our catalogue
MPower UPS
LEADING POWER SOLUTIONS
t. 01420 82031
e. [email protected]
w. www.mpowerups.co.uk
10 years of uninterruptible power
MPower UPS
2
CONTENTS
4
5
6
7
8
9
10
11
12
13
14-15
16
17
18
Company Profile
Service Division
Sales Division
Inform Electronik
UPS Product Range
Guardian LCD Series
Informer Series
Sinus Premium LCD
Sinus LCD
DSP Flexipower
Green Triera Series
DSP Multipower Convertible
DSP Multipower Tower
Saver Plus DSP
19
20-21
22
23
24-25
26-27
28
29
30
31
32
33
34
35
Stark Series
Pyramid DSP Premium
Pyramid DSP T
Pyramid Plus
Modulera
Rack Cabinet
Info-STS Single Phase
Info-STS Three Phase
Frequency Converter
Regulators AVR
Regulators SVR
Medical Isolated Power Systems
Info PVI
Battery Cabinets
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
3
COMPANY PROFILE
MPower UPS was established in 2005 with the
aim of providing a high quality service, which
was honest and reliable and which met each
customer's diverse needs. Initially established
as a UPS maintenance provider, MPower quickly
diversified into selling and installing new UPS
systems due to customer demand.
Founders Michael Brooks and Farid Ahmed had
many years of experience in the UPS and Drives
industry between them and were able to offer
maintenance contracts on a wide range of UPS
systems. They were soon joined by an
experienced team of engineers giving a strong
UK wide coverage for emergency call outs,
maintenance and installations. As a result of their
experience they were successful in winning a
large contract in the nuclear industry.
By 2010 MPower had grown out of their Rake
offices in West Sussex and had purchased
bigger premises with offices and warehousing
facilities in Alton, Hampshire. It was also in 2010
that MPower first began entering into
discussions with Inform Electronic of Turkey who
were looking to enter the UK market at the same
time as MPower were actively looking for
a new manufacturer of high calibre UPS.
4
Following many meetings and visits to the
Inform premises in Istanbul, MPower were
so impressed with the quality of the UPS, the
attention to detail, the manufacturing facilities
and the commitment to continuous research
and development that we signed a contract
to become Inform's sole UK distributor. The
Inform premises in Istanbul are geared to
manufacturing and assembling all component
parts of the wide range of UPS meaning that
they are in complete control of design and
quality at each stage of manufacture. Recently,
Inform have been acquired by Legrand Group
who continue to invest heavily in research and
development with the aim of Inform products
being at the forefront of the UPS industry.
Inform UPS systems, static transfer switches
and battery cabinets have now been installed
in an ever growing range of sites across the UK.
Satisfied customers include headquarters
of international banks, London hotels,
Data Centres, Government Offices, Police
headquarters and the regional offices of a wide
range of UK and international companies.
SERVICE DIVISION
MPower UPS Ltd has the facilities to offer a full
service and maintenance package on UPS
and related equipment from a whole range
of manufacturers. This means we can have
trained engineers available for you 24 hours
a day, 7 days a week, 365 days a year.
We provide a complete solution for all your power
protection requirements as one of the UK's leading
suppliers and maintainers of emergency and back
up UPS power systems, emergency lighting, line
conditioners, diesel generators and battery banks.
Maintenance Contracts
All UPS systems need to be serviced regularly in order to
ensure they are operating correctly and that their batteries
are in good working order. A maintenance contract
ensures, as a minimum, yearly planned UPS maintenance
visits by a fully trained engineer, including a battery
inspection. Comprehensive contracts can also include all
parts and labour and guaranteed response times to site.
All contract customers have access to 24 hour emergency
call out facility and technical back up.
Emergency
Should you find yourself in an emergency with a failed
UPS, then we can assist even if we have not maintained
or installed your UPS. We have UPS and generators
available for hire as a short term solution and can have
them on site, installed and commissioned within 24 hours.
Battery Testing and Maintenance
During a service visit we undertake routine maintenance
tasks which include checking the open-circuit battery and
UPS float voltages, inspecting the physical condition
of terminals and connections and logging battery
impedance to predict the end of the batteries' useful life.
All works are carried out in line with our Environment
Policy as part of our commitment to reduce the impact
of pollution and the causes of climate change
wherever possible.
Battery Replacement and Disposal
Replacement and disposal of batteries is strictly governed
by regulations and must be carried out by licensed disposal
companies following prescribed methods.
We are experienced in ecologically acceptable removal
and disposal of UPS systems and consumable parts,
from batteries to complete power systems.
Generator Services
Standby generators provide vital back up when there is
prolonged power failure, however they are often left
unused for long periods of time. This means that they
require regular service to make sure they are ready for use
at the critical time. An alternative and cost effective option
is the hire of a generator from MPower UPS which can be
on site in a matter of hours
We can offer a full installation service for all our generator
systems, or alternatively we will be happy to provide your
appointed electrical contractor with any assistance that
they may require.
Emergency Lighting
The loss of mains electricity could be the result of a fire
or a power cut and the normal lighting supplies fail. This
may lead to sudden darkness and a possible danger to the
occupants, either through physical danger or panic.
MPower can supply and maintain emergency lighting
systems from all of the major manufacturers. Please contact
us with your exact requirements. Remember, if your battery
is old and failing and cannot support your emergency
lighting for the required time, it could cost lives.
Load Bank Testing
We can offer the security of knowing that your critical load
is fully protected and that your power protection solution
is fully optimised through providing a load bank test. We
can provide a mobile load bank to your site and a trained
engineer to carry out the tests. Full load bank testing can
simulate maximum load and fully tests the whole electrical
infrastructure, including switchgear, generators and auto
change over systems, identifying any possible risks
to your critical load. A written report is provided.
Power Factor Correction
Power Factor is a measure of how efficiently electricity
is being used. We can complete a site survey for you,
measure your power factor and suggest ways to improve
this. Effective power factor correction can lead to lower
energy bills due to increased efficiency in
electrical consumption.
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
5
SALES DIVISION
Working with our Customers
In order for us to fully understand your power
protection needs and therefore be able to offer
you the best advice, one of our team of skilled
engineers will visit your premises to conduct
a free site survey.
We will assess your critical power requirements
with regard to your present usage and to allow
for future growth. We will advise on location,
taking into account environmental and practical
restraints, and on electrical works which may
need to be carried out in preparation for the
installation of the new UPS. We will discuss run
time with you and advise on external battery
requirements, including configuration options.
We can advise on and supply all necessary
switchgear, monitoring software and generators.
We will help you decide on the best technical
solution to suit your needs as well as an
appropriate service plan to keep your UPS
system in sound working order.
Optional Extras
Switchgear
With all our systems we can supply appropriate switchgear
from various manufacturers made for your specific
requirements.
•
Battery Isolators for systems from 1kVA to 800kVA
•
Single UPS Bypass Panels for all systems. These
include all Single phase UPS, Three Phase Input
to Single Phase output UPS and Three Phase
Input Output UPS.
•
Multiple Bypass Panels are available for all the
above to parallel up to 9 UPS modules for high
reliability of power, or for high power ratings
of up to 6.4MVA.
Software
With all our systems we can supply appropriate software
to monitor the UPS units and control automatic shutdown
of servers via serial ports or over local area networks.
GSM Remote Monitoring
SD3 was originally developed for the security industry;
with the addition of an integral battery pack it is ideally
suited to UPS applications.
It can handle up to eight separate inputs for the UPS
or any other site system (e.g. door entry, generators etc.)
Text or speech messages may be sent to up to 10 numbers
via GSM and/or land line. Features include an internal
temperature sensor with an adjustable set point to provide
an additional over temperature alarm.
After Sales Service
Once your order is placed with us our project management
team will be in touch to co-ordinate delivery schedules and
all required works . They will be the single point of contact
for you throughout the installation process and can arrange
or liaise with external electrical contractors as required.
Our skilled engineers will be on site at a time to suit
yourselves to install and commission the UPS and provide
a final hand over to you. Your new Inform UPS is covered
by a two year warranty giving you peace of mind.
Help and support will never be far away and you can rest
assured that your critical systems are in safe hands.
6
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
INFORM ELECTRONIK
Inform believes that it is only through continuous
investment in research and development that
companies, involved in new technologies
and developing new products, will grow.
Tailor Made Solutions
If standard product specifications do not meet
customers' needs then Inform designs can be adapted
to a tailor-made solution.
The Inform product range is backed up by an
on-site research and development team, and
is constantly being updated to meet both
customers' needs and advances in technology.
The award winning team of experienced
engineers and technicians has been recognised
for their achievements in developing the new
generation, digital signal processor UPS, and
in 2005 they gained the 'Technology Innovation
and Creativity Reward' for the three phase
IGBT rectifier UPS.
Inform Machinery Park
Inform has an air-conditioned PCB assembling facility
at its plant, created especially for the production
of electrostatic sensitive assemblies. Furthermore,
in addition to its automatic assembly lines there are manual
assembly lines for producing transformers, coils and
connectors and other bespoke assemblies. There is the
capacity to produce 300 million components per annum.
Integrated Production
A step apart from other UPS manufacturers, Inform has
the ability to produce every part of its products on its own
premises, including circuit boards, mechanical parts, cables
and transformers. Final assembly and testing is also carried
out at the Inform factory complex in Istanbul, Turkey.
A Global Brand
Inform UPS is a global brand with customers all over the
world, extending from Europe to Asia, South America
to Africa and Australia.
This gives Inform the ability to control the quality
of every single part at every step of production.
The array of machines across the complex, for producing
standard and custom-made products includes computer
controlled CNC machines, plastic injection machines, fully
automatic painting machines and transformer winding
machines.
They draw on their long experience of power management
to provide a high quality, competitively priced power
solution to meet every need.
Inform UPS – The Informed Choice.
7
UPS PRODUCT RANGE
Line Interactive
VA:
Guardian LCD
Informer Series
600
800
1000
1500
2000
3000
✔
✔
✔
✔
✔
✔
✔
✔
✔
1
2
3
5
6
8
10
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
5
6
8
10
On line/Single Phase
kVA:
Sinus LCD
Sinus Premium LCD
DSP Flexipower
Green Triera
DSP Multipower Convertible
15
20
30
40
15
20
30
40
✔
✔
✔
✔
✔
✔
✔
✔
✔
140
160
On line/Three phase in Single phase out
kVA:
1
2
3
DSP Multipower Convertible
✔
✔
✔
DSP Flexipower
Green Triera
DSP Multipower Tower
Saver Plus DSP
Pyramid DSP
On line/ Three phase in-Three phase Out
kVA:
Stark Series
Pyramid DSP Premium
Pyramid DSP T
Pyramid Plus
10
15
20
30
40
60
80
100
120k
180
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
20
30
40
60
80
100
120k
140
160
180
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
200+
✔
✔
✔
Modular Three Phase in-Three Phase out
kVA:
Modulera
8
10
15
✔
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
200+
✔
MPower UPS
GUARDIAN LCD SERIES
Line Interactive Technology
600VA to 2000VA
•
•
•
•
•
•
•
•
•
•
•
Microprocessor controlled Line
Interactive Technology
Boost and Buck Automatic Voltage
Regulation (AVR)
LCD Display Panel
Advanced Battery Management (ABM)
Input Frequency auto sensing (50/60 Hz)
Auto restart after mains recovery
Short circuit and overload protection
Cold Start Function
USB Communication Interface and
Remote Monitoring Software
Modem/Phone line protection
Compact size and user friendly operation
Specification
MODEL
Capacity (VA)
GUARDIAN LCD 600AP
GUARDIAN LCD 800AP
GUARDIAN LCD 1000AP
GUARDIAN LCD 1500AP
GUARDIAN LCD 2000AP
600
800
1000
1500
2000
INPUT
Voltage
220V or 230V
Input Voltage Range
162 to 290VAC
Frequency
50 or 60 Hz (auto sensing)
OUTPUT
Power Factor
0.6
Voltage ( On battery )
220V or 230V ± 10%
Waveform ( On battery )
Simulated Sinewave
Frequency ( On battery )
50 or 60 Hz ± 1Hz
Voltage Regulation (AVR)
AVR automatically increases output voltage 15% above input voltage if -10% to -26% of nominal. AVR automatically decreases output voltage 15% below
input voltage if +10% to +22% of nominal.
Transfer Time
2 - 6 ms
Outlets
1pc Schuko & 1pc IEC C13
2pcs Schuko & 2pcs IEC C13
BATTERY
Type
Maintenance-free lead acid batteries
Recharge Time
6 hours ( to 90% of full capacity)
Voltage
Quantity
12VDC
24VDC
1x12V 7Ah
1x12V 9Ah
2x12V 7Ah
2x12V 9Ah
DISPLAY
LCD Display (optional)
Input & Output Voltage values, AC mode / Load Level / Battery Capacity Indicators
AUDIBLE ALARMS
Backup Mode , Low Battery, Overload, Fault
PROTECTION
Short Circuit, Overload, Battery Discharge, Overcharge, Phoneline
COMMUNICATION
USB Port
Software available as standard
ENVIRONMENT
Operating Temperature
0-40 °C
Humidity
0 to 90% non-condensing
Audible Noise at 1m
<40dBA
Protection class
IP20
PHYSICAL SPECIFICATIONS
Net Weight (kg)
Dimensions (mm) xDxH
4.35
4.7
101 x 298 x 142
7.8
149.3 x 353 x 162
10.1
10.5
158 x 380 x 198
STANDARDS
Standards
EN 62040-1-1 (Safety), EN 62040-2 (EMC)
9
INFORMER SERIES
Line Interactive Technology with Sinewave Output
1000VA/2000VA/3000VA
•
•
•
•
•
•
•
•
•
•
•
Pure sinewave output for any critical load
High Battery Charging Capacity
Extended back up time with additional
battery pack
Boost and buck Automatic Voltage
Regulation
Overload protection
Short circuit protection
Compact, lightweight and quiet
Discharge protection
Short recharge time
Fault alarms and State Warnings
Communication Port and Remote
Monitoring Software
Specification
MODEL
Capacity (VA)
INF1000
INF2000
INF3000
1000
2000
3000
INPUT
Voltage
220V / 230V ± 25%
Frequency
50 or 60Hz ± 5%
OUTPUT
Power Factor
0.6
Voltage (On battery)
220V / 230V ± 5%
Wave Form
Pure Sinewave
Frequency (On battery)
50 or 60 Hz ± 0.5%
AVR automatically increases output voltage 15% above input voltage if -9% to 25% of nominal.
AVR decreases output voltage 13% below input voltage if +9% to +25% of nominal
Voltage Regulation (AVR)
Transfer Time
2/4 ms.
Overload
Automatic shutdown if load exceeds 110% of nominal at 20 sec. and 125% at 2 sec.
Outlets
4pcs IEC C13
INTERNAL BATTERY
Type
Recharge Time (Hours)
Maintenance-free lead acid batteries
4
Voltage
Quantity
Back up Time on full load
5
6
4
5
24 VDC
4
48 VDC
5
48 VDC
2x12V 7Ah
2x12V 9Ah
2x12V 12Ah
4x12V 7Ah
4x12V 9Ah
4x12V 7Ah
4x12V 9Ah
4mins
7mins
10mins
4mins
7mins
3mins
5mins
Protection
Automatic Self-Test & Discharge Protection, Replace Battery Indicator
DISPLAY
LED Display
Back up, Overload, replace battery indicators
ALARMS
Line Failure, Battery Low, Overload and Fault
PROTECTION
Spike Protection (320 joule, 2 ms), Overload Protection, Short Circuit Protection
COMMUNICATION
Interface (Communication Ports)
RS 232 Standard
Software
Standard
ENVIRONMENT
Operating Temperature
0-40 °C
Humidity
0 to 90% non-condensing
Audible Noise at 1m
< 40 dBA
< 45 dBA
Protection Class
IP20
PHYSICAL SPECIFICATIONS
Tower Type
Net Weight (kg)
Dimensions (mm) WxDxH
19
20.5
22
28
30
32
135 x 430 x 390
135 x 470 x 390
483 x 450 x 132
483 x 512 x 132
19" Rack Mount Type
Dimensions (mm) WxDxH
STANDARDS
Standards
10
EN 62040-1-1 (Safety), EN 62040-2 (EMC)
34
SINUS PREMIUM LCD SERIES
On – Line Double Conversion Technology
1 phase in - 1 phase out
1kVA to 3kVA
•
•
•
•
•
•
•
•
•
•
•
•
Online double conversion technology
Input power factor correction PFC (>0.99 )
High output power factor ( PF : 0.9 )
Pure sinewave output
Wide input voltage and frequency range
Smart RS-232 communication port
Internal SNMP Slot Card Option
Management software compatible
Overload & short circuit protection
Cold start (DC power on)
Smart battery management
Compact size, lightweight & low noise
Specification
MODEL
Power(kVA)
INPUT
Voltage Range
Frequency
Power Factor
OUTPUT
Output Power Factor
Voltage
Voltage Regulation
Frequency ( Synchronized range )
Frequency ( Battery Mode )
Harmonic Distortion
Crest Factor
Output Waveform
SPS LCD 210
1
SPS LCD 220
2
SPS LCD 230
3
160VAC ~ 300VAC (@ 0% to 78% Load)
185VAC ~ 260VAC (@ 78% to 89% Load)
210VAC ~ 240VAC (@ 89% to 100% Load)
45Hz ~ 65Hz
≥0.99 (at full linear load)
0.9
220V / 230V / 240VAC
<±1% (until low battery warning signal)
3Hz or 1Hz (selectable)
50 / 60Hz ± 0.1%
<3% (at full linear load), <6% (@ full non-linear load)
3:1
Sinusoidal
100%-105% : Continuous
106%-120% for 30 seconds
Overload Capacity
121%-150% for 10 seconds
>150% : Transfer to Bypass
Line Mode efficiency
±>86%
±>87%
±>88%
Battery Mode efficiency
±>85%
±>86%
±>87%
Transfer Time (AC to DC)
0ms
Outlets
3pcs IEC C13 & 1pc Schuko
3pcs IEC C13 & 2pcs Schuko
6pcs IEC C13 & 2pcs Schuko
BATTERY
Type
Maintenance-free lead acid batteries
Recharge time
5 hours (to 80% of full capacity)
Voltage
24VDC
48VDC
72VDC
Internal Battery
2pcs 12V 7Ah
4pcs 12V 7Ah
6pcs 12V 9Ah
Cold Start
Yes
DISPLAY
LCD Display
Input/Output/Bypass Voltage, Input/Output/Bypass Frequency, Load %, Battery Voltage, Internal Temperature
ALARMS
Battery Mode, Battery Low, Overload, Failure Events
PROTECTION
Short Circuit
Bypass Mode: Fuse, Normal Mode: Output Breaker / Electronic Circuit, Battery Mode: Output Breaker / Electronic Circuit
Battery
Battery Discharge Management
EPO
UPS shuts down immediately
Over Temperature
Normal Mode: Transfers to Bypass Mode, Battery Mode: UPS shuts down immediately
COMMUNICATION
Interface(Communication Ports)
RS-232 Standard, Optional USB
Monitoring and Management Software
Standard
Options
Dry Contact Board, USB Board, SNMP Card
ENVIRONMENT
Temperature
0°C - 40°C
Humidity
0% - 90% (without condensation)
Noise Level (1m Distance)
<50dBA
Protection Class
IP20
PHYSICAL SPECIFICATIONS
Net Weight (kg)
12
22
27
Dimensions(mm) WxDxH
144 x 360 x 220
152 x 438 x 322
190 x 438 x 322
STANDARDS
Standards
EN 62040-1-1 (Safety), EN 62040-2 (EMC)
ACCESSORIES
Optional
Internal & External SNMP, Dry Contact Board, Additional Charging Board
11
SINUS LCD SERIES
On-Line Double Conversion Technology
1 phase in - 1 phase out
1kVA to 3kVA (Tower & Rack Convertible)
•
•
•
•
•
•
•
•
•
•
On-line double conversion technology
Real Digital Signal Processor (DSP)
Controller
Power factor correction PFC (>0.99)
User friendly LCD display
Programmable power outlets to allow
load shedding
Wide input voltage and frequency range
Can be configured as 50/60Hz
Frequency Converter from LCD Panel
Smart communication port and SNMP
management capability
Hot Swappable Battery
Emergency shutdown control through EPO
•
•
•
•
•
•
•
Overload and short circuit protection
Powerful Built-in Charger
Extended back up time with additional
battery cabinets
Cold start (DC power on)
Genius battery management (GBM)
RS232, USB and SNMP can be activated
simultaneously
Compact, lightweight and low noise
Specification
MODEL
Power(kVA)
INPUT
Voltage
Frequency
Power Factor
OUTPUT
Power Factor
Voltage
Voltage Regulation
Frequency
Frequency Regulation
Harmonic Distortion
Crest Factor
Output Waveform
Overload Capacity
SS LCD 210
1
SS LCD 220
2
SS LCD 230
3
160VAC - 288VAC
50/60 Hz ±5% (Auto Sensing)
>99%
0.8
220 / 230 / 240VAC
±%1
50/60 Hz
± 0,1%
<3%
3:1
Sinusoidal
100%-120% for 30 seconds
120%-150% for 10seconds
Whole efficiency
>85%
>88%
Transfer Time
0ms
Outlets
6pcs IEC C13
4pcs IEC C13
INTERNAL BATTERY
Type
Maintenance-free lead acid batteries
Recharge Time
3 hours (to 90% of full capacity)
Voltage
36VDC
72VDC
Internal Battery
3pcs 12V 7Ah
6pcs 12V 7Ah
6pcs 12V 9Ah
Built in max. Charge Current
1.8A
2.1A
2.7A
Back Up Time
Full Load
5 min
4 min
Half Load
12 min
10 min
Cold Start
YES
DISPLAY
LED Display
Utility or Bypass, Battery Low, Battery Abnormal, Overload, Site Wiring Fault, Service Mode, UPS Off, UPS Abnormal
LCD Display
Input /Output Voltage and Frequency Values, Load %, Battery Voltage, Internal Temperature
ALARMS
Line Failure, Battery Low, Over Load, Failure Events
PROTECTION
Short Circuit, Over Temperature, Overload, High Voltage, Battery Low, EPO
COMMUNICATION
Interface
RS232 and USB
Monitoring and Management Software
Standard
ENVIRONMENT
Temperature
0°C - 40°C
Humidity
0% - 90% (without condensation)
Noise Level (1m Distance)
<50dBA
Protection Class
IP 20
PHYSICAL SPECIFICATIONS
Net Weight (kg)
16
29.5
30
Dimensions(mm) WxHxD
440 x 88 x 405
440 x 88 x 650
440 x 88 x 650
STANDARDS
Standards
EN 62040-1-1 (Safety), EN 62040-2 (EMC)
ACCESSORIES
Optional
Internal & External SNMP, Dry Contact Board, External Manual Bypass, Rail Kit, External Battery Connection Cable
12
DSP FLEXIPOWER SERIES
On-Line Double ConversionTechnology
1 Phase in / 1 Phase out from 3kVA to 10kVA
3 Phase in / 1 Phase out 10kVA
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Real Digital Signal Processor (DSP) Controller
Power Factor Correction
High output power factor
Parallel redundant operation up to 4 units (excluding 3kVA)
High performance with the PWM Sinewave topology
Cold start function
Intelligent Battery Management System extends
the life time of batteries
Overload, Overheat & Short Circuit Protection
Emergency Shutdown Control through EPO
User Friendly Multi-Functional LED/LCD Display Panel
Energy Saving Mode (ECOMODE)
RS232 Communication Port & Management Software
Internal SNMP, Relay contact card and RS485 card options
Extended Back up time with External Battery Cabinet
Specification
MODEL
Power (kVA)
Power (kW)
INPUT
Phase Configuration
Nominal Voltage
Minimum Voltage
Maximum Voltage
Frequency
Power Factor
OUTPUT
Power Factor
Phase Configuration
Nominal Voltage
Wave Form
Total Harmonic Distortion at 100% linear load
Frequency
Frequency Tolerance (free running)
Static Voltage Regulation (0%-100% load)
Crest Factor
Transfer Time
Overload
FP1103
3
2.4
FP1105
5
4.5
FP1106
6
5.4
FP1108
8
7.2
1Ph + N + PE
220V/230/240V
160
288
± 5Hz
FP1110
10
9
FP3110
10
9
3Ph + N + PE
380V/400V/415V
320V
485V
180
280
45-65 Hz
0.99
0.8
60 min @ (100%-110%)
10 min @ (110%-125%)
0.9
1Ph + N + PE
220V / 230 / 240V (adjustable)
Pure Sine Wave
<3%
50Hz or 60Hz (adjustable)
±0,2 %
<1%
3:1
0sec
2min @ (100%-120%)
30sec @ (120%-150%)
Transfers to Bypass @150%
≥92%
Total Efficiency
≥90%
BATTERY
Type
Maintenance-free lead acid batteries
Recharge Time (for Internal Battery)
4-6h up to 90%
Quantity per String
6pcs 12V Batteries
20 pcs 12V Batteries
Voltage
72VDC
240VDC
Internal Batteries (Optional)
7Ah or 9Ah
Cold Start
Yes
DISPLAY
LED + LCD Display
Line Mode, Back up Mode, Eco Mode, Bypass Supply, Battery Low, Battery Fault/Disconnected, Overload, UPS Fault, Interruption during transfer
LCD Display
Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load %, Battery Voltage, Internal Temperature
Self Diagnostics
Power on self test and continuous self diagnostics
PROTECTION
Overload Protection
Transfers to bypass on overload
Short Circuit Protection
Current limits and internal fuses
COMMUNICATION
Interface (Communication ports)
Standard RS232 port and optional RS485, Internal SNMP, Volt free relay contact card
ENVIRONMENT
Operating Temperature
0˚C - 40˚C
Proposed Temp. to extend battery life
20˚C - 25˚C
Humidity
up to 90% ( non-condensing )
Audible Noise at 1 m
<50 dB
<52 dB
Protection Class
IP20
PHYSICAL SPECIFICATIONS
Dimensions(mm) (HxWxD)
449x226x454
585x255x741
Weight - without battery ( kg )
19
30
38
45
STANDARDS
Standards
EN62040-1-1 (Safety); EN62040-2 (EMC)
ACCESSORIES
Optional
Internal or External SNMP, Relay Contact Card, Monitoring and Management Software, Internal Battery Holder Apparatus, Additional Charging Set
13
GREEN TRIERA SERIES
On-Line Double Conversion 3 Level Inverter Technology
1 Phase in / 1 Phase out 3kVA to 10kVA
3 Phase in / 1 Phase out 10kVA
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
14
On-line Double conversion 3 Level Inverter
Technology
Real Digital Signal Processor (DSP)
Controlled IGBT Technology
High AC-AC Efficiency (94%)
High Output power factor (0.9)
Increased Input Power Factor (p.f. > 0.99)
Low Input Current THD (<6%)
Low Output Voltage THD (<1.5%)
Wide input voltage range (90 V - 270 V)
Cold Start & Soft Start Features
Facility to start up from mains supply without
batteries
Intelligent battery management system extends
the life time of batteries
Transformerless design
Compact
Temperature controlled Smart fan speed
Multi-Functional LCD display (ability to adjust or
calibrate the UPS without the need for software )
Advanced LCD Panel Menu (ability to monitor 15
different parameters)
Event Log displaying up to 500 events
Configurable as a 50/60Hz Frequency Converter
from the LCD Panel
Advanced communication possible through
RS232 port
Management and monitoring software available
for all operating systems
SNMP, Modbus, USB Card, Volt Free Relay Contact
Card & EPO Card options
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
Specification
MODEL
GTR1103
GTR1105
GTR1106
GTR1108
GTR1110
GTR3110
Power (kVA)
3
5
6
8
10
10
Power (kW)
2.7
4.5
5.4
7.2
9
9
INPUT
Nominal Voltage
220V/230V/240V
380V/400V/415V
Minimum Voltage (at half load)
90V
155V
Minimum Voltage (at full load)
180V
320
Maximum Voltage
270V
467
Frequency
45-65 Hz
Power Factor
>0,99
>0,95
Input Current Harmonics
<6%
<25%
OUTPUT
Power factor
0.9
Nominal Voltage
208V to 242V adjustable
Voltage Tolerance
Nominal current @220V
±1%
13.6A
23A
27A
36.4A
Wave Form
45.5A
45.5A
Pure Sine Wave
Total Harmonic Distortion
at 100% linear load
<1.5%
<2%
at 100% non-linear load
<3.5%
<4%
Frequency
50Hz or 60Hz (adjustable from LCD Panel)
Frequency Tolerance(battery operation)
0.005%
Static Voltage Regulation (0%-100% load)
1%
Dynamic Voltage Regulation (0%-100% load)
5%
Crest Factor
3:1
Overload
100% to 125% overload
10 min
125% to 150% overload
1 min
Overall Efficiency (AC-AC)
94%
Greenmode ( Ecomode ) Efficiency
>98%
BATTERY
Type
Maintenance-free lead acid batteries
Recharge Time
Quantity per String
Voltage
6h - 8h
14pcs 12V Batt
20pcs 12V Batteries
168VDC
240VDC
Internal Batteries (Optional)
7Ah, 9Ah or 12Ah
Cold Start
Yes
DISPLAY PANEL
Load %, Input/Output/Bypass Voltages, Output Power (W & VA), Output Current
Output p.f., Battery +/- Voltage Values, Input/Output Frequency, DC Bus +/- Voltages,
Remaining Back Up Time, Internal Temperature, Heatsink Temperature
LCD Display
Audible and Visual Alarm Warning
41 different Alarm Messages
BY-PASS
Voltage Tolerance
±10%
Frequency Tolerance
3Hz (adjustable from LCD panel between 0.5Hz to 5Hz)
Transfer Time
0 ms
Overload Capability
up to 175%
PROTECTION
Overload Protection
Transfers to bypass on overload
Short Circuit Protection
Current limits and internal fuses
COMMUNICATION
Interface (Communication Ports)
RS232 (standard), SNMP, Modbus and USB (optional)
Relay Contact Port Option
Alarm relays programmable from display panel
ENVIRONMENT
Operating Temperature
0˚C - 40˚C
Storage Temperature
-15˚C to +55˚C
Proposed Temp. to extend battery life
20 - 25˚C
Humidity
< 95%
Maximum Altitude
1000m
Audible Noise ( from 1m distance )
<50 dB
Protection Class
<55 dB
IP 20
PHYSICAL SPECIFICATIONS
Dimensions (mm) (WxDxH)
Net Weight - without battery (kg)
272 x 740 x 758
32
33
34
43.5
44
47
STANDARDS
Standards
EN 62040-1-1 (safety), EN 62040-2 (EMC), EN 62040-3 (Performance)
ACCESSORIES
Optional
Internal&External SNMP, Relay Contact Board, Monitoring and Management Software, Internal Battery Holder Apparatus, Additional
External Charging Set
15
DSP MULTIPOWER CONVERTIBLE SERIES
On-Line Double Conversion Technology
1 Phase in / 1 Phase out from 5kVA to 10kVA,
3 Phase in / 1 Phase out from 10 to 20kVA
(Tower & Rack Convertible)
•
•
•
•
•
•
•
•
•
•
•
•
•
On-line double conversion technology
Real Digital Signal Processor (DSP) Controller
Parallel redundant operation up to 4 units
Input Power Factor Correction PFC
Transformerless Design
High Performance with PWM Sinewave Topology
Cold Start Function
Overload, Overheat & Short Circuit Protection
User Friendly, Multi-Functional LED/LCD Display Panel
Energy Saving Mode (ECOMODE)
Smart Fan Speed Regulation with temperature control
RS232 Communication Port & Management Software
Internal SNMP, RELAY contact, RS485 card options
Specification
MODEL
Power (kVA)
Power (kW)
INPUT
Phase Configuration
Nominal Voltage
Minimum Voltage ( at Half load )
Minimum Voltage ( at Full load )
Maximum Voltage
Frequency
Power Factor
OUTPUT
Power Factor
Phase Configuration
Nominal Voltage
Wave Form
Total Harmonic Distortion at 100% linear load
at 100% non-linear load
Frequency
Frequency Tolerance (free running)
Frequency Synchronized Range
Static Voltage Regulation (0%-100% load)
Crest Factor
Transfer Time
DSPMP-1105
5
4.5
DSPMP-1106
6
5.4
DSPMP-1110
10
9
DSPMP-3110
10
9
1Ph + N + PE (Hardwire)
220VAC/230VAC/240VAC
160VAC
180VAC
280VAC
DSPMP-3115
15
13.5
DSPMP-3120
20
18
3Ph + N + PE (Hardwire)
380VAC/400VAC /415VAC
277VAC
312VAC
485VAC
45-65 Hz
0.99
Overload
Total Efficiency
up to 90%
Greenmode Efficiency
Outlets
BATTERY
Type
Recharge Time
0.95
0.9
1Ph + N + PE (Hardwire)
220VAC / 230VAC / 240VAC
Pure Sine Wave
<3%
<5%
50Hz or 60Hz (adjustable)
±0,1 %
±1Hz or ±3Hz ( selectable )
<1%
3
0sec
Up to 10min. @100%~120%
Up to 1min. @120%~150%
Transfer to bypass @ >150%
up to 91%
≥97%
Additional external socket boxes available
up to 93%
Maintenance-free lead acid batteries
4-6h up to 90%
192VDC for 16 pcs
240VDC
240VDC for 20 pcs
Quantity per string
20 pcs 12V Batteries
Internal batteries
20 pcs 12V 4.5Ah ( internal battery version only )
N/A
Built in max. charge current
1.6A
4A
Cold Start
Yes
DISPLAY
LED + LCD Display
Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Fail/Disconnected, Overload, Transferring with Interruption and UPS Fault
LCD display
Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage & Internal Temperature.
Self Diagnostics
Power on self test and continuous self diagnostics
Audible and Visual Alarms
Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions
PROTECTION
Overload Protection
Transfers to bypass on overload
Short Circuit Protection
Current limits and internal fuses
COMMUNICATION
Interface (Communication ports)
Standard RS232 port and optional RS485, Internal SNMP, Volt free relay contact Card
Monitoring and Management Software
Supplied with UPS as standard
ENVIRONMENT
Operating Temperature
0˚C - 40˚C
Proposed Temp. to extend battery life
20˚C - 25˚C
Humidity
up to 90% ( non-condensing )
Audible Noise at 1 m
<50 dB
<60 dB
Protection Class
IP20
PHYSICAL SPECIFICATIONS ( tower position )
Net Weight ( power module)
25kg
26kg
28kg
36kg
Net Weight (with internal batteries)
53kg
N/A
N/A
Dimensions(mm) (HxWxD)-power module
440x88x680
440x132x680
440x220x720
Dimensions(mm) (HxWxD)- w/battery vers.
440x176x680
N/A
N/A
STANDARDS
Standards
EN62040-1-1 (Safety); EN62040-2 (EMC); EN62040-3 (Performance); EN60950-1
ACCESSORIES
Optional
Internal&External SNMP, Relay Contact Board, External Manual Bypass, Rail Kit, External Battery Connection Cable, External Socket Box, External Additional Charging Board
Voltage
16
DSP MULTIPOWER TOWER SERIES
Online Double Conversion Technology
3Phase in / 1Phase out – 15kVA & 20kVA
•
•
•
•
•
•
•
•
•
•
•
•
On-Line Double Conversion Technology
Real Digital Signal Processor (DSP) Controller
Parallel redundant operation up to 4 units
High Input Power Factor (0.95)
Transformerless Design
Cold Start Function
Overload, Overheat & Short Circuit Protection
User Friendly Multi-Functional LED/LCD
Display Panel
Energy Saving Mode (GREEN MODE)
Intelligent Battery Management System
RS232 Communication Port & Management
Software
SNMP, Relay Contact, RS485 and USB
card options
Specification
MODEL
DSPMP-3115T
DSPMP-3120T
Power (kVA)
15
20
Power (kW)
13.5
18
INPUT
Phase Configuration
3Ph + N + PE (Hardwire)
Nominal Voltage
380VAC/400VAC /415VAC
Minimum Voltage ( at 75% Load )
277VAC
Maximum Voltage
485VAC
Frequency
45-65 Hz
Power Factor (@linear load )
0.95
OUTPUT
Power Factor
0.9
Phase Configuration
1Ph + N + PE (Hardwire)
Nominal Voltage
220VAC/230VAC/240VAC
Wave Form
Pure Sine Wave
Total Harmonic Distortion at 0 to 100% linear load
<3%
Frequency
50Hz or 60Hz (adjustable)
Frequency Tolerance (free running)
±0.2%
Frequency Synchronized Range
±1Hz or ±3Hz ( selectable )
Voltage Regulation
±2%
Crest Factor
3
Transfer Time
0sec
Total Efficiency
> 91%
Greenmode Efficiency
> 95%
BATTERY
Type
Maintenance-free lead acid batteries
Voltage
240VDC
Quantity per string
20pcs 12V Batteries
Built in max. Charge Current
4A
DISPLAY
LED + LCD Display
LCD display
Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Fail/Disconnected, Overload, Transferring with Interruption and UPS Fault
Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature.
Self Diagnostics
Power on self test and continuous self diagnostics
Audible and Visual Alarms
Line Failure, Battery Low, Transfer to Bypass, System Fault
COMMUNICATION
Interface (Communication ports)
Standard RS232 port and optional RS485, Internal SNMP, Volt Free Relay Cards
Monitoring and Management Software
Supplied as standard
ENVIRONMENT
Operating Temperature
0 ˚C - 40 ˚C
Proposed Temp. to extend battery life
20 - 25 ˚C
Humidity
up to 90% (non-condensing)
Audible Noise at 1 m
<60 dB
Protection Class
IP 20
PHYSICAL SPECIFICATIONS
Net Weight
Dimensions(mm) (HxWxD)
60kg
62kg
290x650x770
STANDARDS
Standards
EN62040-1-1 (Safety); EN62040-2 (EMC); EN62040-3 (Performance); EN60950-1
ACCESSORIES
Optional
Internal&External SNMP, Relay Contact Board, External Manual Bypass, External Battery Connection Cable, External Additional Charging Board
17
SAVER PLUS DSP SERIES
On-Line Double Conversion Technology
3 phase in / 1 phase out 15 and 20 kVA
•
•
•
•
•
•
•
•
•
•
•
On-line double conversion technology
Real Digital Signal Processor (DSP) controlled,
IGBT technology
Wide input voltage range (140V-480V)
Input Power Factor Correction PFC (>0.97)
Intelligent Battery Management System
extends the life time of batteries
Transformerless Design
Compact
Manual Bypass
LCD display
RS 232 and relay interface
Management and monitoring software
available for all operating systems and SNMP
Specification
MODEL
SD3115
SD3120
Power
15kVA
20kVA
INPUT
Nominal Voltage
380 V / 400V / 415V 3Phase, N
Minimum Voltage
140V 3Phase, N
Minimum Voltage (at full load)
260V 3Phase, N
Maximum Voltage
480V 3Phase, N
Frequency
50 - 60Hz (45 to 65 Hz)
Nominal Current
17.4 A / phase
23.3 A / phase
Maximum Current
53 A peak / phase
71 A peak / phase
Power Factor
>0.97
OUTPUT
Power Factor
0.7
Nominal Voltage
220V / 230V (adjustable)
Wave Form
Sinus
Total Harmonic Distortion
< 3%
Frequency
50Hz or 60Hz (adjustable)
Voltage Regulation (Static)
1%
Crest Factor
3
Overload
> 30s (at 150% load)
Total Efficiency
> 91%
BATTERY
Type
Maintenance-free lead acid batteries
Quantity per string
32pcs 12V Batteries
Voltage
384VDC
Recharge Time for Internal Batteries
<4h
Discharge Current Wave
<10%
Internal Batteries (Optional)
12Ah
Warning
Audible Buzzer through to the end of Battery Discharge
DISPLAY
LED Panel
Line, Bypass, Battery, Inverter, Overload, Fault Indicators
LCD Panel
Load%, Battery Temperature, Input, Output & Battery Voltages, Output Frequency
STATIC BY-PASS
Voltage Tolerance
10% (adjustable)
Frequency Tolerance
3Hz (adjustable)
Transfer Time
0 ms
PROTECTION
Protections
Overload Protection, Short Circuit Protection, High Temperature, Over Voltage, Over Current
COMMUNICATION INTERFACE
Interface (Communication Ports)
RS 232
Dry Contact Signals
UPS shutdown, mains failure, low battery, by-pass active, summary alarm
ENVIRONMENT
Temperature
0 - 40˚C
Suggested Temp. to extend battery life
20 - 25˚C
Humidity
< 95%
Audible Noise (from 1m distance)
< 55dB
Protection Class
IP 20
PHYSICAL SPECIFICATIONS
Net Weight - without battery (kg)
125
130
Dimensions (mm) (WxDxH)
270x730x780
430x820x970
STANDARDS
Standards
EN 62040-1-1 (Safety), EN 62040-2 (EMC)
ACCESSORIES
Optional
External SNMP, Monitoring and Management Software, Remote Monitoring Panel, Additional Charging Set, Internal Galvanic Isolation Transformer
18
STARK SERIES
On-Line Double Conversion Technology, DSP Controlled IGBT Rectifier UPS
3 phase in / 3 phase out from 10 to 40kVA
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Real Digital Signal Processor (DSP) controlled transformerless design
High Output Power Factor (0.9)
High Efficiency (up to 93%)
Wide Input Voltage Range
Cold Start Capability
Increased Efficiency with Eco Mode Operation
Parallel Redundant Operation up to 4 Units
Common Battery Application with Parallel Systems
Static and Manual Bypass Built-in
User Friendly LCD/LED Display Panel
Remaining back up time indication on the LCD Display panel
EPO (Emergency Power Off) Function
Short Circuit, Overload, Over temperature, Deep Discharge protection
USB, RS232, RS485 & RELAY Contact Communication Ports
Compact dimension with internal battery placement options
Specification
MODEL
Power (kVA)
Power (kW)
INPUT
Phase Configuration
Nominal Voltage
Voltage Range (Full Load)
Voltage Range (Half Load)
Frequency
Power Factor
Total Harmonic Distortion (THDi)
OUTPUT
Power Factor
Phase Configuration
Nominal Voltage
Wave Form
Total Harmonic Distortion
at 100% load
Frequency
Frequency Tolerance(free running)
Static Voltage Regulation (0%-100% load)
Crest Factor
Transfer Time
Overload
ST3310
10
9
ST3315
15
13.5
ST3320
20
18
ST3330
30
27
ST3340
40
36
3Ph + N + PE
380 / 400 / 415 VAC
304~478
323~478
208~478
50/60 Hz ±10% (auto sensing)
0.99
3%
0.9
3Ph + N + PE
380 / 400 / 415 VAC (adjustable)
Pure Sine Wave
≤2% with linear load
≤5% with non linear load
50Hz or 60Hz (adjustable)
(50/60±0.2%)Hz @ Battery Operation
<1%
3:1
0sec
60 min @ (100%-110%)
10 min @ (110%-125%)
1 min @ (125%-150%)
Transfers to Bypass @ ≥150% (On-line Mode)
Up to 93%
Total Efficiency
BATTERY
Type
Maintenance-free lead acid batteries
Recharge Time (for Internal Battery)
4-6h up to 90%
Quantity per String
16/18/20pcs
32/34/36/38/40pcs
Internal Battery Type
7Ah, 9Ah
None
Internal Battery Quantity
Up to 40pcs
Up to 60pcs
None
Standard Charging Current
1,.5A
2.7A
4A
10A
Max Charging Current
10A
Cold Start
Yes
DISPLAY
Operation Modes
Normal Mode, Back up Mode, Eco Mode, Parallel Mode
LCD display
Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load %, Battery Voltage, Battery Current, Autonomy Time, Temperature
PROTECTION
Overload, Over Voltage, Overheat, Short Circuit, Low Battery
COMMUNICATION
Interface (Communication ports)
USB, RS485, 3pcs RELAY Contact Signal,
Dry Contact ( standard )
UPS Battery Low, AC Power Failure, Shut down UPS
ENVIRONMENT
Operating Temperature
0˚C - 40˚C
Proposed Temp. to extend battery life
20˚C - 25˚C
Humidity
up to 95% (non-condensing)
Max. Altitude without derating
up to 1000 meters
Audible Noise at 1 m
<55 dB
<58 dB
Protection Class
IP20
PHYSICAL SPECIFICATIONS
Dimensions(mm) (WxDxH)
250 x 828 x 868
Weight - without battery ( kg )
65
70
71
93
73
STANDARDS
Standards
EN62040-1-1 (Safety); EN62040-2 (EMC)
ACCESSORIES
Optional
SNMP & Additional Relay Board
19
PYRAMID
INFORMER
DSP
SERIES
PREMIUM SERIES
On-Line
Line
Interactive
“Double
Technology
Conversion”
with
Technology,
Sinewave Output
1000VA/2000VA/3000VA
DSP
Controlled IGBT Rectifier
(Tower
UPS& Rack Models)
3phase in / 3phase out 10 to 300kVA
•
Pure sinewave output for any critical load
••
Graphical
Touch
ScreenCapacity
Front Display Panel
High Battery
Charging
••
IGBT
Rectifier
Extended
back up time with additional
•
Real
Digital
battery packSignal Processor (DSP) controlled
transformerless
design Voltage
•
Boost
and buck Automatic
•
Input
Power
Factor
Correction PFC( >0.99 )
Regulation
••
Low
Total Harmonic
Overload
protectionDistortion Level ( THDi ≤ 4% )
••
High
Efficiency
Short circuit protection
••
Wide
Inputlightweight
Voltage Range
Compact,
and quiet
••
Generator
Compatible
Discharge protection Operation
••
Evolution
and redundancy
guaranteed by on site
Short recharge
time
Modular
Parallel
Systems
•
Fault alarms and State Warnings
••
Intelligent
batteryPort
management
system extends
Communication
and Remote
battery
life
Monitoring Software
••
Static
and Manual
Bypass
Rack Version
available
•
EPO (Emergency Power Off)
•
SNMP option for communicating with computer
and LAN
•
Extended run time options
•
Low installation and operating costs
Accessories
Communication
•
Remote Monitoring Panel &25m Cable For Remote Panel
•
UPSMAN (Management Software)
•
Multiserver Shutdown Licence
•
Internal SNMP kit
•
External Adapter
SNMP Adapter Net Agent Mini DT 522
SNMP Adapter CS121BL
Other
•
•
•
20
Separate bypass supply option
Parallel Kit
Drawer Type Internal Battery Shelves 10 - 30kVA
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
Specification
MODEL
Output power ( kVA)
Nominal Active Power ( kW )
PDSP-P
33010
PDSP-P
33015
PDSP-P
33020
PDSP-P
33030
PDSP-P
33040
PDSP-P
33060
PDSP-P
33080
PDSP-P
33100
PDSP-P
33120
PDSP-P
33160
PDSP-P
33200
PDSP-P
33250
10
15
20
30
40
60
80
100
120
160
200
250
PDSP-P
33300
300
9
13.5
18
27
36
54
72
90
108
144
180
225
270
INPUT
Number of phases
3Ph+N+PE
Nominal Voltage ( 3ph Phase to Phase )
380V/400V/415V
Voltage range
(-15)% (+27)%
Voltage range (64% load)
(-45)% (+27)%
Voltage range (42% load)
(-64)% (+27)%
Nominal Frequency ( Hz )
50 or 60
Frequency range for online operation
±10%
Input Current THD
≤4%
Input Power Factor
0.99
OUTPUT
Power factor
0.9
Number of phases
3Ph+N+PE
Voltage ( 3ph Phase to Phase )
380V/400V/415V
Static Voltage Regulation at %100
Linear Load ( online&battery mode )
<1%
Voltage THD at rated linear load
<3%
Crest factor
3:1
Frequency (Hz)
50 or 60
Free Running Frequency (Hz)
± 0.01%
125% for 10 minutes
Overload
150% for 1 minute
Efficiency
up to 94%
BATTERY
Type
Maintenance-free Lead Acid Batteries
Quantity (pcs )
62 ( 2*31 )
Battery Protection
60 ( 2*30 )
Deep Discharge Protection with Auto Cut off
Battery Test
Standard ( Automatic and Manual )
DISPLAY
Graphical Flow Diagram for Line, Rectifier, Bypass, Battery, Inverter and Load
3.5" Graphical Touch Screen
Input & Output Frequency, Voltage & Current, Load Power Factor, Load%, Load Active & Apparent Power,
Bypass Voltage & Frequency, Battery Voltage, Current & Temperature, Autonomy Time (min),
STATIC BYPASS
Number of phases
3Ph+N+PE
Voltage Range for bypass operation
± 10%
Frequency Range for bypass operation (Hz)
± 6% ( Configurable )
COMMUNICATION
Interface (Communication Ports )
Relay Contact Signals (Adjustable)
RS232, RS485 (ModBus)
Programmable 4 Relay Contacts to any of following signals ; General Alarm, Input Failure, Battery Failure, Output Failure, Bypass Acvite, Output Overload, High Temperature
Others
EPO, Generator Interface
ENVIRONMENT
Storage Temperature Range (°C )
-25 to +55 ( 15 to 40 recomended for longer battery life time )
Operating Temperature Range (°C )
0 to 40 ( 20 to 25 recomended for longer battery life time )
Relative Humidity Range
0-95% ( non-condensing )
Maximum Altitude without derating (m)
1000
Protection Level
IP20
Audible Noise Level from 1m (dBA)
50
52
55
58
60
68
72
77
100
120
160
200
78
78
250
300
PHYSICAL SPECIFICATIONS
Output power ( kVA)
10
Dimensions WxDxH (cm)
Weight (kg)
15
20
30
40 x 78 x 107
100
114
116
40
52 x 90 x 130
122
180
60
80
67 x 73 x 163
253
285
85 x 78 x 182
405
98 x 87 x 195
522
570
134 x 108 x 195
735
750
800
STANDARDS
Standards
EN 62040-1-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (VFI-SS-111)
21
PYRAMID DSP-T SERIES
On-Line Double Conversion Technology,
IGBT Rectifier UPS with Built in Isolation Transformer
3 phase in / 3 phase out from 10 to 300 kVA
•
•
•
•
•
•
•
•
•
•
•
•
•
Real Digital Signal Processor (DSP) controlled
Built in Output Isolation Transformer
Input Power Factor Correction PFC (>0.99)
Wide Input Voltage Range
Generator Compatible Operation
Parallel ready for future proofing
Intelligent battery management system extends battery life
Synchronization Capability from external sources
Static and Manual Bypass
SNMP option for communication with computer and LAN
Extended run time options
Low installation and operating costs
EPO (Emergency Power Off)
Specification
MODEL
Output Power ( kVA )
Active Power ( kW )
PDSP-T
33010
PDSP-T
33015
PDSP-T
33020
PDSP-T
33030
PDSP-T
33040
PDSP-T
33060
PDSP-T
33080
PDSP-T
33100
PDSP-T
33120
PDSP-T
33160
PDSP-T
33200
PDSP-T
33250
PDSP-T
33300
10
15
20
30
40
60
80
100
120
160
200
250
300
8
12
16
24
32
48
64
80
96
128
160
200
240
INPUT
Number of Phases
3Ph + N + PE
Nominal Voltage (Ph-Ph)
380V/400V/415V
Voltage range (100% load)
-15% ~ +27%
Voltage range (64% load)
-45% ~ +27%
Voltage range (42% load)
-64% ~ +27%
Nominal Frequency (Hz)
50 or 60 ±10%
Input Power Factor
0.99
OUTPUT
Output Power factor
0.8
Number of Phases
3Ph + N + PE
Voltage
380V/400V/415V
Static Voltage Regulation at 100%
Linear Load ( online&battery mode )
<1%
Voltage THD at rated linear load
<1.5%
Crest factor
3:1
Free Running Frequency (Hz)
50 or 60 ± 0.01%
Overload
125% for 10 minutes; 150% for 1 minute
Efficiency
≥ 90% (**)
STATIC BYPASS
Voltage Range
380V / 400V (Ph-Ph) ± 10%
Frequency Range
for bypass operation (Hz)
±6% (Adjustable)
BATTERY
Type
Maintenance-free lead acid batteries
Battery Quantity (pcs)
54 (2 x 27)
Battery Protection
Deep discharge protection with auto cut off
Battery Test
Standard (Automatic and Manual)
COMMUNICATION
Interface (Communication Ports)
RS232 & RS422
RELAY Contact Signals
AC Failure, Battery Under Voltage, Bypass Operation, Output Failure
Others
EPO, Generator Interface
ENVIRONMENT
Storage Temperature Range (°C)
-25 to +55 (15 to 40 recommended for longer battery life)
Operating Temperature Range (°C)
0 to 40 (20 to 25 recommended for longer battery life)
Relative Humidity Range
Up to 95% (non-condensing)
Maximum Altitude
without derating (m)
< 1000
Protection Class
IP20
PHYSICAL SPECIFICATIONS
Dimensions (wxdxh ) cm
Weight (kg)
40 x 78 x 107
235
238
52 x 90 x 130
273
450
502
63.5 x 100 x 140
625
680
76 x 103 x 169
790
STANDARDS
EN 62040-1-1 (safety), EN 62040-2(EMC), EN 62040-3 (VFI-SS-111)
22
96 x 108 x 182
1200
1290
161 x 108 x 195
1675
1775
PYRAMID PLUS SERIES
On-Line Double Conversion Technology
3 Phase in – 3 Phase out from 10 to 300kVA
•
•
•
•
•
•
•
On-line double conversion technology
State of the art IGBT & PWM inverter technology
Parallel ready for future proofing
Reliability of the battery ensured by Info-Charger
Built-in maintenance and static by pass
Built-in output isolation transformer
SNMP solutions for comprehensive communication
with computer & network systems
Communication with building management systems
Extended run time options
12 pulse rectifier options
•
•
•
Specification
MODEL
PPS 310
PPS 315
PPS 320
PPS 330
PPS 340
PPS 360
PPS 380
PPS 3100
PPS 3120
PPS 3160
PPS 3200
PPS 3250
PPS 3300
Output Power (kVA)
10
15
20
30
40
60
80
100
120
160
200
250
300
Output Power (kW)
8
12
16
24
32
48
64
80
96
128
160
200
240
INPUT
Voltage
380V / 400V 3 Phase
Tolerance
±15%
Frequency
50 / 60Hz
Tolerance
±5%
OUTPUT
Power factor
0.8
Voltage
380V / 400V 3Phase
Tolerance (static condition)
± 1%
Tolerance (dynamic condition)
± 5%
Harmonic Distortion rate
on linear load
<3%
Harmonic Distortion rate
on non-linear load
<5%
Crest factor
3
Frequency
50 or 60 Hz
Frequency Tolerance
±0.2%
Overload
10min.
100% - 125% load
125% - 150% load
1min.
Overall Efficiency
≥ 90%
BATTERY
Type
Maintenance-free lead acid batteries
Quantity
30pcs 12V Batteries
32pcs 12V Batt.
DISPLAY
LED Display
Line, Battery, Bypass, Inverter, Maintenance switch, output switch indicators
LCD Display
Load %, Output voltage & frequency, Input and bypass voltages, Battery voltage and current, Temperature, Alarm messages
COMMUNICATION
Interface (Communication Ports)
RS232
Dry Contact Signals
Line Failure, battery low, load on by-pass, emergency stop input
PHYSICAL SPECIFICATIONS
Weight without battery (kg)
Dimensions(mm) WxDxH
225
255
270
490x650x1190
285
400
475
565x860x1400
655
720x820x1450
815
940
1120x820x1650
965
1170
1465
1200x860x1730
1535
1590x950x1900
ENVIRONMENT
Audible Noise
Operating Temperature
Relative Humidity
Protection Level
<55dBA
<60dBA
66dBA
<70dBA
0-40°C
0-95% (non condensing)
IP20
STANDARDS
EN 62040-1-1 (safety), EN 62040-2(EMC)
23
MODULERA
INFORMER SERIES
SERIES
On-Line
Line
Interactive
DoubleTechnology
Conversionwith
Modular
Sinewave
UPS System
Output
1000VA/2000VA/3000VA
3
phase in / 3 phase out 60kVA
(Tower
- 100kVA
& Rack-Models)
200kVA
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
24
Hot Swappable
Pure
sinewave output
Decentralized
for any critical
Parallel
load
Architecture
High(Digital
DSP
BatterySignal
Charging
Processor)
Capacity
Controlled
Extended back up time with additional
Technology
battery pack
Modular
N+X Parallel Redundancy
Boost&and
Plug
Playbuck
Hot Swappable
Automatic Voltage
Power Modules
Regulation
Cold
Start Function
Overload
Parallel
connection
protectionfor up to 4 UPS Frames
Short circuit
Wide
Input Voltage
protection
Window (208Vac to 478Vac)
Compact,
Wide
inputlightweight
frequency and
range
quiet
(40Hz to 70Hz)
Discharge
High
Overall
protection
Efficiency up to 94%
Short recharge
Increased
Output
time
Power Factor (0.9)
Fault alarms
Unity
Input Power
and State
Factor
Warnings
(0.99)
Communication
Low
Input Total Harmonic
Port and Remote
Distortion
Monitoring
(THDi
downSoftware
to 3 %)
Rack
Fit
into
Version
standard
available
19” rack cabinet footprint
Touch-screen LCD display for user-friendly
operation
EPO (Emergency Power Off)
Smart fan speed control
Common battery operation available
for parallel frames
Temperature controlled battery charging option
Programmable battery voltage
(32, 34, 36, 38 or 40 block options available)
Three Level Battery Charge system
with smart charge current adjustment
Powerful charger built in each Power Module
Integral Maintenance Bypass Switch
for easy maintenance
RS232 & 485 communication ports
as standard communication
Megatec ModBus protocol supported
Optional communication interface boards
(SNMP or relay contact board)
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
Specification
MODEL
Frame Capacity
MDL 3300-60K
MDL 3300-100K
MDL 3300-200K
20kVA ( 18kW) to 60kVA (54kW)
20kVA ( 18kW) to 100kVA (90kW)
20kVA ( 18kW) to 200kVA (180kW)
MDL Module Capacity
20kVA/18kW
INPUT
Phase
3 Phase + Neutral + Ground
Rated Voltage
380 / 400 / 415Vac
Voltage Range
208 - 478Vac
Frequency Range
40Hz - 70Hz
Power Factor
≥ 0.99
Current THDi
down to 3%
Generator Compatible
Yes
OUTPUT
Phase
3 Phase + Neutral + Ground
Rate Voltage
380/400/415Vac
Power Factor
0.9
Rated Voltage
380/400/415Vac
Voltage Regulation
Frequency
+/- 1%
Utility Mode
±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional)
Battery Mode
(50/60 ±%0.2)Hz
Crest Factor
3:1
THDv
≤2% with linear load
Waveform
Pure Sinewave
100% - 110%: 60min, 110% - 125%: 10min,125% - 150%: 1min,
AC Mode
Over Load
≥150%: immediately shutdown transfers to bypass
100% - 110%: 60min, 110% - 125%: 10min,125% - 150%: 1min,
Bat. Mode
≥150%: immediately shutdown transfers to bypass
Bypass Mode
Breaker
AC-AC Efficiency
Up to 94%
Eco-Mode Efficiency
97%
BATTERY
Type
Standard: Maintenance-free lead acid batteries. Other types configurable
Quantity (12V VRLA batteries)
Configurable to 32/34/36/38/40 blocks per string
Voltage (12V VRLA batteries)
Charging Current
384/408/432V/456V/480V DC
Frame
18A Max. (charge current set according
to battery capacity installed)
MDL Module
30A Max. (charge current set according
to battery capacity installed)
60A Max. (charge current set according
to battery capacity installed)
6A Max. (charge current set according to battery capacity installed)
DISPLAY
Status LED & LCD
Line Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault
Reading On the LCD
Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Cabinet Temperature
PROTECTION
Short Circuit
Hold Whole System
Overheat
Line Mode: Switch to Bypass
Battery Low
Backup Mode: Shut down UPS immediately
Alarm and Shutdown
Self-diagnostics
Upon Power On and Software Control
EPO (optional)
Shut down UPS immediately
Battery
Advanced Battery Management
Noise Suppression
Complies with EN62040-2
Alarms
Line Failure, Battery Low, Overload, System Fault
COMMUNICATION
Standard
1 x RS232 Communication port, 2 x RS485 Communication ports, 1 x ModBus port, 2 x Communication Slot
Optional
SNMP (Megatec Protocol), Dry Contact Relay Board, EPO
ENVIRONMENT
Operating Temperature
0°C - 40°C
Storage Temperature
-25°C - 55°C
Humidity
0 - %95 non condensing
Altitude
< 1500m
Noise
<60dBA (at 1 meter)
PHYSICAL SPECIFICATIONS
Dimensions WxDxH
Weight Without Batteries (kg)
MDL Module
443 x 131 x 580 - 3U (for all frames)
Frame
600x840x1400
MDL Module
Frame
600x1100x2000
31
150
152
290
STANDARDS
CE, EN/IEC 62040-2, EN/IEC 62040-1-1
25
INFORACK
INFORMER SERIES
19” Rack
Line
Interactive
Cabinet
Technology
& Accessories
with Sinewave Output
1000VA/2000VA/3000VA (Tower & Rack Models)
•
Wide product range from 6U to 47U
Pure sinewave
output
any critical load
•
Lockable
front &
back for
doors
High Battery Charging Capacity
•
Dust-proof
Extended back
updoor
timeand
withside
additional
•
Removable
back
covers for
battery
pack
easy
installation
Boost andcable
buckinlet
Automatic
Voltage
•
Standard
and outlets
(with special
Regulation
brush
protection)
Overload
protection
•
Internal
cabinet
organizer system for cabling
Short circuit
protection
•
Maximum
cabling
efficiency
Compact,
lightweight
and quiet
•
Reliable
and
flexible solutions
Dischargepre-assembled
protection
•
Delivered
or flat packed
Short recharge
•
Adjustable
fronttime
and back 19” mounting rails
Fault alarms and
State
Warnings panel door options
•
Shatterproof
glass
or perforated
Communication
and Remote
•
Active
and silent Port
ventilation
with different
Monitoring
fan
options Software
Rack Version
availableLight Grey or RAL 9005 Black
•
Available
in RAL7035
IP55 Industrial Rack Cabinets
•
Heavy duty with protection against water and dust
and high load capacity
•
Foamed seal on the inside of all doors and panels in
line with IP55 specifications
Accessories
•
Shelves
•
Cable management
•
Cooling units with optional thermostat
•
Other (side rails, drawers, keyboard drawers, monitor holders,
circuit breakers, power strips, power distribution blocks, castor
groups, screws, lightning fixtures, blank panels, grounding kit,
plinths, bay kits, optic patch panel, optic termination box, etc)
26
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
Specification
Wall Mounted Types
U
Construction Structure
Panel Structure
Width (mm)
Depth(mm)
MIDDLE RACK (opening side panels) 600x(450-560)
INF-MIDDLE RACK – 7U
7U
assembled
opening side & rear panels
600
450-560
INF-MIDDLE RACK – 9U
9U
assembled
opening side & rear panels
600
450-560
INF-MIDDLE RACK –12U
12U
assembled
opening side & rear panels
600
450-560
INF-MIDDLE RACK –16U
16U
assembled
opening side & rear panels
600
450-560
INF-MIDDLE RACK – 20U
20U
assembled
opening side & rear panels
600
450-560
MIDDLE RACK (ECO version) (non opening side panels) 600x(450-560)
INF-MIDDLE RACK – 7U
7U
modular - flatpacked / assembled
non-opening side panels
600
450-560
INF-MIDDLE RACK – 9U
9U
modular - flatpacked / assembled
non-opening side panels
600
450-560
INF-MIDDLE RACK –12U
12U
modular - flatpacked / assembled
non-opening side panels
600
450-560
INF-MIDDLE RACK –16U
16U
modular - flatpacked / assembled
non-opening side panels
600
450-560
MIDDLE RACK SWING FRAME (DOUBLE SECTION version)(opening side panels) 600x(450+160)
INF- SWING FRAME - 7U
7U
assembled
opening side panels
600
450+160
INF- SWING FRAME - 9U
9U
assembled
opening side panels
600
450+160
INF- SWING FRAME - 12U
12U
assembled
opening side panels
600
450+160
INF- SWING FRAME - 16U
16U
assembled
opening side panels
600
450+160
SOHO RACK (non opening side panels) 520x(320-400)
INF-SOHO RACK - 6U
6U
modular - flatpacked / assembled
non-opening side panels
520
320
6U - 10"
assembled
non-opening side panels
520
320
INF-SOHO RACK - 10U
10U
assembled
non-opening side panels
520
400
INF-SOHO RACK - 16U
16U
assembled
non-opening side panels
520
400
U
Construction Structure
Feet/Panel Structure
Width (mm)
Depth(mm)
INF-SOHO RACK - 6U- 10"
Stand Alone Types
BIG RACK (ECO version) (non opening side panels) 600x(600-780)
INF- BIG RACK – 22U
22U
modular - flatpacked
w/o PVC Leveling Feet / non opening side panels
600
600-780
INF- BIG RACK – 32U
32U
modular - flatpacked
w/o PVC Leveling Feet / non opening side panels
600
600-780
INF- BIG RACK – 42U
42U
modular - flatpacked
w/o PVC Leveling Feet / non opening side panels
600
600-780
BIG RACK (opening side panels) 600x (647-827)
INF-BIG RACK – 22U
22U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
600
647-827
INF-BIG RACK – 26U
26U
modular - flatpacked/ assembled
with PVC Leveling Feet / opening side & rear panels
600
647-827
INF-BIG RACK – 32U
32U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
600
647-827
INF-BIG RACK – 36U
36U
modular - flatpacked/ assembled
with PVC Leveling Feet / opening side & rear panels
600
647-827
INF-BIG RACK – 42U
42U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
600
647-827
INF-BIG RACK – 47U
47U
modular - flatpacked/ assembled
with PVC Leveling Feet / opening side & rear panels
600
827
BIG RACK (HUGEversion) (opening side panels, with vertical organizer) 800x827
INF-HUGE RACK–32U
32U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
800
827
INF-HUGE RACK–36U
36U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
800
827
INF-HUGE RACK–39U
39U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
800
827
INF-HUGE RACK–42U
42U
modular - flatpacked / assembled
with PVC Leveling Feet / opening side & rear panels
800
827
Width (mm)
Depth(mm)
Server Cabinet Types
U
Construction Structure
Door Structure
Standard
Option
ECO ULTRA RACK (SERVER CABINETS) (non opening side panels) 600x1000
INF-ECO ULTRA RACK - 26U
26U
modular - flatpacked
Perforated
Glass
600
1000
INF-ECO ULTRA RACK - 36U
36U
modular - flatpacked
Perforated
Glass
600
1000
INF-ECO ULTRA RACK - 42U
42U
modular - flatpacked
Perforated
Glass
600
1000
ULTRA RACK(600mm)/SPECIAL RACK(780mm) (SERVER CABINETS) (opening side panels) (600-780) x 1000
INF-ULTRA RACK – 26U
26U
modular - flatpacked / assembled
Glass
Perforated
600/780
1000
INF-ULTRA RACK – 36U
36U
modular - flatpacked / assembled
Glass
Perforated
600/780
1000
INF-ULTRA RACK – 42U
42U
modular - flatpacked / assembled
Glass
Perforated
600/780
1000
INF-ULTRA RACK – 47U
47U
modular - flatpacked / assembled
Glass
Perforated
600/780
1000
Width (mm)
Depth(mm)
INDUSTRIAL COOLING
SYSTEMS
Height (mm)
DESCRIPTION
NOISE LEVEL
Standard
Option
Side Panel Mounted
INF-C-IND-EVE
634
230V/1phase, IP54, 500 W L35L35, 410 W L35L50
Standard (65db)
Low Noise
308
221
INF-C-IND-EVE
634
230V/1phase, IP54, 850 W L35L35, 620 W L35L50
Standard (65db)
Low Noise
308
221
INF-C-IND-EVE
934
230V/1phase, IP54, 1050 W L35L35, 840 W L35L50
Standard (65db)
Low Noise
406
244
INF-C-IND-EVE
934
230V/1phase, IP54, 1400 W L35L35, 1170 W L35L50
Standard (65db)
Low Noise
406
244
INF-C-IND-EVE
934
400V/1phase, IP54, 1400 W L35L35, 1170 W L35L50
Standard (65db)
Low Noise
406
244
INF-C-IND-EVE
1004
400V/3phase, IP54, 2000 W L35L35, 1700 W L35L50
Standard (65db)
Low Noise
406
244
Roof Mounted
INF-C-IND-EVE
180
230V/1phase, IP54, 330 W L35L35, 270 W L35L50
Standard (60db)
Low Noise
476
324
INF-C-IND-EVE
330
230V/1phase, IP54, 600 W L35L35, 510 W L35L50
Standard (65db)
Low Noise
600
320
INF-C-IND-EVE
330
230V/1phase, IP54, 900 W L35L35, 760 W L35L50
Standard (65db)
Low Noise
600
320
INF-C-IND-EVE
350
230V/1phase, IP54, 1400 W L35L35, 1170 W L35L50
Standard (65db)
Low Noise
604
448
INF-C-IND-EVE
350
400V/1phase, IP54, 1400 W L35L35, 1170 W L35L50
Standard (65db)
Low Noise
604
448
INF-C-IND-EVE
358
400V/1phase, IP54, 2000 W L35L35, 1700 W L35L50
Standard (67db)
Low Noise
604
448
INF-C-IND-EVE
508
230V/1phase, IP54, 2700 W L35L35, 2300 W L35L50
70dB
N/A
1234
375
INF-C-IND-EVE
508
230V/1phase, IP54, 4100 W L35L35, 2900 W L35L50
75dB
N/A
1234
375
INF-C-IND-EVE
600
400V/3phase, IP54, 5800 W L35L35, 4500 W L35L50
70dB
N/A
2000
383
INF-C-IND-EVE
800
230V/1phase, IP54, 8000 W L35L35, 5900 W L35L50
76dB
N/A
2000
383
INF-C-IND-EVE
800
230V/1phase, IP54, 10000 W L35L35, 7800 W L35L50
76dB
N/A
2000
383
High Capacity Cooling
27
INFO-STS SERIES (19” Single Phase)
Static Transfer Switch
1 Phase in – 1 Phase out / 50Amp to 100Amp
19” Rack Mountable
•
•
•
•
•
•
•
•
•
•
Synchronons and asynchronons
transfer feature
‘In flight’ transfer mode
Source priority selection
Automatic and Manual transfer in case
of failure on either source
Module replacement without
interruption to load
Fast Diagnostic Response with
microprocessor controller
Internal manual bypass on both sources
Easy Maintenance
High Efficiency
Fast transfer times
Specification
MODEL
STS1050
STS1100
GENERAL SPECIFICATIONS
Nominal Voltage
Nominal Operation Current
220V / 240VAC
50A
Transfer Time
100A
5ms
PHYSICAL SPECIFICATIONS
Cable Entry
Rear
Air Entry/ Exit
Advised Cable Cross Section
Dimensions WxDxH
Weight ( kg )
Bottom/Top
10mm2
35mm2
(19" x 360mm x 2U)
(19" x 360mm x 4U)
9kg
17kg
ENVIRONMENT
Max Altitude
2000m above sea level
Humidity
0-90%
Operating Temperature
0-40°C
Audible Noise (from 1m)
<45dBA
Protection Class
IP20
STANDARDS
Standards
28
EN 62310-2, EN 62310-1, EN 60950-1
INFO-STS SERIES (Three Phase)
Static Transfer Switch
3 Phase in – 3 Phase out / 50Amp to 600Amp
•
•
•
•
•
•
•
•
•
•
•
Increased power quality
Easy monitoring of all parameters via
LCD display
Power blackout protection
Automatic static switching
Electronic and mechanical transfer
between separate input sources
Remote management of power events
Power event logging
Advanced RS232 communication
features
Relay contact alarm interface
Two redundant control power supplies
for internal electronics
Easy front access to all internal
components
•
3 position maintenance
bypass switch
User adjustable parameters
Alarm history (with date
and time)
External emergency
shutdown (EPO) input
High current output
tolerance up to 1000%
Fast response
Input phase balance
and phase sequence
detection circuit
Adjustable input source
frequency
•
•
•
•
•
•
•
Specification
MODEL - 3pole
STS350
MODEL - 4pole
STS3100
STS3150
STS3200
STS3250
STS3300
STS3400
STS3600
STS4100
STS4150
STS4200
STS4250
STS4300
STS4400
STS4600
400A
600A
INPUT
Voltage
380, 400VAC, ( 3 wires for 3pole version and 4 wires for 4pole version)
Voltage Range
310-430VAC
Frequency
50 or 60Hz +/-5%
Voltage Distortion
<10%
Input voltage error window
adjustable
Input frequency error window
adjustable
OUTPUT
Current
50A
100A
150A
Voltage
200A
250A
300A
380, 400VAC, (3 wires for 3pole version and 4 wires for 4pole version)
Crest factor
up to 3.5
Synchronized transfer time
max 1.8 ms
Non-syncronised transfer time
max 10 msec in 0 current mode, 0-25 sec adjustable in delay mode and in 0 current mode
load power factor range
0.6 lagging to 0.9 leading
Efficiency
>98%
Overload
100% to 150% = 1 minute
150% to 200% = 10 seconds
>200% = 0.5 seconds
1000% = 20 msecs
Type of transfer
break before make
As standard
Overcurrent inhibit LCD front panel, Internal maintenance bypass
DISPLAY
LCD Display
2 lines 16 character LCD Display
source 1 voltages, source 2 voltages, output load, phase balance, synchronization
source 1 frequency, source 2 frequency, phase angle degree, temperature
monitored parameters
Indications
8 LEDs arranged as mimic diagram
Control buttons
5 push button interactive with LCD panel
Event log
64 recorded alarm logs from panel or RS232
COMMUNICATION
Interface (Communication Ports)
RS 232 Standard
output inhibit relay, summary alarm relay, static or manual transfer relay, S1/S2 Backfeed trip relay,
Preferred source indicator relay, Load connected to alternate input source relay
Dry contact signals
GENERAL
Neutral connection
available on 4pole version
<5msec : within CBEMA & IEEE for synchronized sources
<11msec : for unsynchronized sources.
transfer time
Manual transfer switch
available
ENVIRONMENT
Operating Temperature
0-40°C
Relative Humidity (non-condensing)
0-90%
PHYSICAL SPECIFICATIONS
Dimensions (mm) WxDxH
Weight ( kg )
685x530x1500
175
685x570x1770
205
215
915x735x1935
220
240
340
STANDARDS
Standards
EN 62310-2, EN 62310-1, EN 60950-1
29
FREQUENCY CONVERTER
3 Phase in – 3 Phase out from 10 to 120kVA
50/60 - 50/60/400Hz
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Double conversion and PWM technology with pure sinewave output
Microprocessor controller
Galvanic Isolation
Up to 91% efficient
Emergency close switch connectionpower off (EPO)
User friendly front panel
Parameters adjustable via the front panel
History log of up to 128 events with date and time indicated
High performance with non-linear loads
Optional dial-up modem connection
Optional remote monitoring via network
SNMP compatibility
Low input harmonic distortion and increased pf with optional 12p version
Low installation and operating cost
Specification
FC 3310
FC 3315
FC 3320
FC 3330
FC 340
FC 3360
FC 3380
FC 33100
FC 33120
Output Power kVA
MODEL
10
15
20
30
40
60
80
100
120
Output Power Kw
8
12
16
24
32
48
64
80
96
600
750
810
Power factor
0.8 lagging
INPUT
Voltage
400 VAC or 380VAC 3 phase,4 Wire + Ground
Tolerance
±10%
Frequency
50 / 60Hz
Tolerance
±5%
Power factor
0.8 ( with optional 12pulse version :0,95)
max RFI
EN 50091-2 Class A
OUTPUT
Voltage
208VAC, 3Phase, 4Wire + Ground
static (balanced load) : +/-2%
Voltage Stability
static (unbalanced load) : +/-4%
Dynamic (0% - 100% step load) : +/-6%
Uptum Time
after 0%-100% step load: max 25msec
Crest factor
3:1
Frequency
50 / 60 / 400 Hz on request
Frequency Tolerance
±0.2%
Overload 101% - 110% load
1h
Overload 130% load
10min.
Overload 150% load
1min.
Overall Efficiency
up to 91%
<3% at linear load
Total Harmonic Distortion
<5% at non-linear load
COMMUNICATION
Interface
RS232 and Dry Contact, SNMP Option
PHYSICAL SPECIFICATIONS
Weight without battery (kg)
Dimensions(mm) WxDxH
240
255
270
285
490x650x1190
490
570
565x820x1400
720x800x1450
1192x874x1720
ENVIRONMENT
Audible Noise
Operating Temperature
Relative Humidity (non condensing)
Max. Altitude
<55dBA
<60dBA
0-40°C
0-95%
<1000m
STANDARDS
Standards
30
EN 50091-1 (safety), EN 50091-2 (EMC),IEC 62040-3 ( class VFI), IP20
63 to 66dBA
AVR SERIES REGULATOR
Automatic Voltage Regulator
Single Phase (2 - 30kVA)
Three Phase (6 - 1000kVA)
•
•
•
Servo motor controlled technology
Fast response time
Reliable stabilization for secure
energy supply
High efficiency
Short circuit protection
Suitable for non-linear loads
Manual Bypass Switch
Wide input voltage range
version (optional)
Output isolation transformer (optional)
Digital display option available
Higher IP applications are available
Phase independent voltage regulation
for three phase models
•
•
•
•
•
•
•
•
•
Specification
MODEL
POWER
SINGLE
PHASE
(kVA)
e-0201
2
e-0351
3.5
e-0501
5
e-0751
7.5
e-1001
10
e-1501
15
e-2001
20
e-3001
30
THREE
PHASE
(kVA)
e-0603
6
e-1053
10.5
e-1503
15
e-2253
22.5
e-3003
30
e-4503
45
e-6003
60
e-7503
75
e-9003
90
Dimensions
WxDxH(cm)
Weight
Response
INPUT
Voltage (V)
L-N
OUTPUT
Maximum
Current
Voltage (V)*
L-N
7.3A
24
80
10.5A
26
80
19A
42
80
27A
50
80
39A
53.5 x 44.5 x 35
58
80
36.5 x 62 x 64
120
80
79A
127
80
106A
74A
138
80
159A
111A
(kg)
V
62
80
3x10.5A
49.5 x 73 x 77.5
WxDxH(cm)
39.5 x 53.5 x 88
39.5 x 58 x 91.5
44.5 x 68.5 x 102.5
54.5 x 103 x 131.5
54.5 x 103 x 131.5
160-245
Voltage (V)
L-L
53A
Maximum
Current
THD
³95
V
50.5 x 39 x 28.5
Frequency
Max
Current
(kg)
25 x 43 x 27
Phase
ENVIRONMENT
Efficiency
(%)
220/230/240±2%
Voltage (V)*
L-L
1Ph + N
Phase
same
as
input
Frequency
w/o
distortion,
no affect
on
harmonics
THD
29A
³96
39A
Efficiency
(%)
Max
Current
³95
3x7.2A
80
3x19A
80
3x27A
206
80
3x39A
20-95%
Temperature
Audible
Noise
Humidity
3x29A
248
80
3x53A
3x39A
270
80
3x79A
3x58A
360
80
3x106A
420
80
3x131A
550
80
624
80
3x191A
0-40°C
<50dBA
20-95%
3x19.4A
3x74A
380/400/415±2%
3Ph + N
same
as
input
w/o
distortion,
no affect
on
harmonics
3x91A
3x110A
e-12003
120
624
80
3x210A
e-15003
150
624
80
3x265A
3x182A
e-22003
220
1200
80
3x387A
3x269A
e-27003
270
1200
80
3x470A
3x327A
e-36003
360
220.5 x 139.5 x 157.3
1600
80
3x633A
3x438A
e-50003
500
184.5x135.5x152
3200
80
3x877A
3x610A
1000
300x150x200
4000
80
3x1758A
3X1223A
e-100003
<45dBA
3x12.7A
³96
110
88.5 x 180.5 x 132.5
0-40°C
58A
e-11003
61.5 x 114.5 x 153
Humidity
19.4A
62
3x158A
Audible
Noise
12.7A
190
277-424
Temperature
3x133A
³97
3x146A
31
SVR SERIES REGULATOR
Single Phase (5 - 30kVA)
Three Phase (15 - 120kVA)
•
•
•
•
•
•
•
•
•
•
Thyristor controlled technology
Microprocessor controller
Wide input voltage range
Stable output voltage
Overload capability of up to 130%
of load
Swift response to voltage fluctuations
High efficiency
Internal Manual Bypass Switch
Operates at high temperature
and humidity
Short circuit and overload protection
Specification
MODEL
SINGLE PHASE
NORMAL RANGE
WIDE RANGE
Power (kVA)
THREE PHASE
svr0501
svr0701
svr1001
svr1501
svr2001
svr3001
svr1003
svr1503
svr2203
svr3003
svr6003
svr9003
svr12003
svr0501w
svr0701w
svr1001w
svr1501w
svr2001w
svr3001w
svr1003w
svr1503w
svr2203w
svr3003w
svr6003w
svr9003w
svr12003w
5
7.5
10
15
20
30
10.5
15
22.5
30
60
90
120
INPUT
Voltage
220 Vac 1 ph
380 Vac 3 ph
Voltage Range (Normal range)*
150-260 Vac
260-450 Vac
Voltage Range(Wide range)*
110-270 Vac
190-467 Vac
50/60 Hz
50 /60Hz
Frequency
Frequency Tolerance
±5%
±5%
Current (max) normal range*
32
47
66
94
125
188
22.0
32
47
66
125
188
250
Current (max) wide range*
46
68
91
136
182
273
32.0
46
68
91
182
273
364
91
136
181
OUTPUT
Voltage
220V AC 1 ph
380V AC 3 ph
Voltage Tolerance
±3% ( ±2% and ±5% optional )
Response Time
320V / sec ( @ ±3% voltage accuracy )
Frequency
50 Hz
Power Factor
1
Crest Factor
3
Current (max per phase)
Overload
23
34
46
68
91
136
100% / 115%
16
23
34
46
10min
115% / 130%
1min
> 130%
Bypass
EFFICIENCY
>95%
DISPLAY/ALARMS
7 segment display
Input Voltage, Output Voltage, Output Current, Frequency, Fault Codes, Temperature
LED Display
Input Out Of Range, Regulator Operation, Bypass Operation, Regulator On, Regulator Off
Alarms
Input Voltage low/high, Output voltage low/high, Output current high, Bypass over current, Frequency out of range
COMMUNICATION
Dry Contacts
Regulator operation and mains present signals
AUDIBLE NOISE
From 1m
<50 dB (A)
ENVIRONMENTAL CONDITIONS
Temperature
Operating
0° to +40°C
Storage
Relative Humidity
.-30° to +75°C
Operating
20% to 90%
Storage
20% to 95%
Protection
IP20
PHYSICAL SPECIFICATIONS
Dimensions(mm) WxDxH
505x500x317
545x500x417
530x660x808
380x500x960
552x610x1115
* The specifications are indicated as per 220VAC Output Voltage Value, these values may vary for 230V or 240V output voltage applications.
32
735 x 895 x 1520
MEDICAL
INFORMER
ISOLATED
SERIES POWER SYSTEMS
Line
Due Interactive
to the electrical
Technology
securitywith
thatSinewave
these systems
Output
1000VA/2000VA/3000VA
(Tower
& Rack
Models)
provide, they are the preferred
choice
in critical
areas;
especially in situations with direct body contact, such
•as operating
Pure sinewave
theatres.output for any critical load
•
High Battery Charging Capacity
•BenefitsExtended
back up
time with additional
of the Isolation
System
battery pack
a power
failure theVoltage
critical medical
•In the event
Boostof
and
buck Automatic
equipment
will continue to operate. This allows
Regulation
personnel
to complete their work. Possible
•medicalOverload
protection
are reduced
to non-critical levels and
•fault currents
Short circuit
protection
currents
that are
present
•any leakage
Compact,
lightweight
and
quiet are reduced
levels toprotection
safe µA levels.
•from mA
Discharge
•
Short recharge time
•
Fault alarms and State Warnings
System Contents:
•Isolation,Communication
PortMonitoring
and Remote
Load and Temperature
Device (ILT-107-V.4)
Monitoring Software
This is a multi-functional
device produced specifically for electrical
Isolation
Systems.
The ILT monitors and displays the
•control inRack
Version
available
system parameters.
1. The insulation resistance of 230V AC systems.
2. Output load currents
3. The temperature of the transformer
4. All input and output voltages.
5. Built in full-graphics display providing an intuitive operation
menu, with operational and fault messages.
Isolation Transformer
This is the main device in an Isolated System. The supplied load is
fully isolated from the building Ground System, therefore any leakage
current is reduced to safe µA levels, required for direct body contact in
medical treatment.
1. Single phase 230V up to 10kVA
2. The short Circuit Voltage to UK standard of <3%
3. No load condition current
4. The initial current value less than 8 x nominal
Optional
The MIPS can be supplied with a built in static switch to connect power
from two separate sources, providing additional power security.
t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk
MPower UPS
33
INFO-PVI
Inform Photovoltaic Inverter
On Grid Version
•
•
•
•
•
•
•
•
•
•
High frequency transformerless design
photovoltaic inverter
Convectional cooling system for quiet
operation
Compact and light weight
Accurate power conversion from solar
panel to local grid
Easy to install
Real Digital Signal Processor
(DSP) controller
Increased efficiency (up to 98%)
Minimum power loss, Maximum
reliability
LCD Display Panel
IP65 Enclosure for both indoor and
outdoor application
Optional Monitoring Software provided
for operational status and electricity
generated data.
•
The INFO-PVI-ON series grid-connected Photovoltaic
Inverter is supplied in a waterproof IP65 enclosure which
can be installed in either a grid connected solar tracker
system or a stationary PV system. Accurate power
conversion from solar panel to local grid allows the
INFO-PVI-ON series to have minimal power loss and
maximum reliability.
Specification
MODEL
INF-PVI-ON2000
INF-PVI-ON3000
INF-PVI-ON5000
INF-PVI-ON10000
Nominal AC Power
2000W
3000W
5000W
10000W
Maximum AC Power Output
2200W
3300W
5300W
10000W
SYSTEM
Main Circuit
Self Current, Voltage System
Conversion Mode
High Frequency PWM
Isolation Method
Transformerless Design
DC INPUT
Rated Voltage
360 VDC
720 VDC
Maximum Voltage
500 VDC
1000 VDC
Operation Voltage Range
120 VDC - 500 VDC
300 VDC -1000 VDC
Max.power point tracking range
150 VDC - 450 VDC
No. of input connections/
max. current for each connection
350 VDC -850 VDC
1 Input
1 Input
2 Inputs
2 Inputs
(14.6A max. for each circuit)
(22A max. for each circuit)
(17.65A max. for each circuit)
(18.6A max. for each circuit)
AC OUPUT
Phase/Wire (AC)
1-phase/2-wire or 1-phase/3-wire (LNG)
3-Phase / 4Wire
230 VAC (184~264.5 VAC)
400 VAC (319~458 VAC)
Rated Voltage
Rated frequency
50-60Hz (47.5~50.2Hz or 59.3~60.5Hz)
Rated Current (AC)
8.7A
13A
21.7A
3x14.5A
Current THD
<5%
<3%
Power factor
>0.99
0.8 ~ 1.0
up to 96%
up to 98%
Efficiency
Protections
Islanding Operation
Detection
Over Voltage, Under Voltage, Over frequency, Under frequency
Passive method
Voltage phase jump detection
Active method
Reactive power control
Communication Interface
RS232, USB, RS485, Dry contact (Optional )
ENVIRONMENT
Temperature
-10°C …… +50°C
Relative Humidity
0-90% RH Maximum, Non-Condensing
Altitude
2000 m
Protection Class
IP65
PHYSICAL SPECIFICATIONS
Dimension (mm)
455x430x170
455x501x170
445x585x247
Net Weight (kg)
23
28
41
STANDARDS
EMC
SAFETY
34
EN61000-6-1, EN61000-6-3, EN61000-3-3
VDE0126-1-1, EN50178, EN60146-1
BATTERY CABINETS
Width
Depth
Height
Weight
-kg
(Without
Batt)
6
655
230
530
15
BC 10
64
42
24
12
12
835
246
700
25
BC 20
76
48
32
15
15
6
6
957
246
760
30
BC 30
144
96
40
38
32
16
16
926
386
1073
50
BC 40
120
72
32
828
386
846
35
BC 50
240
144
64
48
32
32
32
8
1566
386
1166
80
80
64
64
64
45
1774
560
1781
230
400
765
1070
51
400
765
1070
51
525
880
1310
64
835
1160
1310
143
835
1160
1310
143
135
430
390
10
200 AH
6
150 AH
14
120 AH
22
100 AH
40 AH
32
80 AH
25 AH
BC 00
65 AH
Model
18 AH
Cabinet Type
CABINET DIMENSIONS (mm)
12 AH
BATTERY TYPE (VRLA)
7/9 AH
CABINET INFO
TOWER TYPE
BC STANDARD CABINET
BC 60
90
100
V 14
62
31
45
32
V TYPE CABINET
V 15
62
V 24
32
31
V 33
35
V 34
93
78
35
35
INFORMER TOWER CABINET
BC 1000
6
BC 2000
8
135
470
390
10
BC 3000
12
135
470
390
10
MPBC
20
425
563
222 (5U)
16
445
677
132 (3U)
15
483
450
132 (3U)
10
RACK TYPE
BC STANDARD RACK CABINET
20
DSP MULTIPOWER RACK CABINET
MPBC-V
20
INFORMER UPS RACK CABINET
RMBC 1000
6
RMBC 2000
8
483
512
132 (3U)
10
RMBC 3000
12
483
512
132 (3U)
10
35
MPower UPS
t. 01420 82031
e. [email protected]
w. www.mpowerups.co.uk
Mpower UPS Limited
Faraday House, Caker Stream Road, Alton, GU34 2QF, UK