AR-723H


Add to my manuals
4 Pages

advertisement

AR-723H | Manualzz

SOYAL

ACCESS CONTROL SYSTEM

®

AR-723H

V110713

Content & Feature

1 Product 2 User Guide

Connector Table

Stand-Alone

6 5

LED

4 3 2 1

P1

3 Terminal Cables

P3

4 Optional

AR-WG-KEYBOARD AR-821-RB or

AR-721-RB

5 Feature

Standalone and Networking model for selection

1 Bi-color LED & 1 Buzzer

Built-in Watch Dog to prevent system from hanging

The Master Card function for adding/ deleting cards

Can set parameters by external keyboard

BZ

P3

Networking

LED

BZ

P3

8 7 6 5 4 3 2

P2

1

(NO RS-485)

Application Wire Color Description

Power

R.T.E

Power

1 Black DC 0V (GND)

2 Brown Negative Trigger Input

3 Red DC 12V

Door Contact 4 Orange Negative Trigger Input

Alarm Relay 5 Yellow Open collector output

Lock Relay 6 Green Open collector output/

Application Wire Color Description

Power

1 Black DC 0V (GND)

2 Red DC 12V

(RS-485)

Alarm Relay 3 Gray Open collector output

R.T.E

4 Purple Negative Trigger Input

Door Contact 5 Orange Negative Trigger Input

Lock Relay

RS-485

6 White Open collector output/

7 Blue RS-485 A+

8 Green RS-485 B-

P3 WG Input Port

Application Wire Color Description

1

2

3

WG

Power

4 Blue WG DATA 1

5 Green WG DATA 0

6 Red DC 12V

7 Black DC 0V (GND)

P4 TTL Cable (Optional)

Application Wire Color Description

1 Yellow TX

TTL 2 White TE

3 Orange RX

Power

4

5

6 Red DC 12V

7 Black DC 0V (GND)

When update firmware or set function for standalone model, please order .

P3

P4

P4

Diagram

Connect to Electric Strike

POWER

12VDC

N.O.

EXIT

AR-723H

Diode

Request To Exit

1

3

5

2

4

6

GND

12V

ALM

PB

SEN

Door

A+

B-

5

6

7

8

1

2

3

4

Electric Strike

N.C.

N.O.

COM

CTL

12V

AR-821RB

P1 or P2 POWER

12VDC

※ are not in order, please refer to [Connector Table]

Connect to Door Contact and Alarm

POWER

12VDC Alarm

1

3

GND 1

2

N.C.

N.O.

5

12V

ALM 3

COM

CTL

12V

2

4

6

PB

SEN

4

P1

Door

5

6

AR-821RB

A+

Bor

7

8

P2 N.C.

P1

Door Contact

AR-723H

※ are not in order, please refer to [Connector Table]

Strengthen security with AR-721RB

POWER

12VDC

N.O.

EXIT

AR-723H

Request To Exit

2

4

6

1

3

5

P1

GND

12V

ALM

PB

SEN

Door

A+

Bor

1

2

3

4

5

6

7

8

P2

N.C.

Electric Bolt

N.C.

N.O.

COM

CTL

12V

GND

PB

DECODER

AR-721RB

POWER

12VDC

※ are not in order, please refer to [Connector Table]

Connect to Reader or Keyboard

AR-723H

LED

BZ P3

GND

12V

WG0

WG1

P3

3

2

1

7

6

5

4

Black

Red

Green

Blue

WG Reader or

WG Keyboard

GND

12V

WG 0

WG 1

Access Controller

V110713

About Master Card

MASTER CARD Setting for Stand-Alone

P3

GND

12V

RX

TE

TX

4

3

2

1

7

6

5

Black

Red

Orange

White

Yellow

Use the MASTER CARD software

Converter

TTL USB

1

2

323DMaster

Input the MASTER CARD number, and press [Write].

Cut off and then transmit the power, the master card number will be activated.

Present the card, and the reader will flash green light 3 times and sound 3 beeps. Then the card becomes MASTER CARD and accesses programming mode.If MASTER CARD is presented again, it will exit programming mode.

Adding Tag Deleting All Tags

1.

Present Master Card 1.

Present Master Card

2.

After 3 short beeps

[Access programming mode]

2.

After 3 short beeps

[Access programming mode]

3.

1 long warning beep after 2sec.

3.

Present one new card at a time

4.

5 short beeps after 5sec: cards cleared

4.

Present Master Card

[Exit programming mode]

P.S. Once MASTER CARD is presented after one

warning beep, all card data will be cleared.

Operation process

A. Enter/ Exit Program Mode

Enter the program mode

Input 123456 or PPPPPP

[e.g.] The Default Value= 123456, if already changed the Master Code= 876112, input 876112 → program mode accessed

Exit the program mode

Input

Master Code modification

Access programming mode → 09 PPPPPPRRRRRR [Input the 6-digit new master code twice.]

[e.g.] Set the Master code to be 876112, input 123456 → 09 876112876112

B. Set up the password

[Only for connect to external K-series reader]

M4/M8: Individual pass code

Card or PIN: Access programming mode → 12 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 12 00001 1234 ]

Card and PIN: Access programming mode → 13 UUUUU PPPP [e.g. User address: 00001 and pass code: 1234, input 13 00001 1234 ]

M6: Public pass word

Card or PIN: Access programming mode → 15 PPPP [Input 4-digit pass code, default value: 4321]

Card and PIN: Access programming mode → 17 PPPP [Input 4-digit pass code, default value: 1234; PPPP=0000: change into Card Only]

C. Anti-pass-back(M4/M8)

Usually, anti-pass-back is commonly applied to parking areas in order to prevent from multi-entry with one card at a time, or to situations need access and exit monitor.

Enable controller

Access programming mode → 20 DDD [128= Anti-pass-back(0=Disable; 1=Enable)/ 064=Access/Exit(0=Exit; 1=Access).]

[e.g.] Enable Anti-pass-back, and set to Exit door= (128 x 1) + (064 x 0) = 128

Access programming mode → 20 128 (Please refer to function default value for details.)

Enable card

Access programming mode → 26 SSSSS EEEEE N

[SSSSS= User address start; EEEEE= User address end; N=0(control)/ 1(Not control)/ 2(reset)]

[e.g.] User address from 00152 to 00684 enable the anti-pass-back function: 26 00152 00684 0

[e.g.] No. 154 enable the anti-pass-back, and induction into the door has not been induced to leave. When he represent into the door will become

invalid , then he needs to set the reset. Access programming mode → 26 00154 00154 2 → Reset

D. Lift control

Connect with AR-401RO16B to control floors which the user will be able to access.

Enable

Access programming mode → 24 002 [002= enable lift control]

SOYAL

ACCESS CONTROL SYSTEM

®

AR-723H

V110713

Single floor

Access programming mode → 27 UUUUU FF

UUUU=User Address FF=Floor number (01~32 floor)

[e.g.] User address NO. 45, allow to access the 24th floor: 27 00045 24

Multi floors

Access programming mode → 21 UUUUU S FFFFFFFF

Set

0

1

2

3

[UUUUU=User address S: 4 sets of lift control (Input: 0~3) FFFFFFFF: 8 floors setting (F=0=Disable, F=1=Enable)

[e.g.] User address NO. 168, only to the 6th and the 20th floor:

Access programming mode → 21 00168 0 00100000 → 21 00168 2 00001000

Floor/ Stop

F

8

16

24

32

F

7

15

23

31

F

6

14

22

30

F

5

13

21

29

F

4

12

20

28

F

3

11

19

27

F

2

10

18

26

F

1

9

17

25

E. Setting Up the Arming

[Only for connect to external K-series reader]

Alarm conditions: Application:

1. Arming is enabled

2.Alarm system connected

1. Door open too long: Door is open longer than door relay time plus door close time.

2. Force open (Opened without a valid user card): Access by force or illegal procedure.

3. Door position abnormal: Arming is enabled and the power is suddenly off then on.

Enable/Disable Arming status (for M4/M8; Factory default armingcode is: 1234) :

Standby Mode

After door open Do not open the door

The normal procedure to open door → Input 4 digit arming code

Enter Program Mode

Input 4 digit arming codePresent valid card

Enable: Access programming mode →

※ [The normal procedure to open door] can refer to [Access Mode].

Disable: Access programming mode →

Function Default Value

20 DDD

※ Default Value

Function

Attendance

Auto Re-lock

Auto Open

※ 0: Yes

Selection

1: No

Value Application

001 Networking

※ 0: Disable 1: Enable 002 Networking/Stand-Alone

※ 0: Disable 1: Enable 004 Networking/Stand-Alone

Door open button input 0: Disable ※1: Enable 016 Networking/Stand-Alone

Master Controller of Network ※0: Slave 1: Mater 032 Networking

Access/Exit

Anti-pass-back

0: Exit 1: Access 064 Networking

0: Disable 1: Enable 128 Networking

24 DDD

※ Default Value

Function Selection Value Application

Auto-open door without cards at auto open zone ※0: Disable 1: Enable 001 Networking/Stand-Alone

Alarm Output/ Lift Control

Stop Alarm by door close or by push button

※ 0: Alarm Output 1: Lift Control 002 Networking/Stand-Alone

0: None ※ 1: Yes 064 Networking/Stand-Alone

28 DDD

※ Default Value

Function

Dual Door Control ※

Selection Value Application

0: Disable 1: Enable 064 Networking/Stand-Alone

Force Open Alarm Output ※0: Disable 1: Enable 128 Networking/Stand-Alone

Selection= 0(none value)/ 1(1 x each value)

[e.g.] DDD value of Enable “Auto Open” + ”Exit by Push Button +

”Anti-pass-back”

=(0x1)+(0x2)+(1X4)+(1x16)+(0x32)+(0x64)+(1x128)=148;

As a result of that, the command will be 20 148 .

Mode4 / Mode6 / Mode8

User

Capacity

Access Mode

Auto-show

Duty time

Event log

Capacity

120

Holidays

Anti force

Time

Zone

Lift

Control

Anti-passback

M4

M6 Stand-Alone

M8

Networking/

Stand-Alone

Networking/

Stand-Alone

1,024

65,535

1,024

1.Card only

2.Card and PIN (4-digit PIN) +

3.Card or User address (5-digit) + Individual PIN (4-digit individual PIN) +

1.Card only

2.Card and PIN (4-digit public PIN= Arming PWD) +

3.Card or PIN (4-digit public PIN= Duress code)

1.Card only

2.Card and PIN (4-digit individual PIN) +

3.Card or PIN (4-digit individual PIN)

Yes

No

Yes

1,200

No

1,200

Yes

No

Yes

Yes

No

Yes

No

No

No

32

No

32

Yes

No

Yes

Mode 6, the number of users up to 65535, since it reads CARD CODE(5 digits) only, unlike that Mode4/Mode8 read SITE CODE and CARD CODE(10 digits).

If Access Mode setting to use the PIN, it need to external the K-series Readers.

Factory Reset by its commands

When the device is stand-alone (not networking)

Access programming mode → 20 016 → 24 064 → 26 00000 01023 1 → 28 000 → 29 29

※ Note: After the Master Code is changed, factory reset doesn’t restore the Master Code back to 123456.

Access Controller

V110713

Command List

Function

Entering programming mode

Command

PPPPPP

Exiting programming mode

Exiting programming mode and enabling arming status

Node ID setting (Connecting to 716E 00 NNN

Node ID setting (Connecting to PC directly without via 716E)

00 NNN VVV nnn

Mifare tag / card format (Optional)

Door relay time setting

Alarm relay time setting

Control mode setting

Arming delay time setting

Alarm delay time setting

Master card setting

Auto-open time zone setting

02 TTT

03 TTT

04 N

05 TTT

06 TTT

07 SSSSS EEEEE

Master code setting 09 PPPPPPRRRRRR

Setting

Suspend tag(M6) 10 SSSSS EEEEE

Delete tag(M4)

Set a sequence of cards as "read and access"

Active the suspended cards

11 SSSSS EEEEE

11 SSSSS EEEEE

Set the cards as Card mode OR PIN mode by user address

12 UUUUU PPPP

Set the cards as Card AND PIN mode by user address

13 UUUUU PPPP

M4: Duress code setting

M6: Public PIN setting (Card or PIN)

15 PPPP

Card number modification 16 UUUUU SSSSSCCCCC

M4: Arming pass code setting

M6: Public PIN setting (Card and PIN)

Door open waiting time

Set the card by induction

Reader additional setting

Lift control setting: multi-doors

Add/Delete tag by induction (M6 only)

AR-401ROsite number dip switch

Controller parameter setting

Controller time clock setting

17 PPPP

18 TTT

19 UUUUU QQQQQ

20 DDD

21 UUUUU S FFFFFFFF

22 N

23 NNN TTT

24 DDD

25 YYMMDDHHmmss

Anti-pass-back (Enable user) 26 SSSSS EEEEE N

Single floor setting

Dual door control/ Active or inactive arming for force open

Delete all tags

Enable the security trigger signal ( with AR-721RB)

27 UUUUU FF

28 DDD

29 29

34 064 (Enable)

34 000 (Disable)

01 N

08 N HHMMhhmm 7123456H

Description

PPPPPP=Master Code, default value= 123456

NNN=Node ID, range: 001~254

NNN=Node ID of Access Controller, VVV=Virtual 716E Node ID, nnn=Door number; range:001~254

N: 0=ISO14443A; 1=ISO14443B; 2=ISO15693;

3=I Code1; 4=I Code2

PS.1. Please select the compliance,first.

2. Make sure reader and card using the same compliance.

Mode

M4/M6/M8

M4/M6/M8

M4/M8

M4/M8

M4/M8

M4/M8

TTT=Door relay time 000= Output constantly

001~600=1~600 sec.

601~609=0.1~0.9 sec.

TTT=Alarm relay time 000= Output constantly 001~600=1~600 sec.

N=Mode 4=Mode4; 6=Mode6; 8=Mode8

TTT=Alarm relay time 001~600=1~600 sec.

TTT=Alarm delay time 001~600=1~600 sec.

SSSSS-EEEEE=00000-01023 (00000-03000 for AR-725H);

SSSSS=Starting user address; EEEEE=Ending user address

N= 0(1st time zone) / 1(2nd time zone)

HHMM= Starting time; hhmm= ending time

(i.e.: 08301200=08:30 to 12:00)

7123456H= 7 days of week (Sun/Mon/Tue/Wed/Thu/Fri/Sat)+ Holiday

(H= 0: disable; 1: enable); Holidays establish by the software.

PPPPPP=New master code

RRRRRR=Repeat the new master code

M4/M6/M8

M4/M6/M8

M4/M6/M8

M4/M6/M8

M4/M6/M8

M4/M8

M4/M6/M8

M4/M6/M8

SSSSS=Starting user address, EEEEE=Ending user address

SSSSS=Starting card number; EEEEE=Ending card number

SSSSS=Starting user address; EEEEE=Ending user address

Access mode: Card or PIN; UUUUU=user address;

PPPP=4-digit pass code 0001~9999

Access mode: Card and PIN; UUUUU=user address;

PPPP=4-digit pass code 0001~9999

PPPP=4-digit pass code (default value= 4321)

P.S. Duress code will be unavailable and become a public PIN at access mode “ Card or PIN” of M6

M4/M6/M8

M6

M4/M8

M4/M8

M4/M8

M4/M6/M8

M4/M8

UUUUU= User address; SSSSS=5-digit site code;

CCCCC=5-digit card code

M4/M6/M8

PPPP=4-digit pass code ( default value= 1234; disable Arming PWD=0000)

P.S. Arming PWD code will be unavailable and become a public PIN at access mode “ Card PIN” and of M6

M4/M6/M8

TTT=Door open waiting time: 001~600=1~600 sec.; default value: 15 sec. M4/M8

UUUUU=User address;

QQQQQ=Card quantity( 00001=Continuously inducting)

M4/M6/M8

Please refer to function default value for details.

M4/M6/M8

UUUUU=User address, S=4 sets of lift control(0~3); FFFFFFFF=8 assigned floor

(F=0: Disable, 1: Enable)

M4/M8

N=0(Delete tag); N=1(Add tag)

NNN=site number, TTT= relay time: 000~600=1~600 sec.

Please refer to function default value for details.

YYMMDDHHmmss: Year/ Month/ Day/ Hour/ Min./ Sec.

M6

M4/M8

M4/M6/M8

M4/M6/M8

SSSSS=Starting user address; EEEEE=Ending user address;

N=0/Enable; N=1/Disable; N=2/Initial

M4/M8

UUUUU=User Address; FF=Floor (01~32 floor)

Please refer to function default value for details.

M4/M8

M4/M6/M8

M4/M6/M8

To Change the "Door Lock" become the security trigger signal, when controller is connected with AR-721RB.

M4/M6/M8

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement