Basic Plus2 Room Thermostats Floor Heating

Basic Plus2 Room Thermostats Floor Heating
MAKING MODERN LIVING POSSIBLE
User Guide
Basic Plus2 Room Thermostats Floor Heating
www.heating.danfoss.com
The English language is used for the original instructions.
Other languages are a translation of the original instructions.
(Directive 2006/42/EC)
© 2014 Copyright Danfoss A/S
User Guide
Basic Plus2 Room Thermostats Floor Heating
Table of Contents
1
Functional Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
2
Power ON/OFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
3
Set Desired Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
4
Select Away Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
5
Set Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
6
Advanced Programmable Timer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
7
Check Floor Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
8
Child Safety Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
9
Set Control Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
10
Error Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5
1
Functional Overview
Symbols Function description
Symbols Function description
Mode change/check floor temp./child safety lock/ parameters setting
Room temperature
Floor temperature
Up/down selectors
Temperature indication
Set temperature
Floor heating - Active
Frost protection - Active
Away mode
Child safety lock
Power ON/OFF
Timer and program operation
2
Power ON/OFF
▪ Turn the thermostat ON or OFF by pressing
3
.
Set Desired Temperature
▪ Press “<” or ”>” at any time to change the desired temperature value. "SET" is shown in the display.
▪ When releasing “<” or ”>”, the display returns to showing the
actual temperature.
▪ The adjustment step is 0.5 °C.
Danfoss Heating Solutions
VUCUA102
3
User Guide
4
Basic Plus2 Room Thermostats Floor Heating
Select Away Mode
▪ Press “M” to enter away mode and
will be displayed.
▪ Press ”<” or ”>”. “SET” appears; set the away mode setpoint.
▪ Press “M” again to exit away mode.
5
Set Timer
For WT-P and WT-PR variants only
▪ Press ; “hh” flashes. Press”<” or ”>” to adjust hour. Press
again; ”mm” flashes. Press ”<” or ”>” to adjust minute. Press
again; “week” flashes. Press ”<” or ”>” to adjust week.
▪ Complete all adjustments. Press any other button to exit (automatic exit after 6 seconds with no operation).
6
Advanced Programmable Timer
For WT-P and WT-PR variants only
The Advanced Programmable Timer mode enables the setting of a
timer-controlled program for automatic comfort temperature, and
an energy-saving lower setback temperature if standard room
comfort temperature is not required.
▪ The function consists of 2 programs:
▪ Program 1: 4 events in 5 days (Mon. Tue. Wed. Thu. Fri.)
▪ Program 2: 4 events in 2 days (Sat. Sun.)
▪ Program 1: Press
to display Mo. Tu. We. Th. Fr.
▪ Program 1, Event 1:
▪ Use ”<” or”>” to select the required start time.
▪ Press
to accept setting.
Use
”<”
or
”>” to select the required temperature.
▪
▪ Press
to accept setting.
▪ Program 1, Event 2-4:
▪ Repeat the Event 1 procedure for programming Event
2-4.
▪ Program 2: Sa. Su. are now shown in the display.
▪ Program 2, Event 1:
▪ Use ”<” or ”>” to select the required start time.
▪ Press
to accept setting.
▪ Use ”<” or ”>” to select the required temperature.
▪ Press
to accept setting.
7
▪ Program 2, Event 2-4:
▪ Repeat the Event 1 procedure for programming Event
2-4.
▪ The thermostat will continue the 4-event program based on
the present time and day.
▪ To set and change the desired room temperature temporarily:
▪ Press “<” or ”>” at any time to change the desired temperature value. "SET" is shown in the display.
▪ When releasing the “<” or ”>”, the display returns to
showing the actual temperature. This temperature
change is only temporary and will be maintained only
until the next programmed setting!
▪ A default program provides timer control if the customer
does not set own programs. The default program is as follows.
Event 1
Event 2
Weekday,
Mon-Fri.
6:30/20 °C
(27 °C)*
8:30/15 °C
(25 °C)*
16:30/20 °C
(27 °C)*
22:30/15 °C
(25 °C)*
Weekend,
Sat. -Sun.
7:30/20 °C
(27 °C)*
9:30/20 °C
(27 °C)*
16:30/21 °C
(28 °C)*
22:30/15 °C
(25 °C)*
Weekday/
Weekend
Event 3
Event 4
Start time/temp.
* Floor temperature control mode.
Check Floor Temperature
Press “M” and hold. Press “<” within 6 seconds.
flashes and the current floor temperature is displayed. Operate
again, then exit (automatic exit after 6 seconds with no operation).
4
VUCUA102
Danfoss Heating Solutions
User Guide
8
Basic Plus2 Room Thermostats Floor Heating
Child Safety Lock
Press “M” and hold. Press “>” within 6 seconds to lock all buttons.
Operate again to exit the child safety lock.
9
Set Control Parameters
Press "M" button for 6 seconds to enter the parameter setting
mode. Press "M" for parameter selection and set the parameter
range via "<" or ">". Complete all adjustments. To exit WT-P/PR,
press , which is available for this purpose (automatic exit after
30 seconds with no operation). To exit WT-D/DR, wait for automatic exit (30 seconds). The upper digits indicate the parameter number. The digits indicate the set value as follows.
No. Parameter settings
Settings range
P01 Working mode
P02 Temperature control mode
Factory default
WTD/DR
WTP/PR
01: Manual ; 02: APT
NA
02
01: Only room temp.;
02: Room and floor
temp.; 03: Only floor
temp.
01
01
No. Parameter settings
Settings range
P03 High room temp.
limit
Factory default
WTD/DR
WTP/PR
5-35 °C (only for 01and
02 in P02)
30 °C
30 °C
P04 Low room temp.
limit
5-35 °C (only for 01and
02 in P02)
5 °C
5 °C
P05 Floor temp. limitation mode
01: High temp. limitation: 02: Low temp. limitation (only for 02 in
P02)
01
01
P06 Floor temp. limitation setpoint
20-45 °C (only for 02 in
P02)
35 °C
35 °C
P07 High floor temp.
limit
20-45 °C (only for 03 in
P02)
35 °C
35 °C
P08 Low floor temp.
limit
20-45 °C (only for 03 in
P02)
20 °C
20 °C
P09 Frost protection
01: Enable; 02: Disable
01
01
P10 Frost protection
setpoint
5-17 °C
5 °C
5 °C
P11 Timer display option
01: 24 h; 02: 12 h
NA
01
P12 Room temp. display option at
shutdown
01: No display current
temp.; 02: Display current temp.
01
01
P03 to P08 appear on relevant temperature control mode.
10
Error Messages
Error messages are displayed as follows:
▪ E1 = room sensor failure
▪ E2 = floor sensor failure
▪ EE = EEPROM failure
▪ Lo = temperature lower than 0 °C
▪ HI = temperature higher than 50 °C
All relay output will be turned off in all cases.
Danfoss Heating Solutions
VUCUA102
5
User Guide
6
Basic Plus2 Room Thermostats Floor Heating
VUCUA102
Danfoss Heating Solutions
User Guide
Danfoss Heating Solutions
Basic Plus2 Room Thermostats Floor Heating
VUCUA102
7
User Guide
Basic Plus2 Room Thermostats Floor Heating
Danfoss A/S
Heating Solutions
Haarupvaenget 11
8600 Silkeborg
Denmark
Phone: +45 7488 8000
Fax: +45 7488 8100
Email: heating.solutions@danfoss.com
www.heating.danfoss.com
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed. All trademarks in this material are property of the respective
companies. Danfoss Heating Solutions and the Danfoss Heating Solutions logotype are trademarks of Danfoss A/S. All rights reserved.
VUCUA102
Produced by Danfoss Heating Solutions © 08/2014
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising