Xtralis VESDA LCD Programmer
Xtralis VESDA LCD Programmer
Programming Functions
• System configuration
• Detector zone configuration and set up
• Detector zone control
• System status
• Smoke Threshold and Detector
Sensitivity settings
• Event Log interrogation
• Commissioning and testing
• Set date and time
• Referencing
• AutoLearn™
Description
The Programmer Module allows direct access to all VESDAnet devices on
an Xtralis VESDA smoke detection system. It allows configuration and status
reporting of detectors, displays and interfaces and is required when installing,
commissioning and maintaining a VESDA network. By incorporating a user
friendly menu, navigation through the comprehensive features of VESDAnet
is convenient and simple.
The programmer module is available as a hand-held device (with included
DB15 serial cable) or can be mounted into a Xtralis VESDA VLP or Xtralis
VESDA VLS detector, a remote mounting box or a 19 inch sub rack.
The two rows of large push buttons enable the user to log ON and navigate
through the menu trees to the various command and parameter setting
functions. The top row of keys are called “Soft Keys” and are assigned
programming options appropriate to the screen being viewed.
Some of the parameters that can be accessed via the programmer
include device status reporting, zone number and name allocation, flow
normalisation, alarm threshold setting (day, night, weekend), initiation of
AutoLearn, wiring order, relay testing and event log review.
Up to 14 assigned Users or Administrators with an individual 4 digit Personal
Identification Number (PIN), and one Distributor, can log onto a VESDAnet
system under one of three levels of access which are password protected:
• User (USR) is only able to view parameters, check status, alarms and reset
the system.
• Administrator (ADM) has access to most commands and programming
parameters.
• Distributor (DST) is the topmost level and has unlimited access to all
commands and parameters in the system.
• Lost PIN numbers can be overcome by obtaining a once only pass number
from your Xtralis VESDA dealer.
The programmer automatically logs OFF when not in use for more than 10
minutes. The user is prompted with a beeping sound at 1 minute and at 15
seconds before log OFF. Any key may be pressed to cancel the automatic log
OFF process.
• Passwords and user Configuration
• System fault diagnostic
Features
• User friendly menu system
• Supports multiple languages
• Single point access to entire
VESDAnet system
• Alarm and fault simulation
• Shows wiring order
• Locates communications failures
• Password security
• Hand held or remote mounting
• Automatic Logoff when inactive
• Backlit LCD screen
Listings/Approvals
• UL
• ULC
• FM
• LPCB
• VdS
• CFE
• ActivFire
• AFNOR
Xtralis VESDA LCD Programmer
Specifications
Screen Display Size:
70 mm x 37 mm (2.75 in x 1.45 in)
Full Graphic display
Large characters
8 lines, 21 characters per line
Adjustable backlit screen with contrast control
Supply Voltage: 18 to 30 VDC
Module
Hand Held
Remote
Power (W)
@ 24 VDC
Min
Max
1.08 W
1.44 W
1.68
1.2
Current (mA)
@ 24 VDC
Min
Max
45 mA
60 mA
70 mA
50 mA
Dimensions
(WHD)
mm
in
98 x 130 x 30
3.9 x 5.1 x 1.21
105 x 135 x 60
4.1 x 5.3 x 2.4
140 x 150 x 90
5.5 x 5.9 x3.5
Terminal connector to Head
Processor Card or to expansion
connector on another Xtralis
VESDA device
15 pin D-type connector.
VESDAnet cable required to
connect to detector or remote
VESDAnet socket
RS485 VESDAnet field wiring to
Screw terminal blocks
(0.2–2.5 mm2, 30–12 AWG)
Connections
Push Button Keys:
2 Rows x 4 keys, each 19 mm x 12 mm
(0.75 in x 0.50 in)
Security Access:
3 characters User lD
4 digit Personal Identification Number (PIN) per User
Remote Mounting Box
A
F
G
E
Dimensions
mm in
140 5.5
150 5.9
70 2.75
60 2.36
44.5 1.75
48 1.9
23 0.9
25 0.98
27.5 1.1
16.5 0.65
25 0.98
6.4 0.25
1.6 0.06
23 0.91
26 1.0
(6) “O” DIA. KNOCKOUTS:
-2 TOP, -2 BACK
AND 1- EACH SIDE (2)
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
TOP VIEW
C
D
J
N
EQUAL
I
H
J
K
B
(4) “L” DIA.
MOUNTING
HOLES
M
I
EQUAL
(2) “L” DIA.
ANCHOR
HOLES
FRONT VIEW
SIDE VIEW
19” Sub Rack
Dimensions
mm in
A 482 19
B 128 5
C 120 4.75
21 0.82
D
E 97.2 3.82
6.4 0.25
F
16 0.62
G
14 0.56
H
190 7.50
I
36 1.4
J
7 0.28
K
10 0.39
L
8 0.31
M
N 440 17.37
O 102 4
P 98.5 4
TOP VIEW
(TYP.)
FRONT VIEW
www.xtralis.com
The Americas +1 781 740 2223 Asia +852 2916 8894 Australia and New Zealand +61 3 9936 7000
Continental Europe +32 56 24 19 51 UK and the Middle East +44 1442 242 330
The contents of this document are provided on an “as is” basis. No representation or warranty (either express or implied) is made as to the
completeness, accuracy or reliability of the contents of this document. The manufacturer reserves the right to change designs or specifications
without obligation and without further notice. Except as otherwise provided, all warranties, express or implied, including without limitation any
implied warranties of merchantability and fitness for a particular purpose are expressly excluded.
This document includes registered and unregistered trademarks. All trademarks displayed are the trademarks of their respective owners.
Your use of this document does not constitute or create a licence or any other right to use the name and/or trademark and/or label.
This document is subject to copyright owned by Xtralis AG (“Xtralis”). You agree not to copy, communicate to the public, adapt, distribute, transfer,
sell, modify or publish any contents of this document without the express prior written consent of Xtralis.
Doc. no. 11956_09
Inactivity Time Out:
10 minutes (Defaults to log on screen)
Beeps at 1 minute and then 15 seconds before
Logoff
Part: 17875
Number of User Levels:
10 USR
3 ADM
1 DST
Default ID:
USR = User (Operator level)
ADM = Administrator (Access most functions)
DST = VESDA Distributor (Access all functions)
Operating Conditions:
Tested to: -10°C–55°C (14°F–131°F)
Recommended Detector Ambient: 0°C–39°C
(32°–103°F)
Humidity: 10%–95% RH, non-condensing
System Functions Accessed:
Status of software version
Descriptive Alarms & Faults
Smoke & Flow readings
Push-Button lockout
Display name (21 chars)
Alarm Thresholds (Alert, Action, Fire 1 & Fire 2)
Alarms delays (0–60 seconds)
Day/Night/Weekend/Holiday Options
Event Log (up to 18,000 events)
Zone number and name (21 chars)
Pipes in use (pipe 1 to 4)
Aspirator Speed & Flow control
Confirmation of filter change
Relay configuration
Referencing
Auto Learn™
Addressed Devices:
250 Xtralis VESDA devices maximum
Xtralis VESDA addressed Devices:
Xtralis VESDA VLP Detectors & Displays
Xtralis VESDA VLS Detectors & Displays
Xtralis VESDA VLC Detectors & Displays
Xtralis VESDA VLF
with Vnet card
Detectors & Displays
HLI (High Level Interface)
Relay modules Remote Relays
Ordering Information:
Remote Programmer
Recessed Mounting
Kit (Optional)
Hand-Held Programmer 19 inch Sub Rack
Configuration VRT-100
VSP-012
VHH-100
contact Xtralis
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising