Planning information WMF 5000 S
100
105
130
4,4
325
5
500 height for coin changer
502 for coin checker
624
536,2
800,6
705,1
Optional: Payment system
130 width for card reader
105 for coin checker and
coin changer
Optional:
Feet 100mm
O 30
Optional:
Pipe for discharged grounds
70x120x250mm
second pipe can be used for
extension if needed
590
Optional:
Grounds discharged
through counter
245
58
125
271
140
110
O 30
233
100
87
Optional :
TW8
TW8
EH
provided Route for milk pipe
by customer counter cooler
FIL
80 μm
42
46
100
233
Optional:
Area for connections through the counter
(Water, Drainage, Electricity)
Min 50x60 or 70 diameter
Can be placed anywhere in the area marked
in red
if used with under
TW10 (Eckventil)
2,75 - 3,25 kW
1/N/PE/~50Hz 230V
oder
3x1,5mm², Length approx. 1m
5,9 - 7,1 kW
3/N/PE/~50Hz 400V
5x2,5mm², Length approx. . 2,5m
provided
by customer
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF United Kingdom Limited| 31 Riverside Way | Uxbridge UB8 2YF
Page. 1 / 3
WMF COFFEMACHINES
μ
General: Usage and installation conditions
The preparatory conditions for the mains electricity, water and drainage connections at the customer premises
are a matter for the machine’s user. They must be undertaken by licensed installers and comply with general,
national and local regulations. The WMF service team can only connect the coffee machine to these
preprepared connections. They are not allowed to perform installation work to customer premises, and cannot
be held responsible for such work. If required, the Equipotential Terminal can be fitted by the WMF service
team.
Dimensions and
empty weight:
Data sheet WMF 5000 S
Width:
Height:
Depth:
Height of spout:
325 mm
706 mm
590 mm
66 – 171 mm (for Easy Milk)
74 – 179 mm (for Dynamic Milk)
Weight:
approx. 37 kg
Water connection:
Water pressure:
Water temperature:
3/8" hose connection with main tap and filter, provided by customer
Min. 0,2 MPa (2 bar) flow pressure at 2 l/min. Max. 0,6 MPa (6 bar)
Max. 35°C
Precautions taken at the customers premised prior to installation:
Water connection:
Drainage pipe:
Pipe min. DN 19, Gradient at least 2 cm/m.
2,75 - 3,25 kW
or 5,9 - 7,1 kW
Rated power:
220 - 240 V 50/60Hz 1/N/PE or. 380 - 415V 50/60 Hz 3/N/PE
Mains connection:
IPX0
Protection system:
One
Protection class:
Installation distances: For reasons of function, service and safety, the machine must be installed a minimum distance
of 50mm at the rear and side, away from any fixed installations/any non-WMF parts.
The minimum height of installation is 850mm from the floor surface.
If the coffee machine’s connecting pipes are to be led through and below the counter, make
sure space is reserved for the pipes, which will reduce the available room under the counter. If
a water filter is used for the machine, please allow further room for the installation of the filter.
Refer to the manual of the water filter for additional information.
Electricity:
Installation surface:
The appliance must be installed horizontally on a horizontal, stable, water-resistant
surface that is not sensitive to heat.
The appliance is not suitable for installation on a surface which is sprayed or cleaned
with a hose, steam jet cleaner, steam cleaner or similar.
http://www.wmf-kaffeemaschinen.de/fachplaner
WMF United Kingdom Limited| 31 Riverside Way | Uxbridge UB8 2YF
Page. 2 / 3
μ
WMF COFFEEMACHINES
Mains connection:
These specifications for the mains connection and the norms cited apply to the installation of
this coffee machine in the member states of the EU. In some cases, additional, country-specific
rules must also be considered. Outside the countries of the EU, the acceptance of the norms
cited must be checked by the retailers of the coffee machine.
The customer’s electrical system must comply with IEC 364 (DIN VDE 0100).
Near the appliance there should be a Schuko plug socket or other single-phase socket specific
to the country of use, accessible at all times and unobstructed on a single-phase connection.
For three-phase connections there should be a 5-pole CEE/ CEKON-Socket based on EN
60309. The plug sockets are part of the customer’s installation.
The power cable should not be incontact with hot parts. If the power cable is damaged, it will
have to replaced by our service team or another qualified person. This is to avoid dangerour
situations.
Important information regarding payment systems:
If a card reader is being used and depending on specification, it might be neccessary
to install an additional and protected Schuko plug. Please double check with the
supplier of the payment system.
To prevent any interference with our shielded data lines by equipotential currents between
the devices, an additional equipotential bonding should be installed for devices connected to
an accounting system. Please see VDE 0800-2.
Water supply
and drainage:
The water supply pipe must be situated near the appliance (maximum 800mm away). In the
water supply, an appropriately-sized stopcock (preferably a ball cock) and a sediment filter,
mesh size 0.8mm, should be installed under the counters and freely accessible at all times.
For a drainage connection, the drainage must be fitted to the rear wall of the under-counter
space, 50 CM away from the counter surface.
For a ventilated drainage pipe, a syphon pipe must be installed (a hose connection should be
fitted with a a valve and hose ring holder).
For a connection from below through the counter, a gap or hole in the counter of the relevant
size should be provided in one of the hatched areas (see diagram).
If the water is harder than 5° dKH a WMF water filter must be used.
Other:
Ambient Temperature: + 5°C to +35°C (if below 0°C empty water container)
Max. Humidity:
80% rel. humidity without condensation
Do not use outdoors
Palpable heat loss:
0,1 kWh/h in Stand-by mode
3,25 kWh/h bzw. 6,4 kWh/h whilst at peak use
Continuous sound pressure level:
< 70 dB (A)
You can find further information about the usage instructions, safety data sheets and certificates here:
http://www.servicecenter.wmf.de/
All of the above information relates to machines and appliances conforming to the
standard specifications. Customised equipment and custom solutions may differ.
http://www.wmf-kaffeemaschinen.de/fachplaner