Quick Start Guide - i3 International

Quick Start Guide - i3 International
Quick Start Guide
1.3MP Door Count Covert IP Camera
Ax48DC2/Ax48DC3
33.5 mm (1.32”)
78 mm (3”)
When installing your Ax48DC camera be sure to avoid:
• excessive heat, such as direct sunlight or heating appliances
• contaminants such as dust and smoke
• strong magnetic fields and areas with mechanical vibrations
• moisture and humidity
• fluorescent lamps or objects that reflect light and unstable light sources
• temperatures below -30° C (-22° F) and above 60° C (140° F).
CAMERA PARTS AND DEFINITIONS
5
2 3 4
6
15
VIN1
AUDIO
IN
AUDIO
OUT
7
SD
POWER SUPPLY
Input voltage must comply with the SELV (Safety Extra Low Voltage) and the Limited
Power Source with 12 VDC according to the IEC60950-1 standard.
Ax48DC camera series does not support direct PoE power. Use a PoE splitter to
connect the camera to the PoE switch.
14
For maximum optical clarity, the camera lens must remain clean. Use a soft, dry cloth
to remove finger prints or dust from the dome cover.
Use a blower to remove dust from the lens.
Do not use volatile solvents such as alcohol, benzene, or thinners, as they may
damage the surface finishes.
•
•
9
8
LAN(PoE)
RXD TXD GND IN1 1B 1A
DC 12V
RESET
RS232
•
SERVICING
•
To avoid electrical shock and to preserve the product warranty, DO NOT disassemble
the camera. Refer servicing to qualified personnel only.
To reduce the risk of fire or electric shock, do not expose the product to rain or
moisture.
If the system needs to be modified or repaired, contact a certified i3 International
Dealer/Installer. When serviced by unauthorized technician, the system warranty will
be voided. Should you have any problems or questions regarding our products, contact
your local i3 International Dealer/Installer.
•
•
16
1
CLEANING
ALARM
•
30.68 mm (1.2”)
31.53 mm (1¼”)
SAFETY
31.53 mm (1¼”)
107.57 mm (4 ¼”)
105.06 mm (4.14”)
Camera’s default IP address is 192.168.1.64
Camera’s default Subnet mask address is 255.255.255.0
Default camera User Name: i3admin and default Password: i3admin
•
48.68 mm (1 15/16”)
95 m
m
Thank you for purchasing an i3 Ax48DC-series Door Count Covert IP Camera.
Ax48DC comes in two models:
• Ax48DC2 (2.1mm lens, suitable for low ceiling installations 8-10 meters AFF) and
• Ax48DC3 (2.8mm lens, suitable for high ceiling installations 10-14 meters AFF).
CAMERA DIMENSIONS
(3 ¾”)
Please read this guide carefully before you install the camera. Keep this guide
for future reference
UNPACKING
1
8
3
4
5
2
1. Ax48DC, Main Unit w/ attached
mounting plate
2. Wall Mounting Bracket
3. Round-head screw (Tapping Type) x3
4. Plastic anchor x3
i3-TRNG-CAMS-Ax48DC-QSG.indd
6
5.
6.
7.
8.
9.
7
9
Adhesive strip
Camera with RJ12 cable
Dome cover (Optional)
PoE Gigabit Splitter
PoE Gigabit Splitter Power Cable
12
13
10 11
19
17
18
No. Description
1
Camera’s Main Unit w/ with attached mounting plate. If your camera comes
with mounting plate not attached to the main unit, use a small Phillips
screwdriver to secure the plate to the main unit with four small black screws
(provided).
2
Power Indicator LED. Solid Red = Power ON, Unlit = Power OFF
3
Status Indicator LED. Solid Green = Camera operating correctly.
Unlit = Camera is not operating normally.
4
Link Indicator LED. Flashing Amber = Network connection is operating correctly. Unlit = No network connection.
5
Audio Interface
6
RJ12 Port. Connect the camera cable to this port.
7
Micro SD Card Slot (64GB max)
8
RESET Button.
9
RS-232 & Alarm Interface
Rev. 160826
QUICK START GUIDE
Ax48DC Covert IP Camera
CONNECT CAMERA TO i3 SRX-PRO SERVER
No. Description
Camera’s default IP: 192.168.1.64. Default Login / PW: i3admin / i3admin
10
DC 12V Power Input. Connect the PoE Gigabit Splitter power cable.
11
LAN Port. Connect one end of the second CAT5/6 cable (not supplied) to
DATA(OUT) RJ45 port on the Splitter and the other end to the LAN RJ45 port
on the Main Unit.
12
Mounting plate, attached to the Main Unit. If your camera comes with mounting plate not attached to the main unit, use a small Phillips screwdriver to
secure the plate to the main unit with four small black screws (provided).
13
Wall Mounting Bracket (Attach to the wall, then slide into the mounting plate
on the main unit)
14
Camera with RJ12 cable. Connect to the VIN1 port on the Main Unit.
Use the adhesive strip provided to attach the camera to the wall (optional).
15
Dome cover (Optional). Fit over the camera, if using.
16
PoE Gigabit Splitter. POWER+DATA (IN) port.
Connect one end of the first CAT5/6 cable (not supplied) to the POWER+DATA
(IN) RJ45 port on the Splitter and the other end to the Gigabit switch.
17
PoE Gigabit Splitter. Output Power (12V) port. Connect the green terminal end
of the Power Cable (#19) to the Output Power (12V) port.
18
PoE Gigabit Splitter. DATA(OUT) RJ45
Connect one end of the second CAT5/6 cable (not supplied) to DATA(OUT)
RJ45 port and the other end to the LAN RJ45 port on the Main Unit (#11).
19
PoE Gigabit Splitter Power Cable.
Connect the green terminal end of the to the Output Power (12V) port on the
Splitter (#17). Connect the other end of the Power Cable to the DC 12V port on
the Main Unit (#10).
Change Camera’s Default IP
1. Close SRX-Pro Server software by pressing Alt+Shift+Ctrl+F4.
2. Write down the IP address of the onboard NIC (LAN) (or of NIC1 if your SRX-Pro
Server has two onboard NIC cards).
3. Connect your camera to i3 Server (see Camera Network Infrastructure diagram).
4. Turn on your Annexxus 48DC camera.
5. Launch the CD that came with your Annexxus camera and double-click
“AnnexxusConfigurationTool.msi” file to install Annexxus Configuration Tool
(ACT) application. ACT application discovers all Annexxus cameras connected to
your network.
6. Follow the ACT installation instructions until the application has been successfully
installed on your SRX-Pro Server.
7. Double-click i3 Annexxus Configuration Tool icon on the Desktop to launch
the ACT application. Accept the ACT license agreement.
8. ANNEXXUS Configuration Tool window will display a list of active network
cameras.
CAMERA INSTALLATION
• Depending on the type of installation, additional mounting accessories may need to be
purchased.
• It is the installer’s responsibility to ensure that the mounting surface is suitable for the
chosen installation method.
• Based on installation location and surface type, supplied screws and anchors may not
be adequate. Mounting hardware is site-specific and may need to be supplied by the
installer.
• The camera can be used on its own for covert installations or with the dome cover for
ceiling door count installations.
• Follow Camera network infrastructure diagram below as a general installation guideline.
9. Select the desired Annexxus camera in the list (left-click).
10. In the Device(s) Communication area, enter the new IP Range (address) and
Subnet Mask of the camera. The new camera IP address must match the IP range
of your SRX-Pro LAN or NIC1 card (see Step 2).
E.g. If your SRX-Pro Server’s IP address is 192.138.10.122, change your Annexxus
camera’s IP address to 192.138.10.XXX. Remember: Annexxus Cameras cannot
share an IP address, each camera requires its own unique IP address.
CAMERA NETWORK INFRASTRUCTURE
Ax48DC2/Ax48DC3 Camera
Door Count
Ax48DC2/Ax48DC3
Camera
Covert Surveillance
Ax48DC2 (2.1mm lens, low ceiling install: 8-10 m (26-32 ft) AFF);
Ax48DC3 (2.8mm lens, high ceiling install: 10-14 m (32-46ft) AFF)
8m (26ft) RJ12,
provided)
8m (26ft) RJ12,
provided)
i3 Server (VMS)
Ax48DC2/Ax48DC3
Main Unit
12V DC
Network RJ45
Ax48DC2/Ax48DC3
Main Unit
POE Splitter
(SP12)
12V DC
POE Splitter
(SP12)
Network
RJ45
POE Switch
Network
RJ45
Please Note: Scan the QR code to the right or visit www.i3international.com to view and download the full User Manual for this
camera. Also available for download is the AnnexxusConfigurationTool or ACT program used to locate and configure your
cameras with your SRX-Pro software. This program is already installed in SRX-Pro v3.3.3.69 and higher. Please contact our
Technical Support team if you have any questions or concerns regarding camera installation or you require software services or
support. Technical support can be reached by email at:
support@i3International.com or by phone toll free 1.877.877.7241.
Network RJ45
QR Code to
Complete
User Manual
/ ACT
Page -2-
Rev. 160826
QUICK START GUIDE
11. Make sure the Default Account checkbox is checked off.
12. Click Update. Then click Yes in the confirmation window.
Ax48DC Covert IP Camera
Add Ax48DC to SRX-Pro Server
1. Make sure that the latest version of GiPi updater is installed on your SRX-Pro
Server. Once the latest GiPi updater has been installed, restart i3 SRX-Pro Server.
Please go to www.i3international.com/software-downloads to download the most
recent GiPi.
2. Log In and go to the Setup -> IP Camera tab.
3. Click the Search button to display connected Annexxus cameras on the network.
4. Select the desired detected camera in the list and click Select.
13. Wait a few moments for a successful confirmation message.
14. Repeat Steps 9-13 for all detected Annexxus cameras in the ACT application OR
Select multiple cameras (Ctrl + left-click) and enter IP range to assign IP addresses
sequentially to the selected cameras.
View Camera in IE browser
1. Once the IP address of the Annexxus camera(s) has been changed, make sure you can
connect to the camera(s) through Internet Explorer:
2. Launch Internet Explorer by double-clicking the IE
icon next to the desired camera in the ACT.
The password window will be displayed.
3. Enter the default camera User Name: i3admin and
default Password: i3admin
4. The camera will suggest that a stronger
password be entered. Click OK in the popup message window to enter a stronger
password or click Cancel to keep the
default password and see Live video.
5. (Optional) If you have chosen to enhance
your camera’s password by clicking OK, the camera’s User setup page will be opened
automatically. In the User tab, select i3admin user, then click Modify. Enter a more
secure password in the Password and Confirm fields following the password
requirement guidelines shown on the screen. Click OK when done. Make sure to keep
a record of your new password. Click Cancel to close Modify User window to close it.
5. In the Select IP Camera window, enter your User Name and Password if you
have changed your camera’s default password. If the camera’s credentials are still
i3admin / i3admin, leave User Account fields blank. Click Add.
6. The selected camera will be added to the IP Camera list and the live video image
from the camera will be shown in the Preview window.
6. (Recommended) i3 recommends disabling Illegal Login feature on the first login.
Go to Configuration > Security > Security Service tab.
Uncheck the Enable Illegal Login Lock checkbox and click Save.
7. Click Live View.
8. Click Allow in the browser add-on message at the bottom of the screen.
9. Click on the plug-in download message inside the Live View screen .
7. Assign the IP camera to the SRX-Pro video channel in the Ch. In. column.
10. Click Run or Save in the download confirmation message at the bottom of the screen.
11. Launch the downloaded WebComponents.exe file and follow the installation
instructions. Click Finish to close the final installation screen.
12. The camera’s live video stream will now be seen in the Live View screen.
13. If you do not see the camera live video stream on the screen,
call i3 International tech support for troubleshooting tips:
1.877.877.7241
8. Your Annexxus camera is now connected to SRX-Pro Server and is ready to record.
You may change resolution and frame rate for the Annexxus camera in the
IP Camera tab menu or you may choose to configure the camera’s advanced
settings through the IE browser.
Page -3-
Rev. 160826
QUICK START GUIDE
Specifications
Ax48DC Covert IP Camera
Ax48DC2
Ax48DC3
Image System
Image Sensor
1/3’’ Progressive Scan CMOS
Signal System
NTSC/PAL
Optical System
Focal Length (built-in lens)
2.1mm
2.8mm
F-stop Range (F-number)
F2.2
F2.0
Horizontal FOV (Field of View)
115º
92.5º
RJ12 Lens Cable Length
8 m (26 ft)
Day/Night
ICR
Electric
Digital Noise Reduction (DNR)
3D Digital Noise Reduction
Wide Dynamic Range (WDR)
Min. Illumination
120dB Wide Dynamic Range
Color: 0.01 Lux @ (F1.2, AGC ON), 0.028 Lux @ (F2.0, AGC ON)
B/W: 0.001 Lux @ (F1.2, AGC ON), 0.0028 Lux @ (F2.0, AGC ON)
White Balance
MWB, AWB1, AWB2, Locked WB, Fluorescent WB, Incandescent Lamp, Warm Light Lamp, Natural Light
Shutter Speed
1/30s (1/25s) to 1/100,000s
Image Enhancements
Adjustable via Web Browser
Rotate/Mirror, Saturation, Brightness, Contrast, Sharpness, Digital Defog, EIS (Electrical Image Stabilizer),
Privacy Mask
Day/Night Mode
Day/Night/Auto/Scheduled/Triggered by Alarm Input
Other
Reset, Flickerless, Heartbeat, Password protection, Watermark
Network Specifications
Video Streaming Compression Method
Triple Streaming. H.264 / MJPEG / MPEG4
H.264 Type
Baseline Profile / Main Profile / High Profile
Video Bit Rate
32 Kbps – 16 Mbps
Maximum Resolution & Frame Rate
Network Protocols
Main Stream / Third Stream: NTSC: 30fps @ 1280 x 960; PAL: 25fps @ 1280 x 960
Sub Stream: NTSC: 30fps @ 704 x 480 (4CIF); PAL: 25fps @ 704 x 480 (4CIF)
TCP / IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, PPPoE, NTP, UPnP, SMTP, SNMP,
IGMP, 8-2.1x, QoS, IPv6, Bonjour
Mechanism
Communication Interface
1 x RJ45 10M / 100M Ethernet Interface / 1 x RS232 / 1 x RS485
Audio Interface
1 x 3.5mm audio input (Mic in / Line in) output external interface
Alarm I/O
1/1
Dimensions (Main Unit)
Dimensions (Camera)
107.57mm x 78mm x 33.5mm (4¼” x 3” x 1.32”)
48.68mm x 30.68mm x 31.53mm (1.92” x 1.2” x 1¼”)
Dimensions (Camera dome cover)
Ø 95mm x 31.53mm (3¾” 1¼”)
Weight
approx. 770g (1.7lb) w/ RJ12 cable
Regulations, Ratings
ONVIF, PSIA
Power Supply
Power Supply
12 V DC ± 10%
Power Consumption
Max. 6.5W
Environment
Operating Temperature
-30° C - 60° C (-22° F - 140° F)
Operating Humidity
95% or less (non-condensing)
Warranty
Standard Warranty
i3 Superior 3 year warranty
i3 INTERNATIONAL INC.
1.866.840.0004
www.i3international.com
U.S.A.
4450 Witmer Industrial Estates Unit 4
Niagara Falls, NY 14305
Canada 780 Birchmount Road, Unit 16,
Scarborough, ON, M1K 5H4 
Was this manual useful for you? yes no