Table of Contents
SAFETY PRECAUTIONS..................................................................................................... 3
COMMONLY ASKED QUESTIONS AND ANSWERS.............................................................. 7
SPECIFICATIONS............................................................................................................... 9
INSTALLATION................................................................................................................ 10
Installation Instructions.......................................................................................... 10
Pre-Delivery Procedure........................................................................................... 11
Delivery Procedure.................................................................................................. 12
Wireless Remote Control Programming.................................................................. 14
Headboard Installation............................................................................................ 16
Wi-Fi Module and TEMPUR-Ergo™ Smart Control Device Setup............................... 18
OPERATION..................................................................................................................... 22
Wireless Remote Control Features.......................................................................... 22
Operating Instructions............................................................................................. 23
TEMPUR-Ergo™ Smart Control Operating Instructions............................................ 27
ADVANCED REMOTE CONTROL PROGRAMMING............................................................. 28
SPECIAL FUNCTIONS...................................................................................................... 30
Reset....................................................................................................................... 30
Emergency Power-Down......................................................................................... 30
Change from Tandem System to Single System....................................................... 30
Using Factory Reset for the Wi-Fi Module............................................................... 31
TROUBLESHOOTING....................................................................................................... 32
Conforms to UL Standard 962.
Certified to CSA Standard
C22.2 No. 68.
CUSTOMER SERVICE: 1-800-887-4321
2
Safety Precautions
Safety Precautions
WARNING!
• Keep the cord away from heated surfaces.
• Never operate the furnishing with the air openings blocked.
IMPORTANT SAFETY
Keep the air openings free of lint, hair and the like.
INSTRUCTIONS.
• Never drop or insert any object into any opening.
• Do not use outdoors.
PLEASE READ THESE
• Do not operate where aerosol (spray) products are
INSTRUCTIONS
being used or where oxygen is being administered.
•
To disconnect, turn all controls to the off position,
THOROUGHLY BEFORE
then remove plug from outlet.
USING THIS PRODUCT.
SAVE THESE INSTRUCTIONS! WARNING!
service center for examination and repair.
Your TEMPUR-Ergo™ Premier system has been
Risk of Injury — keep children away from extended
designed to provide you with the reliable operation and
foot support (or other similar parts).
durability you expect. This product has been inspected
WARNING!
and tested prior to shipment.
When using an electrical furnishing, basic precautions
should always be followed, including the following:
READ ALL INSTRUCTIONS BEFORE USING YOUR
TEMPUR-ERGO PREMIER.
Risk of electric shock — connect this furnishing
to a properly grounded outlet only. See grounding
instructions.
GROUNDING INSTRUCTIONS
This product must be grounded. If it should malfunction
DANGER
or breakdown, grounding provides a path of least
To reduce the risk of electric shock:
resistance for electric current to reduce the risk of
• Always unplug this furnishing from the electrical
electric shock. This product is equipped with a cord
having an equipment-grounding conductor and
outlet before cleaning.
a grounding plug. The plug must be plugged into
WARNING!
an appropriate outlet that is properly installed and
To reduce the risk of burns, fire, electric shock, or injury
to persons:
• Unplug from outlet before putting on or taking off parts.
• Close supervision is necessary when this furnishing is
used by, or near children, invalids, or disabled persons.
• Use this furnishing only for its intended use
as described in these instructions. Do not use
attachments not recommended by the manufacturer.
• Never operate this furnishing if it has a damaged cord
or plug, is not working properly, has been dropped or
damaged, or dropped in water. Return the furnishing to a
grounded in accordance with all local codes and
ordinances.
DANGER
Improper connection of the equipment-grounding
conductor can result in a risk of electric shock. Check
with a qualified electrician or serviceman if you are in
doubt as to whether the product is properly grounded.
Do not modify the plug provided with the product. If it
will not fit the outlet, have a proper outlet installed by a
qualified electrician.
CUSTOMER SERVICE: 1-800-887-4321
3
TEMPUR-Ergo Premier
™
SAVE THESE
INSTRUCTIONS!
GROUNDING SAFETY
This product is for use on a nominal 120-volt circuit,
and has a grounding plug that looks like the plug
illustrated in sketch A (see figure). A temporary adapter
FOR BEST RESULTS, YOUR TEMPUR‑Ergo™
as illustrated in sketches B and C can be used to
Premier SHOULD BE PLUGGED INTO A SURGE
connect this plug to a 2-pole receptacle as shown in
PROTECTOR (not included).
sketch B if a properly grounded outlet is not available.
The temporary adapter should be used only until a
properly grounded outlet (sketch A) can be installed
by a qualified electrician. The green coloured rigid ear,
lug, or the like extending from the adapter must be
connected to a permanent ground such as a properly
grounded outlet box cover. Whenever the adapter
is used, it must be held in place by a metal screw.
This product is for use on a circuit having a nominal
rating of more than 120 volts and is factory equipped
with a specific electric cord and plug to permit
connection to a proper electric circuit. Make sure that
the product is connected to an outlet having the same
configuration as the plug. No adapter should be used
with this product. If the product must be reconnected
for use on a different type of electric circuit, the
reconnection should be made by qualified service
personnel.
WARRANTY PRECAUTION!
Do not open control box, motors or wireless
remote control (with the exception of the battery
compartments). The warranty is void if these units
are tampered with. Any repair or replacement of
TEMPUR‑Ergo Premier parts must be performed by
an authorized service person.
IN-HOME USE AND HOSPITAL DISCLAIMER
Your TEMPUR‑Ergo Premier is strictly designed for
in-home use only. It is NOT designed for hospital
use and is NOT designed to meet hospital standards.
DO NOT USE this bed with TENT TYPE oxygen
therapy equipment or near explosive gases.
WARNING!
DO NOT USE NEAR PEOPLE USING OR WEARING
MEDICAL DEVICES. FOR HOUSEHOLD / RESIDENTIAL
USE ONLY. DO NOT USE OUTDOORS.
Unauthorized modifications could void the electrical
portion of your warranty. Failure to use a properly
grounded outlet for this product or modification of the
plug will compromise this important grounding safety
feature and may result in electric shock, electrical fire,
or faulty operation of the product.
CUSTOMER SERVICE: 1-800-887-4321
4
Safety Precautions
IMPORTANT SAFETY FEATURES
Use this furnishing only for its intended use as
described in these instructions. Do not use attachments
not recommended by the manufacturer.
If there is an overload weight condition on the head or
foot mechanism, the control unit will automatically stop
the corresponding functions. Once the excess weight
is removed, the control unit will automatically allow all
SMALL CHILDREN AND
PETS WARNING
After your TEMPUR-Ergo Premier has been unboxed,
immediately dispose of packaging as it can smother
small children and pets. To avoid injury, children and
pets should not be allowed to play on or under the
bed. Children should not operate this product without
functions to resume.
adult supervision. Close supervision is necessary when
Locking casters are available for aftermarket purchase.
disabled persons.
In order to prevent the movement of this product with
SAVE THESE INSTRUCTIONS!
this furnishing is used by, or near children, invalids, or
casters, all four casters should be in the locked position.
This can be accomplished by pushing down the locking
latch on the caster. To resume mobility of the product,
lift the locking latch up. You are strongly encouraged to
place rubber caster cups or carpet squares under the
casters in addition to locking them in place if the product
Your TEMPUR-Ergo Premier has been designed to
provide you with the reliable operation and durability
you expect. This product has been inspected and
tested prior to shipment.
is positioned on a hard surface floor such as hardwood,
SERVICE REQUIREMENTS
tile or linoleum. Although the casters are locked and will
Service technicians are not responsible for moving
not roll, they may slide.
furniture, removing headboards and footboards or
CONSUMERS WITH PACEMAKERS
As with any product that produces a vibrating motion
(optional), it is possible that some pacemakers may
interpret this motion as a false sense of movement
and/or exercise. This may or may not affect your
any items required to perform maintenance on your
adjustable bed. In the event the technician is unable to
perform service due to lack of accessibility, the service
call will be billed to the purchaser and the service will
be re-scheduled.
pacemaker. If you have any concerns, please consult
your physician. For information on disabling the
vibrating motors, please contact customer service
by calling 1-800-887-4321.
USER-SERVICEABLE PARTS
This product is specifically designed to be
maintenance-free for the user. Therefore, you are
encouraged not to open any motors, alter the wiring,
or adjust, modify or change the structure of the
product, as it will void the warranty.
POWER RATINGS:
MODEL NO: TES200, TES300
INPUT: AC 120V VAC, 60 HZ, 2.5 A MAX
OUTPUT: DC 29V – 2.5A
CUSTOMER SERVICE: 1-800-887-4321
5
TEMPUR-Ergo Premier
™
RADIO FREQUENCY IS 433 MHZ.
INTENDED USAGE
The electric adjustable bed should be installed with
FCC COMPLIANCE
the Headboard Bracket and/or the head of the frame
This device complies with part 15 of the FCC
should be positioned close to a wall.
Rules. Operation is subject to the following
two conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.
To comply with the FCC RF exposure
compliance requirements, no change to the
antenna or the device is permitted. Any change
to the antenna or the device could result in the
device exceeding the RF exposure requirements
and void user’s authority to operate the device.
PRODUCT RATINGS
The lift motors in your TEMPUR-Ergo™ Premier are
NOT designed for continuous use. Reliable operation
and full life expectancy will be attained as long as the
lift motors do not operate more than two (2) minutes
over a 20-minute period, or approximately 10% duty
cycle. Any attempt to circumvent or exceed this rating
will shorten the life expectancy of this product and
may void the warranty. The recommended weight
restrictions on our TEMPUR-Ergo Premier systems
are as follows: Twin, Twin Long, Double, Queen, Split/
Dual Queen, and Split/Dual CA King bases – up to 650
lbs. each. This TEMPUR-Ergo Premier will structurally
support the recommended weight distributed evenly
across the head and foot sections. This product is not
designed to support or lift this amount of weight in the
head or foot sections alone.
NOTE: Exceeding the recommended weight
restrictions could damage your TEMPUR‑Ergo
Premier and void your warranty.
For best performance, you should enter and exit the
TEMPUR‑Ergo Premier while it is in the flat or fully
lowered position.
CUSTOMER SERVICE: 1-800-887-4321
6
Questions and Answers
Commonly asked Questions and Answers
WHAT IS THE HEIGHT OF THE TEMPUR‑ERGO PREMIER
ADJUSTABLE BASE?
The overall height ranges from approximately 9 to 19.75"
inches from the floor to the bottom of the mattress. See
chart on page 9 for available options.
DOES THE TEMPUR‑ERGO PREMIER COME WITH
HEADBOARD ATTACHMENTS?
No. A headboard bracket kit is sold separately.
DOES THE TEMPUR-ERGO PREMIER COME WITH
FOOTBOARD ATTACHMENTS?
No, you cannot attach a footboard directly to the
TEMPUR-Ergo Premier. However, you can use a
“freestanding” bed including headboard, footboard
and side rails by placing the complete TEMPUR-Ergo
Premier within the assembled bed. It may be easiest
to assemble the bed around the adjustable base. You
should measure the inside dimensions of the assembled
bed to be sure adjustable base will fit. One of our riser
leg sets may be required in some cases.
WILL THE TEMPUR-ERGO PREMIER FIT INSIDE
EXISTING FURNITURE?
The TEMPUR-Ergo Premier is designed to fit into most
“freestanding” beds. We always recommend you measure
the inside dimensions of the assembled bed to be sure
the TEMPUR-Ergo Premier will fit. Please refer to the
specifications on page 9 for dimensions of the base. One
of our riser leg sets may be required in some cases.
The adjustable base should not be used in conjunction
with bed slats. The weight of the base can cause slats
to break. Slats should be removed or the base height
should be adjusted such that the base stands above the
slats and the slats bear no weight. Clearance of 1.5 to 2"
is highly recommended.
WHERE IS THE SERIAL NUMBER ON THE
TEMPUR‑ERGO PREMIER?
The serial number can be found on the law tag attached
to the cover, the power supply under the base and on
the frame right below the foot end of the base. It may be
easier to see by lifting the foot slightly if possible. The
serial number is also located on a sticker on the back
cover of the Complete Reference Guide (owner’s manual)
shipped with the base.
DOES THE UNIT HAVE AC OR DC MOTORS?
The lift motors used on the TEMPUR-Ergo Premier are
DC motors. The base’s power supply converts the AC
power from the wall outlet to DC power.
WHO DO I CALL FOR SERVICE OR SUPPORT IF NEEDED?
Service and technical support is available by calling our
dedicated customer service group at 1-800-887-4321.
An owner’s manual is included with each base including
other information for making claims.
IS AN EXTENDED WARRANTY AVAILABLE?
No.
DO I GET A FULL WARRANTY IF I PURCHASE A FLOOR
MODEL?
Yes. However, your warranty start date is the date of
manufacture which is clearly marked on the law tag
attached to the base (not your actual purchase date).
WHAT ARE THE ELECTRICAL REQUIREMENTS OF THE
TEMPUR-ERGO PREMIER?
During normal operation, the base can draw up to 2.5A
of electricity from a normal AC wall outlet.
WHAT IS THE WI-FI MODULE?
The Wi-Fi Module is a device included with
TEMPUR-Ergo Premier adjustable base that allows you
to control the system with a supported smart device.
CUSTOMER SERVICE: 1-800-887-4321
7
TEMPUR-Ergo Premier
™
WHICH SMART DEVICES ARE SUPPORTED?
• Mobile phones and tablet computers running Android™
operating system version 2.3 or higher, and with Wi-Fi
capabilities (specifically 802.11 b/g at 2.4GHz).
• Apple® iPhone,® iPod touch,® iPad,® and iPad® mini
devices running iOS version 5.0 and higher.
• Kindle Fire HD and HDX
I’M NOT SURE WHETHER MY SMART DEVICE IS
COMPATIBLE WITH THE WI-FI MODULE AND APP.
Contact the manufacturer of your device for
confirmation.
WHICH WIRELESS ROUTERS ARE SUPPORTED?
Wireless routers must have the following specifications:
• 802.11 b/g on 2.4GHz
• UDP Port 50007 and TCP Port 2000 must be open
• Must support one of the following encryption modes:
none, WPA PSK, WPA2 PSK
• The character “^” must not be used in the SSID
(network name) or in the network’s encryption
password
• The router must have sufficient range to comfortably
reach the Wi-Fi Module of the adjustable base as well
as the smart device
WHAT IS THE DIFFERENCE BETWEEN HOME NETWORK
MODE AND DIRECT MODE? WHICH ONE SHOULD I USE?
The direct mode makes a connection between your
smart device and the adjustable base’s included Wi-Fi
Module. This is the quickest way to make a connection,
but it doesn’t allow you to access your home network,
which may prevent you from using Internet-based
functions on your smart device while controlling
your bed.
The home network mode integrates the Wi-Fi Module
into your home wireless network. This means that your
smart device can control your adjustable base, but it can
also continue to access the Internet or other devices on
your home network.
Most owners with a home wireless network will want to
use home network mode.
IPAD® AND IPHONE® ARE REGISTERED TRADEMARKS OF APPLE, INC., CUPERTINO, CA.
ANDROID™ IS A TRADEMARK OF GOOGLE INC., MOUNTAIN VIEW, CA.
KINDLE™ IS A TRADEMARK OF AMAZON.COM INC., SEATTLE, WA
CUSTOMER SERVICE: 1-800-887-4321
8
Specifications
Bed Type
Specifications
A. Frame
Width
Twin Long
24 3/4"
B. Base
Width
C. Base
Length
37 1/2"
Weight
79"
173 lb
Double
39 1/2"
53 1/4"
75"
219 lb
Queen
39 1/2"
58 1/4"
79"
235 lb
9"
A
B
C
7"
17 1/4"
54 3/4"
Measurements are approximate.
Appearance may vary depending upon model.
No Leg
(rubber foot)
Caster Only
4 1/2" Riser Leg
(without caster)
4 1/2" Riser Leg
(with caster)
6 1/2" Riser Leg
(without caster)
6 1/2" Riser Leg
(with caster)
9" Riser Leg
(without caster)
9” Riser Leg
(with caster)
F
F
F
E
F
E
E
F
F
F
E
D
F
E
E
E
D
D
D
D
D
3/4"
3 1/4"
4 1/2"
7"
6 1/2"
9"
9"
11 1/2"
E) To Base
2"
4 1/2"
5 3/4"
8 1/4"
7 3/4"
10 1/4"
10 1/4"
12 3/4"
F) To Mattress
9"
11 1/2"
12 3/4"
15 1/4"
14 3/4"
17 1/4"
17 1/4"
19 3/4"
D) To Frame
D
E
CUSTOMER SERVICE: 1-800-887-4321
9
TEMPUR-Ergo Premier
™
Installation Instructions
Before discarding any packing materials, check your
TEMPUR-Ergo™ Premier carton and verify the following
Appearance of some parts may differ from photos.
Headboard brackets not included.
items in the parts list are included:
PARTS LIST
A.
B.*
C.*
D.*
E.
F.
G.
H.
A. Wireless Remote Control (1) and
AA Batteries (2)
B. Mattress Retainer Bar (1)*
C. Retainer Bar Bolt (4)*
D. Retainer Bar Plate (2)*
E. Legs (4)
F. Connection Cable (1) - (Only on Twin Long)
G. Power Cord (1)
H. 9-Volt Batteries (2)
*Attached to base for shipping.
CUSTOMER SERVICE: 1-800-887-4321
10
Installation
Pre-Delivery Procedure
STEP 1
STEP 5
Lift carton top off box to reveal the bottom
of the base.
Once the warehouse test is successful and complete:
• Unplug the power extension cord
• Remove the batteries from the remote control and
STEP 2
Remove power cord from accessory pack and plug
into power supply. Using a power extension cord to
reach the base, plug in the base’s power cord.
NOTE: Do not uncoil the base power cord which
is packaged for shipment.
return both to the accessory pack
• Remove the power cord and return it to the
accessory pack
• Place the lid back on the outer carton and secure
for delivery
NOTE: Always keep the Ergo base in a flat,
horizontal position during transportation and
STEP 3
Remove the remote control and (2) AA batteries
from the accessory pack, remove the cover from the
remote control’s battery compartment, and install
the batteries.
delivery.
NOTE: To avoid damage to the TEMPUR‑Ergo
Premier, always open the carton while the bed
is in the flat position.
NOTE: Do not mix old and new batteries.
STEP 4
Power Test Procedure:
Press each of the following buttons long enough to
illuminate the green LED signature light on the
OPEN FLAT
remote control, and watch/listen for the base to
activate. This ensures you will be delivering a base
that is fully functional. Test the base by pressing the
buttons in the following sequence.
1.Head Lift
5.Leg Massage
2.Leg Lift
6.Stop
3.Head Massage
7.Flat
4.Lumbar Massage
NOTE: Only press each button long enough to
hear or see the function activate on the base.
CUSTOMER SERVICE: 1-800-887-4321
11
TEMPUR-Ergo Premier
™
Delivery Procedure
NOTE: Always keep the TEMPUR-Ergo™
STEP 4
Premier in a flat, horizontal position during
Remove the remote control and (2) AA batteries
transportation and delivery. Always open the
from the accessory pack, remove the cover from the
box in the flat position.
remote control’s battery compartment, and install
the (2) AA batteries into the remote.
STEP 1
Carefully take base in the carton to the bedroom and
place next to where the customer wants it set up.
STEP 2
Carefully lift the TEMPUR‑Ergo Premier out of
the shipping carton, keeping the unit topside down.
For safety reasons, this should be performed by
two people.
NOTE: To avoid damage
Cut power supply free from its attachment to the
frame. Install (2) 9-Volt batteries into the battery
compartment of the power supply.
to the adjustable base,
OPEN FLAT
always open the carton
while the bed is in the
flat position.
Remove power cord from accessory pack and plug
into power supply.
STEP 3
The products come packed in a cardboard box.
Some components are also sealed in plastic film.
To unpack, proceed as follows:
STEP 3A
NOTE: Do not mix old and new batteries.
STEP 5
Thread the power cable through the strain-relief
hooks on the power supply.
Remove the cardboard and plastic film from the
Snap in the power cords to the hooks
components.
The purpose of the hooks is to relieve the cable
STEP 3B
Check the package contents.
connector. It protects the power cord from damage.
STEP 3C
Dispose of the packaging materials.
STEP 3D
Keep the user manual at hand for the operators.
NOTE: Ensure the cables are not under tension
Uncoil power supply and place on the floor.
Connect the power lead from the power supply to
the surge protector (not included).
CUSTOMER SERVICE: 1-800-887-4321
12
Installation
STEP 6
STEP 10
Attach TEMPUR‑Ergo Premier Legs: Open the
Place the mattress(es) on the base(s).
accessories box, take out the (4) legs, and thread
them in a clockwise direction into the pre-threaded
holes in the frame.
STEP 11
Ensure the power switch on the surge protector is in
NOTE: Hand tighten the legs securely to the
the “on” position and that it is plugged into the wall
frame. DO NOT over tighten. Make sure the legs
outlet. Check the system for functionality with the
are screwed completely into the frame. Legs
mattress in place.
that are not securely attached may become
NOTE: If the system does not respond, follow
unsafe. DO NOT unscrew a leg to compensate
the Setup Procedure on page 14 to ensure the
for an uneven floor.
base and remote control are communicating.
NOTE: Locking casters are available for
aftermarket purchase. In order to prevent the
movement of this product, all four casters
should be in the locked position.
STEP 7
Carefully flip the TEMPUR‑Ergo Premier over to the
topside up position.
NOTE: Make sure to lift the adjustable base off
the ground before flipping over. DO NOT use legs
as a leverage point to ensure they do not break.
!
ATTENTION ! Improper handling
DO NOT
lean the bed against the
installed legs to flip it over.
STEP 8
!
Proper handling
Turn bed over without leaning against the
Remove retainer bar and install in upright position
installed legs.
using a standard screw driver or hex head driver
(not provided).
STEP 9
If this delivery involves dual bases and/or split
mattresses, program accordingly. (Program remote
control(s) per the instructions contained in the
Complete Reference Guide.)
CUSTOMER SERVICE: 1-800-887-4321
13
TEMPUR-Ergo Premier
™
Wireless Remote Control Programming
SETUP PROCEDURE — SINGLE BASE OR TWO BASES
OPERATING INDEPENDENTLY
NOTE: The remote control included with the
SETUP PROCEDURE — TWO BASES OPERATING IN
TANDEM BY A SINGLE REMOTE
Follow these simple steps to set up a tandem system.
TEMPUR-Ergo Premier adjustable base
™
will already be programmed to operate the
accompanying base without any additional setup.
Follow these steps if you replace your remote control or
if your base does not function out of box.
STEP 1
Ensure two (2) AA batteries have been inserted into
STEP 1
Ensure two (2) AA batteries have been inserted into one
wireless remote control. Store extra remote for future use.
NOTE: Do not mix old and new batteries.
STEP 2
Ensure both TEMPUR‑Ergo Premier bases are
disconnected from power.
the wireless remote control.
NOTE: Do not mix old and new batteries.
STEP 2
Ensure the TEMPUR-Ergo Premier is disconnected
from power.
STEP 3
Install connection cable by inserting one connector
into each control box, pairing together both bases.
STEP 3
Press and hold the FLAT and STOP buttons
simultaneously for at least 10-15 seconds. The
current RF channel number will be shown on the
LCD screen.
STEP 4
Press the FLAT button to confirm the RF channel
number. The RF channel number will flash for 30
seconds.
STEP 5
Within 30 seconds, reconnect the TEMPUR-Ergo
Premier power supply to a working outlet. You
will hear two “double-clicks” when the set-up is
successfully completed. You may use the remote
when the RF channel stops flashing. Alternately,
you can press the STOP button to stop the RF
channel from flashing.
NOTE: Pressing the STOP button prematurely
will cause the set-up process to fail and require
you to repeat Steps 1-5.
STEP 4
Press and hold the FLAT and STOP buttons
simultaneously on the remote control for 10-15
seconds. The current RF channel number will be shown
on the LCD screen.
STEP 5
Press the FLAT button to confirm the RF channel
number. The RF channel number will flash for 30
seconds. Within this 30 seconds, reconnect the
first base into the power outlet. You will hear two
“double clicks”. Then reconnect the second base to
a working outlet (within the same 30 seconds).
You will again hear two “double-clicks”.
CUSTOMER SERVICE: 1-800-887-4321
14
Installation
STEP 6
Perform System Reset: Press and hold the FLAT
button (7). After 15 seconds, the LCD changes from
FLAT to RST - do not release the FLAT button!
Continue holding the FLAT button for an additional
30-60 seconds as the bed moves forward and
backward. The reset process is complete when no
audible clicks or movement occurs for a minimum of
10 seconds.
STEP 5
Press and hold the FLAT and STOP buttons
simultaneously on the first remote for 10-15
seconds. The current RF channel number will be
shown on the LCD screen. Enter the first then the
second pre-selected digits from step 4. Then press
the FLAT button on the first remote to confirm the
RF channel. The RF channel number will flash for 30
seconds.
SETUP PROCEDURE — TWO BASES OPERATING IN
TANDEM BY TWO REMOTES
Follow these instructions to set up a tandem system
which can be operated by either remote.
STEP 6
Within 30 seconds, reconnect the first base into the
power outlet. You will hear two “double clicks”.
STEP 7
To program the second remote, repeat steps 5 - 6
STEP 1
Ensure two (2) AA batteries have been inserted into
each wireless remote control.
NOTE: Do not mix old and new batteries.
STEP 2
Ensure both TEMPUR‑Ergo Premier bases are
disconnected from power.
STEP 8
Perform System Reset: Press and hold the FLAT
button (7). After 15 seconds, the LCD changes from
FLAT to RST.
NOTE: Do not release the FLAT button!
Continue holding the FLAT button for an additional
30-60 seconds as the bed moves forward and
STEP 3
Install connection cable by inserting one connector
into each control box, pairing together both bases.
backward. The reset process is complete when no
audible clicks or movement occurs for a minimum of
10 seconds.
STEP 4
The following buttons are used to set the first and
second parts of the RF channel number:
1: Memory 1
5: Head Up
2: Memory 2
6: Head Down
3: Memory 3
7: Leg Up
4: Memory 4
8: Leg Down
Please pre-select two digits and make a note of your
selection for the following steps.
CUSTOMER SERVICE: 1-800-887-4321
15
TEMPUR-Ergo Premier
™
Headboard Installation
NOTE: HEADBOARD BRACKET KIT SOLD SEPARATELY.
Before discarding any packing materials, check your
Headboard Bracket Kit and verify the following items
in the parts list are included:
STEP 1B
Place the Inner Headboard Bracket (A) over the square
tube frame making sure the open side of the channel is
PARTS LIST
facing outboard.
A. Inner Headboard Bracket (2)
B. Outer Headboard Bracket (2)
Align two (2) holes from the pattern of the Inner
Headboard Bracket (A) with the two (2) holes of the
C. Frame Bolt (4)
square tube frame such that a distance of
D. Lock Washer (12)
approximately 1.5 inches to 2 inches exists between
E. Bracket Bolt (8)
the edge of the TEMPUR-Ergo Premier adjustable base
and the Headboard Bracket assemblies.
F. Locking Nut (12)
TOOLS REQUIRED
The middle setting is for Twin Long and Queen.
Flat Head Screwdriver
The interior setting is for Double.
Wrench (7/16")
NOTE: This step is needed if using a headboard
ONLY; not headboard, footboard and side rails.
Place the two (2) Frame Bolts (C) with two (2) Lock
Washers (D) through the holes and fasten with Locking
Nuts (F).
NOTE: Failure to follow the proper headboard
bracket installation instructions may result in
damage to your TEMPUR‑Ergo™ Premier.
WARNING: The bottom of the headboard cross
member must be positioned so that there is no
more than 3 inches between the bottom of the
headboard and the top of the mattress. Failure
to follow this instruction could result in serious
injury or death to a person or pet caught
between the mattress and the headboard.
Hand tighten the Frame Bolt and Locking Nut in place
using a flat head screwdriver and a crescent wrench.
STEP 1
Assemble the Headboard Bracket:
Repeat on other side of the frame.
STEP 1A
Use the wireless remote to raise the head of the
bed in order to gain access to the TEMPUR‑Ergo
Premier frame.
CUSTOMER SERVICE: 1-800-887-4321
16
Installation
STEP 1C
STEP 2C
Place the open side of the Outer Headboard Bracket
If the Headboard Brackets require adjustment,
(B) over the rectangular plate of the Inner Headboard
loosen the bolts that are holding the Outer
Bracket (A).
Headboard Brackets and move them so that the
mounting holes on the Outer Headboard Bracket
align with the mounting holes on your headboard.
Reinstall the bolts on the Outer Headboard Bracket
and firmly tighten.
STEP 2D
Place your headboard bolts through the mounting
holes on both the Outer Headboard Bracket and
your headboard. Firmly tighten.
STEP 3
Place four (4) Bracket Bolts (E) with four (4) Lock
Washers (D) through the slots of the Outer
®
Place your Tempur-Pedic mattress on top of your
TEMPUR‑Ergo Premier.
Headboard Bracket (B) and into the holes of the
Inner Headboard Bracket (A). Use four (4) Locking
Nuts (F) to secure the brackets in place, but loose
enough to allow adjustment.
WARNING: Verify the space between the
headboard cross member and the top of the
mattress is no more than 3 inches.
Repeat on other side of the frame.
STEP 2
Your TEMPUR-Ergo Premier installation is now
complete. Refer to the Wireless Remote Control Guide
on the following pages or the supplied Quick Reference
Attach your headboard to the Headboard Brackets
Guide for additional usage instructions.
following the steps below:
STEP 2A
Measure the center-to-center distance of the
mounting holes in your headboard.
STEP 2B
Measure the center-to-center distance of the
mounting holes in the Headboard Bracket
assemblies.
CUSTOMER SERVICE: 1-800-887-4321
17
TEMPUR-Ergo Premier
™
Wi-Fi Module and TEMPUR-Ergo Smart Control Device Setup
™
Before you begin your smart device setup, make sure
Apple® iOS device
your adjustable base is connected to a power source.
INSTALLING THE TEMPUR-ERGO™ SMART CONTROL APP
Follow the instructions in this section to install the
TEMPUR-Ergo Smart Control App on your smartphone
or tablet and pair the Wi-Fi Module on the bed to the
Android™ device
App. The steps contain instructions for use with either
an Apple® iOS or an Android™ smartphone or tablet and
the example screens shown include those for an Apple®
iOS device and an Android™ device.
STEP 1
Download the TEMPUR-Ergo Smart Control App
from the App Store, Play Store, or Amazon.
STEP 2
Install the App to your smart
device. The TEMPUR-Ergo™
icon displays on your device.
NOTE: A tandem system contains two Wi-Fi Modules.
Such a tandem system can only be operated by one of the
two Wi-Fi Modules. You may need to try both modules to
MAKING A DIRECT CONNECTION TO THE BASE
STEP 1
determine the one that controls the system.
STEP 3
Before opening the app, first select the Wi-Fi network
Select the App on your smart device to start the TEMPUR-
settings of your smart device. If you have already
Ergo Smart Control App. The App looks for the Wi-Fi Module
opened the App, you may need to close it before
and displays a list of all modules found.
continuing.
Apple® iOS device
Android™ device
STEP 2
Connect to the network of your adjustable base. The
proper network name begins with “WM” followed by
a combination of 6 alpha-numeric characters and
is printed on the type plate of your Wi-Fi Module.
NOTE: When the smart device is removed from the
SSIDs do not include the letter “O” but may contain
network and returned, there may be a slight delay as it
the numeric digit zero, or “0”. The TEMPUR-Ergo
reconnects with the network.
Smart App should be used in close proximity to the
adjustable base to ensure the wireless connection is
Apple® iOS device
not interrupted. Once your Wi-Fi Module is located by
your smart device, a check mark appears to the right
of the SSID.
CUSTOMER SERVICE: 1-800-887-4321
18
Android™ device
Installation
If you experience a delay, due to the smart device being
removed and then returned to the network, follow steps
STEP 2
Tap the Setting icon
3A and 3B to resolve.
on your TEMPUR-Ergo
Smart Control App on your smart device.
STEP 3A
Select the correct Wi-Fi network in the Settings
screen of your smart device and restart the App.
STEP 3
Tap the
next to the appropriate Wi-Fi Module.
STEP 3B
NOTE: If your home network utilizes “MAC
Check the distance between your smart device and
Address Filtering” as a security feature you
the Wi-Fi Module.
MUST do this prior to Step 4.
Tap on “Show App and Wi-Fi Module
STEP 4
Information” and an information screen will
Identify the correct
appear.
module, select it,
Write down the information on the line labelled
and the system is
“MAC Address of Module” — it (the MAC
ready to operate.
address) will be a string of 8 groups, of 2
Your smart device
characters each — with each group separated by
displays a screen
a colon. You will need to add this MAC address
similar to the one
to your home network’s Filtering list so that your
shown here with all
home network will allow the Ergo bed module
of the applicable
to communicate with it. Once this is complete,
controls for your
continue to Step 4 in the App.
bed.
NOTE: If you wish to use your smart device to
access the internet through your home network,
follow the instructions in the next section,
“Using the TEMPUR-Ergo Smart Control App
™
STEP 4
Set the home network setting to ON.
Apple® iOS device
Android™ device
with Your Home Network.”
USING THE TEMPUR-ERGO™ SMART CONTROL APP
WITH YOUR HOME NETWORK
Your router for your home network uses either DHCP or
static IP settings. Most routers use the DHCP mode.
INTEGRATING WITH A DHCP HOME NETWORK
STEP 5
Select the SSID/Wi-Fi Network Name of your home
network:
STEP 5A
For Apple® iOS devices or if your SSID/Wi-Fi
Network Name is not shown in the list on your
Follow these instructions to use the App with most
Android™ device, enter your Router SSID in the
home networks.
Enter SSID Network Name field. (The SSID for your
SSID/Wi-Fi Network Name can usually be found on
STEP 1
the type plate of your router.)
Make sure your smart device is connected to the
adjustable base’s Wi-Fi network as described in
Step 2 of “Making a Direct Connection to the Base.”
CUSTOMER SERVICE: 1-800-887-4321
19
TEMPUR-Ergo Premier
™
STEP 5B
STEP 8
For Android devices, select the SSID/Wi-Fi
™
Tap Proceed. The following message appears:
Network Name from the list.
Apple® iOS device
STEP 6
Enter your password in the Password field on both
Apple® iOS and Android™ devices. For some routers,
this can also be called the Web Key.
STEP 7
Tap Save. This message informs you that the next
step can only be undone by performing a factory
reset at the Wi-Fi Module. Take care to ensure your
network name and password are correct before
Android™ device
proceeding.
Apple® iOS device
Android™ device
STEP 9
Tap OK.
STEP 10
Select the appropriate SSID/Wi-Fi Network Name
in the Settings screen of your device.
STEP 11
Start the TEMPUR-Ergo™ Smart Control App.
The App should locate the corresponding Wi-Fi
Module and be ready to operate.
WARNING: Check to be sure your SSID/Wi-Fi
Network Name and password are correct before
proceeding.
NOTE: For best performance, your router
should be in close proximity to the bed.
CUSTOMER SERVICE: 1-800-887-4321
20
Installation
INTEGRATING WITH A STATIC IP SETTING HOME
NETWORK
If your router uses a Static IP setting, follow these
STEP 3
Change Sound effects to ON.
Apple® iOS device
Android™ device
instructions to integrate your Home Network.
STEP 1
Perform step 1 through step 6 in the “Integrating
with a DHCP Home Network” section.
CHANGING THE NAME OF THE WI-FI MODULE
STEP 1
STEP 2
Change the Static IP (Expert Mode) to ON.
Apple® iOS device
Android™ device
Launch the TEMPUR-Ergo Smart Control App.
STEP 2
Tap the Settings icon
in TEMPUR-Ergo Smart
Control App.
STEP 3
Select the corresponding Wi-Fi Module by tapping
the
or the
for Apple® iOS or Android™,
respectively.
STEP 4
Enter the new name for the Wi-Fi Module in the
Name field.
STEP 3
Enter the IP Address and the Subnet Mask for your
Apple® iOS device
Android™ device
Home Network.
STEP 4
Perform step 7 through step 11 in the “Integrating
with a DHCP Home Network” section.
USING THE SETTINGS SCREEN IN THE TEMPUR-ERGO
SMART CONTROL APP
The Settings screen in the TEMPUR-Ergo Smart
Control App allows you to turn sound effects on and off
and change the name of the Wi-Fi Module.
STEP 5
Tap Save.
NOTE: See TEMPUR-Ergo Smart Control
Operating Instructions on page 27.
CONTROLLING SOUND EFFECTS
STEP 1
Launch the TEMPUR-Ergo Smart Control App.
STEP 2
Tap the Settings icon
in the TEMPUR-Ergo
Smart Control App.
CUSTOMER SERVICE: 1-800-887-4321
21
TEMPUR-Ergo Premier
™
Wireless Remote Control Features
READ ADVISORY INFORMATION IN THE SAFETY PRECAUTIONS SECTION OF THIS GUIDE CAREFULLY BEFORE
USING THIS PRODUCT. THE POTENTIAL FOR ELECTRIC SHOCK EXISTS IF ELECTRICAL COMPONENTS ARE NOT
INSTALLED OR OPERATED PROPERLY.
1. STATUS LED
2. LCD
3. HEAD UP (HU)
5. LEG UP (LU)
4. HEAD DOWN (HD)
6. LEG DOWN (LD)
7. FLAT (F)
9. MEMORY 3 AND 4
(M3 AND M4)
8. MEMORY 1 AND 2
(M1 AND M2)
12. LUMBAR MASSAGE
INTENSITY + (LUM+)
10. HEAD MASSAGE
INTENSITY + (HM+)
11. HEAD MASSAGE
INTENSITY – (HM-)
13. LUMBAR MASSAGE
INTENSITY – (LUM-)
14. LEG MASSAGE
INTENSITY + (LM+)
16. STOP MASSAGE (S)
15. LEG MASSAGE
INTENSITY – (LM-)
17. MASSAGE MODE 1:
CONSTANT
20. MASSAGE MODE 4:
PULSE
18. MASSAGE MODE 2:
WAVE
19. MASSAGE MODE 3:
SIMULTANEOUS WAVE
CUSTOMER SERVICE: 1-800-887-4321
22
Operation
Operating Instructions
To ensure safe operation of the system, please observe the following safety instructions:
CAUTION: Keep children away from electrically adjustable beds and control units. There is risk of injury
and electric shock.
CAUTION: Unplug the power cord during a thunderstorm or if you do not intend to use the system for an
extended period of time.
NOTE: Do not put the remote control button-side down. The LCD display must be facing upward.
NOTE: If the LCD is not readable any more, you may need to change the batteries. Do not mix old and
new batteries.
NOTE: The actuators will continue moving until you release button or the maximum height is reached.
MANUAL ADJUSTMENT OF HEAD AND FOOT
Leg (5,6)
Head (3,4)
This function adjusts the Head section to
This function adjusts the Leg section to the
the desired position.
desired position.
Press the HEAD UP button (3).
Press the LEG UP button (5).
Keep pressing the button until the desired
Keep pressing the button until the desired
height is reached. The LCD will show the
height is reached. The LCD will show the
following segments:
following segments:
Press the HEAD DOWN button (4).
Press the LEG DOWN button (6).
Keep pressing the button until the desired height is
Keep pressing the button until the desired height is
reached. The LCD will show the following segments:
reached. The LCD will show the following segments:
CUSTOMER SERVICE: 1-800-887-4321
23
TEMPUR-Ergo Premier
™
Flat (7)
Recall a memory position (8-9)
Press the FLAT button (7) and the bed
Press one of the Memory 1 to
Memory 4 buttons (8-9), for less
frame will automatically move to its
complete flat position. The LCD will show the
following segments:
than 3 seconds. The base will
move to the corresponding memory position.
The LCD will show the following segments, by
pressing the button Memory 1, button (8):
NOTE: Ensure all obstructions are clear of the
base’s undercarriage when lifting or lowering
the base’s head and leg sections to avoid risk
of pinching or damage.
NOTE: When the new position of the head is
NOTE: When the movement to the flat position
first the head section and then the leg section
is active it is possible to interrupt the movement
with any of the movement buttons 3-9, at any
time during movement for safety reasons.
higher than the current position of the head,
move to the corresponding memory position.
NOTE: If the new position of the head is equal
or lower than the current position of the head,
MEMORY
first the leg section and then the head section
Store a memory position (8-9)
move to the corresponding memory position.
The system is able to store up
NOTE: When the movement to a memory
to four (4) memory positions
position is active it is possible to interrupt the
Memory 1 to Memory 4.
First, move the head and leg sections to the desired
position. Then press one of the Memory 1 to
movement with any of the movement buttons
3-9, at any time during movement for safety
reasons.
Memory 4 buttons (8-9) for more than 3 seconds.
The corresponding memory position will be stored.
After a position has been stored, the backlight and
the LED signature light on the remote flash three
times.
The following segments are flashing on the LCD:
CUSTOMER SERVICE: 1-800-887-4321
24
Operation
MANUAL MASSAGE
Lower back massage (12-13)
The bed frame is equipped with three (3)
Press the LUMBAR Massage Intensity + button
massage motors (head, lumbar and leg).
(12), the lower back massage switches on at 10%
The system offers manual massage
intensity.
and four (4) predefined massage modes.
The corresponding level of the intensity of the
massage is shown on the display (L0 to L10).
NOTE: Once a massage is switched on it
automatically switches off completely after
30 minutes or when the STOP button on the
remote control is pressed.
Press the +/- buttons (12-13) to adjust the intensity
accordingly. The following segments are flashing on
the LCD:
NOTE: Whenever any massage function is on
and the user operates one of the lift buttons,
the massage switches off as long as the base
is moving. After the movement is finished, the
massage switches on with the same settings it
Leg massage (14-15)
had before the stop.
NOTE: Each massage zone is adjustable in
10% increments.
Press the LEG Massage Intensity + button (14),
the leg massage switches on at 10% intensity.
The corresponding level of the intensity of the
NOTE: Whenever the massage motor is on
and the manual massage button “+” or “–” is
pressed, the massage motor intensity increases
or decreases by one level. This can be repeated
until the intensity reaches the maximum or
massage is shown on the display (L0 to L10).
Press the +/- buttons (14-15) to adjust the intensity
accordingly. The following segments are flashing
on the LCD:
minimum value.
Head massage (10-11)
Press the HEAD Massage Intensity + button (10),
the head massage switches on at 10% intensity.
The corresponding level of the intensity of the
massage is shown on the display (L0 to L10).
MASSAGE MODES
A massage mode is a program
Press the +/- buttons (10-11) to adjust the intensity
which changes intensity and
accordingly. The following segments are flashing on
speed of one or more massage
the LCD:
zones. In doing so, each of the massage motors
runs automatically through a predefined sequence.
THE SYSTEM OFFERS THE FOLLOWING FOUR (4)
PREDEFINED MASSAGE MODES:
• Constant
• Simultaneous Wave
• Wave
• Pulse
CUSTOMER SERVICE: 1-800-887-4321
25
TEMPUR-Ergo Premier
™
The intensity of each motor zone can be changed
Massage Program 3: Simultaneous Wave (19)
while the program is running.
In this massage mode all three massage motors
Press one of the Massage buttons (Head Massage
simultaneously follow a wave.
+/- (10-11), Lumbar Massage +/- (12-13) or
Leg Massage +/- (14-15), the intensity of the
corresponding massage motor will change.
Press Massage Mode 3 button (19), and massage
mode 3 will start at 50% intensity at all three motors.
The LCD will show the following segments:
NOTE: If you change the massage mode
or change from massage mode to manual
massage, it will take approximately 2 seconds
before the new massage program will start.
Massage Program 1: Constant (17)
Massage Program 4: Pulse (20)
In this massage mode all three massage motors run
In this massage mode the three massage motors
at a constant intensity.
are switched on one after another in a pulse.
Press Massage Mode 1 button (17), and massage
Press Massage Mode 4 button (20), and massage
mode 1 will start at 50% intensity at all three motors.
mode 4 will start at 50% intensity at all three motors.
The LCD will show the following segments:
The LCD will show the following segments:
Massage Program 2: Wave (18)
STOP MASSAGE
In this massage mode the three massage motors
Press the Stop Massage button (16), all
are switched on one after another in a wave.
massage motors stop running. The LCD
Press Massage Mode 2 button (18), and massage
will show the following segments:
mode 2 will start at 50% intensity at all three motors.
The LCD will show the following segments:
CUSTOMER SERVICE: 1-800-887-4321
26
Operation
TEMPUR-Ergo Smart Control Operating Instructions
™
Once your Wi-Fi Module is installed, you can operate
SAVING AND RECALLING MEMORY POSITIONS
your bed from your smartphone or tablet. This section
To save a position on the
identifies all of the adjustments and settings you can
bed, tap and hold one of
control from your device.
the numbered memory
positions for 3 seconds.
To recall a memory
position, tap the numbered
memory button.
USING MASSAGE FEATURES
Tap and slide* the +/button for the Head,
Lumbar, or Leg to adjust
the massage intensity.
When the massage motor
is in operation, the text
below the slider, which
indicates the active zone,
is green.
Tap one of these buttons
to select the desired
massage mode.
* SLIDERS ARE THE DEFAULT SETTING. IF YOU
PREFER PUSH BUTTONS, YOU MAY SELECT THIS
OPTION IN THE APP SETTINGS.
Tap the STOP button to
USING THE HEAD AND FOOT LIFT CONTROLS
stop the massage.
Tap and slide the +/button for either the Head
or Leg sliders until the
desired height is reached.
Press the FLAT button
and the bed frame
automatically moves to its
*NOTE: Sliders are the default setting. If you
prefer push buttons, you may select this option
in the App settings.
complete flat position.
CUSTOMER SERVICE: 1-800-887-4321
27
TEMPUR-Ergo Premier
™
Advanced Remote Control Programming
The control box and the wireless remote control need
to be able to communicate via different RF channel
numbers in order to avoid interference with other
wireless remote controls or other remote control
equipment used near the system.
For this case the system offers ways to set up or
change the RF channel number.
LEARN PROCEDURE – WITH RF CHANNEL NUMBER
CHANGE (HOME MODE)
STEP 3
Press one of the massage buttons (10-15), (17-20)
to select a new random RF channel number. The
LCD shows the new random RF channel number on
the display.
STEP 4
Press the FLAT button (7) to confirm the
RF channel number and the wireless
remote control sends its current RF channel number
for 30 seconds. The LED signature light and the
This channel setup procedure changes the
backlight of the buttons are flashing during this time.
RF channel number from the factory setting.
During this time also the LCD still shows the
The new RF channel number will be chosen
RF channel number.
automatically by the system.
STEP 5
NOTE: Use this procedure to avoid interference
Re-connect the power cord (G) to the wall outlet
with other wireless remote controls or other
within 30 seconds of step 4.
remote control equipment (e.g. remote
controlled toys, garage door openers…)
You will hear two “double-clicks”. Then press the
which are used near the system.
STOP button.
NOTE: If the 30 seconds of RF channel number
STEP 1
Disconnect the power cord (G) from wall outlet.
transmission expire before the system is reconnected to the power, the control box and the
wireless remote control will not work together.
STEP 2
Press and hold both FLAT button (7) and
STOP button (16) for at least 10 seconds.
The current RF channel number will be
shown on the display (e.g. “2875”) for
10 seconds.
In this case the procedure must be repeated.
NOTE: If the new RF channel number is not
confirmed with the FLAT button, the RF channel
number will remain unchanged and the steps
must be repeated.
CUSTOMER SERVICE: 1-800-887-4321
28
Advanced Remote Control Programming
LEARN PROCEDURE – WITH RF CHANNEL NUMBER
CHANGE (SHOWROOM MODE)
STEP 5
Press the FLAT button to confirm the RF channel
number. The RF channel number will flash for 30 seconds.
In contrast to the home mode, the RF channel number
can be chosen yourself.
The LCD will show the following segments for example:
The advantage of this procedure is that you can use up
to eight systems in one showroom without interrupting
each other.
The following steps must be performed:
STEP 1
NOTE: The first part of the RF channel number
selects a specific frequency range whereas the
Disconnect the power cord (G) from wall outlet.
STEP 2
Press and hold both FLAT button (7) and
STOP button (16) for at least 10 seconds.
The current RF channel number will be
second part selects a RF channel number within
that frequency range. The showroom mode
allows up to 64 different RF channel numbers.
NOTE: In showrooms, when several bases
will operate simultaneously, it is required that
the first digit of the RF channel be unique (e.g.
RF channel number “12” can be used at the
same time as “22” or “32”, but not necessarily
at the same time with “13” or “15” etc.)
shown on the display (e.g. “2875”) for
10 seconds.
STEP 6
Re-connect the power cord (G) to the wall outlet within
30 seconds of step 5. You will hear two “double-clicks”.
STEP 3
Then press the STOP button.
Press one of the memory buttons (1-4) or one of
the manual movement buttons (5-8) to select the
first part of the RF channel
number. Select a unique
number for each base.
The LCD shows the first
selection as a number,
from 1 to 8, for 10 seconds.
5
7
6
8
1
4
2
3
NOTE: If the 30 seconds of RF-channel number
transmission expire before the system is reconnected to the power, the control box and the
wireless remote control will not work together.
In this case the procedure must be repeated.
The RF channel number which will be shown
depends on the pressed button.
STEP 4
Press one of the memory buttons (1-4) or one of
the manual movement buttons (5-8) to select the
second part of the RF channel number. The LCD
shows the second part of the selection, as 1 to 8,
for 10 seconds (the RF channel number which will
be shown depends on the pressed button).
CUSTOMER SERVICE: 1-800-887-4321
29
TEMPUR-Ergo Premier
™
Special Functions
SYSTEM RESET
TANDEM OPERATION
This function resets the system to the zero position.
A reset is required in following cases:
• One of the components is removed
• The bases don’t work synchronously in tandem
operation
Each base must be moved to the flat position
separately by following the single system
instructions.
After this procedure the two (2) 9-Volt batteries
of both power supplies must be changed.
• After a power outage (only for tandem operation)
Once power returns the user must perform a system
• System error
reset to connect both systems with each other (see
System Reset on page 30).
RESET PROCEDURE
NOTE: After emergency power-down in a
Press and hold the FLAT button (7).
After 15 seconds, the LCD changes from FLAT to
tandem system, a system reset must be
performed (see System Reset on page 30).
RST - do not release the FLAT button! Continue
holding the FLAT button for an additional 30-60
seconds as the bed moves forward and backward.
The reset process is complete when no audible clicks
or movement occurs for a minimum of 10 seconds.
Change from a Tandem
System to a Single System
STEP 1
Emergency Power-Down
The power-down button on the power supply gives the
user the possibility to move the bed to a flat position
during power failure.
Disconnect both bases from wall outlet.
STEP 2
Remove connection cable from each control box.
STEP 3
Learn Remote 1 to Base 1 following Learn
Procedure on page 28.
SINGLE SYSTEM
Press the power-down button on the power supply
until the bed arrives at the flat position. After this
procedure the two (2) 9-Volt batteries must be
changed.
DANGER: Risk of pinching!
STEP 4
Perform System Reset on page 30 for Remote 1
and Base 1.
STEP 5
Repeat steps 3-4 using Remote 2 and Base 2.
NOTE: During the emergency power-down
procedure the lowering speed will be reduced.
NOTE: Do not mix old and new batteries.
CUSTOMER SERVICE: 1-800-887-4321
30
Special Functions
Using Factory Reset for the Wi-Fi Module
STEP 3
Tap Reset to Factory Settings.
Apple® iOS device
Android™ device
If you have your Wi-Fi Module integrated into your
Home Network and want to make the Wi-Fi Module
directly accessible again via its own Wi-Fi network,
you must first perform a Factory Reset to reset the
Wi-Fi Module.
PERFORM A RESET ON THE HARDWARE
Press and hold the button on the Wi-Fi Module for
approximately 5 seconds.
STEP 4
Tap OK.
PERFORM A RESET ON THE APP
Apple® iOS device
You can only perform a reset on your App if the Wi-Fi
Module is integrated into your Home Network and there
is an active connection to it. To perform a reset, follow
these instructions:
STEP 1
Tap the Settings screen icon
on the
TEMPUR-Ergo™ Smart Control App screen.
Android™ device
STEP 2
Select the corresponding Wi-Fi Module by tapping
either the
or the
on your Apple® iOS or
Android™ device, respectively.
CUSTOMER SERVICE: 1-800-887-4321
31
TEMPUR-Ergo Premier
™
Troubleshooting
In the event that your TEMPUR-Ergo™ Premier fails to operate properly, investigate the symptoms and possible
solutions provided in the chart below:
SYMPTOM
SOLUTION
Wireless Remote Control LED Signature
Light illuminates and appears to be
operable but will not activate the
TEMPUR‑Ergo Premier.
• Verify that the power cord is plugged into a working, grounded
electrical outlet. A grounded, electrical surge protection device
is recommended. Test the outlet by plugging in another working
appliance.
• Verify that the power cord is plugged into power supply.
• Verify the control box is learned to the remote by following the
Setup Procedure on page 14.
• Verify the green LED light on the power supply is lit – if not the
unit is not receiving power.
• Program the Wireless Remote Control (see the
Wireless Remote Control Guide, included with this product, for
programming procedures). Make certain the Power Down Box is
easily accessible. Relocate the Power Down Box if necessary.
No features of the
TEMPUR-Ergo Premier will activate.
• Unplug the power cord, wait 60 seconds and plug the power
cord back in to reset the electronic components.
• Your surge protection device and/or electrical circuit breaker
may be tripped. Check both to verify.
• Your surge protection device and/or electrical outlet may
be defective. Test the outlet by plugging in another working
appliance.
Wireless Remote Control LED Signature
Light will not illuminate.
• Replace the batteries in the Wireless Remote Control. The unit
requires two (2) AA batteries.
NOTE: Do not mix old and new batteries.
• Ensure the batteries are installed correctly.
• The TEMPUR‑Ergo Premier may be obstructed. Elevate and
check for an obstruction. Remove the obstruction.
Head and/or Leg section will elevate
but will not return to the horizontal (Flat)
position.
• The head section may be too close to the wall.
• The headboard may be too close to the edge of the mattress.
Verify that a 1.5" (38.1mm) to 2" (50.8 mm) distance is between
the headboard brackets and the mattress. Adjust if required.
CUSTOMER SERVICE: 1-800-887-4321
32
Troubleshooting
SYMPTOM
SOLUTION
• Check batteries in Wireless Remote Control, replace with two (2)
new AA batteries if necessary.
NOTE: Do not mix old and new batteries.
Head and/or Leg lift function has minor
interference during operation.
• Make sure that you are following the duty cycle of the motors
(do not operate more than 2 minutes over a 20-minute period,
or approximately 10% duty cycle).
• Press the lift buttons squarely and accurately.
• Wireless Remote Control may be experiencing common Radio
Frequency Interference from other radio transmitting devices.
Wait several seconds, and then try pressing appropriate button
again. See FCC Compliance Statement on page 6 of this
guide.
• If the bed is located on hard surface flooring, place carpet
pieces or rubber pieces (not included) under each leg or caster
of your TEMPUR‑Ergo™ Premier.
• Using the Wireless Remote Control, elevate the head or leg
section a short distance to realign the lift/lower mechanisms
with the bed support platform.
Excessive massage motor noise.
• Verify that your TEMPUR‑Ergo Premier is not positioned against
a wall, night stand, or other object that may cause the vibration
or noise.
• If the TEMPUR‑Ergo Premier is installed over a bed frame,
verify that the massage motors are not causing the bed frame
(or bed frame components) to vibrate.
• Verify that the headboard attachment hardware is properly
tightened (if used).
A clicking noise is heard under the bed
when raising or lowering.
• This is normal. The lift motor relays “click” when they are
engaged. No action is required.
Massage motor overheats or stops.
• If the vibration motor overheats, the thermal protection will
turn the motor off. Wait 30 minutes, turn the massage back on.
If it does not come on, turn it off and report the situation
to customer service.
CUSTOMER SERVICE: 1-800-887-4321
33
TEMPUR-Ergo Premier
™
SYMPTOM
SOLUTION
• Ensure the smart device is not set to a static IP address.
• Ensure the adjustable base and Wi-Fi Module is in close
proximity to your smart device so it can receive a strong signal.
Unable to connect to the Wi-Fi Module
in direct mode.
• Ensure there is not a high level of wireless network traffic.
Multiple networks in the same area, or streaming of audio and
video can clutter up a network and interfere with proper signal
reception.
• If using a tandem bed system (two adjustable bases),
ensure you are connected to the primary bed’s Wi-Fi Module.
This may require connecting to both modules to determine
which is controlling the system.
• Ensure the router is powered on and functional.
• Be sure you entered the login data correctly (network name,
password, type of security) in order to connect your Wi-Fi
Module to your home network router.
• Be sure that the IP settings of the wireless router, smart device,
and Wi-Fi Module are compatible with one another.
• If not using expert mode on the smart device’s app, be sure that
DHCP is active on the router.
• Be sure that your router does not use WEP encryption, which is
outdated and unsupported.
Cannot use the system in the home
network mode.
• Be sure that UDP Port 50007 and TCP Port 2000 are not
blocked on your router.
• Ensure that the bed is in close proximity to the router,
preferably in the same room or next room, and not on a
different floor of the home.
• Ensure that the smart device is receiving strong signal from the
home network wireless router.
• Ensure that no other smart device is operating the same bed at
the same time.
• Ensure that high network traffic on your wireless network isn’t
influencing the Wi-Fi connection. A high number of connected
devices, or audio and video streaming are common examples.
Cannot access the Internet on my
smart device while connected to the
Wi-Fi Module.
Your smart device can only connect to one network at a time.
®
If you would like to use the Tempur-Pedic App and surf the
Internet, integrate the Wi-Fi Module into the home network
following the instructions in the owner’s manual.
CUSTOMER SERVICE: 1-800-887-4321
34
Troubleshooting
SYMPTOM
SOLUTION
Unable to control the adjustable base
with my smart device after changing my
router settings or password.
The settings in the app will have to be updated to accommodate
the change to your home network. Perform a factory reset on the
Wi-Fi Module by pressing the button on the module until the red
LED lights up and then releasing the button. Go through the home
network setup again, this time using the new settings.
Unable to correct my password/
network name/encryption mode.
Perform a factory reset on the Wi-Fi Module by pressing the button
on the module until the red LED lights up and then releasing the
button. Go through the home network setup again, this time using
the correct settings.
• Ensure that your router is compatible with the Wi-Fi Module
(review the question “supported routers”).
Unable to use my home network even
though the settings are all correct.
• The character “^” must not be used in the network name (SSID)
or encryption password.
• WEP security is not supported by the Wi-Fi Module – select
another type of security supported by the Wi-Fi Module (see
question “Which wireless routers are supported?”).
If the app doesn’t find a Wi-Fi Module to connect to, it may be in
Demo Mode. Close the app, connect the smart device to the Wi-Fi
Module in your device’s Wi-Fi settings menu and start the app
again.
App does not work from my
smart device.
Unable to install the app on my
smart device.
Unable to get my new router to work
with my smart device to control the
adjustable base.
• Ensure that your Internet connection and your restrictions/
settings on the smart device allow downloading and installation
of apps from the App Store, Play Store, or Amazon.
• Be sure to use a supported device, listed in the supported
devices section.
The settings in the app will have to be updated to accommodate
the change to your home network. Perform a factory reset on the
Wi-Fi Module by pressing the button on the module until the red
LED lights up and then releasing the button. Go through the home
network setup again, this time using the new settings.
CUSTOMER SERVICE: 1-800-887-4321
35
TEMPUR-Ergo Premier
™
Date of Manufacture:
Serial Number:
FOR TECHNICAL SUPPORT OR SERVICE,
QUESTIONS ABOUT YOUR TEMPUR-PEDIC® MATTRESS,
OR TO ORDER TEMPUR‑ERGO™ PREMIER ACCESSORIES:
1-800-887-4321
OR VISIT WWW.TEMPURPEDIC.CA
CUSTOMER SERVICE: 1-800-887-4321
36
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising