- No category
advertisement
SOYAL
ACCESS CONTROL SYSTEM
®
AR-723H
V110713
Content & Feature
1 Product 2 User Guide
Connector Table
Stand-Alone
6 5
LED
4 3 2 1
P1
3 Terminal Cables
P3
4 Optional
AR-WG-KEYBOARD AR-821-RB or
AR-721-RB
5 Feature
Standalone and Networking model for selection
1 Bi-color LED & 1 Buzzer
Built-in Watch Dog to prevent system from hanging
The Master Card function for adding/ deleting cards
Can set parameters by external keyboard
BZ
P3
Networking
LED
BZ
P3
8 7 6 5 4 3 2
P2
1
(NO RS-485)
Application Wire Color Description
Power
R.T.E
Power
1 Black DC 0V (GND)
2 Brown Negative Trigger Input
3 Red DC 12V
Door Contact 4 Orange Negative Trigger Input
Alarm Relay 5 Yellow Open collector output
Lock Relay 6 Green Open collector output/
Application Wire Color Description
Power
1 Black DC 0V (GND)
2 Red DC 12V
(RS-485)
Alarm Relay 3 Gray Open collector output
R.T.E
4 Purple Negative Trigger Input
Door Contact 5 Orange Negative Trigger Input
Lock Relay
RS-485
6 White Open collector output/
7 Blue RS-485 A+
8 Green RS-485 B-
P3 WG Input Port
Application Wire Color Description
1
2
3
WG
Power
4 Blue WG DATA 1
5 Green WG DATA 0
6 Red DC 12V
7 Black DC 0V (GND)
P4 TTL Cable (Optional)
Application Wire Color Description
1 Yellow TX
TTL 2 White TE
3 Orange RX
Power
4
5
6 Red DC 12V
7 Black DC 0V (GND)
When update firmware or set function for standalone model, please order .
P3
P4
P4
Diagram
Connect to Electric Strike
POWER
12VDC
N.O.
EXIT
AR-723H
Diode
Request To Exit
1
3
5
2
4
6
GND
12V
ALM
PB
SEN
Door
A+
B-
5
6
7
8
1
2
3
4
Electric Strike
N.C.
N.O.
COM
CTL
12V
AR-821RB
P1 or P2 POWER
12VDC
※ are not in order, please refer to [Connector Table]
Connect to Door Contact and Alarm
POWER
12VDC Alarm
1
3
GND 1
2
N.C.
N.O.
5
12V
ALM 3
COM
CTL
12V
2
4
6
PB
SEN
4
P1
Door
5
6
AR-821RB
A+
Bor
7
8
P2 N.C.
P1
Door Contact
AR-723H
※ are not in order, please refer to [Connector Table]
Strengthen security with AR-721RB
POWER
12VDC
N.O.
EXIT
AR-723H
Request To Exit
2
4
6
1
3
5
P1
GND
12V
ALM
PB
SEN
Door
A+
Bor
1
2
3
4
5
6
7
8
P2
N.C.
Electric Bolt
N.C.
N.O.
COM
CTL
12V
GND
PB
DECODER
AR-721RB
POWER
12VDC
※ are not in order, please refer to [Connector Table]
Connect to Reader or Keyboard
AR-723H
LED
BZ P3
GND
12V
WG0
WG1
P3
3
2
1
7
6
5
4
Black
Red
Green
Blue
WG Reader or
WG Keyboard
GND
12V
WG 0
WG 1
Access Controller
V110713
About Master Card
MASTER CARD Setting for Stand-Alone
P3
GND
12V
RX
TE
TX
4
3
2
1
7
6
5
Black
Red
Orange
White
Yellow
Use the MASTER CARD software
Converter
TTL USB
1
2
323DMaster
Input the MASTER CARD number, and press [Write].
Cut off and then transmit the power, the master card number will be activated.
Present the card, and the reader will flash green light 3 times and sound 3 beeps. Then the card becomes MASTER CARD and accesses programming mode.If MASTER CARD is presented again, it will exit programming mode.
Adding Tag Deleting All Tags
1.
Present Master Card 1.
Present Master Card
2.
After 3 short beeps
[Access programming mode]
2.
After 3 short beeps
[Access programming mode]
3.
1 long warning beep after 2sec.
3.
Present one new card at a time
4.
5 short beeps after 5sec: cards cleared
4.
Present Master Card
[Exit programming mode]
P.S. Once MASTER CARD is presented after one
warning beep, all card data will be cleared.
Operation process
A. Enter/ Exit Program Mode
Enter the program mode
Input 123456 or PPPPPP
[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → program mode accessed
Exit the program mode
Input
Master Code modification
Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]
[e.g.] Set the Master code to be 876112, input 123456 → 09 876112876112
B. Set up the password
[Only for connect to external K-series reader]
M4/M8: Individual pass code
Card or PIN: Access programming mode → 12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]
Card and PIN: Access programming mode → 13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]
M6: Public pass word
Card or PIN: Access programming mode → 15 PPPP [Input 4-digit pass code, default value: 4321]
Card and PIN: Access programming mode → 17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]
C. Anti-pass-back(M4/M8)
Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need access and exit monitor.
Enable controller
Access programming mode → 20 DDD [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]
[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128
Access programming mode → 20 128 (Please refer to function default value for details.)
Enable card
Access programming mode → 26 SSSSS EEEEE N
[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]
[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0
[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he represent into the door will become
invalid , then he needs to set the reset. Access programming mode → 26 00154 00154 2 → Reset
D. Lift control
Connect with AR-401RO16B to control floors which the user will be able to access.
Enable
Access programming mode → 24 002 [002= enable lift control]
SOYAL
ACCESS CONTROL SYSTEM
®
AR-723H
V110713
Single floor
Access programming mode → 27 UUUUU FF
UUUU=User Address FF=Floor number (01~32 floor)
[e.g.] User address NO. 45, allow to access the 24th floor: 27 00045 24
Multi floors
Access programming mode → 21 UUUUU S FFFFFFFF
Set
0
1
2
3
[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)
[e.g.] User address NO. 168, only to the 6th and the 20th floor:
Access programming mode → 21 00168 0 00100000 → 21 00168 2 00001000
Floor/ Stop
F
8
16
24
32
F
7
15
23
31
F
6
14
22
30
F
5
13
21
29
F
4
12
20
28
F
3
11
19
27
F
2
10
18
26
F
1
9
17
25
E. Setting Up the Arming
[Only for connect to external K-series reader]
Alarm conditions: Application:
1. Arming is enabled
2.Alarm system connected
1. Door open too long: Door is open longer than door relay time plus door close time.
2. Force open (Opened without a valid user card): Access by force or illegal procedure.
3. Door position abnormal: Arming is enabled and the power is suddenly off then on.
Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234) :
Standby Mode
After door open Do not open the door
The normal procedure to open door → Input 4 digit arming code →
Enter Program Mode
→ Input 4 digit arming code → Present valid card
Enable: Access programming mode →
※ [The normal procedure to open door] can refer to [Access Mode].
Disable: Access programming mode →
Function Default Value
20 DDD
※ Default Value
Function
Attendance
Auto Re-lock
Auto Open
※ 0: Yes
Selection
1: No
Value Application
001 Networking
※ 0: Disable 1: Enable 002 Networking/Stand-Alone
※ 0: Disable 1: Enable 004 Networking/Stand-Alone
Door open button input 0: Disable ※1: Enable 016 Networking/Stand-Alone
Master Controller of Network ※0: Slave 1: Mater 032 Networking
Access/Exit
Anti-pass-back
※
※
0: Exit 1: Access 064 Networking
0: Disable 1: Enable 128 Networking
24 DDD
※ Default Value
Function Selection Value Application
Auto-open door without cards at auto open zone ※0: Disable 1: Enable 001 Networking/Stand-Alone
Alarm Output/ Lift Control
Stop Alarm by door close or by push button
※ 0: Alarm Output 1: Lift Control 002 Networking/Stand-Alone
0: None ※ 1: Yes 064 Networking/Stand-Alone
28 DDD
※ Default Value
Function
Dual Door Control ※
Selection Value Application
0: Disable 1: Enable 064 Networking/Stand-Alone
Force Open Alarm Output ※0: Disable 1: Enable 128 Networking/Stand-Alone
Selection= 0(none value)/ 1(1 x each value)
[e.g.] DDD value of Enable “Auto Open” + ”Exit by Push Button +
”Anti-pass-back”
=(0x1)+(0x2)+(1X4)+(1x16)+(0x32)+(0x64)+(1x128)=148;
As a result of that, the command will be 20 148 .
Mode4 / Mode6 / Mode8
User
Capacity
Access Mode
Auto-show
Duty time
Event log
Capacity
120
Holidays
Anti force
Time
Zone
Lift
Control
Anti-passback
M4
M6 Stand-Alone
M8
Networking/
Stand-Alone
Networking/
Stand-Alone
1,024
65,535
1,024
1.Card only
2.Card and PIN (4-digit PIN) +
3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) +
1.Card only
2.Card and PIN (4-digit public PIN= Arming PWD) +
3.Card or PIN (4-digit public PIN= Duress code)
1.Card only
2.Card and PIN (4-digit individual PIN) +
3.Card or PIN (4-digit individual PIN)
Yes
No
Yes
1,200
No
1,200
Yes
No
Yes
Yes
No
Yes
No
No
No
32
No
32
Yes
No
Yes
※ Mode 6, the number of users up to 65535, since it reads CARD CODE(5 digits) only, unlike that Mode4/Mode8 read SITE CODE and CARD CODE(10 digits).
If Access Mode setting to use the PIN, it need to external the K-series Readers.
Factory Reset by its commands
When the device is stand-alone (not networking)
Access programming mode → 20 016 → 24 064 → 26 00000 01023 1 → 28 000 → 29 29
※ Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.
Access Controller
V110713
Command List
Function
Entering programming mode
Command
PPPPPP
Exiting programming mode
Exiting programming mode and enabling arming status
Node ID setting (Connecting to 716E 00 NNN
Node ID setting (Connecting to PC directly without via 716E)
00 NNN VVV nnn
Mifare tag / card format (Optional)
Door relay time setting
Alarm relay time setting
Control mode setting
Arming delay time setting
Alarm delay time setting
Master card setting
Auto-open time zone setting
02 TTT
03 TTT
04 N
05 TTT
06 TTT
07 SSSSS EEEEE
Master code setting 09 PPPPPPRRRRRR
Setting
Suspend tag(M6) 10 SSSSS EEEEE
Delete tag(M4)
Set a sequence of cards as "read and access"
Active the suspended cards
11 SSSSS EEEEE
11 SSSSS EEEEE
Set the cards as Card mode OR PIN mode by user address
12 UUUUU PPPP
Set the cards as Card AND PIN mode by user address
13 UUUUU PPPP
M4: Duress code setting
M6: Public PIN setting (Card or PIN)
15 PPPP
Card number modification 16 UUUUU SSSSSCCCCC
M4: Arming pass code setting
M6: Public PIN setting (Card and PIN)
Door open waiting time
Set the card by induction
Reader additional setting
Lift control setting: multi-doors
Add/Delete tag by induction (M6 only)
AR-401ROsite number dip switch
Controller parameter setting
Controller time clock setting
17 PPPP
18 TTT
19 UUUUU QQQQQ
20 DDD
21 UUUUU S FFFFFFFF
22 N
23 NNN TTT
24 DDD
25 YYMMDDHHmmss
Anti-pass-back (Enable user) 26 SSSSS EEEEE N
Single floor setting
Dual door control/ Active or inactive arming for force open
Delete all tags
Enable the security trigger signal ( with AR-721RB)
27 UUUUU FF
28 DDD
29 29
34 064 (Enable)
34 000 (Disable)
01 N
08 N HHMMhhmm 7123456H
Description
PPPPPP=Master Code, default value= 123456
NNN=Node ID, range: 001~254
NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, nnn=Door number; range:001~254
N: 0=ISO14443A; 1=ISO14443B; 2=ISO15693;
3=I Code1; 4=I Code2
PS.1. Please select the compliance,first.
2. Make sure reader and card using the same compliance.
Mode
M4/M6/M8
M4/M6/M8
M4/M8
M4/M8
M4/M8
M4/M8
TTT=Door relay time 000= Output constantly
001~600=1~600 sec.
601~609=0.1~0.9 sec.
TTT=Alarm relay time 000= Output constantly 001~600=1~600 sec.
N=Mode 4=Mode4; 6=Mode6; 8=Mode8
TTT=Alarm relay time 001~600=1~600 sec.
TTT=Alarm delay time 001~600=1~600 sec.
SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H);
SSSSS=Starting user address; EEEEE=Ending user address
N= 0(1st time zone) / 1(2nd time zone)
HHMM= Starting time; hhmm= ending time
(i.e.: 08301200=08:30 to 12:00)
7123456H= 7 days of week (Sun/Mon/Tue/Wed/Thu/Fri/Sat)+ Holiday
(H= 0: disable; 1: enable); Holidays establish by the software.
PPPPPP=New master code
RRRRRR=Repeat the new master code
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M6/M8
M4/M8
M4/M6/M8
M4/M6/M8
SSSSS=Starting user address, EEEEE=Ending user address
SSSSS=Starting card number; EEEEE=Ending card number
SSSSS=Starting user address; EEEEE=Ending user address
Access mode: Card or PIN; UUUUU=user address;
PPPP=4-digit pass code 0001~9999
Access mode: Card and PIN; UUUUU=user address;
PPPP=4-digit pass code 0001~9999
PPPP=4-digit pass code (default value= 4321)
P.S. Duress code will be unavailable and become a public PIN at access mode “ Card or PIN” of M6
M4/M6/M8
M6
M4/M8
M4/M8
M4/M8
M4/M6/M8
M4/M8
UUUUU= User address; SSSSS=5-digit site code;
CCCCC=5-digit card code
M4/M6/M8
PPPP=4-digit pass code ( default value= 1234; disable Arming PWD=0000)
P.S. Arming PWD code will be unavailable and become a public PIN at access mode “ Card PIN” and of M6
M4/M6/M8
TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec. M4/M8
UUUUU=User address;
QQQQQ=Card quantity( 00001=Continuously inducting)
M4/M6/M8
Please refer to function default value for details.
M4/M6/M8
UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor
(F=0: Disable, 1: Enable)
M4/M8
N=0(Delete tag); N=1(Add tag)
NNN=site number, TTT= relay time: 000~600=1~600 sec.
Please refer to function default value for details.
YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec.
M6
M4/M8
M4/M6/M8
M4/M6/M8
SSSSS=Starting user address; EEEEE=Ending user address;
N=0/Enable; N=1/Disable; N=2/Initial
M4/M8
UUUUU=User Address; FF=Floor (01~32 floor)
Please refer to function default value for details.
M4/M8
M4/M6/M8
M4/M6/M8
To Change the "Door Lock" become the security trigger signal, when controller is connected with AR-721RB.
M4/M6/M8
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement