Brochure
 mm Reliable in Quality
TES-3600 3 phase Power Analyzer
(1P2W, 1P3W, 3P3W2M, 3P3W3M a. 3P4W)
M4 Current Clamp Probes
№ True RMS Sensing
Mm Datalogger (512 KB Memory, 20,000 Readings)
Hl Displays 10 Readings at the same time
H Software to view Real Time Waveform
E RS-232 interface / software us
KW, KVAR, KVA, pr,
KWh, KVARh 8: KVAh
Ti
IES 3 600 Power Analyzer
ACTIVE POWER PF~0 Hz ~ ls
[uN ET @
o,f e
a Ann. HAA,
ve Wh 123
APPARENT
POWER
—U3:V
—U3:A
REACTIVE | avr À “000!
DATA MA) — ©
Se elt me E a
TIME U12Y-M U23D- ho U31 m-s__
"Tm BEA, BELO, BERE
Ut: A ro В ВЕНА | Ea EEE
600V 250A 500A 1000A
oy и
Вей Чаи | Зику Sid | Dogs | Sendo [O
hal At a ds FEA и РТР, | uu РТА РАО
= bad I e ANE di) his e e e dl
1. Power Measurement
Active Power Measurement (KW)
Reactive Power Measurement (KVAR)
Apparent Power Measurement (KVA)
Power Integration Measurement
Power Factor Measurement
2. Datalogging Capacity
Manual data memory including each 3 sets V, |, P,
Q, S, PF, £c and Hz data Store to memory, total 99
sets data display on LCD for recorder.
3. Carrying Case Package :
TES 3600 3P4W POWER ANALYZER
FEATURES :
mM 10 Display Easy-to-View LCD Screen.
u Connectors for 4 Current Sensing Clamps.
E 1P2W, 1P3W, 3P3W2M E 3P4W Power Measurement.
mM True RMS Sensing.
E Power KW, KVAR, KVA, PF, Ес, Hz, &
Energy KWh, KVARh & KVAh Measurement.
mM Backlight display.
mM Manual Data Memory and Read (99 sets).
mM Data Logging (512KB Memory, 20,000 sets)
E Programmable Trigger - Points and Start / Stop Time.
mM RS-232 Optical Interface with three phase voltage /
current Waveform display and Harmonic analysis.
M Easy - to - use Push - Button Operation.
m Light Weight, Portable Design
ELECTRICAL SPECIFICATIONS (23°C+5°C)
Nu Voltage Measurement (V) :
Ranges | Method Accuracy _ Input Ranges Accuracy
impedance Determined by the voltage x | +0.5%rdg+10dgts+clamp on
600.0V | True RMS | +0.5%rdg+10dgts (>30V) 2MQ current range combination | sensor specification
E Current Measurement (A) : E Power Integration Measuremen :
Ranges Method Accuracy Power Integration | Resolution Accuracy
250A 0.0KWh to 9999MWh 0.1KWh +0.5%rdg+10dgts+clamp
‚5% 1 1
500A True RMS >on etd 0.0Kvarh to 9999Mvarh | 0.1Kvarh on sensor specifications
1000A 0.0KVAh to 9999MVAh | 0.1KYAh
E Active Power Measurement (KW) : E Power Factor Measuremen :
Ranges Accuracy Effect of Ranges Accuracy Polarity display
power factor -1.000(lead) to +1dgt for each When the current
Determined by the 0.000 to + 1.000 | calculation from lags the voltage
voltage x current ео +0.1%rd (lag) measured values | unsigned ; when the
range combination E current leads the
voltage : "-".
mM Reactive Power Measurement (KVAR) : u Frequency Measuremen :
Ranges Accuracy Effect of Ranges Measurement source Accuracy
power factor 40Hz to 100Hz Voltage Ul +0.5%rdg+1dgt
Determined by the
voltage x current AUS rege clamp +0.1%rd
.__.. _ |on sensor specification
range combination
EH Apparent Power Measurement (KVA) :
Size
GENERAL SPECIFICATIONS :
235(L)x116(W)x54(H)mm (9.3"Lx4.6"Wx2.1"H)
Operating Temperature and Humidity
0°C to 50°C (32°F to 122°F) R.H. < 80% non-condensing
Storage Temperature and Humidity
-10°C to 60°C (14°F to 140°F) R.H. < 70% non-condensing
Accessories
® Instruction manual
@ Deluxe carrying case
(1000A AC, jaw opening 40mm)
@ Softwar CD rom / Optical RS-232 interface
O Battery ( "AA" 1.5V x 8pcs )
® AC adaptor (110V-->12V ; 220V-->12V)
® 4pcs current clamp transducer (1, 2, 3, 4 cable length 3 meters)
@ 4pcs crocodiles test leads (blue, yellow, red, black, wire length 3 meters)
TES ELECTRICAL ELECTRONIC CORP.
7F, No.31 Lane 513, Rui Guang Rd., Neihu Dist, Taipei , Taiwan
Tel : (02) 2799-3660 Fax : 886-2-2799-5099
E-mail : tes@ms9.hinet.net
http://www.tes.com.tw