1 2 3 4 5 6 7 8 9 10 A 12 13 14 - Honeywell

1 2 3 4 5 6 7 8 9 10 A 12 13 14 - Honeywell
1
General Information
2
Actuators
3
Valves linear
4
Valves rotary
5
Frequency inverters
6
Sensors
7
LON field devices
8
Thermostats
9
Pneumatic Products
10
Miscellaneous
A
Applications and Dimensioning
12
13
Honeywell Field Devices on the Internet
- interactive and with documentation download.
http://europe.hbc.honeywell.com
14
Index of product series
1
2
3
4
5
6
7
8
9
10
11
12
13
Product series
Page
2-way linear valves, stroke 2,5/6,5mm
2-way linear valves, stroke 20/38mm
3-way linear valves, stroke 2,5/6,5mm
3-way linear valves, stroke 20/38mm
Actuators, LON
3-2
3-10
3-20
3-32
7-2
Air quality sensors
Butterfly valves
Controllers, pneumatic
Damper actuators
Damper/Valve Actuators, pneumatic
6-38
4-2
9-2
2-19
9-3
Frequency inverters
Frost protection
General Information
Heat meters
Humidistats
5-2
8-2
1-2
10-2
10-6
IRC/XL10 sensors, Wall modules
Large linear actuators, stroke 20/38mm
LON linear actuators
Miscellaneous
Overview: Large linear actuators
Overview: Rotary valve actuators
Overview: Small linear actuators
Pneumatic Electrical
Pressure sensors
Pressure switches
Relays, pneumatic
R.H. ( + temperature) sensors
Room thermostats
Rotary valve actuators
Rotary valves
Safety thermostats
Sensors, pneumatic
Signal modules
Small linear actuators, stroke 2,5/6,5mm
Switches
6-18
2-10
2-14
6-40, 9-13
2-9
2-16
2-2
9-8
6-30, 7-6
6-22
9-5
6-16
8-9
2-17
4-6
8-4
9-9
10-11
2-3
10-8
Temperature sensors, LON
Temperature sensors Balco
Temperature sensors NTC 20 kohm
Temperature sensors Pt1000
Thermostat/Humidistat
7-4
6-14
6-3
6-9
9-10
Transformers
10-9
14
0-0
http://europe.hbc.honeywell.com
Index of product groups
Product group
Page
1
2-14, 7-2
2-8
2-7
2-11
2-13
2
A
Actuator + PI-controller LON for radiator valves/zone control, 2,5/6,5 mm 90/180/300 N, M7410G
Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435
Actuator 0/2..10V for zone control, 6,5 mm 180/300 N, M7410E
Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425
Actuator 0/2..10V, 20/38 mm 1800 N, ML7421
2-8
2-4
2-6
2-10
2-12
3
Actuator LON, 20 mm 600 N, ML7420G
Actuator thermoelectric 0..10V for terminal unit/radiator valves, 2,5 mm 90 N, MT010
Actuator thermoelectric for terminal unit/radiator valves, 2,5 mm 90 N, M100/Z100
Actuator thermoelectric for zone control, 6,5 mm 90 N, M4450/M8450
Air duct humidistat
2-15, 7-3
2-4
2-3
2-5
10-7
4
Air duct R.H.- and temperature sensor
Air duct temperature sensor NTC, LON
Air duct temperature sensor PTC, active
Air duct temperature sensor, average measurement
Air duct temperature sensor, Balco
6-17
7-5
6-41
6-7, 6-13
6-15
Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435
Actuator 3-pt for terminal unit/radiator valves, 2,5 mm 90 N, M7410A
Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410
Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Actuator 3-pt, 20/38 mm 1800 N, ML6421
Air duct temperature sensor, NTC
Air duct temperature sensor, PT100
Air duct temperature sensor, PTC
Air quality sensor
6-7
6-40
6-12
6-38
5
6
7
B
Butterfly valve DN25..200, without actuator
4-3
8
C
CO2 air quality and temperature sensor
Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Compact Line Rotary Valve Actuator
Conversion module 0..10Vdc/relay, 3 channel
Conversion module 24Vdc/relay
6-39
3-8
2-17
10-12
10-11
9
D
Damper actuator 10/20 Nm, SmartAct springreturn
Damper actuator 16 Nm spring return
Damper actuator 20/34 Nm, SmartAct
Damper actuator 5/10 Nm
Damper actuator 5/10 Nm, SmartAct
2-22
2-23
2-21
2-20
2-19
Damp-proof temperature sensor, NTC
Dew-point sensor
Differential pressure switch for air
Differential pressure switch for liquids and gases
Differential pressure transmitter for air
6-8
6-44
6-25
6-24
6-34
Differential pressure transmitter for liquids and gases, LON
Differential/over- pressure transmitter for non-aggressive gases, LON
Double range differential pressure transmitter for air
7-6
7-7
6-36
E
Earth temperature sensor, NTC
Electrical power/energy meter, EE7003
Electric-pneumatic relay
Electric-pneumatic signal conversion module
Electronic flow switches for liquid, compact version
6-8
10-5
9-5
9-8
6-43
Electronic Pressure switch for gases and low viscosity liquids, SmartPress
Electronic Pressure switch for liquides with high viscosity or roiled liquids, SmartPress
Electronical air flow switch for air
6-32
6-30
6-41
0-1
10
11
12
13
14
Index of product groups
1
Product group
Electronical flow switch for liquid
Enclosed Transformer
2
3
4
6
6-42
10-10
F
Fast motoric actuator for terminal unit/radiator valves, 2,5/6,5 mm 90 N, M5410
Flue gas temperature sensor, PTC
Flue gas thermostat
Four-way rotary valve PN6
Four-way rotary valve PN6, compact
2-5
6-13
8-8
4-10
4-11
Four-way rotary valve PN6, compact, corrosion protected
Frost protection thermostat for duct mounting, 2 phases
Frost protection thermostat with capillary
4-12
8-3
8-2
G
Goldcontact relays
5
Page
10-13
I
Inverters 1,1..110kW, IP21, NXS
Inverters 1,1..110kW, IP54, NXS
Inverters economy 0,5..2,2kW, IP20, NXL
Inverters economy 1,1..30kW, IP21/IP54, NXL
Isolating relay
5-4
5-5
5-2
5-2
10-13
M
7
8
9
Manual positioning module
Manually operated Butterfly valve
Maximum pressure limiter of 'special construction'
Minimum pressure limiter for hot water, steam, fuel, gas.
Motorized Butterfly valve DN250..600
10-12
4-2
6-29
6-28
4-4
O
Outdoor R.H.- and temperature sensor
Outdoor temperature sensor NTC
Outdoor temperature sensor, Balco
Outdoor temperature sensor, PTC
Outdoor, strap-on temperature sensor, NTC
6-17
6-7
6-15
6-12
6-6
Outdoor, strap-on temperature sensor, PTC
6-12
P
10
11
12
13
14
Paddle flow switches for air
Paddle flow switches for liquid
Pneumatic Capacity Relay
Pneumatic damper actuator with shaft connection, MP913
Pneumatic damper actuator, MP904
6-42
6-43
9-6
9-3
9-3
Pneumatic electrical relay
Pneumatic Ratio Relay
Pneumatic Reversing Relay
Pneumatic room humidity controller, HP970
Pneumatic room humidity sensor, HP971
9-8
9-7
9-7
9-12
9-12
Pneumatic room temperature controller, TP937/938
Pneumatic room temperature controller, TP970
Pneumatic room temperature sensor, TP974
Pneumatic selector relay, RP470
Pneumatic Sensor Controller System
9-10
9-11
9-11
9-5
9-2
Pneumatic snap action relay, RP471
Pneumatic switches, SP470/970
Pneumatic switching relay, RP670
Pneumatic temperature sensor, LP914
Pneumatic temperature sensor, LP915
9-5
9-13
9-6
9-9
9-9
Pneumatic unit-temperature controller, TP939/940
Pneumatic valve actuator, MP953
9-10
9-4
0-2
http://europe.hbc.honeywell.com
Index of product groups
Product group
Pressure monitor for hot water, steam, burnable gases and liquid fuels
Pressure reducing valve with Filter Regulator Station, PP907
Pressure switch for non-aggressive liquids and gases
Pressure transmitter for liquids and gases, LON
Page
6-26
9-13
6-22
7-8
1
2
R
Relay module for on/off and 3-pt control
Relay module for on/off control
Remote setpoint adjustment unit for IRC or XL10
Room and air duct humidistats
Room CO2 sensor
Room humidistat
Room humidistat, low voltage
Room R.H.- and temperature sensor
Room temperature sensor NTC, economy
Room temperature sensor NTC, LON
Room temperature sensor, NTC
Room temperature sensor, Pt100
Room temperature sensor, setpoint unit
Room temperature sensor, setpoint unit, IRC style
Room temperature/ CO2 sensor
Room thermostat for industrial permises
Room thermostat, corrosion resistive
Room thermostat, industrial, 1/2 stages
10-11
10-13
6-19
10-6
6-38
10-6
10-7
6-16
6-3
7-4
6-3, 6-4
6-40
6-9, 6-14
6-4, 6-18
6-39
8-10
8-9
8-9
S
Safety limiting thermostat with setpoint knob, and shut-off
Safety limiting thermostat with setpoint knob, and shut-off, automatic reset
Safety limiting thermostat, automatic reset
Safety limiting thermostat, hand reset, large temperature range
Safety limiting thermostat, with hand reset
Safety limiting thermostat, with shut-off
Signal separator, 4 channel
Solar sensor
Standard Line Rotary Valve Actuator
Status display module, 4 channel
Switching module, Q6371
8-5
8-6
8-8
8-4
8-4
8-7
10-13
6-40
2-18
10-12
4
5
6
7
8
9
10-8
10
T
Three-way control valve PN16, conical sealing DN15/20, V5823A
Three-way control valve PN16, flanged connections DN 15-150, V5329A/V5050A,B
Three-way control valve PN16, flat sealing DN15/20, V5833A
Three-way control valve PN16, flat sealing DN15-50, V5013E
Three-way control valve PN16, flat sealing DN25-40, V5833A
3-22
3-38
3-26
3-32
3-30
Three-way control valve PN16, threaded connections DN15-50, V5013R
Three-way control valve PN16, threaded connections DN15-50, V5078B
Three-way control valve PN25/40, flanged connections DN15-100, V5050A,B
Three-way control valve PN6, flanged connections DN15-150, V5329C/V5015A
Three-way rotary valve PN10
3-34
3-20
3-40
3-36
4-12
Three-way rotary valve PN6
Three-way rotary valve PN6, compact
Three-way rotary valve PN6, compact, corrosion protected
Three-way/bypass control valve PN16, conical sealing DN15/20, V5823C
Three-way/bypass control valve PN16, flat sealing DN15/20, V5833C
4-6
4-8
4-9
3-24
3-28
Transformer
Transformer wall mounting
Transformer, 2 secondary windings
Two-way control valve PN16, conical sealing DN15/20, V5822A
Two-way control valve PN16, flanged connections DN15-150, V5328A/V5049A
3
10-9
10-10
10-9
3-2
3-12
0-3
11
12
13
14
Index of product groups
1
2
3
Product group
Page
Two-way control valve PN16, flat sealing DN15/20, V5832A
Two-way control valve PN16, flat sealing DN25-40, V5832B
Two-way control valve PN16, high differential pressure DN15-150, V5016A
Two-way control valve PN16, threaded connections DN15-50, V5011R,S
Two-way control valve PN25, high differential pressure DN15-150, V5025A
3-4
3-6
3-14
3-10
3-16
Two-way control valve PN40, flanged connections DN15-100, V5049A
3-18
U
Unit temperature sensor
6-8
V
4
Voltage level switch
10-11
W
5
6
7
8
Wall module with temperature and R.H. sensor
Wall modules for EXCEL 5000 controllers
Wall modules for EXCEL 5000 controllers, with display
Wall modules for heating applications
Water flow combi heatmeter, multi-jet EW110
6-16
6-20
6-21
6-3
10-3
Water flow combi heatmeter, single-jet EW100
Water flow combi heatmeter, ultrasonic EW300
Water flow combi heatmeter, Woltmann wheel, EW115
Water temperature sensor NTC, cable type
Water temperature sensor NTC, fast reaction time
10-2
10-5
10-4
6-6
6-6
Water temperature sensor NTC, LON
Water temperature sensor Pt1000, fast reaction time
Water temperature sensor PTC, cable type
Water temperature sensor PTC, strap-on
Water temperature sensor, Balco
7-4
6-11
6-11
6-10
6-14
Water temperature sensor, NTC
Water temperature sensor, PTC
Water temperature sensors NTC, fast reaction time,LON
6-5
6-10
7-5
9
10
11
12
13
14
0-4
http://europe.hbc.honeywell.com
Index of products
Type
Page
0
075041061
0903403
2-17
2-6, 3-20
1
14003030-001
14004406-110
14004406-120
9-6, 9-7
9-11
9-11
14004406-124
9-12
4
Type
Page
Type
Page
ACN-15S
ACN-15T
ACN-20C
ACN-20S
ACN-20T
3-2, 3-22, 3-24
3-2, 3-22, 3-24
3-2, 3-22, 3-24
3-2, 3-22, 3-24
3-2, 3-22, 3-24
DCM06
DCM1
DCM10
DCM16
DCM25
6-23
6-23
6-23
6-23
6-23
ACS-15T
ACS-15W
ACS-20T
ACS-20W
ACS-25T
3-8
3-8
3-8
3-8
3-8
DCM3
DCM40
DCM6
DCM625
DCM63
6-23
6-23
6-23
6-23
6-23
ACS-25W
ACS-32T
ACS-32W
AF20
AFF-L
3-8
3-8
3-8
6-7
7-4
DCMV025
DCMV06
DCMV1
DCMV10
DCMV16
6-23
6-23
6-23
6-23
6-23
AGF1
AK15-15
AK20-15
AK20-25
AK25-25
6-13
3-8
3-8
3-8
3-8
DCMV25
DCMV3
DCMV40
DCMV6
DCMV63
6-23
6-23
6-23
6-23
6-23
AQS3/4CABLE
AQS51
AQS51-KAM
AQS61
AQS61-KAM
6-39
6-39
6-39
6-39
6-39
DDCM014
DDCM1
DDCM16
DDCM1602
DDCM252
6-24
6-24
6-24
6-24
6-24
43161276-001
43163162-001
43163162-002
9-4
9-9
9-9
43191430-001
43191679-001
43191679-002
43191679-007
43191679-008
9-4
2-12
2-12
2-12
2-12
43191679-011
43191679-012
43191680-002
43191680-005
43196000-001
2-10, 2-11
2-10, 2-11
2-12, 2-13
2-10, 2-11, 2-15, 7-3
2-10, 2-11, 2-12, 2-13, 2-15, 7-3
AQS-F0005
AQSPC
ASL453
ASL453/24
ASW454
6-39
6-39
6-41
6-41
6-42
DDCM4
DDCM6
DDCM6002
DDCM662
DGF20
6-24
6-24
6-24
6-24
6-8
43196000-002
43196000-038
43297431-001
2-10, 2-11, 2-12, 2-13, 2-15, 7-3
2-12, 2-13
9-4
ASW454/24
6-42
DKF20
DNM025
DPS1000
DPS200
DPS2500
6-6
6-23
6-25
6-25
6-25
A
C
A7116.0050
A7209.2071
A7209.2072
2-20, 4-8, 4-9, 4-11, 4-12
2-21
2-21
C7068A1007
C7068A1007-5M
C7085A1006
A7209.2073
AC-15FS
AC-15FT
AC-15TF
AC-20FS
2-21
3-4, 3-26, 3-28
3-4, 3-26, 3-28
3-32
3-4, 3-26, 3-28
C7085A1014
C7110A1005
C7110C1001
C7110D1009
CRE1
AC-20FT
AC-20TF
AC-25T
AC-25TF
AC-32T
3-4, 3-26, 3-28
3-32
3-6, 3-30
3-6, 3-30, 3-32
3-6, 3-30
CRT12
CRT2
CRT6
CRT6/12
CRT6/6
AC-32TF
AC-40T
AC-40TF
AC-50TF
ACN-15C
3-6, 3-30, 3-32
3-6, 3-30
3-6, 3-30, 3-32
3-32
3-2, 3-22, 3-24
D
DAF20
DBZ-05
DCM025
6-8
6-8
6-13
DPS400
DPS500
DPSK
DPSL
DPT100
6-25
6-25
6-37
6-25, 6-37
6-36
6-7
6-38
6-38
6-39
10-13
DPT1000
DPT1000D
DPT1002
DPT1003
DPT1003D
6-36
6-36
6-37
6-37
6-37
10-9
10-9
10-9
10-9
10-9
DPT100D
DPT102
DPT103
DPT103D
DPT110
6-36
6-37
6-37
6-37
6-36
6-7
8-2
6-23
DPT112
DPT113
DPT250
DPT250D
DPT252
6-37
6-37
6-36
6-36
6-37
0-5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Index of products
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Type
Page
Type
Page
Type
Page
DPT253
DPT253D
DPT50
DPT500
DPT500D
6-37
6-37
6-36
6-36
6-36
EW110P1036
EW110P3529
EW110P6027
EW115A1539
EW115A2537
10-3
10-3
10-3
10-4
10-4
H7508A1042
HE25
HE32
HGK3
HP970A1009
6-17
4-13
4-13
10-7
9-12
DPT502
DPT503
DPT503D
DPT52
DPT53
6-37
6-37
6-37
6-37
6-37
EW115A4038
EW115A6033
EW115M1533
EW115M2531
EW115M4032
10-4
10-4
10-4
10-4
10-4
HP970B1007
HP970B1015
HP971A1008
HP971A1024
9-12
9-12
9-12
9-12
DRF20-S
DWR06
DWR06-203
DWR06-206
DWR1
6-3
6-27
6-27
6-28
6-27
EW115M6037
EW115P1536
EW115P2534
EW115P4035
EW115P6030
10-4
10-4
10-4
10-4
10-4
I
DWR1-203
DWR1-206
DWR16
DWR16-203
DWR16-206
6-27
6-28
6-27
6-27
6-28
EW300M1520
EW300M2528
EW300M6016
10-5
10-5
10-5
K
DWR25
DWR25-203
DWR25-206
DWR3
DWR3-203
6-27
6-27
6-28
6-27
6-27
F
FHBN10-355-L
FHBN1-355-L
FHBN3-355-L
7-6
7-6
7-6
DWR3-206
DWR40
DWR40-203
DWR40-206
DWR6
6-28
6-27
6-27
6-28
6-27
FHBN5-355-L
FTS015
FTSB015
7-6
8-3
8-3
DWR6-203
DWR6-206
DWR625
DWR625-203
DWR625-206
6-27
6-28
6-27
6-27
6-28
G
E
GF20
GT4
6-8
10-13
H
IRA-AD
2-4
KA10
KSW230
KSW24
10-13
6-43
6-43
KTF20
KTF20-B
6-6
6-6
L
L404F1219
L7087A1046
L7087A1053
9-8
6-15
6-14
L7087A1061
LF20
LF20-L
LF24
LP914A1151
6-15
6-7
7-5
6-41
9-9
9-9
9-9
9-9
9-9
9-9
EE7003A1008
EF20
ETR2
10-5
6-8
10-10
H12
H3
H600A1022
6-35
8-3
10-6
LP914A1169
LP914A1177
LP914A1193
LP914A1201
LP914A1235
EW100A1528
EW100A2526
EW100A6014
EW100M1522
EW100M2520
10-2
10-2
10-2
10-2
10-2
H6045A1002
H6120A1000
H615A2015
H615A2077
H7012A1009
10-6
10-6
10-7
10-7
6-16
LP915A1044
LSU25-18
LSU25-22
LSU25-28
LSU32-22
9-9
4-13
4-13
4-13
4-13
EW100M6018
EW100P1525
EW100P2523
EW100P6011
EW110A1039
10-2
10-2
10-2
10-2
10-3
H7012B1007
H7012B1015
H7012B1023
H7015A1006
H7015B1004
6-16
6-16
6-16
6-17
6-17
LSU32-28
LSU32-35
4-13
4-13
EW110A3522
EW110A6020
EW110M1033
EW110M3526
EW110M6024
10-3
10-3
10-3
10-3
10-3
H7015B1012
H7015B1020
H7018A1003
H7508A1026
H7508A1034
6-17
6-17
6-44
6-17
6-17
M
0-6
http://europe.hbc.honeywell.com
M100-AG
M100-AGE
M100-AGX
2-3
2-3
2-3
Index of products
Type
Page
Type
M100-AO
M100-AOX
M100-BG
M100-BGE
M100-BGX
2-3
2-3
2-3
2-3
2-3
MCE1
MCE2
MCE3
MCM1
MCP1
M100-BO
M100-BOX
M4450A1009
M5410C1001
M5410C4005
2-3
2-3
2-5
2-5
2-5
M5410L1001
M5410L1506
M5410L4005
M5410L4500
M6061A1013
Page
Type
Page
10-11
10-11
10-12
10-12
10-12
MP904D1040
MP904D1057
MP913B1068
MP913B1076
MP913C1066
9-3
9-3
9-3
9-3
9-3
ML4195E1002
ML4195E1010
ML6161E3011
ML6161E3029
ML6174E3014
2-23
2-23
2-20
2-20
2-20
MP913C1074
MP953A5005
MP953A5039
MP953A5054
MP953B5003
9-3
9-4
9-4
9-4
9-4
2-5
2-5
2-5
2-5
2-18
ML6174E3022
ML6420A3007
ML6420A3015
ML6420A3023
ML6420A3031
2-20
2-10
2-10
2-10
2-10
MP953C5001
MP953C5019
MP953C5027
MP953C5068
MP953C5076
9-4
9-4
9-4
9-4
9-4
M6061A1021
M6061A1039
M6061A1047
M6061L1019
M6061L1027
2-18
2-18
2-18
2-18
2-18
ML6420A3072
ML6421A3005
ML6421A3013
ML6421B3004
ML6421B3012
2-10
2-12
2-12
2-12
2-12
MP953C5084
MP953C5142
MP953C5159
MP953D5009
MP953D5025
9-4
9-4
9-4
9-4
9-4
M6061L1035
M6061L1043
M6063A1003
M6063A4007
M6063L1009
2-18
2-18
2-17
2-17
2-17
ML6425A3006
ML6425A3014
ML6425B3005
ML6425B3021
ML6435B1008
2-10
2-10
2-10
2-10
2-8
MT010
2-4
M6063L4003
M6410C2023
M6410C2031
M6410C4029
M6410C4037
2-17
2-6
2-6
2-6
2-6
ML6435B1016
ML6661E3010
ML6661E3028
ML6674E3013
ML6674E3021
2-8
2-20
2-20
2-20
2-20
N
N05010
N05010-SW2
N05230-2POS
2-19
2-19
2-19
M6410L2023
M6410L2031
M6410L4029
M6410L4037
M7061E1012
2-6
2-6
2-6
2-6
2-18
ML7161E3010
ML7161E3028
ML7174E3013
ML7174E3021
ML7295E1007
2-20
2-20
2-20
2-20
2-23
N0524
N0524-SW2
N10010
N10010-SW2
N10230-2POS
2-19
2-19
2-19
2-19
2-19
M7061E1020
M7410A1001
M7410C1007
M7410C1015
M7410E1002
2-18
2-4
2-6
2-6
2-7
ML7295E1015
ML7420A3006
ML7420A3014
ML7420A3071
ML7420G1004
2-23
2-11
2-11
2-11
2-15, 7-3
N1024
N1024-SW2
N20010
N20010-SER
N20010-SER-SW2
2-19
2-19
2-21
2-21
2-21
M7410E1028
M7410E2026
M7410E2034
M7410E4022
M7410E4030
2-7
2-7
2-7
2-7
2-7
ML7420G1012
ML7420G1020
ML7421A3004
ML7421B3003
ML7425A3005
2-15, 7-3
2-15, 7-3
2-13
2-13
2-11
N20010-SW2
N20230
N20230-2POS
N20230-P10K
N20230-SW2
2-21
2-21
2-21
2-21
2-21
M7410G1008
M7410G1016
M7410G1024
M7410G1032
M7410G1040
2-14, 7-2
2-14, 7-2
2-14, 7-2
2-14, 7-2
2-14, 7-2
ML7425B3004
ML7430E1005
ML7435E1004
ML8195E1003
ML8195E1011
2-11
2-8
2-8
2-23
2-23
N2024
N2024-2POS
N2024-P10K
N2024-SW2
N34010
2-21
2-21
2-21
2-21
2-21
M7410G1057
M8450A1000
MAU8/Ms
MAU8/Nst
MCD3
2-14, 7-2
2-5
7-6
7-6
10-11
MP904A5047
MP904B5037
MP904B5052
MP904C1026
MP904D1032
9-3
9-3
9-3
9-3
9-3
1
2
3
4
5
6
7
N34230
N3424
NXBC0072V51
NXL0001V35C1N0
NXL0002V35C1N0
2-21
2-21
5-4, 5-5
5-2
5-2
0-7
8
9
10
11
12
13
14
Index of products
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Type
Page
Type
Page
Type
Page
NXL0003V35C1N1
NXL0003V35C2H1
NXL0003V35C5H1
NXL0004V35C1N1
NXL0004V35C2H1
5-2
5-3
5-3
5-2
5-3
NXS0105V35A2H0
NXS0105V35A5H0
NXS0140V35A2H0
NXS0140V35A5H0
NXS0168V35A2H0
5-4
5-5
5-4
5-5
5-4
PSTM400RG34F-R
PSTM600RG12S
PSTM600RG12S-R
PSTM600RG34F
PSTM600RG34F-R
6-31
6-32
6-33
6-30
6-31
NXL0004V35C5H1
NXL0005V35C1N1
NXL0005V35C2H1
NXL0005V35C5H1
NXL0007V35C2H1
5-3
5-2
5-3
5-3
5-3
NXS0168V35A5H0
NXS0205V35A2H0
NXS0205V35A5H0
5-5
5-4
5-5
PSTV01RG12S
PSTV01RG12S-R
PSTV01RG34F
PSTV01RG34F-R
6-32
6-33
6-30
6-31
NXL0007V35C5H1
NXL0009V35C2H1
NXL0009V35C5H1
NXL0012V35C2H1
NXL0012V35C5H1
5-3
5-3
5-3
5-3
5-3
P
P2
PP907A1008
PST001RG34F
8-10
9-13
6-30
Q6371A1006
Q6371C1002
Q6371C1010
NXL0016V35C2H1
NXL0016V35C5H1
NXL0023V35C2H1
NXL0023V35C5H1
NXL0031V35C2H1
5-3
5-3
5-3
5-3
5-3
PST001RG34F-R
PST002AG12S
PST002AG12S-R
PST002AG34F
PST002AG34F-R
6-31
6-33
6-33
6-30
6-31
R
R4
R5
REL2
8-3
8-3
10-13
NXL0031V35C5H1
NXL0038V35C2H1
NXL0038V35C5H1
NXL0046V35C2H1
NXL0046V35C5H1
5-3
5-3
5-3
5-3
5-3
PST002RG12S
PST002RG12S-R
PST002RG34F-R
PST004RG12S
PST004RG12S-R
6-32
6-33
6-31
6-32
6-33
REL3
REL4
RF20
RGT240
RP416A2008
10-13
10-13
6-4
8-8
9-5
NXL0061V35C2H1
NXL0061V35C5H1
NXS0003V35A2H1
NXS0003V35A5H1
NXS0004V35A2H1
5-3
5-3
5-4
5-5
5-4
PST004RG34F
PST004RG34F-R
PST010AG12S
PST010AG12S-R
PST010AG34F
6-30
6-31
6-33
6-33
6-30
RP470A1003
RP471A1002
RP670A1001
RP670A1019
RP7517A1009
9-5
9-5
9-6
9-6
9-8
NXS0004V35A5H1
NXS0005V35A2H1
NXS0005V35A5H1
NXS0007V35A2H1
NXS0007V35A5H1
5-5
5-4
5-5
5-4
5-5
PST010AG34F-R
PST010RG12S
PST010RG12S-R
PST010RG34F
PST010RG34F-R
6-31
6-32
6-33
6-30
6-31
RP7517B1008
RP920A1009
RP920A1017
RP920B1007
RP920C1005
9-8
9-2
9-2
9-2
9-2
NXS0009V35A2H1
NXS0009V35A5H1
NXS0012V35A2H1
NXS0012V35A5H1
NXS0016V35A2H1
5-4
5-5
5-4
5-5
5-4
PST025RG12S
PST025RG12S-R
PST025RG34F
PST025RG34F-R
PST02RG34F
6-32
6-33
6-30
6-31
6-30
RP920D1003
RP970A1008
RP971A1007
RP971A1015
RP972A1006
9-2
9-6
9-7
9-7
9-7
NXS0016V35A5H1
NXS0022V35A2H1
NXS0022V35A5H1
NXS0031V35A2H1
NXS0031V35A5H1
5-5
5-4
5-5
5-4
5-5
PST060RG12S
PST060RG12S-R
PST100RG12S
PST100RG12S-R
PST250RG12S
6-32
6-33
6-32
6-33
6-32
S
S1
S10010
S10010-SW2
8-10
2-22
2-22
NXS0038V35A2H1
NXS0038V35A5H1
NXS0045V35A2H1
NXS0045V35A5H1
NXS0061V35A2H1
5-4
5-5
5-4
5-5
5-4
PST250RG12S-R
PST600RG12S
PST600RG12S-R
PSTM250RG12S
PSTM250RG12S-R
6-33
6-33
6-33
6-32
6-33
S10230-2POS
S10230-2POS-SW2
S1024-2POS
S1024-2POS-SW2
S20010
2-22
2-22
2-22
2-22
2-22
NXS0061V35A5H1
NXS0072V35A2H0
NXS0072V35A5H0
NXS0087V35A2H0
NXS0087V35A5H0
5-5
5-4
5-5
5-4
5-5
PSTM250RG34F
PSTM250RG34F-R
PSTM400RG12S
PSTM400RG12S-R
PSTM400RG34F
6-30
6-31
6-32
6-33
6-30
S20010-SW2
S20230-2POS
S20230-2POS-SW2
S2024-2POS
S2024-2POS-SW2
2-22
2-22
2-22
2-22
2-22
0-8
http://europe.hbc.honeywell.com
Q
10-8
10-8
10-8
Index of products
Type
Page
Type
Page
S6040A1003
S6065A1003
S6065A2001
S7014A1004
S7014B1000
6-42
6-43
6-43
6-19
6-19
SW2
SWF62
SWF62L
2-21
6-42
6-42
S7014C1009
SAF25
SDBAM1
SDBAM16
SDBAM2,5
6-19
6-40
6-29
6-29
6-29
T
T4NST
T5NST
T6120A1005
SDBAM32
SDBAM6
SDBAM625
SK10
SK10-AK
6-29
6-29
6-29
6-35
6-35
SK20
SK20-AK
SK5
SK5-AK
SKN1250-L
Type
T7416A1022
T7425A1005
T7425A1005-L
T7425A1013
T7425A1013-L
Page
6-7
6-6
7-5
6-6
7-5
8-4, 8-8
8-5, 8-6, 8-7
8-9
T7425A1021
T7425B1011
T7425B1029
T7460A1001
T7460B1009
6-6
6-11
6-11
6-20
6-20
T6120A1013
T6120A1021
T6120A1039
T6120B1003
T631C1160
8-9
8-9
8-9
8-9
8-9
T7460C1007
T7460D1005
T7460E1002
T7460F1000
T7460H
6-20
6-20
6-20
6-21
6-3
6-35
6-35
6-35
6-35
7-7
T631C1178
T6950A1000
T6950A1018
T6950A1026
T6951A1009
8-9
8-2
8-2
8-2
8-2
T7460LIMITER
T7460LONJACK
T7470A1009
T7560A1000
T7560A1018
6-21
6-21
6-3
6-21
6-21
SKN250-L
SKV10
SKV10-AK
SKV5
SKV5-AK
7-7
6-35
6-35
6-35
6-35
T6951A1017
T6951A1025
T6960A1008
T6960A1016
T6960A1024
8-2
8-2
8-2
8-2
8-2
T7560A1026
T7560B1008
T7560B1016
T7560B1024
T7560BLINDS
6-21
6-21
6-21
6-21
6-21
SKVN1250-L
SKVN250-L
SLF3
SN025-355-L
SN10-355-L
7-7
7-7
6-41
7-8
7-8
T6961A1007
T6961A1015
T6961A1023
T7036A1022
T7411A1001
8-2
8-2
8-2
6-15
6-12
T7560C1006
T7560H
TP937A1006
TP937B1004
TP938A1005
6-16
6-3
9-10
9-10
9-10
SN1-355-L
SN25-355-L
SN3-355-L
SN6-355-L
SP470A1042
7-8
7-8
7-8
7-8
9-13
T7411A1019
T7411A1043
T7412A1000
T7412A1018
T7412A1026
6-12
6-40
6-4, 6-18
6-9
6-14
TP938A1013
TP938B1003
TP939A1004
TP939B1002
TP940A1001
9-10
9-10
9-10
9-10
9-10
SP470A1059
SP970A1021
SP970A1039
ST12-4-A
ST12-4-A-AK
9-13
9-13
9-13
6-31, 6-33
6-33
T7412A1059
T7412B1008
T7412B1016
T7412B1024
T7412B1040
6-40
6-4, 6-18
6-9
6-14
6-9
TP970A2020
TP970B2010
TP974A2000
TRE100
TRE250
9-11
9-11
9-11
10-10
10-10
ST12-4-A-GK
ST12-4-AK
ST12-4-G
ST12-4-GK
ST12-5-A
6-33
6-31
6-31, 6-33
6-31
6-31, 6-33
T7412B1057
T7412C1006
T7412C1030
T7412D1004
T7412E1001
6-9
6-4, 6-18
6-9
6-5, 6-19
6-5, 6-19
TRE40
TRE60
TRM022
TRM150
TRM40
10-10
10-10
8-10
8-10
8-10
ST12-5-G
ST355
STA12
STB+TR
STB+TW
6-31, 6-33
7-7
6-31, 6-33
8-5
8-7
T7412E1027
T7413A1009
T7413A1041
T7413A1058
T7414A1008
6-5, 6-19
6-10
6-10
6-10
6-10
TRMV150
TRMV40
TST355
TWP1
8-10
8-10
7-7
8-8
STB1
STU25
STU32
STW+TR
STW1
8-4
4-13
4-13
8-6
8-4
T7414C1004
T7414C1012
T7415A1007
T7415A1015
T7416A1014
6-12
6-6
6-11
6-11
6-12
U
U430B
UB430B
6-23, 6-24, 6-27, 6-28, 6-29
6-31, 6-33
0-9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Index of products
1
Type
Page
V
Type
Page
Type
Page
2
V5011R1000
V5011R1018
V5011R1026
3-10
3-10
3-10
V5025A1019
V5025A1027
V5025A1035
V5025A1043
V5025A1050
3
V5011R1034
V5011R1042
V5011R1059
V5011R1067
V5011R1075
3-10
3-10
3-10
3-10
3-10
V5025A1068
V5025A1076
V5025A1084
V5025A1092
V5025A1100
3-16
3-16
3-16
3-16
3-16
V5328A1039
V5328A1047
V5328A1054
V5328A1062
V5328A1070
3-12
3-12
3-12
3-12
3-12
V5011R1083
V5011R1091
V5011S1005
V5011S1013
V5011S1021
3-10
3-10
3-10
3-10
3-10
V5025A1118
V5025A1126
V5025A1134
V5025A1142
V5025A1159
3-16
3-16
3-16
3-16
3-16
V5328A1088
V5328A1096
V5328A1104
V5328A1112
V5328A1138
3-12
3-12
3-12
3-12
3-12
V5011S1039
V5011S1047
V5011S1054
V5011S1062
V5011S1070
3-10
3-10
3-10
3-10
3-10
V5025A1167
V5049A1201
V5049A1219
V5049A1227
V5049A1425
3-16
3-12
3-12
3-12
3-18
V5328A1146
V5328A1153
V5329A1004
V5329A1012
V5329A1020
3-12
3-12
3-38
3-38
3-38
V5011S1088
V5011S1096
V5013E1063
V5013E1071
V5013E1089
3-10
3-10
3-32
3-32
3-32
V5049A1433
V5049A1441
V5049A1458
V5049A1508
V5049A1565
3-18
3-18
3-18
3-18
3-18
V5329A1038
V5329A1046
V5329A1053
V5329A1061
V5329A1079
3-38
3-38
3-38
3-38
3-38
V5013E1097
V5013E1105
V5013E1113
V5013E1121
V5013R1032
3-32
3-32
3-32
3-32
3-34
V5049A1573
V5049A1581
V5049A1599
V5049A1607
V5049A1615
3-18
3-18
3-18
3-18
3-18
V5329A1087
V5329C1000
V5329C1018
V5329C1026
V5329C1034
3-38
3-36
3-36
3-36
3-36
V5013R1040
V5013R1057
V5013R1065
V5013R1073
V5013R1081
3-34
3-34
3-34
3-34
3-34
V5049A1623
V5049A2027
V5049A2035
V5049A2043
V5050A1090
3-18
3-18
3-18
3-18
3-38
V5329C1042
V5329C1059
V5329C1067
V5329C1075
V5329C1083
3-36
3-36
3-36
3-36
3-36
V5013R1099
V5015A1151
V5015A1169
V5015A1177
V5016A1010
3-34
3-36
3-36
3-36
3-14
V5050A1108
V5050A1116
V5050A1124
V5050A1132
V5050A1140
3-38
3-38
3-40
3-40
3-40
V5421B1009
V5421B1017
V5421B1025
V5421B1033
V5421B1041
4-3
4-3
4-3
4-3
4-3
V5016A1028
V5016A1036
V5016A1044
V5016A1051
V5016A1069
3-14
3-14
3-14
3-14
3-14
V5050A1157
V5050A1165
V5050A1173
V5050A1181
V5050A1199
3-40
3-40
3-40
3-40
3-40
V5421B1058
V5421B1066
V5421B1074
V5421B1082
V5421B1090
4-3
4-3
4-3
4-3
4-3
V5016A1077
V5016A1085
V5016A1093
V5016A1101
V5016A1119
3-14
3-14
3-14
3-14
3-14
V5050A1207
V5050A1215
V5050B1064
V5050B1072
V5050B1080
3-40
3-40
3-38
3-38
3-38
V5421C1007
V5421C1015
V5421C1023
V5421C1031
V5421C1049
4-2
4-2
4-2
4-2
4-2
V5016A1127
V5016A1135
V5016A1143
V5016A1150
V5016A1168
3-14
3-14
3-14
3-14
3-14
V5050B1155
V5078B1005
V5078B1013
V5078B1021
V5078B1039
3-40
3-20
3-20
3-20
3-20
V5421C1056
V5421C1064
V5421C1072
V5421C1080
V5421C1098
4-2
4-2
4-2
4-2
4-2
4
5
6
7
8
9
10
11
12
13
14
0-10
http://europe.hbc.honeywell.com
3-16
3-16
3-16
3-16
3-16
V5078B1047
V5078B1054
V5328A1005
V5328A1013
V5328A1021
3-20
3-20
3-12
3-12
3-12
Index of products
Type
Page
Type
Page
Type
Page
V5421C1106
V5421C1114
V5421C1122
V5421C1130
V5421C1148
4-2
4-2
4-2
4-2
4-2
V5434T1069
V5434T1077
V5434T1085
V5441A1023
V5441A1031
4-13
4-13
4-13
4-10
4-10
V5823C2165
V5823C4005
V5823C4013
V5825B1001
V5825B1019
3-24
3-24
3-24
3-8
3-8
V5421C1155
V5421C1163
V5422E1001
V5422E1019
V5422E1027
4-2
4-2
4-5
4-5
4-5
V5441A1049
V5441A1056
V5441A1064
V5441F1048
V5441F1055
4-10
4-10
4-10
4-10
4-10
V5825B1027
V5825B1035
V5825B1043
V5825B1050
V5825B1068
3-8
3-8
3-8
3-8
3-8
V5422E1035
V5422E1043
V5422E1050
V5422E1068
V5422L1006
4-5
4-5
4-5
4-5
4-4
V5441F1063
V5441F1071
V5441F1089
V5441F1097
V5441F1105
4-10
4-10
4-10
4-10
4-10
V5825B1076
V5825B1084
V5832A1004
V5832A1012
V5832A1020
3-8
3-8
3-4
3-4
3-4
V5422L1014
V5422L1022
V5422L1030
V5422L1048
V5422L1055
4-4
4-4
4-4
4-4
4-4
V5441F1113
V5441F1121
V5441F1139
V5442A1022
V5442A1030
4-10
4-10
4-10
4-11
4-11
V5832A1038
V5832A1046
V5832A1053
V5832A1061
V5832A1079
3-4
3-4
3-4
3-4
3-4
V5422L1063
V5431A1025
V5431A1033
V5431A1041
V5431A1058
4-4
4-6
4-6
4-6
4-6
V5442A1048
V5442A1055
V5442G1003
V5442G1011
V5442G1029
4-11
4-11
4-12
4-12
4-12
V5832A4008
V5832A4016
V5832B2075
V5832B2083
V5832B2091
3-4
3-4
3-6
3-6
3-6
V5431A1066
V5431F1032
V5431F1040
V5431F1057
V5431F1065
4-6
4-6
4-6
4-6
4-6
V5442G1037
V5822A1006
V5822A1014
V5822A1022
V5822A1030
4-12
3-2
3-2
3-2
3-2
V5832B2109
V5832B2117
V5833A1003
V5833A1011
V5833A1029
3-6
3-6
3-26
3-26
3-26
V5431F1073
V5431F1081
V5431F1099
V5431F1107
V5431F1115
4-6
4-6
4-6
4-6
4-6
V5822A1048
V5822A1055
V5822A1063
V5822A1071
V5822A4000
3-2
3-2
3-2
3-2
3-2
V5833A1037
V5833A1045
V5833A1052
V5833A1060
V5833A2076
3-26
3-26
3-26
3-26
3-30
V5431F1123
V5433A1015
V5433A1023
V5433A1031
V5433A1049
4-6
4-8
4-8
4-8
4-8
V5822A4018
V5823A2003
V5823A2011
V5823A2029
V5823A2037
3-2
3-22
3-22
3-22
3-22
V5833A2084
V5833A2092
V5833A2100
V5833A2118
V5833A3009
3-30
3-30
3-30
3-30
3-26
V5433A1056
V5433A1064
V5433A1072
V5433G1004
V5433G1012
4-8
4-8
4-8
4-9
4-9
V5823A2045
V5823A2052
V5823A2060
V5823A2151
V5823A2169
3-22
3-22
3-22
3-22
3-22
V5833A3017
V5833A4007
V5833A4015
V5833C1009
V5833C1017
3-26
3-26
3-26
3-28
3-28
V5433G1020
V5433G1038
V5433G1046
V5433G1053
V5433G1061
4-9
4-9
4-9
4-9
4-9
V5823A4009
V5823A4017
V5823C2009
V5823C2017
V5823C2025
3-22
3-22
3-24
3-24
3-24
V5833C1025
V5833C1033
V5833C1041
V5833C1058
V5833C1066
3-28
3-28
3-28
3-28
3-28
V5434T1010
V5434T1028
V5434T1036
V5434T1044
V5434T1051
4-13
4-13
4-13
4-13
4-13
V5823C2033
V5823C2041
V5823C2058
V5823C2066
V5823C2157
3-24
3-24
3-24
3-24
3-24
V5833C1140
V5833C1152
V5833C4003
V5833C4011
VF20A
3-28
3-28
3-28
3-28
6-5
0-11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Index of products
1
2
3
4
5
Type
Page
VF20L
VF20L-L
VF20LN
VF20NT
VF20T
6-5
7-4
6-5
6-5
6-5
VF20T-L
VFHT
VFL
VFLN
VFNT
Type
Page
W
Type
Page
Y
WB20
WLP1
WPF20A
2-21
8-10
6-5
7-4
6-6, 6-10, 6-11
6-10
6-10
6-6, 6-10, 6-11
WPF20L
WPF20T
WTU25
WTU32
WV108
6-5
6-5
4-13
4-13
3-2, 3-4, 3-22, 3-24, 3-26, 3-28
Z
Z100-AG
Z100-AGE
Z100-AO
2-3
2-3
2-3
VKD3
VKD5
VMP10-90
VMS2
VMU1
7-6
7-6
2-18
2-18
2-18
WV108B
3-2, 3-4, 3-22, 3-24, 3-26, 3-28
Z100-BG
Z100-BGE
Z100-BO
2-3
2-3
2-3
VRS1
2-18
X
XIFHP1
XIFLP1
6
7
8
9
10
11
12
13
14
0-12
http://europe.hbc.honeywell.com
7-7
7-7
Y103755B
6-14
General Information
Page
1
2
3
4
5
6
7
8
9
10
11
12
13
14
General Information
General Information
1
Best choice
Application
2
Valve Type
Steam Heat-
Cool-
ing
ing
FCU
AHU
DH
High
DHW
∆p
Small Linear Valves
3
4
PN16
V582x
-
+
+
+
o
-
-
-
PN16
V583x
-
+
+
+
o
-
-
-
PN25
V5825B
+
+
o
-
o
+
+
o
Large Linear Valves
5
6
7
8
PN16
V5011R
-
+
+
-
+
-
-1)
o
PN16
V5011S
+
+
+
-
+
+
-1)
o
PN16
V5013R
-
+
+
-
+
-
-1)
o
PN16
V5013E
-
+
+
-
+
-
-1)
o
PN16
V5328/V5049
o
+
+
-
+
+
-1)
-
PN6/16
V5329/V5015/V5050
-
+
+
-
+
-
-1)
-
PN16
V5016
+
+
+
-
-
+
+
-
PN25
V5025
+
+
+
-
-
+
+
-
PN25/40
V5049
+
+
+
-
-
+
-1)
-
PN25/40
V5050
-
+
+
-
+
-
-1)
-
9
Rotary Valves
10
PN6
V54x A/F
-
+
+
-
-
-
-
-
PN6
V5433/42
-
+
+
-
-
-
-
-
-
+
+
-
-
-
+
o
Butterfly Valves
11
PN16
V5421B
Legend:
12
13
+
“Best choice”
o
“Possible”
-
“Not recommended”
-1)
“High ∆p for small nominal sizes”
Please note:
14
This table is only a recommendation. A valve marked with a "+" is a preferred choice in specific
applications.
Also a valve marked with a "-" may be suitable for an application but overspecified.
1-2
http://europe.hbc.honeywell.com
General Information
1
Phase over list
Old type
New type
Valves
2
V5812A
V5822A
V5813A
V5823A
V5813C
V5823C
VP-Types
No replacement
VMY-Types
V5025A
V5832B1xxx DN25...40
V5832B2xxx DN25...40
V5833A1xxx DN25...40
V5833A2xxx DN25...40
V176A/B
V5016A
V5095A
V5016A
V5025B
V5025A
V5872B
V5825B
V5077A/B
V5832A/B or V5825B
Old type
3
4
5
6
New type
Actuators
M656A1002 (230 Vac, floating, 2aux)
ML6410L4029 (230 Vac, floating, 2aux),
+ Adapterring 0903403
M656B1001 (24 Vac, floating, 2aux)
ML6410L4029 (24 Vac, floating, 2aux),
+ Adapterring 0903403
M6421A1000
(24 Vac, floating, 20 mm stroke)
ML6421A3005
(24 Vac, floating, 20 mm stroke)
M6421B1008
(24 Vac, floating, 38 mm stroke)
ML6421B3004
(24 Vac, floating, 38 mm stroke)
M6421A1026
(230 Vac, floating, 20 mm stroke)
ML6421A3013
(230 Vac, floating, 20 mm stroke)
M6421B1024
(230 Vac, floating, 38 mm stroke)
ML6421B3012
(230 Vac, floating, 38 mm stroke)
M7421A1008
(24 Vac, 2..10V, 20 mm stroke)
ML7421A3004
(24 Vac, 0(2)..10V, 20 mm,
feedback signal)
M7421A1016
(24 Vac, 2..10V, 20 mm stroke)
M7421B1006
(24 Vac, 2..10V, 38 mm stroke)
M7421A1014
(24 Vac, 2..10V, 38 mm stroke)
7
8
9
10
11
ML7421A3003
(24 Vac, 0(2)..10V, 38 mm,
feedback signal)
12
ML6425B2015
(24 Vac, floating, 6,5 mm stroke)
ML6435B1008
(24 Vac, floating, 6,5 mm stroke)
ML6425B2023
(230 Vac, floating, 6,5 mm stroke)
ML6435B1016
(230 Vac, floating, 6,5 mm stroke)
ML7420A2016
(24 Vac, 0/2..10V, 6,5 mm stroke)
ML7430E1005
(24 Vac, 0/2..10V, 6,5 mm stroke)
ML7420A3048
(24 Vac, 0/2..10V, 20 mm stroke)
ML7420A3014
(24 Vac, 0/2..10V, 20 mm stroke)
M452A/B
M6410L/C + Adaptering 0903403
13
14
1-3
General Information
1
Phase over list
Old type
New type
Damper actuators
2
3
4
5
6
7
8
9
ML6185E1006
S10010
ML6185E1014
S10010-SW2
ML7285E1003
S10010
ML4195E1002
S20230-2POS
ML4195E1010
S20230-2POS-SW2
ML8195E1003
S2024-2POS
ML8195E1011
S2024-2POS-SW2
ML7295E1007
S20010
ML7295E1015
S20010-SW2
ML6161E3011
N0524
ML6661E3010
N05230-2POS*
ML7161E3010
N05010
ML6161E3029
N0524-SW2
ML6661E3028
N05230-2POS* + accessory
ML7161E3028
N05010-SW2
ML6174E3014
N1024
ML6674E3013
N10230-2POS*
ML7174E3013
N10010
ML6174E3022
N1024-SW2
ML6674E3021
N10230-2POS* + accessory
ML7174E3021
N10010-SW2
* not direct replacement
10
11
12
13
14
1-4
http://europe.hbc.honeywell.com
General Information
1
Valve parts materials
Valve
Body
Stem
V5822A/32A
Yellow brass
V5823A,C/V5833A,C
Plug
Seat
Stem Seal
stainless steel Brass/EPDM
Yellow brass
EPDM
Yellow brass
stainless steel Brass/EPDM
Yellow brass
EPDM
V5833A/V5832B, DN25-40
Yellow brass
stainless steel Brass
Yellow brass
EPDM
V5825B
Rg5
stainless steel stainless steel stainless steel EPDM
2
3
4
V5011R
Yellow brass
stainless steel Brass
stainless steel PTFE
V5011S
Yellow brass
stainless steel stainless steel stainless steel PTFE
V5013R
Yellow brass
stainless steel Brass
stainless steel PTFE
V5013E
Yellow brass
stainless steel Brass
stainless steel PTFE
V5328A
GG-25
stainless steel stainless steel stainless steel PTFE
V5049A PN16
GG-25
stainless steel stainless steel stainless steel PTFE
V5016A
GGG 40.3
stainless steel stainless steel stainless steel PTFE
V5025A
GGG 40.3
stainless steel stainless steel stainless steel PTFE
V5049A PN25/40
GS-C25
stainless steel stainless steel stainless steel PTFE
GG-25
stainless steel stainless steel body
integrated
GG-25
stainless steel stainless steel stainless steel PTFE
GG-25
stainless steel stainless steel body
integrated
PTFE
GG-25
stainless steel Rg5
PTFE
GS-C25
stainless steel stainless steel stainless steel PTFE
5
6
7
8
9
V5329A
V5050A PN16 <DN100-150
V5329C
V5015A
V5050A PN25/40
body
integrated
PTFE
10
11
12
13
14
1-5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
1-6
http://europe.hbc.honeywell.com
Actuators
Overview: Small linear actuators
Small linear actuators, stroke 2,5/6,5mm
Overview: Large linear actuators
Large linear actuators, stroke 20/38mm
LON linear actuators
Overview: Rotary valve actuators
Rotary valve actuators
Damper actuators
Page
2-2
2-3
2-9
2-10
2-14
2-16
2-17
2-19
1
2
3
4
5
6
7
8
9
10
11
12
13
14
12
8
10
13
14
2-2
http://europe.hbc.honeywell.com
2)
7
1)
6
–
–
Only for On/Off valves V58xxA4xxx
TÜV approval according to DIN 32730
•
•2)
•
PN16
•2)
PN16
V5833A
DN15-20
V5833A
DN25-40
V5078B
PN16
V5823A
V5825B
PN25
2)
–
–
V5832B
PN16
–
–
–
V5832A
PN16
2)
•2)
•2)
V5822A
PN16
–
•2)
90 N 90 N
•2)
PN16
4
–
•
•
•
–
–
•
•
96 N
–
•2)
•
2)
–
–
–
•2)
•2)
90 N
–
•
•
•
–
–
•
•
180 N
•
–
–
–
•
•
–
–
300 N
–
•
–
–
•
•
•
–
–
–
•
•
•
180 N
•1)
–
–
400 N
Order No. Z100 M100 M8450A M7410A M6410C/L M6410C/L ML6435B M7410E
M7410C M7410C spring return
M4450A
•
–
–
–
•
•
–
–
300 N
•
–
–
–
•
•
–
–
400 N
M7410E ML7430E
Modulating
3
Nominal
5
SMALL LINEAR VALVES & ACTUATORS
Floating
–
•
–
–
•1)
•
–
–
400 N
ML7435E
spring return
2
PN16
9
On/Off
1
3-way
2-way
11
Control Mode
Overview: Small linear actuators
Overview: Small linear actuators
Small linear actuators, stroke 2,5/6,5mm
Small linear actuators, stroke 2,5/6,5mm
1
Actuator thermoelectric for terminal unit/radiator valves, 2,5 mm 90 N, M100/Z100
Electrical actuator on/off control, for valve series: V135, V58..A4, V58..C4. Z100-motors also suitable for V136-series valves.
Protection class
IP43 (IP40 for horizontal mounting)
End switch function/capacity
SPST; capacity 5 A
Stem force
90 N
Control input signal
2-pt
Stroke
2,5 mm
Cable length
1m
2
3
4
2,5 mm; 90 N; compact size
Power supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
Action at power loss
Built in end switches
stem retracts
stem retracts
stem extends
stem extends
stem extends
stem extends
–
–
–
–
1
1
Runtime
min
3,0
3,0
3,0
3,0
3,0
3,0
Initial current
A
0,3
0,6
0,3
0,6
0,3
0,6
Type
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
5
Runtime
min
5,5
5,5
5,5
5,5
Initial current
A
0,05
0,2
0,05
0,2
Type
7
Runtime
min
4,0
5,0
4,0
5,0
4,0
5,0
Initial current
A
0,7
0,7
0,7
0,7
0,7
0,7
Type
6
2,5 mm; 90 N; compact size, low initial current
Power supply
Vac; VA
230; 2
24; 2
230; 2
24; 2
Action at power loss
Built in end switches
stem retracts
stem retracts
stem extends
stem extends
–
–
–
–
Action at power loss
Built in end switches
stem retracts
stem retracts
stem extends
stem extends
stem extends
stem extends
–
–
–
–
1
1
M100-BOX
M100-AOX
M100-BGX
M100-AGX
8
2,5 mm; 90 N
Power supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
9
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
10
11
12
13
14
2-3
Small linear actuators, stroke 2,5/6,5mm
1
Actuator thermoelectric 0..10V for terminal unit/radiator valves, 2,5 mm 90 N, MT010
Electrical actuator for valve series: V58..A4, V58..C4, V100, V90.
For thermostatic radiator valves with connection size: M30 x 1,5.
2
3
4
Protection class
IP40
Stem force
90 N
Power supply
24 Vac; 1,5 VA
Control input signal
0..10V=
Stroke
2,5 mm
Runtime
90 s
Cable length
1m
Initial current
0,25 A
2,5 mm; 90 N
Type
MT010
5
Actuator 3-pt for terminal unit/radiator valves, 2,5 mm 90 N, M7410A
6
Electrical actuator floating control, for valve series: V135, V136, V58..A4, V58..C4.
7
8
9
Protection class
IP43
Position indication
with red indicator
Stem force
90 N
Power supply
24 Vac; 0,7 VA
Control input signal
3-pt
Stroke
2,5 mm
Runtime
57 s
Cable length
0,9 m
Additional description
Manual operation with valve cap.
2,5 mm; 90 N
Type
M7410A1001
10
Accessories
Adapter for Danfoss RA2000
11
12
13
14
2-4
http://europe.hbc.honeywell.com
IRA-AD
Small linear actuators, stroke 2,5/6,5mm
1
Fast motoric actuator for terminal unit/radiator valves, 2,5/6,5 mm 90 N, M5410
Electrical actuator on/off control, for valve series V58.. DN15/20 and V100/V2000 TRV-series.
Protection class
IP54
Stem force
90 N
Control input signal
2-pt
2
Cable length
1,5 m
Additional description
Manual operation with valve cap.
3
2,5 mm; 90 N
Power supply
Vac; VA
24; 8
230; 1,5
230; 1,5
Stroke
mm
2,5
2,5
2,5
Action at power loss
stem retracts
stem retracts
stem extends
Runtime
s
1,4/6
1,4/6
1,4/6
Type
4
M5410C4005
M5410L4005
M5410L4500
5
6,5 mm; 90 N
Power supply
Vac; VA
24; 8
230; 1,5
230; 1,5
Stroke
mm
6,5
6,5
6,5
Action at power loss
stem retracts
stem retracts
stem extends
Runtime
s
3,6/16
3,6/16
3,6/16
Type
6
M5410C1001
M5410L1001
M5410L1506
7
Actuator thermoelectric for zone control, 6,5 mm 90 N, M4450/M8450
Electrical actuator on/off control, for valve series: V5822, V5823, V5832, V5833.
Protection class
IP43 (IP40 for horizontal mounting)
Stem force
90 N
Control input signal
2-pt
Stroke
6,5 mm
Action at power loss
stem retracts
Cable length
2,5 m
Initial current
0,7 A
8
9
10
6,5 mm; 90 N
Power supply
Vac; VA
230; 3
24; 3
Runtime
min
4,0
5,0
Type
11
M4450A1009
M8450A1000
12
13
14
2-5
Small linear actuators, stroke 2,5/6,5mm
1
Actuator 3-pt for zone control, 6,5 mm 180/300 N, M6410/M7410
Electrical actuator floating control, for valve series: V5822, V5823, V5832, V5833. And also for
V5077B/V5078B valve series (with adapter).
2
3
Protection class
IP43/IP42
Position indication
with red indicator
End switch function/capacity
SPDT; capacity 1 A inductive, 5 A resistive
Control input signal
3-pt
Stroke
6,5 mm
Runtime
150 s
4
Cable length
1,5 m
Additional description
For M7410-models, the valve cap can be used for manual adjustment. For models with 2 end switches, the 2nd switch is adjustable.
5
6,5 mm; 180 N
Stem force
N
180
180
180
180
180
6
7
Power supply
Vac; VA
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
Manual operation
Built in end switches
–
•
•
•
•
–
–
2
–
2
Power supply
Vac; VA
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
Manual operation
Built in end switches
–
•
•
•
•
–
–
2
–
2
Type
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
6,5 mm; 300 N
Stem force
N
300
300
300
300
300
8
9
Type
M7410C1015
M6410C2031
M6410C4037
M6410L2031
M6410L4037
Accessories
10
Adapter for valve series V5077B/V5078B
11
12
13
14
2-6
http://europe.hbc.honeywell.com
0903403
Small linear actuators, stroke 2,5/6,5mm
1
Actuator 0/2..10V for zone control, 6,5 mm 180/300 N, M7410E
Electrical actuator modulating control, for valve series: V5822, V5823, V5832, V5833.
Protection class
IP42
2
Position indication
with red indicator
End switch function/capacity
SPDT, capacity 1A inductive, 5A resistive
Power supply
24 Vac; 1,4 VA
3
Control input signal
0/2..10V=
Stroke
6,5 mm
Runtime
150 s
Cable length
1,5 m
Additional description
The control action is reversable. For M7410E1..-models, the valve
cap can be used for manual adjustment. For models with 2 end
switches, the 2nd switch is adjustable.
4
5
6,5 mm; 180 N
Stem force
N
180
180
180
Manual operation
Built in end switches
–
•
•
–
–
2
Stem force
N
300
300
300
Manual operation
Built in end switches
–
•
•
–
–
2
Type
M7410E1002
M7410E2026
M7410E4022
6
6,5 mm; 300 N
7
Type
M7410E1028
M7410E2034
M7410E4030
8
9
10
11
12
13
14
2-7
Small linear actuators, stroke 2,5/6,5mm
1
Actuator 0/2..10V for district heating, DHWS, 6,5 mm 400 N, ML7430/ML7435
Electrical actuator modulating control, for valve series: V5825B. Also suitable for V5832B/V5833Aseries (DN25..40).
2
3
Protection class
IP54
Stem force
400 N
Control input signal
0/2..10V=
Stroke
6,5 mm
Additional description
For ML7435E1004: approved according DIN32730 in combination
with V5825B.
6,5 mm; 400 N
4
Power supply
Vac; VA
24; 5
24; 10
5
Action at power loss
Manual operation
–
stem retracts
•
–
Runtime
s
15
60
Spring return
–
•
Type
ML7430E1005
ML7435E1004
Actuator 3-pt for district heating, DHWS, spring return, 6,5 mm 400 N, ML6435
6
Electrical actuator floating control, for valve series: V5825B. Also suitable for V5832B/V5833A-series (DN25..40)
7
8
Protection class
IP54
Stem force
400 N
Control input signal
3-pt
Stroke
6,5 mm
Action at power loss
stem retracts
Runtime
60 s
Spring return
yes
Additional description
Approved according DIN32730 in combination with V5825B.
6,5 mm; 400 N
9
Power supply
Vac; VA
24; 10
230; 10
10
11
12
13
14
2-8
http://europe.hbc.honeywell.com
Type
ML6435B1008
ML6435B1016
(1
PN25/40
PN16
PN16
PN6
PN6
•
–
DN15-80
V5329A
V5050A,B
–
•
DN15-65
DN15-80
–
•
–
•
DN15-65
(1
DN15-80(1
DN15-80
–
DN15-80(1
–
•(1
•
•
600 N
ML6425A/B
DN15-80
V5050A,B
V5015A
V5329C
V5049A
V5025A
V5016A
V5049A
•
•
V5013R,E
V5328A
•
600 N
ML6420A
V5011R,S
Order No.
10
11
TÜV approval according to DIN 32730
3-way
PN25/40
PN25
PN16
PN16
PN16
2-way
Flanged
Valves
PN16
PN16
Threaded 2-way
valves 3-way
Nominal
Control Mode
–
•
•
•
600 N
ML7420A
DN100-150 DN15-80
DN100-150 DN15-80
•
–
–
–
1800 N
M6421B
•
DN100
DN15-80
–
•
–
–
•
–
•
DN15-80
–
•
–
•
DN15-65 DN80-100 DN15-65
–
–
–
•
•
•
1800 N
M6421A
LARGE LINEAR VALVES & ACTUATORS
Floating
Spring Return Actuators
DN15-80
–
•
–
•
DN15-65(1
DN15-80(1
DN15-80(1
–
•(1
•
•
600 N
ML7425A/B
Modulating
Spring Return Actuators
DN100-150
–
DN15-80
–
•
–
•
DN100
•
–
•
–
DN15-65 DN80-100
DN100-150
•
–
–
–
1800 N
M7421B
–
–
•
•
•
1800 N
M7421A
Overview: Large linear actuators
Overview: Large linear actuators
1
2
3
4
5
6
7
8
9
12
13
14
2-9
Large linear actuators, stroke 20/38mm
Large linear actuators, stroke 20/38mm
1
Actuator 3-pt, 20 mm 600 N, ML6420/ML6425
Electrical actuator floating control, for valve series: V5011, V5013, V5016A, V5025, V5049, V5050,
V5328, V5329.
2
3
4
Protection class
IP54
Position indication
scale plate
Stem force
600 N
Control input signal
3-pt
Stroke
20 mm
Additional description
For ML6425-models: approved according DIN32730 in combination with V5016A/V5025A/V5328A/V5049A.
20 mm; 600 N
Power supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
5
6
7
Action at power loss
Manual operation
–
–
–
–
–
stem extends
stem retracts
stem extends
stem retracts
•
–
•
•
•
•
•
•
•
Runtime
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
Spring return
–
–
–
–
–
•
•
•
•
Type
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
Accessories
8
Dual end switches SPDT, adjustable (250 V~, 10 A)
43191680-005
Feedback potentiometer 10 kohm, operating range
43191679-011
Feedback potentiometer 220/135 ohm operating range
43191679-012
High temperature kits for:
9
V5011R/S, V5013R/E; V5328A/V5329A DN15..32
43196000-001
V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/
V5329A DN40..80
43196000-002
10
11
12
13
14
2-10
http://europe.hbc.honeywell.com
Large linear actuators, stroke 20/38mm
1
Actuator 0/2..10V, 20 mm 600 N, ML7420/ML7425
Electrical actuator modulating control, for valve series: V5011, V5013, V5016A, V5025, V5049,
V5050, V5328, V5329.
2
Protection class
IP54
Position indication
scale plate
Stem position at control
signal loss
selectable: closed, half open, open
Stem force
600 N
Control input signal
0/2..10V=
Stroke
20 mm
Feedback signal of position
2..10V=
Additional description
The control action is reversable. For ML7425-models: approved
according DIN32730 in combination with V5016A/V5025A/
V5328A/V5049A.
3
4
5
20 mm; 600 N
Power supply
Vac; VA
24; 5
24; 5
24; 7
24; 12
24; 12
Action at power loss
Manual operation
–
–
–
stem extends
stem retracts
•
–
•
•
•
Runtime
min
1,0
1,0
0,5
1,8
1,8
Spring return
–
–
–
•
•
Type
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
6
7
Accessories
Dual end switches SPDT, adjustable (250 V~, 10 A)
43191680-005
Feedback potentiometer 10 kohm, operating range
43191679-011
Feedback potentiometer 220/135 ohm operating range
43191679-012
High temperature kits for:
V5011R/S, V5013R/E; V5328A/V5329A DN15..32
43196000-001
V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/
V5329A DN40..80
43196000-002
8
9
10
11
12
13
14
2-11
Large linear actuators, stroke 20/38mm
1
Actuator 3-pt, 20/38 mm 1800 N, ML6421
Electrical actuator floating control, for valve series: V5011, V5013, V5015, V5016, V5025, V5049,
V5050, V5328, V5329.
2
3
Protection class
IP54
Position indication
scale plate on the yoke
Stem force
1800 N
Control input signal
3-pt
Manual operation
yes
20 mm; 1800 N
4
5
Power supply
Vac; VA
24; 11
230; 11
Stroke
mm
20
20
Runtime
min
1,9
1,9
Type
Power supply
Vac; VA
24; 11
230; 11
Stroke
mm
38
38
Runtime
min
3,5
3,5
Type
ML6421A3005
ML6421A3013
38 mm; 1800 N
6
ML6421B3004
ML6421B3012
Accessories
7
8
Dual end switches SPDT, adjustable (250 V~, 10 A)
43191680-002
Single feedback potentiometer 220/135 ohm operating range, for 20 mm models
43191679-001
Single feedback potentiometer 10 kohm operating range, for 20 mm models
43191679-007
Single feedback potentiometer 220/135 ohm operating range, for 38 mm models
43191679-002
Single feedback potentiometer 10 kohm operating range, for 38 mm models
43191679-008
High temperature kits for:
9
V5011R/S, V5013R/E; V5328A/V5329A DN15..32
43196000-001
V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/
V5329A DN40..80
43196000-002
V5015A/V5016A/V5025A/V5049A/V5050A/B 38 mm
43196000-038
10
11
12
13
14
2-12
http://europe.hbc.honeywell.com
Large linear actuators, stroke 20/38mm
1
Actuator 0/2..10V, 20/38 mm 1800 N, ML7421
Electrical actuator modulating control, for valve series: V5011, V5013, V5015, V5016, V5025,
V5049, V5050, V5328, V5329.
Protection class
IP54
Position indication
scale plate
Stem position at control
signal loss
selectable: closed, half open, open
Stem force
1800 N
Power supply
24 Vac; 12 VA
Control input signal
0/2..10V=; 0/4..20mA=
Manual operation
yes
Feedback signal of position
2..10V=
2
3
4
20 mm; 1800 N
Stroke
mm
20
Runtime
min
1,9
5
Type
ML7421A3004
6
38 mm; 1800 N
Stroke
mm
38
Runtime
min
3,5
Type
ML7421B3003
7
Accessories
Dual end switches SPDT, adjustable (250 V~, 10 A)
43191680-002
8
High temperature kits for:
V5011R/S, V5013R/E; V5328A/V5329A DN15..32
43196000-001
V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/
V5329A DN40..80
43196000-002
V5015A/V5016A/V5025A/V5049A/V5050A/B 38 mm
43196000-038
9
10
11
12
13
14
2-13
LON linear actuators
LON linear actuators
1
Actuator + PI-controller LON for radiator valves/zone control, 2,5/6,5 mm 90/180/300
N, M7410G
Electrical actuator with LON input signal for the following valve types:
• 2,5 mm stroke: V100 (thermostatic valves), V58..A4, V58..C4 series
• 6,5 mm stroke: V5822, V5823, V5832, V5833, V5825 series
2
3
4
Protection class
IP42
Position indication
with red indicator
LonMark(R) profile
input SNVT percent 0-100%; for actuators with PI-control object:
open loop actuator object type 3, controller object type 20000
Transceiver type
FTT 10A
Power supply
24 Vac; 1,4 VA
Control input signal
LON
Cable length
1,5 m
Additional description
Contact input available for override function fully open or closed.
Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
5
2,5 mm; 90 N
Stem force
N
90
90
6
7
Stroke
mm
2,5
2,5
Runtime
s
53
53
PI control object
Stroke
mm
6,5
6,5
Runtime
s
150
150
PI control object
Stroke
mm
6,5
6,5
Runtime
s
150
150
PI control object
–
•
Type
M7410G1008
M7410G1032
6,5 mm; 180 N
Stem force
N
180
180
8
–
•
Type
M7410G1016
M7410G1040
6,5 mm; 300 N
Stem force
N
300
300
9
10
11
12
13
14
2-14
http://europe.hbc.honeywell.com
–
•
Type
M7410G1024
M7410G1057
LON linear actuators
1
Actuator LON, 20 mm 600 N, ML7420G
Electrical actuator with LON capabilities, for valve series: V5011, V5013, V5016A, V5025, V5049,
V5050, V5328, V5329.
Protection class
IP54
Position indication
scale plate
Stem position at control
signal loss
selectable: closed, half open, open
Stem force
600 N
Power supply
24 Vac; 7 VA
2
3
Control input signal
LON
Stroke
20 mm
Manual operation
yes
Runtime
1,0 min
Additional description
The control action is reversable. Actuator parameter set can be
defined by using the available Plug In.
4
5
20 mm; 600 N
Model
–
2 digital Inputs
2 digital Outputs
Type
ML7420G1004
ML7420G1012
ML7420G1020
7
Accessories
Dual end switches SPDT, adjustable (250 V~, 10 A)
6
43191680-005
High temperature kits for:
V5011R/S, V5013R/E; V5328A/V5329A DN15..32
43196000-001
V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/
V5329A DN40..80
43196000-002
8
9
10
11
12
13
14
2-15
Overview: Rotary valve actuators
Overview: Rotary valve actuators
1
2
Rotary Valves
Class
Connection Type
2-way
wafer
Static
DN (mm)
Pressure
Kvs
Valve series
PN10
25..200
52..3093
V5421B
•
•
<DN80
–
25..600
60..24868
V5421C manual operation
–
–
–
–
PN16
250..600 4800..25000
V5422L motorized
–
•
–
–
V5422E motorized
–
–
–
•
3
3-way
4
5
4-way
6
internal
threads
PN6
15..40
4..25
V5431A
•
•
•
–
20..50
2,5..40
V5433A compact
•
•
–
–
V5433G corrosion protected
•
•
–
–
external
threads
PN10
25..32
2,5..25
V5434T bypass
•
•
•
–
flanges
DIN2531
PN6
20..150
6,3..630
V5431F
•
•
<DN100
–
internal
threads
PN6
15..40
4..25
V5441A
•
•
•
–
20..32
4..16
V5442A compact
•
•
–
–
V5442G corrosion protected
•
•
–
–
flanges
DIN2531
PN6
25..200
10..630
V5441F
•
•
<DN100
–
7
8
9
10
11
12
13
14
2-16
Actuators
Floating
Modulating
24 V
230 V
24 V
230 V
http://europe.hbc.honeywell.com
Rotary valve actuators
Rotary valve actuators
1
Compact Line Rotary Valve Actuator
Electrical actuator for valve series V5433A/G, V5442F/G.
Protection class
IP44
End switch function/capacity
SPST; capacity 1A inductive, 3 A resistive
Torque
7 Nm
Control input signal
3-pt
Angle of rotation
90 o
Manual operation
yes
Runtime
100 s
Cable length
1,5 m
Additional description
Manual operation by declutch of gear.
Power supply
Vac; VA
24; 3
24; 3
230; 3
230; 3
Linkage of M6063L as replacement for M676A,C
2
3
4
Built in end switches
–
2
–
2
Type
5
M6063A1003
M6063A4007
M6063L1009
M6063L4003
6
075041061
7
8
9
10
11
12
13
14
2-17
Rotary valve actuators
1
Standard Line Rotary Valve Actuator
Electrical actuator for valve series V5421, V5431, V5441.
2
3
Protection class
IP54
Position indication
reversable scale plate
Angle of rotation
90 o
Manual operation
yes
Additional description
Manual operation by declutch of gear.
Floating control
4
5
6
Torque
Power supply
Control input signal
Feedback signal of
position
Nm
10
20
30
40
10
20
30
40
Vac; VA
24; 3,5
24; 3,5
24; 3,5
24; 3,5
230; 3,5
230; 3,5
230; 3,5
230; 3,5
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
optional
optional
optional
optional
optional
optional
optional
optional
Torque
Power supply
Control input signal
Feedback signal of
position
Nm
10
20
Vac; VA
24; 2,4
24; 2,4
0/2..10V=
0/2..10V=
–
–
Runtime
min
1,5
1,6
2,3
3,5
1,5
1,6
2,3
3,5
Type
M6061A1013
M6061A1021
M6061A1039
M6061A1047
M6061L1019
M6061L1027
M6061L1035
M6061L1043
Modulating control
7
8
Runtime
min
1,5
3,0
Type
M7061E1012
M7061E1020
Accessories for floating control motors
9
Feedback potentiometer 10 kohm
VMP10-90
Auxiliary switch package
VMS2
Accessories for modulating control motors
10
Feedbacksignal of position 0..10 V
VMU1
Feedback switch
VRS1
11
12
13
14
2-18
http://europe.hbc.honeywell.com
Damper actuators
Damper actuators
1
Damper actuator 5/10 Nm, SmartAct
Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class
IP54
End switch function/capacity
SPDT switch 230 V, 5(3) A for models with end switch
Shaft mounting
for round shafts 8..16 mm; square shafts 6..13 mm
Built in rotation limiter
yes
Manual operation
yes
Additional description
2
3
• removable wiring box for direct wiring to and from controller
• rotation direction selectable by switch
• adjustable mechanical end limits included
• 24 Vac models also suitable for 24 Vdc
4
For damper area of 1 square meter
Power supply
Vac; VA
24; 6
24; 6
230; 6
24; 6
24; 6
Control input signal
Built in end switches
2/3-pt
2/3-pt
2-pt
0/2..10V=;2/3-pt
0/2..10V=;2/3-pt
–
2
–
–
2
Torque
Nm
5
5
5
5
5
Type
Torque
Nm
10
10
10
10
10
Type
5
N0524
N0524-SW2
N05230-2POS
N05010
N05010-SW2
For damper area of 2 square meters
Power supply
Vac; VA
24; 6
24; 6
230; 6
24; 6
24; 6
Control input signal
Built in end switches
2/3-pt
2/3-pt
2-pt
0/2..10V=;2/3-pt
0/2..10V=;2/3-pt
–
2
–
–
2
6
7
N1024
N1024-SW2
N10230-2POS
N10010
N10010-SW2
8
9
Products available in the course of 2005.
10
11
12
13
14
2-19
Damper actuators
1
Damper actuator 5/10 Nm
Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class
2
3
IP54
Position indication
on the housing
Shaft mounting
for round shafts 8..16mm; square shafts 6..12mm
Manual operation
yes
Runtime
150 s;50Hz
Cable length
1m
Additional description
Angle of rotation limiters are part of the delivery.
For damper area of 0,8 square meters
4
Power supply
Vac; VA
24; 4
230; 4
24; 8
24; 4
230; 4
24; 8
5
6
Control input signal
Built in end switches
3-pt
3-pt
0/2..10V=
3-pt
3-pt
0/2..10V=
–
–
–
2
2
2
Torque
Nm
5
5
5
5
5
5
Type
Torque
Nm
10
10
10
10
10
10
Type
ML6161E3011
ML6661E3010
ML7161E3010
ML6161E3029
ML6661E3028
ML7161E3028
For damper area of 1,6 square meters
Power supply
Vac; VA
24; 4
230; 4
24; 8
24; 4
230; 4
24; 8
7
8
9
Control input signal
Built in end switches
3-pt
3-pt
0/2..10V=
3-pt
3-pt
0/2..10V=
–
–
–
2
2
2
ML6174E3014
ML6674E3013
ML7174E3013
ML6174E3022
ML6674E3021
ML7174E3021
Accessories for ML7174E3013, ML7174E3021
Linkage for connection to the valve series V5433, V5442
10
Products will be replaced by SmartAct versions.
11
12
13
14
2-20
http://europe.hbc.honeywell.com
A7116.0050
Damper actuators
1
Damper actuator 20/34 Nm, SmartAct
Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
2
Protection class
IP54
Position indication
rotational angle scales 0..90o, 90..0o
End switch function/capacity
SPDT switch 230V, 5 (3) A for models with end switch
Shaft mounting
for round shafts 10..27 mm; square shafts 10..18 mm
Manual operation
yes
Cable length
1m
Additional description
3
• Rotation direction selectable by switch.
• When power is removed, the actuator remains in position.
• Removable wiring box.
• Actuator supplied with complete package mounting parts.
• For modulating control models: Control input signal can be
voltage or current.
• For modulating control models: Autoadapt dipswitch. With this
function the full span of the control input signal will be used for
the applicable angle or rotation.
• For modulating control SER-models: Adjustable control input
signal. Offset adjustment: 0..10 V=; span adjustment: 2..32 V=.
The angle of rotation is linear to the range set.
4
5
6
For damper area of 4 square meters
Power supply
Control input Built in rotation
signal
limiter
Vac; VA
24; 6
24; 6
24; 6
24; 6
230; 6
230; 6
230; 6
230; 6
24; 6
24; 6
24; 6
24; 6
2/3-pt
2-pt
2/3-pt
2/3-pt
2/3-pt
2-pt
2/3-pt
2/3-pt
0/2..10V=
0/2..10V=
adjustable
adjustable
•
•
•
•
•
•
•
•
•
•
•
•
Built in end
switches
Feedback signal of position
–
–
2
–
–
–
2
–
–
2
–
2
–
–
–
10kohm
–
–
–
10kohm
0/2..10V=
0/2..10V=
0..10V=
0..10V=
Built in end
switches
Feedback signal of position
Runtime
Torque
s
110
110
110
110
110
110
110
110
95
95
95
95
Nm
20
20
20
20
20
20
20
20
20
20
20
20
Runtime
Torque
s
110
110
95
Nm
34
34
34
7
Type
N2024
N2024-2POS
N2024-SW2
N2024-P10K
N20230
N20230-2POS
N20230-SW2
N20230-P10K
N20010
N20010-SW2
N20010-SER
N20010-SER-SW2
Control input Built in rotation
signal
limiter
Vac; VA
24; 7
230; 7
24; 8
2/3-pt
2/3-pt
0/2..10V=
–
–
–
9
10
11
For damper area of 6 square meters
Power supply
8
–
–
–
–
–
0/2..10V=
Type
12
N3424
N34230
N34010
13
Optional accessories
End switch kit, with 2 SPDT freely adjustable end-switches
SW2
Wiring box kit with M20 outlets
WB20
Spare parts kit
A7209.2071
SM mounting kit
A7209.2072
Anti rotation bracket kit
A7209.2073
14
2-21
Damper actuators
1
Damper actuator 10/20 Nm, SmartAct springreturn
Direct-coupled actuator with self-centering shaft adapter.
For air dampers, air handlers, ventilation flaps, louvers and VAV-units.
2
3
4
Protection class
IP54
Position indication
rotational angle scales 0..90o, 90..0o
End switch function/capacity
models with 2 SPDT switches 250 V, 3 (1,5) A; fixed setting at 7o
and 85o
Shaft mounting
for round shafts 10..27 mm; square shafts 13..19 mm
Manual operation
yes
Runtime
90 s;50Hz
Spring return timing
20 s
• Rotation direction selectable by flipping the actuator 180o
around its vertical axis.
• Actuator supplied with complete package mounting parts.
• Autoadapt dipswitch. With this function the full span of the
control input signal will be used for the applicable angle or rotation.
• Actuators come with detachable wiring box.
• Actuator can be locked and manually wound.
Additional description
5
6
For damper area of 2 square meters
7
8
9
Power supply
Control input signal
Built in end switches
Feedback signal of
position
Torque
Vac; VA
24; 6
24; 6
230; 6
230; 6
2-pt
2-pt
2-pt
2-pt
–
2
–
2
–
–
–
–
Nm
10
10
10
10
24; 6
24; 6
0/2..10V=;3-pt
0/2..10V=;3-pt
–
2
0..10V=
0..10V=
10
10
Torque
Type
S1024-2POS
S1024-2POS-SW2
S10230-2POS
S10230-2POSSW2
S10010
S10010-SW2
For damper area of 4 square meters
10
11
Power supply
Control input signal
Built in end switches
Feedback signal of
position
Vac; VA
24; 6
24; 6
230; 6
230; 6
2-pt
2-pt
2-pt
2-pt
–
2
–
2
–
–
–
–
Nm
20
20
20
20
24; 6
24; 6
0/2..10V=;3-pt
0/2..10V=;3-pt
–
2
0..10V=
0..10V=
20
20
12
13
14
2-22
http://europe.hbc.honeywell.com
Type
S2024-2POS
S2024-2POS-SW2
S20230-2POS
S20230-2POSSW2
S20010
S20010-SW2
Damper actuators
1
Damper actuator 16 Nm spring return
Direct coupled actuators for air dampers, ventilation flaps, louvers and VAV-units.
Protection class
IP54
Position indication
on actuator hub
End switch function/capacity
SPDT switch 230V, 3A resistive, 1,5 A inductive for models with
end switch
Shaft mounting
for round shafts 8..26 mm, square shafts 6..18 mm
2
Built in rotation limiter
yes
Manual operation
yes
Runtime
90 s;50Hz
Cable length
0,9 m
Torque
16 Nm
Spring return
yes
Additional description
Damper area 3 m2 with 16 Nm torque.
3
4
5
Power supply
Vac; VA
230; 9
230; 9
24; 8
24; 8
24; 9
24; 9
Control input signal
Built in end switches
Feedback signal of position
2-pt
2-pt
2-pt
2-pt
0..10V=
0..10V=
–
2
–
2
–
2
–
–
–
–
0..10V=
0..10V=
Type
ML4195E1002
ML4195E1010
ML8195E1003
ML8195E1011
ML7295E1007
ML7295E1015
Products will be replaced by SmartAct versions.
6
7
8
9
10
11
12
13
14
2-23
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2-24
http://europe.hbc.honeywell.com
Valves linear
2-way linear valves, stroke 2,5/6,5mm
2-way linear valves, stroke 20/38mm
3-way linear valves, stroke 2,5/6,5mm
3-way linear valves, stroke 20/38mm
Page
3-2
3-10
3-20
3-32
1
2
3
4
5
6
7
8
9
10
11
12
13
14
2-way linear valves, stroke 2,5/6,5mm
2-way linear valves, stroke 2,5/6,5mm
1
Two-way control valve PN16, conical sealing DN15/20, V5822A
For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water
(max. 50% glycol), water quality VDI2035.
2
3
4
Valve series
V5822A
Valve type
2-way
Medium type
water
Materials
body DN15 brass, DN20 red brass, stem stainless steel, plug
brass
Action to open
stem up
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
conical sealing
Additional description
Valves are supplied with adjustment cap (not for on/off types).
6,5 mm
5
DN size Connection diameter
mm
15
15
15
15
15
15
20
20
6
7
8
inch
G1/2
G1/2
G1/2
G1/2
G1/2
G1/2
1 1/8" x 14
1 1/8" x 14
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
0,16
600
1600
0,25
600
1600
0,4
600
1600
0,63
600
1600
1
180
1200
1,6
180
1200
2,5
50
400
4
50
400
Stroke
Flow char.
Type
mm
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5822A1006
V5822A1014
V5822A1022
V5822A1030
V5822A1048
V5822A1055
V5822A1063
V5822A1071
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
1,6
180
–
2,5
50
–
Stroke
Flow char.
Type
mm
2,5
2,5
on/off
on/off
2,5 mm
DN size Connection diameter
9
mm
15
20
10
inch
G1/2
1 1/8" x 14
V5822A4000
V5822A4018
Accessories
11
12
Compression fitting for DN15 valve, pipe size 15 mm
ACN-15C
Compression fitting for DN20 valve, pipe size 22 mm
ACN-20C
Soldering fitting for DN15 valve, pipe size 12 mm
ACN-15S
Soldering fitting for DN20 valve, pipe size 15 mm
ACN-20S
External threaded fitting for DN15 valve, pipe size 3/8"
ACN-15T
External threaded fitting for DN20 valve, pipe size 1/2"
ACN-20T
Service tool to clean/replace inserts
WV108
Brush for WV108
WV108B
13
14
3-2
http://europe.hbc.honeywell.com
2-way linear valves, stroke 2,5/6,5mm
Control input
signal
2,5 mm; 90 N
6,5 mm; 90 N
6,5 mm; 180 N
Action at
power loss
Manual
operation
Built in end
switches
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
0..10V=
3-pt
LON
LON
Power
supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
230; 2
24; 2
230; 2
24; 2
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
24; 8
230; 1,5
230; 1,5
24; 1,5
24; 0,7
24; 1,4
24; 1,4
Runtime Cable length
Spring
return
valve open
valve open
valve closed
valve closed
valve closed
valve closed
valve open
valve open
valve closed
valve closed
valve open
valve open
valve closed
valve closed
valve closed
valve closed
valve open
valve open
valve closed
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
5,5 min
5,5 min
5,5 min
5,5 min
4,0 min
5,0 min
4,0 min
5,0 min
4,0 min
5,0 min
1,4/6 s
1,4/6 s
1,4/6 s
90 s
53 s
53 s
53 s
m
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,0
0,9
1,5
1,5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
M100-BOX
M100-AOX
M100-BGX
M100-AGX
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
M5410C4005
M5410L4005
M5410L4500
MT010
M7410A1001
M7410G1008
M7410G1032
2-pt
2-pt
2-pt
2-pt
2-pt
24; 8
230; 1,5
230; 1,5
230; 3
24; 3
valve open
valve open
valve closed
valve open
valve open
–
–
–
–
–
–
–
–
–
–
3,6/16 s
3,6/16 s
3,6/16 s
4,0 min
5,0 min
1,5
1,5
1,5
2,5
2,5
–
–
–
–
–
M5410C1001
M5410L1001
M5410L1506
M4450A1009
M8450A1000
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
1
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-3
2-way linear valves, stroke 2,5/6,5mm
1
Two-way control valve PN16, flat sealing DN15/20, V5832A
For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water
(max. 50% glycol), water quality VDI2035.
2
3
4
Valve series
V5832A
Valve type
2-way
Medium type
water
Materials
body DN15 brass, DN20 red brass, stem stainless steel, plug
brass
Action to open
stem up
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
flat sealing
Additional description
Valves are supplied with adjustment cap (not for on/off types).
6,5 mm
5
DN size Connection diameter
mm
15
15
15
15
15
15
20
20
6
7
8
inch
G1/2
G1/2
G1/2
G1/2
G1/2
G1/2
G3/4
G3/4
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
0,16
600
1600
0,25
600
1600
0,4
600
1600
0,63
600
1600
1
180
1200
1,6
180
1200
2,5
50
400
4
50
400
Stroke
Flow char.
Type
mm
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5832A1004
V5832A1012
V5832A1020
V5832A1038
V5832A1046
V5832A1053
V5832A1061
V5832A1079
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
1,6
180
–
2,5
50
–
Stroke
Flow char.
Type
mm
2,5
2,5
on/off
on/off
2,5 mm
DN size Connection diameter
9
mm
15
20
10
inch
G1/2
G3/4
V5832A4008
V5832A4016
Accessories
11
12
Soldering fitting for DN15 valve, pipe size 12 mm
AC-15FS
Soldering fitting for DN20 valve, pipe size 15 mm
AC-20FS
External threaded fitting for DN15 valve, pipe size 3/8"
AC-15FT
External threaded fitting for DN20 valve, pipe size 1/2"
AC-20FT
Service tool to clean/replace inserts
WV108
Brush for WV108
WV108B
13
14
3-4
http://europe.hbc.honeywell.com
2-way linear valves, stroke 2,5/6,5mm
Control input
signal
2,5 mm; 90 N
6,5 mm; 90 N
6,5 mm; 180 N
Action at
power loss
Manual
operation
Built in end
switches
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
0..10V=
3-pt
LON
LON
Power
supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
230; 2
24; 2
230; 2
24; 2
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
24; 8
230; 1,5
230; 1,5
24; 1,5
24; 0,7
24; 1,4
24; 1,4
Runtime Cable length
Spring
return
valve open
valve open
valve closed
valve closed
valve closed
valve closed
valve open
valve open
valve closed
valve closed
valve open
valve open
valve closed
valve closed
valve closed
valve closed
valve open
valve open
valve closed
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
5,5 min
5,5 min
5,5 min
5,5 min
4,0 min
5,0 min
4,0 min
5,0 min
4,0 min
5,0 min
1,4/6 s
1,4/6 s
1,4/6 s
90 s
53 s
53 s
53 s
m
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,0
0,9
1,5
1,5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
M100-BOX
M100-AOX
M100-BGX
M100-AGX
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
M5410C4005
M5410L4005
M5410L4500
MT010
M7410A1001
M7410G1008
M7410G1032
2-pt
2-pt
2-pt
2-pt
2-pt
24; 8
230; 1,5
230; 1,5
230; 3
24; 3
valve open
valve open
valve closed
valve open
valve open
–
–
–
–
–
–
–
–
–
–
3,6/16 s
3,6/16 s
3,6/16 s
4,0 min
5,0 min
1,5
1,5
1,5
2,5
2,5
–
–
–
–
–
M5410C1001
M5410L1001
M5410L1506
M4450A1009
M8450A1000
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
1
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-5
2-way linear valves, stroke 2,5/6,5mm
1
Two-way control valve PN16, flat sealing DN25-40, V5832B
Pressure balanced control valve.
For fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water
quality VDI2035.
2
3
4
5
Valve series
V5832B2
Valve type
2-way press. bal.
Medium type
water
Materials
body red brass, stem stainless steel, plug brass
Action to open
stem down
Stroke
6,5 mm
Media temperature
2 ... 130 oC
Static pressure
PN16
Port connection type
flat sealing
Flow char.
linear
Additional description
Valves are supplied with adjustment cap.
6,5 mm
6
7
8
DN size
Connection diameter
Kvs value
mm
25
25
25
32
40
inch
G1 1/2
G1 1/2
G1 1/2
G2
G2 1/4
4
6,3
10
16
25
Close off pressure
with 300N motor
kPa
1600
1600
1600
1200
1000
Close off pressure
with 400N motor
kPa
1600
1600
1600
1200
1000
Type
V5832B2075
V5832B2083
V5832B2091
V5832B2109
V5832B2117
Accessories
9
External threaded fitting for DN25 valve, pipe size R1"
AC-25T
External threaded fitting for DN32 valve, pipe size R11/4"
AC-32T
External threaded fitting for DN40 valve, pipe size R11/2"
AC-40T
Internal threaded fitting for DN25 valve, pipe size Rp1"
AC-25TF
Internal threaded fitting for DN32 valve, pipe size Rp11/4"
AC-32TF
Internal threaded fitting for DN40 valve, pipe size Rp11/2"
AC-40TF
10
11
12
13
14
3-6
http://europe.hbc.honeywell.com
2-way linear valves, stroke 2,5/6,5mm
Control input
signal
6,5 mm; 300 N
6,5 mm; 400 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
Power
supply
Vac; VA
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
m
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1015
M6410C2031
M6410C4037
M6410L2031
M6410L4037
M7410E1028
M7410E2034
M7410E4030
M7410G1024
M7410G1057
3-pt
3-pt
0/2..10V=
0/2..10V=
24; 10
230; 10
24; 5
24; 10
valve closed
valve closed
–
valve closed
–
–
•
–
–
–
–
–
60 s
60 s
15 s
60 s
–
–
–
–
•
•
–
•
ML6435B1008
ML6435B1016
ML7430E1005
ML7435E1004
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-7
2-way linear valves, stroke 2,5/6,5mm
1
Compact 2-way control valve PN25, pressure balanced, DN15/32,V5825B
Compact district heating valve, with wide application range.
For domestic hot water and district heating; hot water or cold water (max. 50% glycol), water quality VDI2035.
2
3
4
5
6
Valve series
V5825B
Valve type
2-way press. bal.
Medium type
water/steam
Materials
body red bronze (DIN1705), trim stainless steel
Action to open
stem down
Close off pressure with
300N motor
1600 kPa
Close off pressure with
400N motor
2500 kPa
Stroke
6,5 mm
Media temperature
2 ... 130 oC
Static pressure
PN25
Port connection type
flat sealing
Flow char.
equal perc.
Additional description
Approved according DIN32730 in combination with ML7435E/
ML6435B.
6,5 mm
DN size
mm
15
15
15
15
15
20
20
25
32
7
8
9
Connection diameter
inch
G3/4
G3/4
G3/4
G3/4
G3/4
G1
G1
G1 1/4
G1 1/2
Kvs value
0,25
0,4
0,63
1
1,6
2,5
4
6,3
10
Type
V5825B1001
V5825B1019
V5825B1027
V5825B1035
V5825B1043
V5825B1050
V5825B1068
V5825B1076
V5825B1084
Accessories
10
11
12
External threaded fitting for DN15 valve, pipe size R1/2"
ACS-15T
External threaded fitting for DN20 valve, pipe size R3/4"
ACS-20T
External threaded fitting for DN25 valve, pipe size R1"
ACS-25T
External threaded fitting for DN32 valve, pipe size R1 1/4"
ACS-32T
Welding fitting for DN15 valve, pipe size 1/2"
ACS-15W
Welding fitting for DN20 valve, pipe size 3/4"
ACS-20W
Welding fitting for DN25 valve, pipe size 1"
ACS-25W
Welding fitting for DN32 valve, pipe size 1 1/4"
ACS-32W
Adapter kits for in case V5872B models must be replaced with V5825B models
13
14
3-8
For all DN15 V5872B to DN15 V5825B
AK15-15
For V5872B1052 to V5825B1050
AK20-15
For V5872B1060 to V5825B1068
AK20-25
For V5872B1078 to V5825B1076
AK25-25
http://europe.hbc.honeywell.com
2-way linear valves, stroke 2,5/6,5mm
Control input
signal
6,5 mm; 300 N
6,5 mm; 400 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
Power
supply
Vac; VA
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
m
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1015
M6410C2031
M6410C4037
M6410L2031
M6410L4037
M7410E1028
M7410E2034
M7410E4030
M7410G1024
M7410G1057
3-pt
3-pt
0/2..10V=
0/2..10V=
24; 10
230; 10
24; 5
24; 10
valve closed
valve closed
–
valve closed
–
–
•
–
–
–
–
–
60 s
60 s
15 s
60 s
–
–
–
–
•
•
–
•
ML6435B1008
ML6435B1016
ML7430E1005
ML7435E1004
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-9
2-way linear valves, stroke 20/38mm
2-way linear valves, stroke 20/38mm
1
Two-way control valve PN16, threaded connections DN15-50, V5011R,S
For heating, ventilating and air conditioning; hot/cold water quality VDI2035.
Valve series
2
3
4
V5011R/S
Valve type
2-way
Materials
body brass, stem stainless steel; plug brass or stainless steel
Action to open
stem up
Stroke
20 mm
Media temperature
2 ... 170 oC
Static pressure
PN16
Port connection type
internal threads ISO228
Flow char.
equal perc.
20 mm, plug brass
5
6
7
8
Medium type
DN size
Kvs value
water
water
water
water
water
water
water
water
water
water
mm
15
15
15
15
15
20
25
32
40
50
0,63
1
1,6
2,5
4
6,3
10
16
25
40
Medium type
DN size
Kvs value
water/steam
water/steam
water/steam
water/steam
water/steam
water/steam
water/steam
water/steam
water/steam
water/steam
mm
15
15
15
15
15
20
25
32
40
50
0,63
1
1,6
2,5
4
6,3
10
16
25
40
Close off pressure
with 600N motor
kPa
1600
1600
1600
1600
1600
1600
1000
700
460
260
Close off pressure
with 1800N motor
kPa
–
–
–
–
–
–
1600
1600
1500
850
Type
Close off pressure
with 600N motor
kPa
1600
1600
1600
1600
1600
1600
1000
700
460
260
Close off pressure
with 1800N motor
kPa
–
–
–
–
–
–
1600
1600
1500
850
Type
V5011R1000
V5011R1018
V5011R1026
V5011R1034
V5011R1042
V5011R1059
V5011R1067
V5011R1075
V5011R1083
V5011R1091
20 mm, plug stainless steel
9
10
11
12
13
14
3-10
http://europe.hbc.honeywell.com
V5011S1005
V5011S1013
V5011S1021
V5011S1039
V5011S1047
V5011S1054
V5011S1062
V5011S1070
V5011S1088
V5011S1096
2-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
20 mm; 1800 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
valve closed
valve open
valve closed
valve open
–
–
–
valve closed
valve open
–
–
–
24; 11
230; 11
24; 12
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-11
2-way linear valves, stroke 20/38mm
1
Two-way control valve PN16, flanged connections DN15-150, V5328A/V5049A
For heating and air conditioning; hot/cold water quality VDI2035.
Valve series
2
3
4
V5328A/V5049
Valve type
2-way
Medium type
water/steam
Materials
body cast iron GG25, trim stainless steel
Action to open
stem up
Static pressure
PN16
Port connection type
flanges ISO7005
Flow char.
equal perc.
Additional description
V5328 models DN15..DN50 approved according DIN32730, with
motors ML6425A3006, ML6425A3014, ML7425A3005.
20 mm
5
DN size
mm
15
15
15
15
15
15
15
20
20
25
32
40
50
65
80
6
7
8
9
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
0,25
1600
–
0,4
1600
–
0,63
1600
–
1
1600
–
1,6
1600
–
2,5
1000
1600
4
1000
1600
4
1000
1600
6,3
1000
1600
10
1000
1600
16
600
1600
25
350
1300
40
200
750
63
120
470
100
50
230
Stroke
Media temperature
mm
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
C
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
160
–
230
250
–
90
360
–
90
Stroke
Media temperature
Type
o
V5328A1138
V5328A1146
V5328A1153
V5328A1005
V5328A1013
V5328A1021
V5328A1039
V5328A1047
V5328A1054
V5328A1062
V5328A1070
V5328A1088
V5328A1096
V5328A1104
V5328A1112
38 mm
10
DN size
mm
100
125
150
11
12
13
14
3-12
http://europe.hbc.honeywell.com
mm
38
38
38
Type
o
C
2 ... 220
2 ... 220
2 ... 220
V5049A1201
V5049A1219
V5049A1227
2-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
valve closed
valve open
valve closed
valve open
–
–
–
valve closed
valve open
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
Type
20 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
38 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
2
3
4
5
6
7
8
9
10
11
12
13
14
3-13
2-way linear valves, stroke 20/38mm
1
Two-way control valve PN16, high differential pressure DN15-150, V5016A
Pressure balanced control valve.
For district heating; hot or cold water (max. 50% glycol), water quality VDI2035; or steam.
2
3
4
5
Valve series
V5016A
Valve type
2-way press. bal.
Medium type
water/steam
Materials
body nodular iron GGG40.3, trim stainless steel
Action to open
stem up
Media temperature
2 ... 180 oC
Static pressure
PN16
Port connection type
flanges ISO7005
Flow char.
equal perc.
Additional description
Models DN15..80 approved according DIN32730, with motors
ML6425A3006, ML6425A3014, ML7425A3005.
20 mm
6
7
8
9
DN size
Kvs value
mm
15
15
15
15
15
15
20
25
32
40
50
65
80
0,4
0,63
1
1,6
2,5
4
6,3
10
16
25
40
63
100
DN size
Kvs value
mm
100
125
150
160
250
360
Close off pressure
with 600N motor
kPa
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
Close off pressure
with 1800N motor
kPa
–
–
–
–
–
–
–
–
–
–
–
–
–
Stroke
Close off pressure
with 600N motor
kPa
–
–
–
Close off pressure
with 1800N motor
kPa
1600
1600
1600
Stroke
mm
20
20
20
20
20
20
20
20
20
20
20
20
20
Type
V5016A1010
V5016A1028
V5016A1036
V5016A1044
V5016A1051
V5016A1069
V5016A1077
V5016A1085
V5016A1093
V5016A1101
V5016A1119
V5016A1127
V5016A1135
38 mm
10
11
12
13
14
3-14
http://europe.hbc.honeywell.com
mm
38
38
38
Type
V5016A1143
V5016A1150
V5016A1168
2-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
38 mm; 1800 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
valve closed
valve open
valve closed
valve open
–
–
–
valve closed
valve open
–
–
–
24; 11
230; 11
24; 12
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-15
2-way linear valves, stroke 20/38mm
1
Two-way control valve PN25, high differential pressure DN15-150, V5025A
Pressure balanced control valve.
For district heating; hot or cold water (max. 50% glycol), water quality VDI2035; or steam.
2
3
4
5
Valve series
V5025A
Valve type
2-way press. bal.
Medium type
water/steam
Materials
body nodular iron GGG40.3, trim stainless steel
Action to open
stem up
Media temperature
2 ... 200 oC
Static pressure
PN25
Port connection type
flanges ISO7005
Flow char.
equal perc.
Additional description
Models DN15..80 approved according DIN32730, with motors
ML6425A3006, ML6425A3014, ML7425A3005.
20 mm
6
7
8
9
DN size
Kvs value
mm
15
15
15
15
15
15
20
25
32
40
50
65
80
0,4
0,63
1
1,6
2,5
4
6,3
10
16
25
40
63
100
DN size
Kvs value
mm
100
125
150
160
250
360
Close off pressure
with 600N motor
kPa
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
2500
Close off pressure
with 1800N motor
kPa
–
–
–
–
–
–
–
–
–
–
–
–
–
Stroke
Close off pressure
with 600N motor
kPa
–
–
–
Close off pressure
with 1800N motor
kPa
2500
2500
2500
Stroke
mm
20
20
20
20
20
20
20
20
20
20
20
20
20
Type
V5025A1019
V5025A1027
V5025A1035
V5025A1043
V5025A1050
V5025A1068
V5025A1076
V5025A1084
V5025A1092
V5025A1100
V5025A1118
V5025A1126
V5025A1134
38 mm
10
11
12
13
14
3-16
http://europe.hbc.honeywell.com
mm
38
38
38
Type
V5025A1142
V5025A1159
V5025A1167
2-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
38 mm; 1800 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
valve closed
valve open
valve closed
valve open
–
–
–
valve closed
valve open
–
–
–
24; 11
230; 11
24; 12
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-17
2-way linear valves, stroke 20/38mm
1
Two-way control valve PN40, flanged connections DN15-100, V5049A
For heating and air conditioning; hot/cold water quality VDI2035; steam.
Valve series
2
3
4
5
V5049
Valve type
2-way
Medium type
water/steam
Materials
body cast steel GS-C25, trim stainless steel
Action to open
stem up
Media temperature
2 ... 220 oC
Static pressure
PN40
Port connection type
flanges ISO7005
Flow char.
equal perc.
Additional description
Models DN15..DN65 approved according DIN32730, with motors
ML6425A3006, ML6425A3014, ML7425A3005.
20 mm
DN size
6
7
8
9
Kvs value
mm
15
15
15
15
15
15
15
20
25
32
40
50
65
0,25
0,4
0,63
1
1,6
2,5
4
6,3
10
16
25
40
63
DN size
Kvs value
Close off pressure
with 600N motor
kPa
1600
1600
1600
1600
1600
1000
1000
1000
1000
600
350
200
120
Close off pressure
with 1800N motor
kPa
–
–
–
–
–
2500
2500
2500
2500
2000
1300
750
500
Stroke
Close off pressure
with 600N motor
kPa
–
–
Close off pressure
with 1800N motor
kPa
230
230
Stroke
mm
20
20
20
20
20
20
20
20
20
20
20
20
20
Type
V5049A2027
V5049A2035
V5049A2043
V5049A1425
V5049A1433
V5049A1441
V5049A1458
V5049A1508
V5049A1565
V5049A1573
V5049A1581
V5049A1599
V5049A1607
38 mm
10
mm
80
100
11
100
160
12
13
14
3-18
http://europe.hbc.honeywell.com
mm
38
38
Type
V5049A1615
V5049A1623
2-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
valve closed
valve open
valve closed
valve open
–
–
–
valve closed
valve open
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
Type
20 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
38 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
2
3
4
5
6
7
8
9
10
11
12
13
14
3-19
3-way linear valves, stroke 2,5/6,5mm
3-way linear valves, stroke 2,5/6,5mm
1
Three-way control valve PN16, threaded connections DN15-50, V5078B
For under floor heating, heating and air conditioning; cold/hot water.
Valve series
2
3
4
5
V5078B
Valve type
3-way mixing
Medium type
water
Materials
body red brass RG5, trim stainless steel
Action to open A-AB
stem down
Close off pressure with
180N motor
1000 kPa
Stroke
6,5 mm
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
internal threads ISO228
Flow char.
equal perc.
Additional description
Adaper ring 0903403 must be used for mechanical interface; and
must be ordered seperately.
6,5 mm
6
DN size
mm
15
20
25
32
40
50
7
8
Adapter ring
9
10
11
12
13
14
3-20
http://europe.hbc.honeywell.com
Connection diameter
inch
1/2
3/4
1
1 1/4
1 1/2
2
Kvs value
2,5
3,3
5
5
11
13
Type
V5078B1005
V5078B1013
V5078B1021
V5078B1039
V5078B1047
V5078B1054
0903403
3-way linear valves, stroke 2,5/6,5mm
Control input
signal
6,5 mm; 180 N
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
Power
supply
Vac; VA
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
Action at
power loss
Manual
operation
Built in end
switches
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
Runtime Cable length
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
m
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
Spring
return
–
–
–
–
–
–
–
–
–
–
1
Type
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
2
3
4
5
6
7
8
9
10
11
12
13
14
3-21
3-way linear valves, stroke 2,5/6,5mm
1
Three-way control valve PN16, conical sealing DN15/20, V5823A
For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water
(max. 50% glycol), water quality VDI2035.
2
3
4
5
Valve series
V5823A
Valve type
3-way mixing
Medium type
water
Materials
body red brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
conical sealing
Additional description
Valves are supplied with adjustment cap (not for on/off types). If
the main-port (A-AB) is equal percentage, the B-AB port is linear.
The valve capacity of B-AB is one stage smaller.
6,5 mm
DN size Connection diameter
6
mm
15
15
15
15
15
20
20
20
20
7
8
inch
G1/2
G1/2
G1/2
G1/2
G1/2
1 1/8" x 14
1 1/8" x 14
1 1/8" x 14
1 1/8" x 14
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
0,25
500
800
0,4
500
800
0,63
500
800
1
150
250
1,6
150
250
2,5
–
240
2,5
50
100
4
–
240
4
50
100
Stroke
Flow char.
Type
mm
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5823A2003
V5823A2011
V5823A2029
V5823A2037
V5823A2045
V5823A2151
V5823A2052
V5823A2169
V5823A2060
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
1,6
150
–
2,5
50
–
Stroke
Flow char.
Type
mm
2,5
2,5
on/off
on/off
2,5 mm
9
DN size Connection diameter
mm
15
20
10
inch
G1/2
1 1/8" x 14
V5823A4009
V5823A4017
Accessories
11
12
13
Compression fitting for DN15 valve, pipe size 15 mm
ACN-15C
Compression fitting for DN20 valve, pipe size 22 mm
ACN-20C
Soldering fitting for DN15 valve, pipe size 12 mm
ACN-15S
Soldering fitting for DN20 valve, pipe size 15 mm
ACN-20S
External threaded fitting for DN15 valve, pipe size 3/8"
ACN-15T
External threaded fitting for DN20 valve, pipe size 1/2"
ACN-20T
Service tool to clean/replace inserts
WV108
Brush for WV108
WV108B
14
3-22
http://europe.hbc.honeywell.com
3-way linear valves, stroke 2,5/6,5mm
Control input
signal
2,5 mm; 90 N
6,5 mm; 90 N
6,5 mm; 180 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
0..10V=
3-pt
LON
LON
Power
supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
230; 2
24; 2
230; 2
24; 2
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
24; 8
230; 1,5
230; 1,5
24; 1,5
24; 0,7
24; 1,4
24; 1,4
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
5,5 min
5,5 min
5,5 min
5,5 min
4,0 min
5,0 min
4,0 min
5,0 min
4,0 min
5,0 min
1,4/6 s
1,4/6 s
1,4/6 s
90 s
53 s
53 s
53 s
m
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,0
0,9
1,5
1,5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
M100-BOX
M100-AOX
M100-BGX
M100-AGX
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
M5410C4005
M5410L4005
M5410L4500
MT010
M7410A1001
M7410G1008
M7410G1032
2-pt
2-pt
2-pt
2-pt
2-pt
24; 8
230; 1,5
230; 1,5
230; 3
24; 3
A-AB closed
A-AB closed
A-AB open
A-AB closed
A-AB closed
–
–
–
–
–
–
–
–
–
–
3,6/16 s
3,6/16 s
3,6/16 s
4,0 min
5,0 min
1,5
1,5
1,5
2,5
2,5
–
–
–
–
–
M5410C1001
M5410L1001
M5410L1506
M4450A1009
M8450A1000
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-23
3-way linear valves, stroke 2,5/6,5mm
1
Three-way/bypass control valve PN16, conical sealing DN15/20, V5823C
For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water
(max. 50% glycol), water quality VDI2035.
2
3
4
5
Valve series
V5823C
Valve type
3-way mixing, bypass
Medium type
water
Materials
body red brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
conical sealing
Additional description
Valves are supplied with adjustment cap (not for on/off types). If
the main-port (A-AB) is equal percentage, the B-AB port is linear.
The valve capacity of B-AB is one stage smaller.
6,5 mm
DN size Connection diameter
6
mm
15
15
15
15
15
20
20
20
20
7
8
inch
G1/2
G1/2
G1/2
G1/2
G1/2
1 1/8" x 14
1 1/8" x 14
1 1/8" x 14
1 1/8" x 14
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
0,25
500
800
0,4
500
800
0,63
500
800
1
150
250
1,6
150
250
2,5
–
240
2,5
50
100
4
–
240
4
50
100
Stroke
Flow char.
Type
mm
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5823C2009
V5823C2017
V5823C2025
V5823C2033
V5823C2041
V5823C2157
V5823C2058
V5823C2165
V5823C2066
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
1,6
150
–
2,5
50
–
Stroke
Flow char.
Type
mm
2,5
2,5
on/off
on/off
2,5 mm
9
DN size Connection diameter
mm
15
20
10
inch
G1/2
1 1/8" x 14
V5823C4005
V5823C4013
Accessories
11
12
13
Compression fitting for DN15 valve, pipe size 15 mm
ACN-15C
Compression fitting for DN20 valve, pipe size 22 mm
ACN-20C
Soldering fitting for DN15 valve, pipe size 12 mm
ACN-15S
Soldering fitting for DN20 valve, pipe size 15 mm
ACN-20S
External threaded fitting for DN15 valve, pipe size 3/8"
ACN-15T
External threaded fitting for DN20 valve, pipe size 1/2"
ACN-20T
Service tool to clean/replace inserts
WV108
Brush for WV108
WV108B
14
3-24
http://europe.hbc.honeywell.com
3-way linear valves, stroke 2,5/6,5mm
Control input
signal
2,5 mm; 90 N
6,5 mm; 90 N
6,5 mm; 180 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
0..10V=
3-pt
LON
LON
Power
supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
230; 2
24; 2
230; 2
24; 2
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
24; 8
230; 1,5
230; 1,5
24; 1,5
24; 0,7
24; 1,4
24; 1,4
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
5,5 min
5,5 min
5,5 min
5,5 min
4,0 min
5,0 min
4,0 min
5,0 min
4,0 min
5,0 min
1,4/6 s
1,4/6 s
1,4/6 s
90 s
53 s
53 s
53 s
m
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,0
0,9
1,5
1,5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
M100-BOX
M100-AOX
M100-BGX
M100-AGX
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
M5410C4005
M5410L4005
M5410L4500
MT010
M7410A1001
M7410G1008
M7410G1032
2-pt
2-pt
2-pt
2-pt
2-pt
24; 8
230; 1,5
230; 1,5
230; 3
24; 3
A-AB closed
A-AB closed
A-AB open
A-AB closed
A-AB closed
–
–
–
–
–
–
–
–
–
–
3,6/16 s
3,6/16 s
3,6/16 s
4,0 min
5,0 min
1,5
1,5
1,5
2,5
2,5
–
–
–
–
–
M5410C1001
M5410L1001
M5410L1506
M4450A1009
M8450A1000
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-25
3-way linear valves, stroke 2,5/6,5mm
1
Three-way control valve PN16, flat sealing DN15/20, V5833A
For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water
(max. 50% glycol), water quality VDI2035.
2
3
4
5
Valve series
V5833A
Valve type
3-way mixing
Medium type
water
Materials
body red brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
flat sealing
Additional description
Valves are supplied with adjustment cap (not for on/off types). If
the main-port (A-AB) is equal percentage, the B-AB port is linear.
The valve capacity of B-AB is one stage smaller.
6,5 mm
DN size Connection diameter
6
mm
15
15
15
15
15
20
20
20
20
7
8
inch
G1/2
G1/2
G1/2
G1/2
G1/2
G3/4
G3/4
G3/4
G3/4
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
0,25
500
800
0,4
500
800
0,63
500
800
1
150
250
1,6
150
250
2,5
–
240
2,5
50
100
4
–
240
4
50
100
Stroke
Flow char.
Type
mm
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5833A1003
V5833A1011
V5833A1029
V5833A1037
V5833A1045
V5833A3009
V5833A1052
V5833A3017
V5833A1060
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
1,6
150
–
2,5
50
–
Stroke
Flow char.
Type
mm
2,5
2,5
on/off
on/off
2,5 mm
9
DN size Connection diameter
mm
15
20
10
inch
G1/2
G3/4
V5833A4007
V5833A4015
Accessories
11
12
Soldering fitting for DN15 valve, pipe size 12 mm
AC-15FS
Soldering fitting for DN20 valve, pipe size 15 mm
AC-20FS
External threaded fitting for DN15 valve, pipe size 3/8"
AC-15FT
External threaded fitting for DN20 valve, pipe size 1/2"
AC-20FT
Service tool to clean/replace inserts
WV108
Brush for WV108
WV108B
13
14
3-26
http://europe.hbc.honeywell.com
3-way linear valves, stroke 2,5/6,5mm
Control input
signal
2,5 mm; 90 N
6,5 mm; 90 N
6,5 mm; 180 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
0..10V=
3-pt
LON
LON
Power
supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
230; 2
24; 2
230; 2
24; 2
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
24; 8
230; 1,5
230; 1,5
24; 1,5
24; 0,7
24; 1,4
24; 1,4
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
5,5 min
5,5 min
5,5 min
5,5 min
4,0 min
5,0 min
4,0 min
5,0 min
4,0 min
5,0 min
1,4/6 s
1,4/6 s
1,4/6 s
90 s
53 s
53 s
53 s
m
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,0
0,9
1,5
1,5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
M100-BOX
M100-AOX
M100-BGX
M100-AGX
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
M5410C4005
M5410L4005
M5410L4500
MT010
M7410A1001
M7410G1008
M7410G1032
2-pt
2-pt
2-pt
2-pt
2-pt
24; 8
230; 1,5
230; 1,5
230; 3
24; 3
A-AB closed
A-AB closed
A-AB open
A-AB closed
A-AB closed
–
–
–
–
–
–
–
–
–
–
3,6/16 s
3,6/16 s
3,6/16 s
4,0 min
5,0 min
1,5
1,5
1,5
2,5
2,5
–
–
–
–
–
M5410C1001
M5410L1001
M5410L1506
M4450A1009
M8450A1000
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-27
3-way linear valves, stroke 2,5/6,5mm
1
Three-way/bypass control valve PN16, flat sealing DN15/20, V5833C
For individual room control, fan coil units and small re-heaters/re-coolers; hot water or cold water
(max. 50% glycol), water quality VDI2035.
2
3
4
5
Valve series
V5833C
Valve type
3-way mixing, bypass
Medium type
water
Materials
body red brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Media temperature
2 ... 120 oC
Static pressure
PN16
Port connection type
flat sealing
Additional description
Valves are supplied with adjustment cap (not for on/off types). The
valve capacity for linear ports is one stage smaller than for equal
percentage ports.
6,5 mm
DN size Connection diameter
6
mm
15
15
15
15
15
20
20
20
20
7
8
inch
G1/2
G1/2
G1/2
G1/2
G1/2
G3/4
G3/4
G3/4
G3/4
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
0,25
500
800
0,4
500
800
0,63
500
800
1
150
250
1,6
150
250
2,5
–
240
2,5
50
100
4
–
240
4
50
100
Stroke
Flow char.
Type
mm
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
6,5
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5833C1066
V5833C1009
V5833C1017
V5833C1025
V5833C1033
V5833C1140
V5833C1041
V5833C1152
V5833C1058
Kvs value Close off pres- Close off pressure with 90N
sure with
motor
180N motor
kPa
kPa
1,6
150
–
2,5
50
–
Stroke
Flow char.
Type
mm
2,5
2,5
on/off
on/off
2,5 mm
9
DN size Connection diameter
mm
15
20
10
inch
G1/2
G3/4
V5833C4003
V5833C4011
Accessories
11
12
Soldering fitting for DN15 valve, pipe size 12 mm
AC-15FS
Soldering fitting for DN20 valve, pipe size 15 mm
AC-20FS
External threaded fitting for DN15 valve, pipe size 3/8"
AC-15FT
External threaded fitting for DN20 valve, pipe size 1/2"
AC-20FT
Service tool to clean/replace inserts
WV108
Brush for WV108
WV108B
13
14
3-28
http://europe.hbc.honeywell.com
3-way linear valves, stroke 2,5/6,5mm
Control input
signal
2,5 mm; 90 N
6,5 mm; 90 N
6,5 mm; 180 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
2-pt
0..10V=
3-pt
LON
LON
Power
supply
Vac; VA
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
230; 2
24; 2
230; 2
24; 2
230; 3
24; 3
230; 3
24; 3
230; 3
24; 3
24; 8
230; 1,5
230; 1,5
24; 1,5
24; 0,7
24; 1,4
24; 1,4
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
A-AB open
A-AB open
A-AB open
A-AB closed
A-AB closed
A-AB open
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
–
1
1
–
–
–
–
–
–
–
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
3,0 min
5,5 min
5,5 min
5,5 min
5,5 min
4,0 min
5,0 min
4,0 min
5,0 min
4,0 min
5,0 min
1,4/6 s
1,4/6 s
1,4/6 s
90 s
53 s
53 s
53 s
m
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,0
1,5
1,5
1,5
1,0
0,9
1,5
1,5
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
M100-BO
M100-AO
M100-BG
M100-AG
M100-BGE
M100-AGE
M100-BOX
M100-AOX
M100-BGX
M100-AGX
Z100-BO
Z100-AO
Z100-BG
Z100-AG
Z100-BGE
Z100-AGE
M5410C4005
M5410L4005
M5410L4500
MT010
M7410A1001
M7410G1008
M7410G1032
2-pt
2-pt
2-pt
2-pt
2-pt
24; 8
230; 1,5
230; 1,5
230; 3
24; 3
A-AB closed
A-AB closed
A-AB open
A-AB closed
A-AB closed
–
–
–
–
–
–
–
–
–
–
3,6/16 s
3,6/16 s
3,6/16 s
4,0 min
5,0 min
1,5
1,5
1,5
2,5
2,5
–
–
–
–
–
M5410C1001
M5410L1001
M5410L1506
M4450A1009
M8450A1000
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1007
M6410C2023
M6410C4029
M6410L2023
M6410L4029
M7410E1002
M7410E2026
M7410E4022
M7410G1016
M7410G1040
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-29
3-way linear valves, stroke 2,5/6,5mm
1
Three-way control valve PN16, flat sealing DN25-40, V5833A
Pressure balanced control valve.
For fan coil units and small re-heaters/re-coolers; hot water or cold water (max. 50% glycol), water
quality VDI2035.
2
3
4
5
Valve series
V5833A2
Valve type
3-way mixing, press. bal.
Medium type
water
Materials
body red brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Stroke
6,5 mm
Media temperature
2 ... 130 oC
Static pressure
PN16
Port connection type
flat sealing
Flow char.
linear
Additional description
Valves are supplied with adjustment cap.
6,5 mm
6
7
8
DN size
Connection diameter
Kvs value
mm
25
25
25
32
40
inch
G1 1/2
G1 1/2
G1 1/2
G2
G2 1/4
4
6,3
10
16
25
Close off pressure
with 300N motor
kPa
1600
1600
1600
1200
1200
Close off pressure
with 400N motor
kPa
1600
1600
1600
1200
1200
Type
V5833A2076
V5833A2084
V5833A2092
V5833A2100
V5833A2118
Accessories
9
External threaded fitting for DN25 valve, pipe size R1"
AC-25T
External threaded fitting for DN32 valve, pipe size R11/4"
AC-32T
External threaded fitting for DN40 valve, pipe size R11/2"
AC-40T
Internal threaded fitting for DN25 valve, pipe size Rp1"
AC-25TF
Internal threaded fitting for DN32 valve, pipe size Rp11/4"
AC-32TF
Internal threaded fitting for DN40 valve, pipe size Rp11/2"
AC-40TF
10
11
12
13
14
3-30
http://europe.hbc.honeywell.com
3-way linear valves, stroke 2,5/6,5mm
Control input
signal
6,5 mm; 300 N
6,5 mm; 400 N
Runtime Cable length
Spring
return
1
Action at
power loss
Manual
operation
Built in end
switches
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
Power
supply
Vac; VA
24; 0,7
24; 0,7
24; 0,7
230; 7
230; 7
24; 1,4
24; 1,4
24; 1,4
24; 1,4
24; 1,4
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
–
•
•
–
–
–
–
2
–
2
–
–
2
–
–
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
150 s
m
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
1,5
–
–
–
–
–
–
–
–
–
–
M7410C1015
M6410C2031
M6410C4037
M6410L2031
M6410L4037
M7410E1028
M7410E2034
M7410E4030
M7410G1024
M7410G1057
3-pt
3-pt
0/2..10V=
0/2..10V=
24; 10
230; 10
24; 5
24; 10
A-AB closed
A-AB closed
–
A-AB closed
–
–
•
–
–
–
–
–
60 s
60 s
15 s
60 s
–
–
–
–
•
•
–
•
ML6435B1008
ML6435B1016
ML7430E1005
ML7435E1004
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-31
3-way linear valves, stroke 20/38mm
3-way linear valves, stroke 20/38mm
1
Three-way control valve PN16, flat sealing DN15-50, V5013E
For heating, ventilating and air conditioning, domestic hot water, open circuits; hot/cold water
quality VDI2035.
2
3
4
5
Valve series
V5013E
Valve type
3-way mixing
Medium type
water
Materials
body brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Stroke
20 mm
Media temperature
2 ... 170 oC
Static pressure
PN16
Port connection type
flat sealing
Flow char.
equal perc.
20 mm
6
7
8
DN size
Connection diameter
Kvs value
mm
15
15
20
25
32
40
50
inch
G1 1/8
G1 1/8
G1 1/4
G1 1/2
G2
G2 1/4
G2 3/4
2,5
4
6,3
10
16
25
40
Close off pressure
with 600N motor
kPa
1600
1600
1600
1000
700
460
260
Close off pressure
with 1800N motor
kPa
–
–
–
1600
1600
1500
850
Type
V5013E1063
V5013E1071
V5013E1089
V5013E1097
V5013E1105
V5013E1113
V5013E1121
Accessories
9
Internal threaded fitting for DN15 valve, pipe size Rp1/2"
AC-15TF
Internal threaded fitting for DN20 valve, pipe size Rp3/4"
AC-20TF
Internal threaded fitting for DN25 valve, pipe size Rp1"
AC-25TF
Internal threaded fitting for DN32 valve, pipe size Rp1 1/4"
AC-32TF
Internal threaded fitting for DN40 valve, pipe size Rp1 1/2"
AC-40TF
Internal threaded fitting for DN50 valve, pipe size Rp2"
AC-50TF
10
11
12
13
14
3-32
http://europe.hbc.honeywell.com
3-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
20 mm; 1800 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
A-AB open
A-AB closed
A-AB open
A-AB closed
–
–
–
A-AB open
A-AB closed
–
–
–
24; 11
230; 11
24; 12
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-33
3-way linear valves, stroke 20/38mm
1
Three-way control valve PN16, threaded connections DN15-50, V5013R
For heating, ventilating and air conditioning, domestic hot water, open circuits; hot/cold water
quality VDI2035.
2
3
4
5
Valve series
V5013R
Valve type
3-way mixing
Medium type
water
Materials
body brass, stem stainless steel, plug brass
Action to open A-AB
stem down
Stroke
20 mm
Media temperature
2 ... 170 oC
Static pressure
PN16
Port connection type
internal threads ISO228
Flow char.
equal perc.
20 mm
6
7
DN size
Kvs value
mm
15
15
20
25
32
40
50
2,5
4
6,3
10
16
25
40
8
9
10
11
12
13
14
3-34
http://europe.hbc.honeywell.com
Close off pressure with
600N motor
kPa
1600
1600
1600
1000
700
460
260
Close off pressure with
1800N motor
kPa
–
–
–
1600
1600
1500
850
Type
V5013R1032
V5013R1040
V5013R1057
V5013R1065
V5013R1073
V5013R1081
V5013R1099
3-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
20 mm; 1800 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
A-AB open
A-AB closed
A-AB open
A-AB closed
–
–
–
A-AB open
A-AB closed
–
–
–
24; 11
230; 11
24; 12
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
Type
2
3
4
5
6
7
8
9
10
11
12
13
14
3-35
3-way linear valves, stroke 20/38mm
1
Three-way control valve PN6, flanged connections DN15-150, V5329C/V5015A
For heating and air conditioning; hot/cold water quality VDI2035; greenhouses.
Valve series
2
3
4
V5329C/V5015
Valve type
3-way mixing
Medium type
water
Materials
body cast iron GG25, trim stainless steel
Action to open A-AB
stem down
Static pressure
PN6
Port connection type
flanges ISO7005
Flow char.
equal perc.
20 mm
DN size
5
mm
15
15
20
25
32
40
50
65
80
6
7
8
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
2,5
600
–
4
600
–
6,3
600
–
10
600
–
16
600
–
25
480
600
40
260
600
63
160
600
100
100
400
Stroke
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
140
–
150
220
–
120
310
–
80
Stroke
mm
20
20
20
20
20
20
20
20
20
Media temperature
Type
oC
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
V5329C1000
V5329C1018
V5329C1026
V5329C1034
V5329C1042
V5329C1059
V5329C1067
V5329C1075
V5329C1083
38 mm
DN size
9
mm
100
125
150
10
11
12
13
14
3-36
http://europe.hbc.honeywell.com
mm
38
38
38
Media temperature
Type
o
C
2 ... 120
2 ... 120
2 ... 120
V5015A1151
V5015A1169
V5015A1177
3-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
A-AB open
A-AB closed
A-AB open
A-AB closed
–
–
–
A-AB open
A-AB closed
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
Type
20 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
38 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
2
3
4
5
6
7
8
9
10
11
12
13
14
3-37
3-way linear valves, stroke 20/38mm
1
Three-way control valve PN16, flanged connections DN 15-150, V5329A/V5050A,B
For heating and air conditioning; hot/cold water quality VDI2035; greenhouses.
Valve series
2
3
V5329A/V5050
Medium type
water
Materials
body cast iron GG25, trim stainless steel
Action to open A-AB
stem down
Static pressure
PN16
Port connection type
flanges ISO7005
20 mm
4
5
6
7
Valve type
DN size
Kvs value
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
mm
15
15
20
25
32
40
50
65
80
2,5
4
6,3
10
16
25
40
63
100
Valve type
DN size
Kvs value
3-way mixing
3-way mixing
3-way mixing
mm
100
125
150
160
250
360
Valve type
DN size
Kvs value
3-way diverting
3-way diverting
3-way diverting
mm
100
125
150
Close off
pressure
with 600N
motor
kPa
1000
1000
1000
1000
790
480
260
160
100
Close off
pressure
with 1800N
motor
kPa
–
–
–
–
1000
1000
1000
650
400
Stroke
Close off
pressure
with 600N
motor
kPa
–
–
–
Close off
pressure
with 1800N
motor
kPa
230
90
90
Stroke
mm
38
38
38
C
2 ... 220
2 ... 220
2 ... 220
Close off
pressure
with 600N
motor
kPa
–
–
–
Close off
pressure
with 1800N
motor
kPa
230
90
90
Stroke
Media temperature
mm
20
20
20
20
20
20
20
20
20
Media temperature
Flow char.
Type
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
2 ... 170
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
equal perc.
V5329A1004
V5329A1012
V5329A1020
V5329A1038
V5329A1046
V5329A1053
V5329A1061
V5329A1079
V5329A1087
Media temperature
Flow char.
Type
oC
38 mm, mixing
8
9
10
o
linear
linear
linear
V5050A1090
V5050A1108
V5050A1116
38 mm, diverting
11
12
160
250
360
13
14
3-38
http://europe.hbc.honeywell.com
mm
38
38
38
Flow char.
Type
oC
2 ... 220
2 ... 220
2 ... 220
linear
linear
linear
V5050B1064
V5050B1072
V5050B1080
3-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
A-AB open
A-AB closed
A-AB open
A-AB closed
–
–
–
A-AB open
A-AB closed
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
Type
20 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
38 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
2
3
4
5
6
7
8
9
10
11
12
13
14
3-39
3-way linear valves, stroke 20/38mm
1
Three-way control valve PN25/40, flanged connections DN15-100, V5050A,B
For heating systems, hot water quality VDI2035.
Valve series
2
3
4
V5050
Medium type
water
Materials
body cast steel GS-C25, trim stainless steel
Action to open A-AB
stem down
Media temperature
2 ... 220 oC
Static pressure
PN25/40
Port connection type
flanges ISO7005
Flow char.
linear
20 mm
Valve type
DN size
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
3-way mixing
mm
15
15
20
25
32
40
50
65
80
5
6
7
8
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
2,5
1000
2500
4
1000
2500
6,3
1000
2500
10
1000
2500
16
600
2000
25
350
1300
40
200
750
63
120
500
100
50
230
Stroke
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
160
–
230
Stroke
Kvs value Close off pressure Close off pressure
with 600N motor with 1800N motor
kPa
kPa
160
–
230
Stroke
mm
20
20
20
20
20
20
20
20
20
Type
V5050A1124
V5050A1132
V5050A1140
V5050A1157
V5050A1165
V5050A1173
V5050A1181
V5050A1199
V5050A1207
38 mm, mixing
9
Valve type
DN size
3-way mixing
mm
100
mm
38
Type
V5050A1215
38 mm, diverting
10
Valve type
DN size
11
3-way diverting
mm
100
12
13
14
3-40
http://europe.hbc.honeywell.com
mm
38
Type
V5050B1155
3-way linear valves, stroke 20/38mm
Control input
signal
20 mm; 600 N
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
0/2..10V=
LON
LON
LON
Power
supply
Vac; VA
24; 4
24; 4
24; 6
230; 6,5
230; 6,5
24; 11
24; 11
230; 12
230; 12
24; 5
24; 5
24; 7
24; 12
24; 12
24; 7
24; 7
24; 7
Action at
power loss
Manual
operation
–
–
–
–
–
A-AB open
A-AB closed
A-AB open
A-AB closed
–
–
–
A-AB open
A-AB closed
–
–
–
1
Runtime
Spring return
Feedback signal
of position
•
–
•
•
•
•
•
•
•
•
–
•
•
•
•
•
•
min
1,0
1,0
0,5
1,0
0,5
1,8
1,8
1,8
1,8
1,0
1,0
0,5
1,8
1,8
1,0
1,0
1,0
–
–
–
–
–
•
•
•
•
–
–
–
•
•
–
–
–
–
–
–
–
–
–
–
–
–
2..10V=
2..10V=
2..10V=
2..10V=
2..10V=
–
–
–
ML6420A3007
ML6420A3072
ML6420A3023
ML6420A3015
ML6420A3031
ML6425A3006
ML6425B3005
ML6425A3014
ML6425B3021
ML7420A3006
ML7420A3071
ML7420A3014
ML7425A3005
ML7425B3004
ML7420G1004
ML7420G1012
ML7420G1020
Type
20 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
1,9
1,9
1,9
–
–
–
–
–
2..10V=
ML6421A3005
ML6421A3013
ML7421A3004
38 mm; 1800 N
3-pt
3-pt
0/2..10V=;
0/4..20 mA=
24; 11
230; 11
24; 12
–
–
–
•
•
•
3,5
3,5
3,5
–
–
–
–
–
2..10V=
ML6421B3004
ML6421B3012
ML7421B3003
2
3
4
5
6
7
8
9
10
11
12
13
14
3-41
1
2
3
4
5
6
7
8
9
10
11
12
13
14
3-42
http://europe.hbc.honeywell.com
Valves rotary
Butterfly valves
Rotary valves
Page
4-2
4-6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Butterfly valves
Butterfly valves
1
Manually operated Butterfly valve
For pre adjustment of liquid flow in heating and cooling applications, as well as boiler shut off.
2
3
4
Valve series
V5421C
Valve type
butterfly manual
Medium type
water
Materials
housing ductile iron GGG40, shaft stainless steel
Angle of rotation
90 o
Media temperature
-10 ... 130 oC
Static pressure
PN6/PN10
Port connection type
wafer
Additional description
Without flanges.
DN size
mm
25
32
40
50
65
80
100
125
150
200
250
300
350
400
450
500
600
5
6
7
8
9
Kvs value
60
90
120
189
311
433
745
1219
1805
3093
4825
6946
8269
11036
14115
18056
24868
10
11
12
13
14
4-2
http://europe.hbc.honeywell.com
Max. delta P
kPa
1600
1600
1600
1600
1600
1600
1600
1600
1600
1600
1000
1000
1000
1000
1000
1000
1000
Manual operation
hand lever
hand lever
hand lever
hand lever
hand lever
hand lever
hand lever
hand lever
hand lever
hand lever
worm gear
worm gear
worm gear
worm gear
worm gear
worm gear
worm gear
Type
V5421C1007
V5421C1015
V5421C1023
V5421C1031
V5421C1049
V5421C1056
V5421C1064
V5421C1072
V5421C1080
V5421C1098
V5421C1106
V5421C1114
V5421C1122
V5421C1130
V5421C1148
V5421C1155
V5421C1163
Butterfly valves
1
Butterfly valve DN25..200, without actuator
For heating and cooling applications, or boiler management systems.
Valve series
V5421B
2
Valve type
butterfly for motor
Medium type
water
Materials
housing ductile iron GGG40, shaft stainless steel
Angle of rotation
90 o
Media temperature
-10 ... 130 oC
Static pressure
PN16
Port connection type
wafer
Additional description
Without flanges. Actuators (M60.., M70..) to be ordered seperatley.
DN size
mm
25
32
40
50
65
80
100
125
150
200
Kvs value
3
Max. delta P
kPa
1600
1600
1600
1000
1000
1000
1000
800
600
400
M6061A1021
M6061A1039
M6061A1047
M6061L1027
M6061L1035
M6061L1043
M7061E1020
52
52
120
189
311
433
745
1219
1805
3093
Torque for max. delta P
Nm
5
5
7
12
15
25
40
40
40
40
3-pt
24; 3,5
20
3-pt
24; 3,5
30
3-pt
24; 3,5
40
3-pt
230; 3,5
20
3-pt
230; 3,5
30
3-pt
230; 3,5
40
0/2..10V=
24; 2,4
20
•
•
•
•
•
–
–
–
–
–
–
–
–
–
–
•
–
–
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
–
–
•
–
–
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
•
–
–
–
–
–
4
Type
5
V5421B1009
V5421B1017
V5421B1025
V5421B1033
V5421B1041
V5421B1058
V5421B1066
V5421B1074
V5421B1082
V5421B1090
6
7
8
Control input signal
Power supply [Vac; VA]
Torque [Nm]
V5421B1009
V5421B1017
V5421B1025
V5421B1033
V5421B1041
V5421B1058
V5421B1066
V5421B1074
V5421B1082
V5421B1090
9
10
11
12
13
14
4-3
Butterfly valves
1
Motorized Butterfly valve DN250..600
Butterfly valve with factory mounted electrical actuator.
For heating water containing up to 50% glycol.
2
3
4
5
6
Valve series
V5422L/E
Valve type
butterfly motorized
Medium type
water
Materials
body ductile iron GG25 RilsanTM epoxy coated, disc GGG40,
shaft stainless steel
Protection class
IP67
Position indication
mechanical pointer
End switch function/capacity
SPST 230 Vac
Max. delta P
1000 kPa
Angle of rotation
max. 90 o
Media temperature
-10 ... 130 oC
Static pressure
PN10
Port connection type
wafer
Manual operation
with wheel
Built in end switches
2
Additional description
Without flanges.
3-pt control
7
8
9
DN size
Kvs value
Torque
Power supply
Runtime
mm
250
300
350
400
450
500
600
4800
7000
8300
11000
14000
18000
25000
Nm
600
600
800
1200
1500
2500
4000
Vac; VA
230; 276
230; 276
230; 460
230; 276
230; 575
230; 575
230; 575
s
30
30
30
60
60
105
120
10
11
12
13
14
4-4
http://europe.hbc.honeywell.com
Control input signal
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
3-pt
Type
V5422L1006
V5422L1014
V5422L1022
V5422L1030
V5422L1048
V5422L1055
V5422L1063
Butterfly valves
Modulating control and electrical position indication, Microswitch settings for signals values 0/
2..10V, 0/4..20mA
DN size
Kvs value
Torque
Power supply
Runtime
mm
250
4800
Nm
600
Vac; VA
230; 276
s
30
300
7000
600
230; 276
30
350
8300
800
230; 460
30
400
11000
1200
230; 276
60
450
14000
1500
230; 575
60
500
18000
2500
230; 575
105
600
25000
4000
230; 575
120
Control input signal
0/2..10V=; 0/
4..20mA=
0/2..10V=; 0/
4..20mA=
0/2..10V=; 0/
4..20mA=
0/2..10V=; 0/
4..20mA=
0/2..10V=; 0/
4..20mA=
0/2..10V=; 0/
4..20mA=
0/2..10V=; 0/
4..20mA=
1
Type
2
V5422E1001
V5422E1019
3
V5422E1027
V5422E1035
4
V5422E1043
V5422E1050
5
V5422E1068
6
7
8
9
10
11
12
13
14
4-5
Rotary valves
Rotary valves
1
Three-way rotary valve PN6
For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
2
3
4
Valve series
V5431A/F
Valve type
3-way rotary mixing
Medium type
water
Materials
body cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 130 oC
Static pressure
PN6
Reduced delta P
40 kPa
Internal threads
5
DN size
Kvs value
Max. delta P
mm
15
20
25
32
40
4
6,3
10
16
25
kPa
100
100
100
100
100
DN size
Kvs value
Max. delta P
mm
20
25
32
40
50
65
80
100
125
150
6,3
10
16
25
40
63
100
160
250
630
kPa
100
100
100
100
100
100
100
100
70
50
6
7
Torque for max.
delta P
Nm
10
10
10
10
20
Torque for reduced delta P
Nm
10
10
10
10
10
Torque for max.
delta P
Nm
10
10
10
20
20
20
30
40
40
40
Torque for reduced delta P
Nm
10
10
10
10
20
20
20
30
30
40
Port connection
type
Type
internal threads
internal threads
internal threads
internal threads
internal threads
V5431A1025
V5431A1033
V5431A1041
V5431A1058
V5431A1066
Port connection
type
Type
Flanges
8
9
10
11
12
13
14
4-6
http://europe.hbc.honeywell.com
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
flanges DIN2531
V5431F1032
V5431F1040
V5431F1057
V5431F1065
V5431F1073
V5431F1081
V5431F1099
V5431F1107
V5431F1115
V5431F1123
M6061A1021
M6061A1039
M6061A1047
M6061L1019
M6061L1027
M6061L1035
M6061L1043
M7061E1012
3-pt
24; 3,5
10
3-pt
24; 3,5
20
3-pt
24; 3,5
30
3-pt
24; 3,5
40
3-pt
230; 3,5
10
3-pt
230; 3,5
20
3-pt
230; 3,5
30
3-pt
230; 3,5
40
0/2..10V=
24; 2,4
10
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
–
–
•
–
–
–
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
–
–
•
–
–
–
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
M7061E1020
M6061A1013
Rotary valves
1
0/2..10V= Control input signal
24; 2,4 Power supply [Vac; VA]
Torque [Nm]
20
–
–
–
–
•
–
–
–
•
•
•
•
–
–
–
V5431A1025
V5431A1033
V5431A1041
V5431A1058
V5431A1066
V5431F1032
V5431F1040
V5431F1057
V5431F1065
V5431F1073
V5431F1081
V5431F1099
V5431F1107
V5431F1115
V5431F1123
2
3
4
5
6
7
8
9
10
11
12
13
14
4-7
Rotary valves
1
Three-way rotary valve PN6, compact
For heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series
2
3
4
V5433A
Valve type
3-way rotary mixing, compact
Medium type
water
Materials
body cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 110 oC
Static pressure
PN6
Port connection type
internal threads
Max. delta P
100 kPa
Torque for max. delta P
7 Nm
5
DN size
mm
20
20
20
25
32
40
50
V5433A1015
V5433A1023
V5433A1031
V5433A1049
V5433A1056
V5433A1064
V5433A1072
Linkage for connection to the damper actuators ML7174E3013, ML7174E3021 for
modulating control
A7116.0050
M6063A4007
M6063L1009
M6063L4003
11
M6063A1003
10
A7116.0050
7
9
x
x
x
3-pt
24; 3
7
3-pt
24; 3
7
3-pt
230; 3
7
3-pt
230; 3
7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
12
13
14
4-8
Type
2,5
4
6,3
10
16
25
40
6
8
Kvs value
http://europe.hbc.honeywell.com
Control input signal
Power supply [Vac; VA]
Torque [Nm]
V5433A1015
V5433A1023
V5433A1031
V5433A1049
V5433A1056
V5433A1064
V5433A1072
Rotary valves
1
Three-way rotary valve PN6, compact, corrosion protected
Corrosion protected 3-way valve. For hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series
V5433G
Valve type
3-way rotary mixing, compact
Medium type
water (potable)
2
Materials
body chrome plated cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 110 oC
Static pressure
PN6
Port connection type
internal threads
Max. delta P
100 kPa
Torque for max. delta P
7 Nm
3
4
DN size
mm
20
20
20
25
32
40
50
Kvs value
2,5
4
6,3
10
16
25
40
A7116.0050
M6063A1003
M6063A4007
M6063L1009
M6063L4003
Linkage for connection to the damper actuators ML7174E3013, ML7174E3021 for
modulating control
x
x
x
3-pt
24; 3
7
3-pt
24; 3
7
3-pt
230; 3
7
3-pt
230; 3
7
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
5
Type
V5433G1004
V5433G1012
V5433G1020
V5433G1038
V5433G1046
V5433G1053
V5433G1061
6
7
A7116.0050
8
9
Control input signal
Power supply [Vac; VA]
Torque [Nm]
V5433G1004
V5433G1012
V5433G1020
V5433G1038
V5433G1046
V5433G1053
V5433G1061
10
11
12
13
14
4-9
Rotary valves
1
Four-way rotary valve PN6
For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
2
3
4
Valve series
V5441A/F
Valve type
4-way rotary mixing
Medium type
water
Materials
body cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 130 oC
Static pressure
PN6
Internal threads
DN size
5
Kvs value
Max. delta P
4
kPa
100
Torque for
max. delta P
Nm
10
Reduced delta
P
kPa
40
Torque for reduced delta P
Nm
10
mm
15
20
6,3
100
10
40
10
25
10
100
10
40
10
32
16
100
10
40
10
40
25
100
20
40
10
DN size
Kvs value
Max. delta P
mm
25
10
kPa
100
Torque for
max. delta P
Nm
10
Reduced delta
P
kPa
40
Torque for reduced delta P
Nm
10
32
16
100
10
40
10
40
25
100
20
40
10
50
40
100
20
40
20
65
63
100
20
40
20
80
100
100
30
40
20
100
160
80
40
40
30
125
250
50
40
40
30
150
400
40
40
40
40
200
630
30
40
30
40
6
7
Port connection type
internal
threads
internal
threads
internal
threads
internal
threads
internal
threads
Type
V5441A1023
V5441A1031
V5441A1049
V5441A1056
V5441A1064
Flanges
8
9
10
11
12
13
14
4-10
http://europe.hbc.honeywell.com
Port connection type
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
flanges
DIN2531
Type
V5441F1048
V5441F1055
V5441F1063
V5441F1071
V5441F1089
V5441F1097
V5441F1105
V5441F1113
V5441F1121
V5441F1139
M6061A1021
M6061A1039
M6061A1047
M6061L1019
M6061L1027
M6061L1035
M6061L1043
M7061E1012
3-pt
24; 3,5
3-pt
24; 3,5
3-pt
24; 3,5
3-pt
24; 3,5
3-pt
230; 3,5
3-pt
230; 3,5
3-pt
230; 3,5
3-pt
230; 3,5
0/2..10V=
24; 2,4
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
•
–
–
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
•
–
–
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
–
–
–
–
–
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
1
M7061E1020
M6061A1013
Rotary valves
0/2..10V= Control input signal
24; 2,4 Power supply [Vac; VA]
–
–
–
–
•
–
–
•
•
•
•
–
–
–
–
V5441A1023
V5441A1031
V5441A1049
V5441A1056
V5441A1064
V5441F1048
V5441F1055
V5441F1063
V5441F1071
V5441F1089
V5441F1097
V5441F1105
V5441F1113
V5441F1121
V5441F1139
2
3
4
5
6
Four-way rotary valve PN6, compact
For heating systems; hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series
V5442A
Valve type
4-way rotary mixing, compact
Medium type
water
Materials
body cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 110 oC
Static pressure
PN6
Port connection type
internal threads
Max. delta P
100 kPa
Torque for max. delta P
7 Nm
7
8
9
Type
10
4
6,3
10
16
V5442A1022
V5442A1030
V5442A1048
V5442A1055
11
Linkage for connection to the damper actuators ML7174E3013, ML7174E3021 for
modulating control
A7116.0050
M6063A1003
M6063A4007
M6063L1009
M6063L4003
Kvs value
A7116.0050
DN size
mm
20
20
25
32
x
x
3-pt
24; 3
3-pt
24; 3
3-pt
230; 3
3-pt
230; 3
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
12
13
Control input signal
Power supply [Vac; VA]
14
V5442A1022
V5442A1030
V5442A1048
V5442A1055
4-11
Rotary valves
1
Four-way rotary valve PN6, compact, corrosion protected
Corrosion protected 4-way valve. For hot/cold water quality VDI2035; glycol water mixture 50%.
Valve series
2
3
4
V5442G
Valve type
4-way rotary mixing, compact
Medium type
water (potable)
Materials
body chrome plated cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 110 oC
Static pressure
PN6
Port connection type
internal threads
Max. delta P
100 kPa
Torque for max. delta P
7 Nm
5
DN size
mm
20
20
25
32
V5442G1003
V5442G1011
V5442G1029
V5442G1037
Linkage for connection to the damper actuators ML7174E3013, ML7174E3021 for
modulating control
A7116.0050
M6063A1003
M6063A4007
M6063L1009
M6063L4003
9
A7116.0050
8
Type
4
6,3
10
16
6
7
Kvs value
x
x
3-pt
24; 3
3-pt
24; 3
3-pt
230; 3
3-pt
230; 3
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Control input signal
Power supply [Vac; VA]
V5442G1003
V5442G1011
V5442G1029
V5442G1037
10
Three-way rotary valve PN10
For supply water, heating and air conditioning; hot/cold water quality VDI2035; glycol water mixture 50%.
11
Valve series
12
13
V5434T
Valve type
3-way rotary mixing, bypass
Medium type
water
Materials
body cast iron, inner parts chrome plated
Packing
double O-ring sealing
Angle of rotation
90 o
Media temperature
2 ... 130 oC
Static pressure
PN10
Port connection type
external threads
Max. delta P
100 kPa
14
4-12
http://europe.hbc.honeywell.com
Rotary valves
1
Universal Rotary Valve
DN size
mm
25
25
25
25
25
32
32
32
Kvs value
Torque for max. delta P
Nm
10
10
10
10
10
20
20
20
2,5
4
6,3
10
16
10
16
25
Type
V5434T1010
V5434T1028
V5434T1036
V5434T1044
V5434T1051
V5434T1069
V5434T1077
V5434T1085
2
3
4
H-extensions
H-extension DN25
HE25
H-extension DN32
HE32
5
Accessories
LSU25-22
Soldering socket with gasket and cap nut, DN size 25 mm
LSU25-28
Soldering socket with gasket and cap nut, DN size 32 mm
LSU32-22
Soldering socket with gasket and cap nut, DN size 32 mm
LSU32-28
Soldering socket with gasket and cap nut, DN size 32 mm
LSU32-35
Internal threaded socket with gaskets and cap nut, DN size 25mm
STU25
Internal threaded socket with gaskets and cap nut, DN size 32mm
STU32
M7061E1020
Soldering socket with gasket and cap nut, DN size 25 mm
M7061E1012
LSU25-18
M6061L1027
WTU32
Soldering socket with gasket and cap nut, DN size 25 mm
M6061L1019
Welding socket with gaskets and cap nut, DN size 32 mm
M6061A1021
WTU25
M6061A1013
Welding socket with gaskets and cap nut, DN size25 mm
3-pt
24; 3,5
10
3-pt
24; 3,5
20
3-pt
230; 3,5
10
3-pt
230; 3,5
20
0/2..10V=
24; 2,4
10
0/2..10V=
24; 2,4
20
•
•
•
•
•
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
•
•
•
•
•
•
•
•
–
–
–
–
–
–
–
–
•
•
•
6
7
8
9
Control input signal
Power supply [Vac; VA]
Torque [Nm]
10
V5434T1010
V5434T1028
V5434T1036
V5434T1044
V5434T1051
V5434T1069
V5434T1077
V5434T1085
11
12
13
14
4-13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
4-14
http://europe.hbc.honeywell.com
Frequency inverters
Frequency inverters
Page
1
5-2
2
3
4
5
6
7
8
9
10
11
12
13
14
Frequency inverters
Frequency inverters
1
Inverters economy 0,5..2,2kW, IP20, NXL
Speed and/or torque controller for induction motors. EMC and LVD compliant with external filters.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating, ventilation and air conditioning systems, normally
Low Overload ratings are used. Industrial or process installations normally require High Overload
ratings.
2
Features
• AC choke included for protection against overvoltage
• brake chopper included
• flexible I/O configuration; 1 free slot
• compact housing
• power module with metal chassis for compliance with RFI regulations and safety
• detachable HMI-panel for parameter settings, alarms, start/
stop functions, using a code-number system
• 1 all-round software package included, other packages can be
installed on site
• CE-Mark declaration enclosed in manual
3
4
5
6
7
Power supply
380..500 Volt, 45..66 Hz
Output frequency
0 ... 320 Hz
Frequency resolution
0,01 Hz
Serial communication
optional: Interbus-S, Modbus, Echelon, Profibus
Immunity
EN61800-3 (H) with external filters
Emissions
EN61800-3 (H) with external filters
Safety
EN 50178, CE, UL, C-UL, FI, GOST R
Protection class
IP20
High Overload 380V
High Overload Icont
Low Overload 380V
Low Overload Icont
kW
0,37
0,55
0,75
1,1
1,5
A
1,3
1,9
2,4
3,3
4,3
kW
0,55
0,75
1,1
1,5
2,2
A
1,9
2,4
3,3
4,3
5,4
8
9
10
Dimensions device
(LxWxH)
cm
15; 6; 13
15; 6; 13
17,2; 8,4; 18,4
17,2; 8,4; 18,4
17,2; 8,4; 22
Type
NXL0001V35C1N0
NXL0002V35C1N0
NXL0003V35C1N1
NXL0004V35C1N1
NXL0005V35C1N1
Inverters economy 1,1..30kW, IP21/IP54, NXL
Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally
Low Overload inverters are used. Industrial or process installations normally require High Overload
inverters.
11
Features
12
13
14
5-2
• AC choke included for protection against overvoltage
• brake chopper included
• RFI filter included
• flexible I/O configuration; 1 free slot
• compact housing
• power module with metal chassis for compliance with RFI regulations and safety
• detachable HMI-panel for parameter settings, alarms, start/
stop functions, using a code-number system
• 1 all-round software package included, other packages can be
installed on site
• CE-Mark declaration enclosed in manual
http://europe.hbc.honeywell.com
Frequency inverters
Power supply
380..500 Volt, 45..66 Hz
Output frequency
0 ... 320 Hz
1
Frequency resolution
0,01 Hz
Serial communication
optional: Interbus-S, Modbus, Echelon, Profibus
Immunity
EN61800-3 (H)
Emissions
EN61800-3 (H)
Safety
EN 50178, CE, UL, C-UL, FI, GOST R
High Overload
380V
High Overload
Icont
Low Overload
380V
Low Overload
Icont
Imax
kW
0,75
1,1
1,5
2,2
3
4
5,5
A
2,2
3,3
4,3
5,6
7,6
9
12
kW
1,1
1,5
2,2
3
4
5,5
7,5
A
3,3
4,3
5,6
7,6
9
12
16
A
4,4
5,6
7,2
10,8
14
18
24
7,5
16
11
23
32
11
23
15
31
44
15
31
18,5
38
62
18,5
38
22
46
76
22
46
30
61
90
High Overload
380V
High Overload
Icont
Low Overload
380V
Low Overload
Icont
Imax
kW
0,75
1,1
1,5
2,2
3
4
5,5
A
2,2
3,3
4,3
5,6
7,6
9
12
kW
1,1
1,5
2,2
3
4
5,5
7,5
A
3,3
4,3
5,6
7,6
9
12
16
A
4,4
5,6
7,2
10,8
14
18
24
7,5
16
11
23
32
11
23
15
31
44
15
31
18,5
38
62
18,5
38
22
46
76
22
46
30
61
90
Dimensions
device (LxWxH)
cm
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
21,4; 14,4;
39,1
21,4; 14,4;
39,1
21,4; 14,4;
39,1
23,7; 19,5;
51,9
23,7; 19,5;
51,9
23,7; 19,5;
51,9
Protection
class
Dimensions
device (LxWxH)
cm
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
19; 12,8; 29,2
21,4; 14,4;
39,1
21,4; 14,4;
39,1
21,4; 14,4;
39,1
23,7; 19,5;
51,9
23,7; 19,5;
51,9
23,7; 19,5;
51,9
Protection
class
2
3
Type
IP21
IP21
IP21
IP21
IP21
IP21
IP21
NXL0003V35C2H1
NXL0004V35C2H1
NXL0005V35C2H1
NXL0007V35C2H1
NXL0009V35C2H1
NXL0012V35C2H1
NXL0016V35C2H1
IP21
NXL0023V35C2H1
IP21
NXL0031V35C2H1
IP21
NXL0038V35C2H1
IP21
NXL0046V35C2H1
IP21
NXL0061V35C2H1
Type
4
5
6
7
8
9
IP54
IP54
IP54
IP54
IP54
IP54
IP54
NXL0003V35C5H1
NXL0004V35C5H1
NXL0005V35C5H1
NXL0007V35C5H1
NXL0009V35C5H1
NXL0012V35C5H1
NXL0016V35C5H1
IP54
NXL0023V35C5H1
IP54
NXL0031V35C5H1
IP54
NXL0038V35C5H1
IP54
NXL0046V35C5H1
IP54
NXL0061V35C5H1
10
11
12
13
14
5-3
Frequency inverters
1
Inverters 1,1..110kW, IP21, NXS
Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally
Low Overload inverters are used. Industrial or process installations normally require High Overload
inverters.
2
Features
• AC choke included for protection against overvoltage
• with internal RFI filter
• flexible I/O configuration
• compact housing
• power module with metal chassis for compliance with RFI regulations and safety
• detachable multilingual HMI-panel for parameter settings,
alarms, start/stop functions
• CE-Mark declaration enclosed in manuel
3
4
5
6
7
Power supply
380..500 Volt, 45..66 Hz
Output frequency
0 ... 320 Hz
Frequency resolution
0,01 Hz
Serial communication
optional: Interbus-S, Modbus, Echelon, Profibus
Immunity
EN 50082-1, 2 and EN61800-3
Emissions
EMC level I: EN 50081-2; EMC level C: EN 50081-1, 2 and
EN61800-3
Safety
EN 50178, CE, UL, C-UL, FI, GOST R
Protection class
IP21
Additional description
Models up to 61 A (Low Overload current) supplied with brake
chopper. Over 61 A, brake chopper optional.
High Overload
380V
kW
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
8
9
10
11
12
13
High Overload
Icont
A
2,2
3,1
4
5,4
7
9
12
16
22
31
38
45
61
72
87
105
140
168
Low Overload
380V
kW
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
110
Brake chopper
14
5-4
http://europe.hbc.honeywell.com
Low Overload
Icont
A
3,1
4
5,4
7
9
12
16
22
31
38
45
61
72
87
105
140
168
205
Imax
A
4,4
5,6
7,2
10,8
14
18
24
32
44
62
76
90
122
144
174
210
280
336
Dimensions device (LxWxH)
cm
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
21,5; 14; 38
21,5; 14; 38
21,5; 14; 38
24; 19; 51
24; 19; 51
24; 19; 51
26; 23; 58,5
26; 23; 58,5
26; 23; 58,5
29,5; 30; 74,7
29,5; 30; 74,7
29,5; 30; 74,7
Type
NXS0003V35A2H1
NXS0004V35A2H1
NXS0005V35A2H1
NXS0007V35A2H1
NXS0009V35A2H1
NXS0012V35A2H1
NXS0016V35A2H1
NXS0022V35A2H1
NXS0031V35A2H1
NXS0038V35A2H1
NXS0045V35A2H1
NXS0061V35A2H1
NXS0072V35A2H0
NXS0087V35A2H0
NXS0105V35A2H0
NXS0140V35A2H0
NXS0168V35A2H0
NXS0205V35A2H0
NXBC0072V51
Frequency inverters
1
Inverters 1,1..110kW, IP54, NXS
Speed controller for induction motors, with built-in RFI filters. EMC and LVD compliant.
The Honeywell inverters are suitable for High/Low Overload (constant/variable torque) applications. To control pumps and fans for heating , ventilation and air conditioning systems, normally
Low Overload inverters are used. Industrial or process installations normally require High Overload
inverters.
Features
• AC choke included for protection against overvoltage
• with internal RFI filter
• flexible I/O configuration
• compact housing
• full metal housing for compliance with RFI regulations and
safety
• detachable multilingual HMI-panel for parameter settings,
alarms, start/stop functions
• CE-Mark declaration enclosed in manuel
Power supply
380..500 Volt, 45..66 Hz
Output frequency
0 ... 320 Hz
Frequency resolution
0,01 Hz
Serial communication
optional: Interbus-S, Modbus, Echelon, Profibus
Immunity
EN 50082-1, 2 and EN61800-3
Emissions
EMC level I: EN 50081-2; EMC level C: EN 50081-1, 2 and
EN61800-3
Safety
EN 50178, CE, UL, C-UL, FI, GOST R
IP54
Additional description
Models up to 61 A (Low Overload current) supplied with brake
chopper. Over 61 A, brake chopper optional.
Brake chopper
High Overload
Icont
A
2,2
3,1
4
5,4
7
9
12
16
22
31
38
45
61
72
87
105
140
168
Low Overload
380V
kW
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
110
3
4
5
Protection class
High Overload
380V
kW
0,75
1,1
1,5
2,2
3
4
5,5
7,5
11
15
18,5
22
30
37
45
55
75
90
2
Low Overload
Icont
A
3,1
4
5,4
7
9
12
16
22
31
38
45
61
72
87
105
140
168
205
Imax
A
4,4
5,6
7,2
10,8
14
18
24
32
44
62
76
90
122
144
174
210
280
336
Dimensions device (LxWxH)
cm
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
19; 12,8; 28,5
21,5; 14; 38
21,5; 14; 38
21,5; 14; 38
24; 19; 51
24; 19; 51
24; 19; 51
26; 23; 58,5
26; 23; 58,5
26; 23; 58,5
29,5; 30; 74,7
29,5; 30; 74,7
29,5; 30; 74,7
6
7
Type
8
NXS0003V35A5H1
NXS0004V35A5H1
NXS0005V35A5H1
NXS0007V35A5H1
NXS0009V35A5H1
NXS0012V35A5H1
NXS0016V35A5H1
NXS0022V35A5H1
NXS0031V35A5H1
NXS0038V35A5H1
NXS0045V35A5H1
NXS0061V35A5H1
NXS0072V35A5H0
NXS0087V35A5H0
NXS0105V35A5H0
NXS0140V35A5H0
NXS0168V35A5H0
NXS0205V35A5H0
9
10
11
12
13
NXBC0072V51
14
5-5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
5-6
http://europe.hbc.honeywell.com
Sensors
Sensor Applications
Temperature sensors NTC 20 kohm
Temperature sensors Pt1000
Temperature sensors Balco
R.H. ( + temperature) sensors
IRC/XL10 sensors, Wall modules
Pressure switches
Pressure sensors
Air quality sensors
Miscellaneous
Page
6-2
6-3
6-9
6-14
6-16
6-18
6-22
6-30
6-38
6-40
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Sensor Applications
Sensor Applications
1
Sensor Applications
Outdoor
Air Duct
Room
Temperature
2
3
Pipe
Pipe
Miscella-
RF20
AF20
LF20
(Strap-On)
VF20A
(Immersion)
VF20T
neous
EF20
DRF20-S
DAF20
T7411Axxxx
WPF20A
VF20L
GF20
T7412xxxx
T7416Axxxx
C7068Axxxx
T7414Axxxx
WPF20T
DGF20
T7460A-F
SAF25
WPF20L
T7415Axxxx
T7460H
VF20T
KTF20
T7560H
VF20L
DKF20
S7014A-C
VF20NT
AGF1
VF20LN
4
T7413Axxxx
T7425Axxxx
Humidity &
5
H7508Axxxx H7015Axxxx
Temperature
H7012Axxxx
H7015Bxxxx
Air Quality
CO2 &
H7012Bxxxx
C7110A
C7110C1001
AQS51-KAM
Temperature
Averaging
LON
6
T7560C
C7110D1009
AFF20-L
AQS61-KAM
C7085Axxxx
LF20-L
T7425-L
VF20-L
Differential Pressure
7
DPS200
Switch
DPS400
DPS1000
8
Differential Pressure Trans-
DPS2500
SK, SKV
mitter
DPT
Nominal values
9
Sensing Element
Pt1000
10
NTC20k
Thermistor
1000 Ω @ 0°C
100 Ω @ 0°C
500 Ω @ 23.3°C
20 kΩ @ 25°C
Accuracy
0,3 K + 0,5% ⋅ |t|
0,3 K + 0,5% ⋅ |t|
±1 Ω @ 23.3°C
0,3 K + 1% ⋅ |t-25|
(t in °C)
(t in °C)
≈ 3.85 Ω/K
≈ 0.4 Ω/K
12
13
14
6-2
Balco500
Resistance
Sensitivity
11
Pt100
http://europe.hbc.honeywell.com
(t in °C)
≈ 2 Ω/K
–
Temperature sensors NTC 20 kohm
Temperature sensors NTC 20 kohm
1
Wall modules for heating applications
Room temperature sensor for Excel 10 and Excel 50..600 controllers. With setpoint adjustment,
occupancy extension.
LED functions
2
LED on or blinking in case of bypass, LED functions programmable with Excel 20..600 controllers
Temperature element
NTC20k
Temperature range
-15 ... 40 oC
Setpoint knob
-7 ... 7 oC
Occupancy switch
auto/off/on
3
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Additional description
Models with setpoint potentiometer delivered with 4 setpoint
wheels; white and blue, relative and absolute scale.
Product description
Sensor with setpoint wheel
Sensor with pushbuttons for setpoint adjustment and display
4
Type
T7460H
T7560H
5
6
Room temperature sensor NTC, economy
Protection class
IP30
Temperature element
NTC20k
Temperature range
6 ... 40 oC
Mounting place
internal wall
Housing (HxWxD)
56 mm; 46 mm; 19,3 mm
Wiring terminals
2
Type of terminals
spring
Additional description
T7470A1009 will be delivered as one set of 5 sensors.
7
8
9
Type
T7470A1009
10
Room temperature sensor, NTC
Protection class
IP30
Temperature element
2 x NTC20k
Temperature range
-15 ... 40 oC
Mounting place
internal wall
Housing (HxWxD)
75 mm; 105 mm; 28,5 mm
Wiring terminals
3
11
12
Type
DRF20-S
13
14
6-3
Temperature sensors NTC 20 kohm
1
Room temperature sensor, NTC
Room temperature sensor for MCR controller family.
2
3
Temperature element
NTC20k
Temperature range
10 ... 35 oC
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Wiring terminals
2
Type
RF20
4
Room temperature sensor, setpoint unit, IRC style
Room temperature sensor. Models with remote control point adjustment unit.
5
6
Protection class
IP30
Mounting place
internal wall
Temperature element
NTC20k
Temperature range
0 ... 50 oC
Housing (HxWxD)
130 mm; 80 mm; 34 mm
Wiring terminals
7
2
8
Setpoint knob
o
C
–
Occupancy switch
Fan switch
–
–
Setpoint knob
o
C
- ... +
Occupancy switch
Fan switch
–
–
Setpoint knob
o
C
- ... +
Occupancy switch
Fan switch
on/off
–
Type
T7412A1000
T7412B1008
Wiring terminals
9
3
Type
T7412B1008
10
11
T7412C1006
12
Wiring terminals
4
13
14
6-4
http://europe.hbc.honeywell.com
Type
T7412C1006
Temperature sensors NTC 20 kohm
T7412D1004
Wiring terminals
4
Setpoint knob
o
C
- ... +
Occupancy switch
Fan switch
–
auto/off/1/2/3
1
Type
T7412D1004
2
3
4
T7412E....
Wiring terminals
6
5
Setpoint knob
o
C
–
–
Occupancy switch
Fan switch
–
–
–
–
Type
T7412E1001
T7412E1027
5
6
7
Water temperature sensor, NTC
8
Water temperature sensor with well or strap-on.
Protection class
IP52 for immersion types, IP30 for strap-on types
Immersion with well
Temperature
element
NTC20k
NTC20k
NTC20k
NTC20k
2 x NTC20k
2 x NTC20k
Temperature
range
o
C
-25 ... 130
-25 ... 150
-25 ... 130
-25 ... 150
-25 ... 130
-25 ... 130
Mounting
place
Immersion
well material
Immersion
well thread
in pipe
in pipe
in pipe
in pipe
in pipe
in pipe
copper
steel
copper
steel
copper
copper
R1/2"
R1/2"
R1/2"
R1/2"
R1/2"
R1/2"
Temperature
range
o
C
0 ... 110
0 ... 110
Mounting
place
Immersion
well material
Immersion
well thread
strap on pipe
strap on pipe
–
–
–
–
Immersion
depth
mm
135
135
300
300
135
300
Wiring terminals
Immersion
depth
mm
–
–
Wiring terminals
2
2
2
2
3
3
9
Type
VF20T
VF20NT
VF20L
VF20LN
WPF20T
WPF20L
10
11
Strap-on
Temperature
element
NTC20k
2 x NTC20k
2
4
Type
12
VF20A
WPF20A
13
14
6-5
Temperature sensors NTC 20 kohm
1
Water temperature sensor NTC, fast reaction time
Sensor for direct mounting in pipe, G1/2" connection.
For water temperature measurement in district heating or hot water supply.
2
3
Protection class
IP65
Temperature element
NTC20k fast
Temperature range
-20 ... 140 oC
Mounting place
in pipe
Cable length
2,5 m
Additional description
Reaction time max. 2 sec. Sensing material steel 1.4571. Immersion depth adjustable.
4
Immersion depth
mm
max. 75
max. 220
max. 300
5
Sensing element (dia x L)
mm; mm
4; 25
4; 170
4; 250
Type
T7425A1005
T7425A1013
T7425A1021
Water temperature sensor NTC, cable type
6
Watertight temperature sensor with sensor cartridge.
7
8
Protection class
IP62
Temperature range
-20 ... 110 oC
Mounting place
universal
Immersion depth
min. 50 mm
Applicable well length
135 mm
Sensing element (dia x L)
6,5 mm; 50 mm
Cable length
2m
Additional description
KTF20-B (bulk of 50 sensors of Type KTF20)
9
Temperature element
NTC20k
NTC20k
2 x NTC20k
10
Wiring terminals
2
2
3
Type
KTF20
KTF20-B
DKF20
Wells
11
Copper well 135 mm G1/2", internal diameter 7 mm
VFHT
Steel well 135 mm G1/2", internal diameter 7 mm
VFNT
Outdoor, strap-on temperature sensor, NTC
12
13
Protection class
IP65
Temperature element
NTC20k
Temperature range
-30 ... 70 oC
Mounting place
outdoor/strap-on
Wiring terminals
2
Cable length
1m
14
Type
T7414C1012
6-6
http://europe.hbc.honeywell.com
Temperature sensors NTC 20 kohm
1
Outdoor temperature sensor NTC
Mounting place
Temperature element
NTC20k
2 x NTC20k
wall outside
Temperature
range
o
C
-40 ... 60
-40 ... 60
Housing (HxWxD)
Wiring terminals
Approvals
Protection class
mm; mm; mm
95; 65; 70
95; 65; 70
2
4
–
–
IP30
IP30
2
Type
3
AF20
DAF20
4
T7416A1022
Temperature element
NTC20k
Temperature
range
oC
-40 ... 70
Housing (HxWxD)
Wiring terminals
Approvals
Protection class
mm; mm; mm
72; 49; 37
2
IEC751 class B
IP54
Type
5
T7416A1022
6
7
Air duct temperature sensor, NTC
Protection class
IP54
Temperature element
NTC20k
Temperature range
-20 ... 100 oC
Mounting place
air duct
Immersion depth
280 mm
Wiring terminals
2
8
9
Type
LF20
10
Air duct temperature sensor, average measurement
11
Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four
rod clips with screws.
For application in ducts where large temperature gradients can occur.
Temperature element
4 x NTC20k
Temperature range
-30 ... 70 oC
Mounting place
air duct
12
Wiring terminals
2
Additional description
The 3 meters flexible rod has four sensors positioned along the
length of the rod.
13
Type
C7085A1014
14
6-7
Temperature sensors NTC 20 kohm
1
Unit temperature sensor
Unit temperature sensor.
Mounting place
2
inside unit
Temperature element
NTC20k
Temperature range
0 ... 40 oC
Wiring terminals
2
3
Cable length
m
1,5
5
4
Type
C7068A1007
C7068A1007-5M
Earth temperature sensor, NTC
5
For use in greenhouses and similar applications
Protection class
6
7
IP62
Temperature element
NTC20k
Temperature range
-20 ... 34 oC
Mounting place
greenhouse, earth
Wiring terminals
2
Cable length
5m
Type
EF20
8
Damp-proof temperature sensor, NTC
for use in greenhouses and similar applications
9
10
Approvals
IEC144
Protection class
IP30
Temperature range
-20 ... 30 oC
Mounting place
greenhouse, air
Cable length
5m
Temperature element
NTC20k
2 x NTC20k
11
12
13
14
6-8
http://europe.hbc.honeywell.com
Wiring terminals
2
3
Type
GF20
DGF20
Temperature sensors Pt1000
Temperature sensors Pt1000
1
Room temperature sensor, setpoint unit
Room temperature sensor. Models with remote control point adjustment unit.
Mounting
internal wall
Approvals
IEC751 Class B
Protection class
IP30
Temperature element
Pt1000
Temperature range
0 ... 50 oC
Housing (HxWxD)
130 mm; 80 mm; 34 mm
Wiring terminals
2
2
3
Setpoint knob
oC
–
Occupancy switch
Setpoint knob
oC
- ... +
- ... +
Occupancy switch
–
Type
4
T7412A1018
T7412B1016
Wiring terminals
4
3
–
–
5
Type
T7412B1016
T7412B1057
6
7
8
T7412B1040
Wiring terminals
5
Setpoint knob
oC
-15 ... 30
Occupancy switch
–
Type
9
T7412B1040
10
11
T7412C1030
Wiring terminals
4
Setpoint knob
o
C
- ... +
Occupancy switch
on/off
Type
12
T7412C1030
13
14
6-9
Temperature sensors Pt1000
1
Water temperature sensor, PTC
Water immersion temperature sensor with or without well.
Approvals
2
3
IEC751 class B
Protection class
IP54
Temperature element
Pt1000
Wiring terminals
2
Temperature range
Mounting place Immersion well mate- Immersion well thread
rial
o
C
-25 ... 130
-25 ... 150
-25 ... 150
4
in pipe
in well
in well
copper
–
–
R1/2"
–
–
Immersion depth
mm
135
max. 135
max. 300
Type
T7413A1009
T7413A1041
T7413A1058
Wells
5
6
Copper well 135 mm G1/2", internal diameter 7 mm
VFHT
Steel well 135 mm G1/2", internal diameter 7 mm
VFNT
Copper well 300 mm G1/2", internal diameter 7 mm
VFL
Steel well 300 mm G1/2", internal diameter 7 mm
VFLN
Water temperature sensor PTC, strap-on
7
Approvals
8
9
IEC751 class B
Protection class
IP54
Temperature element
Pt1000
Temperature range
0 ... 110 oC
Mounting place
strap on pipe
Wiring terminals
2
Type
T7414A1008
10
11
12
13
14
6-10
http://europe.hbc.honeywell.com
Temperature sensors Pt1000
1
Water temperature sensor Pt1000, fast reaction time
Sensor for direct mounting in pipe, G1/2" connection.
For water temperature measurement in hot water supply, solar panels etc.
Protection class
IP65
Temperature element
Pt1000 fast
Temperature range
-20 ... 300 oC
Mounting place
in pipe
2
3
Cable length
2,5 m
Additional description
Reaction time max. 2 sec. Sensing material steel 1.4571. Immersion depth adjustable.
Immersion depth
mm
max. 75
max. 220
Sensing element (dia x L)
mm; mm
4; 75
4; 220
4
Type
T7425B1011
T7425B1029
5
Water temperature sensor PTC, cable type
Approvals
IEC751 class B
Protection class
IP54
Temperature element
Pt1000
Mounting place
universal
Immersion depth
min. 50 mm
Applicable well length
135 mm
Sensing element (dia x L)
6 mm; 50 mm
Wiring terminals
2
Cable length
2,5 m
6
7
8
Temperature range
oC
-20 ... 100
-20 ... 300
9
Type
T7415A1007
T7415A1015
Copper well 135 mm G1/2", internal diameter 7 mm
VFHT
Steel well 135 mm G1/2", internal diameter 7 mm
VFNT
10
11
12
13
14
6-11
Temperature sensors Pt1000
1
Outdoor, strap-on temperature sensor, PTC
Approvals
2
3
IEC751 class B
Protection class
IP65
Temperature element
Pt1000
Temperature range
-30 ... 70 oC
Mounting place
outdoor/strap-on
Wiring terminals
2
Cable length
1m
Type
T7414C1004
4
Outdoor temperature sensor, PTC
5
6
7
Approvals
IEC751 class B
Protection class
IP54
Temperature element
Pt1000
Temperature range
-40 ... 70 oC
Mounting place
wall outside
Housing (HxWxD)
72 mm; 49 mm; 37 mm
Wiring terminals
2
Type
T7416A1014
8
Air duct temperature sensor, PTC
9
10
Approvals
IEC751 class B
Protection class
housing IP54, pipe IP20
Temperature element
Pt1000
Temperature range
-40 ... 80 oC
Mounting place
air duct
Wiring terminals
2
11
Immersion depth
mm
135
300
12
13
14
6-12
http://europe.hbc.honeywell.com
Type
T7411A1001
T7411A1019
Temperature sensors Pt1000
1
Air duct temperature sensor, average measurement
Averaging temperature sensor, with wall socket, flexible rod, a 0,5 m long connector cable and four
rod clips with screws.
For application in ducts where large temperature gradients can occur.
Temperature element
4 x Pt1000
Temperature range
-30 ... 70 oC
Mounting place
air duct
2
3
Wiring terminals
2
Additional description
The 3 meters flexible rod has four sensors positioned along the
length of the rod.
4
Type
C7085A1006
5
Flue gas temperature sensor, PTC
Steel plug in temperature sensor with mounting flange.
For flue gas temperature measurement.
Temperature element
Pt1000
Temperature range
50 ... 600 oC
Mounting place
flue gas vent
Immersion depth
120 mm
Cable length
1m
Additional description
Supplied with electrical cable with steel casing.
6
7
Type
AGF1
8
9
10
11
12
13
14
6-13
Temperature sensors Balco
Temperature sensors Balco
1
Room temperature sensor, setpoint unit
Room temperature sensor. Models with remote control point adjustment unit.
2
3
Protection class
IP30
Mounting place
internal wall
Temperature element
Balco500
Temperature range
0 ... 50 oC
Housing (HxWxD)
130 mm; 80 mm; 34 mm
Wiring terminals
4
2
Setpoint knob
o
C
–
Type
Setpoint knob
oC
-15 ... 30
Type
T7412A1026
T7412B1024
5
Wiring terminals
5
T7412B1024
6
7
8
Water temperature sensor, Balco
Immersion sensor with well.
9
Protection class
10
11
IP54
Temperature element
Balco500
Temperature range
-40 ... 120 oC
Mounting place
in pipe
Immersion well material
copper
Immersion well thread
R1/2"
Immersion depth
95 mm
Wiring terminals
2
Type
L7087A1053
12
Steel well
13
14
6-14
http://europe.hbc.honeywell.com
Y103755B
Temperature sensors Balco
1
Outdoor temperature sensor, Balco
Temperature element
Balco500
Temperature range
-40 ... 50 oC
Mounting place
wall outside
Housing (dia x D)
71 mm; 43 mm
Wiring terminals
2
2
3
Type
T7036A1022
4
Air duct temperature sensor, Balco
Protection class
IP42
Temperature element
Balco500
Temperature range
-40 ... 130 oC
Mounting place
air duct
Wiring terminals
2
5
6
Immersion depth
mm
125
450
Type
7
L7087A1046
L7087A1061
8
9
10
11
12
13
14
6-15
R.H. ( + temperature) sensors
R.H. ( + temperature) sensors
1
Wall module with temperature and R.H. sensor
2
3
4
Temperature element
NTC20k
Temperature range
10 ... 40 oC
R.H. range
5 ... 90 %rh
R.H. sensing element
capacitive
R.H. output signal
0..10V=
Power supply
24 Vacdc; 0,15 VA
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Wiring terminals
5
Type
T7560C1006
5
Room R.H.- and temperature sensor
Combined Room Humidity and Temperature Sensor with various sensor elements
6
7
8
Approvals
IEC751 class B for Pt1000 sensor
Protection class
IP30
R.H. range
5 ... 95 %rh
R.H. sensing element
capacitive
R.H. output signal
0..1/10V=
Power supply
24 Vac; 0,48 VA
Mounting place
internal wall
Housing (HxWxD)
130 mm; 80 mm; 34 mm
Temperature element
9
–
Balco500
Pt1000
NTC20k
10
11
12
13
14
6-16
http://europe.hbc.honeywell.com
Temperature range
o
C
–
0 ... 50
0 ... 50
0 ... 50
Wiring terminals
4
6
6
6
Type
H7012A1009
H7012B1015
H7012B1007
H7012B1023
R.H. ( + temperature) sensors
1
Outdoor R.H.- and temperature sensor
Protection class
IP33
Temperature range
-30 ... 50 oC
R.H. range
5 ... 95 %rh
R.H. sensing element
capacitive
R.H. output signal
0..1/10V=
Power supply
24 Vac; 0,48 VA
Mounting place
wall outside
Housing (HxWxD)
172 mm; 132 mm; 60 mm
Wiring terminals
6
2
3
4
Temperature element
Balco500
Pt1000
NTC20k
Type
H7508A1034
H7508A1026
H7508A1042
5
6
Air duct R.H.- and temperature sensor
Protection class
IP54
R.H. range
5 ... 95 %rh
R.H. sensing element
capacitive
R.H. output signal
0..1/10V=
Power supply
24 Vac; 0,48 VA
Mounting place
air duct
Immersion depth
235 mm
Temperature element
–
Balco500
Pt1000
NTC20k
Temperature range
o
C
–
-30 ... 70
-30 ... 70
-30 ... 70
7
8
Wiring terminals
5
7
7
7
Type
9
H7015A1006
H7015B1012
H7015B1004
H7015B1020
10
11
12
13
14
6-17
IRC/XL10 sensors, Wall modules
IRC/XL10 sensors, Wall modules
1
Room temperature sensor, setpoint unit, IRC style
Room temperature sensor. Models with remote control point adjustment unit.
2
3
Protection class
IP30
Mounting place
internal wall
Temperature element
NTC20k
Temperature range
0 ... 50 oC
Housing (HxWxD)
130 mm; 80 mm; 34 mm
Wiring terminals
4
2
Setpoint knob
o
C
–
Occupancy switch
Fan switch
–
–
Setpoint knob
oC
- ... +
Occupancy switch
Fan switch
–
–
Setpoint knob
oC
- ... +
Occupancy switch
Fan switch
on/off
–
Type
T7412A1000
T7412B1008
5
Wiring terminals
3
Type
T7412B1008
6
7
8
T7412C1006
Wiring terminals
9
4
10
11
12
13
14
6-18
http://europe.hbc.honeywell.com
Type
T7412C1006
IRC/XL10 sensors, Wall modules
T7412D1004
Wiring terminals
4
Setpoint knob
o
C
- ... +
Occupancy switch
Fan switch
–
auto/off/1/2/3
1
Type
T7412D1004
2
3
4
T7412E....
Wiring terminals
6
5
Setpoint knob
o
C
–
–
Occupancy switch
Fan switch
–
–
–
–
Type
T7412E1001
T7412E1027
5
6
7
Remote setpoint adjustment unit for IRC or XL10
8
Remote setpoint adjustment unit.
Mounting
fancoil unit
Protection class
IP30
Setpoint knob
- ... + oC
Cable length
2m
Housing (HxWxD)
75 mm; 70 mm; 22 mm
Wiring terminals
2
9
Fan switch
–
Model
for XL IRC
Type
S7014A1004
Fan switch
auto/off/1/2/3
auto/off/1/2/3
Model
for XL IRC
for XL10
Type
S7014B1000
S7014C1009
10
S7014B, S7014C
Wiring terminals
3
3
11
12
13
14
6-19
IRC/XL10 sensors, Wall modules
1
Wall modules for EXCEL 5000 controllers
Room temperature sensor for Excel 10 and Excel 50..600 controllers. Models available with setpoint adjustment, occupancy extension and fan switch.
2
LED functions
3
Temperature element
NTC20k
Temperature range
10 ... 35 oC
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Additional description
Models with setpoint potentiometer delivered with 4 setpoint
wheels; white and blue, relative and absolute scale.
4
Setpoint knob
o
C
–
5
LED on or blinking in case of bypass, LED functions programmable with Excel 20..600 controllers
Extra setp. knob
o
C
–
Occupancy switch
Fan switch
Wiring terminals
–
–
2
Extra setp. knob
oC
12 ... 30
Occupancy switch
Fan switch
Wiring terminals
–
–
3
Extra setp. knob
o
C
12 ... 30
Occupancy switch
Fan switch
Wiring terminals
auto/bypass
–
7
Extra setp. knob
oC
12 ... 30
Occupancy switch
Fan switch
Wiring terminals
–
auto/off/1/2/3
4
Extra setp. knob
o
C
12 ... 30
Occupancy switch
Fan switch
Wiring terminals
auto/bypass
auto/off/on
7
Type
T7460A1001
T7460B1009
Setpoint knob
oC
-5 ... 5
6
Type
T7460B1009
7
T7460C1007
8
Setpoint knob
o
C
-5 ... 5
Type
T7460C1007
9
10
T7460D1005
Setpoint knob
oC
-5 ... 5
11
Type
T7460D1005
12
T7460E1002
13
Setpoint knob
o
C
-5 ... 5
14
6-20
http://europe.hbc.honeywell.com
Type
T7460E1002
IRC/XL10 sensors, Wall modules
T7460F1000
Setpoint knob
o
C
-5 ... 5
Extra setp. knob
o
C
12 ... 30
Occupancy switch
Fan switch
Wiring terminals
auto/bypass
auto/off/1/2/3
7
1
Type
T7460F1000
2
3
LON connection board
T7460LONJACK
Setpoint range limiter
T7460LIMITER
4
5
6
Wall modules for EXCEL 5000 controllers, with display
Room temperature sensor with digital display, for Excel 10 and Excel 50..600 controllers. With setpoint adjustment, occupancy extension, fan speed button and on/off button. Model with R.H.-sensor.
Display functions
room temperature, setpoint temperature, occupancy status, fan
speed status
Temperature element
NTC20k
Temperature range
10 ... 40 oC
Setpoint knob
-5 ... 5 oC
Extra setp. knob
12 ... 30
Occupancy switch
on/off
7
8
oC
Fan switch
configurable
Power supply
24 Vac; 2 VA
9
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Additional description
Tool-free configuration:
• number of fan speeds
• relative / absolute setpoint
• enable/disable space temperature display
• centigrade/fahrenheit
10
11
R.H. range
%rh
–
–
–
R.H. sensing element
R.H. output signal
Wiring terminals
Model
–
–
–
–
–
–
7
7
7
5 ... 90
5 ... 90
5 ... 90
capacitive
capacitive
capacitive
0..10V=
0..10V=
0..10V=
8
8
8
blue knobs/wheel
white knobs/wheel
white knobs/wheel/
fahrenheit
blue knobs/wheel
white knobs/wheel
white knobs/wheel/
fahrenheit
Type
T7560A1000
T7560A1026
T7560A1018
12
T7560B1008
T7560B1024
T7560B1016
13
LON connection board
T7460LONJACK
Blind cover for T7560 knobs (50 pieces)
T7560BLINDS
6-21
14
Pressure switches
Pressure switches
1
Pressure switch for non-aggressive liquids and gases
For overpressure monitoring of non-aggressive liquids and gaseous media.
2
3
Kind of pressure
overpressure, relative
Pressure connection
internal thread G1/4, external thread G1/2
Electrical connection
Plug DIN 43650
Protection class
IP54
Housing material
rugged housing of seawater resistant aluminium die casting GD Al
Si 12.
Media temperature
-25 ... 70 oC
Media temp. limit
temperatures up to 85 oC are allowable for short periods. Higher
temperatures are possible, provided that the limit is safeguarded
by suitable measures (e.g. water tube trap, see Accessories for
Pressure Switches / Transmitters)
Ambient temperature
-25 ... 70 oC
Ambient temp. limit
at temperatures below 0 oC, ensure that no water condensation
can arise in the sensor and in the switching device
Switch function/capacity
SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Optional functions
add the type numbers below to the listed type numbers for extra
functionality as described
• -301: terminal connection housing, IP65
• -307: two microswitches, switching in parallel or in succession,
fixed switching interval, terminal connection case, IP65
• -217: two microswitches, 1 plug, switching in succession, adjustable switching interval
• -213: gold-plated contacts, switching capacity: max. 24 Vdc,
100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
• -351: protection class IP65 and switching housing with surface
protection (chemical version)
• -513: gold-plated contacts, switching differential permanent,
IP65, switching capacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2
mA; suitable isolating switching amplifier: Ex011 (see Accessories for Pressure Switches / Transmitters), degree of protection
EEx-i
4
5
6
7
8
9
10
11
12
13
14
6-22
http://europe.hbc.honeywell.com
Pressure switches
1
Fixed pressure hysteresis
Pressure adjustment
range
bar
0,04 ... 0,25
0,1 ... 0,6
0,2 ... 1,6
0,2 ... 2,5
0,5 ... 6
0,5 ... 6
1 ... 10
3 ... 16
4 ... 25
8 ... 40
16 ... 63
0,04 ... 0,25
Adjustable switching
differential
bar
–
–
–
–
–
–
–
–
–
–
–
–
Switching differential
Max. pressure
bar
0,03
0,04
0,04
0,1
0,15
0,25
0,3
0,5
1
1,3
2
0,03
bar
6
6
6
16
16
25
25
25
60
60
130
6
Switching differential
Max. pressure
bar
–
–
–
–
–
–
–
–
–
–
bar
6
6
6
16
16
25
25
60
60
130
Sensing element material
Copper + Brass
Copper + Brass
Copper + Brass
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
Type
2
DCM025
DCM06
DCM1
DCM3
DCM6
DCM625
DCM10
DCM16
DCM25
DCM40
DCM63
DNM025
3
4
5
Adjustable pressure hysteresis
Pressure adjustment
range
bar
0,04 ... 0,25
0,1 ... 0,6
0,2 ... 1,6
0,2 ... 2,5
0,5 ... 6
1 ... 10
3 ... 16
4 ... 25
8 ... 40
16 ... 63
Adjustable switching
differential
bar
0,03 ... 0,4
0,04 ... 0,5
0,07 ... 0,55
0,15 ... 1,5
0,25 ... 2
0,5 ... 2,8
0,7 ... 3,5
1,3 ... 6
2,6 ... 6,6
3 ... 10
Sensing element material
Copper + Brass
Copper + Brass
Copper + Brass
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
1.4104 + 1.4571
Syphon for high temperature, steel, U-shape (for more accessories, see Accessories
for Pressure Switches / Transmitters)
Type
6
DCMV025
DCMV06
DCMV1
DCMV3
DCMV6
DCMV10
DCMV16
DCMV25
DCMV40
DCMV63
7
8
9
U430B
10
11
12
13
14
6-23
Pressure switches
1
Differential pressure switch for liquids and gases
For flow monitoring and differential pressure control of steam, gas, hot/cold water and automatic
checking of filter plant.
2
3
4
5
Kind of pressure
differential pressure, relative
Pressure connection
internal thread G1/4
Electrical connection
Plug DIN 43650
Protection class
IP54
Housing material
rugged housing of seawater resistant aluminium die casting GD Al
Si 12
Media temperature
-25 ... 70 oC
Media temp. limit
temperatures up to 85 oC are allowable for short periods. Higher
temperatures are possible, provided that the limit is safeguarded
by suitable measures (e.g. water tube trap, see Accessories for
Pressure Switches / Transmitters)
Ambient temperature
-25 ... 70 oC
Ambient temp. limit
at temperatures below 0 oC, ensure that no water condensation
can arise in the sensor and in the switching device
Switch function/capacity
SPDT Microswitch; capacity 5 A inductive, 8 A resistive
Optional functions
add the type numbers below to the listed type numbers for extra
functinality as described
• -301: terminal connection housing, IP65
• -205: maximum limiter with reclosing lock-out, interlocking
with increasing pressure
• -206: Minimum limiter with reclosing lock-out, interlocking with
falling pressure
• -307: two microswitches, switching in parallel or in succession,
fixed switching interval, terminal connection case, IP65 (with
the exception of DDCM252, 662, 1602, 6002)
• -217: two microswitches, 1 plug, switching in succession, adjustable switching interval (with the exception of DDCM252,
662, 1602, 6002)
• -213: gold-plated contacts, switching capacity: max. 24 Vdc,
100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
• -351: protection class IP65 and switching housing with surface
protection (chemical version)
• -513: gold-plated contacts, switching differential permanent,
IP65, switching c apacity: max. 24 Vdc, 100 mA, min. 5 Vdc, 2
mA; suitable isolating switching amplifier: Ex011 (see Accessories for Pressure Switches / Transmitters), degree of protection
EEx-i
6
7
8
9
10
11
Pressure adjustment range
bar
0,004 ... 0,025
0,01 ... 0,06
0,02 ... 0,16
0,1 ... 0,6
-0,1 ... 0,4
0,2 ... 1,6
1 ... 4
0,5 ... 6
3 ... 16
12
13
14
Switching differential
bar
0,002
0,015
0,02
0,035
0,15
0,13
0,2
0,2
0,6
Max. pressure
bar
0,5
1,5
3
3
15
15
25
15
25
Sensing element material
Perbunan + Aluminium
Perbunan + Aluminium
Perbunan + Aluminium
Perbunan + Aluminium
1.4305 + 1.4571
1.4305 + 1.4571
1.4305 + 1.4571
1.4305 + 1.4571
1.4305 + 1.4571
Syphon for high temperature, steel, U-shape (for more accessories, see Accessories
for Pressure Switches / Transmitters)
6-24
http://europe.hbc.honeywell.com
Type
DDCM252
DDCM662
DDCM1602
DDCM6002
DDCM014
DDCM1
DDCM4
DDCM6
DDCM16
U430B
Pressure switches
1
Differential pressure switch for air
Filter monitor or flow switch for air, non-combustible, non agressive gases in air conditioning and
ventilating installations.
2
Kind of pressure
overpressure, relative
Pressure connection
plastic connection piece for 5 mm (internal) hose
Electrical connection
AMP connector 6,3x0,8 (DIN 46244) or screw terminals
Protection class
IP54
3
Sensing element material
ABS + Silicon
Media temperature
-20 ... 85 oC
Ambient temperature
-20 ... 85 oC
Switch function/capacity
SPDT switch 240 Vac; 1,5 A (0.4)A
Certificates
CE0085AR0013 according DIN EN 1854
Max. pressure
50 mbar
Additional description
Accessories supplied with pressure switch: 2 m silicon hose, 2
connection pieces with mounting screws, 2 self tapping screws
for mounting on housing, 3 screw terminals for electrical connection.
Pressure adjustment range
mbar
0,2 ... 2
0,4 ... 4
0,5 ... 5
2 ... 10
5 ... 25
Switching differential
mbar
0,1
0,2
0,2
1
1,5
4
5
Type
6
DPS200
DPS400
DPS500
DPS1000
DPS2500
7
Accessories
L-shaped bracket for installation turned by 90o, e.g. in the ceiling area
8
DPSL
9
10
11
12
13
14
6-25
Pressure switches
1
Pressure monitor for hot water, steam, burnable gases and liquid fuels
For overpressure monitoring of steam, hot water, burnable gases, liquid fuels.
2
3
4
5
6
Kind of pressure
overpressure, relative
Pressure connection
internal thread G1/4, external thread G1/2
Electrical connection
Plug DIN 43650
Protection class
IP54
Housing material
rugged housing of seawater resistant aluminium die casting GD Al
Si 12
Sensing element material
1.4104 + 1.4571
Media temperature
-25 ... 70 oC
Media temp. limit
temperatures up to 85 oC are allowable for short periods. Higher
temperatures are possible, provided that the limit is safeguarded
by suitable measures (e.g. water tube trap, see Accessories for
Pressure Switches / Transmitters)
Ambient temperature
-25 ... 70 oC
Ambient temp. limit
at temperatures below 0 oC, ensure that no water condensation
can arise in the sensor and in the switching device
Switch function/capacity
SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Mechanical lock/reset
with special function possible
Optional functions
add the type numbers below to the listed type numbers for extra
functionality as described
• -213: gold-plated contacts, switching capacity: max. 24 Vdc,
100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
• -301: terminal connection housing, IP65
• -513: Gold-plated contacts, single-pole switch-over. Switching differential permanent. IP65. Switching capacity: max. 24
Vdc, 100 mA, min. 5 Vdc, 2 mA, suitable isolating switching
amplifier: Ex011 (see Accessories for Pressure Switches /
Transmitters), degree of protection EEx-i
• -574: Normally closed contact with resistance combination for
minimum pressure monitoring. Gold-plated contacts. Housing
with surface protection (chemical version), IP65
• -575: Normally closed contact with reclosing lock-out resistance combination for minimum pressure monitoring. Housing
with surface protection (chemical version), IP65
• -576: Normally closed contact with resistance combination for
maximum pressure monitoring. Gold-plated contacts. Housing
with surface protection (chemical version), IP65
• -577: Normally closed contact with reclosing lock-out and resistance combination for maximum pressure monitoring.
Housing with surface protection (chemical version), IP65
7
8
9
10
11
Certificates
12
• TUEV-DWFS (SDBFS) 00-281 according VdTUEV Memorandum Pressure 100/1, Issue 4.83
• NG-4347AQ1411 according to DIN 3398, Part 3, Issue 11.92
• 3C0282000 according to DIN 3398, Part 4, Issue 10.86
• CE0035BN004 according Directive 97/23/EC (Module B + D)
13
14
6-26
http://europe.hbc.honeywell.com
Pressure switches
1
Fixed pressure hysteresis
Pressure adjustment
range
Adjustable switching
differential
Switching differential
Max. pressure
bar
0,1 ... 0,6
0,2 ... 1,6
0,2 ... 2,5
0,5 ... 6
0,5 ... 6
3 ... 16
4 ... 25
8 ... 40
bar
–
–
–
–
–
–
–
–
bar
0,04
0,06
0,1
0,2
0,25
0,5
1
1,3
bar
6
6
16
16
25
25
63
63
Allowable max. gaspressure
(DIN3398P3)
bar
6
6
10
10
20
20
50
50
Type
Allowable max. gaspressure
(DIN3398P3)
bar
6
6
10
10
20
20
50
50
Type
2
DWR06
DWR1
DWR3
DWR6
DWR625
DWR16
DWR25
DWR40
3
4
Adjustable pressure hysteresis
Pressure adjustment
range
Adjustable switching
differential
Switching differential
Max. pressure
bar
0,1 ... 0,6
0,2 ... 1,6
0,2 ... 2,5
0,5 ... 6
0,5 ... 6
3 ... 16
4 ... 25
8 ... 40
bar
0,08 ... 0,5
0,15 ... 0,6
0,17 ... 1,2
0,3 ... 1,4
0,4 ... 2,5
0,75 ... 3,15
1,3 ... 6
2,3 ... 6,6
bar
–
–
–
–
–
–
–
–
bar
6
6
16
16
25
25
63
63
Syphon for high temperature, steel, U-shape (for more accessories, see Accessories
for Pressure Switches / Transmitters)
5
DWR06-203
DWR1-203
DWR3-203
DWR6-203
DWR625-203
DWR16-203
DWR25-203
DWR40-203
6
7
8
U430B
9
10
11
12
13
14
6-27
Pressure switches
1
Minimum pressure limiter for hot water, steam, fuel, gas.
For minimum-pressure detection of steam, hot water, burnable gases, liquid fuels.
2
3
4
5
Kind of pressure
overpressure, relative
Pressure connection
internal thread G1/4, external thread G1/2
Electrical connection
Plug DIN 43650
Protection class
IP54
Housing material
rugged housing of seawater resistant aluminium die casting GD Al
Si 12
Sensing element material
1.4104 + 1.4571
Media temperature
-25 ... 70 oC
Media temp. limit
temperatures up to 85 oC are allowable for short periods. Higher
temperatures are possible, provided that the limit is safeguarded
by suitable measures (e.g. water tube trap, see Accessories for
Pressure Switches / Transmitters)
Ambient temperature
-25 ... 70 oC
Ambient temp. limit
at temperatures below 0 oC, ensure that no water condensation
can arise in the sensor and in the switching device
Switch function/capacity
SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates
6
7
• TUEV.SDBF.02-309 according VdTUEV Memorandum Pressure 100/1, Issue 4.83
• NG-4347AQ1411 according DIN 3398, part 3, issue 11.92
• 3C0282000 according to DIN 3398, Part 4, Issue 10.86
• CE0035BN0004 according Directive 97/23EC (Module B + D)
Pressure interlock/Reset
8
9
10
minimum press./button
Pressure adjustment range
Max. pressure
bar
0,1 ... 0,6
0,2 ... 1,6
0,2 ... 2,5
0,5 ... 6
0,5 ... 6
3 ... 16
4 ... 25
8 ... 40
bar
6
6
16
16
25
25
63
63
Allowable max. gas-pressure
(DIN3398P3)
bar
6
6
10
10
20
20
50
50
Syphon for high temperature, steel, U-shape, for more accessories, see Accessories
for Pressure Switches / Transmitters)
11
12
13
14
6-28
http://europe.hbc.honeywell.com
Type
DWR06-206
DWR1-206
DWR3-206
DWR6-206
DWR625-206
DWR16-206
DWR25-206
DWR40-206
U430B
Pressure switches
1
Maximum pressure limiter of 'special construction'
Maximum pressure limiter with selfmonitoring sensor and internal relock
For steam and hot water.
2
Kind of pressure
overpressure, relative
Pressure connection
internal thread G1/4, external thread G1/2
Electrical connection
Plug DIN 43650
Protection class
IP54
Housing material
rugged housing of seawater resistant aluminium die casting GD Al
Si 12.
Sensing element material
1.4104 + 1.4571
Media temperature
-20 ... 70 oC
Media temp. limit
temperatures up to 85 oC are allowable for short periods. Higher
temperatures are possible, provided that the limit is safeguarded
by suitable measures (e.g. water tube trap, see Accessories for
Pressure Switches / Transmitters)
Ambient temperature
-20 ... 70 oC
Ambient temp. limit
at temperatures below 0 oC, ensure that no water condensation
can arise in the sensor and in the switching device
Switch function/capacity
SPDT Microswitch 250 Vac; capacity 5 A inductive, 8 A resistive
Certificates
Pressure interlock/Reset
3
4
5
6
• TUEV-SDB-99-134 according VdTUEV Memorandum Pressure 100/1
• CE0035BN0007 according Directive 97/23/EC (Module B + D)
maximum press./button
7
Pressure adjustment range
bar
0,2 ... 1,6
0,4 ... 2,5
1,2 ... 6
1,2 ... 6
3 ... 16
6 ... 32
Switching differential
bar
0,12
0,15
0,4
0,6
0,8
3
Max. pressure
bar
5
5
10
20
20
45
Syphon for high temperature, steel, U-shape (for more accessories, see Accessories
for Pressure Switches / Transmitters)
Type
SDBAM1
SDBAM2,5
SDBAM6
SDBAM625
SDBAM16
SDBAM32
8
9
U430B
10
11
12
13
14
6-29
Pressure sensors
Pressure sensors
1
Electronic Pressure switch for liquides with high viscosity or roiled liquids, SmartPress
Electronic Pressure switch, with LCD display for the field of plant construction, fluidics, process
technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
• all models: switch output open collector; 14..36 Vdc, 250 mA
• PST -series: transmitter output; 0..10 Vdc or 4..20 mA
• PST..R -series: relay output with gold plated SPDT contact
2
3
Protection class
IP65
Housing material
Polybutylene terephtalate (PBT)
Sensing element material
1.4571 + 1.4435
Media temperature
-20 ... 100 oC
Media temp. limit
Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature
-20 ... 60 oC
5
Switch function/capacity
6
PST-models: Open collector switch max. 250 mA dc at 14 ... 36
Vdc. PST..R-models with relay contact output, 1 x SPDT, material
silver gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5
mA. With bigger loads, the gold layer will disappear, the capacity
with the silver contacts is: 230 Vac 3(1) A.
Additional description
4
7
8
• Applicable parameter settings:
• switching Set / Reset points
• filters
• analog output range
• electrical drag indicator
• Applicable configurations:
• Max-Min, Window monitor
• Analog output signal
• Pressure unit
• Simulation mode
Switch + Transmitter, PST ...-models
Pressure range
bar
-1 ... 1
0 ... 0,25
0 ... 0,4
0 ... 0,6
0 ... 1
0 ... 1,6
0 ... 4
0 ... 10
0 ... 25
0 ... 2
0 ... 10
9
10
11
12
13
14
6-30
http://europe.hbc.honeywell.com
Max. pressure
bar
6
1
2
2
6
6
12
30
75
6
30
Kind of pressure
vacuum, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
absolute
absolute
Type
PSTV01RG34F
PSTM250RG34F
PSTM400RG34F
PSTM600RG34F
PST001RG34F
PST02RG34F
PST004RG34F
PST010RG34F
PST025RG34F
PST002AG34F
PST010AG34F
Pressure sensors
1
Switch + Transmitter + Relay output, PST..R -models
Pressure range
bar
-1 ... 1
0 ... 0,25
0 ... 0,4
0 ... 0,6
0 ... 1
0 ... 1,6
0 ... 4
0 ... 10
0 ... 25
0 ... 2
0 ... 10
Max. pressure
bar
6
1
2
2
6
6
12
30
75
6
30
Kind of pressure
vacuum, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
overpressure, relative
absolute
absolute
Type
PSTV01RG34F-R
PSTM250RG34F-R
PSTM400RG34F-R
PSTM600RG34F-R
PST001RG34F-R
PST002RG34F-R
PST004RG34F-R
PST010RG34F-R
PST025RG34F-R
PST002AG34F-R
PST010AG34F-R
2
Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4) / Syphons
5
5-prong M12 plug connector, straight version
ST12-5-G
5-prong M12 plug connector, angled version
ST12-5-A
4-prong M12 plug connector, straight version
ST12-4-G
4-prong M12 plug connector, angled version
ST12-4-A
4-prong M12 plug connector, straight version with 2 m cable
ST12-4-GK
4-prong M12 plug connector, angled version with 2 m cable
ST12-4-AK
Plug protection cap, IP65
STA12
Syphons for high temperature, steel, U-shape. For more accessories, see Accessories for Pressure Switches / Transmitters)
UB430B
3
4
6
7
8
9
10
11
12
13
14
6-31
Pressure sensors
1
Electronic Pressure switch for gases and low viscosity liquids, SmartPress
2
Electronic Pressure switch, with LED display for the field of plant construction, fluidics, process
technology, and pneumatics, as well as in the monitoring and control of pumps and compressors.
Models available with the following output types:
• all models: switch output open collector; 14..36 Vdc, 250 mA
• PST -series: transmitter output; 0..10 Vdc or 4..20 mA
• PST..R -series: relay output with gold plated SPDT contact
Protection class
3
4
Housing material
Polybutylene terephtalate (PBT)
Media temperature
-20 ... 100 oC
Media temp. limit
Higher temperatures are possible, provided that the limit is safeguarded by suitable measures (e.g. water tube trap)
Ambient temperature
-20 ... 60 oC
Switch function/capacity
PST..R-models with relay contact output, 1 x SPDT, material silver
gold plated. Capacity resistive: 24 Vdc, 60 mA / 230 Vac, 6,5 mA.
With bigger loads, the gold layer will disappear, the capacity with
the silver contacts is: 230 Vac 3(1) A.
Sensing element material
1.4571 + 1.4542
Additional description
Applicable parameter settings:
• switching Set / Reset points
• filters
• analog output range
• electrical drag indicator
• Applicable configurations:
• Max-Min, Window monitor
• Analog output-signal
• Pressure unit
• Simulation mode
5
6
7
8
IP65
Switch + Transmitter output, PST-models
9
10
11
12
13
Pressure range
bar
-1 ... 1
Max. pressure
bar
6
0 ... 0,25
1
0 ... 0,4
2
0 ... 0,6
2
0 ... 1,6
6
0 ... 4
12
0 ... 10
30
0 ... 25
75
0 ... 60
180
0 ... 100
300
0 ... 250
500
14
6-32
http://europe.hbc.honeywell.com
Output signal
Kind of pressure
Type
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
vacuum, relative
PSTV01RG12S
overpressure, relative
PSTM250RG12S
overpressure, relative
PSTM400RG12S
overpressure, relative
PSTM600RG12S
overpressure, relative
PST002RG12S
overpressure, relative
PST004RG12S
overpressure, relative
PST010RG12S
overpressure, relative
PST025RG12S
overpressure, relative
PST060RG12S
overpressure, relative
PST100RG12S
overpressure, relative
PST250RG12S
Pressure sensors
Pressure range
bar
0 ... 600
Max. pressure
bar
1000
0 ... 2
6
0 ... 10
30
1
Output signal
Kind of pressure
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
overpressure, relative
PST600RG12S
absolute
PST002AG12S
absolute
PST010AG12S
Type
3
Switch + Transmitter + Relay output, PST..R -models
Pressure range
bar
-1 ... 1
Max. pressure
bar
6
0 ... 0,25
1
0 ... 0,4
2
0 ... 0,6
2
0 ... 1,6
6
0 ... 4
12
0 ... 10
30
0 ... 25
75
0 ... 60
180
0 ... 100
300
0 ... 250
500
0 ... 600
1000
0 ... 2
6
0 ... 10
30
2
Output signal
Kind of pressure
Type
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
0..10Vdc / 4..20 mA +
switch + relay
vacuum, relative
PSTV01RG12S-R
overpressure, relative
PSTM250RG12S-R
overpressure, relative
PSTM400RG12S-R
overpressure, relative
PSTM600RG12S-R
overpressure, relative
PST002RG12S-R
overpressure, relative
PST004RG12S-R
overpressure, relative
PST010RG12S-R
overpressure, relative
PST025RG12S-R
overpressure, relative
PST060RG12S-R
overpressure, relative
PST100RG12S-R
overpressure, relative
PST250RG12S-R
overpressure, relative
PST600RG12S-R
absolute
PST002AG12S-R
absolute
PST010AG12S-R
Accessories / Connectors for plug 1 + 2 (OC and analog outputs) / Plug 3 (relay outputs ST4) / Syphons
5-prong M12 plug connector, straight version
ST12-5-G
5-prong M12 plug connector, angled version
ST12-5-A
4-prong M12 plug connector, straight version
ST12-4-G
4-prong M12 plug connector, angled version
ST12-4-A
4-prong M12 plug connector, straight version with 2 m cable
ST12-4-A-GK
4-prong M12 plug connector, angled version with 2 m cable
ST12-4-A-AK
Plug protection cap, IP65
STA12
Syphons for high temperature, steel, U-shape. for more accessories, see Accessories for Pressure Switches / Transmitters
UB430B
4
5
6
7
8
9
10
11
12
13
14
6-33
Pressure sensors
1
Differential pressure transmitter for air
Differential pressure transmitter for air-conditioning/ventilation.
For filter monitoring, flow control, max. pressure control of gaseous media.
2
3
4
5
6
Kind of pressure
differential pressure, relative
Pressure connection
plastic fitting for hose 5 mm internal
Electrical connection
Plug DIN 43650
Protection class
IP65
Housing material
Macrolon
Sensing method
piezoresistive
Media temperature
-10 ... 70 oC
Medium
gaseous
Ambient temperature
0 ... 50 oC
Power supply
18..30Vac, 16..32Vdc
Max. pressure
20 kPa
Output signal
0..10Vdc
Additional description
Accessories delivered with the sensor are: joining pipe with extensions, 2 m silicon hose, mounting brackets and screws. The SKtypes have jumpersettings for 4 selectable pressure measurement
ranges.
7
8
9
10
11
12
13
14
6-34
http://europe.hbc.honeywell.com
Pressure sensors
1
Without LED-display
Pressure range
Pa
0 ... 500
0 ... 1000
0 ... 2000
-500 ... 500
-1000 ... 1000
Type
Pressure range
Pa
0 ... 500
0 ... 1000
0 ... 2000
-500 ... 500
-1000 ... 1000
Type
SK5
SK10
SK20
SKV5
SKV10
2
3
With LED-display
Plug in bracket for DIN-rail mounting, for more accessories see Accessories for Pressure Switches / Transmitters)
4
SK5-AK
SK10-AK
SK20-AK
SKV5-AK
SKV10-AK
5
H12
6
7
8
9
10
11
12
13
14
6-35
Pressure sensors
1
Double range differential pressure transmitter for air
Double range differential pressure transmitter for air-conditioning/ventilation.
For filter-, fluid-, level monitoring, fan-, blower-, valve-, flap-, air flow control, and environmental
protection.
2
3
4
5
Kind of pressure
differential pressure, relative
Pressure connection
6mm hose pipe
Electrical connection
M20x1,5
Protection class
IP54
Housing material
ABS and POM
Sensing method
piezoresistive
Sensing element material
ABS + POM
Media temperature
-10 ... 70 oC
Medium
gaseous
Ambient temperature
-10 ... 70 oC
Max. pressure
20 kPa
Additional description
Duct Kit DPSK included in delivery of single package.
• Adjustable by jumper to the next higher pressure range.
• Factory settings: see column "pressure range". Full scale pressure range see data sheet
6
With voltage output
Pressure range
Pa
-50 ... 50
-100 ... 100
0 ... 100/250
0 ... 250/500
0 ... 500/1000
0 ... 1000/2500
7
8
Model
Output signal
Power supply
without LCD
without LCD
without LCD
without LCD
without LCD
without LCD
0..10Vdc
0..10Vdc
0..10Vdc
0..10Vdc
0..10Vdc
0..10Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
Model
Output signal
Power supply
with LCD
with LCD
with LCD
with LCD
0..10Vdc
0..10Vdc
0..10Vdc
0..10Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
Type
DPT50
DPT110
DPT100
DPT250
DPT500
DPT1000
With voltage output and display for pressure value
9
Pressure range
Pa
0 ... 100/250
0 ... 250/500
0 ... 500/1000
0 ... 1000/2500
10
11
12
13
14
6-36
http://europe.hbc.honeywell.com
Type
DPT100D
DPT250D
DPT500D
DPT1000D
Pressure sensors
1
With current output (3-wire)
Pressure range
Pa
-50 ... 50
-100 ... 100
0 ... 100/250
0 ... 250/500
0 ... 500/1000
0 ... 1000/2500
Model
Output signal
Power supply
without LCD
without LCD
without LCD
without LCD
without LCD
without LCD
4..20mA
4..20mA
4..20mA
4..20mA
4..20mA
4..20mA
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
Type
DPT53
DPT113
DPT103
DPT253
DPT503
DPT1003
2
3
With current output (3-wire) and display. Max. load of 500 Ohm required 24VAC/DC power supply
Pressure range
Pa
0 ... 100/250
0 ... 250/500
0 ... 500/1000
0 ... 1000/2500
Model
Output signal
Power supply
with LCD
with LCD
with LCD
with LCD
4..20mA
4..20mA
4..20mA
4..20mA
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
18..30Vac, 16..32Vdc
Model
Output signal
Power supply
without LCD
without LCD
without LCD
without LCD
without LCD
without LCD
4..20mA
4..20mA
4..20mA
4..20mA
4..20mA
4..20mA
18..32Vdc
18..32Vdc
18..32Vdc
18..32Vdc
18..32Vdc
18..32Vdc
Type
4
DPT103D
DPT253D
DPT503D
DPT1003D
5
With current output (2-wire)
Pressure range
Pa
-50 ... 50
-100 ... 100
0 ... 100/250
0 ... 250/500
0 ... 500/1000
0 ... 1000/2500
6
Type
DPT52
DPT112
DPT102
DPT252
DPT502
DPT1002
7
8
Accessories
Duct Kit, including 2m silicone-hose and 2 joining pipes DPSJ with screws
DPSK
Mounting brackets L-shaped
DPSL
9
10
11
12
13
14
6-37
Air quality sensors
Air quality sensors
1
Air quality sensor
For detection of unpleasant odours, tobacco smoke, and vapours emitted by such materials as
furniture, carpets, paint, glue, etc.
2
3
Protection class
II as per EN60730-1I IP30 as per EN60529
Output signal
0..10Vdc
Power supply
24 Vacdc; 1 VA
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Additional description
Adjustable output offset and LED display
4
Type
C7110A1005
5
Room CO2 sensor
For sensing or controlling of CO2 concentration in buildings.
6
7
8
LED functions
operation as CO2 indicator
Output signal
the following CO2 output signals are applicable, analog or digital
• 0..10V for 0..2000 ppm (factory setting)
• 0..10 V or 2..10 V for 0..2000 ppm or 0..3000 ppm (configurable)
• digital output with adjustable CO2 setpoint and hysteresis for
ventilation on/off
Power supply
24 Vac; 2 VA
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
Wiring terminals
3
Type
C7110C1001
9
10
11
12
13
14
6-38
http://europe.hbc.honeywell.com
Air quality sensors
1
Room temperature/ CO2 sensor
For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
LED functions
operation as occupancy indicator
Output signal
the following CO2 output signals are applicable, analog or digital
• 0..10V for 0..2000 ppm (factory setting)
• 0..10 V or 2..10 V for 0..2000 ppm or 0..3000 ppm (configurable)
• digital output with adjustable CO2 setpoint and hysteresis for
ventilation on/off
Temperature element
NTC20k
Temperature range
10 ... 35 oC
Setpoint knob
-5 ... 5 oC
Extra setp. knob
12 ... 30 oC
Occupancy switch
auto/bypass
Power supply
24 Vac; 2 VA
Mounting place
internal wall
Housing (HxWxD)
104 mm; 99 mm; 30 mm
2
3
4
5
Wiring terminals
7
Additional description
Temperature setpoint potentiometer delivered with 4 setpoint
wheels; white and blue, relative and absolute scale.
6
Type
C7110D1009
7
CO2 air quality and temperature sensor
8
For sensing or controlling of CO2 concentration; and temperature measurement in buildings.
Output signal
Power supply
Additional description
the following output signals are applicable:
• 0..10Vdc/0..20mAdc for 0..2000/3000 ppm CO2
• 0..10Vdc/0..20mAdc for 0..50 oC
• relay output with adjustable CO2 setpoint and hysteresis for
ventilation on/off
9
24 Vac; 2 VA
• Models with LCD available for CO2 concentration or temperature reading.
• Contact input for occupancy detection.
• RS232-port for connection with PC for parameter settings.
• Service interval 5 years, according 89/336EEC.
Mounting place
internal wall
internal wall
air duct
air duct
Model
without LCD
with LCD
without LCD
with LCD
10
11
Type
AQS51
AQS61
AQS51-KAM
AQS61-KAM
12
CO2 test set with gas generator for 0 ppm calibration
AQS-F0005
Interface cable to PC
AQS3/4CABLE
Service software for parameter settings
AQSPC
13
14
6-39
Miscellaneous
Miscellaneous
1
Solar sensor
Sensor to register solar radiation. Including two sensing elements.
Protection class
2
3
IP34
Mounting place
wall outside
Housing (HxWxD)
120 mm; 60 mm; 50 mm
Wiring terminals
3
Additional description
To be connected to a 10Vdc output from a controller as power
supply. The solar output signal (0..5Vdc = 0..500 W/m2) must be
connected to an analogue input of the controller.
Type
SAF25
4
Room temperature sensor, Pt100
5
Approvals
6
7
IEC751 class B
Protection class
IP30
Temperature element
Pt100
Temperature range
0 ... 50 oC
Mounting place
internal wall
Housing (HxWxD)
130 mm; 80 mm; 34 mm
Wiring terminals
2
Type
T7412A1059
8
Air duct temperature sensor, PT100
9
10
11
Approvals
IEC751 class B
Protection class
housing IP54, pipe IP20
Temperature element
Pt100
Temperature range
-40 ... 80 oC
Mounting place
air duct
Immersion depth
135 mm
Wiring terminals
2
Type
T7411A1043
12
13
14
6-40
http://europe.hbc.honeywell.com
Miscellaneous
1
Air duct temperature sensor PTC, active
Protection class
IP65
Output signal
0..10 Vac
Power supply
24 Vacdc; 1 VA
2
Temperature element
Pt100
Temperature range
0 ... 30 oC
Additional description
Aluminium coil for avarage measurement 3,8 m. Sensor supplied
with coil clamp.
3
Type
LF24
4
Electronical air flow switch for air
5
Air flow monitor consisting of two parts: the sensor type SLF.. and the belonging evaluation unit
type ASL...
For air flow monitoring in air-conditioning systems, ventilation and cooling systems and wherever
flow processes in air or neutral gases have to be detected.
Protection class
sensor: IP32
Output signal
evaluation unit: relay SPST 8A, 250Vac, switch point adjustable
from 0,1..20 m/s air speed
Additional description
Media temperature at sensor: -20..120 oC.
6
7
Sensor
Mounting place
air duct
Immersion depth
mm
35
Power supply
Vac; VA
–; –
Type
Immersion depth
mm
–
–
Power supply
Vac; VA
24; 3
230; 3
Type
8
SLF3
Evaluation Unit
Mounting place
universal
universal
9
ASL453/24
ASL453
10
11
12
13
14
6-41
Miscellaneous
1
Electronical flow switch for liquid
Fluid flow monitor consisting of two parts: the sensor type SWF.. and the belonging evaluation unit
type ASW...
2
Protection class
sensor: IP65; evaluation unit: IP32
Output signal
evaluation unit: relay SPST 8A, 250Vac, switch point adjustable,
lowest 0,03 m/s fluid speed
Additional description
For sensor:
• media temperature 0..80 oC
• sensing element steel
3
Sensor
4
5
Power supply
Vac; VA
–; –
–; –
Mounting place
Power supply
Vac; VA
230; 3
24; 3
Mounting place
in pipe
in pipe
Immersion depth
mm
25
45
Type
Immersion depth
mm
–
–
Type
SWF62
SWF62L
Evaluation unit
6
universal
universal
ASW454
ASW454/24
7
8
Paddle flow switches for air
The flow switches are designed for monitoring flow rates in pipes and ducts employed in HVAC
applications.
For monitoring flow of non-aggressive gases in air ducts of air conditioning systems and air treatment systems.
9
10
11
Protection class
IP65
Switch function/capacity
SPDT, capacity 250Vac, (8)15 A
Setpoint device
screw
Max. media temperature
85 oC
Setpoint range
2,5..9,2m/s
Max. pressure
0,25 bar
Type
S6040A1003
12
13
14
6-42
http://europe.hbc.honeywell.com
Miscellaneous
1
Paddle flow switches for liquid
The flow switches are designed for monitoring flow rates in pipes and ducts employed in HVAC
applications.
For monitoring flow in water, oil, cooling circuits, and lubrication systems.
Protection class
IP65
Switch function/capacity
SPDT, capacity 250Vac, (8)15 A
Setpoint device
screw
Approvals
TUEV-approval
Max. media temperature
120 oC
Setpoint range
0,6..165 m3/h pipe size dependent
2
3
4
Liquid
Media
liquid non-aggressive
liquid aggressive
Max. pressure
bar
11
30
Type
S6065A1003
S6065A2001
5
Electronic flow switches for liquid, compact version
6
The high reliable compact electronic flow switch is designed for detecting water flow in pipes. As
soon as medium flow speed exceeds or falls under a customer adjusted value, the device will
switch a electric circuit.
Protection class
IP65
Switch function/capacity
SPDT, capacity 250 Vac, 10(2) A
Immersion depth
20 mm
Media
liquid and air
Setpoint range
0,05..3 m/s
7
8
o
Max. media temperature
80 C
Max. pressure
30 bar
Additional description
LED's available for indication of power supply and switch status.
9
Process connection G1/2"
Power supply
Vac; VA
24; 4
230; 4
Type
10
KSW24
KSW230
11
12
13
14
6-43
Miscellaneous
1
Dew-point sensor
This early-warning dew-point sensor is designed for use in monitoring
cooling water pipes or chilled surfaces in order to determine if temperatures are approaching the dewpoint. It is suitable for mounting on flat and
round surfaces. The sensor measures the relative humidity prevailing directly at the chilled surface and can thus be used to:
• regulating cooling performance
• switching cooling systems ON and OFF
• signalling if the temperature is approaching the dew-point
Switching point at 90 %R.H.
2
3
4
5
Switch function/capacity
potential free semi-conductor contact, load max. 15 mA
R.H. hysteresis switching
point
5 %rh
Ambient temperature
-10 ... 70 oC
Cable length
2m
Housing (HxWxD)
15,5 mm; 32 mm; 50 mm
Type
H7018A1003
6
7
8
9
10
11
12
13
14
6-44
http://europe.hbc.honeywell.com
LON field devices
Actuators
Temperature sensors
Pressure sensors
Page
7-2
7-4
7-6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Actuators
Actuators
1
Actuator + PI-controller LON for radiator valves/zone control, 2,5/6,5 mm 90/180/300
N, M7410G
Electrical actuator with LON input signal for the following valve types:
• 2,5 mm stroke: V100 (thermostatic valves), V58..A4, V58..C4 series
• 6,5 mm stroke: V5822, V5823, V5832, V5833, V5825 series
2
3
4
Protection class
IP42
Position indication
with red indicator
LonMark(R) profile
input SNVT percent 0-100%; for actuators with PI-control object:
open loop actuator object type 3, controller object type 20000
Transceiver type
FTT 10A
Power supply
24 Vac; 1,4 VA
Control input signal
LON
Cable length
1,5 m
Additional description
Contact input available for override function fully open or closed.
Manual operation with valve cap. Configurable parameters for direct/reverse acting. LED-indication for servicing.
5
2,5 mm; 90 N
Stem force
N
90
90
6
7
Stroke
mm
2,5
2,5
Runtime
s
53
53
PI control object
Stroke
mm
6,5
6,5
Runtime
s
150
150
PI control object
Stroke
mm
6,5
6,5
Runtime
s
150
150
PI control object
–
•
Type
M7410G1008
M7410G1032
6,5 mm; 180 N
Stem force
N
180
180
8
–
•
Type
M7410G1016
M7410G1040
6,5 mm; 300 N
Stem force
N
300
300
9
10
11
12
13
14
7-2
http://europe.hbc.honeywell.com
–
•
Type
M7410G1024
M7410G1057
Actuators
1
Actuator LON, 20 mm 600 N, ML7420G
Electrical actuator with LON capabilities, for valve series: V5011, V5013, V5016A, V5025, V5049,
V5050, V5328, V5329.
Protection class
IP54
Position indication
scale plate
Stem position at control
signal loss
selectable: closed, half open, open
Stem force
600 N
Power supply
24 Vac; 7 VA
2
3
Control input signal
LON
Stroke
20 mm
Manual operation
yes
Runtime
1,0 min
Additional description
The control action is reversable. Actuator parameter set can be
defined by using the available Plug In.
4
5
20 mm; 600 N
Model
–
2 digital Inputs
2 digital Outputs
Type
ML7420G1004
ML7420G1012
ML7420G1020
6
7
Accessories
Dual end switches SPDT, adjustable (250 V~, 10 A)
43191680-005
High temperature kits for:
V5011R/S, V5013R/E; V5328A/V5329A DN15..32
43196000-001
V5016A/V5025A/V5050A DN15..80; V5049A DN15..65; V5095A DN20..80; V5328A/
V5329A DN40..80
43196000-002
8
9
10
11
12
13
14
7-3
Temperature sensors
Temperature sensors
1
Room temperature sensor NTC, LON
Room sensor for mounting on wall, with LON connection.
For temperature measurement in domestic and industrial areas.
2
3
4
Wiring connection
M12 plug connector
Protection class
IP65
Output signal
Echelon bus LONTalk protocol
LonMark(R) profile
temperature profile 1040
Transceiver type
FTT 10A
Power supply
24 Vacdc; 1 VA
Temperature element
NTC20k
Temperature range
0 ... 50 oC
Mounting place
internal wall
Sensing element (dia x L)
3 mm; 65 mm
Additional description
LON service and operation LED visible without disassembly.
Mounting bracket H11 included.
5
Type
AFF-L
6
Water temperature sensor NTC, LON
7
Water immersion temperature sensor including well, with LON connection.
8
9
10
Wiring connection
M12 plug connector
Protection class
IP54 (with vertical sensor position)
Output signal
Echelon bus LONTalk protocol
LonMark(R) profile
temperature profile 1040
Transceiver type
FTT 10A
Power supply
24 Vac; 1 VA
Temperature element
NTC20k
Temperature range
-20 ... 110 oC
Mounting place
in pipe
Immersion well material
brass
Immersion well thread
R1/2"
Immersion depth
mm
135
300
11
12
13
14
7-4
http://europe.hbc.honeywell.com
Type
VF20T-L
VF20L-L
Temperature sensors
1
Water temperature sensors NTC, fast reaction time,LON
Sensor for direct mounting in pipe, G1/2", with LON connection.
For water temperature measurement in district heating or hot water supply.
Wiring connection
M12 plug connector
Protection class
IP65
Output signal
Echelon bus LONTalk protocol
LonMark(R) profile
temperature profile 1040
Transceiver type
FTT 10A
Power supply
24 Vac; 1 VA
2
3
Temperature element
NTC20k fast
Temperature range
-20 ... 110 oC
Mounting place
in pipe
Cable length
2,5 m
Additional description
Reaction time max. 2 sec. Sensing material steel 1.4571. Immersion depth adjustable. LON service and operation LED visible
without disassembly.
Immersion depth
mm
max. 75
max. 300
4
Sensing element (dia x L)
mm; mm
4; 75
4; 300
5
Type
6
T7425A1005-L
T7425A1013-L
7
Air duct temperature sensor NTC, LON
Wiring connection
M12 plug connector
Protection class
IP54 (with vertical sensor position)
Output signal
Echelon bus LONTalk protocol
LonMark(R) profile
temperature profile 1040
Transceiver type
FTT 10A
Power supply
24 Vacdc; 1 VA
Temperature element
NTC20k
Temperature range
-30 ... 110 oC
Mounting place
air duct
Immersion depth
280 mm
Cable length
2,5 m
8
9
10
11
Type
LF20-L
12
13
14
7-5
Pressure sensors
Pressure sensors
1
Differential pressure transmitter for liquids and gases, LON
Differential pressure sensor with LON connection.
For differential pressure control of liquids or gaseous media, e.g. for district heating or cooling.
2
3
4
5
6
Kind of pressure
differential pressure, relative
Pressure connection
G1/4 male
Electrical connection
terminal connection 2 x M16x1,5
Protection class
IP65
Housing material
Macrolon
Sensing method
mechanical-inductive
Sensing element material
1.4571 + 1.4435
Media temperature
0 ... 70 oC
Medium
liquid/gaseous
Ambient temperature
0 ... 50 oC
Power supply
19..29Vac, 24..36Vdc
Output signal
LON
LonMark(R) profile
pressure profile 1030
Transceiver type
FTT 10A
Additional description
LON service and operation LED visible without disassembly.
Pressure range
bar
0 ... 1
0 ... 2,5
0 ... 5
0 ... 10
7
8
Max. pressure
bar
10
15
15
15
Type
FHBN1-355-L
FHBN3-355-L
FHBN5-355-L
FHBN10-355-L
Accessories
9
Mail adapter union, brass G1/4 external thread with 8 mm
MAU8/Ms
Mail adapter union, steinless steel G1/4 external thread with 8 mm
MAU8/Nst
Shut-off valve combination, 3 venting valve
VKD3
Shut-off valve combination, 5 venting valve
VKD5
10
11
12
13
14
7-6
http://europe.hbc.honeywell.com
Pressure sensors
1
Differential/over- pressure transmitter for non-aggressive gases, LON
Differential/over- pressure transmitter with LON connection.
For pressure control of gaseous media, for air conditioning or ventilation.
Kind of pressure
differential pressure, relative
Pressure connection
4,8 mm diameter
Protection class
IP65
Housing material
Macrolon
Sensing method
piezoresistive
Media temperature
-10 ... 70 oC
2
3
Medium
gaseous
Ambient temperature
-10 ... 70 oC
Power supply
19..29Vac, 24..36Vdc
Output signal
LON
LonMark(R) profile
pressure profile 1030
Transceiver type
FTT 10A
Additional description
LON service and operation LED visible without disassembly.
Mounting bracket H11 included.
4
5
6
Over pressure sensor
Pressure range
Pa
0 ... 250
0 ... 1250
Max. pressure
kPa
10
15
Type
Pressure range
Pa
-250 ... 250
-1250 ... 1250
Max. pressure
kPa
15
15
Type
SKN250-L
SKN1250-L
7
Differential pressure sensor
8
SKVN250-L
SKVN1250-L
9
Accessories
Plug M12 five-pole
ST355
5-pole T-divider
TST355
XIF-file Low Pressure
XIFLP1
XIF-file High Pressure
XIFHP1
10
11
12
13
14
7-7
Pressure sensors
1
Pressure transmitter for liquids and gases, LON
Pressure transmitter with LON connection.
For pressure control of liquids or gaseous media, e.g. for district heating or cooling.
2
3
4
5
6
Kind of pressure
overpressure, relative
Pressure connection
G1/2 external
Protection class
IP65
Housing material
Macrolon
Sensing method
piezoresistive
Sensing element material
1.4571 + 1.4435
Media temperature
-30 ... 100 oC
Medium
liquid/gaseous
Ambient temperature
0 ... 50 oC
Power supply
19..29Vac, 24..36Vdc
Output signal
LON
LonMark(R) profile
pressure profile 1030
Transceiver type
FTT 10A
Additional description
LON service and operation LED visible without disassembly.
Pressure range
bar
0 ... 0,25
0 ... 1
0 ... 2,5
0 ... 6
0 ... 10
0 ... 25
7
8
9
10
11
12
13
14
7-8
http://europe.hbc.honeywell.com
Max. pressure
bar
0,75
3
7,5
18
30
70
Type
SN025-355-L
SN1-355-L
SN3-355-L
SN6-355-L
SN10-355-L
SN25-355-L
Thermostats
Frost protection
Safety thermostats
Room thermostats
Page
8-2
8-4
8-9
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Frost protection
Frost protection
1
Frost protection thermostat with capillary
Line voltage frost protection thermostat for reheaters in air conditioning systems, and heat exchangers in cooling systems.
2
3
4
Housing material
ABS and corrosion protected steel (IP65 Makrolon)
Ambient temperature
-15 ... 55 oC
Switch function/capacity
SPDT 24..250 Vac, 15(8)A
Thermostat application
frost protection thermostat
Temp. setpoint range
-10 ... 12 oC
Differential fixed
1K
Temperature element
capillary
Additional description
For thermostats with capillary lengths 3m and 6m the DBZ-05
package is included.
Capillary tube length
m
1,8
3
6
1,8
3
6
1,8
3
6
1,8
3
6
5
6
7
8
Mechanical lock/reset
Protection class
manual
manual
manual
auto
auto
auto
manual
manual
manual
auto
auto
auto
IP40
IP40
IP40
IP40
IP40
IP40
IP65
IP65
IP65
IP65
IP65
IP65
Type
T6950A1000
T6950A1018
T6950A1026
T6951A1009
T6951A1017
T6951A1025
T6960A1008
T6960A1016
T6960A1024
T6961A1007
T6961A1015
T6961A1023
Accessories
Fastening clamps 5 pieces
9
10
11
12
13
14
8-2
http://europe.hbc.honeywell.com
DBZ-05
Frost protection
Frost protection thermostat for duct mounting, 2 phases
1
Two phases frost protection thermostat with limiter contact and integrated priority selection
• phase 1, opening heating valve
• phase 2, switch off the unit
Line voltage frost protection thermostat for heater batteries in air handling units.
2
Electrical connection
Plug DIN 43650
Protection class
IP65
Housing material
die cast metal GD Al Si 12 to DIN 1725
Ambient temperature
12 ... 50 oC
Switch function/capacity
SPDT 250 Vac Microswitch / 8A
Power supply
19..29Vac, 24..36Vdc
Output signal
0..10Vdc
Thermostat application
frost protection thermostat, 2-phases
Temp. setpoint range
3 ... 10 oC
3
4
5
Capillary tube length
m
3
6
Type
6
FTSB015
FTS015
Accessories
Capillary tube holder
H3
Capillary tube bushing
R4
Capillary tube bushing
R5
7
8
9
10
11
12
13
14
8-3
Safety thermostats
Safety thermostats
1
Safety limiting thermostat, with hand reset
Sealing pipe thermostat with well.
Protection class
2
3
4
5
IP54
Housing material
Aluminium diecasting with plastic cover
Ambient temperature
0 ... 80 oC
Switch function/capacity
SPST 230 Vac, 10 A
Mechanical lock/reset
mechanical lock, with hand reset on outside of thermostat
Immersion depth
150 mm
Certificates
TUEV-approval STB 89 501
Thermostat application
immersion tube thermostat
Thermostat functions
temp. setting inside, reset outside
Temp. setpoint range
60 ... 130 oC
Mounting place
in pipe
Immersion well material
red brass, nickel plated
Immersion well thread
R1/2"
Max. perm. temp. at sensor
150 oC
6
Type
STB1
7
Accessories
8
Safety limiting thermostat, hand reset, large temperature range
T4NST
Steel well R1/2" x 150 mm
Sealing pipe thermostat with well.
Protection class
9
10
11
12
IP54
Housing material
Aluminium diecasting with plastic cover
Ambient temperature
0 ... 80 oC
Switch function/capacity
SPDT 230 Vac, 10 A
Mechanical lock/reset
mechanical lock, hand reset
Certificates
TUEV-approval STW (STB)89 401 S
Thermostat application
immersion tube thermostat
Thermostat functions
temp. setting inside, reset inside
Temp. setpoint range
20 ... 150 oC
Mounting place
in pipe
Immersion depth
150 mm
Immersion well material
red brass, nickel plated
Immersion well thread
R1/2"
Max. perm. temp. at sensor
175 oC
Additional description
Fixed switching differential approx. 4% of setpoint value.
13
Type
STW1
14
Accessories
Steel well R1/2" x 150 mm
8-4
http://europe.hbc.honeywell.com
T4NST
Safety thermostats
1
Safety limiting thermostat with setpoint knob, and shut-off
Sealing pipe thermostat with well.
For safety temperature control, and in addition high temperature shut-off functionality.
2
Protection class
IP54
Housing material
Aluminium diecasting with plastic cover
Ambient temperature
0 ... 80 oC
Switch function/capacity
safety control switch SPDT 230 Vac, 10 A; shut-off temperature
switch SPST 230 Vac, 10 A
Mechanical lock/reset
shut-off mechanical lock, with hand reset on outside of thermostat
Immersion depth
150 mm
Certificates
TUEV-approval TR / STB 90 001
Thermostat application
immersion tube therm. + controller
3
4
Thermostat functions
temp. setting inside + outside, reset outside
Temp. setpoint range
30 ... 110 oC
Mounting place
in pipe
Immersion well material
red brass, nickel plated
Immersion well thread
R1/2"
Max. perm. temp. at sensor
130 oC
Additional description
Safety control switching differential approx. 4% of setpoint value.
Shut-off temperature: 30..110 oC adjustable.
5
6
7
Type
STB+TR
Accessories
Steel well R1/2" x 150 mm
8
T5NST
9
10
11
12
13
14
8-5
Safety thermostats
1
Safety limiting thermostat with setpoint knob, and shut-off, automatic reset
Sealing pipe thermostat with well.
For safety temperature control, and in addition high temperature shut-off functionality.
2
3
4
5
6
Protection class
IP54
Housing material
Aluminium diecasting with plastic cover
Ambient temperature
0 ... 80 oC
Switch function/capacity
safety control switch SPDT 230 Vac, 10 A; shut-off temperature
switch SPST 230 Vac, 10 A
Mechanical lock/reset
shut-off mechanical lock, automatic reset
Immersion depth
150 mm
Certificates
TUEV-approval TR / STW (STB)89 901 S
Thermostat application
immersion tube therm. + controller
Thermostat functions
temp. setting inside + outside, reset inside
Temp. setpoint range
20 ... 150 oC
Mounting place
in pipe
Immersion well material
red brass, nickel plated
Immersion well thread
R1/2"
Max. perm. temp. at sensor
175 oC
Additional description
Safety control switching differential approx. 4% of setpoint value.
Shut-off temperature: 20..150 oC adjustable.
7
Type
STW+TR
Accessories
8
Steel well R1/2" x 150 mm
9
10
11
12
13
14
8-6
http://europe.hbc.honeywell.com
T5NST
Safety thermostats
1
Safety limiting thermostat, with shut-off
Sealing pipe thermostat with well.
For safety temperature control, and in addition high temperature shut-off functionality.
2
Protection class
IP54
Housing material
Aluminium diecasting with plastic cover
Ambient temperature
0 ... 80 oC
Switch function/capacity
safety control switch SPDT 230 Vac, 10 A; shut-off temperature
switch SPST 230 Vac, 10 A
Mechanical lock/reset
shut-off mechanical lock, with hand reset on outside of thermostat
Immersion depth
150 mm
Certificates
TUEV-approval TW / STB 90 401
Thermostat application
immersion tube therm. + monitor
3
4
Thermostat functions
temp. setting inside + outside, reset outside
Temp. setpoint range
30 ... 110 oC
Mounting place
in pipe
Immersion well material
red brass, nickel plated
Immersion well thread
R1/2"
Max. perm. temp. at sensor
130 oC
Additional description
Safety control switching differential approx. 3..4% of setpoint value. Shut-off temperature: 30..110 oC adjustable.
5
6
7
Type
STB+TW
Accessories
Steel well R1/2" x 150 mm
8
T5NST
9
10
11
12
13
14
8-7
Safety thermostats
1
Safety limiting thermostat, automatic reset
Sealing pipe thermostat with well.
The temperature monitor can be used for heating systems according to DIN 4751 for steam and
hot water systems and for district heating systems.
2
Protection class
3
4
5
6
IP54
Housing material
Aluminium diecasting with plastic cover
Ambient temperature
0 ... 80 oC
Switch function/capacity
SPDT 230 Vac, 10 A
Mechanical lock/reset
no mechanical lock
Immersion depth
100 mm
Certificates
TUEV-approval TW 89 201
Thermostat application
immersion tube thermostat
Thermostat functions
temp. setting inside, automatic reset
Temp. setpoint range
20 ... 150 oC
Mounting place
in pipe
Immersion well material
red brass, nickel plated
Immersion well thread
R1/2"
Max. perm. temp. at sensor
175 oC
Type
TWP1
7
Accessories
T4NST
Steel well R1/2" x 150 mm
8
Flue gas thermostat
Flue gas thermostat for safety control of solid fuel boilers (in combination with oil boilers).
9
Switch function/capacity
10
SPDT 10A/250Vac
Setpoint device
inside
Mounting place
flue gas vent
Temp. setpoint range
20 ... 400 oC
Differential setting range
10 ... 18 oC
Type
RGT240
11
12
13
14
8-8
http://europe.hbc.honeywell.com
Room thermostats
Room thermostats
1
Room thermostat, industrial, 1/2 stages
Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas.
Housing material
glass fibre reinforced ABS
Setpoint device
knob
2
Thermostat application
room thermostat
Additional description
T6120B is dual stage, with 2..10 K difference between the stages.
Temp. setpoint range
C
0 ... 60
Differential setting
range
K
–
0 ... 60
2 ... 10
-30 ... 30
2 ... 10
-30 ... 30
–
-30 ... 30
–
o
Switch function/capacity
SPDT 250Vac 10A
(1,5A)
SPDT 250Vac 10A
(1,5A)
SPDT 250Vac 10A
(1,5A)
SPDT 250Vac 10A
(1,5A)
SPDT 250Vac 15A
(8A)
Differential fixed
Protection class
K
1
IP54
T6120A1005
–
IP54
T6120A1013
–
IP54
T6120A1021
1
IP54
T6120A1039
1
IP65
T6120B1003
3
Type
4
5
6
7
Room thermostat, corrosion resistive
Line voltage thermostat for control of heating-, cooling-, and ventilation systems in farm buildings,
storage areas, swimming pools etc.
Switch function/capacity
SPST enclosed Micro switch 230Vac , 5 A resistive, 3,7 A inductive
8
o
Differential fixed
1,7 C
Temperature element
capillary
Heating /Cooling application
H or C
9
Temp. setpoint range
o
C
-10 ... 30
20 ... 60
Type
10
T631C1178
T631C1160
11
12
13
14
8-9
Room thermostats
1
Room thermostat for industrial permises
2
Room thermostats are suitable for industrial plant, for greenhouses, cowsheds and warehouses,
also for monitoring the maximum temperature in switchgear cabinets and relay stations.
Line voltage thermostat for control of heating-, cooling-, and ventilation systems in industrial areas.
3
4
Electrical connection
Plug DIN 43650
Protection class
IP54
Housing material
die cast metal GD Al Si 12 to DIN 1725
Ambient temperature
-15 ... 70 oC
Switch function/capacity
SPDT 250 Vac, 8(5) A
Optional functions
add the type numbers below to the listed type numbers for extra
functionality as described
• -213: gold plated contacts, switching capacity: max. 24 Vdc,
100 mA, min. 5 Vdc, 2 mA. And others not available with adjustable switching difference.
• -301: terminal connection housing, IP65
• -351: protection class IP65 and switching housing with surface
protection (chemical version)
• -513: gold-plated contacts, IP65, capacity: max. 24 Vdc, 100
mA, min. 5 Vdc, 2 mA
Thermostat application
room thermostat, industrial
Additional description
Including mounting bracket typenumber H1.
5
6
Fixed switching difference
7
Temp. setpoint range
o
C
-20 ... 20
0 ... 40
10 ... 50
8
Differential fixed
K
1
1
1
Differential setting range
K
–
–
–
Max. perm. temp. at sensor
o
C
70
70
70
Type
Differential setting range
K
3 ... 10
3 ... 10
Max. perm. temp. at sensor
o
C
70
70
Type
TRM022
TRM40
TRM150
Adjustable switching difference
Temp. setpoint range
o
C
0 ... 40
10 ... 50
9
10
Differential fixed
K
–
–
TRMV40
TRMV150
Accessories
11
Cover for outdoor application
S1
Sealing
P2
Heat conducting compound
WLP1
12
13
14
8-10
http://europe.hbc.honeywell.com
Pneumatic Products
Controllers
Damper/Valve Actuators
Relays
Pneumatic Electrical
Sensors
Thermostat/Humidistat
Miscellaneous
Page
9-2
9-3
9-5
9-8
9-9
9-10
9-13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Controllers
Controllers
1
Pneumatic Sensor Controller System
This comprises a series of dedicated sensors measuring temperature and humidity and transmitting an industry-standard 0.2 to 1 bar (3-15 psi) signal to controllers. The controllers are available
with proportional and proportional plus integral control outputs with or without reset and remote
control point adjustement (CPA). These outputs are used to control air conditioning and heating
plants. Direct indication of the controlled variable can be provided by a gauge calibrated to match
the output of the sensor installed in the tubing of any convenient point.
The RP920 Pneumatic Controllers provide proportional or proportional+integral control of temperature, humidity/or pressure in heating and air conditioning systems depending upon the controller/
sensor combination. The construction is of modular design using modern plastic technology providing a high degree of accuracy and reliability, whilst the compact size and rail mounting saves
panel space. Compensation and a remote set point facility are available, with either proportional
or proportional plus integral output. Gauges can be fitted to indicate the sensor readings and the
output pressure. The control output can be selected as either direct or reverse acting to suit the
application. The set point scale is 0 to 100% on set point knob. Separate scales for available sensors supplied with controller. Authority is 20 to 300% of main sensor span. Compensation start
point is 0 to 100% of compensation sensor span. Integral reset time is 0.5 to 20 min. Proportional
Band is 2.5 to 45% of main sensor span.
2
3
4
5
6
Max. safe air pressure
2 bar
Ambient temperature
5 ... 55 oC
Air connection
Dual barbs to fit either 6 x 1mm (1/4" OD) or 4 x 0.75mm(5/32" OD)
PE tubing. Gauge connection 1/8" NPT.
Supply air pressure
1,25 bar
Model
Proportional controller with CPA
Proportional controller without CPA
Proportional controller with reset and CPA
P + I controller with CPA
P + I controller with reset and CPA
7
8
9
10
11
12
13
14
9-2
http://europe.hbc.honeywell.com
Type
RP920A1009
RP920A1017
RP920B1007
RP920C1005
RP920D1003
Damper/Valve Actuators
Damper/Valve Actuators
1
Pneumatic damper actuator, MP904
Pneumatic actuator for a damper that controls the volume of air in heating, cooling or ventilation
systems.
Max. operating pressure
140 kPa
Air connection
barb fitting for 6 mm 1/4" polyethylene tubing
2
Max. safe air pressure
210 kPa
Stroke
90 mm
Additional description
Pressure operating range for MP904A,C models field adjustable
for 3 spans.
Pressure range
kPa
Positioner
21, 35, 70
21...91
49...91
21, 35, 70
14..49
49...91
21...91
•
–
–
•
–
–
–
Effective dia- Net force at 0 kPa
phragm area
pressure
cm2
N
146
550
146
270
146
550
65
280
65
70
65
280
65
110
Net force at 140
kPa pressure
N
600
600
600
250
500
250
250
Ambient temperature
oC
-30 ... 70
-30 ... 90
-30 ... 90
-30 ... 70
-30 ... 90
-30 ... 90
-30 ... 90
3
Type
4
MP904A5047
MP904B5037
MP904B5052
MP904C1026
MP904D1032
MP904D1040
MP904D1057
5
6
Pneumatic damper actuator with shaft connection, MP913
7
Pneumatic actuator for a damper that controls the volume of air in induction units, mixing boxes,
and variable volume systems.
Max. operating pressure
140 kPa
8
Operating range
21 ... 91 kPa
Air connection
metal barb type slip-on connector for 6 x 1 mm or 1/4" O.D. polyethylene tube
Max. safe air pressure
200 kPa
Ambient temperature
-30 ... 70 oC
Additional description
9
• Shaft connection thread M10
• Rolling diaphragm
Stroke
Effective diaphragm area
Net force at 0 kPa pressure
mm
90
65
100
70
cm2
25
25
45
45
N
45
45
80
80
Net force at 125 kPa pressure
N
80
80
145
145
10
Type
MP913B1068
MP913B1076
MP913C1066
MP913C1074
11
12
13
14
9-3
Damper/Valve Actuators
1
Pneumatic valve actuator, MP953
Pneumatic actuator for valves in heating and air conditioning systems.
Actuators are suitable for valve series: V5011, V5013, V5015, V5049, V5050, V5095, V5328,
V5329.
2
3
Protection class
IP54
Action
direct or reverse acting
Max. operating pressure
140 kPa
Max. safe air pressure
172 kPa
Additional description
4
Pressure range
kPa
34,5 or 69
34,5 or 69
34,5 or 69
34,5 or 69
13,8...48,3
55,2...82,8
27,6...75,9
13,8...48,3
55,2...82,8
27,6...75,9
13,8...48,3
27,6...75,9
55,2...82,8
27,6...75,9
55,2...82,8
5
6
7
8
Adjustable start
point
kPa
20,7 ... 69
20,7 ... 69
20,7 ... 69
20,7 ... 69
–
–
–
–
–
–
–
–
–
–
–
• Rolling diaphragm
• Seewaterproof version: 43191430-001
Positioner
Stroke
•
•
•
•
–
–
–
–
–
–
–
–
–
–
–
mm
20
20
38
20
20
20
20
20
20
20
38
38
20
20
20
Action actuator
stem
extends
extends
extends
retracts
extends
extends
extends
extends
extends
extends
extends
extends
retracts
retracts
extends
Max. ambient
temperature
oC
70
70
70
70
120
120
120
120
120
120
120
120
120
120
120
Type
MP953A5005
MP953A5039
MP953A5054
MP953B5003
MP953C5001
MP953C5019
MP953C5027
MP953C5068
MP953C5076
MP953C5084
MP953C5142
MP953C5159
MP953D5009
MP953D5025
43191430-001
High Temperature Applications, the following bonnet extentions must be used with MP953 actuators when the flowing medium temperature is 150 to 220 degrees C, to give extra air circulation
and less conduction of heat from the valve body to the actuator.
9
10
Used with V5049A up to 65mm, V5050A up to 80mm, V5011R, S 50mm only, V5013R
50mm only, V5328A 40mm to 80mm, V5329A 40mm to 80mm
43161276-001
Used with V5011R,S 15mm to 40mm, V5013R 15mm to 40mm, V5328A 15mm to
32mm, V5329A 15mm to 32mm
43297431-001
11
12
13
14
9-4
http://europe.hbc.honeywell.com
Relays
Relays
1
Electric-pneumatic relay
Relay to switch with an electric voltage the supply air pressure to one or the other output port
Input signal
230 Vac, 9/7 VA ; supply air pressure on port 1
Output signal
air pressure on port 2 or 3
Pressure connection
for 6 x 1 mm or 1/4" PE hose
Mounting
DIN rail or wall
Max. pressure
800 kPa
Media temperature
-10 ... 40 oC
Additional description
Air capacity 55 Nl/h.
2
3
4
Type
RP416A2008
5
Pneumatic selector relay, RP470
Three-port relay to transmit the higher of two input signals.
Branch Line Pressure
range
0 ... 125 kPa
Max. safe air pressure
205 kPa
6
Air connection
barb for 5/32" or 4 mm O.D. plastic tubing
Mounting
In-line; panel; Wall
Includes
14003030-001 1 1/2 in. Mounting Clip for Mounting relay to wall
or panel, 1/4" (6 mm) and 5/32" (4 mm) plastic tubing, connectors,
compression adapters
7
8
Type
RP470A1003
9
Pneumatic snap action relay, RP471
The four port, snap acting relay converts a proportional air pressure change from a controller to a
positive (two-position) pressure change. It can also divert a supply line to one of two branches.
Branch Line Pressure
range
0 ... 125 kPa
Max. safe air pressure
205 kPa
10
Air connection
barb for 5/32" or 4 mm O.D. plastic tubing
Mounting
panel; wall
Model
Pneumatic, four-port, snap acting relay; setpoint 4..17 psi, diff. 2
psi
Includes
14003030-001 1 1/2 in. Mounting Clip for Mounting relay to wall
or panel, 1/4" (6 mm) and 5/32" (4 mm) plastic tubing, connectors,
compression adapters
11
12
Type
RP471A1002
13
14
9-5
Relays
1
Pneumatic switching relay, RP670
2
Pneumatic switching relays block, divert, or bleed pneumatic air lines when pilot pressure is
changed from one specific value to another. Commonly applied in Day-Night, Summer-Winter,
Start- Stop, On-Off-Auto and other multiple condition systems where control sequence is changed
as conditions change.
Branch Line Pressure
range
3
0 ... 152 kPa
Max. safe air pressure
205 kPa
Air connection
barb for 5/32" or 4 mm O.D. plastic tubing
Includes
14003030-001 1 1/2 in. Mounting Clip for Mounting relay to wall
or panel, 1/4" (6 mm) and 5/32" (4 mm) plastic tubing, connectors,
compression adapters
4
Model
Switching pilot relay SPDT, range 3..7 psi
Switching pilot relay SPDT, range 13..18 psi
5
Type
RP670A1001
RP670A1019
Pneumatic Capacity Relay
6
The RP970A is a direct acting, proportional relay suitable for use in HVAC systems to increase the
capacity of a branchline signal to a pneumatic valve or damper operator. The RP970A provides a
1:1 pressure ratio. It can also transmit the lower of 2 pressures.
7
8
Branch Line Pressure
range
0 ... 124 kPa
Max. safe air pressure
205 kPa
Air connection
barb for 5/32" or 4 mm O.D. plastic tubing
Type
RP970A1008
9
Mounting Clip
10
11
12
13
14
9-6
http://europe.hbc.honeywell.com
14003030-001
Relays
1
Pneumatic Ratio Relay
The RP971A produces a modulating pressure output proportional to pilot pressure changes. This
four-port nonbleed direct-acting relay is used to control valves or dampers in sequence from a single pressure input.
Ratio relay. Startpoint adjustable. For RP971A1007 input span 21 kPa and RP9712A1015 input
span 34 kPa
Branch Line Pressure
range
0 ... 124 kPa
Max. safe air pressure
205 kPa
Air connection
barb for 5/32" or 4 mm O.D. plastic tubing
Model
Operating Range 0 to 124 kPa
2
3
4
Type
RP971A1007
RP971A1015
5
Pneumatic Reversing Relay
The RP972A reverses and increases the capacity of the branch line pressure to the final control
device in all types of HVAC systems. May be set to decrease from 13, 16, or 18 psi (90,110 or 124
kPa).
6
Branch Line Pressure
range
7
0 ... 124 kPa
Max. safe air pressure
207 kPa
Air connection
barb for 5/32" or 4 mm O.D. plastic tubing
Model
Operating Range 0 to 124 kPa
8
Type
RP972A1006
Mounting Clip
9
14003030-001
10
11
12
13
14
9-7
Pneumatic Electrical
Pneumatic Electrical
1
Pneumatic electrical relay
Pressure switch with adjustable switching hysteresis.
For air and non burnable gases.
2
3
4
Pressure connection
internal threads R1/4"
Switch function/capacity
SPDT Microswitch 230Vac, 25 A
Pressure adjustment
range
10 ... 100 kPa
Adjustable switching differential
15 ... 40 kPa
Max. pressure
180 kPa
Media temperature
-30 ... 50 oC
Type
L404F1219
5
Electric-pneumatic signal conversion module
6
7
8
Input signal
electrical input 2..10 Vdc
Output signal
pressure output 20..100 kPa, proportional to input signal
Pressure connection
for 4 or 6 mm PE hose
Wiring connection
with 1 metre cable
Mounting
DIN rail
Max. pressure
200 kPa
Media temperature
5 ... 55 oC
Additional description
Air capacity 720 Nl/h.
Power supply
Vacdc; VA
from controller; 10
24; 1,7
9
10
11
12
13
14
9-8
http://europe.hbc.honeywell.com
Model
for Micronik 100
for Excel 5000
Type
RP7517A1009
RP7517B1008
Sensors
Sensors
1
Pneumatic temperature sensor, LP914
Pneumatic sensor for control of hot water or warm air, in heating and airconditioning systems.
Max. safe air pressure
175 kPa
Max. media temperature
130 oC
Supply air pressure
125 kPa
Pressure output
21 ... 103 kPa
Air connection
push-on barb connector for 6 mm or 1/4" O.D. tube
Action
direct acting
Temperature range
oC
-40 ... 70
-40 ... 70
5 ... 115
-40 ... 70
5 ... 115
-5 ... 50
2
Immersion depth
mm
380
380
380
175
175
380
Mounting
duct or well
through outside wall
well or well
duct or well
well
duct or well
3
Type
4
LP914A1151
LP914A1169
LP914A1177
LP914A1193
LP914A1201
LP914A1235
5
6
Accessories
Stainless steel well, 380 mm 1/2" NPT
43163162-001
Stainless steel well, 175 mm 1/2" NPT
43163162-002
7
Pneumatic temperature sensor, LP915
One-pipe, direct-acting temperature sensor used with RP908 or RP920 Controllers to provide proportional control of pneumatic valve or damper actuators. Averaging, liquid-filled element for duct
mounting.
Max. safe air pressure
172 kPa
Max. media temperature
118 oC
9
Supply air pressure
124 kPa
Pressure output
21 ... 103 kPa
Air connection
push-on barb connector for 4 mm or 5/32" and 6 mm or 1/4" O.D.
tube
Capillary tube length
5,6 m
Temperature range
-18 ... 93 oC
Mounting
duct
Action
direct acting
8
10
11
Type
LP915A1044
12
13
14
9-9
Thermostat/Humidistat
Thermostat/Humidistat
1
Pneumatic room temperature controller, TP937/938
2
Room-mounted pneumatic temperature controller; models with a facility for resetting the setpoint
with a signal from a master pneumatic controller.
For proportional control of pneumatic valve- and damper actuators in heating and airconditioning
systems.
3
4
Branch Line Pressure
range
21 ... 105 kPa
Throttling range
adjustable 1,1...5,5 oC
Max. safe air pressure
175 kPa
Max. media temperature
65 oC
Air connection
110 mm tubing with barb type fitting for polyethylene tubing, diameter 6 mm
Mounting
wall
Temp. setpoint range
15 ... 30 oC
Additional description
5
• filter included in air connection and in external H-restriction
• submaster set-up range 5 oC when reset signal increases from
21...91 kPa
Action
direct acting
reverse acting
direct acting
direct acting
reverse acting
6
7
Submaster set-up
–
–
•
•
•
Type
TP937A1006
TP937B1004
TP938A1005
TP938A1013
TP938B1003
Pneumatic unit-temperature controller, TP939/940
8
Unit-mounted pneumatic temperature controller with a 1,2 meter capillary; models with a facility
for resetting the setpoint with a signal from a master pneumatic controller.
For proportional control of pneumatic valve- and damper actuators in heating and airconditioning
systems.
9
10
11
Branch Line Pressure
range
21 ... 105 kPa
Throttling range
3 oC
Max. safe air pressure
175 kPa
Max. media temperature
65 oC
Air connection
110 mm tubing with barb type fitting for polyethylene tubing, diameter 6 mm
Mounting
unit
Temp. setpoint range
15 ... 27 oC
Additional description
12
• filter included in air connection and in external H-restriction
• submaster set-up range 5 oC when reset signal increases from
21...91 kPa
Action
direct acting
reverse acting
direct acting
13
14
9-10
http://europe.hbc.honeywell.com
Submaster set-up
–
–
•
Type
TP939A1004
TP939B1002
TP940A1001
Thermostat/Humidistat
1
Pneumatic room temperature controller, TP970
For proportional control of pneumatic valves and damper actuators in heating and airconditioning
systems. The TP970 incorporates a relay amplifier giving sensitive control and facilitating averaging control, which requires extra relays when bleed-type thermostats are used. The range comprises factory calibrated bi-metal element proportional instruments with a setpoint indicator. The
cover is ordered separately, and restrictors are not required.
Branch Line Pressure
range
21 ... 105 kPa
Throttling range
adjustable 1...5 oC
Max. safe air pressure
175 kPa
Mounting
wall
Temp. setpoint range
15 ... 30 oC
2
3
4
Action
direct acting
reverse acting
Type
TP970A2020
TP970B2010
Satin chrome cover
14004406-120
5
6
Pneumatic room temperature sensor, TP974
One- or two-pipe direct-acting temperature sensor used with RP908/RP920 controllers to provide
proportional control of pneumatic valve and damper actuators.
Max. safe air pressure
170 kPa
Max. media temperature
66 oC
Supply air pressure
124 kPa
Pressure output
21 ... 103 kPa
Air connection
plug-in
Temperature range
10 ... 38 oC
Mounting
wall
Action
direct acting
7
8
9
Type
TP974A2000
Cover
10
14004406-110
11
12
13
14
9-11
Thermostat/Humidistat
1
Pneumatic room humidity controller, HP970
Two-pipe, single setpoint, pneumatic humidistat used to provide proportional control of pneumatic valves on humidification or dehumidification systems.
2
3
Branch Line Pressure
range
21 ... 105 kPa
Throttling range
adjustable 3..15 %rh
Max. safe air pressure
170 kPa
Mounting
wall
R.H. setpoint range
%rh
15 ... 75
15 ... 75
65 ... 95
4
5
Action
direct acting
reverse acting
reverse acting
Type
HP970A1009
HP970B1007
HP970B1015
14004406-124
Cover
Pneumatic room humidity sensor, HP971
6
One- or two-pipe direct-acting humidity sensor used with RP908/RP920 controllers to provide
proportional control of pneumatic valve and damper actuators in systems requiring humidification
or dehumidification control.
7
8
Max. safe air pressure
172 kPa
Max. media temperature
52 oC
Supply air pressure
124 kPa
Pressure output
21 ... 103 kPa
Air connection
1/4 " tubing
Mounting
wall
Action
direct acting
9
R.H. range
%rh
15 ... 75
15 ... 85
10
Cover
11
12
13
14
9-12
http://europe.hbc.honeywell.com
Type
HP971A1008
HP971A1024
14004406-124
Miscellaneous
Miscellaneous
1
Pressure reducing valve with Filter Regulator Station, PP907
Provides reducing of inlet pressure to a constant operating pressure and
filtering e.g. of condensates, dust, oil and rust particles.
• Air consumption 30 Nl/h (500 sccm) at 500 kPa inlet pressure, max. 60 Nl/h (1000 sccm)
• Upper limit of air capacity 10 Nm3/h
• Outlet pressure gauge indication 0...2 bar (0...30 psi) full range
• Sub-micron filter for dust separation and separation of condensates
• Pressure relief valve, fixed at 175 kPa
Supply air pressure
max. 1000 kPa
Pressure output
10 ... 175 kPa
2
3
4
Type
PP907A1008
5
Pneumatic switches, SP470/970
For manual correction of process control-/manual proportional action switching or minimum positioning in pneumatic control systems.
Max. safe air pressure
Air connection
200 kPa
6
• SP470: sharp barb type slip-on connections for 4 mm (5/32")
plastic tubing
• SP970: connectors for 4 mm or 5/32" O.D. plastic tubing
Model
2-position switch
3-position switch
3 port pneumatic switch, span 70 kPa
3 port pneumatic switch, span 35 kPa
Operating range
kPa
0 ... 150
0 ... 150
0 ... 125
0 ... 125
Ambient temperature
o
C
-18 ... 60
-18 ... 60
0 ... 50
0 ... 50
7
Type
SP470A1042
SP470A1059
SP970A1021
SP970A1039
8
9
10
11
12
13
14
9-13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
9-14
http://europe.hbc.honeywell.com
Miscellaneous
Heat meters
Humidistats
Switches
Transformers
Signal modules
Page
10-2
10-6
10-8
10-9
10-11
1
2
3
4
5
6
7
8
9
10
11
12
13
14
Heat meters
Heat meters
1
Water flow combi heatmeter, single-jet EW100
Combi compact electronic heatmeter for water, with display (and output); including temperature
sensors for forward/return.
For measurement of flow of water, the temperature of foward and return water; and calculation of
corresponding energy. Heatmeters are used for billing in private, as well as in industrial and HVAC
environment, as well as in process control.
2
3
4
5
Measuring method
single jet
Approvals
measuring accuracy complies with EN1434 class 2; sensors corresponding to DIN EN 60751
Media temperature
15 ... 90 oC
Temperature difference
range
3 ... 147 K
Display functions
7 digit LCD for: power, energy, flow rate, temperature, date
Batteries
included 3VLi
Protection class
IP54
Static pressure
PN16
Port connection type
external threads
Mounting
horizontal/vertical/down under
Additional description
Models available with electronic output signal, via an optical interface.
6
7
Max. water flow
m3/h
0,6
1,5
2,5
8
With M-bus output
Max. water flow
m3/h
0,6
1,5
2,5
9
DN size
mm
15
15
20
Port diameter
inch
G3/4B
G3/4B
G1B
Output signal
DN size
mm
15
15
20
Port diameter
inch
G3/4B
G3/4B
G1B
Output signal
Port diameter
inch
G3/4B
G3/4B
G1B
Output signal
–
–
–
M-bus
M-bus
M-bus
Type
EW100A6014
EW100A1528
EW100A2526
Type
EW100M6018
EW100M1522
EW100M2520
With 2 pulse outputs, for energy and volume
10
Max. water flow
m3/h
0,6
1,5
2,5
11
DN size
mm
15
15
20
12
13
14
10-2
http://europe.hbc.honeywell.com
2 pulses
2 pulses
2 pulses
Type
EW100P6011
EW100P1525
EW100P2523
Heat meters
1
Water flow combi heatmeter, multi-jet EW110
Combi compact electronic heatmeter for water, with display (and output); including temperature
sensors for forward/return.
For measurement of flow of water, the temperature of foward and return water; and calculation of
corresponding energy. Heatmeters are used for billing in private, as well as in industrial and HVAC
environment, as well as in process control.
Measuring method
multi jet
Approvals
measuring accuracy complies with EN1434 class 2; sensors corresponding to DIN EN 60751
Media temperature
15 ... 90 oC
Temperature difference
range
3 ... 147 K
Display functions
7 digit LCD for: power, energy, flow rate, temperature, date
Batteries
included 3VLi
Protection class
IP54
Static pressure
PN16
Port connection type
external threads
Mounting
horizontal/vertical
Additional description
Models available with electronic output signal, via an optical interface.
Max. water flow
m3/h
3,5
6
10
2
3
4
5
DN size
mm
25
25
40
Port diameter
inch
G1 1/4B
G1 1/4B
G2B
Output signal
DN size
mm
25
25
40
Port diameter
inch
G1 1/4B
G1 1/4B
G2B
Output signal
Port diameter
inch
G1 1/4B
G1 1/4B
G2B
Output signal
–
–
–
6
Type
7
EW110A3522
EW110A6020
EW110A1039
8
With M-bus output
Max. water flow
m3/h
3,5
6
10
M-bus
M-bus
M-bus
Type
EW110M3526
EW110M6024
EW110M1033
With 2 pulse outputs, for energy and volume
Max. water flow
m3/h
3,5
6
10
DN size
mm
25
25
40
2 pulses
2 pulses
2 pulses
9
Type
10
EW110P3529
EW110P6027
EW110P1036
11
12
13
14
10-3
Heat meters
1
Water flow combi heatmeter, Woltmann wheel, EW115
Combi compact electronic heatmeter for water, with display (and output); including temperature
sensors for forward/return.
For measurement of flow of water, the temperature of foward and return water; and calculation of
corresponding energy. Heatmeters are used for billing in private, as well as in industrial and HVAC
environment, as well as in process control.
2
3
4
5
Measuring method
woltmann wheel
Approvals
measuring accuracy complies with EN1434 class 3; sensors corresponding to DIN EN 60751
Media temperature
15 ... 90 oC
Temperature difference
range
3 ... 147 K
Display functions
7 digit LCD for: power, energy, flow rate, temperature, date
Batteries
included 3VLi
Protection class
IP54
Static pressure
PN16
Port connection type
flanges
Mounting
horizontal
Additional description
Models available with electronic output signal, via an optical interface.
6
Max. water flow
m3/h
15
25
40
60
7
8
DN size
mm
50
65
80
100
Output signal
DN size
mm
50
65
80
100
Output signal
DN size
mm
50
65
80
100
Output signal
–
–
–
–
Type
EW115A1539
EW115A2537
EW115A4038
EW115A6033
With M-bus output
Max. water flow
m3/h
15
25
40
60
9
10
M-bus
M-bus
M-bus
M-bus
Type
EW115M1533
EW115M2531
EW115M4032
EW115M6037
With 2 pulse outputs, for energy and volume
Max. water flow
m3/h
15
25
40
60
11
12
13
14
10-4
http://europe.hbc.honeywell.com
2 pulses
2 pulses
2 pulses
2 pulses
Type
EW115P1536
EW115P2534
EW115P4035
EW115P6030
Heat meters
1
Water flow combi heatmeter, ultrasonic EW300
Combi compact electronic heatmeter for water, with display (and output); including temperature
sensors for forward/return.
For measurement of flow of water, the temperature of foward and return
water; and calculation of corresponding energy. Heatmeters are used for
billing in private, as well as in industrial and HVAC environment, as well as
in process control.
• M-bus output, via optical interface
• NOWA test capabilty
Measuring method
ultrasonic
Approvals
measuring accuracy complies with EN1434 class 2; sensors corresponding to DIN EN 60751
Media temperature
15 ... 90 oC
Temperature difference
range
3 ... 130 K
Display functions
7 digit LCD for: power, energy, flow rate, temperature, date
Batteries
included 3VLi
Protection class
IP54
Static pressure
PN16
Port connection type
external threads
Mounting
any direction
Output signal
M-bus
Max. water flow
m3/h
0,6
1,5
2,5
2
3
4
5
6
DN size
mm
15
15
20
Port diameter
inch
G3/4B
G3/4B
G1B
Type
7
EW300M6016
EW300M1520
EW300M2528
8
Electrical power/energy meter, EE7003
9
Power/energy meter with voltage and current inputs; with display and programming key for range
setting. For metering loads from 10 W..3000 kW.
For energy cost allocation tasks in the field of building automation, in office buildings, residential
complexes, shopping centers, camp sites etc.
Input signal
230 Vac 1 phase (max. 16 A), 3 phase (max. 5 A), up to 4000 A with
external current transformers
Approvals
class 2 measuring accuracy IEC1036
Display functions
8 digit LCD for instantaneous power (kW/MW), and cumulative active energy (kWh)
Output signal
1 pulse per kWh
Memory back up
retention of counter data in EEPROM, no battery
Power supply
230 Vac; 3 VA
Ambient temperature
0 ... 50 oC
Protection class
IP20, front panel IP40
Mounting
DIN rail
Housing (HxWxD)
90 mm; 70 mm; 58 mm
10
11
12
13
Type
EE7003A1008
10-5
14
Humidistats
Humidistats
1
Room and air duct humidistats
Line voltage humidistats for (de)humidification 2-point control in air conditioning systems. Also applicable for swimming pools (dehumidifiaction).
2
3
R.H. setpoint range
35 ... 100 %rh
(De) Humidification application
D+H
Additional description
Maximum air flow speed for ducts: 8 m/s.
Room humidistat H6120
R.H. hysteresis
switching point
%rh
4
4
Ambient temperature
oC
0 ... 60
Mounting place
Immersion depth
Switch function/
capacity
mm
– SPDT 230Vac /5A
(0,2A)
internal wall
Protection class
IP30
Type
H6120A1000
Duct humidistat H6045
5
R.H. hysteresis
switching point
%rh
5
6
Ambient temperature
o
C
-10 ... 65
Mounting place
Immersion depth
air duct
mm
222
Switch function/
capacity
Protection class
SPDT 250Vac/
15A (8A)
IP65
Type
H6045A1002
7
8
Room humidistat
Line voltage humidistat for humidity control of rooms.
9
10
11
Switch function/capacity
SPDT 230 Vac, 2 A
R.H. setpoint range
20 ... 80 %rh
R.H. hysteresis switching
point
5 %rh
Ambient temperature
10 ... 50 oC
R.H. sensing element
nylon
(De) Humidification application
D+H
Mounting place
internal wall
Additional description
With removable setpoint knob
Type
H600A1022
12
13
14
10-6
http://europe.hbc.honeywell.com
Humidistats
1
Room humidistat, low voltage
Low voltage humidistat for humidity control of rooms.
Switch function/capacity
SPDT 48 Vac, 6 A
R.H. hysteresis switching
point
5 %rh
Ambient temperature
10 ... 50 oC
R.H. sensing element
nylon
(De) Humidification application
D+H
Mounting place
internal wall
Additional description
With internal setpoint adjustment limiter. Including mounting
base/ring.
2
3
R.H. setpoint range
%rh
30 ... 80
50 ... 90
4
Type
5
H615A2015
H615A2077
6
Air duct humidistat
Line voltage immersion humidistat for air ducts or industrial areas.
Switch function/capacity
SPDT 230 Vac, 15 A
R.H. setpoint range
35 ... 100 %rh
R.H. hysteresis switching
point
4 %rh
Ambient temperature
-30 ... 60 oC
R.H. sensing element
plastic tissue
(De) Humidification application
D+H
Mounting place
air duct
7
8
9
Type
HGK3
10
11
12
13
14
10-7
Switches
Switches
1
Switching module, Q6371
Wall mounted switching module.
For manual control of the valve, or the valve and the fan in fan-coil applications.
2
3
4
Approvals
CE
Protection class
IP30
Switch function/capacity
manual switch outputs, 230Vac, 6 A resistive, 4 A inductive ratings
Manual operation functions
on/off switch
Product literature language
Multilingual
Terminal max. wire size
1,5 mm2
Earthing
double insulated
Housing (HxWxD)
83 mm; 84 mm; 27 mm
Heating /Cooling application
H or C
H+C
H+C
5
6
7
8
9
10
11
12
13
14
10-8
http://europe.hbc.honeywell.com
Fan switch
1/2/3
yes
1/2/3
Heat/Cool manual mode
–
H/C
H/C
Type
Q6371A1006
Q6371C1002
Q6371C1010
Transformers
Transformers
1
Transformer
Protection class
IP00
Input voltage
220/230 V selectable, 50Hz
Output voltage
24Vac
Additional description
With mains fuse. VDE0551 mark.
Model
48 VA
144 VA
288 VA
2
3
Type
CRT2
CRT6
CRT12
4
Transformer, 2 secondary windings
5
Protection class
IP00
Input voltage
230 V, 50Hz
Output voltage
2 x 24Vac, separated
Additional description
With mains fuse. VDE0551 mark.
Model
144/144 VA
150/250 VA
6
Type
CRT6/6
CRT6/12
7
8
9
10
11
12
13
14
10-9
Transformers
1
Transformer wall mounting
Transformer to be mounted outside of cabinets, built in closed housing.
2
Protection class
IP54
Input voltage
220 V, 50/60Hz
Output voltage
24Vac
Model
45 VA
Additional description
3
• With mains cable 1,5 m and mains plug.
• With low voltage cable 3 m, without plug.
Type
ETR2
4
Enclosed Transformer
5
6
Input voltage
240V 50Hz
Output voltage
24V 50Hz
Max. ambient temperature
40 oC
Additional description
• primary fuse 5 x 20 mm glass cartridge slow blow
• conduit entries two 21 mm dia.
• open circuit voltage 25V 50Hz at 240V input
7
Model
40 VA, 315 mA fuse rating
60 VA, 315 mA fuse rating
100 VA, 500 mA fuse rating
250 VA, 1250 mA fuse rating
8
9
10
11
12
13
14
10-10
http://europe.hbc.honeywell.com
Type
TRE40
TRE60
TRE100
TRE250
Signal modules
Signal modules
1
Relay module for on/off and 3-pt control
Two channel signal converter module.
For a signal change from 0..10Vdc (from external controller) into on/off and 3-pt control relay contact output.
Input signal
Output signal
2 x 0..10 Vdc
• relay K1 and K2 SPST contact 240V 0,2 A supplying 3-pt control of first analogue input
• relay K3 SPDT contact 240V 3 A, supplying on/off control of
second analogue input
Mounting
DIN rail
Power supply
24 Vacdc; 5 VA
2
3
4
Type
MCD3
5
Voltage level switch
For conversion of an analogue output signal from a controller into an on/off output signal.
Input signal
0..10 Vdc
Output signal
relay contact SPDT 250 V, 4 A; relay on with input voltage > 3 V,
relay off with input voltage < 2,5 V
Manual operation functions
override switch with auto-off-on position
LED functions
yellow LED showing relay status
Mounting
DIN rail
Power supply
24 Vacdc; 1 VA
6
7
8
Type
MCE1
9
Conversion module 24Vdc/relay
For conversion of an 24 Vdc signal from a digital output of a controller into an on/off output signal.
10
Input signal
0 or 24 Vdc
Output signal
relay contact SPDT 250 V, 4 A; relay on with 24 V, off with 0 V input
signal
Manual operation functions
override switch with auto-off-on position
LED functions
yellow LED showing relay status
Mounting
DIN rail
Power supply
24 Vacdc; 0,5 VA
11
12
Type
MCE2
13
14
10-11
Signal modules
1
Conversion module 0..10Vdc/relay, 3 channel
Three channel signal converter module.
For a signal change from 0..10Vdc (from external controller) into an on/off relay contact output.
2
Input signal
3 x 0..10 Vdc
Output signal
3
• relay K1/K2 SPDT contact 240 V, 2 A
• relay K3 SPST contact 240 V, 2 A
Mounting
DIN rail
Power supply
24 Vacdc; 1 VA
Type
MCE3
4
Status display module, 4 channel
5
Status indication module for external contacts.
6
7
Input signal
4 x external potential free contacts
Output signal
4 x 24Vacdc (from power supply)
LED functions
4 x red or green LED showing the status of the input
Manual operation functions
4 x switch for LED status intervention
Mounting
DIN rail
Power supply
24 Vacdc; 1 VA
Type
MCM1
8
Manual positioning module
9
Manual positioning module for analogue output signals to manually adjust damper and valve actuators or to provide a fixed position.
10
11
Input signal
0..10 Vdc
Output signal
0..10 Vdc from input or from potentiometer (max. 1 mA)
Manual operation functions
potentiometer to adjust output signal 0..10Vdc; switch with auto/
manual position
LED functions
red LED, intensity shows output level
Mounting
DIN rail
Power supply
24 Vacdc; 0,4 VA
Additional description
Potential free contact for feedback of manual override.
Type
MCP1
12
13
14
10-12
http://europe.hbc.honeywell.com
Signal modules
1
Signal separator, 4 channel
Four channel signal separator for galvanic separation of analogue transmitter signals and evaluation devices.
For suppression of interference signals and influences from earth loops.
Input signal
0..10 Vdc (Ri >220 kohm); or 0..20 mA using a 500 ohm resistor at
the input
Output signal
0..10 Vdc (max. 1 mA)
2
3
Mounting
DIN rail
Power supply
24 Vacdc; 1,7 VA
Additional description
The four input channels (and also the power supply) are not galvanically isolated from each other. The four output channels (and
also the power supply) are not galvanically isolated from each other.
Type
GT4
4
5
Relay module for on/off control
6
Signal converter module.
For a signal change from 0..10Vdc (from external controller) into on/off relay contact output.
Input signal
0..10 Vdc (50mA)
Output signal
SPDT contact 3A/240Vac
Mounting
DIN rail
7
Type
CRE1
8
Isolating relay
9
Relay with inbuilt transformer, and waterproof housing.
Switch function/capacity
SPDT contact, maximum load 4A/250Vac
Model
Power supply 230V; 50Hz; control connection 24 V
Protection class
IP40
10
Type
KA10
11
Goldcontact relays
12
Relay with contact material hard silver and gold plating.
For switching of low voltages.
Mounting
including socket for screw connection or DIN rail
Switch function/capacity
3 x SPDT contacts, minimum load 10VA/24Vdc; maximum load
6A/250Vac
Model
230V; 50Hz
24V; 50Hz
24V dc
13
Type
REL2
REL3
REL4
14
10-13
1
2
3
4
5
6
7
8
9
10
11
12
13
14
10-14
http://europe.hbc.honeywell.com
Applications and Dimensioning
Page
1
GENERAL
A-2
DIMENSIONING AND APPLICATION POINT OF VIEW
A-2
Characteristic Parameters
Mixing or diverting valves
Valve authority
A-2
A-3
A-4
3
DIMENSIONING
A-5
4
System 1, 2-way valve with primary pump
System 2, 3-way mixing valve with primary pump
System 3, Boiler, 3-way mixing valve
System 4,
System with constant flows in primary and secondary circuits
System 5, System with constant primary and secondary flows
System 6, 2-way valve with primary pump water/water
System 7, 2-way valve with primary pump water/(domestic) water
A-6
A-6
A-6
CALCULATION EXAMPLES
A-9
Formulas
General
Guide for quick estimates
Calculations
Explanation Examples
A-9
A-9
A-9
A-10
A-11
A-7
A-7
A-8
A-8
2
5
6
7
8
9
10
A
12
13
14
Applications and Dimensioning
1
2
3
1. GENERAL
Control valves are these devices in an control loop which are,
operated by a controller signal, steering the size of energy
(using media water or steam).
You find this control devices in most heating, ventilating and
air-conditioning systems. The right selection is very important
for the controllability of the specified control loop and customer satisfaction.
The control device (valve and actuator) should be selected
accordingly to the design requirements of the application and
should result in a linear coherence between the output signal
and the control variable.
4
5
6
7
2. DIMENSIONING AND
APPLICATION POINT OF VIEW
If the system is to be prepared for connection to a district
heating network, space reheaters (radiators, convectors and
heating coils) should be connected with 2-way valves,
according to system 1 or 2, and dimensioned for water temperatures of 80°C/40°C, at the prevailing outdoor temperature.
In case air reheaters are dimensioned for a return temperature of 50°C, the air heater group must always be connected
to the boiler in a bypass configuration,with an automatically
controlled 3-way valve. This will ensure a sufficiently high
return temperature. If air heaters are to be connected to a
district heating network, their temperature and pressure
specifications must be suitable for such operation.
If there is no likelihood of later connection to a district heating network, the system should be dimensioned for 80°C/
60°C operation, at the prevailing outdoor temperature.
The heaters should be connected with a 2-way valve, in a
bypass configuration (system 2), which ensures calculation
through the boiler, or with a 3-way valve (system 4). Select
the configuration that gives the lowest system cost.
Air reheaters for outdoor air or a mixture of outdoor air and
return air should always be fitted with circulation pumps, to
prevent freezing. If such air heaters are installed, a freeze
protection thermostat should be installed in the lowest water
pipe, which, in case of freezing risk, automatically stops the
supply air fan and closes outdoor air dampers.
2.1 Characteristic Parameters
KV - Value
The KV - value is showing the capacity of media flow of a
8
valve. It characterises the volumeflow in [m3/h] of water by
measuring a differential pressure of 1bar.
CV - Value
In the USA, the CV - Value is normally used and is releated to
the volumeflow in [gal/min] by having a differential pressure
over the valve of 1 [lb/sq in].
9
K V = 0 ,86 ⋅ C V
10
/ C V = 1, 17 ⋅ K V
KVS - Value
By using the Kvs - Value, the Kv - Value is related to a Stroke
of H = 100%.
A
Kvr - Value
The Kvr - Value describes the smallest Kv - Value, where the
inclination tolerances of the valve characteristics are just fit.
Rangeability Sv
12
The rangeability Sv is charaterizing the relation between
Kvs - Value and Kvr - Value.
Sv = Kvs / Kvr
13
Calculation with KV - Value (Medium Water)
K V = V ⁄ ( ( ∆p v ) )
14
∆p v = ( V ⁄ k v )
2
V = k v × ( ∆p v )
V = Volumeflow in [m3/h]
∆pv = Differential pressure in [bar]
A-2
http://europe.hbc.honeywell.com
Applications and Dimensioning
2.2 Mixing or diverting valves
Conversion for other media
kV
ρ= V × -------∆p v
ρ = Density in [kg/dm ]
3
In applications where water/glycol mixtures are needed,
this is mainly used for heating recovery systems in air/
water applications a conversion is needed for the differences
in density of the glycol/water mixture. This mixtures are used
to reduce the temperature for freezing of the heat exchanger
by the outside air.
Attached you find some values for the density of water/
glycol mixtures:
1
As pointed out earlier, 3-way valves are used in order to minimize upsets in pressure and flow balances in the system.
In every control circuit there is a mixing and a diverting point.
In new constructions, the valve is installed in the mixing
point. When renovating old installations, the diverting valve
should be retained, if the circuit was so designed originally.
M
V1
2
3
A
AB
B
a) Density of Propylenglycol/Watermixture
C
(Sample: Hoechst Antifrogen L)
Values given in ρ [kg/dm3]
4
q
Fig. 1: 3-way valve as a diverting valve
VOL. % OF ANTIFROGEN L
16%
25%
38%
47%
100%
-20°C
-
-
1.0500
1.0618
1.0766
-10°C
-
1.0323
1.0472
1.0582
1.0710
0°C
1.0184
1.0302
1.0438
1.0538
1.0647
10°C
1.0168
1.0275
1.0400
1.0487
1.0576
20°C
1.0149
1.0241
1.0357
1.0431
1.0500
30°C
1.0111
1.0200
1.0305
1.0369
1.0421
C
6
B
q
AB
A
V1
M
Fig. 2: 3-way valve as a mixing valve
7
2.2.1 Pressure drop across 3-way valves
The pump pressure and the pressure drop across the 3-way
valve are often confused. 3-way valves always have som
water path open, which means that the total pressure from
the pump does not affect the mixing valve.
b) Ethylenglycol/Watermixture
(Sample: Hoechst Antifrogen N)
Values given in ρ [kg/dm3]
8
Which pressure drop affects the valve plug?
20%
27%
39%
52%
100%
-20°C
-
-
1.0820
1.1045
1.1695
-10°C
1.0400
1.0570
1.0790
1.1010
1.1630
0°C
1.0385
1.0545
1.0755
1.0970
1.1560
10°C
1.0360
1.0510
1.0715
1.0920
1.1495
20°C
1.0330
1.0475
1.0670
1.0870
1.1425
30°C
1.0290
1.0430
1.0620
1.0815
1.1360
Ignore pressure drops in pipes and pipe bends. Close path B
of valve VI. The flow from the diversion point C, through the
balancing valve V3 is zero. There can be no pressure drop in
this line. This means that the same pressure prevails in diversion point C and at plug B. The flow from point C passes
through the load, L and valve port A.
∆ Pp
9
10
∆ P2
C
Pc
V2
V3
A
∆ Pc
VOL. % OF ANTIFROGEN N
TEMP.
5
∆ P3
TEMP.
C
B
AB
M
12
V
A
∆ PA
13
Fig. 3: Pressure drops in typical mixing valve circuit
The valve has been selected, so that its pressure drop will be
∆pA, for a given flow. For the same flow, the pressure drop
across the load will be ∆pL.
A-3
14
Applications and Dimensioning
Pressure at plug A: pA = pc - ∆pc - ∆pA
B
2
b. Mixing three way valve
Port A: Pipes CA + pressure drop across G.
Port B: CB.
q=0
1
AB
A
M
A
V
AB
B V
M
3
G
C
Fig. 4: 3-way valve with water path A open
C
B
4
Fig. 7: Mixing three way valve
AB
A
β=
q=0
V
5
M
c. Diverting three way valve
Fig. 5: 3-way valve with water path B open
6
∆pV
∆pV + ∆pG + ∆pΑC
2.2.2 Pressure drop across the valve plug
Port A: Pipes AD + CE
Port B: BC
.
∆Pplug = pΒ − pΑ → pc − ( pc − ∆pc − ∆pA )
7
8
9
10
A
∆Pplug = ∆pc + ∆p A
AB
A
V
B
*
G
The same reasoning applies, when plug A is closed. The
above shows that the 3-way valve is only affected by the
pressure drops in the circuit, where the flow is varied by the
mixture valve.
The pressure drops that load a 3-way valve is equal to the
total pressure drop in the open flow path, calculated from the
point at which the flow is divided (C) to the common valve
port (AB).
C
β=
The valve authority should only be calculated for that part of
the circuit, in which the flow is effected by the valve. Thus,
the balancing valve V2 in Fig.3 does not effect the valve
authority.
The 3-way valve effects the flow in the following parts of the
pipe network (marked with thick lines in the figures):
C
E
Fig. 8: Diverting three way valve
2.3 Valve authority
∆pV
∆pV + ∆pΑD + ∆pCE
d. Mixing three way valve
Port A: Pipes AE + CD.
Port B: CB.
a. Diverting three way valve
D
C
Port A: Pipes AC + pressure drop across G.
Port B: CB.
STA-D
*
G
C
12
M
C
V B
G
AB
C
A
E
M
B
13
V
A
M
Fig. 6: Diverting three way valve
14
∆pV
β=
∆pV + ∆pG + ∆pΑC
A-4
Fig. 9: Mixing three way valve
AB
http://europe.hbc.honeywell.com
β=
∆pV
∆pV + ∆pΑE + ∆pCD
For the marked parts the pressure drops in Fig. 8 and
Fig 9 are relatively small. The autority of 3-way valves is
therefore often close to 1. But to maintain correct characteristic in control valve V, don‘t select it for a ∆p below 3kPa.
Applications and Dimensioning
3. DIMENSIONING
1
System 1
System 5
2
M
M
V1
A
AB
B
C
3
C
q
Fig. 10: Preheating coil which can be subject to freezing
System 2
Fig. 14: System with constant primary and secondary flows
4
System 6
5
M
M
6
C
E
C
C
7
Fig. 11: Reheating system in cases not subject to freezing
Fig. 15: Fig.15 Heating system connected to district heating
network
8
System 3
M
G
System 7
9
C
10
E
M
Fig. 12: Radiator circuit connected to boiler heating plant
A
Fig. 16: Domestic hot water system connected to district
System 4
heating network
12
C
13
M
Fig. 13: System with constant primary and secondary flows
14
A-5
Applications and Dimensioning
1
3.1 System 1, 2-way valve with primary
pump
• With variable flow, this configuration does not provide an
even temperature in the air coil.
• With small coils also risk for hunting at constant supply air
temperature control.
∆ PL
M
2
tr
tr
3.2.2 Valve sizing
V
*
3
∆pv ≥ ∆pc
ß ≥ 0.5 i.e.
C
∆p v = ∆ H − ∆p c
P
∆H
qp
tp
ts
qs
Kv =
Fig. 17: 2-way valve with primary pump
4
5
6
36 ⋅ q
( kPa,1 / s )
∆pv
3.1.1 Functions and characteristics
3.2.3 Flow Characteristic
• Primary circuit: flow control, constant temperature
• Secondary circuit: temperature control, constant flow
• Connected to district heating network, with a requirement
on low return temperature
• Heating installation, with long pipe runs
• Large air heaters, not subjected to freezing
A - AB = EQ% (Logarithmic)
B - AB = linear (LIN)
3.3 System 3, Boiler, 3-way mixing valve
∆ Pv
qg C
F
3.1.2 Valve sizing
H
A
Thermal equilibrium
7
q p ⋅ (t p − t r ) = q s ⋅ (t s − t r )
9
∆H
C
E
D
qp
G
tr
qs
Fig. 19: Constant flow in boiler
The pressure drop in the pipes of the primary side is negligible.
36 ⋅ q p
ts
AB
B V
P1
∆pv ≈ ∆H
Kv =
P2
G
Dimension the pump for the flow in the secondary circuit,
and the total pressure drop in the circuit.
8
M
( kPa ,1 / s )
3.3.1 Functions and characteristics
• Primary circuit: variable flow, constant temperature
• Secondary circuit: constant flow, variable temperature
• System with local boiler
3.1.3 Flow Characteristic
10
A
3.3.2 Valve sizing
∆H = 3-5kPa Eq% (Logarithmic)
∆H = 5-10kPa Modified linear (MOD.LIN)
ß=1
3.2 System 2, 3-way mixing valve with primary pump
∆pv > ∆ GD + ∆ CH
not less than 3 kPa
∆ Pv
Kv =
M
12
A
AB
V
36 ⋅ qs
( kPa,1 / s )
∆pv
∆H
C
∆ Pc
B
13
3.3.3 Flow Characteristic
Linear
The resistance of pipe CD is considered to be negligible.
q
Fig. 18: 3-way mixing valve with primary pump
14
3.2.1 Functions and characteristics
• Primary circuit: constant flow
• Secondary circuit: variable flow, constant temperature
• The coil must not be subjected to freezing.
A-6
http://europe.hbc.honeywell.com
Applications and Dimensioning
3.4 System 4, System with constant flows
in primary and secondary circuits
P2
t gs
C
∆ H1
P1
qs
D
qg
∆H
*
∆ Pv
A
E
AB
tr
ts
M
∆ Pv
• Primary circuit: constant flow, temperature control
• Secondary circuit: constant flow
• This configuration is used for large air cooling and heating
coils
• It is suitable for connection to large boilers, where each
object is individually controlled.
)
qg ⋅ tgs − tgr = qs (ts − tr )
tgs > ts
3.4.2 Valve sizing
Pipe sections C-D and E-A are the part of the pipe network,
in which the flow is affected by the valve.
Valve authority, ß = 1.0.
3.4.3 Flow characteristic for V:
Κv =
P2
2
AB qs
BV
qp A
qg
ts
C
3
tr
3.4.1 Functions and characteristics
∆pv > 3kPa
D tp
∆ Pp
∆H
C
Fig. 20: Coil in air handling unit
qgs < qs
P1
tg
M
1
B V
t gr
(
3.5 System 5, System with constant primary and secondary flows
(Linear)
36 ⋅ qs
( kPa,1 / s )
∆pv
tr
E
C
Fig. 21: Constant flow in primary/secondary circuit
4
3.5.1 Functions and characteristics
• Primary circuit: constant flow, constant temperature
• Secondary circuit: constant flow, variable temperature
• Pressure changes in the primary circuit do not affect the
secondary circuit, which also means that the secondary
circuit cannot affect the primary circuit.
• This configuration is used for large systems, with multiple
mixing valve - bypass groups.
5
6
3.5.2 Valve sizing
Pipe section D-E is the part of the pipe network, in which the
flow is affected by the valve. The pressure drop in D-E is
negligible, which means that the authority of the valve,
ß = 1, but the valve must be designed for a pressure drop of
at least 3kPa.
7
8
3.5.3 Flow characteristic for V:
∆pv ≥ 3kPa
(Linear)
9
36 ⋅ qs
( kPa,1 / s )
Κv =
∆pv
10
A
3.4.4 Balancing
• Close port A-AB of V and start pumps, P1 and P2.
• Adjust STAD-S, so that the flow through the coil is correct.
• Open port A-AB of V fully.
• Adjust STAD-G, so that the designed primary flow is
obtained.
12
13
14
A-7
Applications and Dimensioning
1
3.6 System 6, 2-way valve with primary
pump water/water
∆Pv
2
tr
V
∆ PE
E
C
C
∆H
4
ts
Fig. 22: Heat exchanger, heating system
3.6.1 Functions and characteristics
6
7
• Flow control.
• Heating system (radiator groups and air heaters) connected to district heating network, with a requirement on
low return temperature.
• Heat exchanger between primary and secondary circuits,
is required if static pressure and temperature on primary
side are incompatible with equipment in secondary circuit.
• Small air heaters, not subjected to freezing.
3.6.2 Valve sizing
8
9
∆pv = ∆Η − ∆pE
Κv =
β=
36 ⋅ q
( kPa,1 / s )
∆pv
∆pv
≥ 0.5
∆Η
Flow characteristic: EQ% (Logarithmic)
10
3.7 System 7, 2-way valve with primary
pump water/(domestic) water
A
ts
∆ Pv
12
∆ PE
E
M
∆H
13
V
q tr
Cold water
Fig. 23: Heat exchanger, hot water
3.7.1 Functions and characteristics
14
β=
36 ⋅ q
( kPa,1 / s )
∆pv
∆pv
≥ 0.5
∆Η
Valve characteristic: EQ% (Logarithmic)
q
5
∆pv = ∆Η − ∆pE
Κv =
M
3
3.7.2 Valve sizing
• Flow control.
• Throttling away of excess pressure
• Domestic hot water system connected to district heating
network
• System with requirements on low primary return temperature.
A-8
http://europe.hbc.honeywell.com
Applications and Dimensioning
4. CALCULATION EXAMPLES
Valve flow coefficient
4.1 Formulas
LIQUID
Heating:
Ρ = 1.3 ⋅ qΑ ⋅ ∆Τ
G = 1.59 ⋅ Ρ
Air
Steam
SATURATED
STEAM
Ρ = kW
q = m3/h
qw = 1/s
Temperatures (standard values):
Heat exchanger, primary, district heating
Heat exchanger, other
Heat exchanger, radiators, low flow system
(80-30K)
∆Τ = 40K
∆Τ = 20Κ
∆Τ = 50Κ
∆Τ = 5 − 10Κ
Heating demands of dwellings:
New buildings
Well insulated buildings
Not very well insulated buildings
Poorly insulated buildings
Cellars
40 W/m2 living area
50 W m2 living area
60 W/m2 living area
100 W/m2 living area
15 W/m2 living area
Calculation of valve leakage using the
temperature method:
M
tg
G
∆p ≥ 0.5 ⋅ p1
∆p < 0.5 ⋅ p1
4
Κv =
C
qb
tr
tr
Κv =
G
11.35 ⋅ p1
G
22.7 ⋅ ∆p ⋅ p2
Κv =
G⋅k
11.35 ⋅ p1
Κv =
k = 1 + 0.0012 ⋅ t s
G⋅k
22.7 ⋅ ∆p ⋅ p2
qg
qs
=
ts − tr
t g − tr
qb t s − t g
=
qs t r − t g
6
8
3
p = Density, kg/dm (note units)
q = Liquid flow rate, m3/h
G = Steam flow rate, kg/h
ts = Steam superheating temperature, °C
k = Correction factor for superheated steam
9
10
Valves connected in series
1
(Κ v )
2
=
1
( Κ v1 )
2
+
A
1
(Κ v 2 )
2
Fig. 24: Calculation of leakage using the temperature
method
5
7
Kv = Flow coefficient, m3/h, at ∆p = 1 bar
Cv = Flow coefficient, US gallons/min, at ∆p = 1psi
p1 = Pressure before valve, bar absolute
p2 = Pressure after valve, bar absolute
pv = Pressure drop across valve, p1 - p2, bar
Κ v = Κ v1 + Κ v 2 + Κ v
qs
tr
3
SUB-CRITICAL
PRESSURE DROP
Valves connected in parallel
ts
qg
SUPERHEATED
STEAM
2
CRITICAL
qΑ = m3/h
G = kg/h
C v = 117
. ⋅Κv
PRESSURE DROP
STEAM
Units and designations:
Heat exchanger, cooling coils
q⋅ p
Dpv
Kv =
Ρ = 4.18 ⋅ q w ⋅ ∆Τ
Ρ = 116
. ⋅ q ⋅ ∆Τ
Water
1
12
4.2 General
When designing HVAC-systems, often uncertainty exists
regarding the magnitude of the pressure drop across various
components. The following information will suffice for rough
estimates, although the manufacturers specifications always
should be consulted when making accurate calculations.
4.3 Guide for quick estimates
The following are commenly encountered pressure drops:
∆pΡ =
∆pS =
pressure drop on primary side of heat exchangers.
pressure drop on secondary side of heat
exchangers.
A-9
13
14
Applications and Dimensioning
4.4 Calculations
1
Water heater
2
(tap water)
∆pP = 2 − 7kPa,20kPa,max.

∆ps = 10 − 30kPa,50kPa,max.
4.4.1 Example 1
∆Pv
M
V
3
Heat exchanger
(radiator network,
air conditioning,
4
snow melting)
Radiators without radiator valves
5
Low flow systems
with radiator
Convectors
Fan coils
8
Heating/cooling coils
Boilers
single family houses
Boilers
apartment houses
9
Water meter
district heating
Filters
10
Pipe resistance
copper pipe
A
12
∆H =
100kPa
∆pP = 20 kPa.max.


∆p = 15kPa.max.
 s
∆p = 0.5 kPa
Dp = 10 kPa
∆ p = 10 kPa
E
Fig. 25: Example 1
To obtain a flow in the primary circuit of 1.39 l/s a pressure
drop of 10kPa is required. A pressure drop of 100kPa is
available. Calculate the flow coefficient Kv and the authority β
of the valve.
Solution
6
7
q = 1,39 l/s
Pipe resistance
steel pipe
Pipe resistance total in a
substation
(district heating)
Dp = 5 − 20 kPa
pv = 100 - 10 = 90kPa
Dp = 5 − 20 kPa
K =
v
∆p = 5 − 20kPa
Κv = 5.27
∆p = 1 − 5 kPa
Select Κv = 6.3
∆p = 0.5 − 10 kPa
∆pP = 15 kPa
∆p = 15 kPa
36 ⋅ q 36 ⋅ 1.39
=
= 5.27 (kPa. 1 / s)
90
∆p
+40% = 7.38
-20% = 4.2
Valve authority, β
Κv = 6.3
q = 1.39 l/s
2
5.27 
Dp = 90 ⋅ 
 = 63 kPa
 6.3 
v
63
= 0.63
100
∆p = 0.2 kPa / m
β=
∆p = 0.4 kPa / m
Pressure drop to create in the balancing valve
∆p = 10 kPa
(a good value as β should be >0.5)
DH = Dpv − DpE = 100 − 63 − 10 = 27kPa
4.4.2 Example 2
P
∆ p=
20kPa
∆ H=100kPa
13
V
M
∆ Pv
14
Fig. 26: Example 2
An air preheater must deliver 100kW.
• Sizing of V.
• Sizing of circulating pump, P.
• Calculate the authority of the valve.
A-10
http://europe.hbc.honeywell.com
+
P=100
Applications and Dimensioning
Valve authority, β
Solution
P = q ⋅ ∆T ⋅ 1.16 kW
β=
100 = q x (100-35) x 1.16
q = 1,3 m3/h = 0,371 l/s
The pump P should be dimensioned for the flow, q = 1.3 m /
h, and ∆p = 20kPa, plus the remaining pressure drops in the
circuit. Select the nearest larger pump and compensate with
STAD-S.
4.4.3 Example 3, Control valve V
The pump P provides a constant flow in the secondary circuit and overcomes drops in the secondary circuit.
V should be dimensioned for the entire pressure drop,
∆p = 100 kPa.
36 ⋅ q 36 ⋅ 0.37
Kv =
=
= 1.33 (kPa, l / s)
DH
100
Valve authority, β = 1.0
Choose right Kv
Select STA-P
4.4.4 Example 4, Heating, radiator circuit
Heat demand
50 apartments, each with an average area of 65 m2.
A heating demand of 60W/m2 gives
P=50 .65 .60 = 195 kW
Similarly, a cellar area of 600m2, with a heating demand of
15 W/m2, gives 9kW.
P tot = 195 + 9 = 204kW
4.4.5 Example 5, Radiator valve V1
Ρ = q ⋅ ∆Τ ⋅ 1.16
204 = q ⋅ (100 − 50) ⋅ 1.16
q = 3.5m / h = 0.97l / s
3
∆pP = 35kPa
∆p = 25kPa
∆pv = 150 − 35 − 25 = 90 kPa
Κv =
36 ⋅ q 36 ⋅ 0.27
=
= 3.68 ( kPa, l / s )
90
∆p v
+40% = 5.2
Basic Kv - value = 3.68
-20% = 2.9
Select:
Kv = 4.0
EQ% (Logarithmic) characteristic.
2
Can the primary valve close off the maximum differential
pressure?
Is ∆pc (maximum permissible ∆p across a closed valve)
lower than the maximum value permitted by the combination of actuator, valve type and valve size? If not, the valve
leakage will be excessive (>0.05% of Kv).
3
4
4.5 Explanation Examples
4.5.1 Medium Water
Drawing Line in Fig. 27
Given:
-Volume flow V100 = 6.0m³/h
-Pressure drop ∆pv = 0.9bar (= 90kPa)
Searched for: -kvs - value
5
6
The point of intersection of the two drawing lines
shows the kv - value 6.3.
Result: Select a valve with kvs = 6.3m³/h
7
4.5.2 Medium Steam
Example A: Drawing Line 1 in Fig. 28
Given: -Max. mass flow of saturated steam GS = 370kg/h
-Primary valve pressure p1 = 2.8bar (absolute)
-Pressure drop ∆pv = 0.6bar
Searched for: kvs - value
From the point of intersection of p1 = 2.8bar with
∆pv = 0.6bar move horizontal into the kv - value area.
Then from the mass flow of saturated steam GS = 370kg/h
move vertically downwards.
The point of intersection with the horizontal and vertical
drawing line is between kv - value 13.7 and 16.
8
9
10
Result: Select a valve with kvs = 16.0m³/h
Pressure drop in the circuit
Water meter and piping
90
= 0.6
150
Valve close-off pressure
3
Heat exchanger
1
Example B: Drawing Line 1 in Fig. 28
Given: -Max. mass flow of superheated steam
GS = 1300kg/h
-Primary valve pressure p1 = 1.2bar (absolute)
-Pressure drop ∆pv = 0.35bar
-Superheat ∆t = 100°C
Searched for: kvs - value
A
12
From the point of intersection of p1 = 1.2bar with
∆pv = 0.35bar move horizontal into the kv - value area.
Then from the mass flow of superheated steam
GS = 1300kg/h follow parallel to the lines and move vertically
upwards to the point of intersection with the horizontal line
for the superheat ∆t = 100°C.
From this point move vertically upwards.
The point of intersection with the horizontal drawing line
shows the kv - value 100.
Result: Select a valve with kvs = 100m³/h
A-11
13
14
Applications and Dimensioning
1
DIAGRAM 1: kVS - Dimensioning, Medium Water
water column
10
50
20
100
200
500
1000
2000
5000
10000
20000
50000
100000 mmWS
2
500000
500,0
3
300000
30
=6
200,0
200000
k VS
400
4
100,0
100000
250
160
50,0
5
50000
40000
100
30000
63
20,0
20000
15000
40
6
10,0
6,0
5,0
7
10000
25
16
5000
10
3000
6,3
2,0
2000
8
1500
4,0
1,0
9
1000
2,5
700
600
500
1,6
0,5
400
1,0
300
3
0,6
0,2
10
200
0
0,4
0,1
100
5
0,2
A
13
14
40
30
20
1
2
3
0,1
0,2
0,3
4
5
10
0,5
1,0
20
30
40 50
100
200
300
500
1000
2000
5000
5,0
10
20
30
50
90 100
200
500
10
10000 mbar
1000
pressure drop ∆ p vA-AB
Fig. 27: Example for kVS-dimensioning, medium water
A-12
http://europe.hbc.honeywell.com
waterflow Q (l/h)
waterflow Q (m3 /h)
12
50
kPa
Applications and Dimensioning
DIAGRAM 2 kVS - Dimensioning, Medium Steam
1
superheated steam, G (kg/h)
saturated steam, G s (kg/h)
superheating ∆t in K
2
3
4
5
6
7
8
9
A
prepressure absolute p 1 in bar (kPa)
r
su
es
r
p
e
op
dr
∆
p
v
in
r
ba
10
12
13
14
cri
tic
al
p re
s
su
re
r
ati
o
Fig. 28: Example for kVS-dimensioning, medium steam
A-13
Applications and Dimensioning
1
2
Applicable Literature:
•
Technikum Luzern: ”Arbeitsunterlagen Heizungstechnik
(Abt. HLK)”
• Recknagel/Sprenger ”Taschenbuch für Heizungs- und
Klimatechnik”
• - Honeywell ”Engineering Manual of Automatic Control”
3
4
5
6
7
8
9
10
A
12
13
14
A-14
http://europe.hbc.honeywell.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising