Ion Chamber Survey Meter with Beta Slide

Ion Chamber Survey Meter with Beta Slide
Ion Chamber Survey Meter
with Beta Slide
RS
Radiation Safety
Inovision Model 451B
! High sensitivity measurements of
exposure and exposure rate
! Available with dose equivalent
energy response (SI units)
! Fast response to measure radiation
from leakage, scatter beams and
pinholes
! Ergonomic, anti-fatigue handle with
replaceable grip and wrist strap
! Sliding shield for alpha and beta
discrimination
! Excel add-in for Windows® for data
logging and selection of instrument
operating parameters (optional)
! Low noise chamber bias supply for
fast background settling time
! Bright, highly visible colors
! Easy touch keys
Introduction
Features
The Model 451B state-of-the-art ion chamber survey meter is a hand-held battery
operated unit designed for use in both rugged and normal environments. The Model
451B measures alpha, beta, gamma and x-ray radiation. The Model 451B employs
microprocessor and LCD technology and features a rugged ionization chamber with a
mylar window and protective steel mesh. An integral beta shield serves as an equilibrium
thickness for photon measurements. The ergonomic handle, features a large diameter
cushioned grip and is designed to reduce fatigue associated with extended use. The
case is constructed of lightweight, high strength materials and is sealed against moisture.
The user must specify R or Sv when ordering.
• Ideal for a wide range of applications
including NDT, x-ray, and environmental
The display features an analog bar graph, 2.5 digit digital readout, low battery and
freeze mode indicators. User controls consist of an ON/OFF button and a MODE button.
The unit is auto-zeroing and auto-ranging. The display features circuitry that
automatically activates the backlight in low ambient light conditions.
• Battery operated
• Auto-ranging and auto-zeroing
• RS-232 communications interface
• Measures rate and dose simultaneously
• Tripod mount for stationary, area monitor
applications
The RS-232 interface can be connected directly to a computer for use with the Excel
add-in for Windows, enhancing the functionality of the instrument. The software allows
for data retrieval, user parameter selection and provides a virtual instrument display
with audible (requires sound card) and visual alarm indication. The software may be
customized by the user for specific applications.
• Freeze mode indicates peak reading
Applications
• Excel add-in for Windows (optional)
The Model 451B is ideal for site surveys and a wide range of medical and health physics
applications. It is regularly used by Police and Fire Departments, x-ray manufacturers,
government agencies, state inspectors, emergency response and HAZMAT teams, nuclear
medicine labs, hospital radiation safety officers, and nuclear power industry.
• Programmable flashing display and
audible alarm
• Automatic, ultra-bright LCD
Specifications
Radiation detected Alpha above 4 MeV, Beta above 100 keV, and
Gamma above 7 keV
Environmental
Temperature range - 4º to + 158ºF (- 20° to + 70°C)
Operating ranges
Relative humidity 0 to 100%, @ + 60°C
0 to 5 mR/h
or
0 to 50 µSv/h
0 to 50 mR/h
or
0 to 500 µSv/h
0 to 500 mR/h
or
0 to 5 mSv/h
0 to 5 R/h
or
0 to 50 mSv/h
0 to 50 R/h
or
0 to 500 mSv/h
Geotropism Less than 1%
Typical energy dependence
Model 451B typical energy dependence
1.2
1.1
Accuracy Within 10% of reading between 10% and 100% of full scale
indication on any range, exclusive of energy response. Calibration source
is 137Cs
Chamber 349 cc volume air ionization
Chamber wall 246 mg/cm2 thick phenolic
Chamber window 1.7 mg/cm2 mylar, protected by steel mesh,
46 cm2 detection area
0.9
Indicated / Actual
Detector
1
Side
Slide - Closed
0.8
Slide - Open
0.7
0.6
0.5
0.4
Beta slide 440 mg/cm2
0.3
Controls ON/OFF and MODE
0.2
Automatic features Auto-zeroing, auto-ranging, and auto-backlight
Response time
10
100
1000
10000
Effective (keV)
Dimensions 4 (w) x 8 (d) x 6 in (h) (10 x 20 x 15 cm)
Range
Response
0 to 5 mR/h (0 to 50 µSv/h)
8 sec
0 to 50 mR/h (0 to 500 µSv/h)
2.5 sec
0 to 500 mR/h (0 to 5 mSv/h)
2 sec
0 to 5 R/h (0 to 50 mSv/h)
2 sec
0 to 50 R/h (0 to 500 m Sv/h)
2 sec
Power requirements Two 9 V alkaline, 200 hours operation
Warm-up time One minute
Display LCD analog/digital with backlight
Analog 100 element bar graph 6.4 cm long. Bar graph is divided
into 5 major segments, each labeled with the appropriate value for
the range of the instrument
Digital 2.5 digit display is followed by a significant zero digit
depending on the operating range of the instrument. The units of
measurement are indicated on the display at all times. Digits are
0.25 in (6.4 mm) high. Low battery and freeze indicators are also
provided on the display
Modes
Integrate mode Operates continuously 30 seconds after the
instrument has been turned on. Integration is performed even if the
instrument is displaying in mR/h or R/h
Freeze mode Will place a tick mark on the bar graph display to
hold on the peak displayed value. The unit will continue to read
and display current radiation values
Weight 2.5 lb (1.11 kg)
Optional accessories
451 Assistant for Excel (Model 451EXL), includes RS-232
interface cable
Single Unit Carrying Case (Model 190HPS)
Multiple Unit Carrying Case (Model 190HPC)
Check Source, 238Uranium, 0.064 µCi, impregnated 2 x 2 in
yellow card (Model 450UCS)
Available Model(s)
451B-RYR Ion Chamber Survey Meter with Beta Slide and standard
chamber
451B-DE-SI-RYR Ion Chamber Survey Meter with Beta Slide and
dose equivalent chamber
Suffix designation RYR = red/yellow/red
For additional information, please contact Cardinal Health, Radiation
Management Services customer service at 440.248.9300, 800.850.4608, or fax:
440.349.2307; located at 6045 Cochran Road, Cleveland, Ohio 44139-3303, USA.
Tested.
Meets applicable standards.
Specifications are subject to change without notice.
Windows is a registered trademark of Microsoft Corporation.
© Copyright 2003 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.
451B-ds rev 4 26 mar 03
Pressurized µR Ion Chamber
Survey Meter
Inovision Model 451P
RS
Radiation Safety
! High sensitivity µR measurements
of exposure and exposure rate
! Available with dose equivalent
energy response (SI units)
! Fast response to measure radiation
from leakage, scatter beams and
pinholes
! Ergonomic, anti-fatigue handle with
replaceable grip and wrist strap
! Excel add-in for Windows® for data
logging and selection of instrument
operating parameters (optional)
! Low noise chamber bias supply for
fast background reading
! Bright, highly visible colors
! Easy touch keys
Introduction
Features
The Model 451P state-of-the-art ion chamber survey meter is a hand-held battery operated
unit designed for use in both rugged and normal environments. The Model 451P features
a pressurized ionization chamber, providing enhanced sensitivity and improving energy
response to measure gamma and x-ray radiation. The Model 451P employs
microprocessor and LCD technology. The ergonomic handle, features a large diameter
cushioned grip and is designed to reduce fatigue associated with extended use. The
case is constructed of lightweight, high strength materials and is sealed against moisture.
The user must specify R or Sv when ordering.
• Ideal for a wide range of applications
including NDT, x-ray, and environmental
The display features an analog bar graph, 2.5 digit digital readout, low battery and
freeze mode indicators. User controls consist of an ON/OFF button and a MODE button.
The unit is auto-zeroing and auto-ranging. The display features circuitry that
automatically activates the backlight in low ambient light conditions.
• Measures rate and dose simultaneously
The RS-232 interface can be connected directly to a computer for use with the Excel
add-in for Windows, enhancing the functionality of the instrument. The software allows
for data retrieval, user parameter selection and provides a virtual instrument display
with audible (requires sound card) and visual alarm indication. The software may be
customized by the user for specific applications.
Applications
The Model 451P is used in a wide range of medical and health physics applications.
The Model 451P was designed to measure leakage and scatter around diagnostic x-ray
and radiation therapy suites. Also, the Model 451P is ideal for site surveys and is regularly
used by x-ray manufacturers, government agencies, state inspectors, research labs,
biomedical technicians, and in airports for baggage inspection equipment maintenance.
• Battery operated
• Auto-ranging and auto-zeroing
• RS-232 communications interface
• Tripod mount for stationary, area monitor
applications
• Freeze mode indicates peak reading
• Programmable flashing display
• Automatic, ultra-bright LCD display
• Separate integrate mode
• Excel add-in for Windows (optional)
Specifications
0 to 500 µR/h
0 to 5 mR/h
0 to 50 mR/h
0 to 500 mR/h
0 to 5 R/h
or
or
or
or
or
0 to 5 µSv/h
0 to 50 µSv/h
0 to 500 µSv/h
0 to 5 mSv/h
0 to 50 mSv/h
Accuracy Within 10% of reading between 10% and 100% of full scale
indication on any range, exclusive of energy response. Calibration source
is 137Cs
Detector Chamber: 300 cc volume pressurized air ionization chamber
to 8 atmospheres or 125 psi
Controls ON/OFF and MODE
Automatic features Auto-zeroing, auto-ranging, and auto-backlight
Response time Analog response time from 10% to 90% of reading
for a full scale step increase is dependent on operating range. Response
time for a step increase in radiation exposure rate from background:
Step increase,
background to
400 µR/h
4 mR/h
10 mR/h
40 mR/h
100 mR/h
1 R/h
4 R/h
Time to reach 90%
of final value
4.8 sec
3.3 sec
4.3 sec
4.5 sec
2.7 sec
2 sec
2.7 sec
The following table shows time measured from 10% to 90% of final
value for a step increase or decrease in exposure rate such that a range
change does not occur. These values are the response times for the various
ranges:
Range
0 to 500 µR/h (5 µSv/h)
0 to 5 mR/h (50 µSv/h)
0 to 50 mR/h (500 µSv/h)
0 to 500 mR/h (5 mSv/h)
0 to 5 R/h (50 mSv/h)
10% to 90%
5 sec
2 sec
1.8 sec
1.8 sec
1.8 sec
Power requirements Two 9 V alkaline, 200 hours operation
Warm-up time Less than two minutes for initial operation when the
instrument is in equilibrium with ambient temperature
Display LCD analog/digital with backlight
Analog 100 element bar graph 2.5 inch (6.4 cm) long. Bar graph
is divided into five major segments, each labeled with the appropriate
value for the range of the instrument
Digital 2.5 digit display is followed by a significant zero digit
depending on the operating range of the instrument. The units of
measurement are indicated on the display at all times. Digits are
0.25 inches (6.4 mm) high. Low battery and freeze indicators are
also provided on the display
Modes
Integrate mode Operates continuously 30 seconds after the
instrument has been turned on. Integration is performed even if the
instrument is displaying in mR/h or R/h
Freeze mode Will place a tick mark on the bar graph display to
hold on the peak displayed value. The unit will continue to read
and display current radiation values
Environmental
Temperature range - 4º to + 122ºF (- 20° to + 50°C)
Relative humidity 0 to 100%
Geotropism Negligible
Typical energy dependence
16
Nitrogen gamma rays are 110% to 120% of indicated readings as
determined at the University of Lowell
Model 451P typical energy dependence
1.2
1.1
1
0.9
Indicated / Actual
Radiation detected Beta above 1 MeV, Gamma and x-rays above 25 keV
Operating ranges
Side
0.8
Face
0.7
Front
0.6
0.5
0.4
0.3
0.2
10
100
1000
10000
Effective (keV)
Dimensions 4 (w) x 8 (d) x 6 in (h) (10 x 20 x 15 cm)
Weight 2.4 lb (1.07 kg)
Optional accessories
451 Assistant for Excel (Model 451EXL), includes RS-232
interface cable
Single Unit Carrying Case (Model 190HPS)
Multiple Unit Carrying Case (Model 190HPC)
Check Source, 137Cs, 10 µCi. Flat disc, 1 inch diameter
(Model 62-103)
Available model(s)
451P-RYR Pressurized µR Ion Chamber Survey Meter with
standard chamber
451P-DE-SI-RYR Pressurized µR Ion Chamber Survey Meter with
dose equivalent chamber
Suffix designation RYR = red/yellow/red
For additional information, please contact Cardinal Health, Radiation
Management Services customer service at 440.248.9300, 800.850.4608, or fax:
440.349.2307; located at 6045 Cochran Road, Cleveland, Ohio 44139-3303, USA.
Tested.
Meets applicable standards.
Specifications are subject to change without notice.
Windows is a registered trademark of Microsoft Corporation.
© Copyright 2003 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.
451P-ds rev 4 26 mar 03
451 Assistant for Excel
RS
Radiation Safety
Model 451EXL
! Complete remote radiation
information management for Model
451P and 451B Ion Chamber
Survey Meters
! Color-coded data provides quick
identification for radiation levels and
alarm acknowledgment status
Introduction
Features
The 451 Assistant for Excel is an Excel Add-in, a program that adds optional commands and
features to Microsoft® Excel. The 451 Assistant provides remote control for many of the 451
functions, real-time data logging with user defined alarm parameters and a real time virtual
instrument display. The 451 Assistant automatically loads with Excel once it is installed.
The 451 Assistant data logging function automatically records real time measured data in an
active Excel worksheet. Each measurement in the data log is automatically placed in the active
worksheet cell, then the active cell moves down to the next row of cells where it will place the
next set of measured data. Each recorded measurement is time and date stamped. The 451 Assistant
provides user configurable audible and visual alarms for the real time logged data. The picture
and data shows radiation levels above the preset alarm in red, the blue data represents the radiation
level below the alarm that has not been acknowledged. The black data shows when the alarm was
acknowledged. See Control Options for more details.
The 451 Assistant for Excel allows the user to configure the 451’s internal data logging and
alarm settings. It may also be used to download the 451’s internal data log and saves it in an
Excel worksheet where it can be easily graphed for quick trend analysis.
The 451 Assistant provides automatic timed integrated dose measurement over a user defined
integration period or user controlled integrated dose measurement. After the integration timer
has expired or the user has stopped integration, the 451 Assistant retrieves the integrated dose
from the 451 and inserts the integrated dose in the active worksheet cell and the average dose rate
is placed in the next cell to the right.
• Real time data logging in protected
Excel worksheet
Applications
This Model 451EXL information management software program is ideal for the facility Radiation
Safety Officer or anyone responsible for maintaining a permanent record of spills and accidents
for adherence to state and NRC requirements. The remote control of the 451 series of Ion Chambers
may be accessed by any computer on your facility network providing remote information
management.
• Virtual instrument display with audible
and visual alarm indication
• Remote user definable alarm settings
• Downloads 451’s internal data log into
Excel worksheet
• Provides remote control and instrument
configuration
• Complete on-line help speeds learning
• Compatible with Windows® 95, 98,
ME®, NT® 4.0, 2000, XP® and Excel
97, 2000
• Package includes manual, diskette set,
and 25 ft RS-232 cable, Model
1020039000
Specifications
Controls
The 451 Assistant menu and toolbar provide an interface for the user to
remotely control the 451, configure the 451, download the 451’s internal
data log and start / stop real time data logging and integrated dose
measurements
Download Log The 451 is capable of internally logging data at a user
defined interval from 1 to 255 seconds with a total capacity of up to
2700 data points. This feature allows the user to download the 451’s
internal data log into the active Excel worksheet
Options Allows the user to change many properties of the 451 Assistant
for Excel and several of the 451s’ properties. The user may configure
the various visual and audio alarm features of the 451 Assistant for Excel
for each data point that is logged. The 451 Assistant can be configured
to use 2 or 4 alarm states. The four alarm states are acknowledged
normal (below alarm level), unacknowledged normal, acknowledged
alarm and unacknowledged alarm. The user may also select the
communication port used by the 451 (default is COM1). The 451’s
internal data logging parameters and alarm settings may also be changed
from the Options menu
Connect / Disconnect Connects or disconnects the 451 to the
computer’s communication port
Start / Stop Starts and stops computer data logging. When data logging
is started, logged data is placed in the active Excel worksheet and the
worksheet is protected to provide data security
Logging Properties Allows the user specify computer data logging
parameters. The data logging sample interval (2 seconds to 999 hours),
total data logging period (2 seconds to 49 days) and computer data log
alarms may be specified through this menu. These parameters are
independent of the 451’s internal data logging functions
Integrate… Allows the user to select timed integrated dose measurement
or user controlled integrated dose measurement. The user may also
specify the integration period for timed integration from 1 minute to
999 hours. When timed integrate mode is selected, the 451 Assistant
for Excel stops the integrated dose measurement after the specified
integration period has expired
When timed integrate mode is not selected, the user controls the
integration period and the integration time is displayed in real time. The
integrated dose and average dose rate are recorded in the active Excel
worksheet when integration is complete
System requirements
• Windows 95, 98, ME, NT 4.0, 2000, or XP
• Microsoft Excel 97 or 2000
• One serial port (COM1 through COM4)
Available model(s)
451EXL 451 Assistant for Excel
For additional information, please contact Cardinal Health, Radiation
Management Services customer service at 440.248.9300, 800.850.4608, or fax:
440.349.2307; located at 6045 Cochran Road, Cleveland, Ohio 44139-3303, USA.
Specifications are subject to change without notice.
Windows, Windows ME, Windows XP, Windows NT, and Microsoft are registered trademarks of
Microsoft Corporation.
© Copyright 2003 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.
451EXL-ds rev 3 11 mar 03
Low Energy RF Shielded
Survey Meter
RS
Radiation Safety
®
Victoreen Model 440RF/D
! CRT leakage measurement
! Ideal for applications in high RF
fields
! Measures low energy radiation
exposure down to 12 keV
Introduction
Features
The Model 440RF/D Low Energy RF Shielded Survey Meter is a highly sensitive, low
energy, RF shielded survey meter suited for fast, accurate measurements of background
and other low radiation levels. Survey meter design is based on CMOS microprocessor
technology. The Model 440RF/D has Electrical Industrial Association approval and is
designed to meet the radiation sensitivity and measurement geometry requirements for
television receivers set forth by the US Department of HEW. 21 CFR 1020.10 requires
“Radiation exposure rates produced by a television receiver shall not exceed
0.5 milliroentgens per hour at a distance of five centimeters from any point on the
external surface of the receiver,” as measured in accordance with this section.
• Meets 21 CFR 1020.10 Television
Receiver and 21 CFR 1020.40 Cabinet
X-ray Systems requirements for radiation
surveys
• Insensitive to 20 mW/cm2 RF fields
• Resolves 0.02 mR/h from 15 kilovolt
x-rays
• Auto-zeroing
Applications
The Model 440RF/D RF shielded instrument is the basis of measurement for radiation
exposure in the color television industry. This instrument is also used to measure radiation
from radar and transmission towers where RF may be present.
• CMOS design for stability and
performance
• Batteries accessible from outside
instrument
• Available in SI units
Specifications
Radiation detected Beta ray above 150 keV and gamma ray and
x-ray above 12 keV
RF response No response in RF fields up to 20 mW/cm2
440RF/D exposure rate in five overlapping ranges
0 to 1, 0 to 3, 0 to 10, 0 to 30, and 0 to 100 mR/h
440RF/D-SI dose equivalent rate in five overlapping
ranges
0 to 10, 0 to 30, 0 to 100, 0 to 300, and 0 to 1000 µSv/h
Response time 90% of final indication in:
Range
Response
7 sec
7 sec
5 sec
5 sec
5 sec
Temperature range 68º to 104ºF (20° to 40°C)
Relative humidity 0 to 95%, non-condensing
Operating ranges
0 to 1 mR/h (0 to 10 µSv/h)
0 to 3 mR/h (0 to 30 µSv/h)
0 to 10 mR/h (0 to 100 µSv/h)
0 to 30 mR/h (0 to 300 µSv/h)
0 to 100 mR/h (0 to 1000 µSv/h)
Environmental
Pressure dependence Internal software-controlled pressure
transducer and temperature sensor automatically apply standard air
density correction factors from 70 to 106 kPa to the unsealed ion chamber
Initial stabilization Approximately 30 seconds
Detector Internal ionization chamber 3.56 cm diameter by 5.87 cm
long, cross sectional area 10 cm2 volume, with 1.5 mg/cm2 aluminized
mylar window and an external magnesium window 13 mg/cm2 thick.
Center of ion chamber volume is 5 cm from the plane determined by the
tips of three plastic bumpers
Display 3.7 in (9.5 cm) meter scale, marked 0 to 3 and 0 to 10
Power requirements Five 9 V batteries; 200 hours operation. Three
in parallel configuration for electronic supplies and 2 in series
configuration for - 18 V chamber bias
Accuracy Within 10% of reading between 10% and 100% of full scale
indication on any range, exclusive of energy response. Calibration at
21 keV x-ray (27.5 KVCP, 0.9 mmA/HVL)
Controls Single rotary switch for power and range switching and springloaded check source switch
Zero adjust Auto-zeroing
Geotropism Within 2% of full scale in any orientation
Check source Built-in operational uranium check source provides
constancy check of instrument
Typical energy dependence
Housing material All metal, splash-proof
X-ray and gamma ray Within 10% from 12.5 to 42 keV
Dimensions 5 (w) x 8 (d) x 10.8 in (h) (12.7 x 20.3 x 27.6 cm)
Maximum response peak of + 40% at 100 keV. Within 10% at
137
Cs and 60Co with added equilibrium wall
Weight 6.8 lb (3.1 kg)
1.2
Available model(s)
15 kVcp
440RF/D Low Energy RF Shielded Survey Meter
137 Cs
1.0
Correction Factor
(multiply reading by)
27.5 kVcp
0.8
0.6
Shipping volume and weight 2.5 cu ft (0.071 m3) 13.3 lb (6.05 kg)
42.5 kVcp
60 Co
250 kVc p
50 kVcp
100 kVcp
200 kVcp
150 kVc p
with added equilibrium wal l
material in front of window
0.4
0.2
keV
For additional information, please contact Cardinal Health, Radiation
Management Services customer service at 440.248.9300, 800.850.4608, or fax:
440.349.2307; located at 6045 Cochran Road, Cleveland, Ohio 44139-3303, USA.
Tested.
Meets applicable standards.
Specifications are subject to change without notice.
Victoreen is a registered trademark of Cardinal Health, Inc. or one of its subsidiaries.
© Copyright 2003 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.
440RFD-ds rev 3 26 mar 03
Panoramic Survey Meter
®
RS
Radiation Safety
Victoreen Model 470A
! Cutie pie style with tripod for longterm monitoring
Introduction
The Model 470A Panoramic Survey Meter
is designed to be used in and around
medical facilities for many low level
radiation monitoring activities. The Model
470A has a very low energy response
(down to 10 keV). That makes it ideal for
diagnostic x-ray suites, including
mammography. Since this meter can
measure up to 1000 R/h, it is also ideal
for radiotherapy facilities. The Cutie Pie
style of this meter allows it to sit on three
legs for long-term monitoring or to be used
as a hand-held survey meter with the
convenient grip handle.
! Low level radiation monitoring for
diagnostic x-ray and radiotherapy
suites
! Available in SI units
Features
! Measures all energies over 2 pi
solid angle
! Collimator provided for directional
identification
Applications
The Model 470A is popular in health physics instrumentation. Solid state IC technology
is utilized to simplify circuitry, reduce weight and increase reliability. Designed to provide
the user with convenience as well as measurement accuracy, the Model 470A has
numerous applications in the health physics field. Certainly its outstanding features will
suggest many other areas beside diagnostic x-ray and radiotherapy suites where it can
be used to great advantage.
! Twelve overlapping rate ranges
from 3 mR/h to 1000 R/h full scale
! Energy corrected from 8.0 keV to
2.0 MeV
! Integrated exposures from 3 to
1000 mR full scale
Specifications
Radiation detected Alpha above 8 MeV, beta
above 120 keV, gamma and x-ray above 10 keV
Operating ranges
Rate 12 overlapping ranges: 0-3, 10, 30,
100, 300, 1000 mR/h, and R/h
Integrate 6 overlapping ranges: 0 to 3, 10,
30, 100, 300, 1000 mR or 0 to 30, 100 and
300 µSv/h, 0 to 1, 3 and 10 mSv/h; 0 to 30,
100 and 300 mSv/h, 0 and 1, 3 and 10 Sv/h;
0 to 30, 100 and 300 µSv, 0 to 1, 3 and 10 mSv
Accuracy Within 10% of reading between
10% and 100% of full scale indication on
any range, exclusive of energy dependence,
and exclusive of recombination effects at
high rates. Calibrated at 137Cs
Response time 8 sec on 3 mR/h range;
3 sec on 10 mR/h range; 2 sec on 30 mR/h
range; 1.5 sec on 100 and 300 mR/h range
Geotropism Within 2% of full scale any
orientation
Typical energy dependence (Gamma or
x-ray) Within 15% from 10 to 300 keV with
base chamber only. Within 10% from 40 keV
to 2 MeV with equilibrium sleeve
Environmental
Temperature range - 22° to + 122°F (- 30°
to + 50°C) using alkaline batteries below 0°C
Temperature response Within 0.2%/°C
Relative humidity 0 to 99%, noncondensing
Initial stabilization time < 1 minute due to
dielectric absorption
Detector Unsealed air ionization chamber
made of expanded polystyrene with 275 cc vol.
and 17 mg/cm2 wall. Cycolac equilibrium sleeve
and cap, 500 mg/cm2
Display 3.125 in (7.9 cm) taut band meter
Construction Strong, lightweight Cycolac
case
Power requirements Two 1.5 V “D” cell
batteries and four 22.5 V No. 505 batteries
Battery life “D” cell batteries on mR range;
more than 150 hr at 24 hr/day, 210 hr at 8 hr/day
On R/h range, 85 hr at 24 hr/day or 120 hr at
8 hr/day
No. 505 batteries shelf-life (approx. 1 year)
Battery check function built-in
External controls 3 position function switch,
8 position range switch, zero set and adjust knob.
Internal: collecting voltage “check” switch,
coarse zero adjustment, calibration adjustment
Internal controls Collecting voltage “check”
switch, coarse zero adjustment
Dimensions 5.125 (w) x 11 (d) x 9.50 in (h)
(12 x 28 x 24 cm)
Weight 4 lb (1.8 kg) net, 10 lb (4.5 kg) shipping
Check source Natural Uranium mounted on
end cap
Optional accessories
Carrying Case (Model 470-168)
Available model(s)
470A Panoramic Survey Meter
For additional information, please contact Cardinal
Health, Radiation Management Services customer
service at 440.248.9300, 800.850.4608, or fax:
440.349.2307; located at 6045 Cochran Road,
Cleveland, Ohio 44139-3303, USA.
Tested.
Meets applicable standards.
Specifications are subject to change without notice.
Victoreen is a registered trademark of Cardinal Health, Inc. or
one of its subsidiaries. Windows, © Copyright 2003 Cardinal
Health, Inc. or one of its subsidiaries. All rights reserved.
470A-ds rev 2 12 mar 03
Radiation Safety
RS
Gamma Survey Instrument
Calibrator*
Model 64-773
! Eliminates
the
expense,
inconvenience, and work-time lost
when sending such instruments to
an outside calibration service
! Sturdy, easy-to-use
! Safe, accurate calibration
Gamma Survey Instrument Calibrator with one
attenuator removed from radiation path
Introduction
Features
• Self-contained
Gamma Survey Instrument Calibrator with three
attenuators in place
137
Cs source
• Calibrates instruments with ranges up to
2000 mR/hr
• Calibration traceable to NIST
• Attenuators eliminate repositioning for
different scale measurements
• Can be padlocked in closed position for
safety
Specifications
Dimensions 5 (w) x 5 (d) x 8.50 in (h)
(12.7 x 12.7 x 21.6 cm)
Weight 52 lb (23.6 kg)
Available model(s)
64-773 Gamma Survey Instrument Calibrator
* An NRC or Agreement State license is required. When
applying, please designate source as Technical
Operations Model 773. A copy of your license must
accompany the order.
This sturdy, easy-to-use device permits the safe, accurate calibration of instruments used
for surveying gamma radiation. It enables users of dosage-measuring equipment to perform
routine checks at will or as necessary to meet the regulations of the NRC and Agreement
States.
The heavy-duty lead container holds 165 mCi of 137Cs, encapsulated at one end of a control
rod. Since 137Cs has a long half-life (30 years), there is no need to calculate a correction
factor for at least 1 to 2 years after the instrument is shipped.
Applications
The source can be kept in either of two positions: stored or exposed. In the fully-shielded
“stored” position, radiation at the container’s surface is less than 200 mR/hr; at 1 meter
away it is less than 10 mR/hr. In the “exposed” position, the source faces a 36° (horizontal)
x 20° (vertical) port at the shield’s side. The radiation field can be varied by means of three
built-in attenuators (transmission factors 0.25, 0.10, and 0.10). These permit calibration of
three meter scales, each at 20% and 80% of full scale, using only one source-to-meter
distance measurement. The source is moved from “stored” to “exposed” merely by raising
the control rod. For safety, the 137Cs source cannot be removed from its shield, except by the
manufacturer.
A built-in tape measure helps determine the distance from the 137Cs source to the instrument
being calibrated. A padlock (not included) can be used to prevent unauthorized use of the
equipment. A convenient carrying handle is included.
For additional information, please contact Cardinal Health, Radiation Management Services customer
service at 440.248.9300, 800.850.4608, or fax: 440.349.2307; located at 6045 Cochran Road, Cleveland,
Ohio 44139-3303, USA.
Specifications are subject to change without notice.
© Copyright 2003 Cardinal Health, Inc. or one of its subsidiaries. All rights reserved.
64-773-ds rev 2 12 mar 03