MCode Programming and Software Reference

MCode Programming and Software Reference
Programming and Software
Reference for:
• MCode
• MCode/TCP
MDrive, MForce and
Hybrid Motion Control
Products
MCode Programming and Software Reference
Date
Revision
Changes
03/08/2006
R030806
Initial Release
02/16/2007
R021607
Added TR as a reserved for future use word.
04/20/2007
R042007
Revised manual to reflect firmware version MDI3.006. Added D5, analog input filter variable, various corrections and expansions of commands, updated
error table.
10/25/2007
R102507
Revised manual to reflect firmware version MDI3.007
02/27/2008
R022708
Revised Manual to reflect firmware version MDI3.008. Added QD (Qeued
- Page 45) command and PW variable (Page 44 and Appendex G: MForce
PWM Current Control).
06/16/08
R061608
Updated covers, added disclaimer information. Expanded on Trip definitions.
Expanded on Error 92. Minor corrections throughout.
08/14/2008
R081408
Added NE (Numeric Enable Command. Relevant to Firmware Version 3.009
04/29/2009
R080409
Added Hybrid commands, reformated to reflect current documentation standards and styling. Updated to reflect firmware release 3.010.
08/04/2009
R080409
Added Error 63 - character overrun
07/10/2009
R071009
Added Hybrid Flag AF, added errors 87, 88 and 89 for Hybrid
11/23/2009
R112309
Appended the HT (Hold Current Delay Time) command to reflect the behavioral difference between Legacy and Plus MDrive units.
02/25/2010
R022510
Updates and corrections throughout.
07/02/2010
R070210
Updates and corrections throughout. Added warning about enabling clock
mode when using limits (pg 5-12).
10/05/2010
R100510
Added support for MDrive Ethernet products. Section 6: IMS Terminal
renamed to Section 6: Supporting Software with the addition of instructions
for the TCP/IP Configuration Utility for MDrive Ethernet and MDrive Hybrid
Ethernet. Changed name of MDrive AccuStep to MDrive Hybrid throughout.
02/14/2011
R021411
Added procedure for upgrading Ethernet Controller firmware for Ethernet
equipped MDrivePlus and MDrive Hybrid models.
04/12/2011
R041211
Added support for MDrive Hybrid firmware version 4.004
08/05/2011
R080511
Added second parameter details supporting hybrid calibration. Added correct
range for torque speed and system speed.
06/28/2012
R062812
Added changes supporting default MDrive Hybrid calibration method.
The information in Schneider Electric Motion USA product documentation
and on this web site has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies.
Schneider Electric Motion USA reserves the right to make changes without further notice to any products to improve reliability, function or design.
Schneider Electric Motion USA does not assume any liability arising out of
the application or use of any product or circuit described; neither does it
convey any license under its patent rights of others.
Schneider Electric Motion USA’s general policy does not recommend the
use of its products in life support or aircraft applications wherein a failure
or malfunction of the product may directly threaten life or injury. Per the
terms and conditions of sales of Schneider Electric Motion USA, the user
of Schneider Electric Motion USA products in life support or aircraft applications assumes all risks of such use and indemnifies Schneider Electric
Motion USA against all damages. aircraft applications assumes all risks
of such use and indemnifies Schneider Electric Motion USA against all
damages.
MCode Programming and Software Reference Revision R062812
Copyright © Schneider Electric Motion USA, All Rights Reserved
Important information
The drive systems described here are products for general use that conform
to the state of the art in technology and are designed to prevent any dangers.
However, drives and drive controllers that are not specifically designed for
safety functions are not approved for applications where the functioning of
the drive could endanger persons. The possibility of unexpected or un-braked
movements can never be totally excluded without additional safety equipment.
For this reason personnel must never be in the danger zone of the drives unless additional suitable safety equipment prevents any personal danger. This
applies to operation of the machine during production and also to all service
and maintenance work on drives and the machine. The machine design must
ensure personal safety. Suitable measures for prevention of property damage
are also required.
Qualification of personnel
Only technicians who are familiar with and understand the contents of this
manual and the other relevant documentation are authorized to work on
and with this drive system. The technicians must be able to detect potential
dangers that may be caused by setting parameters, changing parameter
values and generally by the operation of mechanical, electrical and electronic
equipment.
The technicians must have sufficient technical training, knowledge and experience to recognise and avoid dangers.
The technicians must be familiar with the relevant standards, regulations and
safety regulations that must be observed when working on the drive system.
Intended Use
The drive systems described here are products for general use that conform
to the state of the art in technology and are designed to prevent any dangers.
However, drives and drive controllers that are not specifically designed for
safety functions are not approved for applications where the functioning of
the drive could endanger persons. The possibility of unexpected or unbraked
movements can never be totally excluded without additional safety equipment.
For this reason personnel must never be in the danger zone of the drives unless additional suitable safety equipment prevents any personal danger. This
applies to operation of the machine during production and also to all service
and maintenance work on drives and the machine. The machine design must
ensure personal safety. Suitable measures for prevention of property damage
are also required.
In all cases the applicable safety regulations and the specified operating conditions, such as environmental conditions and specified technical data, must
be observed.
The drive system must not be commissioned and operated until completion
of installation in accordance with the EMC regulations and the specifications
in this manual. To prevent personal injury and damage to property damaged
drive systems must not be installed or operated.
Changes and modifications of the drive systems are not permitted and if made
all no warranty and liability will be accepted.
The drive system must be operated only with the specified wiring and approved accessories. In general, use only original accessories and spare parts.
The drive systems must not be operated in an environment subject to explosion hazard (ex area).
This page intentionally left blank
MCode Programming and Software Reference
Table of Contents
Table of Contents
Important information .................................................................... 3
Qualification of personnel.............................................................. 3
Intended Use ................................................................................. 3
1
Introduction ................................................................................ 1-1
1.1
1.2
1.3
1.4
2
Safety .......................................................................................... 2-1
2.1
2.2
2.3
2.4
3
Qualification of personnel ................................................2-1
Intended Use ...................................................................2-1
Hazard Categories ..........................................................2-2
General safety instructions ..............................................2-2
Introduction to MCode programming ...................................... 3-1
3.1
3.2
3.3
3.4
4
About this manual............................................................1-1
MCode device overview ..................................................1-1
Documentation reference ................................................1-1
Product software .............................................................1-1
1.4.1 Communications converter drivers ....................1-1
1.4.2 ASCII program editor and ANSI terminal emulator .
1-1
Operational modes ..........................................................3-1
Basic components of MCode software ............................3-1
3.2.1 Instructions .......................................................3-1
3.2.2 Variables ............................................................3-2
3.2.3 Flags ..................................................................3-3
3.2.4 Keywords ...........................................................3-3
3.2.5 Math functions ...................................................3-4
Program structuring .........................................................3-4
3.3.1 Programming aids..............................................3-5
Commonly used variables and instructions .....................3-6
3.4.1 Variables ............................................................3-6
3.4.2 Motion instructions .............................................3-7
3.4.3 I/O instructions ...................................................3-9
3.4.4 System instructions..........................................3-10
3.4.5 Program instructions ........................................3-11
Command summary .................................................................. 4-1
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4-6
4.8
4.9
Revision R062812
5
Setup instructions, variables and flags ..............4-1
Misc instructions, variables and flags ................4-2
Motion instructions, variables and flags .............4-3
Program instructions, variables and flags ..........4-4
I/O instructions, variables and flags ...................4-5
Position related instructions, variables and flags4-6
Encoder related instructions, variables and flags ...
Hybrid specific instructions, variables and flags 4-7
Math functions ...................................................4-8
MCode command details .......................................................... 5-1
A (Acceleration)..........................................................................5-1
AL (Retreive all parameters) ......................................................5-1
AF (Hybrid flags) ........................................................................5-2
AS (Hybrid mode).......................................................................5-3
AT (Reservef) .............................................................................5-3
BD (Communications BAUD rate) ..............................................5-4
BP (Break point) .........................................................................5-5
i
Table of Contents
MCode Programming and Software Reference
Revision R062812
BR (Program branch) .................................................................5-6
BY (Program executing) .............................................................5-6
C1 (Counter 1) ...........................................................................5-7
C2 (Counter 2) ...........................................................................5-7
CA (Calibration mode)................................................................5-8
CB (Control bounds) ..................................................................5-9
CC (Calibration current) .............................................................5-9
CE (Software reset enable) ......................................................5-10
CF (Clear locked rotor fault) .....................................................5-10
CK (Check sum enable) ...........................................................5-11
CL (Call subroutine) .................................................................5-12
CM (Clock mode enable) .........................................................5-12
CP (Clear program) ..................................................................5-13
CR (Clock ratio)........................................................................5-13
CT (Calibration time) ................................................................5-14
CW (Clock width) .....................................................................5-14
D (Deceleration) .......................................................................5-15
D1-D4 (Input switch debounce)................................................5-15
D5 (Analog input filter) .............................................................5-16
D9-D12 (Input switch debounce)..............................................5-16
DB (Encoder deadband) ..........................................................5-17
DC (Decrement variable) .........................................................5-17
DE (Drive enable).....................................................................5-18
DG (Disable global response) ..................................................5-18
DN (Device name)....................................................................5-19
E (End program).......................................................................5-19
EE (Encoder enable) ................................................................5-20
EF (Error flag) ..........................................................................5-20
EL (Remote encoder line count) ..............................................5-21
EM (Echo mode) ......................................................................5-21
ER (Device name) ....................................................................5-22
ES (Escape) .............................................................................5-22
EX (Execute program)..............................................................5-23
FC (Filter capture) ....................................................................5-24
FD (Restore factory defaults) ...................................................5-25
FM (Filter motion) .....................................................................5-25
FT (Internal use only) ...............................................................5-26
H (Hold program execution) .....................................................5-26
HC (Motor holding current).......................................................5-27
HI (Home to index mark) ..........................................................5-28
HM (Home to home switch)......................................................5-29
HT (Hold current delay time) ....................................................5-31
I1, I2, I3 and I4 (Read inputs 1, 2 ,3 or 4) ................................5-31
I5 (Read analog input)..............................................................5-32
I6 (Read encoder index mark)..................................................5-32
I7, I8 (Reserved) ......................................................................5-32
I9, I10, I11 and I2 (Read inputs 9, 10, 11 or 12) ......................5-33
I13 (Reserved) .........................................................................5-33
IC (Increment variable).............................................................5-33
IF (Input variable pending) .......................................................5-34
IL (Read inputs 1 - 4 as a group) .............................................5-34
IH (Read inputs 9 - 12 as a group) ...........................................5-35
IN (Read inputs 1 - 4 and 9 - 12 as a group)............................5-35
IP (Initialize parameters) ..........................................................5-36
IT (Read internal temperature) .................................................5-36
IV (Input to variable) .................................................................5-37
JE (Jog enable) ........................................................................5-37
ii
Revision R062812
MCode Programming and Software Reference
Table of Contents
L (List program space) .............................................................5-38
LB (Label program or subroutine) ............................................5-38
LD (Lead limits) ........................................................................5-39
LG (Lag limits) ..........................................................................5-39
LL (Position lead/lag) ...............................................................5-40
LK (Lock user program) ...........................................................5-40
LM (Limit stop modes)..............................................................5-41
LR (Locked rotor) .....................................................................5-42
LT (Locked rotor timeout) .........................................................5-42
MA (Move to an absolute position)...........................................5-43
MD (Motion mode) ...................................................................5-43
MF (Make up frequency) ..........................................................5-44
MP (Moving to position) ...........................................................5-44
MR (Move to a relative position) ..............................................5-45
MS (Microstep resolution select) ..............................................5-46
MT (Motor settling delay time)..................................................5-47
MU (Make up mode) ................................................................5-48
MV (Moving) .............................................................................5-48
NE (Numeric enable)................................................................5-49
O1, O2, O3 and O4 (Set outputs 1, 2 ,3 or 4) ..........................5-49
O9, O10, O11 and O12 (Set outputs 9, 10 ,11 or 12) ..............5-50
OE (On error handler) ..............................................................5-50
OL (Set outputs 1 - 4 as a group).............................................5-51
OH (Set outputs 9 - 12 as a group) ..........................................5-51
OT (Set outputs 1- 4 and 9 - 12 as a group) ...........................5-52
P (Position counter)..................................................................5-52
PC (Position capture at trip) .....................................................5-53
PG (Program mode))................................................................5-53
PM (Position maintenance enable) ..........................................5-54
PN (Part number) .....................................................................5-54
PR (Print specified data or text) ...............................................5-55
PS (Pause program execution) ................................................5-55
PW (PWM configuration)..........................................................5-56
PY (Party mode enable) ...........................................................5-57
QD (Queued)............................................................................5-58
R1, R2, R3 and R4 (User registers) .........................................5-58
RC (Motor run current) .............................................................5-59
RS (Resume program execution).............................................5-59
RT (Return from subroutine) ....................................................5-60
S (Save to NVM) ......................................................................5-60
S1, S2, S3, S4, S9, S10, S11, S12 (Setup I/O 1 - 4 & 9 - 12)..5-61
S5 (Set analog input) ...............................................................5-63
S7 & S8 (Setup clock I/O points)..............................................5-64
S13 (Setup capture input/trip output) .......................................5-65
SC (Start calibration) ................................................................5-65
SF (Stall factor) ........................................................................5-66
SL (Slew axis) ..........................................................................5-66
SM (Stall detect mode).............................................................5-67
SN (Serial number) ..................................................................5-67
SS (System speed) ..................................................................5-68
ST (Stall flag) ...........................................................................5-68
SU (Execute program on power up).........................................5-69
TA (Trip on Hybrid status) ........................................................5-69
TC (Trip capture) ......................................................................5-70
TD (Torque direction) ...............................................................5-70
TE (Trip enable) .......................................................................5-71
TI (Trip on input).......................................................................5-71
iii
MCode Programming and Software Reference
Table of Contents
TP (Trip on position).................................................................5-72
TQ (Set torque) ........................................................................5-72
TR (Trip on relative position) ....................................................5-73
TS (Set torque speed) ..............................................................5-74
TT (Trip on position) .................................................................5-74
UG (Upgrade firmware) ............................................................5-75
UV (Read user variables) .........................................................5-75
V (Read velocity) ......................................................................5-75
VA (Create user variable).........................................................5-76
VC (Velocity changing).............................................................5-76
VI (Initial velocity) .....................................................................5-77
VM (Maximum velocity) ............................................................5-77
VR (Firmware version) .............................................................5-78
WT (Warning temperature) ......................................................5-78
6
Supporting Software ................................................................. 6-1
6.1
6.2
7
Programming and application notes ....................................... 7-1
7.1
7.2
Revision R062812
7.3
7.4
iv
IMS Terminal ...................................................................6-1
6.1.2 Features.............................................................6-1
6.1.3 Installing IMS Terminal ......................................6-2
6.1.4 Screen and menu overview ...............................6-2
6.4.2 The menu bar structure and operation ..............6-3
6.4.3 Edit menu operation...........................................6-3
6.1.5 Configuring IMS Terminal ..................................6-5
6.1.6 Troubleshooting communications ......................6-7
6.1.7 Configuring function keys ..................................6-8
6.1.8 Creating, downloading and uploading programs ....
6-10
6.1.9 Program troubleshooting using IMS Terminal .6-12
6.1.10 Upgrading firmware .........................................6-14
TCP/IP Configuration Utility...........................................6-18
6.2.1 Installation........................................................6-18
6.2.2 Screen overview ..............................................6-18
6.2.3 Configuration ...................................................6-19
6.2.4 SEM Port tab ...................................................6-20
Party mode communications ...........................................7-1
7.1.1 Response to Echo Mode ...................................7-1
7.1.2 Using Check Sum ..............................................7-3
7.1.3 Immediate party mode sample codes ................7-4
Programming the I/O .......................................................7-5
7.2.1 I/O availability per device type ...........................7-5
7.2.2 Active states defined..........................................7-6
7.2.3 Digital input functions.........................................7-6
7.2.4 Digital output functions ......................................7-9
7.2.5 Programmable I/O usage examples ................7-10
7.2.6 Dedicated digital I/O usage..............................7-13
7.2.7 Analog input usage .........................................7-15
Factors impacting motion commands............................7-16
7.3.1 Motor steps ......................................................7-16
7.3.2 Microsteps: (MS) .............................................7-16
7.3.3 Move Command ..............................................7-16
7.3.4 Closed loop control with an encoder................7-16
7.3.5 Linear movement .............................................7-17
7.3.6 Calculating rotary movement ...........................7-19
7.3.7 Programming with the optional encoder enabled 7-21
MForce PWM configuration ...........................................7-25
7.4.1 Description: ......................................................7-25
MCode Programming and Software Reference
Table of Contents
7.4.2
7.4.3
7.4.4
7.4.5
PWM Mask <mask> Parameter .......................7-25
Max PWM duty cycle (%) <period> parameter 7-26
PWM frequency <sfreq> parameter.................7-27
PWM checksum <chksum> parameter ..................
(boot write only) ...............................................7-28
7.4.6 Boot writes remaining <boot_writes_remaining> ...
parameter (read only) ......................................7-29
7.4.7 Example PWM settings by motor ...........................
specifications ...................................................7-29
8
Sample programs ...................................................................... 8-1
8.1
8.2
8.3
8.4
8.5
8.6
8.7
9
Move on an input .............................................................8-1
Change velocity during a move .......................................8-2
Binary mask.....................................................................8-3
Closed lLoop ...................................................................8-5
User input into variables ..................................................8-6
Closed loop with homing .................................................8-7
Input trip ..........................................................................8-8
Error codes ................................................................................ 9-1
I/O errors .........................................................................9-1
Data errors ......................................................................9-1
Program errors ................................................................9-2
Communications errors ...................................................9-2
System errors ..................................................................9-3
Motion errors ...................................................................9-3
Hybrid errors....................................................................9-4
Revision R062812
9.1
9.2
9.3
9.4
9.5
9.6
9.7
v
MCode Programming and Software Reference
Table of Contents
List of Figures
Figure 3.1
Figure 5.1
Figure 5.2
Figure 6.1
Figure 6.2
Figure 7.1
Figure 7.2
Figure 7.3
Figure 7.4
Figure 7.5
Figure 7.6
Figure 7.7
Figure 7.8
Recommended MCode program structure ............................3-4
Homing functions sequence of events ................................5-30
Limit modes of operation .....................................................5-41
IMS Terminal main screen ....................................................6-2
Function key setup dialog.....................................................6-8
Step/direction I/O type & configuration ................................7-13
Quadrature I/O configuration ...............................................7-14
CW/CCW I/O configuration .................................................7-14
Trapezoidal move profile .....................................................7-17
Rotary examples .................................................................7-19
Encoder waveform ..............................................................7-21
PWM mask bits ...................................................................7-26
PWM frequency range.........................................................7-27
Table 7.1
Response to echo mode - party and check sum are
zero (0) ..................................................................................7-2
Response to echo mode - party is one (1) and check
sum is zero (0) .....................................................................7-3
Response to echo mode - party is zero (0) and
check sum is one (1) ...........................................................7-3
Response to echo mode - party and check sum are
one (1) ..................................................................................7-3
Digital input functions ..........................................................7-7
Clock and high speed input functions ..................................7-8
Digital output functions ........................................................7-9
Clock and high speed output functions .............................7-10
PWM Mask Settings ...........................................................7-26
Typical PWM Mask Settings...............................................7-26
Maximum PWM frequency ..................................................7-27
Initial PWM frequency .........................................................7-27
Example PWM settings .......................................................7-29
List of Tables
Table 7.2
Table 7.3
Table 7.4:
Revision R062812
Table 7.5
Table 7.6
Table 7.7
Table 7.8
Table 7.8
Table 7.9
Table 7.10
Table 7.11
Table 7.12
vi
MCode Programming and Software Reference
1
Introduction
1.1
About this manual
1 Introduction
This manual is devices utilizing the MCode programming language.
1.2
MCode versions
1.2.1
MCode
MCode is the programming and control language for products communicating over serial RS-422/485.
1.2.2
MCode/TCP
MCode/TCP is the MCode language adapted to communicate over
Ethernet TCP/IP networks. The function and usage is identical with the
exception that the commands related to RS-422/485 communication are
disabled. MCode/TCP will connect to TCP or UDP port 503.
1.3
MCode device overview
The following product lines use MCode for configuration and programming:

MDrive Motion Control products

MForce Motion Control products

MDrive Hybrid Motion Control products
Many of the MCode commands are device-specific based on available
I/O, Hybrid Motion Technology and communications interface. In the
command detail (Section 5), each command is listed with device compatibility. Ensure that the command will function with your device before
using.
1.4
Documentation reference
Revision R062812
The following user’s manuals are available for the MCode devices:

Product hardware manual, describes the technical data and
installation of the product.

Product software manual, describes the configuration and programming of the product.

Quick Reference, describes the basic wiring, connection and
use of this product. The quick reference is shipped in printed
form with the product.
This documentation is also available for download from our web site at:
http://motion.schneider-electric.com
1-1
1 Introduction
1.4.1
1.5
MCode Programming and Software Reference
Related documents
MODBUS/TCP
The MODBUS/TCP Fieldbus manual describes the implementation of
the MODBUS protocol for Ethernet equipped MDrive products. When
connected to TCP port 502, the MDrive Ethernet will only respond to
MODBUS commands.
EtherNet/IP
The EtherNet/IP Fieldbus manual describes the implementation of the
EtherNet/IP protocol for Ethernet equipped MDrive products.
Product software T
The following drivers and software may be downloaded from the web
site at: http://www.schneider-electric-motion.us/downloads/software_interfaces.html
1.5.1
Communications converter drivers
If using the MD-CC40x-001 communications converter, drivers are
required, these drivers are available for download from our web site at
http://www.schneider-electric-motion.us/downloads/cable_drivers.html.
1.5.2
ASCII program editor and ANSI terminal emulator
Motion control products may be configured and programmed using any
standard ANSI terminal emulator and ASCII text editor.
The recommended tool is the IMS Terminal integrated terminal and program editor. IMS Terminal features color-coded editor, multiple-function
keys and is pre-configured to operate using the MDrive default settings
Installation and usages instructions are to be found in MCode software
manual.
1.5.3
TCP/IP configuration utility
The TCP/IP configuration utility is a user interface for configuring the
Ethernet equipped MDrive models in either EtherNet/IP MCode/TCP or
MODBUS/TCP.
This GUI offers basic setup and test functionality and is required
to change the MDrive’s IP/SubNet address from the default
192.168.33.1/255.255.0.0.
Revision R062812
IMS Terminal is then recommended for programming the MDrive in
MCode/TCP mode.
1-2
MCode Programming and Software Reference
2
Safety
2.1
Qualification of personnel
2 Safety
Only technicians who are familiar with and understand the contents
of this manual and the other relevant documentation are authorized
to work on and with this drive system. The technicians must be able
to detect potential dangers that may be caused by setting parameters, changing parameter values and generally by the operation of
mechanical, electrical and electronic equipment.
The technicians must have sufficient technical training, knowledge
and experience to recognise and avoid dangers.
The technicians must be familiar with the relevant standards, regulations and safety regulations that must be observed when working on
the drive system.
2.2
Intended Use
The drive systems described here are products for general use that
conform to the state of the art in technology and are designed to prevent any dangers. However, drives and drive controllers that are not
specifically designed for safety functions are not approved for applications where the functioning of the drive could endanger persons.
The possibility of unexpected or unbraked movements can never be
totally excluded without additional safety equipment.
For this reason personnel must never be in the danger zone of the
drives unless additional suitable safety equipment prevents any
personal danger. This applies to operation of the machine during
production and also to all service and maintenance work on drives
and the machine. The machine design must ensure personal safety.
Suitable measures for prevention of property damage are also required.
In all cases the applicable safety regulations and the specified operating conditions, such as environmental conditions and specified
technical data, must be observed.
Revision R062812
The drive system must not be commissioned and operated until
completion of installation in accordance with the EMC regulations
and the specifications in this manual. To prevent personal injury and
damage to property damaged drive systems must not be installed or
operated.
Changes and modifications of the drive systems are not permitted
and if made no warranty and liability will be accepted.
The drive system must be operated only with the specified wiring
and approved accessories. In general, use only original accessories
and spare parts.
2-1
2 Safety
MCode Programming and Software Reference
The drive systems must not be operated in an environment subject
to explosion hazard (ex area).
2.3
Hazard Categories
Safety notes and general information are indicated by hazard messages in the manual. In addition there are symbols and instructions
affixed to the product that warn of possible hazards and help to
operate the product safely.
Depending on the seriousness of the hazard, the messages are
divided into three hazard categories.
DANGER indicates an imminently hazardous situation, which,
if not avoided, will result in death or serious injury.
WARNING indicates a potentially hazardous situation, which, if
not avoided, can result in death, serious injury, or equipment
damage.
CAUTION indicates a potentially hazardous situation, which, if
not avoided, can result in injury or equipment damage.
Revision R062812
CAUTION used without the safety alert symbol, is used to address practices not related to personal injury (e.g. can result in
equipment damage).
2-2
MCode Programming and Software Reference
2.4
2 Safety
General safety instructions
! DANGER
UNINTENDED CONSEQUENCES OF EQUIPMENT OPERATION
When the system is started, the drives are usually out of the
operator’s view and cannot be visually monitored.
• Only start the system if there are no persons in the hazardous
area
Failure to follow these instructions will result in death or
serious injury.
! DANGER
EXPOSED SIGNALS
Hazardous voltage levels may be present if using an open
frame power supply to power the product.
Failure to follow these instructions will result in death or
serious injury.
LOSS OF CONTROL
•
The designer of any control scheme must consider the
potential failure modes of control paths and, for certain
critical functions, provide a means to achieve a safe state
during and after a path failure. Examples of critical control
functions are emergency stop, overtravel stop, power outage and restart.
•
Separate or redundant control paths must be provided for
critical functions.
•
System control paths may include communication links.
Consideration must be given to the implication of unanticipated transmission delays or failures of the link.
•
Observe all accident prevention regulations and local
safety guidelines. 1)
•
Each implementation of the product must be individually
and thoroughly tested for proper operation before being
placed into service.
Revision R062812
Failure to follow these instructions can result in death or
serious injury.
1) For USA: Additional information, refer to NEMA ICS 1.1 (latest edition), “Safety
Guidelines for the Application, Installation, and Maintenance of Solid State Control”
and to NEMA ICS 7.1 (latest edition), “Safety Standards for Construction and Guide
for Selection, Installation and Operation of Adjustable-Speed Drive Systems”.
2-3
2 Safety
MCode Programming and Software Reference
MOVEMENT ON POWER APPLICATION
Hybrid Motion Technology’s functionality requires that the rotor
and stator of the motor be in precise alignment. To accomplish
this, the product will perform an initial calibration move upon
power up consisting of a 6 motor full step (10.8°) move in the
clockwise direction, followed by a 3 motor full step (5.4°) move
inthe counter-clockwise direction.
• Only power the system if there are no persons in the hazardous area.
Failure to follow these instructions can result in injury or
equipment damage.
HOT PLUGGING!
Do not connect or disconnect power, logic, or communications
while the device is in a powered state.
Remove DC power by powering down at the AC side of the DC
power supply.
Revision R062812
Failure to follow these instructions can result in equipment
damage.
2-4
MCode Programming and Software Reference
3
3 Intro to MCode
Introduction to MCode programming
This section will acquaint the user with basics of MCode programming
and the simple 1 and 2 character mnemonics which make up the MCode
programming language.
3.1

Operational modes.

Basic components of the MCode programming language.
Operational modes
There are two operational modes for the MCode compatible products:
Immediate and Program.
3.2
1)
Immediate: Commands are issued and executed directly to the
controller by user input into the terminal window.
2)
Program: Program Mode is used to input user programs into
the motion controller.
Basic components of MCode software
There are five basic components of the MCode Programming Language, they are:
3.2.1
1)
Instructions
2)
Variables
3)
Flags
4)
Keywords
5)
Math functions
Instructions
An instruction results in an action. There are four types of instructions:
Revision R062812
Motion
Motion instructions are those that result in the movement of a motor. The syntax for these commands is as follows: type the command followed by a space, and then the velocity or position data. For
example:MA 2000 will move the motor to an absolute position of 2000.
I/O
An I/O instruction results in the change of parameters or the state of
an input or output. The syntax for these commands are as follows: type
the command then an equal sign, then the data. Example: O2=0 will set
output 2 to 0.
Program
A program instruction allows program manipulation. The syntax of these
vary due to the nature of the command. Some command examples
would be: PG 100, which toggles the system into program mode starting
at address 100; BR LP, I1=1, which will branch to a program labeled LP
if input 1 is true.
3-1
3 Intro to MCode
MCode Programming and Software Reference
System
3.2.2
A system instruction is an instruction that can only be used in immediate
mode to perform a system operation such as program execution (EX)
or listing the contents of program memory (L). For example: EX 100 will
execute a program located at address 100 of program memory space,
or EX K1 will execute a program labeled K1.
Variables
A Variable is identified by a mnemonic and allows the user to define
or manipulate data. These can also be used with the math functions to
manipulate data. There are two classes of variables: factory-defined and
user-defined. There are 192 user program labels and variables available. The syntax for each variable may differ.
Factory defined variables
User defined variables
These variables are predefined at the factory. They cannot be deleted.
When an FD (Factory Default) instruction is given, these variables will
be reset to their factory default values. There are two types of factory
defined variables:

Read/Writable: These factory defined variables can have their
value altered by the user to affect events inside or outside of a
program. For example A (Acceleration variable) can be used to
set the Acceleration, or P (Position variable) can be used to set
the position counter.

Read Only: These factory defined variables cannot be changed
by the user. They contain data that can be viewed or used to affect events inside a program. For example, V (Velocity variable)
registers the current velocity of the motor in steps per second.
The VA instruction allows the user to create a 2 character name to a
user defined variable (32 bit value).
The restrictions for this command are:
1)
A variable cannot be named after an MCode Instruction, Variable or Flag.
2)
The first character must be alpha, the second character may be
alphanumeric.
3)
A variable is limited to two characters.
Revision R062812
With these the user can define a variable to store and retrieve data and
perform math functions. When the FD (Factory Defaults) instruction
is given, these variables will be deleted! There are two types of user
defined variables:
3-2
MCode Programming and Software Reference
3.2.3
3 Intro to MCode

Global variables: global variables are variables that are defined
outside of a program. The benefit to using a global variable is
that no user program memory is required. For example, the user
can define a variable called SP for speed by entering VA SP into
the terminal. The user can then set that variable equal to the
value of a read only variable V (velocity) by entering SP = V into
the terminal.

Local variables: this type of user defined variable is defined
within a program and can only affect events within that program.
It is stored in RAM. Note a local variable is not static, but is
erased and declared again each time a program is executed.
Flags
Flags show the status of an event or condition. A flag will only have one
of two possible states: either 1 or 0. Unlike variables, there are only factory defined flags.
Factory defined flags
3.2.4
Factory defined flags are predefined at the factory and cannot be deleted. When a FD (Factory Defaults) instruction is given, these flags will
be returned to their factory default state. There are two types of factory
defined flags:

Read/Writable: This type of flag is user alterable. They are
typically used to set a condition or mode of operation for device.
For example EE = 1 would enable encoder operation, or EE = 0
would disable the encoder functions.

Read Only: Read Only flags cannot be changed by the user.
They only give the status of an event or condition. Typically this
type of flag would be used in a program in conjunction with the
BR (Branch Instruction) to generate an if/then event based upon
a condition. For example the following line of code in a program
BR SP, MV = 0 would cause a program to branch to a subroutine named “SP” when the MV, the read only moving flag, is
false.
Keywords
Revision R062812
Keywords are used in conjunction with the PR and IP instructions to
indicate or control variables and flags. For instance, PR UV would print
the state of all the user-defined variables to the screen. IP would restore
all the factory variables from the NVM.
3-3
3 Intro to MCode
3.2.5
MCode Programming and Software Reference
Math functions
Math functions are used to perform various arithmetic functions on numeric data stored in registers or variables. Supported functions are +, -,
x, ÷, >, <, =, <=, >=, <>, AND, OR, XOR, NOT.
Example
Addition ...........................................K2†=P+R2
Subtraction .......................................K3†=R1-P
Multiplication .......................................... A=A*2
Division .................................................. A=A/2
†User-defined variable used as an example.
3.3
Program structuring
Proper structuring of your MCode program will ensure your ability to
work efficiently and will aid in trouble shooting your program. The figure
below illustrates how your program can be blocked out to group the
global system declarations, the main program body and the subroutines.
‘System configuration
S1=0,0
Ms=256
A=1000000
D=A
Hc=2
Rc=75
P=0
’Main program
PG 1
LB aa
P=0
LB a1
CL bb, I1-1
H 10
BR a1
Block 2: Main program
The first line places the device in program
mode starting at adress 1. This will contain
the main program label, as well as trigger
events which will call subroutines to perform
some action.
‘Subroutine from
“trigger event
LB bb
MA 51200
H
MA 0
H
RT
Block 3: Subroutines
Subroutines are called from the main program
block based upon a condirion such as an input
state, a trip, or a numeric value stored in a
register orvariable. They may also be called
unconditionally.
E
PG
Revision R062812
Block 1: System configuration
Contains the variables and flag that define
the operating parameters of the device
during the execution of the program.
Block 4: End program
E - designates the end of the program
PG - exits program mode
Figure 3.1 Recommended MCode program structure
3-4
MCode Programming and Software Reference
3.3.1
3 Intro to MCode
Programming aids
IMS Terminal
One of the most powerful tools available to you is the IMS Terminal
software. IMS Terminal is an integrated Terminal and Program Text editor. The text editor will automatically color-code the Variables, Flags and
Instructions that make up your program, as well as automatically indent
program blocks for easy visual identification of your program elements.
The IMS Terminal also has several features that assist in program
troubleshooting.
For more information on IMS Terminal see Section 6 Installing and Using IMS Terminal.
User Labels
The MCode programming language allows for 192 user labels for your
programs, subroutines, and user variables and flags. A label consists
of 2 characters, the first of which must be a letter, the second may be
alphanumeric. A label cannot use the same character combination as
any of the mnemonics used in the MCode programming language.
For purpose of this manual we have used the following example labels
because the beginning alpha character is not used in any instruction set
mnemonic:
Program label (G) ...............Example: G1, G8, Ga
Subroutine label (K) ............ Example: K7, K2, Ks
User variable label (Q) ....... Example: Q3, Q9, Qz
Example labeling
VA Q1
‘Create user variable Q1
PG 100
‘Enter Program mode
LB G1
‘Label Program G1
CL K1, I2=1
‘Call Subroutine K1 if Input 2 is HIGH
BR G1
‘Unconditional Branch to G1
K1
Comments
‘Declare Subroutine K1
MCode allows for comments to be inserted in your program code. The
comment character for the MCode language is the Apostrophe (‘). The
device will ignore the text string following the apostrophe. Please note
that the maximum length of a single line of program code is 64 characters, this includes program text, spaces and comments.
Using comments will be of assistance in trouble shooting your program.
Revision R062812
Programming reference
Another powerful tool is this manual. Section 3 contains detailed explanations and usage examples of each mnemonic in the MCode Programming Language. In Section 8 there are a number of fully commented
example programs that can be used to learn the basics of programming
and using the various functions of your MCode compatible device.
3-5
3 Intro to MCode
MCode Programming and Software Reference
3.4
Commonly used variables and instructions
3.4.1
Variables
MS (Microstep resolution)
P (Position)
VI (Initial velocity)
Revision R062812
VM (Maximum velocity)
3-6
MS (Microsteps Select) defines the resolution of the stepping motor.

A motor rotates 1.8° per step or 200 steps per revolution.

The MS selection divides the number of steps to yield a finer
resolution.

An MS value of 256 x 200 would yield 51200 microsteps per
revolution. (Each Motor step will be divided into 256 Microsteps.)

The MS default is 256.

To read the MS value, type PR MS and press enter

To write the MS value, type MS=<number> and press enter

As we continue you will see that all motion variables use this
value.
P indicates the position in either steps or encoder counts depending
upon the enable/disable state of encoder functions.

P takes its reading from C1 (Counter 1) when encoder functions are disabled. The reading is taken from C2 (Counter 2)
when encoder functions are enabled.

To read the position, type PR P or PR C1/C2 then press enter

To zero the position, type P=0 then press enter
Initial velocity in steps per second. (step size is a function of the value
of MS).

To read the initial velocity, type PR VI then press enter

To write to the Initial velocity, type VI=<number> then press
enter

The VI default is 1000
Maximum or final velocity in steps per second. (Step size is a function
of the value of ms).

To read the final velocity, type PR VM then press enter

To write to the final velocity, type VM=<number> then press
enter

The default VM Value is 768000
MCode Programming and Software Reference
A (Acceleration)
D (Deceleration)
3.4.2
3 Intro to MCode
Acceleration in steps per second2. (Steps per second, per second.)

The velocity of the motor will increase by the value of the acceleration rate every second until it reaches the programmed
velocity in SL mode or it reaches VM.

To read the acceleration, type PR A then press enter

To write to the acceleration, type A=<number> then press enter

The Acceleration Default value is 1000000
Deceleration in steps per second2. (Steps per second, per second.)

The velocity of the motor will decrease by the value of the
deceleration rate every second until it reaches the programmed
velocity in SL mode or it reaches VI.

To read the deceleration, type PR D then press enter

To write to the deceleration, type D=<number> then press enter

The deceleration default value is 1000000
Motion instructions
Motion instructions are those that cause the motors to move or affect
the movement of the motor. There are a few factors that must be considered when programming motion commands. Linear distances, number
of revolutions, degrees of rotation and timed moves can be calculated
and programmed from these factors.
MA (Move absolute)

All motion is programmed either microsteps per second or
(when the encoder is enabled) encoder counts (pulses) per
second.

All motion is directly affected by the motion command and the
program variables.

There are a number of factors impacting motion instructions.
These are addressed in detail in Section 7: Application and
programming notes.
Move to an absolute position relative to a defined zero position.
For example, type the following commands followed by pressing enter:
P=0
MA 20000
PR P
MA 3000
PR P
‘set the current position to 0 (zero)
‘move 20000 steps from 0 in the plus direction
‘the terminal screen will read 20000
‘move 3000 steps from 0 in the plus direction
‘the terminal screen will read 3000
Revision R062812
Absolute moves are always relative to 0 (zero).
You may program moves in the minus direction by typing the minus sign
(-) before the value.
3-7
3 Intro to MCode
MCode Programming and Software Reference
MR (Move relative)
Move the number of steps programmed relative to current position.
For example, type the following commands followed by pressing enter:
P=0
MR 20000
PR P
MR 3000
PR P
‘set the current position to 0 (zero)
‘move 20000 steps from the current position in
‘the plus direction
‘the terminal screen will read 20000
‘move 3000 steps from the current position in
‘the plus direction
‘notice the position read is 23000 and not 300
0
Relative moves are cumulative and are either added to or subtracted
from the current position.
You may program moves in the minus direction by typing the minus sign
(-) before the value.
SL (Slew axis)
Move at a constant velocity.
SL 200000 ‘the motor moves at a constant velocity 200000
‘steps per second
H (Hold)

The slew command overrides the VM (maximum velocity) parameter.

The value of the slew command may be changed “on the fly”.

You may program moves in the minus direction by typing the
minus sign (-) before the value.
An H (hold command) should typically follow any MA or MR commands
in a program so that program execution is suspended until the motion is
complete.
Below is a usage example.
PG 100
LB M1
MR 20000
steps
H
MR -20000
H
E
PG
‘enter program mode at address 100
‘label program M1
‘set mode to relative, move relative 20000
‘hold until motion completes
‘move relative -20000 steps
‘hold until motion completes
‘end program
‘exit program mode
A delay time value (1 to 65000 milliseconds) may be programed with the
hold command.
Revision R062812
(Note: There are circumstances where you may not want to hold up
program execution.)
3-8
MCode Programming and Software Reference
3.4.3
3 Intro to MCode
I/O instructions
Not all I/O instructions appply to all MCode device models. See section
4: command details for device compatability.
S<1-4> <9-12> (Set I/O Point)
This command configures the Type and Active state of I/O points 1-4.

Using the PR command to read I/O parameters

Read I/O1 Setup – “PR S1”

Read I/O2 Setup – “PR S2”
Set IO 3 parameters – “S3=0,1” Sets IO3 as a General Purpose Input,
Active High
For example: To set I/O4 as a jog+ input, active low, sinking
S4 =7,0,0
I<1-4><9-12> (Read input state)
Used to read the state of an individual input.
PR I1 will read the state of input 1 and display it to the terminal window.
BR K5, I2=0 will branch to the program address labled K5 when Input 2
is LOW
IN (Read all inputs as decimal)
Used to read the decimal equivalent of the 8 bit binary number represented by all 8 inputs collectively. Note the Input 12 is the Most Significant Bit.
PR IN will print the decimal value of the inputs.
IN will only read inputs 1-4 on devices equipped with only the standard
I/O Set!
IL (Read inputs 1-4 as decimal)
Used to read the decimal equivalent of the 4 bit binary number represented by inputs 1 - 4 collectively. Note the input 4 is the most significant bit.
Pr il will print the decimal value of the standard input set.
IH (Read inputs 9-12 as decimal)
Used to read the decimal equivalent of the 4 bit binary number represented by inputs 9 - 12 collectively. Note the input 12 is the most
significant bit.
PR IH will print the decimal value of the enhanced input set.
0<1-4><9-12> (Set output state)
Used to set the state of an output.
O2=1 will set Output 2 TRUE
Revision R062812
O<9-12> are applicable to the enhanced I/O models only!
3-9
3 Intro to MCode
MCode Programming and Software Reference
OT (Set all outputs as BCD)
Used to set the 8 bit binary equivalent of the decimal number represented by all 8 outputs collectively. Note the output 12 is the most significant
bit.
OT=214 will set the outputs to 11010110
OT will only set outputs 1-4 on devices equipped with only the standard
I/O Set!
OL (Set outputs 1-4 as BCD)
Used to set the 4 bit binary equivalent of the decimal number represented by outputs 1 - 4 collectively. Note the output 4 is the most significant
bit.
OT=10 will set the standard outputs to 1010.
OH (Set outputs 9-12 as BCD)
Used to set the 4 bit binary equivalent of the decimal number represented by outputs 1 - 4 collectively. Note the output 12 is the most significant
bit.
Ot=13 will set the enhanced outputs to 1101.
3.4.4
System instructions
The following system instructions will be used frequently.
CP (Clear program memory)
The CP instruction is used to clear program memory space.
FD (Restore facory defaults)
The FD instruction is used to return the device to its factory default
state.
<esc> (Stop motion and program)
Revision R062812
<CTRL+C > (Reboot)
3-10
<esc>
The ESCAPE key will stop the user program and stop the motor with no decel rate.
<CTRL+C>
CTRL+C will reboot the unit. This includes reloading
of the programs stored in nonvolatile memory into RAM and executing
any programs residing at label SU (Start Up).
MCode Programming and Software Reference
3.4.5
3 Intro to MCode
Program instructions
PG (Begin program mode)
This instruction toggles the device into or out of program mode.
PG 200
xxxxx
xxxxx
xxxxx
PG
LB (Lablel program, subroutine or branch
process)
‘Switch to program mode at address 200
‘Program starting at address 200
‘
|
‘
|
‘Switch out of program mode
MCode also offers the user the convenience of naming programs, subroutines and processes to ease in branching from one part of a program
to another, or calling a subroutine.
These labels, once set, will act as pointers to locations in program
memory space.
The LB, or label instruction, allows the user to assign a 2 character
name to a program or branch process within a program or subroutine.
The restrictions for this command are:
1)
A label cannot be named after an instruction, variable or flag.
2)
The first character must be alpha, the second character may be
alpha-numeric.
3)
A label is limited to to characters.
4)
A program labeled SU will run on power-up
Please Note: Any program labeled “SU” will execute on power-up.
PG 200
LB k1
xxxxx
xxxxx
PG
BR (Branch)
Used to branch conditionally or unconditionally to a routine.
PG 200
LB K1
xxxxx
xxxxx
xxxxx
BR K1
PG
Revision R062812
E (End program)
‘Switch to program mode at address 200
‘Label command will name the program K1
‘Program named by LB command xxxxx
‘
‘Switch out of program mode
‘Switch to program mode at address 200
‘Label command will name the program
‘Program named by LB command
‘Unconditional branch to Program Label K1
‘Switch out of program mode
Designates the end of a program.
PG 200
LB K1
xxxxx
xxxxx
xxxxx
BR K1
‘Switch to program mode at address 200
‘Label command will name the program
‘Program named by LB command
‘Unconditional branch to Program Label K1
3-11
3 Intro to MCode
MCode Programming and Software Reference
E
PG
H (Hold program execution)
Delays program execution in milliseconds.
PG 200
LB K1
xxxxx
xxxxx
xxxxx
H 2000
BR K1
E
PG
PR (Print)
‘End Program
‘Switch out of program mode
‘Switch to program mode at address 200
‘Label command will name the program
‘Program named by LB command
‘Hold 2 seconds before execution of program
‘Unconditional branch to Program Label K1
‘End Program
‘Switch out of program mode
Outputs specified text and parameter values to a terminal or terminal
software on a host PC.
PG 200
‘Switch to program mode at address 200
LB K1
‘Label command will name the program
xxxxx
xxxxx
‘Program named by LB command
xxxxx
H 2000
‘Hold 2 seconds before execution.
PR “Position =”, P
‘Print position
BR K1
‘Uncond branch to Program Label K1
E
‘End Program
PG
‘Switch out of program mode
VA (Create user variable)
Command used to define a user variable consisting of 2 alphanumeric
characters.
Revision R062812
PG 200
‘Switch to program mode at address 200
VA N1
‘Define user variable N1
LB K1
‘Label command will name the
program
xxxxx
xxxxx
‘Program named by LB command
xxxxx
H 2000
‘Hold 2 seconds before execution
PR “Position =”, P
‘Print position
BR K1, N1<10
‘Cond branch to K1 if N1 less than 10
E
‘End Program
PG
‘Switch out of program mode
3-12
MCode Programming and Software Reference
4
4 Command Summary
Command summary
MCode supports multiple families of motion control devices. Not all
instructions, variables and flags apply to all motion control products.
See the detailed descriptions for each command in Section 5 of this
document for device compatibility
Setup instructions, variables and flags
Mnemonic
Function
AL
Retrieve All Parameters
BD
Communications BAUD Rate
CE
Control C Software Reset
CK
Check Sum Enable
CM
CR
Unit
Range
Syntax Example
–
–
PR AL
BAUD
48, 96, 19,
38, 11
BD=<baud>
–
–
CE=<0/1>
–
–
CK=<1/0>
Clock Mode Enable
–
1/0
CM=<1/0>
Clock Mode Ratio
–
–
CR=1
CW
Clock Mode Output Step Width
–
0 to 255
CW=100
DE
Enable/Disable Drive
–
1/0
DE=<1/0>
DG
Disable Global Response
–
1/0
DG=<1/0>
DN
Device Name
Character
a–z, A–Z, 0–9
DN=<char>
EM
Echo Mode 0 (def)=Full Duplex,
1=Half Duplex
Mode
<0 to 3>
EM=<mode>
FD
Restore Factory Defaults
–
–
FD
IP
Initial Parameters from NVM
–
–
IP
PY
Enable/Disable Party Mode
Mode
1/0
PY=<mode>
QD
Queued
–
1/0
QD=<1/0>
UG
Upgrade Firmware
Code
2956102
IMS Term.
Upgrader
WT
Warning Temperature
Degrees C 0 to 84
WT=<0 – 84>
Revision R062812
4.1
4-1
4 Command Summary
Revision R062812
4.2
4-2
MCode Programming and Software Reference
Misc instructions, variables and flags
Mnemonic Function
Unit
Range
Syntax Example
AL
All Parameters, Used with PR
(Print)
–
–
PR AL
BY
BSY Flag 1=Prog. Running
–
0/1
PR BY
CM
Clock Mode
—
0/1
CM=1
CR
Clock Mode Ratio
–
–
CR=1
CW
Clock Mode Output Step Width
–
0 to 255
CW=100
EF
Error Flag
–
0/1
PR EF
ER
Error Number Variable
Number
–
PR ER
ES
Escape
–
–
ES=0
FD
Return to Factory Defaults
–
–
FD
IF
Input Variable Pending Flag
–
–
PR IF
IT
Internal Temperature
Degrees
Celsius
-55°C to
125°C
PR IT
IV
Input Into Variable
Number
–
IV <var>
PN
Part Number
–
–
PR “Position=”
PR
Print Selected Data and/or Text
–
–
PR <data/text
string>
R1
User Register 1
Number
Signed 32
bit
R1=<number>
R2
User Register 2
Number
Signed 32
bit
R2=<number>
R3
User Register 3
Number
Signed 32
bit
R3=<number>
R4
User Register 4
Number
Signed 32
bit
R4=<number>
SN
Serial Number
–
–
PR SN
VR
Firmware Version
Number
–
PR VR
UV
Read User Variables
–
–
PR UV
MCode Programming and Software Reference
Motion instructions, variables and flags
Mnemonic
Function
Unit
Range
Syntax Example
(–)
Do Previously Set Mode to/at
This Value
per mode
A
Set Acceleration
Steps/Sec2
1000000000
A=<accel>
D
Set Deceleration
Steps/Sec2
1000000000
D=<decel>
HC
Set Hold Current
% (Percent)
0 to 100
HC=<percent>
HT
Set Hold Current Delay Time
milliseconds
0–65000
HT=<msec>
JE
Jog Enable Flag
–
0/1
JE<0/1>
LM
Limit Stop Mode
–
1–6
LM=<number>
MA
Set Mode and Move to Abs.
Position
±Position
Signed 32 bit
MA <±pos>
MD
Motion Mode Setting
–
–
–
MR
Set Mode and Move to Relative
Position
±Distance
Signed 32 bit
MR <±dist>
MS
Set Microstep Resolution
Microsteps/
step
MSEL Table
MS=<param>
MT
Motor Settling Delay Time
milliseconds
0–65000
MT=<msec>
MV
Moving Flag
–
–
PR MV
NE
Numeric Enable
–
0/1
NE<0/1>
RC
Set Run Current
% (Percent)
1 to 100
RC=<percent>
SL
Set Mode and Slew Axis
Steps/sec
±5000000
SL <velocity>
V
Read Current Velocity
Steps/sec
±5000000
PR V
VC
Velocity Changing Flag
–
–
BR<addr>, VC
VI
Set Initial Velocity
Steps/sec
1–5000000
VI=<velocity>
VM
Set Maximum Velocity
Steps/sec
1–5000000
VM=<velocity>
–<number>
Revision R062812
4.3
4 Command Summary
4-3
4 Command Summary
Revision R062812
4.4
4-4
MCode Programming and Software Reference
Program instructions, variables and flags
Mnemonic
Function
Unit
Range
Syntax Example
BP
Break Point
–
–
BP <addr>,
<mode>
BR
Branch (Conditional/Unconditional)
–
–
BR <addr>,
<cond>
BY
Program Executing
–
–
PR BY
CL
Call Subroutine (Conditional/
Unconditional)
–
–
CL <addr>,
<cond>
CP
Clear Program
Address
1-767
CP <addr>
DC
Decrement Variable
–
–
DC <var/ureg>
E
End Program Execution
–
–
E
ES
Set Escape Mode
–
0–3
ES=<0–3>
EX
Execute Program at Address Using
Selected Trace Mode
1 to 767
EX <addr>,
<mode>
H
Hold Prog. Execution Blank/0=Motion
stops
milliseconds Blank(0)
1-65000
H=<msec>
IC
Increment Variable
–
–
IC <var>
L
List Program
Address
1-767
L <addr>
LB
Create a Program Address Label
Name
LK
Lock User Program
0/1
LK=<0/1>
OE
On Error Handler 0=Disabled
Address
0/1-767
OE <addr>
PG
Start Program Entry at Specified
Address
–
Blank/1-767
PG <addr>
PS
Pause Program Execution
–
–
PS
RT
Return from Subroutine
–
–
RT
RS
Resume Paused Program
–
–
RS
S
Save to NVM
–
–
S
SU
Start Program on Power On
–
–
LB SU
VA
Create A User Variable Name
Mnemonic
MCode Programming and Software Reference
Revision R062812
4.5
4 Command Summary
I/O instructions, variables and flags
Mnemonic
Function
Unit
Range
Syntax Example
D1
Set Input 1 Digital Filtering
Milliseconds
0–255
D1=<time>
D2
Set Input 2 Digital Filtering
Milliseconds
0–255
D2=<time>
D3
Set Input 3 Digital Filtering
Milliseconds
0–255
D3=<time>
D4
Set Input 4 Digital Filtering
Milliseconds
0–255
D4=<time>
D5
Set Input 5 Digital Filtering
Milliseconds
0–255
D5=<time>
D9 - D12
Input Switch Debounce
Milliseconds
0–255
D1=0
FC
Filter Capture
–
–
FC=3
FM
Filter Motion
–
–
FC=3
I1 -I4
Read Input 1-4
–
0/1
PR Ix, BR Ix,<cond>
I5
Read Input 5 (Analog)
–
0–1024
PR I5, BR I5,<cond>
I6
Read Encoder Index Mark Low
true
–
–
PR 16
I9 - I12
Read Input
–
–
PR 12
IL
Read Inputs 1–4 as One Value
data
0–15
PR IL
IH
Read Inputs 9 -12 as One Value data
0–15
PR IH
IN
Read Inputs 1–4 and 9-12 as
One Value
data
0–255
PR IN
IT
Internal Temperature
Degrees
Celsius
-55°C to
125°C
PR IT
O1-O4
Set Output x to Logic State
–
0/1
Ox=<1/0>
O9-O12
Set Output x to Logic State
–
0/1
Ox=<1/0>
OL
Write Data to Outputs 1–4 as
One Value
data
0–15
OL=<data>
OH
Write Data to Outputs 9–12 as
One Value
data
0–15
OT=<data>
OT
Write Data to Outputs 1–4 and
9-12 as One Value
data
0–255
OT=<data>
S1-S4
Setup IO Points 1-4
Type, Active
Type Table,
0/1
Sx=<type>,<active>
S9-S12
Setup IO Points 9-12
Type, Active
Type Table,
0/1
Sx=<type>,<active>
S5
Set/Print I/O Point 5
–
9 = 0 to +5 V
/ 10 = 4 to 20
mA
S5=<type>
S7 - S8
Setup I/O Point Type/Active
State
–
–
S7=34,0
S9 - S12
Setup I/O Point Type/Active
State
–
–
S9=2,0
S13
Setup I/O Point Type/Active
State
–
–
S13=60,0
TI
Trip on Input
–
–
TI <input>,<addr>
TE
Trip Enable
See Table
<1–4>
TE=<num>
4-5
4 Command Summary
4.6
Revision R062812
4.7
4-6
MCode Programming and Software Reference
Position related instructions, variables and flags
Mnemonic
Function
Unit
Range
Syntax Example
C1
Set Counter 1
Motor Counts
Signed 32
bit
C1=<counts>
HM
Home to Home Switch
Type
1 to 4
HM <type>
P
Set/Read Position
Motor/Encoder
Counts
Signed 32
bit
P=<counts>
PC
Read Captured Position at Trip
Motor/Encoder
Counts
Signed 32
bit
PR PC
TP
Trip on Position
Position
–
TP <pos>, <addr>
TE
Trip Enable
See Table
<0-3>
TE=<num>
Encoder related instructions, variables and flags
Mnemonic Function
Unit
Range
Syntax Example
C2
Set Counter 2
Encoder Counts
Signed 32
bit
C2=<counts>
DB
Set Encoder Deadband
Encoder Counts
0-65000
DB=<counts>
EE
Enable/Disable Encoder
Functions
–
1/0
EE=<1/0>
HI
Home to Encoder Index
Type
1 to 4
HI=<type>
I6
Read Encoder Index Mark
–
–
I6
PM
Position Maintenance Enable
Flag
0/1
PM=<0/1>
SF
Set Stall Factor
Encoder Counts
0-65000
SF=<counts>
SM
Set Stall Mode
0=Stop
1/0
Motor/1=Don’t Stop
SM=<mode>
ST
Stall Flag
–
PR ST
0/1
MCode Programming and Software Reference
4.8
4 Command Summary
Hybrid specific instructions, variables and flags
Mnemonic
AF
Function
Read Hybrid Status
Unit
—
Range
Syntax Example
128 bit binary
PR AF
BR <address>, AF=x
CL <address>, AF=x
0 = Off
1 = Fixed current (RC, HC)
AS
Set Hybrid mode
—
2 = Variable current (RC max)
(default)
AS=2
3 = Torque
0 = Hard Stop Tolerant
(fixed default)
CA
Set calibration mode
—
Second Parameter: Torque
compensation
CA=0,0
0 = Off (default)
1 = On
0 = 1.1 Full step (torque)
CB
Set control bounds
—
1 = 1.3 Full step
(default)
CB=2
2 = 1.5 Full step
3 = 1.7 Full step (speed)
CC
Set calibration current
%
1 to 100 (100 default)
CC=25
CF
Clear locked rotor fault
—
—
CF
CT
Set calibration time
mS
2 to 65535 (200 default)
CT=2000
EL
Remote encoder line
count
Lines
—
EL=512
LD
Set rotor lead limit
step
0 to 2147483647
(102400 default)
LD=256000
LL
Read position lead/lag
limit
steps
-2147483647 to +2147483647
PR LL
BR <address>, LL=x
CL <address>, LL=x
LG
Set rotor lag
step
0 to 2147483647
(102400 default)
LG=256000
LR
Locked rotor flag
—
0/1
LT
Set locked rotor timeout
mS
2 to 65535 (2000 default)
MF
Set make-up frequency
Hz
306 to 5000000 (768000 default)MF=51200
Revision R062812
LT=1000
4-7
4 Command Summary
MCode Programming and Software Reference
0 = Off (default)
1 = Use MF (make-up freq)
MU
Set make-up mode
—
2 = Use SS (system speed)
Clear parameter (not saved)
MU=1,1
1 = Use LL
2 = Clear LL
SC
Start calibration/
configuration test
—
SS
Set system speed
Steps/
sec
0 = Calibration
1 - Configuration test
38,910 — 5,000,000
SC=1
SS=50000
1 = Calibration done
2 = Hybrid active
TA
4 = Locked rotor
Trip on Hybrid status
TA=4,<address,label>
8 = Lag limit
16 = Lead limit
Set torque direction
TD
Revision R062812
4.9
4-8
—
0 = Minus
1 = Plus (default)
TD=1
TQ
Set torque percent
%
1 to 100 (25 default)
TQ-50
TS
Set torque mode speed
Steps/
sec
38,910 — 5,000,000
TS=50000
Math functions
Symbol
Function
+
Add Two Variables and/or Flags
-
Subtract Two Variables and/or Flags
*
Multiply Two Variables and/or Flags
/
Divide Two Variables and/or Flags
<>
Not Equal
=
Equal
<
Less Than
<=
Less Than and/or Equal
>
Greater Than
>=
Greater Than and/or Equal
&
AND (Bitwise)
|
OR (Bitwise)
^
XOR (Bitwise)
!
NOT (Bitwise)
5 MCode Command Details
MCode Programming and Software Reference
5
MCode command details
A (Acceleration)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
A
Function
Set acceleration
Type
Variable
Description
The A Variable sets the acceleration rate when changing
velocity in steps per second2. If the A was set at 76800 per
second2 the motor would accelerate at a rate of 76800 counts
per second, every second. If the maximum velocity was set at
768000 microsteps per second it would take 10 seconds to reach
maximum speed if VI=0.
Syntax
A=<mode>
Units
Steps/Sec2 (EE=0)/Counts/Sec2 (EE=1)
Range
91 to 1525878997 (Steps), 91 to 61035160 (Encoder Counts)
Default
Default: 1000000(EE=0), 40000 (EE=1)
Usage
Program/Immediate, Read/Write
Code Example
A=20000
‘Set Accel to 20000 steps/sec2
A=Q1
‘Set Accel to user var Q1
Related
D
Mnemonic
AL
Function
Retrieve all parameters
Type
Variable
AL (Retrieve all parameters)
Description
The AL variable is used with the PR (PRINT) instruction to print the
value/state of all variables and flags to the terminal program.
Syntax
PR AL
Usage
Immediate, Read
Code Example
PR AL
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-1
MCode Programming and Software Reference
5 MCode Command Details
AF (Hybrid flags)
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
5-2
Mnemonic
AF
Function
Read Hybrid status
Type
Read-only status flag
Description
The AF flag will print the status of the Hybrid logic.
Syntax
PR AF
BR <address/label>, AF=<condition>
CL <address/label>, AF=<condition>
Units
—
Range
128-bit binary
Conditions
1
Lead limit reached
2
Lag limit reached
4
Maximum lead/lag limit reached
8
Locked rotor
16
Hybrid mode is active
32
Hardware fault condition exists
64
At zero
128
Calibration is complete
256
Calibration fault
Notes
If multiple conditions exist the result is additive. i.e. At zero (64) and
Calibration complete (128) AF=192
Usage
Program/Immediate, Read only
Code Example
PR AF
‘print AF to the terminal
BR XY, AF=128 'branch to XY when calibration
'complete
Related
AS, TA
5 MCode Command Details
MCode Programming and Software Reference
AS (Hybrid mode)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
AS
Function
Set Hybrid operational mode
Type
Variable
Description
The AS variable will set the operating mode for the Hybrid motion
control device to one of four modes, which are detailed below.
These modes will determine the active state of the Hybrid circuitry
and the behavior characteristics of the MDrive Hybrid based upon
motor current or motor torque.
Syntax
AS=<mode>
Units
—
Range
0-3
Modes
0
Hybrid circuitry off.
1
Fixed current mode, motor current will be as specified by
the run current (RC) and hold current (HC) variables at the
speed specified by the system speed variable (SS).
2
Variable current mode, motor current will vary as needed
to move/position the load with a maximum current level
established by the run current (RC) variable..
3
Torque mode, motor torque and speed will vary as needed
to move/position the load at the maximum torque specified
by the set torque percent variable (TQ) at the maximum
speed as specified by the set torque speed variable (TS).
Default
2 (variable current mode)
Usage
Program/Immediate, Read/Write
Code Example
AS=1
Related
RC, HC, HT, TD, TQ, TS
Mnemonic
AT
Function
Reserved for internal use
Description
Reserved for internal use, will return an error if used.
‘set hybrid mode to fixed current
AT (Reserved)
Revision R062812
Do not use as a user variable, flag or program label.
5-3
MCode Programming and Software Reference
5 MCode Command Details
BD (Communications BAUD rate)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
BD
Function
Set communications BAUD rate
Type
Variable
Description
This variable sets the baud rate for serial communications with the
MCode device. It sets the rate for the RS-422/485 interface. The
baud rate is set by indicating the first two digits of the desired rate
as shown in the range section below.
In order for the new BAUD rate to take effect, the user must issue
the S (SAVE) instruction and then reset the device. When the
MCode device is reset, it will communicate at the new BAUD rate.
Syntax
BD=<mode>
Units
Bits/second
Range
48, 96, 19, 38, 11
Modes
48
4800 bps
96
9600 bps (default)
19
19200 bps
38
38400 bps
11
115200 bps - Not recommended for party mode
communications configurations.
Default
96 (9600 bps)
Usage
Program/Immediate, Read/Write
Code Example
BD=19
‘set BAUD rate to 19200 bps
S
‘save to NVM
Notes
If you change the Baud Rate in the MCode device it must be
matched in IMS Terminal.
A delay time between the command requests to the device must be
considered to allow it time to interpret a command and answer the
host before a subsequent command can be sent. The time between
requests is dependent on the command and the corresponding
response from the device.
Revision R062812
Related
5-4
CK
5 MCode Command Details
MCode Programming and Software Reference
BP (Break point)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
BP
Function
Set break point/execution mode
Type
Instruction
Description
The BP, or Break Point Instruction allows the user to set break
points within an MCode program to help in debugging the program.
To use the BP instruction the program must be executed in either
trace or single-step mode. The program will then run normally the
number of times specified by the count, then go into single-step
mode at the address or label specified by BP. Press the spacebar
to step through the program if in single step mode.
To disable the break point, set BP=0.
Syntax
BP <address/label>,<count>
Usage
Program/Immediate
Code Example
BP X1, 3
‘Break
EX P1, 1
or
EX P1,2
‘Execute
P1 in trace mode
‘Execute P1 in single step mode
EX
Revision R062812
Related
at label X1 after 3 cycles
5-5
MCode Programming and Software Reference
5 MCode Command Details
BR (Program branch)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
BR
Function
Conditional or unconditional program branch.
Type
Instruction
Description
The branch instruction can be used to perform a conditional or
unconditional branch to a routine in a MCode device program.
It can also be used to perform loops and IF THEN logic within a
program.
There are two parameters to a branch instruction. These are used
to perform two types of branches:
Conditional Branch
This type of branch first specifies an address or user label where
program execution should continue if the second parameter, the
condition, is true. The condition parameter may include flags
as well as logical functions that are to be evaluated. Only one
condition may exist.
Unconditional Branch
In this type of branch the second parameter is not specified, then
the execution will continue at the label or address specified by the
first parameter.
Syntax
BR <address/label>,<condition>
Usage
Program
Code Example
BR 256, I2=1
BR G1
BR G2, Q4<10
‘Cond. branch to address 256
‘if input 1 = ACTIVE
‘Unconditional branch to
‘program label G1
‘Cond branch to program G2 if
‘user var Q4 is less than 10
Related
EX
Mnemonic
BY
Function
Busy (program executing)
Type
Status flag
BY (Program executing)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-6
Description
The BY flag will indicate the status
of program execution,
Syntax
PR BY
Response
0 - No programs running, 1 - program executing
Default
0
Usage
Immediate, Read only
Code Example
PR BY
Related
PR
5 MCode Command Details
MCode Programming and Software Reference
C1 (Counter 1)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
C1
Function
Counter 1 (position counter)
Type
Variable
Description
This variable contains the count of the clock pulses generated
by the MCode compatible device. Counter 1 may be preset if
necessary
Syntax
C1=<steps>
Units
Motor steps
Range
-2147483648 to +2147483647
Default
0
Usage
Program/Immediate, Read/Write
Code Example
C1=20000
‘Set counter 1 to 20000 motor steps
PR C1
‘Print the value of C1 to the terminal screen
CL K5,C1>2100000 ‘Call subroutine K5 if C1>2100000
Related
C2, P
Mnemonic
C2
Function
Counter 2 (encoder counter)
Type
Variable
Description
This variable contains the encoder edge count received by the
MCode compatible device. Counter 1 may be preset if necessary
Syntax
C2=<counts>
Units
Encoder counts
Range
-2147483648 to +2147483647
Default
0
Usage
Program/Immediate, Read/Write
Code Example
C2=512
‘Set counter 2 to 512 counts
PR C2
‘Print the value of C2 to the terminal screen
CL K5,C2>2100000 ‘Call subroutine K5 if C2>2100000
Related
C1, P
C2 (Counter 2)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-7
MCode Programming and Software Reference
5 MCode Command Details
CA (Calibration mode - HW ver 1.8+)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
ASI Firmware > 4.0.07
HW version 1.8+
MOVEMENT ON POWER APPLICATION
Hybrid Motion Technology’s functionality requires that the rotor
and stator of the motor be in precise alignment. To accomplish
this, the product will perform an initial calibration move upon
power up consisting of a 6 motor full step (10.8°) move in the
clockwise direction, followed by a 3 motor full step (5.4°) move
inthe counter-clockwise direction.
• Only power the system if there are no persons in the hazardous area.
Revision R062812
Failure to follow these instructions can result in injury or
equipment damage.
Mnemonic
CA
Function
Set calibration mode
Type
Variable
Description
Hybrid logic requires a calibration to set the initial
relationship between the rotor and stator. A calibration
is performed on power up to bring the rotor into physical
alignment with the stator.
During calibration, the motor and position lag / lead logic is
cleared, and any incoming steps are ignored.
Calibration occurs automatically these conditions:
•
Power on
•
Reset
•
Hybrid functionality enabled
•
Bridge is re-enabled after being disabled
•
MSEL is changed.
•
A Clear Locked Rotor )CF) command is issued.
Syntax
CA=<0>,<method>
Units
—
Range
0
Modes
0
Hard Stop Tolerant (HST) See detailed description
Methods
0
Torque compensation off
1
Torque compensation on (not typically used for SSM
mode).
Default
0 (HST mode)
Usage
Program/Immediate, Read/Write
Code Example
CA=0,1
Notes
For MDrive Hybrid HW versions earliuer thatn 1.8, please
contact factory for support.
Related
CC, CT, SC
‘set torque compensation
Detailed HST description
The purpose of calibration is to bring the rotor and stator into alignment
which allows operation of the Hybrid Motion logic. The Hard Stop Tolerant (HST) calibration technique seeks to ensure proper alignment when
5-8
MCode Programming and Software Reference
5 MCode Command Details
the rotor is mechanically prohibited from movement by a hard stop or excessive stick/
slip.
HST tests for freedom of movement by attempting a 6 full step (10.8 deg) move in
the CW direction followed by a 3 full step (5.4 deg) move in the CCW direction. The
sequence proceeds as follows.
Pause for CT(Calibration Time) allowing system to settle.
•
•
•
•
•
Perform 6 full step CW move.
Wait for CT.
Perform 3 full step CCW move.
Pause for CT allowing rotor to settle
Set Calibration complete flag.
If motion is blocked the following occurs:
•
If the 1st move can not complete it is abandoned.
•
If the 2nd move can not complete it is abandoned then the sequence will be
restarted one time.
•
If neither move can be completed after 2 times through the sequence an error
109 will be generated, the calibration complete flag will set, and the bridges
will be disabled (a locked rotor response).
•
To correct, ensure that the motor shaft is free to in both directions. Torque
compensation mode may be used for high inertia loads. Calibration current my
be increased as well.
Calibration time and distance required when the motor is free to move in both
directions.
•
•
The time required typically is 3.12 seconds when CT is 250 mS. This value
of CT gives the best compromise between time and proper calibration.
Motor position will be advanced 3 full steps CW from initial position after
calibration is complete. Motor position can be confirmed using the encoder
counter C2. The step counter C1 does not count calibration steps
Calibration time and distance when motor is blocked.
•
•
•
The time will vary significantly based on where in the motion and which motion
is blocked. When the motor can not move at all in either direction the failure
will typically indicate in 10 seconds.
The motor position will also vary significantly based on which motion is effected and where within the motion.
The motor position can be determined using the encoder counter C2. The
step counter C1 does not count calibration steps.
The following indicate when calibration is complete.
Revision R062812
•
•
•
•
On power up, calibration is complete when the sign on message is sent.
The flag register AF can be polled for the Calibration Complete flag.
The trip on flag capability (TA to define, TE to enable) can be used also.
The flags are useful after a manually initiated calibration.
For mechanical systems with a large amount of prevailing torque a secondary
calibration step is available, Torque Compensation (CA=0,1).
•
•
Th process measures and compensates for the prevailing torque.
This typically adds 50 mS to the total calibration time and 1 encoder edge of
movement
5-9
MCode Programming and Software Reference
5 MCode Command Details
CB (Control bounds)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
CB
Function
Set control bounds
Type
Variable
Description
There are four limits, or control bounds that can be selected.
They are 1.1, 1.3, 1.5 and 1.7 full motor steps. Bounds of 1.1
will produce greater torque performance, though maximum
speed will be reduced. Bounds of 1.7 will produce greater
speed performance, though transient response is decreased.
Best overall torque-speed performance is achieved with
bounds set at 1.3 or 1.5.
Syntax
CB=<bounds>
Units
full motor step
Range
0—3
Bounds
0
1.1 full motor steps — best torque performance
1
1.3 full motor steps
2
1.5 full motor steps
3
1.7 full motor steps — best speed performance
best overall performance
Default
1 (1.3 full motor steps)
Usage
Program/Immediate, Read/Write
Code Example
CB=2
Notes
For torque mode operation the bounds are preset.
‘set control bounds to 1.5 steps
Related
CC (Calibration current)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
CC
Function
Set calibration current
Type
Variable
Revision R062812
Description
5-10
Syntax
CC=<percent>
Units
Percent
Range
1 — 100
Default
100%
Usage
Program/Immediate, Read/Write
Code Example
CC=25
Related
CA, CT
‘set calibration current to 25%
5 MCode Command Details
MCode Programming and Software Reference
CE (Software reset enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
CE
Function
Software reset enable (CTRL+C)
Type
Setup flag
Description
This setup flag will configure the device to respond or not respond
to a CTRL+C software reset.
Syntax
CE=<mode>
Range
0-2
Modes
0
Disables CTRL+C response
1
Enables CTRL+C response (default)
2
Is addressable in party mode (PY=1), CTRL+C will
respo0nd the same as CE=1 when not in party mode.
Default
1
Usage
Program,/Immediate, Read/Write
Code Example
CE=0
‘disable CTRL+C response
CF (Clear locked rotor fault)
Mnemonic
CF
Function
Clear locked rotor flault
Type
Instruction
CCWDescription
The CF instruction will clear a locked rotor fault, re-enable
the output bridge and initiate a Hard Stop tolerant calibration,
resulting in motion (10.8°then 5.4° CCW)
Syntax
CF
Usage
Program/Immediate, Read/Write
Code Example
CF
Related
CA, CT, LR
‘clear locked rotor fault
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
5-11
MCode Programming and Software Reference
5 MCode Command Details
CK (Checksum enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
CK
Function
Check sum enable
Type
Flag
Description
This setup flag will configure the device operate in check sum
mode where a check sum is required following the command.
Syntax
CK=<mode>
Range
0-2
Modes
0
Checksum mode disabled (default)
1
Puts the device into Check Sum Mode. When enabled,
all communications with the device require a Check
Sum to follow the commands. The Check Sum is the 2’s
complement of the 7 bit sum of the ASCII value of all
the characters in the command “OR”ed with 128 (hex =
0x80). The command will be acknowledged with a NAK
(0x15) if the Check Sum is incorrect or an ACK (0x06)
when the command is correctly processed (no error).
2
CK=2 will enable check sum mode, however NAK only
sent for bad check sum. “ACK” is not echoed if a program
is running. Only a NAK is echoed if an error occurs.
In immediate mode both ACK or NAK characters are
echoed.
Default
0
Usage
Program,/Immediate, Read/Write
Revision R062812
Code Example
5-12
MR 1
77 82 32 49
4D 52 20 31
77 + 82 + 32 + 49 = 240
1111 0000 240
0000 1111
0001 0000
1000 0000
1001 0000 144
‘MCode Command
‘Decimal Value
‘Hex
‘Add decimal values together
‘Change 240 decimal to binary
‘1’s complement
‘Add 1 (results in the 2’s
‘complement)
‘OR result with 128
‘result Check Sum value in
‘decimal
Notes
To Send the checksum, in IMS terminal use ALT+ Checksum (In
the example ALT+0144) The Response will be 06
Related
BD
5 MCode Command Details
MCode Programming and Software Reference
CL (Call subroutine)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
CL
Function
Call subroutine
Type
Instruction
Description
This function can be used to invoke a subroutine within a program.
This allows the user to segment code and call a subroutine from a
number of places rather than repeating code within a program.
There are two parameters to the CL instruction. The first specifies
the program address or label of the subroutine to be invoked if the
second parameter, the condition, is true. If the second parameter
is not specified, the subroutine specified by the first parameter is
always invoked. The condition parameter can include flags as well
as logical functions that are to be evaluated. There can only be
one condition.
The subroutine should end with a RT (Return) instruction. The
RT instruction will cause program execution to return to the line
following the CL instruction.
Syntax
CL=<address/label>,<condition>
Usage
Program,/Immediate, Read/Write
Code Example
CL 256, I5<512
‘Call Sub at 256, analog in < than 512
CL K5
‘Unconditional call to subroutine label K5
CL K8, I4=0
‘Call sub k8 if input 4 is INACTIVE
Notes
The called subroutine should end with a return command (RT)
Related
RT
CM (Clock mode enable)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MForce (Plus2 expanded features)
! WARNING
If CM=1 (Following Mode Enabled) Limit functions will not operate.
To overcome this limits must either be handled by the controlling electronics or the MCode compatible device can be programmed to Trip On Input
(See TI)
Revision R062812
Failure to follow these instructions can result in equipment damage.
Mnemonic
CM
Function
Clock mode enable
Type
Flag
Description
This flag (when CM=1) will enable the clock I/O 7 and 8. If
S7 and S8 are set as Input type, the device will be in follower
mode. If S7 and S8 are set as output types, signal will be
motor step counts out.
Syntax
CM=<0/1>
Range
0-1
Default
0
Usage
Program/Immediate, Read/Write
Code Example
CM=1
Related
S7, S8, CR, CW, FM
‘Enable Clock Mode
5-13
MCode Programming and Software Reference
5 MCode Command Details
CP (Clear program)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
CP
Function
Clear program
Type
Instruction
Description
This instruction will clear the program space in the NVM as
specified by the instruction parameter. Programs are stored
directly to the NVM and executed from there. Will clear
program addresses only. Will not clear globally declared user
variable or flags. FD will clear program memory as well.
Syntax
CP <address/label>
Usage
Immediate
Code Example
CP 256
CP G3
CP
Related
FD, IP
Mnemonic
CR
Function
Clock ratio
Type
Variable
Description
Clock Ratio value for electronic gearing. The value selected
will set the ratio from the clock input on I/O 7 (Step Clock)
and I/O 8 (Direction) to the drive output. A Clock Ratio set
to 0.50 will cause the frequency pulses sent to the driver
section of the device to be 0.50 of the frequency input to the
device, this would cause the device to “follow” at half the
velocity of the primary axis.
Syntax
CR <ratio>
Range
0.001 to 2.000
Default
1.000
Usage
Program/Immediate, Read/Write
Code Example
CR=1.500
Notes
A value of 1.00 has no acceleration or deceleration. All other
values use the value of A and D.
‘Clear prog. space beginning at addr. 256
‘Clear program space beginning at label G3
‘Clear all of program space
CR (Clock ratio)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MForce (Plus2 expanded features)
‘Ratio set to 1.5
The value of CR will have no impact on a clock output. CR
will impact Step/Direction in, Clock Up/ Clock Down in and
Quadrature in when I/O 7 and 8 are configured as inputs.
Revision R062812
Related
5-14
S7, S8, CM, CW
5 MCode Command Details
MCode Programming and Software Reference
CT (Calibration time)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
CT
Function
Set calibration time
Type
Variable
Description
The CT variable will set the calibration time in milliseconds.
Syntax
CT=<time>
Units
Milliseconds
Range
2 — 65535
Default
200 mS
Usage
Program/Immediate, Read/Write
Code Example
CT=1000
Related
CA, CC
Mnemonic
CW
Function
Set clock width
Type
Variable
Description
When CM=1 and I/O 7 and 8 are configured as outputs, CW
sets the pulse width of the output signal. The setting will be
a multiplier x 50 nS. CW will set the output clock pulse width
for: Step Clock out, Clock Up/Clock Down out, Quadrature
out and the Trip output (I/O 13).
Syntax
CW=<time>
Units
Nanoseconds
Range
0 - 255
Default
500 nS
Usage
Program/Immediate, Read/Write
Code Example
CW=100
Related
S7, S8, S13, CM, PC
‘set calibration time to 1S
CW (Clock width)
‘output step width to 5μS (100 x 50nS)
Revision R062812
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MForce (Plus2 expanded features)
5-15
MCode Programming and Software Reference
5 MCode Command Details
D (Deceleration)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
D
Function
Set deceleration
Type
Variable
Description
The D variable sets the deceleration of the device in steps
per second2. If the D was set at 76800 per second2 the
motor would decelerate at a rate of 76800 per second, every
second. If the device was running at a maximum velocity of
768000 microsteps per second it would take 10 seconds to
decelerate if VI=0.
Syntax
D=<steps/counts>
Units
Steps/Sec2 (EE=0)/Counts/Sec2 (EE=1)
Range
91 to 1525878997 (Steps EE=0),
91 to 61035160 (Counts EE=1)
Default
1000000(EE=0), 40000 (EE=1)
Usage
Program/Immediate, Read/Write
Code Example
D=20000
D=A
Related
A, C1, C2, P
Mnemonic
D1-D4
Function
Set input switch debounce
Type
Variable
Description
This variable will set the digital filtering to be applied to the
selected input 1 - 4. The input must be stable for “time”
amount of milliseconds before a change in state is detected.
Syntax
D1-4=<time>
Units
Milliseconds
Range
0 to 255
Default
0
‘set acceleration to 20000 step/sec2
‘set deceleration equal to acceleration
D1-D4 (Input switch debounce)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Usage
Program/Immediate, Read/Write
Code Example
D1=0
D1=150
Revision R062812
Related
5-16
I1 - I4
‘No debounce
‘Set filtering to 150 msec
5 MCode Command Details
MCode Programming and Software Reference
D5 (Analog input filter)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
D5
Function
Set analog input filter
Type
Variable
Description
D5 is a continuous filtering process. It does a running
average by computing:
(((X-1)/X)*current reading) + (1 / X) If X = 10, then: ((current
averaged value * 9)/10) + (new reading / 10) == NEW current
averaged value.
Syntax
D5=<X>
Units
Counts
Range
0 to 255
Default
0
Usage
Program/Immediate, Read/Write
Code Example
D5=0
D5=100
‘No debounce
‘Set filtering to 100 counts
D9-D12 (Input switch debounce)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MForce (Plus2 expanded features)
Mnemonic
D9-D12
Function
Set input switch debounce
Type
Variable
Description
This variable will set the digital filtering to be applied to the
selected input 9 - 12. The input must be stable for “time”
amount of milliseconds before a change in state is available.
Syntax
D9-12=<time>
Units
Milliseconds
Range
0 to 255
Default
0
Usage
Program/Immediate, Read/Write
Code Example
D10=0
D11=150
I9 - I12
Revision R062812
Related
‘No debounce on input 10
‘Set filtering to 150 msec on input 11
5-17
MCode Programming and Software Reference
5 MCode Command Details
DB (Encoder deadband)
Compatible with Motion Control products:
MDrive
MDrive (Ethernet)
MDrive (Plus2 expanded features)
MForce
MForce (Plus2 expanded features)
Mnemonic
DB
Function
Set encoder deadband
Type
Variable
Description
This variable defines the plus (+) and minus (-) length of the
encoder deadband in encoder counts.
When the encoder is enabled, a move is not completed until
motion stops within DB. If PM=1 device will correct if pushed
outside of DB value once in position.
Syntax
DB=<counts>
Units
Encoder counts
Range
0 to 65000
Default
1
Usage
Program/Immediate, Read/Write
Code Example
DB=10
Related
EE, C2, SF, SM, ST, PM, EL
Mnemonic
DC
Function
Decrement variable
Type
Instruction
Description
The DC instruction will decrement the specified variable by
one.
Syntax
DC <variable>
Usage
Program/Immediate, Read/Write
Code Example
DC R1
DC K5
Related
IC
‘Set encoder deadband to ±10 counts
DC (Decrement variable)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-18
‘Decrement register r1
‘Decrement user variable K5
5 MCode Command Details
MCode Programming and Software Reference
DE (Drive enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
DE
Function
Set drive enabled/disabled
Type
Variable
Description
The DE flag enables or disables the drive portion of the
MCode compatible device.
Syntax
DE=<0/1>
Range
0/1
States
0
Drive output bridge disabled.
1
Drive output bridge enabled (default).
Default
1
Usage
Program/Immediate, Read/Write
Code Example
DE=0
DE=1
Mnemonic
DG
Function
Enable/disable global response in party mode
Type
Flag
Description
The DG flag enables or disables device response to global
commands made while in Party Mode. In the default state
(DG=1) the device will not respond but will execute global
commands. By setting the the DG flag to 0, that device will
respond to global commands.
Syntax
DG=<0/1>
Range
0/1
States
0
Response to global commands enabled.
1
Response to global commands disabled (default).
‘Disable the motor driver section
‘Enable the motor driver section
DG (Disable global response)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Default
1 (disabled)
Usage
Program/Immediate, Read/Write
Code Example
DG=0
DG=1
Related
DN, PY
Revision R062812
‘Enable response to global commands
‘Disable Response to global commands no echo
5-19
MCode Programming and Software Reference
5 MCode Command Details
DN (Device name)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
DN
Function
Set device name for party mode.
Type
Variable
Description
DN sets the name of the device for party mode
communications. The acceptable range of characters is a-z,
A-Z, 0-9. The factory default is “!” Once named, the device
name must precede the instruction to that drive. When
assigning a device name, the character MUST be within
quotation marks.
The name is case sensitive. Refer to Section 2.2 in the
Hardware Reference for specific Party Mode configuration
and use instructions.
Once the default character has been changed it can not be
reset except on a FD (Factory Default Reset).
Syntax
DN=<"ascii character">
Units
ASCII Characters
Range
a-z, A-Z, 0-9
Default
!
Usage
Program/Immediate, Read/Write
Code Example
DN=”A”
DN=”65”
Notes
Note: Must enter S (Save) prior to any reset of the DN will be
lost.
Related
PY, S
Mnemonic
E
Function
End program
Type
Instruction
Description
Stops the execution of a program. Used in program mode to
designate the end of the program
Syntax
E
‘Set the device name to the character A
‘Set the device name to the character A*
E (End program)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-20
Usage
Program
Code Example
E
Related
PG, EX
‘End program
5 MCode Command Details
MCode Programming and Software Reference
EE (Encoder enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MForce
MForce (Plus2 expanded features)
Mnemonic
EE
Function
Enable/disable encoder
Type
Flag
Description
The EE flag enables or disables the optional encoder mode
of the MCode compatible device. When in Encoder Mode, all
moves are done by Encoder Counts. The 512 line Encoder
generates counts in a Quadrature format which results in
2048 counts per revolution.
Syntax
EE=<0/1>
Range
0/1
States
0
Disable the encoder (default state)
1
Enable the encoder
Default
0 (disabled)
Usage
Program/Immediate, Read/Write
Code Example
EE=0
EE=1
‘Disable the encoder
‘Enable encoder mode
Related
DB, C2, SF, SM, ST, PM, FM, EL
Mnemonic
EF
Function
Error condition exists
Type
Flag
Description
The Error flag will indicate whether or not an error condition
exists. It is automatically cleared when a new program is
executed. The only way to manually clear the EF flag is to
read the value of the ER variable or set ER=0.
EF (Error flag)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)\
MForce
MForce (Plus2 expanded features)
There is an instruction, OE, which allows the user to specify
the execution of a subroutine in the program memory when
an error occurs. The subroutine might contain instructions to
read the ER variable which would clear the EF flag.
Syntax
PR EF
Response
0/1
States
0
No error exists
1
Error condition exists
Revision R062812
Default
0 (disabled)
Usage
Program/Immediate, Read
Code Example
PR EF
Related
ER, OE
‘Read the state of the error flag
‘Response = 0: No error exists
‘Response = 1: Error condition exists,
'Error value exists
5-21
MCode Programming and Software Reference
5 MCode Command Details
EL (Remote encoder line count)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce (Plus2 expanded features)
Mnemonic
EL
Function
Set remote encoder line count.
Type
Variable
Description
This variable defines the number of encoder lines that the
device will see in a revolution. Counter 2 will read 4 x EL, or
4 counts per line.
Note : The setting for MS (Microstep Resolution) is relative to
the EL Setting. To calculate the minimum value for MS use
the following equation:
MS minimum = (EL x 8) ÷ 200
Example for 1000 line encoder: 1000 X 8 = 8000, 8000 ÷
200 = 40
Minimum Microstep Resolution = 50, or 10000 steps/rev.
Note: We recommend leaving the Microstep Resolution at
the default of 256.
Syntax
EL=<lines>
Units
Encoder lines
Default
512 (1000 for MDrive Hybrid)
Usage
Program/Immediate, Read/Write
Code Example
EL=1000
MS=50
Related
C2, MS, SF, SM, ST, PM, FM
Mnemonic
EM
Function
Set echo mode
Type
Flag
Description
The Echo Mode Flag will set the full/half duplex configuration
of the RS-485 channel.
Syntax
EM=<0-3>
Range
0-3
‘Config EL variable for 1000 line encoder
‘Config microstep res to 10000 steps/rev
EM (Echo mode)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
States
Revision R062812
Default
5-22
0
Echo all information back over communications line.
CR/LF indicates command accepted (full duplex)
(default).
1
Don’t echo the information, only send back prompt.
CR/LF indicates command accepted (half duplex).
2
Does not send prompt, only responds to PRINT (PR)
and LIST (L) commands.
3
Saves Echo in Print Queue then executes. Prints after
command is terminated.
0 (disabled)
Usage
Program/Immediate, Read
Code Example
EM=1
Related
ER, OE
‘Don’t echo the information,
5 MCode Command Details
MCode Programming and Software Reference
ER (Error)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
ER
Function
Display error code
Type
Variable
Description
The ER variable indicates the MCode device error code for
the most recent error that has occurred. The ER variable
must be read or set to zero to clear the EF flag.
A Question Mark <?> in place of the normal cursor indicates
an ERROR. A list of Error codes are located at the end of
this section..
Syntax
PR ER
Units
Numeric error code
Default
0
Usage
Program/Immediate, Read/Write
Code Example
PR ER
ER 0
Notes
Note: See Error code section for full listing of error codes.
Related
EF, OE
Mnemonic
ES
Function
Set escape mode
Type
Flag
Description
ESC flag to switch between ESC and CTRL+E. An Escape
will stop both the program and the motion.
Syntax
ES=<0-3>
Range
0-3
Modes
0
Escape Flag set to respond to CTRL+E
1
Escape Flag set to respond to ESC keypress (default)
2
Escape Flag set to respond addressable CTRL+E
(party mode)
3
Escape Flag set to respond to addressable ESC
keypress (party mode)
‘Read the error number, result = <Value>
‘Set the error value to zero
ES (Escape)
Default
1
Usage
Program/Immediate, Read/Write
Code Example
ESC=0
‘ESC responds to CTRL+E
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-23
MCode Programming and Software Reference
5 MCode Command Details
EX (Execute program)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
EX
Function
Execute program
Type
Instruction
Description
Execute program at a specified address or label using a
selected trace mode. Used in immediate mode.
There are three modes of program execution.
Syntax
Revision R062812
Modes
5-24
EX <address/label>,<mode>
0
Normal execution, is specified by a mode of 0 (or
simply leaving the mode blank).
1
Trace mode is specified by a mode of 1. This means
that the program executes continuously until the
program E is encountered, but the instructions are
“traced” to the communications port so the user can
see what instructions have been executed.
2
Single step mode is specified by a mode of 2. In this
mode, the user can step through the program using
the space bar to execute the next line of the program.
The program can be resumed at normal speed in this
mode by pressing the enter key.
Usage
Immediate
Code Example
EX 1
EX G2,1
EX 200,2
‘Execute program at address 1 normally
‘Execute program G2 in trace mode
‘Execute program at address 200 in
'single-step mode
5 MCode Command Details
MCode Programming and Software Reference
FC (Filter capture)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
FC
Function
Set filtering for the capture input.
Type
Variable
Description
This variable will set the digital filtering to be applied to I/O
13 when configured as a Capture input. The input must be
stable for “time” amount of milliseconds before a change in
state is detected.
Input 13 Filter Capture Settings
Range
Min Pulse
Cutoff Frequency
0
50 nS
10 MHz
1
150 nS
3.3 MHz
2
200 nS
2.5 MHz
3
300 nS
1.67 MHz
4
500 nS
1.0 MHz
5
900 nS
555 kHz
6
1.7 S
294.1 kHz
7
3.3 S
151 kHz
8
6.5 S
76.9 kHz
9
12.9 S
38.8 kHz
Syntax
FC=<0-9>
Range
0 to 9
Units
Numeric
Default
0 (min pulse 50 nS, cutoff of 10 MHz)
Usage
Program/Immediate, Read/Write
Code Example
FC=2
Related
I13, TC, S13
Revision R062812
‘Set filtering for Input 13 min pulse to 200
‘nS/CO 2.5 MHz
5-25
MCode Programming and Software Reference
5 MCode Command Details
FD (Restore factory defaults)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
FD
Function
Restore factory default settings
Type
Instruction
Description
FD will clear all program memory and return the MCode
compatible device to factory default settings. The response
will be the sign on message. FD will clear programs and
initialize parameters.
Syntax
FD <carriage return>
Usage
Immediate
Code Example
FD ‘Restore device to factory default state
Response “Copyright 2001-2007 by Intelligent Motion
Systems, Inc.”
Notes
FD will generate an error 73 if the unit is in motion.
Related
CP, IP
Mnemonic
FM
Function
Set filtering for the motion inputs.
Type
Variable
Description
Filter Motion inputs, I/O 7 & 8 for electronic gearing and
optional encoder.
FM (Filter motion)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MForce (Plus2 expanded features)
Revision R062812
Input 7 & 8 Filter Settings
5-26
Range
Min Pulse
Cutoff Frequency
0
50 nS
10 MHz
1
150 nS
3.3 MHz
2
200 nS
2.5 MHz
3
300 nS
1.67 MHz
4
500 nS
1.0 MHz
5
900 nS
555 kHz
6
1.7 S
294.1 kHz
7
3.3 S
151 kHz
8
6.5 S
76.9 kHz
9
12.9 S
38.8 kHz
Syntax
FM=<0-9>
Range
0 to 9
Units
Numeric
Default
Default: 2 (min pulse 200 nS, cutoff of 2.5 MHz)
Usage
Program/Immediate, Read/Write
Code Example
FM=3
Related
I7, I8, C2, EL, EE, S7, S8
‘Set filtering for motion min pulse to 300
‘nS/CO 1.67 MHz
5 MCode Command Details
MCode Programming and Software Reference
FT (Internal use only)
Mnemonic
FT
Function
Factory use only
Description
Will return an error if used. Do not use for a user program
label, variable or flag..
Mnemonic
H
Function
Hold program execution
Type
Instruction
Description
The hold instruction is used in a program to suspend
program execution. If no parameter is specified the execution
of the program will be suspended while motion is in progress.
This will typically be used following a MA, MR, HI or HM
instruction.
H (Hold program execution)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
A time in milliseconds may be placed as a parameter to the
hold instruction, This will suspend program execution for the
specified number of milliseconds.
Syntax
H <time>
Units
Milliseconds
Range
1 - 65000
Usage
Program/Immediate
Code Example
MA 1000
H
‘ Move Absolute 1000 steps
‘Suspend prog ex. until motion completes
‘(used after a move command)
H 2000
‘Suspend program execution for 2 seconds
PG, E, EX
Revision R062812
Related
5-27
MCode Programming and Software Reference
5 MCode Command Details
HC (Motor holding current)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
HC
Function
Motor holding current
Type
Variable
Description
This variable defines the motor holding current in percent.
HC=(%)
MDrive
MDrive
Hybrid
MForce
MicroDrive
(A RMS)
MForce
PowerDrive
(A RMS)
(All)
10
0.3
0.5
0.6
1.0
0.9
1.5
1.2
2.0
1.5
2.5
1.8*
3.0
2.1
3.5
2.4
4.0
90
2.7
4.5
100
3.0
5.0
20
MDrive Range
0 To 100%
30
40
50
60
70
Revision R062812
80
5-28
Actual Current
Not required
as Motor is
appropriately
sized to the
device.
Syntax
HC=<percent>
Units
Percent
Range
0 to 100
Default
5%
Usage
Program/Immediate, Read/Write
Code Example
HC=25
Related
RC, HT
'set holding current to 25%
5 MCode Command Details
MCode Programming and Software Reference
HI (Home to index mark)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
HI
Function
Home to index mark
Type
Instruction
Description
This instruction will find the the encoder index mark. There are four
combinations for this command. (See Use below.)
When HI is executed, the axis moves in the direction specified by
the (S) at VM until it reaches the index mark. It then creeps off of
the index in the direction specified by the sign of (C) at VI. Motion is
stopped as soon as the index changes state. Note that Speed and
Creep is set by the VM and VI commands.
1.
Speed: Specifies the direction and speed that the axis will
move until the switch is activated (VM).
2.
Creep: Specifies the direction and speed that the axis will
move off the switch until it becomes inactive again (VI).
Syntax
HI <type>
Range
1-4
Modes
1
Slew at VM in the minus direction and Creep at VI in the
plus direction.
2
Slew at VM in the minus direction and Creep at VI in the
minus direction.
3
Slew at VM in the plus direction and Creep at VI in the
minus direction.
4
Slew at VM in the plus direction and Creep at VI in the plus
direction.
Usage
Program/Immediate
Code Example
HI 2
Related
VM, VI, EE, I6, HM
Revision R062812
‘Slew at VM minus direction and Creep at VI in the
‘minus direction
5-29
MCode Programming and Software Reference
5 MCode Command Details
HM (Home to home switch)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
HM
Function
Home to home switch
Type
Instruction
Description
This instruction will find the selected I/O switch assigned to “Home”.
1.
Speed: Specifies the direction and speed that the axis will
move until the switch is activated (VM).
2.
Creep: Specifies the direction and speed that the axis will
move off the switch until it becomes inactive again (VI).
When HM is executed, the axis moves at VM in the direction
specified by the sign of speed. It then creeps off of the switch at VI
in the direction specified by the sign of creep. Motion is stopped
as soon as the switch becomes deactivated. Note that Speed and
Creep is set by the VM and VI commands.
The diagram on the following page illustrates the different scenarios
possible during the Homing (HM) sequence. The diagrams
represent the four HM commands. Below are the four combinations
of the HM command.
Syntax
HI <type>
Range
1-4
Revision R062812
Modes
5-30
1
Slew at VM in the minus direction and Creep at VI in the
plus direction.
2
Slew at VM in the minus direction and Creep at VI in the
minus direction.
3
Slew at VM in the plus direction and Creep at VI in the
minus direction.
4
Slew at VM in the plus direction and Creep at VI in the plus
direction.
Usage
Program/Immediate
Code Example
HM 2
Related
VM, VI, EE, I6, HI, LM, S<1-4>, <9-12>
‘Slew at VM minus direction and Creep at VI in the
‘minus direction
5 MCode Command Details
MCode Programming and Software Reference
The key to the diagrams is
as follows.
1.
2.
Slew at VM to find the
Index Mark.
Decelerate to zero (0)
after finding the Index
Mark.
3.
Creep at VI away
from the Index Mark.
4.
Stop when at the
edge of the Index
Mark.
Homing (HM) Function - Sequence of Events
Home Switch Range
Home Switch
True
1
Slew at VM to find Home Switch
False
2
Deceleration to zero (0) after finding the Home Switch
3
Creep at VI away from the Home Switch
4
Stop when at the edge of the Home Switch
H1: Slew – and Creep +
-VM
1
NOTE: MT, Motor Settling Delay Time is still in effect
2
-VI
Motion 0
+VI
4
2
3
Deceleration Rate too long.
Home Switch is overshot.
Motion must reverse to
find Home Switch and stop.
1
+VM
-VM
1
2
Motion
-VI
0
+VI
4
Deceleration Rate is short enough
so that motion can stop within
the range of the Home Switch.
3
+VM
H2: Slew – and Creep –
-VM
1
2
3
-VI
Motion 0
+VI
4
2
1
Deceleration Rate too long.
Home Switch is overshot.
Motion must reverse to
find Home Switch and stop.
+VM
-VM
1
2
3
-VI
Motion 0
+VI
Deceleration Rate is short enough
so that motion can stop within
the range of the Home Switch.
4
+VM
H3: Slew + and Creep –
-VM
Motion
3
-VI
0
+VI
+VM
Deceleration Rate is short enough
so that motion can stop within
the range of the Home Switch.
4
2
1
-VM
Motion
4
-VI
0
+VI
+VM
3
2
1
1
Deceleration Rate too long.
Home Switch is overshot.
Motion must reverse to
find Home Switch and stop.
2
H4: Slew + and Creep +
-VM
Motion
-VI
0
+VI
+VM
Deceleration Rate is short enough
so that motion can stop within
the range of the Home Switch.
4
1
3
2
-VM
Motion
+VM
1
2
-VI
0
+VI
4
3
1
Deceleration Rate too long.
Home Switch is overshot.
Motion must reverse to
find Home Switch and stop.
2
Revision R062812
Figure 5.1 Homing functions sequence of events
5-31
MCode Programming and Software Reference
5 MCode Command Details
HT (Hold current delay time)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
HT
Function
Holding current delay time
Type
Variable
Description
The HT variable sets the delay time in milliseconds between the
MV=0 and when the device shifts to the holding current level
specified by the HC (Motor Holding Current) variable. The delay
time is also effected by the MT (Motor Settling Delay Time) variable
in that the total time to current change is represented by the sum of
MT + HT. The total of MT+HT cannot add up to more than 65535,
thus the value of MT is included in the HT range.
Thus the Maximum setting for HT=(65535-MT). If HT=0, the
current will not reduce.
Syntax
HT=<time>
Units
Milliseconds
Range
0 or 2 - 65535
Default
500 ms
Usage
Program/Immediate. Read/Write
Code Example
HT=1500
Related
HC, MT, RC
‘set hold current delay time to 1.5 seconds
HT (Hold current delay time)
Compatible with Motion Control products:
MDrive Legacy
! CAUTION
The HT command functions differently on legacy MDrive products than
on current MDrive products in that if HT is set to 0, the current will reduce
immediately.
Failure to follow these instructions can result in equipment damage.
Mnemonic
HT
Function
Holding current delay time
Type
Variable
Description
The HT variable sets the delay time in milliseconds between the
MV=0 and when the device shifts to the holding current level
specified by the HC (Motor Holding Current) variable. The delay
time is also effected by the MT (Motor Settling Delay Time) variable
in that the total time to current change is represented by the sum of
MT + HT. The total of MT+HT cannot add up to more than 65535,
thus the value of MT is included in the HT range.
Revision R062812
Thus the Maximum setting for HT=(65535-MT). If HT=0, the
current will reduce. immediately.
5-32
Syntax
HT=<time>
Units
Milliseconds
Range
0 or 2 - 65535
Default
500 ms
Usage
Program/Immediate. Read/Write
Code Example
HT=1500
Related
HC, MT, RC
‘set hold current delay time to 1.5 seconds
5 MCode Command Details
MCode Programming and Software Reference
I1, I2, I3 and I4 (Read inputs 1, 2 ,3 or 4)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
I1 - I4
Function
Read the state of inputs 1 - 4
Type
Variable
Description
This variable will read the state of the specified input 1 - 4. Can
be used with PR (Print), BR (Branch) and CL (Call Subroutine)
instructions. Can also be used with R1 - R4 and User Variables.
The value of the bit state will be dependant on active (low/high)
state of the input, specified by the S<1-4> 2nd parameter.
Syntax
PR I<1-4>
BR <addr/lbl>, I<1-4>=<1/0>
CL<addr/lbl>, I<1-4>=<1/0>
Units
Logic 0 or 1
Range
0/1
Usage
Program/Immediate. Read
Code Example
PR I2
BR 128,I3=1
CL K9, I4=0
Related
IL, IN, O1-O4, S1-S4
Revision R062812
‘Prints the logic state of input 2
‘Cond branch to address 125, Input 3 ACTIVE
‘Call subroutine K9, Input 4 INACTIVE
5-33
MCode Programming and Software Reference
5 MCode Command Details
I5 (Read analog input)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
I5
Function
Read the value of the analog input
Type
Variable
Description
This variable will read the value of the correlating bit value seen on
the Analog Input. Can be used with PR (Print), BR (Branch) and CL
(Call Subroutine) instructions. The value read will between 0 and
1023.
This value represents a voltage or current being seen on the analog
input. for example, if in current mode (0 - 20mA range) 1023 would
represent 20 mA, 512 would represent 10 mA.
Syntax
PR I5
BR <addr/lbl>,I5=<0-1023>
CL<addr/lbl>, I5<0-1023>
Units
Numeric value
Range
0 to 1023
Usage
Program/Immediate. Read
Code Example
PR I5
‘Print the value of I5
BR G3,I5>512 ‘Branch to prog G3 if I5 is > 512
CL 423,I5<220 ‘Call sub at address 423 if I5 is < 220
Related
S5
Mnemonic
I6
Function
Read the state of the encoder index mark
Type
Variable
Description
This variable will read the on/off state of the Encoder Index Mark.
Can be used with PR (Print), BR (Branch) and CL (Call Subroutine)
instructions. The value read will be 0 (off mark) or 1 (on mark).
Syntax
PR I6
BR <addr/lbl>,I6=<0/1>
CL<addr/lbl>, I6<0/1>
Units
Logic state 0 or 1
Range
0/1
Usage
Program/Immediate. Read
Code Example
PR I6
BR 324,I6=1
CL K3,I6=1
Related
S5
Mnemonic
I7, I8
Function
Reserved, do not use as a user variable, flag or label.
I6 (Read encoder index mark)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
‘Print state of the encoder index mark
‘Branch to address 324 if I6 is ACTIVE
‘Call subroutine K3 if I6 is ACTIVE
I7, I8 (Reserved)
5-34
5 MCode Command Details
MCode Programming and Software Reference
I9, I10, I11 and I2 (Read inputs 9, 10, 11 or 12)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MForce (Plus2 expanded features)
Mnemonic
I9 - I12
Function
Read the state of inputs 9 - 12
Type
Variable
Description
This variable will read the state of the specified input 9 - 12. Can
be used with PR (Print), BR (Branch) and CL (Call Subroutine)
instructions. Can also be used with R1 - R4 and User Variables.
The value of the bit state will be dependant on active (low/high)
state of the input, specified by the S<9-12> 2nd parameter.
Syntax
PR I<9-12>
BR <addr/lbl>, I<9-12>=<1/0>
CL<addr/lbl>, I<9-12>=<1/0>
Units
Logic 0 or 1
Range
0/1
Usage
Program/Immediate. Read
Code Example
PR I12
BR 128,I9=1
CL K9, I8=0
Related
IL, IN, O1-O4, S1-S4
Mnemonic
I13
Function
Reserved, do not use as a user variable, flag or label.
‘Prints the logic state of input 12
‘Cond branch to address 125, Input 9 ACTIVE
‘Call subroutine K9, Input 8 INACTIVE
I13 (Reserved)
IC (Increment variable)
Mnemonic
IC
Function
Increment variable
Type
Instruction
Description
The IC instruction will increment the specified variable by
one.
Syntax
IC <variable>
Usage
Program/Immediate, Read/Write
Code Example
IC R1
IC K5
Related
DC
‘Increment register r1
‘Increment user variable K5
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-35
MCode Programming and Software Reference
5 MCode Command Details
IF (Input variable pending)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
IF
Function
Input variable pending
Type
Flag
Description
The IF instruction is automatically set to 1 when IV command
is executed. The IF flag reflects an input value from serial
port is pending, not that one has been received. IF will be
cleared to zero (0) with a carriage return or can be reset
manually.
Syntax
<user input><CR>
IF=<0/1>
States
0
No variable input pending
1
Variable input pending
Default
0
Usage
Program/Immediate, Read
Code Example
No Usage Example, Flag set automatically by IV
IL (Read inputs 1 - 4 as a group)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-36
Mnemonic
IL
Function
Read the state of inputs 1 - 4 as one value
Type
Variable
Description
This keyword will read the binary state of inputs 1-4 and print them
as a decimal value. When used thus, Input 1 is the Least Significant
Bit (LSb) and Input 4 is the Most Significant Bit (MSb). It may be
used in conjunction with the R1-R4 (Registers), PR (Print), BR
(Branch) and CL (Call Subroutine) instructions. The value is a
function of the actual voltage level of the I/O where 1 = +V and 0
= Ground. (Not a function of the active state defined in S1 to S4
variables).
Syntax
PR IL
BR <addr/lbl>,IL=<0-15>
CL<addr/lbl>, IL<0-15>
Units
Decimal
Range
0 —15
Usage
Program/Immediate. Read
Code Example
PR IL
BR 324,IL=8
CL K3,IL=13
Related
IH, IN, OL, OH, OT, S1-S4
‘Print decimal value of IO4-IO1
‘Branch to address 324 if IL=8
‘Call subroutine K3 if IL=13
5 MCode Command Details
MCode Programming and Software Reference
IH (Read inputs 9 - 12 as a group)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MForce (Plus2 expanded features)
Mnemonic
IH
Function
Read the state of inputs 9 - 12 as one value
Type
Variable
Description
This keyword will read the binary state of inputs 9-12 and print them
as a decimal value. When used thus, Input 9 is the Least Significant
Bit (LSb) and Input 12 is the Most Significant Bit (MSb). It may be
used in conjunction with the R1-R4 (Registers), PR (Print), BR
(Branch) and CL (Call Subroutine) instructions.
The value is a function of the actual state of the I/O where 1 = +V
and 0 = Ground. (Not a function of the active state defined in S9 to
S12 variables)
Syntax
PR IH
BR <addr/lbl>,IH=<0-15>
CL<addr/lbl>, IH<0-15>
Units
Decimal
Range
0 —15
Usage
Program/Immediate. Read
Code Example
PR IH
BR 324,IH=8
CL K3,IH=13
Related
IL, IN, OL, OH, OT, S1-S4, S9-S12
‘Print decimal value of IO12-IO9
‘Branch to address 324 if IH=8
‘Call subroutine K3 if IH=13
IN (Read inputs 1 - 4 and 9 - 12 as a group)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
IN
Function
Read the state of inputs 1 - 4 and 9 - 12 as one value
Type
Variable
Description
This keyword will read the binary state of inputs 1-4 and 9-12 and
print them as a decimal value. When used thus, Input 1 is the Least
Significant Bit (LSb) and Input 12 is the Most Significant Bit (MSb).
It may be used in conjunction with PR (Print), BR (Branch) and CL
(Call Subroutine) instructions.
Revision R062812
The value is a function of the actual state of the IO where 1 = +V
and 0 = Ground. (Not a function of the active state defined in S1 to
S4 and S9 to S12 variables). On Standard Plus Models IN will only
read the lower group (Inputs 1-4). The debounce function has no
effect on the data read.
Syntax
PR IN
BR <addr/lbl>,IN=<0-255>
CL <addr/lbl>, IN<0-255>
Units
Decimal
Range
0 —255
Usage
Program/Immediate. Read
Code Example
PR IN
BR 324,IN=225
CL K3,IN=113
Notes
While tailored to Mdrive and MForce models with 8 I/O points, this
command will function the same as IL on units with 4 I/O.
Related
IH, IL, OL, OH, OT, S1-S4, S9-S12
‘Print value of IO4-IO1 and IO9-IO12
‘Branch to address 324 if IN=225
‘Call subroutine K3 if IN=113
5-37
MCode Programming and Software Reference
5 MCode Command Details
IP (Initialize parameters)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
IP
Function
Initialize parameters
Type
Instruction
Description
The IP instruction will return all of the device variable and flag
parameters to their stored values.
If IP is used while the motor is moving an Error 74: Tried to
Initialize Parameters of Clear Program while moving will be
issued.
Syntax
IP
Usage
Program/Immediate
Code Example
IP
Related
S, FD
'initialize parameters
IT (Read internal temperature)
Revision R062812
Compatible with Motion Control products:
MDrive 34 DC and AC
MDrive 34 (Plus2) DC and AC
MDrive Hybrid
MForce PowerDrive
MForce (Plus2) PowerDrive
5-38
Mnemonic
IT
Function
Read the internal temperature of the device
Type
Variable
Description
Internal Temperature of the MCode compatible driver electronics.
Only used on MDrive 34, AC input MDrive, MForce PowerDrive and
MDrive Hybrid.
Syntax
PR IT
Units
Degrees
Range
-55°C to 125°C
Usage
Program/Immediate. Read
Code Example
PR IT ‘Print the internal temperature to the terminal screen
Related
WT
5 MCode Command Details
MCode Programming and Software Reference
IV (Input to variable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
IV
Function
Input data into variable
Type
Instruction
Description
With the IV command, a user may input new variable values.
These values must be numeric and will be input into the
variable specified in the IV command.
The variable used for the IV may be a system or USER
Variable. A USER Variable must be declared prior to the IV
command.
When waiting for user input, there must be a conditional
program loop based upon the state of IF (Input Pending)
until the variable is input by the user.
Syntax
IV <user variable/R1-R4>
Usage
Program/Immediate
Code Example
IV R1
VA K5
IV K5
‘Input data into R1
‘Create user variable K5
‘Input data into user variable K5
IV R1
‘input value into register 1
LB k1
‘label program loop k1
BR k1,If=1 ‘branch to k1 awaiting user input
Related
IF
Mnemonic
JE
Function
Enable/disable jog functions
Type
Flag
Description
This command will enable Jog Mode if I/O are set for Jog
Plus and/or Jog Minus.
Syntax
JE=<0/1>
States
0
Jog functions disabled
1
Jog functions enabled
JE (Jog enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Default
0
Usage
Program/Immediate, Read/Write
Code Example
JE=0
JE=1
Revision R062812
‘Disable Jog mode
‘Enable Jog mode
5-39
MCode Programming and Software Reference
5 MCode Command Details
L (List program space)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
L
Function
List contents of program space
Type
Instruction
Description
The L instruction will print the contents of program space
beginning at the specified address to the end. If no address
is specified it will list beginning at address 1.
Syntax
L <address/label>
Usage
Immediate
Code Example
L ‘List program space contents from address 1
L G5
‘List program space contents from label G5
Related
CP, FD
LB (Label program or subroutine)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
LB
Function
Label program or subroutine
Type
Instruction
Description
The LB, or Label Instruction, allows the user to assign a 2
character name to a program, (BR) branch process or (CL)
call subroutine. There is a limit of 192 labels.
The restrictions for this command are:
Syntax
Revision R062812
A label cannot be named after an MCode Instruction,
Variable or Flag or Keyword.
2.
The first character must be alpha, the second
character may be alpha-numeric.
3.
A label is limited to two characters.
4.
A program labeled SU will run on power-up
5.
Labels ARE NOT case sensitive.
LB <label>
Usage
Program
Code Example
PG 100
LB G1
‘Start Program at address 100
‘Name program G1
PG 1
LB SU
‘Label Program to execute on power up.
Related
5-40
1.
BR, CL, EX, TI, TP, L, CP
5 MCode Command Details
MCode Programming and Software Reference
LD (Lead limits)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
LD
Function
Set rotor lead limit
Type
Variable
Description
LD will set the lead limit in motor steps.
Syntax
LD=<steps>
Units
steps
Range
0 — 2147483647
Default
102400
Usage
Program/Immediate, Read/Write
Code Example
LD=52100
Notes
When the lead limit is reached, error 106, lead limit reached
will be active
Related
LG, LL
Mnemonic
LG
Function
Set rotor lag limit
Type
Variable
Description
LD will set the lag limit in motor steps.
Syntax
LG=<steps>
Units
steps
Range
0 — 2147483647
Default
102400
‘set lead limit to 52100
LG (Lag limits)
Usage
Program/Immediate, Read/Write
Code Example
LG=52100
Notes
When the lag limit is reached, error 107, lag limit reached will
be active
Related
LD, LL
‘set lag limit to 52100
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
5-41
MCode Programming and Software Reference
5 MCode Command Details
LL (Position lead/lag)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
LL
Function
Read rotor lead/lag
Type
Variable
Description
Represent the number of counts that the rotor leads or lags
the stator.
A positive value indicates position lag. A negative value
indicates position lead
Syntax
PR LL
CL <address/label>, LL <condition><steps>
BR <address/label>, LL <condition><steps>
Units
steps
Range
-2147483647 to +2147483647
Usage
Program/Immediate, Read only
Code Example
PR LL
‘read rotor lead/lag
CL k5, LL>102500 ‘Call subroutine k5 if
‘LL is greater than
‘102500 steps
Related
LD, LG
Mnemonic
LK
Function
Lock access to user program space
Type
Flag
Description
This flag allows the user to lock the program from being
listed or modified. It can only be reset by clearing the entire
program space: CP (no address). If CP (address,/label), L
(address/label) or PG (address/label) are entered, then error
44 (Program Locked) will be set and nothing else will happen.
LK (Lock user program)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Revision R062812
To clear LK, don’t save (S) then do a Ctrl-C or Cycle Power
and the LK will be reset to previous unlocked state. (Program
is automatically stored in NVM as it is entered.) Or you may
clear program (CP or FD to list or reprogram the device.).
This will clear the program and reset LK to 0
5-42
Syntax
LK=<0/1>
States
0
User programs may be modified or listed
1
User programs may not be modified or listed
Default
0 (disabled)_
Usage
Immediate, Read/Write
Code Example
LK=1
‘Lock programs from being listed or changed
5 MCode Command Details
MCode Programming and Software Reference
LM (Limit stop modes)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
LM
Function
Limit stop modes
Type
Variable
Description
The LM variable specifies the Limit Stop Mode for the MCode
compatible device. There are six LM modes.
Syntax
LM=<mode>
Range
1-6
Modes
1
Normal Limit function with a decel ramp.
The I/O must be set for Limits (S1-S4, S9-S12 Command).
If the limit switch in the direction of travel is reached, the
motion will decel to a stop. That is, the plus limit works only
in the plus direction of travel and the minus limit works only
in the minus direction of travel.
In Figure 5.2, the Limit is activated at a given position but
because of the deceleration rate the motion continues for
the duration of the deceleration time. This position may be
beyond the trip point of the limit and a subsequent move in
the same direction will not stop. A crash may be imminent.
If the limit is activated and maintained the software will allow
motion only in the opposite direction.
If Homing (HM) is active and a limit is reached, the motion
will decel to a stop and then reverse direction and seek the
Homing Switch. If the Homing Switch is not activated on the
reverse and the opposite limit is reached all motion will stop
with a decel ramp. (See HM)
2
A Limit stops all motion with a deceleration ramp including
Homing.
3
A Limit will stop all motion with a deceleration ramp and
stop program execution.
4
Functions as LM=1 but with no deceleration ramp
5
Functions as LM=2 but with no deceleration ramp.
6
Functions as LM=3 but with no deceleration ramp.
Usage
Program/Immediate, Read/Write
Code Example
LM=2
Related
H,I, HM, JE, MA, MR, SL
‘Set Limit stop with a decel ramp, no homing.
Home
Switch
Minus
Limit
Plus
Limit
Minus Direction
Revision R062812
Plus Direction
Switch Trip Point
(Switch Closed)
Actual Stop Position
Because of Decel Rate
(Switch Open)
Distance Relative
to Velocity and Decel Rate
Figure 5.2 Limit modes of operation
5-43
MCode Programming and Software Reference
5 MCode Command Details
LR (Locked rotor)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
A locked rotor is defined as no rotor movement while at the maximum allowed lag for
a specified period of time. When lag becomes equal to the bounds, a timer starts to
count down. Upon reaching zero, a locked rotor will be indicated by the assertion of a
status flag. The timer reloads on any encoder movement. The timer timeout period is
user selectable from 2mS to 65.5 seconds.
When Hybrid is configured AS=1 or 2, a locked rotor will also cause an internal fault
(LR) disabling the output bridge. The bridges may be re-enabled by cycling power,
cycling the enable input, or via software command.
In torque mode, a locked rotor does not disable the bridges. The locked rotor flag
(LR) can be used to indicate the rotor has been stopped at the specified torque for a
preset amount of time.
Mnemonic
LR
Function
Locked rotor
Type
Read only status flag
Description
Indicates the state of the rotor as locked (1) or unlocked (0).
Syntax
PR LR
Range
0/1
Usage
Program/Immediate, Read only
Code Example
PR LR
‘read rotor lead/lag
TA 2,k3 ‘trip to sub k3 on locked otor
Related
LT, TA
Mnemonic
LT
Function
Set locked rotor timeout
Type
Variable
Description
The LT variable will set the locked rotor timeout in
milliseconds. This setting will determine the time in
milliseconds that the output bridge will disable following the
locked rotor (LR) flag being active.
Syntax
LT=<time>
Units
Milliseconds
Range
2 — 65535
Default
2000 mS
LT (Locked rotor timeout)
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
5-44
Usage
Program/Immediate, Read/Write
Code Example
LT=1000
Notes
The output bridge will not disable if the Hybrid is in torque
mode (AS=3)
Related
AS, CB, LR
‘set locked rotor time to 1S
5 MCode Command Details
MCode Programming and Software Reference
MA (Move to an absolute position)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
MA
Function
Move to an absolute position
Type
Instruction
Description
Set mode for absolute move and move to an absolute
position relative to (0) zero. MD (Motion Mode) will be set to
MA. The time required to calculate the move is 2.5 mSec.
MA command will not operate during a homing sequence.
An in progress MA can be stopped with and "esc" entry or an
SL 0 command.
Syntax
MA <±position>,<parameter 2>, <parameter 3>
Parameter 2
0
(or blank) no action taken
1
Device name will be sent out of the serial port on move
completion.
0
(or blank) no action taken.
1
Motor will continue moving after reaching position.
Parameter 3
Usage
Program/Immediate
Code Example
MA 200000
MA 100000,1
Related
MD, MR, MS, P, SL
'Move to absolute position 200000
'Move to abs. pos. 100000, send DN when
'complete
MA 512000,0,1 'Move to abs. pos. 512000, continue
'motion after position is reached.
MD (Motion mode)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
MD
Function
Motion mode
Type
Variable
Description
Indicates what the last motion command was. When just a number
is entered, then it will execute the move type according to the
previous move type entered. This allows the user to apply numeric
data to the last motion command without having to enter the
command itself.
Syntax
PR MD
Units
Motor steps/Encoder counts
Usage
Program/Immediate. Read
Code Example
PR MD
MR 10000
5000
'Return the last motion command used to the
'terminal screen. Response will be the last
'motion command ie. MR
‘Move Relative 10000 steps
‘Motor will move relative 5000 steps
Notes
Note that if the IF flag is pending, numeric entry will be applied to
the IV (Input Variable).
Related
MA, MR, MS, P, PR, SL
5-45
MCode Programming and Software Reference
5 MCode Command Details
MF (Make up frequency)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
MF
Function
Set make up frequency
Type
Variable
Description
Defines the frequency at which missed steps are re-inserted
into the move profile.
Syntax
MF=<frequency>
Units
Hz
Range
306 — 5000000
Default
768000 Hz
Usage
Program/Immediate, Read/Write
Code Example
MF=256000
Notes
MF will be used for make up if MU=1
Related
MU, SS
Mnemonic
MP
Function
Moving to position
Type
Flag
Description
This flag will=1 when the axis is moving to a position
following a MA or MR instruction until MT expires..
Syntax
PR MP
Range
0/1
Status Response
0 Not moving
‘set make up freq to 25.6 kHz
MP (Moving to position)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Revision R062812
1 Moving to a position
5-46
Usage
Program/Immediate, Read
Code Example
PR MP
Related
MT
‘read the state of the MP flag to terminal
5 MCode Command Details
MCode Programming and Software Reference
MR (Move to a relative position)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
MR
Function
Move to a relative position
Type
Instruction
Description
Set mode for relative move and move a relative distance.
MD (Motion Mode) will be set to MR. The time required to
calculate the move is 2.5 mSec.
MR command will not operate during a homing sequence.
An in progress MR can be stopped with and "esc" entry or an
SL 0 command.
Syntax
MR <±position>,<parameter 2>, <parameter 3>
Parameter 2
0
(or blank) no action taken
1
Device name will be sent out of the serial port on move
completion.
0
(or blank) no action taken.
1
Motor will continue moving after reaching position.
Parameter 3
Usage
Program/Immediate
Code Example
MR 200000
MR 100000,1
Related
MD, MR, MS, P, SL
Revision R062812
'Move to relative position 200000
'Move to rel. pos. 100000, send DN when
'complete
MR 512000,0,1 'Move to rel. pos. 512000, continue
'motion after position is reached.
5-47
MCode Programming and Software Reference
5 MCode Command Details
MS (Microstep resolution select)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
MS
Function
Microstep resolution select
Type
Variable
Description
The MS variable controls the microstep resolution of the MCode
compatible device. There are 20 different microstep resolutions
that can be used with the device. The table below illustrates the
parameter settings and their associated resolutions for the 1.8°
stepping motor used with the MCode compatible device.
The MS parameters given in the table below are the only valid
parameters that will be accepted by the device.
Syntax
MS=<parameter>
Units
Microsteps per full motor step
Default
256
Parameters
Binary resolution parameters
per step
1
2
4
8*
16
32
64
128
256
per rev,
200
400
800
1600
3200
6400
12800
25600
51200
Decimal resolution parameters
per step
5*
10
25
50
100
125
200
250
per rev,
1000
2000
5000
10000
20000
25000
40000
50000
Additional resolution parameters
per step
108
127
180
per rev,
21600 (1 Arc Minute/μStep)
25400 (0.001mm/μStep)
36000 (0.01°/μStep)
Revision R062812
*Not recommended for MDrive Hybrid
5-48
Usage
Program/Immediate. Read/Write
Code Example
MS=5 'microstep resolution to 1000 steps/rev
Related
MA, MR, MS, P, PR, SL, C1
5 MCode Command Details
MCode Programming and Software Reference
MT (Motor settling delay time)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
MT
Function
Motor settling delay time
Type
Variable
Description
Specifies the motor settling delay time in milliseconds. MT allows
the motor to settle following a move. This is the time between
moves if consecutive motions are executed. the MV flag will be
active during this time.
Syntax
PR MT
Units
Milliseconds
Range
0 to 65000
Default
0
Usage
Program/Immediate. Read/Write
Code Example
MT=50
Notes
MT is added into HT (Hold Current Delay Time). The total of
the two cannot exceed 65535. Thus the maximum setting for
MT=(65535-HT).
‘Set motor settling delay time to 50 milliseconds
MT should be at least 50 mS when Encoder function is enabled
(EE=1)
HC, HT, RC
Revision R062812
Related
5-49
MCode Programming and Software Reference
5 MCode Command Details
MU (Make up mode)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Automatic position maintenance can be enabled which will insert steps as required,
when conditions allow, in the appropriate direction to bring the position difference between the commanded number of steps and actual steps taken to zero. The speed of
position maintenance can be performed at one (1) of two (2) speeds as specified by
the make up (MU) variable. Insertion can be at a specified speed or can be set at the
maximum speed the load will allow. There is no acceleration or deceleration applied
to position make up, therefore make up could be abrupt at high speed.
Mnemonic
MU
Function
Set make up mode
Type
Variable
Description
Determines the mode for position maintenance
Syntax
MU=<mode>,<parameter>
Range
0—2
Modes
0
Off
1
Use make up frequency (MF) as make up frequency
2
Use system speed (SS) as make up frequency
0
Use lead/lag (LL)
1
Clear lead/lag (LL)
Parameters
Default
0 (Off)
Usage
Program/Immediate, Read/Write
Code Example
MU=2,1
Notes
The make up parameter is not saved. Position maintenance
will only occur when motor lag/lead is within 1.1 motor
steps. Make up steps may be interleaved with motion steps
and made after a move has completed. Where position
maintenance occurs is dependant on motor lag/lead, motion
frequency and selected make up speed. Make up mode will
be cleared when bridges are disabled and Hybrid is enabled.
Related
MF, SS
Mnemonic
MV
Function
Axis in motion
Type
Flag
Description
Moving flag will be in a logic 1 state when a motion is
occurring. This flag will set an output ACTIVE if S<1-4,
9-12>=17
Syntax
PR MV
Range
0/1
Status Response
0 Not moving
‘use SS, clear LL
MV (Moving)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
1 Moving
5-50
Usage
Program/Immediate, Read
Code Example
PR MV
Related
VC, S1-S4, S9-S12
‘read the state of the MV flag to terminal
5 MCode Command Details
MCode Programming and Software Reference
NE (Numeric enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
NE
Function
Numeric enable flag
Type
Flag
Description
Numeric enable flag will enable (default) or disable the ability
of the device to execute the last motion command upon the
entry of a numeric value without the preceding command
being entered. By default, if a motion command is executed
i.e. MR 20000, when the user enters -20000, the device will
move relative -20000.
If disabled, the user must enter a motion command to
execute a move, i.e. MA 100000, MR -50000, SL 300000 etc.
Syntax
NE=<1/0>
Range
0/1
Default
1 (enabled)
Status Response
0 Disabled
1 Enabled (Default)
Usage
Program/Immediate, Read/Write
Code Example
NE=0
Related
MA, MR, SL
‘disable motion mode on numeric entry
O1, O2, O3 and O4 (Set outputs 1, 2 ,3 or 4)
Mnemonic
O1 - O4
Function
Set output logic state
Type
Variable
Description
This variable will set the logic state of the specified output to 1 or 0.
The voltage level will be dependant on the active (low/high) state of
the output, specified by the S<1-4> variable.
Syntax
Syntax:O<1-4>=<0/1>
Units
Logic 0 or 1
Range
0/1
Usage
Program/Immediate. Write
Code Example
O2=1
Related
O9-O12, OL, OH, OT, S1-S4
‘Set output 2 ACTIVE
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-51
MCode Programming and Software Reference
5 MCode Command Details
O9, O10, O11 and O12 (Set outputs 9, 10 ,11 or 12)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
O9 - O12
Function
Set output logic state
Type
Variable
Description
This variable will set the logic state of the specified output to 1 or 0.
The voltage level will be dependant on the active (low/high) state of
the output, specified by the S<1-4> variable.
Syntax
O<9-12>=<0/1>
Units
Logic 0 or 1
Range
0/1
Usage
Program/Immediate. Write
Code Example
O10=1
Related
O1-O4, OL, OH, OT, S1-S4
Mnemonic
OE
Function
On error handler
Type
Instruction
Description
When an error occurs, the specified subroutine is called. If a
program was running when the fault occurs, once the error routine
completes, program execution continues with the instruction after
the one that caused the error. After OE, the command is executed.
A program need not be running for the subroutine specified by OE
to run.
‘Set output 10 ACTIVE
OE (On error handler)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
The ON ERROR function is disabled by setting the address
parameter to 0 or resetting the device with an FD or CP OE
Subroutine MUST have an RT at the end.
OE will not execute during programming.
Revision R062812
Usage
5-52
Program
Code Example
OE K1
Related
EF, ER
‘run subroutine K1 on an error
5 MCode Command Details
MCode Programming and Software Reference
OL (Set outputs 1 - 4 as a group)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
OL
Function
Set the state of outputs 1 - 4 as one value
Type
Variable
Description
The OL variable allows the user to set Outputs 1-4 as one 4 bit
binary value. The value is entered in decimal, with a range of 0-15
in binary where Output 1 will be the LSb and Output 4 will be the
MSb.
Syntax
OL=<0-15>
Units
Decimal
Range
0 —15
Usage
Program/Immediate. Write
Code Example
OL=13
Related
IH, IN, IL, OH, OT, S1-S4
‘set output group 1-4 to 1101
OH (Set outputs 9 - 12 as a group)
Mnemonic
OH
Function
Set the state of outputs 9 - 12 as one value
Type
Variable
Description
The OH variable allows the user to set Outputs 9-12 as one 4 bit
binary value. The value is entered in decimal, with a range of 0-15
in binary where Output 9 will be the LSb and Output 12 will be the
MSb.
Syntax
OH=<0-15>
Units
Decimal
Range
0 —15
Usage
Program/Immediate. Write
Code Example
OH=13
Related
IH, IN, IL, OL, OT, S9-S12
‘set output group 9-12 to 1101
Revision R062812
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce (Plus2 expanded features)
5-53
MCode Programming and Software Reference
5 MCode Command Details
OT (Set outputs 1- 4 and 9 - 12 as a group)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
OT
Function
Set the state of outputs 1 - 4 and 9 - 12 as one value
Type
Variable
Description
The OT variable allows the user to set Outputs 1-4 and 9-12 as one
8 bit binary value. The value is entered in decimal, with a range of
0-255 in binary where Output 1 will be the LSb and Output 12 will
be the MSb.
Syntax
OH=<0-255>
Units
Decimal
Range
0 — 255
Usage
Program/Immediate. Write
Code Example
OT=214
Notes
NOTE: On Standard Plus Models OT will only set the lower group
(Outputs 1-4)
Related
IL, IH, IN, OL, OH, S1-S4, S9-S12
Mnemonic
P
Function
Position counter
Type
Variable
Description
This instruction is used to set or print the value of the MCode
compatible device position counter. The position will read in Motor
Steps from C1 (Counter 1) by default, if encoder functions are
enabled, the position counter will read in Encoder Counts from C2
(Counter 2).
‘set the standard output group to 11010110
P (Position counter)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Revision R062812
Modifying P in essence changes the frame of reference for the axis
for Move Absolute (MA) instructions. P will probably be set once
during system set up to reference or “home” the system.
5-54
Syntax
P=<±position>,
PR P
Units
Motor Steps (EE=0)/Encoder Counts (EE=1
Range
-2147483648 to +2147483647
Default
0
Usage
Program/Immediate. Read/Write
Code Example
PR P
Related
C1, C2
‘sprint the position to the terminal window
5 MCode Command Details
MCode Programming and Software Reference
PC (Position capture at trip)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce (Plus2 expanded features)
Mnemonic
PC
Function
Position capture at trip
Type
Instruction
Description
Captures motor or encoder position during a trip event. Activation
will occur upon any trip function EXCEPT a position trip (TP). Will
display in either motor steps (EE=0) or encoder counts (EE=1)
Syntax
PR PC
Usage
Immediate
Code Example
PR PC
Related
TE, TI, TC, TT, S13
Mnemonic
PG
Function
Enter/exit program mode
Type
Instruction
Description
This instruction toggles the device into or out of program mode.
Syntax
PG <address>
Usage
Immediate/Program
Code Example
PG 100 'enter program at address 100
...
...
'program body
...
PG
'end program return to immediate mode
Related
CP
‘Display captured position
PG (Program mode))
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-55
MCode Programming and Software Reference
5 MCode Command Details
PM (Position maintenance enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
PM
Function
Position maintenance enable
Type
Flag
Description
This flag will enable the position maintenance functions of
an MCode compatible device with encoder. The position
maintenance velocity will be at the setting for VI (Initial
Velocity). If moved beyond the value of DB (DeadBand), unit
will correct
If SM = 0 and PM = 1, Position Maintenance will take place
provided the position does not exceed the Stall Factor (SF).
If SM = 1 and PM = 1, Position Maintenance will take place
even if the Stall Factor (SF) is exceeded, unless VI is set too
high causing the motor to stall.
Syntax
PM=<1/0>
Range
0/1
Default
1 (enabled)
Status Response
0 Disabled (Default)
1 Enabled
Usage
Program/Immediate, Read/Write
Code Example
PM=1
Related
VI, EE, SM, DB, C2, SF
Mnemonic
PN
Function
Read device part number
Type
Variable
Syntax
PR PN
‘Enable position maintenance
PN (Part number)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-56
Usage
Immediate, Read
Code Example
PR PN
‘read the device part number
5 MCode Command Details
MCode Programming and Software Reference
PR (Print specified data or text)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
PR
Function
Print specified data or text
Type
Instruction
Description
This instruction is used to output text and parameter value(s) to
the host PC. Text should be enclosed in quotation marks while
parameters (variables and flags) should not. Text strings and
parameters which are to be output by the same PR instruction
should be separated by commas. The information being output
is followed by a carriage return unless a semicolon (;) is included
at the end of the PR instruction to indicate that the cursor should
remain on the same line.
It is important to note that the receive buffer for the MCode device
is 64 characters, this includes the PR instruction itself, any spaces,
text characters, etc. If the buffer length is exceeded a CR/LF will
ocur and set error 20.
Syntax
PR <text>, <data>
Usage
Immediate
Code Example
PR “Position =”, P
PR MS
Notes
A delay time between the print requests to the device must be
considered to allow the device time to interpret a command and
answer the host before a subsequent command can be sent.
Mnemonic
PS
Function
Pause program execution
Type
Instruction
Description
This instruction is used to pause an executing program and
invoke normal deceleration of any motion being executed to Zero.
Immediate mode instructions are allowed while a program is in a
paused state. To resume the program the RS instruction is used.
Syntax
PS
Usage
Immediate
Code Example
PS
Related
RS, SL, MA, MR, HI, HM
‘print axis position
‘Print the μStep Resolution setting
PS (Pause program execution)
‘Pause running program
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-57
MCode Programming and Software Reference
5 MCode Command Details
PW (PWM configuration)
Compatible with Motion Control products:
MForce
MForce (Plus2 expanded features)
!
CAUTION
This variable is only applicable to the MForce Product Line and is used to tune the
PWM Settings to optimize the current control of the MForce Driver. It should not be
used unless erratic motion or positional accuracy problems are being experienced.
Note that there are other factors that could contribute to these problems. Ensure
that all wiring conforms to the guidelines in the MForce Hardware Manual.
Be aware that this parameter, when used with the checksum will write to the
boot sector of memory. This sector only allows eight write cycles. Ensure that the
settings you choose are optimal prior to storing the parameter to the boot.
Read this section closely before making changes to the PWM settings. Please
contact application support for questions concerning the use of this command.
Mnemonic
PW
Function
PWM configuration
Type
Variable
Description
The PW variable is only used on the MForce product line. It is not
a reserved word on the MDrive product line and may be used as a
User Variable or Label.
This variable is used to set the PWM Current Control settings of
the MForce ONLY! It does not apply in any function to the MDrive
series and may be used as a label or user variable or flag.
See Appendix G of this document for parameter settings and
usage. It is recommended that these settings not be modified from
the factory default unless the motor exhibits rough motion, audible
noise or poor zero-crossing performance. If these symptoms exist,
please check for other issues such as electrical noise coupled onto
logic signals or ground loops before modifying these settings.
Syntax
PW=<mask>,<period>,<sfreq>, <chksum>
Revision R062812
PR PW (Response = <mask>,<period>,<sfreq>,<boot_writes_
remaining>
5-58
Units
Vary
Range
See tables in Section 7.4: MForce PWM Settings, of this document.
Default
204,95,170
Usage
Immediate. Read/Write
5 MCode Command Details
MCode Programming and Software Reference
PY (Party mode enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
PY
Function
Party mode enable
Type
Flag
Description
The party flag must be set to 1 if the device is being used in
a multidrop communication system.
When Party Mode is enabled, each device in the system
must be addressed by the host computer by using the device
name specified by the DN instruction. This name will precede
any command given to a specified unit in the system and
be terminated with a Control J (CTRL + J). One CTRL + J
must be issued after power up or entering the Party Mode to
activate the Party Mode. By default the DN assigned at the
factory is the exclamation character (!) .
The global Drive Name is the asterisk character (*).
Commands preceded by this character will be recognized by
every MCode compatible device in the system.
After the Party Mode is enabled, send CTRL + J (^J) to
activate it. Type commands with Device Name (DN) and use
CTRL + J as the Terminator.
Syntax
PY=<0/1>
Range
0/1
Default
0 (disabled)
Status
0 Disabled (Default)
1 Enabled
Usage
Program/Immediate, Read/Write
Code Example
PY=1
Notes
Note: A delay time between the command requests to
the device must be considered to allow the device time
to interpret a command and answer the host before a
subsequent command can be sent. The time between
requests is dependent on the command and the
corresponding response from the Device.
Related
DN, DG
Revision R062812
‘Enable Party Mode Communications
5-59
MCode Programming and Software Reference
5 MCode Command Details
QD (Queued)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
QD
Function
Queued
Type
Flag
Description
Function is to queue drives on party lines. Works similar to
uLynx QUED flag.
If a drive or drives are Queued, then, when they see the
address “^”, they will respond to it. All other, non-queued
drives will ignore the command
Syntax
QD=<0/1>
Range
0/1
Default
0 (disabled)
Status
0 Disabled (Default)
1 Enabled
Usage
Immediate, Read/Write
Code Example
QD=1
Related
PY, DN
‘Queue Drive
R1, R2, R3 and R4 (User registers)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-60
Mnemonic
R1 - R4
Function
User registers
Type
Variable
Description
The MCode compatible device has four 32 bit user registers
to contain numerical data. These registers may contain up
to 11 digits including the sign and may be used to store and
retrieve data to set variables, perform math functions, store
and retrieve moves and set conditions for branches and call
subroutine.
Syntax
R<1-4>=<number>
Range
-2147483647 to 2147483647
Usage
Immediate, Read/Write
Code Example
R1=50000
‘Set Register 1 to 50000
R2=Q2 ‘Set Reg. 2 to the value of User Variable Q2
5 MCode Command Details
MCode Programming and Software Reference
RC (Motor run current)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
RC
Function
Motor run current
Type
Variable
Description
This variable defines the motor run current in percent.
HC=(%)
MDrive
MDrive
Hybrid
MForce
MicroDrive
(A RMS)
MForce
PowerDrive
(A RMS)
(All)
10
0.3
0.5
0.6
1.0
0.9
1.5
1.2
2.0
1.5
2.5
1.8*
3.0
2.1*
3.5
2.4*
4.0
90
2.7*
4.5
100
3.0*
5.0
20
MDrive Range
0 To 100%
30
40
50
60
70
80
Actual Current
Not required
as Motor is
appropriately
sized to the
device.
*Older versions of the MForce MicroDrive would output 2.0 A
RMS. For these drives 67% run current will output 2.0 A. The
3.0 A MicroDrives are marked 3.0 Amps on the label.
Syntax
RC= <percent>
Units
Percent
Range
1 to 100
Default
25%
Usage
Program/Immediate
Code Example
RC=50
Related
HC
'set run current to 50%
RS (Resume program execution)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
Mnemonic
RS
Function
Resume program execution
Type
Instruction
Description
This instruction is used to resume a program that has been paused
using the PS instruction. Any move that was paused will resume as
well. Motion will resume using the normal acceleration profiles.
Syntax
RS
Usage
Immediate
Code Example
RS
Related
PS, SL, MA, MR, HI, HM
‘Resume paused program
5-61
MCode Programming and Software Reference
5 MCode Command Details
RT (Return from subroutine)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
RT
Function
Return from called or on-error subroutine
Type
Instruction
Description
This instruction defines the end of a subroutine. This instruction
is required and will be the final instruction in the subroutine
executed by the CL or OE instruction. When used, it will return to
the program address immediately following the instruction which
executed the subroutine.
Syntax
RT
Usage
Program
Code Example
CL K8 ‘Call Subroutine K8
LB K8
*****SUBROUTINE K8*****
RT
‘Go back to main program
Related
CL, OE
Mnemonic
S
Function
Save to NVM
Type
Instruction
Description
Saves all variables and flags currently in working memory (RAM)
to nonvolatile memory (NVM). The previous values in NVM are
completely overwritten with the new values.
S (Save to NVM)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
When the user modifies variables and flags, they are changed in
working memory (RAM) only. If the S instruction is not executed
before power is removed from the control module, all modifications
to variables & flags since the last S will be lost.
Syntax
S
Usage
Program/Immediate
Code Example
S
Notes
Note: Communications during a Save could corrupt
communications. If a Save is performed during the execution of a
motion command, trips may be delayed.
‘Save all variable and flag states to NVM
Revision R062812
Use of the S command during a move (MA or MR) will generate an
error 73, the save will not occur.
5-62
5 MCode Command Details
MCode Programming and Software Reference
S1, S2, S3, S4, S9, S10, S11, S12 (Setup I/O points 1 - 4 & 9 - 12)
Compatible with Motion Control products:
S1 - S4
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
S1 - S4, S9 - S12
Function
Set up I/O point
Type
Instruction
Description
This instruction is used to setup the I/O type and active
states, and sink/source setting. Each of the device I/O points
may be programmed as either general purpose inputs and
outputs, or to dedicated input function or dedicated output
function.
S9 - S12
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MForce (Plus2 expanded features)
When programmed as inputs, these points can be sinking or
sourcing, and may be programmed such that they are active
when pulled to ground, or active when left floating. By default
each point is configured as a general purpose input, active
when LOW.
When configured as outputs on devices with Plus2 expanded
features the outputs may be sinking or sourcing. For
standard MDrive and MForce devices the outputs are sinking
only.
Revision R062812
There are three parameters attached to this instruction:
1.
The type specifies the function of the I/O point (see
tables - following page).
2.
The second parameter sets the active state, which
defines the point as (0 - Default) LOW or (1) HIGH
ACTIVE.
3.
The third parameter specifies whether the point will be
(0 - Default) sinking or sourcing (1).
Syntax
S<point number>=<type>,<0/1>,<0/1>
Input Types
0
General purpose input
1
Homing function, will function as specified by the
homing command (HM).
2
Limit +, will function as specified by the limit
command (LM).
3
Limit —, will function as specified by the limit
command (LM).
4
G0 input, will run program at address 1 upon
activation.
5
Soft stop, stops motion with deceleration and halts
program execution. If program is paused (PS), input
is ignored.
6
Pause, pause/resume program with motion
7
Jog +, Will Jog motor in the positive direction at Max.
Velocity (VM). The Jog Enable (JE) Flag must be set
for this to function.
8
Jog —, Will Jog motor in thenegative direction at
max. velocity (VM). The jog enable (JE) flag must be
set for this to function.
11
Reset, When set as RESET input, then the action is
equivalent to a ^C entered into a terminal. Note: If
setting the input to sourcing, active true, ground the
input first or a reset will occur.
5-63
MCode Programming and Software Reference
5 MCode Command Details
Output Types
Parameter 2
Parameter 3
Default
16
General purpose
17
Moving, output will be active while the moptor is in
motion.
18
Fault, will be active when an error occurs.
19
Stall, will be in the Active State when a stall is
detected. Encoder Required, Stall Detect Mode (SM)
must be enabled.
20
Velocity changing, will be in the Active State when the
velocity is changing.
21
Locked rotor (MDrive Hybrid ONLY).
23
Moving to position, will be in an active state while
moving to an absolute position.
24
Hybrid active (MDrive Hybrid ONLY).
25
Make up active (MDrive Hybrid ONLY).
0
Active when LOW (default)
1
Active when HIGH
0
Sinking (default)
1
Sourcing
0 (Off)
Usage
Program/Immediate, Read/Write
Code Example
S1=1,0,0
‘IO1 to homing input, active LOW, sinking
S2=4,1,1
‘IO2 = G0 input active HIGH, sourcing
S3=17,1,0 ‘IO3 = moving output, active HIGH, sinking
Notes
1.
Output Types are SINKING ONLY on Plus devices.
2.
Once set wait debounce time before using an input.
Related
I1-4, I9-12, IN, O1-4, O9-12, OT, D1-D4
Output Circuit Conditions
S1=16,1,0
O1 = 1 (Sink OFF, High Impedance)
Output, Active High, Sinking
O1 = 0 (Sink ON)
S1=16,0,0
O1 = 1 (Sink ON)
Output, Active Low, Sinking
O1 = 0 (Sink OFF, High Impedance)
S1=16,1,1 (Plus Only)
O1 = 1 (Source ON)
Output, Active High, Sourcing
O1 = 0 (Source OFF, High Impedance)
S1=16,0,1 (Plus Only)
O1 = 1 (Source Source OFF, High Impedance)
Output, Active Low, Sourcing
O1 = 0 (Source ON)
2
Revision R062812
2
5-64
5 MCode Command Details
MCode Programming and Software Reference
S5 (Set analog input)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
S5
Function
Set analog input
Type
Instruction
Description
This I/O point configures the analog input as either a current
or voltage input. The value of this input will be read using the
I5 instruction, which has a range of 0 to 1023.
The first parameter sets the input type as either voltage or
current.
The second parameter specifies the voltage/current range:
Note that for 4 to 20 mA current mode, the range for I5 is 205
to 1023.
1st Parameter
9
Sets the analog input as a voltage input (default).
10 Sets the analog input to a current input.
2nd Parameter
0
Sets the input range to 0 to 5 V, or 4 to 20 mA (default).
1
Sets the input range to 0 to 10 V, or 0 to 20 mA.
Syntax
S5= <type>, <0/1>
Default
Voltage reference, 0 to +5 VDC
Usage
Program/Immediate, Read/Write
Code Example
S5=9,0
S5=9,1
S5=10,0
S5=10,1
Related
I5, JE
Input
Input
Input
Input
=
=
=
=
voltage,
voltage,
current,
current,
0-5 VDC
0-10 VDC
0-20 mA
4-20 mA
Revision R062812
‘Analog
‘Analog
‘Analog
‘Analog
5-65
MCode Programming and Software Reference
5 MCode Command Details
S7 & S8 (Setup clock I/O points)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MForce (Plus2 expanded features)
Mnemonic
S7 - S8
Function
Set up clock I/O point
Type
Instruction
Description
Sets up I/O 7 and I/O 8 clock type. Can be set as inputs or
outputs, I/O 7 and I/O 8 are setup in pairs. The clock types
are step clock/direction, up/down, and quadrature.
Syntax
S<7/8>=<type>,<active>
Input Types
33
Step/Direction , sets I/O 7 and 8 to receive step and
direction inputs from an external source. The motion
will occur based on the input frequency seen at I/O 7
in the Direction relative to the logic state of I/O 8. The
step rate will be based upon the ratio set by Clock
Ratio (CR)
34
Quadrature, sets I/O 7 and 8 to receive Channel A
and Channel B Quadrature inputs from an external
source such as an encoder. The motion will follow the
Quadrature Input. The clock rate will be based upon
the ratio set by Clock Ratio (CR)
35
Up/Down, sets I/O 7 and 8 to receive Clock Up/Clock
Down inputs from an external source. The motion will
occur based upon the input clock frequency in the
direction relative to the input being clocked. The step
rate will be based upon the ratio set by Clock Ratio
(CR)
49
Step clock pulses will be output from Point 7,
Direction from Point 8. The step clock output rate will
be based upon the Pulse Width set by Clock Width
(CW). The logic state of the Direction output will be
with respect to the direction of the motor.
50
Will output Quadrature signals.
51
Will output Clock Up/Clock Down signals. The step
clock output rate will be based upon the Pulse Width
set by Clock Width (CW). The Active output will be
based on the motor direction.
0
Active when LOW (default)
1
Active when HIGH
Output Types
Parameter 2
Usage
Program/Immediate, Read/Write
Code Example
S7=33,0
S8=33,0
'IO7 = step/direction input, active LOW
'IO8 = step/direction input, active LOW
S7=50,1
S8=50,1
‘IO7 = quadrature output, active HIGH
‘IO8 = quadrature output, active HIGH
Revision R062812
Related
5-66
FM, CW, CM
5 MCode Command Details
MCode Programming and Software Reference
S13 (Setup capture input/trip output)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
S13
Function
Set up capture/trip I/O point
Type
Instruction
Description
Sets up high speed position capture input and position trip
output.
Syntax
S13=<type>,<active>
Input Type
60
The Capture input is a momentary high speed input
that operates with the Trip Capture (TC) variable to
run a subroutine upon the trip. It feature variable input
filtering ranging from 50 nS to 12.9 μS
61
The trip output will activate on Position Trips (TP) or
Trip Relative (TR). The output will pulse out at the trip
point. The pulse width will be determined by Clock
Width (CW)
0
Active when LOW (default)
1
Active when HIGH
Output Type
Parameter 2
Usage
Program/Immediate, Read/Write
Code Example
S13=60,0
Notes
Note that this I/O Point is for position capture and trip ONLY.
It is not effected by any other trips.
Related
FC, CW, TP, TR, PC
Mnemonic
SC
Function
Start calibration
Type
Instruction
Description
Starts calibration
Syntax
SC
Units
—
Usage
Program/Immediate, Write
Code Example
SC
Notes
Start calibration mode 0 will initiate a Hard Stop Calibration
resulting in a small motion of 10.8° CCW followed by 5.4°
CCW to align the rotor to the stator.
Related
CA, CC, CT, CF
'Set up IO13 as High Speed Capture
'Input, active LOW (default)
SC (Start calibration)
‘start calibration
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
5-67
MCode Programming and Software Reference
5 MCode Command Details
SF (Stall factor)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
SF
Function
Stall factor
Type
Variable
Description
If the encoder is enabled (EE = 1) and the encoder differs
from the commanded position by more than the specified
factor, a STALL is indicated. If SM is set to 0, then the motor
will be stopped when a STALL is detected. If SM=1, the
motor will not be stopped upon detection of a stall. ST will
return an ER=86 on stall.
Syntax
SF=<counts>
Units
Encoder counts
Range
0 to 65000
Default
15
Usage
Program/Immediate, Read/Write
Code Example
SF=20
Related
EE, SM, ST, PM
Mnemonic
SL
Function
Slew Axis
Type
Instruction
Description
The SL instruction will slew the axis at the specified velocity
in steps per second. The axis will accelerate at the rate
specified by the A (Acceleration) variable.
‘Set the stall factor for 20 counts
SL (Slew axis)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Revision R062812
Note that the maximum slew velocity is independent of the
maximum velocity specified by the VM variable. If a slew
is commanded at a velocity greater than the setting of VM,
the axis will accelerate to the SL velocity regardless of the
setting of VM.
5-68
Syntax
SL <velocity>
Units
Motor Steps (EE=0)/Encoder Counts (EE=1)
Range
±5000000 (EE=0)/±200000 (EE=1)
Usage
Program/Immediate, Read/Write
Code Example
SL 20000
Notes
If ‘SL 0’ is issued after a MA/MR, motion has to come to a
stop before issuing another motion command. This can be
accomplished automatically with an ‘H’, <HOLD>, in user
program mode.
Related
MA, MR, VI
‘Slew at a rate of 20000 steps/sec
5 MCode Command Details
MCode Programming and Software Reference
SM (Stall detect mode)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MForce
MForce (Plus2 expanded features)
Mnemonic
SM
Function
Stall detection mode
Type
Variable
Description
The SM variable specifies the action which will be taken by
the device when a stall is detected. When set to 0 (default)
the motion will be stopped upon a stall detection. When
SM=1, the motor will try to continue the move. In either case
ST (Stall Flag) will be set.
The functionality of SM when used with Position Maintenance
(PM) is listed below:
If SM = 0 and PM = 1, Position Maintenance will take place
provided the position does not exceed the Stall Factor (SF).
If SM = 1 and PM = 1, Position Maintenance will take place
even if the Stall Factor (SF) is exceeded, unless VI is set too
high causing the motor to stall.
Syntax
SM <mode>
Modes
0
Motion stops on stall detect (default)
1
Motion will attempt to continue
Default
0
Usage
Program/Immediate, Read/Write
Code Example
SM=1
Related
EE, SM, ST, PM, SF
Mnemonic
SN
Function
Serial number
Type
Variable
Description
Keyword allows the user to read the device serial number.
Syntax
PR SN
Usage
Read
Code Example
PR SN
'Change Stall mode that the motor doesn’t
'stop on stall detect
SN (Serial number)
‘read the device serial number
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
5-69
MCode Programming and Software Reference
5 MCode Command Details
SS (System speed)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
SS
Function
Set system speed
Type
Instruction
Description
Sets maximum response frequency for fixed or variable
current modes (AS=1 or 2)
Syntax
SS=<integer>
Units
steps/sec
Range
38,910 — 5,000,000
Default
0
Usage
Program/Immediate, Read/Write
Code Example
SS=50000
Related
AS, TS, MU
Mnemonic
ST
Function
Stall flag
Type
Flag
Description
The ST flag will be set to 1 when a stall is detected. It is
the responsibility of the user to reset it to zero (0). Encoder
function must be enabled (EE=1) in order for a stall flag to set.
Syntax
PR ST
BR <addr>, ST=1
CL <addr>, ST=1
Status
0
Not stalled (default)
1
Stalled
‘set max. osc freq to 50000
'steps/sec
ST (Stall flag)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MForce
MForce (Plus2 expanded features)
Revision R062812
Default
5-70
0
Usage
Program/Immediate, Read/Write
Code Example
CL K5,ST=1
ST=0
Related
EE, SF, OE
‘Call subroutine K5 if motor stalls
‘Clear stall flag
5 MCode Command Details
MCode Programming and Software Reference
SU (Execute program on power up)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
SU
Function
Execute program labeled SU on power up
Type
Predefined label
Description
The Start up label will cause any program labeled SU to
automatically execute on power-up.
Syntax
LB SU
Usage
Program
Code Example
LB SU
Mnemonic
TA
Function
Trip on hybrid status
Type
Variable
Description
Will execute a subroutine address or label on the trip. The
trip can be set to occure on any or all of three conditions:
calibration done, hybrid active, locked rotor or lead/lag limit
reached conditions.
Syntax
TA <flag>,<address/label>
Units
—
Range
0 —7
Trip Condition
1
Calibration done
2
Hybrid active
4
Locked rotor
‘Label program to executes on power up.
TA (Trip on Hybrid status)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Default
8
Lag limit reached
16
Lead limit reached
0 (Off)
Usage
Program/Immediate, Read/Write
Code Example
TA=4,k6 ‘execute subroutine k6 on locked
rotor condition
Notes
The conditions are additive, eg. TA=3 will trip on calibration
complete and hybrid active status.
Revision R062812
There is no error generation when enabling trip on locked
rotor, lag limit or lead limit.
5-71
MCode Programming and Software Reference
5 MCode Command Details
TC (Trip capture)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce (Plus2 expanded features)
Mnemonic
TC
Function
Trip capture
Type
Variable
Description
Sets the Capture input trip for I/O 13. Sets one parameter for
trip address. The TE command (Trip Enable/Disable TC) is
reset when trip occurs. TE must be re-enabled in the main
program prior to the next trip if it is to be repeated. The Trip
subroutine must use a RETURN (RET) to exit the subroutine,
use of a BRANCH will cause stack errors.
Syntax
TC=<address/label>
Usage
Program/Immediate, Read/Write
Code Example
TC=K1
TE=4
Related
TE, S13
Mnemonic
TD
Function
Set torque direction
Type
Variable
Description
Sets torque direction to + or –
Syntax
TD=<dir>
Units
—
Range
0—1
Modes
0
Minus (CCW facing shaft)
1
Plus (CW facing shaft)
‘Run subroutine K1 on Input Trip
‘Re-enable Trip
TD (Torque direction)
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
5-72
Default
1
Usage
Program/Immediate,Read/Write
Code Example
TD=0
Notes
Takes effect when torque mode starts
Related
AS, TQ, TS
‘set torque direction to minus
5 MCode Command Details
MCode Programming and Software Reference
TE (Trip enable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
TE
Function
Trip enable
Type
Flag
Description
The trip functions may be combined by adding trip numbers.
For example TE=3 will trip on input or on position, TE=63
enables all trips. When multiple trips are used only the
activated trip function needs to be re-enabled, the other trips
will still be enabled.
Syntax
TE=<trip>
Range
0 — 63
Trip
0
Disabled (default)
1
Trip on input enabled
2
Trip on position enabled
4
Trip on capture (I/O 13) enabled
8
Trip on time enabled
16
Trip on relative position
32
Trip on Hybrid status
Default
0 (Off)
Usage
Program/Immediate, Read/Write
Code Example
TE=1
TE=8
TE=6
Related
I1-I4, I9-I12, P, S1-S4, S9-S12, TI, TP, TC, TT
Mnemonic
TI
Function
Trip on input
Type
Variable
Description
Sets up an input event (Trip) for the specified input. There
are two parameters for the TI variable. The first specifies
which input line to monitor. The second specifies the
subroutine that should be executed when the input goes to
true. The Trip subroutine must use a RETURN (RET) to exit
the subroutine, use of a BRANCH will cause stack errors
‘Enable trip on input function
‘Enable trip on time function
‘Trip on Position or Capture input.
TI (Trip on input)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
The TE is reset when a Trip occurs. TE must be re-enabled
prior to the next Trip if it is to be repeated.
Revision R062812
Syntax
TI=<input>,<address/label>
Usage
Program/Immediate, Read/Write
Code Example
TI=2,K3
TE=1
Related
‘execute subroutine K3 when input 2 active
‘Re-enable Trip
I1-4, S1-4, TE, TP, TT
5-73
MCode Programming and Software Reference
5 MCode Command Details
TP (Trip on position)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
TP
Function
Trip on position
Type
Variable
Description
Sets up an event (trip) for the specified position. There are
two parameters for the TP variable. The first specifies the
position which will cause the event. The second specifies
the subroutine that should be executed when the position is
detected.
The TE (Trip Enable which Enables/Disables TP) is reset
when a Trip occurs. TE must be re-enabled in the main
program prior to the next Trip if it is to be repeated. The Trip
subroutine must use a RETURN (RET) to exit the subroutine,
use of a BRANCH will cause stack errors.
Trips should be set BEFORE motion commands in the
program.
Syntax
TP=<position>,<address/label>
Usage
Program/Immediate, Read/Write
Code Example
TP=650000,K9
TE=2
Notes
Note that TP will always use motor counts regardless of the
encoder enabled state (EE=1)
Related
P, TI, PC, S13, CW
Mnemonic
TQ
Function
Set torque
‘exe sub K9 when position = 650000
‘Re-enable trip
TQ (Set torque)
Revision R062812
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
5-74
Type
Variable
Description
Sets the maximum out put torque of the motor to a
percentage.
Syntax
TQ=<percent>
Units
Percent
Range
1 — 100
Default
25%
Usage
Program/Immediate, Read/Write
Code Example
TQ=50
Related
AS, CT
‘set torque to 50%
5 MCode Command Details
MCode Programming and Software Reference
TR (Trip on relative position)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce (Plus2 expanded features)
Mnemonic
TR
Function
Trip on relative position
Type
Variable
Description
Sets up an event (trip) for the specified relative position.
There are three parameters for the TR variable.
The first specifies the position which will cause the event.
The second specifies the subroutine that should be executed
when the position is detected, if no subroutine address
or label is specified then the High Speed Trip Output will
activate. The Trip subroutine must use a RETURN (RET) to
exit the subroutine, use of a BRANCH will cause stack errors
The third parameter specifies the number of times the trip will
repeat. If 0 (default) the trip will repeat infinite times, other
wise the range is 1- 65000
The TE (Trip Enable which Enables/Disables TR) is reset
after repeating the number of relative trips specified. TE
must be re-enabled in the main program prior to the next
series of Trip on Relative if it is to be repeated. For exampl,
if TR=10000,0,25, the Output (S13) will trip 25 times in
succession at 100,000 counts relative to the last position.
Following these 25 trips the trip must be re-enabled (TE=16).
Trips should be set BEFORE motion commands in the
program.
Syntax
TR=<±dist>,<address/label>, <repeat>
Usage
Program/Immediate, Read/Write
Code Example
TR=650000,0,0
TE=16
‘Activate trip out when at 650000
‘counts relative
‘Re-enable trip
TR=512000,K2,27
TE=16
Notes
‘Run Sub K2 when at 512000 rel,
‘repeat 27 times
‘Re-enable trip
Note: Output S13 must be configured as a trip output
(S13=61,1/0)
Note that TR will always use motor counts unless the
encoder is enabled (EE=1).
Note: The maximum rate of trip is 20 kHz. Exceeding this
may cause communications errors
P, TI, PC, S13, CW
Revision R062812
Related
5-75
MCode Programming and Software Reference
5 MCode Command Details
TS (Set torque speed)
Compatible with Motion Control products:
MDrive Hybrid
MDrive Hybrid (Ethernet)
Mnemonic
TS
Function
Set torque speed
Type
Instruction
Description
Determines the system speed for torque mode (AS=3)
Hybrid will perform the following calculation based upon the
value of TS:
Syntax
TS=<integer>
Units
steps/second
Range
38,910 — 5,000,000
Default
0
Usage
Program/Immediate, Read/Write
Code Example
TS=50000
Related
AS, SS, MSEL
Mnemonic
TT
Function
Trip on time
Type
Variable
Description
Sets up a trip based on time. The first parameter is time
in mSec. The second parameter specifies the subroutine
that should be executed when the time is expired. The Trip
subroutine must use a RETURN (RET) to exit the subroutine,
use of a BRANCH will cause stack errors
Syntax
TT=<time>,<address/label>
Umits
Milliseconds
Range
1 to 65535
‘set spd to 50000 steps/sec
TT (Trip on position)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-76
Usage
Program/Immediate, Read/Write
Code Example
TT=2000,K3
TE=8
Related
TE, TP, T
‘Trip on time 2000 mS, run- sub K3
‘Re-enable trip
5 MCode Command Details
MCode Programming and Software Reference
UG (Upgrade firmware)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
UG
Function
Upgrade firmware
Type
Instruction
Description
Upgrade Firmware Instruction. Upgrade code is 2956102.
This will put the device in Upgrade Mode. Once set, the
firmware Upgrade MUST be completed.
Usage
Immediate
Mnemonic
UV
Function
Read user variables
Type
Variable
Description
Read User Variables is used with the PR (Print) Instruction to
read the value of all user variables.
Syntax
PR UV
Usage
Program/Immediate, Read
Code Example
PR UV
UV (Read user variables)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
‘Read the value of all user variables
Related
PR, VA
Mnemonic
V
Function
Read axis velocity
Type
Variable
Description
The velocity variable is used in conjunction with the PR
(print) instruction to read the current velocity of the axis in
counts per second. This variable can also be used with the
BR and CL instructions to set a condition based upon a
velocity.
Syntax
PR V
BR <address/label>, V=<velocity>
BR <address/label>, V=<velocity>
Usage
Program/Immediate, Read
Code Example
PR V
CL Ka, V=20000
Notes
Note that V is signed. When using an Hybrid product V will
not return an accurate value when Hybrid make up is active.
In torque mode V will return 0.
Related
VI, VM, SL, MA, MR
V (Read velocity)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
‘Read the velocity
‘Execute sub Ka when velocity is
‘20000/steps sec in the + direction
CL Kb, V=-20000 ‘Execute sub Kb when velocity is
‘-20000/steps sec in the - irection
5-77
MCode Programming and Software Reference
5 MCode Command Details
VA (Create user variable)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
VA
Function
Create user variable name
Type
Instruction
Description
The VA instruction creates a user variable with a 1 or 2
character name. Can optionally set value assigned to that
variable.
The restrictions for this command are:
Syntax
1.
A variable cannot be named after a MCode Instruction,
Variable or Flag or Keyword
2.
The first character must be alpha, the second character
may be alpha-numeric.
3.
A variable is limited to two characters.
4.
Limited to 192 variables and labels.
VA <char><char>=<value>
Usage
Program/Immediate, Read/Write
Code Example
VA Q3
VA Q3=20000
Related
UV
Mnemonic
VC
Function
Velocity changing
Type
Flag
Description
The read-only motion flag will be at an active state (1) when
the velocity of the motor is changing, either accelerating or
decelerating.
Syntax
PR VC
BR <addr>, VC=1
CL <addr>, VC=1
Range
0/1
Trip
0
Motor stopped or at constant velocity (default)
1
Velocity is changing
‘Create user Variable Q3
‘Create user Variable Q3, set to 20000
VC (Velocity changing)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Revision R062812
Default
5-78
0 (not active)
Usage
Program/Immediate, Read/Write
Code Example
CL K5,VC=1
PR VC
Related
MV, VI, VM, S1-S4, S9-S12
‘Call sub K5 if velocity is changing
‘Print the state of the VC Flag
5 MCode Command Details
MCode Programming and Software Reference
VF (Torque velocity filter)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
VF
Function
Set torque velocity filter
Type
Variable
Description
VF takes a value of 0 to 1000. It can be defined as 0 = no
filtering and 1000 = most filtering.
Because the Torque Velocity is computed and the encoder
is sampled every mSec there can be fluctuation in the result.
The filtering compensates for this fluctuation.
Syntax
VF=<integer>
Units
Counts
Range
0 to 1000
Default
0
Usage
Program/Immediate, Read/Write
Code Example
VF=100
Mnemonic
VI
Function
Initial velocity
Type
Variable
Description
Initial velocity for all motion commands. The factory default
value is 1000 clock pulses (steps) per second.
‘Set filtering to 100 counts
VI (Initial velocity)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
The initial velocity for a stepper should be set to avoid the
low speed resonance frequency and must be set lower than
the pull in torque of the motor. It must also be set to a value
lower than VM (Max. Velocity).
Syntax
VI=<velocity>
Units
Motor Steps (EE=0)/Encoder Counts (EE=1)
Range
1 to (VM –1)
Default
1000/40
Usage
Program/Immediate, Read/Write
Code Example
VI=10000
Related
VM, MR, MA, HI, HM, JE
Revision R062812
‘Set initial vel to 10000 steps/sec.
5-79
MCode Programming and Software Reference
5 MCode Command Details
VM (Maximum velocity)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
Mnemonic
VM
Function
Maximum velocity
Type
Variable
Description
The VM variable specifies the maximum velocity in steps/
counts per second that the axis will reach during a move
command.
VM must be greater than VI.
Syntax
VM=<velocity>
Units
Motor Steps (EE=0)/Encoder Counts (EE=1)
Range
(VI + 1) to 5000000 (EE=0)/200000 (EE=1)
Default
768000/30720
Usage
Program/Immediate, Read/Write
Code Example
VM=500000
Related
VI, MR, MA, HI, HM, JE
Mnemonic
VR
Function
Firmware version
Type
Variable
Description
This variable is used in conjunction with the PR instruction to
read the version of the firmware installed at the factory.
Syntax
PR VR
Usage
Read
Code Example
PR VR
Notes
Hybrid products will return a second value for the
hardware version.
Related
UG
‘Set max vel to 500000 steps/counts sec.
VR (Firmware version)
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-80
‘Read the firmware version installed
5 MCode Command Details
MCode Programming and Software Reference
WT (Warning temperature)
Mnemonic
WT
Function
Warning temperature
Type
Variable
Description
The Warning Temperature variable allows the user to set a
threshold temperature at which the device will print an error
71 to the terminal screen if the set temperature is exceeded.
Syntax
WT=<temp>
Units
Degrees C
Range
0 to 84
Default
80
Usage
Program/Immediate, Read/Write
Code Example
WT=75
Notes
NOTE: This functionality is only standard on MDrive 34 (DC
and AC), MForce PowerDrive and all Hybrid devices.
Related
IT
‘set the warning temperature to 75 deg. C
Revision R062812
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive (Ethernet)
MDrive Hybrid
MDrive Hybrid (Ethernet)
MForce
MForce (Plus2 expanded features)
5-81
Revision R062812
5 MCode Command Details
5-82
MCode Programming and Software Reference
MCode Programming and Software Reference
6
6 Supporting Software
Supporting Software
There are two programs provided for configuring, controlling and programming the Motion Control products. These are:
6.1
1.
IMS Terminal: integrated ASCII program editor/ANSI terminal
emulator used to program and immediate mode control the Motion
Control products.
2.
TCP/IP Configuration Utility: configuration tool used to setup and
test the Ethernet MDrive Motion Control products. When using the
product in MCode/TCP mode, this tool is primarily used to set the
device IP address and test connectivity and functionality before using IMS Terminal for configuration and programming.
IMS Terminal
IMS Terminal is an Integrated Program Editor and Terminal Emulator
designed to communicate with and program IMS products including
the MCode devices, the Motion Control MDrive, MForce and Hybrid
products. For purpose of this document the focus will be on the devices
utilizing the MCode language.
The upgrader utility included with IMS Terminal is required if you desire
to upgrade the firmware in your MCode device.
6.1.2
Features
General features

Multiple program editor windows allowed.

Multiple Terminal Windows allowed which can be connected to
multiple devices and device types.

Configurable initialization file (lynxterm.lxt) allows Program
Editor and Terminal Window states and configurations to be
remembered and opened upon startup.

Color-coded text to easily differentiate command types.

Auto-indent for program blocks.

Lines of code my be commented using the apostrophe (‘) character.

Files may be text (*.txt) formatted or MCode (*.mxt) formatted.
Note the color-coded text is only available in the MCode format.

Color-coding, indenting, font type, size and style are user configurable through the preferences dialog.

Programmable function keys set in groups of ten.

Multiple function key groupings.

Special “Capture Mode” allows the capture of all terminal communications to a text file.

Terminal Window Status, i.e. Connected/Disconnected, Port #,
BAUD Rate and etc. displayed on a clickable bar across the bottom of the Terminal Window.
Program editor window
Revision R062812
Terminal emulator window
6-1
6 Supporting Software
6.1.3
MCode Programming and Software Reference
Installing IMS Terminal
System requirements

IBM Compatible PC.

Windows XP Service Pack 2 or greater.

A free USB or serial communications port.
1)
Download the software from the IMS web site at
http://motion.schneider-electric.com/downloads/software_interfaces.html.
2)
Extract to a location on your hard drive.
3)
In the folder location of the extracted files, double click “setup.
exe”
4)
Follow the on-screen prompts to complete the installation of IMS
Terminal.
Installation
6.1.4
Screen and menu overview
IMS Terminal main screen
Terminal Emulator
Window
Program Editor
Window
Programmable Function Keys
F1 - F10
Capture On/Off
NumLock Off/On
CapsLock Off/On
Insert/Overstrike
Connected/Disconnected
Row #
Column #
Port # : BAUD Rate
Connected Device
Revision R062812
Function Key Group #
Figure 6.1 IMS Terminal main screen
6-2
MCode Programming and Software Reference
6.4.2
6 Supporting Software
The menu bar structure and operation
Most of the functions of the IMS Terminal are accessible through the
menu bar. Please note that some of the menu bar functions will differ
based upon the type of window which is active, either Program Editor or
Terminal.
File menu functions
6.4.3
File menu functions functions, when used in the program editor, are
common to most windows programs. When the terminal window is in
an active state, the new, open and save items will disable. Save as will
allow the user to save the contents of the terminal window, including the
scroll back buffer, if desired to a text file.
Edit menu operation
As with the file menu, many of the edit menu functions are familiar to
windows users such as redo, undo, copy, cut, paste, delete, select all,
find, find next and replace. These will function as they do with other
windows-based software programs. Of these, only copy and paste will
be available if a terminal window is active.
Preferences
The preferences item will open a tabbed dialog with the various window
configuration settings. If selected with the program editor window active,
it will display the font, color, style selections for the program window.
If selected with the terminal window active, it will display the visual configurations settings for the terminal window. These configurations will be
discussed in detail later in this section.
Open preferences
The preferences settings are all saved in a single *.ltm file, the default
being lynxterm.ltm. These files contain the following preference settings:

Text editor preferences

Program editor preferences

Terminal format preferences

Terminal window communications settings

Open program or text files

Open terminal windows

Function key and group configuration
IMS terminal will automatically save the settings on exit to the filename
you have loaded.
Revision R062812
Save preferences

Save preferences will save the current preferences to the
loaded file.

Save preferences as

Save preferences as different *.ltm filename.
6-3
6 Supporting Software
MCode Programming and Software Reference
View menu operation
The only applicable functions to MCode devices are the menu items:

New edit window

New terminal window
The operation of these options are covered later in this section
Transfer menu operation
The transfer menu controls the transfer of data to and from the MCode
device.
Upload
Upload will open a dialog which will allow the user to selectively transfer
the stored global variable and flag declarations and programs to a new
or open program editor window.
Download
The download menu item will open a dialog allowing the user to selectively download variable and flag declarations and programs to the
MCode compatible device from either an open program editor window or
a saved *.mxt file.
Capture
The capture menu item will place the active terminal window into a
special “capture mode”. When in capture mode all terminal activity is
captured to a text file in real time. The on/off state of capture mode is
displayed on the bottom indicator bar of the active terminal window.
When in capture mode, two additional menu items appear on the transfer menu:

Pause capture

Stop capture
These will function as described by their label.
Upgrade menu operation
The upgrade! menu item will open the IMS Terminal upgrader utility
for upgrading the firmware in your MCode device. It will not place your
device in the upgrade mode for upgrading.
Window menu operation
Revision R062812
The Window menu offers the options common to most Microsoft Windows™ programs.
6-4
MCode Programming and Software Reference
6.1.5
6 Supporting Software
Configuring IMS Terminal
Configuring program editor format
preferences
The program editor features a number of enhancements designed to aid
the user in programming IMS MCode products by the use of color-coded
text and automatic tabbing to separate program blocks and subroutines
for easier code editing and debugging.
While the default format of the program editing window is sufficient for
most users, you may configure the format to your preference.
To open the program editor preferences dialog:
1)
Right-click into the program editor window.
2)
Select preferences.
3)
The program editor format tab of the preferences dialog will
open.
4)
Set the format to that which you desire.
Note that the use of a mono-spaced font such as the default, courier
new, makes code editing and debugging much easier than using a variable spaced font.
Configuring terminal window format
preferences
The terminal window features similar formatting preferences as the
program editor.
To open the terminal format preferences dialog:
2)
Right-click into the terminal window.
3)
Select preferences.
4)
The terminal format tab of the preferences dialog will open.
5)
Set the format to that which you desire.
Revision R062812
1)
6-5
6 Supporting Software
MCode Programming and Software Reference
Configuring communications settings
The communications settings are configured by means of the preferences dialog.
The optimum communications settings for the MCode compatible device are set by default. The only thing that will need to be set to begin
communicating with your MCode device is to set the COM port to which
your rs-422/485 communications converter is connected, or the IP address if using an Ethernet based product (default 192.168.33.1).
1)
Open the communications preferences dialog by either opening the preferences from the menu bar and selecting the comm
settings tab, or double clicking the port: baud rate field on the
status bar at the bottom of the terminal window.
2)
Select the device you are communicating with:
MDI - MDrive or MForce
ASI - Hybrid
The communication settings will automatically be set for the
device selected.
3)
The window size and function key settings are optional.
4)
Once you have selected the correct com port, click ok.
5)
Verify hardware connections and apply power to the MCode
device.
6)
If not already connected, connect to the device by clicking the
“connect” icon on the button bar, or by double clicking the disconnected field on the status bar of the terminal window.
7)
Key in ctrl+c.
8)
The sign-on message below should appear.
The sign-on message should appear:
Copyright 2001 - 2010 by Schneider Electric Motion USA
>
Revision R062812
The sign-on message indicates that you are up and running. You may
now begin to issue immediate mode commands and/or download programs to your device!
6-6
MCode Programming and Software Reference
6.1.6
6 Supporting Software
Troubleshooting communications
Troubleshooting the communications
converter
1)
Go to the start menu on Windows XP.
2)
Right click “my computer”, select “properties”.
3)
On the system properties dialog, click the tab labeled “hardware”.
4)
Click the device manager button.
5)
On the device manager window, click the “+” sign next to ports
(com and lpt) to expand the category.
6)
The RS-422 converter should be listed there with its port number.
7)
Verify that the port is the one configured in the communications
settings for IMS Terminal.
8)
If the communications converter does not show in the device
manager verify that the drivers for the converter are installed per
the converter manufacturer documentation.
9)
If the converter will not install, contact the device manufacturer
support desk.
10)
Communications converter installed and functioning
11)
Verify that all mating connectors are firmly seated.
If not using an IMS MD-CC40x-001 and appropriate adapter, verify the
wiring.
Check the following connections:
Converter
MCode Device
RX+ ........................................................................................... TX+
RX- ............................................................................................. TXTX+ ............................................................................................ RX+
TX- ..............................................................................................RX-
Revision R062812
GROUND................................................................................ CGND
6-7
6 Supporting Software
6.1.7
MCode Programming and Software Reference
Configuring function keys
The ability to program MCode functions and code strings and assign a
function key to them is one of the most powerful features of IMS Terminal.
Function Keys can also be grouped in whatever fashion the user desires. IMS Terminal supports up to 999 function groups.
The illustration below shows the function key dialog with example functions programmed in.
To open the function key dialog:
Right-click any of the function keys on the bottom of the terminal window or key-in CTRL+[F1-F10].
Caption (brief description)
Contents (MCode commands)
Control Options Menu
Function Group Name
Function Group Selection Button
Revision R062812
Figure 6.2 Function key setup dialog
6-8
MCode Programming and Software Reference
6 Supporting Software
Function key control commands
The IMS Terminal function keys have a number of control commands
that are used to input or impact MCode strings sent to the terminal on
function key press.
Function
Characters
Description
Control C
^C
MCode Software Reset
Bell
^G
Computer Beep
Tab
^t
Tabs cursor 5 spaces
Line Feed
^J
Sends a Line Feed
Carriage Return
^M
Sends a Carriage Return
Cr/Lf
^M^J
Sends a Carriage Return with a Line Feed
Escape
^[
Sends an Escape
Pause (1 Sec)
^p
Pauses operation between command execution for 1 second
Pause (50 mSec)
^m
Pauses operation between command execution for 50
milliseconds
Pause (Time mSec)
^d<x>
Pauses operation between command execution for <x>
milliseconds
Repeat (Count)
^r<x>
Repeats the string <x> times
Capture ON
^c
Turns on the IMS Terminal Capture Feature
Capture OFF
^o
Turns off the IMS Terminal Capture Feature
Function Key
^f<1-10>
Activates Function Key <1-10>. Can be used to send multiple
command strings from the functions.
Timer On
^t1
Activates Timer. Time will display on the status bar. The Time
will not update until the Timer is turned off
Timer Off
^t0
Deactivates Timer, updates time display on status bar.
Revision R062812
Table 6.1 Function key control commands
6-9
6 Supporting Software
6.1.8
MCode Programming and Software Reference
Creating, downloading and uploading programs
Existing programs may be edited in the program editor window from a
file on a disk, a file on the hard drive or a file uploaded from an MCode
compatible device. You may also create a new program in the program
editor window.
Note: your system must be connected and running to perform these
steps as they are outlined.
Creating a new program
Before you create a program you must have a new program editor
window open. Follow these steps:
1)
Click on the drop-down menu “view”. The following dialog box
will be displayed:
2)
Click on “new edit window”.
3)
You must assign a file name in order to open the new window.
If there is no file name the “ok” button will not be highlighted.
Name this file <my program.mxt>. The <mxt> extension designates MCode programs.
4)
Click “OK” and the new program editor window will be displayed.
Naming the program with the <mxt> extension automatically formats
the text color and makes most of the characters appear in upper case.
When you type a program the text will be color coded. In complex programs it may be difficult to read the text easily. By formatting indents,
the overall appearance and readability will be greatly improved.
Downloading a program to the device
NOTE: Before downloading any programs type FD into the terminal
window and press ENTER to set the device to the factory defaults.
There are two basic sources from which you can download programs to
the MCode compatible device:
1)
Directly from the program editor window of the IMS Terminal.
2)
From a file folder located on a hard drive or removable disk.
To download
1)
2)
Activate the Program Editor Window containing the Program
MR.mxt.
Click the menu item “Transfer > Download”. The download
Revision R062812
dialog box will open.
6-10
3)
Click the download button on the main tool bar. The download
dialog box will open. Select the “Source Type > Edit Window”
option, and click download. The program will transfer to the
device. If a program has been previously created and stored, it
may be downloaded to the device from the *.mxt file.
4)
Once the program is downloaded, type S and press ENTER to
MCode Programming and Software Reference
6 Supporting Software
Save the program. (Always save your programs!)
5)
Now type EX 1 and press Enter or Click the Function button Run
PGM 1. (EX=Execute and 100 is the Program Number.) The
motor should move a short distance back and forth.
NOTE: The program can be stopped by pressing the escape button or
by pressing <Ctrl+C>.
Uploading a Program
NOTE: Be certain the program is stopped by pressing the Escape Button or by pressing <Ctrl+C>.
There are two ways to upload programs from the MCode compatible
device:
1)
Directly to the program editor window of the IMS Terminal.
2)
To a file folder located on a hard drive or removable disk.
There are also two ways to enable the upload dialog box.
1)
Click the menu item “Transfer > Upload”. The upload dialog box
will open.
2)
Click the upload button on the main tool bar. The upload dialog
box will open. The upload dialog box is similar in appearance to
the download dialog box.
With the upload dialog box open, select the “Destination Type > Edit
Window” option, click “Upload”. The program will transfer from the
device.
Programs may also be uploaded from the device directly to a text file by
selecting “Destination Type > “File” as the destination and typing in a
filename in the “File Name” box on the dialog box.
NOTE: When uploading MCode program files they will be slightly
changed from the original. The device will upload the program only with
the data within the program. That is, the data between the two program
modes (PG). Data such as variables entered outside the PG modes
will not be uploaded. The uploaded program will also have a header
‘[PROGRAMS] and a footer ‘[END]. These will not affect your program
as they are remarked with the apostrophe (‘) or they can be removed
during editing.
Revision R062812
You may upload the program variables by clicking “Variables” in the
upload dialog box. However, this will upload all of the current variables,
not just those associated with the program.
6-11
6 Supporting Software
6.1.9
MCode Programming and Software Reference
Program troubleshooting using IMS Terminal
The IMS Terminal offers tools to help you troubleshoot and analyze
programs. They are:

Execute in single step mode

Execute in trace mode

The scroll back function

The capture function
Single step mode
The single step mode allows the user to execute a program in the immediate mode one line at a time. This will help the user to define problem
areas by process of elimination. To use single step mode, do the following:
It is recommended that you list (L) the program in the terminal window
and either print it on paper or cut and paste it to another program edit
window. This will allow you to look ahead and see what line is coming
up next.
1)
Have the system and the program ready to run.
2)
To run in single step mode add a comma and the number two
(2) to the execute command.
Example: the program label is <aa>. Type EX aa,2. The program will
run one line at a time.
3)
Each line will be executed and listed in the terminal window and
the program will stop.
4)
To execute and list the next line, press the space bar.
5)
Press the space bar for each successive line until the program
has completed.
While the program is executing, it will stop after each line is listed. At
this time you may enter immediate commands such as velocity variables
or actual moves as tests within the program. After entering immediate
commands you may continue running in single step mode by pressing
the space bar again.
If you decide to cancel the single step mode press the “enter” key and
the program will run in normal mod and finish or press escape (esc) to
abort the program.
Trace mode
Revision R062812
The trace mode allows the user to run a program and list each line as
it is executed. Running trace mode in conjunction with the scroll back
function or the capture function will enhance your program troubleshooting tasks. To run trace mode:
1)
Have the system and the program ready to run.
2)
To run in Trace Mode add a comma and the number one (1) to
the execute command.
Example: the program label is <aa>. Type ex aa,1. The program
will run in trace mode and each line will be executed and listed in
the terminal window.
3)
6-12
Each line can now be analyzed.
MCode Programming and Software Reference
6 Supporting Software
On very large programs all of the lines may not be displayed if the
“Scroll Back Buffer” value is set too low. The Scroll Back Buffer can be
set to a higher value allowing you to Scroll Back farther in the program.
The capture function
The capture function allows you to capture terminal communications into
a text file for the purpose of troubleshooting. You may have a program
that fails after running a number of times. It may be from an accumulation of position errors or other factors. By enabling the capture function
you can store an entire text file of the received communications to your
hard drive for analysis.
Enable the capture function
The Capture function may be enabled through the drop-down menu
under “Transfer”.
When you click on “Capture” a dialog box will be displayed.
Give the file you will be capturing a name and be certain to save it as
a [ .txt ] file and click “Save”. Upon clicking Save, the faded (disabled)
Capture title below the Function Keys will change to “Capture ON” and
to black letters.
Revision R062812
You are now ready to run the program. The program in this example will
cycle five (5) times. The data will scroll up the Terminal Window while a
copy of the data is captured into the text file simultaneously.
6-13
6 Supporting Software
6.1.10
MCode Programming and Software Reference
Upgrading firmware
Before upgrading the MCode firmware
IMPORTANT! It is recommended that you review this procedure in its entirety before performing the upgrade.
It is recommended that the most recent version of IMS Terminal Software be installed on your PC prior upgrading the firmware.
To check if you have the most recent version of IMS Terminal Software,
click the “HELP” menu item on the IMS Terminal menu bar and then
click “About IMS Terminal”. The following information block will appear.
The current version of your IMS Terminal Software will be shown as
indicated by the arrow. Compare this version number with the IMS Terminal version number found on the IMS web site at motion.schneiderelectric.com/software_interfaces.html. If a more recent version is shown
on the web site, you should download and install it on your system
before upgrading the firmware.
NOTE: The file you will be downloading is a self-extracting executable
file. Download it to your desktop or a known folder.
To install the most recent version of IMS Terminal Software on your
system perform the following steps:
Revision R062812
NOTE: Skip Steps 1 & 2 if this is a new installation.
6-14
1)
Open Windows Explorer and proceed to the folder “Program
Files”.
2)
Locate the folder named “IMS Terminal” and rename it to “IMS
TermOLD”. This will preserve any files you want to save which
can be retrieved later and it will also ensure a complete new
installation of IMS Terminal.
3)
Locate the downloaded version of IMS Terminal Software and
Double Click the file.
4)
A message regarding sharing files will appear. All other applications should be closed. Click OK.
5)
In the window that follows, click the button to the left of the message to continue.
6)
A dialog box will query you as to which program group you want
IMS Terminal to be associated. Click CONTINUE to accept the
default.
7)
The installation will begin followed by the “Installed Successfully”
message box. Click OK and the system is ready.
MCode Programming and Software Reference
6 Supporting Software
Upgrading the firmware
NOTE: Your MCode compatible device is configured with the most
recent firmware at the time of shipment. The main reason for upgrading is to take advantage of new features that your system may need or
to correct minor errors that may be causing problems in your system.
Albeit, new features and corrections may be appealing, they may have
little or no affect on your system operation. If your system is operating
as it should, be hesitant about upgrading the firmware for the sake of
“upgrading”. Before performing the upgrade procedure, verify the firmware version.
With the system running, type <pr vr> in the Terminal Window and press
ENTER. The device will return the firmware version number. Compare this number with the latest version on the IMS web site at motion.
schneider-electric.com/flash_code.html.
While at the web site, review the Change Summary for that version of
the firmware. If none of the changes will help to correct a problem you
may be having or improve your system operation, it is not necessary to
upgrade.
Many problems are the result of programming errors. Verify that you do
not have a programming problem that may mislead you to believe there
is a problem with the firmware or your system.
If it is determined that a firmware upgrade is necessary, download the
most recent version into a known folder from http://motion.schneiderelectric.com/downloads/firmware.html.
During upgrades, the communication baud rate is switched from 9600 to
19,200 and is more susceptible to electrical noise. Your communications
cable should be kept to a minimum length of 6 feet.
When using a laptop PC it is recommended that you power the RS-232
to RS-485 cable with an external +5 VDC power supply. This will fortify
communications.
The device remains in the upgrade mode until the upgrade is complete.
Cycling power will not clear the upgrade mode.
Revision R062812
It is recommended that you use this procedure as it is tailored for the
device while the on-screen instructions are designed for several different products.
6-15
6 Supporting Software
MCode Programming and Software Reference
1)
Open “IMS Terminal”. The following screen should be displayed.
The left panel is the program edit window and the right panel is
the terminal window. The firmware upgrade will superimpose
several dialog boxes and instructions over these two windows.
2)
Check to see that the terminal window is set for communication.
3)

Right click in the terminal window.

Click “Preferences” near the bottom of the pop-up menu.

A “Preferences” dialog box will be displayed.

Click on the “Comm Settings” tab at the top of the box.

Confirm that device is selected in the “Devices” block.
MDI - MDrive or MForce
ASI - Hybrid
Power up the device.

The sign on message will appear.
“Copyright 2001-20010 by Schneider Electric Motion
USA.”
4)
Check and/or reestablish communications if the sign on message does not appear.
5)
Type UG 2956102 in the terminal window and then press <enter>. Include the space between the G and the 2.

The device will return a random symbol character (ô or ö)
when it is in the upgrade mode.
6)
Click the “Upgrade” menu item on the IMS Terminal menu bar.
7)
Message appears: “During upgrade, the baud rate is changed to
19,200.”

8)
9)
Click “OK”
The Windows Explorer page “Select device upgrade file” opens.

Browse and select the desired version of the upgrade file.

Click “Open” or double click the file.
Message appears: Step 2 Select upgrade file.

The upgrade version will now appear in the upgrade version window.

Click “Next”
10) Message appears: Step 3 Reminder Press cancel if you need to
setup COMM port.

The COMM port has been setup previously. This is just a
reminder.

Click “Next”
11) Message appears: Step 4 Connect RS-422 cable to the
device.
Revision R062812

6-16
The RS-422 has been connected previously. DO NOT
perform this step.
MCode Programming and Software Reference

6 Supporting Software
Click “Next”
12) Message appears: Step 5 If device is not in the upgrade mode,
press cancel then type ‘UG 2956102’ in the terminal window.

The device was placed in the Upgrade mode previously.
DO NOT ENTER CODE AGAIN.

Click “Next”
13) Message: Step 6 Power up or cycle power to device.

The unit has been previously powered up. Do not cycle
power.

Click “next”
14) Message: Step 7 Establishing COMM with device.

Wait for step 8 to appear.

The previous version of firmware will now be displayed in
the “Previous Version” window.
15) Message: Step 8 Press upgrade button to start.

Click the upgrade button.

NOTE: An upper case E will be displayed in the “Type
Number” window. This confirms the upgrade is functioning properly.
16) Message: Step 9 Press ABORT to abort upgrade.

DO NOT abort the upgrade. The device remains in the
upgrade mode and the upgrade must be completed.

Monitor the progress in the “Upgrading…%” window.

Step 10 will appear when DONE
17) Message: Step 10 Resetting device. Then Press DONE.

Click “DONE”

Upgrade window will close.
18) Press “Control + C” <Ctrl + C> while the Terminal Window is
active to reset the device and exit the upgrade mode.

The sign on message will appear. “Copyright 2001-2008
by Intelligent Motion Systems, Inc.”

The > cursor will appear.
19) The device firmware has been upgraded.
20) Optional confirmation of the upgrade: Type “PR VR” in the
terminal window and press <enter>.
The new firmware version is displayed.
Revision R062812

6-17
6 Supporting Software
6.2
MCode Programming and Software Reference
TCP/IP Configuration Utility
The TCP/IP Configuration Utility is specifically for setting the Ethernet
MDrive Motion Control IP address and basic functionality testing for use
with MCode/TCP. We recommend using IMS Terminal for programming
and controlling the MDrive after initial TCP/IP configuration.
6.2.1
Installation
System requirements

IBM Compatible PC.

Windows XP Service Pack 2 or greater.

Ethernet hub with free port.
1)
Download the software from the web site at
http://motion.schneider-electric.com/downloads/software_interfaces.html.
2)
Extract to a location on your hard drive.
3)
In the folder location of the extracted files, double click “setup.
exe”
4)
Follow the on-screen prompts to complete the installation.
Installation
6.2.2
Screen overview
Configuration
SEM Port (Terminal)
Revision R062812
Figure 6.3 TCP/IP Configuration Utility
6-18
MCode Programming and Software Reference
6 Supporting Software
For MCode/TCP two of the 4 tbs on the GUI are available: The MODBUS and Manual tabs will generate an error dialog if you attempt to
access them in MCode/TCP mode.
6.2.3
1.
Config: Used to read the device MAC address and read/write the IP
address and netmask.
2.
SEM Port: a lightweight terminal emulator for testing the communication setting.
Configuration
The primary function of the utility in MCode/TCP mode is to configure the device IP address and
Subnet Mask.
If you are on a corporate network, you may need to check with your IT department to obtain
a block of private IP addresses so as not to conflict with computers and other devices on the
network.
The assigned IP address should always be within the IPv4 Private Network block (192.168.0.0 —
192.168.255.255).
MCode/TCP will always use port 503 and may communicate via TCP or UDP interchangeably.
MAC Address: Preset at
factory. Cannot be changed
IP / Subnet :
Modify to suit the configuration
of your network. Default:
192.168.33.1/255.255.0.0
Revision R062812
Figure 6.4: Configuration tab
6-19
6 Supporting Software
6.2.4
MCode Programming and Software Reference
SEM Port tab
This tab is used to test the functionality of communication interface and can submit commands to
the MDrive
Schneider Elecric Motion USA
Terminal: Echo and
response here.
Command entry:
MCode commands can
be entered here
Revision R062812
Figure 6.5: SEM Port tab
6-20
MCode Programming and Software Reference
6.3
6 Supporting Software
Upgrading the Ethernet controller firmware
NOTE: This refers strictly to the controller firmware for the Ethernet
interface of Ethernet equipped MDrivePlus and MDrive Hybrid models. It
is NOT an upgrade to the MDrive operating firmware.
It is recommended that you DO NOT perform this upgrade unless so
instructed by the IMS SEM Applications department.
Please review this in detail before performing the upgrade, each step
must be completed in order.
Requirements
The latest versions of the software and firmware are available on the
web site under the downloads tab at http://www.schneider-electricmotion.us
1)
MDrivePlus or MDrive Hybrid Motion Control with Ethernet
2)
TCP/IP Configuration Tool (Installed)
3)
TFTPD Firmware Server (Installed)
4)
Ethernet firmware upgrade file
IMPORTANT: Unzip upgrade *.S19 file to the installation directory of the TCP/IP Configuration Tool
This process will utilize the firmware upgrade area on the configuration
tab of the TCP/IP Configuration Tool to set up.
Config Tab
Revision R062812
Firmware upgrade
area
Figure 6.6: TCP/IP Config tab
6-21
6 Supporting Software
6.3.1
6.3.2
MCode Programming and Software Reference
To begin
1)
Open the TCP/IP Configuration Tool
2)
Click the config tab, if not already active.
3)
Connect to your Ethernet MDrive over TCP.
Set the Tftpd Server IP
a)
Click “Get Local IP”
b)
Click “Write”
c)
Tftpd Server IP should read ‘OK’
c
b
a
Figure 6.7: Setting the Tftpd Server IP
6.3.3
Set the Ethernet upgrade file name
a)
Click “Browse & set file name”. In the file open window, browse
to the location where you extracted the firmware upgrade *.S19
file. Click “OK”
b)
Click “Write”
c)
Ethernet Upgrade File Name should read ‘~OK’
c
Revision R062812
b
a
Figure 6.8: Setting the upgrade file name
6-22
MCode Programming and Software Reference
6.3.4
6 Supporting Software
Enter upgrade mode
1)
On the «Edit» menu, select «Enter Ethernet Firmware Upgrade
Mode»
2)
A dialog will open requesting verification of the upgrade filename. If the name matches, click «Yes».
3)
If it does not match, click «No» and repeat step 2.
4)
In the dialog, «Enter unlock code to enter upgrade mode»,
enter the code:
2956102
6.3.5
5)
The message, «Successfully entered Ethernet Firmware upgrade mode» will appear, click «OK».
6)
The message «Cycle power to upgrade Ethernet firmware via
Tftpd server» will pop up. DO NOT Click OK at this point.
Complete upgrade process
1)
Remove power from you MDrive.
2)
Click “OK” on the dialog referenced in Step 3-e.
3)
On the “Edit” menu, select “Select & Enter Tftpd Server”.
The browse dialog should open to the install directory. If not,
browse to the Tftpd_Server install directory and select “tftpd32.
exe”
4)
Click “Open”
5)
Apply power to the MDrive
6)
The upgrade should begin after a few seconds.
7)
When complete, close Tftpd server.
8)
Cycle power to the MDrive.
9)
Reconnect using the default IP: 192.168.33.1 and Subnet
mask: 255.255.0.0.
Revision R062812
10) Configure device to your system requirements.
6-23
6 Supporting Software
MCode Programming and Software Reference
Revision R062812
Figure 6.9: Firmware upgrading
6-24
MCode Programming and Software Reference
7
7 Programming and Application Notes
Programming and application notes
This section will cover the following areas of MCode programming and
applications in detail.
7.1

Party mode communications

Programming the I/O

Factors impacting motion commands

MForce PWM configuration
Party mode communications
The following communication formats, used by MCode comptible devices.
{}
............. The contents between the {} symbols are transmitted.
{0D} .............................Hex equivalent for a CR (Carriage Return).
{0A} ....................................... Hex equivalent for a LF (Line Feed).
{DN} .............................. Represents the Device Name being sent.
{CS} ............................. Check Sum; {ACK} 06 Hex; {NAK} 15 Hex
EM = Echo Mode; PY = PartY Mode; CK= ChecK sum
The word {command} represents the immediate command sent to the
device.
Command execution time (CET) is the time the device takes to execute
a command. This varies from command to command and usually is in
the 1-5 millisecond range.
7.1.1
Response to Echo Mode
Revision R062812
Dependent on how the echo mode (EM) is set in conjunction with party
mode (PY) and check sum (CK), the device will respond differently. The
following tables illustrate the various responses based on how the EM,
PY and CK parameters are set.
7-1
7 Programming and Application Notes
Parameter Setting
MCode Programming and Software Reference
Transmission
Initial Response
EM=0 & PY=0 CK=0 (command) (D)
EM=1 & PY=0 CK=0 (command) (0D) −
CET (0D) (0A)
The last
character sent
is LF
EM=2 & PY=0 CK=0 (command) (0D) −
−
No response
except to PR and
L commands
EM=3 & PY=0 CK=0 (command) (0D) −
CET command
(0D) (0A)
Queued
response. The
last character
sent is the LF
Table 7.1
Revision R062812
Response to echo mode - party and check sum are zero (0)
Final
Response
Notes
(DN) (command)
(0A)
(command)
Echoed back one
character at a time
as the character is
entered.
CET (0D) (0A)>
The last
character
sent is the
prompt >
EM=1 & PY=1
CK=0
(DN) (command)
(0A)
−
CET (0D) (0A)
The last
character
sent is LF
EM=2 & PY=1
CK=0
(DN) (command)
(0A)
−
No response
except to
PR and L
commands
Transmission
Initial Response
EM=0 & PY=1
CK=0
Parameter Setting
7-2
Final Response Notes
(command)
The last
Echoed back one
CET (0D) (0A)> character sent is
character at a time as
the prompt >
the character is entered.
−
MCode Programming and Software Reference
EM=3 & PY=1
CK=0
(DN) (command)
(0A)
Table 7.2
Parameter Setting
CET command
(0D) (0A)
−
Queued
response.
The last
character
sent is the LF
Response to echo mode - party is one (1) and check sum is zero (0)
Transmission
Initial Response
Final Response
Notes
EM=0 & PY=0
CK=1
(DN) (command)
(0A)
(command)
Echoed back one
character at a time
as the character is
entered.
EM=1 & PY=0
CK=1
(DN) (command)
(0A)
−
CET (0D) (0A)
The last
character
sent is LF
EM=2 & PY=0
CK=1
(DN) (command)
(0A)
−
−
No response
except to
PR and L
commands
CET command
(0D) (0A)
Queued
response.
The last
character
sent is the
LF
EM=3 & PY=0
CK=1
(DN) (command)
(0A)
Table 7.3
Parameter Setting
Revision R062812
7 Programming and Application Notes
The last
character
sent is the
prompt >
Response to echo mode - party is zero (0) and check sum is one (1)
Transmission
EM=0 & PY=1
CK=1
(DN) (command)
(CS) (0A)
EM=1 & PY=1
CK=1
(DN) (command)
(CS) (0A)
EM=2 & PY=1
CK=1
(DN) (command)
(CS) (0A)
EM=3 & PY=1
CK=1
−
CET (0D) (0A)>
(DN) (command)
(CS) (0A)
Final
Response
Initial Response
Notes
(command)
Echoed back one
character at a time
as the character is
entered.
CET (ACK) or
(NAK)>
The last
character
sent is the
prompt >
−
CET (ACK) or
(NAK)>
The last
character
sent is ACK
or NAK
−
−
No response
except to
PR and L
commands
−
CET
command
(CS) (ACK)
(NAK)
Queued
response.
The last
character
sent is ACK
or NAK
Table 7.4: Response to echo mode - party and check sum are one (1)
7-3
7 Programming and Application Notes
7.1.2
MCode Programming and Software Reference
Using Check Sum
For communication using check sum, the following 2 commands demonstrate sending and receiving.
1)
Check sum set to zero before first character is sent.
2)
All characters (ascii values) are added to check sum, including
the device name DN (if PY=1), to the end of the command, but
not including terminator.
3)
Check sum is 2’s complement, then “or” ed with hex 80 (prevents check sum from being seen as command terminator).
4)
Terminator sent.
Note: Any combination of upper/lower case may be used. In this example, if a lower case <mr> were to be used, the decimal values will
change to 109 and 114. Subsequently the result check su m value will
ch a n g e . (Po ssi b l e e n tri e s: MR , mr, Mr, mR .) (M = 77, R
=8 2 , m = 109, r = 114) (See ASCII table in Section 9 of this document.)
77 82 32 49
Decimal value of M, R, <space> and 1
4D 52 20 31
Hex
77+82+32+49 = 240
Add decimal values together
1111 0000 = 240 Change 240 decimal to binary
0000 1111 1’s complement (invert binary)
0001 0000 Add 1 [2’s complement]
1000 0000 OR result with 128 (Hex 80)
1001 0000 144
Result Check Sum value
Once the result is reached, add the check sum value (144 in this example) to your string by typing: MRr 1(alt key + 0144) (use the symbol
of 0144 in your string by holding down the alt key and typing 0144).
You must type the numbers from the numlock key pad to the right of the
keyboard. The numbers at the top of the keyboard will not work.
1)
Check sum set to zero.
2)
All characters are added to check sum.
3)
When receiving a command terminator, the lower 7 bits of the
check sum should be equal to zero.
A) if not zero, the command is ignored and NAK echoed.
B) if zero, ACK is sent instead of CR/LF pair.
4)
Revision R062812
7.1.3
Responses to PR commands will be check summed as above,
but the receiving device should not respond with ACK or NAK.
Immediate party mode sample codes
Once party mode has been defined and set up as previously described
under the heading “multiple devices (party mode)”, you may enter
commands in the immediate mode in the ims terminal window. Some
examples follow.
7-4
MCode Programming and Software Reference
Move device A, B or C 10000 steps
7 Programming and Application Notes
Assuming there are three devices set up in party mode as shown in the
sample codes above.

To move mdrive unit “a”, press CTRL+J and then type:
aMR^10000 and pressCTRL+J. device “a” will move 10000
steps.

To print the position type: aPR p and press CTRL+J. The position of device “a” will be printed.

To move device “b” type: bMR 10000 and press CTRL+J. Device “b” will move 10000 steps.

To move all three devices at the same time type: *MR 10000
and press CTRL+J. All devices will move 10000 steps.

To change a variable in the “c” unit type: c<variable
name><number> and press CTRL+J. The variable will be
changed. To verify the change type: cPR <variable name> and
press CTRL+J. The new value will be displayed.

All commands and variables may be programmed in this manner.

To take a device out of party mode type: <device name>PY=0
and press CTRL+J. That unit will be taken out of party mode. To
take all units out of party mode type: *PY=0 and press CTRL+J.
All units will be taken out of party mode.
7.2
Programming the I/O
7.2.1
I/O availability per device type
The product families using the MCode language may have different sets
of I/O points and functions. These are
MDrive, MForce
MDrive, MForce, (Plus2 expanded features)
4 +5 to +24 VDC I/O points programmable as sinking or sourcing inputs or sinking outputs.

1 analog input.

8 +5 to +24 VDC I/O points programmable as sinking or sourcing inputs or outputs.

1 analog input.

2 TTL level step/direction I/O programmable as sinking or sourcing inputs or outputs.

1 TTL level high speed point programmable for capture input or
trip output functions

4 +5 to +24 VDC I/O points programmable as sinking or sourcing inputs or outputs.

1 analog input.
Revision R062812
MDrive, MForce (Plus2 expanded features
with remote encoder inputs)

7-5
7 Programming and Application Notes
MDrive Hybrid
7.2.2
MCode Programming and Software Reference

6 TTL level differential encoder inputs.

1 TTL level high speed point programmable for capture input or
trip output functions.

EXCEPTION: MDrive34Plus2 and MForce PowerDrive Plus2 are
available with 8 sinking/sourcing I/O points and remote encoder
inputs.

8 +5 to +24 VDC I/O points programmable as sinking or sourcing inputs or outputs.

1 analog input.

1 TTL level high speed point programmable for capture input or
trip output functions
Active states defined
The active state determines at what voltage level the input will be active.
Active HIGH: the input will be active when +5 to +24 VDC is applied to
the input.
Active LOW: The input will be active when it is grounded (0 VDC).
Examples
IO 1 is to be configured as a Jog– input which will activate when a
switch is toggled to ground (sinking input):
S1=8,0,0
‘set io point 1 to jog–, active low, sinking
IO 4 is to be configured as a home input which will activate when instructed by a PLC (+24VDC sourcing input):
Revision R062812
S4=1,1,1
7-6
‘set io point 1 to home, active high, sourcing
MCode Programming and Software Reference
7.2.3
7 Programming and Application Notes
Digital input functions
The inputs may be interfaced to a variety of sinking or sourcing devices.
An input may be programmed to be a general purpose user input, or to
one of nine dedicated input functions. These may then be programmed
to have an active state of either high or low.
The inputs are configured using the “S” variable (see Section 5: Command details). The command is entered into the ims terminal or program
file as:
s<io point>=<io type>,<active state><sink/source>.
Example:
S9=3,1,0
S3=0,0,1
Revision R062812
Input Functions (I/O Points 1-4, 9-12)
‘set io9 = limit- input, active high, sinking
‘set io 3 = general purpose input, active low,
‘sourcing
The following table lists the programmable input functions.
Function
Description
Parameter
(S1-S4, S9-S12)
Active
Sink/
Source
General Purpose
General purpose input function
used to control program branches,
subroutine calls or bcd functions
when input bank is used as a
group
0
0/1
0/1
Home
Homing input. Will function as
specified by the home (hm)
command.
1
0/1
0/1
Limit +
Positive limit input. Will function
as specified by the limit (lm)
command.
2
0/1
0/1
Limit –
Negative limit input. Will function
as specified by the limit (lm)
command.
3
0/1
0/1
G0
G0 input. Will run program located
at address 1 on activation.
4
0/1
0/1
Soft Stop
Soft stop input. Stops motion with
deceleration and stops program
execution.
5
0/1
0/1
Pause
Pause/resume program with
motion.
6
0/1
0/1
Jog +
Will jog motor in the positive
direction at max. Velocity (vm).
The jog enable (je) flag must be
set for this to function.
7
0/1
0/1
Jog –
Will jog motor in the negative
direction at max. velocity (VM).
The jog enable (JE) flag must be
set for this to function.
8
0/1
0/1
Reset
When set as reset input, then the
action is equivalent to a ^c entered
into a terminal.
11
0/1
0/1
Table 7.5
Digital input functions
7-7
7 Programming and Application Notes
MCode Programming and Software Reference
Input Functions (Points 7 & 8 — Clock Inputs and Point 13 — Capture)
Function
Description
Parameter
(S7, S8)
Active
Step/Direction
Sets IO 7 and 8 to receive step and
direction inputs from an external source.
The motion will occur based on the input
frequency seen at IO 7 in the direction
relative to the logic state of IO 8. The
step rate will be based upon the ratio set
by clock ratio (cr)
33
0/1
Quadrature
Sets IO 7 and 8 to receive channel a
and channel b quadrature inputs from an
external source such as an encoder. The
motion will follow the quadrature input.
34
0/1
Up/Down
Sets IO 7 and 8 to receive clock up/clock
down inputs from an external source.
The motion will occur based upon the
input clock frequency in the direction
relative to the input being clocked. The
step rate will be based upon the ratio set
by clock ratio (CR)
35
0/1
Function
Description
Parameter
(S13)
Active
High Speed
Capture
The capture input is a momentary high
speed input that operates with the trip
capture (TC) variable to run a subroutine
upon the trip. It feature variable input
filtering ranging from 50 ns to 12.9 Μs
60
0/1
Revision R062812
Table 7.6
7-8
Clock and high speed input functions
MCode Programming and Software Reference
7.2.4
7 Programming and Application Notes
Digital output functions
The outputs may be configured as general purpose or set to dedicated
functions, fault or moving. These outputs will sink up to 600 mA (one
channel of two banks) and may be connected to an external VDC
source.
The outputs are set using the “S” command (see Section 5 of this document for precise details on this command). The command is entered
into the terminal or program file as:
S<IO point>=<IO Type>,<Active State><Sink/Source>.
Examples
S9=17,1,0 ‘set IO point 9 to be a moving output, active
‘high, sinking
S3=18,0,0 ‘set IO point 3 to be a fault output, active
‘low, sinking
Output Functions
Revision R062812
Output functions may be programmed to be a general purpose user
output with the following functions.
Function
Description
Parameter
(S1-S4, S9-S12)
Active
Sink/
Source
General Purpose
User
A general purpose output can be
set in a program or in immediate
mode to trigger external events.
When used as a group they can
be a BCD output.
16
0/1
0/1
Moving
Will be in the active state when the
motor is moving.
17
0/1
0/1
Fault
Will be in the Active State when a
error occurs. .
18
0/1
0/1
Stall
Will be in the active state when a
stall is detected. Encoder required,
stall detect mode (SM) must be
enabled.
19
0/1
0/1
Velocity Changing
Will be in the active state
when the velocity is changing.
Example: during acceleration and
deceleration.
20
0/1
0/1
*Locked Rotor
Will be in an active state when the
rotor is locked on MDrive Hybrid
products
21
0/1
0/1
Moving to
Position
Will be active when the motor is
indexing to a commanded position.
22
0/1
0/1
*Hybrid Active
Will be active when the Hybrid
control circuitry is engaged.
23
0/1
0/1
*Make Up Active
Will be active when the Hybrid is
correcting lead/lag conditions.
24
0/1
0/1
*Only applies to Hybrid products.
Table 7.7
Digital output functions
7-9
7 Programming and Application Notes
MCode Programming and Software Reference
Output Functions (Points 7 & 8 — Clock
Outputs and Point 13 — Trip)
Function
Description
Parameter
(S7, S8)
Active
Step/Direction
Step clock pulses will be output from point 7,
direction from point 8. The step clock output
rate will be based upon the pulse width set
by clock width (CW). The logic state of the
direction output will be with respect to the
direction of the motor.
49
0/1
Quadrature
Will output Quadrature signals.
50
0/1
Up/Down
Will output clock up/clock down signals. The
step clock output rate will be based upon
the pulse width set by clock width (CW).
The active output will be based on the motor
direction.
51
0/1
Function
Description
Parameter
(S13)
Active
High Speed Trip
The trip output will activate on position trips
(TP) only. The output will pulse out at the trip
point. The pulse width will be determined by
clock width (CW)
61
0/1
Table 7.8
7.2.5
Clock and high speed output functions
Programmable I/O usage examples
The code examples below illustrate possible interface examples for
using the digital I/O.
Reference the hardware manual of your device for connection and wiring information
Input Interface Example - Switch Input
(Sinking Input)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
The following example shows a switch connected between an I/O point
and power ground.
Code Sample
For the code sample, this switch will be set up as a G0 sinking input,
active when low. When pressed, the switch will launch the program
beginning at address 1 in device memory:
***Setup Variables***
Sx=4,0,0 ‘set IO point x to be a G0 input, active when
‘LOW, sinking
Revision R062812
****Program***
PG1
MR 20000 ‘Move +20000 steps relative to current
position
H
‘Hold program execution until motion completes
MR -20000 ‘Move -20000 steps
H
‘Hold program execution until motion completes
E
PG
‘End program, exit program mode
7-10
MCode Programming and Software Reference
Input interface example - switch input example (sourcing input)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
7 Programming and Application Notes
The following circuit example shows a switch connected between an
I/O point and a voltage supply which will source the input to perform a
function.
Code Sample
For the code sample, the switch will be set up as a soft stop sourcing
input, active when high. When pressed, the switches will stop the motor.
S1=5,1,1
‘set IO point 1 to be a Soft Stop input, active
‘when HIGH, sourcing
SL 200000 ‘slew the motor at 200000 μsteps/sec
When the switch is depressed the motor will decelerate to a stop.
Output interface example (sinking output)
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
The following circuit example shows a load connected to an I/O point
that will be configured as a sinking output.
For the code sample, the load will ben LED. T motor is a tonfigured
such that the LED will be lit while the motor is at constant velocity. Set
input 1 up to be a soft stop input using a switch in a sinking configuration this will soft stop the motor.
S1=5,0,0
‘set IO point 1 to be a Soft Stop input, active
‘when LOW, sinking.
S1=20,0,0 ‘set IO point 2 to be a Velocity Changing
‘output, active when LOW
SL 2000000 ‘slew the motor at 200000 μsteps/sec
Revision R062812
While the motor is accelerating the LED will be dark, but will light up
when the motor reaches a constant velocity. When the Soft Stop switch
is depressed the motor will begin to decelerate, the LED will go dark
again while velocity is changing.
7-11
7 Programming and Application Notes
Output interface example (sourcing output)
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce (Plus2 expanded features)
MCode Programming and Software Reference
The following circuit example shows a load connected to an I/O point
that will be configured as a sourcing output.
Code Sample
For the code sample, the load will be a relay. The output will be configured to be a general purpose user output that will be set active when a
range of motion completes.
******Setup Variables******
S1=16,1,1 ‘set IO 1 = user output, active HIGH, sourcing.
******Program******
PG 100
‘Enter program at address 100
MR 2000000 ‘Move x in the positive direction
H
‘Hold execution until motion completes
MR -1000000
‘Move x distance negative direction
H
‘Hold execution until motion completes
O1=1
‘Set output 1 HIGH
Enter EX 100 to execute the program, the motion will occur and the
output will set high.
Reading inputs as a group example
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
The inputs may read as a group using the IL. IH and IN keywords. This
will display as a decimal between 0 to 15 representing the 4 bit binary
number (IL, IH) or as a decimal between 0 and 255 representing the 8
bit binary number on the devices with expanded I/O. The IN keyword will
function on the devices with standard I/O but will only read inputs 1 - 4.
Inputs will be configured as user inputs (S<point>=0).
Standard I/O
PR IN
PR IN
‘Reads Inputs 4(MSB) through 1(LSB)
‘Reads Inputs 4(MSB) through 1(LSB)
Expanded I/O
Revision R062812
PR IL
PR IH:
PR IN:
7-12
‘Reads Inputs 4(MSB) through 1(LSB)
‘Reads Inputs 12(MSB) through 9(LSB)
‘Reads Inputs 12(MSB) - 9 amd 4 - 1(LSB)
MCode Programming and Software Reference
Interfacing outputs as a group example
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
7 Programming and Application Notes
Outputs may be written to as a group using the OL, OH and OT keywords. This will set the outputs as a binary number representing the
decimal between 0 to 15 representing the 4 bit binary number (OL,
OH) or as an 8 bit binary number representing the decimal 0 to 255 on
texpanded I/O devices. The OT keyword will function on tstandard I/O
devices, but will only set outputs 1 - 4. Outputs will be configured as
user outputs (S<point>=16).
Standard I/O
OL=3
I/O to 0011
OT=13
I/O to 1101
‘set the binary state of the standard
‘set the binary state of the standard
Expanded I/O
OL=5
‘set the binary state of the standard
I/O to 0101
OH=9
‘set the binary state of the expanded
I/O to 1001
OT=223
‘set the binary state of the combined I/O to
1101 1111
7.2.6
Dedicated digital I/O usage
Compatible with Motion Control products:
MDrive (Plus2 expanded features)
MForce (Plus2 expanded features)
Step/Direction
These dedicated I/O lines are used to receive clock inputs from an
external device or provide clock outputs to an external device such as a
counter or a second device in a system. The clock I/O can be configured
as one of three clock types using the S7 and S8 variable:
1)
Step/Direction
2)
Quadrature
3)
Up/Down
The Step/Direction function would typically be used to receive step and
direction instructions from a second system device or secondary controller. When configured as outputs the device can provide step and direction control to another system drive for electronic gearing applications.
Step Clock
Input: S<7>=33, <active state>
Output: S<7>=49,<active state>
Direction
Input: S<8>=33, <active state>
Output: S<8>=49,<active state>
Revision R062812
Figure 7.1 Step/direction I/O type & configuration
7-13
7 Programming and Application Notes
Quadrature
MCode Programming and Software Reference
The quadrature clock function would typically be used for following
applications where the device would either be a master or slave in an
application that would require two motors to move the same distance
and speed.
Channel A
Channel B
Input: S<7>=34, <active state>
Output: S<7>=50,<active state>
Input: S<8>=34, <active state>
Output: S<8>=50,<active state>
Figure 7.2 Quadrature I/O configuration
CW/CCW
The cw/ccw clock would typically be used in a dual-clock direction control application, or to increment/decrement an external counter.
CW
Input: S<7>=35, <active state>
Output: S<7>=51,<active state>
CCW
Input: S<8>=35, <active state>
Output: S<8>=51,<active state>
Revision R062812
Figure 7.3 CW/CCW I/O configuration
7-14
MCode Programming and Software Reference
7.2.7
7 Programming and Application Notes
Analog input usage
Compatible with Motion Control products:
MDrive
MDrive (Plus2 expanded features)
MDrive Hybrid
MForce
MForce (Plus2 expanded features)
The analog input is configured from the factory as a 0 to 5V, 10 bit
resolution input (S5=9). This offers the user the ability to receive input
from temperature, pressure, or other forms of sensors, and then control
events based upon the input.
The value of this input will be read using the I5 instruction, which has a
range of 0 to 1023, where 0 = 0 volts and 1024 = 5.0 volts. The anlog
input may also be configured for a 4 to 20 mA or 0 to 20 mA Analog
Input (S5 = 10). If used as a 4 to 20mA input the range is 0 to 800 units.
Sample Usage
‘***********Main Program**************
S5=9,0
PG
LB
CL
CL
BR
100
A1
A2, I5<500
A3, I5>524
A1
‘set analog input to read variable
‘voltage (0 to +5VDC)
‘start prog. address 100
‘label program A1
‘Call Sub A2, If I5 is less than 500
‘Call Sub A3, If I5 is greater than 524
‘loop to A1
‘***********Subroutines**************
‘label subroutine A2
‘Move Absolute 2000 steps
‘Hold program execution until motion ceases
‘return from subroutine
LB A3
MA -2000
H
RT
E
PG
‘label subroutine A3
‘Move Absolute -2000 steps
‘Hold program execution until motion ceases
‘return from subroutine
‘End
‘Exit program
Revision R062812
LB A2
MA 2000
H
RT
7-15
7 Programming and Application Notes
MCode Programming and Software Reference
7.3
Factors impacting motion commands
7.3.1
Motor steps
All MCode examples assume 200 step motors. They rotate at 1.8° per
clock pulse. 200 steps would equal 1 revolution. MCode devices such
as the MForce line may be used with different step resolution motors,
such as 0.9° motors.
7.3.2
Microsteps: (MS)
Microsteps divide the 200 motor steps into smaller steps to improve
smoothness and resolution of the MCode compatible device. Using
the default setting of 256 for MS, the 200 motor steps are increased to
51200 microsteps. One motor revolution requires 51200 microsteps with
the ms set at 256. If you were to set the ms to 128, one revolution of the
motor would now require 25600 microsteps.
7.3.3
Move Command
The move absolute (MA) and the move relative (MR) commands are
programmed in microsteps or if the encoder is enabled, encoder
counts. If the ms was set at 256 and you were to program a move of
51200 microsteps, the motor would turn one full revolution. If the ms
was set to 128, one full revolution of the motor would be 25600 microsteps (128 x 200). If you programmed a move of 51200, the motor
would turn 2 full revolutions.
7.3.4
Closed loop control with an encoder
If the encoder is enabled the move commands use different values. The
encoder has 512 lines and yields 2048 counts or counts per revolution. Therefore, the MR and MA command values are programmed in
encoder counts. One full revolution would be programmed as mr or ma
2048.
When the encoder is enabled, the MS value is defaulted to 256. It cannot be changed.
Revision R062812
Knowing these factors you can program a multitude of different movements, speeds, and time intervals.
7-16
MCode Programming and Software Reference
7.3.5
7 Programming and Application Notes
Linear movement
You have a rack and pinion or a ball screw to move a linear axis. The
rack and pinion or ball screw moves the linear axis 0.1 inches for each
revolution. You need to move 7.5 inches.
7.5 inches divided by 0.1 inches = 75 motor revolutions.
Assuming an MS of 256 (51200 Microsteps) is programmed, 51200
Microsteps x 75 revolutions requires a move of 3840000 microsteps.
Knowing the values of the variables as well as the required move, you
can calculate the actual time it takes to move the axis the required distance. This is done with a trapezoidal profile as shown below.
VM=768000
VI=1000
t1= .767
294528
Microsteps
t2= 4.233
3250944
Microsteps
t3= .767
294528
Microsteps
Ttotal = 5.767
Figure 7.4 Trapezoidal move profile
Calculating axis speed (velocity)
There are several steps required to determine the actual axis speed.
They are all based on the Trapezoidal Profile above.
Known Values and Parameters:
VM..........................768000 Steps/Sec.
VI................................1000 Steps/Sec.
A.........................1000000 Steps/Sec2.
D ........................1000000 Steps/Sec2.
MA/MR .................3840000 Microsteps
Determine the Acceleration (A) and Deceleration (D) times (t1 and t3).
Since the Deceleration (D) value is also 1000000 Steps/Sec. the Deceleration time (t3) will be the same as the Acceleration time (t1).
768000 - 1000
Revision R062812
VM - VI
(t1 and t3)=
A
OR
= 0.767 Seconds
1000000
7-17
7 Programming and Application Notes
MCode Programming and Software Reference
Determine the distance (Steps) traveled in t1 or t3.
VM + VI
Distance=
768000 + 1000
x t1
2
OR
x 0.767
2
= 294911 steps
Determine the t2 time.
The t2 time is calculated by dividing the remainder of MA/MR by VM.
The remainder of MA/MR = MA/MR - (t1 steps + t3 steps) or 3840000
- 589056 = 3250944.
3250944
t2 =
768000
= 4.233 Seconds
Determine the total time. (t1 + t2 + t3) or (0.767 + 4.233 + 0.767) =
5.767 Seconds
The linear axis took 5.767 seconds to move 7.5 inches or an average
speed of 78 inches/minute.
Note that the average speed includes the Acceleration and Deceleration. The maximum axis speed attained is approximately 90 inches/
minute.
768000
x 0.1 x 60 = 90 IPM
Revision R062812
51200
7-18
MCode Programming and Software Reference
7.3.6
7 Programming and Application Notes
Calculating rotary movement
Assume the MS is set to 256. You are using the motor to drive a shaft
with a timing belt and pulley arrangement. As shown below, the pulley is
1” in diameter and the shaft pulley is 2.5” in diameter. You must turn the
shaft 270°.

The shaft will rotate 1 full revolution for every 2.5 revolutions of
the motor.

270° is 0.75 of a revolution.

0.75 x 2.5 = 1.875 motor revolutions to turn the shaft 270°.

If 51200 Microsteps is 1 motor revolution, then the device must
be programmed to move 96000 Microsteps (51200 x 1.875).
You may also do many of the calculations in reverse to calculate motor
moves to meet a required move of your device. A linear or rotational
move as well as speed may be translated into an MCode command.
270°
2.5"
1.0"
Motor pulley
1.875 Revolutions
Shaft pulley
0.75 Revolution
Rotary drive example 1
110°
1.5"
4"
Motor pulley
Revision R062812
Rotary table
Rotary drive example 2
Figure 7.5 Rotary examples
7-19
7 Programming and Application Notes
MCode Programming and Software Reference
In the example above, the belt driven rotary table must be turned 110°
at 3 RPM. How should the device be set up?
Bear in mind that all the numbers are approximate due to rounding.
Mechanical ratio between the motor and the rotary table is 2.666:1. That
is, the motor must rotate 2.666 revolutions for the table to rotate 1 revolution and the table will rotate 2.666 times slower than the motor.
In order to move the table 110° the motor must move 293.3°.
110 x 2.66 = 293.3º
If 51200 steps = 1 revolution then 1° = 142.222 steps.
51200
360
= 142.222 steps
The MCode device must be programmed to move 41713 steps to
rotate 293.3°.
142.222 steps x 293.3º = 41713 steps
In order to rotate the table at 3 RPM the motor must turn at 8 RPM.
3 RPM x 2.666 = 8 RPM
If you were to set VM at 51200 and MS set at 256 the motor will rotate 1
full revolution (51200 steps) in 1 second or 1 RPS. In order to rotate at
8 RPM, the motor must rotate at 0.13333 RPS.
8
60
= 0.133333 RPS
In order to rotate at 0.13333 RPS the VM must be set at 6827 steps/
sec.
51200 x 0.133333 = 6827
VM = 6827
Revision R062812
Note: These numbers will vary slightly depending on Acceleration and
Deceleration rates.
7-20
MCode Programming and Software Reference
7.3.7
7 Programming and Application Notes
Programming with the optional encoder enabled
An optional 512 line magnetic encoder is available. When the Encoder
is enabled (EE=1) the programming also changes. All motion must now
be programmed by the encoder counts. The Encoder operates in the
“Quadrature” format. That is, there are four Encoder counts for each Encoder line or 2048 counts per revolution (512 × 4 = 2048). (See Figure
below.) If you were to program motion using the MR (Move Relative) or
MA (Move Absolute) commands the motor would rotate a distance equal
to the encoder counts.
1 Encoder
Line
90°
Electrical
3
1
Channel A
2
4
Channel B
(4 Encoder Pulses per Encoder Line)
Figure 7.6 Encoder waveform
Example:
A programmed move of 7168 counts would result in the motor rotating
3.5 revolutions at a velocity controlled by VM.
7168 ÷ 2048 = 3.5 revolutions
If you were to program motion using the SL (Slew) command the motor
would rotate at a “counts per second” rate based on the programmed
value.
Example:
An SL (Slew) rate of 7168 counts was programed. The motor will rotate
at 7168 counts/sec., 3.5 RPS, or 210 RPM.
7168 ÷ 2048 = 3.5 RPS × 60 = 210 RPM
Revision R062812
When the Encoder is enabled, the parameters are also changed to be
compatible with the 2048 counts.
7-21
7 Programming and Application Notes
MCode Programming and Software Reference
The Encoder Enabled defaults are:
VM ............................................ 30720 Counts/Sec.
VI .................................................... 40 Counts/Sec.
A ................................................ 40000 Counts/Sec
D ............................................... 40000 Counts/Sec.
MS ........................ 256 (default for encoder mode.)
To enable the encoder the program syntax is <EE=n> where n is a zero
(0) or a one (1). The default is zero (0) which is encoder disabled. To
enable the encoder, program EE=1.
Any motion will now be programmed in encoder counts. You can calculate the distance or velocity you need in a similar manner as done
previously only with different factors.
Note: The microstep select is defaulted and locked at 256 in the encoder mode to ensure stable, high resolution.
Several Variables work in conjunction with Encoder Enable (EE). They
are:
DB ...........................................Encoder Deadband
SF.................................... The Stall Factor Variable
SM .................................. The Stall Detection Mode
ST.............................................................Stall Flag
PM ........................................ Position Maintenance
EE ............................................... Encoder Enabled
When the encoder is enabled, all motion is “closed loop”. That is, motion
steps are delivered from the MCode device to the motor which turns the
encoder. The encoder sends counts back to the drive to complete the
motion. If you programmed a move of 2048 counts, the device would
output an appropriate number of microsteps provided the stall factor
(SF) value or other fault is not encountered. If no faults were encountered, the device would output the full amount of microsteps. Depending
on which variables were set, the driver would then wait until the position
(plus or minus the encoder deadband) was read and confirmed.
Revision R062812
DB - Encoder Deadband
7-22
The Encoder Deadband is a Variable that is set in Encoder Counts.
Motion will be deemed complete when the Encoder Counts are within ±
the Deadband variable. With DB=5 the motion of 2048 counts would be
complete between 2043 and 2053 counts.
MCode Programming and Software Reference
SF - Stall Factor
7 Programming and Application Notes
The Stall Factor is a Variable which is entered in Encoder Counts. The
Stall Factor is active only in the EE=1 mode. The Stall Factor might be
compared to the “following error” or “lag error” of a servo drive. The Stall
Factor is triggered by the number of steps output from the device to the
motor as compared to the number of counts returned by the encoder.
The comparison should always be within the value of the Stall Factor,
otherwise a fault will occur and the Stall Flag (ST) will be set. If the Stall
Detection Mode is active (SM=0), the motion will be stopped.
Example:
A Stall Factor of 30 counts (SF=30) is programmed. A motion command
of 2048 counts is programmed. The device reaches a mechanical bind
at 2000 counts. The device will keep outputting steps equivalent to 2030
counts (present position plus the SF value) and then the Stall Flag (ST)
will be set. The motor will be stopped if the Stall Detection Mode (SM=0)
is active.
SM - Stall Detection Mode
ST - Stall Flag
PM - Position Maintenance
The Stall Detection Mode can be programmed to stop the device
(SM=0) or to allow the device to continue (SM=1) when the Stall Factor
(SF) is reached. Whether SM is active or not, the Stall Flag will always
be set when the SF is encountered.
The Stall Flag will be set any time the SF is reached regardless of the
state of the Stall Detection Mode (SM). If the Stall Flag is set, the user
must reset it to zero (0).
Position maintenance (PM) is active only after the motion has completed. Position maintenance is used to maintain position when there might
be an external force on the drive. If position maintenance is enabled
(PM=1) and the stall detection mode is enabled (SM=0), the motor will
be driven back to its final position if it was forced out of position provided
the stall factor (SF) was not reached.
If position maintenance is enabled (PM=1) and the stall detection mode
is disabled (SM=1), the motor will be driven back to its final position if it
was forced out of position regardless of whether the stall factor (SF) was
reached or not.
There are three other variables, although not directly conned to EE, that
do affect the overall operation when in encoder mode, they are:
HC.............................................. Motor Hold Current
HT ........................... Motor Hold Current Delay Time
MT....................................Motor Settling Delay Time
Revision R062812
HC.........................................................Hold Current
When motion is complete, the device will switch from motor run current (RC) to motor hold current (HC). The hold current is set at a lower
percentage than the run current (rc). However, the hold current must be
sufficient to overcome an outside force such as driving a vertical slide
which maintains a load on the motor at all times. Actual hold current
7-23
7 Programming and Application Notes
MCode Programming and Software Reference
values will vary depending on the application and the load on the motor
when it is at rest.
HT - Motor Hold Current Delay Time
The motor hold current delay time (HT) is a variable that delays the
change from run current (RC) to hold current (HC) at the end of a move.
The end of the move is triggered by the device when it has completed
outputting the correct number of steps. Depending on the application,
including velocity, deceleration, load and inertia, the device may lag behind a few counts. The ht will allow the device to finish its move before
applying the lower HC.
MT - Motor Settling Delay Time
A stepping motor may ring or oscillate in minuscule amounts at the
completion of a move until it satisfies the target position. The amount of
this “ringing” is dependent on the application including velocity, deceleration, inertia, friction and load. The motor settling delay time (MT)
allows the motor to stop “ringing” before checking the position count. If
the device tried to check the position count during this ringing, it would
assume a position error and try to correct an already moving motor and
possibly cause ringing of a larger magnitude and longevity. Typically,
the MT is set between 50 and 100 milliseconds. It is recommended that
there is always a Motor Settling Time programmed any time you are in
EE=1 mode.
Revision R062812
Note: If MT has no value, the motor may hunt and never satisfy the position check.
7-24
MCode Programming and Software Reference
7.4
7 Programming and Application Notes
MForce PWM configuration
!
CAUTION
This variable is only applicable to the mforce product line and is used to tune
the PWM Settiings to optimize the current control of the MForce driver. It
should not be used unless erratic motion or positional accuracy problems are
being experienced.
Note that there are other factors that could contribute to these problems. Ensure that all wiring conforms to the guidelines in the mforce hardware manual.
Be aware that this parameter, when used with the checksum will write to the
boot sector of memory. This sector only allows eight write cycles. Ensure that
the settings you choose are optimal prior to storing the parameter to the boot.
Read this section closely before making changes to the PWM settings. Please
contact application support for questions concerning the use of this command.
7.4.1
Description:
This variable defines the parameter settings for the PWM and should
not be used unless motion problems such as smoothness and positional
accuracy are experienced.
The PW variable consists of four components: <mask>, <period>,
<sfrq> and either <checksum>, if writing, or <boot_writes_remaining> if
reading using the PR keyword.
7.4.2
PWM Mask <mask> Parameter
The PWM mask signal prevents the premature end of the forward period
caused by switching transients when the motor phase current is at low
levels. Adjusting this value can impact the zero-crossing performance of
the motor. If experiencing the “tick” which is inherit in stepper motor systems, this may be minimized or eliminated by adjusting this value. The
range of this value is 0 to 255d and will be entered as a decimal value.
The Mask will act as a filter on the PWM signal to allow time for any
ringing in the output circuitry to settle.
This range represents a 8-bit Hex value that specifies the Bridge
Reverse Measure Time (REVTM) and the Minimum Bridge Forward
On Time (FORTM) ranging from 600 nS to 3.4 μS each (see table and
diagram below). Typically these values would be balanced. The table
below shows the decimal value for each time.
Note that these are typical values and the currents may be unbalanced
to fine tune the motor performance.
Revision R062812
The default value for this parameter is 204 (0xCC), which represents a
Reverse Measure Time and Minimum Forward On Time of 2.5 μS.
7-25
7 Programming and Application Notes
MCode Programming and Software Reference
Hex
0x0
0x1
0x2
0x3
Time
600 ns
700 ns
800 ns
900 ns
Table 7.8
Hex
0x4
0x5
0x6
0x7
Time
1.0 μs
1.1 μs
1.2 μs
1.4 μs
Time
1.6 μs
1.8 μs
2.0 μs
2.2 μs
Hex
0xC
0xD
0xE
0xF
Time
2.5 μs
2.8 μs
3.1 μs
3.4 μs
PWM Mask Settings
Reverse Measure Time
1
Hex
0x8
0x9
0xA
0xB
1
0
1
Min. Forward On Time
1
0xD (2.8 μS)
1
0
1
0xDD
0xD (2.8 μS)
Convert to Decimal
PWM Mask Value = 221
Figure 7.7 PWM mask bits
Mask Mask REVTM FORTM
(hex) (dec)
0x00
0
600 ns 600 ns
0x11
17 700 ns 700 ns
0x22
34 800 ns 800 ns
0x33
51 900 ns 900 ns
0x44
68
1.0 μs 1.0 μs
0x55
85
1.1 μs 1.1 μs
0x66 102 1.2 μs 1.2 μs
0x77 119 1.4 μs 1.4 μs
Table 7.9
7.4.3
Mask Mask REVTM FORTM
(hex) (dec)
0x88 135 1.6 μs 1.6 μs
0x99 153 1.8 μs 1.8 μs
0xAA 170 2.0 μs 2.0 μs
0xBB 187 2.2 μs 2.2 μs
0xCC 204 2.5 μs 2.5 μs
0xDD 221 2.8 μs 2.8 μs
0xEE 238 3.1 μs 3.1 μs
0xFF 255 3.4 μs 3.4 μs
Typical PWM Mask Settings
Maximum PWM duty cycle (%) <period> parameter
This parameter sets the maximum duty cycle as a percentage of the
bridge PWM oscillator period. The range for this parameter is 0 to 95%.
Entries above 95% will generate an out of range error (Error 21) and will
not allow the setting to be written to the boot.
Revision R062812
The default value for this parameter is 95%.
7-26
MCode Programming and Software Reference
7.4.4
7 Programming and Application Notes
PWM frequency <sfreq> parameter
The PWM Frequency Parameter sets the initial and maximum frequencies for the PWM. As with the MASK parameter, the PWM Frequency is
a two part 8-bit hex number which is entered as a decimal value ranging
from 0 to 255.
The default for this 170 (0xAA) with an initial PWM Frequency of 20 kHz
and a Maximum of 60 kHz.
Hex
0x0
0x1
0x2
0x3
Freq.
40
42
44
46
Hex
0x4
0x5
0x6
0x7
Freq
48
50
52
54
Hex
0x8
0x9
0xA
0xB
Freq
56
58
60
62
Hex
0xC
0xD
0xE
0xF
Freq
64
66
68
70
Hex
0x8
0x9
0xA
0xB
Freq
18
19
20
21
Hex
0xC
0xD
0xE
0xF
Freq
22
23
24
25
Table 7.10 Maximum PWM frequency
Hex
0x0
0x1
0x2
0x3
Freq.
10
11
12
13
Hex
0x4
0x5
0x6
0x7
Freq
14
15
16
17
Table 7.11 Initial PWM frequency
PWM Max. Frequency
0
1
0
1
PWM Initial Frequency
1
0x5 (50 kHz)
1
1
0
0x5E
0xE (24 kHz)
Convert to Decimal
PWM SFREQ = 94
PWM Frequency Range 24 to 50 kHz
Revision R062812
Figure 7.8 PWM frequency range
7-27
7 Programming and Application Notes
7.4.5
MCode Programming and Software Reference
PWM checksum <chksum> parameter (boot write only)
!
CAUTION
This parameter should be left blank for testing parameters. Only insert a checksum
if you have verified that these parameters cause the motor to perform as desired
as the presence of the checksum WILL write the PWM settings to the boot, Limited
Writes (8) are available.
The PWM checksum parameter is only used on the write cycle to write
the PWM parameters to the boot. To write the PWM parameters to an
Mforce a checksum must be sent along with the parameters.
PW = mask, period, frequency, checksum
To compute the checksum use the following steps:
1.
Add the decimal values for mask, period, and frequency. Total =
mask + period + frequency
2.
Use A, B, or C to calculate checksum
A. If the total is less than or equal to 256:
(Total <= 256) checksum = 256 - Total
B. If the total is greater than 256 but less than or equal to 512:
(256 < Total <= 512) checksum = 512 - Total
C. If the total is greater than 512, then:
(Total > 512)checksum = 768 - Total
Examples
Add 102 + 90 + 10 = 202. The total is less than 256 so use A. to calculate checksum.
Checksum = 256 - 202
Checksum = 54
PW = 102,90,10,54
Add 238 + 95 + 170 = 503. The total is greater than 256 but less than or
equal to 512 so use B. to calculate checksum.
Checksum = 512 - 503
Checksum = 9
PW = 238,95,170,9
Add 255 + 90 + 170 = 515. The total is greater than 512 so use C. to
calculate checksum.
Revision R062812
Checksum = 768 - 515
Checksum = 253
PW = 255,90,170,253
7-28
MCode Programming and Software Reference
7.4.6
7 Programming and Application Notes
Boot writes remaining <boot_writes_remaining> parameter (read only)
This parameter will be the fourth parameter shown during a read of the
PWM settings (PR PW).
The range is from 8 to 0 and represents the number of times remaining
that the PWM settings can be written to the boot of the drive.
7.4.7
Example PWM settings by motor specifications
The following settings are based upon IMS settings per motor specifications and should serve as a baseline to work from with regard to the
manufacturer specifications of the motor being utilized. Note that these
are example settings ONLY!
Frame Stack
Size
Size
Phase
Current
(ARMS)
Phase
Resistance
(Ω)
Phase
Inductance MASK
<mask>
(mH)
Duty
Cycle
<period>
Frequency Checksum
<sfreq>
<chksum>
14
Single
0.75
4.30
4
102
90
170
250
Single
1.5
1.30
2.1
136
90
170
116
Double
1.5
2.10
5.0
136
90
170
116
Triple
1.5
2.00
3.85
136
90
170
116
Single
2.4
0.95
2.4
136
90
170
116
Double
2.4
1.20
4.0
136
90
170
116
Triple
2.4
1.50
5.4
136
90
170
116
Single
6.3
0.25
1.6
168
95
170
79
Double
6.3
0.35
3.3
220
95
170
27
Triple
6.3
0.50
6.6
253
95
170
250
—
—
—
204
95
170
—
17
23
34
MForce Default
Table 7.9 Example PWM settings
Usage Example
PW=102,90,150
‘set pwm, DO NOT WRITE TO BOOT!
PW=136,90,170,116 ‘set pwm settings, write to boot
‘read PWM
‘last integer notes 7 boot
‘writes remaining
Revision R062812
PR PW
Response = 136,90,170,7
7-29
7 Programming and Application Notes
MCode Programming and Software Reference
Revision R062812
This page intentionally left blank
7-30
MCode Programming and Software Reference
8
8 Sample Programs
Sample programs
This section is made up of several example programs designed to aid
the user in discovering the MCode programming language.
8.1
Move on an input
‘Last modified: 01/26/2006
‘Purpose: Demonstrate move on input.
‘System configuration
S1=0,0
‘set IO1 to gen. purpose input, active LOW,
‘sinking
Ms=256
‘set μstep resolution to 256 μsteps/step
Vi=200000 ‘set initial velocity to 200000 steps/sec
Vm=2500000 ‘set max velocity to 2500000 steps/sec
A=1000000 ‘set acceleration to 1000000 steps/sec2
D=A
‘set deceleration equal to acceleration
Hc=2
‘set motor holding current to 2%
Rc=75
‘set motor run current to 75%
P=0
‘set position counter to 0
‘Main program
PG 1
‘enter program mode at address 1
LB Ga
‘label program Ga
P=0
‘initialize position counter
LB G1
‘label program G1
CL Kb,I1=1
‘call subroutine Kb on input HIGH state
H 10
‘hold program execution 10 msec
BR G1
‘loop to G1
‘Subroutine from trigger event
LB Kb
‘declare subroutine Kb
MA 51200
‘move to absolute motor position
H
‘suspend program execution until
‘completes
MA 0
‘move to absolute motor position
H
‘suspend program execution until
‘completes
RT
‘return from subroutine
0
motion
‘designate end of program
‘exit to immediate mode
Revision R062812
E
PG
51200
motion
8-1
8 Sample Programs
8.2
MCode Programming and Software Reference
Change velocity during a move
This program will demonstrate ability to change speed during move.
The device does not have abiltity to change speed during point to point
move, so we use the slew command with position trips. End position
trip, decel and slew speed determine actual ending position. Program
is written to print ending position to serial port 100 times for averaging,
expected end position = 102400.
‘System configuration
Ms=256
‘set μstep resolution to 256 μsteps/step
Hc=20
Rc=100
‘set motor holding current to 20%
‘set motor run current to 75%
‘Main program
PG 1
LB Ga
‘Program Label Ga sets up local variables and
‘register values
Vi=20000
Vm=500000
A=500000
D=800000000
R1=0
R2=0
LB Gx
‘Program label Gx sets up position
‘trips and math functions
P=0
Tp=51200,Kb
‘set position trip at P=51200
Te=2
SL 101200
H
H 250
R1=R1+1
‘increment R1
R2=R2+P
‘add position to r2 to set up position
calculation
BR Gx,R1<100
‘loop to Gx if R1 indicates less than
‘100 moves
R2=R2/100
‘after 100 moves have completed, r2 is
‘divided by 100
PR “Average end pos = “,R2
‘to obtain and print
‘final Pos.
E
‘Subroutines
LB Kb
SL 202400
Tp=102290,Kc
Te=2
RT
Revision R062812
LB Kc
in Kb
SL 0
H
RT
PG
8-2
‘Subroutine called by position trip in
‘Gx which doubles
‘the motor speed
‘Subroutine executed by position trip
MCode Programming and Software Reference
8.3
8 Sample Programs
Binary mask
This program will demonstrate ability to execute various subroutines
depending on the binary value of inputs 1-3 while masking all i/o above
input 3.
‘System configuration
S1=0,1
‘setup IO points 1-4, 9-11 as General purpose
user
S2=0,1
S3=0,1
S4=0,1
S9=0,1
S10=0,1
S11=0,1
S12=16,0 ‘set up IO point 12 as a gen. purp. output
Ms=256
‘global system variable declarations
Vi=20000
Vm=1000000
A=500000
D=A
Hc=20
Rc=75
‘Main program
PG 1
LB Ga
P=0
LB G1
R1=In
‘capture input combined value to register 1
R1=R1 & 7
‘bits 00000111=7
CL k0,R1 = 0
‘Subroutine calls based on the decimal
‘value of IO
CL k1,R1 = 1
‘points 1-3
CL k2,R1 = 2
CL k3,R1 = 3
CL k4,R1 = 4
CL k5,R1 = 5
CL k6,R1 = 6
CL k7,R1 = 7
H 10
BR G1
E
Revision R062812
‘Subroutines
LB k0
PR “Logic 000”
MR 0*51200
H
H 200
RT
‘Declare sub K0 executed if R1=0
LB k1
PR “Logic 001”
MR 1*51200
H
H 200
RT
‘Declare sub K1 executed if R1=1
LB k2
PR “logic 010”
MR 2*51200
H
H 200
‘Declare sub K2 executed if R1=2
8-3
8 Sample Programs
MCode Programming and Software Reference
RT
LB k3
PR “Logic 011”
MR 3*51200
H
H 200
RT
‘Declare sub K3 executed if R1=3
LB k4
PR “Logic 100”
MR 4*51200
H
H 200
RT
‘Declare sub K4 executed if R1=4
LB k5
PR “Logic 101”
MR 5*51200
H
H 200
RT
‘Declare sub K5 executed if R1=5
LB k6
PR “Logic 110”
MR 6*51200
H
H 200
RT
‘Declare sub K6 executed if R1=6
LB k7
PR “Logic 111”
MR 7*51200
H
H 200
RT
‘Declare sub K7 executed if R1=7
Revision R062812
E
PG
8-4
MCode Programming and Software Reference
8.4
8 Sample Programs
Closed Loop
This program illustrates closed loop control with an On Error (OE)
routine which will perform math functions on the counters to display the
position error.
‘System configuration
Ms=256
‘declare global system variables and flags
Hc=5
Rc=80
Ee=1
‘encoder enabled
A=60000
D=A
Vi=2048
Vm=30000
S1=0,0
Sf=15
‘encoder stall variables declared
Sm=0
Mt=50
VA Q1
‘user variable Q1 declared
‘Main program
PG 1
LB Ga
OE k1
P=0
LB Gb
‘Ga declares the error call and locally
‘sets the position
‘counter to 0 encoder counts
‘Gb performs ± motions and increments
‘Q1 after each
MR 51200 ‘until Q1 reaches 100
H
H 500
MR -51200
H
H 500
IC Q1
BR Gb,Q1<100
E
‘Subroutines
LB k1
‘Sub K1 calculates the position error
‘by dividing
R3=C1/25
‘actual motor steps moved by 25 and
‘subtracts
R1=R3 - C2
‘the number of encoder counts in C2 to
‘determine
PR “Counts error = “,R1 ‘the counts error
PR “Error = “,Er
Er=0
H 20
RT
Revision R062812
E
PG
8-5
8 Sample Programs
8.5
MCode Programming and Software Reference
User input into variables
This program demonstrates the ability to hold up program execution
while the user enters multiple variables. Uses registers R1-R3 and a
user declared flag for program control.
‘System configuration
Ms=256
‘Global variable declarations
Vi=10000
Vm=50000
A=10000
D=A
Hc=5
Rc=70
P=0
R1=0
‘Registers set to 0
R2=0
R3=0
VA X1=0
‘User flag X1 declared and set to 0
Revision R062812
‘Main program
PG 1
LB G1
‘Local var-flg settings
P=0
X1=0
LB G2
‘label for program hold loop
H 20
BR G1,X1=0 ‘command for pg hold loop
LB G3
X1=0
‘reset x1 to 0.
A=R1
‘set A to R1 value
D=A
Vm=R2
MR R3
H
H 500
BR G2
PG
8-6
MCode Programming and Software Reference
8.6
8 Sample Programs
Closed loop with homing
This program demonstrates the use of the home to home switch instruction (HM) in closed loop, also there is a move on input routine.
Ee=1
Vm=4096
Vi=Vm/50
A=20480
D=A
Hc=50
Rc=50
Mt=50
Sf=20
Sm=0
Db=5
S1=1,0
S2=0,0
S3=17,0
S4=19,0
‘Global variable and flag declarations
‘Home input
‘Move on input
‘Moving output
‘Fault output
D1=100
Revision R062812
‘Program
PG 1
LB G1
H 1000
PR “C1 “,C1
PR “C2 “,C2
Pm=1
PR “C1 “,C1
PR “C2 “,C2
H 5000
HM 1
H
P=0
LB G2
BR G2,I2=0
MR 7186
H
PR “p=”,P
BR G2
E
PG
8-7
8 Sample Programs
8.7
MCode Programming and Software Reference
Input trip
This program demonstrates the use input trips
‘System configuration
Ms=256
Hc=0
Rc=100
D=800000000
Vi=10000
Vm=50000
S1=0,0
S2=16,0
S3=16,0
S4=16,0
O2=1
O3=1
O4=1
‘Main program
PG 1
LB Ga
CL K1 ‘call to configure 1st input trip
SL 50000
LB Gb
H 10
BR Gb,Mv>0
R3=R2-R1
PR “Distance between inputs = “,R3
H 1000
PR “ “
BR Ga
E
‘Subroutines
LB K1
‘Config for 1st input trip
S1=0,0
Ti=1,K2
Te=1
RT
LB K2
R1=Pc
S1=0,1
Ti=1,K3
Te=1
RT
‘Config for 2nd input trip
LB K3
R2=Pc
SL 0
‘Sub for 2nd input trip
LB K4
BR K4,Vc=1
RT
Revision R062812
E
PG
8-8
MCode Programming and Software Reference
9
9 Error Codes
Error codes
A question mark <?> Displayed as a cursor indicates an error. To determine what the error is, type <pr er> in the terminal window. The device
will respond with an error number displayed in the terminal window. The
error number may then be referenced to this list.
0
9.1
I/O errors
6
An I/O is already set to this type. Applies to non-General Purpose I/O.
8
Tried to set an I/O to an incorrect I/O type.
9
Tried to write to I/O set as Input or is “TYPED”.
10
Illegal I/O number.
11
Incorrect CLOCK type.
12
Illegal Trip / Capture
Data errors
20
Tried to set unknown variable or flag. Trying to set an undefined variable of flag. Also
could be a typo.
21
Tried to set an incorrect value. Many variables have a range such as the Run Current
(RC) which is 1 to 100%. As an example, you cannot set the RC to 110%.
22
VI is set greater than or equal to VM. The Initial Velocity is set equal to, or higher than
the Maximum Velocity. VI must be less than VM.
23
VM is set less than or equal to VI. The Maximum Velocity is set equal to, or lower
than the Initial Velocity. VM must be greater than VI.
24
Illegal data entered. Data has been entered that the device does not understand.
25
Variable or flag is read only. Read only flags and variables cannot be set.
26
Variable or flag is not allowed to be incremented or decremented. IC and DC cannot
be used on variables or flags such as Baud and Version.
27
Trip not defined.Trying to enable a trip that has not yet been defined.
28
WARNING! Trying to redefine a program label or variable. This can be caused when
you download a program over a program already saved. Before downloading a new
or edited program, type <FD> and press ENTER to return the device to the Factory
Defaults. You may also type <CP> and press ENTER to Clear the Program.
29
Trying to redefine a built in command, variable or flag.
30
Unknown label or user variable. Trying to Call or Branch to a Label or Variable that
has not yet been defined.
Revision R062812
9.2
No Error
9-1
9 Error Codes
9.3
Revision R062812
9.4
9-2
MCode Programming and Software Reference
31
Program label or user variable table is full. The table has a maximum capacity of 22
labels and/or user variables.
32
Trying to set a label (LB). You cannot name a label and then try to set it to a value.
Example: Lable P1 (LB P1 ). The P1 cannot be used to set a variable such as
P1=1000.
33
Trying to SET an Instruction.
34
Trying to Execute a Variable or Flag
35
Trying to Print Illegal Variable or Flag
36
Illegal Motor Count to Encoder Count Ratio
37
Command, Variable or Flag Not Available in Drive
38
Missing parameter separator
39
Trip on Position and Trip on Relative Distance not allowed together
Program errors
40
Program not running. If HOLD (H) is entered in Immediate Mode and a program is not
running.
41
Stack overflow
42
Illegal program address. Tried to Clear, List, Execute, etc. an incorrect Program address.
43
Tried to overflow program stack. Calling a Sub-Routine or Trip Routine with no Return.
44
Program locked. User Programs can be Locked with the <LK> command. Once
Locked, the program cannot be listed or edited in any way.
45
Trying to Overflow Program Space.
46
Not in Program Mode.
47
Tried to Write to Illegal Flash Address
48
Program Execution stopped by I/O set as Stop.
Communications errors
60
Not used
61
Trying to set illegal BAUD rate. The only Baud Rates accepted are those listed on the
Properties Page of IMS Terminal. (4,800, 9,600, 19,200, 38,400, 115,200)
62
IV already pending or IF Flag already TRUE.
63
Character over-run. Character was received. Processor did not have time to process
it and it was over-written by the next character.
64
Startup Calibration failed (Hybrid only)
MCode Programming and Software Reference
9.5
9.6
System errors
70
FLASH Check Sum Fault
71
Internal Temperature Warning, 10C to Shutdown
72
Internal Over TEMP Fault, Disabling Drive
73
Tried to SAVE while moving
74
Tried to Initialize Parameters (IP) or Clear Program (CP) while Moving
75
Linear Overtemperature Error (For units without Internal Over Temp)
Motion errors
80
HOME switch not defined. Attempting to do a HOME (H) sequence
but the Home Switch has not yet been defined.
81
HOME type not defined. The HOME (HM or HI) Command has been
programmed but with no type or an illegal type. (Types = 1, 2, 3, or 4)
82
Went to both LIMITS and did not find home. The motion encroached
both limits but did not trip the Home switch. Indicates a possible bad
switch or a bad circuit.
83
Reached plus LIMIT switch. The LIMIT switch in the plus direction
was tripped.
84
Reached minus LIMIT switch. The LIMIT switch in the minus direction
was tripped.
85
MA or MR isn’t allowed during a HOME and a HOME isn’t allowed
while the device is in motion.
86
Stall detected. The Stall Flag (ST) has been set to 1.
87
88
89
Revision R062812
9 Error Codes
MDrive
In Clock Mode, JOG not allowed
Hybrid
Not allowed to change AS mode while calibrating
MDrive
Following error
Hybrid
Moves not allowed while calibration is in progress.
MDrive
Reserved
Hybrid
Calibration not allowed while motion is in progress.
90
Motion Variables are too low switching to EE=1
91
Motion stopped by I/O set as Stop.
92
Position Error in Closed loop. motor will attempt tp position the shaft
within the deadband, After failing 3 attempts Error 92 will be generated. Axis will continue to function normally.
93
MR or MA not allowed while correcting position at end of previous
MR or MA.
94
Clear Locked Rotor Fault not allowed while in
Motion. MDrive Hybrid products(MAI) only.
9-3
9 Error Codes
Revision R062812
9.7
9-4
MCode Programming and Software Reference
Hybrid errors
100
Configuration test done, encoder resolution mismatch
101
Configuration test done, encoder direction incorrect
102
Configuration test done, encoder resolution and direction incorrect
103
Configuration not done, drive not enabled
104
Locked rotor
105
Maximum position count reached
106
Lead limit reached
107
Lag limit reached
108
Reserved
109
Calibration failed
WARRANTY
TWENTY-FOUR (24) MONTH LIMITED WARRANTY
Schneider Electric Motion USA warrants only to the purchaser of the Product from Schneider Electric Motion USA (the “Customer”) that the product
purchased from Schneider Electric Motion USA (the “Product”) will be free from defects in materials and workmanship under the normal use and service for
which the Product was designed for a period of 24 months from the date of purchase of the Product by the Customer. Customer’s exclusive remedy under
this Limited Warranty shall be the repair or replacement, at Company’s sole option, of the Product, or any part of the Product, determined by Schneider
Electric Motion USA to be defective. In order to exercise its warranty rights, Customer must notify Company in accordance with the instructions described
under the heading “Obtaining Warranty Service”.
NOTE: MDrive Motion Control electronics are not removable from the motor in the field. The entire unit must be returned to the factory
for repair.
This Limited Warranty does not extend to any Product damaged by reason of alteration, accident, abuse, neglect or misuse or improper or inadequate
handling; improper or inadequate wiring utilized or installed in connection with the Product; installation, operation or use of the Product not made in strict
accordance with the specifications and written instructions provided by IMS; use of the Product for any purpose other than those for which it was designed;
ordinary wear and tear; disasters or Acts of God; unauthorized attachments, alterations or modifications to the Product; the misuse or failure of any item or
equipment connected to the Product not supplied by Schneider Electric Motion USA; improper maintenance or repair of the Product; or any other reason
or event not caused by Schneider Electric Motion USA.
Schneider Electric Motion USA HEREBY DISCLAIMS ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL, EXPRESS OR IMPLIED BY
LAW OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR
PURPOSE. CUSTOMER’S SOLE REMEDY FOR ANY DEFECTIVE PRODUCT WILL BE AS STATED ABOVE, AND IN NO EVENT WILL IMS BE LIABLE
FOR INCIDENTAL, CONSEQUENTIAL, SPECIAL OR INDIRECT DAMAGES IN CONNECTION WITH THE PRODUCT.
This Limited Warranty shall be void if the Customer fails to comply with all of the terms set forth in this Limited Warranty. This Limited Warranty is the
sole warranty offered by Schneider Electric Motion USA with respect to the Product. Schneider Electric Motion USA does not assume any other liability in
connection with the sale of the Product. No representative of Schneider Electric Motion USA is authorized to extend this Limited Warranty or to change it
in any manner whatsoever. No warranty applies to any party other than the original Customer.
Schneider Electric Motion USA and its directors, officers, employees, subsidiaries and affiliates shall not be liable for any damages arising from any loss
of equipment, loss or distortion of data, loss of time, loss or destruction of software or other property, loss of production or profits, overhead costs, claims
of third parties, labor or materials, penalties or liquidated damages or punitive damages, whatsoever, whether based upon breach of warranty, breach of
contract, negligence, strict liability or any other legal theory, or other losses or expenses incurred by the Customer or any third party.
OBTAINING WARRANTY SERVICE
If the Product was purchased from an Schneider Electric Motion USA Distributor, please contact that Distributor to obtain a Returned Material Authorization
(RMA). If the Product was purchased directly from Schneider Electric Motion USA, please contact Customer Service at info@motion.schneider-electric.
com or 860-295-6102 (Eastern Time Zone).
Customer shall prepay shipping charges for Products returned to Schneider Electric Motion USA for warranty service and Schneider Electric Motion USA
shall pay for return of Products to Customer by ground transportation. However, Customer shall pay all shipping charges, duties and taxes for Products
returned to Schneider Electric Motion USA from outside the United States.
Schneider Electric Motion USA
370 North Main Street, P.O. Box 457
Marlborough, CT 06447 - U.S.A.
Tel. +00 (1) 860 295-6102 - Fax +00 (1) 860 295-6107
e-mail: info@imshome.com
http://motion.schneider-electric.com
© Schneider Electric Motion USA All Rights Reserved.
Product Disclaimer and most recent product information at
motion.schneider-electric.com.