Commercial Air Conditioning Systems Quietly Superior Heat Pumps 1 Functionality, versatility and comfort for every environment Who is Mr. Slim? Mr. Slim acquires its name for its slender, install-anywhere design. Developed over 40 years ago in Japan to fit the unique living circumstances of limited space, dense population and expensive energy costs, it is now adopted the world over for its space saving, quiet and energy-efficient design that is built to last. A wide variety of indoor unit designs and outdoor unit capacities ensures the flexibility to meet the most challenging of heating and cooling needs for domestic and commercial applications. The Mitsubishi Electric Mr. Slim Series of small to medium-sized split-type room air conditioners offers the convenience of being compact yet powerful; a combination ensuring excellent performance and easy installation. Available in a variety of capacity and design combinations, the Mr. Slim Series is ideal for creating a best match system for all of your heating and cooling requirements. Inverter-based units provide industry-leading quiet operation and high efficiencies, ensuring comfortable working and living environments. 2 Designed for Efficiency Mitsubishi Electric’s Power Inverter Systems Drastically Reduce Power Consumption Silent Control To better meet the needs of shops and offices, our outdoor when the outdoor temperature drops, resulting in quiet, low- units offer many energy saving features. Select the model to noise operation. Operating noise is reduced by 3dBA. Fan speed during cooling operation is automatically reduced best match your needs from our expanded model range. “Silent Control” reduces sound further Model RP140 (cooling) Day 50dBA Night 47dBA 3dBA REDUCTION Outdoor temperature: 35°C Outdoor temperature: 25°C R22 R410A Inverter units (PUHZ-RP) Non-inverter units 71 class 100 class 125 class 140 class PUHZ-RP100/125/140/170 PUHZ-RP71 52 55 55 56 Normal dBA dBA dBA dBA 47 49 50 50 Low-noise Mode dBA dBA dBA dBA 44 46 47 47 dBA dBA dBA dBA Longer Maximum Piping Length Side-flow Outdoor Units As a result of increasing the volume of refrigerant, piping Outdoor units with operating capacities of up to 20kW have length has been increased to a maximum of 75m, expanding been unified to a side-flow configuration, providing greater the range of layout possibilities for unit installation. versatility in installation locations. The compact footprint Max. Piping Length of these outdoor units also allows them to be used for Max. Height Difference Max. Piping Length RP71 30m 50m RP100/125/140/170 30m 75m applications requiring large capacity heating and cooling. High Power More Power for Faster Heating/Cooling Wider Performance Range The maximum operating heating/cooling capacities of the Operation is now possible at lower speeds, thus cutting Mr. Slim Power Inverter units have been improved (compared energy losses produced by the repeated On/Off operation to conventional non-inverter models) when operating in either of non-inverter models. Comfort is improved while power low or high outdoor temperatures. consumption is reduced. Heating capacity (kW) 4-way ceiling cassette R22 Non-inverter Heating capacity ranges R410A Power Inverter max. (PUHZ-RP) 71 class 8.4 10.2 121% 100 class 10.4 14.0 135% 125 class 14.0 16.0 114% 140 class 16.1 18.0 112% 71 class 3.5-10.2 kW 100 class 4.5-14.0 kW 125 class 5.0-16.0 kW 140 class 5.7-18.0 kW 0 2 Cooling capacity (kW) 4-way ceiling cassette R22 Non-inverter 4 6 8 10 Cooling capacity ranges R410A Power Inverter max. (PUHZ-RP) 71 class 7.7 8.1 105% 100 class 9.7 11.4 118% 125 class 12.4 14.0 113% 140 class 14.0 15.3 109% 4-way ceiling cassette 12 14 16 18kW 16 18kW 4-way ceiling cassette 71 class 3.3-8.1 kW 100 class 4.9-11.4 kW 125 class 5.5-14.0 kW 140 class 6.2-15.3 kW 0 2 4 6 8 10 12 14 3 Advanced Energy-saving Technologies Highly Efficient Fan and Grille for Outdoor Unit Highly Efficient Heat Exchanger Both the shape of the fan and grille in Mr. Slim Series Increasing both the density and surface area of Mr. Slim Series outdoor units have been redesigned, helping increase airflow heat exchangers has led to an improvement in overall heat- capacity and create a more efficient heat exchange, all while exchange efficiency. maintaining the same operating noise level. Outdoor Unit Fan Opening Increased (PUHZ-RP100~170) High-density Heat Exchanger (PUHZ-RP100~170) A reduction in pipe diameter from 9.52 to 7.94mm increases The diameter of the outdoor unit fan opening has been heat exchanger density. As a result greater heat exchange is increased from 490 to 550mm. As a result, airflow realised. capacity has been increased while maintaining the same fan rotation speed. 2 lines, 52 columns 2 lines, 64 columns (RP100~140) Opening increased from 490 to 550mm in diameter Heat Exchange Surface Area Increased (PUHZ-RP100~170) By extending the heat exchanger horizontally the total heat Redesigned Grille Shape The shape of the air outlet grille has been redesigned to reduce pressure loss, in turn improving heat exchange surface area is increased, again resulting in greater overall heat exchange. exchange performance. Increase in heat exchanger surface area Heat exchanger Heat exchanger <PUHZ–RP-HA> Inflexed Fan (PUHZ-RP100~170) Adoption of a fan with improved ventilation characteristics and a newly designed rear edge that suppresses wind turbulence raises fan operation efficiency. <PUHZ–RP-KA> Heat Interchanger (HIC) Added (PUHZ-RP140) An HIC circuit has been added to improve energy efficiency during cooling operation. To achieve this liquid refrigerant is rerouted, transformed into a gas state, and injected back into the system to increase the overall pressure of refrigerant being sent to the compressor. This results in reduced loading on the compressor and an overall increase in efficiency. Cooling operation Indoor HEX LEV B A Heat interchanger (HIC) w/o HIC circuit w/ HIC circuit 4 Outdoor HEX Power receiver A Fan rear edge Compressor LEV A Heat interchanger LEV C (HIC) Increasing the pressure of the refrigerant sent to the compressor reduces the compression load Advanced Technology for High Efficiency Leading-edge Technology, High Efficiency Assured Reluctance DC Rotary Compressor (PUHZ-RP71) DC Fan Motor All reluctance DC motors in Mr. Slim PUHZ-RP71 outdoor A highly efficient DC motor has been installed to drive the units incorporate a rotor equipped with powerful neodymium outdoor unit fan, resulting in up to 60% higher efficiency when magnets. The magnetic and reluctance torque produced by compared to an equivalent AC motor. these magnets results in more efficient operation. Vector-wave Eco Inverter This inverter monitors the varying compressor motor frequency DC compressor motor (rotor) and creates the most efficient waveform for the motor speed. As a result, operating efficiency in all speed ranges is improved, less power is used, and annual electricity costs are reduced. Smooth AC Wave Pattern The inverter has been made more compact by inserting the Neodymium magnets Magnetic torque + Reluctance torque Highly Efficient Scroll Compressor (PUHZ-RP100~170) circuitry inside a synthetic resin moulding. To ensure quiet operation, soft PWM (pulse width modulation) control is used to prevent the metallic whine associated with conventional inverters. Sine-wave drive soft PWM Higher efficiency has been achieved by adding a frame compliance mechanism to the DC scroll compressor. The mechanism allows movement in the axial direction of the frame supporting the cradle scroll, thereby greatly reducing the leakage and friction loss, and ensuring extremely high efficiency at all speeds. Power Receiver and Twin LEV Control Fixed scroll Thrust gas power: minimum Leaking loss: minimum Mitsubishi Electric has developed a power receiver and twin linear expansion valves (LEVs) that optimise the performance of the compressor. By ensuring optimum control Thrust friction loss: minimum Secondary back-pressure chamber minimises thrust friction loss. Frame Cradle scroll in response to the operating waveform and outdoor temperature, this technology is tailored to the characteristics of the new refrigerant to enhance operating efficiency. Primary back-pressure chamber minimises leaking loss. 5 MA Wired Wall Controller PAR-32MAA The PAR-32MAA is now easier to read thanks to the Display Example [Operation Mode] use of a full dot liquid-crystal display with backlight. Full Dot LCD PAR-32MAA Control panel operation in eight different languages Adoption of a menu format that has reduced the number of operating buttons has also ensured •English •Spanish •Italian •German •French •Russian •Portuguese •Swedish increased ease of use. New Simple MA Remote Controller Backlit LCD PAC-YT52CRA Pressing the Liquid-crystal display (LCD) with backlight for operation Multi Language Display button will switch the vane direction. in dark conditions. Flat Back The slim and flat-back shape makes installation easier without requiring a hole in the wall. Thickness is 14.5mm or less. Vane Angle Setting The vane button has been added to allow users to change the airflow direction (ceiling cassette and wall-mounted units). Zone Controller • Adjustable vane directions vary depending on the indoor unit model to be connected. • If the unit has no vane function, the vane direction cannot be set. In this case, the vane icon flashes when the button is pressed. PAC-ZC40(H/L)-E/PAC-ZC80(H/L)-E The PAC-ZC40~80 Zone Controller brings expanded functionality and interaction to realise even greater energy savings. With the ability to control up to 8 zones*, and equipped with automatic unloading/ramping and three built in sensor functions (temperature, occupancy, brightness), the Zone Controller brings intuitive, yet simple control to a whole new level. Temperature Sensor Sensing the return air of the indoor ducted unit is not always ideal. With an inbuilt thermostat (PAR-ZC01ME-E Wall Controller) the Zone Controller allows the actual usable space temperature to be measured, offering a more realistic and timely temperature measurement where it is needed most. Occupancy Sensor Incorporating a built in occupancy sensor, the Zone Controller (via the PAR-ZC01ME-E Wall Controller) constantly monitors the usable area to detect vacancy. Once detected, the Zone Controller uses internal functions to implement one of 4 user defined energy-save control options to reduce energy consumption; turn the unit on/off, lower the fan speed, temperature offset, or turn user designated zones on/off. Brightness Sensor Working in conjunction with the Occupancy Sensor, the Brightness Sensor can be set to maximise energy savings when it detects user defined “Light” or “Dark” conditions (lux values). Backlit LCD Touch Screen Features a liquid-crystal display (LCD) with backlight for operation in dark conditions. For ease of use the user defined coloured LED indicator (at the bottom of the controller) lights up to indicate the current operation mode i.e. red for heating, blue for cooling, green for night setback. Optional Wi-Fi Control Advanced temperature monitoring and management is available with the addition of the award winning Mitsubishi Electric Wi-Fi Control. Now you can control, monitor and schedule which zones your ADVANCED ducted heat pump is controlling in real time from anywhere via your smart phone, tablet or online account. OPTIONAL UPGRADE *PAC-ZC80 only. PAC-ZC40 only allows control of 4 zones. Compatible with either 24V or 240V damper options. Optional: 1x additional PAR-ZC01ME-E controller and 2x thermistors (PAC-SE41TS-E) can be installed. 6 Operation Control Functions Energy Efficient Control: PAR-32 & PAC-ZC Only Energy Saving Schedule Night Setback Precise control of power consumption (PAR-32 Only) Keep desired room temperatures automatically Incorporating advanced Energy Saving Scheduling, the This function monitors the room temperature and automatically PAR-32MAA Wired Wall Controller allows complete energy activates heating mode when the temperature drops below the management optimisation. System capacity can be adjusted preset minimal temperature setting. It has the same function (to 0, 50, 60, 70, 80 or 90% of maximum capacity) to reduce for cooling, automatically activating cooling mode when the total energy consumption. Additionally, up to 4 start/finish temperature rises above the preset maximum temperature patterns can be set per day to ensure optimal energy efficiency setting. without compromising comfort. Operation Lock Fixed temperature setting promotes energy savings Setting Pattern Example Start Time Finish Time Adjusted Capacity Level In addition to operation start/stop, the operation mode, temperature setting and airflow direction can be locked. 8:15 > 12:00 80% 12:00 > 13:00 50% an appropriate temperature is constantly maintained, leading 13:00 > 17:00 90% to energy savings. This feature is also useful in preventing 17:00 > 21:00 50% erroneous operation or tampering. Unwanted adjustment of temperature settings is prevented and Recommended for office, school, halls, hospital, computer server facility. Temperature Range Restriction Auto-Off Timer Prevents overheating/overcooling Using a temperature that is 1°C lower/higher for heating/ Turns heating/cooling off automatically after preset time elapses cooling results in a 10% reduction in power consumption.* When using the Auto-Off Timer, even if you forget to turn the Temperature Range Restriction limits the maximum and minimum temperature settings, contributing to the prevention of overheating/overcooling. unit off, operation stops automatically after the preset time elapses, thereby preventing wasteful operation. The AutoOff Timer can be set in 10 minute units, in a range between *In-house calculations. 30 minutes and 4 hours. This eliminates all anxiety about forgetting to turn the unit off. Cooling/Dry Setting example of minimum temp. in 25°C 19°C 30°C Possible temperature range setting 25°C Lower temperature limit Lower temperatures cannot be selected 30°C To prevent excessive cooling Recommended for office, restaurant applications. Recommended for meeting room, changing room applications. Weekly Timer Set up to 8 on/off patterns per day including temperature control The Weekly Timer enables the setting of operation start/stop times and the adjustment of temperature as standard features. Up to 8 patterns can be set per day, providing operation that matches the varying conditions of each period, such as the Auto-Return Prevents wasteful operation by automatically returning to the preset temperature after specified operating time After adjusting the temperature for initial heating in winter number of customers in a store. Weekly Timer cannot be used when On/Off Timer is in use. Setting Example (restaurant in summer time) Preparation 26 the temperature setting to its original value. The Auto-Return function automatically resets the temperature back to the original setting after a specified period of time, thereby preventing overheating/overcooling. The Auto-Return activation time can be set in 10-minute units, in a range between 30 and 120 minutes. Auto-Return cannot be used when Temperature Range Restriction is in use. Temperature setting (°C) or cooling on a hot summer day, it is easy to forget to return 1 Busy hours Set to lower temperature Off-peak hours 7 25 Opening time 2 24 4 5 3 23 8 Closing time 6 Lunch time Dinner time 8-pattern setting 22 0 Set to higher temperature 10 12 14 16 18 20 Necessary to change temperature settings for cooling/heating times. *Joint research conducted with Japan Facility Solutions, Inc. 22 24 Time (hr) 7 Installation/Maintenance Support Functions Manual Vane Angle Setting Automatic Grille Lowering Operation (4-way ceiling cassette) (Optional PLP-6BAJ) Direction of vertical airflow for each vane can be set Easily raise/lower panels using the remote controller All Deluxe PLA Cassettes allow the vertical airflow direction for each individual vane to be manually adjusted/set. As a result, draughts can be minimised without compromising system performance. Seasonal settings such as switching between cooling and heating can be easily changed as well. In conjunction with the optional PLP-6BAJ grille, automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance. Inspection Guidelines Once Smooth Maintenance is completed a table of information is displayed. This information can then be Smooth Maintenance manually plotted onto the two graphs (heating and cooling) Outdoor unit data can be accessed, enabling fast maintenance to see if the unit is operating normally (according to Japanese standard conditions). Using Stable Operation Control (fixed frequency) of the Smooth Operation Maintenance function, the operating status of the inverter can be checked easily via the screen on the remote controller. Item ( 6 OU TH4 temp.) – ( 7 OU TH6 temp.) Cooling ( 9 IU air temp.) Temp. difference Smooth Maintenance Function Operating Procedure – (10 IU HEX temp.) ( 6 OU TH4 temp.) – (10 IU HEX temp.) Heating (10 IU HEX temp.) (°C) Select maintenance mode Activate Stable Operation 45 40 Cooling operation Inspection C 35 Data is displayed Heating operation 30 9 10 25 20 Normal 10 35 Inspection C Filter inspection 20 5 10 20 30 40 50 60 70 80 6 25 7 Normal Inspection B 10 Inspection A 5 9 15 Inspection B 10 0 (°C) 45 40 30 Filter inspection 15 Display information (11 items) – ( 9 IU air temp.) (°C) 0 Inspection A 10 20 30 40 50 60 70 80 (°C) 6 10 Compressor Result 1 COMP. current (A) 2 COMP. run time (hr) 3 COMP. ON/OFF (times) Normal Normal operating status. 4 COMP. frequency (Hz) Filter inspection Filter may be blocked.*1 Outdoor Unit Capacity is reduced. Detailed inspection is necessary. 5 Sub cool (°C) Inspection B Refrigerant level is low. 6 OU TH4 temp. (°C) Inspection C Filter or indoor unit heat exchanger is blocked. 7 OU TH6 temp. (°C) 8 OU TH7 temp. (°C) Indoor Unit 9 IU air temp. (°C) 10 IU HEX temp. (°C) 11 IU filter operating time* (hr) *IU filter operating time is the time elapsed since filter was reset. 8 Inspection A *1 Due to indoor and outdoor temperatures, “Filter inspection” may be displayed even if the filter is not blocked. •The above graphs are based on trial data. Results may vary depending on installation/temperature conditions. •Stable operation may not be possible under the following temperature conditions: a) In cooling mode when the outdoor induction temperature is over 40°C or the indoor induction temperature is below 23°C. b) In heating mode when the outdoor induction temperature is over 20°C or when the indoor induction temperature is over 25°C. •If the above temperature conditions do not apply and stable operation is not achieved after 30 minutes has passed, please inspect the units. •The operating status may change due to frost on the outdoor heat exchanger. Rotation, Back-Up and 2nd Stage Cut-In Functions Rotation and Back-Up Functions (PAR-32MAA) With the ability to set rotation and/or backup functionality, Mr. Slim Series systems are the perfect solution for future proofing your comfort. Setting main and sub units to take turns operating, according to a rotation interval setting, increases overall system longevity. Meanwhile setting the Back-Up function ensures automatic redundancy in the event of unit malfunction. System Image Main Unit O/U-1 O/U-2 I/U-1 I/U-2 O/U:Outdoor unit Sub Unit I/U:Indoor unit R/C:Wired remote controller R/C 2nd Stage Cut-In Function The 2nd Stage Cut-In Function is perfect for applications where cooling load requirements fluctuate. As this load requirement increases above the desired setting, standby units are triggered into operation to ensure constant provision of the optimum level of comfort in the most energy efficient manner. Once the room temperature falls 4°C, 6°C, or 8°C below the predetermined setting, the standby unit ceases to operate to ensure excess cooling does not compromise comfort. System Constraint The 2nd Stage Cut-In Function is only available in cooling mode. Easy Maintenance Operation Pattern Back-Up Function only Error occurs on main unit. Main > Sub Start operation Main Unit I/U-1 Run Abnormal condition Sub Unit I/U-2 Stop Run Rotation Function & Back-Up Function Start operation Main Unit I/U-1 Run Sub Unit I/U-2 Stop Main>Sub 1-28 DAYS Main>Sub Error occurs on main unit. Main > Sub Stop Run Abnormal condition Run Stop Run 1-28 DAYS (Ex: When the request code is “313”, each unit operates alternately in daily cycle.) Operation Pattern (when cooling) 2nd Stage Cut-In Function Start operation Main Unit I/U-1 Run Sub Unit I/U-2 Stop Room temp. ≥ Set point Sub unit starts operation Room temp. ≥ Set point -4°C Sub unit stops Stop (Mr. Slim Power Inverter only) Operation of Mr. Slim Power Inverters is almost maintenancefree. Now you can monitor operation data of the indoor and outdoor units via the PAR-32MAA Wired Wall Controller. This controller also lets you view the operating frequency, allowing easier inspection/diagnostics. Easy Maintenance Information Compressor Indoor Unit Outdoor Unit 1 Accumulated Operating time (×10hr) 4 Heat exchanger temperature (˚C) 7 Intake-air temperature (˚C) 2 Number of ON/ OFF times (×100 times) 5 Discharge temperature (˚C) 8 Heat exchanger temperature (˚C) 3 Operating current (A) 6 Outdoor-air temperature (˚C) 9 Filter operating time* (hr) Refrigerant Leakage Check All Mr. Slim Power Inverter units come equipped with a useful new “Refrigerant Leakage Check” function. Using a wired remote controller, it is easy to check if refrigerant has been lost over a long period of use. This reduces service time and gives an added sense of safety. *The filter operating time is the time elapsed since the filter button was reset. 9 Product Line-Up 4-WAY CEILING CASSETTE SLZ COMPACT BULKHEAD p.18 PLA p.12 SEZ CEILING SUSPENDED p.18 PCA 2.5kW SLZ-KA25VAQ(L) 3.5kW SEZ-KD35VAQ 5.0kW SLZ-KA50VAQ(L) SEZ-KD50VAQ PCA-RP50KAQ PLA-RP60BA SEZ-KD60VAQ PCA-RP60KAQ PLA-RP71BA SEZ-KD71VAQ 6.0kW 7.1kW PCA-RP71HAQ PCA-RP71KAQ 10.0kW PLA-RP100BA PCA-RP100KAQ PLA-RP125BA PCA-RP125KAQ PLA-RP140BA PCA-RP140KAQ 12.5kW 14.0kW 17.0kW Remote controller Standard for SLZ-VAQ Standard for SLZ-VAL 10 Optional Standard for SEZ-VAQ OPTIONAL Standard Optional p.16 CEILING CONCEALED PEAD WALL MOUNTED p.14 PEA p.15 PKA OUTDOOR UNIT p.17 Outdoor Unit SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA SUZ-KA60VA PEAD-RP71JAA PKA-RP71KAL* SUZ-KA71VA PKA-RP100KAL PUHZ-RP100VKA PEAD-RP100JAA PEA-RP100GAA PEAD-RP125JAA PEA-RP125GAA PUHZ-RP125VKA PEAD-RP140JAA PEA-RP140GAA PUHZ-RP140VKA PEA-RP170WJA Optional Optional OPTIONAL OPTIONAL PUHZ-RP71VHA PUHZ-RP170VKA Optional Standard *PUHZ-RP71VHA only 11 Deluxe PLA Series Cassettes 4-Way Ceiling Cassette Advancements in Deluxe PLA Series Cassettes improve style and performance for ensured indoor comfort Wide Airflow Conventional model Deluxe PLA Series Cassettes utilise wide-angle outlets to distribute airflow to all corners of the room, ensuring the room is cooled/heated in an even and sufficient manner. Both horizontal airflow and fan speed have been reduced by 20% compared to conventional models, contributing to increased comfort for occupants. PLA-RP**BA With the ability to independently control each vane’s airflow pattern, Deluxe PLA Series Cassettes are perfect for both residential and office/commercial environments. Simply adjust airflow via the PAR-32MAA Wired Controller to suit the interior layout and seasonal conditions, ensuring even temperature distribution at all times. Settings can be changed anytime using a wired remote controller. Using wired remote controller, set airflow direction for each vane (manual setting also possible). Fixed Set by remote controller Vertical flow The Horizontal Airflow function prevents both cold draughts and/or heating airflow from striking occupants directly, thereby keeping people from becoming overchilled/over-heated. Auto Fan Speed Mode Independent Vane Direction Setting (P Series Outdoor only) Horizontal flow Less Cold Draught Wired remote controller (PAR-32MAA) has Independent Vane Direction Setting. This function is only available when indoor unit connects with PUHZ series. The fan speed on Deluxe PLA Series Cassettes is adjusted automatically, thereby maintaining a comfortable environment at all times. At the start of operation, a high fan speed achieves quick heating/cooling of the room. Once the desired temperature is reached, the fan speed is reduced for stable, more efficient heating/cooling and greater comfort. Fan speed setting by remote controller (four levels) Lo Mi1 Mi2 Hi Auto Special setting is required for wireless remote controller Quiet Operation An improved airflow path and powerful high-capacity flow fan contribute to quieter operation. Power flow fan “Pure White” Colour Wave Airflow Mode for Heating Advanced control of vanes, called Wave Airflow, provides even greater heat distribution by periodically moving vanes up and down to provide a consistent temperature throughout the room. Stylish, pure white coloured panels and wired remote controller present a clean, streamlined installation that is a suitable match for any interior. Wave control effect thermograph •Stylish indoor unit vane covers (when unit is turned off) Vertical flow Other Features •Maximum upward draining of 850mm Swing mode •Wireless remote controller option available •Duct flange for fresh-air intake •Branch duct Temperature gap with uneven temperature distribution Temperature gap is decreased, and room is warmed uniformly Automatic Grille Lowering Function (Optional) Easy to use/simple maintenance “Wave Airflow” operation image 1.2m An automatic grille lowering function capable of stopping at eight different heights is available to simplify filter maintenance. 1.6m 2.0m 2.4m Vertical flow Vertical flow Vertical flow Vertical flow Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner. 12 Packaged elevating (up-down) controller in the grille (PLP-6BAJ) can be used when outdoor unit is both PUHZ series and SUZ series. Wired remote controller (PAR32MAA) has automatic grille lowering function. This function is only available when indoor unit connects with PUHZ series. Elevating (up-down) controller 2.8m 3.2m 3.6m 4.0m Automatic elevation to four metres Deluxe PLA Series 4-way Cassettes can be equipped with the i-See Sensor, a radiation-based sensor that monitors floor-level temperatures throughout the room to ensure room comfort. The i-See Sensor works to ensure even temperature distribution and save energy (requires optional corner panel). i-See Sensor Operation The i-See Sensor rotates 90° every two minutes*, taking 5-second measurements at each position to accurately determine floor-level temperatures on all sides of the room. The i-See Sensor calculates the temperature by measuring the infrared rays emanating from the walls and floors, and measuring the floor-level temperature. 360° Floor-level temperature measured throughout the room. i-See Sensor improves energy efficiency and enhances room comfort. 90° rotation The i-See Sensor is an innovative Mitsubishi Electric technology that uses a radiation-based sensor to monitor the temperature throughout the entire room. When connected to the air conditioner control panel, the i-See Sensor works to maximise room comfort through 360° sensing that covers the whole floor space, giving a more accurate and even temperature reading. 90° rotation 5 sec measurement 5 sec measurement 90° rotation 5 sec measurement 5 sec measurement *The sensor rotates 360 degrees once every two minutes when there is significant temperature disparity and once every five minutes when a stable, even temperature has been reached. “I Feel” Temperature Control The sensory temperature is calculated by measuring the airintake temperature and the floor temperature. This technology makes it possible to avoid overcooling or overheating. Without i-See Sensor Indoor temperature Indoor temperature detecting sensor detecting sensor Only intake-air temperature at the ceiling is measured, resulting in uneven temperature distribution. With i-See Sensor Indoor temperature Indoor temperature detecting sensor detecting sensor Area Areawhich whichthe the “i-see i-see Sensor” Sensor checks checks 360° sensing Area which the sensor checks Both floor-level and intake-air temperatures are measured, providing operation that creates a comfortable room environment from ceiling to floor. 2.7m Heating Heating 11.5m Set temperature: 23°C Set temperature: 20°C with i-See Sensor + Auto Fan Speed without i-See Sensor Specifications: 4-way ceiling-cassette (PLA) Indoor unit PLA-RP60BA PLA-RP71BA PLA-RP71BA PLA-RP100BA PLA-RP125BA PLA-RP140BA Outdoor unit SUZ-KA60VAD SUZ-KA71VAD PUHZ-RP71VHA5 PUHZ-RP100VKA2 PUHZ-RP125VKA2 PUHZ-RP140VKA2 Function Capacity (min.-max.) (kW) Input (kW) Cooling Heating Cooling Heating Cooling 6.1 (1.1-6.3) 6.9 (0.9-8.0) 7.1 (0.9-8.1) 8.0 (0.9-10.2) 7.1 (3.3-8.1) Heating Cooling Heating Cooling Heating Cooling Heating 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) 1.78 1.97 2.07 2.19 2.09 2.17 2.50 2.95 3.80 3.71 3.97 4.43 Rated EER/COP 3.80 3.99 3.46 3.71 3.42 3.59 3.98 3.74 3.25 3.71 3.25 3.55 Rated AEER/ACOP 3.73 3.92 3.41 3.66 3.24 3.42 3.65 3.49 3.07 3.51 3.17 3.39 AEER/ACOP (part-load %) * 4.13 PLA-RP60BA Indoor unit PLA-RP71BA PLA-RP100BA PLA-RP125BA PLA-RP140BA V: Single-phase, 50Hz, 230V Power supply Airflow (Lo-Mi2-Mid-Hi) Sound pressure level Dimensions PLA-RP71BA 3.95 CMM 12-14-16-18 14-16-18-21 14-16-18-21 20-23-26-30 22-25-28-31 24-26-29-32 L/S 200-233-267-300 233-267-300-350 233-267-300-350 334-384-434-501 367-417-467-517 400-434-484-534 (dB) 28-29-31-32 28-30-32-34 28-30-32-34 32-34-37-40 34-36-39-41 36-39-42-44 Height (mm) Width (mm) Depth (mm) Weight (kg) Unit: 258, Panel: 35 Unit: 298, Panel: 35 Unit: 840, Panel: 950 Unit: 840, Panel: 950 Unit: 23, Panel: 6 Unit: 25, Panel: 6 Unit: 27, Panel: 6 *MEPS compliant at part load 13 ADVANCED OPTIONAL UPGRADE Available on PEAD PEAD Series Ceiling Concealed The thin, low-profile, ceiling-concealed indoor units of the PEAD Series are the perfect answer for air conditioning requirements of buildings with minimum ceiling installation space and wide-ranging external static pressure. Energysaving efficiency has been improved, thereby reducing electricity consumption and contributing to further reductions in operating cost. 250mm Compact Indoor Units Lighter Weight The height of the PEAD (7.1kW~14.0kW) models has Compared to the previous PEA-RP-EAQ (7.1kW~14.0kW) been unified to 250mm. Compared to the PEA-RP***GAA models, the unit weight has been reduced by an average of models, the height has been reduced by as much as 150mm, 27kg. This significant weight reduction has led to increased making installation possible in low ceilings with minimal ease of installation. clearance space. Wide Selection of Fan Speeds and External Static Pressure High Energy-Saving Efficiency All PEAD models incorporate five-stage external static pressure Compared to the previous PEA-RP-EAQ (7.1kW~14.0kW) conversions and three fan speed selections, offering the ultimate models, the PEAD-RP models achieve enhanced energy in comfort diversity. With a wide range of adjustable static savings through adopting a highly efficient DC fan motor. This pressures (35-125Pa), PEAD Series units are applicable to a contributes to an impressive reduction in electricity costs. wide range of building types and applications. Capacity Rated EER/COP 10.0kW 12.5kW 14.0kW PEA-RP PEAD-RP Zone Controller (Optional) Rated EER 3.24 3.90 20% UP The optional Zone Controller brings intuitive Rated COP 3.50 3.25 08% DOWN Rated EER 2.92 3.38 17% UP yet simple control to a whole new level, Rated COP 3.89 4.15 07% UP Rated EER 2.85 3.29 15% UP automatic unloading/ramping and energy Rated COP 3.74 4.08 09% UP saving sensor functions. Find out more with the ability to control up to 8 zones, about this controller on page 6. Specifications: Ceiling-concealed (PEAD) Indoor Unit Outdoor Unit PEAD-RP71JAA PEAD-RP100JAA PEAD-RP125JAA PEAD-RP140JAA SUZ-KA71VAD PUHZ-RP100VKA2 PUHZ-RP125VKA2 PUHZ-RP140VKA2 Function (kW) Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min.-max.) (kW) 7.1 (0.9-8.1) 8.0 (0.9-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) Input 2.10 2.04 2.77 2.72 3.60 3.50 3.91 4.04 Rated EER/COP 3.38 4.14 3.90 4.53 3.38 4.15 3.29 4.08 Rated AEER/ACOP 3.33 4.08 3.60 4.17 3.18 3.90 3.12 3.86 PEAD-RP71JAA Indoor Unit PEAD-RP100JAA PEAD-RP140JAA CMM 17.5-21-25 24-29-34 29.5-35.5-42 32-39-46 L/S 292-350-417 400-483-567 492-592-700 533-650-767 Sound Pressure Level (dB) 30-34-39 33-38-42 36-40-44 40-44-49 Return Air Spigot Size (mm) 1,058×210 1,358×210 1,358×210 1,558×210 (mm) 1,060×178 1,360×178 1,360×178 1,560×178 Airflow 35/50/70/100/125 External Static Pressure Pa Supply Air Spigot Size Dimensions Weight Energy Star ® 14 PEAD-RP125JAA V: Single-phase, 50Hz, 230V Power Supply Height (mm) Width (mm) Depth (mm) (kg) 250 1,400 1,100 1,600 732 29 38 39 43 ADVANCED OPTIONAL UPGRADE Available on PEA PEA Series Ceiling Concealed The PEA Series high static airflow allows air to be directed to different areas of your home or office with ease, ideal for heating or cooling a number of rooms at once. PEA-RP100~140GAA Flexible Duct Design Enables Use of High-Pressure Static Fan 400mm With a maximum 150Pa external static high-pressure setting, PEA Series models offer complete flexibility in duct design. The increased variation in airflow options ensures operation Versatile and Easy Installation Options that best matches virtually all room layouts. PEA Series models offer both versatility and ease of installation/application; for example, it is possible to adjust the distance between the air-intake and air-outlet vents to create the optimal airflow configuration. Long rectangular room Room with fixed ceiling fixtures Zone Controller (Optional) The optional Zone Controller brings intuitive yet simple control to a whole new level, with the ability to control up to 8 zones, automatic unloading/ramping and energy saving sensor functions. Find out more L-shaped room about this controller on page 6. Specifications: Ceiling-concealed (PEA) Indoor unit Outdoor unit PEA-RP100GAA PEA-RP125GAA PEA-RP140GAA PEA-RP170WJA PUHZ-RP100VKA2 PUHZ-RP125VKA2 PUHZ-RP140VKA2 PUHZ-RP170VKA2 Cooling Function Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min.-max.) (kW) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.5 (6.2-15.3) 16.0 (5.7-18.0) 16.0 (9.0-20.0) 20.0 (9.5-22.4) Input (kW) 3.05 3.16 3.97 3.27 4.19 3.90 5.00 6.00 Rated EER/COP *1 3.96 4.47 3.27 4.29 3.23 4.14 3.64 3.84 Rated AEER/ACOP 3.65 4.12 3.10 4.04 3.07 3.93 3.47 3.69 Indoor unit PEA-RP100GAA Power supply PEA-RP125GAA PEA-RP140GAA PEA-RP170WJA CMM 34-42 (Lo-Hi) 48-60 (Lo-Hi) 50-72 (Lo-Hi) L/S 560-700 (Lo-Hi) 800-1000 (Lo-Hi) 833-1,200 (Lo-Hi) External static pressure Pa 60/75/100/150 50/100/150 Sound pressure level *2 (dB) Height (mm) 400 470 Width (mm) 1,400 1,370 Depth (mm) 634 1,120 (kg) 63 108 Weight 470mm Single-phase, 50Hz, 230V Airflow Dimensions PEA-RP170WJA 42-45 39-42 38-41-44 Energy Star ® *1 Rated EER/COP for PEA-RP170WJA are measured at ESP 75 Pa *2 Sound pressure level for PEA-RP170WJA are measured in anechoic chamber at ESP 150 Pa 15 PCA Series Ceiling Suspended PCA Series high performance units are designed for style and efficiency. A stylish indoor unit design and airflow settings for both high and low-ceiling interiors expand installation possibilities. With four speed settings and auto air-speed adjustment, PCA Series units provide energy efficient comfort no matter what the season. PCA-RP50-140KAQ 230mm Stylish Indoor Unit Design A stylish square-like design is adopted for the indoor units of Fresh Outside-Air Intake all PCA Series models. As a result, the units blend in better Units are equipped with a knock-out with the ceiling. hole that enables the induction of fresh outside-air. Optional Drain Pump The pumping height of the optional Equipped with High/Low-Ceiling Modes drain pump has been increased All PCA Series units are equipped with high and low-ceiling from 400mm to 600mm, expanding operation modes, that make it possible to switch the airflow flexibility in choosing unit location volume to match room height. The ability to choose the during installation work. optimum airflow volume makes it possible to optimise the breezy sensation felt throughout the room. Equipped with Automatic Air-Speed Adjustment In addition to the conventional 4-speed setting, units are now Capacity High ceiling Standard ceiling Low ceiling equipped with an automatic air-speed adjustment mode. This PCA-RP50 3.5m 2.7m 2.5m setting automatically adjusts the air-speed to conditions that PCA-RP60 3.5m 2.7m 2.5m 2.5m PCA-RP71 3.5m 2.7m operation, the airflow is set to high-speed to quickly heat/cool PCA-RP100 4.2m 3.0m 2.6m PCA-RP125 4.2m 3.0m 2.6m the room. When the room temperature reaches the desired PCA-RP140 4.2m 3.0m 2.6m match the room environment. At the start of heating/cooling setting, the airflow speed is decreased PCA-RP71HAQ Gentle Strong automatically for comfortable heating/ After room temperature is stabilised Start of cooling/heating cooling operation. 280mm Specifications: Ceiling-suspended (PCA) Indoor unit PCA-RP50KAQ PCA-RP60KAQ PCA-RP71KAQ PCA-RP71KAQ PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ PCA-RP71HAQ Outdoor unit SUZ-KA50VAD SUZ-KA60VAD SUZ-KA71VAD PUHZ-RP71VHA5 PUHZ-RP100VKA2 PUHZ-RP125VKA2 PUHZ-RP140VKA2 PUHZ-RP71VHA5 Cooling Function Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min.-max.) (kW) 4.9 (1.1-5.6) 5.5 (0.9-6.6) 5.7 (1.1-6.3) 6.9 (0.9-8.0) 7.1 (0.9-8.1) 7.9 (0.9-10.2) 7.1 (3.3-8.1) 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) 7.1 (3.3-8.1) 7.6 (3.5-10.2) Input (kW) 1.49 1.68 1.77 2.02 2.06 1.96 2.21 2.23 2.63 3.02 4.05 3.88 3.97 4.43 2.21 2.23 Rated EER/COP 3.48 3.49 3.84 3.87 3.51 3.99 3.66 3.58 3.79 3.73 3.28 3.58 3.24 3.51 3.13 3.44 Rated AEER/ACOP 3.41 3.44 3.76 3.81 3.46 3.93 3.45 3.41 3.49 3.48 3.09 3.39 3.07 3.35 2.98 3.27 AEER/ACOP (part-load %) * 4.19 PCA-RP50KAQ Indoor unit PCA-RP60KAQ PCA-RP71KAQ Airflow (Lo-Mi2-Mid-Hi) Sound pressure level Weight PCA-RP100KAQ PCA-RP125KAQ PCA-RP140KAQ PCA-RP71HAQ Single-phase, 50Hz, 230V V: Single-phase, 50Hz, 230V Power supply Dimensions PCA-RP71KAQ 3.91 CMM 10-11-13-15 15-16-17-19 16-17-18-20 22-24-26-28 23-25-27-29 24-26-29-32 17-19 L/S 167-183-217-250 250-267-283-317 267-283-300-333 367-400-433-467 383-417-450-483 400-433-483-533 283-317 (dB) 32-34-37-40 33-35-37-40 35-37-39-41 37-39-41-43 39-41-43-45 41-43-45-48 34-38 Height (mm) Width (mm) Depth (mm) (kg) 280 230 960 1,280 25 32 1,136 1,600 650 680 36 38 39 41 * MEPS compliant at part load 16 PKA Series Wall Mounted The large capacity PKA Series is both elegant and compact. With greater placement options and high airflow, PKA Series units are ideal light commercial uses (i.e. offices, stores, and server rooms). Removable Intake Grille Filter Allowing Easy Cleaning Filter slides out and can be washed in water. Suitable for Server Room Applications The PKA Series provides an economical split system solution for high sensible applications due to their larger coil size. As a result they are ideal for applications such as server rooms and laboratories where there is a need for sensible cooling. Wired Remote Controller Available (Optional) A separately sold wired remote controller and terminal block are available to suit various installation sites. When connecting a wired remote controller the MAC-333IF-E interface is not required. Auto-Vane Shutter The vane closes automatically when the unit is not running, creating a sleek flat finish that is aesthetically pleasing. Specifications: Wall-mounted (PKA) Indoor unit Outdoor unit Function Capacity (min.-max.) (kW) Input (kW) PKA-RP71KAL PKA-RP100KAL PUHZ-RP71VHA5 PUHZ-RP100VKA2 Cooling Heating 7.1 (3.3-8.1) 8.0 (3.5-10.2) Cooling Heating 10.0 (4.9-11.4) 11.2 (4.5-14.0) 1.96 2.13 2.90 3.10 Rated EER/COP 3.62 3.79 3.60 3.50 Rated AEER/ACOP 3.42 3.59 3.33 3.28 V: Single-phase, 50Hz, 230V Power supply Airflow (Lo-Mid-Hi) Sound pressure level Dimensions Weight PKA-RP100KAL PKA-RP71KAL Indoor unit CMM 18-20-22 20-23-26 L/S 300-333-367 333-383-433 (dB) 39-42-45 41-45-49 Height (mm) 365 Width (mm) 1,170 Depth (mm) 295 (kg) 21 17 ADVANCED OPTIONAL UPGRADE Available on SEZ SLZ /SEZ Series 4-Way Cassette and Compact Ceiling-concealed Compact, quiet concealed indoor units equipped with cutting-edge control for enhanced comfort. Compact Designs Energy-Saving Operation There are models with capacity ranges for any room size. SLZ Series Boasting low electricity consumption, lightweight units sit in your ceiling space with only the grille visible, providing SLZ/SEZ series air conditioners are the discrete comfort. Meanwhile SEZ Series units are a slim 200mm in height, key to fresh, cost-effective comfort. making them ideal for tight installation spaces. SLZ-KA25/50 Air Cleaning Filter This built-in filter removes dust and SEZ-KD35/50/60/71 990mm other particles, keeping the air clean at all times. Maintenance is as simple as 700mm vacuuming. The long-life filter in SLZ/ 208mm SEZ Series indoor units can be used 200mm for approximately 2,500 hours before 650mm requiring replacement. 650mm Fresh-Air Intake (SLZ Series) A duct hole is provided in the main Impressively Quiet body, making it possible to intake fresh S Series units offer quiet operation at a hushed noise level of 23dBA air from outside. (SEZ-KD35), ensuring a calm and comfortable environment. They’re so quiet that you’ll find yourself checking to see if they’re on. Noise Level Comparison Rustling leaves Breathing 0dBA Library interior 20dBA Average street traffic Dishwasher 40dBA 60dBA Subway car interior 80dBA 23dBA - Quiet! Specifications: 4-way cassette / Compact ceiling-concealed (SLZ, SEZ) Indoor unit SLZ-KA25VAQ SLZ-KA50VAQ SEZ-KD35VAQ SEZ-KD50VAQ SEZ-KD60VAQ SEZ-KD71VAQ Outdoor unit SUZ-KA25VA3 SUZ-KA50VAD SUZ-KA35VAD SUZ-KA50VAD SUZ-KA60VAD SUZ-KA71VAD Cooling Function Cooling Heating Heating Cooling Heating Cooling Heating Cooling Heating Cooling Heating Capacity (min.-max.) (kW ) 2.3 (0.9-3.2) 3.1 (0.9-4.5) 4.2 (1.1-5.2) 4.5 (0.9-6.5) 3.7 (1.0-3.9) 4.2 (0.9-5.0) 5.1 (1.1-5.6) 6.4 (1.1-7.2) 5.6 (1.1-6.3) 7.4 (0.9-8.0) 6.5 (0.9-8.3) 8.1 (0.9-10.4) Input (kW ) 0.6 0.82 1.27 1.37 1.09 1.13 1.64 1.81 1.77 2.05 2.06 2.18 Rated EER/COP 3.81 3.94 3.35 3.31 3.39 3.72 3.17 3.54 3.28 3.55 3.28 3.69 Rated AEER/ACOP 3.64 3.81 3.28 3.25 3.31 3.63 3.11 3.49 3.22 3.50 3.23 3.64 AEER/ACOP (part-load %) * 4.32 3.72 SLZ-KA25VAQ Indoor unit SLZ-KA50VAQ SEZ-KD35VAQ SEZ-KD50VAQ SEZ-KD60VAQ SEZ-KD71VAQ V: Single-phase, 50Hz, 230V Power supply CMM 8-9-10 8-9-11 7-9-11 10-12.5-15 12-15-18 12-16-20 L/S 133-150-167 133-150-183 117-150-183 167-208-250 200-250-300 200-267-333 Sound pressure level (dB) 28-31-37 30-34-39 23-28-33 Supply air spigot size (mm) Height (mm) Unit: 235, Panel: 20 200 200 Width (mm) Unit: 570, Panel: 650 990 1,190 Depth (mm) Unit: 570, Panel: 650 (kg) Unit: 17, Panel: 3 Airflow (Lo-Mid-Hi) External static pressure Pa Dimensions Weight 5/15/35/50 — 30-34-37 860×150 — 30-35-40 1,060×150 700 21 30-34-38 700 23 27 * MEPS compliant at part load 18 Main Features of Mr. Slim Inverter Units Indoor unit SLZ-VAQ SLZ-VAL SEZ-VA PLA PEAD PEA PKA PCA-KA Combination Outdoor unit Energy Saving Air Quality Air Distribution SUZ SUZ SUZ PUHZ SUZ PUHZ SUZ PUHZ PUHZ PUHZ SUZ Felt Temperature Control (i-See Sensor) – – – Opt Opt – – – – – – Fresh-Air Intake • • – • • – – – – • • High-Efficiency Filter – – – Opt Opt – – – – Opt Opt Oil Mist Filter – – – – – – – – – – – Long-Life Filter • • – • • • • – – • • Filter Check Signal • – – • • • • – Opt • • Auto Vane • • – • • – – – • • • Horizontal Vane (Auto Swing) • • – • • – – – • • • High Ceiling Mode – – – • • – – – – • • Auto Fan Speed Mode – – • • • – – – • • • On/Off Operation Timer • • • • • • • • • • • Auto Change Over *1 • • • • • • • • • • • Auto Restart • • • • • • • • • • • Low-Temperature Cooling • • • • • • • • • • • Low-Noise Operation (Outdoor Unit) – – – • – • – • • • – Rotation, Back-up and 2nd Stage Cut-in Function – – – • – • – – Opt • – Opt • Opt Opt Opt Opt Opt Opt Opt Opt Opt Wi-Fi Control – – Opt – – Opt Opt Opt – – – PAR-32MAA Control *2 • Opt • Opt Opt Opt Opt Opt Opt • • Centralised On/Off Control *2 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt System Group Control *2 Opt Opt Opt • Opt • Opt • Opt • Opt M-NET Connection *2 Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Opt Reuse of Existing Wiring – – – Opt – Opt – – Opt Opt – Drain Pump • • Opt • • – – – – Opt Opt Pump Down Switch – – – • – • – • • • – Flare Connection • • • • • • • •*3 • • • Self-Diagnosis Function (Check Code Display) • • • • • • • • • • • Failure Recall Function • • • • • • • • • • • Convenience Wireless Controller System Control Installation Maintenance *1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible *2 Please refer “System Control” on page 20 for details *3 Not available with PEA-RP170WJA models 19 System Controls MAJOR SYSTEM CONTROL System Examples Indoor Unit S Series & P Series Indoor Unit P Series Indoor Unit S Series Outdoor P Series Outdoor Outdoor Unit A Details PAR-32MAA Control Standard equipment SLZ-VAQ, SEZ-VAQ, PCA-KAQ PAR-32 can be hardwired to MA Terminal Block (compatible models) to allow MAC-559IF-E connection via CN105. Wi-Fi Control ADVANCED MAC-559IF-E PAR-32MAA (Example of 1 : 1 system) MAC-559IF-E PAR-32MAA (Example of Simultaneous Twin) OPTIONAL UPGRADE C System Group Control MAC-397IF-E MAC-333IF-E PAR-32MAA PAR-32MAA D M-NET Connections Outdoor unit Outdoor unit Indoor unit Indoor unit Indoor unit City Multi indoor unit PAR-32MAA Indoor unit PAR-32MAA MELANS system controller (AE-200A etc) MELANS system controller (AE-200A etc) • PAR-32MAA • MAC-559IF-E Twin pack connection: 1 x PAR-32 + 1 x MAC-559IF-E connected to master indoor unit, secondary indoor follows suit. • One remote controller can control multiple air conditioners with the same settings simultaneously • One remote controller can control up to 16 refrigerant systems • Up to two remote controllers can be connected <S Series Outdoor Unit> • MAC-397IF-E/MAC-333IF-E (Interface) • PAR-32MAA (Wired remote controller) • Group of air conditioners can be controlled by MELANS system controller (M-NET) <S Series Outdoor Unit> • MAC-399IF-E/MAC-333IF-E • MELANS System controller <P Series Outdoor Unit> • PAR-32MAA (Wired remote controller) <P Series Outdoor Unit> • PAC-SF83MA-E (M-NET converter) • MELANS System controller PAR-32MAA PAR-32MAA MAC-399IF-E MAC-333IF-E • PAR-32MAA (Wired remote controller) Optional equipment SLZ-VAL, PLA, PEAD, PEA, PKA PAR-32MAA B Major Optional Parts Required M-NET adapter PAC-SF83MA-E FOR P SERIES AND S SERIES INDOOR UNITS System Examples Wired remote controller A Wireless remote controller 2-remote Controller Control • Up to two remote controllers can be connected to one group With two remote controllers, control can be performed locally and remotely from two locations. PAR-SL97A-E PAR-32MAA PAR-32MAA * Set "Main" and "Sub" remote controllers. (Example of 1 : 1 system) B Remote control panel Wired remote controller Operation Control by Pulse Signal Remote Display of Operating Status Adapter for remote On/Off Remote control panel Wired remote controller Remote operation adapter/ Connector cable for remote display + Relay box PAR-32 MAA (Example of 1 : 1 system) E Timer Operation Allows On/Off operation with timer *For control by an external timer, refer to B Operation Control by Level Signal. 20 PAR-32MAA (Example of 1 : 1 system) • Operation other than On/Off (e.g. adjustment of temperature, fan speed, and airflow) can be performed even when remote controller operation is prohibited • Timer control is possible with an external timer • Adapter for remote On/Off PAC-SE55RA-E • Relay box (to be purchased locally) • Remote control panel (to be purchased locally) • The pulse signal can be turned On/Off • Operation/emergency signal can be received at a remote location • Connector cable for remote display PAC-SA88HA-E / PAC-725AD (10 pcs. x PAC-SA88HA-E) • Relay box (to be purchased locally) • Remote control panel (to be purchased locally) • Operation/emergency signal can be received at a remote location (when channelled through the PAC-SF40RM-E no-voltage signal, when channelled through the PAC-SA88HA-E DC 12V signal) • Remote display panel (to be purchased locally) • Connector cable for remote display PAC-SA88HA-E / PAC-725AD • Relay box (to be purchased locally) • Remote operation adapter PAC-SF40RM-E PAR-SL97A-E Relay box (to be purchased locally) Connector cable for remote display Remote control panel PAR-SL97A-E (Example of 1 : 1 system x 2) Remote operation adapter/ Connector cable for remote display + Relay box Operating status can be displayed at a remote location. Remote display panel • Wired Remote Controller PAR-32MAA (for PKA, PAC-SH29TC-E is required) • Wireless Remote Controller PAR-SL97A-E (for SEZ and PEAD) • Wireless Remote Controller Kit for PCA PAR-SL94B-E (Example of 1 : 1 system x 2) Connector cable for remote display (Example of 1 : 1 system x 2) D Relay box (to be purchased locally) Relay box (to be purchased locally) Remote control panel • Both wired and wireless remote controllers can be used in combination Major Optional Parts Required (Example of Simultaneous Twin) Adapter for remote On/Off (Example of 1 : 1 system x 2) C * When using wired and wireless remote controllers Relay box (to be purchased locally) Operation Control by Level Signal Air conditioner can be started/ stopped remotely. In addition, On/Off operation by local remote controller can be prohibited/permitted. Details Remote display panel *Unable to use with wireless remote controller PAR-SL97A-E (Example of Simultaneous Twin) • Weekly Timer: On/Off and up to 8 pattern temperatures can be set for each calendar day (Initial setting) • On/Off Timer: On/Off can be set once each within 72 hr in intervals of 5 minute units • Auto-off Timer: Operation will be switched off after a certain amount of time has elapsed. Set time can be changed from 30 min. to 4 hr. at 10 min. intervals *Simple Timer and Auto-off Timer cannot be used at the same time Standard functions of PAR-32MAA Specifications Specification: Outdoor Unit Outdoor unit SUZ-KA25VA SUZ-KA35VA SUZ-KA50VA External finish Munsell 3.0Y 7.8/1.1 Power supply Single-phase, 50Hz, 230V (kW) 0.65 0.9 0.9 1.2 34 (572)/32 (538) 33 (557) 49 (817) 51 (850)/49 (816) 50 (835)/48 (800) Cooling mode 46 47 53 55 Heating mode 46 48 55 55 59 61 68 69 Airflow (cooling/heating) CMM (L /S) (dB) Sound power level Dimensions SUZ-KA71VA 0.55 Compressor output Sound pressure level (dB) SUZ-KA60VA Height (mm) 550 850 880 Width (mm) 800 840 840 Depth (mm) 285 330 330 Weight (kg) Chargeless piping length (m) Max. piping length (m) 20 30 Breaker size (A) 10 20 30 33 50 53 53 7 *Above specifications are for outdoor units only Outdoor unit PUHZ-RP71VHA PUHZ-RP100VKA PUHZ-RP125VKA External finish Munsell 3.0Y 7.8/1.1 Power supply V: Single-phase, 50Hz, 230V (kW) Compressor output PUHZ-RP140VKA PUHZ-RP170VKA 2.9 3.0 1.6 1.9 55 (916) 110 (1,833) Cooling mode 47 49 50 50 58 Silent mode 44 46 47 47 56 Heating mode 48 51 52 52 59 (dB) 66 69 70 70 76 Height (mm) 943 1,338 Width (mm) 950 1,050 Depth (mm) 330 330 Weight (kg) 67 120 127 Chargeless piping length (m) 30 30 Max. piping length (m) 50 75 17.17/19.23 19.40/23.90 Airflow (cooling/heating) Sound pressure level (dB) Sound power level Dimensions CMM (L /S) 2.4 120 (2,000) 118 Protection device 140 (2,330) Discharge thermo, HP switch Rated running current (cooling/heating) (A) 9.05/9.64 Breaker size (A) 25 12.64/13.58 16.36/16.90 32 40 *Above specifications are for outdoor units only 21 Specifications Note for All Specifications Rating conditions (AS/NZS 3823) Total input based on the indicated voltage (indoor/outdoor) Rating conditions (AS/NZS 3823) Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB Cooling - Outdoor: 35°C (95°F) DB Heating - Indoor: 20°C (68°F) DB Heating - Outdoor: 7°C (45°F) DB, 6°C (43°F) WB 50Hz Refrigerant piping length (one-way): 5m (16ft.) Indoor Indoor 50Hz Single-phase, 230V Single-phase, 230V SUZ-KA SUZ-KA 25/35 Upper limit (DB) Upper limit (DB) Cooling Lower limit (DB) Heating Upper limit (DB) Heating Single-phase, 230V Single-phase, 230V Guaranteed Operating Range Cooling Outdoor Outdoor Lower limit (DB) Upper limit (DB) Lower limit (DB) Lower limit (DB) 25/35 46°C –10°C 24°C 50/60/71 50/60/71 46°C PUHZ 43°C –10°C –15°C 24°C 24°C –10°C –10°C PUHZ 71/100/125/140/170 71/100/125/140/170 43°C –15°C 24°C –10°C –10°C 46°C 46°C –5°C (–15°C ) –5°C (–15°C ) 21°C 21°C –20°C –20°C *With the optional air protection guide, the operation at –15°C outdoor temperature is possible. Sound Pressure Level •Sound pressure measurements were conducted in an anechoic chamber •The actual noise level depends on the distance from the unit and the acoustic environment Amount of Necessary Refrigerant Amount of Necessary Refrigerant (R410A: kg) Factory charged Additional charged Calculation Piping length 7m 10m 15m 20m 25m 30m SUZ-KA25 0.8 0.15 0.3 0.45 — — SUZ-KA35 1.05 0.15 0.3 0.45 — — SUZ-KA50 1.6 0.06 0.16 0.26 0.36 0.46 SUZ-KA60 1.8 0.06 0.16 0.26 0.36 0.46 SUZ-KA71 1.8 0.165 0.44 0.715 0.99 1.265 Xg = 30g/m × (length-5) m Xg = 20g/m × (length-7) m Factory charged Xg = 55g/m × (length-7) m Additional charged Piping length 10 - 30m 31 - 40m 41 - 50m 51 - 60m 61 - 75m PUHZ-RP71 3.5 0.6 1.2 — — PUHZ-RP100/125/140 5.5 0.6 1.2 1.8 2.4 61 - 75m Factory charged Additional charged Piping length PUHZ-RP170 22 10 - 30m 31 - 40m 41 - 50m 51 - 60m 7.7 0.9 1.8 2.7 3.6 Optional Parts Optional Parts Part name Air discharge guide Air outlet shutter plate Air protection guide Control/service tool Centralised drain pan Drain pump Model name Application name PAC-SG59SG-E PUHZ-RP71 PAC-SH96SG-E PUHZ-RP100/125/140 PAC-SH51SP-E PLA-RP PAC-SH63AG-E PUHZ-RP71 PAC-SH95AG-E PUHZ-RP100/125/140 PAC-SK52ST PLA-RP PEAD-RP71 PAC-KE94TB-E PEAD-RP100/125 PAC-KE95TB-E PEAD-RP140 i-See Sensor corner panel PAC-SA1ME-E PLA-RP PUHZ-RP71/100/125/140 Shutter plate PAC-SH51SP-E PLA-RP PAC-SG64DP-E PUHZ-RP71 Joint pipe PAC-SH97DP-E PUHZ-RP100/125/140 PAC-SG73RJ-E PAC-SG75RJ-E PUHZ-RP71/100/125/140 PUHZ-RP71/100/125/140 PAC-SH83DM-E PCA-RP50KAQ M-NET converter PAC-SF83MA-E PUHZ-RP71/100/125/140 Multi-function casement PAC-SH53TM-E PLA-RP PAC-SG94HR-E PKA-RP PAC-SG96HR-E PCA-RP50/60/71/100/125/140KAQ PAC-SG97HR-E PEAD-RP PAC-SH84DM-E High efficiency filter element Filter box PCA-RP71/100/125/140KAQ SEZ-KD Power supply terminal kit PAC-SG61DS-E PUHZ-RP71/100/125/140 Flange for fresh-air intake PAC-SH65OF-E PLA-RP PAC-SH52HR-E PLA-RP Remote On/Off adaptor PAC-SE55RA-E All indoor units Remote operation adaptor PAC-SF40RM-E All indoor units*2 (excluding PKA-RP) Remote sensor PAC-SE41TS-E All indoor units Space panel PAC-SH48AS-E PLA-RP SLZ-KA, SEZ-KD, PLA-RP60/71*1 PEAD-RP71*1, PCA-RP50/60/71*1 Terminal block PAC-SH29TC-E PKA-RP for wired remote controller Connector cable for remote display PAC-SA88HA-E All indoor units Wired remote controller PAR-32MAA All indoor units (excluding SLZ-VAL) PLA-RP60/71*1 MAC-397IF-E SLZ-KA, SEZ-KD, PEAD-RP71*1, PCA-RP50/60/71*1 MAC-399IF-E SLZ-KA, SEZ-KD, PLA-RP60/71*1 PEAD-RP71*1, PCA-RP50/60/71*1 MAC-333IF-E 9.52 12.7 15.88 19.05 PCA-RP60KAQ Drain socket M-NET &Terminal interface Application name PAC-KE93TB-E PAC-KE07DM-E M-NET interface Model name PAC-SH59KF-E PAC-SH85DM-E MA & Contact terminal interface Part name Wireless remote controller PAR-FL32MA-E PEAD-RP Wireless remote controller signal sender PAR-SL97A-E SEZ-KD, PLA-RP PAR-SA9CA-E SEZ-KD, PEAD-RP PAR-SA9FA-E PLA-RP Wireless remote controller kit (Sender & Receiver) PAR-SL94B-E PCA-RP PAC-SH88KF-E PCA-RP50KAQ Power supply unit PAC-SC51KUA All outdoor units PAC-SH89KF-E PCA-RP60/71KAQ All indoor units PCA-RP100/125/140KAQ Multiple remote controller adaptor PAC-725AD PAC-SH90KF-E Wi-Fi Adaptor MAC-559IF-E All PEA/PEAD/SEZ indoor units Wireless remote controller signal receiver High efficiency filter *1 P series indoor units can be used in combination with SUZ outdoor units *2 Unable to use with wireless remote controller Refrigerant Piping Capacity SUZ-KA25 SUZ-KA35 SUZ-KA50 SUZ-KA60 SUZ-KA71 PUHZ-RP71 PUHZ-RP100/125/140 PUHZ-RP170 Between indoor & outdoor units Max. height difference (m) Max. piping length (m) 12 20 12 30 30 30 30 30 30 20 30 30 30 50 75 75 Pipe size OD (mm) Thickness (mm) Liquid: ø6.35 t 0.8 Gas: ø9.52 t 0.8 Liquid: ø6.35 t 0.8 Gas: ø9.52 t 0.8 Liquid: ø6.35 t 0.8 Gas: ø12.7 t 0.8 Liquid: ø6.35 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: ø15.88 t 1.0 Liquid: ø9.52 t 0.8 Gas: t 1.0 ø25.4 23 NOTICE •Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils. •Before attempting any installation work you must read the installation instructions. •New tools, materials and procedures are required to install these products. •By law, only persons suitably licensed are permitted to install and service air conditioning units. •Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before installation of these products. •Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines. •Do not install indoor units in areas where the emission of VOCs such as phthalate compounds and formaldehyde is known to be high (e.g. mobile phone base stations) as this may result in a chemical reaction. •When installing, relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the refrigerant lines. •Do not mix it with any other refrigerant and do not allow air to remain in the lines. •If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and may result in an explosion and other hazards. •The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety. For more information on Mitsubishi Electric Heat Pumps, please call our customer service team on 0800 784 382 www.mitsubishi-electric.co.nz Black Diamond Technologies Exclusive distributor of Mitsubishi Electric products in New Zealand. WELLINGTON AUCKLAND CHRISTCHURCH HEAD OFFICE BRANCH BRANCH 1 Parliament Street Unit 1, 4 Walls Road 44 Halwyn Drive PO Box 30772 PO Box 12726 PO Box 16904 Lower Hutt 5040 Penrose, Auckland 1642 Hornby, Christchurch 8441 Phone (04) 560 9147 Phone (09) 526 9347 Phone (03) 341 2837 Fax (04) 560 9133 Fax (09) 526 9369 Fax (03) 341 2838 Be sure to ask for Mitsubishi Electric. Other brands share the 3-diamond logo, however are separate to the Mitsubishi Electric brand and cannot supply the models, features or guarantees outlined in this brochure. | All models, features and specifications are subject to change and amendment at anytime. May 2017 24
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement