Instructions for Installation - Glow-worm

Instructions for Installation - Glow-worm

The energy you need

Instructions for

Installation

Climapro

1

1

RF

EN

TABLE OF CONTENTS

INTRODUCTION

2 CE .............................................................................................................. 3

INSTALLER

3 Climapro

1

3.1

installation .......................................................................................... 3

List of contents ........................................................................................... 3

........................................................................................................ 3 room

4.2 Wireless

INSTALLER MENU

6

7

Accessing the installer menu ............................................................................... 6

Returning to the user menu .................................................................................. 6

8.2 Tree

8.3 functions

.............................................................................................. 7

Summary of menus and functions available .................................................. 8

8.4 Compatibility

MAINTENANCE

9 Trouble-shooting................................................................................................. 9

9.1 Fault

9.2 Resetting the room thermostat ...................................................................10

TECHNICAL DATA

10 Climapro

1

..........................................................................................................11

11 Climapro

1

RF ......................................................................................................11

- 2 -

INTRODUCTION

INTRODUCTION

3.2 Fixing

3.2.1 Wired room thermostat

The instructions are an integral part of the

Climapro

1

RF and must be handed to the user on completion of the installation in order to comply with the current regulation.

• Carefully read the manual, to enable safe installation, use and servicing. No liability can be accepted in the event of damage for not complying with the guidance in this instruction manual.

3.2.2 Wireless room thermostat

The CE mark indicates that the units described in this manual are in compliance with the following directives:

- European Directive Num. 2004-108 of the European Parliament and the Council regarding electromagnetic compatibility

- European Directive Num. 2006-95 of the

European Parliament and the Council regarding low voltage

- Directive regarding telecommunications equipment ( Directive R & TTE 99/5/ EEC of the Council of the European Community)

INSTALLER

3 Climapro

1

installation

3.1 List of contents

Climapro

1

programmable room thermostat

Wall support for the Climapro

1

(*)

Radio receiver

AA LR6 "alkaline batteries" (*)

(*) delivered with the wireless version

(x1)

(x1)

(x1)

(x4)

radio receiver on control box unit

2

1

2

Key

1 Control box unit

2 Radio receiver

Slide the radio receiver into the notches.

i

IMPORTANT:

It is easier to pass the EBUS cable if the pre-cut part is removed.

EN

0020140263_00 - 11/11 - Glow-worm

- 3 -

INSTALLER

A

B

1

radio receiver outside appliance

3

2

1

Key

1 Radio receiver

2 Fixing

3 Drilling screw

Key

1 Pre-cut part of the electrical box

radio receiver in the control box unit

A

B

2

1 e

DANGER:

Incorrect installation can cause electric shock or damage to the equipment.

The electrical connection must be made only by a qualifi ed engineer.

b

Do not connect the room thermostat to a 230V terminal.

N

230 V

RT L FP 2

EN

230

V

Key

1 Control box unit

2 Radio receiver i

IMPORTANT:

The receiver should be installed outside the appliance if the appliance control box does not have a location for the radio receiver.

i

IMPORTANT:

Do not remove the link (RT 24V) from the room thermostat connection on the boiler main pcb.

Use a connecting cable that complies with the technical specifi cations (refer to the technical data chapter). i

IMPORTANT:

The location of the EBUS terminal block varies according to the heating system.

It is always identifi ed by having «BUS» written on it.

- 4 -

0020140263_00 - 11/11 - Glow-worm

4.1 Wired room thermostat

connected to a boiler

A

INSTALLER

4.2 Wireless room thermostat

connected to a boiler

A

24 V

BUS

RT 24V

BUS

T° ext

RT

24 V

AQ

BUS

230

B

B1 B2

Key

A connection on the room thermostat:

B connection to the EBUS 24V terminal on the boiler

(examples B1 & B2)

connected to Smart Wiring Centre 2

B

A

EBUS

+

1

-

2

Key

A connection on the room thermostat:

B connection to the EBUS 24V terminal on the control box

24 V BUS

RT 24V

BUS

T° ext

RT

24 V

AQ

BUS

B

230

B1 B2

Key

A connection on the radio receiver:

B connection to the EBUS 24V terminal on the boiler

(examples B1 & B2)

connected to Systempro

The radio receiver function is integrated into the Systempro. There is no electrical connection to be made in an installation including a

Systempro.

5 Commissioning

• Switch on the appliances that make up the installation (see the installation manuals).

If using the Climapro

1

RF, remove the insulating tab in the room thermostat battery compartment.

• Follow the instructions given by the installation assistant.

• Make the adjustments and select the necessary options depending on the installation.

Finalise the installation in the installer menu.

Check that these main settings are compatible with the installation.

Check the installation by issuing a heating demand.

EN

0020140263_00 - 11/11 - Glow-worm

- 5 -

EN

INSTALLER MENU

INSTALLER MENU

6 Accessing the installer menu

The installation menu is still accessible after commissioning.

• Press the button for 7 seconds .

• Enter the installer access code (96).

7 Returning to the user menu

• Press the button for 3 seconds to return to the main user screen.

The installer menu customises itself depending on the appliance it is connected to and the connection method.

Automatic heating curve

(if an outdoor sensor is connected)

The automatic heating curve function continually seeks the most suitable value to ensure your comfort and the effi ciency of your heating system. The optimum value is obtained approximately 24 hours after the system is started. It is recommended that you activate this function. If the function is deactivated, the heating curve can be set manually by the installer.

Thermostat function

(if an outside sensor is connected)

The heating system alters the water temperature in the heating circuit depending on: the ambient temperature, the outside temperature.

If this function is deactivated, the heating system no longer takes into account the ambient temperature. The heating system uses just the outside temperature.

Anticipation

The heating system anticipates the fi rst programmed setting change in the morning.

This function allows it to reach the programmed temperature rapidly (the function is available and independent for each zone).

Performance index

The performance indicator is calculated from the effi ciency of all appliances over the last 24 hours.

The cursor moves along a scale graduated.

Service reminder

This function reminds the end user to service the appliance. The user must plan the maintenance of their system.

The date must be entered into the installer menu during installation and after each maintenance.

The icon « » is displayed on the room thermostat screen 30 days before the date entered into the installer menu.

- 6 -

0020140263_00 - 11/11 - Glow-worm

INSTALLER MENU

Heating

INSTALLER

Hot water

MENU

FUNCTIONS

AVAILABLE

Outdoor sensor

Modulating control

Room T° function

Anticipation

Maximum room T°

Room T° correction

Activate/deactivate the function

Maximum T°

Activate/deactivate the programme

Recirculation (**)

Cooling

Option

Activate/deactivate the function

Activate/deactivate the programme

Effi ciency info

Auto time date/time

Language

Phone

Service indicator

About

Radio *

Connexion

Radio test

(*) extra menu in wireless connection mode.

(**) Not applicable for Glow-worm automatic heating curve management correct the measured outdoor temperature manually set the heating curve

Heating

Maximum room T°

Room T° correction

Modulating control

Room T° function

Anticipation

Main settings

Program

Maximum T°

30°C

0°C on on off

Domestic hot water

On/Off on off

60°C off Recirculation (**)

Cooling

On/Off

Program if an outdoor sensor is connected

Automatic heating curve

Correct the outdoor temperature

Settings

Effi ciency info

Auto time

Service indicator off off on

0°C off on off

EN

0020140263_00 - 11/11 - Glow-worm

- 7 -

EN

INSTALLER MENU

8.3 Summary of menus and functions available

Climapro

1

can be the master or secondary room thermostat:

Master

- The “master” room thermostat of the installation has all functions available. The installation comprises only one main room thermostat. It is in general in the principal part of the dwelling (zone 1).

Secondary

- The “secondary” room thermostat located in another part has a limited number of functions.

8.4 Compatibility of the room thermostat

Room thermostat version wired wireless

Appliance Systempro

-

Smart wiring center 2

-

Menus and functions

( = available depending on the associated appliance and the status of the thermostat)

Boiler master

Heating

Auto heating curve

Modulating control

Room T° function

Anticipation

Max. ambient temp.

Ambient temp. correction

Hot water

Activate/deactivate the function

Activate/deactivate the programme

Maximum T°

Recirculation

Cooling

Activate/deactivate the function

Activate/deactivate the programme

Options

Effi ciency info

Auto time

Date/time

Language

Service indicator

About

Radio

Connection

Radio test

- 8 -

-

-

-

The room thermostat is connected to:

Systempro control unit

¨Smart wiring centre 2¨ control unit the status of the room thermostat is: master secondary master secondary

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

0020140263_00 - 11/11 - Glow-worm

-

-

-

-

-

-

-

-

-

-

MAINTENANCE

9 Trouble-shooting

The following checks should be performed before proceeding onto specifi c diagnostics

• Check the error messages in the room temperature thermostat’s display zone

9.1.1 Wired room thermostat i

IMPORTANT:

If the room thermostat becomes disconnected from the boiler, the heating system uses its own operational settings. Check that these settings are compatible with the installation.

Cause

No display on screen

The ambient temperature does not reach the programmed temperature.

The ambient temperature exceeds the programmed temperature.

The installation assistant is not displayed during the

Commissioning.

Solution

Check that there is no power cut.

Check that:

- the boiler is properly connected and switched on,

- the wiring centre is properly connected and switched on,

Check that the thermostat valves on the radiators are fully open.

Check that:

- The setting of the outside sensor heating curve is suitable for the installation,

- the setting of the max. heating outlet temperature is suitable for the installation.

Reset the room thermostat.

See chapter "Reinitialisation of the room thermostat".

MAINTENANCE

9.1.2 Wireless room thermostat i

IMPORTANT:

The settings are recorded in the room thermostat and the wireless receiver.

i

IMPORTANT:

If the wireless receiver becomes disconnected from the boiler, the heating system uses its own operational settings.

Check that these settings are compatible with the installation.

Cause

No display on screen

The ambient temperature exceeds the programmed temperature.

Solution

Check that the room thermostat is not in standby mode.

Check that there is no power cut.

Check that:

- the boiler is properly connected and switched on,

- The room thermostat batteries are properly installed in their compartment

- The battery polarity is not reversed

- The batteries are not exhausted. If so, replace with new batteries.

The ambient temperature does not reach the programmed temperature.

Check that the thermostat valves on the radiators are fully open.

Check that:

- The setting of the outside sensor heating curve is suitable for the installation,

- the setting of the max. heating outlet temperature is suitable for the installation.

EN

0020140263_00 - 11/11 - Glow-worm

- 9 -

MAINTENANCE

EN

i

IMPORTANT:

Faults described in this chapter should be rectifi ed by a qualifi ed engineer and if needed by the After Sales Service.

5

3

2

4

1

Key

1 Radio receiver

2 Cover for radio receiver

3 Red LED

4 Radio receiver circuit board

5 Green LED

In the event of a problem:

• Remove the cover (2) from the radio receiver

(1) to see the 2 LEDs.

• Check the state of the 2 LEDs (green (5) and red (3) located on the electronic board (4) in the radio receiver.

Radio receiver

Green LED off

Red LED off

Cause Solution

-Failure of electrical supply

- Defective EBUS connection cable

Ensure that there is no interruption to the electricity supply and that the appliance is properly connected and turned on.

• Check the electrical connection between the receiver and the appliance.

Radio receiver

Red LED switched on

Cause Solution

- Appliance fault

- Radio signal transmission error

- EBUS communications error

- Defective radio transmitter or receiver

- EBUS connecting cable defective

• Check that:

- The appliances functioning status is correct

- The room thermostat batteries are properly installed in their compartment - The battery polarity is not reversed

- The batteries are not exhausted. If so, replace with new batteries.

• Check the electrical connection between the receiver and the appliance.

• Check the radio communication between the thermostat and the receiver.

9.2 Resetting the room thermostat

This function is used to return the room thermostat to factory settings.

This restarts the installation assistant.

b

The resetting of factory settings is irreversible. All customised confi guration of the room thermostat will be lost.

• Simultaneously press the buttons

for 10 seconds.

• Confi rm by pressing .

- 10 -

0020140263_00 - 11/11 - Glow-worm

TECHNICAL DATA

10 Climapro

1

Description

Room temperature authorized in the room where the control is installed

Maximum authorised temperature of domestic water

Power-supply voltage EBUS

Electrical connection cable section

Max. length of electric connection cables

Electrical protection

Pollution rating

Dimensions:

Height

Width

Depth

Unit Climaplus RF

°C 50

°C

V 24 mm² 2 x 0.75

m

65

300

IP20

2 mm 97 mm 146.5

mm 35

MAINTENANCE

11 Climapro

1

RF

Description

Room temperature authorized in the room where the control is installed

Maximum authorised temperature of domestic water

Power-supply voltage EBUS

Electrical connection cable section

Max. length of electric connection cables

Transmission/reception frequency

Electrical protection

Pollution rating

Frequency of communication with outdoor sensor

Frequency of communication with the control box

Average unobstructed working range (*)

Average range within the home

(*)

Thermostat dimensions:

Unit

°C

°C

V mm² m

MHz min min m m

Climaplus

50

65

24

2 x 0.75

300

868

IP20

2

15

10

100

25

Height

Width

Depth

Wireless receiver dimensions:

Height mm mm mm

115

146.5

41 mm 20

Width

Depth mm mm

171

58

(*) Can vary according to installation conditions and electromagnetic environment

0020140263_00 - 11/11 - Glow-worm

- 11 -

EN

GLOW-WORM

Nottingham Road,

Belper, Derbyshire.

DE56 1JT

www.glow-worm.co.uk

Because of our constant endeavour for improvement, details may vary slightly from those shown in these instructions.

The energy you need

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project