Bosch FCP-500 manual
Bosch FCP-500 is a modern, low-profile smoke detector with a smooth, easy-to-clean surface, ideal for areas prone to dust and fibers. Its innovative retention mechanism ensures fast and simple insertion and replacement. The two-color LED indicates various operating states, such as power, trouble, and test mode. It offers high reliability and can be used with commercial fire protective signaling systems and household fire warning systems.
Advertisement
Advertisement
Fire Alarm Systems | FCP-500 Conventional Flush-mount Smoke Detectors
FCP-500 Conventional Flush-mount Smoke
Detectors
▶ Modern, ultra-low profile design
▶ Color inserts match the surrounding decor
▶ Smooth, easily-cleaned detector surface
▶ Innovative retention mechanism
▶ High reliability
▶ Four-wire technology
▶ Compatible with 12 VDC or 24 VDC systems
▶ 30 ft (9 m) spacing between detectors
▶ Optional carbon monoxide (CO) sensor for false alarm reduction
▶ Dual color LED
The FCP-500 Conventional Flush-mount Detectors are
UL Listed, open area photoelectric smoke detectors.
Use them with commercial fire protective signaling systems and household fire warning systems (see
NFPA 72, the National Fire Alarm Code).
The FCP-500 is available as a photoelectric smoke detector or as a multi-sensor detector with an additional carbon monoxide (CO) sensor. The detectors are ideal for areas where increased levels of dust and fibers are expected. Each type is offered in white or transparent with color inserts.
The FCP-500 series smoke detectors satisfy the most demanding aesthetic requirements. Their ultra-low profile design offers flush ceiling mounting. The detectors and covers in the P versions are supplied with reversible printed color rings in 16 colors for individual color matching.
Functions
Sensor Technology and Signal Processing
All detectors in the FCP-500 series are equipped with two optical sensors and a contamination sensor. The
FCP-500-C multi-sensor detector also has a CO sensor.
All sensor signals are constantly analyzed by the internal signal electronics and are linked with each other through specially developed algorithms.
Linking the optical sensors and the CO sensor results in an extremely high tolerance to unwanted alarms.
Consequently, the detector can be used in places where the work carried out gives rise to small amounts of nonfire-related smoke, steam, or dust.
Optical (Smoke) Sensor (all models)
The optical sensor operates according to the scattered light method.
The LEDs transmit pulsed infrared light at a defined angle into the scattered light area. If a fire occurs, the light is scattered by the smoke particles and strikes the photo diodes that transform the quantity of light into a proportional electrical signal.
Interference effects from daylight and commercial lighting sources are filtered out with an optical daylight filter and by using electronic filtering and rectification algorithms.
The detector's various diodes (light-emitting and photo) are individually controlled by the detector's electronics.
Independent signal combinations are produced that are ideal for detecting smoke, making it possible to differentiate between smoke and interference agents
(insects, objects). In addition, the detector's programming checks the plausibility of the timing and correlation of sensor signals making it possible to detect errors in the analysis electronics or the LEDs.
www.boschsecurity.com
2 | FCP-500 Conventional Flush-mount Smoke Detectors
CO sensor (C models only)
Note The CO sensor is for detection enhancement only. It is not a CO detector and cannot activate an alarm in the presence of CO only.
Without the presence of CO, the smoke sensor is half as sensitive to smoke as a standard commercial photoelectric smoke detector. This reduces false alarms. When the sensor detects CO, the detection chamber's sensitivity to smoke increases so it is equal to that of a standard commercial photoelectric smoke chamber.
The CO sensor is monitored by measuring the current generated by CO oxidation on an electrode. If the current lies outside the permitted range, the trouble relay activates. If this occurs, the detector continues to operate only as a scattered light detector.
Contamination Sensor (all models)
The degree of contamination on the detector surface is continually measured by the contamination sensor.
Heavy contamination of the detector surface causes a fault indication.
Additional Performance Features
• A clearly visible two-color LED indicates various operating states:
A green LED flashes every 8 seconds when the detector has power and the smoke sampling circuitry is working.
A green double flash every 8 seconds indicates a trouble.
A green flash every second indicates that the detector is in test mode. This test mode, that checks the physical function of the optical sensor and the CO sensor, starts by activating the detectors dry reed contact with a magnet for at least 2 sec but not more than 4 sec.
• Perform an electrical function test by activating the dry reed contact for more than 10 sec. The detector activates an alarm and the LED turns red.
• An external alarm LED indicator can be connected.
• The innovative detector lock operates on a click and lock principle to provide fast and simple insertion and replacement of the detector. Use the specially developed FAA-500-RTL Removal Tool, especially for high mounting heights.
• Convenient detector testing is available with the
FAA-500-TTL Test Adapter with Magnet.
Certifications and Approvals
Listings and
Approvals:
UL URRQ: Smoke - Automatic Fire Detectors (UL268)
CSFM 7272-1615: 221
NYC/MEA (117-05-4, Vol. 2)
Installation/Configuration Notes
• Refer to the FCP-500 Series Installation Guide (P/
N: 610F.01U.000.626) for detailed instructions.
• Compatible with all UL Listed four-wire control panels. Refer to the manufacturer's installation instructions for proper EOL resistor selection. The
EOL resistor can be connected to terminals in the
FCA-500-E base
• Install the detectors exclusively in the FCA-500 or
FCA-500-E bases provided. In addition, install the detector base in an FAA-500-BB-UL ceiling-mount back box.
• Do not use FCP-500 detectors outdoors.
• Maintain an unobstructed hemispherical space with a radius of 1.6 ft (49 cm) below the detector.
• Ensure that people, larger animals, plants, or other objects do not intrude into this hemispherical area and that no parts of the detector surface become covered.
• Install the detector in a position which is out of arm's reach. A minimum mounting height of 8.8 ft (2.7 m) is recommended.
• Do not install FCP500 detectors in rooms where data is transmitted by means of high-intensity infra-red light (such as rooms with IR systems for interpreters).
• Do not mount the detectors in direct sunlight.
• Maintain a minimum distance of 1.6 ft (49 cm) from lamps. Do not mount the detectors in a cone of light from lamps.
• Consult NFPA 72 for proper detector placement. Use the specifications of a standard spot smoke detector.
A half-inch conduit connector can be mounted to the back box.
Parts Included
The FCP Series products are available individually or in kits. The kits contain:
1
1
1
FCP-500-K
Quant.
1
Component
FCP-500 Four-wire Detector Head (white)
FAA-500-BB-UL Flush-mount Back Box
FCA-500 Four-wire Detector Base
FAA-500-TR-W Trim Ring (white)
1
1
1
16
FCP-500-PK
Quant.
1
Component
FCP-500-P Four-wire Detector Head (transparent)
FAA-500-BB-UL Flush-mount Back Box
FCA-500 Four-wire Detector Base
FAA-500-TR-P Trim Ring (transparent)
Color insert rings
1
1
1
1
FCP-500-EK
Quant.
Component
FCP-500 Four-wire Detector Head (white)
FAA-500-BB-UL Flush-mount Back Box
FCA-500-E Four-wire EOL Detector Base
FAA-500-TR-W Trim Ring (white)
1
1
16
1
1
FCP-500-EPK
Quant.
Component
FCP-500-P Four-wire Detector Head (transparent)
FAA-500-BB-UL Flush-mount Back Box
FCA-500-E Four-wire EOL Detector Base
FAA-500-TR-P Trim Ring (transparent)
Color insert rings
1
1
1
1
FCP-500-CK
Quant.
Component
FCP-500-C Four-wire Detector Head with CO Sensor (white)
FAA-500-BB-UL Flush-mount Back Box
FCA-500 Four-wire Detector Base
FAA-500-TR-W Trim Ring (white)
1
1
16
1
1
FCP-500-CPK
Quant.
Component
FCP-500-C-P Four-wire Detector Head with CO Sensor (transparent)
FAA-500-BB-UL Flush-mount Back Box
FCA-500 Four-wire Detector Base
FAA-500-TR-P Trim Ring (transparent)
Color insert rings
1
1
1
FCP-500-CEK
Quant.
1
Component
FCP-500-C Four-wire Detector Head with CO Sensor (white)
FAA-500-BB-UL Flush-mount Back Box
FCA-500-E Four-wire EOL Detector Base
FAA-500-TR-W Trim Ring (white)
1
1
1
16
FCP-500-CEPK
Quant.
1
Component
FCP-500-C-P Four-wire Detector Head with CO Sensor (transparent)
FAA-500-BB-UL Flush-mount Back Box
FCA-500-E Four-wire EOL Detector Base
FAA-500-TR-P Trim Ring (transparent)
Color insert rings
FCP-500 Conventional Flush-mount Smoke Detectors | 3
Technical Specifications
Detection Principle
FCP-500(-P):
FCP-500-C(-P):
Scattered light measurement
Combination of scattered light measurement and CO measurement
Drift Compensation all FCP-500 detectors: Drift compensation for smoke sensor baseline
(optical sensors)
Drift compensation for CO sensor in addition, for FCP-500-C(-P):
Environmental Considerations
Air Speed
Humidity
Interference Immunity:
Operating Temperature
Protection Category:
Mechanical Properties
300 ft 3 /min (8.5 m 3 /min) maximum
95% (non-condensing)
According to UL 268
+32 °F to +100 °F
FAP-500(-C): IP 53
FAP-500(-C)-P: IP 33
Color:
Detector Housing:
Detector Front Plate:
Signal white, RAL 9003
FCP-500(-C): signal white
FCP-500(-C)-P: transparent (color inserts)
Dimensions (diameter x D)
Detector:
Detector with Trim Ring:
Detector with Trim Ring and
Base:
Material:
4.5 in. x 2.2 in. (11.4 cm x 5.6 cm)
5.9 in. x 2.2 in. (15 cm x 5.6 cm)
5.9 in. x 2.75 in. (15 cm x 7 cm)
Polycarbonate
Mounting Considerations
Area Monitored:
Mounting Height:
Refer to NFPA 72 Guideline
Maximum: Refer to NFPA 72 Guidelines
Minimum: 8.8 ft (2.7 m)
False Ceiling
Clearance (minimum):
Mounting Hole:
Thickness (maximum):
Outputs
6 in. (15.2 cm) with tolerances of -0.0625 in.
(1.6 mm) and +0.1875 in. (4.8 mm)
5.0625 in. (12.9 cm)
1.25 in. (3.2 cm)
Alarm
Output:
Relay Rating:
Reset Time
Alarm output through normally-open (NO) relay in FCA-
500 base. An alarm resistance of 0 Ω or 680 Ω in series to the relay can be adjusted.
1 A at 30 VDC
The detector resets if power is interrupted for at least
2 sec.
Display
Two-color LED: Red = alarm, green = test mode www.boschsecurity.com
4 | FCP-500 Conventional Flush-mount Smoke Detectors
Remote LED: Normally-open (NO) relay connects 0 V over 1.5 kΩ,
20 mA maximum
Trouble
Output:
Relay Rating:
Trouble output through normally-closed (NC) relay in
FCA-500 base
1 A at 30 VDC
Power Requirements
Current Consumption
FCA500 Base
FCA-500-E Base
Operating Voltage
Four-wire:
Alarm: 47 mA Standby: 3.5 mA
Alarm: 47 mA Standby: 24 mA
9.7 VDC to 33 VDC
Ordering Information
FCP-500-C Photoelectric with CO-Sensor (white) FCP-500-C
FCP-500-C-P Photoelectric with CO-Sensor (transparent with color inserts)
FCP-500 Photoelectric (white)
FCP-500-P Photoelectric (transparent with color inserts)
FCP-500-K Four-wire Kit (white)
FCP-500-C-P
FCP-500
FCP-500-P
FCP-500-PK Four-wire Kit (transparent with color inserts)
FCP-500-EK Four-wire EOL Kit (white)
FCP-500-K
FCP-500-PK
FCP-500-EPK Four-wire EOL Kit (transparent with color inserts)
FCP-500-EK
FCP-500-EPK
FCP-500-CK Four-wire with CO Sensor Kit (white) FCP-500-CK
FCP-500-CPK Four-wire with CO-Sensor Kit (transparent with color inserts)
FCP-500-CPK
FCP-500-CEK Four-wire EOL with CO-Sensor Kit
(white)
FCP-500-CEK
FCP-500-CEPK FCP-500-CEPK Four-wire EOL with CO-Sensor Kit
(transparent with color inserts)
Hardware Accessories
FAA-500-BB-UL Ceiling-mount Back Box for US FAA-500-BB-UL
FCA-500 Four-wire Base
FCA-500-E Four-wire Base EOL Base
FAA-500-RTL Removal Tool
FAA-500-TTL Test Adapter with Magnet
DRA-5 Remote Alarm Indicator
FCA-500
FCA-500-E
FAA-500-RTL
FAA-500-TTL
DRA-5
Americas:
Bosch Security Systems
130 Perinton Parkway
Fairport, New York, 14450, USA
Phone: +1 585 223 4060
Fax: +1 800 289 0096 [email protected]
www.boschsecurity.us
Europe, Middle East, Africa:
Bosch Security Systems B.V.
P.O. Box 80002
5600 JB Eindhoven, The Netherlands
Phone: +31 40 27 83955
Fax: +31 40 27 86668 [email protected]
www.boschsecurity.com
© Bosch Security Systems 2006 | Data subject to change without notice
F2098153227 | Cur: en-US, V3, 25 Jan 2006
Asia-Pacific:
Bosch Security Systems Pte Ltd
38C Jalan Pemimpin
Singapore 577180
Phone: +65 6319 3450
Fax: +65 6319 3499 [email protected]
www.boschsecurity.com
Represented by
Advertisement