ETERNUS Disk storage systems Server Connection Guide

ETERNUS Disk storage systems Server Connection Guide
Preface
This document briefly explains the operations that need to be performed by the user in order to
connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or
ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system to an
Industry Standard Server running Windows®.
This document should be used in conjunction with other applicable user manuals such as those
for the ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or
ETERNUS8000 model 700, 800, 900, 1100, 1200, 2100, or 2200 Disk storage system, server,
OS used, Fibre Channel cards, drivers, etc.
This document references the following documents:
• Server Support Matrix
• ETERNUS Disk storage systems Server Connection Guide (Fibre Channel)
ETERNUS Disk Storage System Settings
• ETERNUS Disk storage systems Server Connection Guide (Fibre Channel)
for Windows®
Also, note that in this document the ETERNUS2000 models 100 and 200, ETERNUS4000
models 300, 400, 500, and 600, and ETERNUS8000 models 700, 800, 900, 1100, 1200, 2100,
and 2200 Disk storage systems are collectively referred to as ETERNUS Disk storage systems.
Fifth Edition
April 2010
The Contents and Structure of this Manual
This document is composed of the following three chapters and an appendix.
•
Chapter 1 Workflow
This describes how to connect an ETERNUS Disk storage system to a PRIMERGY or
PRIMEQUEST 1000 series server.
•
Chapter 2 Setup Procedure for PRIMERGY
This describes how to install a Fibre Channel card, set up the Fibre Channel card BIOS,
install the Fibre Channel card driver, check the driver version, and set up the driver
parameters for PRIMERGY.
•
Chapter 3 Setup Procedure for PRIMEQUEST 1000 series
This describes how to install a Fibre Channel card, set up the Fibre Channel card BIOS,
install the Fibre Channel card driver, check the driver version, and set up the driver
parameters for PRIMEQUEST 1000 series.
An appendix contains a WWN instance management table for servers, for use in the "Installing
the Fibre Channel Card" section.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
3
Copyright 2010 FUJITSU LIMITED
Preface
Safe Use of this Product
■ Using this manual
This manual contains important information to ensure the safe use of this product. Be sure to
thoroughly read and understand its contents before using the product. After reading, store this
manual in a safe place for future reference.
FUJITSU has made every effort to ensure the safety of the users and other personnel, and to
prevent property damage. When using this product, carefully follow the instructions described in
this manual.
Acknowledgments
• Microsoft, Windows, and Windows Server are either registered trademarks or trademarks of
Microsoft Corporation in the U.S. and/or other countries.
• Emulex is a trademark of Emulex Corp.
• QLogic is a trademark of QLogic Corp.
• The company names, product names and service names mentioned in this document are
registered trademarks or trademarks of their respective companies.
Naming Conventions
■ OS names
• "Windows Server® 2008 R2" represents the following products.
- Microsoft® Windows® Web Server 2008 R2
- Microsoft® Windows Server® 2008 R2 Standard
- Microsoft® Windows Server® 2008 R2 Enterprise
- Microsoft® Windows Server® 2008 R2 Datacenter
- Microsoft® Windows Server® 2008 R2 for Itanium-based Systems
• "Windows Server® 2008" represents the following products.
-
Microsoft® Windows Server® 2008 Standard
Microsoft® Windows Server® 2008 Enterprise
Microsoft® Windows Server® 2008 Datacenter
Microsoft® Windows Server® 2008 for Itanium-based Systems
• "Windows Server® 2003" represents the following products.
-
Microsoft® Windows Server® 2003, Standard Edition
Microsoft® Windows Server® 2003, Enterprise Edition
Microsoft® Windows Server® 2003, Standard x64 Edition
Microsoft® Windows Server® 2003, Enterprise x64 Edition
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
4
Copyright 2010 FUJITSU LIMITED
Preface
-
Microsoft® Windows Server® 2003 R2, Standard Edition
Microsoft® Windows Server® 2003 R2, Enterprise Edition
Microsoft® Windows Server® 2003 R2, Standard x64 Edition
Microsoft® Windows Server® 2003 R2, Enterprise x64 Edition
Microsoft® Windows Server® 2003, Enterprise Edition for Itanium-based Systems
Microsoft® Windows Server® 2003, Datacenter Edition for Itanium-based Systems
Microsoft® Windows® Storage Server 2003 R2, Standard Edition
Microsoft® Windows® Storage Server 2003 R2, Enterprise Edition
Microsoft® Windows® Storage Server 2003 R2, Standard x64 Edition
Microsoft® Windows® Storage Server 2003 R2, Enterprise x64 Edition
• "Windows® 2000" represents the following products.
- Microsoft® Windows® 2000 Server operating system
- Microsoft® Windows® 2000 Advanced Server operating system
■ Other names
• "Channel Adapter" (CA) refers to the Fibre Channel interface module used in the ETERNUS
Disk storage systems to connect to the server.
• "Fibre Channel card" refers to the Fibre Channel interface module normally used in the
server. A "Host Bus Adapter" (HBA) or "Channel Adapter" (CA) may be used instead,
depending on the server.
• "Fibre Channel cable" refers to the cable that is used to connect the ETERNUS Disk storage
systems and server via a Fibre Channel interface. "FC cable", "optical fibre cable", or "multi
mode Fibre Channel cable" may be used instead, depending on the storage system.
• Italics are used to show variables such as values and characters that appear in command
parameters and output examples.
Screen shot(s) reprinted with permission from Microsoft Corporation.
Copyright 2010 FUJITSU LIMITED
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
5
Copyright 2010 FUJITSU LIMITED
Contents
Chapter 1
Workflow ...................................................................................7
Chapter 2
Setup Procedure for PRIMERGY.............................................9
2.1
2.1.1
2.1.2
2.1.3
2.1.4
2.1.5
2.1.6
2.2
2.2.1
2.2.2
2.2.3
2.2.4
Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards ................... 9
Installing the Fibre Channel Card .............................................................................................. 10
Installing the Drivers .................................................................................................................. 11
Checking the Driver Version ...................................................................................................... 12
Setting up the Driver Parameters .............................................................................................. 12
Setting Fixed Target IDs (for Windows Server® 2008 and Windows Server® 2003) ................ 18
Installing the ETERNUS Disk Storage System Driver ............................................................... 18
Setup Procedure for the S26361-F3023-E1 Fibre Channel Card .................... 19
Installing the Fibre Channel Card .............................................................................................. 19
Installing the Drivers .................................................................................................................. 23
Checking the Driver Version ...................................................................................................... 23
Installing the ETERNUS Disk Storage System Driver ............................................................... 23
Chapter 3
3.1
3.1.1
3.1.2
3.1.3
3.1.4
3.1.5
3.1.6
Setup Procedure for PRIMEQUEST 1000 series..................24
Setup Procedure for MC-0JFC11 and MC-0JFC21 Fibre Channel Cards ....... 24
Installing the Fibre Channel Card .............................................................................................. 25
Installing the Drivers .................................................................................................................. 26
Checking the Driver Version ...................................................................................................... 27
Setting up the Driver Parameters .............................................................................................. 27
Setting Fixed Target IDs (for Windows Server® 2008 and Windows Server® 2003) ................ 29
Installing the ETERNUS Disk Storage System Driver ............................................................... 29
Appendix A WWN Instance Management Table for the Server
(Blank) .....................................................................................30
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
6
Copyright 2010 FUJITSU LIMITED
Chapter 1
Workflow
This chapter describes how to install and set up the Fibre Channel cards in a PRIMERGY or
PRIMEQUEST 1000 series server.
Workflow
Install the Fibre Channel Card
Install the Fibre Channel card and its driver, check the driver version, and set up the Fibre
Channel card BIOS.
Refer
• For PRIMERGY
- For the S26361-F2624-E1, S26361-F2843-E1/S26361-F2843-E201, S26361-F3141E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961E202, S26361-F3306-E601, or MC-FC82E Fibre Channel card
• "2.1.1 Installing the Fibre Channel Card" (page 10)
• "2.1.2 Installing the Drivers" (page 11)
- For the S26361-F3023-E1 Fibre Channel card
• "2.2.1 Installing the Fibre Channel Card" (page 19)
• "2.2.2 Installing the Drivers" (page 23)
• For PRIMEQUEST 1000 series
- For the MC-0JFC11 or MC-0JFC21 Fibre Channel card
• "3.1.1 Installing the Fibre Channel Card" (page 25)
• "3.1.2 Installing the Drivers" (page 26)
For PRIMERGY
(not S26361-F3023-E1)
or
For PRIMEQUEST 1000 series
(MC-0JFC11 or MC-0JFC21)
For PRIMERGY
(S26361-F3023-E1)
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
7
Copyright 2010 FUJITSU LIMITED
Chapter 1 Workflow
>
Set the Fibre Channel Card Driver
Parameters
Set the Topology, Queue Depth and other
parameters.
Refer
• For PRIMERGY
- "2.1.4 Setting up the Driver
Parameters" (page 12)
• For PRIMEQUEST 1000 series
- "3.1.4 Setting up the Driver
Parameters" (page 27)
Install the ETERNUS Disk Storage System Driver
Install the ETERNUS Disk Storage System Driver.
Refer
• For PRIMERGY
- For the S26361-F2624-E1, S26361-F2843-E1/S26361-F2843-E201, S26361-F3141E10/S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306E201, S26361-F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961E202, S26361-F3306-E601, or MC-FC82E Fibre Channel card
• "2.1.6 Installing the ETERNUS Disk Storage System Driver" (page 18)
• Check the driver-related notes.
"ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for
Windows®"
- For the S26361-F3023-E1 Fibre Channel card
• "2.2.4 Installing the ETERNUS Disk Storage System Driver" (page 23)
• Check the driver-related notes.
"ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for
Windows®"
• For PRIMEQUEST 1000 series
- For the MC-0JFC11 or MC-0JFC21 Fibre Channel card
• "3.1.6 Installing the ETERNUS Disk Storage System Driver" (page 29)
• Check the driver-related notes.
"ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for
Windows®"
Once all these steps have been completed, proceed as described in "ETERNUS Disk
storage systems Server Connection Guide (Fibre Channel) for Windows®".
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
8
Copyright 2010 FUJITSU LIMITED
Chapter 2
Setup Procedure for PRIMERGY
The setup procedure varies depending on the product ID of the Fibre Channel card being used.
• For the S26361-F2624-E1, S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/
S26361-F3141-E210, S26361-F3141-E1, S26361-F3306-E1/S26361-F3306-E201, S26361F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306E601, and MC-FC82E Fibre Channel cards, proceed to "2.1 Setup Procedure for nonS26361-F3023-E1 Fibre Channel Cards" (page 9).
• For the S26361-F3023-E1 Fibre Channel card, proceed to "2.2 Setup Procedure for the
S26361-F3023-E1 Fibre Channel Card" (page 19).
2.1
Setup Procedure for non-S26361-F3023-E1 Fibre
Channel Cards
Install the Fibre Channel cards in the server, and acquire their physical addresses and World
Wide Names (WWNs).
The physical address and WWN of a Fibre Channel card are required information in the following
cases: when an error has occurred in the system, when using the ETERNUS Disk storage systems (security function, host affinity function, etc.) to restrict server access, or when connecting
the ETERNUS Disk storage systems and the server using Fibre Channel switch.
Acquire the physical address and WWN when installing the Fibre Channel card, because they
cannot be determined from BIOS and OS.
Physical address and WWN must be assigned to "WWN instance management table for the
server".
(1) Install the Fibre Channel card
(2) Turn on the server
(3) Acquire the physical address and WWN for the Fibre Channel card
(4) Add a record for the server in the WWN instance management table for the server
When installing two or more Fibre Channel cards to the server, first turn off the server, then
repeat Steps (1) through (4) above for each Fibre Channel card to be installed.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
9
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
2.1.1
Installing the Fibre Channel Card
For the installation method, position (PCI bus slots), and notes regarding the Fibre Channel card,
refer to the Fibre Channel card documentation or the User Guide of the server.
Procedure
1
Turn on the server, and press the [Alt] + [E] keys while the following message is
displayed.
!!! Emulex LPexxxx BIOS Copyright xxxx !!! xxxxxxxx
Press <Alt E> to go to Emulex BIOS Utility.
Press <s> to skip Emulex BIOS.
"LightPulse BIOS Utility" starts.
2
Enter the number of the Fibre Channel card to be checked in [Enter a
Selection:_] and press the [Enter] key.
3
Check the [I/O Base] and [Port Name] values.
The value of [I/O Base] is the physical address and the value of [Port Name] is the Fibre
Channel card WWN.
Adapter 1: PCI Bus#:0x PCI Device#:0x
Physical address
LPexxxx: I/O Base: 5000
Firmware Version: xxxxxxxx
Port Name: 10000000 C938D229
Node Name: 20000000 C938D229
Topology: Auto Topology: Loop first(Default)
1.Configure Boot Device
2.Configure This Adapter’s Parameters
Fibre Channel card WWN
Enter a Selection:_
Enter <x> to Exit <d> to Default Values <Page Up> to Previous Menu
4
Record the physical address and WWN in the WWN instance management table
for the server (found in "Appendix A WWN Instance Management Table for the
Server (Blank)" (page 30)).
The following shows an example of this.
Host name
IP Address
Physical
slot name
Fibre Channel card
WWN
slot0
10 00 00 00 C9 38 D2 29
Instance
name
Physical
address
Cable tag
5000
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
10
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
■ Details of contents
The details of contents for the WWN instance management table for the server are as
follows:
5
Host name:
Record the host name.
IP address:
Record the IP address of the server.
Physical slot
name:
Record the slot position of installed Fibre Channel card.
For the installation location, refer to the User Guide for each
server.
Fibre Channel
card WWN:
Record the value of [Port Name] or [Adapter Port Name].
Instance name:
Not necessary to record.
Physical
address:
Record the value of [I/O Base] or [I/O Address].
Cable tag:
Record a tag name which indicates the connection path
(relationship between the connected device and the port).
Press the [x] key to exit "LightPulse BIOS Utility".
When installing two or more Fibre Channel cards to the server, first turn off the server, then
repeat Step 1 through Step 4 for each Fibre Channel card to be installed.
If two or more Fibre Channel cards have already been installed in the
server at the time of purchase, the one-to-one relationship between
the WWNs and Fibre Channel cards may not be easy to determine.
The correct WWPNs need to be registered and setup on the
ETERNUS Disk storage system for a server to recognize the
ETERNUS Disk storage system logical disks. If logical volumes are
not recognized by a server, the WWPN maybe registered to an
incorrect CM/CA Port. The WWN field on the WWN Registration
maybe useful in identifying which Fibre Channel card is connected to
which CM/CA Port. For most (but not all) configurations, the WWN
field lists the WWNs of accessible HBAs.
Refer to "ETERNUS Disk storage systems Server Connection Guide
(Fibre Channel) ETERNUS Disk Storage System Settings" for details
about ETERNUS settings.
End of procedure
2.1.2
Installing the Drivers
Refer to the documentation provided with each Fibre Channel card for details on how to obtain
and install a Fibre Channel card driver for it.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
11
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
2.1.3
Checking the Driver Version
Use the Device Manager to check the version of the Fibre Channel card driver.
Procedure
1
In the Device Manager go to [SCSI and RAID controllers], and open the
[Properties] of the Fibre Channel card.
2
Select the [Driver] tab, and open the [Driver Details].
3
Select the driver file, and check its [File version].
For SCSIport Miniport driver: select "lpxnds.sys" for the driver file.
For Storport Miniport driver: select "elxstor.sys" for the driver file.
If a different driver version is displayed from that shown in "Server
Support Matrix", reinstall the driver.
End of procedure
2.1.4
Setting up the Driver Parameters
The procedure varies depending on the product ID of the Fibre Channel card being used.
• For the S26361-F2624-E1, S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/
S26361-F3141-E210, and S26361-F3141-E1 Fibre Channel cards, proceed to "2.1.4.1 For
the S26361-F2624-E1, S26361-F2843-E1/S26361-F2843-E201, S26361-F3141-E10/
S26361-F3141-E210, and S26361-F3141-E1" (page 13).
• For the S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361-F3961-E201,
S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601, and MC-FC82E Fibre
Channel cards, proceed to "2.1.4.2 For the S26361-F3306-E1/S26361-F3306-E201, S26361F3961-E1/S26361-F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306E601, and MC-FC82E" (page 15).
Use the application (HBAnyware, OneCommand Manager, or other) provided by Emulex Corp. to set the driver parameters.
This chapter describes the procedures using HBAnyware.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
12
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
2.1.4.1
For the S26361-F2624-E1, S26361-F2843-E1/S26361-F2843-E201, S26361F3141-E10/S26361-F3141-E210, and S26361-F3141-E1
Set the driver parameters after installing HBAnyware.
Procedure
1
Install HBAnyware.
For installation, refer to the User Guide of S26361-F2624-E1, S26361-F2843-E1/S26361F2843-E201, S26361-F3141-E10/S26361-F3141-E210, or S26361-F3141-E1 Fibre
Channel card.
The Driver Parameter Setting Tool (LightPulse Utility/NT) is included
in HBAnyware.
2
Start up the "LightPulse Utility/NT".
3
Select [Driver Parameters] from [Category:].
4
Select [Registry] with the radio button.
The registry contents are displayed.
The display contents vary according to the installed Fibre Channel
card type and the driver version.
5
Double click the [Device].
The [Modify Registry Entry] dialog box is displayed.
6
Check the current values of each parameter.
Check the value of each parameter in the following tables, and correct the current value if
necessary. If the parameter is not shown, add the necessary information.
- For Windows Server® 2003
Fibre Channel
card
S26361-F3141E1
S26361-F3141E10/S26361F3141-E210
S26361-F2843E1/S26361F2843-E201
Value
Topology
QueueDepth
Queue
Target
ETERNUS2000
- Calculated value
(*1)
0 (FC-AL
Connection)
1 (Fabric
Connection)
ETERNUS4000,
ETERNUS8000
- "255" for
SCSIport Miniport
Driver
- "254" for
Storport Miniport
Driver
1
LinkSpeed
2 (FC-AL Connection,
8Gbps Switch Connection,
4Gbps Switch Connection,
2Gbps Switch Connection)
1 (1Gbps Switch
Connection)
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
13
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
- For Windows® 2000
Fibre Channel
card
S26361-F3141E1
S26361-F3141E10/S26361F3141-E210
S26361-F2843E1/S26361F2843-E201
S26361-F2624E1
*1:
Value
Topology
0 (FC-AL
Connection)
1 (Fabric
Connection)
QueueDepth
Queue
Target
ETERNUS2000
- Calculated value
(*1)
1
ETERNUS4000,
ETERNUS8000
- "255"
LinkSpeed
2 (FC-AL Connection,
8Gbps Switch Connection,
4Gbps Switch Connection,
2Gbps Switch Connection)
1 (1Gbps Switch
Connection)
Use the following formula to calculate the proper setting value:
Value = 40 / (No. of Server-side Fibre Channel ports connected to each ETERNUS-side CA
port) (Round the result down)
Use the value of "8" if the actual result is lower.
If correcting or adding parameters, note the following restrictions.
• Describe each parameter, using ";" (semicolon) to delimit.
• Enter each parameter, using correct spelling. Note that
misspelled words are not checked.
• Do not modify any parameters other than those described here.
The following describes each parameter:
- "Topology" parameter
Set the connection type of the server and ETERNUS Disk storage systems.
- "QueueDepth" parameter
Set the command queue depth.
- "QueueTarget" parameter
Set to specify the command queue depth to either the LUN or to the target.
- "LinkSpeed" parameter
Set the LinkSpeed.
7
After all the cards have been set, select [Exit] from the [File] menu to quit the
"LightPulse Utility/NT".
End of procedure
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
14
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
2.1.4.2
For the S26361-F3306-E1/S26361-F3306-E201, S26361-F3961-E1/S26361F3961-E201, S26361-F3961-E2/S26361-F3961-E202, S26361-F3306-E601,
and MC-FC82E
Set the driver parameters after installing HBAnyware.
When the server OS is Windows Server® 2008 or Windows Server® 2003, it is recommended
that fixed Target IDs be assigned to the Fibre Channel card connected devices, and that automatic Target ID allocation be disabled.
For details of the Target ID settings, refer to the "Fibre Channel Controller User's Guide".
By default, Target IDs are automatically allocated. However, when a device
is added, automatic Target ID allocation can result in a different distribution
of Target IDs, which can cause the devices to not be recognized.
Procedure
1
Install HBAnyware.
For installation, refer to the Fibre Channel card documentation.
2
Start the HBAnyware Utility.
3
Select the target Fibre Channel card and click the [Driver Parameters] tab.
When the same parameter values are to be set for all the Fibre Channel cards (common
setting), select the target server instead of the target Fibre Channel card and click the
[Driver Parameters] tab.
4
Check the parameter values in the [Adapter Parameter] list.
Compare with the parameter values in the following tables, and correct the current value if
necessary.
Select the parameter whose value is to be corrected from the [Adapter Parameter] list and
modify the value in the [Modify Adapter Parameter] area.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
15
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
- For Windows Server® 2008
Fibre Channel
card
S26361-F3961E2/S26361F3961-E202,
S26361-F3961E1/S26361F3961-E201,
S26361-F3306E1/S26361F3306-E201,
S26361-F3306E601, MC-FC82E
Value
Topology
0 (FC-AL
Connection)
1 (Fabric
Connection)
QueueDepth
Queue
Target
LinkSpeed
1
See the Link Speed
settings table (*2),
below
Queue
Target
LinkSpeed
1
See the Link Speed
settings table (*2),
below
Queue
Target
LinkSpeed
1
See the Link Speed
settings table (*2),
below
ETERNUS2000
- Calculated value
(*1)
ETERNUS4000,
ETERNUS8000
- "254"
- For Windows Server® 2003
Fibre Channel
card
S26361-F3961E2/S26361F3961-E202,
S26361-F3961E1/S26361F3961-E201,
S26361-F3306E1/S26361F3306-E201,
S26361-F3306E601, MC-FC82E
Value
Topology
QueueDepth
ETERNUS2000
- Calculated value
(*1)
0 (FC-AL
Connection)
1 (Fabric
Connection)
ETERNUS4000,
ETERNUS8000
- "255" for SCSIport
Miniport Driver
- "254" for Storport
Miniport Driver
- For Windows® 2000
Fibre Channel
card
S26361-F3306E1/S26361F3306-E201
*1:
Value
Topology
0 (FC-AL
Connection)
1 (Fabric
Connection)
QueueDepth
ETERNUS2000
- Calculated value
(*1)
ETERNUS4000,
ETERNUS8000
- "255"
Use the following formula to calculate the proper setting value:
Value = 40 / (No. of Server-side Fibre Channel ports connected to each ETERNUS-side CA
port) (Round the result down)
Use the value of "8" if the actual result is lower.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
16
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
*2:
LinkSpeed settings:
Fabric connection
(Fibre Channel switch connection)
Fibre Channel
card
Maximum Fibre Channel
switch link speed
8Gbps
4Gbps
2Gbps
1Gbps
S26361-F3961E2/S26361F3961-E202,
S26361-F3961E1/S26361F3961-E201,
MC-FC82E
8
4
2
—
S26361-F3306E1/S26361F3306-E201,
S26361-F3306E601
4
4
2
1
FC-AL connection
ETERNUS
2000
ETERNUS4000,
ETERNUS8000
8Gbps
FC-CA
4Gbps
FC-CA
4
8
4
4
4
4
Do not modify any parameters other than those described here.
The following describes each parameter:
- "Topology" parameter
Set the connection type of the server and ETERNUS Disk storage systems.
- "QueueDepth" parameter
Set the command queue depth.
- "QueueTarget" parameter
Set to specify the command queue depth to either the LUN or to the target.
- "LinkSpeed" parameter
Set the LinkSpeed.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
17
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.1 Setup Procedure for non-S26361-F3023-E1 Fibre Channel Cards
5
After the values have been modified, click the [Apply] button.
Values that have been modified but not yet applied are displayed in red in the [Value]
column.
Click the [Apply] button.
6
If there are multiple cards, repeat Step 2 through Step 4 to change the settings
for all cards.
7
After all the cards have been set, select [Exit] from the [File] menu to quit the
"HBAnyware Utility".
End of procedure
2.1.5
Setting Fixed Target IDs (for Windows Server® 2008 and Windows
Server® 2003)
Each device connected to a Fibre Channel card is allocated a Target ID. By default, these Target
IDs are automatically allocated by the driver. This means that, depending on the state of device
recognition, the device Target IDs can and may be reallocated as devices are added and
removed.
If the Target IDs have changed when the server reboots, devices may end up off-line, and
unavailable depending on the OS or application environment being used. Alternatively,
automatic Target ID allocation can be disabled and the Fibre Channel card settings manually
adjusted to assign an arbitrary Target ID to each device connected to the card. It is
recommended that a fixed Target ID be allocated to each device in this way.
Contact your supplier for more details.
2.1.6
Installing the ETERNUS Disk Storage System Driver
Install the driver for ETERNUS Disk storage systems to the server if necessary.
• Refer to "Driver Notes" section in "ETERNUS Disk storage systems Server Connection Guide
(Fibre Channel) for Windows®" for notes on each driver.
This section applies when using path redundancy control (path fail-over) for a multipath
connected ETERNUS Disk storage system or when connecting the ETERNUS Disk storage
system to the server via single-path.
• For details on how to install, uninstall, set up and operate the ETERNUS Disk storage
systems' driver, refer to the Readme file or the User Guide provided with the software.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
18
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.2 Setup Procedure for the S26361-F3023-E1 Fibre Channel Card
2.2
Setup Procedure for the S26361-F3023-E1 Fibre
Channel Card
Install the Fibre Channel cards in the server, and acquire their physical addresses and World
Wide Names (WWNs).
The physical address and WWN of a Fibre Channel card are required information in the following
cases: when an error has occurred in the system, when using the ETERNUS Disk storage systems (security function, host affinity function, etc.) to restrict server access, or when connecting
the ETERNUS Disk storage systems and the server using Fibre Channel switch.
Acquire the physical address and WWN when installing the Fibre Channel card, because they
cannot be determined from BIOS and OS.
Physical address and WWN must be assigned to "WWN instance management table for the
server".
(1) Install the Fibre Channel card
(2) Turn on the server
(3) Acquire the physical address and WWN for the Fibre Channel card
(4) Add a record for the server in the WWN instance management table for the server
(5) Set the Fibre Channel card BIOS
When installing two or more Fibre Channel cards to the server, first turn off the server, then
repeat Steps (1) through (5) above for each Fibre Channel card to be installed.
2.2.1
Installing the Fibre Channel Card
For the installation method, position (PCI bus slots), and notes regarding the Fibre Channel card,
refer to the Fibre Channel card documentation or the User Guide of the server.
Procedure
1
Turn on the server, and press the [Ctrl] + [Q] keys while the following message is
displayed.
QLogic Corporation
QLA23xx PCI Fibre Channel ROM BIOS Version *.**
Copyright(C) QLogic Corporation 2000. All rights reserved
www.qlogic.com
Press <CTRL-Q> for Fast!UTIL
"Fast!UTIL" program starts up (Startup may take longer than usual).
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
19
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.2 Setup Procedure for the S26361-F3023-E1 Fibre Channel Card
2
Check the value of [I/O Address] of the [Select Host Adapter] window.
The value of [I/O Address] is the physical address.
Select Host Adapter
Adapter Type
QLA2xxx
I/O Address
3400
Physical
address
3
Select [Configuration Settings] from [Fast!UTIL Options] menu and press the
[Enter] key.
4
Select [Host Adapter Settings] from [Configuration Settings] menu and press the
[Enter] key.
The [Host Adapter Settings] window appears.
5
Check the value of [Adapter Port Name].
The value of [Adapter Port Name] is the Fibre Channel card WWN.
Host Adapter Settings
BIOS Address
BIOS Revision
Adapter Serial Number
Interrupt Level
Adapter Port Name
Host Adapter BIOS
6
:xxxxx
:x.xx
:xxxxxx
:xx
:200000E08B0214D0
:Disabled
Record the physical address and WWN in the WWN instance management table
for the server (found in "Appendix A WWN Instance Management Table for the
Server (Blank)" (page 30)).
The following shows an example of this.
Host name
Server#1
IP address
192.168.0.10
Physical
slot name
Fibre Channel card
WWN
slot0
20 00 00 E0 8B 02 14 D0
Instance
name
Physical
address
Cable tag
3400
SERV1_SLOT0 to SN200_1_port0
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
20
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.2 Setup Procedure for the S26361-F3023-E1 Fibre Channel Card
7
Set up the Fibre Channel cards BIOS.
Check the values for each parameter in the [Host Adapter Settings] window.
See the following tables and set each value.
For details on how to set the values, refer to BIOS Readme file and Fibre Channel card
user guide.
Parameter
Value
Default
Value
Remarks
BIOS Address
BIOS Revision (*1)
Adapter Serial Number
Fixed for each card
Settings cannot be changed.
Interrupt Level
Adapter Port Name
• Set [Enabled] for SAN
Host Adapter BIOS
Enabled or Disabled
Disabled
Boot.
• Set [Disabled] for non
SAN Boot.
Frame Size
2048
←
5
←
Adapter Hard Loop ID
Disabled
←
Hard Loop ID
Disabled
←
Spinup Delay
Disabled
←
Loop Reset Delay
Connection Options
0 (FC-AL connection)
(*2),
1 (Fabric connection)
(*3)
1
Fibre Channel Tape
Support
Disabled
Enabled
The factory default values
should not need to be
changed.
If the current values are
different, change them back
to the factory default values.
• "0" for an FC-AL
connection
• "1" for a fabric connection
• "1" for an FC-AL
connection
• "1" for a 8Gbps Fibre
Channel switch fabric
connection
Data Rate
0 (1Gbps fixed),
or 1 (2Gbps fixed)
• "1" for a 4Gbps Fibre
2
Channel switch fabric
connection
• "1" for a 2Gbps Fibre
Channel switch fabric
connection
• "0" for a 1Gbps Fibre
Channel switch fabric
connection
*1:
*2:
*3:
8
BIOS version of the Fibre Channel card is displayed.
Check that the BIOS version is the same as shown in "Server Support Matrix".
When connecting directly to the ETERNUS Disk storage systems via a Fibre Channel passthrough blade.
When Fibre Channel Switch is connected to the ETERNUS Disk storage systems via a Fibre
Channel pass-through blade or Fibre Channel switch blade.
Return to the [Configuration Settings] menu by pressing the [Esc] key.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
21
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.2 Setup Procedure for the S26361-F3023-E1 Fibre Channel Card
9
Select [Advanced Adapter Settings] from the [Configuration Settings] menu and
press the [Enter] key.
Check the parameter values in the [Advanced Adapter Settings] window against those in
the following table, and correct the current value if necessary.
.
Value
Default Value
Execution Throttle (*1)
Parameter
16
256
LUNs per Target
256
←
Enable LIP Reset
No
←
Enable LIP Full Login
Yes
←
Enable Target Reset
Yes
←
Login Retry Count
8
←
Port Down Retry Count
45
←
45
←
Disabled
←
RIO Operation Mode
0
←
Interrupt Delay Timer
0
←
Link Down Timeout
Extended Error Logging
*1:
Remarks
The factory default values should
not need to be changed.
If the current values are different,
change them back to the factory
default values.
Set "16" in [Execution Throttle]. This setting allows performance to be increased by tuning the
command queuing function for commands issued to the ETERNUS Disk storage system from
the server. Performance may be degraded if you do not perform this tuning.
10 Press the [Esc] key twice to return to the [Fast!UTIL Options] menu.
If the BIOS settings were changed, save the settings using [Save xxxxxx].
When two or more Fibre Channel cards are installed to the server, select the second or
later Fibre Channel card using the following Steps, and set the BIOS of selected card.
10-1 Select [Select Host Adapter] from the [Fast!UTIL Options] menu and press the [Enter]
key.
10-2 Select the Fibre Channel card to be set (BIOS setting) in [Select Host Adapter] window.
The [Fast!UTIL Option] menu appears. Then perform Step 2 through Step 10.
11 Select [Exit Fast!UTIL] and press the [Enter] key.
12 Select [Reboot System] and press the [Enter] key.
The server reboots.
To return to the [Fast!UTIL] menu, select [Return to Fast!UTIL].
Exit Fast!UTIL
Reboot System
Return to Fast!UTIL
End of procedure
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
22
Copyright 2010 FUJITSU LIMITED
Chapter 2 Setup Procedure for PRIMERGY
>
2.2 Setup Procedure for the S26361-F3023-E1 Fibre Channel Card
2.2.2
Installing the Drivers
Refer to the documentation provided with each Fibre Channel card for details on how to obtain
and install a Fibre Channel card driver for it.
2.2.3
Checking the Driver Version
Use the Device Manager to check the version of the Fibre Channel card driver.
Procedure
1
In the Device Manager go to [SCSI and RAID controllers], and open the
[Properties] of the Fibre Channel card.
2
Select the [Driver] tab, and open the [Driver Details].
3
Select the "ql2300.sys" driver file, and check its [File version].
If a different driver version is displayed from that shown in "Server
Support Matrix", reinstall the driver.
End of procedure
2.2.4
Installing the ETERNUS Disk Storage System Driver
Install the driver for ETERNUS Disk storage systems to the server if necessary.
• Refer to "Driver Notes" section in "ETERNUS Disk storage systems Server Connection Guide
(Fibre Channel) for Windows®" for notes on each driver.
This section applies when using path redundancy control (path fail-over) for a multipath
connected ETERNUS Disk storage system or when connecting the ETERNUS Disk storage
system to the server via single-path.
• For details on how to install, uninstall, set up and operate the ETERNUS Disk storage
systems' driver, refer to the Readme file or the User Guide provided with the software.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
23
Copyright 2010 FUJITSU LIMITED
Chapter 3
3.1
Setup Procedure for PRIMEQUEST
1000 series
Setup Procedure for MC-0JFC11 and MC-0JFC21
Fibre Channel Cards
If a SAN Boot environment is to be set up, the SAN Boot settings
must be made beforehand for the PRIMEQUEST 1000 series. Refer
to "Appendix D Configuration in the SAN Boot Environment" in
"PRIMEQUEST 1000 series INSTALLATION MANUAL" for details.
Install the Fibre Channel cards in the server, and acquire their physical addresses and World
Wide Names (WWNs).
The physical address and WWN of a Fibre Channel card are required information in the following
cases: when an error has occurred in the system, when using the ETERNUS Disk storage systems (security function, host affinity function, etc.) to restrict server access, or when connecting
the ETERNUS Disk storage systems and the server using Fibre Channel switch.
Acquire the physical address and WWN when installing the Fibre Channel card, because they
cannot be determined from BIOS and OS.
Physical address and WWN must be assigned to "WWN instance management table for the
server".
(1) Install the Fibre Channel card
(2) Turn on the server
(3) Acquire the physical address and WWN for the Fibre Channel card
(4) Add a record for the server in the WWN instance management table for the server
When installing two or more Fibre Channel cards to the server, first turn off the server, then
repeat Steps (1) through (4) above for each Fibre Channel card to be installed.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
24
Copyright 2010 FUJITSU LIMITED
Chapter 3 Setup Procedure for PRIMEQUEST 1000 series
>
3.1 Setup Procedure for MC-0JFC11 and MC-0JFC21 Fibre Channel Cards
3.1.1
Installing the Fibre Channel Card
For the installation method, position (PCI bus slots), and notes regarding the Fibre Channel card,
refer to the Fibre Channel card documentation or the User Guide of the server.
Procedure
1
Turn on the server, and press the [Alt] + [E] keys while the following message is
displayed.
!!! Emulex LPexxxx BIOS Copyright xxxx !!! xxxxxxxx
Press <Alt E> to go to Emulex BIOS Utility.
Press <s> to skip Emulex BIOS.
"LightPulse BIOS Utility" starts.
2
Enter the number of the Fibre Channel card to be checked in [Enter a
Selection:_] and press the [Enter] key.
3
Check the [I/O Base] and [Port Name] values.
The value of [I/O Base] is the physical address and the value of [Port Name] is the Fibre
Channel card WWN.
Adapter 1: PCI Bus#:0x PCI Device#:0x
Physical address
LPexxxx: I/O Base: 5000
Firmware Version: xxxxxxxx
Port Name: 10000000 C938D229
Node Name: 20000000 C938D229
Topology: Auto Topology: Loop first(Default)
1.Configure Boot Device
2.Configure This Adapter’s Parameters
Fibre Channel card WWN
Enter a Selection:_
Enter <x> to Exit <d> to Default Values <Page Up> to Previous Menu
4
Record the physical address and WWN in the WWN instance management table
for the server (found in "Appendix A WWN Instance Management Table for the
Server (Blank)" (page 30)).
The following shows an example of this.
Host name
IP Address
Physical
slot name
Fibre Channel card
WWN
slot0
10 00 00 00 C9 38 D2 29
Instance
name
Physical
address
Cable tag
5000
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
25
Copyright 2010 FUJITSU LIMITED
Chapter 3 Setup Procedure for PRIMEQUEST 1000 series
>
3.1 Setup Procedure for MC-0JFC11 and MC-0JFC21 Fibre Channel Cards
■ Details of contents
The details of contents for the WWN instance management table for the server are as
follows:
5
Host name:
Record the host name.
IP address:
Record the IP address of the server.
Physical slot
name:
Record the slot position of installed Fibre Channel card.
For the installation location, refer to the User Guide for each
server.
Fibre Channel
card WWN:
Record the value of [Port Name] or [Adapter Port Name].
Instance name:
Not necessary to record.
Physical
address:
Record the value of [I/O Base] or [I/O Address].
Cable tag:
Record a tag name which indicates the connection path
(relationship between the connected device and the port).
Press the [x] key to exit "LightPulse BIOS Utility".
When installing two or more Fibre Channel cards to the server, first turn off the server, then
repeat Step 1 through Step 4 for each Fibre Channel card to be installed.
If two or more Fibre Channel cards have already been installed in the
server at the time of purchase, the one-to-one relationship between
the WWNs and Fibre Channel cards may not be easy to determine.
The correct WWPNs need to be registered and setup on the
ETERNUS Disk storage system for a server to recognize the
ETERNUS Disk storage system logical disks. If logical volumes are
not recognized by a server, the WWPN maybe registered to an
incorrect CM/CA Port. The WWN field on the WWN Registration
maybe useful in identifying which Fibre Channel card is connected to
which CM/CA Port. For most (but not all) configurations, the WWN
field lists the WWNs of accessible HBAs.
Refer to "ETERNUS Disk storage systems Server Connection Guide
(Fibre Channel) ETERNUS Disk Storage System Settings" for details
about ETERNUS settings.
End of procedure
3.1.2
Installing the Drivers
Refer to the documentation provided with each Fibre Channel card for details on how to obtain
and install a Fibre Channel card driver for it.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
26
Copyright 2010 FUJITSU LIMITED
Chapter 3 Setup Procedure for PRIMEQUEST 1000 series
>
3.1 Setup Procedure for MC-0JFC11 and MC-0JFC21 Fibre Channel Cards
3.1.3
Checking the Driver Version
Use the Device Manager to check the version of the Fibre Channel card driver.
Procedure
1
In the Device Manager go to [SCSI and RAID controllers], and open the
[Properties] of the Fibre Channel card.
2
Select the [Driver] tab, and open the [Driver Details].
3
Select the driver file (elxstor.sys), and check its [File version].
If a different driver version is displayed from that shown in "Server
Support Matrix", reinstall the driver.
End of procedure
3.1.4
Setting up the Driver Parameters
Use the application (OneCommand Manager, or other) provided by Emulex
Corp. to set the driver parameters.
This chapter describes the procedures using OneCommand Manager.
3.1.4.1
For the MC-0JFC11 and MC-0JFC21
Set the driver parameters after installing OneCommand Manager.
When the server OS is Windows Server® 2008 or Windows Server® 2003, it is recommended
that fixed Target IDs be assigned to the Fibre Channel card connected devices, and that automatic Target ID allocation be disabled.
For details of the Target ID settings, refer to the "Fibre Channel Controller User's Guide".
By default, Target IDs are automatically allocated. However, when a device
is added, automatic Target ID allocation can result in a different distribution
of Target IDs, which can cause the devices to not be recognized.
Procedure
1
Install OneCommand Manager.
For installation, refer to the Fibre Channel card documentation.
2
Start the OneCommand Manager.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
27
Copyright 2010 FUJITSU LIMITED
Chapter 3 Setup Procedure for PRIMEQUEST 1000 series
>
3.1 Setup Procedure for MC-0JFC11 and MC-0JFC21 Fibre Channel Cards
3
Select the target Fibre Channel card and click the [Driver Parameters] tab.
When the same parameter values are to be set for all the Fibre Channel cards (common
setting), select the target server instead of the target Fibre Channel card and click the
[Driver Parameters] tab.
4
Check the parameter values in the [Adapter Parameter] list.
Compare with the parameter values in the following tables, and correct the current value if
necessary.
Select the parameter whose value is to be corrected from the [Adapter Parameter] list and
modify the value in the [Modify Adapter Parameter] area.
- For Windows Server® 2008/Windows Server® 2003
Value
Fibre Channel
card
MC-0JFC11,
MC-0JFC21
*1:
*2:
Topology
QueueDepth
Queue
Target
LinkSpeed
1
See the Link Speed
settings table (*2),
below
ETERNUS2000
- Calculated value
(*1)
0 (FC-AL
Connection)
1 (Fabric
Connection)
ETERNUS4000,
ETERNUS8000
- "254"
Use the following formula to calculate the proper setting value:
Value = 40 / (No. of Server-side Fibre Channel ports connected to each ETERNUS-side CA
port) (Round the result down)
Use the value of "8" if the actual result is lower.
LinkSpeed settings:
Fabric connection
(Fibre Channel switch connection)
Fibre Channel
card
Maximum Fibre Channel
switch link speed
8Gbps
4Gbps
2Gbps
1Gbps
8
4
2
—
MC-0JFC11,
MC-0JFC21
FC-AL connection
ETERNUS
2000
4
ETERNUS4000,
ETERNUS8000
8Gbps
FC-CA
4Gbps
FC-CA
8
4
Do not modify any parameters other than those described here.
The following describes each parameter:
- "Topology" parameter
Set the connection type of the server and ETERNUS Disk storage systems.
- "QueueDepth" parameter
Set the command queue depth.
- "QueueTarget" parameter
Set to specify the command queue depth to either the LUN or to the target.
- "LinkSpeed" parameter
Set the LinkSpeed.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
28
Copyright 2010 FUJITSU LIMITED
Chapter 3 Setup Procedure for PRIMEQUEST 1000 series
>
3.1 Setup Procedure for MC-0JFC11 and MC-0JFC21 Fibre Channel Cards
5
After the values have been modified, click the [Apply] button.
Values that have been modified but not yet applied are displayed in red in the [Value]
column.
Click the [Apply] button.
6
If there are multiple cards, repeat Step 2 through Step 4 to change the settings
for all cards.
7
After all the cards have been set, select [Exit] from the [File] menu to quit the
"OneCommand Manager".
End of procedure
3.1.5
Setting Fixed Target IDs (for Windows Server® 2008 and Windows
Server® 2003)
Each device connected to a Fibre Channel card is allocated a Target ID. By default, these Target
IDs are automatically allocated by the driver. This means that, depending on the state of device
recognition, the device Target IDs can and may be reallocated as devices are added and
removed.
If the Target IDs have changed when the server reboots, devices may end up off-line, and
unavailable depending on the OS or application environment being used. Alternatively,
automatic Target ID allocation can be disabled and the Fibre Channel card settings manually
adjusted to assign an arbitrary Target ID to each device connected to the card. It is
recommended that a fixed Target ID be allocated to each device in this way.
Contact your supplier for more details.
3.1.6
Installing the ETERNUS Disk Storage System Driver
Install the driver for ETERNUS Disk storage systems to the server if necessary.
• Refer to "Driver Notes" section in "ETERNUS Disk storage systems Server Connection Guide
(Fibre Channel) for Windows®" for notes on each driver.
This section applies when using path redundancy control (path fail-over) for a multipath
connected ETERNUS Disk storage system or when connecting the ETERNUS Disk storage
system to the server via single-path.
• For details on how to install, uninstall, set up and operate the ETERNUS Disk storage
systems' driver, refer to the Readme file or the User Guide provided with the software.
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
29
Copyright 2010 FUJITSU LIMITED
Appendix A WWN Instance Management Table for
the Server (Blank)
This table is used in "2.1.1 Installing the Fibre Channel Card" (page 10), "2.2.1 Installing the
Fibre Channel Card" (page 19), and "3.1.1 Installing the Fibre Channel Card" (page 25), and
should be used as necessary.
WWN instance management table for the server
Host name
IP Address
Physical
slot name
Fibre Channel card
WWN
Instance
name
Physical
address
Cable tag
P3AM-2932-05ENZ0 ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for Windows®
30
Copyright 2010 FUJITSU LIMITED
ETERNUS Disk storage systems
Server Connection Guide (Fibre Channel) for Windows®
Driver Settings for PRIMERGY/PRIMEQUEST 1000 Series
P3AM-2932-05ENZ0
Date of issuance: April 2010
Issuance responsibility: FUJITSU LIMITED
•
The contents of this manual are liable to being updated without notice.
•
While the contents of this manual are the product of all due care and diligence, no
responsibility can be accepted for operational problems arising from any errors or
missing information, or other use of the information contained in this manual.
•
Fujitsu assumes no liability for damages to third party copyrights or other rights arising