POWER FIST 2,800 Watt generator Owner's manual
Below you will find brief information for generator 2,800 Watt. This POWER FIST generator features a 6.0 HP engine, produces 2,300 watts of continuous power and 2,800 watts of peak power, has a 3.2 gallon fuel tank, and has a run time of approximately 8 hours.
PDF
Download
Document
Advertisement
Advertisement
8142564 FIST | 2,800 Watt Generator 's Manual Owner 3084052 Introduction WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE. * This product is for use in a consumer application (personal, residential or household usage) Use reasonable care in the operation and maintenance of the product as described in the owner's manual. * Merchandise that has become damaged or inoperative because of ordinary wear, misuse, cold, heat, rain, excessive humidity, freeze damage, use of improper chemicals, negligence, accident, failure to operate the product in accordance with the instructions provided, improper maintenance, use of unrecognized accessories, or unauthorized repair or alterations is the responsibility of the owner, as are costs associated with assembly, oil, adjustments or other installation and start-up costs. » Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period of use. are also the responsibility of the owner ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECTS, FAILURE OR MALFUNCTION OF THE PRODUCT IS NOT COVERED BY PRINCESS AUTO Safety Guidelines This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help to recognize this information. Please read the manual and pay attention to these sections. Save these important safety instructions * Read and understand all of these safety instructions. Be sure to retain them for future use. WARNING! WARNINGS INDICATE A CERTAINTY OR STRONG POSSIBILITY OF PERSONAL INJURY OR DEATH IF INSTRUCTIONS ARE NOT FOLLOWED. CAUTION: CAUTIONS INDICATE A POSSIBILITY OF EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT FOLLOWED. NOTE: NOTES GIVE HELPFUL INFORMATION WARNING! IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT. WHEN USING ANY TOOL, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE RISK OF PERSONAL INJURY. Carbon Monoxide When this machine is running. ensure that the area is well ventilated. Never run the engine in an enclosed area. Run the engine in an open area or with an exhaust evacuation system in an enclosed area. WARNING! THE EXHAUST CONTAINS POISONOUS CARBON MONOXIDE GAS THAT CAN CAUSE LOSS OF CONSCIOUSNESS AND MAY LEAD TO DEATH, Gasoline and Oil This product requires oil and fuel. Attempting to start the engine without oil will ruin the engine and void the warranty. Work in well ventilated areas. Keep cigarettes, flames or sparks away from the work area or where gasoline 1s stored. WARNING! GASOLINE IS EXTREMELY FLAMMABLE AND IS EXPLOSIVE UNDER CERTAIN CONDITIONS. KEEP OUT OF REACH OF CHILDREN. * Gasoline fuel and fumes are flammable and potentially explosive. Use proper fuel storage and handling procedures. Always have multiple class ABC fire extinguishers nearby. * Keep the generator and surrounding area clean at all times. * Fuel or oul spills must be cleaned up immediately. Dispose of fluids and cleaning materials as per any local, state 1 or federal codes and regulations. Store oily rags in a covered metal container. 3 * Never store fuel or other flammable materials near the generator, General Precautions WARNING! FAILURE TO FOLLOW THESE INSTRUCTIONS CAN RESULT IN SEVERE INJURY OR DEATH. CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS CAN ALSO RESULT IN DAMAGE TO THE TOOL AND/OR THE ITEM YOU ARE WORKING ON. * Do not smoke. or allow sparks, flames or other sources of ignition around the engine and fuel tank. Fuel vapors are explosive. * Keep grounded conductive objects. such as tools, away from exposed, live electrical parts and connections to avoid sparking or arcing. These events could ignite fumes or Vapors. * Do notretill the fuel tank while the engine is running or while the engine is still hot. Do not operate the generator with known leaks in the fuel system * Excessive buildup of unburned fuel gases in the exhaust system can create a potentially explosive condition. This buildup can occur after repeated failed start attempts, valve testing, or hot engine shutdown. If this occurs, open exhaust system drain plugs, it equipped, and allow the gases to dissipate before attempting to restart the generator. * Use only engine manufacturer recommended fuel and oil. Hot Components WARNING! ENGINE AND EXHAUST SYSTEM PARTS BECOME VERY HOT AND REMAIN HOT FOR SOME TIME AFTER THE ENGINE IS RUN. WEAR INSULATED GLOVES OR WAIT UNTIL THE ENGINE AND EXHAUST SYSTEM HAVE COOLED BEFORE HANDLING THESE PARTS. Power Output This generator is not designed to power sensitive electronic equipment (including computers and medical devices) without the addition of an approved line conditioner, which is sold separately. CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. Work Area Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Generators create sparks which may ignite the dust or fumes. Keep bystanders, children, and visitors away while operating a generator. Provide barriers or shields as needed. Electrical Safety Grounded tools must be plugged into an outlet properly installed and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Grounding provides a low-resistance path to carry electricity away from the user in the event of an electrical malfunction. Double insulated tools are equipped with a polarized plug where one blade is wider than the other. This plug fits in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install a polarized outlet. Do not change the plug in any way. Double insulation eliminates the need for the three-wire grounded power cord and grounded power supply system. Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators. There 1s an increased risk of electric shock if your body is grounded. Do not expose generator to rain or wet conditions. Water entering a generator will increase the risk of electric shock. Do not abuse the power cord. Keep power cords away from heat, oil, sharp edges, or moving parts. Replace damaged power cords immediately. Damaged power cords increase the risk of electric shock. When operating a power tool outside, use an outdoor extension cord marked “W-A” or “W”. These extension cords are rated for outdcor use, and reduce the risk of electric shock. All connections and conduits from the generator to the load must only be installed by trained and licensed electricians. and be in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. The generator must be earth-grounded for fixed installations in accordance with all relevant electrical codes and standards before operation. Do not attempt to connect or disconnect load connections while standing in water, or on wet or soggy ground. Do not touch electrically energized parts of the generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object. Connect the generator only to a load or electrical system (120 volt) that is compatible with the electrical characteristics and rated capacities of the generator. Before servicing equipment powered by the generator, disconnect the equipment from its power input. Keep all electrical equipment clean and dry. Replace any wiring where the insulation is cracked, cut abraded or otherwise degraded. Replace terminals that are worn, discolored, or corroded. Keep terminals clean and tight. Insulate all connections and disconnected wires. Guard against electric shock. Prevent body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerator enclosures. Personal Safety * Stay alert. Watch what you are doing, and use common sense when operating a generator. Do not use generator while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating generators may result in serious personal injury. * Dress properly. Do not wear loose clothing or jewelry. Contain long hair. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewellery, or long hair can be caught in moving parts. e Avoid accidental starting. Make sure the power switch is in its “OFF” position, and disconnect the spark plug wire when not in use. * Remove adjusting keys or wrenches before turning the generator on. A wrench or a key that 15 left attached to a rotating part of the generator may result in personal injury. * Do not overreach. Keep proper footing and balance at all times. * Use safety equipment. Always wear eye protection. Wear ANSI approved safety impact eye goggles. Dust mask, non-skid safety shoes, hard hat, or hearing protection must be used for appropriate conditions. * Do not force the generator. Use the correct generator for your application. The correct generator will do the job better and safer at the rate for which it is designed. * Do not use the generator if the power switch does not turn it on or off. Any generator that cannot be controlled with the power switch is dangerous and must be replaced. Generator Use and Care * Make sure the power switch 1s in its “OFF” position and disconnect the spark plug wire before making any adjustment, changing accessories, or storing the generator. Such preventive safety measures reduce the risk of starting the generator accidentally. * Store ¡dle generators out of reach of children and other untrained persons. Generators are dangerous in the hands of untrained users. » Maintain generators with care. Do not use damaged generator. Tag damaged generators “Do not use” until repaired. * Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the generator's operation. If damaged, have the generator serviced before using. Many accidents are caused by poorly maintained generators. * Use only accessories that are recommended by the manufacturer for your model. Accessories that may be suitable for one generator may become hazardous when used on another generator. Servicing * Maintain labels and name plates on the generator and engine. These carry important information. * Generator service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel could result in a risk of injury. * When servicing a generator, use only identical replacement parts. Follow all appropriate instructions in this manual. Use of unauthorized parts or failure to follow maintenance instructions may create a risk of electric shock or injury. Heart Pacemakers WARNING! PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USING THIS PRODUCT. ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO A HEART PACEMAKER COULD CAUSE INTERFERENCE TO OR FAILURE OF THE PACEMAKER. Installation e Ensure installation meets all applicable safety. and local and national electrical codes. Have installation performed by a qualified. licensed electrician and building contractor. * All electrical work, including the earth-ground connection, should be completed by a licensed electrician. * Any separate fuel storage or generator supply facility must be built or installed in full compliance with all relevant local, state, and federal regulations. « If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It should not be run outdoors without protection to the generator and wiring conduit. « The generator weighs 100 Ibs (approx). Two or more people should assist when moving or lifting this product. Never lift the generator using the engine or alternator lifting lugs. Connect lifting equipment to the frame of the generator * Before lifting the generator, ensure the lift rigging and supporting structure are in good condition, and are rated to lift such a load. * Keep all personnel away from the suspended generator during relocating. * The supporting floor/ground surface should be level and strong enough to safely hold the weight of the generator. If the floor/grounded surface is not level, strong cross members should be placed under the full length of the generator frame at its low side. e For trailer installation, the generator should be mounted on the center point of the trailer, over the wheels. The trailer must be capable of supporting the weight of the generator and all contents (tools, etc.) * Install sound-and weather-proofing only when it is not raining or snowing to avoid trapping moisture within the generator s area. Mechanical * Always make sure the power switch is in its “OFF” position. Disconnect the spark plug wire, and allow the engine to completely cool before carrying out maintenance. * Check for damaged parts. Before using the generator, any part that appears damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment and binding of moving parts, any broken parts or mounting fixtures. and any other condition that may affect proper operation technician. * The generator is designed with guards for protection from moving parts. In any case, care must still be taken to protect personnel and equipment from other mechanical hazards when working around the generator. * Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. « Keep hands, arms, long hair, loose clothing, and jewellery away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly. * Keep access doors on enclosures closed and locked when access 1s not required. * When working on or around the generator always wear protective clothing including ANSI approved safety gloves, safety eye goggles, and safety hat. * Do not alter or adjust any part of the generator that is assembled and supplied by the manufacturer. * Always follow and complete scheduled engine and generator maintenance. Noise * Prolonged exposure to noise levels above 68 dB is hazardous to hearing. Always wear ANSI approved ear protection when operating or working around the generator when it is running. Chemicals * Avoid contact with hot fuel, oil, exhaust fumes. and hot solid surfaces. * Avoid body contact with fuels, oils, and lubricants used in the generator. If swallowed, seek medical treatment immediately. Do not induce vomiting if fuel is swallowed. For skin contact. immediately wash with soap and water. For eye contact, immediately flush eyes with clean water and seek medical attention. Extension Cord If an extension cord (not included) is used, make sure to use only UL approved cords having the correct gauge and length according to the following table: Fuel tank Amperage 0 to 50 ft 50 to 100 ft 15 -20A 10 gauge [0 gauge Battery ; Centred Pan This product does not need a battery. me Assembly \ 3 1 Sul Start No assembly 1s required. Friel Switch Operation NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW. CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE FILLED WITH OIL OF A HIGH QUALITY SAE 10W30 GRADE Ness A ENGINE OIL. TO DO SO, UNSCREW AND REMOVE THE ENGINE'S - OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE. FILL THE ENGINE'S CRANKCASE UNTIL THE OIL LEVEL IS LEVEL WITH THE UPPER MARKED LINE ON THE DIPSTICK. THEN SCREW THE DIPSTICK BACK INTO THE OIL FILL HOLE. FUEL TANK CAP Before Starting the Generator — |. Check that the engine power switch is in its “OFF” position. 2. Before the first use. remove the fuel tank cap and fill the fuel tank with unleaded gasoline. When fueling, be sure that the fuel strainer is in place. Replace the fuel tank cap. Thereafter, check the engine's fuel gauge for the amount of unleaded gasoline in the fuel tank. If necessary, refill the fuel tank with unleaded gasoline; the generator must be turned off and cooled down before refilling the fuel tank. Starting 1. Turn the engine switch to the ON position. The engine switch enables and Sis disables the ignition system. dE OFF: To stop the engine ON: To run the engine 2. The fuel valve is located under the fuel tank. When the valve lever 1s in the ON position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to return the fuel valve lever to the OFF position after stopping the engine. 3. To start a cold engine, move the choke lever to the CLOSED position. To restart a warm engine, leave the choke lever in the OPEN position. The choke lever opens and closes the choke valve in the carburetor. The CLOSED position enriches the fuel mixture for starting a cold engine. The OPEN position provides the correct fuel mixture for operation after starting. and for restarting a warm engine. 4. Operate the Recoil Starter: Pull the starter grip lightly until you feel resistance, then pull briskly. Return the starter grip gently. Pulling the starter grip operates the recoil starter to crank the engine 5. If the choke lever has been moved to the CLOSED position to start the engine, gradually move it to the OPEN position as the engine warms up. Stopping Engine 1. Turn the engine switch to the OFF position. 2. Turn the fuel valve lever to the OFF position. When the engine 1s not in use, leave the fuel valve lever in the OFF position to prevent carburetor flooding and to reduce the possibility of fuel leakage. Powering 120 Volt AC Tools And Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage capacity (120V AC @ 19 AMPs) 1s adequate to supply all electrical loads that the unit will power. If powering exceeds the generator’s capacity, it may be necessary to group one or more of the tools and/or equipment for connection to a separate generator. CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. 2. Once the generator is running, simply connect the power cords of 120 volt AC powered tools and equipment into the 120 volt AC dual outlets. NOTE: THE GENERATOR FEATURES AN AC NON-FUSE CIRCUIT BREAKER TO PROTECT THE AC CIRCUIT IN CASE OF AN OVERLOAD. SHOULD AN OVERLOAD OCCUR, THE BREAKER WILL “TRIP” TO ITS “OFF” POSITION, CAUSING THE GENERATOR TO AUTOMATICALLY SHUT DOWN. IN THIS CASE. REFER TO ABOVE IN THIS POSITION. THEN, RESET THE CIRCUITRY SYSTEM BY TURNING THE CIRCUIT BREAKER TO ITS “ON” POSITION. RESTART THE GENERATOR AND CONTINUE POWERING THE REMAINING TOOLS AND EQUIPMENT. 3. Note: The Generator features an AC Non-Fuse Circuit Breaker “OFF” position. Turn the fuel valve to its “OFF” position. 4. Disconnect all electrical powered tools and equipment from the generator's 120 volt AC duel outlets. >. After the engine and generator have completely cooled, store generator in a safe, clean, dry location (if not already installed). The machine does not have a 12V DC output! ida Spark Plug Service 1 * In order to service the spark plug, you will need a spark plug wrench (commercially available). — * Recommended spark plugs: NHSP LD F7TC or NGK BPRGES but we recommend | our OEM spark plug. To ensure proper engine operation, the spark plug must be Lx Sd properly gapped and free of deposits. YT AO: |. Remove the spark plug cap. 2. Use a spark plug wrench to remove the spark plug. 3. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the spark plug with a wire brush if it is to be reused. 4. Measure the plug gap with a feeler gauge. 5. Check that the spark plug washer is in good condition. 6. After the spark plug is seated, tighten with a spark plug in by hand to prevent cross-threading. 7. Atter the spark plug is seated, tighten with a spark plug wrench to compress the washer. NOTE: THE SPARK PLUG MUST BE SECURELY TIGHTENED. AN IMPROPERLY TIGHTENED SPARK PLUG CAN BECOME VERY HOT AND COULD DAMAGE THE ENGINE. NEVER USE SPARK PLUGS WHICH HAVE AN IMPROPER HEAT RANGE. USE ONLY RECOMMENDED SPARK PLUS OR EQUIVALENT. Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTION, MAINTENANCE, OR CLEANING. * Before each use, inspect the generator. Check for: - Loose screws - Misaligned or binding moving parts - Cracked or broken parts - Damaged electrical wiring - Any other condition that may affect safe operation. * It an engine problem occurs, have it checked by a qualified service technician before further use. Do not use damaged equipment. » Before each use, make sure the engine’s oil and gas levels are adequate. If necessary, fill the crankcase until the oil level is even with the oil fill hole and/or fill the fuel tank. , * Before each use, remove all debris with a soft brush, rag, or vacuum. Li. , * Lubricate all moving parts using a premium quality, lightweight machine oil. * Every 50 hours of use, drain the old engine oil and replace with a high a high quality SAE 10W30 grade engine oil. * Every 300 hours of use, have a qualified, certified technician perform thorough maintenance on the generator and engine. ED in E * For long term storage, either drain fuel into suitable container or add a fuel preservative/stabilizer (not included) to prevent fuel breakdown. Upsear Leva! Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATORS CAPACITY, IT MAY BE NECESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPARATE GENERATOR . Electrical and other permits may be required for the installation of emergency power systems. Investigate your local building and electrical codes before installing this unit. Installation must be completed by licensed contractors. WARNING! THE GENERATOR WEIGHS APPROXIMATELY 100 POUNDS. USE CARE AND THE PROPER LIFTING OR HOISTING EQUIPMENT WHEN MOVING IT TO THE INSTALLATION LOCATION. ALWAYS CONNECT HOIST LINES TO THE FRAME OF THE GENERATOR. General Location * Маке sure to locate and install the generator outdoors where cooling air is readily available. * install the generator so that the air inlets and outlets are not blocked by obstructions such as bushes, trees. or snow drifts. Locating it in the path of heavy winds or snowdrifts may require the placement of a barrier for protection. In normal weather conditions, the air vent should face the prevailing wind direction. * Install the generator on a concrete slab or other area where rain drainage or flood waters can not reach it. * Generator placement should allow four feet of access to all sides for maintenance. * Place the generator as close as possible to the electrical tools and equipment being powered to reduce the length of extension cords. Supporting and Mounting Mount the generator on a concrete slab capable of supporting the weight of the generator. The slab must extend on all sides beyond the frame by at least one foot. Contact a cement contractor for slab specifications if necessary. Attach the frame to the concrete slab using 3/8" diameter expansion anchor bolts (not supplied). Grounding NOTE: IT IS RECOMMENDED THAT ONLY A TRAINED AND LICEN SED ELECTRICIAN PERFORM THIS PROCEDURE Connect a #6 AWG grounding wire (not included) from the ground connector (8) on the generator to a grounding rod (not included) that has been driven at least 24 inches deep into the earth. The grounding rod must be an earth- driven copper or brass rod (electrode) which can adequately ground the generator. specifications AC electrical Current Output Continuous/rated Wattage Peak Wattage Outlet DC electrical no Gasoline engine Horsepower Type Displacement Oil capacity EPA approved Fuel Type Capacity Running time Fuel gauge Weight Approximate weight 120V AC @ 19A 2,300 W 2,800 W 2 @ 120V AC, 3 spring grounded 6.0 HP 4-cycle OHV air-cooled recoil start 171cc 0.6 quart (0.56 liter) yes Unleaded gasoline 3.2 gallons (12 liters) 8 hours (approx.) included 98 lbs Parts List Z © Ls 9 ND —= mes KE) DE =] CN СА |2 13 14 [5 16 17 18 19 20 21 da J La mar 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 Description Hex bolt with flange M6x10 Start cover Nut M14 Washer 14mm Start shaft sleeve Ventilating cover Hex bolt Fly wheel Ignition Hex bolt M6x10 Flat screw M6x15 Terminal box Frame Hex nut with flange Damper Fuel tank pad Switch O1l pipe clamp Oil input pipe Fuel meter Fuel tank cap Fuel strainer Fuel tank Bolt with flange M6x8 Flat washer Crankshaft seal Tank Bolt M10x1.5x16 Washer Choke lever Choke lever spring clamp Choke lever seal Choke lever washer Square nut Swing pole Link rod Spring clamp Hex bolt M6x30 Spring Adjust plate Adjust slice Spring Phillips screw M6x35 Bearing 6205 Half round key 4x8, 5x16 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 50 5 | 82 83 84 65 86 87 00 89 90 Description Crankshaft assembly Locating ring Cam shaft Valve lifter Hex bolt with flange M7x35 Connecting rod cap Connecting rod Piston pin Piston pin clip Piston Piston ring Gasket Piston pin Exhaust valve Bolt M6x25 Washer Bolt M6x25 Intake valve Cylinder head Bolt M6x85 Spark plug Seal Valve spring Valve spring retainer Valve cotter Push rod Push rod guide Washer 6mm Bolt Rocker arm Adjuster Hex bolt M8x0.75 Gasket Inside sheet Bolt Gasket Cylinder head cover Cylinder cover Bolt M6x12 Gas pipe Gasket Gasket Carburetor Gasket Air filter case No 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 Description Plate Hex nut M6 Element fitting plate Air filter Air filter cover Screw M6x12 Bolt M6x10 Bolt M6x10 Gasket Speed regulating wheel Washer Crank case cover Hex bolt with flange M6x12 Locating sheet Hex bolt with flange M6x12 Oil level gauge Ring seal Oil cover Hex bolt M8x35 Rotor Bearing 43x17x12 Stator Stator cover Rear frame Locating sheet Bolt M6x105 Rear frame cover Hex bolt with flange M6x10 Wire rack Screw M5x12 Washer Smm Washer 5mm Bolt M8x170 Washer 8 mm Washer 8 mm Hex bolt with flange M8x16 Hoop Muffler net Muffler screen Shockproof bar Muffler cover Hex bolt with flange M6x8 Hex bolt with flange M8x16 Muffler Parts Diagram ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- 6.0 HP engine
- 2,300 watts of continuous power
- 2,800 watts peak power
- 3.2 gallon fuel tank
- 8 hours run time
Frequently asked questions
Unleaded gasoline.
Approximately 8 hours.
2,800 Watts.
2,300 Watts.
0.6 quart (0.56 liter)