Brad® SST Communication Module for Rockwell

Brad® SST Communication Module for Rockwell
Brad® SST™ backplane communication module connects your Rockwell
ControlLogix® controller to PROFIBUS networks.
Leader for 15 years in connectivity for Rockwell ControlLogix® controllers, Brad® SST™
communication modules are the perfect choice for a wide range of applications including
factory automation, process control and complex machines.
Brad® SST™ PB3 PROFIBUS module connects Rockwell ControlLogix® controller to
PROFIBUS networks. Each module has a communication port that act as PROFIBUSDP Master and/or Slave protocols to exchange data with other PROFIBUS compatible
devices.
Brad® SST™ PB3 module is delivered with its “Add-On-Profile” (AOP) for easy
integration into the ControlLogix® system using the RSLogix 5000 software. The data
transfer from the Brad® SST™ module to the ControlLogix® processor supports 2
modes; a “direct mode” allowing mapping of PROFIBUS data in I/O processor image
(496 input bytes / 496 output bytes) and a “pagging mode” allowing access to 1984
input bytes and 1968 output bytes of PROFIBUS data from user-defined data space set
up into Logix CPU memory.
Brad® SSTTM
Communication Module
for Rockwell
ControlLogix®
112016 PROFIBUS-DP Master/Slave
Save your time, the Brad® SST™ module doesn’t require any ladder logic programming
to be used. The configuration is created using Windows engineering console software
connected via RLL (Remote Link Library) functionality allowing a remote access to the
Brad® SST™ module for the configuration and the diagnostics through Rockwell network
architectures (Ethernet/ControlNet/DeviceNet).
The Brad® SST™ engineering console allows the user to define the network parameters,
PROFIBUS devices and the cyclic data exchanges. The Brad® SST™ software package
includes diagnostic tools to help with the commissioning and monitoring of the
PROFIBUS connection. Thus, the user-friendly tools are available for controlling the
communication in commissioning phase (PROG mode). This same information is also
available in production (RUN mode) through status words making it possible for the user
to manage the execution of the control application in its ladder logic
FEATURES AND BENEFITS
New!
• Advanced Windows engineering • Add-On-Profile!
For increased functionality and configuration and diagnostics console
reduced commissioning time.
• Automatic PROFIBUS devices detection
• Conformal coating module version;
improves and extends the working • Up to 8 Brad® SST™ modules can be life and ensures security and used in one ControlLogix® rack
reliability of performance
• Support local and remote ControlLogix® chassis
• Save money!
No ladder logic to write for
configuration and data transfer
between module and ControlLogix®
processor
• RLL feature: configure and diagnose PROFIBUS network remotely via Rockwell RSLinx
APPLICATIONS
• Control/Command of Modbus devices to perform tasks with strong critical time constraints
• Supervision / Scada to monitor plant
• Bridge Rockwell networks to Modbus compatible devices
Brad ® SST TM Backplane Communication Module
Class 1, Div 2
SPECIFICATIONS
Product Package
Communication Ports
• Engineering Tools
- Configuration console
- Test and diagnostic tools
• 1x PROFIBUS port
- Sub-D, 9-pin, female
- PROFIBUS RS485 with galvanic
insulation (500 V)
- 9.6 Kbps to 12 Mbps
• Supported OS:
- Windows (32-bit): XP, 2000
Technical Data
• Bus interface:
- Rockwell 1756 ControlLogix
- Support multiple modules in a chassis
- Local and remote rack
• Memory:
- 512 MB of onboard shared memory
- 512 MB of flash memory
(user configuration and firmware)
• Diagnostics:
- 4 scrolling characters display
- 3 LEDs indicator:
Health of the network (COMM)
Communication status (SYS)
Initialization complete and module
is ok (OK)
• 1x USB Port:
- Type A, USB 2 and 1.1 compatible
- User configuration boot
- Module firmware upgrade
Brad® SSTTM
Communication Module
for Rockwell
ControlLogix®
112016 PROFIBUS-DP Master/Slave
Protocols
• PROFIBUS DP-V0 Class-1 & Class-2
• PROFIBUS DP-V1 Class-1 & Class-2
• PROFIBUS DP-V0 Slave
Conformances
• CE
• RoHS
• Class 1 / Div 2 - Groups A,B,C & D
Hazardous (Classified) locations
• Rockwell Encompass
Configuration Console
• I/O Mapping:
- Maximum 1984 input bytes
- Maximum 1968 output bytes
- Maximum 250 words status
• Current Consumtion:
- 850 mA @ 5V or 1.75 mA @ 24V
• Operating Temperature: 0 to +60°C
• Storage Temperature: -40 to +85°C
• MTBF: 81.2 years
ORDERING INFORMATION
Order No.
112016-0018
112016-0023
112016-0019
112016-0020
Engineering No.
SST-PB3-CLX-RLL
SST-PB3-CLX-RLL-CC
SST-PB3-CLX-DTM
SST-PB3-CLX-DTS
Description
Brad® SST™ PROFIBUS Scanner for AB ControlLogix, includes RLL
Brad® SST™ PROFIBUS Scanner for AB ControlLogix, coated version, includes RLL
®
Brad SST™ PROFIBUS Scanner for AB ControlLogix, includes RLL and CommDTM driver license
Brad® SST™ CommDTM update driver license for PROFIBUS Scanner
All other products and company names in this datasheet may be trademarks of their registered owners.
www.molex.com
Order No. 987650-5293
Printed in EUR/KG/2011.04
©2011, Molex
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement