operator interfaces - Steven Engineering

operator interfaces - Steven Engineering
K
Touchscreen Displays
• SmartTouch Family
12.1” HG4F, 10.4” HG3F
& 5.7” HG2F. . . . . . . . . . . . . . . . . K-3
• Programming . . . . . . . . . . . . . . . . . K-6
• 4” HG1B Series . . . . . . . . . . . . . . K-16
Character Displays
• HG1X Family
2, 4 & 8 Line . . . . . . . . . . . . . . . . K-19
• Programming . . . . . . . . . . . . . . . . K-20
Operator Interfaces
Section
Selection Guide..................................K-2
for more information on this product family visit
www.idec.com/oi
www.idec.com/oi
Additional Web Resources
• New and updated product information
• Downloadable software demos & upgrades
• Part configuration tool & cross reference
• Online stock check & ordering
• IDEC field sales & distributor search
• Online literature request
• Downloadable manuals & CAD drawings
• Manufacturer’s suggested retail price list
• Product training schedule & locations
• Advertising & trade show schedules
• Press releases & FAQs
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
Selection Guide
Selection Guide
Series
Appearance
Description
Page
SmartTouch
Family
12.1” HG4F, 10.4” HG3F and
5.7” HG2F touchscreens that
function as either a stand
alone or communicate with
IDEC and other manufacturers’ PLCs
K-3
HG1B
4” monochrome LCD
touchscreen for small
applications.
K-16
HG1X
Text message display with
LCD screen.
K-19
WindO/I-NV2
Programming tool for all IDEC
touchscreens (HG4F/3F/2F
and HG1B).
K-6
WindMSG
Programming Software for
Character displays (HG1X)
K-20
Touchscreens
Character Displays
Programming
Software
Operator Interfaces
K
K-2
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
IDEC Touchscreen Displays
IDEC SmartTouch
Family:
Smart design to fit your needs
From the large 12.1” TFT LCD
Screen, to the compact 5.7” STN
LCD, our screens support 256 colors
with high pixel resolution to give you
sharp images and excellent visibility. In keepingl with IDEC’s attention
to detail, our slim-body design
adapts to applications where space
is limited. With up to 8MB of memory and a 200MHz 32-bit RISC CPU,
IDEC Touchscreens put control,
power and speed at your fingertips.
Programming power
made easy
IDEC’s powerful WindO/I-NV2 software lets you create colorful graphical interfaces for easier production
supervision and control. A built-in
library of over 5000 bitmap images
helps you easily display almost
every manufacturing activity you
want to control. Our programming
software is intuitive and userfriendly. With re-sizeable pop-up
screens, Windows compatible fonts,
and multilingual text capabilities,
you enjoy the utmost flexibility in
designing and programming.
www.idec.com
12.1” HG4F
K
Operator Interfaces
Versatile, High functionality
IDEC Touchscreens can function as
either a stand alone controller or
communicate with IDEC PLCs and a
wide array of major manufacturers’
PLCs. Touchscreens interface with
any of your equipment to provide
graphical data presentations in vivid
color and to display bar graphs and
meters to represent analog data.
Illuminated pushbuttons can
replace physical mechanical
switches; pilot lamps can display
on/off states and show almost any
production information you need
to monitor.
10.4” HG3F
5.7” HG2F
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-3
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Features
The IDEC SmartTouch Family is ideally matched to today’s
sophisticated technology. Using a wide range of graphic
options, you can clearly represent specific equipment, make
production information immediately apparent and instantly display safety problems. Consolidating controls on an IDEC touchscreen interface eliminates costly investments in wiring and
installation of multiple pushbutton indicators on the traditional
control panel. Just think how you can benefit with touchscreens at critical spots in your plant
Expansion I/O
An expansion digital I/O module
gives you the option of expanding your system with 16 DC
inputs and 16 transistor outputs
for basic PLC control.
Basic Data Representation
A built-in software library of
over 5000 bit-mapped images lets you graphically represent
almost any plant activity or equipment that you want to monitor or control. In addition to representing meters, bar graphs and
switches, you can also incorporate keypads to facilitate changing values. Our user-friendly programming software lets you design
each screen by simply selecting objects from a pull-down menu or from a row of object icons and dropping it onto the screen work
area. All bitmap images are available in 256 colors and are easily re-configurable.
Ethernet Support
Remote Network
Local Area Network
Operator Interfaces
K
Ethernet
The built-in 10BaseT Ethernet port found on the 10.4” and 12.1” touchscreens allow you to remotely monitor machine-operating status via the Internet or your Local Area Network using any web browser. Regardless of your location, you can use your PC’s browser
(Netscape or Internet Explorer) to collect CF Card data about any touchscreen project. You can efficiently monitor and manage production activity from your office without the time or expense of travel.
Recipe, Alarm and Trend Logging
Compact Flash Card
The Recipe function allows you to conveniently
set operational parameters, which can be individually defined
for different processes. The Alarm function stores historical
events with a date and time stamp. Trend Logging expresses
data in graphical form according to the time period you define.
Using these functions, you can quickly view production information and collect and manage valuable data.
K-4
www.idec.com
IDEC SmartTouch support Compact Flash (CF) Cards with up to
512 MB of memory. In addition to storing recipe, alarm and
trending data, the CF Card can also store screen captures in a
BMP format for documentation purposes. The CF Card can hold
one or more projects and you can easily transfer a project
directly to another touchscreen by simply inserting the card
into the second touchscreen and downloading what you need.
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Features con’t
To meet your application needs,
IDEC offers a 12.1” and 10.4” TFT
LCD screen and 5.7” STN LCD
screen which all come with 256
color or monochrome with 16
shades of gray to provide you with
either multicolored or gray scale
graphics. All screens have high
pixel resolution and super bright
LCD screens with 350 cd/m2 for
the 12.1” and 10.4” screen and 250 cd/m2 for the 5.7” screen to
provide sharp quality images. With RS-232 / RS-485 / RS-422
communication, all IDEC Touchscreens communicate with IDEC as well as other industry leading PLC manufacturers.
Their slim body style of: 50mm depth for the 5.7”
HG2F, 49.6mm depth for the 10.4” HG3F, and
52.1mm depth for the 12.1” HG4F, provide a great
advantage in space and cost saving in a panel.
one cable is needed to program both units. The Pass Thru
communications function is applicable to the following PLCs:
IDEC Micro3, Micro3C, OpenNet Controller, MicroSmart and
Mitsubishi MELSEC-FX, FX3UC and Q.
Support of Leading Manufacturer’s PLCs
IDEC Touchscreen’s communications capabilities expand well
beyond IDEC brand PLCs. Other major PLC manufacturers supported are: Allen Bradley, Mitsubishi, Omron, Automation
Direct (Koyo), Keyence, GE, Modicon, Siemens, Sharp, Hitachi,
Schneider, Yaskawa, Fanuc, Matsushita Electric Works (Aromat) and Yokogawa.
Approvals and International Ratings
The IDEC SmartTouch Family is UL listed for use in hazardous
locations (Class I Div. 2). In addition the 5.7” screen is IP65 and
Nema 13 rated, while the 10.4” and 12.1” screens are IP66,
Nema 4, 4X, 13 rated so they can be used in the most demanding industrial applications.
Printer Function
O/I Link Communication
1:N PLC Communication
This mode allows a single IDEC touchscreen to communicate
with multiple PLCs. It is used when you need only one centrally
located touchscreen to monitor and control PLCs in different
locations. Depending on PLC type, a maximum of 31 PLCs can
be connected to one touchscreen. PLC manufacturers supported for 1:N communication are: IDEC OpenNet Controller
and MicroSmart, Automation Direct (Koyo): DirectLogicDL205/405 and Modicon: Modbus RTU.
K
Operator Interfaces
This link permits a single PLC to communicate with multiple
IDEC touchscreens, where one touchscreen serves as the
master and up to 15 as slaves. An O/I Link will accommodate
communications over a maximum distance of 200 meters. The
O/I Link should be used whenever you are using more than
one touchscreen in a location to monitor and control a single
PLC.
You can use this capability to print alarm data so a hard-copy
record of specific events can be maintained. Copies of
screens can also be printed when needed for documentation.
Serial printers supported on all IDEC SmartTouch Screens.
Parallel Printers supported on 10.4” and 12.1” Models only.
Barcode Reader Support
IDEC Touchscreens provide a serial
port that you can configure for use
by special communication devices
such as barcode readers. A barcode reader can send data directly
to the touchscreen, where it can be
used for quick viewing before being
transferred to the PLC for further
data manipulation.
Debugging Functions
Two modes are available for either monitoring data or troubleshooting. Once you download the project you created in
WindO/I-NV2 to the touchscreen, you can use the Debugging
Mode to communicate directly with the touchscreen and
switch between screens or view and modify batch data from
the controls of your PC. In Simulation Mode, you can use simple On/Off control without connecting to the PLC.
Pass Thru Function
This function lets you download a PLC program from a PC
through the touchscreen without interrupting operations. Only
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-5
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
WindO/I-NV2 Software
Easy Programming: Intuitive Drag & Drop
Functionality
The WindO/I-NV2 software for all IDEC SmartTouch
touchscreens is the programming tool that lets you
create colorful graphical interfaces to visualize
operating conditions. The software is very intuitive
with drag and drop functionality. The Help menus are
a great source of information and a built-in library of
bitmaps provides over 5000 images to help expand
your creativity. The software also includes a debug
function where you can go online with the touchscreen for monitoring and changing data.
Flexible Screen Display for Efficient Editing
With WindO/I-NV2 software, screens can be easily
arranged. A total of 3000 base screens can be created (as allowed by the memory size). Sub-screens
known as pop-up menus can be resized, made
(showing backgrounds) using the superimpose function, and can be made to appear anywhere around
the base screen.
Operator Interfaces
K
Easy to manage Projects and Screens
Screens and Project Settings List:
• Screens can be duplicated and their properties can
be changed easily.
• Project settings can be edited.
• Devices, text, and images can be imported
or exported.
Screen Preview List:
• Screens can easily be selected using the
preview image function.
Object List:
• Each object displays its properties such as the type
of device used, conditions, and operations.
Buttons:
• A button selected from an object list is shown on
the editing screen.
Extensive Image Library
A built-in symbol library provides over 5000 symbols
to help you create cutting-edge graphical screens.
Image data from BMP, JPG, DXF, WMF, and ICO files
can also be imported.
K-6
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
WindO/I-NV2 con’t
Compatible with Standard Windows Fonts
Multilingual Capabilities for Global Applications
Fonts used in Windows can be used on the IDEC SmartTouch
touchscreens, making it possible to choose from a variety of
text styles.
The IDEC SmartTouch Touchscreen family can support other
languages. With the text group function you can create a text
database in different languages. Once the touchscreen is in a
different country(e.g. China or Mexico) the customer can easily
switch all text messages from English to Chinese or Spanish by
a touch of a button.
Easy Programming of Operating Conditions
Operating conditions for objects such as switches, lamps, bit/
word write, screen switching, and many more are easy to use.
Step by step wizards guide the user through the set-up process.
Applicable languages:
Win2000 and XP make it possible to input Japanese, Simplified
Chinese, Traditional Chinese, and Korean languages, Western
European languages (English, German, French, Italian, Spanish,
Dutch, Norwegian, Danish, Finnish, Swedish, etc.) Central European languages (Czech, Hungarian, Romanian, Croatian, Slovene, Polish, and Slavic), Baltic languages, Cyrillic languages
(Russian, Ukranian, Bulgarian, Macedonian).
Script Function
K
Operator Interfaces
Users with basic programming knowledge in “C” can combine
conditional statements, mathematical operations, and other
functions to create simple and complex processes, greatly
reducing the programming required in the PLC. A syntax check
function is also available to provide easy program troubleshooting.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-7
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Available Functions
Item
Category
Communication
PLC link communication
DM link communication
O/I link communication
Ethernet
No host
User Memory
Interface
Display Color
Brightness
Resolution
Touch Switch
CC Switch
Expansion Unit
Features
Available Functions
Functions
Operator Interfaces
K
Parts
WindO/I-NV2
Functions
RS232C/RS485 (422)
Ethernet
CF card slot
Parallel
256 colors
Monochrome
HG2F
Touch Switch Type
CC Switch Type
HG3F
HG4F
✓
✓
✓
—
✓
✓
✓
✓
—
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
2 MB
2 MB
8 MB*
8 MB*
✓
—
✓
—
✓
✓
✓
—
✓
—
✓
✓
✓
✓
✓
✓
✓
—
✓
✓
✓
✓
✓
—
(cd/m2)
250
250
350
350
(pixels)
320 × 240
320 × 160**
640 × 480
800 × 600
16 × 12
16 × 8
32 × 24
40 × 30
—
4 × 1 row (bottom)
—
—
Digital I/O unit
✓
✓
✓
✓
System program download
Font download
Download via Ethernet
Download via O/I link
Project transfer via CF card
Printer output
Backlight replacement
Environment resistance
Simulation
Pass through
Device monitor
Web server function
Overlapped screens
Sub-screen superimpose
Text group switching
Script
Part operating condition setting
Alarm log
Logging
Recipe
Password setting
Bit button
Word button
Goto screen button
Print button
Key button
Keypad
Selector switch
Potentiometer
Numerical input
Character input
Pilot lamp
Picture display
Message display
Message switching display
Alarm list display
Alarm log display
Numerical display
Bar graph
Trend chart
Pie chart
Meter
Calendar
Bit write command
Word write command
Goto screen command
Timer
Print command
Screen print command
Debugging
Log data upload tool
Graphic library tool
Screen import
Text browser
Device browser
Script browser
Picture browser
Basic/advanced mode
Preview
Windows font
Library function
Global replace
Work space
✓
✓
—
✓
✓
✓
✓
✓
✓
✓
✓
—
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
—
✓
✓
✓
✓
✓
✓
✓
✓
—
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
1. *2MB used for OS
2. **four tactile push regions (40 x 70 pixels)
K-8
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Part Numbers
Part Numbers: IDEC SmartTouch
Part Numbers
12.1"
10.4"
5.7”
5.7” with
CC Click
Bezel Color
Description
HG4F-JT22TFW
Light Gray
Color TFT LCD Touchscreen
HG4F-JT22TFB
Black*
Color TFT LCD Touchscreen
HG4F-JT22TFW-DH485-500
Light Gray
Color TFT LCD Touchscreen with DF1 / DH485 converter/cable package for SLC 500
(w/RJ45 connector)
HG3F-FT22TFW
Light Gray
Color TFT LCD Touchscreen
HG3F-FT22TFB
Black*
Color TFT LCD Touchscreen
HG3F-FT22TFW-DH485-500
Light Gray
Color TFT LCD Touchscreen with DF1/DH485 converter/cable package for SLC 500
(w/RJ45 connector)
HG2F-SS22VCF
Light Gray
Color STN LCD Touchscreen
HG2F-SB22VCF
Light Gray
Monochrome STN LCD Touchscreen
HG2F-SS22VCF-DH485-500
Light Gray
Color STN LCD Display with DF1 / DH485 converter/ cable package for SLC500 (w/
RJ45 connector)
HG2F-SB22VCF-DH485-500
Light Gray
Monochrome STN Color Display with DF1 / DH485 converter / cable package for
SLC500 (w/RJ45 connector)
HG2F-SS52VCF
Light Gray
Color STN LCD Touchscreen w/ CC Click Tactile Touchbutton Technology
HG2F-SB52VCF
Light Gray
Monochrome STN LCD Touchscreen w/ CC Click Tactile Touchbutton Technology
* Black Bezel Models available upon request. Please consult IDEC.
Accessories
Part Numbers: Accessories
Accessory
Programming Tools
Protective Sheet
Mounting Clips
Replacement Backlight
O/I Link Unit
32 Point Digital I/O
Compact Flash Card
www.idec.com
Part Number
WindO/I-NV2 Programming software for all IDEC Touchscreen Series
HG9Y-ZSS2W
Cable connecting PC to Touchscreen via RS-232 Serial Port
HG9Z-XCM1A
USB to RS-232 Convertor for PCs without Serial Ports
FC4A-USB
AB SLC500 (w/RJ45 connector) DF1 / DH485 Communication Package
HG9Z-GWDF1DH485-2
For 12.1” HG4F (2 pcs. / pack)
HG9Z-4DAPN02
For 10.4” HG3F (2 pcs. / pack)
HG9Z-3DAPN02
For 5.7”HG2F (5 pcs. / pack)
HG9Z-2D2
For 10.4” HG3F & 12.1” HG4F (10 pcs. / pack)
HG9Z-4K1PN10
For 5.7” HG2F (4 pcs. / pack)
HG9Z-2K1PN04
For 12.1” HG4F
HG9Z-4FB
For 10.4” HG3F
HG9Z-3FB
For 5.7” HG2F
HG9Z-2B1
For 12.1” HG4F / 10.4” HG3F / 5.7” HG2F
HG9Z-2G1
For 10.4” HG3F & 12.1” HG4F (16 Inputs & 16 Outputs)
HG9Z-3P102
For 5.7” HG2F (16 Inputs & 16 Outputs)
HG9Z-2P101
32MB CF Card for 5.7” HG2F, 10.4” HG3F, 12.1” HG4F
HG9Z-MF32
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K
Operator Interfaces
Converters
Description
K-9
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Part Numbers con’t
Part Numbers: Cables
Series
Manufacturer
Applicable CPU
Communication Type
FA-3S
PF3S-CP11/CP11T
IDEC
FA-2J
PF2J
Micro3
FC2A
Micro3C
FC2A-...C
OpenNet
FC3A
N/A
PF3S-SIF2
N/A
RS485
PF3S-SIF4
N/A
RS232
PF2-CLA
N/A
RS485
Built-in Port
HG9Z-3C115A
RS232
Built-in Port
HG9Z-3C125A
RS485
Built-in Port
HG9Z-2C145A
RS232
Built-in Port
HG9Z-3C125A
RS485
Built-in Port
HG9Z-2C145A
RS232
MicroSmart
FC4A
RS485
RS232
PLC-5
1785
RS422
RS232
Built-in Port
FC4A-PC1/HPC1
Operator Interfaces
K
Automation
Direct (Koyo)
1747-L53, 1747-L54
MicroLogix 1000,
1200, 1500
1761, 1762
DL405
HG9Z-3C115A
FC4A-PC3/HPC3
HG9Z-2C145A
Built-in Port
1770-KF2
Built-in Port
1770-KF2
N/A
HG9Z-2C125A
DH485
Built-in Port
please purchase
IDEC converter:
HG9ZGWDF1DH485-2
(DF1-DH485 converter)
RS232
Built-in Port
HG9Z-2C135A
Built-in Port
D4-DCM
N/A
RS422
Built-in Port
N/A
DL205
D2-240
RS232
Built-in Port
N/A
S7-200
CPU 212, 214, 215, 216, 221, 222, 224,
226, 226XM, 224XP
RS485
Built-in Port
HG9Z-2C155
RS232
CPU 313, 314, 315, 315-2DP, 316, 318
CP-340-RS232C or
CP-341-RS232C
N/A
S7-300
Siemens
RS485
S7-400
Schneider (Telemecanique,
SquareD)
N/A
Built-in Port
RS232
D4-430, D4-440
FC4A-KC2CA
FC4A-PC2/HPC2
Allen Bradley
SLC-5/03, SLC-5/04,
SLC-5/05
Comm. Cable P/N
PF2-CLA
RS232
PF3S-CP12/CP13
Communication
Module Required
CPU 412, 414, 416, 416F-2, 417
TWDLCAA16DRF, TWDLCAA24DRF
(including 10, 20, 40 CPUs)
Twido
Momentum
171CCC96020
CP-340-RS 422/485 or
CP-340-RS 422/485
CP-440-RS 422/485 or
CP-440-RS 422/485
N/A
RS232
CP-440-RS232C or
CP-441-RS232C
N/A
RS232
TWDNAC232D
N/A
TWDNAC485D
HG9Z-3C115A
TWDNAC485T
HG9Z-2C145A
Built-in RJ-45 Port
CAT 5 Ethernet
Crossover cable
RS485
RJ-45 Ethernet Port
N/A = Cable not available at this time. Wiring diagram available at www.idec.com/usa/smarttouch. Select the link for “Supported PLCs”.
K-10
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
Manufacturer
Others
Series
Others
Applicable CPU
SmartTouch Family
Communication Type
RJ45 Ethernet Port
Built-in RJ45 Port
Cat 5 Ethernet
Crossover Cable
FP0
RS232
Built-in-Port
HG9Z-2C165A
Built-in-Port
N/A
RS232
RS422
FP
Comm. Cable P/N
Any PLCs that support MODBUS/TCP
protocol
FP1
Aromat
Communication
Module Required
FP Sigma
Built-in-Port
HG9Z-2C165A
FPG-COM1 (AFPG801)
N/A
FPG-COM2 (AFPG802)
N/A
RS485
FPG-COM3 (AFPG803)
N/A
Built-in-Port
RS232
FP2, FP2SH
Built-in-Port
N/A
RS232
AJ71C24-S3/S6/S8 or
AJ71UC24
RS485
AJ71C24-S3/S6/S8 or
AJ71UC24
RS485
A1SJ71C24-R2/R4 or
A1SJ71UC24-R2/R4
RS232
A1SJ71C24-R2/R4 or
A1SJ71UC24-R2/R4
RS232
Built-in-Port
RS232
A0J2-C214-S1
RS485
A0J2-C214-S1
RS485
1J71C24-S6/S8 or
AJ71UC24
N/A
RS232
1J71C24-S6/S8 or
AJ71UC24
HG9Z-3C135A
RS232
A1SJ71C24-R2/R4 or
A1SJ71UC24-R2/R4
HG9Z-3C145A
RS485
A1SJ71C24-R2/R4 or
A1SJ71UC24-R2/R4
N/A
RS422
Built-in-Port
HG9Z-3C165A
RS232
Built-in-Port
N/A
RS232
Built-in-Port
HG9Z-3C145A
RS485
Built-in-Port
N/A
A1SH
MELSEC-A
AFP3462
AFP3462
A1N, A2N, A3N
A0J2, A0J2H
N/A
N/A
RS232
FP10, FP10SH
A2CCPUC24
AFP8550
Built-in-Port
A2A, A3A, A2U, A3U, A4U
Mitsubishi
A2US, A2USH-S1
HG9Z-3C135A
N/A
HG9Z-3C145A
HG9Z-3C135A
K
Operator Interfaces
A2N
A1SJH, A1SH, A2SH, A2C, A0J2H
A2A, A3A, A2US, A2USH
A2U, A2USH-S1
Q00CPU, Q01CPU
Q02CPU
MELSEC-Q
C01CPU-A
Q02CPU, Q06HCPU, Q12PHCPU
N/A = Cable not available at this time. Wiring diagram available in WindO/I-nv2 manual. Visit www.idec.com/manuals. Download Host Interface manual & select “Connection to a PLC” Chapter 2.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-11
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Series
Manufacturer
Applicable CPU
Communication Type
Communication
Module Required
Comm. Cable P/N
FX0, FX0N, FX0S, FX1, FX1S, FX2, FX2C
FX1N, FX1NC, FX2N, FX2NC
RS422
Built-in-Port
RS422
FX2N-422-BD
RS485
FX2N-485-BD
RS232
FX2N-232-BD
RS232
FX1N-232-BD
RS422
FX1N-422-BD
HG9Z-3C165A
RS485
FX2N-485-BD
N/A
RS232
CPM1-CIF01
HG9Z-3C155A
RS422
CPM1-CIF11
FX3UC
Mitsubishi con’t
MELSEC-FX
FX2N
FX1N
CP1, CPM1A
CPM2A
RS232
Built-in-Port
CPM1-CIF01
HG9Z-3C165A
N/A
N/A
N/A
N/A
HG9Z-3C155A
C120-LK201-V1
RS232
C120-LK202-V1
RS422
Omron
RS422
C1000HF
C200HS
C500-LK203
C200H-LK201
C200HE, C200HG, C200HX
Operator Interfaces
RS232
CS1
Keyence
C500-LK203
RS232
RS422
C120, C120F
C500-LK201-V1
RS232
RS422
K
C200H-LK202
N/A
N/A
HG9Z-3C135A
N/A
N/A
C200HW-COM03/06
N/A
C200H-LK201
HG9Z-3C135A
C200HW-COM02/040/5/06
N/A
RS232
C120-LK201-V1
HG9Z-3C135A
RS422
C120-LK202-V1
N/A
RS232
Built-in-Port
HG9Z-3C155A
C200HE-CPU42, C200HG-CPU43/63,
C200HX-CPU44/64
RS232
Built-in-Port
RS232
Built-in-Port
N/A
CS1W-SCB41 (port1)
RS422
CS1W-SCB41 (port2)
N/A
RS232
Built-in-Port
N/A
N/A
KV Series
KV 10, 16, 24, 40, 80
KV-700
KV-700
VersaMax Nano/
Micro
10 I/Os, 14 I/Os
RS232
Built-in-Port
23 I/Os, 28 I/Os
RS485
Built-in-Port
CPU 311, 313, 323, 331, 341, 350, 351,
352, 360, 363, 364, 374
RS485
Built-in-Port
CPU 331, 341, 350, 351, 352, 360, 363,
364, 374
RS232
Series 90-30
N/A
CQM1H, C200HSCPU21/23/31/33
CS1G, CS1H
GE Fanuc
HG9Z-3C135A
C500-LK203
C500, C500F, C1000H, C2000, C2000H
SYSMAC-C
C500-LK201-V1
RS485
IC693CMM311
N/A
N/A
N/A
N/A = Cable not available at this time. Wiring diagram available in WindO/I-nv2 manual. Visit www.idec.com/manuals. Download Host Interface manual & select “Connection to a PLC” Chapter 2.
K-12
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Specifications
Type
Rated Power Voltage
Power Voltage Range
Power Consumption
Power Inrush Current
Allowable Momentary Power Interruption
General Specifications
Dielectric Strength
Insulation Resistance
Operating Temperature
Operating Humidity
Storage Temperature
Storage Humidity
Pollution Degree
Corrosion Immunity
Vibration Resistance (damage limits)
Shock Resistance (damage limits)
Noise Immunity
Operation Specifications
Electrostatic Discharge
Mounting
Degree of Protection
Dimensions (mm)
Weight (approx.)
HG2F
HG3F
HG4F
Touch Screen Type
CC Switch Type
Resistive membrane
16 x 12
16 x 8
32 x 24
40 x 30
4
x
1
row
—
—
—
(bottom only)
0.2 to 0.8N
2.5 to 5.0N
0.2 to 0.8N
0.2 to 0.8N
1,000,000 operations
Electronic buzzer
Possible to press two switching areas simultaneously (CC switch and touch screen cannot be
pressed together)
Type
Switching Element
Resolution
CC Switch Quantity
Operating Force
Mechanical Life
Acknowledge Sound
Multiple Operations
HG2F
LCD
Effective Display Area (mm)
Display Resolution
LCD Life
Contrast Adjustment
Backlight
Backlight Life
Backlight Control
Backlight Replacement
1/4 size
Quantity of Characters
(CC Switch Type)
Character Magnification
Character Attribute
Graphics Type
Window Display
1/2 size
Full size
Double size
1/4 size
1/2 size
Full size
Double size
HG3F
Color
K
HG4F
Color
Color
Monochrome
Color STN
Monochrome STN
Color TFT
118.2W x 89.4H
211.2W x 158.4H
246W x 184.5H
320W x 240H pixels
640W x 480H pixels
800W x 600H pixels
50,000 hours minimum
100,000 hours minimum
60,000 hours minimum
Possible in steps using the front touch screen
Cold-cathode tube
Cold-cathode tube (2 tubes)
40,000 hours nominal (Note)
50,000 hours nominal (Note)
Automatic OFF
Possible
8 x 8 pixels (Western European language: ISO 8859-1, Central European language: ANSI 1250,
Japanese katakana and symbols: JIS 8-bit code)
8 x 16 pixels (Western European language ISO 8859-1, Central European language: ANSI 1250,
Japanese katakana and symbols: JIS 8-bit code)
16 x 32 pixels, 24 x 48 pixels, 32 x 64 pixels (Western European language: ISO 8859-1)
16 x 16 pixels (Japanese JIS first and second level characters, simplified Chinese, traditional Chinese, Korean)
32 x 32 pixels (Japanese JIS first level characters, Mincho font)
40 characters x 30 lines (40 x 20)
80 characters x 60 lines
100 characters x 75 lines
40 characters x 15 lines (40 x 10)
80 characters x 30 lines
100 characters x 37 lines
20 characters x 15 lines (20 x 10)
40 characters x 30 lines
50 characters x 37 lines
10 characters x 7 lines (10 x 5)
20 characters x 15 lines
25 characters x 18 lines
0.5, 1, 2, 3, 4, and 8 vertically and horizontally
Blink (1 or 0.5 sec period), reverse, bold, shadowed
Straight line, polyline, polygon, rectangle, circle, ellipse, arc, pie, equilateral polygons (3, 4, 5, 6, 8), paint, bitmap image
3 popup screens + 1 system screen
Operator Interfaces
Display Specifications
Type
Display Character Size
HG2F
HG3F
HG4F
24V DC
20.4 to 28.8V DC
19.2 to 28.8V DC
10W maximum
25W maximum
20A maximum
15A maximum (cold start)
10 ms minimum
1,000V AC, 10 mA, 1 minute between
1,500V AC, 10 mA, 1 minute between power and FG terminals
power and FG terminals
50 MΩ minimum between power
10 MΩ minimum between power and FG terminals (500V DC megger)
and FG terminals (500V DC megger)
0 to 50°C (no freezing)
0 to 45°C (no freezing)
10 to 95% RH (no condensation)
20 to 85% RH (no condensation)
–20 to +60°C (no freezing)
10 to 95% RH (no condensation)
20 to 85% RH (no condensation)
2 (IEC 60664-1)
Atmosphere free from corrosive gases
10 to 20 Hz amplitude 0.625 mm, 20 to 55 Hz acceleration 9.8 m/s2
2 hours per axis on each of three mutually perpendicular axes
147 m/s2, 11 ms, 5 shocks on each of three mutually perpendicular axes
Fast transient/burst test, common mode: Level 3, power terminals: ±2 kV, communication line: ±1 kV
(IEC/EN 61000-4-4)
ESD-3 (RH-1), Level 3, (contact ±6 kV, aerial ±8 kV) (IEC/EN 61000-4-2)
Panel mounting
IP65 NEMA TYPE 13 (operator)
IP66 NEMA TYPE 4, 4X, 13 (operator)
172W x 136H x 56D
324W x 240H x 55.8D
348W x 270H x 58.1D
800g
2800g
3400g
The backlight life refers to the time until the surface brightness reduces
to a half after using continuously at room temperatures.
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-13
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Specifications con’t
Operation Specifications
Print Function
(support)
SII printer,
DPU-414
Power Failure
Backup
Backup data: Calendar, log data, keep internal relay, keep
internal register
Backup duration: 1 month (at 25°C) after full charging for
two days
Parts
ESC/P, PC-PR, PCL command;
EPSON PX-V600/Stylus C84
*2MB for OS
Synchronization
Communication
Method
Control System
Connector
Applicable Quantity
Mounting Style
Input Points
Rated Voltage
Isolation Method
Output Points
Load Voltage
Isolation Method
Output Signal
Output ON Voltage
Output Current
Connector
CF Card Interface Specifications
Compact Flash Type I standard compliant
Maintenance
Communication
Interface Specifications
Connector
RS485 (422)
Calendar
2 MB
8 MB*
Bit Button, Word Button, Goto Screen Button, Print Button,
Key Button, Keypad, Selector Switch, Potentiometer,
Numerical Input, Character Input, Pilot Lamp, Picture Display, Message Display, Message Switching Display, Alarm
List Display, Alarm Log Display, Numerical Display, Bar
Graph, Trend Chart, Pie Chart, Meter, Calendar, Bit Write
Command, Word Write Command, Goto Screen Command,
Timer, Print Command, Screen print
Year, Month, Day, Hour, Min., Sec., Day of Week
±30 sec per month (at 25°C)
Transmission Speed
Input
Base screen: 3000 max., popup screen: 3015 max.
Expansion Unit (Digital I/O Unit)
Screen Types
No. of Screens
User Memory
Electrical
Characteristics
HG2F
HG3F/4F
Base screen, popup screen, system screen
Output
Type
50-pin compact flash card connector
Memory size supports up to 512MB.
Parallel Interface Specifications (HG3F/4F)
D-sub 25-pin female connector
Ethernet Specifications (HG3F/4F)
Interface Specifications
IEEE 802.3 standard compliant, 10Base-T
Interface Specifications
Electrical
Characteristics
K-14
Synchronization
Communication
Method
Control System
Connector
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
bps
Asynchronous
Half or full duplex
Hardware control or none
D-sub 25-pin female connector
1
Mounted on the rear of the HG unit
16
12 to 24V DC (allowable range 10 to 28V DC)
Photocoupler
16
12 to 24V DC (allowable range 10 to 28V DC)
Photocoupler
NPN open collector
1.6V maximum
30 mA max. per point, 200 mA total
24-pin connector (Fujitsu FCN-365P024-AG)
2 connectors for inputs and outputs
EIA RS232C compliant
9600, 19200, 38400, 57600, 115200 bps
Asynchronous
Half duplex, proprietary protocol
Mini DIN 8-pin connector
EIA RS485 compliant
38400, 57600, 115200 bps
Asynchronous
Half duplex, proprietary protocol
Special connector
EIA RS232C compliant
Transmission Speed
RS232C
Operator Interfaces
K
Centronics interface compliant
O/I Link
Communication
Electrical Characteristics
Connector
Electrical
Characteristics
Transmission
Speed
Synchronization
Communication
Method
Connector
Electrical
Characteristics
Transmission
Speed
Synchronization
Communication
Method
Connector
EIA RS485 (422) compliant
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
bps
Asynchronous
Half or full duplex
Hardware control or none
D-sub 25-pin female connector
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
SmartTouch Family
Dimensions & Panel Cutouts
HG4F Dimensions
HG4F Installation Panel Layout
Mounting Clip
Panel
270mm
257mm
B
A
HG4F
6mm
A: 258mm + 1mm
B: 332mm + 1mm
Panel thickness: 2 to 5mm
348mm
58mm
Mounting Clip
331mm
HG3F Dimensions
HG3F Installation Panel Layout
Mounting Clip
Panel
240mm
227mm
B
A
HG3F
6mm
A: 228mm + 0.5mm
B: 302mm + 0.5mm
Panel thickness: 2 to 5mm
324mm
301mm
HG2F Dimensions
HG2F Installation Panel Layout
Mounting Clip
Panel
B
126mm
136mm
K
Operator Interfaces
55.8mm
Mounting Clip
A
HG2F
Mounting Clip
56mm
172mm
6mm
A: 126.5mm + .5mm
B: 162.5mm + .5mm
Panel thickness: 1.6 to 5mm
162mm
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-15
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1B Series
HG1B Operator Interface
HG1B - Cost effective graphical interface solutions
HG1B is a 4” size, monochrome LCD touchscreen suitable for small
applications. Its compact size provides an advantage to save space
and money. It has a fast response time (300 msec) which makes it easy
for the user to view data quickly. The built-in library of images and
graphics helps create a simple graphical interface. Moreover with
expandable communications, it can communicate with IDEC PLCs and
many major PLC manufacturers.
• 2 Models available: RS-232 / RS-485 and RS-422
• 127 KB memory, configure up to 100 screens
• Program up to 32 alarm points with an internal buzzer
• Built-in graphic capabilities
• Screen password protection
• Communication drivers for most major PLC manufacturers
• CE marked, UL/c-UL Listed, IP65
• Programmable with WindO/I-NV2 software
Part Numbers: Operator Interface
Description
Communication Type
Part Numbers
4" Monochrome LCD Screen, 24VDC Power Required
RS-232 / RS-485
HG1B-SB22WF
4" Monochrome LCD Screen, 24VDC Power Required
RS-422
HG1B-SB22JF
Part Numbers: Software
Description
Software Name
Programming software for all Touchscreens (PLC Drivers are included with the
software: IDEC, Allen Bradley-DF1, Omron, Mitsubishi, Modicon, Aromat, Siemens, Koyo (Automation Direct), Keyence, Toshiba, and many more)
Operator Interfaces
K
WindO/I-NV2
Part Numbers: Programming Cable
Description
Part Number
HG9Y-ZSS2W
Part Numbers
Programming cable for HG1B Series (PC to HG1B)
HG9Z-XCM1A or FC2A-KC4C
Part Numbers: Cables (to connect between HG1B & PLC)
Manufacturer
Model
Communication Type
Allen Bradley
Aromat
IDEC
Part Numbers
SLC 503/504
RS-232
HG9Z-XC100
Micrologix series
RS-232
HG9Z-XC500
FPO
RS-232
HG9Z-XC300
FA series
RS-232
HG9Z-XC12A
Micro 3
RS-232
HG9Z-XC11A Plus FC2A-KC2 (Both Required)
Micro 3
RS-485
HG9Z-XC19A
Micro 3C
RS-232
HG9Z-XC183
MicroSmart (port 2 w/ FC4A-PC1)
RS-232
HG92-XC183
MicroSmart (port 1 or port 2 w/ FC4A-PC1)
RS-232
FC4A-KC1CA
OpenNet
RS-232
HG9Z-XC183
Automation Direct (Koyo)
DL240
RS-232
HG9Z-XC400
Mitsubishi
FX2N
RS-422
HG9Z-XC305
Part Numbers: Accessories
Description
Mounting brackets for HG1B series (1 per pack)
K-16
www.idec.com
Part Numbers
HG9Z-XK
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1B Series
HG1B Specifications
Safety Standards
UL508, CSA C22-2, No. 142, IEC/EN61131, CE
EMC Standards
EN50081-2, IEC/EN 61131-2
Standards
General Specifications
Electrical
Environmental
24V DC ripple factor: 10% maximum
Voltage variation range
85 to 120% of rated voltage
Power consumption
10W maximum
Instantaneous stopping time
10ms maximum
Inrush current
10A maximum
Dielectric strength
1500V AC, 10 ms, 1 hour (between power or I/O terminal
and ground)
Insulation resistance
In 500V DC megger at least 50MΩ (between power or I/O
terminal and ground)
Operating temperature range
0 to 55˚C (operation)
0 to 50˚C (display contrast)
Operating humidity range
10 to 90% relative humidity (avoid condensation)
Storage temperature
– 20 to +70˚C
Storage humidity
5 to 90% relative humidity (avoid condensation)
Vibration resistance
10 to 55Hz, 10 m/s2 (2 hours each in the X, Y, and Z axes)
Shock resistance
98 m/s2 (5 times each in the X, Y, and Z axes)
Noise resistance
IEC1000-4-4 compliant
Between power terminal and ground: 1k V p-p, 1µs, 1ns
(with noise simulator)
Static electricity resistance
6kV (using a static electricity simulator)
IEC61000-4-2 compliant
Operating atmosphere
No corrosive gases
Installation
Panel mount
Protection rating
IP65
Exterior dimensions (W x H x D)
146mm x 75mm x 70mm
Panel Cutout Dimensions (W x H)
138mm +0.5 x 66mm -0.5
Weight
450g approximate
On-Screen Switches
www.idec.com
Operating method
Resistive touch overlay
Touch points
12 x 4 = 48
Operating pressure
100g or less
Life
1,000,000 operations minimum
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K
Operator Interfaces
Operating
Specifications
Structural
Rated voltage
K-17
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1B Series
Display Specifications
Display elements
Display Specifications
Device
Character Display
Operator Interfaces
K
Display Software Specifications
Graphic Display
STN blue mode LCD
Backlight
Blue, or white
Effective display
3.7" x 1.2" (95 x 31mm)
Number of pixels
192 x 64
Pitch
0.5 x 0.5mm
Pixel size
0.47 x 0.47mm
Element life
At least 50,000 hours
Backlight life
At least 20,000 hours
Size
1/4 size: 8 x 8 dots, 1/2 size: 8 x 16 dots, Full size: 16 x 16 pixel
Number
1/4 size: 24 x 8 lines, 1/2 size: 24 x 4 lines, Full size: 12 x 4 lines
Types
1/4 size: JIS 8-bit code, IBM code page 437, 1/2 size: IDEC font, Full
size: JIS No. 1 standard characters. IDEC font
Attributes
Vertical/horizontal magnification:
1, 2, 3, and 4 times (except 1/4 size), blinking
Graphic elements
Lines, rectangles, circles, arcs, elliptical segments, ellipses,
regular polygons (3 to 8 sided), and bitmap images.
Lines
Solid, thick, and dotted (straight lines only)
Attributes
None
Display Pages
Up to 100 text/graphic pages
Numeric Data Entry
Pop-up numeric keypad
Touch Points
Up to 48 touch points per page
Touch Functions
Toggle digital points on/off, values up/down, change presets, change pages, and
acknowledge alarms
Operator Feedback
Visual/audible feedback of touch input
Text
User-definable as static or dynamic
PLC Support
Communication drivers support most PLCs (see page K-16 for details)
Alarm Confirmation
Internal buzzer
Dimensions & Panel Cutout
Front and Side View Dimensions
Installation Panel Cutout
(75mm)
Installation Panel
Thickness
1.6 to 5mm
(146mm)
(6mm)
K-18
(66mm)
www.idec.com
(138mm)
(64mm)
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1X Family
HG1X Operator Interface
HG1X Text display for small applications
Screens:
Users can easily define as many screens
as allowed by the memory. A list of tasks
can be assigned for each screen. All
screens can be password protected providing an increased level of security.
Various types of objects can be placed
on the screens such as text, data display, alarm object, data entry, bar
graphs, and a user can even import
images (8 line display model only).
Keys:
The keys are user definable. Each key
can have multiple tasks assigned to it,
making them extremely powerful tools
for simple machine control. Create simple alarms with keys assigned to
acknowledge alarms and print or view
next/previous alarms.
LED:
The LEDs provide on/off status for users
to provide for simple monitoring.
Changing Data:
Cursor control (for 2-line display) or keypad (for 4-line and 8-line display) operations are available for easy data entry.
K
Serial Port:
Supports serial printing to print screens.
Great for keeping records or for documentation purposes.
Operator Interfaces
The HG1X series are text message displays with built-in user definable function keys which make them an excellent
tool for small applications. The bright,
back lit LCD screens can display data,
alarms, errors, and data entry. The user
can define as many screens as allowed
by the memory and create multiple
alarms with basic acknowledgements. In
addition, they can communicate with
IDEC PLCs as well as many major brand
PLCs.
• Models available:
-2-line, 16 character display with
24KB memory
-4-line, 20 character display with
24KB memory
-8-line, 20 character display with
64KB memory
• All keys are programmable to do
multiple tasks
• Screen Password protection
• LEDs are programmable for on/off
state
• Serial port for printing screens and
alarms
• Numeric keypad for easy data
entry (4 and 8-line displays only)
• Bitmap import capability (8-line
displays only)
• Communication available for most
major PLC manufacturers
• Class 1 Div 2 (UL 1604) for hazardous locations, UL508, IP65 rated
• All models are programmable with
WINDMSG software
Part Numbers: Operator Interface
Description
Communication Type
Part Numbers
2-Line Text Message Display, No External Power Required
RS-232
HG1X-252
2-Line Text Message Display, 24VDC Power Required
RS-232 / RS-485
HG1X-222
4-Line Text Message Display, No External Power Required
RS-232
HG1X-452
4-Line Text Message Display, 24VDC Power Required
RS-232 / RS-485
HG1X-422
8-Line Text Message Display, 24VDC Power Required
RS-232 / RS-485
HG1X-822
All HG1X models come with mounting clips and a gasket.
Part Numbers: Replacement Parts
Description
Model
Hardware Set: 2 pieces mounting clips & 1 gasket
www.idec.com
Part Numbers
for HG1X-252/222
HG9Z-MTHW160D
for HG1X-452/422/822
HG9Z-MTHW170D
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K-19
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1X Family
WindMSG Software
HG1X Software:
User-friendly WINDMSG software programs all text message displays. It has a
drop down menus and icons for convenient function selection. Objects are easily configured using step by step
navigation. PLC drivers are built into the
software, which allows for extended
communication with IDEC and many
other popular PLC manufacturers.
Part Numbers: Software
Description
Software Name
Programming software for all HG1X Series*
Part Number
WINDMSG
WINDMSG
*Includes communication drivers for all major PLC brands: AB-DFI*, Mitsubishi, Aromat, Siemens,
Koyo, Modicon, Keyence
Part Numbers: Programming Cable
Description
Programming cable for HG1X Series (PC TO HG1X)
Part Number
HG9Z-PC125A
Part Numbers: Cables - Connect between HG1X-252 / 452 to PLC
Manufacturer
Model
Communication Type
ALLEN BRADLEY
Micrologix Series
RS-232
HG9Z-SCI007
AROMAT
FP0/FPM
RS-232
HG9Z-SCI015
Micro 3
RS-232
HG9Z-SCI25A (built-in converter)
Micro 3C
RS-232
HG9Z-SCI25B
MicroSmart
RS-232
HG9Z-SCI25B
OpenNet
RS-232
HG9Z-SCI25B
Automation Direct (KOYO)
DL 205 Series
RS-232
HG9Z-SCI023
MITSUBISHI
FX0
RS-232
HG9Z-SCI008 (built-in converter)
SIEMENS
S7-200
RS-232
HG9Z-SCI029
K
IDEC
Operator Interfaces
Part Numbers
Part Numbers: Cables - Connect between HG1X-222 / 422 / 822 and PLC
Manufacturer
Model
Communication Type
Part Numbers
ALLEN BRADLEY
AROMAT
Micrologix series
RS-232
HG9Z-SCI100
SLC 500 series
RS-232
HG9Z-SCI120
FP0/FPM
RS-232
HG9Z-SCI500
Micro 3
RS-485
HG9Z-SCI220
Micro 3C
RS-232
HG9Z-SCI200
MicroSmart
RS-232
HG9Z-SCI200
OpenNet
RS-232
HG9Z-SCI200
Automation Direct (KOYO)
DL 205 Series
RS-232
HG9Z-SCI400
MITSUBISHI
FX0
RS-232
HG9Z-SCI600
SIEMENS
S7-200
RS-485
HG9Z-SCI300
IDEC
HG1X-252/452 support Micrologix only, HG1X-222/422/822 support Micrologix and
SLC 5 00 series PLCs
K-20
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1X Family
HG1X Specifications
HG1X-252/HG1X-452
Standards
General Specifications
Electrical
Environmental
Structural
Safety standards
UL508, UL1604
UL508, UL1604
EMC standards
Immunity to ESD: Level 3 as per IEC 61000-4-2
Transient Immunity: Level 3 as per IEC 61000-4-4
Radianted Immunity: Level 3 as per IEC 61000-4-3
Emissions: EN55011 CISPR A
Conducted RF Susceptibility: as per IEC 61000-4-6
Immunity to ESD: Level 3 as per IEC 61000-4-2
Transient Immunity: Level 3 as per IEC 61000-4-4
Radianted Immunity: Level 3 as per IEC 61000-4-3
Emissions: EN55011 CISPR A
Conducted RF Susceptibility: as per IEC 61000-4-6
Rated voltage
5V DC
24 VDC
Voltage variation range
5 VDC (+/-) 5%
24 VDC (+/-) 10%
Power consumption
HG1X-252: 120mA maximum
HG1X-452: 160mA maximum
HG1X-222: 1 watt typical; 3 watt maximum
HG1X-422: 1.5 watt; 3 watt maximum
HG1X-822: 2.5 watt; 3 watt maximum
Inrush current
N/A
HG1X-222: 45mA @24 VDC
HG1X-422: 55mA @24 VDC
HG1X-822: 115ma @24 VDC
Operating temperature range
0 to 55˚C
0 to 55˚C
Operating humidity range
0 to 90% (non-condensing)
10 to 90% (non-condensing)
Degree of Protection
IP65 standards
IP65 standards
Storage temperature
– 25 to +80˚C
– 25 to +80˚C
Storage humidity
90% RH
95% RH
Vibration resistance
10 to 61.2Hz, @ 0.2mm displacement
61.2Hz to 150Hz @ 1.5G acceleration (on all axes)
10 to 61.2Hz, @ 0.2mm displacement
61.2Hz to 150Hz @ 1.5G acceleration (on all axes)
Shock resistance
1.5G acceleration for 11ms,
2 shocks per sense per axis (on all axes)
1.5G acceleration for 11ms,
2 shocks per sense per axis (on all axes)
Installation
Panel mount
Panel mount
Exterior dimensions
(W x H x D in mm)
HG1X-252: 108 x 61 x 27
HG1X-452: 183 x 101 x 37
HG1X-222: 108 x 61 x 27
HG1X-422: 183 x 101 x 37
HG1X-822: 183 x 101 x 37
Panel cutout dimensions
in mm
HG1X-252: 92 x 45
HG1X-452: 161 x 79
HG1X-222: 92 x 45
HG1X-422: 161 x 79
HG1X-822: 162 x 79
Weight
HG1X-252: 137g
HG1X-452: 318g
HG1X-222: 150g
HG1X-422: 340g
HG1X-822: 366g
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
K
Operator Interfaces
www.idec.com
HG1X-222/HG1X-422/HG1X-822
K-21
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Operator Interfaces
HG1X Family
Dimensions & Panel Cutout
HG1X-252/HG1X-222 Dimensions/Panel Cutout
Bezel
Gasket (For IP65 Sealing)
108.30 mm
27.10 mm
44.18 mm
60.50 mm
91.20 mm
CUTOUT
Panel
HG1X-452/HG1X-422/HG1X-822 Dimensions/Panel Cutout
Bezel
Gasket (For IP65 Sealing)
182.50 mm
78.50 mm
101.30 mm
160.70 mm
36.80 mm
CUTOUT
Panel
Operator Interfaces
K
K-22
www.idec.com
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising