MPower UPS LEADING POWER SOLUTIONS t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk 10 years of uninterruptible power MPower UPS 2 CONTENTS 4 5 6 7 8 9 10 11 12 13 14-15 16 17 18 Company Profile Service Division Sales Division Inform Electronik UPS Product Range Guardian LCD Series Informer Series Sinus Premium LCD Sinus LCD DSP Flexipower Green Triera Series DSP Multipower Convertible DSP Multipower Tower Saver Plus DSP 19 20-21 22 23 24-25 26-27 28 29 30 31 32 33 34 35 Stark Series Pyramid DSP Premium Pyramid DSP T Pyramid Plus Modulera Rack Cabinet Info-STS Single Phase Info-STS Three Phase Frequency Converter Regulators AVR Regulators SVR Medical Isolated Power Systems Info PVI Battery Cabinets t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS 3 COMPANY PROFILE MPower UPS was established in 2005 with the aim of providing a high quality service, which was honest and reliable and which met each customer's diverse needs. Initially established as a UPS maintenance provider, MPower quickly diversified into selling and installing new UPS systems due to customer demand. Founders Michael Brooks and Farid Ahmed had many years of experience in the UPS and Drives industry between them and were able to offer maintenance contracts on a wide range of UPS systems. They were soon joined by an experienced team of engineers giving a strong UK wide coverage for emergency call outs, maintenance and installations. As a result of their experience they were successful in winning a large contract in the nuclear industry. By 2010 MPower had grown out of their Rake offices in West Sussex and had purchased bigger premises with offices and warehousing facilities in Alton, Hampshire. It was also in 2010 that MPower first began entering into discussions with Inform Electronic of Turkey who were looking to enter the UK market at the same time as MPower were actively looking for a new manufacturer of high calibre UPS. 4 Following many meetings and visits to the Inform premises in Istanbul, MPower were so impressed with the quality of the UPS, the attention to detail, the manufacturing facilities and the commitment to continuous research and development that we signed a contract to become Inform's sole UK distributor. The Inform premises in Istanbul are geared to manufacturing and assembling all component parts of the wide range of UPS meaning that they are in complete control of design and quality at each stage of manufacture. Recently, Inform have been acquired by Legrand Group who continue to invest heavily in research and development with the aim of Inform products being at the forefront of the UPS industry. Inform UPS systems, static transfer switches and battery cabinets have now been installed in an ever growing range of sites across the UK. Satisfied customers include headquarters of international banks, London hotels, Data Centres, Government Offices, Police headquarters and the regional offices of a wide range of UK and international companies. SERVICE DIVISION MPower UPS Ltd has the facilities to offer a full service and maintenance package on UPS and related equipment from a whole range of manufacturers. This means we can have trained engineers available for you 24 hours a day, 7 days a week, 365 days a year. We provide a complete solution for all your power protection requirements as one of the UK's leading suppliers and maintainers of emergency and back up UPS power systems, emergency lighting, line conditioners, diesel generators and battery banks. Maintenance Contracts All UPS systems need to be serviced regularly in order to ensure they are operating correctly and that their batteries are in good working order. A maintenance contract ensures, as a minimum, yearly planned UPS maintenance visits by a fully trained engineer, including a battery inspection. Comprehensive contracts can also include all parts and labour and guaranteed response times to site. All contract customers have access to 24 hour emergency call out facility and technical back up. Emergency Should you find yourself in an emergency with a failed UPS, then we can assist even if we have not maintained or installed your UPS. We have UPS and generators available for hire as a short term solution and can have them on site, installed and commissioned within 24 hours. Battery Testing and Maintenance During a service visit we undertake routine maintenance tasks which include checking the open-circuit battery and UPS float voltages, inspecting the physical condition of terminals and connections and logging battery impedance to predict the end of the batteries' useful life. All works are carried out in line with our Environment Policy as part of our commitment to reduce the impact of pollution and the causes of climate change wherever possible. Battery Replacement and Disposal Replacement and disposal of batteries is strictly governed by regulations and must be carried out by licensed disposal companies following prescribed methods. We are experienced in ecologically acceptable removal and disposal of UPS systems and consumable parts, from batteries to complete power systems. Generator Services Standby generators provide vital back up when there is prolonged power failure, however they are often left unused for long periods of time. This means that they require regular service to make sure they are ready for use at the critical time. An alternative and cost effective option is the hire of a generator from MPower UPS which can be on site in a matter of hours We can offer a full installation service for all our generator systems, or alternatively we will be happy to provide your appointed electrical contractor with any assistance that they may require. Emergency Lighting The loss of mains electricity could be the result of a fire or a power cut and the normal lighting supplies fail. This may lead to sudden darkness and a possible danger to the occupants, either through physical danger or panic. MPower can supply and maintain emergency lighting systems from all of the major manufacturers. Please contact us with your exact requirements. Remember, if your battery is old and failing and cannot support your emergency lighting for the required time, it could cost lives. Load Bank Testing We can offer the security of knowing that your critical load is fully protected and that your power protection solution is fully optimised through providing a load bank test. We can provide a mobile load bank to your site and a trained engineer to carry out the tests. Full load bank testing can simulate maximum load and fully tests the whole electrical infrastructure, including switchgear, generators and auto change over systems, identifying any possible risks to your critical load. A written report is provided. Power Factor Correction Power Factor is a measure of how efficiently electricity is being used. We can complete a site survey for you, measure your power factor and suggest ways to improve this. Effective power factor correction can lead to lower energy bills due to increased efficiency in electrical consumption. t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS 5 SALES DIVISION Working with our Customers In order for us to fully understand your power protection needs and therefore be able to offer you the best advice, one of our team of skilled engineers will visit your premises to conduct a free site survey. We will assess your critical power requirements with regard to your present usage and to allow for future growth. We will advise on location, taking into account environmental and practical restraints, and on electrical works which may need to be carried out in preparation for the installation of the new UPS. We will discuss run time with you and advise on external battery requirements, including configuration options. We can advise on and supply all necessary switchgear, monitoring software and generators. We will help you decide on the best technical solution to suit your needs as well as an appropriate service plan to keep your UPS system in sound working order. Optional Extras Switchgear With all our systems we can supply appropriate switchgear from various manufacturers made for your specific requirements. • Battery Isolators for systems from 1kVA to 800kVA • Single UPS Bypass Panels for all systems. These include all Single phase UPS, Three Phase Input to Single Phase output UPS and Three Phase Input Output UPS. • Multiple Bypass Panels are available for all the above to parallel up to 9 UPS modules for high reliability of power, or for high power ratings of up to 6.4MVA. Software With all our systems we can supply appropriate software to monitor the UPS units and control automatic shutdown of servers via serial ports or over local area networks. GSM Remote Monitoring SD3 was originally developed for the security industry; with the addition of an integral battery pack it is ideally suited to UPS applications. It can handle up to eight separate inputs for the UPS or any other site system (e.g. door entry, generators etc.) Text or speech messages may be sent to up to 10 numbers via GSM and/or land line. Features include an internal temperature sensor with an adjustable set point to provide an additional over temperature alarm. After Sales Service Once your order is placed with us our project management team will be in touch to co-ordinate delivery schedules and all required works . They will be the single point of contact for you throughout the installation process and can arrange or liaise with external electrical contractors as required. Our skilled engineers will be on site at a time to suit yourselves to install and commission the UPS and provide a final hand over to you. Your new Inform UPS is covered by a two year warranty giving you peace of mind. Help and support will never be far away and you can rest assured that your critical systems are in safe hands. 6 t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS INFORM ELECTRONIK Inform believes that it is only through continuous investment in research and development that companies, involved in new technologies and developing new products, will grow. Tailor Made Solutions If standard product specifications do not meet customers' needs then Inform designs can be adapted to a tailor-made solution. The Inform product range is backed up by an on-site research and development team, and is constantly being updated to meet both customers' needs and advances in technology. The award winning team of experienced engineers and technicians has been recognised for their achievements in developing the new generation, digital signal processor UPS, and in 2005 they gained the 'Technology Innovation and Creativity Reward' for the three phase IGBT rectifier UPS. Inform Machinery Park Inform has an air-conditioned PCB assembling facility at its plant, created especially for the production of electrostatic sensitive assemblies. Furthermore, in addition to its automatic assembly lines there are manual assembly lines for producing transformers, coils and connectors and other bespoke assemblies. There is the capacity to produce 300 million components per annum. Integrated Production A step apart from other UPS manufacturers, Inform has the ability to produce every part of its products on its own premises, including circuit boards, mechanical parts, cables and transformers. Final assembly and testing is also carried out at the Inform factory complex in Istanbul, Turkey. A Global Brand Inform UPS is a global brand with customers all over the world, extending from Europe to Asia, South America to Africa and Australia. This gives Inform the ability to control the quality of every single part at every step of production. The array of machines across the complex, for producing standard and custom-made products includes computer controlled CNC machines, plastic injection machines, fully automatic painting machines and transformer winding machines. They draw on their long experience of power management to provide a high quality, competitively priced power solution to meet every need. Inform UPS – The Informed Choice. 7 UPS PRODUCT RANGE Line Interactive VA: Guardian LCD Informer Series 600 800 1000 1500 2000 3000 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 1 2 3 5 6 8 10 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 5 6 8 10 On line/Single Phase kVA: Sinus LCD Sinus Premium LCD DSP Flexipower Green Triera DSP Multipower Convertible 15 20 30 40 15 20 30 40 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 140 160 On line/Three phase in Single phase out kVA: 1 2 3 DSP Multipower Convertible ✔ ✔ ✔ DSP Flexipower Green Triera DSP Multipower Tower Saver Plus DSP Pyramid DSP On line/ Three phase in-Three phase Out kVA: Stark Series Pyramid DSP Premium Pyramid DSP T Pyramid Plus 10 15 20 30 40 60 80 100 120k 180 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 20 30 40 60 80 100 120k 140 160 180 ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ 200+ ✔ ✔ ✔ Modular Three Phase in-Three Phase out kVA: Modulera 8 10 15 ✔ t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk 200+ ✔ MPower UPS GUARDIAN LCD SERIES Line Interactive Technology 600VA to 2000VA • • • • • • • • • • • Microprocessor controlled Line Interactive Technology Boost and Buck Automatic Voltage Regulation (AVR) LCD Display Panel Advanced Battery Management (ABM) Input Frequency auto sensing (50/60 Hz) Auto restart after mains recovery Short circuit and overload protection Cold Start Function USB Communication Interface and Remote Monitoring Software Modem/Phone line protection Compact size and user friendly operation Specification MODEL Capacity (VA) GUARDIAN LCD 600AP GUARDIAN LCD 800AP GUARDIAN LCD 1000AP GUARDIAN LCD 1500AP GUARDIAN LCD 2000AP 600 800 1000 1500 2000 INPUT Voltage 220V or 230V Input Voltage Range 162 to 290VAC Frequency 50 or 60 Hz (auto sensing) OUTPUT Power Factor 0.6 Voltage ( On battery ) 220V or 230V ± 10% Waveform ( On battery ) Simulated Sinewave Frequency ( On battery ) 50 or 60 Hz ± 1Hz Voltage Regulation (AVR) AVR automatically increases output voltage 15% above input voltage if -10% to -26% of nominal. AVR automatically decreases output voltage 15% below input voltage if +10% to +22% of nominal. Transfer Time 2 - 6 ms Outlets 1pc Schuko & 1pc IEC C13 2pcs Schuko & 2pcs IEC C13 BATTERY Type Maintenance-free lead acid batteries Recharge Time 6 hours ( to 90% of full capacity) Voltage Quantity 12VDC 24VDC 1x12V 7Ah 1x12V 9Ah 2x12V 7Ah 2x12V 9Ah DISPLAY LCD Display (optional) Input & Output Voltage values, AC mode / Load Level / Battery Capacity Indicators AUDIBLE ALARMS Backup Mode , Low Battery, Overload, Fault PROTECTION Short Circuit, Overload, Battery Discharge, Overcharge, Phoneline COMMUNICATION USB Port Software available as standard ENVIRONMENT Operating Temperature 0-40 °C Humidity 0 to 90% non-condensing Audible Noise at 1m <40dBA Protection class IP20 PHYSICAL SPECIFICATIONS Net Weight (kg) Dimensions (mm) xDxH 4.35 4.7 101 x 298 x 142 7.8 149.3 x 353 x 162 10.1 10.5 158 x 380 x 198 STANDARDS Standards EN 62040-1-1 (Safety), EN 62040-2 (EMC) 9 INFORMER SERIES Line Interactive Technology with Sinewave Output 1000VA/2000VA/3000VA • • • • • • • • • • • Pure sinewave output for any critical load High Battery Charging Capacity Extended back up time with additional battery pack Boost and buck Automatic Voltage Regulation Overload protection Short circuit protection Compact, lightweight and quiet Discharge protection Short recharge time Fault alarms and State Warnings Communication Port and Remote Monitoring Software Specification MODEL Capacity (VA) INF1000 INF2000 INF3000 1000 2000 3000 INPUT Voltage 220V / 230V ± 25% Frequency 50 or 60Hz ± 5% OUTPUT Power Factor 0.6 Voltage (On battery) 220V / 230V ± 5% Wave Form Pure Sinewave Frequency (On battery) 50 or 60 Hz ± 0.5% AVR automatically increases output voltage 15% above input voltage if -9% to 25% of nominal. AVR decreases output voltage 13% below input voltage if +9% to +25% of nominal Voltage Regulation (AVR) Transfer Time 2/4 ms. Overload Automatic shutdown if load exceeds 110% of nominal at 20 sec. and 125% at 2 sec. Outlets 4pcs IEC C13 INTERNAL BATTERY Type Recharge Time (Hours) Maintenance-free lead acid batteries 4 Voltage Quantity Back up Time on full load 5 6 4 5 24 VDC 4 48 VDC 5 48 VDC 2x12V 7Ah 2x12V 9Ah 2x12V 12Ah 4x12V 7Ah 4x12V 9Ah 4x12V 7Ah 4x12V 9Ah 4mins 7mins 10mins 4mins 7mins 3mins 5mins Protection Automatic Self-Test & Discharge Protection, Replace Battery Indicator DISPLAY LED Display Back up, Overload, replace battery indicators ALARMS Line Failure, Battery Low, Overload and Fault PROTECTION Spike Protection (320 joule, 2 ms), Overload Protection, Short Circuit Protection COMMUNICATION Interface (Communication Ports) RS 232 Standard Software Standard ENVIRONMENT Operating Temperature 0-40 °C Humidity 0 to 90% non-condensing Audible Noise at 1m < 40 dBA < 45 dBA Protection Class IP20 PHYSICAL SPECIFICATIONS Tower Type Net Weight (kg) Dimensions (mm) WxDxH 19 20.5 22 28 30 32 135 x 430 x 390 135 x 470 x 390 483 x 450 x 132 483 x 512 x 132 19" Rack Mount Type Dimensions (mm) WxDxH STANDARDS Standards 10 EN 62040-1-1 (Safety), EN 62040-2 (EMC) 34 SINUS PREMIUM LCD SERIES On – Line Double Conversion Technology 1 phase in - 1 phase out 1kVA to 3kVA • • • • • • • • • • • • Online double conversion technology Input power factor correction PFC (>0.99 ) High output power factor ( PF : 0.9 ) Pure sinewave output Wide input voltage and frequency range Smart RS-232 communication port Internal SNMP Slot Card Option Management software compatible Overload & short circuit protection Cold start (DC power on) Smart battery management Compact size, lightweight & low noise Specification MODEL Power(kVA) INPUT Voltage Range Frequency Power Factor OUTPUT Output Power Factor Voltage Voltage Regulation Frequency ( Synchronized range ) Frequency ( Battery Mode ) Harmonic Distortion Crest Factor Output Waveform SPS LCD 210 1 SPS LCD 220 2 SPS LCD 230 3 160VAC ~ 300VAC (@ 0% to 78% Load) 185VAC ~ 260VAC (@ 78% to 89% Load) 210VAC ~ 240VAC (@ 89% to 100% Load) 45Hz ~ 65Hz ≥0.99 (at full linear load) 0.9 220V / 230V / 240VAC <±1% (until low battery warning signal) 3Hz or 1Hz (selectable) 50 / 60Hz ± 0.1% <3% (at full linear load), <6% (@ full non-linear load) 3:1 Sinusoidal 100%-105% : Continuous 106%-120% for 30 seconds Overload Capacity 121%-150% for 10 seconds >150% : Transfer to Bypass Line Mode efficiency ±>86% ±>87% ±>88% Battery Mode efficiency ±>85% ±>86% ±>87% Transfer Time (AC to DC) 0ms Outlets 3pcs IEC C13 & 1pc Schuko 3pcs IEC C13 & 2pcs Schuko 6pcs IEC C13 & 2pcs Schuko BATTERY Type Maintenance-free lead acid batteries Recharge time 5 hours (to 80% of full capacity) Voltage 24VDC 48VDC 72VDC Internal Battery 2pcs 12V 7Ah 4pcs 12V 7Ah 6pcs 12V 9Ah Cold Start Yes DISPLAY LCD Display Input/Output/Bypass Voltage, Input/Output/Bypass Frequency, Load %, Battery Voltage, Internal Temperature ALARMS Battery Mode, Battery Low, Overload, Failure Events PROTECTION Short Circuit Bypass Mode: Fuse, Normal Mode: Output Breaker / Electronic Circuit, Battery Mode: Output Breaker / Electronic Circuit Battery Battery Discharge Management EPO UPS shuts down immediately Over Temperature Normal Mode: Transfers to Bypass Mode, Battery Mode: UPS shuts down immediately COMMUNICATION Interface(Communication Ports) RS-232 Standard, Optional USB Monitoring and Management Software Standard Options Dry Contact Board, USB Board, SNMP Card ENVIRONMENT Temperature 0°C - 40°C Humidity 0% - 90% (without condensation) Noise Level (1m Distance) <50dBA Protection Class IP20 PHYSICAL SPECIFICATIONS Net Weight (kg) 12 22 27 Dimensions(mm) WxDxH 144 x 360 x 220 152 x 438 x 322 190 x 438 x 322 STANDARDS Standards EN 62040-1-1 (Safety), EN 62040-2 (EMC) ACCESSORIES Optional Internal & External SNMP, Dry Contact Board, Additional Charging Board 11 SINUS LCD SERIES On-Line Double Conversion Technology 1 phase in - 1 phase out 1kVA to 3kVA (Tower & Rack Convertible) • • • • • • • • • • On-line double conversion technology Real Digital Signal Processor (DSP) Controller Power factor correction PFC (>0.99) User friendly LCD display Programmable power outlets to allow load shedding Wide input voltage and frequency range Can be configured as 50/60Hz Frequency Converter from LCD Panel Smart communication port and SNMP management capability Hot Swappable Battery Emergency shutdown control through EPO • • • • • • • Overload and short circuit protection Powerful Built-in Charger Extended back up time with additional battery cabinets Cold start (DC power on) Genius battery management (GBM) RS232, USB and SNMP can be activated simultaneously Compact, lightweight and low noise Specification MODEL Power(kVA) INPUT Voltage Frequency Power Factor OUTPUT Power Factor Voltage Voltage Regulation Frequency Frequency Regulation Harmonic Distortion Crest Factor Output Waveform Overload Capacity SS LCD 210 1 SS LCD 220 2 SS LCD 230 3 160VAC - 288VAC 50/60 Hz ±5% (Auto Sensing) >99% 0.8 220 / 230 / 240VAC ±%1 50/60 Hz ± 0,1% <3% 3:1 Sinusoidal 100%-120% for 30 seconds 120%-150% for 10seconds Whole efficiency >85% >88% Transfer Time 0ms Outlets 6pcs IEC C13 4pcs IEC C13 INTERNAL BATTERY Type Maintenance-free lead acid batteries Recharge Time 3 hours (to 90% of full capacity) Voltage 36VDC 72VDC Internal Battery 3pcs 12V 7Ah 6pcs 12V 7Ah 6pcs 12V 9Ah Built in max. Charge Current 1.8A 2.1A 2.7A Back Up Time Full Load 5 min 4 min Half Load 12 min 10 min Cold Start YES DISPLAY LED Display Utility or Bypass, Battery Low, Battery Abnormal, Overload, Site Wiring Fault, Service Mode, UPS Off, UPS Abnormal LCD Display Input /Output Voltage and Frequency Values, Load %, Battery Voltage, Internal Temperature ALARMS Line Failure, Battery Low, Over Load, Failure Events PROTECTION Short Circuit, Over Temperature, Overload, High Voltage, Battery Low, EPO COMMUNICATION Interface RS232 and USB Monitoring and Management Software Standard ENVIRONMENT Temperature 0°C - 40°C Humidity 0% - 90% (without condensation) Noise Level (1m Distance) <50dBA Protection Class IP 20 PHYSICAL SPECIFICATIONS Net Weight (kg) 16 29.5 30 Dimensions(mm) WxHxD 440 x 88 x 405 440 x 88 x 650 440 x 88 x 650 STANDARDS Standards EN 62040-1-1 (Safety), EN 62040-2 (EMC) ACCESSORIES Optional Internal & External SNMP, Dry Contact Board, External Manual Bypass, Rail Kit, External Battery Connection Cable 12 DSP FLEXIPOWER SERIES On-Line Double ConversionTechnology 1 Phase in / 1 Phase out from 3kVA to 10kVA 3 Phase in / 1 Phase out 10kVA • • • • • • • • • • • • • • Real Digital Signal Processor (DSP) Controller Power Factor Correction High output power factor Parallel redundant operation up to 4 units (excluding 3kVA) High performance with the PWM Sinewave topology Cold start function Intelligent Battery Management System extends the life time of batteries Overload, Overheat & Short Circuit Protection Emergency Shutdown Control through EPO User Friendly Multi-Functional LED/LCD Display Panel Energy Saving Mode (ECOMODE) RS232 Communication Port & Management Software Internal SNMP, Relay contact card and RS485 card options Extended Back up time with External Battery Cabinet Specification MODEL Power (kVA) Power (kW) INPUT Phase Configuration Nominal Voltage Minimum Voltage Maximum Voltage Frequency Power Factor OUTPUT Power Factor Phase Configuration Nominal Voltage Wave Form Total Harmonic Distortion at 100% linear load Frequency Frequency Tolerance (free running) Static Voltage Regulation (0%-100% load) Crest Factor Transfer Time Overload FP1103 3 2.4 FP1105 5 4.5 FP1106 6 5.4 FP1108 8 7.2 1Ph + N + PE 220V/230/240V 160 288 ± 5Hz FP1110 10 9 FP3110 10 9 3Ph + N + PE 380V/400V/415V 320V 485V 180 280 45-65 Hz 0.99 0.8 60 min @ (100%-110%) 10 min @ (110%-125%) 0.9 1Ph + N + PE 220V / 230 / 240V (adjustable) Pure Sine Wave <3% 50Hz or 60Hz (adjustable) ±0,2 % <1% 3:1 0sec 2min @ (100%-120%) 30sec @ (120%-150%) Transfers to Bypass @150% ≥92% Total Efficiency ≥90% BATTERY Type Maintenance-free lead acid batteries Recharge Time (for Internal Battery) 4-6h up to 90% Quantity per String 6pcs 12V Batteries 20 pcs 12V Batteries Voltage 72VDC 240VDC Internal Batteries (Optional) 7Ah or 9Ah Cold Start Yes DISPLAY LED + LCD Display Line Mode, Back up Mode, Eco Mode, Bypass Supply, Battery Low, Battery Fault/Disconnected, Overload, UPS Fault, Interruption during transfer LCD Display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load %, Battery Voltage, Internal Temperature Self Diagnostics Power on self test and continuous self diagnostics PROTECTION Overload Protection Transfers to bypass on overload Short Circuit Protection Current limits and internal fuses COMMUNICATION Interface (Communication ports) Standard RS232 port and optional RS485, Internal SNMP, Volt free relay contact card ENVIRONMENT Operating Temperature 0˚C - 40˚C Proposed Temp. to extend battery life 20˚C - 25˚C Humidity up to 90% ( non-condensing ) Audible Noise at 1 m <50 dB <52 dB Protection Class IP20 PHYSICAL SPECIFICATIONS Dimensions(mm) (HxWxD) 449x226x454 585x255x741 Weight - without battery ( kg ) 19 30 38 45 STANDARDS Standards EN62040-1-1 (Safety); EN62040-2 (EMC) ACCESSORIES Optional Internal or External SNMP, Relay Contact Card, Monitoring and Management Software, Internal Battery Holder Apparatus, Additional Charging Set 13 GREEN TRIERA SERIES On-Line Double Conversion 3 Level Inverter Technology 1 Phase in / 1 Phase out 3kVA to 10kVA 3 Phase in / 1 Phase out 10kVA • • • • • • • • • • • • • • • • • • • • • • 14 On-line Double conversion 3 Level Inverter Technology Real Digital Signal Processor (DSP) Controlled IGBT Technology High AC-AC Efficiency (94%) High Output power factor (0.9) Increased Input Power Factor (p.f. > 0.99) Low Input Current THD (<6%) Low Output Voltage THD (<1.5%) Wide input voltage range (90 V - 270 V) Cold Start & Soft Start Features Facility to start up from mains supply without batteries Intelligent battery management system extends the life time of batteries Transformerless design Compact Temperature controlled Smart fan speed Multi-Functional LCD display (ability to adjust or calibrate the UPS without the need for software ) Advanced LCD Panel Menu (ability to monitor 15 different parameters) Event Log displaying up to 500 events Configurable as a 50/60Hz Frequency Converter from the LCD Panel Advanced communication possible through RS232 port Management and monitoring software available for all operating systems SNMP, Modbus, USB Card, Volt Free Relay Contact Card & EPO Card options t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS Specification MODEL GTR1103 GTR1105 GTR1106 GTR1108 GTR1110 GTR3110 Power (kVA) 3 5 6 8 10 10 Power (kW) 2.7 4.5 5.4 7.2 9 9 INPUT Nominal Voltage 220V/230V/240V 380V/400V/415V Minimum Voltage (at half load) 90V 155V Minimum Voltage (at full load) 180V 320 Maximum Voltage 270V 467 Frequency 45-65 Hz Power Factor >0,99 >0,95 Input Current Harmonics <6% <25% OUTPUT Power factor 0.9 Nominal Voltage 208V to 242V adjustable Voltage Tolerance Nominal current @220V ±1% 13.6A 23A 27A 36.4A Wave Form 45.5A 45.5A Pure Sine Wave Total Harmonic Distortion at 100% linear load <1.5% <2% at 100% non-linear load <3.5% <4% Frequency 50Hz or 60Hz (adjustable from LCD Panel) Frequency Tolerance(battery operation) 0.005% Static Voltage Regulation (0%-100% load) 1% Dynamic Voltage Regulation (0%-100% load) 5% Crest Factor 3:1 Overload 100% to 125% overload 10 min 125% to 150% overload 1 min Overall Efficiency (AC-AC) 94% Greenmode ( Ecomode ) Efficiency >98% BATTERY Type Maintenance-free lead acid batteries Recharge Time Quantity per String Voltage 6h - 8h 14pcs 12V Batt 20pcs 12V Batteries 168VDC 240VDC Internal Batteries (Optional) 7Ah, 9Ah or 12Ah Cold Start Yes DISPLAY PANEL Load %, Input/Output/Bypass Voltages, Output Power (W & VA), Output Current Output p.f., Battery +/- Voltage Values, Input/Output Frequency, DC Bus +/- Voltages, Remaining Back Up Time, Internal Temperature, Heatsink Temperature LCD Display Audible and Visual Alarm Warning 41 different Alarm Messages BY-PASS Voltage Tolerance ±10% Frequency Tolerance 3Hz (adjustable from LCD panel between 0.5Hz to 5Hz) Transfer Time 0 ms Overload Capability up to 175% PROTECTION Overload Protection Transfers to bypass on overload Short Circuit Protection Current limits and internal fuses COMMUNICATION Interface (Communication Ports) RS232 (standard), SNMP, Modbus and USB (optional) Relay Contact Port Option Alarm relays programmable from display panel ENVIRONMENT Operating Temperature 0˚C - 40˚C Storage Temperature -15˚C to +55˚C Proposed Temp. to extend battery life 20 - 25˚C Humidity < 95% Maximum Altitude 1000m Audible Noise ( from 1m distance ) <50 dB Protection Class <55 dB IP 20 PHYSICAL SPECIFICATIONS Dimensions (mm) (WxDxH) Net Weight - without battery (kg) 272 x 740 x 758 32 33 34 43.5 44 47 STANDARDS Standards EN 62040-1-1 (safety), EN 62040-2 (EMC), EN 62040-3 (Performance) ACCESSORIES Optional Internal&External SNMP, Relay Contact Board, Monitoring and Management Software, Internal Battery Holder Apparatus, Additional External Charging Set 15 DSP MULTIPOWER CONVERTIBLE SERIES On-Line Double Conversion Technology 1 Phase in / 1 Phase out from 5kVA to 10kVA, 3 Phase in / 1 Phase out from 10 to 20kVA (Tower & Rack Convertible) • • • • • • • • • • • • • On-line double conversion technology Real Digital Signal Processor (DSP) Controller Parallel redundant operation up to 4 units Input Power Factor Correction PFC Transformerless Design High Performance with PWM Sinewave Topology Cold Start Function Overload, Overheat & Short Circuit Protection User Friendly, Multi-Functional LED/LCD Display Panel Energy Saving Mode (ECOMODE) Smart Fan Speed Regulation with temperature control RS232 Communication Port & Management Software Internal SNMP, RELAY contact, RS485 card options Specification MODEL Power (kVA) Power (kW) INPUT Phase Configuration Nominal Voltage Minimum Voltage ( at Half load ) Minimum Voltage ( at Full load ) Maximum Voltage Frequency Power Factor OUTPUT Power Factor Phase Configuration Nominal Voltage Wave Form Total Harmonic Distortion at 100% linear load at 100% non-linear load Frequency Frequency Tolerance (free running) Frequency Synchronized Range Static Voltage Regulation (0%-100% load) Crest Factor Transfer Time DSPMP-1105 5 4.5 DSPMP-1106 6 5.4 DSPMP-1110 10 9 DSPMP-3110 10 9 1Ph + N + PE (Hardwire) 220VAC/230VAC/240VAC 160VAC 180VAC 280VAC DSPMP-3115 15 13.5 DSPMP-3120 20 18 3Ph + N + PE (Hardwire) 380VAC/400VAC /415VAC 277VAC 312VAC 485VAC 45-65 Hz 0.99 Overload Total Efficiency up to 90% Greenmode Efficiency Outlets BATTERY Type Recharge Time 0.95 0.9 1Ph + N + PE (Hardwire) 220VAC / 230VAC / 240VAC Pure Sine Wave <3% <5% 50Hz or 60Hz (adjustable) ±0,1 % ±1Hz or ±3Hz ( selectable ) <1% 3 0sec Up to 10min. @100%~120% Up to 1min. @120%~150% Transfer to bypass @ >150% up to 91% ≥97% Additional external socket boxes available up to 93% Maintenance-free lead acid batteries 4-6h up to 90% 192VDC for 16 pcs 240VDC 240VDC for 20 pcs Quantity per string 20 pcs 12V Batteries Internal batteries 20 pcs 12V 4.5Ah ( internal battery version only ) N/A Built in max. charge current 1.6A 4A Cold Start Yes DISPLAY LED + LCD Display Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Fail/Disconnected, Overload, Transferring with Interruption and UPS Fault LCD display Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage & Internal Temperature. Self Diagnostics Power on self test and continuous self diagnostics Audible and Visual Alarms Line Failure, Battery Low, Transfer to Bypass, System Fault Conditions PROTECTION Overload Protection Transfers to bypass on overload Short Circuit Protection Current limits and internal fuses COMMUNICATION Interface (Communication ports) Standard RS232 port and optional RS485, Internal SNMP, Volt free relay contact Card Monitoring and Management Software Supplied with UPS as standard ENVIRONMENT Operating Temperature 0˚C - 40˚C Proposed Temp. to extend battery life 20˚C - 25˚C Humidity up to 90% ( non-condensing ) Audible Noise at 1 m <50 dB <60 dB Protection Class IP20 PHYSICAL SPECIFICATIONS ( tower position ) Net Weight ( power module) 25kg 26kg 28kg 36kg Net Weight (with internal batteries) 53kg N/A N/A Dimensions(mm) (HxWxD)-power module 440x88x680 440x132x680 440x220x720 Dimensions(mm) (HxWxD)- w/battery vers. 440x176x680 N/A N/A STANDARDS Standards EN62040-1-1 (Safety); EN62040-2 (EMC); EN62040-3 (Performance); EN60950-1 ACCESSORIES Optional Internal&External SNMP, Relay Contact Board, External Manual Bypass, Rail Kit, External Battery Connection Cable, External Socket Box, External Additional Charging Board Voltage 16 DSP MULTIPOWER TOWER SERIES Online Double Conversion Technology 3Phase in / 1Phase out – 15kVA & 20kVA • • • • • • • • • • • • On-Line Double Conversion Technology Real Digital Signal Processor (DSP) Controller Parallel redundant operation up to 4 units High Input Power Factor (0.95) Transformerless Design Cold Start Function Overload, Overheat & Short Circuit Protection User Friendly Multi-Functional LED/LCD Display Panel Energy Saving Mode (GREEN MODE) Intelligent Battery Management System RS232 Communication Port & Management Software SNMP, Relay Contact, RS485 and USB card options Specification MODEL DSPMP-3115T DSPMP-3120T Power (kVA) 15 20 Power (kW) 13.5 18 INPUT Phase Configuration 3Ph + N + PE (Hardwire) Nominal Voltage 380VAC/400VAC /415VAC Minimum Voltage ( at 75% Load ) 277VAC Maximum Voltage 485VAC Frequency 45-65 Hz Power Factor (@linear load ) 0.95 OUTPUT Power Factor 0.9 Phase Configuration 1Ph + N + PE (Hardwire) Nominal Voltage 220VAC/230VAC/240VAC Wave Form Pure Sine Wave Total Harmonic Distortion at 0 to 100% linear load <3% Frequency 50Hz or 60Hz (adjustable) Frequency Tolerance (free running) ±0.2% Frequency Synchronized Range ±1Hz or ±3Hz ( selectable ) Voltage Regulation ±2% Crest Factor 3 Transfer Time 0sec Total Efficiency > 91% Greenmode Efficiency > 95% BATTERY Type Maintenance-free lead acid batteries Voltage 240VDC Quantity per string 20pcs 12V Batteries Built in max. Charge Current 4A DISPLAY LED + LCD Display LCD display Line Mode, Backup Mode, ECO Mode, Bypass Supply, Battery Low, Battery Fail/Disconnected, Overload, Transferring with Interruption and UPS Fault Input Voltage, Input Frequency, Output Voltage, Output Current, Output Frequency, Load Percentage, Battery Voltage & Inner Temperature. Self Diagnostics Power on self test and continuous self diagnostics Audible and Visual Alarms Line Failure, Battery Low, Transfer to Bypass, System Fault COMMUNICATION Interface (Communication ports) Standard RS232 port and optional RS485, Internal SNMP, Volt Free Relay Cards Monitoring and Management Software Supplied as standard ENVIRONMENT Operating Temperature 0 ˚C - 40 ˚C Proposed Temp. to extend battery life 20 - 25 ˚C Humidity up to 90% (non-condensing) Audible Noise at 1 m <60 dB Protection Class IP 20 PHYSICAL SPECIFICATIONS Net Weight Dimensions(mm) (HxWxD) 60kg 62kg 290x650x770 STANDARDS Standards EN62040-1-1 (Safety); EN62040-2 (EMC); EN62040-3 (Performance); EN60950-1 ACCESSORIES Optional Internal&External SNMP, Relay Contact Board, External Manual Bypass, External Battery Connection Cable, External Additional Charging Board 17 SAVER PLUS DSP SERIES On-Line Double Conversion Technology 3 phase in / 1 phase out 15 and 20 kVA • • • • • • • • • • • On-line double conversion technology Real Digital Signal Processor (DSP) controlled, IGBT technology Wide input voltage range (140V-480V) Input Power Factor Correction PFC (>0.97) Intelligent Battery Management System extends the life time of batteries Transformerless Design Compact Manual Bypass LCD display RS 232 and relay interface Management and monitoring software available for all operating systems and SNMP Specification MODEL SD3115 SD3120 Power 15kVA 20kVA INPUT Nominal Voltage 380 V / 400V / 415V 3Phase, N Minimum Voltage 140V 3Phase, N Minimum Voltage (at full load) 260V 3Phase, N Maximum Voltage 480V 3Phase, N Frequency 50 - 60Hz (45 to 65 Hz) Nominal Current 17.4 A / phase 23.3 A / phase Maximum Current 53 A peak / phase 71 A peak / phase Power Factor >0.97 OUTPUT Power Factor 0.7 Nominal Voltage 220V / 230V (adjustable) Wave Form Sinus Total Harmonic Distortion < 3% Frequency 50Hz or 60Hz (adjustable) Voltage Regulation (Static) 1% Crest Factor 3 Overload > 30s (at 150% load) Total Efficiency > 91% BATTERY Type Maintenance-free lead acid batteries Quantity per string 32pcs 12V Batteries Voltage 384VDC Recharge Time for Internal Batteries <4h Discharge Current Wave <10% Internal Batteries (Optional) 12Ah Warning Audible Buzzer through to the end of Battery Discharge DISPLAY LED Panel Line, Bypass, Battery, Inverter, Overload, Fault Indicators LCD Panel Load%, Battery Temperature, Input, Output & Battery Voltages, Output Frequency STATIC BY-PASS Voltage Tolerance 10% (adjustable) Frequency Tolerance 3Hz (adjustable) Transfer Time 0 ms PROTECTION Protections Overload Protection, Short Circuit Protection, High Temperature, Over Voltage, Over Current COMMUNICATION INTERFACE Interface (Communication Ports) RS 232 Dry Contact Signals UPS shutdown, mains failure, low battery, by-pass active, summary alarm ENVIRONMENT Temperature 0 - 40˚C Suggested Temp. to extend battery life 20 - 25˚C Humidity < 95% Audible Noise (from 1m distance) < 55dB Protection Class IP 20 PHYSICAL SPECIFICATIONS Net Weight - without battery (kg) 125 130 Dimensions (mm) (WxDxH) 270x730x780 430x820x970 STANDARDS Standards EN 62040-1-1 (Safety), EN 62040-2 (EMC) ACCESSORIES Optional External SNMP, Monitoring and Management Software, Remote Monitoring Panel, Additional Charging Set, Internal Galvanic Isolation Transformer 18 STARK SERIES On-Line Double Conversion Technology, DSP Controlled IGBT Rectifier UPS 3 phase in / 3 phase out from 10 to 40kVA • • • • • • • • • • • • • • • Real Digital Signal Processor (DSP) controlled transformerless design High Output Power Factor (0.9) High Efficiency (up to 93%) Wide Input Voltage Range Cold Start Capability Increased Efficiency with Eco Mode Operation Parallel Redundant Operation up to 4 Units Common Battery Application with Parallel Systems Static and Manual Bypass Built-in User Friendly LCD/LED Display Panel Remaining back up time indication on the LCD Display panel EPO (Emergency Power Off) Function Short Circuit, Overload, Over temperature, Deep Discharge protection USB, RS232, RS485 & RELAY Contact Communication Ports Compact dimension with internal battery placement options Specification MODEL Power (kVA) Power (kW) INPUT Phase Configuration Nominal Voltage Voltage Range (Full Load) Voltage Range (Half Load) Frequency Power Factor Total Harmonic Distortion (THDi) OUTPUT Power Factor Phase Configuration Nominal Voltage Wave Form Total Harmonic Distortion at 100% load Frequency Frequency Tolerance(free running) Static Voltage Regulation (0%-100% load) Crest Factor Transfer Time Overload ST3310 10 9 ST3315 15 13.5 ST3320 20 18 ST3330 30 27 ST3340 40 36 3Ph + N + PE 380 / 400 / 415 VAC 304~478 323~478 208~478 50/60 Hz ±10% (auto sensing) 0.99 3% 0.9 3Ph + N + PE 380 / 400 / 415 VAC (adjustable) Pure Sine Wave ≤2% with linear load ≤5% with non linear load 50Hz or 60Hz (adjustable) (50/60±0.2%)Hz @ Battery Operation <1% 3:1 0sec 60 min @ (100%-110%) 10 min @ (110%-125%) 1 min @ (125%-150%) Transfers to Bypass @ ≥150% (On-line Mode) Up to 93% Total Efficiency BATTERY Type Maintenance-free lead acid batteries Recharge Time (for Internal Battery) 4-6h up to 90% Quantity per String 16/18/20pcs 32/34/36/38/40pcs Internal Battery Type 7Ah, 9Ah None Internal Battery Quantity Up to 40pcs Up to 60pcs None Standard Charging Current 1,.5A 2.7A 4A 10A Max Charging Current 10A Cold Start Yes DISPLAY Operation Modes Normal Mode, Back up Mode, Eco Mode, Parallel Mode LCD display Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load %, Battery Voltage, Battery Current, Autonomy Time, Temperature PROTECTION Overload, Over Voltage, Overheat, Short Circuit, Low Battery COMMUNICATION Interface (Communication ports) USB, RS485, 3pcs RELAY Contact Signal, Dry Contact ( standard ) UPS Battery Low, AC Power Failure, Shut down UPS ENVIRONMENT Operating Temperature 0˚C - 40˚C Proposed Temp. to extend battery life 20˚C - 25˚C Humidity up to 95% (non-condensing) Max. Altitude without derating up to 1000 meters Audible Noise at 1 m <55 dB <58 dB Protection Class IP20 PHYSICAL SPECIFICATIONS Dimensions(mm) (WxDxH) 250 x 828 x 868 Weight - without battery ( kg ) 65 70 71 93 73 STANDARDS Standards EN62040-1-1 (Safety); EN62040-2 (EMC) ACCESSORIES Optional SNMP & Additional Relay Board 19 PYRAMID INFORMER DSP SERIES PREMIUM SERIES On-Line Line Interactive “Double Technology Conversion” with Technology, Sinewave Output 1000VA/2000VA/3000VA DSP Controlled IGBT Rectifier (Tower UPS& Rack Models) 3phase in / 3phase out 10 to 300kVA • Pure sinewave output for any critical load •• Graphical Touch ScreenCapacity Front Display Panel High Battery Charging •• IGBT Rectifier Extended back up time with additional • Real Digital battery packSignal Processor (DSP) controlled transformerless design Voltage • Boost and buck Automatic • Input Power Factor Correction PFC( >0.99 ) Regulation •• Low Total Harmonic Overload protectionDistortion Level ( THDi ≤ 4% ) •• High Efficiency Short circuit protection •• Wide Inputlightweight Voltage Range Compact, and quiet •• Generator Compatible Discharge protection Operation •• Evolution and redundancy guaranteed by on site Short recharge time Modular Parallel Systems • Fault alarms and State Warnings •• Intelligent batteryPort management system extends Communication and Remote battery life Monitoring Software •• Static and Manual Bypass Rack Version available • EPO (Emergency Power Off) • SNMP option for communicating with computer and LAN • Extended run time options • Low installation and operating costs Accessories Communication • Remote Monitoring Panel &25m Cable For Remote Panel • UPSMAN (Management Software) • Multiserver Shutdown Licence • Internal SNMP kit • External Adapter SNMP Adapter Net Agent Mini DT 522 SNMP Adapter CS121BL Other • • • 20 Separate bypass supply option Parallel Kit Drawer Type Internal Battery Shelves 10 - 30kVA t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS Specification MODEL Output power ( kVA) Nominal Active Power ( kW ) PDSP-P 33010 PDSP-P 33015 PDSP-P 33020 PDSP-P 33030 PDSP-P 33040 PDSP-P 33060 PDSP-P 33080 PDSP-P 33100 PDSP-P 33120 PDSP-P 33160 PDSP-P 33200 PDSP-P 33250 10 15 20 30 40 60 80 100 120 160 200 250 PDSP-P 33300 300 9 13.5 18 27 36 54 72 90 108 144 180 225 270 INPUT Number of phases 3Ph+N+PE Nominal Voltage ( 3ph Phase to Phase ) 380V/400V/415V Voltage range (-15)% (+27)% Voltage range (64% load) (-45)% (+27)% Voltage range (42% load) (-64)% (+27)% Nominal Frequency ( Hz ) 50 or 60 Frequency range for online operation ±10% Input Current THD ≤4% Input Power Factor 0.99 OUTPUT Power factor 0.9 Number of phases 3Ph+N+PE Voltage ( 3ph Phase to Phase ) 380V/400V/415V Static Voltage Regulation at %100 Linear Load ( online&battery mode ) <1% Voltage THD at rated linear load <3% Crest factor 3:1 Frequency (Hz) 50 or 60 Free Running Frequency (Hz) ± 0.01% 125% for 10 minutes Overload 150% for 1 minute Efficiency up to 94% BATTERY Type Maintenance-free Lead Acid Batteries Quantity (pcs ) 62 ( 2*31 ) Battery Protection 60 ( 2*30 ) Deep Discharge Protection with Auto Cut off Battery Test Standard ( Automatic and Manual ) DISPLAY Graphical Flow Diagram for Line, Rectifier, Bypass, Battery, Inverter and Load 3.5" Graphical Touch Screen Input & Output Frequency, Voltage & Current, Load Power Factor, Load%, Load Active & Apparent Power, Bypass Voltage & Frequency, Battery Voltage, Current & Temperature, Autonomy Time (min), STATIC BYPASS Number of phases 3Ph+N+PE Voltage Range for bypass operation ± 10% Frequency Range for bypass operation (Hz) ± 6% ( Configurable ) COMMUNICATION Interface (Communication Ports ) Relay Contact Signals (Adjustable) RS232, RS485 (ModBus) Programmable 4 Relay Contacts to any of following signals ; General Alarm, Input Failure, Battery Failure, Output Failure, Bypass Acvite, Output Overload, High Temperature Others EPO, Generator Interface ENVIRONMENT Storage Temperature Range (°C ) -25 to +55 ( 15 to 40 recomended for longer battery life time ) Operating Temperature Range (°C ) 0 to 40 ( 20 to 25 recomended for longer battery life time ) Relative Humidity Range 0-95% ( non-condensing ) Maximum Altitude without derating (m) 1000 Protection Level IP20 Audible Noise Level from 1m (dBA) 50 52 55 58 60 68 72 77 100 120 160 200 78 78 250 300 PHYSICAL SPECIFICATIONS Output power ( kVA) 10 Dimensions WxDxH (cm) Weight (kg) 15 20 30 40 x 78 x 107 100 114 116 40 52 x 90 x 130 122 180 60 80 67 x 73 x 163 253 285 85 x 78 x 182 405 98 x 87 x 195 522 570 134 x 108 x 195 735 750 800 STANDARDS Standards EN 62040-1-1 (Safety), EN 62040-2 (EMC), EN 62040-3 (VFI-SS-111) 21 PYRAMID DSP-T SERIES On-Line Double Conversion Technology, IGBT Rectifier UPS with Built in Isolation Transformer 3 phase in / 3 phase out from 10 to 300 kVA • • • • • • • • • • • • • Real Digital Signal Processor (DSP) controlled Built in Output Isolation Transformer Input Power Factor Correction PFC (>0.99) Wide Input Voltage Range Generator Compatible Operation Parallel ready for future proofing Intelligent battery management system extends battery life Synchronization Capability from external sources Static and Manual Bypass SNMP option for communication with computer and LAN Extended run time options Low installation and operating costs EPO (Emergency Power Off) Specification MODEL Output Power ( kVA ) Active Power ( kW ) PDSP-T 33010 PDSP-T 33015 PDSP-T 33020 PDSP-T 33030 PDSP-T 33040 PDSP-T 33060 PDSP-T 33080 PDSP-T 33100 PDSP-T 33120 PDSP-T 33160 PDSP-T 33200 PDSP-T 33250 PDSP-T 33300 10 15 20 30 40 60 80 100 120 160 200 250 300 8 12 16 24 32 48 64 80 96 128 160 200 240 INPUT Number of Phases 3Ph + N + PE Nominal Voltage (Ph-Ph) 380V/400V/415V Voltage range (100% load) -15% ~ +27% Voltage range (64% load) -45% ~ +27% Voltage range (42% load) -64% ~ +27% Nominal Frequency (Hz) 50 or 60 ±10% Input Power Factor 0.99 OUTPUT Output Power factor 0.8 Number of Phases 3Ph + N + PE Voltage 380V/400V/415V Static Voltage Regulation at 100% Linear Load ( online&battery mode ) <1% Voltage THD at rated linear load <1.5% Crest factor 3:1 Free Running Frequency (Hz) 50 or 60 ± 0.01% Overload 125% for 10 minutes; 150% for 1 minute Efficiency ≥ 90% (**) STATIC BYPASS Voltage Range 380V / 400V (Ph-Ph) ± 10% Frequency Range for bypass operation (Hz) ±6% (Adjustable) BATTERY Type Maintenance-free lead acid batteries Battery Quantity (pcs) 54 (2 x 27) Battery Protection Deep discharge protection with auto cut off Battery Test Standard (Automatic and Manual) COMMUNICATION Interface (Communication Ports) RS232 & RS422 RELAY Contact Signals AC Failure, Battery Under Voltage, Bypass Operation, Output Failure Others EPO, Generator Interface ENVIRONMENT Storage Temperature Range (°C) -25 to +55 (15 to 40 recommended for longer battery life) Operating Temperature Range (°C) 0 to 40 (20 to 25 recommended for longer battery life) Relative Humidity Range Up to 95% (non-condensing) Maximum Altitude without derating (m) < 1000 Protection Class IP20 PHYSICAL SPECIFICATIONS Dimensions (wxdxh ) cm Weight (kg) 40 x 78 x 107 235 238 52 x 90 x 130 273 450 502 63.5 x 100 x 140 625 680 76 x 103 x 169 790 STANDARDS EN 62040-1-1 (safety), EN 62040-2(EMC), EN 62040-3 (VFI-SS-111) 22 96 x 108 x 182 1200 1290 161 x 108 x 195 1675 1775 PYRAMID PLUS SERIES On-Line Double Conversion Technology 3 Phase in – 3 Phase out from 10 to 300kVA • • • • • • • On-line double conversion technology State of the art IGBT & PWM inverter technology Parallel ready for future proofing Reliability of the battery ensured by Info-Charger Built-in maintenance and static by pass Built-in output isolation transformer SNMP solutions for comprehensive communication with computer & network systems Communication with building management systems Extended run time options 12 pulse rectifier options • • • Specification MODEL PPS 310 PPS 315 PPS 320 PPS 330 PPS 340 PPS 360 PPS 380 PPS 3100 PPS 3120 PPS 3160 PPS 3200 PPS 3250 PPS 3300 Output Power (kVA) 10 15 20 30 40 60 80 100 120 160 200 250 300 Output Power (kW) 8 12 16 24 32 48 64 80 96 128 160 200 240 INPUT Voltage 380V / 400V 3 Phase Tolerance ±15% Frequency 50 / 60Hz Tolerance ±5% OUTPUT Power factor 0.8 Voltage 380V / 400V 3Phase Tolerance (static condition) ± 1% Tolerance (dynamic condition) ± 5% Harmonic Distortion rate on linear load <3% Harmonic Distortion rate on non-linear load <5% Crest factor 3 Frequency 50 or 60 Hz Frequency Tolerance ±0.2% Overload 10min. 100% - 125% load 125% - 150% load 1min. Overall Efficiency ≥ 90% BATTERY Type Maintenance-free lead acid batteries Quantity 30pcs 12V Batteries 32pcs 12V Batt. DISPLAY LED Display Line, Battery, Bypass, Inverter, Maintenance switch, output switch indicators LCD Display Load %, Output voltage & frequency, Input and bypass voltages, Battery voltage and current, Temperature, Alarm messages COMMUNICATION Interface (Communication Ports) RS232 Dry Contact Signals Line Failure, battery low, load on by-pass, emergency stop input PHYSICAL SPECIFICATIONS Weight without battery (kg) Dimensions(mm) WxDxH 225 255 270 490x650x1190 285 400 475 565x860x1400 655 720x820x1450 815 940 1120x820x1650 965 1170 1465 1200x860x1730 1535 1590x950x1900 ENVIRONMENT Audible Noise Operating Temperature Relative Humidity Protection Level <55dBA <60dBA 66dBA <70dBA 0-40°C 0-95% (non condensing) IP20 STANDARDS EN 62040-1-1 (safety), EN 62040-2(EMC) 23 MODULERA INFORMER SERIES SERIES On-Line Line Interactive DoubleTechnology Conversionwith Modular Sinewave UPS System Output 1000VA/2000VA/3000VA 3 phase in / 3 phase out 60kVA (Tower - 100kVA & Rack-Models) 200kVA • • • • • • • • • • • • • • • • • • • • • • • • • • 24 Hot Swappable Pure sinewave output Decentralized for any critical Parallel load Architecture High(Digital DSP BatterySignal Charging Processor) Capacity Controlled Extended back up time with additional Technology battery pack Modular N+X Parallel Redundancy Boost&and Plug Playbuck Hot Swappable Automatic Voltage Power Modules Regulation Cold Start Function Overload Parallel connection protectionfor up to 4 UPS Frames Short circuit Wide Input Voltage protection Window (208Vac to 478Vac) Compact, Wide inputlightweight frequency and range quiet (40Hz to 70Hz) Discharge High Overall protection Efficiency up to 94% Short recharge Increased Output time Power Factor (0.9) Fault alarms Unity Input Power and State Factor Warnings (0.99) Communication Low Input Total Harmonic Port and Remote Distortion Monitoring (THDi downSoftware to 3 %) Rack Fit into Version standard available 19” rack cabinet footprint Touch-screen LCD display for user-friendly operation EPO (Emergency Power Off) Smart fan speed control Common battery operation available for parallel frames Temperature controlled battery charging option Programmable battery voltage (32, 34, 36, 38 or 40 block options available) Three Level Battery Charge system with smart charge current adjustment Powerful charger built in each Power Module Integral Maintenance Bypass Switch for easy maintenance RS232 & 485 communication ports as standard communication Megatec ModBus protocol supported Optional communication interface boards (SNMP or relay contact board) t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS Specification MODEL Frame Capacity MDL 3300-60K MDL 3300-100K MDL 3300-200K 20kVA ( 18kW) to 60kVA (54kW) 20kVA ( 18kW) to 100kVA (90kW) 20kVA ( 18kW) to 200kVA (180kW) MDL Module Capacity 20kVA/18kW INPUT Phase 3 Phase + Neutral + Ground Rated Voltage 380 / 400 / 415Vac Voltage Range 208 - 478Vac Frequency Range 40Hz - 70Hz Power Factor ≥ 0.99 Current THDi down to 3% Generator Compatible Yes OUTPUT Phase 3 Phase + Neutral + Ground Rate Voltage 380/400/415Vac Power Factor 0.9 Rated Voltage 380/400/415Vac Voltage Regulation Frequency +/- 1% Utility Mode ±1%, ±2%, ±4%, ±5%, ±10% of the rated frequency (optional) Battery Mode (50/60 ±%0.2)Hz Crest Factor 3:1 THDv ≤2% with linear load Waveform Pure Sinewave 100% - 110%: 60min, 110% - 125%: 10min,125% - 150%: 1min, AC Mode Over Load ≥150%: immediately shutdown transfers to bypass 100% - 110%: 60min, 110% - 125%: 10min,125% - 150%: 1min, Bat. Mode ≥150%: immediately shutdown transfers to bypass Bypass Mode Breaker AC-AC Efficiency Up to 94% Eco-Mode Efficiency 97% BATTERY Type Standard: Maintenance-free lead acid batteries. Other types configurable Quantity (12V VRLA batteries) Configurable to 32/34/36/38/40 blocks per string Voltage (12V VRLA batteries) Charging Current 384/408/432V/456V/480V DC Frame 18A Max. (charge current set according to battery capacity installed) MDL Module 30A Max. (charge current set according to battery capacity installed) 60A Max. (charge current set according to battery capacity installed) 6A Max. (charge current set according to battery capacity installed) DISPLAY Status LED & LCD Line Mode, Eco Mode, Bypass Mode, Battery Low, Battery Bad, Overload & UPS Fault Reading On the LCD Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load Percentage, Battery Voltage & Cabinet Temperature PROTECTION Short Circuit Hold Whole System Overheat Line Mode: Switch to Bypass Battery Low Backup Mode: Shut down UPS immediately Alarm and Shutdown Self-diagnostics Upon Power On and Software Control EPO (optional) Shut down UPS immediately Battery Advanced Battery Management Noise Suppression Complies with EN62040-2 Alarms Line Failure, Battery Low, Overload, System Fault COMMUNICATION Standard 1 x RS232 Communication port, 2 x RS485 Communication ports, 1 x ModBus port, 2 x Communication Slot Optional SNMP (Megatec Protocol), Dry Contact Relay Board, EPO ENVIRONMENT Operating Temperature 0°C - 40°C Storage Temperature -25°C - 55°C Humidity 0 - %95 non condensing Altitude < 1500m Noise <60dBA (at 1 meter) PHYSICAL SPECIFICATIONS Dimensions WxDxH Weight Without Batteries (kg) MDL Module 443 x 131 x 580 - 3U (for all frames) Frame 600x840x1400 MDL Module Frame 600x1100x2000 31 150 152 290 STANDARDS CE, EN/IEC 62040-2, EN/IEC 62040-1-1 25 INFORACK INFORMER SERIES 19” Rack Line Interactive Cabinet Technology & Accessories with Sinewave Output 1000VA/2000VA/3000VA (Tower & Rack Models) • Wide product range from 6U to 47U Pure sinewave output any critical load • Lockable front & back for doors High Battery Charging Capacity • Dust-proof Extended back updoor timeand withside additional • Removable back covers for battery pack easy installation Boost andcable buckinlet Automatic Voltage • Standard and outlets (with special Regulation brush protection) Overload protection • Internal cabinet organizer system for cabling Short circuit protection • Maximum cabling efficiency Compact, lightweight and quiet • Reliable and flexible solutions Dischargepre-assembled protection • Delivered or flat packed Short recharge • Adjustable fronttime and back 19” mounting rails Fault alarms and State Warnings panel door options • Shatterproof glass or perforated Communication and Remote • Active and silent Port ventilation with different Monitoring fan options Software Rack Version availableLight Grey or RAL 9005 Black • Available in RAL7035 IP55 Industrial Rack Cabinets • Heavy duty with protection against water and dust and high load capacity • Foamed seal on the inside of all doors and panels in line with IP55 specifications Accessories • Shelves • Cable management • Cooling units with optional thermostat • Other (side rails, drawers, keyboard drawers, monitor holders, circuit breakers, power strips, power distribution blocks, castor groups, screws, lightning fixtures, blank panels, grounding kit, plinths, bay kits, optic patch panel, optic termination box, etc) 26 t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS Specification Wall Mounted Types U Construction Structure Panel Structure Width (mm) Depth(mm) MIDDLE RACK (opening side panels) 600x(450-560) INF-MIDDLE RACK – 7U 7U assembled opening side & rear panels 600 450-560 INF-MIDDLE RACK – 9U 9U assembled opening side & rear panels 600 450-560 INF-MIDDLE RACK –12U 12U assembled opening side & rear panels 600 450-560 INF-MIDDLE RACK –16U 16U assembled opening side & rear panels 600 450-560 INF-MIDDLE RACK – 20U 20U assembled opening side & rear panels 600 450-560 MIDDLE RACK (ECO version) (non opening side panels) 600x(450-560) INF-MIDDLE RACK – 7U 7U modular - flatpacked / assembled non-opening side panels 600 450-560 INF-MIDDLE RACK – 9U 9U modular - flatpacked / assembled non-opening side panels 600 450-560 INF-MIDDLE RACK –12U 12U modular - flatpacked / assembled non-opening side panels 600 450-560 INF-MIDDLE RACK –16U 16U modular - flatpacked / assembled non-opening side panels 600 450-560 MIDDLE RACK SWING FRAME (DOUBLE SECTION version)(opening side panels) 600x(450+160) INF- SWING FRAME - 7U 7U assembled opening side panels 600 450+160 INF- SWING FRAME - 9U 9U assembled opening side panels 600 450+160 INF- SWING FRAME - 12U 12U assembled opening side panels 600 450+160 INF- SWING FRAME - 16U 16U assembled opening side panels 600 450+160 SOHO RACK (non opening side panels) 520x(320-400) INF-SOHO RACK - 6U 6U modular - flatpacked / assembled non-opening side panels 520 320 6U - 10" assembled non-opening side panels 520 320 INF-SOHO RACK - 10U 10U assembled non-opening side panels 520 400 INF-SOHO RACK - 16U 16U assembled non-opening side panels 520 400 U Construction Structure Feet/Panel Structure Width (mm) Depth(mm) INF-SOHO RACK - 6U- 10" Stand Alone Types BIG RACK (ECO version) (non opening side panels) 600x(600-780) INF- BIG RACK – 22U 22U modular - flatpacked w/o PVC Leveling Feet / non opening side panels 600 600-780 INF- BIG RACK – 32U 32U modular - flatpacked w/o PVC Leveling Feet / non opening side panels 600 600-780 INF- BIG RACK – 42U 42U modular - flatpacked w/o PVC Leveling Feet / non opening side panels 600 600-780 BIG RACK (opening side panels) 600x (647-827) INF-BIG RACK – 22U 22U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 600 647-827 INF-BIG RACK – 26U 26U modular - flatpacked/ assembled with PVC Leveling Feet / opening side & rear panels 600 647-827 INF-BIG RACK – 32U 32U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 600 647-827 INF-BIG RACK – 36U 36U modular - flatpacked/ assembled with PVC Leveling Feet / opening side & rear panels 600 647-827 INF-BIG RACK – 42U 42U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 600 647-827 INF-BIG RACK – 47U 47U modular - flatpacked/ assembled with PVC Leveling Feet / opening side & rear panels 600 827 BIG RACK (HUGEversion) (opening side panels, with vertical organizer) 800x827 INF-HUGE RACK–32U 32U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 800 827 INF-HUGE RACK–36U 36U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 800 827 INF-HUGE RACK–39U 39U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 800 827 INF-HUGE RACK–42U 42U modular - flatpacked / assembled with PVC Leveling Feet / opening side & rear panels 800 827 Width (mm) Depth(mm) Server Cabinet Types U Construction Structure Door Structure Standard Option ECO ULTRA RACK (SERVER CABINETS) (non opening side panels) 600x1000 INF-ECO ULTRA RACK - 26U 26U modular - flatpacked Perforated Glass 600 1000 INF-ECO ULTRA RACK - 36U 36U modular - flatpacked Perforated Glass 600 1000 INF-ECO ULTRA RACK - 42U 42U modular - flatpacked Perforated Glass 600 1000 ULTRA RACK(600mm)/SPECIAL RACK(780mm) (SERVER CABINETS) (opening side panels) (600-780) x 1000 INF-ULTRA RACK – 26U 26U modular - flatpacked / assembled Glass Perforated 600/780 1000 INF-ULTRA RACK – 36U 36U modular - flatpacked / assembled Glass Perforated 600/780 1000 INF-ULTRA RACK – 42U 42U modular - flatpacked / assembled Glass Perforated 600/780 1000 INF-ULTRA RACK – 47U 47U modular - flatpacked / assembled Glass Perforated 600/780 1000 Width (mm) Depth(mm) INDUSTRIAL COOLING SYSTEMS Height (mm) DESCRIPTION NOISE LEVEL Standard Option Side Panel Mounted INF-C-IND-EVE 634 230V/1phase, IP54, 500 W L35L35, 410 W L35L50 Standard (65db) Low Noise 308 221 INF-C-IND-EVE 634 230V/1phase, IP54, 850 W L35L35, 620 W L35L50 Standard (65db) Low Noise 308 221 INF-C-IND-EVE 934 230V/1phase, IP54, 1050 W L35L35, 840 W L35L50 Standard (65db) Low Noise 406 244 INF-C-IND-EVE 934 230V/1phase, IP54, 1400 W L35L35, 1170 W L35L50 Standard (65db) Low Noise 406 244 INF-C-IND-EVE 934 400V/1phase, IP54, 1400 W L35L35, 1170 W L35L50 Standard (65db) Low Noise 406 244 INF-C-IND-EVE 1004 400V/3phase, IP54, 2000 W L35L35, 1700 W L35L50 Standard (65db) Low Noise 406 244 Roof Mounted INF-C-IND-EVE 180 230V/1phase, IP54, 330 W L35L35, 270 W L35L50 Standard (60db) Low Noise 476 324 INF-C-IND-EVE 330 230V/1phase, IP54, 600 W L35L35, 510 W L35L50 Standard (65db) Low Noise 600 320 INF-C-IND-EVE 330 230V/1phase, IP54, 900 W L35L35, 760 W L35L50 Standard (65db) Low Noise 600 320 INF-C-IND-EVE 350 230V/1phase, IP54, 1400 W L35L35, 1170 W L35L50 Standard (65db) Low Noise 604 448 INF-C-IND-EVE 350 400V/1phase, IP54, 1400 W L35L35, 1170 W L35L50 Standard (65db) Low Noise 604 448 INF-C-IND-EVE 358 400V/1phase, IP54, 2000 W L35L35, 1700 W L35L50 Standard (67db) Low Noise 604 448 INF-C-IND-EVE 508 230V/1phase, IP54, 2700 W L35L35, 2300 W L35L50 70dB N/A 1234 375 INF-C-IND-EVE 508 230V/1phase, IP54, 4100 W L35L35, 2900 W L35L50 75dB N/A 1234 375 INF-C-IND-EVE 600 400V/3phase, IP54, 5800 W L35L35, 4500 W L35L50 70dB N/A 2000 383 INF-C-IND-EVE 800 230V/1phase, IP54, 8000 W L35L35, 5900 W L35L50 76dB N/A 2000 383 INF-C-IND-EVE 800 230V/1phase, IP54, 10000 W L35L35, 7800 W L35L50 76dB N/A 2000 383 High Capacity Cooling 27 INFO-STS SERIES (19” Single Phase) Static Transfer Switch 1 Phase in – 1 Phase out / 50Amp to 100Amp 19” Rack Mountable • • • • • • • • • • Synchronons and asynchronons transfer feature ‘In flight’ transfer mode Source priority selection Automatic and Manual transfer in case of failure on either source Module replacement without interruption to load Fast Diagnostic Response with microprocessor controller Internal manual bypass on both sources Easy Maintenance High Efficiency Fast transfer times Specification MODEL STS1050 STS1100 GENERAL SPECIFICATIONS Nominal Voltage Nominal Operation Current 220V / 240VAC 50A Transfer Time 100A 5ms PHYSICAL SPECIFICATIONS Cable Entry Rear Air Entry/ Exit Advised Cable Cross Section Dimensions WxDxH Weight ( kg ) Bottom/Top 10mm2 35mm2 (19" x 360mm x 2U) (19" x 360mm x 4U) 9kg 17kg ENVIRONMENT Max Altitude 2000m above sea level Humidity 0-90% Operating Temperature 0-40°C Audible Noise (from 1m) <45dBA Protection Class IP20 STANDARDS Standards 28 EN 62310-2, EN 62310-1, EN 60950-1 INFO-STS SERIES (Three Phase) Static Transfer Switch 3 Phase in – 3 Phase out / 50Amp to 600Amp • • • • • • • • • • • Increased power quality Easy monitoring of all parameters via LCD display Power blackout protection Automatic static switching Electronic and mechanical transfer between separate input sources Remote management of power events Power event logging Advanced RS232 communication features Relay contact alarm interface Two redundant control power supplies for internal electronics Easy front access to all internal components • 3 position maintenance bypass switch User adjustable parameters Alarm history (with date and time) External emergency shutdown (EPO) input High current output tolerance up to 1000% Fast response Input phase balance and phase sequence detection circuit Adjustable input source frequency • • • • • • • Specification MODEL - 3pole STS350 MODEL - 4pole STS3100 STS3150 STS3200 STS3250 STS3300 STS3400 STS3600 STS4100 STS4150 STS4200 STS4250 STS4300 STS4400 STS4600 400A 600A INPUT Voltage 380, 400VAC, ( 3 wires for 3pole version and 4 wires for 4pole version) Voltage Range 310-430VAC Frequency 50 or 60Hz +/-5% Voltage Distortion <10% Input voltage error window adjustable Input frequency error window adjustable OUTPUT Current 50A 100A 150A Voltage 200A 250A 300A 380, 400VAC, (3 wires for 3pole version and 4 wires for 4pole version) Crest factor up to 3.5 Synchronized transfer time max 1.8 ms Non-syncronised transfer time max 10 msec in 0 current mode, 0-25 sec adjustable in delay mode and in 0 current mode load power factor range 0.6 lagging to 0.9 leading Efficiency >98% Overload 100% to 150% = 1 minute 150% to 200% = 10 seconds >200% = 0.5 seconds 1000% = 20 msecs Type of transfer break before make As standard Overcurrent inhibit LCD front panel, Internal maintenance bypass DISPLAY LCD Display 2 lines 16 character LCD Display source 1 voltages, source 2 voltages, output load, phase balance, synchronization source 1 frequency, source 2 frequency, phase angle degree, temperature monitored parameters Indications 8 LEDs arranged as mimic diagram Control buttons 5 push button interactive with LCD panel Event log 64 recorded alarm logs from panel or RS232 COMMUNICATION Interface (Communication Ports) RS 232 Standard output inhibit relay, summary alarm relay, static or manual transfer relay, S1/S2 Backfeed trip relay, Preferred source indicator relay, Load connected to alternate input source relay Dry contact signals GENERAL Neutral connection available on 4pole version <5msec : within CBEMA & IEEE for synchronized sources <11msec : for unsynchronized sources. transfer time Manual transfer switch available ENVIRONMENT Operating Temperature 0-40°C Relative Humidity (non-condensing) 0-90% PHYSICAL SPECIFICATIONS Dimensions (mm) WxDxH Weight ( kg ) 685x530x1500 175 685x570x1770 205 215 915x735x1935 220 240 340 STANDARDS Standards EN 62310-2, EN 62310-1, EN 60950-1 29 FREQUENCY CONVERTER 3 Phase in – 3 Phase out from 10 to 120kVA 50/60 - 50/60/400Hz • • • • • • • • • • • • • • Double conversion and PWM technology with pure sinewave output Microprocessor controller Galvanic Isolation Up to 91% efficient Emergency close switch connectionpower off (EPO) User friendly front panel Parameters adjustable via the front panel History log of up to 128 events with date and time indicated High performance with non-linear loads Optional dial-up modem connection Optional remote monitoring via network SNMP compatibility Low input harmonic distortion and increased pf with optional 12p version Low installation and operating cost Specification FC 3310 FC 3315 FC 3320 FC 3330 FC 340 FC 3360 FC 3380 FC 33100 FC 33120 Output Power kVA MODEL 10 15 20 30 40 60 80 100 120 Output Power Kw 8 12 16 24 32 48 64 80 96 600 750 810 Power factor 0.8 lagging INPUT Voltage 400 VAC or 380VAC 3 phase,4 Wire + Ground Tolerance ±10% Frequency 50 / 60Hz Tolerance ±5% Power factor 0.8 ( with optional 12pulse version :0,95) max RFI EN 50091-2 Class A OUTPUT Voltage 208VAC, 3Phase, 4Wire + Ground static (balanced load) : +/-2% Voltage Stability static (unbalanced load) : +/-4% Dynamic (0% - 100% step load) : +/-6% Uptum Time after 0%-100% step load: max 25msec Crest factor 3:1 Frequency 50 / 60 / 400 Hz on request Frequency Tolerance ±0.2% Overload 101% - 110% load 1h Overload 130% load 10min. Overload 150% load 1min. Overall Efficiency up to 91% <3% at linear load Total Harmonic Distortion <5% at non-linear load COMMUNICATION Interface RS232 and Dry Contact, SNMP Option PHYSICAL SPECIFICATIONS Weight without battery (kg) Dimensions(mm) WxDxH 240 255 270 285 490x650x1190 490 570 565x820x1400 720x800x1450 1192x874x1720 ENVIRONMENT Audible Noise Operating Temperature Relative Humidity (non condensing) Max. Altitude <55dBA <60dBA 0-40°C 0-95% <1000m STANDARDS Standards 30 EN 50091-1 (safety), EN 50091-2 (EMC),IEC 62040-3 ( class VFI), IP20 63 to 66dBA AVR SERIES REGULATOR Automatic Voltage Regulator Single Phase (2 - 30kVA) Three Phase (6 - 1000kVA) • • • Servo motor controlled technology Fast response time Reliable stabilization for secure energy supply High efficiency Short circuit protection Suitable for non-linear loads Manual Bypass Switch Wide input voltage range version (optional) Output isolation transformer (optional) Digital display option available Higher IP applications are available Phase independent voltage regulation for three phase models • • • • • • • • • Specification MODEL POWER SINGLE PHASE (kVA) e-0201 2 e-0351 3.5 e-0501 5 e-0751 7.5 e-1001 10 e-1501 15 e-2001 20 e-3001 30 THREE PHASE (kVA) e-0603 6 e-1053 10.5 e-1503 15 e-2253 22.5 e-3003 30 e-4503 45 e-6003 60 e-7503 75 e-9003 90 Dimensions WxDxH(cm) Weight Response INPUT Voltage (V) L-N OUTPUT Maximum Current Voltage (V)* L-N 7.3A 24 80 10.5A 26 80 19A 42 80 27A 50 80 39A 53.5 x 44.5 x 35 58 80 36.5 x 62 x 64 120 80 79A 127 80 106A 74A 138 80 159A 111A (kg) V 62 80 3x10.5A 49.5 x 73 x 77.5 WxDxH(cm) 39.5 x 53.5 x 88 39.5 x 58 x 91.5 44.5 x 68.5 x 102.5 54.5 x 103 x 131.5 54.5 x 103 x 131.5 160-245 Voltage (V) L-L 53A Maximum Current THD ³95 V 50.5 x 39 x 28.5 Frequency Max Current (kg) 25 x 43 x 27 Phase ENVIRONMENT Efficiency (%) 220/230/240±2% Voltage (V)* L-L 1Ph + N Phase same as input Frequency w/o distortion, no affect on harmonics THD 29A ³96 39A Efficiency (%) Max Current ³95 3x7.2A 80 3x19A 80 3x27A 206 80 3x39A 20-95% Temperature Audible Noise Humidity 3x29A 248 80 3x53A 3x39A 270 80 3x79A 3x58A 360 80 3x106A 420 80 3x131A 550 80 624 80 3x191A 0-40°C <50dBA 20-95% 3x19.4A 3x74A 380/400/415±2% 3Ph + N same as input w/o distortion, no affect on harmonics 3x91A 3x110A e-12003 120 624 80 3x210A e-15003 150 624 80 3x265A 3x182A e-22003 220 1200 80 3x387A 3x269A e-27003 270 1200 80 3x470A 3x327A e-36003 360 220.5 x 139.5 x 157.3 1600 80 3x633A 3x438A e-50003 500 184.5x135.5x152 3200 80 3x877A 3x610A 1000 300x150x200 4000 80 3x1758A 3X1223A e-100003 <45dBA 3x12.7A ³96 110 88.5 x 180.5 x 132.5 0-40°C 58A e-11003 61.5 x 114.5 x 153 Humidity 19.4A 62 3x158A Audible Noise 12.7A 190 277-424 Temperature 3x133A ³97 3x146A 31 SVR SERIES REGULATOR Single Phase (5 - 30kVA) Three Phase (15 - 120kVA) • • • • • • • • • • Thyristor controlled technology Microprocessor controller Wide input voltage range Stable output voltage Overload capability of up to 130% of load Swift response to voltage fluctuations High efficiency Internal Manual Bypass Switch Operates at high temperature and humidity Short circuit and overload protection Specification MODEL SINGLE PHASE NORMAL RANGE WIDE RANGE Power (kVA) THREE PHASE svr0501 svr0701 svr1001 svr1501 svr2001 svr3001 svr1003 svr1503 svr2203 svr3003 svr6003 svr9003 svr12003 svr0501w svr0701w svr1001w svr1501w svr2001w svr3001w svr1003w svr1503w svr2203w svr3003w svr6003w svr9003w svr12003w 5 7.5 10 15 20 30 10.5 15 22.5 30 60 90 120 INPUT Voltage 220 Vac 1 ph 380 Vac 3 ph Voltage Range (Normal range)* 150-260 Vac 260-450 Vac Voltage Range(Wide range)* 110-270 Vac 190-467 Vac 50/60 Hz 50 /60Hz Frequency Frequency Tolerance ±5% ±5% Current (max) normal range* 32 47 66 94 125 188 22.0 32 47 66 125 188 250 Current (max) wide range* 46 68 91 136 182 273 32.0 46 68 91 182 273 364 91 136 181 OUTPUT Voltage 220V AC 1 ph 380V AC 3 ph Voltage Tolerance ±3% ( ±2% and ±5% optional ) Response Time 320V / sec ( @ ±3% voltage accuracy ) Frequency 50 Hz Power Factor 1 Crest Factor 3 Current (max per phase) Overload 23 34 46 68 91 136 100% / 115% 16 23 34 46 10min 115% / 130% 1min > 130% Bypass EFFICIENCY >95% DISPLAY/ALARMS 7 segment display Input Voltage, Output Voltage, Output Current, Frequency, Fault Codes, Temperature LED Display Input Out Of Range, Regulator Operation, Bypass Operation, Regulator On, Regulator Off Alarms Input Voltage low/high, Output voltage low/high, Output current high, Bypass over current, Frequency out of range COMMUNICATION Dry Contacts Regulator operation and mains present signals AUDIBLE NOISE From 1m <50 dB (A) ENVIRONMENTAL CONDITIONS Temperature Operating 0° to +40°C Storage Relative Humidity .-30° to +75°C Operating 20% to 90% Storage 20% to 95% Protection IP20 PHYSICAL SPECIFICATIONS Dimensions(mm) WxDxH 505x500x317 545x500x417 530x660x808 380x500x960 552x610x1115 * The specifications are indicated as per 220VAC Output Voltage Value, these values may vary for 230V or 240V output voltage applications. 32 735 x 895 x 1520 MEDICAL INFORMER ISOLATED SERIES POWER SYSTEMS Line Due Interactive to the electrical Technology securitywith thatSinewave these systems Output 1000VA/2000VA/3000VA (Tower & Rack Models) provide, they are the preferred choice in critical areas; especially in situations with direct body contact, such •as operating Pure sinewave theatres.output for any critical load • High Battery Charging Capacity •BenefitsExtended back up time with additional of the Isolation System battery pack a power failure theVoltage critical medical •In the event Boostof and buck Automatic equipment will continue to operate. This allows Regulation personnel to complete their work. Possible •medicalOverload protection are reduced to non-critical levels and •fault currents Short circuit protection currents that are present •any leakage Compact, lightweight and quiet are reduced levels toprotection safe µA levels. •from mA Discharge • Short recharge time • Fault alarms and State Warnings System Contents: •Isolation,Communication PortMonitoring and Remote Load and Temperature Device (ILT-107-V.4) Monitoring Software This is a multi-functional device produced specifically for electrical Isolation Systems. The ILT monitors and displays the •control inRack Version available system parameters. 1. The insulation resistance of 230V AC systems. 2. Output load currents 3. The temperature of the transformer 4. All input and output voltages. 5. Built in full-graphics display providing an intuitive operation menu, with operational and fault messages. Isolation Transformer This is the main device in an Isolated System. The supplied load is fully isolated from the building Ground System, therefore any leakage current is reduced to safe µA levels, required for direct body contact in medical treatment. 1. Single phase 230V up to 10kVA 2. The short Circuit Voltage to UK standard of <3% 3. No load condition current 4. The initial current value less than 8 x nominal Optional The MIPS can be supplied with a built in static switch to connect power from two separate sources, providing additional power security. t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk MPower UPS 33 INFO-PVI Inform Photovoltaic Inverter On Grid Version • • • • • • • • • • High frequency transformerless design photovoltaic inverter Convectional cooling system for quiet operation Compact and light weight Accurate power conversion from solar panel to local grid Easy to install Real Digital Signal Processor (DSP) controller Increased efficiency (up to 98%) Minimum power loss, Maximum reliability LCD Display Panel IP65 Enclosure for both indoor and outdoor application Optional Monitoring Software provided for operational status and electricity generated data. • The INFO-PVI-ON series grid-connected Photovoltaic Inverter is supplied in a waterproof IP65 enclosure which can be installed in either a grid connected solar tracker system or a stationary PV system. Accurate power conversion from solar panel to local grid allows the INFO-PVI-ON series to have minimal power loss and maximum reliability. Specification MODEL INF-PVI-ON2000 INF-PVI-ON3000 INF-PVI-ON5000 INF-PVI-ON10000 Nominal AC Power 2000W 3000W 5000W 10000W Maximum AC Power Output 2200W 3300W 5300W 10000W SYSTEM Main Circuit Self Current, Voltage System Conversion Mode High Frequency PWM Isolation Method Transformerless Design DC INPUT Rated Voltage 360 VDC 720 VDC Maximum Voltage 500 VDC 1000 VDC Operation Voltage Range 120 VDC - 500 VDC 300 VDC -1000 VDC Max.power point tracking range 150 VDC - 450 VDC No. of input connections/ max. current for each connection 350 VDC -850 VDC 1 Input 1 Input 2 Inputs 2 Inputs (14.6A max. for each circuit) (22A max. for each circuit) (17.65A max. for each circuit) (18.6A max. for each circuit) AC OUPUT Phase/Wire (AC) 1-phase/2-wire or 1-phase/3-wire (LNG) 3-Phase / 4Wire 230 VAC (184~264.5 VAC) 400 VAC (319~458 VAC) Rated Voltage Rated frequency 50-60Hz (47.5~50.2Hz or 59.3~60.5Hz) Rated Current (AC) 8.7A 13A 21.7A 3x14.5A Current THD <5% <3% Power factor >0.99 0.8 ~ 1.0 up to 96% up to 98% Efficiency Protections Islanding Operation Detection Over Voltage, Under Voltage, Over frequency, Under frequency Passive method Voltage phase jump detection Active method Reactive power control Communication Interface RS232, USB, RS485, Dry contact (Optional ) ENVIRONMENT Temperature -10°C …… +50°C Relative Humidity 0-90% RH Maximum, Non-Condensing Altitude 2000 m Protection Class IP65 PHYSICAL SPECIFICATIONS Dimension (mm) 455x430x170 455x501x170 445x585x247 Net Weight (kg) 23 28 41 STANDARDS EMC SAFETY 34 EN61000-6-1, EN61000-6-3, EN61000-3-3 VDE0126-1-1, EN50178, EN60146-1 BATTERY CABINETS Width Depth Height Weight -kg (Without Batt) 6 655 230 530 15 BC 10 64 42 24 12 12 835 246 700 25 BC 20 76 48 32 15 15 6 6 957 246 760 30 BC 30 144 96 40 38 32 16 16 926 386 1073 50 BC 40 120 72 32 828 386 846 35 BC 50 240 144 64 48 32 32 32 8 1566 386 1166 80 80 64 64 64 45 1774 560 1781 230 400 765 1070 51 400 765 1070 51 525 880 1310 64 835 1160 1310 143 835 1160 1310 143 135 430 390 10 200 AH 6 150 AH 14 120 AH 22 100 AH 40 AH 32 80 AH 25 AH BC 00 65 AH Model 18 AH Cabinet Type CABINET DIMENSIONS (mm) 12 AH BATTERY TYPE (VRLA) 7/9 AH CABINET INFO TOWER TYPE BC STANDARD CABINET BC 60 90 100 V 14 62 31 45 32 V TYPE CABINET V 15 62 V 24 32 31 V 33 35 V 34 93 78 35 35 INFORMER TOWER CABINET BC 1000 6 BC 2000 8 135 470 390 10 BC 3000 12 135 470 390 10 MPBC 20 425 563 222 (5U) 16 445 677 132 (3U) 15 483 450 132 (3U) 10 RACK TYPE BC STANDARD RACK CABINET 20 DSP MULTIPOWER RACK CABINET MPBC-V 20 INFORMER UPS RACK CABINET RMBC 1000 6 RMBC 2000 8 483 512 132 (3U) 10 RMBC 3000 12 483 512 132 (3U) 10 35 MPower UPS t. 01420 82031 e. [email protected] w. www.mpowerups.co.uk Mpower UPS Limited Faraday House, Caker Stream Road, Alton, GU34 2QF, UK
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement