Model 8710
Wireless Thermostat
Owner’s Manual
Includes
Operating Instructions and
Warranty Information
READ AND SAVE THESE INSTRUCTIONS
Improved Comfort
Your wireless thermostat provides automatic control of
the temperature. You can set separate temperatures
for heating and cooling for four time periods per day
(morning, daytime, evening and night). Or you can
operate the thermostat without using the schedule
feature (Permanent Hold mode).
Energy Savings
The schedule feature can save you energy by reducing
the heating and cooling at night and during the daytime
when you are away.
Table of contents
Thermostat Overview . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Factory Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Selecting System
(OFF, AUTO, HEAT, COOL or EM HT) . . . . . . . . . . . . . . . 4
Selecting Fan
(AUTO or CONT) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Thermostat Overview
Indicates Morn, Day,
Eve or Night schedule
Space temperature
Heat
Set To
Selecting Schedule or Permanent Hold . . . . . . . . . . . . 5
Inside
AUTO
Setting the Heating and Cooling Temperature . . . . . . . 6
Setting the Time and Day . . . . . . . . . . . . . . . . . . . . . . . 6
Changing the Schedule . . . . . . . . . . . . . . . . . . . . . . . . . 7
Indicates the Schedule,
Hold or Permanent
Hold mode
Low Battery Indication . . . . . . . . . . . . . . . . . . . . . . . . 10
Limited warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Warranty registration . . . . . . . . . . . . . . . . . . . . . . . . . 11
Schedule
Mo
HOLD
Menu key used to
set time of day, daily
schedule, calibrate
temperature sensor
and display schedule
Hold key used to switch
between Schedule and
Permanent H operation
SYSTEM
Day
FAN
AM
MENU
Reviewing the Time and Temperature Schedule . . . . . 9
2
Up and Down keys
used when adjusting
temperature, time of
day, day of the week,
program start times
and other options
Temperature Setting
NEXT
ENTER
SYSTEM key selects
Heat, Cool, Auto
Heat/Cool, Off and
Emergency Heating for
a heat pump application
Fan key selects Auto
or Cont fan operation
Battery compartment,
2 AA batteries
Next key used when
setting time of day
and schedules
Enter key used when
setting time of day and
schedules
3
Selecting System
Factory Schedule
Off, Auto, Heat, Cool or EM HT
The thermostat is shipped with the following factory
schedule.
Program
Start Time
Morning
Setpoint
Heating
Cooling
6:00AM
70F
78F
Day
8:00AM
62F
82F
Evening
5:00PM
70F
78F
Night
10:00PM
62F
82F
Auto or Cont
Press the SYSTEM key to select OFF, AUTO (heating
and cooling), HEAT (heating), COOL (cooling) or EM HT
(emergency heating if your system is a heat pump).
In AUTO the thermostat will call for heating or cooling
based on the heating and cooling set temperatures and
the indoor temperature. To view both the heating and
cooling set temperature in Auto mode, press and hold
the NEXT key. The LCD will display Heat Set To and
then Cool Set To along with with the corresponding set
temperature. Use the Up and Down keys to change the
set temperature when the proper mode is displayed.
WARNING
Heat
Set To
The thermostat is battery powered and the
batteries should be changed every year or
when the low battery warning is displayed.
Inside
HEAT
Th
AM
MENU
4
Selecting FAN
HOLD
NEXT
AUTO
ENTER
Press the FAN key to select AUTO or CONT
(continuous) fan operation. In AUTO the thermostat
activates the fan during heating and cooling calls. In
CONT the fan runs continuously to circulate air.
FAN
MODE
When in Schedule operation, adjusting the heating
or cooling temperature using the Up and Down
keys switches to the Hold mode. After 3 hours the
thermostat returns to the Schedule mode. Press the
HOLD key at any time to return to the Schedule mode.
The Hold Permanent mode maintains the heating
and cooling temperatures indefinitely until the HOLD
key is pressed which will return the thermostat to the
Schedule operation.
Set To
Inside
Heat
Set To
HEAT
Inside
SCHEDULE
MODE IN
DAY
SCHEDULE
HEAT
Th
SYSTEM
MODE
AM
MENU
HOLD
NEXT
AUTO
Schedule
Day
Selecting SCHEDULE OR
PERMANENT HOLD
Th
AUTO
AM
ENTER
MENU
HOLD
NEXT
ENTER
HOLD KEY
Press the HOLD key to switch between Hold, Hold
Permanent and Schedule. Schedule operation
automatically changes the heating and cooling
temperature settings at the four scheduled times –
Morning, Day, Evening and Night.
5
Setting the heating and
cooling temperature
Setting the Time and Day
Press the Up or Down key to change the heating or
cooling temperature. Press the NEXT key to switch
between the heating and cooling temperature.
Cool
Set To
Inside
HEAT
Schedule
Day
Th
SCHEDULE
MODE IN
DAY
SCHEDULE
To set the time of day and the day of the week, press
the MENU key and the LCD will display the hour. Use
the Up and Down keys to set the hour. Make sure that
the AM or PM is correct.
HOLD
Press the MENU key twice until the LCD displays the
schedule screen shown below with the current day
of the week. Press and hold the Up or Down key to
change the morning (Morn) schedule start time.
Press the NEXT key to set the minute. Use the Up and
Down keys to set the minute.
Schedule Morn
CANCEL
Th
Schedule Morn
ENTER
NEXT
Press the NEXT key to display the morning Cooling
(Cool) temperature. Use the Up or Down keys to
change the temperature.
AUTO
NEXT
Heat
Set To
AM
Press the NEXT key to set the current day of the week.
Use the Up and Down keys to select the day of the
week and press the ENTER key.
AM
MENU
Changing the Schedule
Th
AM
NEXT KEY
MENU
AM
6
NEXT
Set To
NEXT
Press the NEXT key to display the morning heating
(Heat) temperature. Use the Up or Down keys to
change the temperature.
Th
CANCEL
CANCEL
Cool
Schedule Morn
Th
ENTER
AM
CANCEL
NEXT
7
Continue using the NEXT key and the Up and Down
keys to set the start time, heating temperature and
cooling temperature for the Day, Evening and Night
schedules. After the Night schedule is completed, you
can press the ENTER key which will only save the
schedule for the current day, or you can apply the same
schedule to other days of the week by pressing the
NEXT key.
Mo (Monday) will appear on the LCD. Continue to press
the NEXT key to add additional days of the week. Use
the Up and Down keys to turn days ON or OFF. The
schedule will be applied to the days that are ON. These
days will be displayed on the thermostat. The example
below shows a schedule being applied to Monday
through Friday.
Reviewing the Time and
Temperature Schedule
Press the MENU key 4 times until the first schedule
is displayed as shown below. The display will show
the Monday morning scheduled start time and heating
temperature setting.
Schedule Morn
Sa Su
AM
CANCEL
Schedule
Schedule
Mo
CANCEL
8
Night
PM
NEXT
Mo Tu We Th Fr
CANCEL
ENTER
PM
NEXT
Night
ENTER
Pressing the ENTER key will copy and save the
schedule for the days of the week selected. After the
ENTER key is pressed, the thermostat will return to
normal operation To change the schedule for other days
of the week, repeat the same programming steps.
NEXT
Heat
Set To
ENTER
After the Night schedule is completed, press the next
key and Mo (Monday) will appear on the LCD. Continue
to press the NEXT key and use the Up and Down keys
to turn days ON or OFF. The schedule will be applied
to the days that are ON. In the example above, Sa
(Saturday) and Su (Sunday) have been selected. To save
the schedule, press the ENTER key and the thermostat
will resume normal operation. Each day of the week can
have a separate schedule if required. Just program the
schedule and select the day then press the ENTER key.
Schedule Morn
Mo
AM
CANCEL
NEXT
Continuing pressing the NEXT key to display the
morning, day, evening and night schedule along with the
heating and cooling temperatures for each day of the
week. Press the CANCEL key at any time to exit and
return the thermostat to normal operation.
9
THERMOSTAT FIVE YEAR LIMITED WARRANTY
Low Battery Indication
If the battery voltage drops to where it could interfere
with reliable operation, the LCD will alternately
display Lo in place of the inside temperature.
Replace batteries as soon as possible. There is
approximately one month of operation left.
Heat
Set To
Inside
AUTO
Schedule
Day
Th
Warranty Registration
AM
MENU
HOLD
NEXT
Your Research Products Corporation Aprilaire® Thermostat unit is expressly warranted for five (5) years from date of installation to be free from
defects in materials or workmanship.
Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat
which is found to be defective within such five (5) year period and which is returned, together with the date of installation, no later than thirty
(30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701.
THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN
WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF.
IMPLIED WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID
FIVE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN
DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED
WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT
INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A
QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION.
Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages,
so the above exclusions or limitations may not apply to you.
This warranty gives you specific legal rights and you may also have other rights which vary from state to state.
This equipment if installed in strict accordance with the manufacturer’s instructions, complies with the limits for a Class B computing device
pursuant to Subpart J of Part 15 of FCC Rules.
ENTER
Please…Take a few minutes to visit us on-line at www.aprilaire.com to register your Aprilaire product.
If you do not have on-line access, please mail a postcard with your name, address, phone number, product purchased
and date of purchase to: Research Products Corporation, P.O. BOX 1467, Madison, WI 53701
Your Warranty Registration information will not be sold or shared outside of this company.
10
11
P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357
www.aprilaire.com
61000829 10.11
B2205617A
© 2011 Aprilaire – A division of Research Products Corporation

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement