JPI EDM-900 900/930, EDM-930 900/930 Primary Engine Data Management System Installation Manual
The EDM-900/930 900/930 is a combined electronic indicating system that simultaneously displays powerplant and aircraft systems operating parameters to the pilot, replacing all previous primary digital and/or analog instruments.
PDF
Download
Document
Advertisement
Advertisement
FAA Approved Installation Manual for the EDM-900/930/ Primary Engine Data Management System Report No 908 Page 1 of 37 Rev D Date 3-21-08 TABLE OF CONTENTS 1. Read This First _________________________________________________________________________________ 2 2. Instrument Labeling______________________________________________________________________________ 3 3. Operation______________________________________________________________________________________ 4 4. Locating and Installing the Indicator and Remote Alarm Display __________________________________________ 6 5. EDM-900 & EDM-930 Key Card Installation__________________________________________________________ 7 6. Routing the Wiring Harnesses ______________________________________________________________________ 8 7. Power Connection _______________________________________________________________________________ 8 8. Probe Wiring ___________________________________________________________________________________ 9 9. Wiring Markings ________________________________________________________________________________ 9 10. Exhaust Gas Temperature Probe (EGT) Installation ____________________________________________________ 9 11. Turbine Inlet Temperature (TIT) Probe Installation (optional) ___________________________________________ 10 12. Cylinder Head Temperature (CHT) Probe Installation__________________________________________________ 11 13. Outside Air Temperature (OAT) Probe Installation ____________________________________________________ 11 14. Induction Air (IAT), Compressor Discharge Temperature Probe Installation (optional)________________________ 11 15. Carburetor Probe Installation (optional) ____________________________________________________________ 12 16. Oil Temperature Probe Installation_______________________________________________________________ 12 17. Oil Pressure Sensor Installation _________________________________________________________________ 12 18. Fuel Pressure Sensor Installation __________________________________________________________________ 13 19. Ammeter Shunt Installation _______________________________________________________________________ 14 20. General Fuel Flow Transducer Installation __________________________________________________________ 15 21. Fuel Level Sender Wiring Types ___________________________________________________________________ 15 22. GPS Interface _________________________________________________________________________________ 18 23. Manifold Pressure (MAP) Sensor __________________________________________________________________ 19 24. RPM Sensor installation _________________________________________________________________________ 21 25. EDM-900/930 Specifications and Limitations_________________________________________________________ 22 26. Component Parts _______________________________________________________________________________ 23 27. Weight and Balance Data ________________________________________________________________________ 24 28. Pilot Programmable Mode _______________________________________________________________________ 25 29. Trouble Shooting _______________________________________________________________________________ 28 30. Connector Pin Assignments for 4,6,7,8,9 cylinders_____________________________________________________ 29 Edm-900/930_______________________________________________________________________________________ 34 31. Instructions for Continued Airworthiness (ICA) _________________________________ Error! Bookmark not defined. 23. Certificate of Compliance, Fuel Level Transmitters _________________________________________________ 37 24. Instructions for Continued Airworthiness (ICA) ____________________________________________________ 37 32. Fuel Flow installation Report 503___________________________________________________________ Appendix-A The Owner of the EDM-900/930 must keep this manual J.P. INSTRUMENTS PO BOX 7033 HUNTINGTON BEACH CA Last printed 3/10/2009 11:28:00 AM FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 2 of 37 Rev D Date 3-21-08 1. Read This First • The following notes apply to a new installation. Read this section before proceeding. • The JPI warranty found in the back of the pilots guide clearly states that JPI will replace defective parts under warranty, but does NOT cover labor to remove or install any parts. • The most common cause of probe problems is poor terminal crimps. Crimp ring terminals with AMP tool or equivalent. Fold back the wire double before crimping terminals. 2 1/4" yellow Thermocouple wire harness • red 1/4" 1 1/2" Fold back wire double before crimping terminals • This installation will require some parts unique to your aircraft that are not supplied with the kit, (including but not limited to tie-wraps, hoses and fittings). Acquire all the necessary parts prior to beginning the installation. • Do not use aluminum fittings or Teflon tape or pipe sealant with the FXT-201 or FXT-231 fuel flow transducer. • Write down the K-factor engraved on the side of the fuel flow transducer here _______. Once the transducer is installed and covered with the fire sleeve, you will not be able to access this K factor. • Determine the locations of all holes before drilling to ensure that nothing interferes with the probe, clamp, clamp screw or wire. • Provide service loops at the instrument so that it can be moved for maintenance or troubleshooting. • Thermocouple wire length is not critical. Trim to required length, allowing for service loops at the engine so that probes can be swapped with probes on adjacent cylinders for troubleshooting purposes. • Dress all wires away from high temperature components such as exhaust stacks. • Never splice thermocouple wire using copper wire. Use only K-type thermocouple wire. Solder using zinc chloride flux such as Nokorode brand – rosin flux alone won’t work. • Observe correct polarity on all probe wires. Connect like colors together (red to red, yellow to yellow). • The instrument must be grounded at the engine, not at the avionics ground. • Record the installation of the EDM-900 or EDM-930 on a FAA form 337. Make an entry in the aircraft logbook. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System 2. Report No 908 Page 3 of 37 Rev D Date 3-21-08 Instrument Labeling The TSO label on the instrument is marked as to the instrument configuration. The part number of the instrument is as follows: Model designation system by part number for EDM-900/930 Model Number / Part Number Description EDM-900 PN 790000-A- [XXX] Plasma Type Display EDM-930 PN 790000-C- [XXX] TFT (liquid crystal) Type Display PRIMARY INSTRUMENTS EGT 4-6 CHT 4-6 OIL TEMP OIL PRESS FUEL FLOW FUEL PRESS RPM MAP NON-PRIMARY INSTRUMENTS Remote Display TIT OAT, AMP, VOLTS, CARB, IAT Shock Cooling Lean Find Differential EGT CDT FUEL Quantity Percent of HP Example PN 790000-A-(XXX) 120 012 011 010 009 008 007 006 005 004 003 002 001 NA - Display only X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 4 6 7 8 9 EGT CHT RPM MAP O-P O-T OAT FF V/A RAD FLEV F-P TIT CDT IAT/CRB (XXX) Cylinder OPTION CYLINDER & OPTIONS CONFIGURATION 2.1 Primary TSO Label [ [ [ [ ] ] ] ] E D M -9 30 E D M -900 E D M -930 E D M -950 PN PN PN PN 790000-C -[120] W T-2.7 L B S . 79 0000-A -[X X X ] W T-1.7 L B S . 79 0000-C -[X X X ] W T-2.7 L B S . 79 0000-B -[X X X ] W T-1.7 L B S . S erial N o. XXXX D O -160D E N V .C A T . D 1X B A B [S B M ]XX X X XX A B B B A W M [A 3C 3]X XA D O -178B Level -C , H /W 7 999-X R ev A S /W P N 7990-X M FG P O W E R IN P U T: 14 / 28 VD C C U R R E N T: 4 A m p s m ax N ote: E D M -900 /930 /950 T S O -C 55 , inc om plete s ys tem fo r T y pe I (F loat In st.), no F loat s enso r tested . N ote: E D M -950 (D ispla y-les s) in com plete sys tem fo r all T S O 's N ote: P N 790 000-C -120 incom ple te sy stem D ispla y only. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 4 of 37 Rev D Date 3-21-08 3. Operation The EDM-900/930 is a combined electronic indicating system which simultaneously displays to the pilot powerplant and aircraft systems operating parameters. It includes the following indicating systems; replacing all previous primary digital and/or analog instruments: 1. Engine revolutions per minute 2. Engine Manifold Pressure (MAP) 3. Engine Cylinder Head Temperature 4. Engine Exhaust Gas Temperature 5. Engine Oil Temperature 6. Engine Oil Pressure 7. Fuel Pressure 8. Fuel Flow 9. Fuel Quantity (Left Wing and Right Wing tanks) 10. Alternator/Generator Output - Volts and Amps. 11. Outside Air Temperature 12. Turbocharger, Compressor Discharge Temperature (Primary on some turbocharged engines). 13. Turbine Inlet Temperature 14. Induction Air Temperature or Carburetor inlet temperature Refer to Pilots Guide Rev D or higher or AFM for detailed operating instructions. 3.1 Remote Alarm Display (RAD) The RAD is a 0.2” high, 8 character independent display. The RAD will still function if the main display is inoperable. An alarm—such as the CHT is 480° on cylinder number 2—is displayed as 480CHT2. The label CHT2 will flash whenever an over-temperature exists and will extinguish when the temperature falls below the limit temperature. Other alarms would be displayed as, for example: 2780 RPM. The RAD is located directly in front of the pilot and displays digital caution and limit excedances when any of the parameters has reached its preset trigger point. Whenever limit alarms are not triggered, the RAD continuously displays MAP and RPM. On initial startup or whenever power is turned on, the words “EDM900 (or EDM-930) PRIMARY” is displayed, followed by the make and model of the aircraft for which the primary limits are set Reference: Pilots Guide Rev D or later. Alarm hierarchy When a measurement limit is reached, the pilot should momentarily depress the STEP button on the EDM-900/930 instrument to extinguish the particular flashing alarm acronyms. If another measurement has also reached its limit, that label will then begin to flash. The pilot should continue to monitor the affected parameters as he would if a conventional analog display had reached a limit. The bar graph functions of CHT, EGT, and TIT remain displayed for easy reference should one of these limits be reached. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 5 of 37 Rev D Date 3-21-08 Dimming Automatic dimming is provided to dim both the panel display and the remote alarm display. Dimming can also be accomplished manually to change the Automatic setting. Tapping the far right button below the display decreases brightness. Continuously holding this button increases brightness. Remote Display EDM-900 Display EDM-930 Display FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 6 of 37 Rev D Date 3-21-08 4. Locating and Installing the Indicator and Remote Alarm Display 4.1 Single Engine Aircraft EDM-900/930 A) The EDM-900/930 display should be located as close as possible to the pilot with an unobstructed view and for easy access to the buttons on the instrument. A remote display is also provided for alarm indications directly in front of the pilot. Installation should be done in accordance with advisory circular AC43.13-1A. The diagram below should be used as a guide for cutting and drilling the mounting and buttonholes in the instrument panel. The dimensions shown are for the final cutouts. Allow extra clearance for any panel finish such as powder coat. The plastic button caps are removable by grasping and pulling each off. The EDM-900 mounts in a custom 5+ inch cutout and the 930 mounts in a 6x4.5 cutout. Mount the indicator using the figure below as a guide. B) The Remote Alarm Display PN-790749 mounts in a ½ inch hole in the panel directly in front of the pilot.. 4.2 Edm-900 Panel Cutout FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 7 of 37 Rev D Date 3-21-08 5. EDM-900 & EDM-930 Key Card Installation The EDM Key Card activates the primary engine instrument abilities of you engine monitor. This card contains the primary engine instrument data. After installation do not remove the Key Card from the instrument. The key card is programmed with the serial number of your EDM and the make, model and year of your aircraft. Every time you power up the EDM, the Remote Auxiliary Display (RAD) will show your aircraft make and model. Installation With the EDM removed from the aircraft, position it on a flat surface with the rear of the instrument facing you as shown below. You do not have to remove any cables if you have sufficient service loop available. The location of the Key Card access door is different between the EDM-900 and EDM-930. Follow the appropriate instructions below. EDM-900 Open the small access door on the side of the EDM-900 using the appropriate tool. EDM-930 Open the small access door on the top of the EDM-930 using the appropriate tool. UP KEY CARD Hold the Key Card so that the UP arrow is facing up and in insertion arrow is facing to the right. Hold the Key Card so that the UP arrow is facing to the right and in insertion arrow is facing to down. Insert the Key Card in the guide rails until you feel it snap into place. Secure the access door. Power up the EDM and confirm that your aircraft make and model is initially shown in the RAD upon power up. Install the EDM back into the aircraft. Your installation of the Key Card is complete. If your EDM should ever have to be replaced with a unit with a different serial number, the factory will reprogram your Key Card to match the new serial number. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 8 of 37 Rev D Date 3-21-08 6. Routing the Wiring Harnesses Five connectors are protruding from the rear of the instrument. Connect the five wiring harnesses to the rear of the instrument and run the cables through the firewall into the engine compartment. Allow sufficient service loop to facilitate removal of the connectors for servicing. These wiring harnesses are labeled as follows: Conn J1 J2 J3 J4 J5 J6 Harness PN 790200 700700 700702 790420 700709 790719-1 790719-2 790719-3 790719-4 790719-5 790719-6 790719-7 790719-8 790745 Oil temperature, Induction temperature, Carburetor temperature, Outside air temperature, Turbine inlet temperature, Turbine inlet temperature 2, Power, Engine ground, MFD input, MFD output CHT, EGT 6 cylinder CHT, EGT 4 cylinder RPM, MAP, Oil pressure Serial data to GPS, Serial data from GPS, Fuel flow transducer no fuel level Fuel pressure Carb, amperes, no fuel level Fuel pressure Carb , amperes, capacitive fuel level Fuel pressure Carb, amperes, resistive fuel level option No Fuel Level, Fuel Pressure Injected, psi, Amps Fuel pressure Injected psi, amperes, capacitive fuel level Fuel pressure Injected psi, amperes, resistive fuel level. Fuel pressure Injected psi, amperes, Voltage fuel level. Fuel pressure Carb, amperes, voltage fuel level. Category 5 jack and cable for External remote display Route the wires from the connectors through the firewall using fireproof rubber grommets and flame retarding silicone. Use an existing hole if possible. All wires must be routed away from high temperature areas (exhaust stacks, turbochargers, etc.). Secure probe and sensor leads to a convenient location on the engine approximately 8 to 12 inches from the probe or sensor, being sure there is sufficient slack to absorb engine torque. It is essential in routing the probe wire that this wire not be allowed to touch metal parts of the air-frame or engine since abrasion will destroy this high temperature wire. Secure wires along the route to the indicator. Secure wire using original clamps, tape or tie wrap if possible. CAUTION: Be sure any wiring does not obstruct the control movement under the instrument panel. The probe wires must not be tied in with ignition, alternator or engine cabin heater ignition wires because of potential interference with temperature readings. The temperature probe wiring harness is made of Chromel-Alumel alloy wires that must not be substituted or extended with copper wire. The power and ground wire are normal copper. Temperature probe leads may be spliced with additional Chromel-Alumel wire using copper butt splices. When the installation is complete all wires should be secured using ties and carefully checked for interference, rubbing or chafing with flight control cables or other moving parts. 7. Power Connection The EDM-900/930automatically accommodates both 14 and 28-volt electrical systems. The instrument may reset on engine start for 14vdc systems, this is normal. Instrument resets at 10 vdc. Using the J1 connector harness 790200, connect the power lead (red) to a separate 5-amp circuit breaker for each instrument connected to the master power bus. Connect the ground wire to the engine block. The EDM-900 has a 10-second warm-up. No connection to the aircraft dimmer system is required because the instrument dims automatically with reductions in ambient light. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 9 of 37 Rev D Date 3-21-08 8. Probe Wiring When cutting the pair of leads to the proper length to connect to the probes, leave enough slack in the wiring so that probe may be interchanged to an adjacent cylinder if necessary for trouble-shooting and servicing. Thermocouple wire length is not critical and should be trimmed to any length as required for a clean installation. The Temperature probe must be wired with the correct polarity. The temperature probe connects to its temperature indicator with yellow jacket Teflon Chromel Alumel wire supplied. Strip the wires as shown below—observing colorcoding. 2 1/4" yellow Thermocouple wire harness red 1/4" Fold back wire double before crimping terminals 1 1/2" Terminate each wire with a crimp-on ring terminal, provided. The ring terminals may be crimped with a “service-type” tool, however AMP part number 48518 crimp tool is recommended. Verify the quality of each crimp with a sharp tug on the wire. The terminal should be impossible to pull off when crimped correctly. ring terminal shrink tubing Place a ¼ x 4-inch sleeve over each pair of wires in the wiring. Connect the wire ring lug to the probe ring lug using the supplied number 4 screws and nuts, placing the star washer between the ring lugs, not against the nut. Important: place star waster between two ring terminals and tighten nut and bolt as necessary to instrument to probe Slide the sleeve over the joint and secure with three tie-wraps. 1/4 x 4" sleeve tie-wrap 3 places The most common installation problems are related to poor quality terminations. 9. Wiring Markings The EDM-900/930is supplied with special Teflon insulated Chromel Alumel factory assembled wiring harness configured for the correct number of cylinders. The wire harness is marked E1= EGT-1, C1= CHT-1, etc. NOTE: Unlike most other EGT & CHT installations the probe wire length is not critical and should be trimmed to any length as required for a clean installation. Do not extend the thermocouple wire with copper wire. 10. Exhaust Gas Temperature Probe (EGT) Installation Use the J2 connector harness 700700 or 700702 labeled E1 through E4 or E6. Remove the existing EGT gage and Probe. Replace with JPI probe M-111 in all exhaust stacks. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System EGT probe Drill no. 40 pilot hole, then no. 30 hole. exhaust stack CHT probe 2" to 4" Report No 908 Page 10 of 37 Rev D Date 3-21-08 The Model M-111 Probe will fit any engines where the existing holes in the exhaust stack are 1/8" to 1/4" in diameter. If no hole exists, it will require the drilling of a 1/8" diameter hole and ream to fit. It is important that each probe be mounted the same distance from its exhaust stack flange. A nominal distance of 2 to 4 inches from the exhaust flange is recommended. If the recommended distance is impractical because of obstructions, slip joints or bends in the exhaust system then position the probes a uniform distance from the flange as space permits. Do not mount probes in slip joints. Be certain to locate all holes BEFORE drilling to ensure that nothing interferes with the probe, clamp, screw or wire. Careful matching of probe position will provide best temperature readings. Insert the probe in the exhaust or previously drilled hole so that the tip of the probe is in the center of the exhaust stream. Tighten the stainless steel clamp to a torque of 45 in/Lbs. Cut off the excess strap close to the screw. Clamp Seal Washer Thimble note orientation of slot Probe Position probe in approximate center of exhaust RADIAL ENGINES Radial engine exhaust, require a larger EGT clamp (supplied) to fit the 2.5 inch exhaust pipe. The EGT probe is installed in the same fashion as a Lycoming or Continental engine and should be placed between the exhaust pipe flange and the accumulator at a distance of 2 to 3 inches form the engine exhaust flange. Cylinder head temperatures are measured with a spark plug gasket type probe placed under the front sparkplugs . Refer to the engine manufactures red line and set the EDM-700 appropriately. Front spark plugs will read 15 to 20 degrees cooler than the rear plugs. Do not route the EGT/CHT harness in with the ignition harness. Do not extend the yellow thermocouple leads with copper wire. 11. Turbine Inlet Temperature (TIT) Probe Installation (optional) Use the J1 connector harness 700200 and insert the yellow wire into the connector pin 16 and the red wire into pin 17. The standard TIT probe PN M111-T with a #48 clamp is placed in the exhaust stack accumulator to a maximum depth of 1/2 inch and approximately 4 inches from the turbine inlet if possible, on the waste-gate side of the turbine. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 11 of 37 Rev D Date 3-21-08 11.1 TIT for second Turbine Inlet Temperature Use the J1 connector harness 700200 and insert the yellow wire into the connector pin 18 and the red wire into pin 17. The standard JPI TIT probe P/N M-111-T with a special clamp is placed in the exhaust stack accumulator to a maximum depth of 1/2 inch and approximately four inches from the Turbine inlet if possible, on the waste gate side of the turbine. 11.2 Using the Factory original TIT Probe The factory installed TIT probe (K-calibration) is compatible with the JPI EDM-900/930System. Connect the JPI wire marked TIT in parallel with the factory probe noting color polarity. See the EDM-900/930Pilot’s Guide for the factory TIT probe calibration procedure only if you want to have the EDM and the factory probe to operate off of one TIT. Replacement probes should be purchased per part number from the aircraft manufacturer. If you choose to use only the EDM-900/930TIT display you may remove the factory installed TIT indicator and leave the TIT probe installed. Connect the JPI wire marked TIT directly to the probe noting color polarity. The TIT probe should now have only the JPI leads attached to it. No calibration of the EDM-900/930is necessary. 12. Cylinder Head Temperature (CHT) Probe Installation Use the J2 connector harness 700700 or 700702 labeled C1 through C4 or C6. The JPI probe is a bayonet probe P/N 5050-T that has a captive 3/8-24 boss that is screwed into the head of each cylinder. For Indicator replacement, replace your existing CHT probe and adapter, a bayonet or screw in type with one supplied by JPI. Install the probe on the same cylinder from which you removed the original equipment probe. Your current CHT probe is installed in the hottest cylinder as determined by the airframe manufacturer. Alternate method To keep the existing CHT gage functional install a JPI PN 5050-A adapter probe. 13. Outside Air Temperature (OAT) Probe Installation Use the J1 connector harness 700200 labeled OAT. All wiring must be type K thermocouple wire. Do not splice ordinary copper wire in any temperature probe circuits. aircraft sheet metal shield tube used to secure probe probe Install the OAT probe, PN 400510 washer washer in the airframe manufacturer’s recommended location. If this information is not available, place the OAT probe in clean airflow such as in a cabin air scoop or below the underside of the wing away from engine heat or exhaust. In this case it is recommended that the installation be done similar to the antenna installation instructions of AC 43.12-2a Acceptable Methods, Techniques and Practices. The outside aluminum shield tube is used to both hold the probe in place and shield it from radiated heat from the sun. The OAT option is displayed as an independent digital temperature bar graph such as "75.” 14. Induction Air (IAT), Compressor Discharge Temperature Probe Install (optional) Use the J1 connector harness 700200 and insert the yellow wire into the connector pin 3 and the red wire into pin 4. All wiring must be type K thermocouple wire. The Induction Air Temperature probe, (IAT), is installed just after the inter-cooler and the Compressor Discharge Temperature (CDT) just before the inter-cooler. The probe is the same as an EGT probe and installed similarly to an EGT probe. A large clamp is supplied to fit around the air duct leaving the inter-cooler. Alternately a 1/8 NPT fitting is available. IAT option is displayed as an independent digital temperature like "125 IAT". On non-turbo engines the IAT in reality is the Carburetor temperature and displayed as “34 CRB.” FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 12 of 37 Rev D Date 3-21-08 15. Carburetor Probe Installation (optional) Use the J1 connector harness 700200 and insert the yellow wire into the connector pin 5 and the red wire into pin 6. All wiring must be type K thermocouple wire. Do not splice ordinary copper wire in any temperature probe circuits. Locate the access hole (1/4-24 thread) in the carburetor near the butterfly valve. Remove the screw plug now in that hole and screw the CRB probe into the carburetor throat. No drilling or machining of the carburetor is necessary. 16. Oil Temperature Probe Installation The sensor port is a standard 5/8-18 thread for both the Continental and Lycoming engines. Probe PN 400509 is a complete assembly using type K thermocouple wire (red/yellow). Connect the wire marked oil temperature observing polarity. Wire length has no effect on the readings. Oil temperature will be displayed as an independent temperature digital and bar-graph. Check with engine manufactures proper location for oil temperature. Check for oil leaks before first flight. 17. Oil Pressure Sensor Installation Use the J3 connector harness 790420 labeled OIL-P for a VDO pressure sensor (shown in diagram below). Use J4 for a Sensym pressure sensor (not shown). Oil pressure sensor mount using an aluminum clamp MS21919. Mount to firewall. Mount the pressure sensor to the pressure line using a flexible hose and fittings (not supplied) as depicted in the drawing below. Use aluminum clamp to mount the pressure sensor to firewall. Do not mount the sensor directly to AN-910-1D 1/8 NPT coupling AN-816-4D 1/8 NPT to flared MIL-H-8794 hose MS-24587 fitting (AEROQUIP 491, 2 req'd) to engine fitting pressure sensor flexible tube 6 inch (AEROQUIP 303) mount using MS21919 -DG24 1.5 inch clamp DO NOT MOUNT SENSOR DIRECTLY TO ENGINE Transducer supplied by JPI, all other hardware supplied by installer. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 13 of 37 Rev D Date 3-21-08 the engine. Connect the other end of the hose to the engine manufacturer’s recommended location for engine oil pressure. 17.1 Alternate method of installation keeping the original sensors in the aircraft operational The oil pressure sensor is teed off the oil pressure line feeding the original aircraft gage or the oil pressure switch is removed and the sender is installed in that location. 18. Fuel Pressure Sensor Installation Use the J5 connector harness 790719-X labeled FUELP. Mount the pressure sensor to the pressure line using a flexible hose and fittings (not supplied) as depicted in the drawing below. Use Aluminum Clamps MS21919WDG25, or WDG14 to mount the pressure sensor to engine mount structure or firewall. Do not mount the sensor’s directly to the engine. Connect the other end of the hose to the existing pressure line. Later, you will connect the pressure sensor to the four pressure sensor wires through the supplied 4-pin connector. Part No. 790719() required for Carburetor engines OR Transducer PN 3060-17 for injected engines. PN 3060-17 is a resistive and requires two wires with no polarity. For Sensym sensor (shown below), crimp the four pins of the female Molex connector to the harness, matching the wire colors. Secure to firewall with Aluminum Clamp MS21919 WDG14. For injected engines use clamp MS21919WDG 25. A N -9 1 0 -1 D 1 /8 N P T c o u p lin g A N -8 1 6 -4 D 1 /8 N P T to fla r e d M IL - H - 8 7 9 4 h o s e M S - 2 4 5 8 7 fittin g ( A E R O Q U IP 4 9 1 , 2 r e q 'd ) to e n g in e fittin g A E R O Q U IP 3 0 3 F le x h o s e D O N O T M O U N T S E N S O R D IR E C T L Y T O E N G IN E 1 FP FP FP FP G ND BLK S IG + W H T PW R RED S IG - G R N C o n n e c t to P 5 c o n n e c to r h a r n e s s 7 9 0 7 1 9 -X 18.1 Alternate method of installation keeping the original sensors in the aircraft operational The fuel pressure sensor is teed of the pressure line feeding the original aircraft pressure gage. Firewall Fuel Pressure Sensor from engine T-fitting Fuel pressure or fuel flow gage FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 14 of 37 Rev D Date 3-21-08 19. Ammeter Shunt Installation Use the J5 connector harness 790719-X labeled AMP+ and AMP-. Connect the harness leads using ring terminals to the smaller terminal screws on the side of the shunt. 19.1 Charge/Discharge configuration The shunt can be installed between the master contactor and the main bus in which case it will be in the ammeter configuration showing battery charge and discharge. Be sure that the positive side of the shunt is connected to the main bus in the ammeter configuration. The alarm will be triggered by a discharge condition. Master switch contactor Alternator F G B - BATT + Master switch Bus + Starter external shunt Starter solenoid Ammeter Configuration 19.2 Load Meter Configuration Alternatively the shunt can be installed between the alternator output and the main bus in which case it will be the load meter configuration showing alternator load (positive only). Be sure that the negative side of the shunt is connected to the main bus in the load meter configuration. There is no alarm. Master switch contactor Alternator F G B - BATT + + Master switch Bus external shunt Starter Starter solenoid Load Meter Configuration FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 15 of 37 Rev D Date 3-21-08 20. General Fuel Flow Transducer Installation Use the J4 connector harness 700709 labeled FFSIG (white), FFPWR (red), and FFGND (black). If no previous fuel flow transducer is installed, install transducer per APPENDIX-A Report 503 FUEL FLOW TRANSDUCER INSTALLATION. The EDM-900/930 receives signal from any installed FloScan Transducer with the following FloScan P/N’s embossed on to the top of the transducer. The K-Factor is marked on the side of the Transducer and on a white ticket. Wire per drawing 790744, Route the JPI wires along the existing wiring bundle lacing every foot. The EDM is approved to work with the following Shadin equivalent PN. FloScan PN 201-A 201-B 201-C 231 Shadin equivalent PN 680501/680600 680503 Before connecting any hoses to the transducer, thoroughly clean them and insure they are free of any loose material. Never pass air pressure through the transducer or use Teflon tape/pipe cement; damage will occur. Use only steel fittings supplied never use aluminum fittings on transducer. Remove the transducer cap plugs only when ready to install the hoses. Note the direction of fuel flow marked on the transducer. Fuel must flow in this direction. Reverse flow installations will read ½ the required flow. Mount the transducer with the three wires pointing up. The K-factor is printed on the side of the transducer and on a tag. Write down the K-factor here for future reference __________. Aeroquip 900591B Clamp MS 21919 Clamp as required Cut slit in fire sleeve up Fittings 1/4 NPT. Do NOT use aluminum fittings Aeroquip 303 hose Transducer OUT IN to carburetor, flow divider, or fuel injector 6 inches maximum from support Aeroquip Fire Sleeve AE102/62-24 from fuel tank, throttle body or engine driven fuel pump. The EDM-900fuel flow transducer receives signal from any installed 201 or 231 transducer with either of these part numbers embossed on to the top of the transducer. For specific engine Installations see Appendix Report 503 21. Fuel Level Sender Wiring Types JPI strongly recommends replacing the fuel quantity sensors when installing the EDM. The EDM-930 supports fuel level sensors for directly reading the fuel level in aircraft fuel tanks. The EDM-900/930 contains a fuel table which contains calibration values to convert sensor readings into fuel quantity in the graphs section display. The fuel quantity gauges will not be present on the display until the fuel table for your aircraft has been installed on the Key Card by JPI. The EDM-900/930 function with Resistive/voltage (Change in Resistance or voltage) and Capacitance (Change in frequency) type fuel level senders. In some cases the resistive reading is converted into voltage before it enters the EDM 21.1 Capacitive Sender Use the J5 connector harness 700719-2 with two gray cables (3 wire) labeled LEFT TNK and RT TANK. After senders are installed, connect them to the J5 FP/FQ/AMP wiring harness as shown below (only the right tank FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 16 of 37 Rev D Date 3-21-08 sender is shown for illustration purposes). Trim the pair of gray cables labeled LEFT TNK and RT TANK to length, then crimp the three female contacts onto the harness wire, and insert them into the connector housing. Connect this to the capacitive sender pod cable and connect the white wire of the pod cable to the center, insulated terminal on the sender, and the black wire to the terminal mounted on the metal body on the sender. Repeat for the other tank sender. “FUEL LEVEL CAPACITANCE ” the readings will be in HZ. 21.2 Resistive Sender – EDM-900/930 as Fuel Level indicator Disconnect the fuel level senders from the aircraft’s existing wiring harness, and connect them to the JPI supplied harnesses as described below. Make sure they do not have voltage on them before connecting to the EDM. Use J5 connector harness 790719-3 with two white/black wire pairs labeled LEFT TNK RES and RT TANK RES. On installed sensors connect them to the J5 FP/FQ/AMP wiring harness as shown below. Connect the white wire to the signal terminal and black wire to the ground terminal of the corresponding resistive fuel level sensor. “FUEL LEVEL RESISTANCE ” the readings will be in Ohms. Resistive Harness PN 790719-3 21.3 Resistive Sender – EDM-900/930 as supplemental Fuel Level indicator Use J5 connector harness 790719-3 with a small black box just after the connector has two white/black wire pairs labeled LEFT TNK RES and RT TANK RES. Disconnect the white wires going to the factory gages and mark left and right. Connect the appropriate white wire in the harness to the white wire signal terminal and black wire to the ground terminal of the corresponding resistive fuel level sensor. A good ground is very important and so get as FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 17 of 37 Rev D Date 3-21-08 close as possible to the fuel sender. Make the connection on the existing fuel level gage terminals. When using the EDM to calibrate the sender you will see “FUEL LEVEL VOLTAGE ” the readings will be in volts .5 to 4.5. 21.4 Fuel Tank Setup The EDM-900/930 supports fuel level sensors for directly reading the fuel level in aircraft fuel tanks. The EDM-900/930 contains a fuel table which contains calibration values to convert sensor readings into fuel quantity in the graphs section display. The fuel quantity gauges will not be present on the display until the fuel table for your aircraft has been installed on the Key Card by JPI, USD and REM will be displayed. Use the following procedure for determining the values that JPI will install into the fuel tables on your Key Card. The most accurate way to enter calibration values into the fuel table is to completely drain the aircraft fuel tanks and record readings while filling each tank from empty to full in incremental steps. Note: The owner of the aircraft is responsible for assuring the correct contents of the fuel tables. 21.4.1 Determining Calibration Points First determine how many fuel level calibration points you wish to use. If your tanks or fuel senders are non-linear, use more points. Otherwise use just 2. Select the row in the table below to determine how to calibrate your fuel level indicator. The following is the procedure to initially calibrate your fuel senders. You should only have to do this once. You will determine the 2 to 5 fuel level calibration points for one tank and write them in the chart below. These values will be entered using the procedure, Error! Reference source not found., in the next subsection. Left fuel level calibration point Left Cal L1 L2 L3 [ ][ ][ ][ ] [ ][ ][ ][ ] [ ][ ][ ][ ] Right fuel level calibration point Left Fuel [ 0] [ 0].[ 0]* [ ] [ ].[ ] [ ] [ ].[ ] R1 R2 R3 Right Cal Right Fuel [ ][ ][ ][ ] [ ][ ][ ][ ] [ ][ ][ ][ ] [ 0] [ 0].[ 0]* [ ] [ ].[ ] [ ] [ ].[ ] * unusable fuel level is entered as 00.0 NEVER add or remove fuel from the aircraft when the master switch is turned on. 21.4.2 Setting Fuel Calibration Points The fuel quantity gauges will not be present on the display until the fuel table for your aircraft has been installed on the Key Card by JPI. Use the following procedure for determining the values that JPI will install into the fuel tables on your Key Card. The most accurate reading come from the installed EDM-930. Inform JPI if the readings were taken off of the EDM or a digital volt meter. Note: Before you install the EDM-930 you can take readings with an Ohm Meter. If you feel the factory Fuel Level gages were accurate you can disconnect the aircraft fuel level transducer and in its place, place an Ohm Box. Adjusting the Ohm Box to get the aircraft fuel level needle to a specific location and then reading the ohms, thus creating a table. The most accurate method is using the EDM system to measure. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 18 of 37 Rev D Date 3-21-08 Turn OFF the aircraft master switch 1 Empty left then right tanks, putting back the unusable fuel. (first fuel level calibration point) Hold the right-most button while turning ON master switch, and see one of three messages: 2 1. Resistive Fuel Level 2. Fuel Level Voltage 3. Capacitive Fuel Level With the left and right tanks empty or at unusable fuel level, write down the displayed calibration values L1 & R1. This is the empty (0) fuel level. You will see typical reading like: LEFT TANK READING RIGHT TANK READING 148.8 OHMS or 2.55 volts or 4532 Hz 151.8 OHMS or 2.45 volts or 4123 Hz Turn OFF the aircraft master switch 3 Add fuel to the left and right tanks and bring it up to the second fuel level calibration point level (or full for a two point calibration) Make sure the tank is full. Some aircraft seem full but can take much more fuel by filling slowly. Hold the right-most button while turning ON master switch. 4 With the left and right tanks at the second calibration point, write down the displayed calibration values L2 & R2 and the amount of fuel now in each tank. For a 2 point calibration, stop here. Turn OFF the aircraft master switch 5 Add fuel to the left and right tanks and bring it up to the third fuel level calibration point level (or full for a three point calibration) Hold the right-most button while turning ON master switch. 6 With the left and right tanks at the third calibration point, write down the displayed calibration values L3 & R3 and the amount of fuel now in each tank. For a 3 point calibration, stop here. Turn OFF the aircraft master switch. 7 Add fuel to the left and right tanks and bring it up to the fourth fuel level calibration point level (or full for a four point calibration) Hold the right-most button while turning ON master switch. 8 With the left and right tanks at the fourth calibration point, write down the displayed calibration values L4 & R4 and the amount of fuel now in each tank. For a 4 point calibration, stop here. Turn OFF the aircraft master switch 9 Add fuel to the left and right tanks and bring it up to full for the fifth fuel level point calibration point level. Shake the aircraft to make sure you are full. On some aircraft full is not at the filler cap point. Hold the right-most button while turning ON master switch. 10 With the left and right tanks at the fifth calibration point, write down the displayed calibration values L5 & R5 and the amount of fuel now in each tank (fuel tanks). 22. GPS Interface Use the J4 connector harness 790709 labeled RS232 OUT TO GPS (white) and RS232 IN FROM GPS (gray). Refer to the Manufactures GPS manual for the required pin connections on the GPS. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 19 of 37 Rev D Date 3-21-08 23. Manifold Pressure (MAP) Sensor Aeroquip 303-4 hose with 491-4 fittings Fire Wall AN832-4 or AN833-4 Aeroquip 303-4 with 491-4 fittings to engine OR PN 604017 Screw a AN816-4D (flared to pipe thread) into the Aeroquip 303 hose to and from the bulkhead fitting an 832-4 as shown below if not already installed from the aircraft factory MAP gage. 23.1 Alternate method of Manifold pressure transmitter installation in aircraft using existing Manifold Pressure gage For the JPI sensor use the J3 connector harness 790420 and connect the 4 leads using the supplied 4-pin connector and pins. Install a T-fitting in the aircraft’s MAP gage line in the cockpit near the MAP gage. Install the JPI MAP sensor P/N 604010 on the T-fitting. The MAP sensor uses a 1/8 NPT fitting. MAP SIG- GRN MAP PWR RED MAP SIG+ WHT MAP GND BLK MAP Sensor 1 connector from engine T-fitting MAP gage FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 20 of 37 Rev D Date 3-21-08 23.2 Manifold Pressure Calibration The manifold pressure must be calibrated to the ambient air pressure. Enter the current ambient barometric pressure. The engine must not be running. This setting is not the same as the altimeter setting that you receive from ATIS or Unicom. It will vary with field elevation. Use the chart below to calculate the MP FACTOR. Multiply this MP FACTOR by the altimeter setting that you receive from ATIS or Unicom. For example if the field elevation is 1700 ft and the altimeter setting is 30.1, the MP FACTOR is 0.9400 from the table. Multiply 30.1 x 0.9400 to get the ambient MP of 28.29. Field Elev. MP FACTOR -500 -400 -300 -200 -100 0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1.0182 1.0145 1.0109 1.0073 1.0036 1.0000 0.9964 0.9928 0.9892 0.9856 0.9821 0.9785 0.9750 0.9714 0.9679 0.9644 0.9609 0.9574 0.9539 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 3100 3200 0..4 0.9469 0.9435 0.9400 0.9366 0.9332 0.9298 0.9264 0.9230 0.9196 0.9162 0.9129 0.9095 0.9062 0.9028 0.8995 0.8962 0.8929 0.8896 3300 3400 3500 3600 3700 3800 3900 4000 4100 4200 4300 4400 4500 4600 4700 4800 4900 5000 5100 0.8863 0.8830 0.8798 0.8765 0.8733 0.8700 0.8668 0.8636 0.8604 0.8572 0.8540 0.8508 0.8477 0.8445 0.8414 0.8382 0.8351 0.8320 0.8289 5200 5300 5400 5500 5600 5700 5800 5900 6000 6100 6200 6300 6400 6500 6600 6700 0.8258 0.8227 0.8196 0.8165 0.8135 0.8104 0.8074 0.8043 0.8013 0.7983 0.7953 0.7923 0.7893 0.7863 0.7833 0.7804 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 21 of 37 Rev D Date 3-21-08 24. RPM Sensor installation Use the J3 connector harness 790420 and connect the 3 leads using the supplied 3-pin connector and pins. There are three types of magnetos commonly in use. You must have the correct RPM sensor for the magneto installed in the aircraft. The following part numbers apply: Slick -4000, -6000 use JPI P/N 420815. For the Bendix -1200 use P/N 420815. Dual magnetos use JPI PN 420810. Mount the sensor as shown in the appropriate diagram below. S lic k M a g n e to s engine engine B e n d ix M a g n e to s C on nec tor to h arness C o nne cto r to harne ss S lic k 60 00, 4000 series n o n -p ressu rized B en d ix -20 , -2 1, -200, 120 0 series n o n -p ressu rized J P I 4 20 8 15 -1 J P I 4 20 8 15 -2 M ou nt s ens or s ide of b rac ket tow a rds m a gne to b ody M ou nt se nso r s ide o f b rack et tow a rds m ag neto bo dy, pos ition ed over th e m agn et a rm atu r e S ens or ring m u nted un der ve nt p lug. S te m a t rig ht ang les to m agn eto cen ter line engine engine T P O TOP po sition lim it po sition lim it C on nec tor to h arness A lte rna te bra cket loca tion A ltern ate bra cke t loc ation s B en d ix 12 00 se rie s p ressu rized V e nt p lug S p ace r rin g S ens or ring bracke t M agn eto bod y JP I 42 08 07 M o unt sen sor side of bra cke t tow ard s m a gne to b ody C o nne cto r to harne ss S lick 6000, 40 00 se rie s p ress u rized J P I 4 20 8 09 S e nso r m ust be m o ving o verm a gne t arm a ture engine O T P engi ne R em ove this to sc m orew unt b rac seknsor et B e n d ix D u a l M ag n eto S lic k 60 0 s eries R P M S IG G R N 1 RPM GND BLK RPM PW R RED re v M ar 2004 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 22 of 37 Rev D Date 3-21-08 25. EDM-900/930 Specifications and Limitations The following parameters must be customized for the aircraft into which the EDM-900/930 is installed. Factory set limits or default values for EDM-900/930 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. TIT 1650 F CHT 450 F Oil Temp Low 90 F Oil Temp HI 230F Oil Press low 15 psi Oil Press Hi 100 psi Vacuum 0- 15”hg RPM 2700 Limit and range RPM set to cyl 6 Map 32 In hg HI Map setting 29.90 In Hg Fuel Pressure Hi 35 psi Injected Fuel Pressure Lo 15 psi Injected Fuel Pressure Hi 8 psi Carb Fuel Pressure Lo .5 psi Carb Fuel Flow 24 GPH K-factor 29.99 Carburetor filter smoothing 1 Ammeter configuration (load or charge-discharge). Load HC-120 (% of HP) Fuel Level Resistive/Capacitive Low fuel 10 Gal Low time 45 Min Main tank 75 gallons Aux tank 0 GPS set at GARMIN Diff 500 degrees CLD 60 degrees per minute Amps limit 100 amps Record time, 6 sec intervals Hobbs on at 1000 RPM TSO-C43 TSO-C43 TSO-C43 TSO-C43 TSO-47 TSO-47 TSO-47 TSO-C49 TSO-C49 TSO-C45 TSO-C45 TSO-47 TSO-47 TSO-47 TSO-47 TSO-C44 NON TSO NON TSO TSO-55 TSO-C43 TSO-C43 NON TSO NON TSO NON TSO On 14 vdc systems during start-up the EDM may reset it self. This is normal due to extremely low battery voltage. The conditions and test required for TSO approval of this article are minimum performance standards. It is the responsibility of those desiring to install this article either on or within a specific type or class of aircraft to determine that the aircraft installation conditions are within the TSO standards. The article may be installed only if installation of the article is approved by the Administrator. The functions of Volts, Amps, and Horse Power were tested to DO-160D and DO-178B, but not TSO’d since no TSO exist for these functions. Deviation granted for TSO-C49b to include digital display and sensor. All TSO required probes, transmitters and sensors also tested to DO-160D. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System 26. Component Parts P.N. 790900 (-A,-B,-C) Display and Indicator EDM-900/930 EGT probe KIT PN 128000 TIT probe with option KIT 120000 CHT probe KIT PN 126000 OAT probe with option KIT 122000 IAT probe with option KIT 130000 Carb temp probe if required Oil probe with option KIT 124000 Oil pressure sender Fuel pressure sender Ammeter shunt Fuel Flow transducer Fuel Level sender option MAP P/N 604010 RPM one of P/N 420815-1,-2 26.1 Single engine -4Cyl -6Cyl 1 1 4 6 1 1 4 6 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Component Parts List for EGT (PN 128000), TIT (PN 120) Probe 1 Thermocouple type K probe PN M-111 1 Stainless Steel Clamp Thimble 1 Stainless Steel Exhaust Seal Washer 1 Stainless Steel Screw Type Clamp 2 Ring Terminals 2 Screws and nuts 6-32 X 1/4 1 Fiberglass tube 1/2" X 4" 26.2 Component Parts list for CHT (PN 126000) probe 1 Bayonet Probe Thermocouple type K Spring loaded PN 5050-T 1 Or Gasket thermocouple probe type K PN MM-113 2 Ring Terminals 2 Screws and Nuts 6-32 X 1/4" 1 Fiberglass tube 1/2" X 4" 26.3 Component Parts list for OAT (PN 122000) probe 1 P/N 400510, OAT probe 2 Ring Terminals 2 Screws and Nuts 6-32 X1/4" Fiberglass tube 1/2" X 4" 26.4 Component Parts list for IAT/CARB (PN 121000) probe 1 P/N 400128, IAT/CARB probe 2 Ring Terminals 2 Screws and Nuts 6-32 X1/4" 1 Fiberglass tube 1/2" X 4" Report No 908 Page 23 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 24 of 37 Rev D Date 3-21-08 26.5 Component Parts list for OIL probe 1 P/N 400509 OIL probe 2 Ring Terminals 2 Screws and Nuts 6-32 X 1/4" 1 Fiberglass tube 1/2" X 4" 26.6 Component Parts list for VDO Oil Pressure sensor 1 P/N 3060-18, Oil pressure sender two wire 2 Ring Terminals 26.7 Component Parts list for Sensyn Oil Pressure sensor 1 P/N 790775-1, Oil pressure sender four wire 1 4-pin male connector housing 4 male crimp pins 1 4-pin female connector housing 4 female crimp pins 26.8 Component Parts list for Sensyn Fuel Pressure Sensor 1 P/N 790775 Fuel pressure sensor 1 4-pin male connector housing 4 male crimp pins 1 4-pin female connector housing 4 female crimp pins 26.9 Component Parts list for ampere shunt 1 P/N 159920 100 amp shunt 2 Ring Terminals 26.10 Component Parts list for Fuel Flow Transducer 1 fuel flow transducer, 201 or 231 PN 700900-1,-2 8 inches of 1.5”dia fire sleeve 1 3-pin connector housing 3 female pins 2 AN816-4-4 fittings 26.11 Component Parts list for JPI MAP sensor 1 P/N 604010, MAP sender 26.12 Components Parts list for RPM sensor P/N depends on Magneto make and model Bendix magneto -20,1200 P/N 420815-1 Slick magneto 4000 or 6000 P/N 420815-2 27. Weight and Balance Data Indicator PN 790000(-A) EDM-900 Indicator PN 790000(-B) EDM-. Indicator PN 790000(-C) EDM-930 EGT / TIT / CDT / IAT / OAT probe CHT / Oil Temperature probe 4/6 Cylinder Harness 8 ft. RPM and MAP Fuel Pressure Sender Oil Pressure Sender 2.0 Lbs 1.8 Lbs 3.0 Lbs 2.0 oz. each / 0.125 lbs 1.5 oz. each / 0.094 lbs 14.0 oz. each / 0.88 lbs 1.5 oz each / .094 lbs 3.9 oz each / 4.4 oz each / FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Harness each Report No 908 Page 25 of 37 Rev D Date 3-21-08 1.0 Lbs 28. Pilot Programmable Mode 28.1.1.1 Pilot Programming Using EzConfig JPI provides a configuration program that runs on an MSWindows PC, called EzConfig. See the www.jpinstruments.com web site to download. Follow the instructions in the EzConfig documentation to change these assignments. 28.1.1.2 Pilot Programming without EzConfig To start the Pilot Program procedure, simultaneously hold the STEP and LF buttons for five seconds. You will see the word PROGRAM for two seconds and then the sequence shown in the chart below. Tap the STEP button to advance to the next item in the list. Hold the STEP button to step back to the previous item. Tap the LF button to select alternate values of that item. Simultaneously hold both STEP and LF to exit. STEP advances next item LF sequences through these values PROGRAM FUEL N RATE 4 FILL ? N 0…9 OAT F OAT+0 EGT I?N HPC I25 OAT F ⇔ OAT C OAT-I0 … OAT+I0 EGT I?N ⇔ EGT I?Y 70 HP HPC= I25 Comments Stays on for two seconds. Tap LF to change fuel status. Exits program mode when done. Index rate (pause time in seconds) in the Automatic Mode. 0 disables the Automatic Mode. To calibrate the OAT ±10°, hold both the STEP and LF buttons simultaneously for five seconds, which will proceed to the next step. Otherwise the next step will be skipped. This step will be normally be skipped. Adjust the indicated temperature up or down by up to 10°. For example, OAT+3 adjust the OAT 3° higher. Y—Yes—sets the digital display to one-degree resolution; N—No—sets 10°. (10° resolution is easier to interpret the EGT’s.) %HP display will change when HP constant is adjusted. Hold STEP and LF for 5 seconds until you see ADJUST to set the HP calibration. Tap STEP to continue to the next step. See page 26 To adjust the MAP, hold both the STEP and LF buttons simultaneously for five seconds, which will proceed to the next step. Otherwise the next step will be skipped. MAP 29.9 MAP 20 32 Adjust the MAP. See page 26 Adjust the instrument’s K-factor to match the fuel flow transducer K-factor. See page 26 KP 29.90 TR IP? N TR IP? N ⇔ TR IP? Y N—No—Upon informing the EDM that you refueled the aircraft, reset total fuel used to 0. Y—Yes—accumulate total fuel used rather than reset to 0 at each refueling. See page 26 HOBS VAL 2424 ENG⇔ 25 EDM⇔ 3567 FRM END? Y Displays the engine hours and airframe hours. END? Y STEP exits the pilot programming mode. LF reenters pilot programming mode. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 26 of 37 Rev D Date 3-21-08 28.1.2 Programming the Horsepower Constant You must adjust the HP Constant once for your aircraft. You must perform this adjustment in the air while the aircraft is in flight between 5,000 and 8,000 feet MSL. 1. Enter the pilot program mode by simultaneously holding the STEP and LF buttons for five seconds. 2. Tap STEP repeatedly until you see—for example— HPC = I25. Then hold both the STEP and LF buttons display until you see ADJUST, followed by HPC= I25. The adjustment range for the HP Constant is 45 to 180. 3. Set the MP and RPM per your POH to 70 percent power. Let conditions stabilize. 4. Change the HP reading on the EDM-900 to 70 percent by adjusting the HP constant in the lower display by holding or tapping the LF button. Percent HP should be close to 100 percent during takeoff at sea level. 5. Tap the STEP button to proceed to the next step. 28.1.3 Programming the MAP Sets the manifold pressure calibration (an sets the Carbureted fuel pressure zero points). You may need to correct the MAP based on the altimeter setting at a sea level airport. 1. Enter the pilot program mode by simultaneously holding the Step and LF buttons for five seconds. 2. Tap Step/OK repeatedly until you see—for example— HPConstant=125. Then hold both the first two buttons Step/OK and Change buttons display until you see Adjust, followed by HP Constant=125. 3. Again, Hold both the two buttons, Step/OK and Change buttons display until you see ADJUST, followed by MAP+0. The adjustment range for the MAP is ±3.0 in Hg. As you adjust the MAP up or down you will see a change in the MAP gage under RPM. When you see the correct setting stop. 4. Tap the Step/OK button to proceed to the next step or hold both buttons again to exit setup. Do this one time and only if the MAP on your manifold pressure gauge doesn't match the MAP shown on the EDM-900 You must do this on the ground with the engine turned off. A. Absolute calibration: the table below shows the MAP for a given field elevation (down the left side of the table) and altimeter setting (along top row of the table). Find the entry in the table most closely matching your field elevation and current altimeter setting. Interpolate if necessary. Alt setting-> field elev. 0 1000 2000 3000 4000 5000 6000 7000 29.0 29.2 29.4 29.6 29.8 29.9 30.0 30.2 30.4 30.6 30.8 31.0 29.0 28.0 27.0 26.0 25.0 24.1 23.2 22.4 29.2 28.2 27.1 26.2 25.2 24.3 23.4 22.5 29.4 28.4 27.3 26.3 25.4 24.5 23.6 22.7 29.6 28.5 27.5 26.5 25.6 24.6 23.7 22.8 29.8 28.7 27.7 26.7 25.7 24.8 23.9 23.0 29.9 28.8 27.8 26.8 25.8 24.9 24.0 23.1 30.0 28.9 27.9 26.9 25.9 25.0 24.0 23.1 30.2 29.1 28.1 27.1 26.1 25.1 24.2 23.3 30.4 29.3 28.3 27.2 26.3 25.3 24.4 23.5 30.6 29.5 28.5 27.4 26.4 25.5 24.5 23.6 30.8 29.7 28.6 27.6 26.6 25.6 24.7 23.8 31.0 29.9 28.8 27.8 26.8 25.8 24.8 23.9 Unless your airfield is close to sea level, do not set MAP to the local altimeter setting since that setting is the pressure corrected to sea level, and is not the same as your field elevation pressure. Tap or hold the LF button to change the MAP value. Tap the STEP button to proceed to the next item. 28.1.4 K factor The K factor is shown on the fuel flow transducer as a four-digit number, which is the number of pulses generated per gallon of fuel flow. Before installing the transducer, write down the K factor here _________. To enter the number, FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 27 of 37 Rev D Date 3-21-08 move the decimal point three places to the left. For example if the K factor on the fuel flow transducer is 29,123, enter 29.12 in the K factor parameter. If the K factor is increased, the indicated fuel flow will decrease, and vice-versa. When the K factor is changed during a trip, calculations of fuel used, fuel remaining and time to empty are not retroactively recalculated. 28.1.4.1.1 Fine Tuning the K factor The K factor shown on the fuel flow transducer does not take into account your aircraft’s particular installation. Fuel hose diameters and lengths, elbows, fittings and routing can cause the true K factor to be different from that shown on the fuel flow transducer. You must use the following procedure to fine tune the K factor. 1. Make at least three flights of about two to three hours each. Note the actual fuel used (as determined by topping the tanks) and the EDM-900 calculation of the fuel used for each flight USD. Flight 1 2 3 Total Fuel USED shown by EDM (total tank - REM) Actual fuel used by topping tanks 2. Total the EDM-900 calculated fuel used and the actual fuel used. 3. Record the current K factor here ____________________ and in the table below. 4. Calculate the New K factor as follows: New K factor = (EDM fuel used) x (Current K factor) (actual fuel used) ) x ( New K factor = ( ( ) ) Every time you fine tune the K factor, change it by only half of the amount calculated above, and record the measurements here: EDM actual Current New K factor Pilot’s Date fuel used fuel used K factor initials = x/ 28.1.4.2 Programming the K factor This procedure is different than for setting other parameters. 1. If you haven’t already done so, start the Pilot Program procedure, by simultaneously hold the STEP and LF buttons for five seconds. You will see the word PROGRAM, followed by FUEL N. 2. Again, simultaneously hold the STEP and LF buttons for five seconds. You will the word FACTORY, followed by RESET? N. 3. Tap STEP button to advance to the FFLW? N screen. FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 28 of 37 Rev D Date 3-21-08 4. Tap LF to enter the fuel flow submenu. 5. Tap STEP repeatedly until you see KF = 29.90 (for example) 6. Hold both the STEP and LF buttons simultaneously for five seconds. The first digit flashes (shown here as a larger digit only for illustration purposes): 29.90 7. Tap or hold the LF button to change flashing digit: I 9.90 8. Tap STEP button for next digit (hold STEP for previous digit): I 9.90 9. Tap or hold the LF button to change flashing digit: I 8.90 10. Tap STEP button for next digit (hold STEP for previous digit): I8.90 11. Repeat items 9 and 10 for the remaining two digits. 12. Hold STEP and LF buttons simultaneously for five seconds to exit the K factor parameter setup. 13. Tap STEP repeatedly until you see END ? Y, then Tap STEP once more to exit the factory setup mode. 28.1.5 Programming Accumulate Trip Total Accumulate—default is OFF: resets the fuel used to 0 every time you inform the EDM-900 that the aircraft was refueled. With accumulate ON fuel used will not be reset to 0 when you inform the EDM-900 that the aircraft was refueled. Select “No” if you wish to display total fuel used since the last time you informed the EDM-900 that the aircraft was refueled. Select “Yes” to display total fuel used for an extended trip with multiple fuel stops. This selection affects only the USD measurement. During normal operation, to reset the accumulated fuel used display at any time, tap STEP until you see USD. Hold both STEP and LF until the display shows .0 USD. 29. Trouble Shooting 1. A missing column in the display upon start up indicates the continuity check diagnostic routine has found an open line or probe with no connection. An error message will indicate which cylinder to look at. 2. A missing column in the display during flight indicates a reading that is jumping around or incorrect. The probe is removed from the line up to prevent false alarms. 3. A negative reading (-) in front of the number indicates reverse polarity on the red/yellow wire to probe. 4. Using an ohmmeter or continuity checker measure across the probe output leads. A good probe should be around 2- ohms and at the connector to the probe around 20 ohms. 5. Erroneous or erratic readings on one cylinder reading. Swap the suspected probe with a probe from a good cylinder. If the problem goes to the good cylinder the probe should be replaced. If the problem remains the same, it is in the Thermocouple hook-up wiring from the probe to the instrument or it can be in the ring terminals crimped to the wire. Remember to double back on the wire going into the ring terminal. o 6. EGT, large span. Normally aspirated (carburetor) engines at normal cruise display a “DIFF” of 125 to 175 F o spread between cylinders. Injected engines at normal cruise display a “DIFF” 50 to 90 F spread between cylinders. All cylinders are measured by a common circuitry. It is almost impossible not to have identical calibration on all channels. 7. If the temperature reading is changing more than 500°F in one second it should be questioned and a loose wire crimp or probe should be suspected. A malfunctioning probe will automatically be removed from the scan. 8. All EGT or CHT readings seem to high or low or unsteady. Use a DVM (digital voltmeter) to measure the difference between 900SCANNER ground and the engine block ground. If the difference is greater than 0.5 volts FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 29 of 37 Rev D Date 3-21-08 with the alternator charging. Then remove the EDM-900/930ground (Black wire) from the instrument panel and connect it directly to the ENGINE BLOCK for GROUND. 9. OAT readings off by 25 degrees, but oil and CHT readings OK, look for copper wire spliced in line to OAT probe. OAT reading can be fine tuned +/- 5 degrees, see reset procedure. Engine heat could also be the cause. 10. The instrument configures itself automatically for 4 or 6 cylinder engines, 14 or 28 volt electrical systems. 30. Connector Pin Assignments Rear View of EDM-900/930 Showing Connector Locations FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 30 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 31 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System J3 green 1 black 2 red 3 RPM sig RPM 420815-1,-2 1 2 3 RPM ground RPM power red 4 or black 5 or P 2 6 5 6 7 Kav green white 8 green 9 or 4 3 2 1 MAP (Kavlico or UMA) OP(VDO) 306018 MAP 604010 Report No 908 Page 32 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System J4 (15 pin) (25 pin) 1 1 2 2 white 4 white 4 red 5 red 5 black 6 black 6 Data out to GPS Data in from GPS FF 700900-1, -2 OUT IN OP (Kavlico or UMA) red red 9 or red P255 black black 10 or black green green 11 1 green 12 10 15 11 16 white 12 white 17 13 18 gray 14 19 White 15 20 or white OP (Sensym) 790775-1 Right low fuel switch 5 Remote fuel flow alarm light (option) 6 OUT 21 22 23 24 25 Left low fuel switch IN FF2 Power and ground connect to pins 5 and 6 respectively AMPS 2 + 159920 Report No 908 Page 33 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Edm-900/930 Report No 908 Page 34 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 35 of 37 Rev D Date 3-21-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 36 of 37 Rev D Date 2-07-08 FAA Approved Installation Manual for the EDM-900/930 Primary Engine Data Management System Report No 908 Page 37 of 37 Rev D Date 3-21-08 31. Certificate of Compliance, Fuel Level Transmitters • FAA AC 25.981-1B Section 7 states (concerning electrical arc generation, and filament heating energy): • “Electrical transient amplitudes less than 40 volts may be considered less than the potential required to create sparks. In addition …a maximum of 20 microjoules is considered intrinsically safe for fuel quantity indicating systems.” • “… electrical power with the potential to create a filament heating ignition source in the fuel tank should be limited to less than 30 milliamperes RMS …, a factor of safety should be applied to this value when establishing a design limit.” • Circuitry connected to the fuel tank sensor is equivalent to a 5 VDC source in series with a 2200 ohm resistor, with a 0.01 microfarad capacitor in parallel. • The maximum energy stored in the capacitor = ½ C* V^2 = 0.125 microjoule. • The maximum current in the circuit (assuming a short circuit in tank) = V/R = 2.3 milliamperes. The maximum stored energy and current in the JPI EDM-900 / 930/. fuel level circuit are far below recommended minimums. • 23. Instructions for Continued Airworthiness (ICA) There are no field adjustments and or calibration requirements for the EDM-900/930 instrument after initial installation. ICA is not required. Maintenance of nonfunctioning or malfunctioning components is limited to removal and replacement of JPI factory supplied new or repaired components as described in the troubleshooting section of the installation instructions. ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Combined electronic indicating system
- Displays powerplant and aircraft systems operating parameters
- Replaces primary digital and analog instruments
- Includes RPM, MAP, CHT, EGT, oil temperature, oil pressure, fuel pressure, fuel flow
- Supports various fuel level sender types
- Provides remote alarm display
- Auto-dimming display
- Pilot programmable mode
- FAA approved
Frequently asked questions
The EDM-900/930 replaces all previous primary digital and/or analog instruments, including RPM, MAP, CHT, EGT, oil temperature, oil pressure, fuel pressure, and fuel flow.
The EDM-900/930 supports both resistive/voltage and capacitance fuel level senders, allowing for direct reading of fuel level in aircraft fuel tanks.
The RAD is a separate display located in front of the pilot that provides digital cautions and limit excedances when any parameter reaches its preset trigger point. It continuously displays MAP and RPM when no alarms are triggered.