Ablerex - EMI Powertek
Ablerex
Power Abler and Excelsior
Mars Il Parallel
Redundancy On-Line UPS
The Mars || series On-line double conversion UPS with full-time
Digital Signal Processor control technology is the perfect
solution for mission critical users who demand high reliability,
availability and performance from a UPS. Input power factor
correction, high efficiency and parallel redundant capability
provide a superior level of power quality for sensitive electronic
equipment and computer loads.
Simple Parallel Installation
e Full-time Digital Signal Processor Control
* Programmable Frequency Converter
* LCD/LED Mimic Panel
* Smart ECO Mode
* Simple and Easy to Use
* Power Range and Runtime Scalability
* Optional Galvanic Isolation Transformer
* Optional Hot Swappable Battery
* Optional Dual Input Loops
Mars || Parallel
Redundancy On-Line UPS
Using our field proven Digital Signal Processor(DSP) with SMD techniques, the Mars || series UPS achieves high reliability and greater
immunity from utility power problems. The front display panel provides all major systems parameters and operational status of the
UPS that include full diagnostics for simple, easy servicing.
The Mars Il series UPS uses a patented inverter control technology that allows it to achieve N+1 scalable redundant power without the
use of additional components. The Mars II parallel configuration also eliminates any single point of failure.
Simple Parallel Installation
To increase the power capacity or configuring a parallel redundant
UPS system, up to 3 additional Mars II series UPS are simply
interconnected using the CAN-bus RJ45 cables on the rear of the
Mars || series UPS.
Programmable Frequency Converter
The Mars || series UPS may be used as a frequency converter. Simple
programming through the front LCD panel provides the
convenience of 50 or 60Hz.
Intelligent Self-Diagnostics
The Mars Il series UPS with DSP Control, systematically checks each component and displays the result using
on LCD display. This feature allows service technicians the ability to pinpoint and repair the UPS very quickly.
High Input Power Factor and Low Current THD
The Mars ll series UPS provides a ‘clean’ rectifier connection to utility source. It meets today’s industry
standard for energy saving with low reflected harmonic pollution to utility. The Mars Il series UPS achieves
up to 0.99 Input Power Factor as well as <6% Input Current THD.
Energy-efficient UPS
The AC to AC efficiency of the Mars Il series UPS may be up to 90% at 25% load
and higher with larger loadings in normal VFI operation. Using the ECO mode,
an efficiency of up to 97% can be achieved.
Full-time Digital Signal Processor Control
The Mars Il Full Time DSP control system ensures a pure sinewave on the input
and the output of the UPS. The DSP control also provides the user with simple
access to the UPS systems' operational information via the front display panel.
True Double Conversion On-line Technology
The Mars || completely regenerates utility power. It not only corrects and cleans
the utility power, but the VFI(Voltage Frequency Independence) of the Mars Il
complies with the international EN62040-3 standards.
Dual Input Loops
The Mars || series UPS provides single input connections as standard. Optional input terminal connections for
the bypass and rectifier are available. A three-phase input and single phase output option is also available. == ann:
A
*
Tos
LCD/LED Mimic Panel | e +
A precise LCD/LED display provides real time status and parameter readings. These include AC Input and
Output Voltage, Frequency, Battery Voltage, Load Level, UPS temperature, etc. A full size, user-friendly
microprocessor based LCD display, provides advanced monitoring functions and simple operation.
Simple and Easy To Use
The LCD front panel provides direct access to the DSP controller. Changes to the UPS operational modes and
parameters such as output voltage settings, fine adjustments for frequency, bypass voltage settings as well as
alarms status may be easily performed.
Silent Fan Control
The Mars Il series UPS employs variable-speed, forced air cooling fans. These fans will vary in speed
according to the percentage of load. This variable-speed control ensures a low audible noise level
making the Mars Il series UPS suitable for most environments including offices and hospitals.
Emergency Power Off
The Emergency Power Off enables users to remotely shutdown the UPS.
Smart ECO Mode
Energy Saving using ECO mode.
Power Range and Runtime Scalability
The Mars II series UPS provides an excellent return on your investment. The system is fully modular and
allows you to increase the overall power output, battery runtime, and redundancy as your needs and
requirements grow. The modular design eliminates any single point of failure.
Optional Galvanic Isolation Transformer
The Optional Galvanic Transformer provides isolation between the input and the output of the UPS and
various secondary voltage 110/115/120/208/220/230/240Vac.
Maintenance Manual Bypass
The Maintenance Bypass Switch ensures a continuous supply of power to the critical loads during service or periodical maintenance
of the UPS.
Parallel Distribution Box (Rack/Wall Mount Type)
Model Description Dimension (WxHxD)inch'mrm Application
TowPDU-260 Max. 60Arms Max. 2pcs 4.5/6Kva or 1pce 8K/10Kva
TowFDU-2120 Max. 1204rms J40x124x176/17.3x4.9x6.9 Max. 4pcs 4.5/6Kva or 2pcs 8K/10Kva
TowPDLU-2200 Max, 2004rms Max, dps 8K/10Kva
Advanced Battery Discharge Management
The Mars II series UPS automatically manages the End-Discharge voltage of the internal batteries
according to the load. The ABDM function prevents the deep discharge of the batteries during a
power failure.
Cold Start Function
The Mars || series UPS may be powered up without the presence of utility, providing AC power for
immediate power requirements.
Matching Battery Cabinet
Add matching battery cabinets and extend the back up time up to several hours,
Communication Capability
The Mars II series UPS is shipped with
monitoring and shutdown software. The
software allows the control and graceful
shutdown when Utility Power fails
* Remote testing of the major operating
UPS functions.
“ Communicate via SNMP/WEB card.
* Access UPS functions via the WEB.
Optional External Battery Charger
With its isolation conversion technology plus precision control, the optional charger can be
installed inParallel operation up to 4 units. The specifications are as follows:
AC Input Range 100-280Vac, 45-65Hz
Maximum Power Output 10006, continuously
Operation Mode Constant Voltage with Current Limitation
Maximum Parallel Units Up to 4 units
Protections Over-voltage, Against Output Short-Circuit &
Isolated devices for Opposite Polarity Connection
Mounting Mounted on the rear of the UPS or the wall
Dimension (WxHxD, mm/inch) 166x282x86 / 6.6x11.1x3.4
Net Weight (Kgs/lbs) 3.2/7.1
Variety of Customer Options Slots
The Mars || series UPS also provides two additional Customer Options Communication slots in
additional to the standard RS232. An internal 2nd R5232, USB, R5485, Dry Contact, or
WEB/SNMP card provides isolated contacts for industrial and remote alarm applications. The
RS232 will remain active, even with the additional cards installed.
Optional Hot Swappable battery
The Mars || series UPS allows users to easily replace the battery packs without interruption of
the critical load.
Mars || Parallel
Redundancy On-Line UPS
Model MSI4500 M5116000 M5118000 / 8000P M5I/10000 / 10000P
INPUT
Voltage Window | 160-280Vac | 160-280Vac (10) / 277 — 485Vac (30) *
Frequency 45 - 65 Hz
Phase/Wire Single, Line + Neutral + Ground | Single, Line+Neutral+Ground([email protected]); Three, R, 5, T+Neutral+Ground(34}
Power Factor Up to 0.99 at 100% Linear Load
Current THD (100% linear load) <6% **
Voltage Window 200/208/220/230/240Vac Selectable(208/120Vac optional)
Voltage Adjustment Nominal +1%, +2%, +3%, -1%, -2% or -3%
voltage Regulation +2%
Capacity | 4500VA / 3150W 6000VA / 4200W | 8000VA / 5600W | 10000VA / 7000W
Rated Power Factor 0.7 Lagging
Wave Form | Sine Wave, THD<3% (no load to full load)
Frequency Stability | £+0.2% (Free Running)
Frequency Regulation +1Hz; +3Hz
Transfer Time Oms
Crest Factor 3:1
Efficiency(AC to AC, Normal) Up to 90%
Efficiency(AC to AC, ECO) Up to 95%
Autonomy >=12 min. >=8 min. | >=7 min.
DC Start Yes
TYEE SY
Type | Sealed Lead Acid Maintenance Free
Capacity 12V/7AH 12V/9AH
Quantity 20pcs
Voltage 240V dc
SEE Time 4 hours to 90% 5 hours to 90%
Status On LED + LCD | Line Mads, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Bad/Disconnect, Overload, Transferring with interruption & UPS Fault.
Readings on LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature.
Self-Diagnostics | Upon Power-on, Front Panel Setting & Software Control, 24-hour routine checking
ALARMS
Audible and Visual Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions
Overload(w/simulated | Inverter Supply: 105% -150% for 160 seconds ~ 2 cycles before switching bypass.
thermal tripping I-T Curve) Bypass Supply: 105% -200% for 500 seconds ~8 cycles before stopping supply load.
Short Circuit Switch off Immediately
Overheat AC Mode: Switch to Bypass Backup Mode: Switch off the UPS
Battery Low Alarm and Switch Off
Moise Suppression Complies with EN62040-2
Spike Suppression | Complies with EN61000-4-5
Heat — Without Isolated < 450W 10K: <600W
Dissipation Transformer 10KP: <550W
(At Full Linear — With Isolated | < 615W 10K: <1100W
Load)*** Transformer 10KP: <1050W
Leakage Current < 3mA at Full Load
Dimensions | without transformer | 290x645x748/11.4x25.4x29.5
WxDxH(mm/inch) | With transformer 290x645x748/11.4x25.4x29.5 | 290x645x881/11.4x25.4x34.7
Input/Output Connection Hardwire
External Battery Connection Plug-in & Play
Net Weight Standard Unit/Hot 86/112kgs(190/247 Ibs) 8K: B7/113kgs(192/249 Ibs); | 10K: 96/122kgs(215/269 lbs) 10KP:
(without transformer) Swappable unit | | BKP: 92/118kgs(203/260 Ibs) 101/12 7k gs(223/280 Ibs)
Net Weight Standard Unit/Hot 120/146kgs(265/322 Ibs) BK: T40/166kgs(309/366 lbs); | 10K: 149/175kgs{329/386 Ibs) 10KP:
(with transformer) | Swappable unit ВКР: 145/17 1kgs(320/377 Ibs) — | 154/180kgs(340/397 lbs)
ENVIRONMENT
Operating Temperature 0 to 40 C/ 372 to 104 F
Jemperature Weming | This stars) design EEE BAER OO MIETE STE £77 § Amie embate above this rage will stars Gatlery ils
Altitude | 0-2000M/6600ft up to 40 C/104F, 3000M/9900ft up to 35 C/95 F
Humidity 90% RH Maximum, Non-Condensing
Moise <50dB(at 1 Meter/3.3ft)
COMPUTER INTERFACE
Interface Type Standard RS232 Interface
Communication Slots 2nd RS232, USB, R5485, Relay Contact, SNMP/WEE Card, etc.
SAFETY CONFORMANCE
Quality Assurance 1509001 Certified
Safety Standard | EN62040-1-1, UL1778
EMC Standard EN62040-2, EN61000-3-2, EN61000-3-3, FCC Class À
Marks | CE, cUL, UL
Bat.
BET40J0012 12AH
ТАН 1
1
BBT40N0012 12AH Ibs
1
* (160-176Vac for 1-phase input model or 277 -305Vac for 3-phase input model at <75% load)
** 3-phase input model <30% *** reference data
Ablerex Electronics Co., Ltd.
‚ №. 3, Lane 7, Pao Kao Road, ASintien 23114. Talpel Hsien, Taiwa
| win
j
2-2917-5857 Fax +886-2-2912-1705 http/Awww.ablerex. com.tw. Email: [email protected] com.tw
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement