null  User manual
Commercial Air Conditioning Systems
Quietly Superior Heat Pumps
1
Functionality, versatility and
comfort for every environment
Who is Mr. Slim?
Mr. Slim acquires its name for its slender, install-anywhere design. Developed
over 40 years ago in Japan to fit the unique living circumstances of limited
space, dense population and expensive energy costs, it is now adopted the
world over for its space saving, quiet and energy-efficient design that is built
to last.
A wide variety of indoor unit designs and outdoor unit capacities ensures
the flexibility to meet the most challenging of heating and cooling needs
for domestic and commercial applications. The Mitsubishi Electric Mr. Slim
Series of small to medium-sized split-type room air conditioners offers the
convenience of being compact yet powerful; a combination ensuring excellent
performance and easy installation. Available in a variety of capacity and
design combinations, the Mr. Slim Series is ideal for creating a best match
system for all of your heating and cooling requirements. Inverter-based units
provide industry-leading quiet operation and high efficiencies, ensuring
comfortable working and living environments.
2
Designed for Efficiency
Mitsubishi Electric’s Power Inverter Systems
Drastically Reduce Power Consumption
Silent Control
To better meet the needs of shops and offices, our outdoor
when the outdoor temperature drops, resulting in quiet, low-
units offer many energy saving features. Select the model to
noise operation. Operating noise is reduced by 3dBA.
Fan speed during cooling operation is automatically reduced
best match your needs from our expanded model range.
“Silent Control”
reduces sound further
Model RP140 (cooling)
Day
50dBA
Night
47dBA
3dBA
REDUCTION
Outdoor temperature: 35°C
Outdoor temperature: 25°C
R22
R410A
Inverter units (PUHZ-RP)
Non-inverter units
71 class
100 class
125 class
140 class
PUHZ-RP100/125/140/170
PUHZ-RP71
52
55
55
56
Normal
dBA
dBA
dBA
dBA
47
49
50
50
Low-noise Mode
dBA
dBA
dBA
dBA
44
46
47
47
dBA
dBA
dBA
dBA
Longer Maximum Piping Length
Side-flow Outdoor Units
As a result of increasing the volume of refrigerant, piping
Outdoor units with operating capacities of up to 20kW have
length has been increased to a maximum of 75m, expanding
been unified to a side-flow configuration, providing greater
the range of layout possibilities for unit installation.
versatility in installation locations. The compact footprint
Max. Piping Length
of these outdoor units also allows them to be used for
Max. Height Difference
Max. Piping Length
RP71
30m
50m
RP100/125/140/170
30m
75m
applications requiring large capacity heating and cooling.
High Power
More Power for Faster Heating/Cooling
Wider Performance Range
The maximum operating heating/cooling capacities of the
Operation is now possible at lower speeds, thus cutting
Mr. Slim Power Inverter units have been improved (compared
energy losses produced by the repeated On/Off operation
to conventional non-inverter models) when operating in either
of non-inverter models. Comfort is improved while power
low or high outdoor temperatures.
consumption is reduced.
Heating capacity (kW) 4-way ceiling cassette
R22 Non-inverter
Heating capacity ranges
R410A Power Inverter max. (PUHZ-RP)
71 class
8.4
10.2
121%
100 class
10.4
14.0
135%
125 class
14.0
16.0
114%
140 class
16.1
18.0
112%
71 class 3.5-10.2 kW
100 class 4.5-14.0 kW
125 class 5.0-16.0 kW
140 class 5.7-18.0 kW
0
2
Cooling capacity (kW) 4-way ceiling cassette
R22 Non-inverter
4
6
8
10
Cooling capacity ranges
R410A Power Inverter max. (PUHZ-RP)
71 class
7.7
8.1
105%
100 class
9.7
11.4
118%
125 class
12.4
14.0
113%
140 class
14.0
15.3
109%
4-way ceiling cassette
12
14
16
18kW
16
18kW
4-way ceiling cassette
71 class 3.3-8.1 kW
100 class 4.9-11.4 kW
125 class 5.5-14.0 kW
140 class 6.2-15.3 kW
0
2
4
6
8
10
12
14
3
Advanced Energy-saving Technologies
Highly Efficient Fan and Grille for Outdoor Unit
Highly Efficient Heat Exchanger
Both the shape of the fan and grille in Mr. Slim Series
Increasing both the density and surface area of Mr. Slim Series
outdoor units have been redesigned, helping increase airflow
heat exchangers has led to an improvement in overall heat-
capacity and create a more efficient heat exchange, all while
exchange efficiency.
maintaining the same operating noise level.
Outdoor Unit Fan Opening Increased (PUHZ-RP100~170)
High-density Heat Exchanger (PUHZ-RP100~170)
A reduction in pipe diameter from 9.52 to 7.94mm increases
The diameter of the outdoor unit fan opening has been
heat exchanger density. As a result greater heat exchange is
increased from 490 to 550mm. As a result, airflow
realised.
capacity has been increased while maintaining the same
fan rotation speed.
2 lines,
52 columns
2 lines,
64 columns
(RP100~140)
Opening increased
from 490 to 550mm
in diameter
Heat Exchange Surface Area Increased (PUHZ-RP100~170)
By extending the heat exchanger horizontally the total heat
Redesigned Grille Shape
The shape of the air outlet grille has been redesigned
to reduce pressure loss, in turn improving heat
exchange surface area is increased, again resulting in greater
overall heat exchange.
exchange performance.
Increase in heat exchanger
surface area
Heat exchanger
Heat exchanger
<PUHZ–RP-HA>
Inflexed Fan (PUHZ-RP100~170)
Adoption of a fan with improved ventilation characteristics and
a newly designed rear edge that suppresses wind turbulence
raises fan operation efficiency.
<PUHZ–RP-KA>
Heat Interchanger (HIC) Added (PUHZ-RP140)
An HIC circuit has been added to improve energy efficiency
during cooling operation. To achieve this liquid refrigerant is
rerouted, transformed into a gas state, and injected back into
the system to increase the overall pressure of refrigerant being
sent to the compressor. This results in reduced loading on the
compressor and an overall increase in efficiency.
Cooling operation
Indoor
HEX
LEV B
A
Heat interchanger (HIC)
w/o HIC circuit
w/ HIC circuit
4
Outdoor
HEX
Power receiver
A
Fan rear edge
Compressor
LEV A
Heat
interchanger
LEV C
(HIC)
Increasing the pressure of the
refrigerant sent to the compressor
reduces the compression load
Advanced Technology for High Efficiency
Leading-edge Technology,
High Efficiency Assured
Reluctance DC Rotary Compressor (PUHZ-RP71)
DC Fan Motor
All reluctance DC motors in Mr. Slim PUHZ-RP71 outdoor
A highly efficient DC motor has been installed to drive the
units incorporate a rotor equipped with powerful neodymium
outdoor unit fan, resulting in up to 60% higher efficiency when
magnets. The magnetic and reluctance torque produced by
compared to an equivalent AC motor.
these magnets results in more efficient operation.
Vector-wave Eco Inverter
This inverter monitors the varying compressor motor frequency
DC compressor motor (rotor)
and creates the most efficient waveform for the motor
speed. As a result, operating efficiency in all speed ranges is
improved, less power is used, and annual electricity costs are
reduced.
Smooth AC Wave Pattern
The inverter has been made more compact by inserting the
Neodymium
magnets
Magnetic torque + Reluctance torque
Highly Efficient Scroll Compressor
(PUHZ-RP100~170)
circuitry inside a synthetic resin moulding.
To ensure quiet operation, soft PWM (pulse width modulation)
control is used to prevent the metallic whine associated with
conventional inverters.
Sine-wave drive soft PWM
Higher efficiency has been achieved by adding
a frame compliance mechanism to the DC
scroll compressor. The mechanism allows
movement in the axial direction of the frame
supporting the cradle scroll, thereby greatly
reducing the leakage and friction loss, and
ensuring extremely high efficiency at all speeds.
Power Receiver and Twin LEV Control
Fixed
scroll
Thrust gas power:
minimum
Leaking loss: minimum
Mitsubishi Electric has developed a power receiver and
twin linear expansion valves (LEVs) that optimise the
performance of the compressor. By ensuring optimum control
Thrust friction loss: minimum
Secondary back-pressure
chamber minimises thrust
friction loss.
Frame Cradle
scroll
in response to the operating waveform and outdoor
temperature, this technology is tailored to the characteristics
of the new refrigerant to enhance operating efficiency.
Primary back-pressure
chamber minimises
leaking loss.
5
MA Wired Wall Controller
PAR-32MAA
The PAR-32MAA is now easier to read thanks to the
Display Example [Operation Mode]
use of a full dot liquid-crystal display with backlight.
Full Dot LCD
PAR-32MAA
Control panel operation in
eight different languages
Adoption of a menu format that has reduced the
number of operating buttons has also ensured
•English
•Spanish
•Italian
•German
•French
•Russian
•Portuguese
•Swedish
increased ease of use.
New Simple MA Remote Controller
Backlit LCD
PAC-YT52CRA
Pressing the
Liquid-crystal display (LCD) with backlight for operation
Multi Language Display
button will switch
the vane direction.
in dark conditions.
Flat Back
The slim and flat-back shape makes installation easier without
requiring a hole in the wall. Thickness is 14.5mm or less.
Vane Angle Setting
The vane button has been added to allow users to change the
airflow direction (ceiling cassette and wall-mounted units).
Zone Controller
• Adjustable vane directions vary depending
on the indoor unit model to be connected.
• If the unit has no vane function, the vane
direction cannot be set. In this case, the
vane icon flashes when the
button
is pressed.
PAC-ZC40(H/L)-E/PAC-ZC80(H/L)-E
The PAC-ZC40~80 Zone Controller brings expanded
functionality and interaction to realise even greater energy
savings. With the ability to control up to 8 zones*, and
equipped with automatic unloading/ramping and three built
in sensor functions (temperature, occupancy, brightness), the
Zone Controller brings intuitive, yet simple control to a whole
new level.
Temperature Sensor
Sensing the return air of the indoor ducted unit is not always
ideal. With an inbuilt thermostat (PAR-ZC01ME-E Wall
Controller) the Zone Controller allows the actual usable space
temperature to be measured, offering a more realistic and
timely temperature measurement where it is needed most.
Occupancy Sensor
Incorporating a built in occupancy sensor, the Zone Controller
(via the PAR-ZC01ME-E Wall Controller) constantly monitors
the usable area to detect vacancy. Once detected, the Zone
Controller uses internal functions to implement one of 4
user defined energy-save control options to reduce energy
consumption; turn the unit on/off, lower the fan speed,
temperature offset, or turn user designated zones on/off.
Brightness Sensor
Working in conjunction with the
Occupancy Sensor, the Brightness Sensor
can be set to maximise energy savings
when it detects user defined “Light” or
“Dark” conditions (lux values).
Backlit LCD Touch Screen
Features a liquid-crystal display (LCD) with backlight for
operation in dark conditions. For ease of use the user defined
coloured LED indicator (at the bottom of the controller) lights
up to indicate the current operation mode i.e. red for heating,
blue for cooling, green for night setback.
Optional Wi-Fi Control
Advanced temperature monitoring and management is available
with the addition of the award winning Mitsubishi Electric
Wi-Fi Control. Now you can control,
monitor and schedule which zones your
ADVANCED
ducted heat pump is controlling in real
time from anywhere via your smart
phone, tablet or online account.
OPTIONAL UPGRADE
*PAC-ZC80 only. PAC-ZC40 only allows control of 4 zones. Compatible with
either 24V or 240V damper options. Optional: 1x additional PAR-ZC01ME-E
controller and 2x thermistors (PAC-SE41TS-E) can be installed.
6
Operation Control Functions
Energy Efficient Control: PAR-32 & PAC-ZC Only
Energy Saving Schedule
Night Setback
Precise control of power consumption (PAR-32 Only)
Keep desired room temperatures automatically
Incorporating advanced Energy Saving Scheduling, the
This function monitors the room temperature and automatically
PAR-32MAA Wired Wall Controller allows complete energy
activates heating mode when the temperature drops below the
management optimisation. System capacity can be adjusted
preset minimal temperature setting. It has the same function
(to 0, 50, 60, 70, 80 or 90% of maximum capacity) to reduce
for cooling, automatically activating cooling mode when the
total energy consumption. Additionally, up to 4 start/finish
temperature rises above the preset maximum temperature
patterns can be set per day to ensure optimal energy efficiency
setting.
without compromising comfort.
Operation Lock
Fixed temperature setting promotes energy savings
Setting Pattern Example
Start Time
Finish Time
Adjusted Capacity Level
In addition to operation start/stop, the operation mode,
temperature setting and airflow direction can be locked.
8:15
>
12:00
80%
12:00
>
13:00
50%
an appropriate temperature is constantly maintained, leading
13:00
>
17:00
90%
to energy savings. This feature is also useful in preventing
17:00
>
21:00
50%
erroneous operation or tampering.
Unwanted adjustment of temperature settings is prevented and
Recommended for office, school, halls, hospital, computer server facility.
Temperature Range Restriction
Auto-Off Timer
Prevents overheating/overcooling
Using a temperature that is 1°C lower/higher for heating/
Turns heating/cooling off automatically after preset
time elapses
cooling results in a 10% reduction in power consumption.*
When using the Auto-Off Timer, even if you forget to turn the
Temperature Range Restriction limits the maximum and
minimum temperature settings, contributing to the prevention
of overheating/overcooling.
unit off, operation stops automatically after the preset time
elapses, thereby preventing wasteful operation. The AutoOff Timer can be set in 10 minute units, in a range between
*In-house calculations.
30 minutes and 4 hours. This eliminates all anxiety about
forgetting to turn the unit off.
Cooling/Dry
Setting example of minimum temp. in 25°C
19°C
30°C
Possible temperature range setting
25°C
Lower temperature limit
Lower temperatures
cannot be selected
30°C
To prevent excessive cooling
Recommended for office, restaurant applications.
Recommended for meeting room, changing room applications.
Weekly Timer
Set up to 8 on/off patterns per day including
temperature control
The Weekly Timer enables the setting of operation start/stop
times and the adjustment of temperature as standard features.
Up to 8 patterns can be set per day, providing operation that
matches the varying conditions of each period, such as the
Auto-Return
Prevents wasteful operation by automatically returning to the
preset temperature after specified operating time
After adjusting the temperature for initial heating in winter
number of customers in a store.
Weekly Timer cannot be used when On/Off Timer is in use.
Setting Example (restaurant in summer time)
Preparation
26
the temperature setting to its original value. The Auto-Return
function automatically resets the temperature back to the
original setting after a specified period of time, thereby
preventing overheating/overcooling. The Auto-Return activation
time can be set in 10-minute units, in a range between 30
and 120 minutes.
Auto-Return cannot be used when Temperature Range Restriction is in use.
Temperature setting (°C)
or cooling on a hot summer day, it is easy to forget to return
1
Busy
hours
Set to lower temperature
Off-peak
hours
7
25
Opening
time
2
24
4
5
3
23
8
Closing time
6
Lunch time
Dinner time
8-pattern setting
22
0
Set to higher temperature
10
12
14
16
18
20
Necessary to change temperature settings for cooling/heating times.
*Joint research conducted with Japan Facility Solutions, Inc.
22
24 Time (hr)
7
Installation/Maintenance Support Functions
Manual Vane Angle Setting
Automatic Grille Lowering Operation
(4-way ceiling cassette)
(Optional PLP-6BAJ)
Direction of vertical airflow for each vane can be set
Easily raise/lower panels using the remote controller
All Deluxe PLA Cassettes allow the vertical airflow
direction for each individual vane to be manually
adjusted/set. As a result, draughts can be minimised
without compromising system performance. Seasonal
settings such as switching between cooling
and heating can be easily changed as well.
In conjunction with the optional PLP-6BAJ grille, automatic
grille lowering function capable of stopping at eight different
heights is available to simplify filter maintenance.
Inspection Guidelines
Once Smooth Maintenance is completed a table of
information is displayed. This information can then be
Smooth Maintenance
manually plotted onto the two graphs (heating and cooling)
Outdoor unit data can be accessed, enabling fast
maintenance
to see if the unit is operating normally (according to
Japanese standard conditions).
Using Stable Operation Control (fixed frequency) of the Smooth
Operation
Maintenance function, the operating status of the inverter can
be checked easily via the screen on the remote controller.
Item
( 6 OU TH4 temp.) – ( 7 OU TH6 temp.)
Cooling
( 9 IU air temp.)
Temp.
difference
Smooth Maintenance Function Operating Procedure
– (10 IU HEX temp.)
( 6 OU TH4 temp.) – (10 IU HEX temp.)
Heating
(10 IU HEX temp.)
(°C)
Select maintenance
mode
Activate Stable
Operation
45
40
Cooling
operation
Inspection C
35
Data is displayed
Heating
operation
30
9
10
25
20
Normal
10
35
Inspection C
Filter inspection
20
5
10 20 30 40 50 60 70 80
6
25
7
Normal
Inspection B
10
Inspection A
5
9
15
Inspection B
10
0
(°C)
45
40
30
Filter inspection
15
Display information (11 items)
– ( 9 IU air temp.)
(°C)
0
Inspection A
10 20 30 40 50 60 70 80
(°C)
6
10
Compressor
Result
1
COMP. current (A)
2
COMP. run time (hr)
3
COMP. ON/OFF (times)
Normal
Normal operating status.
4
COMP. frequency (Hz)
Filter inspection
Filter may be blocked.*1
Outdoor Unit
Capacity is reduced. Detailed inspection is necessary.
5
Sub cool (°C)
Inspection B
Refrigerant level is low.
6
OU TH4 temp. (°C)
Inspection C
Filter or indoor unit heat exchanger is blocked.
7
OU TH6 temp. (°C)
8
OU TH7 temp. (°C)
Indoor Unit
9
IU air temp. (°C)
10
IU HEX temp. (°C)
11
IU filter operating time* (hr)
*IU filter operating time is the time elapsed since filter was reset.
8
Inspection A
*1 Due to indoor and outdoor temperatures, “Filter inspection” may be displayed even if the
filter is not blocked.
•The above graphs are based on trial data. Results may vary depending on
installation/temperature conditions.
•Stable operation may not be possible under the following temperature conditions:
a) In cooling mode when the outdoor induction temperature is over 40°C or the indoor induction temperature is below 23°C.
b) In heating mode when the outdoor induction temperature is over 20°C or when the indoor induction temperature is over 25°C.
•If the above temperature conditions do not apply and stable operation is not achieved
after 30 minutes has passed, please inspect the units.
•The operating status may change due to frost on the outdoor heat exchanger.
Rotation, Back-Up and 2nd Stage Cut-In Functions
Rotation and Back-Up Functions
(PAR-32MAA)
With the ability to set rotation and/or backup functionality,
Mr. Slim Series systems are the perfect solution for future
proofing your comfort. Setting main and sub units to take
turns operating, according to a rotation interval setting,
increases overall system longevity. Meanwhile setting the
Back-Up function ensures automatic redundancy in the
event of unit malfunction.
System Image
Main
Unit
O/U-1
O/U-2
I/U-1
I/U-2
O/U:Outdoor unit
Sub
Unit I/U:Indoor unit
R/C:Wired remote
controller
R/C
2nd Stage Cut-In Function
The 2nd Stage Cut-In Function is perfect for applications
where cooling load requirements fluctuate. As this load
requirement increases above the desired setting, standby
units are triggered into operation to ensure constant
provision of the optimum level of comfort in the most
energy efficient manner. Once the room temperature falls
4°C, 6°C, or 8°C below the predetermined setting, the
standby unit ceases to operate to ensure excess cooling
does not compromise comfort.
System Constraint
The 2nd Stage Cut-In Function is only available in
cooling mode.
Easy Maintenance
Operation Pattern
Back-Up Function only
Error occurs on main unit.
Main > Sub
Start operation
Main
Unit
I/U-1
Run
Abnormal condition
Sub
Unit
I/U-2
Stop
Run
Rotation Function & Back-Up Function
Start operation
Main
Unit
I/U-1
Run
Sub
Unit
I/U-2
Stop
Main>Sub
1-28 DAYS
Main>Sub
Error occurs on main unit.
Main > Sub
Stop
Run
Abnormal condition
Run
Stop
Run
1-28 DAYS
(Ex: When the request code is “313”, each unit operates alternately in daily cycle.)
Operation Pattern (when cooling)
2nd Stage Cut-In Function
Start operation
Main
Unit
I/U-1
Run
Sub
Unit
I/U-2
Stop
Room temp. ≥ Set point
Sub unit starts operation
Room temp. ≥ Set point -4°C
Sub unit stops
Stop
(Mr. Slim Power Inverter only)
Operation of Mr. Slim Power Inverters is almost maintenancefree. Now you can monitor operation data of the indoor and
outdoor units via the PAR-32MAA Wired Wall Controller. This
controller also lets you view the operating frequency, allowing
easier inspection/diagnostics.
Easy Maintenance Information
Compressor
Indoor Unit
Outdoor Unit
1
Accumulated
Operating time
(×10hr)
4
Heat exchanger
temperature (˚C)
7
Intake-air
temperature (˚C)
2
Number of ON/
OFF times (×100
times)
5
Discharge
temperature (˚C)
8
Heat exchanger
temperature (˚C)
3
Operating current
(A)
6
Outdoor-air
temperature (˚C)
9
Filter operating
time* (hr)
Refrigerant Leakage Check
All Mr. Slim Power Inverter units come equipped with a useful
new “Refrigerant Leakage Check” function. Using a wired
remote controller, it is easy to check if refrigerant has been lost
over a long period of use. This reduces service time and gives
an added sense of safety.
*The filter operating time is the time elapsed since the filter button was reset.
9
Product Line-Up
4-WAY CEILING
CASSETTE
SLZ
COMPACT
BULKHEAD
p.18
PLA
p.12
SEZ
CEILING
SUSPENDED
p.18
PCA
2.5kW
SLZ-KA25VAQ(L)
3.5kW
SEZ-KD35VAQ
5.0kW
SLZ-KA50VAQ(L)
SEZ-KD50VAQ
PCA-RP50KAQ
PLA-RP60BA
SEZ-KD60VAQ
PCA-RP60KAQ
PLA-RP71BA
SEZ-KD71VAQ
6.0kW
7.1kW
PCA-RP71HAQ
PCA-RP71KAQ
10.0kW
PLA-RP100BA
PCA-RP100KAQ
PLA-RP125BA
PCA-RP125KAQ
PLA-RP140BA
PCA-RP140KAQ
12.5kW
14.0kW
17.0kW
Remote
controller
Standard for
SLZ-VAQ
Standard for
SLZ-VAL
10
Optional
Standard for SEZ-VAQ
OPTIONAL
Standard
Optional
p.16
CEILING
CONCEALED
PEAD
WALL
MOUNTED
p.14
PEA
p.15
PKA
OUTDOOR
UNIT
p.17
Outdoor Unit
SUZ-KA25VA
SUZ-KA35VA
SUZ-KA50VA
SUZ-KA60VA
PEAD-RP71JAA
PKA-RP71KAL*
SUZ-KA71VA
PKA-RP100KAL
PUHZ-RP100VKA
PEAD-RP100JAA
PEA-RP100GAA
PEAD-RP125JAA
PEA-RP125GAA
PUHZ-RP125VKA
PEAD-RP140JAA
PEA-RP140GAA
PUHZ-RP140VKA
PEA-RP170WJA
Optional
Optional
OPTIONAL
OPTIONAL
PUHZ-RP71VHA
PUHZ-RP170VKA
Optional
Standard
*PUHZ-RP71VHA only
11
Deluxe PLA Series Cassettes
4-Way Ceiling Cassette
Advancements in Deluxe PLA Series Cassettes improve style and performance for ensured indoor comfort
Wide Airflow
Conventional model
Deluxe PLA Series Cassettes utilise
wide-angle outlets to distribute airflow
to all corners of the room, ensuring
the room is cooled/heated in an
even and sufficient manner. Both
horizontal airflow and fan speed have
been reduced by 20% compared to
conventional models, contributing to
increased comfort for occupants.
PLA-RP**BA
With the ability to independently control each vane’s airflow
pattern, Deluxe PLA Series Cassettes are perfect for both
residential and office/commercial environments. Simply adjust
airflow via the PAR-32MAA Wired Controller to suit the interior
layout and seasonal conditions, ensuring even temperature
distribution at all times.
Settings can be changed anytime using a wired remote controller.
Using wired remote controller, set
airflow direction for each vane
(manual setting also possible).
Fixed
Set by remote
controller
Vertical flow
The Horizontal Airflow function prevents
both cold draughts and/or heating airflow
from striking occupants directly, thereby
keeping people from becoming overchilled/over-heated.
Auto Fan Speed Mode
Independent Vane Direction Setting (P Series Outdoor only)
Horizontal flow
Less Cold Draught
Wired remote controller
(PAR-32MAA) has Independent
Vane Direction Setting.
This function is only available
when indoor unit connects with
PUHZ series.
The fan speed on Deluxe PLA Series Cassettes is adjusted
automatically, thereby maintaining a comfortable environment
at all times. At the start of operation, a high fan speed
achieves quick heating/cooling of the room. Once the desired
temperature is reached, the fan speed is reduced for stable,
more efficient heating/cooling and greater comfort.
Fan speed setting by remote controller (four levels)
Lo
Mi1
Mi2
Hi
Auto
Special setting is required for wireless remote controller
Quiet Operation
An improved airflow path and powerful
high-capacity flow fan contribute to quieter
operation.
Power flow fan
“Pure White” Colour
Wave Airflow Mode for Heating
Advanced control of vanes, called Wave Airflow, provides
even greater heat distribution by periodically moving vanes
up and down to provide a consistent temperature throughout
the room.
Stylish, pure white coloured panels and wired remote
controller present a clean, streamlined installation that is
a suitable match for any interior.
Wave control effect thermograph
•Stylish indoor unit vane covers (when unit is turned off)
Vertical flow
Other Features
•Maximum upward draining of 850mm
Swing mode
•Wireless remote controller option available
•Duct flange for fresh-air intake
•Branch duct
Temperature gap with uneven
temperature distribution
Temperature gap is decreased,
and room is warmed uniformly
Automatic Grille Lowering Function (Optional)
Easy to use/simple maintenance
“Wave Airflow” operation image
1.2m
An automatic grille lowering function capable
of stopping at eight different heights is available to
simplify filter maintenance.
1.6m
2.0m
2.4m
Vertical flow
Vertical flow
Vertical flow
Vertical flow
Simultaneous horizontal and vertical operation ensure a comfortable room from corner to corner.
12
Packaged elevating (up-down)
controller in the grille
(PLP-6BAJ) can be used when
outdoor unit is both PUHZ
series and SUZ series.
Wired remote controller (PAR32MAA) has automatic grille
lowering function. This function
is only available when indoor
unit connects with PUHZ series.
Elevating
(up-down)
controller
2.8m
3.2m
3.6m
4.0m
Automatic
elevation to
four metres
Deluxe PLA Series 4-way Cassettes can be equipped
with the i-See Sensor, a radiation-based sensor that
monitors floor-level temperatures throughout the room
to ensure room comfort.
The i-See Sensor works to
ensure even temperature
distribution and save
energy (requires optional
corner panel).
i-See Sensor Operation
The i-See Sensor rotates 90° every
two minutes*, taking 5-second
measurements at each position to
accurately determine floor-level temperatures on all
sides of the room. The i-See Sensor calculates the
temperature by measuring the infrared rays emanating
from the walls and floors, and measuring the floor-level
temperature.
360°
Floor-level temperature
measured throughout the room.
i-See Sensor improves energy
efficiency and enhances room comfort.
90°
rotation
The i-See Sensor is an innovative Mitsubishi Electric
technology that uses a radiation-based sensor to monitor
the temperature throughout the entire room. When
connected to the air conditioner control panel, the i-See
Sensor works to maximise room comfort through 360°
sensing that covers the whole floor space, giving a more
accurate and even temperature reading.
90°
rotation
5 sec
measurement
5 sec
measurement
90°
rotation
5 sec
measurement
5 sec
measurement
*The sensor rotates 360 degrees once every two minutes when there is significant
temperature disparity and once every five minutes when a stable, even temperature has
been reached.
“I Feel” Temperature Control
The sensory temperature is calculated by measuring the airintake temperature and the floor temperature. This technology
makes it possible to avoid overcooling or overheating.
Without i-See Sensor
Indoor temperature
Indoor
temperature
detecting
sensor
detecting sensor
Only intake-air temperature
at the ceiling is measured,
resulting in uneven
temperature distribution.
With i-See Sensor
Indoor temperature
Indoor
temperature
detecting
sensor
detecting sensor
Area
Areawhich
whichthe
the
“i-see
i-see Sensor”
Sensor
checks
checks
360°
sensing
Area which the
sensor checks
Both floor-level and intake-air
temperatures are measured, providing
operation that creates a comfortable
room environment from ceiling to floor.
2.7m
Heating
Heating
11.5m
Set temperature: 23°C
Set temperature: 20°C
with i-See Sensor + Auto Fan Speed
without i-See Sensor
Specifications: 4-way ceiling-cassette (PLA)
Indoor unit
PLA-RP60BA
PLA-RP71BA
PLA-RP71BA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA
Outdoor unit
SUZ-KA60VAD
SUZ-KA71VAD
PUHZ-RP71VHA5
PUHZ-RP100VKA2
PUHZ-RP125VKA2
PUHZ-RP140VKA2
Function
Capacity (min.-max.)
(kW)
Input
(kW)
Cooling
Heating
Cooling
Heating
Cooling
6.1 (1.1-6.3)
6.9 (0.9-8.0)
7.1 (0.9-8.1)
8.0 (0.9-10.2)
7.1 (3.3-8.1)
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0)
1.78
1.97
2.07
2.19
2.09
2.17
2.50
2.95
3.80
3.71
3.97
4.43
Rated EER/COP
3.80
3.99
3.46
3.71
3.42
3.59
3.98
3.74
3.25
3.71
3.25
3.55
Rated AEER/ACOP
3.73
3.92
3.41
3.66
3.24
3.42
3.65
3.49
3.07
3.51
3.17
3.39
AEER/ACOP (part-load %) *
4.13
PLA-RP60BA
Indoor unit
PLA-RP71BA
PLA-RP100BA
PLA-RP125BA
PLA-RP140BA
V: Single-phase, 50Hz, 230V
Power supply
Airflow (Lo-Mi2-Mid-Hi)
Sound pressure level
Dimensions
PLA-RP71BA
3.95
CMM
12-14-16-18
14-16-18-21
14-16-18-21
20-23-26-30
22-25-28-31
24-26-29-32
L/S
200-233-267-300
233-267-300-350
233-267-300-350
334-384-434-501
367-417-467-517
400-434-484-534
(dB)
28-29-31-32
28-30-32-34
28-30-32-34
32-34-37-40
34-36-39-41
36-39-42-44
Height
(mm)
Width
(mm)
Depth
(mm)
Weight
(kg)
Unit: 258, Panel: 35
Unit: 298, Panel: 35
Unit: 840, Panel: 950
Unit: 840, Panel: 950
Unit: 23, Panel: 6
Unit: 25, Panel: 6
Unit: 27, Panel: 6
*MEPS compliant at part load
13
ADVANCED
OPTIONAL UPGRADE
Available on PEAD
PEAD Series
Ceiling Concealed
The thin, low-profile, ceiling-concealed indoor units of the
PEAD Series are the perfect answer for air conditioning
requirements of buildings with minimum ceiling installation
space and wide-ranging external static pressure. Energysaving efficiency has been improved, thereby reducing
electricity consumption and contributing to further reductions
in operating cost.
250mm
Compact Indoor Units
Lighter Weight
The height of the PEAD (7.1kW~14.0kW) models has
Compared to the previous PEA-RP-EAQ (7.1kW~14.0kW)
been unified to 250mm. Compared to the PEA-RP***GAA
models, the unit weight has been reduced by an average of
models, the height has been reduced by as much as 150mm,
27kg. This significant weight reduction has led to increased
making installation possible in low ceilings with minimal
ease of installation.
clearance space.
Wide Selection of Fan Speeds and External Static Pressure
High Energy-Saving Efficiency
All PEAD models incorporate five-stage external static pressure
Compared to the previous PEA-RP-EAQ (7.1kW~14.0kW)
conversions and three fan speed selections, offering the ultimate
models, the PEAD-RP models achieve enhanced energy
in comfort diversity. With a wide range of adjustable static
savings through adopting a highly efficient DC fan motor. This
pressures (35-125Pa), PEAD Series units are applicable to a
contributes to an impressive reduction in electricity costs.
wide range of building types and applications.
Capacity Rated EER/COP
10.0kW
12.5kW
14.0kW
PEA-RP
PEAD-RP
Zone Controller (Optional)
Rated EER
3.24
3.90
20% UP
The optional Zone Controller brings intuitive
Rated COP
3.50
3.25
08% DOWN
Rated EER
2.92
3.38
17% UP
yet simple control to a whole new level,
Rated COP
3.89
4.15
07% UP
Rated EER
2.85
3.29
15% UP
automatic unloading/ramping and energy
Rated COP
3.74
4.08
09% UP
saving sensor functions. Find out more
with the ability to control up to 8 zones,
about this controller on page 6.
Specifications: Ceiling-concealed (PEAD)
Indoor Unit
Outdoor Unit
PEAD-RP71JAA
PEAD-RP100JAA
PEAD-RP125JAA
PEAD-RP140JAA
SUZ-KA71VAD
PUHZ-RP100VKA2
PUHZ-RP125VKA2
PUHZ-RP140VKA2
Function
(kW)
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min.-max.)
(kW)
7.1 (0.9-8.1)
8.0 (0.9-10.2)
10.0 (4.9-11.4)
11.2 (4.5-14.0)
12.0 (5.5-14.0)
14.0 (5.0-16.0)
13.0 (6.2-15.3)
16.0 (5.7-18.0)
Input
2.10
2.04
2.77
2.72
3.60
3.50
3.91
4.04
Rated EER/COP
3.38
4.14
3.90
4.53
3.38
4.15
3.29
4.08
Rated AEER/ACOP
3.33
4.08
3.60
4.17
3.18
3.90
3.12
3.86
PEAD-RP71JAA
Indoor Unit
PEAD-RP100JAA
PEAD-RP140JAA
CMM
17.5-21-25
24-29-34
29.5-35.5-42
32-39-46
L/S
292-350-417
400-483-567
492-592-700
533-650-767
Sound Pressure Level
(dB)
30-34-39
33-38-42
36-40-44
40-44-49
Return Air Spigot Size
(mm)
1,058×210
1,358×210
1,358×210
1,558×210
(mm)
1,060×178
1,360×178
1,360×178
1,560×178
Airflow
35/50/70/100/125
External Static Pressure Pa
Supply Air Spigot Size
Dimensions
Weight
Energy Star ®
14
PEAD-RP125JAA
V: Single-phase, 50Hz, 230V
Power Supply
Height
(mm)
Width
(mm)
Depth
(mm)
(kg)
250
1,400
1,100
1,600
732
29
38
39
43
ADVANCED
OPTIONAL UPGRADE
Available on PEA
PEA Series
Ceiling Concealed
The PEA Series high static airflow allows air to be directed
to different areas of your home or office with ease, ideal for
heating or cooling a number of rooms at once.
PEA-RP100~140GAA
Flexible Duct Design Enables Use of High-Pressure Static Fan
400mm
With a maximum 150Pa external static high-pressure setting,
PEA Series models offer complete flexibility in duct design.
The increased variation in airflow options ensures operation
Versatile and Easy Installation Options
that best matches virtually all room layouts.
PEA Series models offer both versatility and ease of
installation/application; for example, it is possible to adjust the
distance between the air-intake and air-outlet vents to create
the optimal airflow configuration.
Long rectangular room
Room with fixed
ceiling fixtures
Zone Controller (Optional)
The optional Zone Controller brings intuitive
yet simple control to a whole new level,
with the ability to control up to 8 zones,
automatic unloading/ramping and energy
saving sensor functions. Find out more
L-shaped room
about this controller on page 6.
Specifications: Ceiling-concealed (PEA)
Indoor unit
Outdoor unit
PEA-RP100GAA
PEA-RP125GAA
PEA-RP140GAA
PEA-RP170WJA
PUHZ-RP100VKA2
PUHZ-RP125VKA2
PUHZ-RP140VKA2
PUHZ-RP170VKA2
Cooling
Function
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min.-max.)
(kW) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.5 (5.5-14.0) 14.0 (5.0-16.0) 13.5 (6.2-15.3) 16.0 (5.7-18.0) 16.0 (9.0-20.0) 20.0 (9.5-22.4)
Input
(kW)
3.05
3.16
3.97
3.27
4.19
3.90
5.00
6.00
Rated EER/COP *1
3.96
4.47
3.27
4.29
3.23
4.14
3.64
3.84
Rated AEER/ACOP
3.65
4.12
3.10
4.04
3.07
3.93
3.47
3.69
Indoor unit
PEA-RP100GAA
Power supply
PEA-RP125GAA
PEA-RP140GAA
PEA-RP170WJA
CMM
34-42 (Lo-Hi)
48-60 (Lo-Hi)
50-72 (Lo-Hi)
L/S
560-700 (Lo-Hi)
800-1000 (Lo-Hi)
833-1,200 (Lo-Hi)
External static pressure Pa
60/75/100/150
50/100/150
Sound pressure level *2
(dB)
Height
(mm)
400
470
Width
(mm)
1,400
1,370
Depth
(mm)
634
1,120
(kg)
63
108
Weight
470mm
Single-phase, 50Hz, 230V
Airflow
Dimensions
PEA-RP170WJA
42-45
39-42
38-41-44
Energy Star ®
*1 Rated EER/COP for PEA-RP170WJA are measured at ESP 75 Pa
*2 Sound pressure level for PEA-RP170WJA are measured in anechoic chamber at ESP 150 Pa
15
PCA Series
Ceiling Suspended
PCA Series high performance units are designed for style and
efficiency. A stylish indoor unit design and airflow settings
for both high and low-ceiling interiors expand installation
possibilities. With four speed settings and auto air-speed
adjustment, PCA Series units provide energy efficient
comfort no matter what the season.
PCA-RP50-140KAQ
230mm
Stylish Indoor Unit Design
A stylish square-like design is adopted for the indoor units of
Fresh Outside-Air Intake
all PCA Series models. As a result, the units blend in better
Units are equipped with a knock-out
with the ceiling.
hole that enables the induction of
fresh outside-air.
Optional Drain Pump
The pumping height of the optional
Equipped with High/Low-Ceiling Modes
drain pump has been increased
All PCA Series units are equipped with high and low-ceiling
from 400mm to 600mm, expanding
operation modes, that make it possible to switch the airflow
flexibility in choosing unit location
volume to match room height. The ability to choose the
during installation work.
optimum airflow volume makes it possible to optimise the
breezy sensation felt throughout the room.
Equipped with Automatic Air-Speed Adjustment
In addition to the conventional 4-speed setting, units are now
Capacity
High ceiling
Standard ceiling
Low ceiling
equipped with an automatic air-speed adjustment mode. This
PCA-RP50
3.5m
2.7m
2.5m
setting automatically adjusts the air-speed to conditions that
PCA-RP60
3.5m
2.7m
2.5m
2.5m
PCA-RP71
3.5m
2.7m
operation, the airflow is set to high-speed to quickly heat/cool
PCA-RP100
4.2m
3.0m
2.6m
PCA-RP125
4.2m
3.0m
2.6m
the room. When the room temperature reaches the desired
PCA-RP140
4.2m
3.0m
2.6m
match the room environment. At the start of heating/cooling
setting, the airflow
speed is decreased
PCA-RP71HAQ
Gentle
Strong
automatically for
comfortable heating/
After room
temperature is
stabilised
Start of
cooling/heating
cooling operation.
280mm
Specifications: Ceiling-suspended (PCA)
Indoor unit
PCA-RP50KAQ
PCA-RP60KAQ
PCA-RP71KAQ
PCA-RP71KAQ
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
PCA-RP71HAQ
Outdoor unit
SUZ-KA50VAD
SUZ-KA60VAD
SUZ-KA71VAD
PUHZ-RP71VHA5
PUHZ-RP100VKA2
PUHZ-RP125VKA2
PUHZ-RP140VKA2
PUHZ-RP71VHA5
Cooling
Function
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min.-max.)
(kW) 4.9 (1.1-5.6) 5.5 (0.9-6.6) 5.7 (1.1-6.3) 6.9 (0.9-8.0) 7.1 (0.9-8.1) 7.9 (0.9-10.2) 7.1 (3.3-8.1) 8.0 (3.5-10.2) 10.0 (4.9-11.4) 11.2 (4.5-14.0) 12.0 (5.5-14.0) 14.0 (5.0-16.0) 13.0 (6.2-15.3) 16.0 (5.7-18.0) 7.1 (3.3-8.1) 7.6 (3.5-10.2)
Input
(kW)
1.49
1.68
1.77
2.02
2.06
1.96
2.21
2.23
2.63
3.02
4.05
3.88
3.97
4.43
2.21
2.23
Rated EER/COP
3.48
3.49
3.84
3.87
3.51
3.99
3.66
3.58
3.79
3.73
3.28
3.58
3.24
3.51
3.13
3.44
Rated AEER/ACOP
3.41
3.44
3.76
3.81
3.46
3.93
3.45
3.41
3.49
3.48
3.09
3.39
3.07
3.35
2.98
3.27
AEER/ACOP (part-load %) *
4.19
PCA-RP50KAQ
Indoor unit
PCA-RP60KAQ
PCA-RP71KAQ
Airflow (Lo-Mi2-Mid-Hi)
Sound pressure level
Weight
PCA-RP100KAQ
PCA-RP125KAQ
PCA-RP140KAQ
PCA-RP71HAQ
Single-phase, 50Hz, 230V
V: Single-phase, 50Hz, 230V
Power supply
Dimensions
PCA-RP71KAQ
3.91
CMM
10-11-13-15
15-16-17-19
16-17-18-20
22-24-26-28
23-25-27-29
24-26-29-32
17-19
L/S
167-183-217-250
250-267-283-317
267-283-300-333
367-400-433-467
383-417-450-483
400-433-483-533
283-317
(dB)
32-34-37-40
33-35-37-40
35-37-39-41
37-39-41-43
39-41-43-45
41-43-45-48
34-38
Height
(mm)
Width
(mm)
Depth
(mm)
(kg)
280
230
960
1,280
25
32
1,136
1,600
650
680
36
38
39
41
* MEPS compliant at part load
16
PKA Series
Wall Mounted
The large capacity PKA Series is both elegant and compact.
With greater placement options and high airflow, PKA Series
units are ideal light commercial uses (i.e. offices, stores, and
server rooms).
Removable Intake Grille Filter Allowing Easy Cleaning
Filter slides out and can be washed in water.
Suitable for Server Room Applications
The PKA Series provides an economical split system solution
for high sensible applications due to their larger coil size. As a
result they are ideal for applications such as server rooms and
laboratories where there is a need for sensible cooling.
Wired Remote Controller Available (Optional)
A separately sold wired remote controller
and terminal block are available to
suit various installation sites. When
connecting a wired remote controller the
MAC-333IF-E interface is not required.
Auto-Vane Shutter
The vane closes automatically when the unit is not running,
creating a sleek flat finish that is aesthetically pleasing.
Specifications: Wall-mounted (PKA)
Indoor unit
Outdoor unit
Function
Capacity (min.-max.)
(kW)
Input
(kW)
PKA-RP71KAL
PKA-RP100KAL
PUHZ-RP71VHA5
PUHZ-RP100VKA2
Cooling
Heating
7.1 (3.3-8.1)
8.0 (3.5-10.2)
Cooling
Heating
10.0 (4.9-11.4) 11.2 (4.5-14.0)
1.96
2.13
2.90
3.10
Rated EER/COP
3.62
3.79
3.60
3.50
Rated AEER/ACOP
3.42
3.59
3.33
3.28
V: Single-phase, 50Hz, 230V
Power supply
Airflow (Lo-Mid-Hi)
Sound pressure level
Dimensions
Weight
PKA-RP100KAL
PKA-RP71KAL
Indoor unit
CMM
18-20-22
20-23-26
L/S
300-333-367
333-383-433
(dB)
39-42-45
41-45-49
Height
(mm)
365
Width
(mm)
1,170
Depth
(mm)
295
(kg)
21
17
ADVANCED
OPTIONAL UPGRADE
Available on SEZ
SLZ /SEZ Series
4-Way Cassette and Compact Ceiling-concealed
Compact, quiet concealed indoor units equipped with cutting-edge control for enhanced comfort.
Compact Designs
Energy-Saving Operation
There are models with capacity ranges for any room size. SLZ Series
Boasting low electricity consumption,
lightweight units sit in your ceiling space with only the grille visible, providing
SLZ/SEZ series air conditioners are the
discrete comfort. Meanwhile SEZ Series units are a slim 200mm in height,
key to fresh, cost-effective comfort.
making them ideal for tight installation spaces.
SLZ-KA25/50
Air Cleaning Filter
This built-in filter removes dust and
SEZ-KD35/50/60/71
990mm
other particles, keeping the air clean at
all times. Maintenance is as simple as
700mm
vacuuming. The long-life filter in SLZ/
208mm
SEZ Series indoor units can be used
200mm
for approximately 2,500 hours before
650mm
requiring replacement.
650mm
Fresh-Air Intake (SLZ Series)
A duct hole is provided in the main
Impressively Quiet
body, making it possible to intake fresh
S Series units offer quiet operation at a hushed noise level of 23dBA
air from outside.
(SEZ-KD35), ensuring a calm and comfortable environment. They’re so quiet
that you’ll find yourself checking to see if they’re on.
Noise Level Comparison
Rustling
leaves
Breathing
0dBA
Library
interior
20dBA
Average
street traffic
Dishwasher
40dBA
60dBA
Subway
car interior
80dBA
23dBA - Quiet!
Specifications: 4-way cassette / Compact ceiling-concealed (SLZ, SEZ)
Indoor unit
SLZ-KA25VAQ
SLZ-KA50VAQ
SEZ-KD35VAQ
SEZ-KD50VAQ
SEZ-KD60VAQ
SEZ-KD71VAQ
Outdoor unit
SUZ-KA25VA3
SUZ-KA50VAD
SUZ-KA35VAD
SUZ-KA50VAD
SUZ-KA60VAD
SUZ-KA71VAD
Cooling
Function
Cooling
Heating
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Capacity (min.-max.)
(kW ) 2.3 (0.9-3.2) 3.1 (0.9-4.5) 4.2 (1.1-5.2) 4.5 (0.9-6.5) 3.7 (1.0-3.9) 4.2 (0.9-5.0) 5.1 (1.1-5.6) 6.4 (1.1-7.2) 5.6 (1.1-6.3) 7.4 (0.9-8.0) 6.5 (0.9-8.3) 8.1 (0.9-10.4)
Input
(kW )
0.6
0.82
1.27
1.37
1.09
1.13
1.64
1.81
1.77
2.05
2.06
2.18
Rated EER/COP
3.81
3.94
3.35
3.31
3.39
3.72
3.17
3.54
3.28
3.55
3.28
3.69
Rated AEER/ACOP
3.64
3.81
3.28
3.25
3.31
3.63
3.11
3.49
3.22
3.50
3.23
3.64
AEER/ACOP (part-load %) *
4.32
3.72
SLZ-KA25VAQ
Indoor unit
SLZ-KA50VAQ
SEZ-KD35VAQ
SEZ-KD50VAQ
SEZ-KD60VAQ
SEZ-KD71VAQ
V: Single-phase, 50Hz, 230V
Power supply
CMM
8-9-10
8-9-11
7-9-11
10-12.5-15
12-15-18
12-16-20
L/S
133-150-167
133-150-183
117-150-183
167-208-250
200-250-300
200-267-333
Sound pressure level
(dB)
28-31-37
30-34-39
23-28-33
Supply air spigot size
(mm)
Height
(mm)
Unit: 235, Panel: 20
200
200
Width
(mm)
Unit: 570, Panel: 650
990
1,190
Depth
(mm)
Unit: 570, Panel: 650
(kg)
Unit: 17, Panel: 3
Airflow (Lo-Mid-Hi)
External static pressure Pa
Dimensions
Weight
5/15/35/50
—
30-34-37
860×150
—
30-35-40
1,060×150
700
21
30-34-38
700
23
27
* MEPS compliant at part load
18
Main Features of Mr. Slim Inverter Units
Indoor unit
SLZ-VAQ SLZ-VAL SEZ-VA
PLA
PEAD
PEA
PKA
PCA-KA
Combination
Outdoor unit
Energy
Saving
Air Quality
Air
Distribution
SUZ
SUZ
SUZ
PUHZ
SUZ
PUHZ
SUZ
PUHZ
PUHZ
PUHZ
SUZ
Felt Temperature Control
(i-See Sensor)
–
–
–
Opt
Opt
–
–
–
–
–
–
Fresh-Air Intake
•
•
–
•
•
–
–
–
–
•
•
High-Efficiency Filter
–
–
–
Opt
Opt
–
–
–
–
Opt
Opt
Oil Mist Filter
–
–
–
–
–
–
–
–
–
–
–
Long-Life Filter
•
•
–
•
•
•
•
–
–
•
•
Filter Check Signal
•
–
–
•
•
•
•
–
Opt
•
•
Auto Vane
•
•
–
•
•
–
–
–
•
•
•
Horizontal Vane (Auto Swing)
•
•
–
•
•
–
–
–
•
•
•
High Ceiling Mode
–
–
–
•
•
–
–
–
–
•
•
Auto Fan Speed Mode
–
–
•
•
•
–
–
–
•
•
•
On/Off Operation Timer
•
•
•
•
•
•
•
•
•
•
•
Auto Change Over *1
•
•
•
•
•
•
•
•
•
•
•
Auto Restart
•
•
•
•
•
•
•
•
•
•
•
Low-Temperature Cooling
•
•
•
•
•
•
•
•
•
•
•
Low-Noise Operation
(Outdoor Unit)
–
–
–
•
–
•
–
•
•
•
–
Rotation, Back-up and 2nd
Stage Cut-in Function
–
–
–
•
–
•
–
–
Opt
•
–
Opt
•
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Wi-Fi Control
–
–
Opt
–
–
Opt
Opt
Opt
–
–
–
PAR-32MAA Control *2
•
Opt
•
Opt
Opt
Opt
Opt
Opt
Opt
•
•
Centralised On/Off Control *2
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
System Group Control *2
Opt
Opt
Opt
•
Opt
•
Opt
•
Opt
•
Opt
M-NET Connection *2
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Opt
Reuse of Existing Wiring
–
–
–
Opt
–
Opt
–
–
Opt
Opt
–
Drain Pump
•
•
Opt
•
•
–
–
–
–
Opt
Opt
Pump Down Switch
–
–
–
•
–
•
–
•
•
•
–
Flare Connection
•
•
•
•
•
•
•
•*3
•
•
•
Self-Diagnosis Function
(Check Code Display)
•
•
•
•
•
•
•
•
•
•
•
Failure Recall Function
•
•
•
•
•
•
•
•
•
•
•
Convenience
Wireless Controller
System
Control
Installation
Maintenance
*1 When multiple indoor units connected to an MXZ outdoor unit are running at the same time, simultaneous cooling and heating is not possible
*2 Please refer “System Control” on page 20 for details
*3 Not available with PEA-RP170WJA models
19
System Controls
MAJOR SYSTEM CONTROL
System Examples
Indoor Unit
S Series & P Series Indoor Unit
P Series Indoor Unit
S Series Outdoor
P Series Outdoor
Outdoor Unit
A
Details
PAR-32MAA Control
Standard equipment SLZ-VAQ, SEZ-VAQ,
PCA-KAQ
PAR-32 can be hardwired to MA Terminal Block
(compatible models) to allow MAC-559IF-E
connection via CN105.
Wi-Fi Control
ADVANCED
MAC-559IF-E
PAR-32MAA
(Example of 1 : 1 system)
MAC-559IF-E
PAR-32MAA
(Example of Simultaneous Twin)
OPTIONAL UPGRADE
C
System Group Control
MAC-397IF-E
MAC-333IF-E
PAR-32MAA
PAR-32MAA
D
M-NET Connections
Outdoor
unit
Outdoor
unit
Indoor unit
Indoor
unit
Indoor unit
City Multi
indoor unit
PAR-32MAA
Indoor
unit
PAR-32MAA
MELANS
system controller
(AE-200A etc)
MELANS
system controller
(AE-200A etc)
• PAR-32MAA
• MAC-559IF-E
Twin pack connection:
1 x PAR-32 + 1 x MAC-559IF-E connected to
master indoor unit, secondary indoor follows
suit.
• One remote controller can control multiple air
conditioners with the same settings
simultaneously
• One remote controller can control up to 16
refrigerant systems
• Up to two remote controllers can be connected
<S Series Outdoor Unit>
• MAC-397IF-E/MAC-333IF-E (Interface)
• PAR-32MAA (Wired remote controller)
• Group of air conditioners can be controlled
by MELANS system controller (M-NET)
<S Series Outdoor Unit>
• MAC-399IF-E/MAC-333IF-E
• MELANS System controller
<P Series Outdoor Unit>
• PAR-32MAA (Wired remote controller)
<P Series Outdoor Unit>
• PAC-SF83MA-E (M-NET converter)
• MELANS System controller
PAR-32MAA
PAR-32MAA
MAC-399IF-E
MAC-333IF-E
• PAR-32MAA (Wired remote controller)
Optional equipment
SLZ-VAL, PLA, PEAD, PEA, PKA
PAR-32MAA
B
Major Optional Parts Required
M-NET adapter
PAC-SF83MA-E
FOR P SERIES AND S SERIES INDOOR UNITS
System Examples
Wired remote controller
A
Wireless remote controller
2-remote Controller
Control
• Up to two remote controllers can be
connected to one group
With two remote controllers, control
can be performed locally and remotely
from two locations.
PAR-SL97A-E
PAR-32MAA
PAR-32MAA
* Set "Main" and "Sub"
remote controllers.
(Example of 1 : 1 system)
B
Remote
control
panel
Wired remote
controller
Operation Control by
Pulse Signal
Remote Display of
Operating Status
Adapter for
remote
On/Off
Remote
control
panel
Wired remote
controller
Remote operation adapter/
Connector cable for remote display +
Relay box
PAR-32
MAA
(Example of 1 : 1 system)
E
Timer Operation
Allows On/Off operation with
timer
*For control by an external timer,
refer to B Operation Control
by Level Signal.
20
PAR-32MAA
(Example of 1 : 1 system)
• Operation other than On/Off (e.g. adjustment
of temperature, fan speed, and airflow) can be
performed even when remote controller
operation is prohibited
• Timer control is possible with an external timer
• Adapter for remote On/Off PAC-SE55RA-E
• Relay box (to be purchased locally)
• Remote control panel (to be purchased
locally)
• The pulse signal can be turned On/Off
• Operation/emergency signal can be received
at a remote location
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
(10 pcs. x PAC-SA88HA-E)
• Relay box (to be purchased locally)
• Remote control panel (to be purchased
locally)
• Operation/emergency signal can be received
at a remote location (when channelled
through the PAC-SF40RM-E
no-voltage signal, when channelled through
the PAC-SA88HA-E DC 12V signal)
• Remote display panel (to be purchased
locally)
• Connector cable for remote display
PAC-SA88HA-E / PAC-725AD
• Relay box (to be purchased locally)
• Remote operation adapter
PAC-SF40RM-E
PAR-SL97A-E
Relay box (to be purchased locally)
Connector
cable for
remote
display
Remote
control
panel
PAR-SL97A-E
(Example of 1 : 1 system x 2)
Remote operation adapter/
Connector cable for remote display +
Relay box
Operating status can be
displayed at a remote location.
Remote
display
panel
• Wired Remote Controller
PAR-32MAA
(for PKA, PAC-SH29TC-E is required)
• Wireless Remote Controller
PAR-SL97A-E (for SEZ and PEAD)
• Wireless Remote Controller Kit for PCA
PAR-SL94B-E
(Example of 1 : 1 system x 2)
Connector
cable for
remote display
(Example of 1 : 1 system x 2)
D
Relay box (to be purchased locally)
Relay box (to be purchased locally)
Remote
control
panel
• Both wired and wireless remote controllers
can be used in combination
Major Optional Parts Required
(Example of Simultaneous Twin)
Adapter for
remote
On/Off
(Example of 1 : 1 system x 2)
C
* When using wired and wireless
remote controllers
Relay box (to be purchased locally)
Operation Control by
Level Signal
Air conditioner can be started/
stopped remotely. In addition,
On/Off operation by local remote
controller can be prohibited/permitted.
Details
Remote
display
panel
*Unable to use with wireless remote controller
PAR-SL97A-E
(Example of Simultaneous Twin)
• Weekly Timer:
On/Off and up to 8 pattern temperatures can be
set for each calendar day (Initial setting)
• On/Off Timer:
On/Off can be set once each within 72 hr in
intervals of 5 minute units
• Auto-off Timer:
Operation will be switched off after a certain
amount of time has elapsed. Set time can be
changed from 30 min. to 4 hr. at 10 min.
intervals
*Simple Timer and Auto-off Timer
cannot be used at the same time
Standard functions of PAR-32MAA
Specifications
Specification: Outdoor Unit
Outdoor unit
SUZ-KA25VA
SUZ-KA35VA
SUZ-KA50VA
External finish
Munsell 3.0Y 7.8/1.1
Power supply
Single-phase, 50Hz, 230V
(kW)
0.65
0.9
0.9
1.2
34 (572)/32 (538)
33 (557)
49 (817)
51 (850)/49 (816)
50 (835)/48 (800)
Cooling mode
46
47
53
55
Heating mode
46
48
55
55
59
61
68
69
Airflow (cooling/heating)
CMM (L /S)
(dB)
Sound power level
Dimensions
SUZ-KA71VA
0.55
Compressor output
Sound pressure
level (dB)
SUZ-KA60VA
Height
(mm)
550
850
880
Width
(mm)
800
840
840
Depth
(mm)
285
330
330
Weight
(kg)
Chargeless piping length
(m)
Max. piping length
(m)
20
30
Breaker size
(A)
10
20
30
33
50
53
53
7
*Above specifications are for outdoor units only
Outdoor unit
PUHZ-RP71VHA
PUHZ-RP100VKA
PUHZ-RP125VKA
External finish
Munsell 3.0Y 7.8/1.1
Power supply
V: Single-phase, 50Hz, 230V
(kW)
Compressor output
PUHZ-RP140VKA
PUHZ-RP170VKA
2.9
3.0
1.6
1.9
55 (916)
110 (1,833)
Cooling mode
47
49
50
50
58
Silent mode
44
46
47
47
56
Heating mode
48
51
52
52
59
(dB)
66
69
70
70
76
Height
(mm)
943
1,338
Width
(mm)
950
1,050
Depth
(mm)
330
330
Weight
(kg)
67
120
127
Chargeless piping length
(m)
30
30
Max. piping length
(m)
50
75
17.17/19.23
19.40/23.90
Airflow (cooling/heating)
Sound pressure
level (dB)
Sound power level
Dimensions
CMM (L /S)
2.4
120 (2,000)
118
Protection device
140 (2,330)
Discharge thermo, HP switch
Rated running current
(cooling/heating)
(A)
9.05/9.64
Breaker size
(A)
25
12.64/13.58
16.36/16.90
32
40
*Above specifications are for outdoor units only
21
Specifications
Note for All Specifications
Rating conditions (AS/NZS 3823)
Total input based on the indicated voltage (indoor/outdoor)
Rating conditions (AS/NZS 3823)
Cooling - Indoor: 27°C (80°F) DB, 19°C (66°F) WB
Cooling - Outdoor: 35°C (95°F) DB
Heating - Indoor: 20°C (68°F) DB
Heating - Outdoor: 7°C (45°F) DB, 6°C (43°F) WB
50Hz
Refrigerant piping length (one-way): 5m (16ft.)
Indoor
Indoor
50Hz
Single-phase, 230V
Single-phase, 230V
SUZ-KA
SUZ-KA
25/35
Upper limit (DB)
Upper limit (DB)
Cooling
Lower limit (DB)
Heating
Upper limit (DB)
Heating
Single-phase, 230V
Single-phase, 230V
Guaranteed Operating Range
Cooling
Outdoor
Outdoor
Lower limit (DB)
Upper limit (DB)
Lower limit (DB)
Lower limit (DB)
25/35
46°C
–10°C
24°C
50/60/71
50/60/71
46°C
PUHZ
43°C
–10°C
–15°C
24°C
24°C
–10°C
–10°C
PUHZ
71/100/125/140/170
71/100/125/140/170
43°C
–15°C
24°C
–10°C
–10°C
46°C
46°C
–5°C (–15°C )
–5°C (–15°C )
21°C
21°C
–20°C
–20°C
*With the optional air protection guide, the operation at –15°C outdoor temperature is possible.
Sound Pressure Level
•Sound pressure measurements were conducted in an anechoic chamber
•The actual noise level depends on the distance from the unit and the acoustic environment
Amount of Necessary Refrigerant
Amount of Necessary Refrigerant (R410A: kg)
Factory charged
Additional charged
Calculation
Piping length
7m
10m
15m
20m
25m
30m
SUZ-KA25
0.8
0.15
0.3
0.45
—
—
SUZ-KA35
1.05
0.15
0.3
0.45
—
—
SUZ-KA50
1.6
0.06
0.16
0.26
0.36
0.46
SUZ-KA60
1.8
0.06
0.16
0.26
0.36
0.46
SUZ-KA71
1.8
0.165
0.44
0.715
0.99
1.265
Xg = 30g/m × (length-5) m
Xg = 20g/m × (length-7) m
Factory charged
Xg = 55g/m × (length-7) m
Additional charged
Piping length
10 - 30m
31 - 40m
41 - 50m
51 - 60m
61 - 75m
PUHZ-RP71
3.5
0.6
1.2
—
—
PUHZ-RP100/125/140
5.5
0.6
1.2
1.8
2.4
61 - 75m
Factory charged
Additional charged
Piping length
PUHZ-RP170
22
10 - 30m
31 - 40m
41 - 50m
51 - 60m
7.7
0.9
1.8
2.7
3.6
Optional Parts
Optional Parts
Part name
Air discharge guide
Air outlet shutter plate
Air protection guide
Control/service tool
Centralised drain pan
Drain pump
Model name
Application name
PAC-SG59SG-E
PUHZ-RP71
PAC-SH96SG-E
PUHZ-RP100/125/140
PAC-SH51SP-E
PLA-RP
PAC-SH63AG-E
PUHZ-RP71
PAC-SH95AG-E
PUHZ-RP100/125/140
PAC-SK52ST
PLA-RP
PEAD-RP71
PAC-KE94TB-E
PEAD-RP100/125
PAC-KE95TB-E
PEAD-RP140
i-See Sensor corner panel
PAC-SA1ME-E
PLA-RP
PUHZ-RP71/100/125/140
Shutter plate
PAC-SH51SP-E
PLA-RP
PAC-SG64DP-E
PUHZ-RP71
Joint pipe
PAC-SH97DP-E
PUHZ-RP100/125/140
PAC-SG73RJ-E
PAC-SG75RJ-E
PUHZ-RP71/100/125/140
PUHZ-RP71/100/125/140
PAC-SH83DM-E
PCA-RP50KAQ
M-NET converter
PAC-SF83MA-E
PUHZ-RP71/100/125/140
Multi-function casement
PAC-SH53TM-E
PLA-RP
PAC-SG94HR-E
PKA-RP
PAC-SG96HR-E
PCA-RP50/60/71/100/125/140KAQ
PAC-SG97HR-E
PEAD-RP
PAC-SH84DM-E
High efficiency filter element
Filter box
PCA-RP71/100/125/140KAQ
SEZ-KD
Power supply terminal kit
PAC-SG61DS-E
PUHZ-RP71/100/125/140
Flange for fresh-air intake
PAC-SH65OF-E
PLA-RP
PAC-SH52HR-E
PLA-RP
Remote On/Off adaptor
PAC-SE55RA-E
All indoor units
Remote operation adaptor
PAC-SF40RM-E
All indoor units*2 (excluding PKA-RP)
Remote sensor
PAC-SE41TS-E
All indoor units
Space panel
PAC-SH48AS-E
PLA-RP
SLZ-KA, SEZ-KD, PLA-RP60/71*1
PEAD-RP71*1, PCA-RP50/60/71*1
Terminal block
PAC-SH29TC-E
PKA-RP for wired remote controller
Connector cable
for remote display
PAC-SA88HA-E
All indoor units
Wired remote controller
PAR-32MAA
All indoor units
(excluding SLZ-VAL)
PLA-RP60/71*1
MAC-397IF-E
SLZ-KA, SEZ-KD,
PEAD-RP71*1, PCA-RP50/60/71*1
MAC-399IF-E
SLZ-KA, SEZ-KD, PLA-RP60/71*1
PEAD-RP71*1, PCA-RP50/60/71*1
MAC-333IF-E
9.52 12.7
15.88 19.05
PCA-RP60KAQ
Drain socket
M-NET &Terminal interface
Application name
PAC-KE93TB-E
PAC-KE07DM-E
M-NET interface
Model name
PAC-SH59KF-E
PAC-SH85DM-E
MA & Contact terminal interface
Part name
Wireless remote controller
PAR-FL32MA-E
PEAD-RP
Wireless remote controller
signal sender
PAR-SL97A-E
SEZ-KD, PLA-RP
PAR-SA9CA-E
SEZ-KD, PEAD-RP
PAR-SA9FA-E
PLA-RP
Wireless remote controller kit
(Sender & Receiver)
PAR-SL94B-E
PCA-RP
PAC-SH88KF-E
PCA-RP50KAQ
Power supply unit
PAC-SC51KUA
All outdoor units
PAC-SH89KF-E
PCA-RP60/71KAQ
All indoor units
PCA-RP100/125/140KAQ
Multiple remote controller
adaptor
PAC-725AD
PAC-SH90KF-E
Wi-Fi Adaptor
MAC-559IF-E
All PEA/PEAD/SEZ indoor units
Wireless remote controller
signal receiver
High efficiency filter
*1 P series indoor units can be used in combination with SUZ outdoor units
*2 Unable to use with wireless remote controller
Refrigerant Piping
Capacity
SUZ-KA25
SUZ-KA35
SUZ-KA50
SUZ-KA60
SUZ-KA71
PUHZ-RP71
PUHZ-RP100/125/140
PUHZ-RP170
Between indoor & outdoor units
Max. height difference (m)
Max. piping length (m)
12
20
12
30
30
30
30
30
30
20
30
30
30
50
75
75
Pipe size OD (mm)
Thickness (mm)
Liquid: ø6.35
t 0.8
Gas:
ø9.52
t 0.8
Liquid: ø6.35
t 0.8
Gas:
ø9.52
t 0.8
Liquid: ø6.35
t 0.8
Gas:
ø12.7
t 0.8
Liquid: ø6.35
t 0.8
Gas: ø15.88
t 1.0
Liquid: ø9.52
t 0.8
Gas: ø15.88
t 1.0
Liquid: ø9.52
t 0.8
Gas: ø15.88
t 1.0
Liquid: ø9.52
t 0.8
Gas: ø15.88
t 1.0
Liquid: ø9.52
t 0.8
Gas:
t 1.0
ø25.4
23
NOTICE
•Air conditioners in this brochure contain and operate with refrigerant R410A and synthetic oils.
•Before attempting any installation work you must read the installation instructions.
•New tools, materials and procedures are required to install these products.
•By law, only persons suitably licensed are permitted to install and service air conditioning units.
•Refer to Country, Commonwealth, State or Territory legislation, regulations and industry codes of practice, before
installation of these products.
•Recovery and disposal of waste material must comply with Country, Commonwealth, State or Territory guidelines.
•Do not install indoor units in areas where the emission of VOCs such as phthalate compounds and formaldehyde is
known to be high (e.g. mobile phone base stations) as this may result in a chemical reaction.
•When installing, relocating or servicing the air conditioners, use only the specified refrigerant (R410A) to charge the
refrigerant lines.
•Do not mix it with any other refrigerant and do not allow air to remain in the lines.
•If air is mixed with the refrigerant, then it can be the cause of abnormal high pressure in the refrigerant lines, and
may result in an explosion and other hazards.
•The use of any refrigerant other than that specified for the system will cause mechanical failure, system malfunction
or unit breakdown. In the worst case, this could lead to a serious impediment to securing product safety.
For more information on Mitsubishi Electric Heat Pumps, please call our customer service team on 0800 784 382
www.mitsubishi-electric.co.nz
Black Diamond Technologies
Exclusive distributor of Mitsubishi
Electric products in New Zealand.
WELLINGTON
AUCKLAND
CHRISTCHURCH
HEAD OFFICE
BRANCH
BRANCH
1 Parliament Street
Unit 1, 4 Walls Road
44 Halwyn Drive
PO Box 30772
PO Box 12726
PO Box 16904
Lower Hutt 5040
Penrose, Auckland 1642
Hornby, Christchurch 8441
Phone (04) 560 9147
Phone (09) 526 9347
Phone (03) 341 2837
Fax (04) 560 9133
Fax (09) 526 9369
Fax (03) 341 2838
Be sure to ask for Mitsubishi Electric. Other brands share the 3-diamond logo, however are separate to the Mitsubishi Electric brand and cannot supply the
models, features or guarantees outlined in this brochure. | All models, features and specifications are subject to change and amendment at anytime. May 2017
24