Product Image
1
Frost Protection
20
Table of Contents
2
Power ON/OFF
21
What is a Programmable
Room Thermostat?
3-4
Installation Procedure
5-6
Mode Select
7
Pairing the neoHub
8
Pairing the neoStat-e
8-9
Holiday Programming
Optional Features
22
23-26
Re-calibrating the Thermostat
27
Error Codes
27
Thermostat Mode Wiring Diagram
28
What is a Mesh Network?
9
Mode 2 - Time Clock
Mode 1 - Thermostat
10
LCD Display
29
29-30
Setting the Switching Times
31
Temperature Display
13
Factory Reset
32
Setting the Clock
14
Timer Override
33
Optional Features
34
LCD Display
Setting the Comfort Levels
11-12
15-16
Setting the Temperature
17
Optional Features Table
34
Temperature Hold
18
Time Clock Mode Wiring Diagram
35
Locking/Unlocking the neoStat-e
19
Battery Replacement
36
22
What
is aHeader
Programmable Room Thermostat?
Section
A programmable room thermostat is both a programmer and a room thermostat.
A programmer allows you to set “On” and “Off” periods to suit your own lifestyle.
A room thermostat works by sensing the air temperature, switching on the heating
when the air temperature falls below the thermostat setting, and switching it off once
this set temperature has been reached.
So a programmable room thermostat lets you choose what times you want the heating
to be on, and what temperature it should reach while it is on. It will allow you to select
different temperatures in your home at different times of the day (and days of the week)
to meet your particular needs and preferences.
Setting a programmable room thermostat to a higher temperature will not make the
room heat up any faster. How quickly the room heats up depends on the design and
size of the heating system.
Similarly reducing the temperature setting does not affect how quickly the room cools
down. Setting a programmable room thermostat to a lower temperature will result in
the room being controlled at a lower temperature, and saves energy.
33
Series
Series
Section Header
The way to set and use your programmable room thermostat is to find the lowest
temperature settings that you are comfortable with at the different times you have
chosen, and then leave it alone to do its job.
The best way to do this is to set the room thermostat to a low temperature
– say 18°C , and then turn it up by 1°C each day until you are comfortable with the
temperature. You won’t have to adjust the thermostat further. Any adjustment above
this setting will waste energy and cost you more money.
You are able to temporarily adjust the heating program by overriding or using the
temperature hold feature. These features are explained further on pages 17 and 18
of this manual.
Programmable room thermostats need a free flow of air to sense the temperature,
so they must not be covered by curtains or blocked by furniture. Nearby electric
fires, televisions, wall or table lamps may also prevent the thermostat from working
properly.
4
Installation
Procedure
Section Header
Do
Mount the thermostat at eye level.
Read the instructions fully so you get the best from our product.
Don’t
Do not install near to a direct heat source as this will affect functionality.
Do not push hard on the LCD screen as this may cause irreparable damage.
This neoStat-e is designed to be flush mounted and requires a back box of
35mm (minimum depth) to be sunk into the wall prior to installation.
Step 1
Remove the screw from the bottom face of the thermostat then carefully separate
the front half from the back plate.
Step 2
Place the thermostat front somewhere safe.
Terminate the thermostat as shown in the diagrams on pages 28 of this booklet.
Note: For time clock wiring connections, terminate as shown on page 35.
Step 3
Screw the thermostat back plate securely into the back box.
Step 4
Clip the front of the thermostat onto the back plate, securing it in place with the
retaining screw.
55
Series
Series
1
3
Section Header
2
4
6
Mode
Select
Section
Header
This neoStat-e can either be used as a thermostat or a time clock.
Thermostat mode is the default setting.
To change between thermostat or time clock modes, follow these steps.
•
•
•
Use the Left / Right keys to scroll to SETUP .....................................................
Press and hold the Tick key for 10 seconds ......................................................
Use the Left / Right keys to scroll between modes ........................................
Mode 1 = Thermostat
Mode 2 = Time Clock
Note: the selected option will flash.
•
Press the Tick key to confirm selection .............................................................
The neoStat-e will revert to the main display screen for the selected mode.
For time clock mode instructions, first pair the time clock with the neoHub as
explained on page 8, then turn to page 29.
77
Series
Series
Pairing
neoHub
Sectionthe
Header
To pair the neoHub with the neoApp, follow these steps.
• Connect the power supply to the neoHub.
• Connect the neoHub to your router with the Ethernet cable provided. The router
will automatically assign an IP address to the neoHub, the Link LED will light up
once the neoHub has connected to your network.
• Connect your smartphone or tablet device to the same WiFi network as your router.
• Download the FREE Heatmiser neoApp from the Apple App Store,
Google Play Store, Amazon App Store or Windows Phone App Store and register
an account.
• Once you have registered your account, press the Login button then press the
Add Location option.
• Press the connect button on the neoHub to add the location to your account.
• When successfully connected, enter a title for the new location (e.g. Home) and
configure the time zone for the system.
Pairing the neoStat
The next step is to join the neoStat-e to the neoHub, we recommend joining the
neoStat-e located nearest to the neoHub first.
To add a neoStat-e, follow these steps;
• Select Add Zone, enter a zone title and press Add Zone again.
• You now have two minutes to join the neoStat-e to the neoHub.
• On the neoStat-e, use the Left / Right keys to select SETUP and press Tick.
8
•
•
•
•
Feature 01 is displayed on screen.
Press the Tick key to pair the neoStat-e to the neoHub ....................................
The MESH symbol appears flashing on the display.
When the neoStat-e successfully connects to the neoHub the MESH symbol will
be permanently displayed.
• Press Next to add more zone or press Finish to complete the setup.
Please note, you only have to pair the hub to your account once. To pair any additional
neoStats, select Add Zones from the Manage Zones option in the neoApp.
Section Header
What is a Mesh Network
NeoStats work using a mesh network, meaning neoStats have the ability to send and
receive signals via other thermostats/time clocks on the network.
This signal is relayed from one device to another until it reaches its destination.
This communication method extends the communication range whilst offering
increased network stability when compared with standard RF thermostats.
The Mesh symbol is shown when the device is communicating with the neoHub,
if the mesh symbol disappears this indicates connection to the neoHub has been lost.
99
Series
Series
Mode
1 - Header
Thermostat
Section
10
10
2 Header
1Section
3
4
5
15
14
13
6
12
7
8
9
11
10
11
Series
Series
LCD
Display
Section
Header
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
Day Indicator - Displays the day of the week.
Mesh Symbol – Displayed when connected to the neoHub.
Floor Limit Symbol – Displayed when the floor probe has reached the
temperature limit set on feature 07.
Frost Symbol – Displayed when frost protection mode is active.
Flame Symbol – Displayed when the thermostat is calling for heat, flashes when
optimum start is active.
Floor/Room Temp – Indicates the current sensor mode.
Set – Displayed when changes are being made to the program schedule or
current set point.
Key Lock Indicator – Displayed when the KeyLock is Locked.
Program Indicator – Displayed during programming to show which period is
being altered.
Main Menu – Displays which option is currently selected.
Temperature Format – Degrees Celsius or Fahrenheit.
Temperature – Displays the current sensor temperature.
Clock - Time displayed in 24 hour format.
Holiday Left – Displayed when the thermostat is in holiday mode.
Hold Left – Displayed when a temperature hold is active, the remaining time
will be shown.
12
12
Temperature
Display
Section Header
This neoStat-e can be configured for different sensor options such as built in air sensor,
floor sensor or both. The display will clearly indicate which sensor is being used by
showing either “Room Temp” or “Floor Temp” before the actual temperature value.
Room Temperature
Floor Temperature
When the neoStat-e is set to use both the air & the floor sensor, the room temperature
will be displayed by default.
To view the current floor temperature, press and hold the Left and Right arrow keys
for 5 seconds, the floor temperature will then be displayed. .......................................
13
Series
Series
Setting
Clock
Sectionthe
Header
To set the clock, follow these steps.
•
Use the Left / Right keys to scroll to CLOCK ........................................................
•
Press Tick to confirm selection ...........................................................................................
•
Use the Up / Down keys to set the hours (24 hour format) ............................
•
Press Tick to confirm selection ...........................................................................................
•
Use Up / Down keys to set the minutes ................................................................
•
Press Tick to confirm selection ...........................................................................................
•
Use Left / Right keys to set the the day .................................................................
•
Press Tick to confirm selection and return to the main display ...........................
Day
Hours
Minutes
14
14
Comfort
Levels Explained
Section Header
The neoStat-e offers three program mode options; Weekday/Weekend programming,
7 Day programming and 24 Hour programming. There is also the option to
use the thermostat as a Non-Programmable thermostat.
When thermostats are connected to the mesh network, the program mode for the system
is configured by using the neoApp.
The thermostat is supplied with comfort levels already programmed, but these can be
changed easily. The default times and temperature settings are;
07:00 - 21°C (Wake)
09:00 - 16°C (Leave)
16:00 - 21°C (Return)
22:00 - 16°C (Sleep)
If you only want to use 2 levels, you should program the unused levels to
--:--
For Weekday/Weekend programming, the four comfort levels are the same for Mon-Fri, but can
be different for Sat-Sun. For 7 Day programming each day of the week can have four different
comfort levels. In 24 Hour mode all days are programmed with the same comfort levels.
•
To program the comfort levels, use the Left / Right keys to scroll to EDIT .............
•
Press Tick to confirm selection .......................................................................................................
•
Use the Left / Right keys to select day / period of week (the selection will flash).
•
Press Tick to confirm selection ........................................................................................................
•
WAKE will now flash and the current time and temperature setting will be shown.
•
Press Tick to alter WAKE settings ..................................................................................................
15
Series
Series
Section Header
•
Use the Up / Down keys to set the hours ..............................................................
•
Press Tick to confirm ..............................................................................................................
•
Use the Up / Down keys to set the minutes .........................................................
•
Press Tick to confirm ..............................................................................................................
•
Use the Up / Down keys to set the temperature .................................................
•
Press Tick to confirm the settings .....................................................................................
•
Press the Right arrow key .....................................................................................................
•
LEAVE will now flash and the current settings will be displayed.
•
Press Tick to alter LEAVE settings ......................................................................................
•
Repeat these steps to set all comfort levels.
•
For any unused periods set time to --:--
•
Use the Left / Right keys to scroll to DONE and press Tick .......................
16
16
Temperature
Control
Section Header
The Up / Down keys allow you to adjust the set temperature .............................
When you press either key, you will see the word SET and the desired
temperature value. Use the Up / Down keys to adjust the SET value ...............
Press Tick to confirm settings and return to the main display ....................................
Set Temperature
Set Icon
Note: This new temperature is maintained only until the next programmed comfort level.
At this time, the thermostat will revert back to the programmed levels.
17
Series
Series
Temperature
Hold
Section Header
The temperature hold function allows you to manually override the current operating
program and set a different temperature for a desired period.
•
Use the Left / Right keys to scroll to HOLD ...........................................................
•
Press Tick to confirm selection ..........................................................................................
•
Use the Up / Down keys to set the desired Hold period .................................
•
Press Tick to confirm selection ..........................................................................................
•
Use the Up / Down keys to set the desired Hold temperature ......................
•
Press Tick to confirm selection ..........................................................................................
You will see the HOLD LEFT indication is displayed on screen.
The time will countdown the set duration and then revert to the normal program.
HOLD LEFT Indicator
Hold Time Remaining
To cancel a temperature Hold, repeat these steps but reduce the Hold time to 00:00 hrs
18
18
Locking
the neoStat-e
Section Header
The thermostat has a keypad lock facility. To activate the lock follow these steps.
•
Use the Left / Right keys to scroll to HOLD & press Tick for 10 seconds
•
The display will show 00:00 and you will need to enter a four digit pin number.
•
Use the Up / Down keys to enter the first two digits .......................................
•
Press Tick to confirm .............................................................................................................
•
Use the Up / Down keys to enter the second two digits ................................
•
Press Tick to confirm ............................................................................................................
The display will return to the main screen and display the keypad lock indicator .....
Note: The keypad lock indicator is only displayed when the lock is active.
Unlocking the neoStat-e
To unlock the neoStat-e press Tick once. The display will show 00:00 and you will need to
enter the four digit pin number you set previously.
•
Use the Up / Down and Tick keys to enter the first two digits ............
•
Use the Up / Down and Tick keys to enter the second two digits .....
The display will unlock and return to the main screen.
19
Series
Series
Frost
Mode
Section
Header
Use the Left / Right keys to scroll to the Power Icon ..............................................
The frost icon will toggle ON/OFF each time Tick is pressed ...................................................
In this mode, the neoStat-e will display the frost icon and will only turn the heating
ON should the room temperature drop below the set frost temperature (see page 23).
If the heating is turned ON whilst in frost mode, the flame symbol will be displayed.
To cancel the frost protect mode, navigate to the Power button again and press Tick.
Frost Protection Mode Enabled
20
20
Power
SectionOn/Off
Header
The heating is indicated ON when the flame icon is displayed.
When the flame icon is absent, there is no requirement for heating to achieve the set
temperature but the neoStat remains active.
To turn the neoStat-e off completely, scroll to the Power Icon and hold
the Tick key for approximately 4 seconds until the display goes blank ...................
The display and heating output will be turned OFF.
To turn the thermostat back ON, press the Tick key once .............................................................
Thermostat completely OFF
21
Thermostat powered ON
Series
Series
HolidayHeader
Section
In thermostat mode, the holiday function reduces the set temperature in your home
to the frost protection temperature setting (see page 23).
In time clock mode, the holiday function maintains the timed output as OFF.
The thermostat will maintain this temperature for the duration of the holiday and will
then automatically return to the program mode on your return.
•
Use the Left / Right keys to scroll to HOLIDAY and press Tick ...............
•
Using the Up / Down keys enter the number of days holiday .....................
•
Press Tick to confirm settings ............................................................................................
Note: A holiday period does not start until 00:00 the next day. For example, if you set
a holiday period on Friday for 2 days, Saturday will be counted as the first day and the
thermostat will revert back to the programmed schedule at 00:00 on Monday.
To cancel, repeat these steps but reduce the Holiday duration to 00 days.
22
22
Optional
Features Explained
Section Header
THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES
NEED NOT BE ADJUSTED.
Feature 01 – Pairing To neoHub: This function is used to connect the thermostat to the
neoHub.
Feature 02 - Switching Differential: This function allows you to increase the switching
differential of the thermostat. The default is 1°C which means that with a set temperature
of 20°C, the thermostat will switch the heating on at 19°C and off at 20°C. With a 2°C
differential, the heating will switch on at 18°C and off at 20°C.
Feature 03 - Frost Protect Temperature: This is the temperature maintained when the
thermostat is in Frost Mode. The range is 07 - 17°C. The default is 12°C and is suitable for
most applications.
Feature 04 – Output Delay: To prevent rapid switching, an output delay can be entered.
This can be set from 00 - 15 minutes. The default is 00 which means there is no delay.
Feature 05 – Temperature Up/Down Limit: This function allows you to limit the use of the
up and down temperature arrow keys. This limit is also applicable when the thermostat is
locked and so allows you to give others limited control over the heating system.
Feature 06 – Sensor Selection: On this neoStat-e, you can select which sensor should be
used. You can select between air temperature only, floor temperature, or both. When you
enable both sensors, the floor sensor is used as a floor limiting sensor and is designed to
prevent the floor from overheating.
Feature 07 – Floor Temp Limit: This function is available when mode 07 is set to 03 or 04.
You can set a floor limiting temperature between 20-45°C (28°C is the default setting).
23
Series
Series
Note: Air Sensor only MUST NOT be used to control electric under-floor heating.
Floor Sensor or Both should be used.
Feature 08 – Optimum Start: Optimum start will delay the start up of the heating
system to the latest possible moment to avoid unnecessary heating and ensure
the building is warm at the programmed time. The thermostat uses the rate of
change information to calculate how long the heating needs to raise the building
temperature 1°C (with a rate of change of 20, the thermostat has calculated the
heating needs 20 minutes to raise the building temperature 1°C) and starts the
heating accordingly.
Feature 09 - Rate of Change: Number of minutes for 1°C temperature rise.
Feature 10 – Cool Enable: Not Used On This Model
Feature 11 – Cool Set Temperature: Not Used On This Model
Feature 12 – Program Mode: Non-Programmable, Weekday/Weekend (5/2),
7 Day Programming or 24 Hour. The thermostat offers three programming modes and
the option of configuring it to work as a non-programmable thermostat.
Weekday/ Weekend - allows you to program 4 comfort levels for the weekday
and 4 different comfort levels for the weekend.
7 Day Program Mode - Each day has 4 comfort levels that can be programmed
independently.
24 Hour Mode - All days are programmed the same and repeat continuously.
Feature 13 - Temperature Format: This function allows you to select between
°C and °F.
Section Header
24
24
Adjusting
the Optional Settings
Section Header
•
Use the Left / Right keys to select SETUP ..............................................................
•
Press Tick to confirm selection ..................................................................................
Feature Number
Setting Value
•
Use the Up / Down keys to scroll through features ..........................................
•
Use the Left / Right keys to adjust the setting within each feature ...........
•
Press Tick to confirm settings ....................................................................................
25
Series
Series
Optional
Settings - Feature Table
Section
Header
FEATURE
DESCRIPTION
SETTING
01
02
Pairing
Switching Differential
03
04
05
06
Frost Protection Temperature
Output Delay
Up/Down Temperature Limit
Sensor Selection
07
08
09
10
11
12
Floor Temperature Limit
Optimum Start
Rate of Change
Cool Enable
Cool Set Temperature
Program Mode
13
Temperature Format
Used to add zone to the neoHub
00 = 0.5oC
01 = 1.0oC (Default)
02 = 2.0oC
03 = 3.0oC
07o - 17oC (12oC = Default)
00 - 15 Minutes (00 = Default)
00o - 10oC (00 = Default)
00 = Built in Sensor (Default)
01 = Remote Air Sensor
02 = Floor Sensor Only
03 = Built in & Floor Sensor
04 = Remote Air & Floor Sensor
20oC - 45oC (28oC = Default)
00-05 (00 = Default)
Minutes to raise by 1oC
Not Used On This Model
Not Used On This Model
00 = Non - Programmable
01 = Weekday/Weekend (Default)
02 = 7 Day Programming
03 = 24 Hour Mode
00 = oC, 01 = oF (00 = Default)
26
26
Re-calibrating
Section Headerthe Thermostat
If you need to re-calibrate the thermostat, follow these steps.
•
Use the Left / Right keys to scroll to the Power Icon ............................
•
Press and hold Tick to turn the display OFF ...........................................................
•
Press and hold the Tick and Down keys together for 10 seconds ..................
•
The current temperature will appear on the display.
•
Use the Up / Down keys to configure the new temperature value ..............
•
Press the Tick key to confirm the change and the display will go blank ....
•
Press the Tick key once to turn the thermostat ON ............................................
Error Codes
When terminated for thermostat operation the screen will display an error code if a fault
is detected.
E0 = The internal sensor has developed a fault.
E1 = The remote FLOOR probe has not been connected.
The remote FLOOR probe has not been wired correctly.
The remote FLOOR probe is faulty.
E2 = The remote AIR probe has not been connected.
The remote AIR probe has not been wired correctly.
The remote AIR probe is faulty.
27
Series
Series
Wiring Header
Diagram - neoStat-e
Section
TC-EM
MAINS SUPPLY
230VAC
Floor
Sensor
RT1
RCD
Remote
Air Sensor
-
RT2 N
L
N
LOAD
N
L
FLOOR PROBE
MATTING OR WIRE - 16 AMP MAX
REMOTE AIR PROBE
(Optional)
This product must only be installed by a qualified electrician
and comply with local installation regulations.
28
28
Mode 2 Header
- Time Clock
Section
2
1
10
9
8
7
3
4
5
6
29
Series
Series
LCD
Display
Section
Header
1.
Day Indicator - Displays the day of the week.
2.
Mesh Symbol – Displayed when connected to the neoHub.
3.
Key Lock Indicator – Displayed when the KeyLock is Locked.
4.
Set – Displayed when changes are being made to the program schedule or
current set point.
5.
Program Indicator – Displayed during programming to show which period is
being altered.
6.
Main Menu – Displays which option is currently selected.
7.
Timer Status – Displays the current state of the timed output.
8.
Clock - Time displayed in 24 hour format.
9.
Holiday Left – Displayed when the thermostat is in holiday mode.
10.
Hold Left – Displayed when a temperature hold is active, the remaining time
will be shown.
30
30
Setting
Switching Times
Sectionthe
Header
To program the switching times, follow these steps.
•
Use the Left / Right keys to scroll to EDIT and press Tick .................................
•
Use the Left / Right keys to select day/period of the week .............................
•
Press Tick to confirm selection ...................................................................................
•
1 will now flash and the current ON time will be displayed.
The OFF time can be viewed by pressing the Down key ................................
•
Select a switching time and press the Tick key ....................................................
•
Use the Up / Down keys to select the ON time HOURS and press Tick .......
•
Use the Up / Down keys to select the ON time MINUTES ................................
•
Press Tick to confirm selection ..................................................................................
•
Use the Up / Down keys to select the OFF time HOURS and press Tick .....
•
Use the Up / Down keys to select the OFF time MINUTES ..............................
•
Press Tick to confirm selection ..................................................................................
•
Press the Right arrow key ............................................................................................
•
2 will now flash and the current ON time will be displayed.
•
Repeat the steps above to set all periods. For any unused periods enter -- : --
•
When complete, use the Left / Right keys to scroll to DONE and press
Tick to confirm all changes ........................................................................................
31
Series
Series
Factory
Section Reset
Header
To reset the device to factory default settings, follow these steps:
•
Use the Left / Right keys to scroll to SETUP ...........................................................
•
Press and hold the Tick key for 10 seconds ...........................................................
•
All of the icons on the display will appear for 2 seconds, then the display
will show option 1 or 2.
•
Use the Left / Right keys to scroll between modes (selection will flash) ....
Mode 1 = Thermostat
Mode 2 = Time Clock
•
Press the Tick key to confirm selection ....................................................................
The thermostat will revert to the main display screen for the selected mode.
Note: Factory reset will cancel all parameters that were entered during the set-up and
pairing operations. These processes must be repeated after factory reset is completed.
32
32
Timer
Override
Section
Header
To override the current timed output ON/OFF follow these steps.
•
Use the Left / Right keys to scroll to HOLD and press Tick .......................
•
Use the Up / Down keys to select either TIMER ON or TIMER OFF
and press Tick ...........................................................................................................
•
Use the Up / Down keys to set the override duration e.g. 01:00 hours .......
•
Press Tick to confirm settings and return to main display ...............................
Hold Left and the remaining time will now be displayed.
HOLD LEFT Indicator
Hold Time Remaining
33
Series
Series
Optional
Features Explained
Section Header
Feature 01 – Pairing To neoHub: This function is used to connect the time clock to
the neoHub.
Feature 02 - Weekday/Weekend (5/2), 7 Day Programming or 24 Hour Mode:
The time clock offers three programming methods;
Weekday/ Weekend (5/2) - Allows you to program 4 comfort levels for the
weekdays and 4 different comfort levels for the weekend days.
7 Day Program Mode - Each day has 4 comfort levels that can be
programmed independently.
24 Hour Mode - All days are programmed with the same times.
Optional Settings - Feature Table
FEATURE
DESCRIPTION
SETTING
01
Pairing
Used to pair to the neoHub
02
Program Mode
01 = Weekday/Weekend Programming (Default)
02 = 7 Day Programming
03 = 24 Hour Mode
34
34
Wiring Diagram
Section
Header - Time Clock Mode
MAINS SUPPLY
230VAC
RCD
L
RT1
-
RT2 N
N
LOAD
LOAD
N
L
16 AMP MAX
This product must only be installed by a qualified electrician
and comply with local installation regulations.
35
Series
Series
Replacing
the Battery
Section Header
In most cases the 3 volt lithium battery does not need replacing if the
thermostat has a continual power supply. Its sole purpose is to ensure correct
time keeping during a power loss to the thermostat.
To remove the battery use a small flat head screw driver or fingertip to push
back the brass retaining bracket. This will automatically release the battery.
Insert the new battery (positive side up!) by locating one end underneath
the holding clips then pushing down on the opposite end against the brass
holding bracket.
Holding clips
Brass retaining bracket
We advise that replacement of the lithium battery be
carried out by a qualified professional.
36
Notes
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
37
Model: Manual
SeriesREF
37
Notes
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
.........................................................................................................................................................................
38
Want More Information?
Call our support team on: +44 (0)1254 669090
Or view technical specifications directly on our website:
www.heatmiser.com
PDF
Twitter: @heatmiseruk
FAQ
Facebook: facebook.com/thermostats
Rev. 2.1
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement