Ventis™ MX4 and MX6 iBrid™ for Mining - Air

Ventis™ MX4 and MX6 iBrid™ for Mining - Air
Ventis™ MX4 and MX6 iBrid™ for Mining
The most reliable
gas monitors for all
of your gas detection
needs within the mine:
■ Personal monitoring
■ Mine rescue
■ Emergency shelters
■ Diesel emissions
■ Seal monitoring
www.indsci.com
Common Configurations
■ Detect from one to four gases with
a wide range of sensor options
■ Gain increased instrument visibility
with a safety orange overmold
■ Realize true portability with multigas protection in single-gas size
■ Use the extended range battery
for up to 20 hours (without pump)
Part No.
Accessories
Part No.
18108630-0BC
18108631-AB
18108630-0BC
DS2 Docking Station*
18107664-ABC
18108191
18108209
18108650-A
18108950
18108175
18108183
18108813
18108814
18108631-00
V·Cal
18108815
18107664-600 V·Cal 6-Unit
Description
VTS-M1031001301 O2,CO,CH4
VTS-M1431001301 O2,CO,CH4,NO2
VTS-M1231001301 O2,CO,CH4,H2S
The part numbers listed above assume the instrument has a Safety Orange overmold, is
without a pump and has a 12-hour battery. To build your own Ventis, visit
www.indsci.com/ventisbuilder.
18108816
17134461
17134479
17134487
17134495
17134503
17143595
17148313-2
Description
DS2 Docking Station™ for Ventis MX4
B = Quantity of iGas® Reader: 0 = None
1 = 1 iGas Reader
2 = 2 iGas Readers
3 = 3 iGas Readers
C = Power Cord: 0 = US, 1 = UK, 2 = EU, 3 = AUS, 4 = ITA,
5 = DEN, 6 = SWZ
V•Cal™ Calibration Station
A = Instrument Type: 0 = Ventis, 1 = Ventis™ with pump
B = Power Cord: 0 = US, 1 = UK, 2 = EU, 3 = AUS, 4 = ITA, 5 = DEN,
6 = SWZ
V•Cal™ 6-Unit Calibration Station
AB = Number of Ventis (A) and Ventis with pump (B) Instruments
06 = 0 Ventis and 6 Ventis with pump
33 = 3 Ventis and 3 Ventis with pump
60 = 6 Ventis and 0 Ventis with pump
C = Power Cord: 0 = Universal with US, UK, EU, AUS Plug Adapters
Single-Unit Charger
Single-Unit Charger/Datalink
6-Unit Charger – A = Power Cord: 0 = US, 1 = UK,
2 = EU, 3 = AUS, 4 = ITA, 5 = DEN, 6 = SWZ
MX4 External Battery Charge Adaptor
Ventis without pump, Soft Carrying Case, Li-ion Battery
Ventis without pump, Soft Carrying Case, Extended Range Li-ion
Battery or Alkaline
Ventis without pump, Hard Carrying Case with display, Li-ion Battery
Ventis without pump, Hard Carrying Case with display,
Extended Range Li-ion Battery or Alkaline
Ventis, without pump, Hard Carrying Case without display, Li-ion
Battery
Ventis without pump, Hard Carrying Case without display, Extended
Range Li-ion Battery or Alkaline
Replacement Sensor, Oxygen (O2)
Replacement Sensor, Hydrogen Sulfide (H2S)
Replacement Sensor, Carbon Monoxide (CO)
Replacement Sensor, Combustible Gas (LEL/CH4)
Replacement Sensor, Nitrogen Dioxide (NO2)
Replacement Sensor, Sulfur Dioxide (SO2)
Replacement Extended Range Li-ion Battery Pack, MSHA
18108650-0
6-Unit Charger
18108191 Ventis
Charger
Common Configurations
Description
MX6-M103N511
■ Detect from one to six gases
MX6-M4H3N401
O2,CO-HI RANGE, CH4-IR, CH4,NO2, used for mine rescue teams
MX6-M103Q511
O2,CH4,CO2, CO, with pump used for emergency shelters
■ Plug-and-play field replaceable
sensors
MX6-M1B36401
O2,CO,CH4,NH3,HCN, used for various metal non-metal applications
MX6-M1234501
O2,CO,CH4,H2S,NO2, used when all three toxic gases are present
■ Available with or without internal
sampling pump
■ Rugged, concussion-proof overmold
SP6 Motorized
Sampling Pump
18106724-ABC+ DS2
Docking Station
18107136 Multi-Unit Charger
18106971 Charger
*NOTE: Monitor is not
included with accessories
Part No.
■ Simple, user-friendly,
menu-driven navigation
www.indsci.com
O2,CO,CH4-IR, CH4, with pump used for seal monitoring
Accessories
Part No.
18106724-0BC
18106765
18107086
18106971
18107094
18107011
18107136
17131038-4
17131038-5
17131046-6
18106856-0
18106856-1
18106880-0
18106880-1
18106831
18106864
17124975-3
17124975-2
17124975-1
17124975-M
17124975-4
17124975-5
17124975-6
17124975-N
17124975-Q
17124975-B
Description
DS2 Docking Station for MX6
B = Quantity of iGas® Reader: 0 = None
1 = 1 iGas Reader
2 = 2 iGas Readers
3 = 3 iGas Readers
C = Power Cord: 0 = US, 1 = UK, 2 = EU, 3 = AUS, 4 = ITA,
5 = DEN, 6 = SWZ
SP6 Motorized Sampling Pump Module
MX6 Datalink Assembly – Software included
MX6 Replacement Battery Charger
MX6 Battery Charger/Datalink, Universal
MX6 Battery Charger, 12V
MX6 Battery Charger, 5-Unit
Rechargeable Li-ion Battery Pack, MSHA/AUS
Rechargeable Li-ion Ext. Battery Pack, MSHA/AUS
Alkaline Battery Pack, MSHA/AUS
MX6 without pump Hard Leather Carrying Case
MX6 without pump Hard Leather Case and without display
MX6 with pump Hard Leather Carrying Case
MX6 with pump Hard Leather Case without display
Nylon Carrying Case supplied with MX6 without pump
Nylon Carrying Case, supplied with MX6 with pump
Replacement Sensor, Oxygen (O2)
Replacement Sensor, Hydrogen Sulfide (H2S)
Replacement Sensor, Carbon Monoxide (CO)
Replacement Sensor, Combustible Gas (CH4)
Replacement Sensor, Nitrogen Dioxide (NO2)
Replacement Sensor, Sulfur Dioxide (SO2)
Replacement Sensor, Ammonia (NH3)
Replacement Sensor, Methane (IR) (CH4-IR)
Replacement Sensor, Carbon Dioxide (IR) (CO2-IR)
Replacement Sensor, Hydrogen Cyanide (HCN)
Ventis MX4 Specifications*
MX6 iBrid Specifications*
Instrument Warranty:
Two- year warranty, including sensors and battery pack
Instrument Warranty:
Warranted for as long as the instrument is supported by Industrial Scientific Corporation
Case Material:
Polycarbonate with protective rubber overmold
Case Material:
Lexan/ABS/Stainless Steel with protective rubber overmold
Dimensions:
103 mm x 58 mm x 30 mm (4.1” x 2.3” x 1.2”) - Lithium-ion battery version
Weight:
182 g (6.4 oz) - Lithium-ion battery version
Display/Readout:
Backlit Liquid Crystal Display
Power Source/Run Time:
Rechargeable Lithium-ion Battery Pack (12 hours* @ 20ºC)
Rechargeable Extended-Range Lithium-ion Battery Pack (20 hours* @ 20ºC)
Replaceable AAA Alkaline Battery Pack (8 hours* @ 20ºC)
Alarms:
Ultra-bright LEDs, audible alarm (95 dB at 30 cm) and vibrating alarm
Sensors:
Combustible gases/methane - Catalytic Diffusion
O2, CO, H2S, NO2, SO2 - Electrochemical
Operating Temperature Range:
-20°C- 50°C (-4°F-122°F)
Operating Humidity Range:
15%-95% Non-condensing (continuous)
Measuring Ranges:
Combustible Gases:
Methane (CH4): Oxygen (O2): Carbon Monoxide (CO): Hydrogen Sulfide (H2S): Nitrogen Dioxide (NO2): Sulfur Dioxide (SO2): 0-100% LEL in 1% increments
0-5% of vol. in 0.01% increments
0-30% of vol. in 0.1% increments
0-1,000 ppm in 1 ppm increments
0-500 ppm in 0.1 ppm increments
0-150 ppm in 0.1 ppm increments
0-150 ppm in 0.1 ppm increments
Certifications:
MSHA: 30 CFR Part 22; Permissible for Underground Mines;
Lithium-ion versions without pump only
CSA:
UL: Class I, Division 1, Groups A B C D, T4; Ex d ia IIC T4
C22.2 No. 152 for %LEL reading only
Class I, Division 1, Groups A B C D, T4; Zone 0, AEx ia IIC T4
Class II, Groups F G (Carbonaceous & Grain Dust); IP66; IP67
* These specifications are based on performance averages and may vary by
instrument
Dimensions:
135 mm x 77 mm x 43 mm (5.3" x 3.05" x 1.7") – without pump
Weight:
409 g (14.4 oz) – without pump
Display/Readout:
Color Graphic Liquid Crystal Display
Power Source/Run Times:
Rechargeable Lithium-ion (Li-ion) Battery Pack (24 hours*)
Rechargeable, Extended-Range Lithium-ion (Li-ion) Battery Pack (36 hours*)
Replaceable AA Alkaline Battery Pack (10.5 hours*)
Operating Temperature Range:
-20ºC to 55ºC (-4ºF to 131ºF)
Operating Humidity Range:
15% to 95% non-condensing (continuous)
Sensors:
Combustible Gas / Methane – Catalytic Diffusion/Infrared
Oxygen and Toxic Gases – Electrochemical
Carbon Dioxide – Infrared
Measuring Ranges:
Combustible Gas – 0 to 100% LEL in 1% or 10 ppm increments – Catalytic
(0 to 100% LEL in 1% increments – Infrared)
Methane – 0 to 5% of volume in 0.01% increments – Catalytic
(0 to 100% of volume in 1% increments – Infrared)
Oxygen – 0 to 30% of volume in 0.1% increments
Carbon Monoxide – 0 to 1,500 ppm in 1 ppm increments
(0 to 9,999 ppm in 1 ppm increments optional)
Hydrogen Sulfide – 0 to 500 ppm in 0.1 ppm increments
CO/H2S – Carbon Monoxide – 0 to 1,500 ppm in 1 ppm increments
– Hydrogen Sulfide – 0 to 500 ppm in 0.1 ppm increments
Hydrogen – 0 to 2,000 ppm in 1 ppm increments
Nitrogen Dioxide, Sulfur Dioxide – 0 to 150 ppm in 0.1 ppm increments
Hydrogen Cyanide, Hydrogen Chloride –
0 to 30 ppm in 0.1 ppm increments
Carbon Dioxide – 0 to 5% of volume in 0.01% increments
Certifications:
MSHA : 30 CFR Part 22; Permissible for Underground Mines
CSA:
Class I, Groups A,B,C,D T4; Ex d ia IIC T4
UL: Class I, Groups A,B,C,D T4; Class II, Groups F,G; AEx ia d IIC T4
* These specifications are based on performance averages and may vary by
instrument
Mine Rescue Dog Uses
MX6 iBrid™ Personal Gas Monitor
Ginny, a Dutch Shepherd, has been trained to support
mine rescue teams in locating injured and trapped miners.
She assists Alpha Natural Resources in coal mine search
and rescue using her vast skill set acquired through
intensive training, as well as her developed sense of smell.
To ensure Ginny’s safety, she wears an MX6 iBrid from
Industrial Scientific to detect hazardous gases within the
mine. Learn more at www.AlphaMineRescueDog.com.
Distributed by:
Air-Met Scientific Pty Ltd
Work with Confidence
Air-Met Sales/Service
P: 1800 000 744
F: 1800 000 774
E: sales@airmet.com.au
Air-Met Rental
P: 1300 137 067
E: hire@airmet.com.au
W: www.airmet.com.au
V-MX6-MINE_EN_0812 © 2012 Industrial Scientific Corporation
1-800-338-3287
www.indsci.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising