Liebherr commercial appliances can be found at specialist retailers

Liebherr commercial appliances can be found at specialist retailers
Liebherr commercial appliances can be found at
specialist retailers where providing first-class service
and expert advice is their top priority.
Refrigerators and freezers
Research and laboratory
2015 / 2016
Refrigerators and freezers
Horeca
Freezers for the frozen food
and ice-cream industries
Refrigerators and freezers
Bakery
Wine
Special
Refrigerators
Drinks industry
Refrigerators and freezers
General purpose
Refrigerators
Pharmacy
Island merchandiser
Food retail
Smart communication on all fronts
Media App
WineGuide App
Download all catalogues and videos to your tablet
quickly and easily for instant offl ine access.
A brief overview of Bordeaux wines and their
producers, plus storage information.
Find out which app
is available for which
operating system
(Apple, Android etc.),
and which device type.
apps.home.liebherr.com
The Liebherr-Hausgeräte YouTube channel provides
interesting and helpful fi lms showing you the functions
of Liebherr refrigerators and freezers.
News, product launches and special promotions can
be found on our Facebook page, the Liebherr blog
and Twitter.
Learn all about our
current social media
channels
socialmedia.home.
liebherr.com
www.liebherr.com
40
Subject to alterations. Printed in Germany by
raff mediagroup. 7944257-00/7.385/05.2015
You can find an overview of all Liebherr appliances in our main catalogues. Available in stores or on www.liebherr.com.
Liebherr laboratory refrigerators
and freezers
Refrigerators and freezers for use in the laboratory and in research
have to meet very stringent requirements, especially with regard
to safety and temperature consistency. Liebherr appliances are
therefore equipped with many functions and features to ensure
optimum storage of sensitive samples, critical chemicals and
research materials. The precision electronic controller enables
accurate temperature setting and creates optimum storage
conditions in conjunction with highly effective insulation and
the dynamic cooling system. Integrated visual and audible
alarm systems warn the user of undesired temperature deviations.
Liebherr refrigerators and freezers provide the safety that is
essential in the laboratory and research sector – 24 hours a day,
365 days a year.
Contents
02
Laboratory refrigerators and freezers
with Profi electronic controller
06
Laboratory refrigerators and freezers
with Comfort electronic controller and spark-free interior
12
Laboratory refrigerators and laboratory fridge-freezer
with Comfort electronic controller
18
Laboratory chest freezers up to - 45°C
24
Laboratory refrigerators with
analogue controls and spark-free interior
30
Accessories
34
03
Good reasons
to choose Liebherr
Highest performance
Efficiency
Reliability
Easy cleaning
Safety
Easy servicing
Liebherr research and laboratory freezers
provide constant refrigeration performance
even in extreme climate conditions. The
use of ultra-modern components, efficient
and environmentally-friendly refrigerants
as well as precision controls ensures that
samples, chemicals and research materials
are stored optimally. Optional documentation
software continuously logs the temperature
profile – and if required, warning systems
alert the user when defined temperature
limits are exceeded.
Highly efficient with low energy consumption:
the precision electronic controller, the
dynamic refrigeration system and highly
effective insulation guarantee low operating
costs and are eco-friendly as well. The
high quality of the appliances guarantees
long life and reliable operation and
provides for economic and ecological
sustainability in laboratory and research
applications.
All laboratory appliances are designed
according to the ISO 60068-3 standard
with regard to maximum temperature
stability. They are specially constructed
for intensive professional use and feature
a very sturdy design – with highest-quality
materials and perfect workmanship right
down to the smallest detail. The exemplary
quality of the appliances is ensured by
elaborate tests. All electronic and
refrigeration components fulfill Liebherr's
stringent specifications to form a wellbalanced and therefore reliable system –
ideal for research and laboratory.
Hygiene plays a special role in research
and in the laboratory. That is why Liebherr
appliances are equipped with moulded
inner liners with large radii that are easy
to clean. Flush seals prevent condensation
and the accumulation of dirt and dust.
Sturdy castors also allow easy cleaning
of the floor space underneath the
appliances.
To meet the most stringent requirements
regarding reliability and accurate
temperature consistency in laboratory
applications, Liebherr appliances are
equipped with many useful features:
a visual and audible door alarm alerts
the user to undesired temperature
deviations. The appliances can be
connected via the volt-free contact to an
external remote warning system – and up
to 20 appliances can be networked with
a monitoring and alarm system via the
serial interface RS 485. In case of a
power failure, the Profi electronic
controller (in LKPv and LGPv) is powered
by a battery for 72 hours to prevent data
loss. The calibration option allows
precise temperature control adapted to
specific applications.
Durability and reliability are given top
priority in the material selection and
development of Liebherr laboratory
appliances. The exemplary quality and
easy usability of the appliances are
ensured by elaborate tests. In appliances
with a Profi electronic controller, the
refrigeration components are integrated
in the ceiling area, allowing easy access.
The practical door remains open at 90°
and is self-closing at less than 60° for
convenient use. And the sturdy inner
liners are easy to clean and allow
variable adjustment of the grid shelves.
04
05
Laboratory refrigerators and freezers with Profi electronic controller
The advantages at a glance
The refrigeration components are
securely integrated in the ceiling area,
allowing ready access.
The temperature can be set to
1/10 °C accuracy via the menu-guided,
multilingual Profi electronic controller
with integrated real-time clock.
The Profi electronic controller
has an integrated data memory for
temperature recording.
After a refrigerator or freezer door has been opened, a vacuum is built
up by air exchange – with the effect that the door is hard to reopen
immediately afterwards. The integrated pressure relief valve ensures
that the vacuum is quickly equalised so that the door can easily be reopened.
The laboratory appliances with a Profi electronic controller are equipped
with a volt-free contact for alarm forwarding to an external warning system.
Laboratory appliances with a
Profi electronic controller are
equipped with an access port
(7.0 mm in diameter) in the ceiling
area to enable connection of an
independent temperature sensor.
Maximum temperature stability in the interior is ensured by the dynamic cooling
system with double ventilation, in conjunction with optimal routing of the air flow.
Visual and audible door alarms alert
the user if the door is open for
longer than 1 minute.
In case of power failure, the electronic controller is immediately powered by an
integrated 12 V battery. As a result, the integrated memory continues to log
the internal temperatures without interruption for another 72 hours.
The smooth interior made
of 304-grade stainless steel
is easy to clean and enables
optimum hygiene.
The hot-gas defrost system with demand and time control permits very short
defrost cycles: 8 minutes for laboratory refrigerators, 12 minutes for laboratory
freezers. To additionally improve temperature stability during defrost, the internal
temperature is lowered by 1 °C (refrigerators) or 2 °C (freezers) shortly before.
In laboratory appliances with a Profi electronic controller, 3-point
calibration enables temperature control adapted to the user.
To increase the net capacity of the inner liner, functional parts like fans and
evaporators are located outside the refrigerator compartment to save space.
The practical door remains open at 90 °
and is self-closing at less than 60 ° for
convenient use.
The LKPv and LGPv ranges come with
castors as standard to allow versatile
use depending on the available space
and convenient cleaning also underneath
the appliances.
LKPv 6520
06
07
Laboratory refrigerators and freezers with Profi electronic controller
Quality right down to the smallest detail
The MediLine range appliances with a Profi electronic controller are equipped with many features to guarantee the safety of
stored products and temperature stability in the interior. High-quality materials and precise workmanship, extremely efficient
refrigeration components as well as documentation and alarm functions ensure optimum storage of sensitive samples, chemicals
and research materials.
+0.8°C
72
hours
-0.4°C
+0.5°C
Integrated alarm systems.
A visual and audible door alarm alerts the user to temperature
deviations. An alarm is also raised if the door is open for longer
than one minute or in the event of power failure.
The Profi electronic controller.
The menu-guided, multilingual Profi electronic controller with
integrated real-time clock allows the temperature to be set
to 1/10 °C accuracy. The membrane keyboard is dirt resistant
and easy to clean – to meet the most stringent hygiene
requirements in the laboratory.
Integrated data memory.
The Profi electronic controller is equipped with data memory
which records the last 30 alarm events together with the date,
time and maximum temperature. In addition, the internal
temperature is logged in 4-minute intervals. The last
2,800 temperature logs are respectively available, which
corresponds approximately to a 1-week logging period.
Cal.1 1.0°C 0.5°C Cal.2 8.0°C -0.4°C Cal.3 15.0°C 0.8°C
Precision with 3-point calibration.
The laboratory appliances with a Profi electronic controller
have a 3-point calibration function for extremely accurate
temperature control. This permits compensation between the set
temperature and the actual internal temperature at as many
as three temperature points. Positive or negative changes to
the correction value can be made in steps of 0.1 K.
Mains-independent power supply of the electronic controller.
In case of power failure, the electronic controller is powered
by a battery. As a result, the memory continues to log the
internal temperatures without interruption for another 72 hours.
If external alarm and monitoring systems have been
connected, then data transfer to these is also maintained.
External temperature sensor.
The laboratory appliances have an access port (diameter
7.0 mm) in the appliance ceiling which allows a temperature
sensor to be positioned in the interior.
Advantage of hot gas defrost
It is quick, with minimal temperature rise.
30 min
Electric defrost
External temperature and alarm documentation.
The laboratory appliances with a Profi electronic controller are
equipped with a volt-free contact for alarm forwarding to an
external remote warning system. The data can be read out of
the internal memory and transferred to a PC via an infrared
interface. In addition the appliances have an RS 485 interface
which enables as many as 20 appliances to be networked with
a central monitoring and alarm system.
08
Maximum temperature consistency.
Maximum temperature stability in the interior is ensured by the
dynamic cooling system with double ventilation. Very short
defrost cycles allow the internal temperature to be kept almost
constant during the defrost phases. All laboratory appliances
are designed according to the ISO 60068-3 standard with
regard to maximum temperature stability and consistency.
10 min
Hot gas defrost
Energy-efficient hot-gas defrost system.
Defrost less often and faster: the controller calculates the
optimum defrost cycles based on the compressor run-time.
Then the refrigerators defrost in just 8 minutes and the
freezers in just 12 minutes. The internal temperature is
slightly lowered shortly before so it remains almost constant
during the defrost cycle.
Versatile interior.
Sturdy and versatile: the U-shaped trayslides are heightadjustable – so refrigerated or frozen products of any kind can
be stored optimally on the plastic-coated grid shelves.
Hygienic benefit: the interior made of high-quality 304-grade
stainless steel is easy to clean thanks to the large corner radii.
09
Laboratory refrigerators with Profi electronic controller
Laboratory freezers with Profi electronic controller
Laboratory refrigerators and
freezers with Profi electronic controller
LKPv 1423
LKPv 8420
LKPv 6523
LKPv 6520
LGPv 1420
LGPv 8420
LGPv 6520
MediLine
MediLine
MediLine
MediLine
MediLine
MediLine
MediLine
Gross capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system
Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Power failure alarm
Fault: warning signal
Interface / Volt-free alarm contact
Interior light
Adjustable shelves
Usable shelf area in mm (w / d)
Shelf material
Shelf loading
Castors
1427 litre
1430 / 830 / 2150
1250 / 700 / 1550
3.923 kWh
856 litre
790 / 980 / 2150
620 / 850 / 1550
2.400 kWh
601 litre
700 / 830 / 2150
520 / 700 / 1550
2.731 kWh
601 litre
700 / 830 / 2150
520 / 700 / 1550
1.775 kWh
1427 litre
1430 / 830 / 2150
1250 / 700 / 1550
8.887 kWh
856 litre
790 / 980 / 2150
620 / 850 / 1550
5.500 kWh
601 litre
700 / 830 / 2150
520 / 700 / 1550
4.715 kWh
forced-air
automatic
0°C to +16°C
steel / white
glass door
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
LED lighting, with separate switch
8
1250 / 650
wire shelves plastic-coated
60 kg
castors with brake at the front,
castors at the rear
full-length integrated handle
fitted
yes
forced-air
automatic
-2°C to +16°C
steel / white
steel
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
forced-air
automatic
-2°C to +16°C
steel / white
steel
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
forced-air
automatic
-10°C to -26°C
steel / white
steel
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
forced-air
automatic
-10°C to -35°C ¹)
steel / white
steel
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
forced-air
automatic
-10°C to -35°C ¹)
steel / white
steel
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
4
520 / 650
wire shelves plastic-coated
60 kg
castors with brake at the front,
fixed castors at the rear
full-length integrated handle
fitted
yes
right, reversible on site
158 / 132 kg
T (5)
58 dB(A)
R 290
220 – 240V~ / 2.0 A
8
1250 / 650
wire shelves plastic-coated
60 kg
castors with brake at the front,
castors at the rear
full-length integrated handle
fitted
yes
284 / 229 kg
T (5)
58 dB(A)
R 290
220 – 240V~ / 3.0 A
4
620 / 800
wire shelves plastic-coated
60 kg
castors with brake at the front,
fixed castors at the rear
full-length integrated handle
fitted
yes
right, reversible on site
187 / 154 kg
T (5)
58 dB(A)
R 290
220 – 240V~ / 2.0 A
forced-air
automatic
0°C to +16°C
steel / white
glass door
304-grade stainless steel
electronic controller with text display
external digital
immediately upon power failure for 72hrs
visual and audible
RS 485 / yes
LED lighting, with separate switch
4
520 / 650
wire shelves plastic-coated
60 kg
castors with brake at the front,
fixed castors at the rear
full-length integrated handle
fitted
yes
right, reversible on site
167 / 141 kg
T (5)
58 dB(A)
R 290
220 – 240V~ / 2.0 A
262 / 219 kg
T (5)
60 dB(A)
R 290
220 – 240V~ / 4.5 A
4
620 / 800
wire shelves plastic-coated
60 kg
castors with brake at the front,
fixed castors at the rear
full-length integrated handle
fitted
yes
right, reversible on site
197 / 164 kg
T (5)
60 dB(A)
R 290
220 – 240V~ / 4.0 A
4
520 / 650
wire shelves plastic-coated
60 kg
castors with brake at the front,
fixed castors at the rear
full-length integrated handle
fitted
yes
right, reversible on site
171 / 143 kg
T (5)
60 dB(A)
R 290
220 – 240V~ / 4.0 A
7112393
9001761
9001757
9590389
9590387
9590407
7113643
9005067
9005069
9590389
9590387
9590407
7112393
9001761
9001757
9590389
9590387
9590407
7112393
9001761
9001757
9590389
9590387
9590407
7112393
9001761
9001757
9590389
9590387
9590407
7113643
9005067
9005069
9590389
9590387
9590407
7112393
9001761
9001757
9590389
9590387
9590407
Handle
Lock
Self-closing door
Door hinges
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
Accessories
Shelf, plastic-coated
U-shaped trayslide, right
U-shaped trayslide, left
Infrared key incl. software
RS 485 / RS 232 adapter, data log software
NTC product temperature probe
Also available as
10
LKPv 1420 with solid doors
* measured at +25 °C ambient temperature and +5 °C set temperature for fridges and -20 °C for freezers
1) The temperature range is valid at a maximum ambient temperature of +30 °C
11
Laboratory refrigerators and freezers with Comfort electronic controller and spark-free interior
The advantages at a glance
The laboratory appliances with a Comfort
electronic controller are equipped with a
volt-free contact for alarm forwarding to
an external remote warning system.
The precision Comfort electronic controller with digital temperature display
allows accurate temperature setting to 1/10 °C.
All laboratory refrigerators and freezers with spark-free interior are tested
according to the 94/9 EC (ATEX 95) Directive.
Access port for integration of an independent
temperature sensor (e.g. an optionally available
NTC temperature sensor or similar measuring
instruments) in laboratory appliances with a
Comfort electronic controller.
The precision Comfort electronic controller has an integrated data
memory. It logs e.g. the maximum and minimum internal temperatures.
The commercial-grade moulded polystyrol
inner liner is exceptionally easy to clean and
enables optimum hygiene.
Laboratory appliances with a Comfort electronic controller provide 1-point
calibration for accurate temperature control. This permits compensation
between the set temperature and the actual internal temperature.
The glass shelves of the laboratory refrigerators
with spark-free interior are height adjustable
and can easily be removed at a door opening
angle of 90 °.
The self-closing door prevents unnecessary cold loss and contributes to
the temperature stability of the appliances. The integrated lock is very sturdy
and protects the samples and products against unauthorised access.
The drawers in the LCexv laboratory
fridge-freezer can easily be removed by the
handles recessed in the sides. The drawers
have a transparent front providing a clear
view of the products stored inside.
Door seals are replaceable.
LCexv 4010
12
13
Laboratory refrigerators and freezers with Comfort electronic controller and spark-free interior
Quality right down to the smallest detail
Liebherr offers refrigerators and freezers with a Comfort electronic controller and spark-free interior especially for storing explosive
and highly flammable substances in the chemical industry. The inner liners meet the safety requirements of the EU Directive 94/9 EG
(ATEX 95) and have been tested according to the EN 1127-1, IEC 60079-0 and IEC 60079-15 standards by electrosuisse – SEV
(Swiss Association for Electrical Engineering, Power and Information Technologies), an approved ATEX conformity evaluation organisation.
+0.5°C
Cal.
Certified according to ATEX 95.
All appliances with spark-free interior are tested according to
the 94/9 EC (ATEX 95) Directive. Rated as II 3G Ex nA II T6,
these appliances are suitable for storing explosive and highly
flammable substances in sealed containers.
Integrated alarm systems.
Visual and audible alarm systems alert the user to undesired
temperature deviations or when the door is open. All alarm
parameters can be individually set. For example, the dooropen alarm delay can be adjusted between 1 and 5 minutes.
Furthermore, the laboratory appliances with a Comfort
electronic controller have a visual power failure alarm and a
sensor defect alarm.
14
The Comfort electronic controller.
The precision Comfort electronic controller with digital
temperature display enables temperatures to be set accurately
to 1/10 °C. Symbols indicate the operating status of the
appliance. The electronic controller is flush-mounted and
equipped with a membrane keyboard for perfect hygiene.
Integrated data memory.
The Comfort electronic controller is equipped with an integrated
data memory which logs the maximum and minimum internal
temperatures as well as the last three temperature alarms
and power failures, together with the time, date and duration.
These data can be read out on the display.
5.0°C +0.5°C
Accurate 1-point calibration.
The laboratory appliances with a Comfort electronic controller
have a 1-point calibration function for accurate temperature
control. This permits compensation between the set temperature
and the actual internal temperature. Positive or negative changes
to the correction value can be made in steps of 0.1 K.
Maximum temperature consistency.
Maximum temperature stability is ensured by the cooling systems
of the laboratory refrigerators and freezers in conjunction with
the precision Comfort electronic controller. The refrigerators are
equipped with a safety thermostat to prevent temperatures
below +2 °C in case of a fault. All laboratory appliances with
a Comfort electronic controller are designed according to the
ISO 60068-3 standard with regard to maximum temperature
stability and consistency.
External temperature and alarm documentation.
The laboratory appliances are equipped with a volt-free
contact for alarm forwarding to an external remote warning
system, as well as with a serial interface RS 485 which
enables central documentation of temperature profiles and
alarm events. LTM monitoring software is optionally available.
Sturdy glass shelves.
The sturdy glass shelves are easily adjustable in height and can
conveniently be removed at a door opening angle of 90 °. They
ensure secure positioning of the refrigerated or frozen products
and have a loading capacity of up to 40 kg in the refrigerator
compartment and up to 24 kg in the freezer compartment.
External temperature sensor.
The laboratory appliances with a Comfort electronic controller
have an access port (diameter 10 mm) on the rear which
allows the temperature sensor to be positioned in the interior.
15
Laboratory fridge-freezer with Comfort electronic controller and spark-free interior
Laboratory fridge-freezer with Comfort electronic controller and
spark-free interior
LCexv 4010 MediLine
Total gross / net capacity
Total gross / net capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system
Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Power failure alarm
Fault: warning signal
Interface / Volt-free alarm contact
Adjustable shelves
Usable shelf area in mm (w / d)
Shelf material
Shelf loading
Drawers
Handle
Lock
Self-closing door
Door hinges
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
254 / 240 litre
107 / 105 litre
600 / 615 / 2000
440 / 435 / 1105
431 / 435 / 597
1.800 kWh
fridge compartment
freezer compartment
fridge compartment
freezer compartment
fridge / freezer comp.
fridge / freezer comp.
fridge / freezer comp.
fridge compartment
fridge compartment
fridge / freezer comp.
fridge / freezer comp.
freezer compartment
Accessories
Glass shelf
NTC product temperature probe
RS 485 / RS 232 adapter, data log software
Additional lock barrels (up to 10)
16
Laboratory refrigerators and
freezers with Comfort electronic
Laboratory refrigerators and freezers with Comfort electronic controller and spark-free interior
LKexv 3910 MediLine
LKUexv 1610 MediLine
LGex 3410 MediLine
LGUex 1500 MediLine
360 / 344 litre
600 / 615 / 1840
440 / 435 / 1635
0.865 kWh
141 / 130 litre
600 / 615 / 820
440 / 435 / 670
0.863 kWh
310 / 284 litre
600 / 615 / 1840
420 / 400 / 1587
1.309 kWh
139 / 129 litre
600 / 615 / 820
454 / 450 / 663
0.926 kWh
forced-air / automatic
+3°C to +16°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
5
440 / 420
glass
40 kg
forced-air / automatic
+3°C to +16°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
3
440 / 420
glass
40 kg
static / manual
-9°C to - 30°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
static / manual
-9°C to -26°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
ergonomic slimline handle
fitted
yes
right, reversible on site
74 / 68 kg
SN-ST
48 dB(A)
R 600a
220 – 240V~ / 1.5 A
ergonomic slimline handle
fitted
yes
right, reversible on site
41 / 39 kg
SN-ST
45 dB(A)
R 600a
220 – 240V~ / 1.0 A
evaporator plates
24 kg
8/–
185
ergonomic slimline handle
fitted
yes
right, reversible on site
92 / 87 kg
SN-ST
45 dB(A)
R 600a
220 – 240V~ / 1.5 A
evaporator plates
24 kg
3/1
149
ergonomic slimline handle
fitted
yes
right, reversible on site
45 / 42 kg
SN-ST
45 dB(A)
R 600a
220 – 240V~ / 1.0 A
9293629
9293629
9876687
9590521
9590523
controller and spark-free interior
forced-air / static
automatic / manual
+3°C to +16°C / -9°C to - 30°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
4
440 / 420
glass / glass
40 kg / 24 kg
3
ergonomic slimline handle
fitted
yes
right, reversible on site
93 / 87 kg
SN-ST
52 dB(A)
R 600a
220 – 240V~ / 1.5 A
9293629
9590145
9590387
on request
Total gross / net capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system / Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Power failure alarm
Fault: warning signal
Interface / Volt-free alarm contact
Adjustable shelves
Usable shelf area in mm (w / d)
Shelf material
Shelf loading
Drawers / Number of baskets
Compartment height in mm
Handle
Lock
Self-closing door
Door hinges
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
Accessories
Glass shelf
Stacking kit, white
Roller bars
Evaporator cover, white
Adjustable legs
NTC product temperature probe
RS 485 / RS 232 adapter, data log software
Additional lock barrels (up to 10)
9590525
9590233
9590145
9590387
on request
9590145
9590387
on request
* measured at +25 °C ambient temperature and +5 °C set temperature for fridges and -20 °C for freezers
9876687
9590521
9590233
9590145
9590387
on request
9590145
9590387
on request
17
Laboratory refrigerators and laboratory fridge-freezer with Comfort electronic controller
The advantages at a glance
Volt-free contact for forwarding alarms to an
external remote warning system in laboratory
appliances with a Comfort electronic controller.
The precision Comfort electronic controller with digital
temperature display allows accurate temperature setting to 1/10 °C.
An integrated data memory logs the last three temperature
alarms and power failures, together with the time, date and
duration of the alarm. The respective data can be recalled using
the AlarmLog function and read on the display panel.
The commercial-grade moulded polystyrol
inner liner is exceptionally easy to clean and
enables optimum hygiene.
Laboratory refrigerators LKv 3913 and LKUv 1613 with a glass door feature
an efficient LED interior light with a separate switch.
Laboratory appliances with a Comfort electronic controller provide 1-point calibration for
accurate temperature control. This permits compensation between the set temperature and
the actual internal temperature.
The sturdy, plastic-coated grid shelves have
a loading capacity of up to 45 kg, are easily
adjustable in height and can be removed at a
door opening angle of 90 °.
Self-closing doors prevent cold loss and contribute to the
temperature stability of the appliances. The integrated lock
is very sturdy and protects the samples and products against
unauthorised access.
Access port for integration of the optionally available NTC temperature sensor or
independent temperature sensor PT 100 or similar measuring instruments in
laboratory appliances with a Comfort electronic controller.
The drawers in the LCv 4010 laboratory
fridge-freezer can easily be removed by the
handles recessed in the sides. The drawers
have a transparent front providing a clear view
of the products stored inside.
The dynamic cooling system in conjunction with the precision Comfort electronic controller ensures
maximum temperature stability and high temperature consistency in the interior.
LKv 3913
18
19
Laboratory refrigerators and laboratory fridge-freezer with Comfort electronic controller
Quality right down to the smallest detail
Liebherr MediLine laboratory refrigerators the ideal solution for a small footprint or for under-worktop integration. The range
comprises two freestanding and under-worktop refrigerators with a glass door or a solid door. The precision Comfort electronic
The Comfort electronic controller.
The precision Comfort electronic controller with digital temperature
display enables temperatures to be set accurately. Symbols
indicate the operating status of the appliance. The electronic
controller is flush-mounted and equipped with a membrane
keyboard for perfect hygiene.
Integrated alarm systems.
Visual and audible alarm systems alert the user to undesired
temperature deviations or when the door is open. All alarm
parameters can be individually set. For example, the dooropen alarm delay can be adjusted between 1 and 5 minutes.
Additional safety is provided by a visual power failure alarm
and sensor defect alarm.
controller enables temperatures to be set accurately. The dynamic cooling system ensures high temperature consistency. Integrated
alarm systems guarantee safe storage.
External temperature and alarm documentation.
The laboratory appliances are equipped with a volt-free contact
for alarm forwarding to an external remote warning system,
as well as with a serial interface RS 485 which enables central
documentation of temperature profiles and alarm events. LTM
documentation software is optionally available.
Maximum temperature consistency.
The dynamic cooling system in conjunction with the precision
Comfort electronic controller ensures maximum temperature
stability. All laboratory appliances with a Comfort electronic
controller are designed according to the ISO 60068-3 standard
with regard to optimum temperature consistency.
+0.5°C
+ 2 ˚C
Cal.
5.0°C +0.5°C
Accurate 1-point calibration.
The laboratory appliances with a Comfort electronic controller
are equipped with 1-point calibration for accurate temperature
control. This permits compensation between the set temperature
and the actual internal temperature. Positive or negative
changes to the correction value can be made in steps of 0.1 K.
20
Integrated data memory.
The Comfort electronic controller is equipped with an integrated
data memory which logs the maximum and minimum internal
temperatures as well as the last three temperature alarms and
power failures, together with the time, date and duration. These
data can be read out on the display.
Safety thermostat.
The laboratory appliances are equipped with an additional
safety thermostat to prevent temperatures below +2 °C and
to protect sensitive products in the event of a fault.
External temperature sensor.
The laboratory appliances with a Comfort electronic controller
have an access port (diameter 10 mm) on the rear which allows
the temperature sensor to be positioned in the interior.
21
Laboratory refrigerators with Comfort electronic controller
Laboratory fridge-freezer with Comfort electronic controller
Laboratory refrigerators LKv 3913
LKv 3910
LKUv 1613
LKUv 1610
Laboratory fridge-freezer LCv 4010
with Comfort electronic controller
MediLine
MediLine
MediLine
MediLine
with Comfort electronic controller
MediLine
Total gross / net capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system
Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Power failure alarm
Fault: warning signal
Interface / Volt-free alarm contact
Interior light
Adjustable shelves
Usable shelf area in mm (w / d)
Shelf material
Shelf loading
Handle
Lock
Self-closing door
Door hinges
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
360 / 344 litre
600 / 615 / 1840
440 / 435 / 1635
1.315 kWh
360 / 344 litre
600 / 615 / 1840
440 / 435 / 1635
0.846 kWh
141 / 130 litre
600 / 615 / 820
440 / 435 / 670
1.010 kWh
141 / 130 litre
600 / 615 / 820
440 / 435 / 670
0.747 kWh
forced-air
automatic
+3°C to +16°C
steel / white
glass door
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
LED lighting, with separate switch
5
440 / 420
wire shelves plastic-coated
45 kg
ergonomic slimline handle
fitted
yes
right, reversible on site
90 / 84 kg
SN-ST
48 dB(A)
R 600a
220 – 240V~ / 1.5 A
forced-air
automatic
+3°C to +16°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
forced-air
automatic
+3°C to +16°C
steel / white
glass door
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
LED lighting, with separate switch
3
440 / 420
wire shelves plastic-coated
45 kg
ergonomic slimline handle
fitted
yes
right, reversible on site
46 / 43 kg
SN-ST
45 dB(A)
R 600a
220 – 240V~ / 1.0 A
forced-air
automatic
+3°C to +16°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
Total gross / net capacity
Total gross / net capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system
Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Power failure alarm
Fault: warning signal
Interface / Volt-free alarm contact
Adjustable shelves
Usable shelf area in mm (w / d)
Shelf material
Shelf loading
Drawers
Handle
Lock
Self-closing door
Door hinges
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
7112313
7112313
7112313
9876687
9590521
9590523
7112313
9876687
9590521
9590523
9590407
9590387
on request
9590407
9590387
on request
Accessories
Shelf, plastic-coated
Stacking kit, white
Roller bars
Evaporator cover, white
Adjustable legs
NTC product temperature probe
RS 485 / RS 232 adapter, data log software
Additional lock barrels (up to 10)
22
9590525
9590233
9590407
9590387
on request
5
440 / 420
wire shelves plastic-coated
60 kg
ergonomic slimline handle
fitted
yes
right, reversible on site
71 / 65 kg
SN-ST
48 dB(A)
R 600a
220 – 240V~ / 1.5 A
9590525
9590233
9590407
9590387
on request
* measured at +25 °C ambient temperature and +5 °C set temperature for fridges and -20 °C for freezers
3
440 / 420
wire shelves plastic-coated
60 kg
ergonomic slimline handle
fitted
yes
right, reversible on site
39 / 37 kg
SN-ST
45 dB(A)
R 600a
220 – 240V~ / 1.0 A
fridge compartment
freezer compartment
fridge compartment
freezer compartment
fridge / freezer comp.
fridge / freezer comp.
fridge / freezer comp.
fridge compartment
fridge compartment
fridge / freezer comp.
fridge / freezer comp.
freezer compartment
Accessories
Grid shelf, plastic-coated, for
fridge compartment
Evaporator cover, white, for
fridge compartment
NTC product temperature probe
RS 485 / RS 232 adapter, data log software
Additional lock barrels (up to 10)
254 / 240 litre
107 / 105 litre
600 / 615 / 2000
440 / 435 / 1105
431 / 435 / 597
1.800 kWh
forced-air / static
automatic / manual
+3°C to +16°C / -9°C to - 30°C
steel / white
steel
commercial grade moulded polystyrol
electronic controller
external digital
when mains power return
visual and audible
RS 485 / yes
4
440 / 420
wire shelves plastic-coated / glass
45 kg / 24 kg
3
ergonomic slimline handle
fitted
yes
right, reversible on site
91 / 85 kg
SN-ST
52 dB(A)
R 600a
220 – 240V~ / 1.5 A
7112313
9590391
9590407
9590387
on request
* measured at +25 °C ambient temperature and +5 °C set temperature for fridges and -20 °C for freezers
23
Laboratory chest freezer up to - 45°C
The advantages at a glance
Sturdy, one-piece and easy-to-clean lid. The strong lid hinges are
designed for at least 300,000 openings.
Visual and audible temperature
alarms alert the user if temperature
deviation limits are exceeded. The
parameters for the temperature alarm
can be individually set. The integrated
data memory with min/max temperatures
in the Comfort electronic controller
logs possible temperature fluctuations with date, time and duration of the alarm. In
addition the electronic controller ensures high temperature consistency in the interior.
All laboratory chest freezers are designed in accordance with ISO 60068-3.
The aluminium handle on the
LGT models is simple and tough for
intensive commercial use. All
appliances have locks as standard.
The lid has an integrated,
energy-efficient LED interior light
to improve visibility in the interior.
Volt-free contact in chest freezers with Comfort electronic controller for
forwarding alarms to an external remote warning system.
Precision Comfort electronic controller with digital temperature display for
accurate temperature setting. Thanks to its position on the chest rear, the
electronic controller can be connected to external systems.
Access port (diameter 10 mm) for
integration of the optionally available NTC
temperature sensor or independent
temperature sensor PT 100 or similar
measuring instruments.
The precision Comfort electronic
controller ensures maximum
temperature stability and high
temperature consistency in
the interior.
Stop
Frost
Laboratory chest freezers with a Comfort electronic controller are equipped with
1-point calibration for accurate temperature control.
The StopFrost system fitted to the LGT models reduces
frosting of the interior and the freezer contents – so the timeconsuming process of defrosting is necessary far less often.
The vacuum is also equalised quickly after the lid is opened
and closed so that the chest can be re-opened effortlessly.
LGT 2325
24
25
Laboratory chest freezer up to - 45°C
Quality right down to the smallest detail
The Liebherr laboratory chest freezers up to -45°C are available in three different sizes and are specially designed for the
requirements in the research, laboratory, healthcare and industrial sector. The 1-point calibration ensures high temperature
consistency. Integrated alarm systems and external temperature and alarm monitoring contribute to the safe storage of samples,
chemicals and research materials.
+0.5°C
Cal.
External temperature and alarm documentation.
The laboratory chest freezers are equipped with a volt-free
contact for alarm forwarding to an external remote warning
system. In addition, they have an RS 485 serial interface for
central documentation of the temperature profiles and alarm
events.
Integrated alarm systems.
Visual and audible alarm systems alert the user to undesired
temperature deviations or when the door is open. All alarm
parameters can be individually set. For example, the lid-open
alarm delay can be adjusted between 1 and 5 minutes.
Additional safety is provided by a visual power failure alarm
and sensor defect alarm.
26
The Comfort electronic controller.
The precision Comfort electronic controller with digital
temperature display enables temperatures to be set accurately.
Symbols indicate the operating status of the appliance. To
ensure the level of hygiene required in the laboratory, the
electronic controller is flush-mounted and equipped with a
membrane keyboard.
Integrated data memory.
The Comfort electronic controller is equipped with an integrated
data memory which logs the maximum and minimum internal
temperatures as well as the last three temperature alarms
and power failures, together with the time, date and duration.
These data can be read out on the display.
Stop
Frost
5.0°C +0.5°C
Accurate 1-point calibration.
The laboratory chest freezers are equipped with 1-point
calibration for accurate temperature control. This permits
compensation between the set temperature and the actual
internal temperature. Positive or negative changes to the
correction value can be made in steps of 0.1 K.
StopFrost System.
The StopFrost system fitted to the LGT models offers several
key advantages: frosting of the freezer compartment and its
contents is reduced and the time-consuming process of
defrosting is necessary far less often. The vacuum is also
equalised after the chest lid is opened and closed so that the
laboratory chest can be re-opened effortlessly.
External temperature sensor.
The laboratory chest freezers have an access port (diameter
10 mm) on the rear which allows temperature sensor to be
positioned in the interior.
Maximum temperature consistency.
The dynamic cooling system in conjunction with the precision
Comfort electronic controller ensures maximum temperature
stability. All laboratory chest freezers with a Comfort electronic
controller are designed according to the ISO 60068-3
standard with regard to optimum temperature consistency.
27
Laboratory chest freezers up to - 45°C
Laboratory chest freezers LGT 4725 MediLine
LGT 3725 MediLine
LGT 2325 MediLine
459 / 431 litre
1648 / 808 / 919
1445 / 500 / 650
4.352 kWh
365 / 342 litre
1373 / 808 / 919
1170 / 500 / 650
2.928 kWh
215 / 200 litre
1132 / 760 / 919
889 / 410 / 630
2.256 kWh
static
manual
-10°C to -45°C
steel / white
steel
white coated aluminium
electronic controller
external digital
when mains power return
RS 485 / yes
100 – 100 mm
0
16
LED
profiled aluminium
fitted
94 / 81 kg
SN
55 dB(A)
R 290
220 – 240V~ / 3.5 A
static
manual
-10°C to -45°C
steel / white
steel
white coated aluminium
electronic controller
external digital
when mains power return
RS 485 / yes
100 – 100 mm
0
13
LED
profiled aluminium
fitted
82 / 71 kg
SN
55 dB(A)
R 290
220 – 240V~ / 3.0 A
static
manual
-10°C to -45°C
steel / white
steel
white coated aluminium
electronic controller
external digital
when mains power return
RS 485 / yes
120 – 120 mm
0
10
LED
profiled aluminium
fitted
68 / 58 kg
SN
55 dB(A)
R 290
220 – 240V~ / 2.0 A
9590407
9590387
7112947
9901627
9590407
9590387
7112947
9901627
9590407
9590387
7112317
9901629
up to - 45°C
Total gross / net capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system
Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Power failure alarm
Interface / Volt-free alarm contact
Insulation
Number of baskets
Number of baskets, max
Interior light
Handle
Lock
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
Accessories
NTC product temperature probe
RS 485 / RS 232 adapter, data log software
Baskets
Roller bars
28
* measured at +25 °C ambient temperature and -45 °C set temperature
29
Laboratory refrigerators with analogue controls and spark-free interior
The advantages at a glance
Quality right down to the
smallest detail
Certified according to ATEX 95.
The LKexv models are labelled clearly and permanently on the
outer housing in accordance with the ATEX Directive 94/9 EC,
including information for cleaning. Rated as II 3G Ex nA II T6,
these appliances are suitable for storing explosive and highly
flammable substances in sealed containers.
The LKexv models are labelled
clearly and permanently on the outer
housing in accordance with the
ATEX Directive 94/9 EC, including
information for cleaning.
The moulded polystyrol inner liner
with large corner radii is exceptionally
easy to clean and enables optimum
hygiene.
Hygienic interior for versatile use.
The commercial-grade moulded polystyrol inner liner is
exceptionally easy to clean and enables optimum hygiene.
The moulded trayslides prevent the glass shelves from
tipping and allow them to be varied in height.
The sturdy glass shelves are
easily adjustable in height and can
conveniently be removed at a door
opening angle of 90 °. They ensure
secure storage and have a loading
capacity of up to 40 kg.
Glass shelves.
The glass shelves ensure secure storage even for small
items and have a loading capacity of up to 40 kg.
The integrated lock is exceedingly
sturdy and protects the stored products
against unauthorised access.
Sealed defrost water drain in the
laboratory appliances with spark-free
interior for compliance with the ATEX
Directive 94/9 EC.
Water tray.
The defrost water drain in the laboratory appliances with
spark-free interior is sealed for compliance with the ATEX
Directive 94/9 EC. The defrost water obtained during the
automatic defrost cycle is collected in a tray which has to
be emptied manually at regular intervals.
Reversible door hinges in the
LKexv models enable individual
adaption to space conditions. The
door seals can also be easily
replaced as required.
LKexv 5400
30
31
Laboratory refrigerators with mechanical control and spark-free interior
Laboratory refrigerators LKexv 5400 MediLine
LKexv 3600 MediLine
LKexv 2600 MediLine
LKexv 1800 MediLine
554 / 520 litre
750 / 730 / 1640
600 / 560 / 1452
0.983 kWh
333 / 307 litre
600 / 610 / 1640
470 / 440 / 1452
0.947 kWh
240 / 221 litre
600 / 610 / 1250
470 / 440 / 1062
0.786 kWh
180 / 160 litre
600 / 600 / 860
513 / 441 / 702
0.898 kWh
forced-air
automatic
+1°C to +15°C
steel / white
steel
commercial grade moulded polystyrol
analogue controls
external digital
5
600 / 550
glass
40 kg
ergonomic slimline handle
fitted
right, reversible on site
84 / 77 kg
SN-T
48 dB(A)
R 600a
220 – 240V~ / 1.5 A
forced-air
automatic
+1°C to +15°C
steel / white
steel
commercial grade moulded polystyrol
analogue controls
external digital
5
470 / 425
glass
40 kg
ergonomic slimline handle
fitted
right, reversible on site
64 / 59 kg
SN-T
48 dB(A)
R 600a
220 – 240V~ / 1.5 A
forced-air
automatic
+1°C to +15°C
steel / white
steel
commercial grade moulded polystyrol
analogue controls
external digital
4
470 / 425
glass
40 kg
ergonomic slimline handle
fitted
right, reversible on site
53 / 49 kg
SN-T
48 dB(A)
R 600a
220 – 240V~ / 1.0 A
forced-air
automatic
+1°C to +15°C
steel / white
steel
commercial grade moulded polystyrol
analogue controls
external digital
3
513 / 412
glass
40 kg
ergonomic slimline handle
fitted
right, reversible on site
40 / 38 kg
SN
44 dB(A)
R 600a
220 – 240V~ / 1.0 A
9293613
9086365
9590233
on request
9293615
9086323
9590233
on request
9293615
9086323
9590233
on request
9293631
with mechanical control and
spark-free interior
Total gross / net capacity
Exterior dimensions in mm (w / d / h)
Interior dimensions in mm (w / d / h)
Energy consumption in 24 h *
General
Cooling system
Defrost
Temperature range
External cabinet finish
Door / lid material
Internal liner material
Type of control
Temperature display
Adjustable shelves
Usable shelf area in mm (w / d)
Shelf material
Shelf loading
Handle
Lock
Door hinges
Gross / net weight
Climate rating
Sound power level
Refrigerant
Voltage / Connection rating
Accessories
Glass shelf
Castor base
Adjustable legs
Additional lock barrels (up to 10)
32
* measured at +25 °C ambient temperature and +5 °C set temperature
33
Accessories
Section: Laboratory refrigerators and freezers with Profi electronic controller
U-shaped trayslides and plastic-coated shelves
Additional U-shaped trayslides and plastic-coated grid shelves can be retrofitted as required to provide extra storage options. The
sturdy grid shelves have an extremely high loading capacity of up to 60 kg.
Infrared key with documentation software
The alarm events and temperature profile data can be read out using the infrared key available as an accessory. Corresponding
documentation software is included allowing visualisation of the read-out data on a PC.
Interface converter with monitoring software
A special interface converter including the Liebherr LTM monitoring software is available for central documentation of the
temperature profile data and alarm events of multiple appliances via the RS 485 serial interface. It is possible to network as many
as 20 laboratory appliances and centrally document their parameters. Alarm forwarding or regular status reports to up to three
email addresses can be confi gured as an additional feature. Alternatively, commercially available converters can be used to
connect the appliances to a PC via WLAN or LAN. Software requirements: PC with Windows ® operating system.
NTC product temperature sensor
An NTC product temperature sensor for logging product temperatures is available as a retrofit kit for the laboratory appliances with
a Profi electronic controller. The logged product temperatures can either be read by the electronic controller or transferred to an
external documentation system via the existing RS 485 interface.
Section: Laboratory refrigerators and freezers with
Comfort electronic controller and spark-free interior
NTC spark-free product temperature sensor
An NTC product temperature sensor for logging product temperatures is available as a retrofi t kit for the spark-free laboratory
appliances with a Comfort electronic controller. The logged product temperatures can either be read by the electronic controller
or transferred to an external documentation system via the existing RS 485 interface.
34
35
Accessories
Section: Laboratory refrigerators and freezers with Comfort electronic controller and spark-free interior
Interface converter with monitoring software
Evaporator cover
A special interface converter including LTM monitoring software is available for central documentation of the temperature profile data
An evaporator cover can be installed for added safety, to ensure that cold-sensitive products cannot touch the evaporator.
and alarm events of multiple appliances via the RS 485 serial interface. Capability is provided for interconnecting as many as 20
laboratory appliances and centrally documenting their parameters. Alarm forwarding or regular status reports to up to three email
addresses can be configured as an additional feature. Commercially available converters can be used to connect the connected
appliances to a PC via WLAN or LAN. Software requirements: PC with Windows® operating system.
Section: Laboratory refrigerators and laboratory fridge-freezer
with Comfort electronic controller
Additional lock barrels
NTC product temperature sensor
Up to 10 additional lock barrels to protect the stored products against unauthorised access are available as accessories for the
An NTC product temperature sensor for logging product temperatures is available as a retrofit kit for the laboratory appliances with
laboratory appliances with a Comfort electronic controller. In case of multiple appliances, different locks can be installed to ensure
a Comfort electronic controller. The logged product temperatures can either be read by the electronic controller or transferred to an
that the respective appliance can only be accessed by the staff members responsible for it.
external documentation system via the existing RS 485 interface.
Glass shelves
Interface converter with monitoring software
Additional glass shelves can be retrofitted to the LCexv, LKexv and LKUexv models as required to provide extra storage options. The
A special interface converter including LTM monitoring software is available for central documentation of the temperature profile
glass shelves made of toughened safety glass meet the standards for spark-free refrigerators in accordance with ATEX 95 and have
data and alarm events of multiple appliances via the RS 485 serial interface. Capability is provided for interconnecting as many
a loading capacity of up to 40 kg.
as 20 laboratory appliances and centrally documenting their parameters. Alarm forwarding or regular status reports to up to three
email addresses can be configured as an additional feature. Alternatively commercially available converters can be used to connect
the appliances to a PC via WLAN or LAN. Software requirements: PC with Windows® operating system.
Stacking kit
Additional lock barrels
A stacking kit is available as an accessory for combining the LKUexv and LGUex models as well as other under-worktop models in
Up to 10 additional lock barrels to protect the stored products against unauthorised access are available as accessories for the
the LKUv range. This allows stacking laboratory fridge-freezers on a small footprint.
laboratory appliances with a Comfort electronic controller. In case of multiple appliances, different locks can be installed to ensure
that the respective appliance can only be accessed by the staff members responsible for it.
Roller sets and adjustable-height feet
Stacking kit
30 mm high roller sets can be retrofitted to the under-worktop LKUexv 1610 and LGUex 1500 models and adjustable-height feet can
A stacking kit is available for combining the LKUv 1613, LKUv 1610, LKUexv 1610 and LGUex 1500 models as desired. This allows
be retrofitted to the LKexv 3910 and LGex 3410 models to allow easy cleaning underneath. The feet are adjustable between 115 mm
stacking a glass door appliance and solid door appliance or a refrigerator and freezer on a small footprint.
and 170 mm in height.
36
37
Accessories
Section: Laboratory refrigerators and laboratory fridge-freezer with Comfort electronic controller
Evaporator cover
Optional high-quality baskets
An evaporator cover can be installed for added safety, to ensure that cold-sensitive products cannot touch the evaporator.
The optional baskets provide an optimum overview of the stored preparations and can help to improve the handling and organising
of the freezer contents.
Section: Laboratory refrigerators with analogue controls and
spark-free interior
Roller sets and adjustable-height feet
Glass shelves
30 mm high roller sets can be retrofitted to the under-worktop LKUv models and adjustable-height feet can be retrofitted to the
Additional glass shelves can be retrofitted to the LCexv, LKexv and LKUexv models as required to provide extra storage options. The
LKv models to allow easy cleaning underneath. The feet are adjustable between 115 mm and 170 mm in height.
glass shelves made of toughened safety glass meet the standards for spark-free refrigerators in accordance with ATEX 95 and have
a loading capacity of up to 40 kg.
Plastic-coated grid shelves
Castor base
Additional plastic-coated grid shelves can be retrofitted as required to provide extra storage options. The sturdy grid shelves have
A castor base is available as an accessory for the LKexv models to allow flexible use of the appliances in different rooms.
an extremely high loading capacity of up to 45 kg.
Section: Laboratory chest freezers up to -45°C
NTC product temperature sensor
Adjustable-height feet
An NTC product temperature sensor for logging product temperatures is available as a retrofit kit for the laboratory chest freezers
Adjustable-height feet can be retrofitted to the LKexv models for easy cleaning underneath. They are adjustable between 115 mm
with a Comfort electronic controller. The logged product temperatures can either be read by the electronic controller or transferred
and 170 mm in height.
to an external documentation system via the existing RS 485 interface.
Interface converter with documentation software
Additional lock barrels
A special interface converter including LTM documentation software is available for central documentation of the temperature
Up to 10 additional lock barrels to protect the stored products against unauthorised access are available as accessories for the
profile data and alarm events of multiple appliances via the RS 485 serial interface. It is possible to network as many as 20
laboratory appliances with a Comfort electronic controller. In case of multiple appliances, different locks can be installed to ensure
laboratory appliances and centrally monitor their parameters. Alarm forwarding or regular status reports to up to three email
that the respective appliance can only be accessed by the staff members responsible for it.
addresses can be configured as an additional feature. Commercially available converters can be used to connect the connected
appliances to a PC via WLAN or LAN. Software requirements: PC with Windows ® operating system.
38
39
Was this manual useful for you? yes no