Manual UTP (Ethernet) connection ICU charging station

You are in possession of an intelligent ICU charging station that can communicate with a back office system through an internet cable. Your charging station is configured to connect to a network directly. Through the back office system of the charging station, it is possible to view the energy consumption and offer remote control.

Which cable is required to connect the charging station?

Figure 1:

UTP cable

A UTP cable of minimally CAT5 is needed to connect the charging station to the Internet. This cable is suitable for speeds up to 100Mbps.

Installation

1. Connect the UTP cable to your router;

2. Turn off the power of the charging station by putting the main switch to the zero (0) position;

3. Connect the UTP cable to the Communication Unit of the charging station. See Figure 2 for the ICU Compact and Figure 3 for the ICU

Eve;

UTP port

Image 2: ICU Compact

UTP port

Image 3: ICU EVe

4. Turn on the power of the charging station by putting the main switch to the 1 position;

5. Register your ICU EZ account.

Registering your ICU EZ account

Step 1

Go to www.icu-charging-stations.com/ez-english . Fill out the digital form and click 'Send'.

Step 2

ICU will process the form and activate your account. Your login details will be sent to you as soon as possible.

Step 3

You can login to the website www.icu-ez.com with your received account information.

Step 4

After logging on to ICU EZ you can see if your charging station is online. This will be shown with the status "Available". If your charging station is not yet connected, it will show the status 'Planned' (see Fig. 4).

2

Figure 4

Is your charging station ON and is the UTP cable connected properly? Then proceed to the next step.

Step 5

In order for your charging station to communicate with ICU EZ through a wired

UTP ethernet connection, your network setting should be adjusted if these are additionally secured. Below you will find the necessary information to allow access through your network.

IP address ICU EZ: 93.191.128.6;

Port: 9090;

Inbound

– Outbound.

It may be possible that a MAC address is required, this is stated on the FAT report of the charging station. This report can be provided by ICU.

Please note

In the unlikely case of a failure of the charging station, please contact the reseller from which the product has been purchased.

3