c on ne ct i n g t h e p r oc e s s
AS-i general purpose cable
Nonincendive
Field Wiring
& Associated
Apparatus
AS-i cable (PLTC/ITC)
AS-i general purpose cable
Nonincendive Field Wiring
& Associated Apparatus
AS-i cable
(PLTC/ITC) with strut support
Class I, Division 2
AS-i cable (PLTC/ITC) with messenger wire
Control System
Network
120/240 VAC
AS-i cable
(PLTC/ITC)
Class I, Division 1
Rigid metal conduit
Metal clad flexible conduit
JM-3: Potted leads recommended to enable removal of VCT while bus energized
Additional
AS-i length
AS-i cable (PLTC/ITC)
AS-i cable (PLTC/ITC) with messenger wire
Liquidtight flexible conduit
AS-i Cable
(PLTC/ITC) with strut support
AS-i cable
(PLTC/ITC)with strut support
Repeater/
Power Conditioner
120/240 VAC
Level Switches
Rigid metal conduit
30 VDC (PLTC/ITC), no AS-i signal
(distance not included in total AS-i network length)
Protection concepts shown are for illustration purposes. Final acceptance of installation including wiring practices is subject to the authority having jurisdiction.
NEC 500 Wiring Guidelines
Nonincendive Field Wiring and Associated Apparatus
Class I & II, Division 2
Conduit/Cabling:
• General purpose cable
Connections:
• General purpose connectors
• Quick connectors without limitation
Field Instrument Components:
• Drop connectors limit voltage and current into spur
• Field instruments must be nonincendive field wiring apparatus rated with published parameters
(Ci, Li, Vmax, I max)
• Drop Connector and Field Instrument parameters must be coordinated as follows:
Drop Connector
Voc
Isc
<
<
Field Instrument
Vmax
Imax
• Field Instrument Ci and Li must be lower than values determined from ignition curves using 0.9 safety factor
(Ci & Li for drop cable is negligible with length under 20m)
Special Notes:
• Intrinsically safe apparatus may also be used as nonincendive field wiring apparatus
• Instrument wiring may be manipulated while energized
Explosion Proof System
Class I & II, Division 1 & 2
Conduit/Cabling:
• Rigid metal conduit or steel intermediate conduit
• MI (Mineral Insulated, Metal Sheathed) or MC
(Metal Clad) where flexibility required
• Seal-Offs for all enclosures (except those with special ratings)
Connections:
• Fittings must be explosion proof approved
Field Instruments:
• Complete apparatus must be explosion proof rated
Special Notes:
• No seal-offs are required for StoneL JM & Quartz
• Power must be removed before opening enclosures
AS-Interface Wiring Guidelines
Topology: Linear, Star, Tree or Ring (Free Topology)
Field Devices: 31 per network (62 per network with 2.1 Rev and extended addressing)
Cabling: Unshielded, untwisted 2-wire for data and power
(16 AWG is preferred)
Cable Length: 100 meters (328 ft.) per master or
300 meters (984 ft.) with two repeaters
Additional repeaters and cable length may be added in parallel with up to 2 series repeaters
Tray Cabling System
Class I & II, Division 2
Conduit/Cabling:
• Power Limited Tray Cable (PLTC) rated or Instrument
Tray Cable (ITC) rated cable used in cable tray
• PLTC or ITC used as open wiring up to 15m (50 ft) protected by angles, struts or messenger wire and secured at intervals not exceeding 1.8m (6 ft)
• PLTC or ITC used in liquidtight or MC flexible conduit
Connections:
• PLTC and ITC may be connected using compression fittings installed to avoid tensile stress at termination
• Flexible cord and quick connectors suitable provided conditions are met as described for nonincendive equipment
Field Instruments:
• Must be nonincendive equipment rated
Special Notes:
• PLTC power supplies (Class 2 approved) limited to
100 watts with maximum of 60 VDC used to limit energy into the circuit
• ITC power supplies limited to 5 amps and 150 volts rms
Nonincendive Equipment Used in
Explosion Proof & Tray Cabling Systems
Class I & II, Division 2 Only
• Seal-Offs not required
• Liquidtight conduit may be used where flexibility is required
• Field instruments must be nonincendive equipment rated
• Quick connectors may be used with the following provisions:
1. Power removed before plugging and unplugging
2. Current does not exceed 3 amps @ 120VAC
3. Cord is listed for hard usage with receptacle and plug of the locking and grounding type and does not exceed
900mm (3ft)
4. A label is attached to the receptacle warning against uplugging while energized
Special Notes:
• Enclosures may be opened while circuits are energized but wiring may not be manipulated until power is removed.
Legend
General purpose cable
PLTC/ITC in cable tray
PLTC/ITC supported by messenger wire
PLTC/ITC with strut support
Rigid metal conduit or intermediate steel conduit
Metal clad flexible conduit
Liquidtight flexible conduit
Seal fitting
Quick mini connector
Quick mini connector with clasp
Quick micro connector
(general purpose cable)
Compression fitting
S to n e L C or p or a t io n Te leph on e 2 18 -739 -57 74 w w w. s t o n e l . c o m
JM (Junction Module) Series
Clear Cover – use for Class I & II, Div. 2
Aluminum Cover – use for Class I & II,
Div. 1 and 2
• Functions include drop connectors,
I/O modules, relay modules & more
• Connections available with (3) or (4)
1/2" or 3/4" NPT. Specials available with compression fittings or quick connectors
JM-1
JM-2
JMP03_ _ _ _
Protected Drop
Connector* with clear cover
JMS0311C3
Switched Protected
Drop Connector* with clear cover
JM-3
JMS0311E3
Switched Protected
Drop Connector* with aluminum cover
JM-4
JM-5
JM-6
JMX0111C_
Repeater and Power
Conditioner with clear cover
JMM962 _C3
I/O module with pneumatic valve and clear cover
JMM9611CN
I/O module with no pneumatic valve and clear cover
Quartz Series VCTs *
Explosion proof aluminum platform with solid state dual module
Aluminum Cover – use for Class I & II,
Div. 1 and 2
Clear Cover – use for Class I & II, Div. 2
QZ-1
QZP96 [97] E _ _
Aluminum cover
& (2) NPT conduits
QZ-2
FieldBlock Series
Use for Class I & II, Div. 2
• Functions include (4) drop connectors,
I/O modules, relay modules & more
• Connections available with (6) compression fittings, quick connectors or 1/2" NPT conduits. Specials may include from (4) to
(10) connectors and different combinations
FB-1
FBS08009
Switched Protected
Drop Connector* with compression fittings
FB-2
FBP08003
Protected Drop
Connector with quick connectors
Consult StoneL’s FieldLink Bus Networking
Reference Guide for additional products and more information on models and options.
GW
Other FieldLink Products
Gateway -
General Purpose
Models include AS-I to:
• Modbus
• Profibus DP
• DeviceNet
• Ethernet TCP/IP
• Others
PS
FR
PLTC/ITC
AS-i Power Supply -
459015
Class 2 approved for use with ITC/PLTC
Class I Div. 2 wiring.
Power supply may also be located in Class I
Div. 2 areas
FieldRack Enclosures
Rated NEMA 4 & 4X for protecting nonincendive components from process environment in
Class I Div. 2 areas
AS-i Bus Cable -
463002
PLTC & ITC rated for use in Class I
Div. 2 areas. May also be installed in conduit
(Shown yellow in network above for illustration purposes)
* Drop connector provides over voltage and short circuit protection to spur and acts as barrier for nonincendive field wiring and related apparatus
Consult StoneL’s ValvePoint Catalog for additional products and more information on models and options.
Eclipse Series VCTs *
Modular direct namur mount polycarbonate platform with integral proximity sensors
ECG
ECG96 [97] _ _ _
Wired with (2) microconnectors
ECN
ECN96 [97] _ _ _
Integral terminal strip
& (2) NPT conduits
QZP96 [97] C _ _
Clear cover & (2) NPT conduits
Hawkeye Series
Solid state sensor ideal for point sensing
HK
HK_ _ _ _ _
Interface with AS-I
I/O module. Available with 1/2" NPT or quick connectors
Onyx Series VCTs *
Polycarbonate enclosure with integral pneumatic valve and solid state sensors in dual module
ON
ON96 [97] _ _ _ _ _ _
Select brass or stainless steel pneumatic valve
Prism Series
Polycarbonate enclosure with integral pneumatic valve and solid state sensors in dual module adaptable to diaphragm and angle valves
PM
PM96 [97] _ _ _ _ _ _ _
Available with NPT, compression fittings or quick connectors
*VCTs: Valve Communication Terminals
[For extended addressing use function option 97]
© 2004 S ton eL Cor po rat io n PU B # F L- 7 1 3 - 0 9 / 0 4