- No category
advertisement
Mitsubishi FX Driver
© 2016 PTC Inc. All Rights Reserved.
Mitsubishi FX Driver
Table of Contents
Mitsubishi FX Driver
Table of Contents
Mitsubishi FX Driver
Overview
Setup
Channel Properties
Channel Properties - Serial Communications
Channel Properties - Write Optimizations
Device Properties
Device Properties - Auto-Demotion
Device Properties - Redundancy
Modem Setup
Data Types Description
Address Descriptions
FX Addressing
FX0 Addressing
FX0N Addressing
FX2N Addressing
FX3U Addressing
Event Log Messages
Received block length does not match expected length. | Received block length = <number>,
Expected block length = <number>.
Appendix: Ethernet Encapsulation Examples
Index
2
www. kepware.com
3
Mitsubishi FX Driver
Mitsubishi FX Driver
Help version 1.034
CONTENTS
Overview
What is the Mitsubishi FX Driver?
Device Setup
How do I configure a device for use with this driver?
Data Types Description
What data types does this driver support?
Address Descriptions
How do I address a data location on a Mitsubishi FX series device?
Error Descriptions
What messages does the Mitsubishi FX Driver produce?
Overview
The Mitsubishi FX Driver provides a reliable way to connect Mitsubishi FX devices to OPC client applications; including HMI, SCADA, Historian, MES, ERP, and countless custom applications. It is intended for use with
Mitsubishi FX series devices.
www. kepware.com
Mitsubishi FX Driver
Setup
Supported Device Models
FX
FX0
FX0N
FX2N
FX3U
Note: FX3U is not supported in Windows CE.
Communication Protocol
Direct Serial
Supported Communication Parameters
Baud Rate: 9600
Parity: Even
Data Bits: 7
Stop Bits: 1
Ethernet Encapsulation
This driver supports Ethernet Encapsulation, which allows the driver to communicate with serial devices attached to an Ethernet network using a terminal server. It may be invoked through the COM ID dialog in
Channel Properties. For more information, refer to the OPC server's help file.
When used directly with a serial port, this driver supports only a single connection to a single controller per serial port. When operating in the Ethernet Encapsulation mode, the driver supports up to 100 controllers per channel. In this mode, a single controller can be paired with a terminal server (device server) to form a single node. For more information, refer to
Appendix: Ethernet Encapsulation Examples
Note: Ethernet Encapsulation is not supported by the FX3U model.
Maximum Number of Channels and Devices
The maximum number of channels supported by this driver is 256. The maximum number of devices per channel is 100.
Device IDs
This protocol does not support simultaneous communication with multiple devices.
Flow Control
When using an RS232/RS485 converter, the type of flow control required depends on the needs of the converter. Some converters do not require any flow control whereas others require RTS flow. Consult the converter's documentation in order to determine its flow requirements. An RS485 converter that provides automatic flow control is recommended.
Note: When using the manufacturer's supplied communications cable, it is sometimes necessary to choose a flow control setting of RTS or RTS Always in the channel properties.
Channel Properties
Device Properties
4
www. kepware.com
5
Mitsubishi FX Driver
Channel Properties
This server supports the use of simultaneous multiple communications drivers. Each protocol or driver used in a server project is called a channel. A server project may consist of many channels with the same communications driver or with unique communications drivers. A channel acts as the basic building block of an OPC link.
The properties associated with a channel are broken in to logical groupings. While some groups are specific to a given driver or protocol, the following are the common groups:
General
Ethernet
or
Serial Communications
Write Optimization
Advanced
Channel Properties - General
This server supports the use of simultaneous multiple communications drivers. Each protocol or driver used in a server project is called a channel. A server project may consist of many channels with the same communications driver or with unique communications drivers. A channel acts as the basic building block of an OPC link. This group is used to specify general channel properties, such as the identification attributes and operating mode.
Identification
Name: User-defined identity of this channel. In each server project, each channel name must be unique.
Although names can be up to 256 characters, some client applications have a limited display window when browsing the OPC server's tag space. The channel name is part of the OPC browser information.
For information on reserved characters, refer to "How To... Properly Name a Channel, Device, Tag, and Tag
Group" in the server help.
Description: User-defined information about this channel.
Many of these properties, including Description, have an associated system tag.
Driver: Selected protocol / driver for this channel. This property specifies the device driver that was selected during channel creation. It is a disabled setting in the channel properties.
Note: With the server's online full-time operation, these properties can be changed at any time. This includes changing the channel name to prevent clients from registering data with the server. If a client has already acquired an item from the server before the channel name is changed, the items are unaffected. If, after the channel name has been changed, the client application releases the item and attempts to reacquire using the old channel name, the item is not accepted. With this in mind, changes to the properties should not be made once a large client application has been developed. Utilize the User Manager to prevent operators from changing properties and restrict access rights to server features.
www. kepware.com
Mitsubishi FX Driver
Diagnostics
Diagnostics Capture: When enabled, this option makes the channel's diagnostic information available to
OPC applications. Because the server's diagnostic features require a minimal amount of overhead processing, it is recommended that they be utilized when needed and disabled when not. The default is disabled.
For more information, refer to "Communication Diagnostics" in the server help.
Not all drivers support diagnostics. To determine whether diagnostics are available for a particular driver, open the driver information and locate the "Supports device level diagnostics" statement.
Channel Properties - Serial Communications
Serial communication properties are available to serial drivers and vary depending on the driver, connection type, and options selected. Below is a superset of the possible properties.
Click to jump to one of the sections:
or
, and
.
Note: With the server's online full-time operation, these properties can be changed at any time. Utilize the User Manager to restrict access rights to server features, as changes made to these properties can temporarily disrupt communications.
6
Connection Type
Physical Medium: Choose the type of hardware device for data communications. Options include
COM Port, None, Modem, and Ethernet Encapsulation. The default is COM Port.
l l
None: Select None to indicate there is no physical connection, which displays the
section.
COM Port: Select Com Port to display and configure the
section.
l
Modem: Select Modem if phone lines are used for communications, which are configured in the
section.
l
Ethernet Encap.: Select if Ethernet Encapsulation is used for communications, which displays the
section.
l
Shared: Verify the connection is correctly identified as sharing the current configuration with another channel. This is a read-only property.
www. kepware.com
7
Mitsubishi FX Driver
Serial Port Settings
COM ID: Specify the Communications ID to be used when communicating with devices assigned to the channel. The valid range is 1 to 9991 to 16. The default is 1.
Baud Rate: Specify the baud rate to be used to configure the selected communications port.
Data Bits: Specify the number of data bits per data word. Options include 5, 6, 7, or 8.
Parity: Specify the type of parity for the data. Options include Odd, Even, or None.
Stop Bits: Specify the number of stop bits per data word. Options include 1 or 2.
Flow Control: Select how the RTS and DTR control lines are utilized. Flow control is required to communicate with some serial devices. Options are: l
None: This option does not toggle or assert control lines.
l l l
DTR: This option asserts the DTR line when the communications port is opened and remains on.
RTS: This option specifies that the RTS line is high if bytes are available for transmission. After all buffered bytes have been sent, the RTS line is low. This is normally used with RS232/RS485 converter hardware.
RTS, DTR: This option is a combination of DTR and RTS.
l
RTS Always: This option asserts the RTS line when the communication port is opened and remains on.
l
RTS Manual: This option asserts the RTS line based on the timing properties entered for RTS Line
Control. It is only available when the driver supports manual RTS line control (or when the properties are shared and at least one of the channels belongs to a driver that provides this support).
RTS Manual adds an RTS Line Control property with options as follows: l
Raise: This property specifies the amount of time that the RTS line is raised prior to data transmission. The valid range is 0 to 9999 milliseconds. The default is 10 milliseconds.
l
Drop: This property specifies the amount of time that the RTS line remains high after data transmission. The valid range is 0 to 9999 milliseconds. The default is 10 milliseconds.
l
Poll Delay: This property specifies the amount of time that polling for communications is delayed. The valid range is 0 to 9999. The default is 10 milliseconds.
Tip: When using two-wire RS-485, "echoes" may occur on the communication lines. Since this communication does not support echo suppression, it is recommended that echoes be disabled or a RS-485 converter be used.
Operational Behavior
l
Report Comm. Errors: Enable or disable reporting of low-level communications errors. When enabled, low-level errors are posted to the Event Log as they occur. When disabled, these same errors are not posted even though normal request failures are. The default is Enable.
l
Close Idle Connection: Choose to close the connection when there are no longer any tags being referenced by a client on the channel. The default is Enable.
l
Idle Time to Close: Specify the amount of time that the server waits once all tags have been removed before closing the COM port. The default is 15 seconds.
Ethernet Settings
www. kepware.com
Mitsubishi FX Driver
Ethernet Encapsulation provides communication with serial devices connected to terminal servers on the
Ethernet network. A terminal server is essentially a virtual serial port that converts TCP/IP messages on the
Ethernet network to serial data. Once the message has been converted, users can connect standard devices that support serial communications to the terminal server. The terminal server's serial port must be properly configured to match the requirements of the serial device to which it is attached. For more
information, refer to "How To... Use Ethernet Encapsulation" in the server help.
l
Network Adapter: Indicate a network adapter to bind for Ethernet devices in this channel. Choose a network adapter to bind to or allow the OS to select the default.
Specific drivers may display additional Ethernet Encapsulation properties. For more information, refer to Channel Properties - Ethernet Encapsulation.
8
Modem Settings
l
Modem: Specify the installed modem to be used for communications.
l
Connect Timeout: Specify the amount of time to wait for connections to be established before failing a read or write. The default is 60 seconds.
l
Modem Properties: Configure the modem hardware. When clicked, it opens vendor-specific modem properties.
l
Auto-Dial: Enables the automatic dialing of entries in the Phonebook. The default is Disable. For
more information, refer to "Modem Auto-Dial" in the server help.
l
Report Comm. Errors: Enable or disable reporting of low-level communications errors. When enabled, low-level errors are posted to the Event Log as they occur. When disabled, these same errors are not posted even though normal request failures are. The default is Enable.
l
Close Idle Connection: Choose to close the modem connection when there are no longer any tags being referenced by a client on the channel. The default is Enable.
l
Idle Time to Close: Specify the amount of time that the server waits once all tags have been removed before closing the modem connection. The default is 15 seconds.
Operation with no Communications
l
Read Processing: Select the action to be taken when an explicit device read is requested. Options include Ignore and Fail. Ignore does nothing; Fail provides the client with an update that indicates failure. The default setting is Ignore.
Channel Properties - Write Optimizations
As with any OPC server, writing data to the device may be the application's most important aspect. The server intends to ensure that the data written from the client application gets to the device on time. Given this goal, the server provides optimization properties that can be used to meet specific needs or improve application responsiveness.
Write Optimizations
www. kepware.com
9
Mitsubishi FX Driver
Optimization Method: controls how write data is passed to the underlying communications driver. The options are: l
Write All Values for All Tags: This option forces the server to attempt to write every value to the controller. In this mode, the server continues to gather write requests and add them to the server's internal write queue. The server processes the write queue and attempts to empty it by writing data to the device as quickly as possible. This mode ensures that everything written from the client applications is sent to the target device. This mode should be selected if the write operation order or the write item's content must uniquely be seen at the target device.
l
Write Only Latest Value for Non-Boolean Tags: Many consecutive writes to the same value can accumulate in the write queue due to the time required to actually send the data to the device. If the server updates a write value that has already been placed in the write queue, far fewer writes are needed to reach the same final output value. In this way, no extra writes accumulate in the server's queue. When the user stops moving the slide switch, the value in the device is at the correct value at virtually the same time. As the mode states, any value that is not a Boolean value is updated in the server's internal write queue and sent to the device at the next possible opportunity. This can greatly improve the application performance.
Note: This option does not attempt to optimize writes to Boolean values. It allows users to optimize the operation of HMI data without causing problems with Boolean operations, such as a momentary push button.
l
Write Only Latest Value for All Tags: This option takes the theory behind the second optimization mode and applies it to all tags. It is especially useful if the application only needs to send the latest value to the device. This mode optimizes all writes by updating the tags currently in the write queue before they are sent. This is the default mode.
Duty Cycle: is used to control the ratio of write to read operations. The ratio is always based on one read for every one to ten writes. The duty cycle is set to ten by default, meaning that ten writes occur for each read operation. Although the application is performing a large number of continuous writes, it must be ensured that read data is still given time to process. A setting of one results in one read operation for every write operation. If there are no write operations to perform, reads are processed continuously. This allows optimization for applications with continuous writes versus a more balanced back and forth data flow.
Note: It is recommended that the application be characterized for compatibility with the write optimization enhancements before being used in a production environment.
Channel Properties - Advanced
This group is used to specify advanced channel properties. Not all drivers support all properties; so the
Advanced group does not appear for those devices.
Non-Normalized Float Handling: Non-normalized float handling allows users to specify how a driver handles non-normalized IEEE-754 floating point data. A non-normalized value is defined as Infinity, Not-a-
Number (NaN), or as a Denormalized Number. The default is Replace with Zero. Drivers that have native float handling may default to Unmodified. Descriptions of the options are as follows: www. kepware.com
Mitsubishi FX Driver l l
Replace with Zero: This option allows a driver to replace non-normalized IEEE-754 floating point values with zero before being transferred to clients.
Unmodified: This option allows a driver to transfer IEEE-754 denormalized, normalized, nonnumber, and infinity values to clients without any conversion or changes.
Note: This property is disabled if the driver does not support floating point values or if it only supports the option that is displayed. According to the channel's float normalization setting, only real-time driver tags
(such as values and arrays) are subject to float normalization. For example, EFM data is not affected by this setting.lin
For more information on the floating point values, refer to "How To ... Work with Non-Normalized Floating
Point Values" in the server help.
Inter-Device Delay: Specify the amount of time the communications channel waits to send new requests to the next device after data is received from the current device on the same channel. Zero (0) disables the delay.
Note: This property is not available for all drivers, models, and dependent settings.
Device Properties
Device properties are organized into the following groups. Click on a link below for details about the properties in that group.
Identification
Operating Mode
Scan Mode
Communication Timeouts
Auto-Demotion
Redundancy
Device Properties - General
A device represents a single target on a communications channel. If the driver supports multiple controllers, users must enter a device ID for each controller.
10
Identification
www. kepware.com
11
Mitsubishi FX Driver
Name: This property specifies the name of the device. It is a logical user-defined name that can be up to
256 characters long, and may be used on multiple channels.
Note: Although descriptive names are generally a good idea, some OPC client applications may have a limited display window when browsing the OPC server's tag space. The device name and channel name become part of the browse tree information as well. Within an OPC client, the combination of channel name and device name would appear as "ChannelName.DeviceName".
For more information, refer to "How To... Properly Name a Channel, Device, Tag, and Tag Group" in server help.
Description: User-defined information about this device.
Many of these properties, including Description, have an associated system tag.
Channel Assignment: User-defined name of the channel to which this device currently belongs.
Driver: Selected protocol driver for this device.
Model: This property specifies the specific type of device that is associated with this ID. The contents of the drop-down menu depends on the type of communications driver being used. Models that are not supported by a driver are disabled. If the communications driver supports multiple device models, the model selection can only be changed when there are no client applications connected to the device.
Note: If the communication driver supports multiple models, users should try to match the model selection to the physical device. If the device is not represented in the drop-down menu, select a model that conforms closest to the target device. Some drivers support a model selection called "Open," which allows users to communicate without knowing the specific details of the target device. For more information, refer to the driver help documentation.
ID: This property specifies the device's driver-specific station or node. The type of ID entered depends on the communications driver being used. For many communication drivers, the ID is a numeric value. Drivers that support a Numeric ID provide users with the option to enter a numeric value whose format can be changed to suit the needs of the application or the characteristics of the selected communications driver.
The ID format can be Decimal, Octal, and Hexadecimal.
Note: If the driver is Ethernet-based or supports an unconventional station or node name, the device's
TCP/IP address may be used as the device ID. TCP/IP addresses consist of four values that are separated by periods, with each value in the range of 0 to 255. Some device IDs are string based. There may be additional properties to configure within the ID field, depending on the driver. For more information, refer to the driver's help documentation.
Operating Mode
Data Collection: This property controls the device's active state. Although device communications are enabled by default, this property can be used to disable a physical device. Communications are not attempted when a device is disabled. From a client standpoint, the data is marked as invalid and write operations are not accepted. This property can be changed at any time through this property or the device system tags.
Simulated: This option places the device into Simulation Mode. In this mode, the driver does not attempt to communicate with the physical device, but the server continues to return valid OPC data. Simulated stops physical communications with the device, but allows OPC data to be returned to the OPC client as valid data.
While in Simulation Mode, the server treats all device data as reflective: whatever is written to the simulated www. kepware.com
Mitsubishi FX Driver device is read back and each OPC item is treated individually. The item's memory map is based on the group
Update Rate. The data is not saved if the server removes the item (such as when the server is reinitialized).
The default is No.
Notes:
1. This System tag (_Simulated) is read only and cannot be written to for runtime protection. The System tag allows this property to be monitored from the client.
2. In Simulation mode, the item's memory map is based on client update rate(s) (Group Update Rate for
OPC clients or Scan Rate for native and DDE interfaces). This means that two clients that reference the same item with different update rates return different data.
Simulation Mode is for test and simulation purposes only. It should never be used in a production environment.
Device Properties - Scan Mode
The Scan Mode specifies the subscribed-client requested scan rate for tags that require device communications. Synchronous and asynchronous device reads and writes are processed as soon as possible; unaffected by the Scan Mode properties.
12
Scan Mode: specifies how tags in the device are scanned for updates sent to subscribed clients.
Descriptions of the options are: l l
Respect Client-Specified Scan Rate: This mode uses the scan rate requested by the client.
Request Data No Faster than Scan Rate: This mode specifies the maximum scan rate to be used.
The valid range is 10 to 99999990 milliseconds. The default is 1000 milliseconds.
Note: When the server has an active client and items for the device and the scan rate value is increased, the changes take effect immediately. When the scan rate value is decreased, the changes do not take effect until all client applications have been disconnected.
l
Request All Data at Scan Rate: This mode forces tags to be scanned at the specified rate for subscribed clients. The valid range is 10 to 99999990 milliseconds. The default is 1000 milliseconds.
l l
Do Not Scan, Demand Poll Only: This mode does not periodically poll tags that belong to the device nor perform a read to get an item's initial value once it becomes active. It is the client's responsibility to poll for updates, either by writing to the _DemandPoll tag or by issuing explicit device reads for individual items. For more information, refer to "Device Demand Poll" in server help.
Respect Tag-Specified Scan Rate: This mode forces static tags to be scanned at the rate specified in their static configuration tag properties. Dynamic tags are scanned at the client-specified scan rate.
Initial Updates from Cache: When enabled, this option allows the server to provide the first updates for newly activated tag references from stored (cached) data. Cache updates can only be provided when the new item reference shares the same address, scan rate, data type, client access, and scaling properties. A device read is used for the initial update for the first client reference only. The default is disabled; any time a client activates a tag reference the server attempts to read the initial value from the device.
www. kepware.com
13
Mitsubishi FX Driver
Device Properties - Timing
The device Communications Timeouts properties allow the driver's response to error conditions to be tailored to fit the application's needs. In many cases, the environment requires changes to these properties for optimum performance. Factors such as electrically generated noise, modem delays, and poor physical connections can influence how many errors or timeouts a communications driver encounters.
Communications Timeouts properties are specific to each configured device.
Communications Timeouts
Connect Timeout: This property (which is used primarily by Ethernet based drivers) controls the amount of time required to establish a socket connection to a remote device. The device's connection time often takes longer than normal communications requests to that same device. The valid range is 1 to 30 seconds. The default is typically 3 seconds, but can vary depending on the driver's specific nature. If this setting is not supported by the driver, it is disabled.
Note: Due to the nature of UDP connections, the connection timeout setting is not applicable when communicating via UDP.
Request Timeout: This property specifies an interval used by all drivers to determine how long the driver waits for a response from the target device to complete. The valid range is 50 to 9,999,999 milliseconds
(167.6667 minutes). The default is usually 1000 milliseconds, but can vary depending on the driver. The default timeout for most serial drivers is based on a baud rate of 9600 baud or better. When using a driver at lower baud rates, increase the timeout to compensate for the increased time required to acquire data.
Retry Attempts: This property specifies how many times the driver retries a communications request before considering the request to have failed and the device to be in error. The valid range is 1 to 10. The default is typically 3, but can vary depending on the driver's specific nature. The number of retries configured for an application depends largely on the communications environment.
Timing
Inter-Request Delay: This property specifies how long the driver waits before sending the next request to the target device. It overrides the normal polling frequency of tags associated with the device, as well as one-time reads and writes. This delay can be useful when dealing with devices with slow turnaround times and in cases where network load is a concern. Configuring a delay for a device affects communications with all other devices on the channel. It is recommended that users separate any device that requires an interrequest delay to a separate channel if possible. Other communications properties (such as communication serialization) can extend this delay. The valid range is 0 to 300,000 milliseconds; however, some drivers may limit the maximum value due to a function of their particular design. The default is 0, which indicates no delay between requests with the target device.
Note: Not all drivers support Inter-Request Delay. This setting does not appear if it is not supported by the driver.
www. kepware.com
Mitsubishi FX Driver
Device Properties - Auto-Demotion
The Auto-Demotion properties can temporarily place a device off-scan in the event that a device is not responding. By placing a non-responsive device offline for a specific time period, the driver can continue to optimize its communications with other devices on the same channel. After the time period has been reached, the driver re-attempts to communicate with the non-responsive device. If the device is responsive, the device is placed on-scan; otherwise, it restarts its off-scan time period.
14
Demote on Failure: When enabled, the device is automatically taken off-scan until it is responding again.
Tip: Determine when a device is off-scan by monitoring its demoted state using the _AutoDemoted system tag.
Timeouts to Demote: Specify how many successive cycles of request timeouts and retries occur before the device is placed off-scan. The valid range is 1 to 30 successive failures. The default is 3.
Demotion Period: Indicate how long the device should be placed off-scan when the timeouts value is reached. During this period, no read requests are sent to the device and all data associated with the read requests are set to bad quality. When this period expires, the driver places the device on-scan and allows for another attempt at communications. The valid range is 100 to 3600000 milliseconds. The default is 10000 milliseconds.
Discard Requests when Demoted: Select whether or not write requests should be attempted during the off-scan period. Disable to always send write requests regardless of the demotion period. Enable to discard writes; the server automatically fails any write request received from a client and does not post a message to the Event Log.
Device Properties - Redundancy
Redundancy is available with the Media-Level Redundancy Plug-in.
Consult the website, a sales representative, or the user manual for more information.
Modem Setup
This driver supports modem functionality. For more information, please refer to Modem Support in the server help.
www. kepware.com
15
Mitsubishi FX Driver www. kepware.com
Mitsubishi FX Driver
Data Types Description
The Mitsubishi FX Driver supports the following data types.
Data
Type
Description
Boolean Single bit
Word Unsigned 16-bit value
Short
Long bit 0 is the low bit bit 15 is the high bit
Signed 16-bit value bit 0 is the low bit bit 14 is the high bit bit 15 is the sign bit
DWord Unsigned 32-bit value bit 0 is the low bit bit 31 is the high bit
Signed 32-bit value
Float bit 0 is the low bit bit 30 is the high bit bit 31 is the sign bit
32-bit Floating point value
String
The driver interprets two consecutive registers as a single precision value by making the last register the high word and the first register the low word.
Null terminated ASCII string
Support includes HiLo LoHi byte order selection and string lengths up to 64 bytes.
16
www. kepware.com
17
Mitsubishi FX Driver
Address Descriptions
Address specifications vary depending on the model in use. Click on a link from the following list to obtain specific address information for the model of interest.
FX Addressing
FX0 Addressing
FX0N Addressing
FX2N Addressing
FX3U Addressing
FX Addressing
The default data types for dynamically defined tags are shown in bold.
Device
Type
Inputs
Outputs
Auxiliary
Relays
Special Aux.
Relays
States
Timer
Contacts
Counter
Contacts
Range
X000-X377*
Y000-Y377*
M0000-M1535
M8000-M8255
S000-S999
TS000-TS255
CS000-CS255
Timer Reset TR000-TR255
Counter
Reset
CR000-CR255
Timer Value T000-T255
Counter
Value
C000-C199
C200-C255 32-bit
Counter
Value**
Data
Registers**
D000-D999
D000-D998
DSH0000.02-DSH0967.64
Data
Registers
String
Access HiLo
Byte
Ordering
Data
Registers
String
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
DSL0000.02-DSL0967.64
The string length may also be specified using a colon. The
Data Type
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Boolean
Read/Write
Read/Write
Short, Word Read/Write
Short, Word Read/Write
Long, DWord Read/Write
Access
Read Only
Read/Write
Read/Write
Read/Write
Read/Write
Read Only
Read Only
Short, Word,
Long, DWord,
Float
String
Read/Write
Read/Write
String
Read/Write www. kepware.com
Mitsubishi FX Driver
Device
Type
Access LoHi
Byte
Ordering
Special
Data
Registers**
Range
string length can range from 2 to 64 bytes, and must be an even number.***
D8000-D8255
D8000-D8254
Data Type Access
Short, Word,
Long, DWord,
Float
Read/Write
*Octal.
**Users can specify a Long data type by appending a space and an "L" to the address. For example, "D000" would be entered as "D000 L". This does not apply to arrays or bit accessed registers.
***For example, a string with HiLo byte ordering at D10 for a length of 12 bytes would be DSH10.12.
FX0 Addressing
The default data types for dynamically defined tags are shown in bold.
Device
Type
Range
Inputs
Outputs
X000-X017*
Y000-Y15*
Auxiliary
Relays
Special Aux.
Relays
States
M0000-M0511
M8000-M8255
Timer
Contacts
S00-S63
TS00-TS55
Counter
Contacts
CS00-CS15
CS235-CS254
Timer Reset TR00-TR55
Counter
Reset
CR00-CR15
CR235-CR254
Timer Value T00-T55
Data
Type
Access
Boolean Read Only
Boolean Read/Write
Boolean Read/Write
Boolean Read/Write
Boolean Read/Write
Boolean Read Only
Boolean Read Only
Boolean Read/Write
Boolean Read/Write
Counter
Value
32-bit
Counter
Value**
Data
Registers**
C00-C15
C235-C254
D00-D31
D00-D30
Data
Registers
String
Short,
Word
Short,
Word
Long,
DWord
Read/Write
Read/Write
Read/Write
DSH0000.02–DSH30.62
The string length may also be specified using a colon. The string
Short,
Word
Long,
DWord,
Float
String
Read/Write
Read/Write
18
www. kepware.com
19
Mitsubishi FX Driver
Device
Type
Access HiLo
Byte
Ordering
Data
Registers
String
Access LoHi
Byte
Ordering
Special Data
Registers**
Range
length can range from 2 to 62 bytes, and must be an even number.***
DSL0000.02–DSL30.62
The string length may also be specified using a colon. The string length can range from 2 to 62 bytes, and must be an even number.***
D8000-D8069
D8000-D8068
Data
Type
Access
String
Read/Write
Short,
Word
Long,
DWord,
Float
Read/Write
*Octal.
**Users can specify a Long data type by appending a space and an "L" to the address. For example, "D00" would be entered as "D00 L". This does not apply to arrays or bit accessed registers.
***For example, a string with HiLo byte ordering at D10 for a length of 12 bytes would be DSH10.12.
FX0N Addressing
The default data types for dynamically defined tags are shown in bold.
Device
Type
Range
Inputs
Outputs
X000-X177*
Y000-Y177*
Auxiliary
Relays
Special Aux.
Relays
States
M0000-M0511
M8000-M8255
Timer
Contacts
Counter
Contacts
S000-S127
TS00-TS63
CS00-CS31
CS235-CS254
Timer Reset TR00-TR63
Counter
Reset
CR00-CR31
CR235-CR254
Timer Value T00-T63
Data
Type
Access
Boolean Read Only
Boolean Read/Write
Boolean Read/Write
Boolean Read/Write
Boolean Read/Write
Boolean Read Only
Boolean Read Only
Boolean Read/Write
Boolean Read/Write
Counter
Value
32-bit
Counter
Value**
C00-C31
C235-C254
Short,
Word
Short,
Word
Long,
DWord
Read/Write
Read/Write
Read/Write www. kepware.com
Mitsubishi FX Driver
Device
Type
Data
Registers**
Range
D000-D255
D000-D254
Data
Type
Short,
Word
Long,
DWord,
Float
String
Access
Read/Write
Read/Write Data
Registers
String
Access HiLo
Byte
Ordering
Data
Registers
String
Access LoHi
Byte
Ordering
DSH0000.02-DSH223.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
DSL0000.02-DSL223.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
Special Data
Registers**
D8000-D8255
D8000-D8254
String
Read/Write
Short,
Word
Long,
DWord,
Float
Read/Write
*Octal.
**Users can specify a Long data type by appending a space and an "L" to the address. For example, "D000" would be entered as "D000 L". This does not apply to arrays or bit accessed registers.
***For example, a string with HiLo byte ordering at D10 for a length of 12 bytes would be DSH10.12.
FX2N Addressing
The default data types for dynamically defined tags are shown in bold.
Device
Type
Range
Inputs
Outputs
X000-X377*
Y000-Y377*
Auxiliary
Relays
Special Aux.
Relays
States
M0000-M3071
M8000-M8255
Timer
Contacts
Counter
Contacts
S000-S999
TS000-TS255
CS000-CS255
Timer Reset TR000-TR255
Data Type Access
Boolean
Boolean
Boolean
Read Only
Read/Write
Read/Write
Boolean
Boolean
Boolean
Boolean
Boolean
Read/Write
Read/Write
Read Only
Read Only
Read/Write
20
www. kepware.com
21
Mitsubishi FX Driver
Device
Type
Range
Counter
Reset
32-bit
Counter
Value**
Data
Registers**
CR000-CR255
Timer Value T000-T255
Counter
Value
C000-C199
C200-C255
D000-D7999
D000-D7998
Data
Registers
String
Access HiLo
Byte
Ordering
Data
Registers
String
Access
LoHi Byte
Ordering
Special
Data
Registers**
DSH0000.02-DSH7967.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
DSL0000.02-DSL7967.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
D8000-D8255
D8000-D8254
Data Type Access
Boolean
Read/Write
Short, Word Read/Write
Short, Word Read/Write
Long, DWord Read/Write
Short, Word,
Long, DWord,
Float
String
Read/Write
Read/Write
String
Read/Write
Short, Word,
Long, DWord,
Float
Read/Write
*Octal.
**Users can specify a Long data type by appending a space and an "L" to the address. For example, "D000" would be entered as "D000 L". This does not apply to arrays or bit accessed registers.
***For example, a string with HiLo byte ordering at D10 for a length of 12 bytes would be DSH10.12.
FX3U Addressing
The default data types for dynamically defined tags are shown in bold.
Note: The FX3U model is not supported in Windows CE. It also does not support Ethernet Encapsulation.
Device
Type
Inputs
Outputs
Auxiliary
Relays
Special Aux.
Relays
States
Range
X000-X377*
Y000-Y377*
M0000-M7679
M8000-M8511
S000-S4095
Data Type Access
Boolean
Boolean
Boolean
Read Only
Read/Write
Read/Write
Boolean
Boolean
Read/Write
Read/Write www. kepware.com
Mitsubishi FX Driver
Device
Type
Range
Timer
Contacts
Counter
Contacts
TS000-TS511
CS000-CS255
Timer Reset TR000-TR511
Counter
Reset
CR000-CR255
Timer Value T000-T511
Counter
Value
C000-C199
C200-C255 32-bit
Counter
Value**
Data
Registers**
D000-D7999
D000-D7998
Data
Registers
String
Access HiLo
Byte
Ordering
Data
Registers
String
Access LoHi
Byte
Ordering
File
Registers**
DSH0000.02-DSH7967.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
DSL0000.02-DSL7967.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
R000-R32767
R000-R32766
File
Registers
String
Access
HiLo Byte
Ordering
File
Registers
String
Access LoHi
Byte
Ordering
Special
Data
Registers**
RSH0000.02-RSH32735.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
RSL0000.02-RSL32735.64
The string length may also be specified using a colon. The string length can range from 2 to 64 bytes, and must be an even number.***
D8000-D8511
D8000-D8510
Data Type Access
Boolean
Read Only
Boolean
Boolean
Boolean
Read Only
Read/Write
Read/Write
Short, Word Read/Write
Short, Word Read/Write
Long, DWord Read/Write
Short, Word,
Long, DWord,
Float
String
Read/Write
Read/Write
String
String
Read/Write
Short, Word,
Long, DWord,
Float
String
Read/Write
Read/Write
Read/Write
Short, Word,
Long, DWord,
Float
Read/Write
22
www. kepware.com
23
Mitsubishi FX Driver
*Octal.
**Users can specify a Long data type by appending a space and an "L" to the address. For example, "D000" would be entered as "D000 L". This does not apply to arrays or bit accessed registers.
***For example, a string with HiLo byte ordering at D10 for a length of 12 bytes would be DSH10.12
www. kepware.com
Mitsubishi FX Driver
Event Log Messages
The following information concerns messages posted to the Event Log pane in the main user interface.
Consult the server help on filtering and sorting the Event Log detail view. Server help contains many common messages, so should also be searched. Generally, the type of message (informational, warning) and troubleshooting information is provided whenever possible.
24
Received block length does not match expected length. | Received block length = <number>, Expected block length = <number>.
Error Type:
Warning
Possible Cause:
The data type maximum length or the length dictated in the address definition set a range that the results do not fit.
Possible Solution:
Verify the data type is correct and check the address definition for a length definition and correct or update.
Error Mask Definitions
B = Hardware break detected
F = Framing error
E = I/O error
O = Character buffer overrun
R = RX buffer overrun
P = Received byte parity error
T = TX buffer full www. kepware.com
25
Mitsubishi FX Driver
Appendix: Ethernet Encapsulation Examples
Note: The following is provided for convenience only. Refer to the manufacturer's documentation for current and official instructions.
Click on a link below for a specific Ethernet encapsulation example.
Using COM-ET10-T Ethernet Module
Using the FX2NC-ENET-ADP Ethernet Module
Using the FX3U-ENET Ethernet Module
Writing Network Parameters to the PLC
Note: Ethernet Encapsulation is not supported by the FX3U device model.
Using COM-ET10-T Ethernet Module
Mitsubishi Electric has an Ethernet module that allows peer-to-peer Ethernet connection to FX1S, FX1N,
FX2NC or FX2NC model controllers. The COM-ET10-T module connects to the controller via the FX1N-CNV-
BD or the FX2N-CNV-BD communications adapter. For equipment information, refer to the FX hardware manual.
Example Parameters
The Module ID is Fixed at ET10
E = 45
T = 54
1 = 31
0 = 30
IP Address: 192.168.108.10
192 = C0
168 = A8
108 = 6C
10 = 0A
Subnet Mask: 255.255.255.0
255 = FF
255 = FF
255 = FF
0 = 00
Gateway IP Address: 192.168.108.01
192 = C0
168 = A8
108 = 6C
1 = 01
UPD Port: 1024
TCP Port1: 1025
TCP Port2: 1026
The module currently supports only connecting to TCP Port 1025.
Mitsubishi FX 2N() Series Ladder
Ladder Logic for initializing the module. The configuration parameters are stored in data registers. Any thousand range with the D register area beginning with D0, D1000, D2000 and etc can be used.
|---| M8002 |--------------[ MOV H81 D8120 ] 'Set communication register
| |--------[ DMOV H45543130 D1000 ] 'Module ID ET10 (Fixed)
| |-------[ DMOV H0C0A86C0A D1002 ] 'Module IP Address
| |-------[ DMOV H0FFFFFF00 D1004 ] 'Subnet Mask
| |-------[ DMOV H0C0A86C01 D1006 ] 'Gateway IP Address www. kepware.com
Mitsubishi FX Driver
| |-------------[ MOV K1024 D1008 ] 'UDP Port Number
| |-------------[ MOV K1025 D1009 ] 'TCP Port Number 1
| |-------------[ MOV K1026 D1010 ] 'TCP Port Number 2
| |----------------[ MOV K0 D1011 ] 'System Area Default Value 0
| |----------------[ MOV K0 D1012 ] 'System Area Default Value 0
| |----------------[ MOV K0 D1013 ] 'System Area Default Value 0
| |----------------[ 'System Area Default Value 0
| |----------------[ MOV K0 D1015 ] 'System Area Default Value 0
Note: This information has been taken from the Mitsubishi Electric Ethernet Communications Module COM
ET10-T manual.
Using the FX2NC-ENET-ADP Ethernet Module
Mitsubishi has an Ethernet module that allows peer to peer Ethernet connection to FX1S, FX1N, FX2NC or
FX2NC model controllers. The FX2NC-ENET_ADP module connects to the controller via the FX1N-CNV-BD or the FX2N-CNV-BD communications adapter. For equipment information, refer to the FX hardware manual.
Example Parameters
The Module ID is Fixed at ENET
E = 45
N = 4E
E = 45
T = 54
IP Address: 192.168.108.10
192 = C0
168 = A8
108 = 6C
10 = 0A
Subnet Mask: 255.255.255.0
255 = FF
255 = FF
255 = FF
0 = 00
Gateway IP Address: 192.168.108.01
192 = C0
168 = A8
108 = 6C
1 = 01
TCP Port: 1024
Mitsubishi FX1s Series Ladder
Ladder Logic for initializing the module on a FX1s. Set the Ethernet parameters in 9 data registers starting from D128 to D136.
|---| M8002 |-----------[ DMOV H454E4554 D128 ] 'Module ID ENET (Fixed)
| |-------[ DMOV H0C0A86C0A D130 ] 'Module IP Address
| |-------[ DMOV H0FFFFFF00 D132 ] 'Subnet Mask
| |-------[ DMOV H0C0A86C01 D134 ] 'Gateway IP Address
| |-------------[ MOV K1024 D136 ] 'TCP Port Number
Mitsubishi FX1N/2N/2NC Series Ladder
Ladder Logic for initializing the module on a FX1s. Set the Ethernet parameters in 9 data registers starting from D1000 to D1008. If these registers are used for other purposes, set to 9 data registers starting at
D2000, D3000, D4000, D5000, D6000 or D7000.
|---| M8002 |-----------[ DMOV H454E4554 D1000 ] 'Module ID ENET (Fixed)
| |-------[ DMOV H0C0A86C0A D1002 ] 'Module IP Address
| |-------[ DMOV H0FFFFFF00 D1004 ] 'Subnet Mask
| |-------[ DMOV H0C0A86C01 D1006 ] 'Gateway IP Address
| |-------------[ MOV K1024 D1008 ] 'TCP Port Number
26
www. kepware.com
27
Mitsubishi FX Driver
Note: This information has been taken from the Mitsubishi FX2NC-ENET-ADP Ethernet Adapter Users manual.
Using the FX3U-ENET Ethernet Module
To connect to the FX3U PLC via the FX3U-ENET Ethernet module, use Ethernet Encapsulation. In order to do so, the FX3U-ENET module must be configured using the Mitsubishi GX Developer-FX software. For more information, follow the instructions below.
1. To start, create a new GX Developer project for a FX3U model.
2. Then, select Tools | FX special functions utility | FX Configurator-EN.
www. kepware.com
Mitsubishi FX Driver
3. The FX Configurator-EN dialog should appear as shown below.
28
4. Next, fill in the minimum required configuration information for the FX3U-ENET block. Select a module from the first drop-down list, and then click Operational Settings. The settings should be similar to those shown in the image below.
www. kepware.com
29
Mitsubishi FX Driver
5. Click End to continue.
6. In the FX Configurator-EN dialog window, click Open Settings.
Writing Network Parameters to the PLC
After the network parameters have been specified, they must be written to the PLC. To do so, click Write from the FX-Configurator-EN window.
www. kepware.com
Mitsubishi FX Driver
There must be a serial connection to the FX3U PLC because the configuration settings are written to the PLC via this serial link. Make sure that the communication parameters are correct by using the Transfer setup button above or by clicking Online | Transfer setup from the main menu.
After the parameters have been written, cycle the power on the PLC for the network parameter changes to take effect. Now, the FX3U PLC can be communicated with using Ethernet encapsulation via the FX3U-ENET
Ethernet module. Use the following parameters: l
IP Address: 10.10.110.107 (or the IP address used above) l l
Port Number: 5551
Protocol: TCP/IP
30
www. kepware.com
31
Index
A
Appendix
B
C
Channel Properties - General 5
Channel Properties - Write Optimizations 8
D
www. kepware.com
Mitsubishi FX Driver
Mitsubishi FX Driver
Device Properties - Auto-Demotion 14
Device Properties - General 10
Discard Requests when Demoted 14
Do Not Scan, Demand Poll Only 12
E
F
H
www. kepware.com
32
33
I
L
M
Mitsubishi FX 2N() Series Ladder 25
Mitsubishi FX1N/2N/2NC Series Ladder 26
Mitsubishi FX1s Series Ladder 26
N
Non-Normalized Float Handling 9
O
www. kepware.com
Mitsubishi FX Driver
Mitsubishi FX Driver
P
R
Received block length does not match expected length. | Received block length = <number>, Expected
Request All Data at Scan Rate 12
Request Data No Faster than Scan Rate 12
Respect Client-Specified Scan Rate 12
Respect Tag-Specified Scan Rate 12
S
Supported Communication Parameters 4
T
www. kepware.com
34
35
W
Write All Values for All Tags 9
Write Only Latest Value for All Tags 9
Write Only Latest Value for Non-Boolean Tags 9
Mitsubishi FX Driver www. kepware.com
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 1 Mitsubishi FX Driver
- 2 Table of Contents
- 3 Mitsubishi FX Driver
- 3 Overview
- 4 Setup
- 5 Channel Properties
- 5 Channel Properties - General
- 6 Channel Properties - Serial Communications
- 8 Channel Properties - Write Optimizations
- 9 Channel Properties - Advanced
- 10 Device Properties
- 10 Device Properties - General
- 12 Device Properties - Scan Mode
- 13 Device Properties - Timing
- 14 Device Properties - Auto-Demotion
- 14 Device Properties - Redundancy
- 14 Modem Setup
- 16 Data Types Description
- 17 Address Descriptions
- 17 FX Addressing
- 18 FX0 Addressing
- 19 FX0N Addressing
- 20 FX2N Addressing
- 21 FX3U Addressing
- 24 Event Log Messages
- 24 Received block length does not match expected length. | Received block length...
- 24 Error Mask Definitions
- 25 Appendix: Ethernet Encapsulation Examples
- 31 Index