12

O S C I L L O S C O P E S

:

S E L E C T I O N G U I D E

From student labs to research labs, a scope for every application

Model

54622A

54622D

54624A

54610B

54615B

Repetitive

Bandwidth

100 MHz

Sample

Rate

200 MSa/s

Channels

2

100 MHz 200 MSa/s, 400 MSa/s 2 scope, on logic channels 16 logic

100 MHz 200 MSa/s 4

500 MHz

500 MHz

20 MSa/s

1 GSa/s

2

2

Special Features

Deep memory with high-definition display,

2 MB/ch

View analogue and digital signals simultaneously, with high-definition display, 2 MB/ch

Low-cost 4-channel scope,

2 MB/ch

High bandwidth at a low price

Fast sampling with fast updates

• A full range of scopes for product development, research and education

• Bandwidths to 500 MHz

• Unique Agilent MegaZoom

Deep Memory with patented high-definition displays in the

5462X Series

A new way to see inside your circuits

The new Agilent 54600 Series oscilloscopes

(page 14) provide a unique way to observe and analyse circuit behaviour. With the combination of MegaZoom Deep Memory and nearly twice the horizontal display resolution of any other digital scope, these models highlight important signal features and minimise your troubleshooting time. With configurations offering 2, 4 and 2+16 scope and timing channels, you can choose the right solution for your unique needs.

Page

16

14

16

18

18

O S C I L L O S C O P E S

:

5 4 6 0 0 S E R I E S S C O P E S

The Agilent 54600 scopes

High-definition displays uncover details that you can’t even see on other scopes

NEW

With nearly twice the horizontal resolution of any digital scope on the market, the patented new display technology in the Agilent 54600

Series oscilloscopes opens a new window into circuit behaviour. You’ll see subtle details you couldn’t see before, from narrow transients to distorted edges to intermittent defects, with greater fidelity than you’ve probably ever seen in any digital scope.

By combining this high-definition display with MegaZoom Deep Memory and a signal processing system that’s up to 25 times faster than regular digital scopes, the Agilent 54600

Series of scopes add a unique statistical dimension to your measurements. Each point on the trace is displayed with 32 levels of intensity; the brighter the point, the more samples it represents. This makes it easy to find areas of interest to explore in detail with the pan and zoom features. All of this information is available on a single capture at full speed, with magnifications up to 10,000:1.

The advantage of MegaZoom Deep

Memory

Agilent MegaZoom offers a unique approach to deep memory. It provides signal captures up to 2 million samples on each channel, with higher sustained sample rates and responsive displays. You can find details buried in complex signals, discover anomalies leading up to trigger events and view high- and low-speed signals simultaneously. And unlike traditional deep-memory scopes, MegaZoom is not a special, complicated mode, nor does it slow down the scope. Working in conjunction with the high-definition displays, MegaZoom runs automatically all the time; you'll get the power of deep memory without the drawbacks.

The bright, white dot on the upper display is a distortion in 1 of the 1,500 pulses captured in this single shot measurement. Simply dial in for a closer look using MegaZoom pan and zoom, and you’ll see the details that would have escaped a regular scope, such as the distortion on this square wave.

14

O S C I L L O S C O P E S

:

5 4 6 0 0 S E R I E S S C O P E S

Get unique insights into mixed analogue/digital and MCU-based designs

NEW

View complex circuit operation in ways you’ve never been able to see before, with synchronised scope and timing measurements.

• Designed specifically for debugging mixed analogue/digital and MCU-based systems

• Patented high-definition display works with deep memory to uncover more information about your signals

• Unique 2+16 mixed-signal configuration offers simultaneous scope and logic measurements

The new Agilent 54622D scope solves three of the toughest problems in mixed analogue/digital and MCU-based designs: you can’t see all the signals of interest at once, you can’t find important details, and you can’t see how analogue and digital signals interact. With the 2+16 channel scope/logic configuration, Agilent 2 MB MegaZoom Deep

Memory and a unique high-definition display that highlights areas of interest in your signals, it’s like opening a new window to see inside your circuits.

The exclusive MegaZoom technology enables fast, responsive displays and 2 million samples of memory for every channel. With a single capture, you can collect 10 milliseconds of data and still view 5-nanosecond details using simple pan-and-zoom controls. Plus, powerful cross-domain triggering makes it easier to capture elusive events and conditions.

Built-in triggering for I 2 C buses

If your designs include the Inter-Integrated

Circuit (I 2 C) bus, you'll appreciate the built-in I 2 C triggering in the 54600 Series scopes. They deserialise command words and state conditions for you, taking the work out of setting up triggering.

Agilent 54622D Mixed-Signal Oscilloscope

Scope channels

Bandwidth

Maximum sample rate

Max input (dc + peak ac)

Resolution

Range (per division)

Logic channels

Maximum sample rate

Input level

54622D

2

100 MHz

200 MSa/s

400 V

8 bits

1 mV to 5 V

16

400 MSa/s

±40 V max

500 mVp-p min

Memory

Scope channels

Logic channels

1 pod active

2 pods active

Timebase (per division)

Triggering

Peak detect

Measurements

Waveform maths

Storage

2 MB/ch

8 MB/ch

4 MB/ch

5 ns to 50 s

Edge, pulse width, pattern, TV, sequence, I 2 C, duration

5 ns

Vp-p, Vavg, Vrms, frequency, period, pulse width, rise/fall time

Multiplication, subtraction, FFT, integration, differentiation

Built-in floppy disk

Connectivity

Built-in Help

Parallel, RS-232 standard; GPIB optional*

In 9 languages

Warranty 3 years standard, optional increase to 5 years

Ordering information

54622D 100 MHz 2 +16 mixed analogue and digital oscilloscope

N2727A integrated Seiko thermal printer and pouch

N2757A GPIB interface module for 54621A/D, 54622A/D, 54624A scopes

1183A testmobile scope cart

1185A carrying case

1186A rack mount kit

N2726A accessory pouch and front panel cover

* BenchLink XL software and RS-232 cable included free with 54622D

See page 33 for GPIB and RS-232 cable needs.

14

O S C I L L O S C O P E S

:

5 4 6 0 0 S E R I E S S C O P E S

Get unique insights into mixed analogue/digital and MCU-based designs

NEW

View complex circuit operation in ways you’ve never been able to see before, with synchronised scope and timing measurements.

• Designed specifically for debugging mixed analogue/digital and MCU-based systems

• Patented high-definition display works with deep memory to uncover more information about your signals

• Unique 2+16 mixed-signal configuration offers simultaneous scope and logic measurements

The new Agilent 54622D scope solves three of the toughest problems in mixed analogue/digital and MCU-based designs: you can’t see all the signals of interest at once, you can’t find important details, and you can’t see how analogue and digital signals interact. With the 2+16 channel scope/logic configuration, Agilent 2 MB MegaZoom Deep

Memory and a unique high-definition display that highlights areas of interest in your signals, it’s like opening a new window to see inside your circuits.

The exclusive MegaZoom technology enables fast, responsive displays and 2 million samples of memory for every channel. With a single capture, you can collect 10 milliseconds of data and still view 5-nanosecond details using simple pan-and-zoom controls. Plus, powerful cross-domain triggering makes it easier to capture elusive events and conditions.

Built-in triggering for I 2 C buses

If your designs include the Inter-Integrated

Circuit (I 2 C) bus, you'll appreciate the built-in I 2 C triggering in the 54600 Series scopes. They deserialise command words and state conditions for you, taking the work out of setting up triggering.

Agilent 54622D Mixed-Signal Oscilloscope

Scope channels

Bandwidth

Maximum sample rate

Max input (dc + peak ac)

Resolution

Range (per division)

Logic channels

Maximum sample rate

Input level

54622D

2

100 MHz

200 MSa/s

400 V

8 bits

1 mV to 5 V

16

400 MSa/s

±40 V max

500 mVp-p min

Memory

Scope channels

Logic channels

1 pod active

2 pods active

Timebase (per division)

Triggering

Peak detect

Measurements

Waveform maths

Storage

2 MB/ch

8 MB/ch

4 MB/ch

5 ns to 50 s

Edge, pulse width, pattern, TV, sequence, I 2 C, duration

5 ns

Vp-p, Vavg, Vrms, frequency, period, pulse width, rise/fall time

Multiplication, subtraction, FFT, integration, differentiation

Built-in floppy disk

Connectivity

Built-in Help

Parallel, RS-232 standard; GPIB optional*

In 9 languages

Warranty 3 years standard, optional increase to 5 years

Ordering information

54622D 100 MHz 2 +16 mixed analogue and digital oscilloscope

N2727A integrated Seiko thermal printer and pouch

N2757A GPIB interface module for 54621A/D, 54622A/D, 54624A scopes

1183A testmobile scope cart

1185A carrying case

1186A rack mount kit

N2726A accessory pouch and front panel cover

* BenchLink XL software and RS-232 cable included free with 54622D

See page 33 for GPIB and RS-232 cable needs.

16

O S C I L L O S C O P E S

:

5 4 6 0 0 S E R I E S S C O P E S

Choose a scope configuration for your specific troubleshooting needs

NEW

Need more channels for complex analogue designs? Check out the four-channel,

100 MHz Agilent 54624A.

• Choose two or four channels

• Exclusive combination of

Deep Memory and high-definition displays find more details buried in your signals

• Advanced troubleshooting power at value prices

Get the advantage of MegaZoom and high-definition displays with your choice of configurations. The Agilent 54622A is a good choice for field service and production test. For troubleshooting complex analogue circuits, the

54624A offers 100 MHz bandwidth on four channels. All combine quick, easy operation with the responsive displays that are vital to efficient design characterisation and troubleshooting.

All models also offer the exclusive combination of Agilent MegaZoom Deep Memory and new high-definition displays that help you extract more informatio from your signals.

With a two-million-sample memory on each channel, the 54622A/24A let you capture long signals at full bandwidth, then pan and zoom through the data to find the details. Plus, the operation is so easy and responsive, you won’t even know you’re using a deep-memory scope.

Page 13 offers more detail on this unique troubleshooting capability.

Among the many quality probes and connectors you can add to your Agilent scopes, be sure to check out the new N2772A 20 MHz differential probe on page 32.

Agilent 54622A and 54624A Oscilloscopes

54622A

Input channels

Bandwidth

2

Sample rate

Max input (dc + peak ac)

Resolution

100 MHz

200 MSa/s

400 V

8 bits

54624A

4

Range (per division)

Memory

Timebase (per division)

Triggering

Peak detect

Measurements

Waveform maths

Storage

1 mV to 5 V

2 MB/ch

5 ns to 50 s

Edge, pulse width, pattern, TV, sequence, I 2

5 ns

C, duration

Vp-p, Vavg, Vrms, frequency, period, pulse width, rise/fall time

Multiplication, subtraction, FFT, integration, differentiation

Built-in floppy disk

Connectivity

Built-in help

Parallel, RS-232 standard; GPIB optional*

In 9 languages

Warranty 3 years standard, optional increase to 5 years

Ordering information

54622A 2-channel 100 MHz oscilloscope

54624A 4-channel 100 MHz oscilloscope

N2727A integrated Seiko thermal printer and pouch

N2757A GPIB interface module for 54622A/D, 54624A scopes

1183A testmobile scope cart

1185A carrying case

1186A rack mount kit

N2726A accessory pouch and front panel cover (standard with 100 MHz models)

* BenchLink XL software and RS-232 cable included free with 54622A and 54624A

See page 33 for GPIB and RS-232 cable needs.

Finding the details buried in complex signals

Agilent 54600

Series Scopes

It’s a classic troubleshooting problem: you know there’s a problem buried somewhere deep inside a long, complex signal, but your scope can’t find it. If you don’t know what the problem looks like, you probably can’t set a trigger to catch it. And if you slow down the timebase to catch a longer portion of the signal, chances are the glitch will fall in between samples.

That’s just the sort of problem Agilent

MegaZoom and the 54600 high-definition displays were designed to solve. You can capture up to 2 million samples on every channel at full bandwidth, check for intensity indications on the 32-level greyscale display, then zoom in on the highlighted data to find the problem.

16

O S C I L L O S C O P E S

:

5 4 6 0 0 S E R I E S S C O P E S

Choose a scope configuration for your specific troubleshooting needs

NEW

Need more channels for complex analogue designs? Check out the four-channel,

100 MHz Agilent 54624A.

• Choose two or four channels

• Exclusive combination of

Deep Memory and high-definition displays find more details buried in your signals

• Advanced troubleshooting power at value prices

Get the advantage of MegaZoom and high-definition displays with your choice of configurations. The Agilent 54622A is a good choice for field service and production test. For troubleshooting complex analogue circuits, the

54624A offers 100 MHz bandwidth on four channels. All combine quick, easy operation with the responsive displays that are vital to efficient design characterisation and troubleshooting.

All models also offer the exclusive combination of Agilent MegaZoom Deep Memory and new high-definition displays that help you extract more informatio from your signals.

With a two-million-sample memory on each channel, the 54622A/24A let you capture long signals at full bandwidth, then pan and zoom through the data to find the details. Plus, the operation is so easy and responsive, you won’t even know you’re using a deep-memory scope.

Page 13 offers more detail on this unique troubleshooting capability.

Among the many quality probes and connectors you can add to your Agilent scopes, be sure to check out the new N2772A 20 MHz differential probe on page 32.

Agilent 54622A and 54624A Oscilloscopes

54622A

Input channels

Bandwidth

2

Sample rate

Max input (dc + peak ac)

Resolution

100 MHz

200 MSa/s

400 V

8 bits

54624A

4

Range (per division)

Memory

Timebase (per division)

Triggering

Peak detect

Measurements

Waveform maths

Storage

1 mV to 5 V

2 MB/ch

5 ns to 50 s

Edge, pulse width, pattern, TV, sequence, I 2

5 ns

C, duration

Vp-p, Vavg, Vrms, frequency, period, pulse width, rise/fall time

Multiplication, subtraction, FFT, integration, differentiation

Built-in floppy disk

Connectivity

Built-in help

Parallel, RS-232 standard; GPIB optional*

In 9 languages

Warranty 3 years standard, optional increase to 5 years

Ordering information

54622A 2-channel 100 MHz oscilloscope

54624A 4-channel 100 MHz oscilloscope

N2727A integrated Seiko thermal printer and pouch

N2757A GPIB interface module for 54622A/D, 54624A scopes

1183A testmobile scope cart

1185A carrying case

1186A rack mount kit

N2726A accessory pouch and front panel cover (standard with 100 MHz models)

* BenchLink XL software and RS-232 cable included free with 54622A and 54624A

See page 33 for GPIB and RS-232 cable needs.

Finding the details buried in complex signals

Agilent 54600

Series Scopes

It’s a classic troubleshooting problem: you know there’s a problem buried somewhere deep inside a long, complex signal, but your scope can’t find it. If you don’t know what the problem looks like, you probably can’t set a trigger to catch it. And if you slow down the timebase to catch a longer portion of the signal, chances are the glitch will fall in between samples.

That’s just the sort of problem Agilent

MegaZoom and the 54600 high-definition displays were designed to solve. You can capture up to 2 million samples on every channel at full bandwidth, check for intensity indications on the 32-level greyscale display, then zoom in on the highlighted data to find the problem.

18

O S C I L L O S C O P E S

:

5 4 6 0 0 S C O P E S

Agilent’s 500 MHz scopes

The high-speed answer for low-speed budgets

With single-shot bandwidths as high as

500 MHz, you’ll see those important details on high-speed dynamic signals.

• The industry’s lowest-cost

500 MHz scope

• Single-shot bandwidths as high as 500 MHz and sample rates up to 2 GSa/s

• 1 ns peak detect at all sweep speeds

When you need bandwidth for demanding applications but your budget will not accommodate a high-end research scope, the

500 MHz scopes in the Agilent 54610 Series may be just what you need.

The Agilent 54610B is the lowest-priced

500 MHz scope on the market, but it doesn’t compromise performance or measurement quality. You’ll still get ±0.01% horizontal accuracy and a maximum display update rate of 1.5 million points per second.

The Agilent 54615B boosts the sampling rate to 1 GSa/s while preserving the intuitive analogue feel and instantaneous response of the other 54600 scopes. With horizontal accuracy of ±0.005% and horizontal resolution of 20 ps, you’ll uncover the details that hide from slower scopes.

Speaking of sample rate, many scopes offer good sample rate performance at fast sweep speeds but run into trouble as you slow the sweep down. No matter how slowly you sweep the 54615B, it can still detect glitches as narrow as 1 ns when utilising peak detect.

Agilent 54610B and 54615B Oscilloscopes

54610B 54615B

Bandwidth

Ch 1 & 2 ac coupled

Single-shot bandwidth

Number of channels

Maximum sample rate single shot

Record length (maximum) single shot

Max. display update rate

Peak detect

Sensitivity

Ch 1 & 2 dc gain accuracy

Rise time (calculated)

Ch 1 & 2

Input impedance dc–500 MHz

10 Hz–500 MHz dc–2 MHz

2

20 MSa/s

4,000 points

2,000 points

1,500,000 points/s

50 ns

2 mV/div to 5 V/div

±2% dc–500 MHz

10 Hz–500 MHz

250 MHz

2

1 GSa/s

5,000 points

5,000 points

500,000 points/s

1 ns

2 mV/div to 5 V/div

±2%

<700 ps

1 M

, approx. 9 pF or 50

Ω selectable

<700 ps

1 M

, approx. 9 pF or 50

Ω selectable

Input coupling

Ch 1 & 2

Maximum input (dc + peak ac)

Timebase range (main & delayed)

Trigger sources

Horizontal accuracy

Horizontal resolution

Trigger sensitivity dc to 25 MHz dc to max. bandwidth

Resolution

Power

Weight

Size (excl. handle)

Warranty dc, ac or ground

250 V or 5 Vrms in 50

Ω mode

1 ns/div to 5 s/div

Ch 1, 2, line, or ext.

±0.01%

25 ps dc, ac or ground

250 V or 5 Vrms in 50

Ω mode

1 ns/div to 5 s/div

Ch 1, 2, line, or ext.

±0.005%

20 ps

0.35 div or 3.5 mV [1]

1 div or 10 mV [2]

0.5 div or 5.0 mV [1]

1 div or 10 mV [2]

8 bits

Voltage: 100–240 Vac, 45–440 Hz, 300 VA maximum

Approx. 6.2 kg

172 mm H x 322 mm W x 317 mm D

3 years

Ordering information

54610B 2 channel 500 MHz oscilloscope

54615B 2 channel 500 MHz oscilloscope

Opt. 005 enhanced TV/video triggering (54610B/15B/16B/C)

Opt. 101 10098A accessory pouch and front panel cover

Opt. 103 54654A operator’s training kit

54600 Scopes Interface and Enhancement Modules

Ordering information

Opt. 104 1185A carrying case

Opt. 1CM 1186A rack mount kit

1141A differential probe

Note: The 1142A power module is required for use with the 54610B oscilloscope

1183A testmobile

Product Description

1.

54650A GPIB interface module

54652B RS-232 & parallel interface module

2.

54657A GPIB measurement/storage module

54659B RS-232 measurement/storage module

3.

E2657A measurement/connectivity kit for GPIB

E2659A measurement/connectivity kit for RS-232

FFT BenchLink XL BenchLink

GPIB RS-232 Parallel Advanced Software Scope

Meas.

(free) Software

[1] Trigger sensitivity from dc to 100 MHz.

[2] Trigger sensitivity from 100 MHz to max. bandwidth.

See page 33 for GPIB and RS-232 cable needs.

34810B BenchLink Scope software for Windows

Windows ®

® is available separately. See page 34.

is a U.S. registered trademark of Microsoft Corporation.

• •

Catching elusive glitches

Agilent 54600 Scopes (500 MHz)

Signal transients can often be difficult to detect, especially on slower sweep speeds, but peak detect can help capture those elusive glitches.

The shortage of high-speed memory in most digital scopes means they have to reduce sample rates on all but the fastest sweeps. The slower the sampling, the greater the chance that a glitch will hit in between samples. In other words, those impressive sampling specifications don’t mean much in many measurement scenarios.

Digital peak detect in the 500 MHz 54600 scopes solves this problem by recording maximum and minimum levels between samples, catching glitches as narrow as 1 ns—at all sweep speeds. You can sweep as slowly as 5 s/div, knowing that the scope will detect troublesome glitches.

18

O S C I L L O S C O P E S

:

5 4 6 0 0 S C O P E S

Agilent’s 500 MHz scopes

The high-speed answer for low-speed budgets

With single-shot bandwidths as high as

500 MHz, you’ll see those important details on high-speed dynamic signals.

• The industry’s lowest-cost

500 MHz scope

• Single-shot bandwidths as high as 500 MHz and sample rates up to 2 GSa/s

• 1 ns peak detect at all sweep speeds

When you need bandwidth for demanding applications but your budget will not accommodate a high-end research scope, the

500 MHz scopes in the Agilent 54610 Series may be just what you need.

The Agilent 54610B is the lowest-priced

500 MHz scope on the market, but it doesn’t compromise performance or measurement quality. You’ll still get ±0.01% horizontal accuracy and a maximum display update rate of 1.5 million points per second.

The Agilent 54615B boosts the sampling rate to 1 GSa/s while preserving the intuitive analogue feel and instantaneous response of the other 54600 scopes. With horizontal accuracy of ±0.005% and horizontal resolution of 20 ps, you’ll uncover the details that hide from slower scopes.

Speaking of sample rate, many scopes offer good sample rate performance at fast sweep speeds but run into trouble as you slow the sweep down. No matter how slowly you sweep the 54615B, it can still detect glitches as narrow as 1 ns when utilising peak detect.

Agilent 54610B and 54615B Oscilloscopes

54610B 54615B

Bandwidth

Ch 1 & 2 ac coupled

Single-shot bandwidth

Number of channels

Maximum sample rate single shot

Record length (maximum) single shot

Max. display update rate

Peak detect

Sensitivity

Ch 1 & 2 dc gain accuracy

Rise time (calculated)

Ch 1 & 2

Input impedance dc–500 MHz

10 Hz–500 MHz dc–2 MHz

2

20 MSa/s

4,000 points

2,000 points

1,500,000 points/s

50 ns

2 mV/div to 5 V/div

±2% dc–500 MHz

10 Hz–500 MHz

250 MHz

2

1 GSa/s

5,000 points

5,000 points

500,000 points/s

1 ns

2 mV/div to 5 V/div

±2%

<700 ps

1 M

, approx. 9 pF or 50

Ω selectable

<700 ps

1 M

, approx. 9 pF or 50

Ω selectable

Input coupling

Ch 1 & 2

Maximum input (dc + peak ac)

Timebase range (main & delayed)

Trigger sources

Horizontal accuracy

Horizontal resolution

Trigger sensitivity dc to 25 MHz dc to max. bandwidth

Resolution

Power

Weight

Size (excl. handle)

Warranty dc, ac or ground

250 V or 5 Vrms in 50

Ω mode

1 ns/div to 5 s/div

Ch 1, 2, line, or ext.

±0.01%

25 ps dc, ac or ground

250 V or 5 Vrms in 50

Ω mode

1 ns/div to 5 s/div

Ch 1, 2, line, or ext.

±0.005%

20 ps

0.35 div or 3.5 mV [1]

1 div or 10 mV [2]

0.5 div or 5.0 mV [1]

1 div or 10 mV [2]

8 bits

Voltage: 100–240 Vac, 45–440 Hz, 300 VA maximum

Approx. 6.2 kg

172 mm H x 322 mm W x 317 mm D

3 years

Ordering information

54610B 2 channel 500 MHz oscilloscope

54615B 2 channel 500 MHz oscilloscope

Opt. 005 enhanced TV/video triggering (54610B/15B/16B/C)

Opt. 101 10098A accessory pouch and front panel cover

Opt. 103 54654A operator’s training kit

54600 Scopes Interface and Enhancement Modules

Ordering information

Opt. 104 1185A carrying case

Opt. 1CM 1186A rack mount kit

1141A differential probe

Note: The 1142A power module is required for use with the 54610B oscilloscope

1183A testmobile

Product Description

1.

54650A GPIB interface module

54652B RS-232 & parallel interface module

2.

54657A GPIB measurement/storage module

54659B RS-232 measurement/storage module

3.

E2657A measurement/connectivity kit for GPIB

E2659A measurement/connectivity kit for RS-232

FFT BenchLink XL BenchLink

GPIB RS-232 Parallel Advanced Software Scope

Meas.

(free) Software

[1] Trigger sensitivity from dc to 100 MHz.

[2] Trigger sensitivity from 100 MHz to max. bandwidth.

See page 33 for GPIB and RS-232 cable needs.

34810B BenchLink Scope software for Windows

Windows ®

® is available separately. See page 34.

is a U.S. registered trademark of Microsoft Corporation.

• •

Catching elusive glitches

Agilent 54600 Scopes (500 MHz)

Signal transients can often be difficult to detect, especially on slower sweep speeds, but peak detect can help capture those elusive glitches.

The shortage of high-speed memory in most digital scopes means they have to reduce sample rates on all but the fastest sweeps. The slower the sampling, the greater the chance that a glitch will hit in between samples. In other words, those impressive sampling specifications don’t mean much in many measurement scenarios.

Digital peak detect in the 500 MHz 54600 scopes solves this problem by recording maximum and minimum levels between samples, catching glitches as narrow as 1 ns—at all sweep speeds. You can sweep as slowly as 5 s/div, knowing that the scope will detect troublesome glitches.

32

O S C I L L O S C O P E S :

P R O B E S A N D

I C C O N N E C T I V I T Y

Are your measurements getting off to a good start?

A.

B.

I.

A. N2771A 30 kV probe

B. 1146A current probe

C. N2772A differential probe

D. 10075A 0.5 mm IC probing kit

E. Wedge probe adapter

F. 10072A pitch probing kit with

10074C passive probe

G. 10076A high-voltage probe

H. 10074C passive probe

I. N2727A printer kit

H.

C.

E.

D.

F.

G.

Passive probes (A, F, G, H)

The Agilent 10070 Series passive probes create quality connections with Agilent scopes. For high-voltage measurements, the N2771A accommodates up to 30 kV.

Differential probe (C)

Use the Agilent N2772A differential probe with any 54600 Series scope to safely measure floating circuits. With 20 MHz bandwidth and switchable attenuations of

20:1 and 200:1, this versatile probe covers a wide range of applications, including high-voltage circuits.

Current probe (B)

The Agilent 1146A ac/dc current probe accurately measures currents from 100 mA to

100 Arms, from dc to 100 kHz, without needing to make an electrical connection to the circuit.

Wedge probe adapter (E)

Probe fine-pitch devices safely with the Wedge probe adapter, a unique, mechanically

§non-invasive way to connect to 0.5 and

0.65 mm ICs—three, eight or 16 pins at a time.

Printer kit (I)

The Agilent N2727A printer kit provides everything you need for easy documentation directly from your 5462X scope.

Ordering information

Model Description

1146A

10070C

10072A

10074C

10075A

10076A

E2613B

E2614A

E2643A

E2615B

E2616A

E2644A current probe, ac/dc, 100 mA to 100 Arms, dc to 100 kHz passive probe, 20 MHz, 1:1, 1 M

Ω input impedance pitch probing kit with 10074C passive probe passive probe shipped with scope, 150 MHz, 10:1, 10 M

Ω input impedance

0.5 mm IC probing kit passive probe, high voltage, 250 MHz, 100:1, 66.7 M

Ω input impedance

Wedge probe adapter, 3 signals, 0.5 mm IC leg spacing

Wedge probe adapter, 8 signals, 0.5 mm IC leg spacing

Wedge probe adapter, 16 signals, 0.5 mm IC leg spacing

Wedge probe adapter, 3 signals, 0.65 mm IC leg spacing

Wedge probe adapter, 8 signals, 0.65 mm IC leg spacing

Wedge probe adapter, 16 signals, 0.65 mm IC leg spacing

N2727A

N2771A

N2772A integrated Seiko thermal printer for 5462X scopes passive probe, high voltage, 50 MHz, 1000:1, 100 M

Ω input impedance differential probe, high voltage, 20 MHz, 20:1 or 200:1

Pub ID 10326-ENG

Rev 01

32

O S C I L L O S C O P E S :

P R O B E S A N D

I C C O N N E C T I V I T Y

Are your measurements getting off to a good start?

A.

B.

I.

A. N2771A 30 kV probe

B. 1146A current probe

C. N2772A differential probe

D. 10075A 0.5 mm IC probing kit

E. Wedge probe adapter

F. 10072A pitch probing kit with

10074C passive probe

G. 10076A high-voltage probe

H. 10074C passive probe

I. N2727A printer kit

H.

C.

E.

D.

F.

G.

Passive probes (A, F, G, H)

The Agilent 10070 Series passive probes create quality connections with Agilent scopes. For high-voltage measurements, the N2771A accommodates up to 30 kV.

Differential probe (C)

Use the Agilent N2772A differential probe with any 54600 Series scope to safely measure floating circuits. With 20 MHz bandwidth and switchable attenuations of

20:1 and 200:1, this versatile probe covers a wide range of applications, including high-voltage circuits.

Current probe (B)

The Agilent 1146A ac/dc current probe accurately measures currents from 100 mA to

100 Arms, from dc to 100 kHz, without needing to make an electrical connection to the circuit.

Wedge probe adapter (E)

Probe fine-pitch devices safely with the Wedge probe adapter, a unique, mechanically

§non-invasive way to connect to 0.5 and

0.65 mm ICs—three, eight or 16 pins at a time.

Printer kit (I)

The Agilent N2727A printer kit provides everything you need for easy documentation directly from your 5462X scope.

Ordering information

Model Description

1146A

10070C

10072A

10074C

10075A

10076A

E2613B

E2614A

E2643A

E2615B

E2616A

E2644A current probe, ac/dc, 100 mA to 100 Arms, dc to 100 kHz passive probe, 20 MHz, 1:1, 1 M

Ω input impedance pitch probing kit with 10074C passive probe passive probe shipped with scope, 150 MHz, 10:1, 10 M

Ω input impedance

0.5 mm IC probing kit passive probe, high voltage, 250 MHz, 100:1, 66.7 M

Ω input impedance

Wedge probe adapter, 3 signals, 0.5 mm IC leg spacing

Wedge probe adapter, 8 signals, 0.5 mm IC leg spacing

Wedge probe adapter, 16 signals, 0.5 mm IC leg spacing

Wedge probe adapter, 3 signals, 0.65 mm IC leg spacing

Wedge probe adapter, 8 signals, 0.65 mm IC leg spacing

Wedge probe adapter, 16 signals, 0.65 mm IC leg spacing

N2727A

N2771A

N2772A integrated Seiko thermal printer for 5462X scopes passive probe, high voltage, 50 MHz, 1000:1, 100 M

Ω input impedance differential probe, high voltage, 20 MHz, 20:1 or 200:1