Cabur Electronics Catalogue


Add to my manuals
160 Pages

advertisement

Cabur Electronics Catalogue | Manualzz
Electronic
Products
for electrical
panels
2014 edition
UNI EN-ISO 9001
UNI EN-ISO 14001
Cover: Trasparenze Srl - Milano
Design, layout and illustrations: Looping Srl - Savona
2
WARNING If not specified, the technical data in this catalogue are typical and measured at 25°C (77°F), 230 Vac, Unom, Vdc and rated
current; ripple is measured at 20 MHz with probe connected to 0.1 μF. The technical data in this catalogue are typical and are not binding
for Cabur and may be modified without prior notice, simply for production or improvement and/or evolution reason. Please contact
our technical-commercial offices for any relevant confirmation or updates. For more informations visit our web site www.cabur.eu.
3
Introduction
Cabur . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Products range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Web site . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Quality and environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Standards and Directives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
6
8
9
10
11
Power supplies
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSD series - modular single-phase switching power supply - Domotic Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSF series - single-phase switching power supply - Cool Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Single-phase switching power supply in IP65 housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSL series - single-phase switching power supply - Easy Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSW series - 1-2-3-phase switching power supply - Universal Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSG series - 3-phase switching power supply - Triple Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSA series - DC/DC switching converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Power supply with 24 Vac input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Battery charger DC-UPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Batteries holder module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CSC series - switching power supply with integrated battery charger . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Accessory for power supplies redundant parallel connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Motor brake controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
12
14
16
21
29
30
35
39
46
49
53
56
57
58
60
Surge protection devices
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Pluggable surge protection devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
62
64
Overcurrent protection devices
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Adjustable electronic overcurrent protection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
65
66
EMI Filters
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
TDV series - 3-phase filter without neutral. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
TDS series - 3-phase filter without neutral. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
TDDS series - 3-phase filter without neutral. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
TDSS series - 3-phase filter without neutral. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
TYT series - 3-phase filter with neutral . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
TY series - compact three-phase filter with neutral. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
DK series - single-cell single-phase filter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
DP series - double-cell single-phase filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
67
68
69
70
71
72
73
74
75
Signal conditioners
Introduction
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Quick selection table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Programmable analog signal converters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Analog signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Passive galvanic isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Analog signal to threshold converter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Universal temperature converters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Temperature to threshold converter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Programmable converters for RTD sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page
Programmable converters for TC J and K sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Current to threshold converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Current to analog signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
4
76
78
81
84
87
88
89
90
91
92
93
94
Frequency to analog signal converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Auxiliary power supply for sensors and potentiometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
NPN and PNP signal inverter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
97
98
99
Electromechanical relay modules
Single relay quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
R series - single relay DC input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CM series - single relay DC input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CM series - single relay AC input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CKR and CWRE series - Relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Multiple relays quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
24 V SPDT multiple relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
24 V DPDT multiple relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
24 V SPDT multiple relay modules with test button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
110...120 V SPDT multiple relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
230 Vac SPDT multiple relay modules
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CR and CRE series - super compact relay modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
PLC and CN interfaces quick selection table for . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
PLC Siemens S7 interfaces modules
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
PLC Telemecanique interfaces modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
100
101
103
106
108
111
112
116
119
120
121
122
124
125
128
Solid state relay modules
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Single solid state relays modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CKS series - modular single solid state relays modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
SPDT single solid state relays modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Signal optoisolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Multiple solid state relays modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
129
130
133
135
136
137
Passive interface modules
Quick selection table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
SUB-D / terminals interfaces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
FLAT-cable / terminals interfaces
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CCM series - components holder modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CDM series - diodes holder modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CLT series - LED testing module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
CLP series - lamp testing module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
141
142
145
147
148
150
151
Accessories
Electronic circuit housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Plug-in and screw type jumpers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Marking system
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
DIN rail clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
Mounting rails . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
152
154
154
156
157
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page
159
5
• Terminal blocks for electrical boards
Terminal blocks for electrical panels, polyamide screw-clamp and spring-clamp terminal blocks, control terminal boards,
high-current terminal boards, mobile terminal blocks, distribution terminal boards, 12-pole polyamide terminal boards
• Electronic products for electrical boards
power supplies, analog modules, relay modules, signal converters
• Connection systems for photovoltaic plants
Connectors, tools, cables, brackets for mounting of photovoltaic panels, string boxes, control units, monitoring systems,
surge protection devices, diodes, fuse-holders
• Industrial marking systems
printing systems, tags and accessories for wire and terminal block identification, tags for contactors and buttons, modular
strips for distribution panels, panel identification tags, labels and signboards
If you wish to receive complete and updated technical documentation on Cabur
products, please send a request using the dedicated form that you can download
online on the www.cabur.eu website
h t t p : / / w w w. c a b u r. e u / d o c u m e n t a t i o n s
or just fill in, and send the form below
PLEASE SEND ME THE COMPREHENSIVE TECHNICAL DOCUMENTATION
Surname
Name
Function
Field of activity: R Distributor R Installer RPanel Builder R Other
Company Name
Address
Telephone
Town
Fax
Postcode
E-mail
The data provided will be stored and used by Cabur srl in both paper and electronic form, both directly and through a reliable service provider, safely and with attention to privacy. At any time, you may exercise your rights
pursuant to Italian Legislative Decree no. 196/2003, by writing to the data manager at the following address: Cabur srl, with offices in Altare (SV), Località Isola Grande 45 - Italy. I authorize the use of my data in accordance
with Italian Legislative Decree no. 196/2003, as amended, for:
• The provision of goods and services (necessary to send documentation)
YES
NO
• Statistical profiles and processing
YES
NO
• Sending commercial communications
YES
NO
• Communication of data to agencies and partner companies
YES
NO
I agree to my personal data being processed for the a.m. purposes.
Signature
PLEASE PHOTOCOPY AND SEND BY FAX AT
+39 019 58999280
Date
6
1952
2014
S
hortly after its foundation, back in 1952, Cabur became a leading manufacturer of electrical panel
terminal blocks, by focusing on installers’ needs and providing leading edge technical solutions
that, in some cases, would become popular in the industry.
In particular, in our product design and manufacturing, we have pioneered a quality focus on raw
materials, functionality, reliability over time, and respect for the environment. That is the reason why
Cabur was granted Class 1E (Equipment for Nuclear Power Generating Stations) qualification as early
as in 1985 and, in addition, the ISO 9001/UNI-EN 29001 (Quality) and ISO 14001 (Environment)
certifications, as well as compliance to Atex standards for “Ex e” installations on the most important
terminal block lines. The quality of Cabur products and services has been aknowledged by several
international certification institutes.
UNI EN-ISO 14001
The headquarter
UNI EN-ISO 9001
I
n 2006 Cabur invested in an advanced 15.000 sqm production site in Altare (SV). By doubling the
production surface and increasing the staff with the recruitment of new people enabled the company
to to rationalise the production processes, logistics, and sales, and increase their efficiency.
Cabur develops and produces a wide range of products for the electric and electronic industry, based
on its own projects, which are well known for their reliability even in extrem deployment conditions and
are produced to satisfy the various and complex needs of installator and end users.
Località Isola Grande 45
17041 Altare (SV)
ITALY
Tel. +39 019 58999.1
Fax +39 019 58999280
e-mail: [email protected]
Exit at the toll gate of Altare on the
A6 Savona-Turin motorway
At the roundabout, follow traffic signs
to Industrial Zone and Mallare
Milan
Pass under the railway bridge
A6
Genoa
Savona
SP29
After 2.5 Km you will find us on your
left
A6
A6
SP5
SP29
Altare
Ventimiglia
A6
7
Direction Savona
Exit A6 Altare
Direction Turin
Turin
W
ith over 60 years of experience, Cabur develops and produces,
by its own designs, a wide range of products for the electrical
industry, providing the best in working conditions, in terms of
operability and reliability.
Current production of:
• Terminal blocks for electrical boards
• Electronic products for electrical boards
• Installation products
• Products for photovoltaic installations
• Industrial marking systems
Fully meets users’ varied and complex installation needs.
Our varied and diversified production represents the optimal synthesis of
Cabur’s long experience as partner of Italy’s most important Industries and
Research Laboratories, combined with foreign activities and collaboration,
always with the aim of pinpointing and meeting users’ installation needs.
I
n particular as a result of a specific planning decision, products in our
“standard” series are designed to meet the fundamental requirements
of the most severe installation conditions and environments, thus
avoiding to produce special product series for specific applications. This
kind of planning has determined a clear qualitative improvement in the
entire production, as well as a more streamlined and simplified product
management, first of all to the advantage of the Distribution, which can
guarantee to final Clients the most efficient service.
I
n addition to terminal blocks, Cabur product offering features a full range
of electronic products for electric panels for plant and machine automation
and process control. These products are designed for an easy deploy and
for easy material management, thanks to the use of innovative and leadingedge technology.
T
he line of products for industrial marking completes the range
with innovative printing solutions, labels for wires, terminal blocks
and buttons, tags and modular strips for distribution boards.
Highest ...
...mass produced quality
W
e guarantee top performance of our contacts and maximum flexibility
of connection solutions. A full range of standard products for
automation panels is available at all major Wholesalers. Full support is
provided by Cabur sales force both in Italy and in over 30 countries abroad,
as well as by our Engineers, in order to provide our clients with the best
installation solutions.
8
The new www.cabur.eu web site
O
n our web site, our customers and industry operators can always get
up-to-date information on new products and sales offers.
The data sheets of all Cabur products, including the items in this
catalogue, are available online in electronic format, with a completely
renewed data base structure, that can be consulted by its index or
queried with an advanced research engine.
.
Moreover, on our web site you can:
• ask our specialists for technical information and application advice
• contact our sales staff and ask them for estimates
• download manuals and other technical literature
• get access to quality and compliance certificates
• look at our latest sales literature
• ask for free catalogues and brochures
• … and much more.
By this newsletter, Cabur communicates also via e-mail its main
innovations and commercial activities to all those who apply for it through
the registration form.
In conclusion, Cabur web site (www.cabur.eu) is the ideal tool to get real
time information and contacts with our company.
www.cabur.eu
Real time information on
our company, products, and
certifications
In order to be promptly updated about the availability of new technical and commercial documentation, please register on the site and join the newsletter service.
9
ISO 9001 CSQ Certification
U
ntil recently, Cabur “Quality” was simply recognised through the appreciation
of its customers. This has allowed the company to become a leader in Italy
in the design, production and distribution of “terminal blocks for electrical panels”
and, more recently, to extend its products offering to the segment of “electronic
products” with recognised reliability levels in both Italian and foreign markets.
Obviously, this cannot be the result of improvisation, but of a constant organisation process begun back in 1985 with the definition and implementation of a
Quality Assurance Programme based on ANSI N 45.2 (referred to the particularly
severe nuclear environment) that has involved the entire structure of the Company
and has made each function and worker responsible for quality standards.
Since 1995, CSQ (international institute for the certification of business quality
systems) has certified the Quality system designed and adopted by Cabur.
The Quality system refers to the most complete and severe standard
amongst UNI EN ISO 9000 series defining the requirements for Total Quality
in Companies, that is ISO 9001, including the activities of Product Design,
Development, Manufacturing and Customer Service.
After the issue of the new Edition of the Standard (ISO 9001:2008), the whole
Quality System has been revised and renewed to be fully compliant with the
new regulations.
UNI EN-ISO 9001
ISO 14001 CSQ Certification
I
n its continuous improvement process, CABUR has adopted an environmental
management system since 2001, obtaining the international CSQ UNI EN
14001 recognition.
This goal represents a guarantee given of the respect Cabur has for the
surrounding environment as well as a demonstration of the adoption of
environmental safeguard rules and, additionally, a pledge for constant
ecological improvement.
This kind of Certification is still quite uncommon in Italy; Cabur has nevertheless
been able to achieve and add it to its corporate philosophy, which is always
aimed at the anticipation, rather than to the passive adaptation, of those
needs that are becoming more and more urgent and global. Environment is
undoubtedly one of these issues and, anticipating many other companies, not
only in Italy, Cabur firmly decided to adopt a system that monitors and prevents
environmental risk, inherent to every stage of its manufacturing process.
Operational procedures and other paper documentation were unified and
harmonised with the running Quality Assurance System and the manual,
becoming of both Quality and Environmental Management, is now a complete
reference point. The Quality Assurance and Environmental Management
Department is at your complete disposal to provide any further information and/
or clarification on the entire Quality / Environment System and Customer Service.
Cabur can provide you with a copy of both CSQ and EQNET certificates, or with
a copy of the Quality and Environmental Management manual.
UNI EN-ISO 14001
10
The 2011/65/CE Directive
Cabur Products’ compliance to RoHS Directive
D
irective 2011/65/CE, known as RoHS 2, sets limits to the use of specific
dangerous materials, listed in Annex II of the Directive, in electric and
electronic devices.
Products like terminal blocks and connectors are not considered electric or
electronic appliances; nevertheless, in consideration of the needs of those
Customers deploying these products into appliances and devices which are
subject to the Directive, Cabur has decided to review its production to make it
RoHS compliant.
The Directive applies exclusively to devices included in the following categories,
as listed in attachment 1, i.e.:
From 2006, with the introduction of the former 2002/95/CE Directive, we have
been disposing of non-compliant items, completely eliminating – wherever
possible – the dangerous material and substances listed in Annex II from
components in our production, with a Zero Tolerance mindset. Those materials
remain in limited quantity, well below the limits set by the Directive, only in those
components that cannot be efficiently and effectively produced with available
alternative technological solutions.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Large appliances
Small appliances
IT and telecommunication appliances
Consumers’ appliances
Lighting appliances
Electric and electronic tools.
Toys and devices for hobbies and sports
Medical devices
Monitors and control instruments, including industrial monitoring and
control instruments
10. Vending machines
11. Other electric and electronic devices not listed in the above categories
Further information and updates are always available on www.cabur.eu.
Our staff is available for further details both on our products and on the
application of the RoHS Directive.
Marking
Do not hesitate to contact our staff for any further information and/or
explanations on Reference Standards. Cabur Customer Service can provide
you with certificates of compliance to Reference Standards, type approvals,
and CE markings.
A
ll products in this catalogue meet all EU applicable standards when the
catalogue was printed. Therefore, all required CE markings are placed on
the products and on all product related documents.
11
C
ontinues to renew and expand its range of power supplies for use in industrial
automation and control of processes and systems, improving product performance
and technology to meet the needs created by the continuing changes in applications
and regulations.
With high power power supplies, which power various loads protected from
overcurrent, the capacity to provide overcurrent is indispensable to guarantee
selectivity in protection interventions. This is because it allows the fuse of the
malfunctioning load to be “burned” before the electronic protection of the power
supply intervenes, disconnecting the output and hence the entire system.
QUALITY AND SAFETY: Cabur was the first Italian company to obtain UL508 Industrial
Control Equipment certification for industrial automation processes and Hazardous
Location Class 1 Div. 2 for processes in dangerous areas, as well as to have been
certified as conforming to the Directives on Electric Safety. It also has been EMC
certified by an accredited laboratory. All of these are indispensable for the CE certified
label.
ELECTRONIC OVERLOAD POWER SUPPLY PROTECTION CAN BE OBTAINED USING
VARIOUS TECHNIQUES:
– switch off the output as soon as possible: this is cost effective but doesn’t allow for
either start up of heavy loads nor for protection selectivity for various loads.
– constant power protection: if the allowed overload is sufficiently high, it is possible
to start up heavy loads. However, if the condition continues, the power supply will
continue to operate in overload and with a high thermal stress level. Hiccup protection:
combines the advantages of the techniques described above, while limiting the
disadvantages because it allows over +50-100% of the overload for at least 5
seconds, and then switches off output for a longer break. In this way, the peak power
necessary for heavy load peaks is obtained while component heating is decreased,
as they can cool off during the break. Hiccup protection with high overcurrent output,
for durations from 200 ms to over 5 sec., has been proven to satisfy the new
requirements established by the Machinery Directive EN 60204-1.
Real operating temperature: the operating temperature range for all Cabur models is
between –20 and +50°C at full load without derating (see technical data), certified in
accordance with the rigorous UL508 standard. The project takes into consideration the
ambient temperature, allowed overcurrent, and overcurrent duration when determining
component size, and is always more than the 45°C required by the standards for
electric panels. Ambient temperature is a fundamental reference parameter, because
this influences not only performance, but also component operating temperature and
power supply duration.
INNOVATION AND RESEARCH:
• 1997 - Cabur is the first Italian company to produce switching power suppliers for
Din-rail with 90-264Vac/110-340Vdc universal input.
• 2001 - Cabur is the first Italian company to produce high efficiency power supplies
with resonant technology (the 20A three-phase dissipates only 36W compared with
over 75W for our competitors at the time).
• 2009 – With the new generation of power supplies in the catalogue, Cabur has further
improved performance using “Synchronous Rectifier" technology, which reduces
power dissipation and operating temperature to the minimum, an indispensible factor
in minimizing the size of the power supplies, which are the smallest on the market.
The lifespan of a power supply is halved by every +10°C increase in operating
temperature. Hence, reducing operating temperature is fundamental to endurance
and reliability, two objectives that can be achieved only by using circuit technology and
next generation components. Thanks to this combination, Cabur has achieved output
of over 94% (the new 20A three-phase dissipates only 28W, compared to the 50-75W
in heat dissipation found in other products currently on the market).
HIGH OVERLOAD CAPACITY: the new power supplies have an overload capacity of
over +50% for 5 seconds or for several minutes (please see the technical data), while
maintaining stable output voltage even under these conditions.
HOLD UP TIME: this is the time in which the power supply output supplies nominal
voltage at nominal load. This performance is important because it limits the cases in
which machine/system stoppage can occur due to voltage "holes" in the network.
EMC standards establish that Hold Up time must be at least 10ms. For all Cabur
power supplies, Hold Up time is greater than that required by the official standards,
which ensures better operational consistency in networks with frequent voltage holes.
SYSTEM COMMUNICATIONS: all the CSF, CSG, and CSW Series models are provided
with “intelligent” alarm contacts that commutate when the output voltage drops
below -10% of the nominal value. This allows the controls to activate automated or
emergency procedures to reduce machine stoppage, production losses, and the risk
to safety.
MTBF: this figure should be taken with a care, because it is the result of theoretical
calculations that are easy to manipulate. For example, if we know that the mortality
rate for 25 year old men is 0.1%/year, the resultant MTBF, calculated in accordance
with SN29500 – IEC 61709, would be 800 years. Obviously, this result is highly
unrealistic. The significant piece of information is the “life expectancy,” which for men
averages about 75 years – less spectacular but more realistic. The same reasoning
can be applied to electronic products for which, in accordance with the calculation
methods, we can use an MTBF of 750,000 hours (85 years), or a life expectancy of
about 70,000 hours (7.9 years, on average). The second estimate is less optimistic,
but is without doubt closer to reality. As a consequence, data published regarding
MTBF must be interpreted based on the credibility of the calculation methods used. In
addition to the values according to SN 29500, Cabur has also chosen to declare those
according to the MIL HDBKn217F standards, which are much stricter.
TOTAL PROTECTION: all models are provided with output protection against overload
short circuiting, overtemperature, and overvoltage, both for input and output. Input for
the three-phase models includes the Active Surge Suppressor – Inrush Current Limiter,
which avoids malfunctioning in the case of overvoltage generated by commutation of
loads or malfunctions on industrial networks, where the value can reach 3-4 times
the network voltage, with a duration of 1.3ms (Regulation VDE-0160), which can be
destructive for the input components. This increases reliability, especially in networks
subject to power surges and power malfunctions.
SHORT CIRCUIT and overload protection: this serves to protect the power supply from
malfunctions due to overloading and overheating of the components. This function can
be designed by starting with different application needs, with varying practical results
and costs. In automated applications, the operating conditions and the nature of the
loads can vary greatly and are only partially known to the power supply designer.
Power suppliers for automated processes need to meet a number of requirements.
They need to be protected from overcurrent, but at the same time they need to be able
to supply loads which call for a high peak current, working at temperatures of at least
45° C, according to regulations, and sometimes higher, in critical ventilation situations
and guaranteeing high reliability and acceptable costs.
The overcurrent protection must support the high peak currents required by loads such
as filament lamps (cold, they make a short circuit), capacitive loads such as dc/dc
converters and filter condensators (when these switch on they are seen as a short-circuit
for a few tenths of a ms) or inductive loads (engines in dc, electromagnets, etc.) which
at peak require currents from 5 – 30 times their nominal power. Frequently, all these
loads must be started up at the same time. The peak current must be provided for a
sufficient duration to “start” the load, which can go from a few tenths of a ms up to 5s.
CUSTOM POWER SUPPLIES: Cabur designs and produces “custom” power supplies
on request to meet the requirements of regulations and the high demanding
applications. Furthermore our laboratory offers technical documentation and the
measures which prove the conformity of the products with the directives on Electric
Safety and Electromagnetic Compatibility, besides the necessary technical support
to define the product characteristics on the basis of the client’s needs and our own
experience.
THE ENVIRONMENT AND ROHS CONFORMANCE: Cabur was one of the first Italian
companies to obtain the International Environmental Certificate UNI EN ISO 14001,
certified by CSQ for ecologically compatible treatment of all the materials used in our
production.
12
L
General Notes
+
+
AC
–
–
AC
+
AC
GND
PARALLEL AND REDUNDANT PARALLEL CONNECTION: all Cabur power supplies
can be connected in parallel to combine the power of two or more power supplies.
In addition, models that already include an output separation diode (ORing diode)
are available for use with redundant parallels (please see the related item in the
catalogue). We recommend adjusting the outputs of all the power supply units to
the same voltage (tolerance ± 50 mV), applying the same calibration load, before
connecting them in parallel. We also recommend using power supply units of the
same model. If it is necessary to connect two power supplies without internal diodes
in redundant parallel, the connection must be completed as in fig. 1.
CONNECTION IN SERIES: all Cabur power supplies can have their outputs connected
in series to double the voltage (see fig. 2) or to obtain dual voltage output, for example
with ± 12V or ±24 V (see fig. 3). We recommend that you use power supplies of the
same model and an anti-parallel diode, of an appropriate size to resist the maximum
current of the power supply.
N
GND
L
AC
–
AC
+
GND
POWER SIGNAL OK: this is found on all CSF, CSG, and CWS models. The 1A/30Vdc
contact commutates when output voltage falls below the threshold of -10% of nominal
voltage, in the case of a short circuit on the output line or an overload that exceeds the
specifications, or due to network failure.
N
figure 1
+
V
–
AC
V+V
+
AC
V
GND
100-340Vdc POWER SUPPLY: available for certain models (please see technical data),
which respect the following:
– power supply of 110…127 Vdc, reduces output current by 25%
– min. voltage allowed 100 Vdc, max 340 for single phase, 280…775 Vdc for single/
two-phase, 564… 775Vdc for three-phase (please see technical data)
– respect input polarity as indicated in the instructions.
figure 2
L
Note for power supplies with secondary input from a
transformer
AC
–
–
AC
+
+
GND
V
+V
N
INSULATION: this series of power supply units is not insulated.
TYPE OF USE: they are suitable for use in PELV (one pole of the Protective Extra Low
Voltage earthed) and SELV (Safety Extra Low Voltage, no pole earthed).
The transformer used must have double or reinforced isolation in accordance with CEI
14.6 / EN 60742.
In the case of use in PELV circuits, only earth one pole of the 24 Vdc of the power
supply unit.
In the case of use in SELV circuits, do not earth the input earth terminal.
Earthing one pole of the secondary of the transformer and the 24Vdc of the
power supply would damage the power supply.
AC
–
AC
+
0
-V
V
GND
–
AC
–
figure 3
24 Vdc
load
24 Vac / 24 Vdc not isolated
power supply
24 Vdc
load
230 Vac / 24 Vac Transformer
figure 4
230 Vac / 24 Vdc power supply
230 Vac / 24 Vac Transformer
figure 5
13
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Single-phase switching power supply - Cool Power series
Output voltage
Output current
Input voltage
Notes
10…15 Vdc
1.5…1 A
90…264 Vac / 100...320 Vdc
(1) (8) (9)
12…15 Vdc
6A
90…264 Vac / 100...345 Vdc
(1) (7) (8) (9)
Type
Cat. No.
Page
CSF30B
XCSF30B
22
CSF85B
XCSF85B
23
12…15 Vdc
16 A
120 Vac / 230 Vac
(2) (7) (8)
CSF240B
XCSF240B
25
24 Vdc
1.2 A
90…264 Vac / 100...320 Vdc
(1) (9)
CSF30C
XCSF30C
22
24 Vdc
3.5 A
90…264 Vac / 100...345 Vdc
(1) (7) (9)
CSF85C
XCSF85C
23
24 Vdc
3.5 A
90…264 Vac / 100...345 Vdc
(1) (6) (7) (9)
CSF85CP
XCSF85CP
23
24 Vdc
5A
90…264 Vac / 100...345 Vdc
(1) (7) (9)
CSF120C
XCSF120C
24
24 Vdc
5A
90…264 Vac / 100...345 Vdc
(1) (6) (7) (9)
CSF120CP
XCSF120CP
24
24 Vdc
10 A
120 Vac / 230 Vac
(2) (7)
CSF240C
XCSF240C
25
24 Vdc
10 A
120 Vac / 230 Vac
(2) (6) (7)
CSF240CP
XCSF240CP
25
24 Vdc
20 A
120 Vac / 230 Vac
(2) (6) (7)
CSF500C
XCSF500C
27
48 Vdc
2.5 A
90…264 Vac / 100...345 Vdc
(1) (6) (7)
CSF120DP
XCSF120DP
24
48 Vdc
5A
120 Vac / 230 Vac
(2) (6) (7)
CSF240DP
XCSF240DP
25
48 Vdc
10 A
120 Vac / 230 Vac
(2) (6) (7)
CSF500D
XCSF500D
27
72 Vdc
3.5 A
120 Vac / 230 Vac
(2) (6) (7) (8)
CSF240G
XCSF240G
26
72 Vdc
6.7 A
120 Vac / 230 Vac
(2) (6) (7) (8)
CSF500G
XCSF500G
28
Single-phase switching power supply - Easy Power series
Output voltage
Output current
Input voltage
Notes
Type
Cat. No.
Page
24 Vdc
3.5 A
90…264 Vac
(1)
CSL85C
XCSL85C
31
24 Vdc
5A
90…264 Vac
(1)
CSL120C
XCSL120C
32
24 Vdc
10 A
120 Vac / 230 Vac
(2)
CSL240C
XCSL240C
33
24 Vdc
20 A
230 Vac
-
CSL481C
XCSL481C
34
Single-phase switching power supply - Domotic Power series
Output voltage
Output current
Input voltage
Notes
Type
Cat. No.
Page
18
5…15 Vdc
3...1.5 A
90…264 Vac / 100...345 Vdc
(1) (8) (9)
CSD30E
XCSD30E
±12…±15
0.6 A
90…264 Vac / 100...345 Vdc
(1) (8) (9)
CSD30F
XCSD30F
18
12 Vdc
1.2 A
90…264 Vac / 100...315 Vdc
(1) (9)
CSD15B
XCSD15B
17
12…15 Vdc
3.5…3 A
90…264 Vac / 100...345 Vdc
(1) (8) (9)
CSD50B
XCSD50B
19
24 Vdc
0.6 A
90…264 Vac / 100...315 Vdc
(1) (9)
CSD15C
XCSD15C
17
24 Vdc
1.2 A
90…264 Vac / 100...345 Vdc
(1) (9)
CSD30C
XCSD30C
18
24 Vdc
3A
90…264 Vac / 100...345 Vdc
(1) (9)
CSD70C
XCSD70C
20
Single phase, 2-phase and 3-phase switching power supply - Universal Power series
Output voltage
Output current
Input voltage
Notes
Type
Cat. No.
Page
12…15 Vdc
8…7 A
1-2x 230-400-500 Vac
(1) (3) (7) (8) (9)
CSW121B
XCSW121B
36
12…15 Vdc
16…15 A
1-2-3x 230-400-500 Vac
(1) (3) (4) (7) (8) (9)
CSW241B
XCSW241B
37
24 Vdc
5A
1-2x 230-400-500 Vac
(1) (3) (7) (9)
CSW121C
XCSW121C
36
24 Vdc
10 A
1-2-3x 230-400-500 Vac
(1) (3) (4) (7) (9)
CSW241C
XCSW241C
37
24 Vdc
20 A
1-2-3x 230-400-500 Vac
(1) (3) (4) (7) (9)
CSW481C
XCSW481C
38
48 Vdc
2.5 A
1-2x 230-400-500 Vac
(1) (3) (6) (7) (9)
CSW121DP
XCSW121DP
36
48 Vdc
5A
1-2-3x 230-400-500 Vac
(1) (3) (4) (6) (7) (9)
CSW241DP
XCSW241DP
37
48 Vdc
10 A
1-2-3x 230-400-500 Vac
(1) (3) (4) (7) (9)
CSW481D
XCSW481D
38
72 Vdc
3.3 A
1-2-3x 230-400-500 Vac
(1) (3) (4) (6) (7) (8) (9)
CSW241G
XCSW241G
37
72 Vdc
6A
1-2-3x 230-400-500 Vac
(1) (3) (4) (7) (8) (9)
CSW481G
XCSW481G
38
14
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
3-phase switching power supply - Triple Power series
Output voltage
Output current
Input voltage
Notes
Type
Cat. No.
Page
24 Vdc
20 A
3x 400-500 Vac
(4) (7)
24 Vdc
20 A
3x 400-500 Vac
(4) (7)
CSG481C
XCSG481C
40
CSG500C
XCSG500C
41
24 Vdc
30 A
3x 400-500 Vac
(4) (7)
24 Vdc
40 A
3x 400-500 Vac
(4) (7)
CSG720C
XCSG720C
42
CSG960C
XCSG960C
43
24 Vdc
100 A
3x 400-500 Vac
48 Vdc
10 A
3x 400-500 Vac
(4) (6) (7) (8)
CSG2401C
XCSG2401C
44
(4) (6) (7)
CSG500D
XCSG500D
41
48 Vdc
15 A
3x 400-500 Vac
(4) (6) (7)
CSG720D
XCSG720D
42
48 Vdc
20 A
3x 400-500 Vac
(4) (6) (7)
48 Vdc
50 A
3x 400-500 Vac
(4) (6) (7) (8)
CSG960D
XCSG960D
43
CSG2401D
XCSG2401D
44
72 Vdc
6.7 A
3x 400-500 Vac
(4) (6) (7) (8)
CSG500G
XCSG500G
41
72 Vdc
13.3 A
3x 400-500 Vac
(4) (6) (7) (8)
CSG960G
XCSG960G
43
72 Vdc
33 A
3x 400-500 Vac
(4) (6) (7) (8)
CSG2401G
XCSG2401G
45
170 Vdc
14 A
3x 400-500 Vac
(4) (6) (7) (8)
CSG2401R
XCSG2401R
45
Power supply with IP65 protection degree
Output voltage
Output current
Input type
Input voltage
Notes
Type
Cat. No.
Page
24 Vdc
5A
single-phase
90…264 Vac / 100...345 Vdc
(1) (7) (9)
CSF565
XCSF565
29
Type
Cat. No.
Page
Power supply with input from transformer
Output voltage
Output current
Input type
Input voltage
Notes
1.2…24 Vdc
1.5 A
from transformer
9…26 Vac
(5) (8)
CL1R
XCL1R
51
1.2…24 Vdc
5A
from transformer
9…26 Vac
(5) (8)
CL5R
XCL5R
51
Filtered power supply with not stabilised output
Output voltage
Output current
Input type
Input voltage
Notes
Type
Cat. No.
Page
12…24 Vdc
1A
from transformer
9…20 Vac
(5)
AR1
XAR1
52
12…24 Vdc
6A
from transformer
9…20 Vac
(5)
AR6
XAR6
52
DC/DC isolated converter
Input voltage
Output voltage
Output current
Notes
Type
Cat. No.
Page
12 Vdc
24 Vdc
5A
(9)
CSA120BC
XCSA120BC
46
12 Vdc
48 Vdc
2.5 A
(9)
CSA120BD
XCSA120BD
46
24 Vdc
12…15 Vdc
7A
(8) (9)
CSA120CB
XCSA120CB
46
24 Vdc
24 Vdc
5A
(9)
CSA120CC
XCSA120CC
46
48 Vdc
12…15 Vdc
8A
(8) (9)
CSA120DB
XCSA120DB
47
48 Vdc
24 Vdc
5A
(9)
CSA120DC
XCSA120DC
47
110 Vdc
24 Vdc
10 A
(6) (7) (9)
CSA240FC
XCSA240FC
48
(All single phase wide range power supply can be feed at 110 Vdc)
(5) input from a secondary of a transformer
(6) redundant version
(8) with failure contact (power good)
(8) with adjustable output
(9) DC/DC converter
Note
(1) wide range single-phase input
(2) double range single-phase input
(3) two-phase input
(4) three-phase input
15
Modular switching power supply CSD series
DOMOTIC POWER
Single phase switching power supplies with output power up to 70W for civil and industrial
automation applications.
The housings have the standard dimensions for installation in DIN modular panels, and are optimized
for the deployment in the field of building automation. The high performance and compact size
make them an excellent solution for low-depth electrical panels.
The high efficiency and low dissipated power save energy and increase the life of the components.
Suggested uses
• Applications in industrial automation
• Applications in civil automation
• General applications in systems fit into small remote panels
Main features
• The 90…264 Vac and 110…370 Vdc input makes them suitable for use on all power supply lines.
• These power supplies are Insulation Class 2, thus they don’t require grounding, which reduces costs
and times during installation into remote panels, surveillance and monitoring systems.
• Their high efficiency reduces energy consumption and working temperature and allows their use in
small panels.
• Their backup power allows the supply of continuous current at least +50% above the rated value
ensuring safety and reliability.
• Dimensioned power supply and surge protection supplying breakaway starting currents 150%
above the rated value required by heavy loads.
• Thermal protection prevents faults caused by prolonged overload at high ambient temperatures.
• Their internal components’ high efficiency and excellent ventilation offer small dimensions and IP20
protection against accidental contacts in compliance with IEC529.
Short circuit and overload
Designed to provide load start up
current required by medium loads
Compact size
Ideal solution for electrical
panels with low profile
High Efficiency
Designed to save energy
and reduce working
temperature
Power boost
The output power
supplied reaches up to
130% of the rated value
90…264 Vac and 110…350 Vdc input wide range
Suitable in single phase voltage networks
16
Single-phase switching
power supply 120-230 Vac
output power 15 W
90
(3.55 in)
• Single-phase input 90…264 Vac and DC 100…315 Vdc
• Short circuit, overload, over temperature, input
overvoltage protections
• Isolation Class 2, no grounding needed
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
E203601
35
(1.23 in)
62
(2.44 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) Over 50°C (122°F) apply a derating: C version: -0.015 A/°C;
B version: -0.03 A/°C.
(3) Overload and short circuit current depends on the total line
resistance
VERSIONS
Output 24 Vdc 0.6 A
Output 24 Vdc 0.6 A redundant version
Output 12 Vdc 1.2 A
Output 48 Vdc 0.3 A
Cod. XCSD15C
CSD15C
Cod. XCSD15B
–
CSD15B
–
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…315 Vdc)
47...63 Hz
0.3 A / 0.16 A ± 10%
<5A
> 0.6
T 1 A replaceable
circuit breaker: 2 A - C characteristic - fuse: T 2 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc ± 1%
—
0.6 A @ 50°C (2)
1.08 A
(3)
—
< 1%
≤ 30 mVpp
>12 ms / >20 ms
12 Vdc ± 0.5 Vdc
—
1.2 A @ 50°C (2)
2.16 A
(3)
—
< 1%
≤ 30 mVpp
>12 ms / >20 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
–
–
possible
possible
possible with external ORing
possible with external ORing
diode
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>85% / >87%
2,5 W / 2,2 W
–20...+60°C, with derating over 50°C / over temperature protection (2)
3 kVac / 60 s SELV output
class 2 without PE connection
class 2 without PE connection
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>750’000 h acc. to SN 29500 / >250’000 h acc. to MIL Std. HDBK 217F
,, / 2
IP 20 IEC 529, EN60529
2.5 mm2 fixed screw type
UL94V-0 plastic material
130 g (5.12 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
17
Single-phase switching
power supply 120-230 Vac
output power 30 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature, input
overvoltage protections
• Isolation Class 2, no grounding needed
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
90
90
62
62
71
E203601
71
NOTES
AC
N
+U
+
+
AC
L
AC
+
0
–
VERSIONS
+
FILTER
L
N
+
+U
0
+
+
AC
PWM
Output 24 Vdc 1.2 A
Output 24 Vdc 1.2 A redundant version
Output 5…15 Vdc 3.3…1.5 A
Output ±12...±15 Vdc 0.6 A
(2.44 in)
(2.8 in)
BLOCK DIAGRAM
FILTER
The depth dimension includes the DIN rail clamp.
(2) Over 50°C (122°F) apply a derating: C and F versions:
-0.03 A/°C; E version: -0.08…-0.04 A/°C.
(3) Overload and short circuit current depends on the total line
resistance.
(4) Output current depends on the output voltage: 3.3A @ 5Vdc,
2A @ 9Vdc, 2.2A @ 12Vdc, 1.5A @ 15Vdc.
(3.55 in)
–U
–
PWM
Cod. XCSD30C
CSD30C
Cod. XCSD30E
Cod. XCSD30F
–
CSD30E
CSD30F
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…345 Vdc)
47...63 Hz
0.45 A / 0.25 A ± 10%
< 13 A
> 0.6
T 2 A replaceable
circuit breaker: 3 A - C characteristic - fuse: T 3.15 A
0.55 A / 0.28 A ± 10%
< 13 A
0.4 A / 0.2 A ± 10%
< 13 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc ± 1%
—
1.2 A @ 50°C (2)
1.6
(3)
—
< 1%
≤ 50 mVpp
>30 ms / >60 ms
5…15 Vdc
±12...±15 Vdc
5…15 Vdc
±12...±15 Vdc
3.3…1.5 A @ 50°C (2)(4)
2x0.6 A @ 50°C (2)
4A
(3)
>2x0.8 A
(3)
—
—
< 1%
< 1%
≤ 50 mVpp
≤ 50 mVpp
>50 ms / >100 ms
>50 ms / >100 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
–
–
–
–
possible
possible
possible
possible with external ORing
possible with external ORing
possible with external ORing
diode
diode
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>85% / >87%
5,1 W / 4,3 W
>87% / >89%
>87% / >89%
4,0 W / 3,4 W
1,6 W / 1,3 W
–20...+60°C, with derating over 50°C / over temperature protection (2)
3 kVac / 60 s SELV output
class 2 without PE connection
class 2 without PE connection
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>750'000 h acc. to SN 29500 / >250'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
200 g (7.06 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
18
Single-phase switching
power supply 120-230 Vac
output power 50 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature, input
overvoltage protections
• Isolation Class 2, no grounding needed
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
90
(3.55 in)
E203601
62
(2.44 in)
71
(2.8 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%
(3) O v e r 5 0 ° C ( 1 2 2 ° F ) a p p l y a d e r a t i n g :
C version: -0.06 A/°C; B version: -0.085 A/°C.
(4) Overload and short circuit current depends on the total line
resistance.
VERSIONS
Output 24 Vdc 2.2 A
Output 24 Vdc 2.2 A redundant version
Output 12…15 Vdc 3.5...3 A
Output 48 Vdc 1.1 A
Cod. XCSD50B
–
CSD50B
–
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
47...63 Hz
0.9 A / 0.5 A ± 10%
< 15 A
> 0.6
T 2 A replaceable
circuit breaker: 3 A - C characteristic - fuse: T 3.15 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
12…15 Vdc
12…15 Vdc
3.5…3 A @ 50°C (3)
4.37…3.75 A
(4)
—
< 1%
≤ 50 mVpp
>20 ms / >40 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
–
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>85% / >88%
7,9 W / 6,1 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output
class 2 without PE connection
class 2 without PE connection
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>750'000 h acc. to SN 29500 / >250'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
200 g (7.06 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
19
Single-phase switching
power supply 120-230 Vac
output power 70 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature, input
overvoltage protections
• Isolation Class 2, no grounding needed
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
88
(3.46 in)
E203601
NOTES
63
(2.48 in)
70
(2.76 in)
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%.
(3) Over 50°C (122°F) apply a derating: C version: -0.15 A/°C.
(4) Overload and short circuit current depends on the total line
resistance.
VERSIONS
Output 24 Vdc 3 A
Output 24 Vdc 3 A redundant version
Output 12…15 Vdc 5…4 A
Output 48 Vdc 1.5 A
Cod. XCSD70C
CSD70C
–
–
–
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…370 Vdc) (2)
47...63 Hz
1.25 A / 0.8 A ± 10%
< 15 A
> 0.6
T 2 A not replaceable
circuit breaker: 4 A C characteristic - fuse: T 3.15 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
24...27.5 Vdc
3 A @ 55°C (3)
4A
(4)
—
< 1%
≤ 60 mVpp
>15 ms / >30 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
–
possible
possible with external ORing
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>87% / >89%
10,8 W / 8,9 W
–20...+60°C, with derating over 55°C (3)
3 kVac / 60 s SELV output
class 2 without PE connection
class 2 without PE connection
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>750'000 h acc. to SN 29500 / >250'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
250 g (8.82 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
20
COOL POWER
DIN-rail single phase switching power supplies, specifically designed for applications in industrial
automation panels and process control panels. They can deliver +60% to +80% of the nominal current for a
sustained period keeping the output voltage constant; the alarm contact is controlled by a voltage threshold,
and it switches when the voltage drops under 90% of the rated output value.
Thanks to these features and to the numerous international certifications, this series of power
supplies allows engineers to meet all the requirements of the new EN 60204-1 Machinery Directive,
to enable the protection devices connected to the output to trigger quickly, safely and above all selectively,
thus ensuring continuity of service to the other parts of the system.
Suggested uses
• Applications in industrial automation requiring high levels of efficiency and reliability
• Applications requiring selectivity of surge protection devices on DC lines.
• Application in machinery automation requiring high levels of reliability in terms of control and safety voltage
• Applications in process control
• Heavy duty uses
• Applications in civil automation
Main features
• The 90…264 Vac and 110…370 Vdc input makes them suitable for use on all power supply lines.
• Threshold alarm contact warning when the voltage drops 90% below the rated value.
• Versions with integrated Oring diode for redundant parallel connections, avoiding the use of external devices
and reducing dimensions and installation costs.
• Their high efficiency reduces energy consumption and components’ operating temperature allowing their
use in small panels and under severe ambient conditions.
• Their backup power allows the supply of current and voltage at least +60-80% above the rated value for a
few minutes ensuring safety and reliability.
• The output voltage may be adjusted and the output is protected against the input of surges coming from the
DC line and caused by inductive loads.
• The output is equipped with double electronic protection devices preventing dangerous voltages which may
damage powered components in the event of internal faults.
• Thermal protection prevents faults in the event of prolonged overloads at high ambient temperatures.
• Their design ensures excellent ventilation to internal components, small dimensions and IP20 protection
against accidental contacts in compliance with IEC529.
• Thanks to their high efficiency and excellent ventilation, they are the smallest devices available on the market.
Extremely compact dimensions
They are among the smallest on the market,
optimising the use of space in the panel
without compromising performance
Short circuit and overload
Designed to provide load start
up current required
by heavy loads
Power boost
The output power
reaches 120% of
the nominal value for
several minutes, up
to 160% during an
overload, and up to
300% in the event of a
short-circuit, to enable
the protection devices
connected to the output
to trigger quickly, safely
and selectively, without
the use of additional
modules
High Efficiency
Designed to save energy
and reduce working
temperature
Integrated smart alarm contact
90…264 Vac and 110…350 Vdc input wide range
Suitable in all single phase supply voltage networks
Activated when output voltage decreases
below 90% of rated value
21
Special power supplies for engines in DC,
Brushless, and relative drives
New 48Vdc and 72-85Vdc models have been
introduced, designed to reliably power engines
in DC. They:
• Supply peak power equal to even 4-5 times
the nominal current, which is required by the
engine during the peak phase
• Have an output stage protected from
overvoltage generated by the engines and
drives during braking, which could otherwise
cause malfunctions or cause the power supply
to lose control over output voltage stability
• Provide output voltage at 48Vdc, and 72-85Vdc.
By increasing the voltage of the engine power
supply, the same power can be obtained at
lower current, with notable advantages for
performance, engine construction, cables, and
drives.
Single-phase switching
power supply 120-230 Vac
output power 30 W
82
(3.23 in)
• Single-phase input 90…264 Vac and DC 100…320 Vdc
• Short circuit, overload, over temperature protection
• Isolation Class 2, no grounding needed
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
23
(0.91 in)
E212719
E203601
NOTES
BLOCK DIAGRAM
AC
N
+U
+
+
AC
L
+
0
–
AC
+
FILTER
L
FILTER
The depth dimension includes the DIN rail clamp.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%
(3) Over 50°C (122°F) apply a derating: C version: -0.03 A/°C;
B version: -0.038 A/°C; F version: -0.013 A/°C
(4) Overload and short circuit current depends on the total line
resistance.
N
VERSIONS
Cod. XCSF30C
CSF30C (1)
+U
+
0
+
+
AC
–U
–
PWM
Output 24 Vdc 1.2 A
Output 10…15 Vdc 1.5 A
Output ±12...±15 Vdc 0.5 A
99
(3.9 in)
PWM
Cod. XCSF30B
Cod. XCSF30F
CSF30B (1)
CSF30F
(1)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…320 Vdc) (2)
47...63 Hz
0.35 A / 0.2 A ± 10%
< 25 A
> 0.60
T 1,25 A not replaceable
circuit breaker: 2 A - C characteristic - fuse: T 2 A
0.55 A / 0.3 A ± 10%
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc ± 1%
—
1.2 A @ 50°C (3)
1.4 A
(4)
—
12 – 15 Vdc
10…15 Vdc
1.5…1 A @ 50°C (3)
1.7…1.2 A
(4)
—
±12 ±15 Vdc
±12…±15 Vdc
0.5 A @ 50°C (3)
0.8…0.6 A
(4)
—
< 1%
≤ 50 mVpp
>10 ms / >30 ms
hiccup at the overload limit with auto reset
“DC OK” green LED
—
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >87%
4.7 W / 4.3 W
–20...+60°C, with derating over 50°C (3)
3 kVac / 60 s SELV output
class 2 without PE connection
class 2 without PE connection
EN50178, EN61558, EN60950, IEC950, UL508, UL60950
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>750'000 h acc. to SN 29500 / >250'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
140 g (4.94 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
22
Single-phase switching
power supply 120-230 Vac
output power 85 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• Failure contact for Uout -10%
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
115
(4.53 in)
128
(5.04 in)
(5)
E212719
E203601
39
(1.54 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%
(3) Over 45°C (113°F) apply derating: CSF3-CSF3P: -0.06 A/°C
for version C, CP and CPH; -0.10 A/°C for version B
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Available ATEX version (II3G Ex nA nC IIC T4 Gc X), for order
adds "-EX" to the code, example XCSF85C-EX.
VERSIONS
Output 24 Vdc 3.5 A
Output 24 Vdc 3.5 A redundant version
Output 12…15 Vdc 6 A
Output 48 Vdc 1.8 A
Cod. XCSF85C
CSF85C
Cod. XCSF85CP
Cod. XCSF85B
CSF85CP
CSF85B
–
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
47...63 Hz
1.6 A / 0.9 A ± 10%
< 20 A
> 0.65
T 2 A replaceable
circuit breaker: 4 A - C characteristic - fuse: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
12…15 Vdc
23...27.5 Vdc
12…15 Vdc
3.5 A @ 50°C
(3)
6 A @ 50°C
(3)
6 A for >30 s
9 A for >30 s
with Uout >90% Un (4)
with Uout >90% Un (4)
10 A for 50 ms
(4)
10 A for 50 ms
(4)
< 1%
< 1%
≤ 70 mVpp
≤ 30 mVpp
>20 ms / >70 ms
>15 ms / >60 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
21.6 Vdc
10.8 Vdc
possible
possible
possible with external ORing
factory provided with internal
possible with external ORing diode
diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >90%
>83% / >87%
14 W / 10 W
17 W / 13 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508, UL60950
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
400 g (14.12 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
23
Single-phase switching
power supply 120-230 Vac
output power 120 W
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature, input and
output overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• Failure contact for Uout -10%
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
115
(4.53 in)
128
(5.04 in)
(5)
E212719
E203601
39
(1.54 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN clamp.
(2) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%
(3) Over 45°C (113°F) apply a derating-0.08 A/°C for version C, CP and
CPH; -0.12 A/°C for version B; -0.05 A/°C for version DP;
(4) For this peak current, the output voltage does not drop more than
10% of the nominal value, but the current value, provided by the
power supply also depends on the total line resistance.
(5) Available ATEX version (II3G Ex nA nC IIC T4 Gc X), for order adds
"-EX" to the code, example XCSF120C-EX.
(6) article available till seel-out
VERSIONS
Output 24 Vdc 5 A
Output 24 Vdc 5 A redundant version
Output 12…15 Vdc 7 A
Output 48 Vdc 2.5 A
Special version
motors
Versione
specialeforforDCmotori
DC
Cod. XCSF120C
CSF120C
Cod. XCSF120CP
Cod. XCSF120B
Cod. XCSF120DP
CSF120CP
CSF120B (6)
CSF120DP
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…345 Vdc) (2)
47...63 Hz
1.9 A / 1.1 A ± 10%
< 20 A
> 0.65
T 3.15 A replaceable
circuit breaker: 4 A - C characteristic - fuse: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
12…15 Vdc
48 Vdc
23...27.5 Vdc
12…15 Vdc
45…55 Vdc
5 A @ 45°C
(3)
7 A @ 45°C
(3)
2.5 A @ 45°C
(3)
8 A for >30 s
8 A for >30 s
8 A for >30 s
with 90% Un (4)
with 90% Un (4)
with 90% Un (4)
15 A for 50 ms
(4)
15 A for 50 ms (4)
7.5 A for 50 ms (4)
< 1%
< 1%
< 1%
≤ 30 mVpp
≤ 40 mVpp
≤ 30 mVpp
>17 ms / >72 ms
>24 ms / >80 ms
>16 ms / >81 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
<21.6 Vdc
<10.8 Vdc
<43.2 Vdc
possible
possible
possible
possible with external ORing
factory provided with internal
possible with external ORing
factory provided with internal
diode
ORing diode
diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >90%
>85% / >89%
>86% / >90%
19 W / 13 W
21 W / 15 W
20 W / 13 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508, UL60950
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
400 g (14.12 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
24
Single-phase switching
power supply 120-230 Vac
output power 240 W
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• Failure contact for Uout -10%
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
140
(5.51 in)
135
(5.32 in)
(5)
E212719
E203601
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(2) Double input selectable with external jumper, DC supply allow
only between 300 and 345 Vdc
(3) Over 45°C (113°F) apply a derating: -0.17 A/°C for version C, CP
and CPH; -0.27 A/°C for version B; -0.08 A/°C for version DP;
(4) For this peak current, the output voltage does not drop more
than 10% of the nominal value, but the current value, provided
by the power supply also depends on the total line resistance.
(5) Available ATEX version (II3G Ex nA nC IIC T4 Gc X), for order
adds "-EX" to the code, example XCSF240C-EX.
VERSIONS
Output 24 Vdc 10 A
Output 24 Vdc 10 A redundant version
Output 12…15 Vdc 16 A
Output 48 Vdc 5 A redundant version
63.5
(2.5 in)
ORing diode only on "P" version
L
AC
N
+
+
+
+
FILTER
PE
+
AC
+
–
–
–
PWM
120 Vac selection terminals
Special version for DC motors
Cod. XCSF240C
CSF240C
Cod. XCSF240CP
Cod. XCSF240B
XCSF240DP
CSF240CP
CSF240B
CSF240DP
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120 - 230 Vac (range 90…132 Vac / 185…264 Vac / 300...345 Vdc)
47...63 Hz
3.5 A / 1.8 A ± 10%
< 35 A
> 0.6
T 6.3 A replaceable
circuit breaker: 10 A - C characteristic - fuse: T 10 A
(2)
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
12…15 Vdc
48 Vdc
23...27.5 Vdc
12…15 Vdc
45…55 Vdc
10 A @ 45°C
(3)
16 A @ 45°C
(3)
5 A @ 45°C
(3)
15 A for >30 s
24 A for >30 s
7.5 A for >30 s
with Uout >90% Un (4)
with Uout >90% Un (4)
with Uout >90% Un (4)
>25 A for 400 ms
(4)
>25 A for 400 ms (4)
>25 A for 400 ms (4)
< 1%
< 1%
< 1%
≤ 50 mVpp
≤ 50 mVpp
≤ 50 mVpp
>30 ms / >60 ms
>30 ms / >60 ms
>30 ms / >60 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
21.6 Vdc
10.8 Vdc
43.2 Vdc
possible
possible
possible
possible with external ORing
factory provided with internal
possible with external ORing
factory provided with internal
diode
ORing diode
diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>88% / >90%
>85% / >85%
>89% / >89%
32 W / 27 W
42 W / 42 W
28 W / 28 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508, UL60950
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
920 g (32.48 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
25
Single-phase switching
power supply 120-230 Vac
output power 240 W
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• Failure contact for Uout -10%
• Compact dimensions
• Suitable for applications in PELV circuits
140
(5.51 in)
135
(5.32 in)
E203601
63.5
(2.5 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(2) Double input selectable with external jumper, DC supply allow
only between 300 and 345 Vdc
(3) Over 45°C (113°F) apply a derating: -0.17 A/°C for version C, CP
and CPH; -0.27 A/°C for version B; -0.08 A/°C for version DP;
(4) For this peak current, the output voltage does not drop more
than 10% of the nominal value, but the current value, provided
by the power supply also depends on the total line resistance.
(5) Version CSF240G is not suitable for SELV applications
L
N
AC
+
+
+
+
FILTER
PE
+
AC
+
–
–
–
PWM
120 Vac selection terminals
Special version for DC motors
VERSIONS
Output 72 Vdc 3.5 A redundant version
Cod. XCSF240G
CSF240G
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120 - 230 Vac (range 90…132 Vac / 185…264 Vac / 300...345 Vdc)
47...63 Hz
3.5 A / 1.8 A ± 10%
< 35 A
> 0.6
T 6.3 A replaceable
circuit breaker: 10 A - C characteristic - fuse: T 10 A
(2)
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
72 Vdc
72…85 Vdc
3.5 A @ 50°C (3)
>13.8A for >30 s with Uout
>90% Un (4)
>25 A for 400 ms (4)
< 1%
≤ 50 mVpp
>30 ms / >60 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
64.8 Vdc
possible
factory provided with internal
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>89.5% / >89.5%
28 W / 28 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s not SELV output (5)
1.5 kVac / 60 s
0.5 kVac / 60 s
IEC950, EN60950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
920 g (32.48 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
26
Single-phase switching
power supply 120-230 Vac
output power 500 W
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature, input and
output overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• Compact dimensions
• Suitable for applications in SELV and PELV circuits
• Failure contact for Uout -10%
127
(5 in)
E212719
E203601
80
(3.15 in)
NOTES
139
(5.48 in)
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) Double input selectable with external jumper.
(3) Over 45°C (113°F) apply a derating: C version: -0.34 A/°C
for version C; -0.17 A/°C for version D;
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
L
AC
N
+
+
+
+
FILTER
PE
+
AC
+
–
–
–
PWM
120 Vac selection terminals
Special version for DC motors
VERSIONS
Output 24 Vdc 20 A
Output 24 Vdc 20 A redundant version
Output 12…15 Vdc 40 A
Output 48 Vdc 10 A redundant version
Cod. XCSF500C
Cod. XCSF500D
–
CSF500C
–
CSF500D
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…132 Vac / 185…264 Vac) (2)
47...63 Hz
4.1 A / 2 A ± 10%
< 25 A with electronic limiter
> 0.75 with PFC
—
circuit breaker: 16 A C characteristic - fuse: T 15 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
48 Vdc
24...28 Vdc
45…55 Vdc
20 A @ 45°C (3)
10 A @ 45°C (3)
30 A for >5 s
15 A for >5 s
with Uout >90% Un (4)
with Uout >90% Un (4)
>50 A for 5 s (4)
>50 A for 5 s (4)
< 0.5%
< 0.5%
≤ 50 mVpp
≤ 50 mVpp
>12 ms / >20 ms
>12 ms / >20 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
21.6 Vdc
43.2 Vdc
possible
possible
factory provided with internal
factory provided with internal ORing diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>92% / >92%
>92% / >92%
42 W / 42 W
42 W / 42 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
4 and 6 mm² fixed screw type
aluminium
1,3 kg (45.89 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
27
Single-phase switching
power supply 120-230 Vac
output power 500 W
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature, input and
output overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• Compact dimensions
• Suitable for applications in PELV circuits
127
(5 in)
E203601
80
(3.15 in)
NOTES
139
(5.48 in)
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) Double input selectable with external jumper.
(3) Over 45°C (113°F) apply a derating: C version: -0.34 A/°C
for version C; -0.17 A/°C for version D;
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version CSF240G is not suitable for SELV applications
L
N
AC
+
+
+
+
FILTER
PE
+
AC
+
–
–
–
PWM
120 Vac selection terminals
Special version for DC motors
VERSIONS
Sortie 72 Vdc 6.7 A redundant version
Cod. XCSF500G
CSF500G
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (échelle 90…132 Vac / 185…264 Vac) (2)
47...63 Hz
8.4 A / 4.4 A ± 10%
< 35 A
> 0.67
—
circuit breaker: 16 A C characteristic - fuse: T 15 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
72 Vdc
72…85 Vdc
6.7 A @ 50°C (3)
>10A for >5 s with
Uout >90% Un (4)
>20 A for 400 ms (4)
< 1%
≤ 100 mVpp
>30 ms / >35ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
<64.8 Vd
possible
factory provided with internal
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>92% / >92%
42 W / 42 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
2 kVac / 60 s
0.7 kVac / 60 s
IEC950, EN60950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
IP 20 IEC 529, EN60529
4 and 6 mm² fixed screw type
aluminium
1,3 kg (45.89 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
28
Single-phase switching
power supply 120-230 Vac
IP65 protection degree
• Single-phase input 90…264 Vac and DC 100…345 Vdc
• Short circuit, overload, over temperature, input and
output overvoltage protections
• Suitable to be mounted directly on the machinery frame,
don't require any protective enclosure
• IP65 pluggable screw connectors
• Suitable for applications in SELV and PELV circuits
120
(4.72 in)
190
(7,48 in)
E203601
80
(3.15 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%
(2) Overload and short circuit current depends on the total line
resistance.
(3) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Output 24 Vdc 5 A
Cod. XCSF565
CSF5-65 (3)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…345 Vdc) (1)
47...63 Hz
1.8 A / 1 A ± 10%
< 20 A
> 0.7
T 3.15 A replaceable
circuit breaker: 4 A - C characteristic - fuse: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23...27.5 Vdc
5 A @ 60°C
8 A (2)
—
< 1%
≤ 50 mVpp
>10 ms / >20 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact
—
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >90%
18,6 W / 12,6 W
–20...+60°C / over temperature protection
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² IP65 pluggable screw connectors
aluminium
1.9 kg (67.02 oz)
vertical on rail or panel mounting by means of screws
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
29
Switching power supply CSL series
EASY POWER
Single phase DIN rail power supplies for general applications in automation and installation.
With particulary high quality / price ratio, these products are ideal and convenient for applications
where loads do not require high peak currents. They can deliver over +50% of nominal current for a
sustained period, keeping the output voltage stable and ensuring continuity of supply to the system. With
these features, this range of power supplies enables designers to meet the requirements of
the Machinery Directive, EN 60204-1, allowing the protection devices connected to the output to
trigger quickly, safely and selectively, thus ensuring continuity of service to the other parts of the system.
Suggested uses
• Applications in civil automation
• General applications in the installation of systems
Main features
• Equipped with 120 - 230 Vac input, they are suitable for use in all single-phase networks.
• Their high efficiency reduces energy consumption and components’ operating temperature allowing
their use in small panels and under severe ambient conditions.
• Backup power +50% above the rated voltage ensuring safety and reliability.
• The output voltage may be adjusted and is protected against the input of surges caused by inductive
loads on the DC line and is equipped with double electronic protection devices preventing damages
to powered equipment in the event of internal faults.
• Short-circuit, overload and thermal protection devices prevent faults in the event of prolonged
overloads at high ambient temperatures.
• Their design ensures excellent ventilation to internal components, very small dimensions and IP20
protection against accidental contacts in compliance with IEC529.
• Compared to other products having similar power and costs, they offer higher performances,
functions and reliability.
Short circuit, overload and thermal protections
Avoids failures caused by overload
at high ambient temperatures
Adjustable output voltage
Protected against the input of surges
coming from the DC line and caused
by inductive loads
Power boost
The output power
reaches 120% of
the nominal value for
several minutes, up
to 150% during an
overload, and up to
300% in the event
of a short-circuit, to
enable the protection
devices connected to
the output to trigger
quickly, safely and
selectively, without
the use of additional
modulesi
Extremely
compact
dimensions
They are among the
smallest on the
market, optimising
the use of space in
the panel without
compromising
performance
High Performance
Reduces energy consumption and reduces the working temperature of the
components and allows use in small panel and in heavy environmental
conditions
30
Single-phase switching
power supply 120-230 Vac
output power 85 W
115
(4.53 in)
• Single-phase input 90…264 Vac
• Short circuit, overload, over temperature, input and
output overvoltage protections
• Suitable in civil automation and general applications in
the installation of systems
• Suitable for applications in SELV and PELV circuits
128
(5.04 in)
39
(1.54 in)
E203601
NOTES
L
PE
N
AC
+
AC
–
FILTER
The depth dimension includes the terminal blocks and the DIN
clamp.
(3) Over 45°C (113°F) apply a derating of -0.06 A/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
BLOCK DIAGRAM
+
+
+
+
–
–
PWM
VERSIONS
Output 24 Vdc 5 A
Output 24 Vdc 5
Cod. XCSL85C
CSL85C
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac)
47...63 Hz
1.6A / 0.9 A ± 10%
< 20 A
> 0.65
T 2 A replaceable
circuit breaker: 4 A - C characteristic - fuse: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23...27.5 Vdc
3.5 A @ 45°C (3)
5,5 A for >30 s with Uout >90% Un (4)
9 A for 50 ms
< 1%
70 mVpp
>20 ms / >70 ms
hiccup at the overload limit with auto reset / over temperature
protection
“DC OK” green LED
—
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >90%
14 W / 10 W
-20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>400'000 h acc. to SN 29500 / >100'000 h acc. to MIL Std.
HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
400 g (14.10 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
31
Single-phase switching
power supply 120-230 Vac
output power 120 W
• Single-phase input 90…264 Vac
• Short circuit, overload, over temperature, input and
output overvoltage protections
• Suitable in civil automation and general applications in
the installation of systems
• Suitable for applications in SELV and PELV circuits
115
(4.53 in)
128
(5.04 in)
39
E203601
(1.54 in)
NOTES
L
PE
N
AC
+
+
+
FILTER
The depth dimension includes the terminal blocks and the DIN
clamp.
(3) Over 45°C (113°F) apply a derating of -0.08 A/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
BLOCK DIAGRAM
+
AC
+
–
–
–
PWM
VERSIONS
Output 24 Vdc 5 A
Output 24 Vdc 5 A
Cod. XCSL120C
CSL120C
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac)
47...63 Hz
1.9 A / 1.1 A ± 10%
< 20 A
> 0.65
T 3.15 A replaceable
circuit breaker: 4 A - C characteristic - fuse: T 4 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23...27.5 Vdc
5 A @ 45°C (3)
8 A for >30 s with Uout > 90% Un (4)
13 A for 50 ms (4)
< 1%
30 mVpp
>17 ms / >72 ms
hiccup at the overload limit with auto reset / over temperature
protection
“DC OK” green LED
—
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >90%
19 W / 13 W
-20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>400'000 h acc. to SN 29500 / >100'000 h acc. to MIL Std.
HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
400 g (14.10 oz)
vertical on rail, allow 10 mm spacing between adjacent
components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
32
Single-phase switching
power supply 120-230 Vac
output power 240 W
• Single-phase input 120 and 230 Vac
• Short circuit, overload, over temperature, input and
output overvoltage protections
• Suitable in civil automation and general applications in
the installation of systems
• Suitable for applications in SELV and PELV circuits
140
(5.51 in)
135
(5.32 in)
E203601
(2.5 in) 63.5
NOTES
L
PE
N
AC
+
+
+
+
FILTER
The depth dimension includes the terminal blocks and the DIN
clamp.
(2) Double input selectable with external jumper.
(3) Over 45°C (113°F) apply a derating of -0.17 A/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version available after September 2011
BLOCK DIAGRAM
+
+
AC
–
–
–
PWM
120 Vac selection terminals
VERSIONS
Output 24 Vdc 10 A
Cod. XCSL240C
CSL240C (5)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…132 Vac / 185…264 Vac) (2)
47...63 Hz
3.5A / 1.8 A ± 10%
< 35 A
> 0.6 / >0.85
T 6.3 A replaceable
circuit breaker: 10 A - C characteristic - fuse: T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23...27.5 Vdc
10 A @ 45°C (3)
15 A for >30 s with Uout > 90% Un (4)
>25 A for 400 ms
< 1%
50 mVpp
>30 ms / >60 ms
hiccup at the overload limit with auto reset / over temperature
protection
“DC OK” green LED
—
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>88% / >90%
32 W / 27 W
-20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3,
EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>400'000 h acc. to SN 29500 / >100'000 h acc. to MIL Std.
HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
920 g (32.48 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
33
output power 480 W
Single-phase switching
power supply 230 Vac
• Single-phase input 230 Vac
• Short circuit, overload, over temperature, input and
output overvoltage protections
• Suitable in civil automation and general applications in
the installation of systems
• Suitable for applications in SELV and PELV circuits
140
(5.52 in)
137
(5.40 in)
E203601
NOTES
73
(2.88 in)
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(3) Over 45°C (113°F) apply a derating of about 16 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
VERSIONS
Output 24 Vdc 20 A
Cod. XCSL481C
CSL481C (5)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
230 Vac (range 187…264 Vac) (2)
47...63 Hz
–/2A
<20 A
> 0,95
circuit breaker: 6 A - C characteristic - fuse: T 6,3 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23...27.5 Vdc
20 A @ 45°C (3)
28 A (4)
50 A for 0,3 s
< 1%
≤ 100 mVpp
– / >20 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
21,6 Vdc
possible
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
– / >92%
– / 42 W
-20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>400'000 h acc. to SN 29500 / >100'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
1 kg (35.27 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
34
UNIVERSAL POWER
DIN rail switching power supplies with universal input 185 ... 550 Vac single phase, 2-phase and
3-phase applications in industrial automation and process control. The input circuit technology makes them
immune to surges caused by failures in the 3-phase networks with neutral wire, increasing application reliability.
Compared to single-phase power supplies, this series has a higher reliability in industrial environments.
The input circuit uses components with an operating voltage of 900 V, more resistant to voltage peaks present
in industrial networks, than the components used in single phase power supplies. The capability to operate from
185 to 550 Vac allows for installations in both single-phase 230V and 3-phase 400V networks.
Suggested uses
• In single or 3-phase systems requiring great flexibility
• Applications in industrial automation and process control
• Heavy duty uses
• Applications in civil automation
Main features
• The wide-range input 185…550 Vac may be supplied single-phase 230…240 Vac, 2-phase 208 Vac and
2-3-phase 400…500 Vac ensuring excellent adaptability to AC networks and enabling to get rid of the
isolating transformer.
• The 2-phase and 3-phase input enables to reduce dimensions, wiring, installation costs and space inside
the panel.
• They enable to get rid of the transformer for adapting to power voltages.
• Versions with DC OK alarm contact.
• Their high efficiency reduces energy consumption and components’ operating temperature allowing their
use in small panels and under severe ambient conditions.
• Great backup power allowing to supply at least + 50% above the rated voltage for 5 seconds ensuring safety
and reliability.
• The output voltage may be adjusted and is protected against the input of surges on the DC line and is
equipped with double electronic protection devices disconnecting output in the event of internal faults.
• Dimensioned short-circuit and overload protection supplying breakaway starting currents 150% above the
rated value required by heavy loads; thermal protection prevents failures in the event of prolonged overloads
at high ambient temperatures.
• Their design ensures excellent ventilation to internal components, very small dimensions and IP20
protection against accidental contacts in compliance with IEC529.
• Thanks to their high efficiency and excellent ventilation, they are the smallest devices available on the market.
Greater reliability
Compared to single-phase power supplies, this
Series is more reliable in industrial applications.
The input stage uses components with 900 V
operating voltage, which are more resistant to
voltage peaks in industrial power lines compared
to components used in single-phase supplies,
whose operating voltage is 550V in high-quality
power supplies, but often 400...450 V in lowcost products. Being able to work from 185
to 550 Vac, these power supplies are immune
to power failures; at 230 Vac input (L1-N),
when another device connected to L2-N goes
short, the neutral rises up to approx. 400 Vac
and the input is supplied phase/phase until the
protection is activated, which takes place - at
best -in 300 ms; this is one of the most common
causes of damages to 230-Vac single-phase
power supplies in industrial applications. Another
example of faults in 230-Vac single-phase
devices powered between phase-neutral is due
to the disconnection or accidental interruption
of the panel’s neutral from the system’s neutral:
failing to return to the neutral point, the neutral
rises up to phase voltage applying approx. 400
Vac to single-phase loads, inevitably damaging
the system.
185…550 Vac wide range input
Connectable in 230 or 240V single-phase lines, in
208 2-phase lines, 400 or 500 V 2-3-phase lines
for the maximum adaptability to the AC lines, by
removing the isolation transformer
Power boost
The output power reaches 120%
of the nominal value for several
minutes, up to 150% during an
overload, and up to 250% in the
event of a short-circuit, to enable
the protection devices connected
to the output to trigger quickly,
safely and selectively,
without the use of additional
Typical application with 3-phase network and neutral.
The latter is used to obtain a 230-Vac voltage in order
to supply power to loads (in the example, a simple bulb)
and power supplies.
2-phase input
Saves space, wiring,
installation costs
High Performance
Reduces energy
consumption and the
operating temperature of the
components
and allows installation
in small panels
Increased reliability in industrial environments
The input circuit uses components with a voltage of 900 V, more
resistant to voltage peaks typical in industrial networks
35
A simple short-circuit on the load causes a rise in the
neutral’s potential, all the devices connected to it will
be powered between two phases, i.e. with a value of
approx. 340...400 Vac instead of 230 Vac.
1 or 2-phase switching power
supply 230-400-500 Vac output
power 120 W
115
(4.53 in)
• Single-phase and 2-phase input 185...550 Vac
• High reliability and immunity against over voltage due to failures on
AC line
• Short circuit, overload, over temperature, input and output overvoltage
protections
• High outrush current to guarantee downstream overcurrent protections
selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
E203601
VERSIONS
(1.53 in)
BLOCK DIAGRAM
ORing diode only on "P" version
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) 550 Vdc max for UL508
(3) Over 50°C (122°F) apply a derating of about 3 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
Output 24 Vdc 5 A
Output 12…15 Vdc 7 A
Output 48 Vdc 2.5 A redundant version
Output 72 Vdc 1.5 A redundant version
39
NOTES
130
(5.12 in)
L1
(N)
L2
(L)
+
+
+
FILTER
AC
+
AC
+
–
–
–
PE
PWM
Cod. XCSW121C
CSW121C
Cod. XCSW121B
Cod. XCSW121DP
CSW121B
CSW121DP (1)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 230 / 400 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
1-2x 230-400-500 Vac (range 187…550 Vac / 270…725 Vdc)
47...63 Hz
1.1 A / 0.55 A
< 20 A
> 0.65
–
circuit breaker: 2x 6 A C characteristic - fuse: 2x T 4 A
(2)
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 230 / 400 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
24...27.5 Vdc
5 A (3)
7.5 A for >30 s
with Uout >90% Un
14 A for 0.4 s (4)
< 1%
≤ 100 mVpp
>20 ms / >80 ms
12…15 Vdc
48 Vdc
12…15 Vdc
45...55 Vdc
8 A @ 12 Vdc / 7 A @ 15 Vdc
2.5 A (3)
10 A for >30 s
3,75 A for >30 s
with Uout >90% Un
with Uout >90% Un (4)
20 A for 0.4 s (4)
14 A for 0.5 s (4)
< 1%
< 1%
≤ 100 mVpp
≤ 100 mVpp
>20 ms / >80 ms
>20 ms / >80 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
21.6 Vdc
10.8 Vdc
68 Vdc
possible
possible
possibile
possible with external ORing
possible with external ORing
prepared with diode
diode
diode
internal ORing
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac)
Dissipated power (Uin 230 / 400 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >88%
20 W / 16 W
>84% / >86%
>86% / >86%
20 W / 17 W
20 W / 20 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
600 g (21.18 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
36
1, 2 or 3-phase switching power
supply 230-400-500 Vac output
power 240 W
115
(4.53 in)
• Single-phase, 2-phase and 3-phase input 185...550 Vac
• High reliability and immunity against over voltage due to failures on
AC line
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
E203601
NOTES
BLOCK DIAGRAM
ORing diode only on "P" and "G" version
VERSIONS
L1
(L)
L2
(N)
AC
FILTER
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) 550 Vdc max for UL508
(3) Over 50°C (122°F) apply a derating of about 3 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version CSW241G is not suitable for SELV applications
Output 24 Vdc 10 A
Output 12…15 Vdc 16...15 A
Output 48 Vdc 5 A redundant version
Output 72 Vdc 3.3 A redundant version
55
(2.17 in)
130
(5.12 in)
L3
AC
AC
+
+
+
+
+
–
–
–
PE
PWM
Cod. XCSW241C
CSW241C
Cod. XCSW241B
Cod. XCSW241DP
Cod. XCSW241G
CSW241B
CSW241DP (1)
CSW241G (1) (5)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 230 / 400 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
1-2-3x 230-400-500 Vac (range 185…550 Vac / 270…770 Vdc) (2)
47...63 Hz
2A/1A
< 20 A
> 0.65
–
circuit breaker: 2-3x 6 A C characteristic - fuse: 2-3x T 6.3 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 230 / 400 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
24...27.5 Vdc
10 A @ 50°C (3)
12…15 Vdc
48 Vdc
72 Vdc
12…15 Vdc
45…55 Vdc
72…85 Vdc
16 A @ 12 Vdc / 15 A @
5 A @ 50°C (3)
3,5 A (3)
15 Vdc
6 A for >6 s
5 A for >6 s
15 A for >6 s
20…18 A for >6 s
with Uout >90% Un (4)
with Uout >90% Un (4)
with Uout >90% Un (4)
with Uout >90% Un (4)
38 A for 0.5 s (4)
34 A A for 0.5 s (4)
18 A for 0.5 s (4)
13 A for 0.5 s (4)
< 1%
< 1%
< 1%
< 1%
≤ 100 mVpp
≤ 100 mVpp
100 mVpp
≤ 100 mVpp
>15 ms / >100 ms
>15 ms / >100 ms
>15 ms / >100 ms
>15 ms / >100 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
21.6 Vdc
10.8 Vdc
43.2 Vdc
64,8 Vdc
possible
possible
possible
possible
factory provided with internal
factory provided with internal
possible with external ORing
possible with external ORing
diode
diode
ORing diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac)
Dissipated power (Uin 230 / 400 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>91% / >92%
24 W / 21 W
>89% / >90%
>91% / >92%
>92% / >93%
22 W / 20 W
24 W / 21 W
22 W / 19 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
1 kg (35.3 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
37
1, 2 or 3-phase switching power
supply 230-400-500 Vac
output power 480 W
• Single-phase, 2-phase and 3-phase input 185...550 Vac
• High reliability and immunity against over voltage due to failures on
AC line
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
140
(5.52 in)
E203601
73
(2.88 in)
NOTES
137
(5.40 in)
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) 550 Vdc max for UL508
(3) Over 45°C (113°F) apply a derating of about 16 W/°C
(4 For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version with 72 V output is not suitable for SELV applications
VERSIONS
Output 24 Vdc 20 A
Output 12…15 Vdc 40 A
Output 48 Vdc 10 A
Output 72 Vdc 6 A
Cod. XCSW481C
CSW481C
Cod. XCSW481D
XCSW481G
CSW481D
CSW481G (1) (5)
INPUT
Input rated voltage
Frequency
Current @ Iout max. (Uin 230 / 400 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
1-2-3x 230-400-500 Vac (range 187…550 Vac / 250…725 Vdc) (2)
47...63 Hz
2.2 A / 1 A
<20 A / <40 A
> 0.95
–
circuit breaker: 2-3x 6 A C characteristic - fuse: 2-3x T 6.3 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 230 / 400 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23,3...27,5 Vdc
20 A @ 45°C (3)
28 A for >5 s
with Uout >90%Un (4)
50 A for 0,3 s (4)
< 1%
≤ 100 mVpp
>20 ms / >20 ms
48 Vdc
72 Vdc
45…55 Vdc
72…85 Vdc
10 A @ 45°C (3)
6 A @ 45°C (3)
14 A for >5 s
9 A for >5 s
with Uout >90%Un (4)
with Uout >90%Un (4)
25 A for 0,3 s (4)
12 A for 0,3 s (4)
< 1%
< 1%
≤ 100 mVpp
≤ 100 mVpp
>20 ms / >20 ms
>20 ms / >20 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
21.6 Vdc
43.2 Vdc
64,8 Vdc
possible
possible
possible
factory provided with internal
factory provided with internal
possible with external ORing
diode
ORing diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 230 / 400 Vac)
Dissipated power (Uin 230 / 400 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>92% / >92%
42 W / 42 W
>92% / >92%
>91% / >91%
42 W / 42 W
42 W / 42 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium and stainless steel
1 kg (35.3 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
38
TRIPLE POWER
DIN-rail 3-phase switching power supplies specifically designed for applications in industrial
automation control panels.
They can deliver over +50% of the nominal current for a sustained period keeping a stable output
voltage.
The alarm contact is controlled by a voltage threshold and it switches when the voltage drops below
90% of the rated value.
Thanks to these features and to the numerous international certifications, this series of
power supplies allows engineers to meet all the requirements of the new EN 60204-1
Machinery Directive, to enable the protection devices connected to the output to trigger quickly, safely
and selectively, thus ensuring continuity of service to the other parts of the system.
Suggested uses
• Applications in machinery automation requiring high levels of reliability in terms of control and safety
voltage
• In applications requiring selectivity of surge protection devices on DC lines
• Applications in industrial automation
• Heavy duty uses
Main features
• Equipped with 340…550 Vac / 507…770 Vdc, they are suitable for use on all power lines.
• Their high efficiency reduces energy consumption and components’ operating temperature allowing
their use in small panels and under severe ambient conditions.
• Great backup power allowing to supply at least + 50% above the rated voltage for 5 seconds,
keeping output voltage constant and ensuring safety and reliability.
• The output voltage may be adjusted and is protected against the input of surges on the DC line and
is equipped with double electronic protection devices preventing damages to powered components
in the event of internal faults.
• Dimensioned short-circuit and overload protection supplying breakaway starting currents 150%
above the rated value required by heavy loads.
• Thermal protection prevents faults in the event of prolonged overloads at high ambient temperatures.
• Their design ensures excellent ventilation to internal components, very small dimensions and IP20
protection against accidental contacts in compliance with IEC529.
Integrated smart alarm contact
Activated when output voltage
decreases below 90% of rated value
Extremely compact dimensions
They are among the smallest on the
market, optimising the use of space in the
panel without compromising performance
Power boost
Very high
efficiency
The output power
reaches 120% of
the nominal value for
several minutes, up
to 150% during an
overload, and up to
250% in the event
of a short-circuit, to
enable the protection
devices connected to
the output to trigger
quickly, safely and
selectively, without
the use of additional
modules
Designed
to save energy and
reduce the working
temperature
Wide range
The widest range on the market, with power ratings
from 120 to 2400W and output voltages of 24, 48
and 72 V, for uses including powering special motors
39
Special power supplies for engines in DC,
Brushless, and relative drives
New 48Vdc, 72-85Vdc, and 110-180Vdc models
have been introduced, designed to reliably power
engines in DC. They:
• Supply peak power equal to even 4-5 times
the nominal current, which is required by the
engine during the peak phase
• Have an output stage protected from
overvoltage generated by the engines and
drives during braking, which could otherwise
cause malfunctions or cause the power supply
to lose control over output voltage stability
• Provide output voltage at 48Vdc, and 72-85Vdc.
By increasing the voltage of the engine power
supply, the same power can be obtained at
lower current, with notable advantages for
performance, engine construction, connection
wires, and drives.
New active electronic ASSIL protection
3-phase networks can cause reliability problems
for electronic devices due to various phenomena.
Simple activation of a protection or the
commutation of a load can generate holes in the
network and voltage peaks whose size depends
on several variables.
These damaging phenomena are governed by
the VDE0160-2 standard and cannot be resolved
using traditional passive protections (varistors,
NTC).
The solution is the active ASSIL circuit (Active
Surge Suppressor and Inrush Current Limiter).
A power semi-conductor “opens” the DC side in
less than 0.1 ms in the case that voltage exceeds
750V, preventing damaging voltage peaks from
reaching the convertor's MOSFET.
The protection circuit also serves to actively
limit the inrush current, which allows for precise
coordination of the overcurrent protections, as
well as eliminating undesirable bursts which can
occur when the network returns to its nominal
value after a voltage hole.
3-phase switching power
supply 400-500 Vac
output power 480 W
• 3-phase input 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
140
(5.52 in)
E203601
73
(2.88 in)
NOTES
137
(5.40 in)
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(3) Over 50°C (122°F) apply a derating of about 6 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
VERSIONS
Output 24 Vdc 20 A
Output 12…15 Vdc 40 A
Output 48 Vdc 10 A
Output 72 Vdc 6 A
Cod. XCSG481C
CSG481C (5)
—
—
—
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 400 / 500 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
3x 400–500 Vac (range 340…550 Vac)
47...63 Hz
1,2 A / 0,8 A
<40 A
> 0,95
—
circuit breaker: 3x 6 A C characteristic - fuse: 3x T 6,3 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 400 / 500 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
23,3...27,5 Vdc
20 A @ 45°C (3)
28 A for >5 s with Uout
>90%Un (4)
50 A for 0,3 s (4)
< 1%
≤ 100 mVpp
>50 ms / >50 ms
hiccup at the overload limit with auto reset / over temperature protection (3)
“DC OK” green LED / “DC OK” alarm contact
21,6 Vdc
possible
possible with external ORing
diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac)
Dissipated power (Uin 400 / 500 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>93% / >92%
36 W / 42 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
4 mm² fixed screw type
aluminium
1 kg (35.3 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
40
3-phase switching power
supply 400-500 Vac
output power 500 W
80
(3.15 in)
E203601
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(1) Version available upon request; for information call our sales
department, local agent or representative
(3) Over 50°C (122°F) apply a derating of about 6 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version CSG500G is not suitable for SELV applications
VERSIONS
Output 24 Vdc 20 A
Output 12…15 Vdc 40 A
Output 48 Vdc 10 A redundant version
Output 72 Vdc 6.7 A redundant version
139
(5.48 in)
ORing circuit only on "D" and "G" version
L1
L3
AC
FILTER
L2
AC
AC
+
+
+
A.S.S.I.L.
• 3-phase input 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
• Input protected by ASSIL circuit
(Surge Suppressor and Inrush Limiter)
127
(5 in)
+
+
–
–
–
PWM
PE
DC OK
Cod. XCSG500C
CSG500C
Special version for DC motors
Special version for DC motors
Cod. XCSG500D
Cod. XCSG500G
—
CSG500D (1)
CSG500G (1) (5)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 400 / 500 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
3x 400–500 Vac (range 340…550 Vac)
47...63 Hz
1 A / 0.6 A
< 35 A
> 0.75 with PFC
—
circuit breaker: 10 A characteristic - fuse: 3x T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 400 / 500 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
48 Vdc
72 Vdc
24...28 Vdc
45…55 Vdc
72…85 Vdc
20 A @ 50°C (3)
10 A @ 50°C (3)
6.7 A @ 50°C (3)
>30 A for >5 s
>15 A for >5 s
10 A for >5 s
with Uout >90% Un (4)
with Uout >90% Un (4)
with Uout >90% Un (4)
>60 A for 5 s (4)
>30 A for 5 s (4)
>20 A for 5 s (4)
< 0.5%
< 0.5%
< 1%
≤ 100 mVpp
≤ 100 mVpp
≤ 100 mVpp
>15 ms / >30 ms
>15 ms / >20 ms
>15 ms / >20 ms
hiccup at the overload limit with auto reset / over temperature protection / ASSIL circuit
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
<21.6 Vdc
<43.2 Vdc
<64,8 Vdc
possible
possible
possible
factory provided with internal
factory provided with internal
possible with external ORing
diode
ORing diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac)
Dissipated power (Uin 400 / 500 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>94% / >94%
30 W / 30 W
>94% / >94%
>95% / >95%
30 W / 30 W
26 W / 26 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
6 mm² fixed screw type
aluminium
1.3 kg (45.89 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
41
3-phase switching power
supply 400-500 Vac
output power 720 W
• 3-phase input 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
• Input protected by ASSIL circuit
(Surge Suppressor and Inrush Limiter)
127
(5.99 in)
80
(3.15 in)
E203601
139
(5.47 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(1) Version available upon request; for information call our sales
department, local agent or representative
(3) Over 50°C (122°F) apply a derating of about 6 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
ORing circuit only on "D" and "G" version
L3
FILTER
L2
AC
AC
AC
+
+
+
A.S.S.I.L.
L1
+
+
–
–
–
PWM
PE
DC OK
Special version for DC motors
VERSIONS
Output 24 Vdc 30 A
Output 12…15 Vdc 60 A
Output 48 Vdc 15 A redundant version
Output 72 Vdc 10 A redundant version
Cod. XCSG720C
CSG720C
(1)
CSG720D
(1)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 400 / 500 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
3x 400–500 Vac (range 340…550 Vac )
47...63 Hz
1.4 A / 1.1 A
< 30 A
> 0.75
—
circuit breaker: 3x 10 A C characteristic - fuse: 3x T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 400 / 500 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
48 Vdc
24…28 Vdc
45…55 Vdc
30 A @ 50°C (3)
15 A @ 50°C (3)
45 A for >5 s
22.5 A for >5 s
with Uout >90% Un (4)
with Uout >90% Un (4)
>80 A for 1.5 s (4)
>45 A for 1.5 s (4)
< 1%
< 1%
100 mVpp
100 mVpp
>10 ms / >15 ms
>10 ms / >15 ms
hiccup at the overload limit with auto reset / over temperature protection / ASSIL circuit
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
<21.6 Vdc
<43.2 Vdc
possible
possible
factory provided with internal
possible with external ORing
diode
ORing diod
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac)
Dissipated power (Uin 400 / 500 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>92% / >92%
60 W / 60 W
>93% / >93%
55 W / 55 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
6 mm² fixed screw type
aluminium
1.3 kg (45.86 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
42
3-phase switching power
supply 400-500 Vac
output power 960 W
• 3-phase input 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
• Input protected by ASSIL circuit
(Surge Suppressor and Inrush Limiter)
127
(5.99 in)
80
(3.15 in)
E203601
139
(5.47 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
ORing circuit only on "D" and "G" version
L1
L3
FILTER
L2
AC
AC
AC
+
+
+
A.S.S.I.L.
(3) Over 50°C (122°F) apply a derating of about 18 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version CSG960G is not suitable for SELV applications
+
+
–
–
–
PWM
PE
DC OK
VERSIONS
Output 24 Vdc 40 A
Output 12...15 Vdc 80 A
Output 48 Vdc 20 A redundant version
Output 72 Vdc 13.3 A redundant version
Cod. XCSG960C
CSG960C
Special version for DC motors
Special version for DC motors
Cod. XCSG960D
Cod. XCSG960G
—
CSG960D
CSG960G (5)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 400 / 500 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
3x 400–500 Vac (range 340…550 Vac)
47...63 Hz
2.2 A / 1.1 A
< 20 A
> 0.65
—
circuit breaker: 3x 10 A C characteristic - fuse: 3x T 10 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 400 / 500 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
24…28 Vdc
40 A @ 50°C (3)
56 A for >5 s
with Uout >90% Un (4)
>90 A for 5 s (4)
< 1%
100 mVpp
>10 ms / >15 ms
48 Vdc
72 Vdc
45…55 Vdc
72…85 Vdc
20 A @ 50°C (3)
13.3 A @ 50°C (3)
28 A for >5 s
18.6 A for >5 s
with Uout >90% Un (4)
with Uout >90% Un (4)
>70 A for 5 s (4)
>30 A for 5 s (4)
< 1%
< 1%
100 mVpp
≤ 100 mVpp
>10 ms / >15 ms
>15 ms / >18 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED
<21.6 Vdc
<43.2 Vdc
<64,8 Vdc
possible
possible
possible
factory provided with internal
factory provided with internal
possible with external ORing
diode
ORing diode
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac)
Dissipated power (Uin 400 / 500 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>94% / >94%
61 W / 61 W
>94% / >94%
>92% / >92%
61 W / 61 W
85 W / 85 W
–20...+60°C, with derating over 50°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
2 kVac / 60 s
0.5 kVac / 60 s
EN50178, EN61558, EN60950, IEC950, UL508
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
6 mm² fixed screw type
aluminium
1,2 kg (70.55 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
43
3-phase switching power
supply 400-500 Vac
output power 2400 W
130
(5.1 in)
• 3-phase input 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in SELV and PELV circuits
UL pending
• Input protected by ASSIL circuit
(Surge Suppressor and Inrush Limiter)
234
(9.2 in)
105
(4.1 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(2) Version available upon request; for information call our sales
department, local agent or representative
(3) Over 45°C (113°F) apply a derating of about 40 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
ORing circuit only on "D" and "G" version
L3
AC
AC
+
+
+
PFC
FILTER
L2
AC
A.S.S.I.L.
L1
+
+
–
–
–
PWM
PE
DC OK
Microcontroller
Display & user
interface
Load share
controller
Remote current
measure
Special version for DC motors
VERSIONS
Output 12-15-24 Vdc 100 A redundant version
Output 24-48 Vdc 50 A redundant version
Cod. XCSG2401C
CSG2401C (2)
Cod. XCSG2401D
CSG2401D (2)
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 400 / 500 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
3x 400–500 Vac (range 340…550 Vac)
47...63 Hz
4.2 A / 3.5 A
< 2 A (with active inrush current limiter)
> 0.92
—
circuit breaker: 3x 10 A C characteristic - fuse: 3x T10 A
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 400 / 500 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
12-15-24 Vdc
24-48 Vdc
11.5…29 Vdc
23...56 Vdc
100 A @ 45°C (3)
50 A @ 45°C (3)
150 A for >5 s with Uout >90%
75 A for >5 s with Uout >90%
Un (4)
Un (4)
>150 A for 5 s (4)
>75 A for 5 s (4)
< 1%
< 1%
≤ 200 mVpp
≤ 200 mVpp
>10 ms / >10 ms
>10 ms / >10 ms
programmable (see on right side)
“DC OK” green LED / “DC OK” alarm contact / “Overload” red LED /
LCD display
programmable (see on right side)
possibile
possibile
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac)
Dissipated power (Uin 400 / 500 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>92% / >92%
>93% / >93%
200 W / 200 W
180 W / 180 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
1.5 kVac / 60 s
0.5 kVac / 60 s
EN60950, IEC950
EN 55011, EN 61000-3-2, EN61000-4-5
Surge immunity Level IV, VDE0160
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC529, EN60529
4-6 mm² fixed screw type
aluminium
2,8 kg (98,76 oz)
vertical on rail, allow 60 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
44
APPLICATIONS
Series CSG2401 has an internal microprocessor that
controls the many functions of the power supply, which can
be programmed thanks to a user-friendly menu activated by
4 buttons on the front and shown on the front display.
Front display: during normal operation, this shows the
output voltage value and current used by the load; during
programming, it allows for the choice of the various functions
available.
Input protection: the input circuit has been designed
to avoid the most common problems seen in 3-phase
networks. It therefore has:
1) a special ASSIL (Active Surge Suppressor and Inrush
Limiter) circuit to protect it against overvoltage in
accordance with VDE0160;
2) a PFC circuit failure (latched shutdown) circuit;
3) a system for controlling lack of phase that automatically
reduces output power;
4) an auto-restart switch-off system in the event of
overvoltage and undervoltage.
Output protection: limit current can be selected as between
10% and 100% of rated current; protection type against
overload and short circuit can be chosen from:
1) hiccup autoreset with limit current, equal to 150% of
rated current and ON/OFF time equal to 5 secs./10 secs.
(values can be altered manually);
2) constant power.
Output signals: in addition to the "DC OK” and “FAULT” LEDs,
the device also has:
1) an analogue signal 0...10V or 4...20mA that provides an
indication of current used by the load;
2) a programmable alarm contact able to signal and record
the exceeding of the various limits to a memory: output
voltage, input current, output overload, overtemperature
and other parameters that can be defined by programming.
Additional functions: the following functions are also
available:
1) battery charger: the acid lead battery charging function
can be selected;
2) remote sensing (sense): this allows for the monitoring
and compensation of voltage drops on long power supply
lines;
3) remote switch-off: the power supply can be switched off
and disabled from a remote position;
4) auxiliary voltage: auxiliary 12 Vdc is also available,
regardless of the main output voltage status;
5) temperature control: by connecting an external sensor
(NTC), the battery charge temperature can be controlled;
6) communication port: by means of an RS232
communication device, the power supply can be piloted
and monitored from a remote position.
3-phase switching power
supply 400-500 Vac
output power 2400 W
130
(5.1 in)
• 3-phase input 340...550 Vac or 2-phase with derating
• Short circuit, overload, over temperature, input and output
overvoltage protections
• High outrush current to guarantee downstream overcurrent
protections selectivity and to start-up heavy loads
• High efficiency and low dissipated power
• Suitable for applications in PELV circuits
UL pending
• Input protected by ASSIL circuit
(Surge Suppressor and Inrush Limiter)
234
(9.2 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
With DC input voltage, the output current must be derated by 30%
(2) Version available upon request; for information call our sales
department, local agent or representative
(3) Over 45°C (113°F) apply a derating of about 40 W/°C
(4) For this peak current, the output voltage does not drop
more than 10% of the nominal value, but the current value,
provided by the power supply also depends on the total line
resistance.
(5) Version CSG2401G and CSG2401R is not suitable for SELV
applications
VERSIONI
Output 72 Vdc 33 A redundant version (5)
Output 100-110-170 Vdc 14 A redundant version (5)
ORing circuit only on "D" and "G" version
L3
AC
AC
+
+
+
PFC
FILTER
L2
AC
A.S.S.I.L.
L1
+
+
–
–
–
PWM
PE
Display & user
interface
Load share
controller
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time (Uin 400 / 500 Vac)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
Cod. XCSG2401R
CSG2401R (5) (2)
3x 400–500 Vac (range 340…550 Vac)
47...63 Hz
4.2 A / 3.5 A
< 2 A (with active inrush current limiter)
> 0.92
—
circuit breaker: 3x 10 A C characteristic - fuse: 3x T10 A
72 Vdc
100-110-170 Vdc
50...87 Vdc
88...175 Vdc
33 A @ 45°C (3)
14 A @ 45°C (3)
50 A for >5 s with Uout>90%
21 A for >5 s with Uout>90%
Un (4)
Un (4)
>50 A for 5 s (4)
>21 A for 5 s (4)
< 1%
< 1%
≤ 200 mVpp
≤ 200 mVpp
>10 ms / >10 ms
>10 ms / >10 ms
programmable (see on right side)
“DC OK” green LED / “DC OK” alarm contact/ “Overload” red LED /
LCD display (see on right side)
programmable
possibile
possibile
GENERAL TECHNICAL DATA
Efficiency (Uin 400 / 500 Vac)
Dissipated power (Uin 400 / 500 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>92% / >92%
>92% / >92%
200 W / 200 W
200 W / 200 W
–20...+60°C, with derating over 45°C / over temperature protection (3)
3 kVac / 60 s SELV output (5)
1.5 kVac / 60 s
0.5 kVac / 60 s
EN60950, IEC950
EN 55011, EN 61000-3-2, EN61000-4-5
Surge immunity Level IV, VDE0160
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC529, EN60529
4 and 6 mm² screw type
aluminium
2,8 kg (98,76 oz)
vertical on rail, allow 60 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Remote current
measure
Special version for DC motors
Cod. XCSG2401G
CSG2401G (5) (2)
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
DC OK
Microcontroller
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max. (Uin 400 / 500 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
105
(4.1 in)
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
45
APPLICATIONS
Series CSG2401 has an internal microprocessor that
controls the many functions of the power supply, which can
be programmed thanks to a user-friendly menu activated by
4 buttons on the front and shown on the front display.
Front display: during normal operation, this shows the
output voltage value and current used by the load; during
programming, it allows for the choice of the various functions
available.
Input protection: the input circuit has been designed
to avoid the most common problems seen in 3-phase
networks. It therefore has:
1) a special ASSIL (Active Surge Suppressor and Inrush
Limiter) circuit to protect it against overvoltage in
accordance with VDE0160;
2) a PFC circuit failure (latched shutdown) circuit;
3) a system for controlling lack of phase that automatically
reduces output power;
4) an auto-restart switch-off system in the event of
overvoltage and undervoltage.
Output protection: limit current can be selected as between
10% and 100% of rated current; protection type against
overload and short circuit can be chosen from:
1) hiccup autoreset with limit current, equal to 150% of
rated current and ON/OFF time equal to 5 secs./10 secs.
(values can be altered manually);
2) constant power.
Output signals: in addition to the "DC OK” and “FAULT” LEDs,
the device also has:
1) an analogue signal 0...10V or 4...20mA that provides an
indication of current used by the load;
2) a programmable alarm contact able to signal and record
the exceeding of the various limits to a memory: output
voltage, input current, output overload, overtemperature
and other parameters that can be defined by programming.
Additional functions: the following functions are also
available:
1) battery charger: the acid lead battery charging function
can be selected;
2) remote sensing (sense): this allows for the monitoring
and compensation of voltage drops on long power supply
lines;
3) remote switch-off: the power supply can be switched off
and disabled from a remote position;
4) auxiliary voltage: auxiliary 12 Vdc is also available,
regardless of the main output voltage status;
5) temperature control: by connecting an external sensor
(NTC), the battery charge temperature can be controlled;
6) communication port: by means of an RS232
communication device, the power supply can be piloted
and monitored from a remote position.
DC/DC Insulated converters
output power 120 W
• DC wide range input
• Short circuit, overload, over temperature protection
• Compact design
115
(4.53 in)
128
(5.04 in)
39
(1.54 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Inrush current is measured with input supplied by a battery;
the current peak vary depending on the internal impedance of
the current source and depending on cables and connections
resistance.
(2) According to EN60950 insulation tests on input side must be
made only with DC instruments.
(3) Version available upon request; for information call our sales
department, local agent or representative.
VERSIONS
12 Vdc / 24 Vdc 5 A
12 Vdc / 48 Vdc 2.5 A
24 Vdc / 12 Vdc 7 A
24 Vdc / 24 Vdc 5 A
Cod. XCSA120BC
CSA120BC (3)
Cod. XCSA120BD
Cod. XCSA120CB
Cod. XCSA120CC
CSA120BD (3)
CSA120CB
CSA120CC
INPUT TECHNICAL DATA
Input rated voltage
Current @ Iout max.
Inrush peak current
Standby power
Internal protection fuse
External protection on AC line
Overvoltage input protection circuit
12 Vdc (range 10.5…18 Vdc) 12 Vdc (range 10.5…18 Vdc)
10 A ± 10%
12 A ±10%
< 60A / < 2ms (1)
< 60A / < 2ms (1)
<1.5 W @ 12 Vdc
<1.5 W @ 12 Vdc
T 20 A replaceable
≥25 A C characteristic
Passive varistor and active shutdown at 19 Vdc
24 Vdc (range 18…36 Vdc)
24 Vdc (range 18…36 Vdc)
5.1 A ±10%
5.8 A ±10%
< 110A / < 2ms (1)
< 90A /< 2ms (1)
<1 W @ 24 Vdc
<1.5 W @ 24 Vdc
T 10 A replaceable
≥13 A C characteristic
Passive varistor and active shutdown at 38 Vdc
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
24 Vdc
22.5...27.5 Vdc
5 A @ 24 Vdc
6.5 A
12 A for 300 ms
48 Vdc
45…55 Vdc
2.5 A @ 48 Vdc
3.4 A
5.8 A for 300 ms
12...15 Vdc
12...15 Vdc
7 A @ 12 Vdc
9.1 A
15 A for 300 ms
<0.5%
≤ 100 mVpp
<0.5%
≤ 100 mVpp
>1 ms
>2 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
—
possible
Redundant parallel connection
24 Vdc
22.5...27.5 Vdc
5 A @ 24 Vdc
6.5 A
12 A for 300 ms
<0.5%
≤ 150 mVpp
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 110 Vdc)
Dissipated power (Uin 110 Vdc)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
> 83%
<25 W
> 83%
<25 W
>87%
<16 W
–20...+50°C
2.1 kVdc / 60s (2)
1.41 kVdc / 60s (2)
0.75 kVdc / 60s (2)
IEC950, EN60950
EN50081-1, EN50082-2, EN61000-3-2
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
550 g (19.40 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
46
>87%
<18 W
DC/DC Insulated converters
output power 120 W
• DC wide range input
• Short circuit, overload, over temperature protection
• Compact design
115
(4.53 in)
128
(5.04 in)
39
(1.54 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Inrush current is measured with input supplied by a battery;
the current peak vary depending on the internal impedance
of the current source and depending on cables and
connections resistance.
(2) According to EN60950 insulation tests on input side must be
made only with DC instruments.
(3) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
48 Vdc / 12 Vdc 8 A
48 Vdc / 24 Vdc 5 A
Cod. XCSA120DB
CSA120DB (3)
Cod. XCSA120DC
CSA120DC
INPUT TECHNICAL DATA
Input rated voltage
Current @ Iout max.
Inrush peak current
Standby power
Internal protection fuse
External protection on AC line
Overvoltage input protection circuit
48 Vdc (range 36…72 Vdc)
2.8 A ±10%
< 120A / < 2ms (1)
<2 W @ 48 Vdc
48 Vdc (range 36…72 Vdc)
2.8 A ±10%
< 120A / < 2ms (1)
<2 W @ 48 Vdc
T 5 A replaceable
≥6 A C characteristic
Passive varistor and active shutdown at 76 Vdc
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
12...15 Vdc
12...15 Vdc
8 A @ 12 Vdc
12 A
18 A for 300 ms
<0.5%
≤ 100 mVpp
2 ms
24 Vdc
22.5...27.5 Vdc
5A @ 24 Vdc
6.5 A
13 A for 300 ms
<0.5%
≤ 200 mVpp
4.5 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED
—
possible
Redundant parallel connection
possible with external ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 110 Vdc)
Dissipated power (Uin 110 Vdc)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>89%
<17 W
>90%
<13 W
–20...+60°C, with derating over 50°C
2.1 kVdc / 60s (2)
1.41 kVdc / 60s (2)
0.75 kVdc / 60s (2)
IEC950, EN60950
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-5-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
550 g (19.40 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
47
DC/DC Insulated converters
output power 240 W
• DC wide range input
• Short circuit, overload, over temperature protection
• Already preset with internal ORing diode for redundant
connection
• Compact design
140
(5.51 in)
NOTE:
also the power supplies CSD, CSF30, CSF85
and CSF120 series can be supplied in DC 110 V
135
(5.32 in)
63.5
(2.5 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) Inrush current is measured with input supplied by a battery;
the current peak vary depending on the internal impedance of
the current source and depending on cables and connections
resistance.
(2) Over 50°C (122°F) apply a derating -6 W/°C, max 60°C
(3) According to EN60950 insulation tests on input side must be
made only with DC instruments.
VERSIONS
110 Vdc / 24 Vdc 10 A
110 Vdc / 24 Vdc 10 A redundant
Cod. XCSA240FC
—
CSA240FC
INPUT TECHNICAL DATA
Input rated voltage
Current @ Iout max.
Inrush peak current
Standby power
Internal protection fuse
External protection on AC line
Overvoltage input protection circuit
110 Vdc (range 100...130 Vdc)
2.4 A ±10%
< 150A / < 2ms (1)
<3.4 W @ 110 Vdc
T 5 A replaceable
≥6 A C characteristic
Passive varistor and active
shutdown at 136 Vdc
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 110 Vdc)
Overload / short circuit protections
Status display
Alarm contact threshold
Parallel connection
Redundant parallel connection
24 Vdc
22.7…27 Vdc
10 A @ 50°C (2)
15 A
21 A for 300 ms
<1.5%
≤ 100 mVpp
>4 ms
hiccup at the overload limit with auto reset / over temperature protection
“DC OK” green LED / “DC OK” alarm contact / “Overload” red LED
—
possible
factory provided with internal
ORing diode
GENERAL TECHNICAL DATA
Efficiency (Uin 110 Vdc)
Dissipated power (Uin 110 Vdc)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>89%
<28 W
–20...+60°C, with derating over 50°C (2)
2.1 kVdc / 60s
(3)
1.41 kVdc / 60s
(3)
0.75 kVdc / 60s
(3)
IEC950, EN60950
EN61000-6-2, EN61000-6-4, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-5-5, EN61000-4-6, EN61000-4-11
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,,
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
800 g (28.24 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
48
Adjustable linear power
supply input 24 Vac
• Adjustable output voltage 1.2...24 Vdc
• Output current 1.5 and 5 A
• Short circuit, overload, over temperature protection
130
(5.10 in)
43
(1.70 in)
118
(4.60 in)
37
(1.50 in)
74
(2.90 in)
NOTES
115
(4.50 in)
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(1) See “Applications”
VERSIONS
Cod. XCL1R
CL1R
Output 1.2 A
Output 5 A
APPLICATIONS
Cod. XCL5R
CL5R
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max.
Internal protection fuse
External protection on AC line
9…26 Vac (see Tab. 1)
50...60 Hz
2,5 A
T 3 A replaceable
MCB: 4 A C characteristic - fuse T 4 A
6A
T 10 A replaceable
MCB: 10 A C characteristic - fusibilie T 10 A
1.2...24 Vdc
(see Tab. 1 and Tab. 2)
0.3...1.5 A (see Tab. 2)
—
1.2...24 Vdc
(see Tab. 1 and Tab. 2)
0.8...5 A (see Tab. 2)
—
OUTPUT TECHNICAL DATA
Output rated voltage
Output adjustable range
Continuous current
Overload limit
Load regulation
Ripple @ nominal ratings
Hold up time @ In
Overload / short circuit protections
Status display
< 1%
< 50 mVpp @ 24 Vac
>20 ms
constant current, limit current, auto reset / over temperature protection
“DC OK” green LED
(1) CL1R and CL5R give the rated
performances if fed by a voltage between 24 and 27 Vac, as
indicated on Tab. 1; with input
voltage between 24 and 27 Vac,
the maximum output current for
output voltages lower than 24 Vdc
are indicted on Tab. 2; to achieve
a good voltage stabilization and low
ripple, linear power supplies must
be fed with an input voltage higher
than output voltage, while if they are
supplied with 24 Vac, and adjusted
for 24 Vdc output, when rated current is supplied, the ripple increases
and voltage stabilization decreases;
input voltages higher than 27 Vac
increases power dissipation and
increases operating temperature of
the component, and might cause
thermal protection shut down.
The products are preadjusted to
Vout 24 Vdc with Vin 26 Vac.
GENERAL TECHNICAL DATA
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Reference Standards
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
–20...+45°C / over temperature protection (1)
not insulated
0.5 kVac / 60 s
0.5 kVac / 60 s
IEC 664-1, DIN VDE
EN50081-1, EN61000-6-4
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
II / 2
IP 00 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
aluminium
120 g (4.23 oz)
350 g (12.35 oz)
vertical on rail, allow 20 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
INPUT
(Vac)
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
—
Uout max.
(Vdc)
Iout max (A)
XCL1R
Iout max (A)
XCL5R
INPUT
(Vac)
Uout max.
(Vdc)
Iout max (A)
XCL1R
Iout max (A)
XCL5R
24...27
24
1.5
5
24
24
1.5
5
16...18
15
1.5
5
24
15
0.8
2.5
14...16
12
1.5
5
24
12
0.7
2
12...14
10
1.5
5
24
10
0.5
1.5
12
9
1.5
5
24
9
0.45
1.3
9
5
1.5
5
24
5
0.3
0.8
Tab. 1 (see explanation on right side)
Tab. 2 (see explanation on right side)
49
The CL-R linear reguated power
supply series of CABUR is provided
with adjustable output and it can
satisfy all those needs related to
the feeding of small loads with
non-standard rated voltage and at
an extremely limited cost. It can
be mounted on the rail in whatever position, providing that enough
space for the free circulation of
the air remains for the cooling; the
CL1R model having an IP 00 protection degree, its use is intended
inside a protected enclosure. Even
if the power supply is protected
from over-current it is advisable to
respect the rated values shown in
table 1 and 2.
Filtered power supplies
without transformer with non
regulated output
77
(3.10 in)
• DIN rail mounting
• Suitable for rectifying 6 Vac to 20 Vac
• V output = Vac input x 1.41 (-1V)
12
(0.50 in)
93
(4.53 in)
70
(2.17 in)
45
(1.80 in)
NOTES
80
(5.12 in)
BLOCK DIAGRAM
(2) Version available upon request; for information call our sales
department, local agent or representative
(3) They can work with input from min. 6 Vac to 30 Vac max.,
the non regulated output voltage depends on the load and on
the variations of the input voltage supplied by the transformer
(4) They are protected from overcurrent by their input fuse
(except AR1 model); it is recommended to protect cables of the
output line with fuses of value coordinated with the current of
the load and cables.
VERSIONS
Output 1 A
Output 6 A
Cod. XAR1
AR1 (2)
Cod. XAR2
AR6
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ Iout max.
Internal protection fuse
External protection on AC line
6…20 Vac
50...60 Hz
1.2 A @ 20 Vac
not available
MCB: 1 A C characteristic - fuse T 1 A
7.2 A @ 20 Vac
T 8 A replaceable
MCB: 10 A C characteristic - fusibilie T 10 A
OUTPUT TECHNICAL DATA
Output voltage (without load)
Output voltage (full load)
Continuous current
Overload limit
Load regulation
Ripple @ nominal ratings
Hold up time @ In
Overload / short circuit protections
Status display
Parallel connection
Redundant parallel connection
Uout = (Uin x 1.41)
Uout = (Uin x 1.41) -2
1 A @ 20°C
1A
(3)
(3)
6 A @ 20°C
9A
—
≤ 10%
>20 ms
not available, insert external fuse (4)
“DC OK” green LED
—
—
GENERAL TECHNICAL DATA
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Reference Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
–20...+45°C / max 60°C
not insulated
0.5 kVac / 60 s
0.5 kVac / 60 s
IEC 664-1, DIN VDE
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
II / 2
IP 00 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
22 g (0.77 oz)
140 g (4,93 oz)
vertical on rail, allow 50 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
INPUT
(Vac)
OUTPUT
without load (Vdc)
OUTPUT
full load (Vdc)
20
28.7
24.2
18
25.4
21.4
15
21.2
17.2
12
17
15
9
12.7
8.7
6
8.5
4.5
50
APPLICATIONS
A rectified and filtered power supply is made with a rectifier bridge
and a filter capacitor, that converts
the alternating voltage into a continuous voltage. Since the power
supply unit is not regulated, the
output voltage varies considerably
according to the current required
by the load and according to the
±10% mains voltage variations.
The formula indicated in the
output specifications allows to
calculate the output voltage with
Zero load, with 50% load and full
load. This allows you to choose
the most suitable transformer for
your needs.
These units offer a low cost and
a reliable voltage source suitable for loads such as relays,
contactors, solenoid valves or
loads that can work with relatively high ripple and wide voltage
variations; in applications where
mains is unstable or troubled, it
might be not suitable to feed
microprocessor devices, analog converters, encoders and
electronic devices which are
sensitive to voltage variations.
Accessory for charging buffer
batteries
• Battery charger
• Allows to connect in redundant parallel two power supplies
• Suitable for power supplies up to 10 A
• Battery protection fuse
• Battery feedback protection diode
• Current charge limiting resistor
93
(3.66 in)
26
(1.02 in)
NOTES
80
(3.15 in)
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
rail clamp.
(1) The charging current is dependent on the battery type and
the required level of charge, it's about:
- 0,5A max @ 12Vdc battery
- 1A max @ 24Vdc battery
(2) The device do not avoid total discharge which always
shortens battery life.
OUTPUT
Max. 15A
VERSIONS
APPLICATIONS
Cod. XCSBC
CSBC
1. Battery charger
With this module is possible to
use a Cabur power supply as a
battery charger while it is feeding
the load.
The diode provides decoupling
between the battery and the
power supply; the resistance limits
the current charge limiting power
supply output current and assuring longer life to the battery. The
F1 fuse protects the battery and
its wiring against short circuit.
The next picture shows the connections.
GENERAL TECHNICAL DATA
Power supply rated voltage
Power supply rated current
Load rated voltage
Load max current
Charge current limitation
Battery disconnecting voltage
IN/OUT drop voltage
Battery protection fuse
Protections
Alarm signal
Operating temperature range
Reference Standards
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
6...30 Vdc
>3A
6...29.5 Vdc
10 A
(1)
not available
0.5 V
F1 = T 6.3 A / F2 = T 1 A
battery short circuit /overload (2)
—
–10...+50°C
IEC 664-1, DIN VDE
II / 2
IP 20 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
80 g (2.82 oz)
vertical on rail, adjacent
2. Parallel connection of power
supplies
It is possible to use this module
also to connect two power supplies in parallel, not provided with
output decoupling diode, eliminating “Fuse 2” in series to charging
current limiting resistor.
The next picture shows the connections.
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
1. Battery charger
L
2. Parallel connection of power supplies
AC
GND
N
+
(A)
AC
(B)
BATTERY
+
–
(C)
CSBC
+
–
–
+
IN
+
+
–
–
L
AC
GND
N
OUT
AC
–
AC
+
GND
–
AC
(A) Power supply
(B) Battery
(C) CSBC
+
+
–
(C)
CSBC
+
–
(A)
IN
(A)
–
(A) Power supply
(C) CSBC
51
+
+
–
–
OUT
Accessory for charging and
controlling buffer batteries
115
(4.53 in)
• Suitable for power supply with adjustable output
• Suitable for lead batteries
• Suitable for charging batteries while feeding loads
• Battery protection fuse
• “Deep discharge” battery protection
• Status display LED and failure contact
55
(2.17 in)
NOTES
130
(5.12 in)
Items sold until seel-out, will be replaced by
XCSU240S from April 2014
BLOCK DIAGRAM
The depth dimension includes the DIN rail clamp.
(A) = Power Supply
(B) = Battery
(C) = CS-UPS
VERSIONS
OUTPUT
Max. 15A
Cod. XCSUPS1
CS-UPS1
Output 24 Vdc
Output 12 Vdc
Cod. XCSUPS2
CS-UPS2
GENERAL TECHNICAL DATA
Power supply input voltage
Power supply rated current
Load rated voltage
Max load current
Charging current
Battery disconnection voltage
IN/OUT voltage drop
Battery protection fuse
Protections
Alarm signals
26...28.5 Vdc
≥3A
26...28 Vdc
10 A
selectable 2 A or 4 A
≤ 18 Vdc ±0.5V
Power supply OK:
Battery OK
Battery LOW
Load OK
Battery reverse polarity
Operating temperature range
EMC Standards
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
12...15 Vdc
≥3A
10...15 Vdc
10 A
selectable 2 A or 4 A
≤ 9.2 Vdc ±0.5V
0.4 V
T 15 A 42 V blade type
Reverse polarity, short circuit, battery overload, battery deep discharge
SPDT 24 V / 1 A
green LED
red LED
yellow LED
green LED
–10...+50°C
IEC 664-1, DIN VDE
II / 2
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
300 g (10.58 oz)
vertical on rail, adjacent
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Example 1:
XCSF120C + XCSUPS1 + batteria
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Example 2:
XCSF120C + XCSUPS1 + XCSBP30Y
52
APPLICATIONS
All power supplies with adjustable output
voltage to +15% of rated voltage can be
used as lead battery chargers, suitable to
be used as back up supply in case of AC
line breakdown.
The CS-UPS-1 circuit regulate the
current charging the battery, and it is
possible to set it up to 2A or 4A charging
current ; CS- UPS1 disconnects the load
form the battery whenever the battery
voltage drops under 19Vdc, to avoid
total discharge which always shortens
battery life.
The module is provided with a fuse
protecting the battery and its cable to
prevent fire risk in case in case of short
circuit. The module is provided with the
following leds diplay:
PS OK: The green LED is on when the
power supply feeding the CS-UPS1 is
OK and the load is supplied by the power
supply while the battery is continuously
charged.
LOAD OK: Yellow LED is on when
CS-UPS1 feeds the load.
BATT. OK: Green LED is on when
the power supply is turned OFF or
disconnected and indicates that the
battery is connected and can feed the
load.
BATT. LOW: Red LED on when the
battery is low or discharged.
REVERSE BATTERY: Red LED is on
when battery is connected with reverse
polarity.
Alarm contact: a relay with an SPDT
contact 1A/24V switches when the load
is no more supplied by the power supply
and then is supplied by the battery. This
contact allows to get a remote warning
on the status of the system even in the
case that the power supply is turned OFF
or damaged, or non more supplied for
any reasons.
Accessory for charging and
controlling buffer batteries
• Suitable for lead and NiMH batteries
88
(3.46 in)
• Suitable for 12 or 24V battery with current load up to 3 A
• High efficiency and low dissipated power
• Compact dimensions
Available from March 2014
• Connected to a power supply, provides power to the load and keeps
the battery in buffer
70
(2.76 in)
NOTES
The depth dimension includes the DIN rail clamp.
(1) Product under development and available from March 2014,
the technical data and the image are to be considered
preliminary and subject to change.
BLOCK DIAGRAM
/'ZDy^hϳϬ^
(A)
(A)= Power Supply
(B)= Battery
(C)= XCSU70S
>
E
(C)
н
ƵĐŬZĞŐƵůĂƚŽƌĨŽƌĐŽŶƐƚĂŶƚǀŽůƚĂŐĞůŽĂĚ
н>K
Ͳ
W^K<
DŝĐƌŽĐŽŶƚƌŽůůĞƌ
ĨŽƌƐŵĂƌƚĐŚĂƌŐĞ
W^h
/E,
(B)
dΣ
н
ddZz
Ͳ
ƵĐŬZĞŐƵůĂƚŽƌĨŽƌƌĞŐƵůĂƚĞĚǀŽůƚĂŐĞďĂƚƚĞƌLJ
Ͳ>K
VERSIONS
Cod. XCSU070S
CSU070S
(1)
INPUT TECHNICAL DATA
Input voltage
Maximum input current
Consumption without load
12-24 Vdc (range 10…16 Vdc / 20…29 Vdc)
3A
n.d.
OUTPUT TECHNICAL DATA
Load rated voltage
Current of the load
Status display
12-24 Vdc
3 A (max. 4.5 A for 5 s)
“Backup” alarm contact
“DC OK” green LED
“Alarm/Failure” red LED
O
BATTERY TECHNICAL DATA
Battery type
Nominal battery voltage
Maximum charge current
Backup delay
Protections
Lead-Acid, NiMH
12 or 24 Vdc
0.5 A
n.d.
Reverse polarity, short circuit, battery overload, battery deep discharge
GENERAL TECHNICAL DATA
Efficiency
Dissipated power
Operating temperature range
Input / output isolation
Input / ground isolation
Output / ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>90%
—
–20...+60°C
0.5 kVac / 60 s
0.5 kVac / 60 s
0.5 kVac / 60 s
EN60950
EN61000-6-2, EN61000-6-4
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
II / 2
IP 20 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
250 g
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
53
APPLICATIONS
63
(2.48 in)
Accessory for charging and
controlling buffer batteries
• Suitable for lead and NiMH batteries
• Suitable for 12 or 24V battery battery with current load up to 10 A
• High efficiency and low dissipated power
• Compact dimensions
Available from April 2014
• Connected to a power supply, provides power to the load and keeps
the battery in buffer
NOTES
The depth dimension includes the DIN rail clamp.
(1) Product under development and available from March 2014,
the technical data and the image are to be considered
preliminary and subject to change.
BLOCK DIAGRAM
(A)
(A)= Power Supply
(B)= Battery
(C)= XCSU240S
>
E
(C)
н
н>K
Ͳ
W^K<
DŝĐƌŽĐŽŶƚƌŽůůĞƌ
ĨŽƌƐŵĂƌƚĐŚĂƌŐĞ
W^h
dΣ
н
ddZz
Ͳ
ƵĐŬZĞŐƵůĂƚŽƌĨŽƌƌĞŐƵůĂƚĞĚǀŽůƚĂŐĞďĂƚƚĞƌLJ
Cod. XCSU240S
CSU240S
(1)
INPUT TECHNICAL DATA
Input voltage
Maximum input current
Consumption without load
12-24 Vdc (range 10…16 Vdc / 20…29 Vdc)
10 A
n.d.
OUTPUT TECHNICAL DATA
Load rated voltage
Current of the load
Status display
12-24 Vdc
10 A (max. 15 A for 5 s)
Alarm contact: normal operation (Ready)
Alarm contact: battery operation (Backup)
“DC OK” green LED
LED red alarm or backup failure
BATTERY TECHNICAL DATA
Battery type
Nominal battery voltage
Maximum charge current
Backup delay
Protections
Lead-Acid, NiMH
12 or 24 Vdc
2A
n.d.
Reverse polarity, short circuit, battery overload, battery deep discharge
GENERAL TECHNICAL DATA
Efficiency
Dissipated power
Operating temperature range
Input / output isolation
Input / ground isolation
Output / ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>90%
—
–20...+60°C
0.5 kVac / 60 s
0.5 kVac / 60 s
0.5 kVac / 60 s
EN60950
EN61000-6-2, EN61000-6-4
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
II / 2
IP 20 IEC 529, EN60529
4 mm² pluggable screw type (IN/OUT/BATT) e 0,75 mm² (signal)
aluminium
500 g
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
/E,
(B)
VERSIONS
ƵĐŬZĞŐƵůĂƚŽƌĨŽƌĐŽŶƐƚĂŶƚǀŽůƚĂŐĞůŽĂĚ
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
54
Ͳ>K
APPLICATIONS
Accessory for charging and
controlling buffer batteries
• Suitable for lead and NiMH batteries
• Suitable for 12 or 24V battery with currents load up to 20 A
• High efficiency and low dissipated power
• Compact dimensions
• Connected to a power supply, provides power to the load and keeps
the battery in buffer
Under development and available
from May 2014
NOTES
The depth dimension includes the DIN rail clamp.
(1) Product under development and available from April 2014, the
technical data and the image are to be considered preliminary
and subject to change.
BLOCK DIAGRAM
(A)
(A)= Power Supply
(B)= Battery
(C)= XCSU500S
>
E
(C)
н
ƵĐŬZĞŐƵůĂƚŽƌĨŽƌĐŽŶƐƚĂŶƚǀŽůƚĂŐĞůŽĂĚ
н>K
Ͳ
W^K<
DŝĐƌŽĐŽŶƚƌŽůůĞƌ
ĨŽƌƐŵĂƌƚĐŚĂƌŐĞ
W^h
dΣ
н
ddZz
VERSIONS
Ͳ
ƵĐŬZĞŐƵůĂƚŽƌĨŽƌƌĞŐƵůĂƚĞĚǀŽůƚĂŐĞďĂƚƚĞƌLJ
Cod. XCSU500S
CSU500S
(1)
INPUT TECHNICAL DATA
Input voltage
Maximum input current
Consumption without load
12-24 Vdc (range 10…16 Vdc / 20…29 Vdc)
20 A
<2 W
OUTPUT TECHNICAL DATA
Load rated voltage
Current of the load
Status display
12-24 Vdc
20 A (max. 30 A for 5 s)
Alarm contact: normal operation (Ready)
Alarm contact: battery operation (Backup)
“DC OK” green LED
Red LED for backup or failure alarm
BATTERY TECHNICAL DATA
Battery type
Nominal battery voltage
Maximum charge current
Backup delay
Protections
Lead-Acid, NiMH
12 or 24 Vdc
5A
n.d.
Reverse polarity, short circuit, battery overload, battery deep discharge
GENERAL TECHNICAL DATA
Efficiency
Dissipated power
Operating temperature range
Input / output isolation
Input / ground isolation
Output / ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>90%
—
–20...+60°C
0.5 kVac / 60 s
0.5 kVac / 60 s
0.5 kVac / 60 s
EN60950
EN61000-6-2, EN61000-6-4
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
II / 2
IP 20 IEC 529, EN60529
4 mm² pluggable screw type (IN/OUT/BATT) e 0,75 mm² (signal)
aluminium
500 g
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
/E,
(B)
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
55
Ͳ>K
APPLICATIONS
Batteries holder module
• 12 or 24 Vdc selectable output voltage
• Suitable for sealed lead rechargeable batteries
• Suitable for CSBC, CS-UPS, CSC75
• Suitable for DIN rail installation
113
(4.53 in)
55
(2.17 in)
NOTES
130
(5.12 in)
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
rail clamp.
(1) Into XCSBP30Y are necessary two batteries 8911012
VERSIONS
Batteries holder module (empty)
Battery (1)
APPLICATIONS
CSBP30Y
BAT12V1,2AH
Cod. XCSBP30Y
Cod. 8911012
GENERAL TECHNICAL DATA
Batteries type
Internal protection fuse
Setup type
Output voltage
Charging current max.
Discharging current max.
Operating temperature range
EMC Standards
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
2 sealed batteries 12 Vdc 1.2 Ah
15 A
parallel
12 Vdc 2.4 Ah
0.6 A
5A
series
24 Vdc 1.2 Ah
0.3 A
3A
–10...+50°C
IEC 664-1, DIN VDE
II / 2
IP 20 IEC 529, EN60529
2.5 mm² pluggable screw type
aluminium
1.2 kg (42,36 oz)
vertical on rail, adjacent
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Example 1:
XCSC120C + XCSBP30Y
Example 2:
XCSF120C + XCSUPS1 + XCSBP30Y
56
Switching power supply with
integrated battery charger
115
(4.54 in)
• Suitable for 12 Vdc loads and batteries
• Suitable for lead batteries
• Suitable for charging batteries while feeding loads
• Battery protection circuit
• “Deep discharge” battery protection
• Status display LED and failure contact
39
(1.53 in)
NOTES
128
(5.03 in)
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
(2) With 100...127 Vdc input voltage, constant output power and
Ta>45°C, the output current must be derated by 25%
(3) In addition to the current load, the device supplies about 0.8
A for battery charging
(4) Over 50°C (122°F) apply a derating -0.13 A/°C, max 60°C
VERSIONS
Output 12 Vdc 5 A
Output 24 Vdc 5 A
BATT.
Cod. XCSC120B
CSC120B
CSC120C
INPUT TECHNICAL DATA
Input rated voltage
Frequency
Current @ nominal Iout (Uin 120 /230 Vac)
Inrush peak current
Power factor
Internal protection fuse
External protection on AC line
120–230 Vac (range 90…264 Vac / 100…370 Vdc) (2)
47...63 Hz
2.0 A / 1.1 A ± 10%
< 20 A
> 0.6
T 3.15 A replaceable
circuit breaker: 4 A - C characteristic - fuse: T 3.15 A
OUTPUT TECHNICAL DATA
Output voltage with operating power supply
Output voltage with batteries
Continuous current
Overload limit
Short circuit peak current
Load regulation
Ripple @ nominal ratings
Hold up time @ In (Uin 120 / 230 Vac)
Overload / short circuit protections
Alarm signals
Max. charging current
12.5…15.5 Vdc
23…27.5 Vdc
12…14.4 Vdc
24…26.2 Vdc
7 A @ 50°C (3)
5 A @ 50°C (3)
>11 A for >30 s
>8 A for >30 s
>18 A for >50 ms
>12 A for >50 ms
< 1%
< 1%
80 mVpp
80 mVpp
>24 ms / >80 ms
>17 ms / >72 ms
with operating power supply: hiccup at the overload limit with auto reset
non operating power supply: auto resettable electronic fuse against battery short circuit
with non operating power supply: threshold-relay against battery deep discharge
"PSU OK" green LED / failure contact / "BATTERY" red LED
0.8 A (suitable for sealed lead batteries up to 15 Ah)
GENERAL TECHNICAL DATA
Efficiency (Uin 120 / 230 Vac)
Dissipated power (Uin 120 / 230 Vac)
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
>86% / >90%
>90%
21 W / 13 W
< 13 W
–20...+60°C, with derating over 50°C / over temperature protection (4)
1.5 kVac / 60 s SELV output
1.5 kVac / 60 s
0.5 kVac / 60 s
IEC950, EN60950
EN55011, EN61000-6-1
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
II / 2
IP 20 IEC 529 EN60529
2.5 mm² pluggable screw type
aluminium
500 g (17.65 oz)
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
APPLICATIONS
Cod. XCSC120C
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
–
57
Accessory for power supplies
redundant parallel connections
• Suitable for power supplies without Oring diodes
• Compact dimensions
• Three selectanle voltages 12, 24 and 48 Vdc
• 2 status/relays contacts
• Power supplied status LED
130
(5.12 in)
43
(1.69 in)
85
(3.35 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
rail clamp.
VERSIONS
Cod. XCSBD
CSBD
GENERAL TECHNICAL DATA
Power supply rated voltage
Power supply rated current
Load rated voltage
Load max current
IN/OUT drop voltage
Protections
Alarm signal
Operating temperature range
Reference Standards
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
12–24–48 Vdc selectable
15 A, max 30 A
12–24–48 Vdc selectable
15 A
0.7 V @ 15 A
—
2 contacts NA 2A @ 230 Vac
–20...+50°C
IEC 664-1, DIN VDE
II / 2
IP 00 IEC 529, EN60529
2.5 mm² fixed screw type
UL94V-0 plastic material
120 g (4.23 oz)
vertical on rail, adjacent
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
Block diagram
(A) Power supply
(B) CSBD
58
APPLICATIONS
This module allows the customer to
connect in redundant parallel two power
supplies not provided with built in Oring
diodes (output decoupling diodes); a
jumper bridge allows to select 12, 15,
24 or 48 Vdc operating voltage; each
channel is provided with status indication
led, status relay and contact for remote
failure alarm.
Accessory for power supplies
redundant parallel connections
(5.12 in)
110
• Suitable for connection of power supplies without ORing diodes
• Load voltages from 12 to 85 V with currents of up to 50 A
• Electronic redundancy controlled by CPU
• Failure alarm and unbalanced current alarm
• High efficiency and low dissipated power
• Compact dimensions
145
(3.35 in)
40
(1.69 in)
UL pending
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
rail clamp.
!"
#
#%&
$#!%&
VERSIONS
Cod. XCSR50U
CSR50U
GENERAL TECHNICAL DATA
Input voltage
Maximum input current
Load rated voltage
Load maximum current
IN/OUT voltage drop
Protections
Status display
Efficiency
Dissipated power
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
MTBF @ 25°C @ nominal ratings
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
12…85 Vdc
50 A
10,8…85 Vdc
50 A (max. 300 A picco)
0,2 V @ 50 A
reverse polarity, input overvoltage
green LED for input voltage control
red LED alarm for redundancy alarm
alarm contact for redundancy alarm (24V/1A)
LED bar for the control of the unbalance current
alarm contact for the control of the unbalance current
>98% (12 V / 50A)
10 W
–20...+50°C
0.5 kVac / 60 s
0.5 kVac / 60 s
0.5 kVac / 60 s
EN 60950
EN 61000-6-2, EN 61000-6-4
>500'000 h acc. to SN 29500 / >150'000 h acc. to MIL Std. HDBK 217F
,, / 2
IP 20 IEC 529, EN60529
removable screw terminals 16 mm² (IN / OUT) and 1.5 mm² (signal)
aluminium
200 g
vertical on rail, allow 10 mm spacing between adjacent components
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
-
59
APPLICATIONS
The CSR50U is an advanced, microprocessor-controlled module
used for redundant parallel connections of two DC power supplies
in applications needing higher reliability than provided by common
passive ORing modules with diodes to isolate the outputs of the
two power supplies.
The CSR50U comes with a current measurement sensor on each
input to detect the correct supplied by the two power supplies and
signal an alarm when the current supplied is unbalanced. An imbalance greater than 60% in the supply current is a certain indicator
that one of the power supplies is failing. Detecting this situation
and signalling an alarm with an SPST contact allows preventative
maintenance to take place and increases the system's reliability.
In redundant systems where an imbalance in the supply is not
controlled, it is not possible to monitor the correct supply of current
from the two power sources. This setup permits a situation in which
the current is supplied by only one power source, which then is
forced to work under greater stress. Furthermore, the power source
which supplies less current (or no current) may not trigger an alarm
in certain conditions.
The CSR50U allows two identical power supplies to be connected
for a total current output of 50 A and overall voltage from 12 to
85 Vdc.
Thanks to the ORing and isolation between the two power supplies
with the microprocessor-controlled MOSFET, the power dissipated
is one tenth that of redundant modules with diodes.
In addition, CSR50Us can be connected together to obtain redundancy of more than two systems.
The CSR50U provides status signals on:
• a fault or power loss in one of the two power sources
• unbalanced current supplies greater than 60%
MBC2K
Motor brake controller
The MBC2K is a device controlled by a microprocessor, that can automatically insert a power
resistor into the DC BUS for braking a motor fed by the same DC Bus through a motor drive. The
function of the MBC2K is to dissipate the energy delivered by the motor in an external resistor
thus damping the resulting overvoltage on the DC Bus.
On top of that the MBC2K provides several protections to ensure reliable operation.
MBC2K can be connected to any DC Bus within 24Vdc and 100Vdc. The simplified application
diagram is shown in Figure 1, while the unit front view with all its controls is shown in Figure 2.
Up to 4 MBC2K units can be connected in parallel to increase the braking power up to 8kW max.
The MBC2K is provided with a 2.5 digits 7 segments LED display, used to display the DC Bus
voltage (with +/- 1V accuracy), to help the user during the setup phase and/or to show error
messages.
MBC2K Setup
The MBC2K unit needs to be set up before operating.
The setup phase consists of 3 menu pages. The user can navigate through the menu pages
by pressing the MENU button and the values on each menu page can be changed by pressing
SET / RESET button.
The three menu pages are the following:
a) Brake intervention threshold (VTH) setup
b) Hysteresis around the brake intervention threshold voltage
c) Master / Slave mode, used for parallel connection up to four modules.
MBC2K protection and error codes
The MBC2K unit integrates several active protections to guarantee reliable operations in normal
conditions. As soon as a faulty event is detected the MBC2K power stage is switched off so
that no uncontrolled current flow through the brake resistor is possible. A fault condition is
indicated by the continuous blinking of the Alarm LED. Remote sensing of the status of the
MBC2K unit is possible thanks to the Alarm relay dry contact. To help the user to understand
which faulty event occurred, an error code is displayed on the 7 segments LED display. Every
protection is latched, so that to put back the MBC2K unit in “operation mode”.
Figure 1: Simplified application diagram
Parallel connection up to 4 MBC2K units
The MBC2K brake controller provides a feature allowing connecting up to 4 identical MBC2K
units to increase the peak braking power up to 8kW. In any case every MBC2K unit can
handle only 2kW of peak braking power therefore every MBC2K unit need its own 2kW brake
resistor.
To realize this feature the MBC2K is equipped with a Synchronization Bus used to synchronize
the operation of all the units connected to the synchronization bus. The principle of operation
relies on one MBC2K unit configured as the master and others MBC2K units (up to 3)
configured as slave.
The master measures the DC Bus voltage and decides when to insert its brake resistor in the
circuit; on top of that it sends a command on the synchronization bus.
The slaves connected on the synchronization bus are waiting for the command sent by the
master; when they receive the command they insert their brake resistors in the circuit too.
Please note that even when the MBC2K is configured in slave mode, all its circuits protections
are functional.
"'
()**)
"'
)+
"'
'&
##&!
,
#,
-,.
1. SET/RESET button: used to reset the protections and to change setup values in setup mode.
2. MENU button: used to enter into setup mode and to navigate through menu pages.
3. Synchronization bus connector: used to parallel up to 4 units.
4. Resistor temperature sensor connector: used to connect an optional brake resistor
temperature sensor.
5. Alarm dry contact connector: an SPDT contact provide remote failure signal.
6. Brake resistor connector: used to connect the brake resistor wires 2.5mm²
7. DC Bus connector: used to connect the MBC2K unit to the power supply Bus (24….100Vdc).
8. Protective earth (PE) connection: to connect the module to the protective earth.
9. LED display 100’s indicator: used to display numbers >99 on 2 digits; when this indicator is lit
and the display shows “03” this means 103V.
10. Brake indicator LED: used to display braking activity; when lit it means that there is a current
flow through the brake resistor.
11. 2.5 digits 7-segment display: in operating mode it shows the voltage measured on the DC
Bus (accuracy +/- 1V); it’s used also to show menu items and error codes.
12. Alarm LED: used to indicate a fault condition of the unit.
Figure 2: MBC2K Front View
60
Motor brake controller
• 20 threshold levels with automatic activation
• Each module can drive 2kW bracking power
• It is possible to connect up to four modules master/slave to
get 8kW total braking power
• Symple functions programming and set up
• Control of the temperature of the braking resistor
115
(4.53 in)
39
(1.54 in)
128
(5.04 in)
NOTES
BLOCK DIAGRAM
The depth dimension includes the terminal blocks and the DIN
clamp.
Alarm
Synchronization
bus driver and
receiver
DC IN
DC/DC power
supply
VERSIONS
R Brake
Sync T sense
Microprocessor
Display and
buttons
Mosfet
driver and
short circuit
protection
Cod. XMBC2K
MBC2K
INPUT TECHNICAL DATA
Nominal DC BUS voltage range
Maximum braking current
Brake activation voltage
Brake voltage hysteresis
User interface
Protections
Parallel connection
24…100 Vdc
50 A for 1 s
27….106 V, threshold adjustable in 20 steps
3 V o 6 V selectable
2 setup push buttons (SET/RESET and MENU)
2 x 7 segment LED displays
1 LED for general alarm indication
1 SPDT dry contact for general alarm remote warning
Undervoltage on DC BUS < 22 Vdc
Overvoltage on DC BUS > 110 Vdc
Brake resistor overtemperature (if the temperature sensor is present)
Module Internal overtemperature > 90°C (194°F)
Brake resistor interrupted or not connected
Short circuit : braking current > 80 A
Overload : braking time > 1 s
Up to 4 units can be connected in parallel through synchronization bus for a total braking power
of 8kW (4 x 2kW braking resistors are needed)
GENERAL TECHNICAL DATA
Dissipated power
Operating temperature range
Input/output isolation
Input/ground isolation
Output/ground isolation
Standard/approvals
EMC Standards
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
Approx. weight
Mounting information
20 W
0...+70°C
—
500 Vac / 60s
—
IEC950, EN60950 for SELV use up to 60Vdc; using the MBC2K at voltages greater than 60Vdc is
not classifiable as SELV
EN55011 Class B
I/2
IP 20 IEC 529, EN60529
1.5 and 2.5 mm² pluggable screw type
aluminium
200 g
vertical on rail, allow 10 mm spacing between adjacent components
120 g
vertical on rail, adjacent
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
61
APPLICATIONS
The MBC2K is a device controlled by a
microprocessor, that can automatically
insert a power resistor into the DC BUS
for braking a motor fed by the same DC
Bus through a motor drive. The function
of the MBC2K is to dissipate the energy
delivered by the motor in an external
resistor thus damping the resulting overvoltage on the DC Bus
On top of that the MBC2K provides
several protections to ensure reliable
operation.
MBC2K can be connected to any DC Bus
within 24Vdc and 100Vdc. The simplified
application diagram is shown in Figure
1, while the unit front view with all its
controls is shown in Figure 2.
Up to 4 MBC2K units can be connected
in parallel to increase the braking power
up to 8kW max.
The MBC2K is provided with a 2.5 digits
7 segments LED display, used to display
the DC Bus voltage (with +/- 1V accuracy), to help the user during the setup
phase and/or to show error messages.
AC Surge Protection Devices
These are Surge Protection Devices (SPD ) that prevent transitional impulsive overvoltage,
conducted via the mains power supply, the earth network or signal networks, from damaging
electronic command and control systems and electronic appliances in general. Series BY7
protection devices limit dangerous overvoltage to standard levels tolerated by the appliances
intended for use in Overvoltage Category II or greater (impulsive overvoltage max. 2.5kV) in
zone protected from overvoltage B and C (Zones 1 and 2) if the plant does not have a lightning
arrester, in protection zone C (Zone 2) if the plant has a lightning arrester, and are SPD in
Test Class II as required by standards IEC1024, IEC1312-1, EN50083-1 in force (see figure
1 the following pages)
Where and how to use them
In accordance with current standards, series BY7 surge protection devices must be installed
on incoming power lines to electrical distribution and control and command boards for
automation, in order to guarantee immunity to the transistors of the equipment contained,
such as PLC, industrial PCs, power supplies, inverters, etc.. For command and control
boards, generally in Overvoltage Category II according to IEC EN 644-1 to be compliant
with EMC standards, maximum impulsive overvoltage applied to equipment must be below
2.5kV, as indeed is also required by EN61000-4-4, 4-5. If SPDs with residual overvoltage of
less than 2.5kV, which can be withstood by equipment, are not installed on command and
control boards, overvoltage may cause plant or machine failure or breakdown, with costs that
certainly exceed the cost of the SPDs. Installation of SDPs is also required, in any case, in
order to comply with EMC standards and CE marking of the board.
Performance
They consist of a wiring socket that can be assembled onto a DIN rail and a removable
protection module that contains the discharge, making it easy to disconnect the SPD during
insulation tests or for quick replacement at the end of its working life. They are able to
withstand ten 20kA impulses of Isc discharge current with impulse 8/20 and a single 40kA
impulse, which is statistically very rare. As required by the product regulations on the SPDs,
the BY7 series is equipped with an automatic thermal cut-off device able to disconnect the
line transformer in the event of failure, providing an indication of the failure discharge visible
on the front of the unit and via a clean contact. When, after numerous discharges and years
of service the module has deteriorated, it can be rapidly replaced by removing it from its base
socket and replacing it with another, identical one, without disconnecting the power supply.
Fuses and protection devices
BY7 series overvoltage dischargers have an incorporated device that disconnects the
transformer at the end of its working life (close to short circuit or short circuited). They must,
however, be fitted with protection against short circuit current upstream and differential
protection against indirect contact (generally already included in the installation). If installed
downstream of highly sensitive differential protection devices, we recommend using the
configuration with gas discharger (see layouts on the following pages). The diagrams below
illustrate an example protection connection according to priority type.
Continuity of services takes priority
Protection takes priority
62
Surge Protection Devices
picture 1
ZONE 0
ZONE 1
65 kA
4.5kV
ZONE 2
40 kA
2.5kV
Lightning protection zones
Zone 0 - Zone where items are subject to direct lightning
strikes or where an unattenuated electromagnetic field occurs
as a result of the strike.
Zone 1 - Zone where items are subject to low level direct
lightning strikes. The conducted impulse lightning currents and/
or switching surges are reduced compared with Zone 0.
Zone 2 - Remnants of lightning impulse currents and/or
switching surges are reduced compared with Zone 1.
Zone 3 - Surges, caused by oscillation effects, magnetic field
couplings and internal switching surges are reduced compared
with Zone 2
A - Sub Station
B - Main distribution board
C - Heavy machinery
D - Local distribution board
E - Light machinery
F - Workstation
G - Equipment
ZONE 3
< 10 kA
Example of connection for different networks
TN 3-phase system
TT 3-phase system
No. 3 ISPD14440 +
No. 1 ISPD1444G +
No. 1 screw jumper 9000394
No. 4 ISPD14440 +
No. 1 screw jumper 9000394
BLOCK DIAGRAM
BLOCK DIAGRAM
L1
L1
L2
L2
L3
L3
N
N
TN single phase system
No. 2 ISPD14275 +
No. 1 screw jumper 9000392
TT single phase system
No. 2 ISPD14275 +
No. 1 ISPD1425G +
No. 1 screw jumper 9000393
No. 1 ISPD14275 +
No. 1 ISPD1425G +
No. 1 screw jumper 9000392
BLOCK DIAGRAM
TT single phase system
BLOCK DIAGRAM
BLOCK DIAGRAM
L
L
L
N
N
N
63
Surge protection devices
• Rugged contacts
• Pluggable protection
• Efficiency status indicator on front panel
• Available screw jumpers for parallel conection
81
(3,18 in)
81
(3,18 in)
81
(3,18 in)
81
(3,18 in)
68
(2,67 in)
68
(2,67 in)
68
(2,67 in)
68
(2,67 in)
17,5
(0,68 in)
17,5
(0,68 in)
NOTES
17,5
(0,68 in)
17,5
(0,68 in)
BLOCK DIAGRAM
(1) When the termal protection disconnects the SPD, the
contacts 11-14 open and contacts 11-12 close
L/N
VERSIONS
L/N
N
11 14 12
11 14 12
N
Cod. ISPD14275
BY7-40/1-275
Cod. ISPD1425G
BY7-NPE/40-275
Cod. ISPD14440
BY7-40/1-440
Cod. ISPD1444G
BY7-NPE/40-440
II
TN-S; TN-C; TT; IT
MOV (Metal Oxide Varistor)
Un 230 Vac
Uc 275 Vac
Up ≤ 1.200 V
In 20 kA
Imax 40 kA
II
TN-S; TN-C; TT; IT
GDT (Gas Discharge T
Un 230 Vac
Uc 255 Vac
Up ≤ 1.800 V
In 30 kA
Imax 40 kA
II
TN-S; TN-C; TT; IT
MOV (Metal Oxide Varistor)
Un 400 Vac
Uc 440 Vac
Up ≤ 2.000 V
In 20 kA
Imax 40 kA
II
TN-S; TN-C; TT; IT
GDT (Gas Discharge Tube)
Un 400 Vac
Uc 440 Vac
Up ≤ 1.800 V
In 30 kA
Imax 40 kA
ELECTRICAL TECHNICAL DATA
Category
Type of network systems
Tecnology
Rated voltage
Maximum continuous voltage
Voltage protection level
Norminal discharge current (8/20)
Maximum discharge surge current (8/20)
GENERAL TECHNICAL DATA
Connection terminal
Response time
Operating temperature range
Status dispaly
Remote signal
Remote signal connection
Housing material
Protection degree
Colour
Packaging quantity
Approx. Weight
Mounting information
4 ... 25 mm² fixed screw type
ta < 25 nS
-40°C < T < 80°C
No
Green OK / Red FAILURE
No
SPDT 1 A/230 Vac (1)
No
1,5 mm² pluggable 6 A - 120 V
UL94V1
UL94V2
IP21
IP22
Blue
Yellow
1
2
95 g
135 g
vertical on rail, without spacing between adjacent components
Green OK / Red FAILURE
SPDT 1 A/230 Vac (1)
1,5 mm² pluggable 6 A - 120 V
UL94V0
IP20
Yellow
1
135 g
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Replacement varistor
Screw type jumper
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
2 poles
3 poles
4 poles
Cod. 9000392 (BP2)
Cod. 9000393 (BP3)
Cod. 9000394 (BP4)
64
No
No
No
UL94V3
IP23
Blue
3
95 g
Adjustable electronic
overcurrent protection
from 1…10 A / 24 Vdc
According to the new EN60204-1 Std. it is compulsory to protect wires on SELV-PELV lines against the
effects of surges. The standard requires that surge protection devices on 24 Vdc cut the fault off before
the 24 Vdc control drops below 21.6 V, disconnecting power to controls and preventing the starting of
emergency and safety functions.
According to EN 60204-1 and EN 61131-1 and -2, surge protection devices on SELV-PELV lines must
be able to disconnect shorts within 10 ms and dangerous surges within 5 s. The use of power supplies
with high output surge capacity and precise and quick protection devices enables to cut faults off before
24 V drops below 21.6 V disconnecting power to controls.
figure 1
Fuses and magneto-thermic switches on 24 Vdc lines do not have l /t features enabling to quickly and
precisely cut faults off; moreover fuses may be replaced with different types thus altering the system’s
protection and safety.
The correct coordination of the circuitry into which the surge protection device is incorporated must take
into account the line’s total R: R connections + R wires + R protection + residual R of the damaged load.
R total value must always enable that the protection device’s tripping current may flow in the circuit; it
is also important to avoid undersizing the protection device in order to prevent inconvenient trips due to
the load’s breakaway starting l, or oversizing it thus increasing t of intervention.
The whole circuitry made up of power supply, surge protection device, wires and connections must be
designed so as to enable the safe interruption of surges within 5 s before 24 Vdc drops below 21.6 Vdc.
This condition may be met using Cabur’s power supplies - series CSF and CSG - dimensioned to supply
high output surge (>+50% of rat.l for >5 s) and electronic surge protection devices with CEP System
which are more precise and quicker than magneto-thermic switches and devices whose tripping t does
not depend upon ambient T and may be reset with local or remote controls.
Features of protection devices
Mgts have two different intervention curves: Thermal and Magnetic. The magnetic relay trips exclusively
in the event of a short with different l/ t curves: thermal relays have all the same intervention curve,
regardless of the mgt curve and in the event of a surge, they operate as described in figure 2: surge
currents 1.13 x In are cut in >1h and with surges > 1.45 X In, the tripping takes place in a few
minutes.
The disconnection of short currents is carried out by a magnetic relay whose tripping t goes from 0.01 to
0.1 sec, with very high currents which the power supply may not be able to supply; an mgt C5 used on
DC has >70 A safe tripping, a current that only power supplies with much higher rated l, i.e. 40 A, may
be able to supply (and not all of them) and that can not be supplied by 10 A power supplies.
Using mgt as surge protection device, if the power supply has a surge l 1.2 times its rat. l, disconnection
will take place in 20…60 min, while with 2.5 currents higher than rat.l it will take place between 25 sec.
and 2 min., depending on amb.T., whose times are too long to ensure the stability of 24 V, for protecting
wires and the selectivity of protection devices. In the event of a failure - until the protection device trips
- the power supply remains with a higher surge of In x 1.5 x 5s and 24 V drops below 21.6 V leaving
standard functions and most of all safety functions with no power supply.
figure 3
Selectivity of protection devices
In the event of a surge or a short, only the damaged circuit is disconnected by its protection device with
no repercussions on the supply of the other loads. This function is obtained with power supplies having
high surge capacity and quick and precise protection devices.
CEP system - a smart system for current’s control
CEP “recognizes” surges at their lowest and more precise stage and disconnects the damaged circuit as
quickly as possible. For an excellent flexible use, the CEP system allows to set 10 tripping currents ranging
from 1A to 10 A in 1 A steps and 3 intervention curves “Fast - Normal - Delayed” (see figure 3).
The protection status is displayed by two leds and by a remote alarm transistor output; the load may
be activated / deactivated by pressing a button on the front (figure 5) or by the PLC remote control.
The possibility of separately controlling single channels is useful during installation, because the various
components may be separately activated and tested and - in big systems - the remote control may be
used in order to gradually activate loads thus preventing simultaneous overloads when the system is
started up. Another important features in terms of safety is the possibility of manually disconnecting the
load, which means that even when protection devices are reset from the remote control, the load will
remain inactive thus preventing dangerous situations.
figure 4
figure 5
65
Programmable electronic
overcurrent protection
1...10 A / 24 Vdc
• Programmable from 1 A to 10 A in 1 A steps
• 3 programmable characteristic curves
• Remote or local ON/OFF control
• Status signal with LED and remote signal
• Slide contact for the manual load disconnection
• Sealable front cover allows to protect the set up of the
protection
115
(4.53 in)
8
(0.32 in)
E258138
NOTES
116
(4.57 in)
BLOCK DIAGRAM
1) sealable front cover
2) current selector
3) identification label
4) characteristic curve
selector
5) ste/reset button
The measures include the overall dimensions and the fixing to
the guide.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) 24 Vdc remote pulse switch the protection at falling edge. The
pulse duration must be: ON = pulse > 1 s / OFF = pulse > 100
ms and < 800 ms
(3) The three standard intervention curves are described in
the grafics; the C EP-D3 Version is also provided with a curve
programmable through a software
VERSIONS
Cod. XCEPD1
CEP-D1
With overload indication
With status indication (ON/OFF/Overload)
With one wire bus
Cod. XCEPD2
Cod. XCEPD3
CEP-D2 (1)
CEP-D3 (1)
INPUT TECHNICAL DATA
Rated voltage
Rated current
Max system current
Protection
Remote control ON/OFF
24 Vdc (range 18…32 Vdc)
10 A dc max.
40 A dc with CEP-RCC copper rail
Internal against reverse polarity
24 Vdc external pulse
CEP-BCR and CEP-BCB
24 Vdc external pulse and by
software (2)
OUTPUT TECHNICAL DATA
Rated voltage
Current min. / max.
Programmable characteristic curves
24 Vdc (voltage drop <170 mV @ Un / In)
1...10 A dc programmable in 10 step of 1 A
slow, medium, fast
slow, medium, fast and a special
programmable custom curve (3)
10.000 μF
green LED: fixed = ok, flashing = lout at 90% of the nominal, red LED: fixed = output manually
switched off, slow flashing = overcurrent, quick flashing = error
open collector transistor
open collector transistor
open collector transistor
(overcurrent status)
(programmable status)
(ON/OFF status)
Switch ON capacity
Status indication
Status display
CEP-MTW
GENERAL TECHNICAL DATA
Operating temperature range
Input/output isolation
Protection degree
Reference Standards
Connection terminal
Housing material
Approx. weight
Mounting information
–25...+60°C, derating Imax. 8 A over 40°C
3 kVac / 60 s SELV output
IP 20 IEC 529, EN60529
EN60950-1, EN61131-1, EN61131-2, EN60898, EN60947-4-1, EN50081
0.25...2.5 mm² fixed screw type
PA 6.6 (UL94V-0, NFF I2, F2)
120 g (4.24 oz)
vertical on rail, adjacent without gap, we recommend the use of end brackets
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Distribution kit (terminal + end bracket)
Distribution rail (busbar)
Insulation cover for distribution rail
Plug-in jumper
Marking tag
red
blue
CEP-SS
CEP-RCC
CEP-RCP
CEP-BCR
CEP-BCB
CEP-MTW
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
(cod. XCEPSS)
(cod. XCEPRCC)
(cod. XCEPRCP)
(cod. XCEPBCR)
(8 poles)
(cod. XCEPBCB)
(8 poles)
(cod. XCEPMTW)
(table with 50 tags)


66
CEP-SS
Intervention curves:
1) fast
2) medium
3) slow
‘
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
3-phase filter without neutral wire 400-480 Vac
Common mode (L / PE) attenuation (dB)
Current
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
Differential mode (L / L) attenuation (dB)
30 MHz
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
30 MHz
Cat. No.
Page
7A
20
60
60
60
50
35
25
60
65
60
55
40
XF07TDVST2
68
16 A
15
50
55
60
50
35
25
55
60
60
55
40
XF16TDVST2
68
30 A
15
50
55
60
50
35
25
55
60
60
55
40
XF30TDVST2
68
42 A
55
70
70
45
35
20
45
45
45
45
45
30
XF42TDVST2
68
55 A
15
55
55
55
50
35
25
55
60
60
50
40
XF55TDVST2
68
75 A
15
55
55
55
50
30
20
50
50
50
55
40
XF75TDVST2
68
100 A
35
50
45
25
15
7
30
35
35
35
30
7
XF100TDVST2
68
150 A
20
30
40
45
40
30
30
40
40
45
40
25
XF150TDS84C
69
180 A
20
30
40
45
40
30
30
40
40
45
40
25
XF180TDS84C
69
200 A
55
60
55
30
20
–
45
30
25
10
10
5
XF200TDDS84C
70
300 A
30
30
23
10
8
5
35
30
25
14
10
5
XF300TDSS84C
71
400 A
30
30
20
10
5
2
30
30
20
10
8
2
XF400TDSS84C
71
Cat. No.
Page
3-phase filter with neutral wire 400-480 Vac
Common mode (L / PE) attenuation (dB)
Current
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
10 A
10
20
20
20
16 A
25
50
50
50
20 A
10
15
20
25 A
25
50
50
36 A
25
50
50 A
25
45
100 A
10
20
Differential mode (L / L) attenuation (dB)
30 MHz
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
30 MHz
30
25
10
20
25
25
30
30
XF10TYG9
73
45
30
35
55
60
60
40
30
XF16TYT2
72
35
40
25
10
15
20
20
25
20
XF20TYS9
73
50
45
30
35
55
60
60
40
30
XF25TYT2
72
50
50
40
25
30
50
55
50
40
30
XF36TYT2
72
45
40
40
25
30
50
50
40
40
30
XF50TYT2
72
25
30
30
20
30
40
40
35
35
25
XF100TYT2
72
Cat. No.
Page
Single-cell single-phase filter 120-250 Vac
Common mode (L / PE) attenuation (dB)
Current
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
3A
20
30
35
45
Differential mode (L / L) attenuation (dB)
30 MHz
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
30 MHz
50
45
7
35
50
45
45
45
XF03DKBG5B
74
6A
15
20
25
40
45
45
10
20
45
45
50
45
XF06DKBG5B
74
12 A
10
20
22
35
45
40
10
20
40
45
45
45
XF12DKBG5B
74
16 A
10
18
20
35
45
30
10
18
40
40
40
35
XF16DKCG5B
74
20 A
10
18
20
30
35
35
10
12
35
35
40
40
XF20DKCG5B
74
30 A
10
25
30
45
50
35
12
40
50
50
50
45
XF30DKCS5B
74
Cat. No.
Page
Double-cell single-phase filter 120-250 Vac
Common mode (L / PE) attenuation (dB)
Current
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
3A
45
60
60
55
Differential mode (L / L) attenuation (dB)
30 MHz
0.15
MHz
0.5
MHz
1
MHz
5
MHz
10 MHz
30 MHz
45
45
12
45
45
45
45
45
XF03DPCG5C
75
6A
30
50
60
55
50
35
8
45
45
45
45
45
XF06DPCG5C
75
12 A
15
25
35
55
55
35
12
40
40
35
35
40
XF12DPCG5C
75
16 A
20
35
45
60
50
35
12
40
40
45
45
50
XF16DPCG5C
75
20 A
15
40
45
50
50
40
12
45
45
45
35
50
XF20DPCG5C
75
30 A
10
30
35
55
45
30
18
45
50
40
40
40
XF30DPGS5C
75
67
3-phase filter without
neutral TDV series
C
• Models from 7 to 130 A
• High attenuation from 50 kHz to 30 MHz
• High attenuation also with long cables
• Minimum space on the panel
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) According to EN60950 insulation tests on input side must be
made only with DC instruments.
(2) Version available upon request; for information call our sales
department, local agent or representative
L1
L1’
L
L2
L2’
LINE
L3
L3’
Cx1
VERSIONS
Type
F 07 TDV ST2
F 16 TDV ST2
F 30 TDV ST2
F 42 TDV ST2
F 55 TDV ST2
F 75 TDV ST2
F 100 TDV ST2
Cat. No.
XF07TDVST2
XF16TDVST2
XF30TDVST2
XF42TDVST2
XF55TDVST2
XF75TDVST2
XF100TDVST2
(2)
(2)
(2)
(2)
(2)
(2)
(2)
Cy
Dimensions
B
192 (7,56 in)
252 (9,93 in)
272 (10,72 in)
312 (12,29 in)
252 (9,93 in)
272 (10,72 in)
270 (10,64 in)
A
42 (1,65 in)
47 (1,85 in)
52 (2,05 in)
52 (2,05 in)
87 (3,43 in)
92 (3,62 in)
90 (3,55 in)
R1
Cx2
PE
Rated current
7A
16 A
30 A
42 A
55 A
75 A
100 A
LOAD
L
PE
R2
Weight
(kg)
C
72 (2,84 in)
72 (2,84 in)
87 (3,43 in)
87 (3,43 in)
92 (3,62 in)
137 (5,4 in)
150 (5,91 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation L/L
Insulation L/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
480 Vac ± 10%
see versions table
50…60 Hz
30 mA
–25...+85°C
1.45 KVdc / 60 s
2.25 KVdc / 60 s
—
IP 20 IEC 529, EN60529
screw terminals
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F 07 TDV ST2
F 16 TDV ST2
F 30 TDV ST2
F 42 TDV ST2
F 55 TDV ST2
F 75 TDV ST2
F 100 TDV ST2
0.15
MHz
20
15
15
55
15
15
35
0.5
MHz
60
50
50
70
55
55
50
1
MHz
60
55
55
70
55
55
45
5
MHz
60
60
60
45
55
55
25
(1)
(1)
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
50
50
50
35
50
50
15
35
35
35
20
35
30
7
0.15
MHz
25
25
25
45
25
20
30
68
0.5
MHz
60
55
55
45
55
50
35
1
MHz
65
60
60
45
60
50
35
5
MHz
60
60
60
45
60
50
35
10 MHz
30 MHz
55
55
55
45
50
55
30
40
40
40
30
40
40
7
3-phase filter without
neutral TDS series
• Models from 150 to 180 A
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
C
PRELIMINARY
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) According to EN60950 insulation tests on input side must be
made only with DC instruments.
L1
L1’
L2
L2’
LINE
LOAD
L3
L3’
PE
PE
VERSIONS
Rated current
150 A
180 A
Type
F 150 TDS 84C
F 180 TDS 84C
Cat. No.
XF150TDS84C (1)
XF180TDS84C (1)
Dimensions
B
390 (15,37 in)
390 (15,37 in)
A
202 (7,96 in)
202 (7,96 in)
Weight
(kg)
C
122 (4,81 in)
122 (4,81 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
480 Vac ± 10%
see versions table
50…60 Hz
500 mA
–25...+85°C
1 KVdc / 60 s (2)
1 KVdc / 60 s (150A) – 2.25 KVdc / 60 s (180A) (2)
—
IP 20 IEC 529, EN60529
with screw bolts
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F 150 TDS 84C
F 180 TDS 84C
0.15
MHz
20
20
0.5
MHz
30
30
1
MHz
40
40
5
MHz
45
45
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
40
40
30
30
0.15
MHz
30
30
69
0.5
MHz
40
40
1
MHz
40
40
5
MHz
45
45
10 MHz
30 MHz
40
40
25
25
3-phase filter without
neutral serie TDDS
C
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) According to EN60950 insulation tests on input side must be
made only with DC instruments.
L1
L1’
L2
L2’
LINE
LOAD
L3
L3’
PE
PE
VERSIONS
Rated current
200 A
Type
Cat. No.
F 200 TDDS 84C XF200TDDS84C (1)
Dimensions
B
477 (18,79 in)
A
240 (9,46 in)
Weight
(kg)
C
140 (5,52 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
480 Vac ± 10%
200 A
50…60 Hz
500 mA
–25...+85°C
1 KVdc / 60 s
(2)
1.8 KVdc / 60 s
(2)
—
IP 20 IEC 529, EN60529
with screw bolts
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F 200 TDDS 84C
0.15
MHz
55
0.5
MHz
60
1
MHz
55
5
MHz
30
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
20
/
0.15
MHz
45
70
0.5
MHz
30
1
MHz
25
5
MHz
10
10 MHz
30 MHz
10
5
3-phase filter without
neutral TDSS series
• Models from 300 to 600 A
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
C
PRELIMINARY
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) Version available upon request; for information call our sales
department, local agent or representative
(2) According to EN60950 insulation tests on input side must be
made only with DC instruments.
L1
L1’
L2
LINE
L2’
LOAD
L3
L3’
VERSIONS
Rated current
300 A
400 A
Type
Cat. No.
F 300 TDSS 84C XF300TDSS84C (1)
F 400 TDSS 84C XF400TDSS84C (1)
Dimensions
B
525 (20,69 in)
525 (20,69 in)
A
242 (9,53 in)
242 (9,53 in)
Weight
(kg)
C
142 (5,59 in)
142 (5,59 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
480 Vac ± 10%
see versions table
50…60 Hz
1000 mA
–25...+85°C
0.6 KVdc / 60 s
(2)
1 KVdc / 60 s
(2)
—
IP 20 IEC 529, EN60529
with flat plug
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F 300 TDSS 84C
F 400 TDSS 84C
0.15
MHz
30
25
0.5
MHz
40
35
1
MHz
40
30
5
MHz
25
20
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
20
20
15
10
0.15
MHz
40
40
71
0.5
MHz
40
35
1
MHz
50
35
5
MHz
35
20
10 MHz
30 MHz
30
15
20
10
3-phase filter with neutral
serie TYT
• Models from 16 to 100 A
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
C
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) According to EN60950 insulation tests on input side must be
made only with DC instruments.
(2) Version available upon request; for information call our sales
department, local agent or representative
L1'
L1
L
L2
L2'
LINE
LOAD
L
L3'
L3
Cx
R
L
C x1
N
L4'
Cy
Cy
PE
PE
VERSIONS
Rated current
16 A
25 A
36 A
50 A
100 A
Type
F 16 TYT2
F 25 TYT2
F 36 TYT2
F 50 TYT2
F 100 TYT2
Cat. No.
XF16TYT2
XF25TYT2
XF36TYT2
XF50TYT2
XF100TYT2
(2)
(2)
(2)
(2)
(2)
Dimensions
B
191,5 (7,55 in)
191,5 (7,55 in)
191,5 (7,55 in)
194 (7,64 in)
252 (9,93 in)
A
107 (4,22 in)
107 (4,22 in)
107 (4,22 in)
124 (4,89 in)
162 (6,38 in)
Weight
(kg)
C
82 (3,23 in)
82 (3,23 in)
82 (3,23 in)
104 (4,1 in)
132 (5,2 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
440 Vac ± 10%
see versions table
50...60Hz
3 mA
–25...+85°C
1.45 KVdc / 60 s
2.25 KVdc / 60 s
—
IP 20 IEC 529, EN60529
screw terminals
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F 16 TYT2
F 25 TYT2
F 36 TYT2
F 50 TYT2
F 100 TYT2
0.15
MHz
25
25
25
25
10
0.5
MHz
50
50
50
45
20
1
MHz
50
50
50
45
25
5
MHz
50
50
50
40
30
(1)
(1)
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
45
45
40
40
30
30
30
25
25
20
0.15
MHz
35
35
30
30
30
72
0.5
MHz
55
55
50
50
40
1
MHz
60
60
55
50
40
5
MHz
60
60
50
40
35
10 MHz
30 MHz
40
40
40
40
35
30
30
30
30
25
Compact 3-phase filter with
neutral TY series
• Models from 10 to 20 A
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
• Eccellent quality/price/performances ratio
C
B
A
NOTES
BLOCK DIAGRAM
L1
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) According to EN60950 insulation tests on input side must be
made only with DC instruments.
(2) Version available upon request; for information call our sales
department, local agent or representative
L1’
L
L2’
L2
LINE
LOAD
L
L3
L3’
Cx
Cx
Cx
L
N
N
Cy
PE
VERSIONS
Rated current
10 A
20 A
Type
F 10 TYG9
F 20 TYS9
Cat. No.
XF10TYG9 (2)
XF20TYS9 (2)
Dimensions
B
85 (3,35 in)
97 (3,82 in)
A
50 (1,97 in)
50 (1,97 in)
Weight
(kg)
C
44 (1,73 in)
44 (1,73 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
440 Vac ± 10%
see versions table
50...60Hz
0.5 mA
–25...+85°C
1.45 KVdc / 60 s
(1)
2.25 KVdc / 60 s
(1)
—
IP 20 IEC 529, EN60529
with flat plug (10 A) and with screw terminals (20 A)
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F 10T YG9
F 20 TYS9
0.15
MHz
10
10
0.5
MHz
20
15
1
MHz
20
20
5
MHz
20
20
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
30
25
25
20
0.15
MHz
10
10
73
0.5
MHz
20
15
1
MHz
25
20
5
MHz
25
20
10 MHz
30 MHz
30
25
30
20
Single-cell single-phase
filter DK series
• Models from 3 to 30 A
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
• Minimum space on the panel
C
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) 0.25 mA @ 115 Vac e 0.45 mA @ 250 Vac for models from
3…20 A - 1 mA @ 115 Vac e 2 mA @ 250 Vac for the
model of 30 A.
(2) Version available upon request; for information call our sales
department, local agent or representative.
(3) With flat plug for models from 3…20 A – with screw bolt for
the model from 30 A.
(4) According to EN60950 insulation tests on input side must be
made only with DC instruments.
L
LINE
Type
F 03 DK BG5B
F 06 DK BG5B
F 12 DK BG5B
F 16 DK CG5B
F 20 DK CG5B
F 30 DK CS5B
Cat. No.
XF03DKBG5B
XF06DKBG5B
XF12DKBG5B
XF16DKCG5B
XF20DKCG5B
XF30DKCS5B
(2)
(2)
(2)
(2)
(2)
(2)
L'
Cx
L
Cx
Cy
LOAD
Cy
N
N'
PE
VERSIONS
Rated current
3A
6A
12 A
16 A
20 A
30 A
R
Dimensions
B
34 (1,34 in)
34 (1,34 in)
34 (1,34 in)
71,5 (2,82 in)
84,8 (3,34 in)
114 (4,49 in)
A
64,5 (2,54 in)
64,5 (2,54 in)
64,5 (2,54 in)
45,5 (1,79 in)
51,8 (2,04 in)
56,5 (2,23 in)
Weight
(kg)
C
30 (1,18 in)
30 (1,18 in)
30 (1,18 in)
30 (1,18 in)
30 (1,18 in)
46,4 (1,83 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
115–250 Vac ± 10%
see versions table
50…60 Hz
0.25…1 mA / 0.45…2 mA
(1)
–25...+85°C
1.45 KVdc / 60 s
(4)
2.25 KVdc / 60 s
(4)
—
IP 20 IEC 529, EN60529
with flat plug (from 3 to 20 A) / with screw bolt (30 A) (3)
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F
F
F
F
F
F
03
06
12
16
20
30
DK
DK
DK
DK
DK
DK
BG5B
BG5B
BG5B
CG5B
CG5B
CS5B
0.15
MHz
20
15
10
10
10
10
0.5
MHz
30
20
20
18
18
25
1
MHz
35
25
22
20
20
30
5
MHz
45
40
35
35
30
45
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
50
45
45
45
35
50
45
45
40
30
35
35
0.15
MHz
7
10
10
10
10
12
74
0.5
MHz
35
20
20
18
12
40
1
MHz
50
45
40
40
35
50
5
MHz
45
45
45
40
35
50
10 MHz
30 MHz
45
50
45
40
40
50
45
45
45
35
40
45
Double-cell single-phase
filter DP series
• Models from 3 to 30 A
• High attenuation from 150 kHz to 30 MHz
• High attenuation also with long cables
• Minimum space on the panel
C
B
A
NOTES
BLOCK DIAGRAM
Dimensions and diagrams are indicative, for more details see
the products data sheet.
(1) 0.25 mA @ 115 Vac e 0.45 mA @ 250 Vac for models from
3…20 A - 1 mA @ 115 Vac e 2 mA @ 250 Vac for the
model of 30 A.
(2) Version available upon request; for information call our sales
department, local agent or representative.
(3) With flat plug for models from 3…20 A – with screw bolt for
the model from 30 A.
(4) According to EN60950 insulation tests on input side must be
made only with DC instruments.
L
LINE
Type
F 03 DP CG5C
F 06 DP CG5C
F 12 DP CG5C
F 16 DP CG5C
F 20 DP CG5C
F 30 DP GS5C
Cat. No.
XF03DPCG5C
XF06DPCG5C
XF12DPCG5C
XF16DPCG5C
XF20DPCG5C
XF30DPGS5C
(2)
(2)
(2)
(2)
(2)
(2)
C2
L1
R
C3
L2
C3
N
PE
Dimensions
B
75 (2,96 in)
143 (5,63 in)
75 (2,96 in)
A
84,8 (3,34 in)
152,9 (6,02 in)
84,8 (3,34 in)
LOAD
N'
PE
VERSIONS
Rated current
3A
6A
12 A
16 A
20 A
30 A
L'
C1
Weight
(kg)
C
52 (2,05 in)
51,3 (2,02 in)
52 (2,05 in)
56,5 (2,23 in)
46.4 (1,83 in)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Frequency
Leakage current at 480 Vac 60 Hz
Operating temperature range
Insulation line/line
Insulation line/PE
Overvoltage category/Pollution degree
Protection degree
Connection terminal
Housing material
Approx. weight
Mounting information
115–250 Vac ± 10%
see versions table
50…60 Hz
0.25…1 mA / 0.45…2 mA
(1)
–25...+85°C
1.45 KVdc / 60 s
(4)
2.25 KVdc / 60 s
(4)
—
IP 20 IEC 529, EN60529
with flat plug (from 3 to 20 A) / with screw bolt (30 A) (3)
metal
see versions table
on the panel with screws
Common mode (L / PE) attenuation (dB)
Type
F
F
F
F
F
F
03
06
12
16
20
30
DP
DP
DP
DP
DP
DP
CG5C
CG5C
CG5C
CG5C
CG5C
GS5C
0.15
MHz
45
30
15
20
15
10
0.5
MHz
60
50
25
35
40
30
1
MHz
60
60
35
45
45
35
5
MHz
55
55
55
60
50
55
Differential mode (L / L) attenuation (dB)
10 MHz
30 MHz
45
50
55
50
50
45
45
35
35
35
40
30
0.15
MHz
12
8
12
12
12
18
75
0.5
MHz
45
45
40
40
45
45
1
MHz
45
45
40
40
45
50
5
MHz
45
45
35
45
40
40
10 MHz
30 MHz
45
45
35
45
35
40
45
45
40
50
50
40
Applications of analogue signal converters
and galvanic isolation
T
hese convert electric signals generated by sensors for measuring physical quantities such
as: temperature (RTD thermocouples and PT100 thermal resistors), frequency (proximity,
contacts, photoelectric cells), current (HV, Hall sensors), resistance (potentiometers), voltage,
pressure, level etc., into standardised electrical signals, adapting them to the I/O of industrial
PLC’s, DCS’s, and PC’s (control), or they convert a given analogue signal into a different one,
adapting it to the inputs/outputs of the control, or allow remote transmission of the signal without interference via galvanic isolation (Fig. 1).
ADAPTATION OF THE SIGNAL
fig. 1
Adaptation between sensor output signal and control input signal
physical quantity measured
sensor output
converter input
converter output
Temperature
0 – 60 mV
±60 mV
0–5V
±5 V
Frequency
0 – 100 mV
±100 mV
0 – 10 V
±10 V
Current
0 – 500 mV
±500 mV
0 – 20 mA
±20 mA
Resistance
0–1V
±1 V
4 – 20 mA
0–5V
±5 V
0 – 10 V
±10 V
0 – 5 mA
±5 mA
0 – 10 mA
±10 mA
0 – 20 mA
±20 mA
Voltage
Pressure
Normally one of the signals
indicated in the next column
Level measurement
0 – 20 mA
Remote transmission of the signal
The voltage signals reach a max. distance of 10-20 m, beyond this they lose reliability and
become very sensitive to earth and induced interference for this reason, in order to transmit
at a distance more than 20 m, a voltage signal must be converted into a current signal and
galvanically isolated.(Fig. 2).
Current signals exceed 300 m of transmission distance and are less sensitive to induced interference. In order to transmit a current signal at a distance galvanic isolation is required.
sensor
control
 Input amplifier
 Opto-isolator
‘ Signal adapter
’ Output amplifier
main
“ DC/DC converter
BLOCK DIAGRAM OF AN AMPLIFIER WITH GALVANIC ISOLATION
fig. 2
76
Galvanic isolation of the signal:
• electrically isolates and separates the circuit of the sensor from the
control and power supply circuits. Thus each circuit operates with
reference to its own zero potential which, being isolated from other
circuits, cannot be altered by differences in potential always present
between different earth references (Figs. 3).
NON-ISOLATED THERMOCOUPLE AND DIFFERENT ZERO POTENTIALS
fig. 3
• isolates and separates the various zero potentials between power supply,
control and sensors/actuators;
• allows transmission of the signal without errors or interference and with
greater reliability;
• the higher the isolation (in kV), the greater the security of transmission
where there are zero potentials, electromagnetic interference, transients
(lightning, discharges etc.) (Fig. 4).
Measurement error
POTENTIAL DIFFERENCE AND EARTH CIRCUITS
fig. 4
Galvanic isolation is necessary when:
• the distance between control and sensor/actuator is more than 20 m;
• the earth references are different;
• the zero potentials are high, or potentially high in the case of discharges
or earth dispersed currents;
• electromagnetic interference is present;
• the signal cables are wired in conduits with power cables (Fig. 5).
INTERFERENCE
fig. 5
Series and parallel connection of the analogue converters
• To achieve redundancy of a signal or just to duplicate it, you can connect
the input of more analogue converters to a single sensor.
• In case of current signals, the input of the converters must be connected
in series (Fig. 6).
+IN
+
Pwr
+
–
U, I
+
–
Pwr
+
–
U, I
+
–
U,I I
–IN
–
+
U,I I
–
+24V
GND
+OUT1
–OUT1
+OUT2
–OUT2
SERIAL CONVERTERS
fig. 6
• In case of voltage signals, the input of the converters must be connected
in parallel (Fig. 7).
+IN
+
Pwr
+
–
U, I
+
–
Pwr
+
–
U, I
+
–
UI
U,
–IN
–
+
UI
U,
–
+24V
GND
+OUT1
–OUT1
+OUT2
–OUT2
PARALLEL CONVERTERS
fig. 7
77
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Analogue signal converters and galvanic isolators
Output
Isolation
Power supply
Notes
Type
Cat. No.
Page
0...60 / 0...100 / 0...500 mV
±60 / ±100 / ±500 mV
0...1 / 0...2 / 0...5 / 0...10 V
±1 / ±2 / ±5 / ±10 V
0...5 / 0...10 / 0...20 / 4...20 mA
±5 / ±10 / ±20 mA
Input
0...5 / 0...10 / ±5 / ±10 V
0...20 / 4...20 / ±20 mA
3 ways
24 Vdc
(1) (4)
CA-PI/PO1
XSSAPIPO1
81
0...60 / 0...100 / 0...300 / 0...500 mV
0...1 / 0...10 / 0...20 / 2...20 V
0...5 / 0...10 / 0...20 / 4...20 / ±5 / ±20 mA
0...10 V
0...20 / 4...20 mA
3 ways
24 Vac/dc
(1) (4)
CWUAA 6-0516
X756516
82
0...60 / 0...100 / 0...300 / 0...500 mV
0...1 / 0...10 / 0...20 / 2...20 V
0...5 / 0...10 / 0...20 / 4...20 / ±5 / ±20 mA
0...10 V
0...20 / 4...20 mA
3 ways
24...240 Vac/dc
(1) (5)
CWUAA 6-0517
X756517
82
0...10 V
0...20 / 4...20 mA
0...10 V
0...20 / 4...20 mA
3 ways
24 Vac/dc
(1) (4)
CWNAA 7-0539
X756539
83
0...10 V
0...20 / 4...20 mA
0...10 V
0...20 / 4...20 mA
3 ways
24...240 Vac/dc
(1) (5)
CWNAA 6-0510
X756510
83
0...10 V
0...10 V
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0530
X756530
84
0...10 V
0...20 mA
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0531
X756531
84
0...10 V
4...20 mA
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0532
X756532
84
0...20 mA
0...10 V
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0533
X756533
85
0...20 mA
0...20 mA
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0534
X756534
85
0...20 mA
4...20 mA
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0535
X756535
85
4...20 mA
0...10 V
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0536
X756536
86
4...20 mA
0...20 mA
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0537
X756537
86
4...20 mA
4...20 mA
3 ways
24 Vac/dc
(2) (4)
CWAA 6-0538
X756538
86
0...20 / 4...20 mA
0...20 / 4...20 mA
2 ways
—
(4)
CWPAA 7-0526
X756526
87
0...20 / 4...20 mA
0...20 / 4...20 mA
2 ways
—
(3) (4)
CWPAA 7-0527
X756527
87
-30...+30 V / -50...+50 mA / -5...+5 A
0...20 / 4...20 mA
3 ways
24 Vdc
(6) (7)
LCONALSFDT
X756360
88
(4) 1.5 kVac / 60 s two way isolation (input / output) or 1.5 kVac / 60 s three way isolation
(input / output / supply)
(5) 4 kVac / 60 s three way isolation (input / output / supply)
(6) Input and Output signal range programmable via dip-switch and software
(7) 2.5 kVac / 60 three way isolation (input / output / supply)
Notes
(1) programmable input and output signal via DIP switches
(2) single range input and output signal (not programmable), articles generally not in stock but
available upon request, for info please contact our sales department
(3) two channels version
78
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Current tranducers and limit value switch
Isolation
Power supply
Notes
Type
Cat. No.
Page
0…50 A ac
Input
adjustable threshold 1…30 A
Output
2 ways
24 Vdc
(3) (4)
CCIS-2
XCCIS2
93
0…1 A ac/dc
0...10 V
0...20 / 4...20 mA
2 ways
24 Vdc
(2)
WAA 7-0540
X756540
94
0…5 A ac/dc
0...10 V
0...20 / 4...20 mA
2 ways
24 Vdc
(2)
WAA 7-0541
X756541
94
0…10 A ac/dc
0...10 V
0...20 / 4...20 mA
2 ways
24 Vdc
(2)
WAA 7-0542
X756542
94
Notes
(1) single I/O version
(2) three programmable output signals
(3) open collector threshold output
(4) threshold output with one changeover relay
Frequency signal converter
Input
0…28.8 kHz (21 ranges)
Output
0...10 V
0...20 / 4...20 mA
Isolation
Power supply
Notes
Type
Cat. No.
Page
2 ways
24 Vac/dc
(1)
CWNFA 6-0524
X756524
97
Type
Cat. No.
Page
CWCV 7-6184
X766184
98
Auxiliary power supply for sensors and potentiometers
Input
24 Vdc
Output
10 Vdc
Isolation
Power supply
Notes
2 Vie
NPN and PNP signal polarity inverter
Type
Cat. No.
Page
NPN (17…30 Vdc)
Input
PNP
Output
Isolation
CI-NPN/PNP
XNPNPNP
99
PNP (17…30 Vdc)
NPN
CI-NPN/PNP
XNPNPNP
99
79
Power supply
Notes
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Temperature transducers
Sensor Type
Input
Output
Isolation
Power supply
Notes
Type
Cat. No.
Page
PT100 e PT1000
(2, 3, 4 wires), Thermocouples B, C, E, J, K, N, R, S, T,
Potentiometers 0-600 kOhm
Programmable
-200...+2400°C (-328...+4352°F)
according to sensor type
0...10 V / -10...+10 V
0...20 mA / 4...+20 mA
3 ways
24 Vdc
(1) (2)
LCONTADFDT
X756340
89
PT100 e PT1000
(2, 3, 4 wires), Thermocouples B, C, E, J, K, N, R, S, T,
Potentiometers 0-600 kOhm
Programmable
-200...+2400°C (-328...+4352°F)
according to sensor type
2 thresholds
(NO contacts)
3 ways
24 Vdc
(2)
LCONTLSFDT
X756370
90
PT100 3 wire
(RTD)
-50…+50°C (-58…+122°F)
-50…+100°C (-58…+212°F)
-50…+150°C (-58…+302°F)
0…+100°C (+32…+212°F)
0…+150°C (+32…+302°F)
0…+200°C (+32…+392°F)
0…+300°C (+32…+572°F)
0…+400°C (+32…+752°F)
0...10 V
0...20 / 4...20 mA
3 ways
24 Vac/dc
(2)
CWPT 6-0816
X756816
91
PT100 3 wire
(RTD)
-50…+50°C (-58…+122°F)
-50…+100°C (-58…+212°F)
-50…+150°C (-58…+302°F)
0…+100°C (+32…+212°F)
0…+150°C (+32…+302°F)
0…+200°C (+32…+392°F)
0…+300°C (+32…+572°F)
0…+400°C (+32…+752°F)
0...10 V
0...20 / 4...20 mA
3 ways
24...240 Vac/dc
(2)
CWPT 6-0817
X756817
91
Thermocouples
J (FeCuNi) and
K (NiCrNi)
-50…+200°C (-58…+392°F)
-50…+350°C (-58 …+662°F)
0…+200°C (+32…+392°F)
0…+400°C (+32…+752°F)
0…+600°C (+32…+1112°F)
0…+800°C (+32…+1472°F)
0…+1000°C (+32…+1832°F)
0…+1200°C (+32…+2192°F)
0...10 V
0...20 / 4...20 mA
3 ways
24 Vac/dc
(2)
CWTH 6-0844
X756844
92
Thermocouples
J (FeCuNi) and
K (NiCrNi)
-50…+200°C (-58…+392°F)
-50…+350°C (-58 …+662°F)
0…+200°C (+32…+392°F)
0…+400°C (+32…+752°F)
0…+600°C (+32…+1112°F)
0…+800°C (+32…+1472°F)
0…+1000°C (+32…+1832°F)
0…+1200°C (+32…+2192°F)
0...10 V
0...20 / 4...20 mA
3 ways
24...240 Vac/dc
(2)
CWTH 6-0847
X756847
92
Notes
(1) programmable input and output signals via software
(2) programmable input and output signals via dip-switch
80
Programmable analogue
signal converter
• 19 input scales
• 7 output scales
• 1 SPST (NO) alarm contact
• IN/OUT isolation >3 kVac
• Auxiliary supply output for loop-powered sensors
• Input for potentiometer
NOTES
108
(4.26 in)
22.5
(0.89 in)
119
(4.69 in)
BLOCK DIAGRAM
The dimensions includes the terminal blocks and
the DIN clamp.
(1) The modules in stock are programmed and
calibrated with with 0...10 V and 0...10 V output.
Modules programmed and calibrated for all
other possible configurations can be supplied on
request.
VERSIONS
Cat. No. XCAPIPO3
CAPIPO3
INPUT TECHNICAL DATA
Input signal (1)
Impedance voltage / current mode
Max. input voltage
Max. input current
19 programmable ranges (see Table 1)
1 MΩ / 50 Ω
15 V
30 mA
OUTPUT TECHNICAL DATA
Output signal (1)
Applicable load (voltage / current model)
Max. output voltage
Max. output current
7 programmable ranges (see Table 2)
≥ 10 kΩ / ≤ 500 Ω
12 V
25 mA
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Auxiliary DC feed output max. current
Gain error
Offset error
Linearity error
Zero adjustment / Span adjustment
Transmission frequency
Rise time
Bandwidth
Phase delay
I/O / supply isolation
Continuous voltage isolation
Reference Standard
Overvoltage category/Pollution degree
Operating temperature range
ΔT
Protection degree
ECM standards
Connection terminal
Housing material
Approx. weight
Mounting information
15...36 Vdc
100 mA max. @ 24 Vdc
10 Vdc 5 mA / 24 Vdc 30 mA
< 0.1% FS
< 0.05 % FS
< 0.1% FS
± 10% FS
400Hz...1kHz according to full-scale
150 mV / μs
1 kHz @ -6 dB
< 10 μs
> 3 kVac / 60 s
800 Vac max.
IEC 664-1, DIN VDE0110.1
III / 2
-10... +65°C
5°C
IP 20 IEC 529, EN60529
EN 50081-2 , EN 50082-2
2.5 mm2 pluggable screw type (14 AWG)
polyamide UL94V-0
150 g (5.29 oz)
vertical on rail, allow 5 mm spacing between adjacent component
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
81
INPUT STAGE
The module can manage single-pole and two-pole inputs,
choosing from among the ranges (see Table 1):
• 0…60 mV
± 60 mV
• 0…100 mV
± 100 mV
• 0…500 mV
± 500 mV
• 0…1 V
±1V
• 0…5 V
±5V
• 0…10 V
± 10 V
• 0…5 mA
± 5 mA
• 0…10 mA
± 10 mA
• 0…20 mA
± 20 mA
• 4…20 mA
The input stage provides two auxiliary supply outputs, for
feeding loop powered sensor and potentiometer directly
from the module (10V e 24V).
Example of connection:
2-wire
sensor
3-wire
sensor
potentiometer
≥ 1 kΩ
OUTPUT STAGE
The module supplies in output single-pole and two-pole
signals with the following ranges (see Table 2):
• 0…5 V
±5V
• 0…10 V
± 10 V
• 0…20 mA
± 20 mA
• 4…20 mA
Programmable analogue
signal converters
79
(3.11 in)
• 3 ways galvanic isolation
• 14 programmable input range
• 3 programmable output range
• Simple programming
• Available version with 24-240 Vac/dc supply voltage
17.5
(0.69 in)
84
(3.31 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) Adjustable via rotary-switch
(2) Adjustable via dip-switch
(3) range 16.8…30 Vdc / 19.2…28.8 Vac
(4) range 16.8…264 Vdc / 19.2…264 Vac
(5) 3-way isolation: IN/OUT/power supply
(6) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
24 Vac/dc supply voltage
24-240 Vac/dc supply voltage
Power supply
24 Vac/dc
Power supply
24...240 Vac/dc
Cat. No. X756516
CWUAA 6-0516
Cat. No. X756517
CWUAA 6-0517 (6)
INPUT TECHNICAL DATA
Input signal (1)
Input resistance
0...60 / 0...100 / 0...300 / 0…500 mV
0…1 / 0…10 / 0…20 / 2…20 V
0…5 / 0…10 / 0…20 / 4…20 / ±5 / ±20 mA
330 kΩ with input voltage
100 Ω with input current
0...60 / 0...100 / 0...300 / 0…500 mV
0…1 / 0…10 / 0…20 / 2…20 V
0…5 / 0…10 / 0…20 / 4…20 / ±5 / ±20 mA
330 kΩ with input voltage
100 Ω with input current
0…10 V
0…20 / 4…20 mA
>1 kΩ with output voltage
<400 Ω with output current
0…10 V
0…20 / 4…20 mA
>1 kΩ with output voltage
<400 Ω with output current
24 Vac/dc (3)
≤ 35 mA ± 10% @ 24 Vdc
0.1% @ 23°C FS
< 30 Hz
0.02% / K FS
1.5 kVac / 60 s (5)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
,,,
IP 20 IEC 529, EN60529
-25…+60°C
2.5 mm² fixed screw type
Noryl UL94V-0
65 g (2.29 oz)
vertical on rail adjacent without gap
24-240 Vac/dc (4)
≤ 35 mA ± 10% @ 24 Vdc
0.1% @ 23°C FS
< 30 Hz
0.02% / K FS
4 kVac / 60 s (5)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
,,,
IP 20 IEC 529, EN60529
-25…+60°C
2.5 mm² fixed screw type
Noryl UL94V-0
75 g (2.65 oz)
vertical on rail adjacent without gap
OUTPUT TECHNICAL DATA
Output signal (2)
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
82
APPLICATIONS
Multifunction converters can be
used to convert and isolate the
most common standard analogue
signals; the input of the modules
can be set up into 14 signal ranges
and the output can be set for up to
3 most important analogue ranges.
The set up is possible by simply switching the position of a dip
switch on the side of the module.
The many different input / output
combinations offered by multifunctions modules allows to reduce
inventory for both new and replacement products and provides many
signal conversion solutions.
The “3 ways” galvanic isolation
assures total isolation between
input, output and supply input;
this feature, and the “self calibrating signal circuitry”, gives excellent accuracy without any manual
adjustment.
If a single signal must provide several output channels it is possible to
use many modules connecting their
inputs in parallel as long as the
signal is voltage, or in series when
signal is current.
Programmable analogue
signal converters
90
(3.55 in)
• 1.5 kV, 3 ways, IN/OUT/supply voltage isolation
• 3 programmable input range
• 3 programmable output range
• Simple programming and self calibrating
6.2
(0.24 in)
92.5
(3.64 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) range 16.8…264 Vdc / 19.2…264 Vac
(3) 3-way isolation: IN/OUT/power supply
Power supply
24 Vac/dc
VERSIONS
Cod. X756539
CWNAA-7-0539
24 Vac/dc supply voltage
24-240 Vac/dc supply voltage
—
—
INPUT TECHNICAL DATA
Input signal
0…10 V
0…20 / 4…20 mA
330 kΩ with input voltage
100 Ω with input current
Input resistance
OUTPUT TECHNICAL DATA
Output signal
0…10 V
0…20 / 4…20 mA
>1 kΩ with output voltage
<400 Ω with output current
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vac/dc (1)
≤ 35 mA ± 10% @ 24 Vdc
0.1% @ 23°C FS
< 30 Hz
0.02% / K FS
1.5 kVac / 60 s (3)
EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
,,,
IP 20 IEC 529, EN60529
-25…+60°C
2.5 mm² fixed screw type
Noryl UL94V-0
40 g
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 cod. X766802
—
CWBK 7-0803 cod. X766803
—
CWBK 7-0804 cod. X766804
—
83
APPLICATIONS
Multi-function converters can be
used to convert and isolate the
most common standard analogue
signals; the input and the output
can be set up into 3 different signal
ranges. The set up is possible by
simply switching the position of
a dip switch on the side of the
module.
The input / output combinations
offered by these modules provide
the most common input/output
configurations more economically
when compared to 14 input / 3
output modules and reduces
inventory.
If a single signal must provide
several output channels it is
possible to use many modules
connecting their inputs in parallel
as long as the signal is voltage, or in
series when signal is current.
Analogue signal converters
• 1.5 kV, 3 ways, IN/OUT/supply voltage isolation
• Fixed value
• Compact dimension, 6.2 mm pitch
90
(3.55 in)
6.2
(0.24 in)
92.5
(3.64 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way isolation: IN/OUT/power supply
Power supply
24 Vac/dc
VERSIONS
Cat. No. X756530
CWAA 7-0530
IN: 0...10 V / OUT: 0...10 V
IN: 0...10 V / OUT: 0...20 mA
IN: 0...10 V / OUT: 4...20 mA
Cat. No. X756531
Cat. No. X756532
CWAA 7-0531
CWAA 7-0532
INPUT TECHNICAL DATA
Input signal
Input resistance
0…10 V
330 kΩ
0…10 V
330 kΩ
0…10 V
330 kΩ
0...10 V
>1 kΩ
0...20 mA
<400 Ω
4...20 mA
<400 Ω
OUTPUT TECHNICAL DATA
Output signal
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vac/dc (1)
24 Vac/dc (1)
24 Vac/dc (1)
≤ 13 mA ± 10%
≤ 13 mA ± 10%
≤ 13 mA ± 10%
0.1% @ 23°C FS
0.1% @ 23°C FS
0.1% @ 23°C FS
< 30 Hz
< 30 Hz
< 30 Hz
0.02% / K FS
0.02% / K FS
0.02% / K FS
1.5 kVac / 60 s (2)
1.5 kVac / 60 s (2)
1.5 kVac / 60 s (2)
EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
IEC 664-1, DIN VDE
IEC 664-1, DIN VDE
III / 2
III / 2
III / 2
IP 20 IEC 529, EN60529
IP 20 IEC 529, EN60529
IP 20 IEC 529, EN60529
-25…+60°C
-25…+60°C
-25…+60°C
2.5 mm² fixed screw type
2.5 mm² fixed screw type
2.5 mm² fixed screw type
PPE
PPE
PPE
40 g (1.41 oz)
40 g (1.41 oz)
40 g (1.41 oz)
vertical on rail adjacent without gap vertical on rail adjacent without gap vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 Cat. No. X766802
CWBK 7-0803 Cat. No. X766803
CWBK 7-0804 Cat. No. X766804
84
APPLICATIONS
These converters can be used to
convert and isolate the most common standard analogue signals;
each model is designed for a single input output signal function,
and they are the right solution in
applications where many modules
handling the same signal are used,
where they allow a large cost reduction compared with multi function
modules. These modules are provided with 3 ways galvanic isolation
between input output and supply
voltage. If a single signal must
provide several output channels it
is possible to use many modules
connecting their inputs in parallel
as long as the signal is voltage, or
in series when the signal is current.
Analogue signal converters
• 1.5 kV, 3 ways, IN/OUT/supply voltage isolation
• Fixed value
• Compact dimension, 6.2 mm pitch
90
(3.55 in)
6.2
(0.24 in)
92.5
(3.64 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way isolation: IN/OUT/power supply
(3) Version available upon request; for information call our sales
department, local agent or representative
Power supply
24 Vac/dc
VERSIONS
Cat. No. X756533
CWAA 7-0533 (3)
IN: 0...20 mA / OUT: 0...10 V
IN: 0...20 mA / OUT: 0...20 mA
IN: 0...20 mA / OUT: 4...20 mA
Cat. No. X756534
Cat. No. X756535
CWAA 7-0534 (3)
CWAA 7-0535 (3)
INPUT TECHNICAL DATA
Input signal
Input resistance
0...20 mA
100 Ω
0...20 mA
100 Ω
0...20 mA
100 Ω
0...10 V
>1 kΩ
0...20 mA
<400 Ω
4...20 mA
<400 Ω
OUTPUT TECHNICAL DATA
Output signal
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vac/dc (1)
24 Vac/dc (1)
24 Vac/dc (1)
≤ 13 mA ± 10%
≤ 13 mA ± 10%
≤ 13 mA ± 10%
0.1% @ 23°C FS
0.1% @ 23°C FS
0.1% @ 23°C FS
< 30 Hz
< 30 Hz
< 30 Hz
0.02% / K FS
0.02% / K FS
0.02% / K FS
1.5 kVac / 60 s (2)
1.5 kVac / 60 s (2)
1.5 kVac / 60 s (2)
EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
IEC 664-1, DIN VDE
IEC 664-1, DIN VDE
III / 2
III / 2
III / 2
IP 20 IEC 529, EN60529
IP 20 IEC 529, EN60529
IP 20 IEC 529, EN60529
-25…+60°C
-25…+60°C
-25…+60°C
2.5 mm² fixed screw type
2.5 mm² fixed screw type
2.5 mm² fixed screw type
PPE
PPE
PPE
40 g (1.41 oz)
40 g (1.41 oz)
40 g (1.41 oz)
vertical on rail adjacent without gap vertical on rail adjacent without gap vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 Cat. No. X766802
CWBK 7-0803 Cat. No. X766803
CWBK 7-0804 Cat. No. X766804
85
APPLICATIONS
These converters can be used to
convert and isolate the most common standard analogue signals;
each model is designed for a single input output signal function,
and they are the right solution in
applications where many modules
handling the same signal are used,
where they allow a large cost reduction compared with multi function
modules. These modules are provided with 3 ways galvanic isolation
between input output and supply
voltage. If a single signal must
provide several output channels it
is possible to use many modules
connecting their inputs in parallel
as long as the signal is voltage, or
in series when the signal is current.
Analogue signal converters
• 1.5 kV, 3 ways, IN/OUT/supply voltage isolation
• Fixed value
• Compact dimension, 6.2 mm pitch
90
(3.55 in)
6.2
(0.24 in)
92.5
(3.64 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way isolation: IN/OUT/power supply
(3) Version available upon request; for information call our sales
department, local agent or representative
Power supply
24 Vac/dc
VERSIONS
Cat. No. X756536
CWAA 7-0536
IN: 4...20 mA / OUT: 0...10 V
IN: 4...20 mA / OUT: 0...20 mA
IN: 4...20 mA / OUT: 4...20 mA
Cat. No. X756537
Cat. No. X756538
CWAA 7-0537 (3)
CWAA 7-0538
INPUT TECHNICAL DATA
Input signal
Input resistance
4...20 mA
100 Ω
4...20 mA
100 Ω
4...20 mA
100 Ω
0...10 V
>1 kΩ
0...20 mA
<400 Ω
4...20 mA
<400 Ω
OUTPUT TECHNICAL DATA
Output signal
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vac/dc (1)
24 Vac/dc (1)
24 Vac/dc (1)
≤ 13 mA ± 10%
≤ 13 mA ± 10%
≤ 13 mA ± 10%
0.1% @ 23°C FS
0.1% @ 23°C FS
0.1% @ 23°C FS
< 30 Hz
< 30 Hz
< 30 Hz
0.02% / K FS
0.02% / K FS
0.02% / K FS
1.5 kVac / 60 s (2)
1.5 kVac / 60 s (2)
1.5 kVac / 60 s (2)
EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4 EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
IEC 664-1, DIN VDE
IEC 664-1, DIN VDE
III / 2
III / 2
III / 2
IP 20 IEC 529, EN60529
IP 20 IEC 529, EN60529
IP 20 IEC 529, EN60529
-25…+60°C
-25…+60°C
-25…+60°C
2.5 mm² fixed screw type
2.5 mm² fixed screw type
2.5 mm² fixed screw type
PPE
PPE
PPE
40 g (1.41 oz)
40 g (1.41 oz)
40 g (1.41 oz)
vertical on rail adjacent without gap vertical on rail adjacent without gap vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 Cat. No. X766802
CWBK 7-0803 Cat. No. X766803
CWBK 7-0804 Cat. No. X766804
86
APPLICATIONS
These converters can be used
to convert and isolate the most
common standard analog signals;
each model is designed for a
single input output signal function,
and they are the right solution in
applications where many modules
handling the same signal are
used, where they allow a large
cost reduction compared with multi
function modules. These modules
are provided with 3 ways galvanic
isolation between input output
and supply voltage. If a single
signal must provide several output
channels it is possible to use many
modules connecting their inputs in
parallel as long as the signal is
voltage, or in series when the signal
is current
Passive galvanic isolators
• Do not require power supply
• Suitable for loop powered sensors
• 2 Ways I/O 500 V isolation
• Single and double channel version
• Compact dimension, 6.2 mm pitch
90
(3.55 in)
6.2
(0.24 in)
90
(3.55 in)
115,5
(4.55 in)
6.2
(0.24 in)
115,5
(4.55 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) Input voltage must have a value higher than the value
calculated with this formula, where Rb is load resistance (see
pic.1); for calculation refer to the diagram comparing minimum
input voltage with output load and wires resistance values; refer
to the diagram (see pic. 2) to define if application conditions
allow to get full 20 mA output signal
(2) 2-way isolation: IN/OUT
(3) Version available upon request; for information call our
sales department, local agent or representative
VERSIONS
4
3
5
2
Cat. No. X756526
CWPAA 7-0526
Single channel
Double channel
Cat. No. X756527
CWPAA 7-0527 (3)
INPUT TECHNICAL DATA
Input signal
Input current
Input voltage (1)
Input resistance
1 channel 0…20 mA, 4…20 mA
—
2.7 + (20 mA x Rb)
100 Ω
2 channels 0…20 mA, 4…20 mA
—
2.7 + (20 mA x Rb)
100 Ω
1 channel 0…20 / 4…20 mA, (max 21
mA)
<400 Ω with output current
2 channels 0…20 / 4…20 mA, (max 21 mA)
—
12 mA
0.1 FS (23°C)
10 ms
30 Hz @ 3 dB
0.02% FS
1.5 kVac / 60 s (2)
EN 61000-6-2, EN 61000-6-4
IED 664-1, DIN VDE
III / 2
IP 20 IEC 529 EN60529
-25…+60°C
1.5 mm² fixed screw type
Luranyl
35 g (1.24 oz)
vertical on rail adjacent without gap
—
12 mA
0.1 FS (23°C)
10 ms
30 Hz @ 3 dB
0.02% FS
1.5 kVac / 60 s (2)
EN 61000-6-2, EN 61000-6-4
IED 664-1, DIN VDE
III / 2
IP 20 IEC 529 EN60529
-25…+60°C
1.5 mm² fixed screw type
Luranyl
35 g (1.24 oz)
vertical on rail adjacent without gap
OUTPUT TECHNICAL DATA
Output signal
Applicable load
<400 Ω with output current
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Rise time (10..90%)
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
figure 1
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 Cat. No. X766802
CWBK 7-0803 Cat. No. X766803
CWBK 7-0804 Cat. No. X766804
figure 2
87
APPLICATIONS
The passive galvanic isolators can
isolate the signal generated by loop
powered sensors, where the applied
load must have a resistance lower
than 400 Ω 20 mA, including the
cable resistance; the applied input
voltage has to be higher than 2.7
V compared with output voltage
(see note 2). If above conditions are
satisfied, passive isolators reduce
cabling costs and eliminate power
supplies thereby saving costs. If
above conditions are not satisfied,
passive module introduces a signal
attenuation.
Analogue signal
limit value switch
90
• 3 ways I/O 2.5 kV isolation
• programmable input ranges via dip-switch and customizable
via software FDT/DTM
• 2 threshold customizable via software FDT/DTM
• Symple functions programming
115,5
6.2
Programming tool X756894
NOTES
BLOCK DIAGRAM
Serial interface
The dimensions includes the DIN clamp.
(1) Version available upon request; for information call our
sales department, local agent or representative
(2) Input temperature ranges can be set via dip switch and
adjustable via FDT/DTM software.
Output ranges can be set via FDT/DTM software
(3) 3-way isolation: IN / OUT/ supply
LED
IN:
+
+
+
_
–22
4+
_
3 –14 OUT
+
2+
_ PwrPwr
1–
5 U
6 I
7 I
8
+V
5
4
+–24
+ mA
6
3
_–14
OUT:
OUT: K1,
I, U K2
+A
VERSION
Cod. X756360
LCONALSFDT (1)
Cod. X756894
(1)
LCONZBUSB (1)
INPUT TECHNICAL DATA
Input signal (1)
Input resistance
Zero / Spam
-30…+30 V
330 kΩ
-50…+50 mA
30 Ω
adjustable via software FDT/DTM
-5…+5 A
10 mΩ
OUTPUT TECHNICAL DATA
Threshold regulation
Contact type
Max. switching voltage / current
Status indication
Operating mode
programmable via software FDT/DTM
2 NO contact (solid state relay)
30 Vdc / 100 mA
2 yellow LED
limit value, window, tendency, inverting and hold function
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Data processing
Linearity error
Temperature coefficient
Response time
Isolation
EMC Standard
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vdc (16.8…30 Vdc)
18 mA ± 10% @ 24 Vdc
0.1% FS
24 Bit
< 100 ppm FS
<100 ppm/°C
1...500 ms (adjustable, default 30 ms)
2.5 kVac / 60 s (3)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
III / 2
IP20
-40…+70°C
1.5 mm² fixed screw type
Noryl UL94V-0
600 g
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 cod. X766802
CWBK 7-0803 cod. X766803
CWBK 7-0804 cod. X766804
88
++11
2
Power
DC 24 V
- GND
With screw terminals (standard)
With spring terminals
Programming tool
7
8
1
_
APPLICATIONS
CWTPR 7-0360 is an analog signal
conveter that provides high accuracy measurement and that can
be connected to a wide range of
analogue sensors.
Input range and the output thresholds can be modified with a FDT/
DTM software and an USB interface.
Are available two normally open
contact with solid state relay.
Temperature transducer
• For PT100, PT1000 sensors, thermocouples, potentiometers
• 3 ways I/O 2.5 kV isolation
• 145 programmable input ranges via dip-switch and customizable
via software FDT/DTM
• 5 programmable output ranges via dip-switch and customisable
via software FDT/DTM
• Compact dimension, 6.2 mm pitch
90
(3.55 in)
115,5
(4.55 in)
6.2
(0.24 in)
Programming tool X756894
NOTES
The dimensions includes the DIN clamp.
(1) Version available upon request; for information
call our sales department, local agent or
representative
(2) Input temperature ranges, and output signals,
can be set via dip switch, or adjustable via FDT/
DTM software.
(3) 3-way isolation: IN / OUT/ supply
BLOCK DIAGRAM
RTD
5
5
6
5
6
8
8
7
8
5
6
7
8
5
5
6
5
6
8
7
8
5
6
8
8
5
6
7
8
+
_
4
3
2
1
+
_
+
_
+
_
U,I
Pwr
+
_
6
+
_
U,I
Pwr
Cod. X756340
LCONTADFDT (1)
4
3
2
1
Temperature range
IN:
RTD
Poti
KTY
TC
+
_
5
4
6
3
+
7
_
+
2
8
1
_
+
_
APPLICATIONS
Cod. X756894
(1)
LCONZBUSB (1)
INPUT TECHNICAL DATA
Input signal
LED
Power
DC 24 V
7
VERSIONS
Pwr
4
3
2
1
OUT: I, U
R
TC
With screw terminals (standard)
With spring terminals
Programming tool
Serial interface
U,I
PT100, PT1000 sensor
potenziometer 0…600kΩ
therrmocouple B, C, E, J, K, N, R, S, T type
-200…+1400°C, according to sensor type (2)
CSWTPR 7-0340 is a temperature to analog signal conversion module that
provides high accuracy measurement and that can be connected to a wide
range of temperature sensors. The module can be used for a temperature
range from -200 to + 1.400°C.
With resistive sensors it is possible to select among 2, 3, 4 wire connections.
Input and output ranges can be modified with a FDT/DTM software and an
USB interface.
OUTPUT TECHNICAL DATA
Output signal
Applicable load
Display signals
0…10 / -10…+10 V, (max. 10.25 V)
0…20 / 4…20 mA, (max 21 mA)
(2)
>2 kΩ with output voltage
<650 Ω with output current
green LED = OK , flashing red LED = error
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Data processing
Linearity error
Temperature coefficient
Response time
Isolation
ECM standards
Reference Standard
Overvoltage category / Pollution degree
Protection degree
Operating temperature
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vdc (16.8...30 Vdc)
18 mA max. @ 24 Vdc
10K/span(K) + 0.2% FS (for RTD) / 10K/span(K) + 0.4% FS (for TE)
24 bit
±0.05% FS – ±0.1% FS (for TE)
<100 ppm/°C
5...500 ms (regolabile, default 30 ms)
2.5 kVac / 60 s
(3)
EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
III / 2
IP 20 IEC 529 EN60529
-40…+70°C
1.5 mm² fixed screw type
PPE
40 g (1.41 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 cod. X766802
CWBK 7-0803 cod. X766803
CWBK 7-0804 cod. X766804
89
Range*
Start
S1
7 8 1 2 End
S2
345678
0°C
50°C
100°C
150°C
200°C
250°C
Sensor* S1 1 2 3
300°C
Pt100
350°C
Pt1000
400°C
TE J
450°C
TE K
500°C
R
550°C
600°C
Output* S1 4 5 6
650°C
0 20mA
700°C
4 20mA
750°C
0 10V
800°C
±10V
850°C
900°C
S1-S2 1-8 off:
950°C
FDT/DTM
1000°C
*See instruction
1050°C
leaflet
1100°C
1150°C
1200°C
1250°C
1300°C
1350°C
1400°C
Switch On
-200°C
-150°C
-100°C
-50°C
0°C
Temperature limit
value switch
90
(3.55 in)
• For PT100, PT1000 sensors, thermocouples, potentiometers
• 3 ways I/O 2.5 kV isolation
• 145 programmable input ranges via dip-switch and customizable
via software FDT/DTM”
• 2 threshold customizable via software FDT/DTM
• Compact dimension, 6.2 mm pitch
115,5
(4.55 in)
6.2
(0.24 in)
Programming tool X756894
NOTES
The dimensions includes the DIN clamp.
(1) Version available upon request; for information
call our sales department, local agent or
representative
(2)Input temperature ranges can be set via dip
switch and adjustable via FDT/DTM software.
Output ranges can be set via FDT/DTM software
(3) 3-way isolation: IN/OUT/power supply
BLOCK DIAGRAM
RTD
5
5
6
5
6
8
8
7
8
5
6
5
6
5
8
7
8
4
3
2
1
5
6
7
8
R
6
8
8
+
5
6
7
8
_
–14
+
_+
–
PwrPwr
6
7
4
3
2
1
–22
+
_
–14 OUT
+
_+– PwrPwr
4
3
2
1
Cod. X756370
LCONTLSFDT (1)
–22
+
_ OUT
Temperature range
–
Cod. X756894
(1)
LCONZBUSB (1)
PT100, PT1000 sensor
potenziometer 0…600kΩ
therrmocouple B, C, E, J, K, N, R, S, T type
-200…+1400°C, according to sensor type (2)
programmable via software FDT/DTM
2 NO contact (solid state relay)
30 Vdc / 100 mA
2 yellow LED
limit value, window, tendency, inverting and hold function
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Data processing
Linearity error
Temperature coefficient
Response time
Isolation
ECM standards
Reference Standard
Overvoltage category / Pollution degree
Protection degree
Operating temperature
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vdc (16.8...30 Vdc)
18 mA max. @ 24 Vdc
10K/span(K) + 0.2% FS (for RTD) / 10K/span(K) + 0.4% FS (for TE)
24 bit
±0.05% FS (for RTD and potentiometer) / ±0.1% FS (for TE)
<100 ppm/°C
5...500 ms (regolabile, default 30 ms)
2.5 kVac / 60 s (3)
EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
III / 2
IP 20 IEC 529 EN60529
-40…+70°C
1.5 mm² fixed screw type
PPE
40 g (1.41 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
red
white
blue
4
+–24
RTD
Poti
KTY
TC
6
3
_–14
7
++11
2
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 cod. X766802
CWBK 7-0803 cod. X766803
CWBK 7-0804 cod. X766804
90
8
1
_
PwrPwr
OUTPUT TECHNICAL DATA
Threshold regulation
Contact type
Max. switching voltage / current
Status indication
Operating mode
5
–14
+
_+
INPUT TECHNICAL DATA
Input signal
IN:
Power
DC 24 V
+
_
VERSIONS
–22
+
_ OUT
OUT:
UK
OUT: I,
K1,
5
TC
With screw terminals (standard)
With spring terminals
Programming tool
Serial interface
LED
APPLICATIONS
CWTPR 7-0370 is a temperature to analogue signal conversion module that
provides high accuracy measurement and that can be connected to a wide
range of temperature sensors. The module can be used for a temperature
range from -200 to + 1.400°C. With resistive sensors it is possible to select
among 2, 3, 4 wire connections.
Input range and the output thresholds can be modified with a FDT/DTM
software and an USB interface.
Two normally open contact with solid state relay are available.
Temperature transducer
• Converters for PT100 sensors
• 3 ways galvanic isolation
• 8 programmable input range
• 3 programmable output range
• Simple programming
• Version with 24-240 Vac/dc supply voltage
79
(3.11 in)
17.5
(0.69 in)
84
(3.31 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) Adjustable via rotary-switch
(2) Adjustable via dip-switch
(3) They can also be used with 2 wire PT100 sensor, connecting
the terminals 1 and 4
(4) range 16.8…30 Vdc / 19.2…28.8 Vac
(5) range 16.8…264 Vdc / 19.2…264 Vac
(6) 3-way isolation: IN/OUT/power supply
(7) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Supply voltage
24 Vac/dc
Cat. No. X756816
CWPT 6-0816
24 Vac/dc supply voltage
24-240 Vac/dc supply voltage
Supply voltage
24…240 Vac/dc
Cat. No. X756817
CWPT 6-0817 (7)
INPUT TECHNICAL DATA
Input signal
Temperature range (1)
Supply current
PT100 3 wires (3)
-50…+50°C (-58…+122°F)
-50…+100°C (-58…+212°F)
-50…+150°C (-58…+302°F)
0…+100°C (+32…+212°F)
0…+150°C (+32…+302°F)
0…+200°C (+32…+392°F)
0…+300°C (+32…+572°F)
0…+400°C (+32…+752°F)
0.5 mA
PT100 3 wires (3)
-50…+50°C (-58…+122°F)
-50…+100°C (-58…+212°F)
-50…+150°C (-58…+302°F)
0…+100°C (+32…+212°F)
0…+150°C (+32…+302°F)
0…+200°C (+32…+392°F)
0…+300°C (+32…+572°F)
0…+400°C (+32…+752°F)
0.5 mA
0…10 V
0…20 / 4…20 mA
>1 kΩ with output voltage,
<400 Ω with output current
0…10 V
0…20 / 4…20 mA
>1 kΩ with output voltage,
<400 Ω with output current
24 Vac/dc (2)
≤ 35 mA ± 10% @ 24 Vdc
<0.3% FS
<30 Hz
0.015% / K FS
1.5 kVac / 60 s (6)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
III / 2
IP20
-20…+60°C
2.5 mm² fixed screw type
Noryl UL94V-0
75 g (2.65 oz)
vertical on rail adjacent without gap
24-240 Vac/dc (3)
≤ 35 mA ± 10% @ 24 Vdc
<0.3% FS
<30 Hz
0.015% / K FS
4 kVac / 60 s (6)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
III / 2
IP20
-20…+60°C
2.5 mm² fixed screw type
Noryl UL94V-0
85 g (3.00 oz)
vertical on rail adjacent without gap
OUTPUT TECHNICAL DATA
Output signal (2)
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
91
APPLICATIONS
The modules convert and isolate
signals generated by 3 wire / 2 wire
PT100 (RTD) sensors into analogue
signals; the module can be set into
8 temperature ranges and for up to
3 most important analogue ranges.
Set up is easily achieved by setting
a dip-switch on one side of the
module.
The modules provide input and
output isolation, assuring high
signal accuracy, and can be used
with isolated and not isolated
sensors. Two wire sensors can be
used by connecting a jumper wire
between 1 and 4 terminal blocks.
Temperature transducer
• Converters for sensors with thermocouples J and K type
• 3 ways galvanic isolation
• 8 programmable input range
• 3 programmable output range
• Simple programming
79
(3.11 in)
17.5
(0.69 in)
84
(3.31 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the DIN clamp.
(1) Adjustable via rotary-switch
(2) Adjustable via dip-switch
(3) range 16.8…30 Vdc / 19.2…28.8 Vac
(4) range 16.8…264 Vdc / 19.2…264 Vac
(5) “3-way isolation: IN/OUT/power supply
(7) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Supply voltage
24 Vac/dc
Cat. No. X756844
CWTH 6-0844
24 Vac/dc supply voltage
24-240 Vac/dc supply voltage
Supply voltage
24…240 Vac/dc
Cod. X756847
CWTH 6-0847 (7)
INPUT TECHNICAL DATA
Input signal
Temperature range (1)
Supply current
thermocouples FeCuNi (J type) e NiCrNi (K type)
according to DIN/IEC584-1
-50…+200°C (-58…+392°F)
-50…+350°C (-58 …+662°F)
0…+200°C (+32…+392°F)
0…+400°C (+32…+752°F)
0…+600°C (+32…+1112°F)
0…+800°C (+32…+1472°F)
0…+1000°C (+32…+1832°F)
0…+1200°C (+32…+2192°F)
—
termocoppia FeCuNi (tipo J) e NiCrNi (tipo K)
conformi a DIN/IEC584-1
-50…+200°C (-58…+392°F)
-50…+350°C (-58 …+662°F)
0…+200°C (+32…+392°F)
0…+400°C (+32…+752°F)
0…+600°C (+32…+1112°F)
0…+800°C (+32…+1472°F)
0…+1000°C (+32…+1832°F)
0…+1200°C (+32…+2192°F)
—
0…10 V
0…20 / 4…20 mA
>1 kΩ with output voltage,
<400 Ω with output current
0…10 V
0…20 / 4…20 mA
>1 kΩ con uscita in tensione,
<400 Ω con uscita in corrente
24 Vac/dc (3)
≤ 35 mA ± 10% @ 24 Vdc
<0.5% FS
<30 Hz
0.015% / K FS
1.5 kVac / 60 s (5)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
III / 2
IP20
-20…+60°C
2.5 mm² fixed screw type
Noryl UL94V-0
65 g (2.29 oz)
vertical on rail adjacent without gap
24-240 Vac/dc (4)
≤ 35 mA ± 10% @ 24 Vdc
<0.5% FS
<30 Hz
0.015% / K FS
4 kVac / 60 s (5)
EN 50081-2, EN 50082-2
IEC 664-1, DIN VDE
III / 2
IP20
-20…+60°C
morsetti a vite 2.5 mm2, fissi
Noryl UL94V-0
75 g
verticali su guida, affiancati
OUTPUT TECHNICAL DATA
Output signal (2)
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Trasmission frequency
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category/Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
92
APPLICATIONS
The modules convert and isolate
signals generated by thermocouples
type J (FeCuNi) or K (NiCrNi) into an
analogue signal; can be set into 8
temperature input ranges, and can
be set for up to 3 most important
analogue ranges. The set up is
possible by setting a dip-witch on
one side of the module.
The modules provide input and
output isolation, assuring high
signal accuracy, and can be used
with isolated and not isolated
sensors.
Current limit value switch
• For AC current measure
• Adjustable threshold value
• Versions with transistor or relay output
• IN/OUT 3 kV isolation
93
(3.66 in)
50
(1.97 in)
70
(2.76 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the terminal blocks and the DIN clamp.
(1) Isolation referred to conductor being measured, not isolated
(naked) and in contact with the wall of the toroid. By using
isolated conductors, the isolation value of the conductor is
added to isolation of the module.
MAINS
(A) AC load
(B) Threshold
(C) Output with SPDT contact
(D) Digital input drive by transistor
Power supply
24 Vac/dc
LOAD
VERSIONS
Cod. XCCIS2
CCIS-2
INPUT TECHNICAL DATA
Max. measured current
Max. measured voltage
Frequency
Sensor’s hole diameter
50 A (AC)
600 Vac (1)
50…60 Hz
Ø 13 mm
OUTPUT TECHNICAL DATA
Threshold regulation
Threshold hysteresis
Max. output current
Output status
2…40 A
± 10%
100 mA open collector PNP
“high” 24 V (closed) with l < threshold
“low” 0 V (open) with l > threshold
20 ms
Response time
GENERAL TECHNICAL DATA
Supply voltage
Max rated current
Operating temperature range
Input/output isolation
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vdc ± 10%
100 mA
0…60°C
> 3 kVac /60 s
2.5 mm2 fixed screw type (14 AWG)
polyamide UL94V-03
100 g (3.53 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AS
PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
—
—
—
93
APPLICATIONS
This module converts a current
flowing through circuit into a threshold that can be adjusted by the
potentiometer; when the current
reaches the threshold value, the
relay or the transistor switches; the
wire must be feed through the hole
of the current sensor for current
detection.
Current transducers
• For AC/DC current measurements
• Protected against transients
• Power supplied LED
• 3 output signals available
90
(3.70 in)
115,5
(3.90 in)
6.2
(0.99 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the terminal blocks and the DIN
clamp.
(1) Do not connect directly to a 400 V line
IN
7
IN
8
I
_ 1
U,I
4
OUT+
3
OUT-
+ 2
DC 24V
VERSIONS
Cod. X756540
WAA 7-0540
0…1 A input
0…5 A input
0…10 A input
Cod. X756541
Cod. X756542
WAA 7-0541
WAA 7-0542
INPUT TECHNICAL DATA
Input signal
Max. input voltage
Current wire connection
0…1 A AC/DC
400 V (1)
1.5 mm² screw type
OUTPUT TECHNICAL DATA
0…5 A AC/DC
400 V (1)
1.5 mm² screw type
VOLTAGE
0…10 V
11 V
>1 kΩ
Output signal
Max. output signal
Applicable load
0…10 A AC/DC
400 V (1)
1.5 mm² screw type
CURRENT
0…20 mA / 4…20 mA
21 mA
<400 Ω
APPLICATIONS
Through a “HALL” sensor they grant
AC/DC current measurements.
The presence of current in a circuit
indicates not only that power is
supplied but also that the circuit
is closed and the load connected
and active.
It’s also possible to know the work
conditions of the circuit.
The module guarantees galvanic
isolation between the current
conductor and the analogue.
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Operating temperature
Linearity error
Offset error
Temperature coefficient
Response time
Protection degree
Connection terminal
Approx. weight
Mounting information
24 Vdc (16.8...30 Vdc)
24 Vdc (16.8...30 Vdc)
24 Vdc (16.8...30 Vdc)
13 mA
13 mA
13 mA
-25…+60°C
-25…+60°C
-25…+60°C
< 0.1% FS (23°C)
< 0.1% FS (23°C)
< 0.1% FS (23°C)
< 0.5% FS (23°C)
< 0.5% FS (23°C)
< 0.5% FS (23°C)
< 150 ppm / K FS
< 150 ppm / K FS
< 150 ppm / K FS
150 ms
150 ms
150 ms
IP20
IP20
IP20
1.5 mm² screw type
1.5 mm² screw type
1.5 mm² screw type
55 g (1.94 oz)
55 g (1.94 oz)
55 g (1.94 oz)
vertical on rail adjacent without gap vertical on rail adjacent without gap vertical on rail adjacent without gap
0-1A
0-1A
0-1A
S1
Switch On
Output 1 2 3 4
0-10V
0-20mA
4-20mA
Range WAA7-0540
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
Input
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 cod. X766802
CWBK 7-0803 cod. X766803
CWBK 7-0804 cod. X766804
Input
0-5A
0-5A
0-5A
S1
Switch On
Output 1 2 3 4
0-10V
0-20mA
4-20mA
Range WAA7-0541
Input
0-10A
0-10A
0-10A
S1
Switch On
Output 1 2 3 4
0-10V
0-20mA
4-20mA
Range WAA7-0542
94
Current transducers
• For AC/DC current measurements
• Protected against transients
• Power supplied LED
• 3 output signals available
94
(3.70 in)
25
(0.99 in)
NOTES
99
(3.90 in)
BLOCK DIAGRAM
The dimensions includes the terminal blocks and the DIN
clamp.
Article available until sell-out
XW000928 will be replaced by X756540
XW000929 will be replaced by X756541
XW000930 will be replaced by X756542
VERSIONS
Cat. No. XW000928
SW01VA
0…1 A input
0…5 A input
0…10 A input
Cat. No. XW000929
Cat. No. XW000930
SW05VA
SW10VA
INPUT TECHNICAL DATA
Input signal
Max. input voltage
Current wire connection
0…1 A AC/DC
0…5 A AC/DC
0…10 A AC/DC
380 V
380 V
380 V
2.5 mm² pluggable screw type 2.5 mm² pluggable screw type 2.5 mm² pluggable screw type
VOLTAGE
CURRENT
0…10 V
0…20 mA / 4…20 mA
11 V
22 mA
>2 kΩ
<500 Ω
OUTPUT TECHNICAL DATA
Output signal
Max. output signal
Applicable load
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Operating temperature
Linearity error
Offset error
Amplification error
Temperature coefficient
Surge immunity
Response time
Protection degree
Connection terminal
Approx. weight
Mounting information
24 Vdc ± 10%
24 Vdc ± 10%
24 Vdc ± 10%
60 mA
60 mA
60 mA
0…55°C
0…55°C
0…55°C
< 0.5%
< 0.5%
< 0.5%
< 0.5%
< 0.5%
< 0.5%
< 0.2%
< 0.2%
< 0.2%
< 0.02%/K
< 0.02%/K
< 0.02%/K
200 V
200 V
200 V
10 mS
10 mS
10 mS
IP20
IP20
IP20
2.5 mm² pluggable screw type 2.5 mm² pluggable screw type 2.5 mm² pluggable screw type
100 g (3.53 oz)
100 g (3.53 oz)
100 g (3.53 oz)
vertical on rail adjacent without gap vertical on rail adjacent without gap vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
95
APPLICATIONS
In 99 mm depth measure is included
the space occupied by the terminal
block provided with the product.
Through a “HALL” sensor they grant
AC/DC current measurements.
The presence of current in a circuit
indicates not only that power is
supplied but also that the circuit
is closed and the load connected
and active.
It’s also possible to know the work
conditions of the circuit.
The module guarantees galvanic
isolation between the current
conductor and the analogue output
and, if not connected in series to
the controlled current, cannot be
damaged by power surges or short
circuits.
Current transducers
• For AC/DC current measurements
• Protected against transients
• Power supplied LED
• 3 output signals available
94
(3.70 in)
25
(0.99 in)
NOTES
99
(3.90 in)
Article available until sell-out
BLOCK DIAGRAM
The dimensions includes the terminal blocks and the DIN
clamp.
VERSIONS
Cat. No. XW000931
SW20VA
0…20 A input
0…50 A input
Cat. No. XW000932
SW50VA
INPUT TECHNICAL DATA
Input signal
Max. input voltage
Current wire connection
0…20 A AC/DC
380 V
Ø 8 mm
OUTPUT TECHNICAL DATA
0…50 A AC/DC
380 V
Ø 8 mm
VOLTAGE
0…10 V
11 V
>2 kΩ
Output signal
Max. output signal
Applicable load
CURRENT
0…20 mA / 4…20 mA
22 mA
<500 Ω
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Operating temperature
Linearity error
Offset error
Amplification error
Temperature coefficient
Surge immunity
Response time
Protection degree
Connection terminal
Approx. weight
Mounting information
24 Vdc ± 10%
60 mA
0…55°C
< 0.5%
< 0.5%
< 0.2%
< 0.02%/K
200 V
10 mS
IP20
2.5 mm² pluggable screw type (14 AWG)
100 g (3.53 oz)
vertical on rail adjacent without gap
24 Vdc ± 10%
60 mA
0…55°C
< 0.5%
< 0.5%
< 0.2%
< 0.02%/K
200 V
10 mS
IP20
2.5 mm² pluggable screw type (14 AWG)
100 g (3.53 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Plug-in jumper
(16 poles, 16 A)
red
white
blue
PR/3/AC, PR/3/AS
PR/DIN/AC, PR/DIN/AS, PR/DIN/AL
—
—
—
96
APPLICATIONS
In 99 mm depth measure is
included the space occupied by
the terminal block provided with
the product.
They allow the user to measure AC/
DC currents by an “HALL” sensor.
The presence of current in a circuit
indicates not only that power is
supplied but also that the circuit is
closed and the load connected and
active. It is also possible to know the
working conditions of the controlled
circuit.
The module guarantees galvanic
isolation between the current
conductor and the analogue output
and, if not connected in series to
the controlled current, cannot be
damaged by power surges or short
circuits.
Frequency signal converter
• Adjustable frequency range 0...28.8 Khz
• 3 programmable analogue signal output ranges
• 3 ways I/O 2.5 kV isolation
79
(3.11 in)
17.5
(0.69 in)
84
(3.31 in)
NOTES
The dimensions includes the terminal blocks and
the DIN clamp.
(1) range 16.8…30 Vdc / 19.2…28.8 Vac
(2) 3-way isolation: IN/OUT/power supply
BLOCK DIAGRAM
F
OUT+
GND
Shield-
OUT-
Alimentazione
AC/DC 24V
24…240 Vac/dc
VERSIONS
APPLICATIONS
Cat. No. X756524
CWNFA 6-0524
INPUT TECHNICAL DATA
Input signal (range)
Input signal (type)
Input resistance
Hysteresis
0…28.8 kHz adjustable via DIP switch
AC/DC 0.6…30 Vpp
50 kΩ
0.5 Vpp o 5 Vpp adjustable via DIP switch
OUTPUT TECHNICAL DATA
Output signal
Applicable load
Ripple
0…10 V, (max. 10.6 V)
0…20 / 4…20 mA, (max 21 mA)
>1 kΩ with output voltage
<400 Ω with output current
< 5 mVeff
GENERAL TECHNICAL DATA
Supply voltage
Rated current
Accuracy
Linearity error
Ripple
Setting time (accuracy 1%)
Temperature coefficient
Isolation
ECM standards
Reference Standard
Overvoltage category
Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
24 Vac/dc (1)
20 mA
0.1 FS (23°C)
0.02%
0.1%
200 ms
70 ppm/K
1.5 kVac / 60 s (2)
EN 61000-6-2, EN 61000-6-4
IED 664-1, DIN VDE
III
2
IP 20 IEC 529 EN60529
-25…+60°C
1.5 mm² fixed screw type
PPE
70 g (2.47 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
97
This module is used to convert a frequancy signal, with either sinusoidal
or square waveform, into a standard analogue signal (eg. 0…10 V, 0..20
mA, 4…20 mA). A microprocessor provides a high resolution, high stability
and accuracy output signal and a dip switch gives the possibility to select
a calibrated range of frequency measurement from 0 … 100 Hz up to
0…28.8 kHz.
Auxiliary supply output for
sensors and potentiometers
90
(3.55 in)
• Stabilized switching converter
• IN 16.8…20 Vdc / 9…11 Vdc 60 mA
• Suitable to feed potentiometers and sensors
92.5
(3.64 in)
6.2
(0.24 in)
NOTES
BLOCK DIAGRAM
EXAMPLE
The dimensions includes the DIN clamp.
(1) range 16.8…30 Vdc
+4
IN
+3
24 Vdc
-5
-6
-1
+4
-2
9...11 Vdc
9...11 Vdc
VERSIONS
With screw connection (standard)
With spring connection
24 Vdc (1)
30 mA @ 10 Vdc
T 1 A (external)
10 Vdc (9…11 Vdc adjustable)
60 mA
60 mA
< 1%
≤ 50 mVpp
sì
yellow LED Power OK
possible with external diode
GENERAL TECHNICAL DATA
Operating temperature range
Input/output isolation
Protection degree
EMC Standards
Surge immunity
Connection terminal
Housing material
Approx. weight
Mounting information
-25...+60°C
50 Vac / 60 s
IP 20 IEC529, EN60529
EN 50081-1, EN 50082-2, EN 61000-3-2
EN61000-4-2, EN61000-4-4
1.5 mm2 screw type / 1.5 mm2 spring type (16 AWG)
Noryl UL94V-0
35 g (1.24 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
red
white
blue
0...10 V
-1
10 Vdc
CWCV 7-6184
4...20 mA
SIGNAL
POTENZIOMETRO
POTENTIOMETER CONVERTITORE
CONVERTER
DI SEGNALE
For the highest accuracy of electronic measurements in process
control and automation systems, a stable supply source is required
to feed reference voltages. Accuracy of position sensors, such as
linear or rotary potentiometers, depends greatly on the stability and
accuracy of the DC supply of the sensor. For this reason our modules
are provided with a calibrated DC output dedicated to feed the sensor
for the highest accuracy, and this feature also helps to save space
and the cost of an external DC supply source.
OUTPUT TECHNICAL DATA
Voltage
Maximum current
Continuous current
Load regulation
Ripple @ rated U-I output
Overload / short circuit protection
Output signal
Parallel connection
-5
+3
APPLICATIONS
Cat. No. X766184
CWCV 7-6184
INPUT TECHNICAL DATA
Rated voltage
Current @ lout max.
Protection fuse
24 Vdc
OUT
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
CWBK 7-0802 Cat. No. X766802
CWBK 7-0803 Cat. No. X766803
CWBK 7-0804 Cat. No. X766804
98
NPN and PNP signal polarity
inverter
• Converts a NPN sensor in a PNP sensor and vice versa
• Compact design
77
(3.03 in)
12
(0.47 in)
45
(1.77 in)
NOTES
BLOCK DIAGRAM
The dimensions includes the terminal blocks and the
DIN clamp.
(1) range 17...30 Vdc
NPN
+
PNP
–
VERSIONS
APPLICATIONS
Cat. No. XNPNPNP
CI-NPN/PNP
It converts signal form PNP sensors into NPN signal and vice versa. It
allows to adapt the PLC inputs to all sensors on the market, regardless of their output polarity, and it is a great help for maintenance and
allows in any case a quick replacement of failed sensors when you
need a PNP sensor but you have a NPN type.
INPUT TECHNICAL DATA
Input voltage
Max. current
Max. frequency
24 Vdc (1)
200 mA
120 kHz
GENERAL TECHNICAL DATA
OFF state current
ECM standards
Reference Standard
Overvoltage category
Pollution degree
Protection degree
Operating temperature range
Connection terminal
Housing material
Approx. weight
Mounting information
—
EN 61000-6-2, EN 61000-6-4
IEC 664-1, DIN VDE
II
2
IP 20 IEC 529 EN60529
0...55°C
morsetti a vite 2.5 mm2 fissi
Poliammide UL94V-0
20 g (0.71 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Plug-in jumper
red
white
blue
PR/3/AC, PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
—
—
EXAMPLE
load
carico
PNP sensor
sensore
PNP
E
Conversion from PNP to NPN
24 V
n.c.
C
2
1
0V
CI-NPNPNP
3
IN
4
NPN sensor
sensore
NPN
load
carico
24 V
Conversion from NPN to PNP
2
C
n.c.
E
0V
1
CI-NPNPNP
3
IN
4
99
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Output
Number of
relays
Input
rated voltage
type / no. of contacts
rated current
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
1
1
1
1
1
1
1
1
1
1
1
1
1
12 Vdc
12 Vdc
12 Vdc
12 Vdc
12 Vac
12 Vac
12 Vac/dc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac
24 Vac
48 Vdc
48 Vdc
48 Vac/dc
110 Vdc
110 Vdc
110...120 Vac/dc
120 Vac
120 Vac
230 Vac
230 Vac
230 Vac
SPDT
SPDT
DPDT
4PDT
SPDT
DPDT
SPDT
SPST(NO)
SPDT
SPDT
SPDT
SPDT
SPDT
DPDT
4PDT
SPDT
SPDT
DPDT
DPST(NO)
SPDT
DPDT
SPDT
DPDT
SPDT
SPDT
DPDT
SPDT
SPDT
DPDT
SPDT
SPDT
DPDT
16A
10A
5A
3A
10A
5A
6A
5A
16A
16A
12A
12A
12A
8A
3A
6A
6A
8A
5A
12A
8A
10A
5A
6A
10A
5A
6A
10A
5A
6A
10A
5A
(2)
(1)
(1)
(1)
(1)
(1)
(1)
(2)
(1)
(2)
(1)
(1)
(2)
(1)
(1)
(1)
(2) (3)
(1)
(2)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Notes
(1)
(2)
(3)
(4)
Notes
version with pluggable relay
version with fixed relay
protection fuse on the contact
without LED and protection diode
100
Type
RF1012D
CM1C012
CM2C012
CM4C012
CM1A012
CM2A012
CWRE7-0848
RFA024D
RE1024D
RF1024D
CM1C024
RE1824D
RF1824D
CM2C024
CM4C024
CWRE7-0842
CKR16
RE2024D
CKR25
CM1A024
CM2A024
CM1C048
CM2C048
CWRE7-0845
CM1C110
CM2C110
CWRE7-0846
CM1A120
CM2A120
CWRE7-0847
CM1A230
CM2A230
Cat. No.
Page
XRF1012D
XCM1C012
XCM2C012
XCM4C012
XCM1A012
XCM2A012
X766848
XRFA024D
XRE1024D
XRF1024D
XCM1C024
XRE1824D
XRF1824D
XCM2C024
XCM4C024
X766842
XCKR16
XRE2024D
XCKR25
XCM1A024
XCM2A024
XCM1C048
XCM2C048
X766845
XCM1C110
XCM2C110
X766846
XCM1A120
XCM2A120
X766847
XCM1A230
XCM2A230
102
103
104
105
106
107
110
101
101
101
103
101
101
104
105
110
109
102
109
106
107
103
104
110
103
104
110
106
107
110
106
107
24 Vdc SPDT single relay
R series
77
(3.03 in)
12
(0.47 in)
16.4
(0.65 in)
52
(2.05 in)
77
(3.03 in)
77
(3.03 in)
70
(2.76 in)
16.4
(0.65 in)
70
(2.76 in)
NOTES
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical
(2) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XRFA024D
–
RFA024D (2)
Cat. No. XR_1824D
RE1824D
RF1824D
Cat. No. XR_1024D
RE1024D
RF1024D (2)
24 Vdc ± 10%
15 mA ± 10%
15 ms
5 ms
damping & polarity protection diode
24 Vdc ± 10%
22 mA ± 10%
15 ms
5 ms
damping & polarity protection diode
24 Vdc ± 10%
27 mA ± 10%
15 ms
5 ms
damping & polarity protection diode
SPST(NO) AgSnO2
5 A / 250 Vac
5A
—
SPDT AgSnO2
12 A / 250 Vac
12 A
—
SPDT AgSnO2
16 A / 250 Vac
16 A
—
–10...+50°C
2.5 kVac / 60 s
0,5 kVac / 60 s (between open contact)
IP 00 IEC529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
30 g (1.07 oz)
vertical on rail adjacent without gap
–10...+50°C
2.5 kVac / 60 s
0,5 kVac / 60 s (between open contact)
IP 00 IEC529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
44 g (1.55 oz)
vertical on rail adjacent without gap
–10...+50°C
2.5 kVac / 60 s
0,5 kVac / 60 s (between open contact)
IP 00 IEC529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
44 g (1.55 oz)
vertical on rail adjacent without gap
Cat. No. 8904000
—
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
Cat. No. 8904058
—
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / pollution degree
Reference Standard
Status display
Connection terminals
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
101
24 Vdc SPDT single relay
R series
77
(3.03 in)
16.4
(0.65 in)
93
(3.66 in)
26
(1.02 in)
70
(2.76 in)
75
(2.96 in)
NOTES
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical
(2) Version available upon request
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XRF1012D
–
RF1012D
Cat. No. XRE2024D
RE2024D
–
12 Vdc ± 10%
44 mA ± 10%
15 ms
5 ms
damping & polarity protection diode
24 Vac / dc ± 10%
22 mA ± 10%
15 ms
5 ms
damping & polarity protection diode
SPDT AgSnO2
16 A / 250 Vac
16 A
—
DPDT AgSnO2
8 A / 250 Vac
8A
—
–10...+50°C
2.5 kVac / 60 s
0,5 kVac / 60 s (between open contact)
IP 20 IEC529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
44 g (1.55 oz)
vertical on rail adjacent without gap
–10...+50°C
2.5 kVac / 60 s
0,5 kVac / 60 s (between open contact)
IP 00 IEC529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
76 g (2.68 oz)
vertical on rail adjacent without gap
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / pollution degree
Reference Standard
Status display
Connection terminals
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904032
Cat. No. 8904002
—
—
102
Single relay DC input series
CM
• Pluggable relay
• Mounting on DIN rail or panel through central screw
• Compact dimensions
• Cross and slotted screws
• Screw type jumper available
75
(2.96 in)
16
(0.63 in)
NOTES
68
(2.86 in)
Screw type jumper available
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical.
(2) On request, there are available versions without signalling
and protection circuit; for the order, please add the suffix “Z”
to the item code (for example: XCM1C024Z).
(3) On request, there are available versions with gold-plated
contact; for the order, please add the suffix “U” to the item
code (for example: XCM1C024U).
VERSIONS
Cat. No. XCM1C012
CM1C012
12 Vdc
24 Vdc
48 Vdc
110 Vdc
Cat. No. XCM1C024
Cat. No. XCM1C048
Cat. No. XCM1C110
CM1C024
CM1C048
CM1C0110
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
12 Vdc ±10%
44 mA ±10%
15 ms
5 ms
24 Vdc ±10%
48 Vdc ±10%
22 mA ±10%
12 mA ±10%
15 ms
15 ms
5 ms
5 ms
damping diode (2)
110 Vdc ±10%
11 mA ±10%
15 ms
20 ms
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
SPDT AgSnO2 (3)
12 A / 250 Vac
12 A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category/Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
–10...+50°C
4 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED (2)
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
54 g (1.90 oz)
vertical on rail adjacent without gap or panel with screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904001
Cat. No. 8904008
Cat. No. XCMB16B
—
—
Cat. No. 8904039
Screw type jumper
103
Cat. No. 8904047
DPDT single relay DC input
series CM
• Pluggable relay
• Mounting on DIN rail or panel through central screw
• Compact dimensions
• Cross and slotted screws
• Screw type jumper available
75
(2.96 in)
16
(0.63 in)
75
(2.96 in)
NOTES
Screw type jumper available
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical.
VERSIONS
Cat. No. XCM2C012
CM2C012
12 Vdc
24 Vdc
48 Vdc
110 Vdc
Cat. No. XCM2C024
Cat. No. XCM2C048
Cat. No. XCM2C110
CM2C024
CM2C048
CM2C0110
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
12 Vdc ±10%
44 mA ±10%
15 ms
5 ms
24 Vdc ±10%
22 mA ±10%
15 ms
5 ms
48 Vdc ±10%
24 mA ±10%
15 ms
5 ms
110 Vdc ±10%
11 mA ±10%
15 ms
20 ms
damping diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
DPDT AgSnO2
8 A / 250 Vac
8A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category/Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
–10...+50°C
4 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
67 g (2.37 oz)
vertical on rail adjacent without gap or panel with screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904002
Cat. No. 8904009
Cat. No. XCMB16B
—
—
Cat. No. 8904040
Screw type jumper
104
Cat. No. 8904054
4PDT single relay DC input
series CM
• Pluggable relay
• Mounting on DIN rail or panel through central screw
• Compact dimensions
• Cross and slotted screws
• Screw type jumper available
75
(2.96 in)
27
(1.06 in)
68
(2.86 in)
NOTES
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical
(2) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Cat. No. XCM4C012
CM4C012 (2)
12 Vdc
24 Vdc
48 Vdc
110 Vdc
Cat. No. XCM4C024
Cat. No. XCM1C048
Cat. No. XCM1C110
CM4C024 (2)
—
—
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
12 Vdc ±10%
75 mA ±10%
20 ms
20 ms
24 Vdc ±10%
38 mA ±10%
20 ms
20 ms
damping diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
4PDT AgSnO2
3 A / 250 Vac
3A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category/Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
–10...+50°C
4 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
vertical on rail adjacent without gap or panel with screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904030
Cat. No. XCMB27B
—
—
Cat. No. 8904018
Screw type jumper
105
Single relay AC input series
CM
• Pluggable relay
• Mounting on DIN rail or panel through central screw
• Compact dimensions
• Cross and slotted screws
• Screw type jumper available
75
(2.96 in)
16
(0.63 in)
NOTES
Screw type jumper available
68
(2.86 in)
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical
(2) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Cat. No. XCM1A012
CM1A012 (2)
12 Vdc
24 Vdc
120 Vdc
230 Vdc
Cat. No. XCM1A024
Cat. No. XCM1A120
Cat. No. XCM1A230
CM1A024
CM1A120 (2)
CM1A230
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
12 Vac ±10%
95 mA ±10%
15 ms
10 ms
24 Vac ±10%
48 mA ±10%
15 ms
10 ms
120 Vac ±10%
10.5 mA ±10%
15 ms
10 ms
230 Vac ±10%
6 mA ±10%
15 ms
10 ms
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
SPDT AgSnO2
12 A / 250 Vac
12 A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category/Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
–10...+50°C
4 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
54 g (1.91 oz)
vertical on rail adjacent without gap or panel with screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904048
Cat. No. 8904049
XCMB16B
—
—
Cat. No. 8904016
Screw type jumper
106
Cat. No. 8904050
DPDT single relay AC input
series CM
• Pluggable relay
• Mounting on DIN rail or panel through central screw
• Compact dimensions
• Cross and slotted screws
• Screw type jumper available
75
(2.96 in)
16
(0.63 in)
NOTES
75
(2.96 in)
Screw type jumper available
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be modified without
prior warning. The technical data shown here is to be
considered typical
(2) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
Cat. No. XCM2A012
CM2A012 (2)
12 Vac
24 Vac
120 Vac
230 Vac
Cat. No. XCM2A024
Cat. No. XCM2A120
Cat. No. XCM2A230
CM2A024
CM2A120 (2)
CM2A230
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
12 Vac ±10%
95 mA ±10%
15 ms
10 ms
24 Vac ±10%
48 mA ±10%
15 ms
10 ms
120 Vac ±10%
10.5 mA ±10%
15 ms
10 ms
230 Vac ±10%
6 mA ±10%
15 ms
10 ms
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
DPDT AgSnO2
8 A / 250 Vac
8A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category/Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
–10...+50°C
4 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
III / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
67 g (2.37 oz)
vertical on rail adjacent without gap or panel with screw
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Replacement relay
Screw type jumper
(1)
black
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904055
Cat. No. 8904056
Cat. No. XCMB16B
—
—
Cat. No. 8904017
Screw type jumper
107
Cat. No. 8904057
CK system interface
The series is a collection of interfaces for sensors and actuators, is composed by a wide range of
electromechanical relay and solid state relay modules and passive interfaces in modular housings, which
are only 6 mm wide thus saving valuable space. All products are mounted inside the CK housing, which
is also available for use as a housing for custom. The CK housing can be equipped with six 2.5 mm
spring-clamp terminals and four contacts for the insertion of a PTC parallel connection bridge, which
provides for quick and easy circuit bridging and saves space and harness time.
The product range is currently composed by:
• Single electromechanical relay with 6 A/250 Vac SPDT protected with replaceable fuse, status Led
display on front panel, AC/DC input and positive or negative common on relay coil.
• Double electromechanical relay with 5 A/250 Vac SPST (NO), two status LED displays on front panel,
AC/DC input and positive or negative common on relay coil.
• Single solid state relay for common negative load, 5 A /48 Vdc output current, protected with
replaceable fuse, status LED display on front panel and positive or negative common on input.
• Double solid state relay suitable for 12-24 Vdc 2.5 A loads, status LED display on front panel and
positive or negative common of the input and output as well.
• Diode-holder modules with common anode (CK…AC) or common cathode (CK…CC).
• Lamp and LED test modules.
• Supply connection and distribution modules with LED display.
NO
OK
1
Composition of an interface with the CK System:
• The required modules must be selected and mounted on the DIN rail.
• The common poles of inputs and outputs can be connected in parallel using the fast connection
bridges PTC/CK/42.
• For the connection of inputs and outputs of the relay module interface, we recommend to use the
CKF supply distribution module: it allows to connect and distribute the feeding potential to inputs and
outputs on all adjacent modules; the CKF module can be mounted as first module, or even better, in
the middle position of the interfaces assembly, to divide 50+50% the current on the bridge and to
reduce voltage drop and heating; the CKF- - is available with LED for ON display, and is equipped with
four 2.5 mm / AWG 26 ÷ 14 / 24 A rated spring-clamp terminals - input and output.
• In order to assure the IP XXB protection degree, the last module must be protected and insulated using
the CK/PT end section.
• Main technical data and BLOCK DIAGRAM are printed on one side of each module; for individual
terminal block marking, CNU/8 marking tags are available;CNU/8 marking tags are available in blank
format for pen or plotter marking, or with the Cabur Jet marking printer.
• If the input and output power supply cables of the interface assembly are directly connected to eg. the
first module, two cables must be connected on a single terminal block (feeding wire and load wire)
forcing to reduce the cross-section of each conductor to less than 2,5 mm2; consequently, this means
a current and a reduction of the total number of relay modules that can be fed; the problem can be
solved by using the CKF feeder distribution module as described in the third point.
Easy Bridge system
NO
OK
2
3
4
The fast connection bridge PTC/CK/42 has 42 poles, and a rated current of 32 A; WARNING: the total
current is limited by the rated current of the spring-clamp terminal block (24 A): if a PTC/CK serves 10
relays, a rated current of 2,4 A can be distributed on to each relay.
The use of PTC/CK bridges is simple and cost effective; the following instructions must be followed:
• after having cut the PTC/CK/42-pole bar according to required number of poles, in order to maintain
the IPXXB protection degree the bar must be sheared in proximity of the end poles (see pictures 1
and 2);
• insert the jumper in the slot of the CK terminals (see picture 3);
• by using the blade of a screwdriver, the PTC bridge must be pushed down until it snaps into the
female contacts; in case of long jumpers, the operation shall be started by pushing the bridge in the
middle, then gradually on left / right sides; the jumper will then result completely IPXXB insulated (see
picture 4);
• to remove the jumper, the blade of a screwdriver shall be inserted into the slot provided in the upper
side of the PTC bridge, then lifted up and finally extracted; in case of long jumpers, the bridge shall
be lifted in the middle, then gradually on left / right sides (pictures 5 and 6).
5
6
108
24 Vdc relay modules
CKR series
91
(3.59 in)
• Built-in replaceable contact protection fuse
• AC/DC common negative or positive input
• Status LED display, reverse polarity protection, crow-bar diode
• 6 mm wide
• Plug-in jumper available
6
(0.24 in)
91
(3.59 in)
100
(3.94 in)
6
(0.24 in)
100
(3.94 in)
NOTES
BLOCK DIAGRAM
(1) The contact rated voltage is 250 Vac; max operating voltage of
the contact of the module is 50 Vac-Vdc, limited by the voltage
ratings of the adopted type of fuse, which is rated for ≤50 Vac75 Vdc SELV voltages; WARNING: if used with higher voltage,
it does not guarantee breaking power and thus safety, and IP
protection degree is lowered to IP 00; fuses with higher current
ratings are not allowed and do not protect the contact against
short circuit and overcurrents
(2) Version available upon request.
(3) In order to assure the IP20 protection degree, the last module
must be protected and insulated using the CK/PT end section.
VERSIONS
1 channel
2 channels
Cat. No. XCKR16
CKR16
—
Cat. No. XCKR25
—
CKR25 (2)
24 Vac/dc ± 10%
≤15 mA ± 10% @ 24 Vdc
5 ms
10 ms
bridge rectifier
24 Vac/dc ±10%
≤13 mA ±10% @ 24 Vdc
5 ms
10 ms
bridge rectifier
SPDT AgSnO2
6 A / 250 Vac
30 A
—
2PST (NO) AgSnO2
5 A / 250 Vac
30 A
—
-20…+60°C
3 kVac / 60 s
-20…+60°C
3 kVac / 60 s
IP 20 IEC529, EN60529
II / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² AWG26-14 fixed spring type
polyamide UL94V-0
40 g (1.41 oz)
vertical on rail adjacent without gap
IP 00 IEC529, EN60529
II / 2
IEC 664-1, DIN VDE 0110.1
green LED
2.5 mm² AWG26-14 fixed spring type
polyamide UL94V-0
43 g (1,52 oz)
vertical on rail adjacent without gap
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / pollution degree
Reference Standard
Status display
Connection terminals
Housing material
Approx. weight
Mounting information
Mounting information
ACCESSOIRES DE MONTAGE
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay
Plug-in jumper
Marking tags
End plate
(1)
—
blank
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
Cat. No. PTCCK42 (42 poles)
Cat. No. PTCCK42 (42 poles)
Cat. No. NU0851
Cat. No. NU0851
Cat. No. XCKPT
Cat. No. XCKPT
109
Relay modules AC/DC input
series CWRE
• Pluggable relay
• Status LED display
• 6.2 mm wide
• Plug-in jumper available
89
(3.50 in)
77
(3.03 in)
6.2
(0.24 in)
NOTES
APPLICAZIONI
The height dimension includes 35 mm DIN rail.
(1) Version available upon request; for information call our sales
department, local agent or representative.
(2) Relay model is not binding, they may be modified without prior
warning. The technical data shown here is to be considered
typical.
The CWRE series is suitable for the commutation of signals
and is equipped with a pull-out relay to make the maintenance
operations easy. Furthermore this series offers the possibility to
execute the parallel on both the input and output side by the
means of a proper comb jumper.
VERSIONS
12 Vac/dc
24Vac/dc
48 Vac/dc
115 Vac/dc
230 Vac/dc
Cat. No. X766848
CWRE7-0848 (1)
(1)
BLOCK DIAGRAM
Cat. No. X766842
Cat. No. X766845
Cat. No. X766846
Cat. No. X766847
CWRE7-0842
(1)
CWRE7-0845 (1)
CWRE7-0846
CWRE7-0847
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
12 Vac/dc ±10%
10 mA ±10%
8 ms
5 ms
24 Vac/dc ±10%
7 mA ±10%
8 ms
5 ms
48 Vac/dc ±10%
115 Vac/dc ±10%
5 mA ±10%
4 mA ±10%
7 ms
8 ms
7 ms
13 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal current (resistive load)
Current breaking power
Current of the fuse max.
SPDT AgSnO2 (3)
6 A / 250 Vac ; 6 A / 30 Vdc
DC 13: 24 V / 1A; 115V / 200 mA; 230 V / 100 mA
—
GENERAL TECHNICAL DATA
Operating temperature
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / pollution degree
Reference Standard
Status display
Connection terminals
Housing material
Approx. weight
Mounting information
–40...+70°C
4 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
III / 2
IEC 664.1, DIN VDE 0110.1
green LED
2.5 mm² fixed screw type AWG26-14
UL94V-0 plastic material
35 g (1.23 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Replacement relay
Plug-in jumper
(2)
black
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904027
—
—
CWBK7-0813 (Cat. No. X766813) (20 poli)
110
230 Vac/dc ±10%
4 mA ±10%
8 ms
13 ms
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Number of
relays
Input rated voltage
Output type / no. of
contacts
Rated current
Notes
Type
Cat. No.
Page
4
8
16
4
8
16
4
8
16
4
8
16
4
8
16
8
4
8
16
4
8
16
4
4
8
8
4
4
24 Vdc
24 Vdc
24 Vdc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vdc
24 Vdc
24 Vdc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
110 Vdc/120 Vac
110 Vdc/120 Vac
110 Vdc/120 Vac
230 Vac
230 Vac
230 Vac
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
24 Vac/dc
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
DPDT
DPDT
DPDT
DPDT
DPDT
DPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPDT
SPST(NO)
SPST(NO)
DPDT
DPDT
12 A
12 A
12 A
12 A
12 A
12 A
12 A
12 A
12 A
8A
8A
8A
8A
8A
8A
12 A
10 A
10 A
10 A
10 A
10 A
10 A
8A
8A
8A
8A
8A
8A
(1) (4)
(1) (4)
(1) (4)
(1) (6)
(1) (6)
(1) (6)
(1) (6) (8)
(1) (6) (8)
(1) (6) (8)
(1) (4)
(1) (4)
(1) (4)
(1) (6)
(1) (6)
(1) (6)
(1) (6) (9) (10)
(1) (6)
(1) (6)
(1) (6)
(1) (6)
(1) (6)
(1) (6)
(2) (6)
(1) (6)
(1) (6)
(2) (6)
(2) (6)
(1) (6)
R41E24
R81E24
R161E24
R41EAD
R81EAD
R161EAD
R41U24F
R81U24F
R161U24F
R42E24
R82E24
R162E24
R42EAD
R82EAD
R162EAD
RMP081CM
R41E11A
R81E11A
R161E11A
R41E22A
R81E22A
R161E22A
CR4-1
CRE4-1
CRE8-1
CR8-1
CR4-2SC
CRE4-2SC
XR041E24
XR081E24
XR161E24
XR041EAD
XR081EAD
XR161EAD
XR041U24F
XR081U24F
XR161U24F
XR042E24
XR082E24
XR162E24
XR042EAD
XR082EAD
XR162EAD
XRMP081CM
XR041E1A
XR081E1A
XR161E1A
XR041E2A
XR081E2A
XR161E2A
XCR41
XCRE41
XCRE81
XCR81
XCR42SC
XCRE42SC
113
113
113
114
114
114
115
115
115
116
116
116
118
118
118
119
120
120
120
121
121
121
122
122
122
122
123
123
Note
(1)
(2)
(3)
(4)
(5)
version with pluggable relay
version with fixed relay
with socket but without relay
negative common, positive command
positive common, negative command
(6)
(7)
(8)
(9)
(10)
111
universal control voltage, negative DC command, positive DC, AC
with connector input command
with protection fuse on the relay contact
with test push button
with test switch
24 Vdc SPDT relay
modules negative
common
• DC control voltage
• Negative control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
93
(3.66 in)
250
(9.85 in)
75
(2.96 in)
75
(2.96 in)
NOTES
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical
VERSIONS
4 relay module
8 relay module
16 relay module
Cat. No. XR041E24
R41E24
Cat. No. XR081E24
4 relay module
Cat. No. XR161E24
R81E24
R161E24
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
22 mA ± 10%
15 ms
5 ms
damping and polarity protection diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
81
SPDT AgSnO2
12 A / 250 Vac
12 A
—
84 82
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
188 g (6.63 oz)
342 g (12.06 oz)
657 g (23,17 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
112
24 Vdc SPDT relay
modules positive
common
• DC control voltage
• Positive control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
VERSIONS
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
NOTES
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical
93
(3.66 in)
75
(2.96 in)
BLOCK DIAGRAM
Article available until sell-out
XR041E24P will be replaced by XR041EAD
XR081E24P will be replaced by XR081EAD
XR161E24P will be replaced by XR161EAD
Cat. No. XR041E24P
R41E24P
Cat. No. XR081E24P
Cat. No. XR161E24P
4 relay module
R81E24P
R161E24P
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
22 mA ± 10%
15 ms
5 ms
damping and polarity protection diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
SPDT AgSnO2
12 A / 250 Vac
12 A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
188 g (6.63 oz)
342 g (12.06 oz)
657 g (23,17 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
113
24 Vac/dc SPDT relay
modules universal
control voltage
• DC and AC control voltage
• Positive or negative control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
VERSIONS
75
(2.96 in)
NOTES
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical
(2) Version available upon request.
93
(3.66 in)
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
A1 = ~ A2 = ~
Cat. No. XR041EAD
R41EAD
negative common
positive common
AC power supply
Cat. No. XR081EAD
Cat. No. XR161EAD
4 relay module
R81EAD
R161EAD
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
22 mA ± 10%
15 ms
5 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
SPDT AgSnO2
12 A / 250 Vac
12 A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
192 g (6.76 oz)
345 g (12.18 oz)
688 g (24.29 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
114
24 Vac/dc SPDT relay
modules universal control
voltage with fuse
• DC and AC control voltage
• Positive or negative control voltage
• Status LED display
• Pluggable relay
• Output contact with protection fuse
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
VERSIONS
75
(2.96 in)
NOTES
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
The height dimension includes 35 mm DIN rail. (1)
Relay model is not binding, they may be modified
without prior warning. The technical data shown
here is to be considered typical. (2) The interface
is supplied without a fuse and the screw plug
of the fuse-holder is provided in a bag inside
the packaging. The fuse must be dimensioned
according to load. The max. value of 6.3 A is
referred to EN60127-complying fuses and the
homologation rated current of the fuseholder.
Fuses of a higher value may damage the fuseholder and module.
93
(3.66 in)
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
A1 = ~ A2 = ~
Cat. No. XR041U24F
R41U24F
negative common
positive common
AC power supply
Cat. No. XR081U24F
Cat. No. XR161U24F
4 relay module
R81U24F
R161U24F
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
22 mA ± 10%
15 ms
10 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
SPDT AgSnO2 per 4 relé
12 A / 250 Vac
12 A
6,3 A (2)
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
210 g (7.41 oz)
326 g (11.51 oz)
770 g (27.18 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
115
24 Vdc DPDT relay
modules negative
common
• DC control voltage
• Negative control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
250
(9.85 in)
75
(2.96 in)
75
(2.96 in)
NOTES
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
VERSIONS
4 relay module
8 relay module
16 relay module
Cat. No. XR042E24
R42E24
Cat. No. XR082E24
Cat. No. XR162E24
4 relay module
R82E24
R162E24
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
22 mA ± 10%
15 ms
10 ms
damping and polarity protection diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
DPDT AgNi
8 A / 250 Vac
8A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
225 g (7.94 oz)
419 g (14.78 oz)
811 g (28.60 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904002
—
—
—
116
24 Vdc DPDT relay
modules positive
common
• DC control voltage
• Positive control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
VERSIONS
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
75
(2.96 in)
NOTES
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
93
(3.66 in)
BLOCK DIAGRAM
Article available until sell-out
XR042E24P will be replaced by XR042EAD
XR082E24P will be replaced by XR082EAD
XR162E24P will be replaced by XR162EAD
Cat. No. XR042E24P
R42E24P
Cat. No. XR082E24P
Cat. No. XR162E24P
4 relay module
R82E24P
R162E24P
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
22 mA ± 10%
15 ms
5 ms
damping and polarity protection diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
DPDT AgNi
8 A / 250 Vac
8A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
225 g (7.94 oz)
419 g (14.78 oz)
811 g (28.60 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904002
—
—
—
117
24 Vac/dc DPDT relay
modules universal
control voltage
• DC and AC control voltage
• Positive or negative control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
VERSIONS
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
75
(2.96 in)
NOTES
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
(2) Version available upon request.
93
(3.66 in)
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
A1 = ~ A2 = ~
Cat. No. XR042EAD
R42EAD
negative common
positive common
AC power supply
Cat. No. XR082EAD
Cat. No. XR162EAD
4 relay module
R82EAD
R162EAD
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
22 mA ± 10%
15 ms
5 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
DPDT AgNi
8 A / 250 Vac
8A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
227 g (8.01 oz)
427 g (15.07 oz)
835 g (29.48 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/
TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904002
—
—
—
118
24 Vac/dc relay
modules universal
control voltage with
test push button
93
(3.66 in)
• DC control voltage
• Positive or negative control voltage
• Status LED display
• Pluggable relay
• Test with push button and micro switch
136
(5.35 in)
75
(2.96 in)
NOTES
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
(2) They replace XRP08124 and XRD08124
models.
VERSIONS
Con pulsante e dip switch
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
A1 = ~ A2 = ~
negative common
positive common
AC power supply
Cat. No. XRMP081CM (2)
RMPO81CM
P
D
IG
=
=
=
test button
dip-switch
master switch (disable the push button and dip-switch)
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
22 mA ± 10%
15 ms
5 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
SPDT AgSnO2 per 8 relé
12 A / 250 Vac
12 A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
350 g (12.36 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
119
This series of products allows piloting with alternating and direct current, in which
case only positive control is possible. We also recommend cutting JP jumpers if
piloting takes place via low-current devices (e.g. proximity sensors).
On both versions it is possible the temporary turn on of the relay by pushing the
relative button.
On model RD08124 it is possible to switch on the relays permanently with a DipSwitch.
IG
P
D (not illustrated)
110…120 Vac/dc SPDT
relay modules universal
control voltage
• DC and AC control voltage
• Positive or negative control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
70
(2.76 in)
93
(3.66 in)
75
(2.96 in)
75
(2.96 in)
VERSIONS
75
(2.96 in)
NOTES
4 relay module
8 relay module
16 relay module
250
(9.85 in)
137
(5.40 in)
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
93
(3.66 in)
BLOCK DIAGRAM
Article available until sell-out
With 110 Vdc rated voltage:
- replace XR041E11A with no.4 XCM1C110 and no.1 XCMB16B
- replace XR081E11A with no.8 XCM1C110 and no.1 XCMB16B
- replace XR161E11A with no.16 XCM1C110 and no.2 XCMB16B
With 120 Vac rated voltage:
- replace XR041E11A with no.4 XCM1A120 and no.1 XCMB16B
- replace XR081E11A with no.8 XCM1A120 and no.1 XCMB16B
- replace XR161E11A with no.16 XCM1A120 and no.2 XCMB16B
Cat. No. XR041E1A
R41E11A
Cat. No. XR081E1A
4 relay module
Cat. No. XR161E1A
R81E11A
R161E11A
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
110 Vdc / 120 Vac ± 10%
11 mA ± 10%
7 ms
3 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
SPDT AgNi
12 A / 250 Vac
12 A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
192 g (6.76 oz)
345 g (12.18 oz)
688 g (24.29 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904047
—
—
—
120
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
A1 = ~ A2 = ~
negative common
positive common
AC power supply
230 Vac SPDT relay
modules
• AC control voltage
• Status LED display
• Pluggable relay
93
(3.66 in)
93
(3.66 in)
137
(5.40 in)
70
(2.76 in)
75
(2.96 in)
VERSIONS
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
75
(2.96 in)
NOTES
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
93
(3.66 in)
BLOCK DIAGRAM
Article available until sell-out
replace XR041E22A with no.4 XCM1A230 and no.1 XCMB16B
replace XR081E22A with no.8 XCM1A230 and no.1 XCMB16B
replace XR161E22A with no.16 XCM1A230 and no.2 XCMB16B
Cat. No. XR041E2A
R41E22A
Cat. No. XR081E2A
Cat. No. XR161E2A
4 relay module
R81E22A
R161E22A
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
230 Vac ± 10%
10 mA ± 10%
7 ms
2 ms
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
SPDT AgSnO2
12 A / 250 Vac
12 A
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
192 g (6.76 oz)
345 g (12.18 oz)
688 g (24.29 oz)
vertical on rail adjacent without gap
16 relay module
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904050
—
—
—
121
Super compact 24
Vac/dc relay modules
universal control
voltage
108
(4.26 in)
• 3 kV I/O isolation
• 1 kV isolation between output contact
• Fast connection whit pluggable terminals
• DC and AC control voltage
• Positive or negative control voltage
NOTES
119
(4.69 in)
A
108
(4.26 in)
119
(4.69 in)
A
A = 22.5 mm (0.88 in) CR version, 35 mm (1.38 in) CRE version
BLOCK DIAGRAM
A = 22.5 mm (0.88 in) CR version, 35 mm (1.38 in) CRE version
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical
data shown here is to be considered typical.
CR4-1 and CRE4-1: relay module with SPDT, inputs
and outputs with pluggable terminals.
CR8-1 and CR8E-1: 8 relay module with SPST (NO),
inputs and outputs with pluggable terminals.
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCRE41
CRE4-1
Cat. No. XCR4
Cat. No. XCRE81
CRE8-1
Cat. No. XCR81
CR8-1
CR4-1
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
16 mA ± 10%
7 ms
3 ms
damping diode and bridge rectifier
24 Vac/dc ± 10%
16 mA ± 10%
7 ms
3 ms
damping diode and bridge rectifier
SPDT AgNiO per 4 relé
8 A / 250 Vac
2000 VA
—
SPST(NO) per 8 relay
8 A / 250 Vac
2000 VA
—
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
143 g (5.05 oz) (180 g [6.35 oz] pluggable version)
vertical on rail adjacent without gap
-10...+50°C
3 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
199 g (7.02 oz) (250 g [8.83 oz] pluggable version)
vertical on rail adjacent without gap
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904042
—
—
—
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904042
—
—
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
122
Super compact 24
Vac/dc relay modules
universal control
voltage
108
(4.26 in)
• 3 kV I/O isolation
• 1 kV isolation between output contact
• Fast connection whit pluggable terminals
• DC and AC control voltage
• Positive or negative control voltage
NOTES
119
(4.69 in)
A
A = 22.5 mm (0.88 in) CR version, 35 mm (1.38 in) CRE version
BLOCK DIAGRAM
The height dimension includes 35 mm DIN rail.
(1) Relay model is not binding, they may be
modified without prior warning. The technical data
shown here is to be considered typical
(2) Version available upon request; for information
call our sales department, local agent or representative
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCRE42SC
CRE4-2SC (2)
Cat. No. XCR42SC
CR4-2SC (2)
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
25 mA ± 10%
7 ms
2 ms
damping diode and bridge rectifier
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
DPDT AgNi per 4 relé
8 A / 250 Vac
2000 VA
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
137 g (180 g pluggable version)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904052
—
—
—
123
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Input modules
Number of channels
Connection type
Notes
Type
Cat. No.
Page
8 without isolation
12 Vdc
(1) (4)
IF16S7
XIF16S7
125
8 without isolation
12 Vdc
(1) (3)
IF16LS7
XIF16LS7
125
32 without isolation
12 Vdc
(1) (4)
IF416S7
XIF416S7
125
32 without isolation
12 Vdc
(1) (3)
IF416LS7
XIF416LS7
125
Cat. No.
Page
XCR83
XCRE83
XRFE8124
XRFE8224
XRFE16124
XRFE16224
126
126
126
127
128
128
Output modules
Number of
channels
8
8
8
8
16
16
Input voltage
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
24 Vdc
Output
type / no. of contacts
rated current
SPST(NO)
SPST(NO)
SPDT
DPDT
SPDT
DPDT
8A
8A
10 A
5A
10 A
5A
Notes
(1) (3) (5)
(1) (3) (5)
(1) (3) (5)
(1) (3) (5)
(2) (3) (5)
(2) (3) (5)
Notes
(1) suitable for PLC Siemens S7 series
(2) suitable for PLC Telemecanique
(3) with LED to display the status
(4) without LED to display the status
(5) version with pluggable relay
124
Type
CR8-3
CRE8-3
RFE8124
RFE8224
RFE16124
RFE16224
PLC S7 300 & S7 400
Interface modules
• I/O modules
• With or without status LED display
• Fast connection
93
(3.66 in)
112
(4.41 in)
50
(1.97 in)
Item available till sell-out
78
(3.07 in)
NOTES
93
(3.66 in)
BLOCK DIAGRAM
78
(3.07 in)
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
(2) Version available upon request; for information
call our sales department, local agent or representative
VERSIONS
With LED to display the status
Without LED to display the status
Cat. No. XIF16S7
—
IF16S7 (2)
Cat. No. XIF416LS7
IF416LS7 (2)
Cat. No. XIF416S7
IF416S7 (2)
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
5 mA ± 10% (only with “Status LED” version)
—
—
—
24 Vdc ± 10%
5 mA ± 10% (only with “Status LED” version)
—
—
—
8 channels without isolation
—
—
—
4 x 8 channels without isolation
—
—
—
-10...+50°C
—
—
IP 00 IEC529, EN60529
,, / 2
IEC 664-1
LED (solo su IF16LS7)
flat cable 16 poles male and 2.5 mm² fixed screw type
polyamide UL94V-0
—
—
-10...+50°C
—
—
IP 00 IEC529, EN60529
,, / 2
IEC 664-1
LED (solo su IF416LS7)
flat cable 16 poles male and 2.5 mm² fixed screw type
polyamide UL94V-0
—
—
PR/3/AC, PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
PR/3/AC, PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
—
—
—
—
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminals
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
x
125
PLC S7 300 & S7 400
Interface modules
• Very compact dimension in CR version
• Fast connection
• Pluggable relay
• Status LED display
93
(3.66 in)
108
(4.26 in)
137
(5.40 in)
119
(4.69 in)
A
A = 22.5 mm (0.88 in) CR version, 35 mm (1.38 in) CRE version
NOTES
BLOCK DIAGRAM
75
(2.96 in)
Item available until sell-out
will be replaced by XR081E24
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
(2) Version available upon request.
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCRE83
CRE8-3
Cat. No. XCR83
Cat. No. XRFE8124
RFE8124
—
CR8-3
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vac/dc ± 10%
16 mA ± 10%
15 ms
5 ms
damping diode and bridge rectifier
24 Vac/dc ± 10%
20 mA ± 10%
15 ms
10 ms
damping diode and bridge rectifier
SPST(NO) per 8 relay
10 A / 250 Vac
2000 VA
—
SPDT AgNiO per 8 relé
10 A / 250 Vac
10 A
—
-10...+50°C
3 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 20 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
flat cable 16 poles male
UL94V-0 plastic material
199 g (7.02 oz)
vertical on rail adjacent without gap
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
flat cable 16 poles male and 2.5 mm² fixed screw type
UL94V-0 plastic material
342 g (12.07 oz)
vertical on rail adjacent without gap
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Cat. No. 8904042
—
—
—
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
126
PLC S7 300 & S7 400
Interface modules
• DC control voltage
• Negative control voltage
• Status LED display
• Pluggable relay
• Fast connection
93 (3.66 in)
137
(5.40 in)
75 (2.96 in)
NOTES
Item available until sell-out
will be replaced by XR082E24
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
(2) Version available upon request.
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XRFE8224
RFE8224
—
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
20 mA ± 10%
15 ms
5 ms
damping and polarity protection diode
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
DPDT AgNiO per 8 relé
5 A / 250 Vac
5A
—
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
flat cable 16 poles male and 2.5 mm² fixed screw type
UL94V-0 plastic material
419 g (14.79 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904002
—
—
—
127
Telemecanique
PLC interface
modules
93
(3.66 in)
• DC control voltage
• Negative control voltage
• Status LED display
• Pluggable relay
• Fast connection
250
(9.85 in)
250
(9.85 in)
75
(2.96 in)
Item available until sell-out
will be replaced by XR161E24
NOTES
93
(3.66 in)
BLOCK DIAGRAM
Item available until sell-out
will be replaced by XR162E24
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XRFE16124
RFE16124
Cat. No. XRFE16224
RFE16224
—
—
INPUT TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Turn ON time
Turn OFF time
Protection circuit
24 Vdc ± 10%
20 mA ± 10%
15 ms
5 ms
damping and polarity protection diode
24 Vdc ± 10%
20 mA ± 10%
15 ms
5 ms
damping and polarity protection diode
SPDT AgNiO per 16 relé
10 A / 250 Vac
10 A
—
DPDT AgNiO per 16 relé
5 A / 250 Vac
5A
—
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
flat cable 16 poles male and 2.5 mm² fixed screw type
UL94V-0 plastic material
657 g (23.19 oz)
vertical on rail adjacent without gap
-10...+50°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
flat cable 16 poles male and 2.5 mm² fixed screw type
UL94V-0 plastic material
811 g (28.63 oz)
vertical on rail adjacent without gap
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904001
—
—
—
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904002
—
—
—
OUTPUT TECHNICAL DATA
Type and number of contacts
Nominal load (resistive)
Current breaking power
Current of the fuse max.
GENERAL TECHNICAL DATA
Operating temperature range
Coil/contact isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
128
75
(2.96 in)
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Input modules
Number of
channels
Input voltage
Applicable load
Voltage
Current
Notes
Type
Cat. No.
Page
1
5...24 Vdc
5…48 Vdc
3A
(2)
O332060
XO332060
130
1
5…24 Vdc
5…48 Vdc
500 mA
(2)
CWOT 6-2082
X766082
136
1
12…24 Vdc
5…48 Vdc
500 mA
(2)
CWOT 6-2083
X766083
135
1
12…24 Vdc
5…48 Vdc
5A
(1)
CM1S024E
XCM1S024E
131
1
24 Vdc
5…48 Vdc
2A
(1)
CM1S024
XCM1S024
131
1
5…12 Vdc
5…24 Vdc
5A
(2) (4)
CKS15NA
XCKS15NA
133
1
5…24 Vdc
5…24 Vdc
30 mA
(2)
CKS1S
XCKS1S
136
1
24 Vdc
5…24 Vdc
5A
(2) (4)
CKS15NB
XCKS15NB
133
1
5...24 Vdc
5...24 Vdc
5A
(2) (5)
CKS15E
XCKS15E
134
1
12…24 Vdc
12...240 Vac
3A
(1)
CM1T024E
XCM1T024E
132
1
5...24 Vdc
24...240 Vac
4A
(2)
O332240
XO332240
130
1
24 Vdc
48...240 Vac
2A
(1)
CM1T024
XCM1T024
132
2
12…24 Vdc
12…24 Vdc
2 x 2.5 A
(2)
CKS22
XCKS22
134
4
24 Vdc
5…48 Vdc
2A
(1) (3) (4)
R41S24F
XR041S24F
139
4
24 Vdc
5…48 Vdc
2A
(1) (3)
R42S24
XR042S24
137
4
24 Vdc
48...240 Vac
2A
(1) (3)
R42T24
XR042T24
138
8
24 Vdc
5…48 Vdc
2A
(1) (3) (4)
R81S24F
XR081S24F
139
8
24 Vdc
5…48 Vdc
2A
(1) (3)
R82S24
XR082S24
137
8
24 Vdc
48...240 Vac
2A
(1) (3)
R82T24
XR082T24
138
8
5...24 Vdc
12...24 Vdc
8 x 2.5 A
(2) (5)
COP082
XCOP082
140
16
24 Vdc
5…48 Vdc
2A
(1) (3) (4)
R161S24F
XR161S24F
139
16
24 Vdc
5…48 Vdc
2A
(1) (3)
R162S24
XR162S24
137
16
24 Vdc
48...240 Vac
2A
(1) (3)
R162T24
XR162T24
138
Notes
(1) version with pluggable relay
(2) version with fixed relay
(3) universal control voltage, negative/positive DC command
(4) output contact with protection fuse
(5) electronic output protection
129
Solid state 5...24 Vdc
single relay
• Fixed relay
• Compact dimensions
• Status LED display
77
(3.03 in)
12
(0.47 in)
NOTES
54
(2.13 in)
77
(3.03 in)
12
(0.47 in)
BLOCK DIAGRAM
54
(2.13 in)
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
VERSIONS
Cat. No. XO332060
Pluggable relay
Fixed relay
Cat. No. XO332240
—
—
O332240
O332060
INPUT TECHNICAL DATA
4…30 Vdc
> 3 Vdc
< 1 Vdc
< 35 mA
100 Hz max
2.5 mm² fixed screw type
4…30 Vdc
> 3 Vdc
< 1 Vdc
< 35 mA
100 Hz max
2.5 mm² fixed screw type
5…60 Vdc
3 A a 20°C (see chart)
4 A a 20°C (5 A / 5 s - 25 A / 10 ms)
1 mA
—
diode
2.5 mm² fixed screw type
24…240 Vac (zero crossing)
4 A a 20°C (see chart)
5 A a 20°C (6 A / 5 s - 25 A / 10 ms)
5 mA
10 ms max
RC filter
2.5 mm² fixed screw type
-20…-60°C (see chart)
4 kVac / 60 s
IP 00 IEC529, EN60529
IEC 664-1, DIN VDE 0110.1
III
OPTO22
LED
Polyamide UL94V-0
36 g (1.27 oz)
vertical on rail, allow 4 mm spacing between adjacent components
-20…-60°C (see chart)
4 kVac / 60 s
IP 00 IEC529, EN60529
IEC 664-1, DIN VDE 0110.1
III
OPTO22
LED
Polyamide UL94V-0
36 g (1.27 oz)
vertical on rail, allow 4 mm spacing between adjacent components
PR/3/AC, PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
—
—
—
PR/3/AC, PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
—
—
—
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current
Switching frequency
Connection terminals
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Connection terminals
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation (coil/contact)
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Modello del relé (1)
Status display
Housing material
Approx. weight
Mounting information
4
4
3
3
Iout (AC)
Iout (DC)
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
red
white
blue
2
1
20 30 40 50 60 70 80 90 100
Ambient Temperature (°C)
130
2
1
20 30 40 50 60 70 80 90 100
Ambient Temperature (°C)
Solid state 12-24 Vdc
single relay
• Low cost
• For DC load (S version)
• Pluggable relay
• Screw type jumper available
• Status LED display
75
(2.96 in)
16
(0.63 in)
NOTES
75
(2.96 in)
16
(0.63 in)
68
(2.68 in)
BLOCK DIAGRAM
68
(2.68 in)
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
(2)Version available upon request; for information call
our sales department, local agent or representative
This series can be mounted without any spacing
between adjacent components.
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCM1S024
CM1S024 (2)
Cat. No. XCM1S024E
CM1S024E (2)
—
—
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current (1 channel)
Switching frequency
Connection terminals
24 Vdc (19.2…28.8 Vdc)
> 19.2 Vdc
< 1 Vdc
< 20 mA
100 Hz max
2.5 mm² fixed screw type
12-24 Vdc (10…32 Vdc)
> 10 Vdc
< 9 Vdc
< 13 mA
100 Hz max
2.5 mm² fixed screw type
3…50 Vdc
2 A a 40°C
8 A /10 ms
0.1 mA
100 μs / 1 ms
diodo
2.5 mm² fixed screw type
0…35 Vdc
5 A @ 60°C
120 A (peak)
10 μA
100 μs / 1 ms
diodo
2.5 mm² fixed screw type
-20...+80°C over 40°C apply a derating of 0.04A/°C
2.5 kVac / 60 s
IP 00 IEC529, EN60529
IEC 664-1, DIN VDE 0110.1
III
HF JGX-40F
LED
Polyamide UL94V-0
—
vertical on rail adjacent without gap
--20...+80°C over 60°C apply a derating of 0,05A/°C
2.5 kVac / 60 s
IP 00 IEC529, EN60529
IEC 664-1, DIN VDE 0110.1
III
ELCO SSR91-60B
LED
Polyamide UL94V-0
—
vertical on rail adjacent without gap
PR/3/AC, PR/3/AS
—
Cat. No. 8904404
Cat. No. XCMB16B
—
—
PR/3/AC, PR/3/AS
—
Cat. No. 8904402
Cat. No. XCMB16B
—
—
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Connection terminals
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation (coil/contact)
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Modello del relé (1)
Status display
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
black
white
blue
Screw type jumper
131
Solid state 12-24 Vdc
single relay
• Low cost
• For AC load (T version)
• Pluggable relay
• Screw type jumper available
• Status LED display
75
(2.96 in)
16
(0.63 in)
NOTES
68
(2.68 in)
BLOCK DIAGRAM
75
(2.96 in)
16
(0.63 in)
68
(2.68 in)
BLOCK DIAGRAM
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here
is to be considered typical.
(2)Version available upon request; for information call
our sales department, local agent or representative
This series can be mounted without any spacing
between adjacent components.
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCM1T024
CM1T024 (2)
Cat. No. XCM1T024E
CM1T024E (2)
—
—
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current (1 channel)
Switching frequency
Connection terminals
24 Vdc (19.2…28.8 Vdc)
> 19.2 Vdc
< 1 Vdc
< 20 mA
100 Hz max
2.5 mm² fixed screw type
12-24 Vdc (10…32 Vdc)
> 10 Vdc
< 9 Vdc
< 13 mA
100 Hz max
2.5 mm² fixed screw type
48…280 Vac (zero crossing)
3 A a 40°C
120 A /10 ms
5 mA
1/2 cycle + 1 ms
—
2.5 mm² fixed screw type
12...275 Vac (zero crossing)
3,5A @ 40°C / 3 A @ 60°C
120 A (peak)
1 mA
10 ms / 10 ms max.
—
2.5 mm² fixed screw type
-20...+80°C over 40°C apply a derating of 0.05A/°C
2.5 kVac / 60 s
IP 00 IEC529, EN60529
IEC 664-1, DIN VDE 0110.1
III
HF JGX-40F
LED
Polyamide UL94V-0
—
vertical on rail adjacent without gap
-20...+80°C over 40°C apply a derating of 0,025A/°C
2.5 kVac / 60 s
IP 00 IEC529, EN60529
IEC 664-1, DIN VDE 0110.1
III
ELCO SSR91-60B
LED
Polyamide UL94V-0
—
vertical on rail adjacent without gap
PR/3/AC, PR/3/AS
—
Cat. No. 8904405
Cat. No. XCMB16B
—
—
PR/3/AC, PR/3/AS
—
Cat. No. 8904403
Cat. No. XCMB16B
—
—
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Connection terminals
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation (coil/contact)
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Modello del relé (1)
Status display
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
black
white
blue
Screw type jumper
132
Solid state 12-24 Vdc
single relay with fuse
• 5 A / 24 Vdc rated current
• Common negative or positive input
• Overload, short-circuit protected output with replaceable
fuse
• Status LED display, reverse polarity protection
• 6 mm wide
• Plug-in jumper available
91
(3.59 in)
6
(0.24 in)
91
(3.59 in)
100
(3.94 in)
6
(0.24 in)
100
(3.94 in)
NOTES
BLOCK DIAGRAM
BLOCK DIAGRAM
(1) The fast blow-out fuse is calibrated to protect
the output stage of the module and it is connected
in series to the positive pole; it is possible to replace
the fuse with lower rated current values, selected to
protect also the load and its wires; a fuse having a
current rating higher than 5 A does not protect the
output against short circuit and overloads.
(2) In order to assure the IP20 protection degree, the
last module must be protected and insulated using
the CK/PT end section.
(3) Version available upon request; for information call
our sales department, local agent or representative
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCKS15NA
Cat. No. XCKS15NB
—
—
CKS15NB
CKS15NA (3)
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current
4.5…12 Vdc
≥4.5 Vdc
≤4 Vdc
≤5 mA @ 12 Vdc
19…30 Vdc
≥ 20 Vdc
≤18 Vdc
≤ 5 mA @ 24 Vdc
5.2…60 Vdc, max. 100 V (peak)
5 A / 24 Vdc @ 25°C
7.5 A / 1 s, 25 A / 50 ms
5.2 V / 10 mA
25 μA @ 60 Vdc between 13 and 14
3 kVac / 60 s
F5A
5.2…60 Vdc, max. 100 V (peak)
5 A / 24 Vdc @ 25°C
7.5 A / 1 s, 25 A / 50 ms
5.2 V / 10 mA
25 μA @ 60 Vdc between 13 and 14
3 kVac / 60 s
F5A
-20…+60°C
3 kVac / 60 s
400 Hz max.
IP20 IEC529 EN60529
IEC 664-1, EN50081-1
2
II
2.5 mm² (AWG 14), AWG26-14 spring type
Polyamide UL94V-0
32 g (1.13 oz)
vertical on rail adjacent without gap
-20…+60°C
3 kVac / 60 s
400 Hz max.
IP20 IEC529 EN60529
IEC 664-1, EN50081-1
2
II
2.5 mm² (AWG 14), AWG26-14 spring type
Polyamide UL94V-0
32 g (1.13 oz)
vertical on rail adjacent without gap
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
Cat. No. PTCCK42 (42 poles)
Cat. No. NU0851
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
Cat. No. PTCCK42 (42 poles)
Cat. No. NU0851
Cat. No. XCKPT
Cat. No. XCKPT
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Min. applicable load
Leakage current 0 signal
Isolation between open contacts
Protection fuse (1)
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation
Max. switching frequency
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Connection terminals
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7,5
Mounting rail type according to IEC60715/G32
Replacement relay
(1)
Plug-in jumper
—
Marking tags
blank
End plate
133
Solid state 12-24 Vdc
single relay with electronic
• Electronic protection from short circuit, overload,
overtemperature
• Input and output status LED
• Output extravoltage suppressor diode
• Extralow current absorbing
• Plug-in jumper available
91
(3.59 in)
91
(3.59 in)
6
(0.24 in)
100
(3.94 in)
12
(0.48 in)
100
(3.94 in)
NOTES
BLOCK DIAGRAM
BLOCK DIAGRAM
(1) Maximum output current of each channel
depends on surrounding air temperature, on the
number of output contemporarily active and on the
current flowing through them; the given value is
measured with 4 active outputs and 4 not active
(2) All outputs are overcurrent and overtemperature;
when ovd or ovt protections cuts off the output
current, the output display led turns off or reduces
its light depending on ovd degree; the output turns on
automatically when the ovd or ovt are removed.
(3) Version available upon request; for information call
our sales department, local agent or representative
VERSIONS
Pluggable relay
Fixed relay
Cat. No. XCKS15E
Cat. No. XCKS22
—
—
CKS22 (3)
CKS15E
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current
Input channels
5...24 Vdc (4.2…32 Vdc)
> 3.5 Vdc
< 3.5 Vdc
≤ 5 mA @ 24 Vdc
1
12…24 Vdc (range 8…33 Vdc)
≥ 12 Vdc
≤ 11.7 Vdc
≤ 5 mA @ 24 Vdc
2 with common negative
5...24 Vdc (5…32 Vdc)
5 A / 24 Vdc @ 45°C (1)
7.5 A / 60 s, 2 5A / 50 ms peak (1)
5.2 V / 100 mA
200 Hz max.
< 25 μA @ 24 Vdc
—
electronic from overload, overtemperature (2)
12…24 Vdc (range 5…33 Vdc)
2 x 2.5 A / 24 Vdc @ 45°C
4.4 A
10 mA
—
1 mA @ 24 Vdc
3 kVac / 60 s
—
-20 ... +60°C (with therml protection) (2)
3 kVac / 60 s
—
IP20 IEC529 EN60529
IEC 664-1, EN50081-1
2
II
2.5 mm² AWG26-14 fixed spring type
Polyamide UL94V-0
30 g (1.06 oz)
vertical on rail adjacent without gap
-20 ... +60°C (with therml protection) (2)
3 kVac / 60 s
1 kHz (Ton <500 ms / Toff <500 ms)
IP20 IEC529 EN60529
IEC 664-1, EN50081-1
2
II
2.5 mm² AWG26-14 fixed spring type
Polyamide UL94V-0
32 g (1.13 oz)
vertical on rail adjacent without gap
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
Cat. No. PTCCK42 (42 poles)
Cat. No. NU0851
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
Cat. No. PTCCK42 (42 poles)
Cat. No. NU0851
Cat. No. XCKPT
Cat. No. XCKPT
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Min. applicable load
Max. switching frequency
Leakage current 0 signal
Isolation between open contacts
Protection
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation
Max. switching frequency
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Connection terminals
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7,5
Mounting rail type according to IEC60715/G32
Replacement relay
(1)
Plug-in jumper
—
Marking tags
blank
End plate
134
Solid state 12-24 Vdc
single relay
with electronic SPDT
• 10...40 Vdc rated voltage
• Output with SPDT simulation
• Output voltage 5…48 Vdc 500 mA
• Max switching frequency 1 KHz
• I/O isolation 3.75 kV
79
(3.11 in)
6.2
(0.24 in)
84
(3.31 in)
NOTES
BLOCK DIAGRAM
Compared with standard relays, solid state relays
offers many advantages: much longer life, higher
switching frequency, lower EMI emissions, higher
vibrations withstand capability, wider input voltage
range and 70% lower input corrent. The output of
solid state relays is a N.O. type “contact” and up to
now SPDT type was not available, forcing to use a
standard relay when SPDT function was required.
Thanks to a new technology, this new solid state
relay offers all the advatages of solid state relays with
a SPDT contact output type, making a step ahead
possible.
14
VERSIONS
Pluggable relay
Fixed relay
12 +11
Cat. No. X766083
—
CWOT 6-2083
INPUT TECHNICAL DATA
Input signal
Level 1 (high) input signal (ON)
Level 0 (low) input signal (OFF)
Rated current
Protection device
24 Vdc (range 10…40 Vdc)
>5 Vdc
<5 Vdc
6 mA
suppressor diode
OUTPUT TECHNICAL DATA
Output signal
Continuous load current
Switching delay
Protection device
Output Type
5…48 Vdc
10…500 mA
12 μs ON / 12 μs OFF
suppressor diode
NPN / PNP transistor, with changeover contact simulation
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation
Max. switching frequency
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Connection terminals
Housing material
Approx. weight
Mounting information
-25 …+60°C
3.75 kVac / 60 s
<1 KHz
IP 20 IEC529 EN60529
IEC 664-1, DIN VDE
2
III
2.5 mm² fixed screw type
PPE
29 g (1.02 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay
(1)
Plug-in jumper
—
Marking tags
blank
printed
printed
End plate
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
—
—
—
135
Signal optoisolators
• Suitable for isolation and transmission of digital signal with
high frequency
• Status LED display
• 5, 12 and 24 rated voltage
• I/O isolation
91
(3.59 in)
6
(0.24 in)
NOTES
79
(3.11 in)
100
(3.94 in)
6,2
(0.24 in)
BLOCK DIAGRAM
84
(3.31 in)
BLOCK DIAGRAM
(1) Version available upon request.
CKS1S can isolate I/O high frequency signal circuits
(encoders, counters etc.) to eliminate influence of different
ground reference voltages and ground loops, thus reducing
EMI noise influence on signal transmission of sensitive signals;
it is always recommended to use balanced type shielded
cables (two signal wires + shield); at transmission frequencies
higher than 25 Hz the LED light appears constant, it is to be
intended as “transmission ON” signal.
VERSIONS
Cat. No. XCKS1S
CKS1S (1)
Cat. No. X766082
CWOT 6-2082
INPUT TECHNICAL DATA
Input signal
Level 1 (high) input signal (ON)
Level 0 (low) input signal (OFF)
Rated current
3…30 Vdc
≥ 3 Vdc
≤ 3 Vdc
≤ 10 mA @ 24 Vdc
4.5…28 Vdc
>4.2 Vdc
<2.7 Vdc
0.1 mA
3…30 Vdc
80 mA / 30 Vdc @ 25°C
10 mV / 2 mA
—
5…48 Vdc
10…500 mA
—
12 μs ON / 12 μs OFF
-20…+60°C
3 kVac / 60 s
20 kHz max. duty cycle 50/50, 70/30 max
IP 20 IEC529 EN60529
IEC 664-1, EN50081-1
2
II
2.5 mm2 (AWG 14), AWG26-14 spring type
Polyamide UL94V-0
32 g (1.13 oz)
vertical on rail adjacent without gap
-25…+60°C
3.75 kVac / 60 s
<20 KHz
IP 20 IEC529 EN60529
IEC 664-1, DIN VDE
2
III
2.5 mm2, AWG26-14 a vite
PPE
29 g (1.02 oz)
vertical on rail adjacent without gap
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
—
—
—
OUTPUT TECHNICAL DATA
Output signal
Continuous load current
Min. applicable load
Switching delay
GENERAL TECHNICAL DATA
Operating temperature
I/O isolation
Max. switching frequency
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Connection terminals
Housing material
Approx. weight
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Plug-in jumper
—
Marking tags
blank
printed
printed
End plate
Cat. No. PTCCK42 (42 poles)
Cat. No. NU0851
—
—
Cat. No. XCKPT
136
Solid state 24 Vdc
relay modules
• For DC load
• Pluggable relay
• Status LED display
93
(3.66 in)
93
(3.66 in)
70
(2.76 in)
137
(5.40 in)
75
(2.96 in)
VERSIONS
75
(2.96 in)
NOTES
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here is
to be considered typical.
(2) Version available upon request; for information call
our sales department, local agent or representative
93
(3.66 in)
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
Cat. No. XR042S24
R42S24 (2)
negative common
positive common
Cat. No. XR082S24
Cat. No. XR162S24
4 relay module
R82S24 (2)
R162S24 (2)
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current (1 channel)
Switching frequency
24 Vdc (19.2…28.8 Vdc)
> 19.2 Vdc
< 1 Vdc
< 20 mA
100 Hz max
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Current of the fuse max.
3…50 Vdc
2 A @ 40°C
8 A /10 ms
0.1 mA
100 μs / 1 ms
diodo
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
I/O isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-20...+80°C over 40°C apply a derating of 0.04A/°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm² fixed screw type
UL94V-0 plastic material
207 g (7.31 oz)
379 g (13.38 oz)
756 g (26.69 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
16 relay module
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904404
—
—
—
137
n)
Solid state
24 Vdc
relay modules
93
93
• For AC load
• Pluggable relay
• Status LED display
(3.66 in)
(3.66 in)
(5.40 in)
(2.76 in)
75
(2.96 in)
75
(9.85 in)
75
(2.96 in)
NOTES
VERSIONS
250
(2.96 in)
4 relay module
8 relay module
16 relay module
(3.66 in)
137
70
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here is
to be considered typical.
(2) Version available upon request; for information call
our sales department, local agent or representative
93
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
Cat. No. XR042T24
R42T24 (2)
negative common
positive common
Cat. No. XR082T24
Cat. No. XR162T24
4 relay module
R82T24 (2)
R162T24 (2)
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current (1 channel)
Switching frequency
24 Vdc (19.2…28.8 Vdc)
> 19.2 Vdc
< 1 Vdc
< 20 mA
100 Hz max
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Current of the fuse max.
48…240 Vac (passage à zéro)
3 A @ 40°C
120 A /10 ms
5 mA
1/2 cycle + 1 ms
—
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
I/O isolation
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Modello del relé (1)
Status display
Housing material
Approx. weight (4/8/16 relé)
Mounting information
-20...+80°C over 40°C apply a derating of 0.05A/°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm2 fixed screw type
UL94V-0 plastic material
207 g (7.31 oz)
379 g (13.38 oz)
756 g (26.69 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904405
—
138
16 relay module
Solid state 24 Vdc
relay modules with
fuse
• For DC load
• Protection fuse on output
• Pluggable relay
• Status LED display
93
(3.66 in)
93
(3.66 in)
67
(2.76 in)
137
(5.40 in)
75
(2.96 in)
VERSIONS
75
(2.96 in)
NOTES
4 relay module
8 relay module
16 relay module
250
(9.85 in)
75
(2.96 in)
(1) Relay model is not binding, they may be modified
without prior warning. The technical data shown here is
to be considered typical.
(2) The fuse must be dimensioned according to load.
The max. value of 6.3 A is referred to EN60127complying fuses and the homologation rated current of
the fuse-holder. Fuses of a higher value may damage
the fuse-holder and module.
(3) Version available upon request; for information call
our sales department, local agent or representative
93
(3.66 in)
BLOCK DIAGRAM
POWER SUPPLY
A1 = + A2 = –
A1 = – A2 = +
Cat. No. XR041S24F
R41S24F (3)
negative common
positive common
Cat. No. XR081S24F
Cat. No. XR161S24F
4 relay module
R81S24F (3)
R161S24F (3)
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current (1 channel)
Switching frequency
24 Vdc (19.2…28.8 Vdc)
> 19.2 Vdc
< 1 Vdc
< 20 mA
100 Hz max
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Current of the fuse max.
3…50 Vdc
2 A @ 40°C
8 A /10 ms
0.1 mA
100 μs / 1 ms
diodo
—
8 relay module
GENERAL TECHNICAL DATA
Operating temperature range
I/O isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-20...+80°C over 40°C apply a derating of 0.04A/°C
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED / yellow LED
2.5 mm2 fixed screw type
UL94V-0 plastic material
207 g (7.31 oz)
379 g (13.38 oz)
756 g (26.69 oz)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
Cat. No. 8904404
—
139
16 relay module
Solid state 24 Vdc relay
modules with electronic
protection
• Rated current output 8 x 2.5 A / 5 - 33 Vdc
• Short circuit, overload, over temperature, overvoltage
output protection
• 12-24 Vdc negative common input, 8 status LED
K1 and K8
• 8 output status LED, input/output anti polarity
inversion diodes
• 70 mm wide
93
(3.74 in)
70
(2.76 in)
NOTES
VERSIONS
4 relay module
8 relay module
16 relay module
BLOCK DIAGRAM
1
2
7
+
8
+
–
–
+
SSR4
power on
SSR1
(1) Maximum output current of each channel depends
on surrounding air temperature, on the number of
output contemporarily active and on the current flowing
through them; the given value is measured with 4
active outputs and 4 not active.
(2) All outputs are overcurrent and overtemperature;
when ovd or ovt protections cuts off the output
current, the output display led turns off or reduce its
light depending on ovd degree; the output turns on
automatically when the ovd or ovt are removed.
(3) Version available upon request
70
(2.76 in)
1
2
7
8
–
+
Cat. No. XCOP082
COP082 (3)
INPUT TECHNICAL DATA
Input voltage
Level 1 (high) input signal
Level 0 (low) input signal
Rated current (1 channel)
Switching frequency
5-24 Vdc (range 4.2…32 Vdc) negative common
> 3.5 Vdc
< 3.5 Vdc
5 mA ±10%.
500 Hz
OUTPUT TECHNICAL DATA
Output voltage
Continuous load current
Max. current
Leakage current 0 signal
OFF/ON switching time
Protection circuit
Min. applicable load
12-24 Vdc, (range 5…32 Vdc) negative common
8 x 2.5 A @ 25°C (1)
4.4 A
25 μA max @ 24Vdc
200 Hz (Ton < 500 μs / Toff < 500 μs)
electronic against short circuit / overload / overtemperature (2)
5.2 Vdc/ 100 mA
GENERAL TECHNICAL DATA
Operating temperature range
I/O isolation
Isolation between output terminals
Protection degree
Overvoltage category / Pollution degree
Reference Standard
Status display
Connection terminal
Housing material
Approx. weight
Mounting information
-20...-60°C (with therml protection) (2)
2.5 kVac / 60 s
1 kVac / 60 s (between open contact)
IP 00 IEC 529, EN60529
,,, / 2
IEC 664-1, DIN VDE 0110.1
green LED (DC OK) / yellow LED (output OK)
2.5 mm2 fixed screw type
UL94V-0 plastic material
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Replacement relay (1)
Screw type jumper
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
—
140
These tables allow you to quickly select only the items, then check if all product’s technical data meet your application requirements.
Sub-D / Terminal modules
Diode-holder modules
Dimensions
AxBxC
Tipology
Type
Cat. No.
Page
Version
9 poles
37x66x93
37x66x93
37x66x93
(6)
(5)
(8)
ISD09FM
ISD09PF
ISD09PM
XISD09FM
XISD09PF
XISD09PM
142
142
142
15 poles
47x66x93
47x66x93
47x66x93
(6)
(5)
(8)
ISD15FM
ISD15PF
ISD15PM
XISD15FM
XISD15PF
XISD15PM
25 poles
70x66x93
70x66x93
70x66x93
57x80x93
57x80x93
(6)
(5)
(8)
(5) (11)
(8) (11)
ISD25FM
ISD25PF
ISD25PM
CPD25F
CPD25M
37 poles
107x66x93
107x66x93
107x66x93
77x80x93
77x80x93
(6)
(5)
(8)
(5) (11)
(8) (11)
92x80x93
92x80x93
(5) (11)
(8) (11)
Version
50 poles
Dimensions
AxBxC
Tipology
Type
Cat. No.
Page
8 diodes
25x60x76
45x65x93
45x65x93
(4)
(1)
(2)
CDM08CS
CDM08AC
CDM08CC
XCDM08CS
XCDM08AC
XCDM08CC
159
160
160
142
142
142
16 diodes
50x65x93
92x65x93
92x65x93
(4)
(1)
(2)
CDM16CS
CDM16AC
CDM16CC
XCDM16CS
XCDM16AC
XCDM16CC
159
160
160
XISD25FM
XISD25PF
XISD25PM
XCPD25F
XCPD25M
142
142
142
144
144
24 diodes
71x65x93
137x65x93
137x65x93
137x65x93
(4)
(1)
(2)
(2)
CDM24CS
CDM24AC
CDM24CC
CDM24CC
XCDM24CS
XCDM24AC
XCDM24CC
XCDM24CC
159
160
160
160
ISD37FM
ISD37PF
ISD37PM
CPD37F
CPD37M
XISD37FM
XISD37PF
XISD37PM
XCPD37F
XCPD37M
142
142
142
144
144
CPD50F
CPD50M
XCPD50F
XCPD50M
144
144
Lamp testing modules
Version
Dimensions
AxBxC
10 poles
14 poles
16 poles
Page
45x65x93
45x65x93
45x65x93
(1)
(2)
CLT08AC
CLT08CC
CLP08CC
XCLT08AC
XCLT08CC
XCLP08CC
150
150
151
16 diodes
92x65x93
92x65x93
92x65x93
(1)
(2)
CLT16AC
CLT16CC
CLP16CC
XCLT16AC
XCLT16CC
XCLP16CC
150
150
151
Dimensions
AxBxC
Tipology
Type
Cat. No.
Page
Version
Dimensions
AxBxC
42x66x93
42x66x93
(8)
(8) (7)
IF10PMS
IF10PML
XIF10PMS
XIF10PML
145
145
4 components
25x66x93
(9)
8 components
25x66x93
(10)
48x66x93
48x66x93
(8)
(8) (7)
IF14PMS
IF14PML
XIF14PMS
XIF14PML
145
145
8 components
47x66x93
(9)
8 components
38x66x93
(3)
12 components
70x66x93
(9)
16 components
47x66x93
24 components
70x66x93
(8)
(8) (7)
IF16PMS
IF16PML
XIF16PMS
XIF16PML
145
145
70x66x93
70x66x93
47x80x93
(8)
(8) (7)
(8) (11)
IF20PMS
IF20PML
CPC20M
XIF20PMS
XIF20PML
XCPC20M
145
145
146
26 poles
86x66x93
86x66x93
57x80x93
(8)
(8) (7)
(8) (11)
IF26PMS
IF26PML
CPC26M
XIF26PMS
XIF26PML
XCPC26M
145
145
146
34 poles
107x66x93
107x66x93
70x80x93
(8)
(8) (7)
(8) (11)
IF34PMS
IF34PML
CPC34M
XIF34PMS
XIF34PML
XCPC34M
145
145
146
40 poles
122x66x93
122x66x93
77x80x93
(8)
(8) (7)
(8) (11)
IF40PMS
IF40PML
CPC40M
XIF40PMS
XIF40PML
XCPC40M
145
145
146
50 poles
92x80x93
(8) (11)
CPC50M
XCPC50M
146
60 poles
107x80x93
(8) (11)
CPC60M
XCPC60M
146
64 poli
117x80x93
(8) (11)
CPC64M
XCPC64M
146
(6)
(7)
(8)
(9)
(10)
(11)
Legenda
(1)
(2)
(3)
(4)
(5)
Cat. No.
Component-holder modules
58x66x93
58x66x93
20 poles
Type
8 diodes
Flat / Terminal modules
Version
Tipology
common anode
common cathode
with common terminal
single diode
female connector
141
Tipology
Cat. No.
Page
CCM04SF
XCCM04SF
147
CCM08SV
XCCM08SV
147
CCM08SF
XCCM08SF
147
CCM08CV
XCCM08CV
147
CCM12SV
XCCM12SV
147
(10)
CCM16SV
XCCM16SV
147
(10)
CCM24SV
XCCM24SV
147
female + male connector
with LED
male connector
single component with Faston terminals
single component with terminal blocks
compact dimensions
Type
Passive interfaces
(D-Sub/Terminals
modules) ISD series
C
C
A
C
A
A
B
B
NOTES
B
BLOCK DIAGRAM
These modules allow the transferirng to the terminals of the deriving
signals on a cable with D-Sub connector type
The numeration is “pin-to-pin”.
(1) Version available upon request; for information call our sales
department, local agent or representative
1
2
9
15
25
37
50
1
2
9
15
25
37
50
1
2
9
15
25
37
50
1
2
9
15
25
37
50
1
2
9
15
25
37
1
2
9
15
25
37
1
VERSIONS
9 poles
15 poles
25 poles
37 poles
DIMENSIONS
(A x B x C)
37x66x93 (1.46x2.60x3.66 in)
47x66x93 (1.85x2.60x3.66 in)
70x66x93 (2.76x2.60x3.66 in)
107x66x93 (4.21x2.60x3.66 in)
male
Item
ISD09PM
ISD15PM
ISD25PM
ISD37PM
female
Cat. No. Item
(1)
(1)
(1)
(1)
2
XISD09PM
XISD15PM
XISD25PM
XISD37PM
ISD09PF
ISD15PF
ISD25PF
ISD37PF
(1)
(1)
(1)
(1)
9
15
25
male + female
Cat. No. Item
Cat. No.
XISD09PF
XISD15PF
XISD25PF
XISD37PF
XISD09FM
XISD15FM
XISD25FM
XISD37FM
ISD09FM
ISD15FM
ISD25FM
ISD37FM
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0...50 Vac / 0...75 Vdc
2 A max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
0...50 Vac / 0...75 Vdc
2 A max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
black
142
37
0...50 Vac / 0...75 Vdc
2 A max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
Passive interfaces
(D-Sub/Terminals
modules) ISD series
C
• With LED to display the status
C
A
Item available till sell-out
A
B
NOTES
BLOCK DIAGRAM
These modules allow the transferirng to the terminals of the deriving
signals on a cable with D-Sub connector type
The numeration is “pin-to-pin”
(1) The LEDs are predisposed for a nominal voltage of 24 Vdc and
negative common.
VERSIONS
25 poles
37 poles
B
DIMENSIONS
(A x B x C)
80x66x93 (3.15x2.60x3.66 in)
109x66x93 (4.30x2.60x3.66 in)
1
2
9
15
25
37
1
2
9
15
25
37
C
1
2
9
15
25
37
1
2
9
15
25
37
male
Item
ISD25PML
ISD37PML
female
Cat. No. Item
XISD25PML ISD25PFL
XISD37PML ISD37PFL
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
12...24 Vdc ±10% (1)
2 A max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
C
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
143
Cat. No.
XISD25PFL
XISD37PFL
Passive interfaces
(D-Sub/Terminals
modules) CPD series
C
• Compact dimensions
C
A
A
B
NOTES
BLOCK DIAGRAM
These modules allow the transferirng to the terminals of the deriving
signals on a cable with D-Sub connector type.
The numeration is “pin-to-pin”.
(1) Version available upon request; for information call our sales
department, local agent or representative
VERSIONS
25 poles
37 poles
50 poles
B
DIMENSIONS
(A x B x C)
57x80x93 (2.24x3.15x3.66 in)
77x80x93 (3.03x3.15x3.66 in)
92x80x93 (3.62x3.15x3.66 in)
1
2
9
15
25
37
50
1
2
9
15
25
37
50
1
2
9
15
25
37
50
1
2
9
15
25
37
50
male
female
Item
Cat. No. Item
CPD25M
CPD37M
CPD50M (1)
XCPD25M CPD25F
XCPD37M CPD37F
XCPD50M CPD50F (1)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0...50 Vac / 0...75 Vdc
2 A max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
144
Cat. No.
XCPD25F
XCPD37F
XCPD50F
Passive interfaces
(I.D.C./Terminal blocks)
IF series
C
• Available with LED to display the status
C
A
A
B
NOTES
BLOCK DIAGRAM
The modules allow the transfering to the terminals the deriving signals
on Flat-cable through the employment of IDC ribbon cable connectors
(with insulation displacement).
The numeration is “pin-to-pin”.
(1) Version available upon request; for information call our sales department, local agent or representative
(2) The LEDs are predisposed for a nominal voltage of 24 Vdc and
negative common
VERSIONS
10 poles
14 poles
16 poles
20 poles
26 poles
34 poles
40 poles
B
DIMENSIONS
(A x B x C)
42x66x93 (1.65x2.60x3.66 in)
48x66x93 (1.89x2.60x3.66 in)
58x66x93 (2.28x2.60x3.66 in)
70x66x93 (2.76x2.60x3.66 in)
86x66x93 (3.39x2.60x3.66 in)
107x66x93 (4.21x2.60x3.66 in)
122x66x93 (4.80x2.60x3.66 in)
1
2
20
26
34
40
50
1
2
20
26
34
40
50
1
2
20
26
34
40
50
1
2
20
26
34
40
50
Without LED
Item
IF10PMS
IF14PMS
IF16PMS
IF20PMS
IF26PMS
IF34PMS
IF40PMS
With LED
Cat. No. Item
(1)
(1)
(1)
(1)
(1)
(1)
(1)
XIF10PMS
XIF14PMS
XIF16PMS
XIF20PMS
XIF26PMS
XIF34PMS
XIF40PMS
IF10PML
IF14PML
IF16PML
IF20PML
IF26PML
IF34PML
IF40PML
Cat. No.
(1)
(1)
(1)
(1)
(1)
(1)
(1)
XIF10PML
XIF14PML
XIF16PML
XIF20PML
XIF26PML
XIF34PML
XIF40PML
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0...50 Vac / 0...75 Vdc
750 mA max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
12...24 Vdc ±10% (2)
750 mA max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
C
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
145
Passive interfaces
(I.D.C./Terminal blocks)
CPC series
C
• Compact dimensions
A
B
NOTES
BLOCK DIAGRAM
The modules allow the transferring to the terminals of the deriving
signals on Flat-cable through the employment of IDC ribbon cable
connectors (with insulation displacement).
The numeration is “pin-to-pin”.
(1) Version available upon request; for information call our sales department, local agent or representative.
VERSIONS
20 poles
26 poles
34 poles
40 poles
50 poles
60 poles
64 poles
DIMENSIONS
(A x B x C)
47x80x93 (1.85x3.15x3.66 in)
57x80x93 (2.24x3.15x3.66 in)
70x80x93 (2.76x3.15x3.66 in)
77x80x93 (3.03x3.15x3.66 in)
92x80x93 (3.62x3.15x3.66 in)
107x80x93 (4.21x3.15x3.66 in)
117x80x93 (4.61x3.15x3.66 in)
1
2
20
26
34
40
50
1
2
20
26
34
40
50
without LED
Item
Cat. No.
CPC20M
CPC26M
CPC34M
CPC40M
CPC50M
CPC60M
CPC64M
XCPC20M
XCPC26M
XCPC34M
XCPC40M
XCPC50M
XCPC60M
XCPC64M
(1)
(1)
(1)
(1)
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0...50 Vac / 0...75 Vdc
750 mA max.
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
146
Component-holders
modules CCM series
• Compact dimensions
• Available with fast-on connection
C
C
A
A
A
B
B
NOTES
4 components
8 components
8 components
8 components
12 components
16 components
24 components
DIMENSIONS
(A x B x C)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
B
BLOCK DIAGRAM
The component-holders modules allow the montage of electronic
components (diodes, resistors, capacitors etc.) according to customer
needs.
They are available with connections with terminal blocks or Faston, and
with holes of different diameters for the terminals of the components.
(1) Version available upon request; for info call our sales dept., local
agent or representative
VERSIONS
C
25x66x93 (0.98x2.60x3.66 in)
25x66x93 (0.98x2.60x3.66 in)
47x66x93 (1.85x2.60x3.66 in)
25x55x93 (0.98x2.17x3.66 in)
70x66x93 (2.76x2.60x3.66 in)
47x66x93 (1.85x2.60x3.66 in)
70x66x93 (2.76x2.60x3.66 in)
C
2
4
6
8
16
15
14
13
12
11
10
9
16
15
14
13
12
11
10
9
C
1
3
5
7
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
with common terminal
single with terminals
single with Faston
Item
Cat. No. Item
Cat. No. Item
Cat. No.
—
—
—
CCM08CV
—
CCM08SV
—
—
—
XCCM08CV
—
CCM16CV
—
CCM04SF
XCCM08SV
XCCM16CV CCM16SV
CCM24SV
XCCM04SF
—
CCM08SF
XCCM08SF
—
CCM12SF
XCCM16SV
XCCM24SV
XCCM12SF
—
—
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0...220 V ±10%
5 A (chanel) / 15 A (common)
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
0...100 V ±10%
2 A max. (on the common)
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
black
The PMC series has changed its Cat. No. into CCM series, these are the cross reference list.
Old item
New item
PMC0001
CCM08CV
PMC0002
CCM08SV
PMC0003
CCM16SV
PMC0004
CCM24SV
PMC0005
CCM04SF
PMC0006
CCM08SF
PMC0007
CCM12SF
147
0...100 V ±10%
2 A max. (on the common)
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
Diode-holder modules
with single diodes
CDM series
C
A
A
B
NOTES
VERSIONS
8 diodes
16 diodes
24 diodes
25x60x76 (0.98x2.36x3.66 in)
50x65x93 (1.97x2.56x3.66 in)
71x65x93 (2.80x2.56x3.66 in)
1A
2A
3A
4A
5A
6A
7A
8A
16A
24A
1C
2C
3C
4C
5C
6C
7C
8C
16C
24C
single diode
Item
CDM08CS
CDM16CS
CDM24CS
Cat. No.
XCDM08CS
XCDM16CS
XCDM24CS
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Diode type
Repetitive peak reverse voltage
Operating temperature
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0…100 V ±10%
1 A max.
1N4007
1000 V
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
148
C
A
B
BLOCK DIAGRAM
DIMENSIONS
(A x B x C)
C
B
Diode-holder modules
with common terminal
CDM series
C
A
B
NOTES
BLOCK DIAGRAM
C
VERSIONS
8 diodes
16 diodes
24 diodes
DIMENSIONS
(A x B x C)
45x65x93 (1.77x2.56x3.66 in)
92x65x93 (3.62x2.56x3.66 in)
137x65x93 (5.39x2.56x3.66 in)
1
3
5
7
15
23
2
4
6
8
16
24
Item
CDM08AC
CDM16AC
CDM24AC
C
1
3
5
7
15
23
2
4
6
8
16
24
common anode
common cathode
Cat. No. Item
Cat. No.
XCDM08AC CDM08CC
XCDM16AC CDM16CC
XCDM24AC CDM24CC
GENERAL TECHNICAL DATA
Rated voltage
Rated current
Operating temperature
Diode type
Repetitive peak reverse voltage
Protection degree
Reference Standard
Pollution degree
Overvoltage category
Housing material
Connection terminal blocks
Mounting information
0…230 V ±10%
1 A (channel) / 15 A (common).
1N4007
1000 V
-20…+60°C
IP00 IEC529; EN60529
IEC 664-1; DIN VDE 0110.1
2
II
polyamide UL94V-0
2.5 mm2 fixed screw type (AWG 14)
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
PR/3/AC - PR/3/AS
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
149
XCDM08CC
XCDM16CC
XCDM24CC
LED testing modules
CLT series
• Compact dimensions
• Integrated limitation resistence
• Suitable only for LED without resistance limiter
• Not suitable for LED lamp with internal limiter circuit
C
A
B
NOTES
BLOCK DIAGRAM
(1) Led test can be performed through a negative signal on the common output
(2) Led test can be performed hrough a positive signal on the common
input
(3) Version available upon request; for information call our sales department, local agent or representative
VERSIONS
8 channels
16 channels
DIMENSIONS
(A x B x C)
45x65x93 (1.77x2.56x3.66 in)
92x65x93 (3.62x2.56x3.66 in)
Item
common negative (1)
common positive (2)
Cat. No. Item
Cat. No.
CLT08AC (3)
CLT16AC (3)
XCLT08AC CLT08CC (3)
XCLT16AC CLT16CC (3)
GENERAL TECHNICAL DATA
Rated voltage
Rated current (1 channel)
Diode type
Limitation resistence
Repetitive peak reverse voltage
Operating temperature
Housing material
Protection degree
Connection terminal blocks
Mounting information
24 Vdc max. 30 Vdc
5 mA @ 24 Vdc
1N4007
4,7 kΩ 1/4 W ±5%
1000 V
-20…+45°C
polyamide UL94V-0
IP 00 IEC529, EN60529
2.5 mm2 fixed screw type
vertical on rail adjacent without gap
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
150
XCLT08CC
XCLT16CC
Lamp testing modules
CLP series
• Compact dimensions
• Suitable also for LED lamp with resistance limiter
C
A
B
NOTES
BLOCK DIAGRAM
With AC input, the diodes rectify the current and the power will be
halved.
(1) Led test can be performed through a negative signal on the
common output
(2) Led test can be performed hrough a positive signal on the common
input
VERSIONS
8 channels
16 channels
DIMENSIONS
(A x B x C)
Item
common negative (1)
common positive (2)
Cat. No. Item
Cat. No.
45x65x93 (1.77x2.56x3.66 in)
92x65x93 (3.62x2.56x3.66 in)
CLP08CC
CLP16CC
GENERAL TECHNICAL DATA
Rated voltage
Rated current (1 channel)
230 Vac/dc
100 mA @ 120 Vac/dc;
50 mA @ 230 Vac/dc
1N4007
0
700 V
-20…+45°C
polyamide UL94V-0
IP 00 IEC529, EN60529
2.5 mm2 fixed screw type
vertical on rail adjacent without gap
Diode type
Limitation resistence
Repetitive peak reverse voltage
Operating temperature
Housing material
Protection degree
Connection terminal blocks
Mounting information
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35
Mounting rail type according to IEC60715/G32
Jumper bridge
black
PR/3/AC – PR/3/AC/ZB – PR/3/AS – PR/3/AS/ZB
PR/DIN/AC - PR/DIN/AS - PR/DIN/AL
—
151
XCLP08CC
XCLP16CC
Housing for custom
applications CH series
CH-B12.5
• Available on 3 measures
CH-C
CH-C10
CH-C22.5
NOTES
CH-C32.5
CH-CA
CH-CF
BLOCK DIAGRAM
(1) Maximum height of the components measured
between the circuit and the cover
VERSIONS
Item
Right side with hook for DIN rail, 12.5 mm
Left side housing, 10 mm
Left side housing, 22.5 mm
Left side housing, 32.5 mm
Openable hinged cover
Vented cover
Enclosed cover
fixed hinged cover
Cat. No.
CH-B12.5
CH-C10
CH-C22.5
CH-C32.5
CH-S
CH-CA
CH-C
CH-CF
XBB125
XBC010
XBC225
XBC325
XBS000
XBCA00
XBC000
XBCF00
GENERAL TECHNICAL DATA
Material
Colour
Temperature
Dissipated power
Protection degree
Number of poles for every side
Number of poles on the top
Mounting information
Poliammide UL94V-0
RAL 5014
max 80 °C
max 7 W
fino a IP30
16 +16 (5.08)
10 (5.08)
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Jumper bridge
red
white
blue
PR/3/AC, PR/3/AS
—
—
—
—
APPLICATIONS
CH electronic housings
With the CH (Cabur Housing) series containers, Cabur proposes a modular
system which allows you to obtain boxes with 3 width sizes 22.5 mm - 35
mm - 45 mm - composed by 8 easy-to-assemble parts.
The circuit can have a maximum size of 102 x 74 mm and can be inserted
on 4 small columns formed in the base which holds it in position.
Additional anchorage of the circuit is possible with a 2.2 x 4.5 mm selfthreading screw to be screwed into the central column, also allowing small
circuit to be mounted.
The conductors are connected with 2.5 mm pluggable terminals, which are
readily available.
16 connection poles which can be used with pitch of 5.08 on each side and
10 on the front side.
The CH-S front closure, with panel opening, provides access to the internal
circuit for work on the potentiometers, jumpers and micro-switches.
The side covers are availbale with ventilating holes or closed, and are precutted with 5.08 mm pitch, to make possible an easy cut into necessary
lenght with a pair of scissors, for an easy fit to final dimensions.
The following are required for a composition of a housing::
• 1 CH-B12.5 base
12.5 mm wide
• 1 cover (3 sizes available)
CH-C10
10 mm wide
CH-C22.5 22.5 mm wide
CH-C32.5 32.5 mm wide
(by adding together the width of the base 12.5 mm with the width of the
cover chosen from the 4 available, the total width of the housing is obtained)
• 1 front closure in two versions:
CH-S
CH-CF
with panel opening
fixed
CH-C
CH-CA
without vents
with vents
• 2 side closures in two versions:
Interior
height
max (1)
CH-B12.5
CH-C10
19.1 mm
1
1
31.6 mm
1
41.6 mm
1
CH-C22.5
CH-C32.5
1
1
CH-S
CH-CA
CH-C
1
2
1
2
1
2
152
Housing for custom
applications CK series
• 6 mm wide, expandable modules
• 6 spring-clamp 2,5 mm2 / AWG 26 ÷ 14 terminal blocks
• Jumper insertion possibility on each of the 4 levels
• Hinged front cover access to the printed circuit board
NOTES
BLOCK DIAGRAM
CKB e CKBG
(1) 6 spring-clamp terminal blocks included with
solder contact
(2) In order to assure the IP20 protection degree,
the last module must be protected and insulated
using the CK/PT end section
VERSIONS
CKBX2
Item
Standard base
Base element with ground contact
Expansion module
End section
Front hinge cover
Printed circuit board
CKPT
Cat. No.
CKB (1)
CKBG (1)
CKBX2 (1)
CK/PT
CK/S
CK/PCB
XCKB
XCKBG
XCKX2
XCKPT
XCKS
8901028
GENERAL TECHNICAL DATA
Rated voltage of each terminal block
Rated current of each terminal block
Operating temperature
Protection degree (2)
Connection terminals
Housing material
Approx. weight
Parallel bridge
Marking tags
blank
230 Vac/dc ± 10%
≤ 24 A
-40...+ 100°C
IP20 IEC529 EN60529
2.5 mm2, AWG26-14 spring type
polyamide UL 94V0
20 g (CKB, CKBG), 15 g (CKX2, CK/PT)
20 g (CK/PT), 1 g (CK/S), 5 g (CK/PCB)
PTC/CK/42
Cat. No. PTCCK42 (42 poli)
CNU/8/030
Cat. No. NU0851
Mounting information
on rail
MOUNTING ACCESSORIES
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
Jumper bridge
red
white
blue
Ground contact on CKBG
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
—
—
—
CKBX2
CKB
153
CKS
CKPCB
APPLICATIONS
With the CK series modular housings, Cabur offers a modular system
that provides housings with increasing dimensions in width for simple
components as diodes, resistors or more complex circuits with or without
the support of a printed circuit board. For the composition of an housing the
following items are necessary:
• a base support element, available in two versions: CKB and CKBG; the
latter is provided with an electric metal contact on the DIN rail that allows
to connect the internal circuit to the ground. Ground contact towards the
DIN rail can carry an impulsive current value of 5 KA (8/20 peak). Both
models have an external width of 6 mm and internal width of 5 mm; they
are also equipped with 6 springclamp terminal blocks and 4 slots for the
insertion of a jumper;
• one or more CKBX2 type expansion modules similar to the base support
element, having therefore an external width of 6 mm and a central slot
that allows the housing of the bulky components with a height exceeding
the overall height of the base support element; the expansion module is
also equipped with 6 spring-clamp terminal blocks and 4 slots for the
insertion of a jumper;
• the CK/S front cover, granting access to the interior of the product, is
also available. Once in open position it has such a dimension in order to
guarantee a IPXXB degree of protection, even when it is not employed;
• in order to assure the IPXXB protection degree, the last module must be
protected and insulated using the CK/PT end section;
• the CK/PCB printed circuit board is also available; it is useful in low volume
custom applications where a special pcb is not designed and also where
one requires a prototype without tooling a special printed circuit board.
CK/PCB
Plug-in jumper for CK series
Notes:
(1) Example of a pre-cut 9 position jumper
(2) CK/PT end section must be mounted on last module to assure
IP20 protection degree
(3) 32 A is the maximum current; however this value is limited by
the rated current of the spring-clamp terminal blocks down to
24 A; for instance, having a jumper of 11 poles (1 for common
and 10 for distribution) a current of 2.4 A can be distributed on
every poles
(1)
VERSIONS
Item
Cat. No.
PTC/CK/42
PTCCK42
GENERAL TECHNICAL DATA
Protection degree (2)
Number of poles
Pitch
Rated current carrying capacity of jumper (3)
Insulation color
Material
Approx. weight
IP20 IEC529; EN60529
42
6 mm (0.24 in)
32 A
—
tin copper alloy
27 g (0.95 oz) (42 poles)
Plug-in jumper for CW..7 series
VERSIONS
Item
Cat. No. Item
CWBK 7-0802
Cat. No. Item
X766802 CWBK 7-0803
Cat. No.
X766803 CWBK 7-0804
GENERAL TECHNICAL DATA
Protection degree
Number of poles
Pitch
Rated current carrying capacity of jumper
Insulation color
Material
Approx. weight
IP20 IEC529; EN60529
16
6.2 mm (2.44 in)
16 A
red
—
4 g (0.14 oz)
IP20 IEC529; EN60529
16
6.2 mm (2.44 in)
16 A
white
—
4 g (0.14 oz)
Plug-in jumper for CWRE series
VERSIONS
Item
Cat. No.
CWBK 7-0813
X766813
GENERAL TECHNICAL DATA
Protection degree
Number of poles
Pitch
Rated current carrying capacity of jumper
Insulation color
Material
Approx. weight
IP20 IEC529; EN60529
20
6.2 mm (2.44 in)
16 A
blue
—
6 g (0.21 oz)
154
IP20 IEC529; EN60529
16
6.2 mm (2.44 in)
16 A
blue
—
4 g (0.14 oz)
X766804
Screw type
jumper for CM
series
VERSIONS
Item
Cat. No. Item
Cat. No.
CMB16B
XCMB16B CMB27B
XCMB27B
GENERAL TECHNICAL DATA
Protection degree
Number of poles
Pitch
Rated current carrying capacity of jumper
Insulation color
Material
Approx. weight
IP20 IEC529; EN60529
8
16 mm (0.63 in)
16 A
black
—
3 g (0.10 oz)
IP20 IEC529; EN60529
8
27 mm (1.06 in)
16 A
black
—
3 g (0.10 oz)
Marking systems
Note:
White polycarbonate marking tags to number
the terminal blocks of the CK Series modules
and CWRE Series converters. To be directly
inserted in dedicated holders before or after terminal board preparation. They come in packages of 15 modules of 100 marking tags each,
for a total of 1,500 marking tags. The table
shows only blank marking tags, available in
packages of 1,500 pieces each, which can be
written on manually using special pens or printed using an industrial marking system. In particular, the marking tags shown here can
be printed using the innovative CaburJet
system and with the CaburPlot plotter.
In addition to blank marking tags, CNU/8/51
preprinted marking tags are also available with
alpha-numeric characters and with the most
common electrical symbols.
For more information, please consult the
Industrial Marking Systems catalogue.
Type CNU/8/51 code NU0851
Type NUPUTUK50 code NUPUTUK50
Description
Marking tags for marking CK Series modules
Marking tags for marking CWRE Series converters
Sigle
Code
CNU/8/51
NU0851
NUPUTUK50
NUPUTUK50
Bracket for power supplies
VERSIONS
Sigle
DIMENSION
Code
CDIWMP
XCDIWMP
GENERAL TECHNICAL DATA
155
P13-FE00 aluminium
“SENDZMIR” system
screws or rivets
Type of material
Treatment
Mounting information
DIN rail clamp
DIMENSION
VERSIONS
Item
Cat. No. Item
CDIN-2
Cat. No.
XCDIN2 CDIN-4
XCDIN4
GENERAL TECHNICAL DATA
Type of material
Treatment
Mounting information
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
P13-FE00
black passivated
screws or rivets
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
aluminium
—
screws or rivets
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
DIMENSION
VERSIONS
Item
Cat. No. Item
CDIN-5
Cat. No.
XCDIN5 CDINM45
XCDINM45
GENERAL TECHNICAL DATA
Type of material
Treatment
Mounting information
Mounting rail type according to IEC60715/TH35-7.5
Mounting rail type according to IEC60715/G32
P13-FE00
white zinc-plated
screws or rivets
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
156
P13-FE00
zinc-plated
screws
PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB
—
Mounting rails
• according to IEC 60715/TH35 - 7,5
• according to IEC 60715/TH35 - 15
• supports for TH/35 type rail
DESCRIPTION
IEC 60715/TH35 - 7.5 rail
of passivated steel
TYPE / CAT. NO.
PR/3/AC
Cat. No. PR003
IEC 60715/TH35 - 7.5 rail
of white zinc-plated steel
“SENDZMIR” system
PR/3/AC/ZB
IEC 60715/TH35 - 7.5 rail
of passivated steel with slots
PR/3/AS
Cat. No. PR903
Cat. No. PR005
IEC 60715/TH35 - 7.5 rail
of white zinc-plated steel
“SENDZMIR” system with slots
PR/3/AS/ZB
IEC 60715/TH35 - 15 rail
of passivated steel
PR/3/PP
Cat. No. PR905
Cat. No. PR007
IEC 60715/TH35 - 15 rail
of white zinc-plated steel
“SENDZMIR” system
PR/3/PP/ZB
IEC 60715/TH35 - 15 rail
of passivated steel with slots
PR/3/PA
Cat. No. PR907
Cat. No. PR006
IEC 60715/TH35 - 15 rail
of white zinc-plated steel
“SENDZMIR” system with slots
PR/3/PA/ZB
Support for IEC 60715/TH35 rail
of nickel plated steel and with rapid mounting system
4 MA
ACI121017
Support for IEC 60715/TH35 rail
of nickel plated steel and with rapid mounting system
5 MA
ACI121019
Cat. No. PR906
Cat. No. Z121017
Cat. No. Z121019
157
BLOCK DIAGRAMS
Mounting rails
• according to IEC 60715 “G32” type rail
• according to IEC 60715/TH15 - 5.5
DESCRIPTION
IEC 60715 “G32” type rail
of passivated steel
TYPE / CAT. NO.
PR/DIN/AC
Cat. No. PR001
IEC 60715 “G32” type rail
of white zinc-plated steel
“SENDZMIR” system
PR/DIN/AC/ZB
IEC 60715 “G32” type rail
of passivated steel with slots
PR/DIN/AS
Cat. No. PR901
Cat. No. PR004
IEC 60715 “G32” type rail
of white zinc-plated steel
“SENDZMIR” system with slots
PR/DIN/AS/ZB
IEC 60715 “G32” type rail
of aluminium
PR/DIN/AL
Cat. No. PR904
Cat. No. PR002
IEC 60715/TH15 – 5.5 rail
of passivated steel
PR/2/AC
Cat. No. PR009
IEC 60715/TH15 – 5.5 rail
of white zinc-plated steel
“SENDZMIR” system
PR/2/AC/ZB
IEC 60715/TH15 – 5.5 rail
of passivated steel with slots
PR/2/AS
Cat. No. PR909
Cat. No. PR010
IEC 60715/TH15 – 5.5 rail
of white zinc-plated steel
“SENDZMIR” system with slots
PR/2/AS/ZB
Cat. No. PR910
158
IMAGES
Alphabetical index
TYPE
ACI121017
ACI121019
AR1
AR6
BATT12V1.2AH
BY7-40/1-275
BY7-40/1-440
BY7-NPE/40-275
BY7-NPE/40-440
CAPIPO3
CCIS2
CCM04SF
CCM08CV
CCM08SF
CCM08SV
CCM12SF
CCM16CV
CCM16SV
CCM24SV
CDIN-2
CDIN-4
CDIN-5
CDINM45
CDIWMP2
CDM08AC
CDM08CC
CDM08CS
CDM16AC
CDM16CC
CDM16CS
CDM24AC
CDM24CC
CDM24CS
CEP-BCB
CEP-BCR
CEP-D1
CEP-D2
CEP-D3
CEP-MTW
CEP-RCC
CEP-RCP
CEP-SS
CH-B12,5
CH-C
CH-C10
CH-C22,5
CH-C32,5
CH-CA
CH-CF
CH-S
CI-NPN/PNP
CK/PT
CK/S
CKB
CKBG
CKBX2
CK-PCB
CKR16
CKR25
CKS15E
CKS15NA
CKS15NB
CKS1S
CKS22
CL1R
CL5R
CLP08CC
CLP16CC
CLT08AC
CLT08CC
CLT16AC
CLT16CC
CM1A012
CM1A024
CM1A120
CM1A230
CM1C012
CM1C024
CM1C048
CM1C110
CM1S024
CM1S024E
CM1T024
CM1T024E
CM2A012
CM2A024
CM2A120
CM2A230
CM2C012
CM2C024
CM2C048
CM2C110
CM4C012
CM4C024
CMB16B
CMB27B
CNU/8/51
PAGE
157
157
50
50
56
62
62
62
62
81
93
147
147
147
147
147
147
147
147
156
156
156
156
155
149
149
148
149
149
148
149
149
148
65
65
65
65
65
65
65
65
65
152
152
152
152
152
152
152
152
99
153
153
153
153
153
153
109
109
134
133
133
136
134
49
49
151
151
150
150
150
150
106
106
106
106
103
103
103
103
131
131
132
132
106
107
107
107
104
104
104
104
105
105
155
155
155
TYPE
COP082
CPC20M
CPC26M
CPC34M
CPC40M
CPC50M
CPC60M
CPC64M
CPD25F
CPD25M
CPD37F
CPD37M
CPD50F
CPD50M
CR4-1
CR4-2SC
CR8-1
CR8-3
CRE4-1
CRE4-2SC
CRE8-1
CRE8-3
CSA120BC
CSA120BD
CSA120CB
CSA120CC
CSA120DB
CSA120DC
CSA240FC
CSBC
CSBD
CSBP30Y
CSC120B
CSC120C
CSD15B
CSD15C
CSD30C
CSD30E
CSD30F
CSD50B
CSD70C
CSF120B
CSF120C
CSF120CP
CSF120DP
CSF240B
CSF240C
CSF240CP
CSF240DP
CSF240G
CSF30B
CSF30C
CSF500C
CSF500D
CSF500G
CSF5-65
CSF85B
CSF85C
CSF85CP
CSG2401C
CSG2401D
CSG2401G
CSG2401R
CSG481C
CSG500C
CSG500D
CSG500G
CSG720C
CSG720D
CSG960C
CSG960D
CSG960G
CSL120C
CSL481C
CSR50U
CSU070S
CSU240S
CSU500S
CS-UPS1
CS-UPS2
CSW121B
CSW121C
CSW121DP
CSW241B
CSW241C
CSW241DP
CSW241G
CSW481C
CSW481D
CSW481G
CWAA7-0530
CWAA7-0531
CWAA7-0532
CWAA7-0533
CWAA7-0534
CWAA7-0535
CWAA7-0536
PAGE
TYPE
140
146
146
146
146
146
146
146
144
144
144
144
144
144
122
123
122
126
122
123
122
126
46
46
46
46
47
47
48
51
58
56
57
57
17
17
18
18
18
19
20
24
24
24
24
25
25
25
25
26
22
22
27
27
28
29
23
23
23
44
44
45
45
40
41
41
41
42
42
43
43
43
32
34
59
53
54
55
52
52
36
36
36
37
37
37
37
38
38
38
84
84
84
85
85
85
86
CWAA7-0537
CWAA7-0538
CWBK7-0802
CWBK7-0803
CWBK7-0804
CWBK7-0813
CWCV7-6184
CWNAA6-0510
CWNAA7-0539
CWNFA6-0524
CWOT6-2082
CWOT6-2083
CWPAA7-0526
CWPAA7-0527
CWPT6-0816
CWPT6-0817
CWRE7-0842
CWRE7-0845
CWRE7-0846
CWRE7-0847
CWRE7-0848
CWTH6-0844
CWTH6-0847
CWUAA6-0516
CWUAA6-0517
F03DKBG5B
F03DPCG5C
F06DKBG5B
F06DPCG5C
F07TDVST2
F100TDVST2
F100TYT2
F10TYG9
F12DKBG5B
F12DPCG5C
F150TDS84C
F16DKCG5B
F16DPCG5C
F16TDVST2
F16TYT2
F180TDS84C
F200TDDS84C
F20DKCG5B
F20DPCG5C
F20TYS9
F25TYT2
F300TDSS84C
F30DKCS5B
F30DPGS5C
F30TDVST2
F36TYT2
F400TDSS84C
F42TDVST2
F50TYT2
F55TDVST2
F75TDVST2
IF10PML
IF10PMS
IF14PML
IF14PMS
IF16PML
IF16PMS
IF16S7
IF20PML
IF20PMS
IF26PML
IF26PMS
IF34PML
IF34PMS
IF40PML
IF40PMS
IF416LS7
IF416S7
ISD09FM
ISD09PF
ISD09PM
ISD15FM
ISD15PF
ISD15PM
ISD25FM
ISD25PF
ISD25PFL
ISD25PM
ISD25PML
ISD37FM
ISD37PF
ISD37PFL
ISD37PM
ISD37PML
LCONALSFDT
LCONTADFDT
LCONTLSFDT
LCONZBUSB
MBC2K
NUPUTUK50
O332060
O332240
159
PAGE
86
86
154
154
154
154
98
83
83
97
136
135
87
87
91
91
110
110
110
110
110
92
92
82
82
74
75
74
75
68
68
72
73
74
75
69
74
75
68
72
69
70
74
75
73
72
71
74
75
68
72
71
68
72
68
68
145
145
145
145
145
145
125
145
145
145
145
145
145
145
145
125
125
142
142
142
142
142
142
142
142
143
142
143
142
142
143
142
143
88
89
90
88
60
155
130
130
TYPE
PR/2/AC
PR/2/AC/ZB
PR/2/AS
PR/2/AS/ZB
PR/3/AC
PR/3/AC/ZB
PR/3/AS
PR/3/AS/ZB
PR/3/PA
PR/3/PA/ZB
PR/3/PP
PR/3/PP/ZB
PR/DIN/AC
PR/DIN/AC/ZB
PR/DIN/AL
PR/DIN/AS
PR/DIN/AS/ZB
PTC/CK/42
R161E11A
R161E22A
R161E24
R161E24P
R161EAD
R161S24F
R161U24F
R162E24
R162E24P
R162EAD
R162S24
R162T24
R41E11A
R41E22A
R41E24
R41E24P
R41EAD
R41S24F
R41U24F
R42E24
R42E24P
R42EAD
R42S24
R42T24
R81E11A
R81E22A
R81E24
R81E24P
R81EAD
R81S24F
R81U24F
R82E24
R82E24P
R82EAD
R82S24
R82T24
RE1024D
RE1824D
RE2024D
RF1012D
RF1024D
RF1824D
RFA024D
RFE16124
RFE16224
RFE8124
RFE8224
RMP081CM
SW01VA
SW05VA
SW10VA
SW20VA
SW50VA
WAA7-0540
WAA7-0541
WAA7-0542
PAGE
158
158
158
158
157
157
157
157
157
157
157
157
158
158
158
158
158
154
120
121
112
113
114
139
115
116
117
118
137
138
120
121
112
113
114
139
115
116
117
118
137
138
120
121
112
113
114
139
115
116
117
118
137
138
101
101
102
102
101
101
101
128
128
126
127
120
95
95
95
96
96
94
94
94
Index by Catalogue number
CODE
8901028
8911012
ISPD1425G
ISPD14275
ISPD14440
ISPD1444G
NU0851
NUPUTUK50
PR001
PR002
PR003
PR004
PR005
PR006
PR007
PR009
PR010
PR901
PR903
PR904
PR905
PR906
PR907
PR909
PR910
PTCCK42
X756340
X756360
X756370
X756510
X756516
X756517
X756524
X756526
X756527
X756530
X756531
X756532
X756533
X756534
X756535
X756536
X756537
X756538
X756539
X756540
X756541
X756542
X756816
X756817
X756844
X756847
X756894
X766082
X766083
X766184
X766802
X766803
X766804
X766813
X766842
X766845
X766846
X766847
X766848
XAR1
XAR6
XBB125
XBC000
XBC010
XBC225
XBC325
XBCA00
XBCF00
XBS000
XCAPIPO3
XCCIS2
XCCM04SF
XCCM08CV
XCCM08SF
XCCM08SV
XCCM12SF
XCCM16CV
XCCM16SV
XCCM24SV
XCDIN2
XCDIN4
XCDIN5
XCDINM45
XCDIWMP2
XCDM08AC
XCDM08CC
XCDM08CS
XCDM16AC
XCDM16CC
XCDM16CS
XCDM24AC
PAGE
153
56
62
62
62
62
155
155
158
158
157
158
157
157
157
158
158
158
157
158
157
157
157
158
158
154
89
88
90
83
82
82
97
87
87
84
84
84
85
85
85
86
86
86
83
94
94
94
91
91
92
92
88
136
135
98
154
154
154
154
110
110
110
110
110
50
50
152
152
152
152
152
152
152
152
81
93
147
147
147
147
147
147
147
147
156
156
156
156
155
149
149
148
149
149
148
149
CODE
XCDM24CC
XCDM24CS
XCEPBCB
XCEPBCR
XCEPD1
XCEPD2
XCEPD3
XCEPMTW
XCEPRCC
XCEPRCP
XCEPSS
XCKB
XCKBG
XCKPT
XCKR16
XCKR25
XCKS
XCKS15E
XCKS15NA
XCKS15NB
XCKS1S
XCKS22
XCKX2
XCL1R
XCL5R
XCLP08CC
XCLP16CC
XCLT08AC
XCLT08CC
XCLT16AC
XCLT16CC
XCM1A012
XCM1A024
XCM1A120
XCM1A230
XCM1C012
XCM1C024
XCM1C048
XCM1C110
XCM1S024
XCM1S024E
XCM1T024
XCM1T024E
XCM2A012
XCM2A024
XCM2A120
XCM2A230
XCM2C012
XCM2C024
XCM2C048
XCM2C110
XCM4C012
XCM4C024
XCMB16B
XCMB27B
XCOP082
XCPC20M
XCPC26M
XCPC34M
XCPC40M
XCPC50M
XCPC60M
XCPC64M
XCPD25F
XCPD25M
XCPD37F
XCPD37M
XCPD50F
XCPD50M
XCR41
XCR42SC
XCR81
XCR83
XCRE41
XCRE42SC
XCRE81
XCRE83
XCSA120BC
XCSA120BD
XCSA120CB
XCSA120CC
XCSA120DB
XCSA120DC
XCSA240FC
XCSBC
XCSBD
XCSBP30Y
XCSC120B
XCSC120C
XCSD15B
XCSD15C
XCSD30C
XCSD30E
XCSD30F
XCSD50B
XCSD70C
XCSF120B
PAGE
CODE
149
148
65
65
65
65
65
65
65
65
65
153
153
153
109
109
153
134
133
133
136
134
153
49
49
151
151
150
150
150
150
106
106
106
106
103
103
103
103
131
131
132
132
106
107
107
107
104
104
104
104
105
105
155
155
140
146
146
146
146
146
146
146
144
144
144
144
144
144
122
123
122
126
122
123
122
126
46
46
46
46
47
47
48
51
58
56
57
57
17
17
18
18
18
19
20
24
XCSF120C
XCSF120CP
XCSF120DP
XCSF240B
XCSF240C
XCSF240CP
XCSF240DP
XCSF240G
XCSF30B
XCSF30C
XCSF500C
XCSF500D
XCSF500G
XCSF565
XCSF85B
XCSF85C
XCSF85CP
XCSG2401C
XCSG2401D
XCSG2401G
XCSG2401R
XCSG481C
XCSG500C
XCSG500D
XCSG500G
XCSG720C
XCSG720D
XCSG960C
XCSG960D
XCSG960G
XCSL120C
XCSL240C
XCSL481C
XCSL85C
XCSR50U
XCSU070S
XCSU240S
XCSU500S
XCSUPS1
XCSUPS2
XCSW121B
XCSW121C
XCSW121DP
XCSW241B
XCSW241C
XCSW241DP
XCSW241G
XCSW481C
XCSW481D
XCSW481G
XF03DKBG5B
XF03DPCG5C
XF06DKBG5B
XF06DPCG5C
XF07TDVST2
XF100TDVST2
XF100TYT2
XF10TYG9
XF12DKBG5B
XF12DPCG5C
XF150TDS84C
XF16DKCG5B
XF16DPCG5C
XF16TDVST2
XF16TYT2
XF180TDS84C
XF200TDDS84C
XF20DKCG5B
XF20DPCG5C
XF20TYS9
XF25TYT2
XF300TDSS84C
XF30DKCS5B
XF30DPGS5C
XF30TDVST2
XF36TYT2
XF400TDSS84C
XF42TDVST2
XF50TYT2
XF55TDVST2
XF75TDVST2
XIF10PML
XIF10PMS
XIF14PML
XIF14PMS
XIF16PML
XIF16PMS
XIF16S7
XIF20PML
XIF20PMS
XIF26PML
XIF26PMS
XIF34PML
XIF34PMS
XIF40PML
XIF40PMS
XIF416LS7
160
PAGE
24
24
24
25
25
25
25
26
22
22
27
27
28
29
23
23
23
44
44
45
45
40
41
41
41
42
42
43
43
43
32
33
34
31
59
53
54
55
52
52
36
36
36
37
37
37
37
38
38
38
74
75
74
75
68
68
72
73
74
75
69
74
75
68
72
69
70
74
75
73
72
71
74
75
68
72
71
68
72
68
68
145
145
145
145
145
145
125
145
145
145
145
145
145
145
145
125
CODE
XIF416S7
XISD09FM
XISD09PF
XISD09PM
XISD15FM
XISD15PF
XISD15PM
XISD25FM
XISD25PF
XISD25PFL
XISD25PM
XISD25PML
XISD37FM
XISD37PF
XISD37PFL
XISD37PM
XISD37PML
XMBC2K
XNPNPNP
XO332060
XO332240
XR041E1A
XR041E24
XR041E24P
XR041E2A
XR041EAD
XR041S24F
XR041U24F
XR042E24
XR042E24P
XR042EAD
XR042S24
XR042T24
XR081E1A
XR081E24
XR081E24P
XR081E2A
XR081EAD
XR081S24F
XR081U24F
XR082E24
XR082E24P
XR082EAD
XR082S24
XR082T24
XR161E1A
XR161E24
XR161E24P
XR161E2A
XR161EAD
XR161S24F
XR161U24F
XR162E24
XR162E24P
XR162EAD
XR162S24
XR162T24
XRE1024D
XRE1824D
XRE2024D
XRF1012D
XRF1024D
XRF1824D
XRFA024D
XRFE16124
XRFE16224
XRFE8124
XRFE8224
XRMP081CM
XW000928
XW000929
XW000930
XW000931
XW000932
Z121017
Z121019
PAGE
125
142
142
142
142
142
142
142
142
143
142
143
142
142
143
142
143
60
99
130
130
120
112
113
121
114
139
115
116
117
118
137
138
120
112
113
121
114
139
115
116
117
118
137
138
120
112
113
121
114
139
115
116
117
118
137
138
101
101
102
102
101
101
101
128
128
126
127
120
95
95
95
96
96
157
157

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement