SR Series - Petro Industrial
2014
SR Series
Inverter Residential Air Conditioners
MHIAA is proudly sponsoring
Monika’s Doggie Rescue
2
SR Series.
Inverter Residential Air Conditioners.
The ideal solution
for air conditioning
SR series Air Conditioners 2014
WELCOME
Equipped with an easy to use controller boasting an
assortment of convenient functions and filters, compact
stylish design and quiet operation, a Mitsubishi Heavy
Industries air conditioner will be a valuable addition to any
home. You can rest assured that your family will enjoy the
luxury of air conditioned comfort all year round.
The SR range includes capacities from as low as 2.0kW to
as high as 9.2kW which means you can air condition the
smallest bedrooms to the largest entertainment areas. Priding
itself on the reliability of its air conditioners and, with offices
across Australia and New Zealand and an extensive network
of service agents, Mitsubishi Heavy Industries will keep your
air conditioner working perfectly over the years.
High Performance Air-Conditioning
3
4
DRED.
DRED enabled (complies to AS/NZS4755)
The new RAC model range include a Demand Response Enabling Device
(DRED) built into each indoor unit in the ZMA/ZMXA range.
A unit installed with a DRED device allows you to participate in incentive
programs applicable to your region, such as the ENERGEX QLD Positive
Payback Program.
Anti-microbial specifications and design will deliver cleanliness and safety
Anti-microbial indoor fan
The indoor fan has undergone anti-microbial treatment to resist
growth of mould and germs. Mould creating odours which can
occur when an air conditioner is not in operation are prevented.
·Intestinal bacteria (Escherichia coli IFO 3972)
·Staphylococcus aureus subsp. aureus IFO 12732
Testing Authority: Japan Food Analysis Center
Test Results Issued: 2004-4-7.
Test Report No.: 104034022-001
Tests were conducted with reference to the antimicrobial strength tests in JIS Z 2801
2000 “Antimicrobial Products-Antimicrobial Test Method” –5.2 Antimicrobial Effects:
Test Methods for Plastic Products, etc.
·Apergillus niger IFO 6341
Testing Authority: Japan Food Analysis Center
Test Results Issued: 2004-4-23.
Test Report No.: 104034022-002
Tests were conducted with reference to the antimicrobial strength tests in JIS Z 2801
2000 “Antimicrobial Products-Antimicrobial Test Method” –5.2 Antimicrobial Effects:
Test Methods for Plastic Products, etc.
SR series Air Conditioners 2014
Comparison of growth of bacteria and mold on fan surfaces
(microscopic image)
without
with
Anti-microbial Anti-microbial
without
with
Anti-microbial Anti-microbial
Aspergillus niger IFO 6341
Escherichia coli IFO 3972
In tests conducted at the Mitsubishi Heavy Industries Nagoya Research Lab,
24 hrs after contact with bacteria, cultured on agar media.
Features.
FEATURES
Self Clean Operation
The ‘self clean operation’ is operated for
2 hours after the unit has ceased normal
operation. The indoor fan continues to
operate on ultra low speed to dry the unit.
This restricts the growth of mould. This
feature can be selected on the remote
control.
Allergen Clear System
The ‘Allergen Clear system’ suppresses the influence of the allergen caught by the filter by controlling
the temperature and humidity.
Catching Allergen
on the Filter
-15°C
Heating
Cooling Operation
To make condensing water.
+24°C
r everyday
ises in ou
life
21dB
ns
nversatio
Normal co
60dB
Cooling
To dry up the indoor unit
miliar no
on with fa
70dB
-15°C
Self-Clean Operation
To give moisture to the
Filter to inactivate allergen
Comparis
+46°C
AIR Purify
Heating Operation
e
Quiet offic
50dB
a
rary Late night in
ea
burban ar
typical su
In the lib
40dB
30dB
-20
-10
0
10
20
30
40
50
For the capacities under low temperature conditions,
refer to technical manual.
20dB
60dB
50dB
Heating and cooling operations are possible
at an outdoor temperature as low as –15°C.
Our advanced technology has improved the
heating and cooling operation range. Units
can be installed when heating or cooling
operations are required at low ambient
conditions down to -15°C.
30dB
21dB
SRK20ZMXA-S
0dB
Wide Operation Range
40dB
10dB
(In the Cooling Lo mode)
Quiet Operation
The secret of quiet operation.
The combination of the jet airflow system
and serration stabilizer configuration ensures
uniform breeze to every corner of the room. It
also makes it possible to lower the operation
noise further by minimizing the interaction
between airflow and the fan.
High Performance Air-Conditioning
5
6
Airflow.
3D AUTO Vertical + Horizontal AIR SCROLL.
3 motors make 3 independent controls
Programmed air distribution
3D AUTO is a one touch programme. Three motors (one vertical
working motor + two horizontal working motors) make three
independent air flow controls.
The airflow is uniform, quiet and reaches at long distance from the
indoor unit.
3D AUTO
Programmed 3D AUTO
Hi-Power (Quick)
Cool Shower
Manual Setting
Floor Heating
Vertical Swing
Swing
1
Wide Swing (Every Corner)
Swing
2
Horizontal Air Scroll 8 Direction Swing
Center (Long)
Swing
3
2
3
4
8
7
6
5
Swing
Wide-Air (Equal)
4
1
Cool Shower
Floor
Automatic control of air flow volume and air flow
direction enables comfortable air conditioning of the
entire room.
In cooling operation, cooled air flows directly to the
ceiling not directly onto the occupants of the room. The
comfort cooled air flow comes down from the ceiling like
a soft shower.
In heating operation, warm air flows to the floor directly
and spreads along the floor. The concentration of the
warm air at floor level increases comfort.
SR series Air Conditioners 2014
Swing
Spot
Wide
Individual control of right and left louver enables air
flow direction from the right and the left side of the
unit, setting the most preferable air flow direction and
determining whether direct air flow is required or not.
Applied models
SRK-ZJX, SRK-ZJ
SRK63/71/80ZK,
Manual Setting onl
Airflow.
Jet air scroll long reach & silent air flow.
Aircraft technology was used in the design of the air conditioner’s airflow system
FEATURES
We used the same aerodynamic analysis technology as used in
developing jet engines.
CFD (computational fluid dynamics) is used for
blade shape design and air channels for jet engines.
The same technology has been used in our air
conditioners. The airflow of the jets created in this
system enables a large volume of air to be blown with
a minimum amount of power consumption. The airflow
is uniform, quiet and reaches a long distance from the
indoor unit.
Fast
Slow
Colors in the figure show the air speed.
SRK50/60ZMXA
Long Reach Air Flow
The jet technology enables powerful airflow
ideal for large living areas and commercial
premises, increasing your comfort.
(in cooling operation)
SRK63/71/80/92ZMA
(in cooling operation)
powerful
15m
17m
Positioning of Installation
You can set the left-right air flow directions when you
install the air conditioner near the side wall by remote
controller operation.
New louver
80% increased
The new louver has a new design and shape.It has
increased in surface area by 80%. In addition to
improved control of the increased air flow volume, it
has improved controllability of the right to left swing
function.
previous
New
High Performance Air-Conditioning
7
8
Our Latest Technologies.
Applied to all inverter models.
New propeller fan
Silicon-coated PCB
The new propeller fan was
carefully matched with a fan
motor in order to keep the same
capacity as that of previous
models with less electrical
consumption. In synergy with
the leaf shape grill has seen an
improvement of energy efficiency
and a decrease of sound level.
(SRC50/60ZMXA-S)
The printed circuit board of the outdoor unit is
coated by silicon. The coating ensures longevity
of the board in humid conditions.
Energy saving leaf shape grill
The leaf shape grill was developed in order to
maximize natural air flow sent by the propeller
fan along the grill. The airflow is very smooth with
minimum air resistance. This has lead to a decreased
fan motor load and improvement of energy efficiency.
(SRC20~50ZMA-S)
SRC20~50ZMXA-S
High efficiency scroll
compressor. Low vibration
and low sound level
By using a scroll compressor there
has been an improvement of energy
efficiency. Lower vibration and lower
sound level have been achieved.
Further improvement to efficiency was
realized by use of a neodymium magnet
applied in the compressor motor.
(SRC50/60ZMXA-S)
Superior corrosion resistance
The base of the outdoor unit is hot dipped to
provide superior corrosion and scratch
resistance.
photo is composite image
Indoor unit
Outdoor unit
A combination of fin configuration and
copper tube has enabled maximum air
flow whille keeping the same size width
of the indoor unit.
Efficiency rate of heat exchanger has
been improved compared with previous
models. The new fin design allows
maximum air flow and saving energy.
Redesigned by changing the fin
configuration from flat sheet to new
M shape fin, efficiency has been
improved. An optimum balance of
heat transfer and air flow has been
achieved.
SR series Air Conditioners 2014
Inverter Heat Pump (High COP).
PRODUCTS
SRK-ZMXA-S
Wall mounted type
SRC20ZMXA-S • SRC25ZMXA-S
SRC35ZMXA-S
SRK20ZMXA-S • SRK25ZMXA-S • SRK35ZMXA-S • SRK50ZMXA-S • SRK60ZMXA-S
Single
Multi
SRC50ZMXA-S • SRC60ZMXA-S
Most SRK-ZMXA series can be selected for use
as indoor units in combination with the SCM Multi
system outdoor unit.
Refrigerant Pipe Length
Maximum Pipe Length
Refrigerant Pipe Length
15m
10m
Maximum Pipe Length
Maximum Height Different
SRK20ZMXA-S • SRK25ZMXA-S
• SRK35ZMXA-S
St
3HOT
Filter System Operation Filter
Keep
Convenience & Economy
Auto
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
Maintenance & Prevention
Economy
On Timer OFF Timer
24h Timer
SRK50ZMXA-S • SRK60ZMXA-S
Comfortable Air Flow
t Sp
ar
Allergen Self Clean Allergen
t
ur
FUNCTIONS
Comfortable
SUN
30m
20m
Maximum Height Different
Sleep
DRY
MC
Others
Self
Detachable
Diagnostic
Back-up
Auto
Switch Restart
Luminous
24h ION
Indoor
SRK20ZMXA-S
SRK25ZMXA-S
SRK35ZMXA-S
SRK50ZMXA-S
SRK60ZMXA-S
Outdoor
SRC20ZMXA-S
SRC25ZMXA-S
SRC35ZMXA-S
SRC50ZMXA-S
SRC60ZMXA-S
2.0 (0.9-3.1)
2.55 (0.9-3.2)
3.5 (0.9-4.1)
5.0 (1.1~5.8)
6.0 (1.1~6.8)
2.5 (0.9-4.3)
3.13 (0.9-4.7)
4.3 (0.9-5.1)
6.0 (0.6~7.7)
6.8 (0.6~8.2)
Heating H2
N/A
3.79
4.04
6.26
6.28
Cooling T1
0.35 (0.19-0.70)
0.49 (0.19-0.82)
0.845 (0.19-1.01)
1.30 (0.20~1.80)
1.86 (0.20~2.50)
0.45 (0.23-1.00)
0.595 (0.23-1.12)
0.96 (0.23-1.35)
1.36 (0.20~2.43)
1.67 (0.20~2.70)
6
5
3
3
1.5
5.5
5.5
3.5
4
3.5
Cooling T1
5.71
5.20
4.14
3.85
3.23
Heating H1
5.56
5.26
4.48
4.41
4.07
Heating H2
N/A
3.46
3.22
3.21
2.48
Cooling(Outdoor)
60
60
63
63
64
59
60
62
63
64
39-30-24-21
41-31-25-22
43-33-25-22
47-40-27-25
51-41-29-25
38-33-25-21
41-34-27-21
42-35-27-22
48-40-33-26
48-41-34-27
40
41
45
45
45
42
42
43
45
45
192-133-105-83
208-150-105-83
225-158-105-83
225-183-133-116
242-208-142-117
200-158-117-105
217-167-125-105
233-183-133-108
283-241-175-133
292-250-183-142
Power supply
1 Phase 220~240V 50Hz
Cooling T1
Capacity
Input
Energy Label
EER
COP
Sound power level (JIS C9612)
Sound pressure level (JIS C9612)
Silent Mode Sound Pressure level
Airflow
External dimensions (HXWXD)
Net weight
Heating H1
Heating H1
Cooling T1
Heating H1
Heating(Outdoor)
Cooling(Indoor)
Heating(Indoor)
Cooling(Outdoor)
Heating(Outdoor)
Cooling(Indoor)
Heating(Indoor)
Indoor
Outdoor
Indoor
Outdoor
Liquid line
Refrigerant piping
Gas line
kW
kW
Stars
dB(A)
dB(A)
dB(A)
l/s
mm
309x890x220
595x780(+62)x290
kg
mm
35
Clean Filter
45.5
Ø6.35
Ø9.52
Connection method
Refrigerant R410A
640x800(+71)x290
13.5
Ø12.7
Flare connection
Quantity
kg
Pre charged to pipe length
m
1.2
1.5
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
High Performance Air-Conditioning
9
Inverter Heat Pump.
SRK-ZMA-S
Wall mounted type
SRC63ZMA-S • SRC71ZMA-S
SRK63ZMA-S • SRK71ZMA-S
Single
Multi
Refrigerant Pipe Length
The SRK71ZMA-S can be selected for use with
the SCM Multi system outdoor unit.
Maximum Pipe Length
30m
20m
Maximum Height Different
SRK63ZMA-S • SRK71ZMA-S
Comfortable
Allergen Self Clean Allergen
St
SUN
Comfortable Air Flow
t Sp
ar
t
ur
FUNCTIONS
10
3HOT
Filter System Operation Filter
Keep
Convenience & Economy
Auto
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
Maintenance & Prevention
Economy
On Timer OFF Timer
24h Timer
DRY
Sleep
MC
Others
Self
Detachable
Diagnostic
Back-up
Auto
Switch Restart
Luminous
24h ION
Indoor
SRK63ZMA-S
SRK71ZMA-S
Outdoor
SRC63ZMA-S
SRC71ZMA-S
Power Supply
1 Phase 220~240V 50Hz
Cooling T1
Capacity
Input
Energy Label
EER
COP
Sound Power Level (JIS C9612)
Sound Pressure Level (JIS C9612)
Silent Mode Sound Pressure Level
Airflow
External Dimensions (HXWXD)
Net Weight
Heating H1
Clean Filter
SR series Air Conditioners 2014
7.1 (2.15~8.0)
7.1 (1.7~9.5)
8.0 (1.6~10.0)
7.52
7.70
Cooling T1
1.76 (0.54~2.30)
2.16 (0.54~2.80)
1.79 (0.37~3.30)
2.14 (0.37~3.40)
Heating H1
Cooling T1
kW
2.5
2
3
2.5
Cooling T1
3.58
3.29
Heating H1
3.97
3.74
Heating H2
2.43
2.49
62
66
Heating H1
Cooling (Outdoor)
Heating (Outdoor)
Cooling (Indoor)
Heating (Indoor)
Cooling(Outdoor)
Heating(Outdoor)
Cooling (Indoor)
Heating (Indoor)
Indoor
Outdoor
Indoor
Outdoor
Gas Line
Stars
dB(A)
dB(A)
dB(A)
l/s
mm
kg
mm
Connection Method
Refrigerant R410A
6.3 (2.15~7.1)
Heating H2
Liquid Line
Refrigerant Piping
kW
63
63
47-43-37-26
44-41-36-33
45
49-45-39-26
46-43-38-35
45
43
44
308-267-217-133
325-292-233-133
342-300-242-208
358-325-258-233
318x1098x248
750x880(+88)x340
16
57
Ø6.35
Ø15.88
Flare connection
Quantity
kg
Pre Charged To Pipe Length
m
1.8
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
Inverter Heat Pump Large Capacity.
Wall mounted type
Micro
PRODUCTS
SRK-ZMA-S
SRK80ZMA-S
SRC80ZMA-S
Refrigerant Pipe Length
Maximum Pipe Length
30m
20m
Maximum Height Different
SRK80ZMA-S
Allergen Self Clean Allergen
St
SUN
Comfortable Air Flow
t Sp
ar
t
ur
FUNCTIONS
Comfortable
3HOT
Filter System Operation Filter
Keep
Convenience & Economy
Auto
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
Maintenance & Prevention
Economy
On Timer OFF Timer
24h Timer
Sleep
DRY
MC
Self
Detachable
Diagnostic
Indoor
1 Phase 220~240V 50Hz
Cooling T1
Energy Label
EER
COP
Sound Power Level (JIS C9612)
Sound Pressure Level (JIS C9612)
Silent Mode Sound Pressure Level
Airflow
External Dimensions (Hxwxd)
Net Weight
Heating H1
8.0 (2.15~9.00)
kW
8.10
Cooling T1
2.35 (0.54~3.00)
Heating H1
Cooling T1
Heating H1
kW
Stars
2.57 (0.37~3.65)
2
2
Cooling T1
3.40
Heating H1
3.50
Heating H2
2.64
Cooling(Outdoor)
Heating(Outdoor)
Cooling(Indoor)
Heating(Indoor)
Cooling(Outdoor)
Heating(Outdoor)
Cooling(Indoor)
Heating(Indoor)
Indoor
Outdoor
Indoor
Outdoor
Gas line
dB(A)
dB(A)
dB(A)
l/s
mm
kg
mm
Connection method
Refrigerant R410A
9.0 (1.70~10.5)
Heating H2
Liquid line
Refrigerant Piping
Luminous
24h ION
SRC80ZMA-S
Power supply
Input
Back-up
Auto
Switch Restart
SRK80ZMA-S
Outdoor
Capacity
Others
Quantity
kg
m
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
70
51-47-41-26
48-45-40-37
48
50
350-308-250-133
392-342-283-250
318x1098x248
845x970x370
16
63
Ø6.35
Ø15.88
Flare connection
Pre charged to pipe length
Clean Filter
69
2.2
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
High Performance Air-Conditioning
11
Inverter Heat Pump Large Capacity.
SRK-ZMA-S
Wall mounted type
Blue
Fin
SRK92ZMA-S
SRC92ZMA-S
Refrigerant Pipe Length
Maximum Pipe Length
30m
20m
Maximum Height Different
SRK92ZMA-S
Comfortable
t Sp
ar
Allergen Self Clean Allergen
St
SUN
Comfortable Air Flow
t
ur
FUNCTIONS
12
3HOT
Filter System Operation Filter
Keep
Convenience & Economy
Auto
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
Maintenance & Prevention
Economy
On Timer OFF Timer
24h Timer
Sleep
DRY
MC
Self
Detachable
Diagnostic
Indoor
1 Phase 220~240V 50Hz
Cooling T1
Energy Label
EER
COP
Sound Power Level (JIS C9612)
Sound Pressure Level (JIS C9612)
Silent Mode Sound Pressure Level
Airflow
External Dimensions (Hxwxd)
Net Weight
9.2 (2.4~10.0)
Heating H1
kW
9.40
Cooling T1
2.54 (0.47~3.07)
kW
Heating H1
Cooling T1
Stars
Heating H1
Clean Filter
SR series Air Conditioners 2014
2.84 (0.43~3.76)
2.5
2
Cooling T1
3.62
Heating H1
3.52
Heating H2
2.80
Cooling(Outdoor)
dB(A)
Heating(Outdoor)
Cooling(Indoor)
dB(A)
Heating(Indoor)
Cooling(Outdoor)
dB(A)
Heating(Outdoor)
Cooling(Indoor)
l/s
Heating(Indoor)
Indoor
mm
Outdoor
Indoor
kg
Outdoor
mm
Gas line
Connection method
Refrigerant R410A
10.0 (2.2~11.2)
Heating H2
Liquid line
Refrigerant Piping
Luminous
24h ION
SRC92ZMA-S
Power supply
Input
Back-up
Auto
Switch Restart
SRK92ZMA-S
Outdoor
Capacity
Others
67
67
51-47-41-26
49-46-42-38
49
50
350-308-250-133
392-342-283-250
318x1098x248
1300x970x370
16
92
Ø6.35
Ø15.88
Flare connection
Quantity
kg
Pre charged to pipe length
m
3.15
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
Inverter Heat Pump.
PRODUCTS
SRK-ZMA-S
Wall mounted type
SRC20ZMA-S • SRC25ZMA-S
SRC35ZMA-S
Refrigerant Pipe Length
SRK20ZMA-S • SRK25ZMA-S • SRK35ZMA-S • SRK50ZMA-S
Maximum Pipe Length
Single
Multi
Most SRK-ZMA-S series can be selected for use
as indoor units in combination with the SCM Multi
system outdoor unit.
St
Allergen Self Clean Allergen
25m
15m
Maximum Height Different
SRK50ZMA-S
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
t
ur
FUNCTIONS
Maximum Pipe Length
Comfortable Air Flow
3HOT
Filter System Operation Filter
Auto
Keep
Convenience & Economy
Maintenance & Prevention
Economy
24h Timer
15m
10m
SRK20ZMA-S • SRK25ZMA-S •
SRK35ZMA-S
t Sp
ar
On Timer OFF Timer
Refrigerant Pipe Length
Maximum Height Different
Comfortable
SUN
SRC50ZMA-S
MC
Sleep
DRY
Others
Self
Detachable
Diagnostic
Back-up
Auto
Switch Restart
Luminous
24h ION
Indoor
SRK20ZMA-S
SRK25ZMA-S
SRK35ZMA-S
SRK50ZMA-S
Outdoor
SRC20ZMA-S
SRC25ZMA-S
SRC35ZMA-S
SRC50ZMA-S
2.0 (1.00~2.70)
2.5 (1.00~2.90)
3.3 (1.0~3.80)
5.0 (1.6~5.5)
2.7 (1.20~3.90)
3.2 (1.20~4.60)
4.0 (1.30~4.80)
5.8 (1.6~6.6)
Power Supply
1 Phase 220~240V 50Hz
Cooling T1
Capacity
Input
Energy Label
EER
COP
Sound Power Level (JIS C9612)
Sound Pressure Level (JIS C9612)
Silent Mode Sound Pressure Level
Airflow
External Dimensions (HXWXD)
Net Weight
Heating H1
Heating H2
3.23
3.79
4.04
5.19
Cooling T1
0.44 (0.21~0.77)
0.575 (0.27~0.81)
0.87 (0.21~1.20)
1.55 (0.40~2.20)
0.62 (0.27~1.38)
0.70 (0.27~1.36)
0.955 (0.29~1.45)
1.59 (0.42~2.10)
4
4
3
1.5
4
4.5
4
2.5
Heating H1
Cooling T1
Heating H1
kW
Stars
Cooling T1
4.55
4.35
3.79
3.23
Heating H1
4.35
4.57
4.19
3.65
Heating H2
2.64
2.62
2.80
2.40
59
58
60
61
58
59
61
63
Cooling (Outdoor)
Heating (Outdoor)
Cooling (Indoor)
Heating (Indoor)
Cooling (Outdoor)
Heating (Outdoor)
Cooling (Indoor)
Heating (Indoor)
Indoor
Outdoor
Indoor
Outdoor
Liquid Line
Refrigerant Piping
kW
Gas Line
dB(A)
dB(A)
dB(A)
l/s
mm
kg
33-27-24-21
34-28-24-21
45-32-26-22
46-37-28-25
36-31-24-21
39-31-24-21
42-37-25-22
45-37-31-27
42
41
45
43
45
42
43
45
130-93-88-80
132-100-88-83
190-107-90-83
188-130-100-88
163-105-83-75
183-108-85-77
213-157-102-80
225-170-125-103
294x798x229
540x780(+62)x290
640x800(+71)x290
9.5
31.5
35
41
Ø6.35
mm
Ø9.52
Connection Method
Refrigerant R410A
595x780(+62)x290
Ø12.7
Flare connection
Quantity
kg
Pre Charged To Pipe Length
m
0.75
Clean Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
1.15
1.35
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
High Performance Air-Conditioning
13
Inverter Heat Pump (High COP).
SRF-ZJX-S
Floor type
SRC25ZJX-S • SRC35ZJX-S
Refrigerant Pipe Length
Maximum Pipe Length
SRF25ZJX-S • SRF35ZJX-S • SRF50ZJX-S1
15m
10m
SRC50ZJX-S
Refrigerant Pipe Length
Maximum Pipe Length
Maximum Height Different
30m
20m
Maximum Height Different
SRF25ZJX-S • SRF35ZJX-S
Single
Multi
SRF50ZJX-S
All SRF-ZJX series can be selected for use as
indoor units in combination with the SCM Multi
system outdoor unit.
Comfortable
Self Clean
St
Enzyme SUN
3HOT
Filter Filter Operation
Convenience & Economy
Swing
Maintenance & Prevention
Economy
24h Timer
Auto Flap Memory UP/DOWN Lateral
Keep
On Timer OFF Timer
New models
coming soon!
Comfortable Air Flow
t Sp
ar
t
ur
FUNCTIONS
14
Sleep
DRY
MC
Self
Detachable
Diagnostic
Air outlet
selection
Others
Back-up
Auto Luminous
Switch Restart
Indoor
SRF25ZJX-S
SRF35ZJX-S
SRF50ZJX-S1
Outdoor
SRC25ZJX-S
SRC35ZJX-S
SRC50ZJX-S
Power supply
1 Phase 220~240V 50Hz
Cooling T1
Capacity
Input
Energy Label
EER
COP
Sound Power Level (JIS C9612)
Sound Pressure Level (JIS C9612)
Airflow
External Dimensions (HXWXD)
Net Weight
Heating H1
2.5 (0.9~3.2)
3.5 (0.9~4.1)
5.0 (1.1~5.2)
3.4 (0.9~4.7)
4.5 (0.9~5.1)
6.0 (0.6~6.9)
Heating H2
3.55
3.92
5.91
Cooling T1
0.521 (0.19~0.82)
0.890 (0.19~1.26)
1.390 (0.2~1.7)
0.723 (0.23~1.2)
1.124 (0.23~1.43)
1.540 (0.2~2.15)
4
2.5
2.5
4
3
3
4.80
3.93
3.60
Heating H1
Cooling
Heating
kW
Stars
Cooling T1
Heating H1
4.70
4.00
3.90
Heating H2
3.17
2.96
3.03
Cooling (Outdoor)
Heating (Outdoor)
Cooling (Indoor)
Heating (Indoor)
Cooling (Indoor)
Heating (Indoor)
Indoor
Outdoor
Indoor
Outdoor
Liquid Line
Refrigerant Piping
kW
Gas Line
dB(A)
dB
L/s
60
63
63
60
62
62
38-31-26
41-34-28
46-42-32
38-34-28
41-36-31
47-41-33
150-126-96
153-130-106
192-160-110
175-136-110
178-138-123
200-167-127
600X860X238
mm
kg
mm
595X780(+62)X290
19
38
Clean Filter
SR series Air Conditioners 2014
45
Ø6.35
Ø9.52
Connection Method
Refrigerant R410A
640X800(+71)X290
18
Ø12.7
Flare connection
Quantity
kg
Pe Charged To Pipe Length
m
1.2
1.5
15
Enzyme & Photocatalytic Washable Deodorizing Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
Inverter Heat Pump.
PRODUCTS
SRK-YL-S
Wall mounted type
SRC10YL-S • SRC13YL-S
SRK10YL-S • SRK13YL-S • SRK18YL-S
SRC18YL-S
Refrigerant Pipe Length
Maximum Pipe Length
FUNCTIONS
Comfortable
Comfortable Air Flow
Enzyme SUN
Filter Filter
Auto
Economy
On Timer OFF Timer
24h Timer
SRK10YL-S • SRK13YL-S •
SRK18YL-S
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
Convenience & Economy
Sleep
DRY
15m
10m
Maximum Height Different
Maintenance & Prevention
Others
Self
Detachable
Diagnostic
Back-up
Auto
Switch Restart
Luminous
24h ION
Indoor
SRK10YL-S
SRK13YL-S
SRK18YL-S
Outdoor
SRC10YL-S
SRC13YL-S
SRC18YL-S
Power supply
1 Phase 220~240V 50Hz
Capacity
Cooling T1
Input
Cooling T1
Energy Label
Cooling T1
EER
Cooling T1
Sound power level (JIS C9612)
Cooling(Outdoor)
Airflow
Cooling(Indoor)
External dimensions (HXWXD)
Net weight
Indoor
Outdoor
Indoor
Outdoor
Liquid line
Refrigerant piping
Gas line
kW
Stars
2.5 (1.0~2.7)
3.5 (1.0~3.7)
5 .0(1.6~5.5)
0.67 (0.21~0.88)
0.98 (0.21~1.24)
1.56 (0.40~2.20)
2.5
2.5
1.5
3.73
3.57
3.21
dB(A)
59
62
67
L/s
133-103-75
167-113-77
200-127-78
268x790x213
mm
kg
540x780(+62)x290
29
Clean Filter
9.5
32
35
Ø6.35
mm
Ø9.52
Connection method
Refrigerant R410A
595x780x(+62)x290
8.5
Ø12.7
Flare connection
Quantity
kg
Pre Charged To Pipe Length
m
0.7
0.95
1.3
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
High Performance Air-Conditioning
15
Inverter Heat Pump.
SRK-YMA-S
Wall mounted type
SRC24YMA-S
SRK24YMA-S
Refrigerant Pipe Length
Maximum Pipe Length
30m
20m
Maximum Height Different
SRK24YMA-S
Comfortable
FUNCTIONS
16
Comfortable Air Flow
Enzyme SUN
Filter Filter
Auto
Auto Flap Air Scroll Memory UP/DOWN Lateral Positioning
of
Swing
installation
Convenience & Economy
Economy
On Timer OFF Timer
24h Timer
Sleep
DRY
Indoor
Maintenance & Prevention
Others
Self
Detachable
Diagnostic
Back-up
Auto
Switch Restart
Luminous
24h ION
SRK24YMA-S
Outdoor
SRC24YMA-S
Power supply
1 Phase 220~240V 50Hz
Capacity
Cooling T1
Input
Cooling T1
Energy Label
Cooling T1
EER
Cooling T1
Sound power level (JIS C9612)
Cooling(Outdoor)
dB(A)
66
Sound pressure level (JIS C9612)
Cooling Indoor
dB(A)
49-45-39-26
Silent Mode Sound Pressure
Cooling Outdoor
dB(A)
45
Airflow
Cooling(Indoor)
L/s
325-292-233-133
External dimensions (HXWXD)
Net weight
Indoor
Outdoor
Indoor
Outdoor
Liquid line
Refrigerant piping
Gas line
kW
Stars
mm
kg
mm
kg
Pre Charged To Pipe Length
m
SR series Air Conditioners 2014
318x1098x248
750x880(+88)x340
16
56
Ø6.35
Ø15.88
Flare connection
Quantity
Clean Filter
2
3.29
Connection method
Refrigerant R410A
7.1 (2.15~8.0)
2.16 (0.54~2.80)
1.8
15
Allergen Clear & Photocatalytic Washable Deodorizing Filter
Manufacturers Specifications: All specfication tables are at nominal conditions. Refer to manufacturers technical manuals.
Control Options.
Wired remote control can be connected
Interface
SRK63~92ZMA-S
SRK20~60ZMXA-S
SRK20~50ZMA-S
SRK24YMA-S
PRODUCTS & CONTROL OPTIONS
Model
interface
Remote Control
RC-E5
SC-BIKN-EA
RC-EX1A
Can connect to SUPERLINK-II
Model
Interface
Remote Control
SRK63~92ZMA-S
SRK20~60ZMXA-S
SRK20~50ZMA-S
SRK24YMA-S
SC-BIKN-EA
SC-ADNA-E
RC-E5
RC-EX1A
SC-BIKN-EA
RC-EX1A
Back
Light
SC-BIKN-EA
SC-SL2NA-E
RC-EX1A
RC-E5
SC-ADNA-E
SC-ADNA-E
CnT terminal is equipped on interface kit of SC-BIKN-EA
common
CnT
XR1
XR2
XR3
XR4
XR1
XR2
output1 (run)
output2 (heat)
XR3
XR4
output3 (comp on)
output4 (alarm)
in put
XR5
Model
Power
source
XR5
XR1~4 : DC12v XR5 : 220~240V
SRK63~92ZMA-S
SRK20~60ZMXA-S
SRK20~50ZMA-S
SRK24YMA-S
Interface
SC-BIKN-EA
HOTEL
HOTEL
Remote surveillance system
Card key on-off
Humidifier linkage
High Performance Air-Conditioning
17
Functions.
Filter
Allergen
Filter
SUN
Filter
Allergen Clear Filter
The filter breaks down the pollen, lice, and all allergens that live on cat skins, etc. and
deactivates them.
Photocatalytic Washable Deodorizing Filter
It keeps air fresh by deodorizing the molecules causing odor. The deodorizing ability can be
easily restored simply by cleaning and exposing the filter to the sunlight.
Enzyme
Filter
Allergen
Natural Enzyme Filter
Enzymes used in the filter are naturally occurring lytic enzymes which attack cell walls of
microorganisms trapped on the filter and destroy them.
Self Clean
Allergen System
Suppresses the influence of the allegen caught by the filter.
System Operation Self Clean
The indoor fan continues to operate on ultra low speed to dry the unit.
Comfortable Functions
Fuzzy Auto Mode
“HI POWER” Operation
Automatically the unit determines its operating mode and temperature setting based on a fuzzy
calculation and adjusts the inverter frequency.
Automatic Operation
TThe unit can operate continuously in HI POWER mode for 15 minutes. This mode is used to
reach the desired temperature quickly.
The air conditioner automatically selects from heating, cooling or dry operation.
t
ur
t Sp
ar
St
18
3HOT
Keep
Three “Hot” System
‘Hot start’ enables the unit to begin heating operation quickly. ‘Hot spurt’ is a fast heating
system that works to increase the temperature setting by two degrees. ‘Hot keep’ is used during
the automatic defrost cycle to prevent cool air being circulated. These three operational control
systems help ensure comfortable and efficient heating.
Comfortable Air Flow Functions
3D Auto
Memory
You can choose the best heating or cooling pattern with the touch of a button.
Auto
COOLING & DRY
Horizontal blowing
Auto Flap Auto Flap Mode
The unit automatically selects the optimal
angle whatever the operation mode.
Air Scroll Air Scroll
While the flap is swinging it can be stopped at any angle. The flap returns to this position next
time the unit starts.
UP/DOWN Up/Down Flap Swing
The Up/Down flap can be adjusted to the
preferred angle anywhere between horizontal
and perpendicular.
HEATING
Slant forward
blowing
Lateral
Swing
The swing of the flap causes the air flow to
spiral and the breeze to reach all corners
of the room.
Air outlet
selection
COOLING & DRY
Thick line
: moves quickly
Thin line
: moves slowly
HEATING
Thick line
Thin line
Memory Flap
Positioning
of
installation
: moves quickly
: moves slowly
SWING FLAP
Flap moves up and down
continuously.
Lateral Swing
The louver swings from right to left automatically. Louver angle can be fixed in any desired
position.
Air Outler Selection
Both lower and upper air outlets and upper air outlet can be selected. (SRF models only)
Positioning of Installation
You can set the left-right air flow directions when you install the air conditioner near the side
wall by remote controller operation.
Convenience & Economy Functions
On Timer On Timer
This enables the operation to start a little earlier so that
the room is near to the set temperature at ON time.
24-hour On/Off Programmable Timer
24h Timer
OFF Timer Off Timer
The unit stops at the specified time.
Weekly Timer
Up to 4 programs with timer operation (ON-TIMER/
OFF-TIMER) are available for each day of the week. MAX
28 programs per week can be set.
By combining a start timer with a stop timer you can
register two timer operations a day. Once set timers will
start or stop the system at the specified time of the day
repeatedly.
Economy Economy Mode
Dry Operation
DRY
The unit dehumidifies the room by intermittent cooling
operation.
The unit achieves effective energy saving operation while
still keeping a comfortable cooling or heating operation.
Sleep
Silent Operation
The sound level of outdoor units is at least 3dB(A) lower
than the nominal level.
Sleep Mode
The room temperature is automatically controlled during
the set sleep mode period ensuring that the room
temperature will not get too hot or cold.
Night Setback
During cold seasons, room temperatures can be
maintained at a comfortable level even while the room is
unattended. The air conditioner keeps the temperature
at 10°C.
Maintenance & Prevention Functions
MC
Microcomputer-Operated Defrosting
This function automatically eliminates frost and helps minimize excessive operation in other
modes.
Self-Diagnostic Function
Self
Diagnostic If the air conditioner malfunctions an internal microcomputer runs a self diagnosis. Inspection
and repair should be performed by authorized dealers.
Detachable Detachable Indoor Air Inlet Panel
The air inlet panel on the indoor unit opens and closes easily making filter cleaning simple. The
suction panel can be easily removed.
When removing the air inlet panel for internal
cleaning or other reasons, open the grill by 65
degrees and then pull it to the side.
Others
Back-up Back-up Switch
Switch On the indoor unit there is a back up on/off switch. The system will operate in the previous
mode.
Auto Restart Function
Auto
Restart Power blackout auto restart function records the operational status of the air conditioner
immediately prior to being switched off by a power supply interruption. The unit automatically
resumes operations in the mode and temperature set point after the power has been restored.
SR series Air Conditioners 2014
24-hour ION
24h ION
The air conditioner body has a tourmaline coated sheet. Negative ions (2,500 -3,000/cc) are
generated when the air conditioner is not running, allowing you to experience them without
incurring any electrical cost.
Luminous Luminous Button
With wireless “Luminous” remote controls that even “glow in the dark”, it is possible to operate
all desired functions of the unit with the click of a button.
SCM.
Multi Residential Air Conditioner.
FUNCTIONS & OTHER PRODUCTS
Compact
A Mitsubishi Heavy Industries inverter multi-split system allows 2 to 6 indoor units to be connected to a single
outdoor unit. This allows multiple rooms to be conditioned without adding clutter to the exterior of your home.
One compact multi-split outdoor unit instead of many outdoor units not only adds to the asthetic appeal your
home but can be imperative when there is not much space available, for example, when installing outdoor
units on balconies or verandahs.
Installation Flexibility
With a generous maximum piping length of 70m*, you are given greater freedom to decide where the indoor
units will be installed to optimise interior space and convenience. In addition, a maximum height difference of
25m* for the indoor units means the Mitsubishi Heavy Industries inverter multi-split system can easily service
the rooms for multi storey homes.
*Please check model specifications as these pipe lengths and height differences do not apply to all models.
Variety of Indoor Units
The indoor unit range includes wall mounted, floor standing, low static bulkhead or compact cassette types
in a wide range of capacities. This makes hundreds of combinations possible for your home. You can choose
the right type of indoor unit to complement the interior décor and match the size of each room.
Independent Control and Comfort
Each indoor unit comes with its own remote allowing the unit to be independently switched on/off and
have the temperature adjusted as needed. The conditions of rooms can vary greatly depending on many
variables such as the number of occupants or the way the room is used. With a range of comfort, air flow
and convenience functions on each indoor unit, you can adjust the settings to match the requirements of a
room without affecting other ones. When a room is unoccupied you can switch off the unit to reduce inefficient
energy use.
5 Year Warranty
When you buy a Mitsubishi Heavy Industries inverter multi-split system, you are getting an air conditioning
solution from a company that some of the highest quality products in the industry. Mitsubishi Heavy Industries
enjoys a reputation for outstanding quality and is highly respected both in the Australian and overseas markets.
With our 5 Year Warranty covering the parts, labour and compressor, you can peace of mind that your new
Mitsubishi Heavy Industries inverter multi-split system will continue to deliver air-conditioning comfort to your
home through the years.
Please go to our website for more details.
High Performance Air-Conditioning
19
Before starting use
Heating performance
Refrigerant leakage
The heating performance values (kW) described in catalog are the values
obtained by operating at an outdoor temperature of 7C and indoor temperature
of 20C as set forth in the ISO Standards. As the heating performance decreases
as the outdoor temperature drops, if the outdoor temperature is too low and the
heating performance is insufficient, use other heating appliances as well.
The refrigerant (R410A) used for Air conditioner is non-toxic and nonflammable
in its original state.
However, in consideration of a state where the refrigerant leaks into the room,
measures against refrigerant leaks must be taken in small rooms where the
tolerable level could be exceeded. Take measures by installing ventilation
devices, etc.
Indication of sound values
The sound values are the values (A scale) measured in a chamber such as an
anechoic chamber following the ISO Standards. In the actual installation state,
the value is normally larger than the values given in the catalog due to the effect
of surrounding noise and echo. Take this into consideration when installing.
Use in oil atmosphere
Avoid installing this unit in as atmosphere where oil scatters or builds up, such
as in a kitchen or machine factory.
If the oil adheres to the heat exchanger, the heat exchanging performance will
drop, mist may be generated, and the synthetic resin parts may deform and
break.
Use in snowy areas
Take the following measures when installing the outdoor unit in snowy areas.
Snow prevention
Install a snow-prevention hood so that the snow does not obstruct the air intake
port or enter and freeze in the outdoor unit.
Snow piling
In areas with heavy snow fall, the piled snow could block the air intake port. In
this case, a frame that is 50cm or higher than the estimated snow fall must be
installed underneath the outdoor unit.
Automatic defrosting device
Use in acidic or alkaline atmosphere
If this unit is used in acidic atmosphere such as hot spring areas having high
level of sulfuric gases or in alkaline atmosphere including ammonia or calcium
chloride, places where the exhaust of the heat exchanger is sucked in, or at
coastal areas where the unit is subject to salt breezes, the outer plate or heat
exchanger, etc., will corrode. Please ask a dealer or specialist when you use an
air conditioner in places differing from a general atmosphere.
If the temperature is low, and the humidity is high, frost will stick to the heat
exchanger of the outdoor unit. If use is continued, the heating performance will
drop.
The “Automatic defrosting device” will function to remove this frost.
After heating for approx, three to ten minutes, it will stop, and the frost will be
removed. After defrosting, hot air will be blown again.
Use in places with high ceilings
Servicing the air-conditioner
After the air-conditioner is used for several seasons, dirt will build up in the
air-conditioner causing the performance to drop. In addition to regular servicing,
we recommend the maintenance contract (charged for) by a specialist.
If the ceiling is high, install a circulator to improve the heat and air flow
distribution when heating.
Safety Precautions
Air-conditioner usage target
Installation
The air-conditioner described in this catalog is a dedicated cooling/heating
device for human use.
Do not use it for special applications such as the storage of foodstuffs, animals
or plants, computer server rooms, precision devices or valuable art, etc.
This could cause the quality of the items to drop, etc.
Do not use this for cooling vehicles or ships. Water leakage or current leaks
could occur.
Always commission the installation to a dealer or specialist. Improper
installation will lead to water leakage, electric shocks and fires.
Make sure that the outdoor unit is stable in installation. Fix the unit to stable
base.
Before use
Always read the “User,s Manual” thoroughly before starting use.
Usage place
Do not install in places where combustible gas could leak or where there are
sparks.
Installation in a place where combustible gas could be generated, flow or
accumulate, or places containing carbon fibers could lead to fires.
Only persons that are qualified and licensed are permitted to install and service products that contain refrigerants in Australia, go to www.arctick.org.
Suitable access for service must be provided in compliance with industry standards and local regulations.
MHIAA is proudly sponsoring
Monika’s Doggie Rescue
Australia:
New Zealand:
ABN 92 133 980 275
G.S.T. 105-673-620
Phone: 1300 138 007 Fax: 1800 644 329
Phone: 0800 138 007 Fax: 09 442 5346
NSW & Head Office
Victoria
Brisbane
Townsville
Western Australia
Auckland
9C Commercial Road
Kingsgrove NSW 2208
PO Box 318 Kingsgrove
NSW 1480
2/24 Lakeside Drive
Burwood East
VIC 3151
5/26 Flinders Parade
North Lakes
QLD 4509
12/31 Fleming Street
Aitkenvale
QLD 4812
PO Box 1386 Aitkenvale
QLD 4814
Unit 3A 2 Mulgul Rd
Malaga WA 6090
PO Box 2089 Malaga
WA 6944
Unit 2 100 Bush Road
Albany 0632
PO Box 300552
Albany 0632
www.mhiaa.com.au
MRE SPARE PARTS
www.mrespareparts.com.au
ISO9001
Tel: +61 (0) 2 9600 7444
Fax: +61 (0) 2 9600 8044
ISO14001
Mitsubishi Heavy Industries, Ltd.
Air-conditioning & Refrigeration Systems Headquarters
Certified ISO 9001
Certificate number : JQA-0709
MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO., LTD.
Certified ISO 9001
Certificate Number : 04100 1998 0813
Mitsubishi Heavy Industries, Ltd.
Air-conditioning & Refrigeration Systems Headquarters
Certified ISO 14001
Certificate number : JQA-EM0256
MITSUBISHI HEAVY INDUSTRIESMAHAJAK AIR CONDITIONERS CO.,LTD.
Certificate Number : 04104 1998 0813 E5
P
ISO 14001
Certificate 04104 1998 0813 E5
BIWAJIMA PLANT
nd Lab
ou
ts a
ar
5
Ye
a
r Wa r r a n
ty
MHIAA412_SR 2014
BIWAJIMA PLANT
Our Air Conditioning &
Refrigeration Systems
Headquarters has been
assessed and found to
comply with the
requirements of
ISO14001.
r
Our Air Conditioning &
Refrigeration Systems
Headquarters is an ISO9001
approved factory for residential
air conditioners and
commercial-use air
conditioners (including heat
pumps).
www.mhiaa.co.nz
Because of our policy of continuous improvement, we reserve the right to make changes in all specifications without notice. E&OE.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising