logic 4 addendum

logic 4 addendum
WARNING
LOGIC 4 ADDENDUM
N4 AND N4X MODIFICATION
WARNING
To reduce the risk of SEVERE INJURY or DEATH:
• ANY maintenance to the operator or in the area near the
operator MUST NOT be performed until disconnecting the
electrical power and locking-out the power. Upon completion
of maintenance the area MUST be cleared and secured, at that
time the unit may be returned to service.
• Disconnect power at the fuse box BEFORE proceeding.
Operator MUST be properly grounded and connected in
accordance with local electrical codes. The operator should be
on a separate fused line of adequate capacity.
• ALL electrical connections MUST be made by a qualified
individual.
• DO NOT install ANY wiring or attempt to run the operator
without consulting the wiring diagram. We recommend that
you install an optional reversing edge BEFORE proceeding
with the control station installation.
• ALL power wiring should be on a dedicated circuit and well
protected. The location of the power disconnect should be
visible and clearly labeled.
• ALL power and control wiring MUST be run in separate
conduit.
Application
The N4 and N4X modification is for use in environments requiring
a watertight enclosure.
This addendum is to be used in conjunction with the owner’s
manual included with this operator. Refer to the manual for all
mounting, additional programming and field wiring instructions.
The N4 and N4X modification includes a TEFC motor; dynamic
braking, watertight/oiltight control enclosure; watertight/oiltight
3-button control station; LiftMaster Monitored Entrapment
Protection (LMEP) device, model CPS-UN4; and nickel-plated
chain in lieu of all standard components of the operator. For
service or replacement part requirements, use this addendum in
lieu of those included with the manual.
Leave this addendum and the owner’s manual with the owner.
Troubleshooting
FAULT
POSSIBLE CAUSE
FIX
Door coasts
significantly or
fails to stop.
1. Wiring or AUXCARD is not
properly connected.
2. Dynamic Brake is not
enabled for the operator.
3. Door is too heavy for the
operator or is not properly
balanced.
• Verify the AUXCARD is correctly seated in one of the two expansion
slots on the logic board. Verify all wiring using the wiring diagrams.
• Reprogram the operator to enable the dynamic brake. Refer to
Program the Dynamic Brake.
• Inspect the springs and other aspects of the door to make sure it is
properly balanced and can be easily lifted by the operator.
Operator resets every
time the door stops.
1. Short on transformer
secondary.
• Check the wiring. Verify that the bridge rectifier is not shorted. Verify
that all relays, including the relay on the AUXCARD, have not failed.
Program the Dynamic Brake
The Logic Board (L4) is pre-programmed to control the dynamic
brake. If the logic board is replaced the following programming
steps will be required.
1. Set selector dial to OPTN.
2. Press and release MAS.
3. Press and release MID.
4. Turn the selector dial back to the
desired wiring type.
T
E2
TS
FSTS
D1
DIAG
C2
OPTN
B2
PROG
Electrical Box N4 & N4X
Electrical Box Replacement Kits
NOTE: Optional modifications and/or accessories may add or
remove certain parts from this list.
To order a complete electrical box replacement kit, add a
K- Prefix to the model number of your operator. For example:
N4GH5011L4 (Operator) = K-N4GH5011L4 (Electrical Box Kit)
Electrical Box Replacement Parts
Item Part #
1
03-35711
2
21-7115-1
21-7460-1
21-7575-1
3
K1A6837
4
AUXCARD
5
52C0481
6
6A
42-31247
7
23-10041
8
K72-12515-1
9
10
11
13-10024
K79-15016-1
K72-33192
K72-33258
12
13
14
K75-35815
K75-35816
29-ABC-2
K74-19499
Description
Qty
24Vac Relay
2
Transformer, 115/230V
1
Transformer, 230/460V
1
Transformer, 575V
1
Logic Board (L4)
1
Relay PCB
1
Rectifier
1
Terminal Block
1
MOV’s
2
Limit Switch (only)
1
Limit Switch Kit
Includes: Limit switches,
mounting blocks, mounting
hardware, adjust plate with springs 1
Limit Nut
1
RPM Sensor
1
Limit Shaft Assembly for GH 1/2
to 2 HP
1
Limit Shaft Assembly for GT, GSD,
GH - 3 HP
1
Complete Enclosure, 1 Phase
1
Complete Enclosure, 3 Phase
1
2-Amp Fuse
1
Antenna with Coaxial Cable
1
12
4
1
13
5
2
3
7
6A
6
10
14
Motors
Motor Description
1/2 HP, 115V, 1-PH
1/2 HP, 230V, 1-PH
1/2 HP, 208/230V, 3-PH
1/2 HP, 460V, 3-PH
1/2 HP, 575V, 3-PH
3/4 HP, 115V, 1-PH
3/4 HP, 230V, 1-PH
3/4 HP, 208/230V, 3-PH
3/4 HP, 460V, 3-PH
3/4 HP, 575V, 3-PH
1 HP, 115V, 1-PH
1 HP, 230V, 1-PH
1 HP, 208/230V, 3-PH
1 HP, 460V, 3-PH
1 HP, 575V, 3-PH
2 HP, 208/230V, 3-PH
2 HP, 460V, 3-PH
2 HP, 575V, 3-PH
8
N4
20-1050C-2TLP
N4X
20-1050C-2N
20-3050C-4T
20-3050C-4N
20-3050C-5T
20-1075C-2TLP
20-3075C-5N
20-1075C-2N
20-3075C-4T
20-3075C-4N
20-3075C-5T
20-1100C-2TLP
20-3075C-5N
20-1100C-2N
20-3100C-4T
20-3100C-4N
20-3100C-5T
20-3200C-4TP
20-3100M-5N
20-3200C-4N
20-3200C-5T
20-3200C-5N
9
12
11
How to Order Repair Parts
OUR LARGE SERVICE ORGANIZATION SPANS AMERICA
Installation and service information are available.
Call our TOLL FREE number:
1-800-528-2806
www.liftmaster.com
2
Single Phase Wiring Diagram
1 2
OPEN
3
BR
BR
TB2
3
1
115V WIRING
RD
BK
BR
L1_MOT
2
2
CLOSE
3
TB1
4
1
X4
BRIDGE-
H1
BR
BRIDGE+
BL
X2
L1
L1_RLY
WH
H3
SLOT
1
(SEE NOTE 2)
SLOT
2
SLS
13
13
230V WIRING
BR
12
DEFEAT
COMMON
X3
H2 WH
11
COMMON
MAS
MAS
10
9
MID
TTC
TIMER
ENABLE
COAXIAL CABLE
RADIO
1
2
3
LMEP
X2
11
WH
L2
BK
WH
H3 BK
GN
LIFTMASTER MONITORED
ENTRAPMENT PROTECTION
(LMEP)
9
EDGE
7
BL
BK
L1
L1_RLY
H4 WH
X1
CPS-UN4
10
8
EDGE:
H1 BK
X4
TIMER DEFEAT
12
CLS
MRT
L1_MOT
L1 L2 GND
MOTOR
DIRECTION
MID
3-PHASE
1-PHASE
STD
L2_K3
REV
3
14
YE
24VAC
24VAC
TIMER
TIMER
DEFEAT
OLS
14
CHASSIS
2A
BL
24VAC
POWER
POWER
YE
GN
WH
C8
24VAC
4
WH
BL
C61
WH
BK
L2
H4
DATA C1
L2_SW
BL
BK
BK
X1
BL
H2
WH
L1 L2 GND
X3
BR
CHASSIS
8
OPEN
6
STOP
T
TS
E2
5
DIAG
C2
OPTN
B2
7
OMMON
4
STOP
3
PROG
STOP
5
(SEE NOTE 1)
BR
CLOSE
STOP
CLOSE
6
(SEE NOTE 1)
OPEN
OPEN
CLOSE
FSTS
D1
BR
COMMON
SBC
A
B
1
T8 RD
GY
T1 BL
YE
YE
T5 BK
T5 BK
T8 T2 WH
RD T3 OR
J
INTERLOCK
PU
J
PU
T4 YE
2
T4 YE
T2 WH
SBC
SBC
T1 BL
J
T3 OR
4
3
BR
BR
BL
GY
2
RELAY
RELAY
BR
1
BL
FIELD WIRING BY INSTALLER
115V MOTOR WIRING
BR
230V MOTOR WIRING
GY
(SEE NOTE 1)
5
6
GN
RELAY C
2
3
Motor
1 PHASE
GY
CHASSIS
WH
BR
L1_MOT
YE
YE
BRIDGE+
L2
BRIDGE-
RD
WH
PU
GY
GY
WH
WH
A1
3
R3
1
COM
R1
3
A1
R3
1
R1
WH
BK
WH
L1_RLY
R1 (GND)
RPM Sensor
YE
WH
CLS
RD
A2
4
R4
2
R2
A2
4
R4
2
WH
BK
BR
RD
WH
NO
NC
SLS
Contactor A
B
R2
Contactor BA
R2 (RADIO)
YE
OR
YE
PU
PWR
GND
GND
RPM
PU
PU
R3 (32 Vdc)
GY
L2_K3
RD
BR
OR
WH
L1
BL
COM
NC
NO
PU
NC
NO
WH
L2_SW
NOTE 1: For motors that do not have pilot duty thermal protection and do not have the 2 motor brown wires,
the brown harness wire should be connected to the blue harness wire in the motor junction box.
40-35625-1
NOTE 2: Connect the blue wire directly from transformer to circuit board when no interlock switch is required.
COM
OLS
MAS - Maintenance Alert System Error Codes
MAS LED
1 Blink
2 Blinks
3 Blinks
4 Blinks
5 Blinks
6 Blinks
7 Blinks
8 Blinks
3
DESCRIPTION
MAS triggered (cycles or months)
No RPM input during movement
MRT timed out
Obstruction sensed on closing
Stuck key - button pressed > 2 min.
Invalid option card plugged into
option card receptacles
Fail-safe device failed/not connected
Brownout detected
Three Phase Wiring Diagram
BR
1 2
OPEN
3
BR
(SEE NOTE 1) 230V WIRING
3
1
BR
L1_MOT
TB2
2
BR
H1 BK
X4
X3
BR
1
2
40Vdc-
4
WH
X2
BL
X1
BL
WH
H3
BK
H4
WH
L2
BL
SLOT
(SEE NOTE 2)
C61
1
C8
WH
L3
BL
DATA C1
CHASSIS
BK
L1
H2
RD
40Vdc+
L1 L2 L3
CLOSE
3
TB1
460V WIRING
BR
C61
SLOT
12
DEFEAT
3-PHASE
1-PHASE
MID
MOTOR
DIRECTION
L1_K3
STD
3
PU
REV
4
13
TIMER
TIMER
DEFEAT
OLS
COMMON
TIMER DEFEAT
MAS
MRT
MID
TTC
TIMER
ENABLE
RADIO
1
2
10
LMEP
3
EDGE:
9
10
9
LIFTMASTER MONITORED
ENTRAPMENT PROTECTION
(LMEP)
575V WIRING
BR
OMMON
4
STOP
3
PROG
L2
H2 WH
X2
CLOSE
CLOSE
6
WH
RELAY
RELAY
A
B
1
WH
X1
STOP
STOP
5
2
COMMON
SBC
L3
4
3
CHASSIS
BK
L1
OPEN
OPEN
L3
DIAG
OPTN
B2
7
CLOSE
FSTS
D1
H1 BK
X4
X3
L1 L2
5
L1_MOT
EDGE
8
TS
BL
L3
6
C2
H4 WH
CPS-UN4
7
OPEN
T
BK
X1
11
8
STOP
E2
WH
12
CLS
COAXIAL CABLE
L2
H3
X2
13
WH
CHASSIS
BK
L1
WH
11
COMMON
MAS
SLS
H2
YE
24VAC
24VAC
BK
BR
L1
L1_BRK
H1 BK
X4
X3
14
L1 L2 L3
2
14
POWER
POWER
(SEE NOTE 1)
2A
BL
24VAC
24VAC
L1_MOT
INTERLOCK
BL
208/230V MOTOR WIRING
2
SBC
SBC
1
WH
L2
WH
WH
5
6
BL
WH
BL
RD
BR
WH
J
T6
WH
OR
GY
YE
3
A1
R3
R1
3
1
A2
4
R4
2
R2
A2
4
CHASSIS
NO
NC
SLS
YE
40VDC+
40VDC-
PU
RPM Sensor
WH
YE
T3
T9
T6
J
J
PU
1
BR
GY
BR
2
YE
3
J
J
RD
CLS
GN
T5
(SEE NOTE 1)
L1_MOT
T4
T8
575V MOTOR WIRING
YE
3 PHASE BR
Motor
T7
T2
WH
COM
(SEE NOTE 1)
BR
T1
R1 (GND)
PWR
GND
GND
RPM
GY
R3 (32 Vdc)
R2 (RADIO)
YE
RD
WH
Contactor
B
RD
BR
YE
PU
BR
GY
BR
YE
OR
GY
YE
GY
L1_BRK
COM
NC
NO
PU
L1_K3
NC
NO
COM
OLS
WH
NOTE 1: For motors that do not have pilot duty thermal protection and do not have the 2 motor brown wires, brown harness wires should be connected together.
NOTE 2: Connect blue wire directly from transformer to circuit board when no interlock switch is required.
MAS - Maintenance Alert System Error Codes
MAS LED
1 Blink
2 Blinks
3 Blinks
4 Blinks
5 Blinks
6 Blinks
7 Blinks
8 Blinks
01-35672C
J
T5
460V MOTOR WIRING
BL
A1
R3
T9
RELAY D
Contactor
A
R4
T3
T4
(SEE NOTE 1)
1
YE
3
PU
R1
T8
2
GY
1
T7
T2
5
6
3
WH
R1
T1
BR
GY
BR
L3
RELAY C
2
PU
(SEE NOTE 1)
FIELD WIRING BY INSTALLER
© 2011, The Chamberlain Group, Inc.
All Rights Reserved
DESCRIPTION
MAS triggered (cycles or months)
No RPM input during movement
MRT timed out
Obstruction sensed on closing
Stuck key - button pressed > 2 min.
Invalid option card plugged into
option card receptacles
Fail-safe device failed/not connected
Brownout detected