Powerware® 9120
Powerware® 9120
Snapshot
Features
True double conversion online
technology give you protection
from all nine power problems
Power Rating: 700-3000VA
Voltage: 120 and 230 Vac
Frequency: 50/60 Hz
(auto-sensing)
Configuration: Tower
Simple installation and operation
Intuitive LCD screen provides realtime updates of UPS status, power
usage, battery run time remaining
and other critical UPS parameters
Hot-swappable batteries
As businesses become increasingly dependent
The Powerware 9120’s communications are
Extended run time capability with
external battery modules
on technology for their fundamental operation,
flexible, allowing for local, network or remote
the need for system availability is of paramount
monitoring and management. The Powerware
importance. The Powerware 9120 UPS is designed
9120 includes the latest version of Powerware’s
for those applications that need maximum
Software Suite, which provides power monitoring
protection in the 700 VA – 3kVA range. With
and shutdown software.
Complete offering of power
management software included
to ensure data integrity
User-selectable High
Efficiency Mode
Warranty (US and Canada)
- 2-year limited warranty
- 10-year pro-rated warranty
- $25,000 load protection guarantee
its high-frequency, double-conversion online
topology, providing nonstop clean sine wave
Simple plug-and-play operation makes installing
power, advanced communications and space-
the Powerware 9120 fast and easy. A single
saving tower design, the Powerware 9120 is the
button touch provides clean, uninterruptible
ideal solution for networks, web servers, telecom-
power to the critical load. An intuitive LCD screen
munications applications and other critical
provides real-time updates of UPS status, power
electronic equipment.
usage, battery run time remaining, and other
critical UPS parameters.
In addition to its proven design, the Powerware
9120 offers Advanced Battery Management
With the Powerware 9120, Powerware delivers a
(ABM®)
best-in-class power solution for maximum system
and sophisticated communications to
provide maximum system availability. ABM uses
availability, and peace of mind.
a three-stage charging technique that not only
doubles battery service life, but optimizes battery
charge time and provides 60-day notification of
the end of useful life for the batteries.
Software
Powerware Recommends
> Powerware
Software Suite
ensures data integrity;
free updates on
www.powerware.com
Connectivity
> Expansion
chassis with
Modbus card
> Web/SNMP card
> Relay card
Service
> Gold Plan
> Gold Plan
Plus
System Solutions
> Extended battery
modules (EBM)s
Powerware 9120 Features
Front Panel Display
Series 9 Power Protection
Informative user interface with LCD, four LED and audible alarms.
True Online Design
True online systems such as the
Powerware 9120 are the only type
LCD
of UPSs that completely isolate connected equipment from all 9 of the
most common power problems:
Scroll meters/
1
Select UPS settings
2
3
Power Failures
Starts Up/Shuts down
4
the UPS
Scroll UPS settings/
Select UPS setting parameter
Power Sags
Power Surges
Undervoltage
1
UPS On
2
On Battery
3
On Bypass
4
Alarm
Electrical
Line Noise
Overvoltage
Loads Segments, Network Transient Protector and Remote Emergency
Power Off (REPO) Port
Frequency
Variation
The Network Transient Protector
isolates your modem, fax
machine, and other electronic
equipment from “back door”
power surges
Switching
Transient
Harmonic
Distortion
Load Segments are groups of
receptacles that can be independently controlled and extend
battery backup times for critical
equipment.
To preserve battery power for
more critical equipment connected to Load Segment 1, shut
down Load Segment 2 supporting less critical equipment.
Even when presented with the most
severe of these power problems, the
Powerware 9120 output remains
within a remarkable ±2% of nominal
voltage, meaning that your critical
system always receives clean power.
Shut down and power up Load
Segments in user defined
sequence.
In addition, the Powerware 9120
transfers to battery with no break in
power, making it the perfect UPS for
equipment in environments plagued
by poor power.
Powerware 9120 1000
Shown
The REPO port enables you to shut down the
UPS and connected equipment from a
remote location in an emergency.
Battery Features and Run times
Advanced Battery Management (ABM) Technology Doubles Battery Service Life
The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup time of
at least half that of new batteries. The illustration below
shows that batteries that are constantly trickle charged (as
are virtually all other UPS batteries on the market today)
reach the end of their useful life in less than half the time
of batteries charged using ABM. ABM uses a three-stage
charging technique that not only doubles battery service
Data based upon tests performed by an independent battery manufacturer
life, but also optimizes battery recharge time and provides
advanced notification of the end of useful battery life.
Hot-Swappable Batteries
You can hot-swap batteries without powering down the critical load.
This makes it possible to extend the life of your UPS without returning the unit for service.
Extended Battery Modules (EBMs)
Increasing battery backup time is as simple as plugging in an
extended battery module. Hot-swap capability on all Powerware
9120 models allow you to expand run time or replace battery modules while keeping your critical load up and running.
Powerware 9120 - 1000VA shown with
front cover removed and battery shown
sliding out.
Battery Run Time Chart (in minutes full load/half load)*
VA
Standard Internal Battery
1 EBM
2 EBMs
3 EBMs
4 EBMs
5 EBMs
700
7/18
34/70
64/140
—
—
—
1000
7/18
36/80
66/155
—
—
—
1500
7/18
29/67
56/130
—
—
—
2000
12/34
49/107
93/195
140/310
192/403
240/504
3000
6/15
30/70
57/128
87/191
120/264
148/325
*Up to 2 EBMs can be connected to 700/1000/1500VA models and up to 5 EBMs can be connected to 2000/3000VA models. Run time chart
provides typical information. Run times are approximate and may vary with equipment, configuration, battery age, temperature, etc.
Software and Connectivity Options
Foreseer
Powerware Software Suite
The industry’s most comprehensive software bundle, the Powerware Software Suite CD, is free
and included with every Powerware 9120 UPS.
Software Wizard guides you through software selection and installation
Facility & Data
Center Management
S O F T WA R E
In addition to multimedia demonstrations, product data sheets, and video clips, the Software
Suite contains the following power management software:
S U I T E
OnliNet
PowerVision
PowerVision
UPS
UPS Performance
Performance
Analysis
Analysis &
&
Monitoring
Monitoring
– LanSafe III and CheckUPS Network shutdown for UPSs
LanSafe III &
CheckUPS
Network Shutdown
for UPSs
SNMP-Based
SNMP-Based
Network
Network Shutdown
Shutdown
&
& Monitoring
Monitoring
– OnliNet (Lite / Vista / Centro): SNMP-based network shutdown and monitoring for UPSs
– PowerVision (30-day trial version): UPS performance analysis and monitoring
– Foreseer (demonstration): Facility and data center management
Communications
USB port (standard) allows UPS to communicate with Windows 98 and ME computers
RS232 Port (standard) for interface with power management software
SNMP/Web card (optional) adds direct control and monitoring capabilities in SNMP-based
networks. Ability to monitor UPS status and meters through web browser interface
Relay card (optional) adds integration to industrial environment and building management
systems, shutdown for IBM AS/400.
SNMP/Web Card shown
Rear Panels: 120V, 208V and 230V Models
PW9120 700, 120V
PW9120 1000, 120V
PW9120 1500, 120V
USB Port
Communication
Port
Fan
PW9120 2000, 120V
Communication Slot
Network
Transient
Protector
Battery
Connector
REPO Port
Four IEC-C13
Receptacles
IEC-C14 Input
Connector
PW9120 3000, 120V
PW9120 3000, 208V
PW9120 2000i, 230V
PW9120 3000i, 230V
PW9120 700i/1000i, 230V
PW9120 1500i, 230V
Technical Specifications1
Electrical Input
Nominal Voltage
Input Voltage Range
120 Vac and 230 Vac;
See Model Selection Guide
for user-selectable voltages
120V: 80 –144 Vac
230V: 120/140/160-276 Vac
>.95%
50/60Hz, Auto-sensing
45-65Hz
Fuse or circuit breaker
Input Power Factor
Operating Frequency
Frequency Range
Input Protection
Electrical Output
On Utility Voltage Regulation ±2% of nominal
On Battery Voltage Regulation ±3% of nominal
Nominal Output Voltage
Same as selected input
voltage
Output Voltage Waveform
Sine Wave
Output Voltage Distortion
<3% THD
Output Protection
Electronic overload sensing,
and circuit breaker protection
Efficiency
Online Mode: >86%;
Hi-Efficiency Mode: >90%
Communications
User Interface
LCD status screen
Audible Alarms
UPS alarm conditions,
including: On-Battery, Low
Battery, Overload, UPS Fault
Network Transient Protector In and out jack for all models.
UL497A tested
REPO Port
Meets NEC code 645-11
intent and UL requirements
Communications
One RS232 Serial Port; One
Communications Slot;
One USB Port
Communications Cable
6-foot communications cable
included
Power Management Software Powerware Software Suite
CD,free updates on
www.powerware.com
General
Topology
True online double
conversion
Diagnostics
Full System self-test on
power up
UPS Bypass
Automatic on Overload or
UPS failure < 4ms
Transfer Time to Battery
0 ms
Dimensions and Weights
See Model Selection Guide
Overload Capacity
125% for 10 minutes before
transfer to bypass; 150% for
10 seconds before transfer
to bypass
Battery
Internal/EBM Battery Type
nance free
Battery Runtime
Battery Replacement
external batteries
Recharge Time
Start-On-Battery
Environmental
Safety Certifications
EMI Compliance
Operating Temperature
Storage Temperature
Relative Humidity
Immunity
Network Transient Protector
Audible Noise at 1 meter
Altitude
Sealed, lead-acid; mainteSee Battery Runtime table
Hot-swappable internal and
<4 hours to 90% capacity
Allows start of UPS without
utility input
120V: UL1778; cUL22.2 NO.
107.1; 230V: CE marked, EN
50091-1-1 and IEC 60950
FCC Part 15, Class B (7001500), Class A (2000-3000)
230V, EN 50091-2 Class B
(700-1500), Class A (2000-3000)
0 to 400 C (32 to 1040 F)
-15 to 500 C (5 to 1220 F)
0% to 95% non-condensing
IEEE C62.41,
IEC 61000-4 -2, -3, -4, -5
UL497A
700-1000VA: <45dB; 1500VA
<50dB; 2000-3000 <52dB
3000m (10,000 ft) without
deteriorating
1. Due to continuing product improvement programs, specifications are subject to
change without notice.
Model Selection Guide
Model
Power Out
(VA/Watt)
Input/OutPut
Voltage (Vac)
Frequency
(Hz)2
Input
Connection3
120 Vac Models1
PW9120 700
700/490
120
50/60
5-15P
(4) 5-15R
PW9120 1000
1000/700
120
50/60
5-15P
(4) 5-15R,
35.5/16.1
PW9120 1500
1500/1050
120
50/60
5-15P
PW9120 2000
2000/1400
120
50/60
5-20P
PW9120 3000
3000/2100
120
50/60
L5-30P
PW9120 3000h
3000/2100
120
50/60
Hardwired
208 Vac Models
PW9120 3000
3000/2100
208
50/60
L6-20P
230 Vac Models
PW9120 700i
Output
Dimensions
Receptacles4 (H x W x D) in/mm
(4) 5-15R,
(2) 5-20R
(6) 5-20R
(4) 5-15R,
(2) 5-20R,
(1) L5-30R
Hardwired
9.6 x6.2 x16.2/
243 x 158 x 412
9.6 x 6.2 x 16.2/
(2) 5-20R
10.8 x 6.7 x 17.5/
275 x 170 x 444
14.2 x 8.6 x 18.6/
361 x 217 x 472
14.2 x 8.6 x 18.6/
361 x 271 x x 472
243 x 158 x 412
46.5/21.1
82/37.2
89/40.5
89/40.5
(2) L6-15R,
14.2 x 8.6 x 18.6/
(1) L6-20R, (1) L6-30R 361 x 217 x 472
89/40.5
5
230
50/60
IEC-C14
(4) IEC-C13
PW9120 1000i
1000/700
230
50/60
IEC-C14
(4) IEC-C13
PW9120 1500i
1500/1050
230
50/60
IEC-C14
(4) IEC-C13
PW9120 2000i
2000/1400
230
50/60
IEC-C14
PW9120 3000i
3000/2100
230
50/60
IEC-C20
(4) IEC-C13,
(1) IEC-C19
(4) IEC-C13,
(1) IEC-C19
Optional Extended Battery Modules (EBMs)
PW9120 BATT 700
–
–
–
PW9120 BATT 1000
–
–
–
PW9120 BATT 1500
–
–
–
PW9120 BATT 2000
–
–
–
PW9120 BATT 3000
–
–
–
Standard
Connector
Standard
Connector
Standard
Connector
Standard
Connector
Standard
Connector
–
–
–
–
–
9.6 x 6.2 x 16.2/
243 x 158 x 412
9.6 x 6.2 x 16.2/
243 x 158 x 412
10.8 x 6.7 x 17.5/
275 x 170 x 444
14.2 x 8.6 x 18.6/
361 x 217 x 472
14.2 x 8.6 x 18.6/
361 x 217 x 472
9.6 x 6.2 x 16.2/
243 x 158 x 412
9.6 x 6.2 x 16.2/
243 x 158 x 412
10.8 x 6.7 x 17.5/
275 x 170 x 444
14.2 x 8.6 x 18.6/
361 x 217 x 472
14.2 x 8.6 x 18.6/
361 x 217 x 472
1. Also user-selectable for 100, 110 and 127 Vac. 2. Automatic frequency selection. 3. 120V models have 6-ft attached line cord. 230V models have 6-ft detachable line cord.
4. Divided into 2 load segments (receptacle groups). 5. Also user-selectable for 220 and 240 Vac.
Available Options
Order Number
IPK-0329
1014018
Description
ConnectUPS-BD SNMP/WEB Card
AS/400 Relay Card
Powerware
WORLDWIDE HEADQUARTERS
8609 Six Forks Road
Raleigh, NC 27615 U.S.A.
Toll Free: 1.800.356.5794
or 919.872.3020
www.powerware.com
CANADA
Ontario: 416.798.0112
Revision 08/03
Reprint 08/03
29/13.2
361 x 271 x x 472
700/490
9120FXA
Weight
(LB/KG)
EUROPE/MIDDLE EAST/AFRICA
Denmark: 45.3677.7910
Finland: 358.9.452.661
France: 33.1.60.12.74.00
Germany: 49.7841.6660
Italy: 39.02.66.04.05.40
Norway: 47.23.03.65.50
Sweden: 46.8.598.940.00
United Kingdom: 44.1753.608.700
ASIA PACIFIC
Australia/NZ: 612.9878.5000
China: 86.21.6350.0606
HK/Korea/Taiwan: 852.2745.6682
India: 91.11.2649.9414 to 18
Singapore/SEA: 65.6829.8888
LATIN AMERICA
Argentina: 5411.4343.6323
Brazil: 55.11.3616.8500
México: 5255.9171.7777
28/12.6
34/15.3
44/19.8
81.6/37
85/38.5
31/14
44/20
57/26
110/50
110/50
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF