn more, please contact : [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement