BP25P3BC Tech Sheet - Balboa Water Group

BP25P3BC Tech Sheet - Balboa Water Group
BP501G3 Tech Sheet
Customer:
Balboa Water Group
Part Number:
56582
56583
56584
Custom Box Overlay
□
800 Incoloy
825 Incoloy
Titanium
Box Overlay Part Number N/A
UL System Model:
BP501-BP501G3-AU
Software Version ID:
M100_201 V20.0
Software Version:
20.0
File Name:
BP501_20.0_BP501G3.hex
Configuration Signature:
6E1DFB0E
Eng. Project Number:
4195
Base PCBA:
56585
Control Panels (See later pages for more information):
TP800
Version 3.1 and later (Version 3.13 or later required for bba™)
TP600
Version 2.7 and later (TP600CE may be used)
TP400T
Version 2.7 and later
TP400W
Version 2.7 and later
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
1
56582/56583/565984_97_A 02-05-14
System Revision History
Part #
EPN
Date
Originator Changes Made
56582
56583
56584
4195
01-15-14
BWG
BP501G3 initial draft. Adds GFCI Trip (but not GFCI Automatic Test). Updated to latest software version, adding topside-intergrated bba™ support.
bba™ (Balboa Bluetooth Amp) connection is documented seperately.
bba™ is only integrated into graphic display panels (TP800, TP900 and spaTouch™). With TP600 the Aux button operation of bba™ must be used.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
2
56582/56583/565984_97_A 02-05-14
Basic Functions Setup 1 - 8
Power Requirements:
240VAC, 50/60Hz*, 48A, Class A GFCI-protected service (Circuit Breaker = 60A max.),
4 wires [hot, hot, neutral, ground]
120/240VAC, 50/60Hz*, 16/40A, Class A GFCI-protected service (Circuit Breaker = 20 /50A max.) - Setup 8 ONLY,
3 or 4 wires [hot, hot (optional), neutral, ground].
*BP systems automatically detect 50Hz vs 60Hz.
System Ouputs:
Pump 1
240VAC*
2-Speed
10A max
15-minute timer
This is the heater pump
Must deliver 20 GPM through heater
Pump 2
240VAC
2-Speed
10A max
15-minute timer
1-Speed in Setups 3, 4, & 7
Unused in Setups 6 & 8
Pump 3
240VAC
1-Speed
10A max
15-minute timer
Used in Setups 1 & 3 only
Blower
240VAC
Ozone
240VAC*
Spa Light
10VAC
A/V (Stereo) 120VAC
Heater
1-Speed
4A max
15-minute timer
Used in Setups 2, 4, & 6
.5A max
Slaved to Pump 1 low
On/Off
1A max
240-minute timer.
Hot
4A max
Always on
5.5kW @ 240VAC max
*Pump 1 and Ozone must be the same voltage.
With 120VAC power input (for Setup 8 only), Pump 1 and Ozone must be set to 120VAC by moving wires attached to J50 and J51 to area 1 (Neutral).
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
3
56582/56583/565984_97_A 02-05-14
Hardware Setup
Wiring Diagram
BP501G3 PN 56582
MOVE WIRE TO CONNECT J2O TO J13 FOR BLOWER IN SETUPS 2, 4, & 6
J5 (A1-A4)
AUX
02-05-14
F2 3A 250V
12VAC-B
J19
12VAC-A
J18
K7
J100
J101
J108
J45
SENSOR A
5.5 kW HEATER
W1
TORQUE RANGE FOR HEATER
CONNECTIONS: 30 TO 35 IN. LBS.
PUMP 2
EXPANDER
X-P332
J1
VOLTS
240V
AMPS
10A
MAX
J29
VAC
HTR
DISBL
RIGHT
EXPANDER
BOARD
GFCI
J7
J6
TO
GROUP 3
J34
OFF
ON
A3
A2
FROM
J6 ON
EXPANDER
TO
J56
4
WHT
BLK
GRN
1
TEST MODE ON
ADD 1 HS PUMP WITH HEAT
ADD 2 HS PUMPS WITH HEAT
5 MIN HTR COOLDOWN (GAS)
SPECIAL AMPERAGE RULE ON
MEMORY RESET*
2
WHEN SYSTEM IS CONFIGURED AS 120VAC.
ADDED JUMPER FOR
120VAC SYSTEM
(1.25kW @ 120VAC HEATER)
REMOVE FOR 240V HEATER
CONFIGURED WITH 120VAC POWER INPUT/GFCI CORD (SETUP 8 ONLY).
56582/56583/565984_97_A 02-05-14
J43
J38 J37 J48
J35 J34 J36
**PUMP 1 AND OZONE MUST BE WIRED TO 120VAC WHEN SYSTEM IS
J50 AND J51 MUST BE CONNECTED TO AREA 1 (NEUTRAL)
1
3
3
SWITCHES #2 & #3 SHOULD BE SET TO OFF
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
TB1
OPTIONAL 120VAC CONFIG
FOR SETUP 8
ONLY:
F1 30A
FROM
W1 ON
EXPANDER
ON POSITION
1
2
3
4
5
6
*SWITCH # 6 SHOULD BE SET TO OFF UPON FINAL INSTALLATION.
ALL UNUSED SWITCHES SHOULD BE OFF
J33
GND
DEVICE
2/1 SPD
PUMP 2
J5
J17
J22
J28 AUX FRZ
LOCATION
J1 ON RT
EXPANDER
J47
J16
EXPANDER
F4 3A 250V
J46
HEATER
A/V
J14
S1 SWITCH #
TEST MODE OFF
DON’T ADD 1 HS PUMP W/HTR
DON’T ADD 2 HS PUMPS W/HTR
1 MIN HTR COOLDOWN (ELEC)
SPECIAL AMPERAGE RULE OFF
STORE SETTINGS*
TEMP SENSORS
J23
SERIAL
SENSOR B
TORQUE RANGE FOR
MAIN TERMINAL BLOCK:
27-30 IN. LBS.
J24
J49
J21
J32
J8
OFF POSITION
USE COPPER CONDUCTORS ONLY.
EMPLOYER UNIQUEMENT
DES CONDUCTEURS DE CUIVRE.
#6 AWG MIN. WIRE= 90°
J50
J51
J109
K5
J52
AUX
WIFI
TRANSCEIVER
J33 OR J45
FOR SUPPLY CONNECTIONS,
USE CONDUCTORS SIZED ON THE
BASIS OF 60°C AMPACITY BUT
RATED MINIMUM OF 90°C.
J40
T1
P3/BLWR
J38 J37 J48
J35 J34 J36
J50
LIGHT J15
K12
J56
OZONE
J43
K3
J30
A DISCONNECTING MEANS MUST BE INSTALLED WITHIN SIGHT FROM
THE EQUIPMENT AND AT LEAST 5 FEET (1.52 M) FROM THE
INSIDE WALLS OF THE POOL, SPA, OR HOT TUB.
J54
K1
GRN
K4
120V
J31 J27
3
3
RED
120V
TP (MAIN) PANELS
J33 or J45
J42
J39
J41
J53
1
2
BLACK
J20
J44
J42
J39
J41
J53
1
WHITE
2
6
J25=HTR1 J26=HTR2
J27=HTR3 J30=TEST
J31=CE HTR SEL
J25 J26
K6
K2
240V
UNUSED
J54
TB1
J55
J40
J12
ON 1
J51
F5 30A
2
(UNFUSED)
S1
PUMP 1
J56
J57
F6 0.3A 250V
F3 10A 250V
BLOWER
J13
CONNECT ONLY TO CIRCUITS PROTECTED BY A CLASS A GFCI.
Setup Reference Table
Setup #
Circ Pump
Pump 1
Pump 2
Pump 3
Blower
Temp Scale
1
None
2-Speed
2-Speed
1-Speed
None
°F
2
None
2-Speed
2-Speed
None
1-Speed
°F
3
None
2-Speed
1-Speed
1-Speed
None
°F
4
None
2-Speed
1-Speed
None
1-Speed
°F
5
None
2-Speed
2-Speed
None
None
°F
6
None
2-Speed
None
None
1-Speed
°F
7
None
2-Speed
1-Speed
None
None
°F
8
None
2-Speed
None
None
None
°F
As shown on additional wiring diagram section:
INSTEAD OF SETUP #1,
THIS SYSTEM IS
CONFIGURED
IN SETUP #:
LOCATION
J8
J14
J14
J15
J21
J24
J47
J46
DEVICE
2-SP PUMP 1
1-SP PUMP 3
BLOWER OPT
SPA LIGHT
SETUP #
CIRC PUMP
PUMP 1
PUMP 2
PUMP 3
BLOWER
TEMP SCALE
1
2
3
4
5
6
7
8
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
2-SPEED
1-SPEED
1-SPEED
2-SPEED
NONE
1-SPEED
NONE
1-SPEED
NONE
1-SPEED
NONE
NONE
NONE
NONE
NONE
NONE
1-SPEED
NONE
1-SPEED
NONE
1-SPEED
NONE
NONE
°F
°F
°F
°F
°F
°F
°F
°F
VOLTS
240V**
240V
240V
10V
MAX AMPS
10A MAX
10A MAX
4A MAX
1A
OZONE
240V** 1A
OZONE LINE 1 CONNECTION
TV / AV
120V
2A
HEATER
240V
5.5 kW
FROM
J50
J32
J32
TO
J48-AREA 3
J36-AREA 3
J36-AREA 3
J51
J49
J37-AREA 3
J53-AREA 1
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
5
56582/56583/565984_97_A 02-05-14
System (and any replacement board)
is shipped in Setup 1
Changing Software Setups with TP800 / TP900 / spaTouch™ Menued Panel
Test Menu Access (S1, Switch 1 ON) Service Technician ONLY.
1
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the system is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
Software Setups
Under the TEST Menu, the Setup screen will allow changing the
Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
10
ON
S1
102°F
High Range
Set: 104°F
8:32 PM
Ozone
Filter 1
Spa
Shortcuts
Settings
Test
Ready in Rest Mode
Heating
Note: The Timeouts and Temp Limit
selections should NEVER be changed.
They are for safety agency testing
purposes only.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
6
56582/56583/565984_97_A 02-05-14
`
Test
Back
Setup
A/B Temps
Fault Log
Timeouts
Temp Limit
1 `
Off
`
Normal
Yes
Changing Software Setups with TP600/400
Test Menu Access (S1, Switch 1 ON) Service Technician ONLY.
DANGER! HIGH VOLTAGE WILL BE ACCESSIBLE! SERVICE TECHNICIAN ONLY!
While the system is running, move DIP Switch 1 (on S1 on the Main circuit board) to ON.
The system will enter Test Mode.
Moving DIP Switch 1 to OFF will exit Test Mode.
As soon as Switch #1 is placed
in the ON position, the temperature will show
“T” after it instead of F or C, indicating the
System is in Test Mode
Software Setups
Under the TEST Menu, the Setup screen will allow changing the Setup from 1 to any number established by the Manufacturer.
Changing the Setup may require wiring changes as well.
You will have 1 minute to complete the setup change after you manually exit Priming Mode. (Once familiar with the process,
the Setup change should take less than 15 seconds.)
When the panel displays RUN PMPS PURG AIR, press any Temperature button ONCE to exit Priming Mode.
You should see “---T” where the T indicates the system is in Test Mode.
READY
RANGE
Continued on Next Page.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
7
56582/56583/565984_97_A 02-05-14
1
ON
6
S1
Changing Software Setups with TP600/400 Continued
Again, You will have 1 minute to complete the setup change after you manually exit Priming Mode.
Immediately after exiting Priming Mode, press this sequence of buttons: Warm*, Light, Warm, Warm, Warm, Warm. Continue to press Warm until the diplay
shows the Setup Number (S-01, S-02, etc.) you want to switch to. When the correct setup number is showing, press Light once, and the system will reset,
using the newly-selected Setup from that point on.
THIS SYSTEM IS
CONFIGURED AS
SETUP #
Move DIP Switch 1 to the OFF position to take the spa out of Test Mode. °F or °C will replace °T.
Using a permanent marker, write the Setup number on the Setup label mounted inside the system lid (right). This is very important to any service
person in the future who may need to replace a circuit board or system and needs to change the Setup on a replacement part while in the field.
NOTE: Changing the Setup may require wiring changes as well - refer to the wiring diagram or wiring diagram addendum.
Main Screen
READY
RANGE FLTR1
SET
RANGE
Key
The System will reset and go into Priming Mode if the Light Button
is pressed while anything other than the current setup is flashing.
If there is no change to the Setup Number (S-01, S-02, etc.),
the display returns to the SETP screen.
While the Set Temperature is
still flashing, press Light
TEST will now appear in
the LCD first.
Indicates Flashing or Changing Segment
Indicates Alternating or Progressive Message - every 1/2 second
A temperature button, used for “Action”
Light or dedicated “Choose” button, depending on control panel configuration
Waiting time - varies depending on function
SET
SET
SET
Several Setups can
exist in in this string
A dash (--) indicates the current Setup.
SET
When set to ON, Panel will display
alternate readings from
Senor A and Sensor B
on Main Screen
SET
Displays Fault Log
or
SET
SET
SET
SET
Approx.
5 sec.
SET
or
SET
SET
Approx.
5 sec.
SET
SET
Main Screen
READY
RANGE FLTR1
*If the Control Panel does not have a Warm (Up) button, but
rather a single Temp button, use the Temp button in place
of the Warm button in the instruction above. (The flow chart
assumes a single Temperature Button.)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
8
56582/56583/565984_97_A 02-05-14
Equipment Expansion
Expansion Features
Control Connection
Default
Fuse
Relay 1/2 (J108)
2/1-Speed Pump 2
30A
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
9
56582/56583/565984_97_A 02-05-14
DIP Switch Functions
Fixed-fuction DIP Switches
1
A1
Test Mode (normally Off).
A2
In “ON” position, add one high-speed pump (or blower) with Heater.
A3
In “ON” position, add two high-speed pumps (or 1 HS Pump and Blower) with Heater.
A5
In “ON” position, enables Special Amperage Rule B. See Special Features section under Configuration Options for functionality with your system.
In “OFF” position, enables Special Amperage Rule A.
A6
Persistent memory reset (Used when the spa is powering up to restore factory settings as determined by software configuration).
6
S1
ON
A2 and A3 work in combination to determine the number of high-speed devices and blowers that can run before the heat is disabled. i.e. A2 and A3 in the ON position will
allow the heater to operate with up to 3 high-speed pumps (or two HS Pumps and Blower) running at the same time. Heat is disabled when the fourth high-speed pump or
blower is turned on.
Note: A2/A3 all off = No heat with any high-speed pump or blower.
Assignable DIP Switches
A4
In “ON” position, enables a 5-minute cooldown for some gas heaters (Cooling Time B).
In “OFF” position, enables a 1-minute cooldown for electric heaters (Cooling Time A).
Undesignated switches are not assigned a function.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
10
56582/56583/565984_97_A 02-05-14
Jumper Definitions
J109
GFCI Test/Trip Enable/Disable
Note:
J109
This feature must be enabled in software as well.
J30
Do Not Use
J31
Non Applicable on UL models
J31
(Used on CE models only)
J29
Heater Disable Switch Connection. If J29 is shorted by any means, the heater will not run until J29 is no longer shorted.
J29
If J29 is shorted during power-up “J29” will appear on the panel.
The message can be dismissed with a button press, and is the only control panel notification of J29 being shorted.
No message is displayed if J29 is shorted after power-up, but the heater will not run until J29 is no longer shorted.
J29 expects a switch closure (not a voltage) as the command signal.
In some areas, a local power company may offer discounts based on voluntary “power shedding” devices that may be installed in conjunction with the spa.
J25, J26, J27
Heater Type Settings.
Note:
J44
J27
Factory Configured do not change.
J25
Jumper on center two pins (230V) when no neutral wire is used (240V-dedicated).
Two Jumpers installed; one on left 2 pins and one on right 2 pins (115V) when neutral wire is used.
Warning!
Setting DIP switches or jumpers incorrectly may cause abnormal system behavior and/or damage to system components.
Refer to Switchbank illustration on Wiring Configuration page for correct settings for this system.
Contact Balboa if you require additional configuration pages added to this tech sheet.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
11
56582/56583/565984_97_A 02-05-14
J44
J26
230V
115V
115V
BP501 Configuration Options
General Features
Feature
Default
Pump 1 in Filter Cycle (Circ Only)
No
Pump 1 Low Timer
30 Minutes
General Pump Timer
15 Minutes
Blower Timer
15 Minutes
Mister Timer
15 Minutes
Light Timer
240 Minutes
Circ (when enabled)
Programmable + Polling
Applies in non-circ Setups (configurations) only
Circ Pump can be set with the following functions:
24 hr – 24 hr w/3° shutoff – Acts like P1 Low (filters, polls, etc. - Requires a single-speed P1)
Cleanup Cycle
30 Minutes
Between 30 and 240 minutes
- or OFF
30 Minutes
Cleaup as Preference setting
Yes
Yes, No
N/A
Ozone
With Heater Pump*
Always, Filters/Cleanup Only
N/A
Ozone Suppression
OFF
Between 30 and 120 min.
- or OFF
1 Minute
Pump Purge
60 Seconds
Between 30 and 600 seconds
5 Seconds
Blower Purge
30 Seconds
Between 5 and 300 seconds
5 Seconds
Mister Purge
5 Seconds
Purge Type
Serial - Pumps at lowest speed
* The heater Pump can be either a Circ Pump or Pump 1 Low.
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
12
56582/56583/565984_97_A 02-05-14
BP501 Configuration Options
Temperature Features
Feature
Default
Temperature Display
°F
Options
Increment
°C, °F
All temperatures must be specified in °F. The system converts °F to °C dynamically. If Celsius is required for default settings, choose a desired °C value that (after rounding) corresponds to a Fahrenheit value.
°C
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
°F
39
41
43
45
46
48
50
52
54
55
57
59
61
63
64
66
68
70
72
°C
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
°F
73
75
77
79
81
82
84
86
88
90
91
93
95
97
99 100 102 104
Hi-Range Min. Set Temp
80°F
Between 50 and 80°F
1°F
Hi-Range Max. Set Temp
104°F
Between 60 and 104°F
1°F
Hi-Range Default Temp*
100°F
Between 50 and 104°F
1°F
Lo-Range Min. Set Temp
50°F
Between 50 and 80°F
1°F
Lo-Range Max. Set Temp
99°F
Between 60 and 99°F
1°F
Lo-Range Default Temp*
70°F
Between 50 and 99°F
1°F
Freeze Threshold
44°F
Freeze Type
Rotating - Pumps at Lowest Speed
Temp Lock Type
Temp + Settings
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
13
56582/56583/565984_97_A 02-05-14
BP501 Configuration Options
Time Features
Feature
Default
Options
Increment
Time Format*
12 Hour
12 Hour, 24 Hour
N/A
Filter 1 Start Hour*
20:00 (8:00 PM)
00:00 to 23:00
1 Hour
Filter 1 Duration*
2 Hours
Between 15 Min and 23:45
-or continuous
15 Minutes
Filter Cycle 2 Default*
OFF
OFF, ON
N/A
Filter 2 Start Hour*
08:00 (8:00 AM)
00:00 to 23:00
1 Hour
Filter 2 Duration*
15 Minutes
Between 15 Min and 23:45
-or Continuous, or Disabled
15 Minutes
Light Cycle
Disabled
Disabled, Enabled
N/A
Light Cycle Default*
OFF
OFF, ON
N/A
Light Cycle Start Hour*
21:00 (9:00 PM)
00:00 to 23:00
1 Hour
Light Cycle Duration*
15 Minutes
Between 15 Min and 04:00
-or or Disabled
15 Minutes
Cooling Time A
1 Minute
Cooling Time B
5 Minutes
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
14
56582/56583/565984_97_A 02-05-14
BP501 Configuration Options
Reminder Features
Feature
Default
Reminders Shown*
Yes
Yes, No
N/A
Check pH
OFF
See Reminder Period Note
1 Days
Check Sanitizer
OFF
See Reminder Period Note
1 Days
Clean Filter
30 Days
Test GFCI
65 Days
See Reminder Period Note
1 Days
Drain Water
100 Days
See Reminder Period Note
1 Days
Change Cartridge
OFF
Clean Cover
OFF
See Reminder Period Note
1 Days
Treat Wood
OFF
See Reminder Period Note
1 Days
Change Filter
365 Days
Options
Increment
See Reminder Period Note
See Reminder Period Note
See Reminder Period Note
1 Days
1 Days
1 Days
Reminder Periods can be set between 7 and 180 days. In addition, 365 days can be chosen.
Each reminder can be turned OFF individually.
*May be changed by end-user (if enabled)
Blue Indicates New Custom Configuration Default (Setup 1)
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
15
56582/56583/565984_97_A 02-05-14
BP501 Configuration Options
Special Features
Feature
Default
Special Amperage Rule A
No Limitation
1 Pump
Special Amperage Rule B
No Limitation
1 Pump
Options
Increment
1 to 7 pumps can run on high speed together.
Blower can be allowed or suppressed when number of pumps selected is reached.
“No Limitation” does not restrict pump or blower operation.
DIP Switch 5 is used to choose Special Amperage Rule 1 or 2.
Drain Mode
Disabled
Demo Mode
Disabled
GFCI Trip
Enabled
Disabled, Enabled
N/A
Disabled, Enabled
N/A
Automatic GFCI Test
Disabled
Disabled, 1-7 Days
When GFCI Test is Enabled, the Auto-Test can be set between 1 and 7 days from startup
Ozone Slaved to Heater Pump
1 Day
Yes
Yes, No
N/A
Dual Voltage Heater
Always Input Voltage
4°F Temperature Delta
N/A
Safety Suction
Disabled
Disabled, Enabled
N/A
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
16
56582/56583/565984_97_A 02-05-14
TP800 Panel Configuration
Button Layout Table
Feature
#
Setups 1 & 3
Setups 2 & 4
Setups 5 & 7
Setup 6
Setup 8
A1
N/A
N/A
N/A
N/A
N/A
A2
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
A3
Jets 2
Jets 2
Jets 2
Blower
Light 1
A4
Jets 3
Blower
Light 1
Light 1
Invert
A5
Light 1
Light 1
Invert
Invert
Undefined
A6
Invert
Invert
Undefined
Undefined
Undefined
A7
Undefined
Undefined
Undefined
Undefined
Undefined
A8
Undefined
Undefined
Undefined
Undefined
Undefined
A9
Undefined
Undefined
Undefined
Undefined
Undefined
A10
Undefined
Undefined
Undefined
Undefined
Undefined
A11
N/A
N/A
N/A
N/A
N/A
A12
N/A
N/A
N/A
N/A
N/A
A13
Undefined
Undefined
Undefined
Undefined
Undefined
A14
Undefined
Undefined
Undefined
Undefined
Undefined
A15
Undefined
Undefined
Undefined
Undefined
Undefined
A16
Undefined
Undefined
Undefined
Undefined
Undefined
B1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
B2
Jets 2
Jets 2
Jets 2
Blower
Undefined
B3
Jets 3
Blower
Undefined
Undefined
Undefined
B4
Light 1
Light 1
Light 1
Light 1
Light 1
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
17
56582/56583/565984_97_A 02-05-14
TP800 Panel Configuration
Spa Screen
B1
A6
B2
A2
A3
A4
A5
A7
A8
A9
A10
B3
B4
Shortcuts Screen
A13
B1
A13
A14
B2
B3
A15
A14
A16
A15
B4
A16
Note: Buttons 11 and 12 are
not used in this configuration.
Button 1 is fixed.
Panel Part Number
50204-05
Overlay Part Number
N/A
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
18
56582/56583/565984_97_A 02-05-14
TP600 Panel Configuration
Button Layout Table
Button
#
Setups 5 & 7
Setup 6
Setup 8
Setups 1 & 3
Setups 2 & 4
1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
2
Jets 2
Blower
Undefined
Jets 2
Jets 2
3
Invert
Invert
Invert
Jets 3
Blower
4
Up
Up
Up
Up
Up
5
Light 1
Light 1
Light 1
Light 1
Light 1
6
Down
Down
Down
Down
Down
LED 1
Jets 1
Jets 1
Jets 1
Jets 1
Jets 1
LED 2
Jets 2
Blower
Undefined
Jets 2
Jets 2
LED 3
Light 1
Light 1
Light 1
Light 1
Light 1
LED 4
Heat On
Heat On
Heat On
Heat On
Heat On
1
4
4
1
TP600
2
2
5
READY
3
5
55676-07
RANGE FLTR1
3
6
1 2
3 4
1 2
3 4
No Overaly
6
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
19
56582/56583/565984_97_A 02-05-14
TP400 Panel Configuration
Button Layout Table for TP400T
Button
#
Setups 5 & 7
Setup 6
Setup 8
1
Temperature
Temperature
Temperature
2
Jets 1
Jets 1
Jets 1
3
Light 1
Light 1
Light 1
4
Jets 2
Blower
Undefined
LED 1
Heater ON
Heater ON
Heater ON
LED 2
Jets 1 ON
Jets 1 ON
Jets 1 ON
LED 3
Light ON
Light ON
Light ON
LED 4
Jets 2 ON
Blower ON
Undefined
1
2
3
4
1
2
3
4
1
2
3
4
1
2
3
4
TP400T
TP400T is not supported in Setups 1-4 (that have either Pump 3 or both
Pump 2 and Blower).
50260-02 or later
Includes overlay PN 12511.
Button Layout Table for TP400W
Button
#
All Setups
1
Up
2
Down
3
Light 1
4
Jets 1
LED 1
Heater ON
LED 2
Undefined
LED 3
Light ON
LED 4
Jets 1 ON
Use the TP400W for setups that only have
one pump (No Blower or Pump 2 or Pump 3).
TP400W
50259-01 or later
Includes overlay PN 12510.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
20
56582/56583/565984_97_A 02-05-14
BP501 Configuration Options
Auxilliary Panel Features on Bank 1*
Feature
Default
Aux Button A1
Jets 1
Aux Button A2
Jets 2
Aux Button A3
Jets 3 in Setups 1 & 3
Blower in Setups 2, 4 & 6
Undefined in Setups 5, 7 & 8
Aux Button A4
Light
*Bank 1 consists of J5 on the Main Circuit Board.
Aux Connection Splitter PN25257 may be required.
Buttons that are assigned to equipment that is
not defined in a Setup will not do anything in that Setup.
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
21
56582/56583/565984_97_A 02-05-14
BP501 Configuration Options
Auxilliary Panel Features
AX10 Panels on Bank 1*
A1, AX10A1
No O/L
52803
A2, AX10A2
No O/L
52804
A3, AX10A3
No O/L
55805 A4, AX10A4
No O/L
52806
Call Customer Service for
additional information about Auxiliary Panels.
Blower
Jets 1
Auxiliary Panel Part Number _____________________
Overlay Part Number
_____________________
*Bank 1 consists of J5 on the Main Circuit Board.
Aux Connection Splitter PN25257 may be required.
AX20
AX20 A1A2
No O/L
52800
AX20 A1A3
No O/L
52801
AX20 A1A4
No O/L
52802
AX20 Auxiliary Panel plugged into Bank 1 will operate A1 + A2, A3 or A4.
A2, 3 or 4
A1
AX40
AX40
AX40 Auxiliary Panel plugged into Bank 1 will operate A1 + A2, A3 and A4.
No O/L
52799
A1
A2
A3
A4
Manufactured under one or more of these patents. U.S. Patents: 5332944, 5361215, 5550753, 5559720, 5,883,459, 6253227, 6282370, 6590188, 6976052, 6965815, 7030343, 7,417,834 b2,
Canadian Patent: 2342614, Australian patent: 2373248 other patents both foreign and domestic applied for and pending.
© Copyright 2014 Balboa Water Group.
Template 56377 10-05-12
22
56582/56583/565984_97_A 02-05-14
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement