PQ series


Add to my manuals
38 Pages

advertisement

PQ series | Manualzz

Features

General

Enjoy the "Comfort" series by "COOLINE Air Conditioners"

The "Comfort" series of Packaged units (PQ) is another perfect illustration of how "COOLINE Air Conditioners" can simplify the air conditioning business for Clients, Consultants and Contractors. It is a clear statement for all that your life will be more "Comfortable" when you use the (PQ) series.

Some of the Salient Features

Quality/Reliability:

Using proven reliable components, the (PQ) "Comfort" series is designed, assembled and produced to meet the highest quality standards. It will operate to the satisfaction of the End User years after years. That translates into peace of mind and sustained "Comfort".

Simple Selection/Design Integration:

The (PQ) series is conceived to be easily fitted into the system design. Its compact dimensions and optimized air flow performance will provide the designer with an added "Comfort" in the process of selecting and integrating the units in the overall design.

Simple Installation/Maintenance:

Connect the Power cables and the Control wiring (all located in one area), connect ducting using the built-in duct flanges, arrange for proper drainage, reach in for any part/component through wide ample service/access doors...Installation and Maintenance cannot be more

"Comfortable".

Ease of Operation:

Let the digital "Performex-1 TM " controller do all the thinking! Just set the desired temperature level and the "Performex-1

TM

" controller will take care of all the operating functions while monitoring any abnormal signal to prevent/protect the unit and its components from any damage...and ensuring the complete

"Comfort" for the occupants.

And on top of that, the (PQ) "Comfort" series comes with a host of useful features such as the different types of corrosion protection solutions for the coils, Fresh Air Damper and UV Flow

TM

for added

IAQ and "Comfort".

2

CONTENTS

Page

Features ................................................................................................................................................... 2

Model decoding ........................................................................................................................................ 4

Blower drive options ................................................................................................................................. 4

Standard specifications/options/accessories ......................................................................................... 5-7

General data .......................................................................................................................................... 8-9

Selection procedure ............................................................................................................................... 10

Cooling capacities ............................................................................................................................. 11-15

Electrical data .................................................................................................................................... 16-17

Fan performance data ....................................................................................................................... 18-22

Sound level data ................................................................................................................................ 23-28

Pressure drop/blower motor efficiency ................................................................................................... 29

Unit dimensions ................................................................................................................................. 30-32

Controls and sequence of operation .................................................................................................. 33-34

Typical schematic wiring diagram ...................................................................................................... 35-36

CONTINUING RESEARCH RESULTS IN STEADY IMPROVEMENTS.

THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.

3

MODEL DECODING

MODELS: PQ036 - PQ060 (DIRECT DRIVE MOTOR)

1& 2

BASIC

PQ

COOLINE

PACKAGED

UNIT

3, 4 & 5

NOMINAL

COOLING

CAPACITY

(MBH)

036

048

060

6

ELECTRICAL

SUPPLY

( V-Ph-Hz )

L

: 380/415-3-50

(4 WIRE)

7

BLOWER

MOTOR

Y

:1 HP ODP

(DIRECT DRIVE)

8

DRIVE

OPTIONS

W

: 0.75 HP ODP

(DIRECT DRIVE)

N

: DIRECT

DRIVE

9

HEATER OPTIONS

(kW/STAGE)

10

EVAPORATOR

COIL

11

CONDENSER

COIL

N

: NO HEATER

A

: 5/1

C

: 7.5 /1

D

: 10 /2

*

12

ACCESSORIES

J

:ALUMINUM

FIN

J

:ALUMINUM

FIN

K

: COATED

ALUMINUM FIN

K

: COATED

ALUMINUM FIN

L

:COPPER FIN

L

:COPPER FIN

N

: STANDARD UNIT

NOTE

:

*

– Applicable for PQ060 models only.

MODELS: PQ075 - PQ360 (BELT DRIVEN MOTOR)

1& 2

BASIC

PQ

COOLINE

PACKAGED

UNIT

3, 4 & 5

NOMINAL

COOLING

CAPACITY

(MBH)

075

6

ELECTRICAL

SUPPLY

( V-Ph-Hz )

L

: 380/415-3-50

(4 WIRE)

7

BLOWER

MOTOR

8

DRIVE

OPTIONS

090

100

R

: 1.5 HP ODP

Z

: 2 HP ODP

J

: ALT. I

K

: ALT. II

Z

: 2 HP ODP

E

: 3 HP ODP

120 E

: 3 HP ODP

150

E

: 3 HP ODP

G

: 5 HP ODP

180

210

240

300

360

G

: 5 HP ODP

J

: 7.5 HP ODP

J

: 7.5 HP ODP

J

: 7.5 HP ODP

L

: 10 HP ODP

L

: 10 HP ODP

M

: 15 HP ODP

9

HEATER OPTIONS

(kW/STAGE)

10

EVAPORATOR

COIL

11

CONDENSER

COIL

N

: NO HEATER

C

: 7.5 /1

D

: 10 /2

E

: 12/2

N

: NO HEATER

D

: 10 /2

E

: 12/2

F

: 15 /2

J

L

:ALUMINUM

FIN

:COPPER FIN

J

L

: ALUMINUM

FIN

K

: COATED

ALUMINUM FIN

K

: COATED

ALUMINUM FIN

: COPPER FIN

12

ACCESSORIES

N

: STANDARD UNIT

C

: STD. UNIT WITH

FRESH AIR HOOD &

MANUAL DAMPER

P

: STD. UNIT WITH

PDS

M

:STD. UNIT WITH

PDS, FRESH AIR

HOOD & MANUAL

DAMPER

N

: NO HEATER

E

: 12/2

F

: 15 /2

G

: 20 /2

N

: NO HEATER

F

: 15 /2

G

: 20 /2

H

: 25/2

N

: NO HEATER

G

: 20 /2

H

: 25/2

J

: 30/2

BLOWER DRIVE OPTIONS

MODEL

NUMBER

PQ075

PQ090

PQ100

PQ120

PQ150

PQ180

PQ210

PQ240

PQ300

PQ360

OPTION

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

ALT. I

ALT. II

HP

1.5

2

2

3

2

3

3

3

5

5

7.5

5

7.5

7.5

7.5/10

10

15

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

1450

MOTOR

RPM

PULLEY

PITCH DIA.

(INCH)

2.7 - 3.7

2.7 - 3.7

2.7 - 3.7

3.1 - 4.1

2.7 - 3.7

3.1 - 4.1

3.1 - 4.1

3.1 - 4.1

3.7 - 4.7

4.8 - 6.0

3.7 - 4.7

4.3 - 5.5

3.7 - 4.7

4.3 - 5.5

4.3 - 5.5

4.3 - 5.5

4.3 - 5.5

4.3 - 5.5

4.3 - 5.5

5.5 - 6.9

BLOWER

SPEED RANGE (RPM)

MINIMUM

851

955

851

1096

699

977

737

881

813

941

725

891

766

891

663

843

725

843

692

848

MAXIMUM

1166

1309

1166

1450

958

1292

975

1166

1033

1176

921

1139

974

1139

848

1078

927

1078

886

1064

PULLEY

PITCH DIA.

(INCH)

4.6

4.1

4.6

4.1

5.6

4.6

6.1

5.1

6.6

7.4

7.4

7.0

7.0

7.0

9.4

7.4

8.6

7.4

9.0

9.4

APPROX. SPEED

CHANGE PER

PULLEY TURN

(RPM)

43

53

40

57

53

59

53

59

37

47

33

40

35

41

31

39

34

39

32

36

4

STANDARD SPECIFICATIONS

A. General

Packaged cooling or combination heating and cooling units suitable for mounting on the roof or ground. The packaged unit consists of reciprocating compressors, cooling coil, condenser coil, control wiring and interconnecting piping - all factory assembled and mounted on heavy gauge G-90 galvanized steel sheet press formed base, ready for field connection to utilities and ducts. The packaged unit is of rigid construction with holes provided in the base rails for overhead rigging. The unit is provided with an integral weather resistant control panel.

These units are rated and tested in accordance with ARI standard 210/ ARI 360.

B. Unit Enclosure

Panels are of heavy gauge, G-90 galvanized steel sheet with removable access panels, completely weatherized for outdoor installation and properly reinforced and brazed. Panels and access doors are provided for inspection and access for all internal parts. Enclosures are provided with adequately reinforced points of support for setting the unit. Steel sheet panels are zinc-coated and galvanized by the hot dip process of lock forming quality conforming to ASTM A 653 commercial weight G-90, followed by baked on electrostatic polyester dry powder coat paint, on all external panels.

C. Compressor

Compressors are hermetic reciprocating for PQ036 - PQ060 & PQ090 - PQ100 and hermetic scroll for all other models.

They are provided with all the standard controls and accessories necessary for safe operation. These are equipped with internal motor protector, factory installed crank case heater and rubber vibration isolator for quiet and efficient operation.

D. Air Cooled Condensing Section

1. The air-cooled condensing section is enclosed within the unit housing and consists of condenser coil, fan(s), electric motor(s) and inherently protected compressor(s). Inner grooved copper tubes with wall thickness of 0.0175 inches

(0.445 mm), mechanically bonded to enhanced louvered aluminum fins are standard for all condenser coils. Return bends have 0.022 inch thickness (0.56 mm). As an option, corrugated copper fins or enhanced coated alumi-

num fins may be provided.

Tube support sheets are galvanized steel, formed to provide structural strength.

2. Fans are propeller type, direct driven, upward discharge and provided with fan grille mounted on the casing.

3. Motors are totally enclosed air-over type with class F insulation. Inherent thermal protection is automatic reset type.

E. Evaporator Coil Section

1. All cooling coils are of enhanced louvered fins and inner grooved copper tubes with wall thickness of 0.0175 inches

(0.445mm), mechanically bonded to aluminum fins . Return bend has 0.022 inch thickness (0.56 mm). As option,

enhanced coated aluminum fins or corrugated copper fins may be provided

. Tube support sheets are galvanized steel, formed to provide structural strength.

2. Drain Pan: An insulated drain Pan made of G-90 galvanized steel is provided, for additional corrosion protection, mastic coated lining is provided as the surface.

3. Insulation: Insulation is supplied in adequate density and thickness for all units to prevent condensation from forming on the unit casing. Insulation meets the requirements of NFPA 90A and is protected against deterioration and erosion from air currents.

F. Evaporator Fan

PQ036 - PQ060:

Evaporator fan is of a centrifugal forward-curved blade design and sized to meet system airflow/pressure using direct drive motors. These fans are statically / dynamically balanced in the fan housing during final assembly. Fan motors have ball bearings and conform to NEMA MG-1 & MG-2. Motor starters are magnetic contactor, across-the-line type.

PQ075 - PQ360:

Evaporator fan is of centrifugal forward-curved blade design capable of handling total required CFM and static pressure in the low and the medium ranges. Casings are made of galvanized steel. Blower motors are of the open drip proof type (totally enclosed types are optional) and conform to NEMA MG-1 and MG-2. Fan drive is through adjustable pitch pulleys and belt driven. Blower motor is mounted on adjustable base and secured by locking device. Fan wheels shafts and bearing are selected to operate at 25% below first critical speed. Pillow block bearings are selected for at 200,000 hours average life at design operating conditions. Shaft is turned, ground and polished from solid steel. Fans and pulleys are keyed to shaft and designed for continuous operation at maximum motor horse power and fan speed. All rotating components and assemblies are statically and dynamically balanced and every unit is vibration tested before shipment from the factory.

5

G. Performex-1

TM

Controller Electronic Control Board

The COOLINE "Comfort" series Packaged units are provided with technologically advanced new Performex-1

TM Controller

Microprocessor Based Electronic Control Board, incorporating the following benefits and features:

- COMPLETE UNIT CONTROL:

Provides complete unit control for heating and cooling application whether single stage or two stage utilizing the input from sensor that measure temperatures during unit operation.

- COMPRESSOR LOCKOUT:

If any of the unit’s safety controls trip due to abnormal conditions the Electronic Control locks out the compressor, preventing restart, unless attended by qualified service technicians. The unit can be restarted only by reset the thermostat after ensuring safe system conditions.

- LEAD LAG OPERATION:

The unit electronic controls automatically alternate lead and lag the compressors for even operation. Compressor #1 can be set always lead as an option.

- ANTI-RECYCLE TIMER:

For compressor safety in case of accidental manual reset or immediate recycling of thermostat due to load demand. This considerably improves compressor life.

- PUMP DOWN OPTION:

In units equipped with pump down system the time delay creates the required time gap between the solenoid opening and compressor start to equalize the pressure in the system prior to compressor start up.

- AUTO/MANUAL RESET OF THE ALARM SIGNALS.

- FULL CONTROL OF THE INDOOR FAN:

Fan operation can be selected either to run continuously or stage with the compressor/heaters.

H. Electronic Thermostats

General information:

A dedicated electronic thermostat is supplied with the unit controls as standard. This thermostat controls one or two stage heating and cooling applications. The thermostat normally displays room temperature and mode of operation.

The temperature can be set by up/down buttons for both cooling and heating cycles. The thermostat also allows you to select continuous fan operation, or have the fan on intermittent operation with the equipment. It also displays the status of the unit, thus providing maximum information for the end user. As this is a dedicated thermostat supplied with the unit controller, the said controls can not be connected to any other BMS or DDC controller.

Special controller to be used, if required, for BMS or DDC controller connections.

OPTIONS AND ACCESSORIES

A. Electric Heaters

Electric heaters are of the resistance open coil type and conform to the requirements of UL 573 or equivalent. Electrical characteristics, kW capacities and number of stages are as indicated. Airflow switches, fusible links and overheat limit thermostats are provided to shut-off power in case of airflow failure/overheat. Electric heater kit is installed as an externally mounted kit at the supply opening.

B. UV Flow

TM

Light Emitters:

The damp & dark environment inside the unit could contribute for the growth and development of hazardous bacteria and fungi.

The UV flow

TM

concept uses emitter of Ultra Violet to simulate the effect of healthy sun radiation. This will inhibit the growth of these microorganism reducing in this manner mold related allergies and diseases. Breath safely with UV flow

TM

.

To order UV flow

TM

use the kit number in tables below:

MODEL No. PQ036/048/060

KIT PART No.

700-391-30

PQ075

700-391-23

PQ090

700-391-24

PQ100

700-391-25

PQ120/150 PQ180/210

700-391-26 700-391-27

PQ240/300

700-391-28

PQ360

700-391-31

C. Economizer

This can be provided as an option to be ordered separately if required for horizontal discharge units only. Economizer utilizes cool outside air to satisfy cooling load to minimize energy consumption by maintaining poise between outside air intake and compressor operation when required as per load demand.

The Economizer is operative either by a dry bulb Outdoor Air Thermostat (OAT) or a Solid State Enthalpy Controller (EC) to sense the outdoor air temperature. The unit is equipped with an electronic control board, the PsychroTroll™ with a sensitive feedback system carefully modulating the damper to allow correct percentage of fresh air and return air. The

PsychroTroll™

is designed to match with a separate COOLINE electronic controller & thermostat.

6

STANDARD FEATURES/OPTIONS/ACCESSORIES

DESCRIPTION

Horizontal discharge

Compressor crankcase heaters

Evaporator fan–belt driven

(1)

Evaporator fan motor – ODP type (TEFC type optional)

(2)

Condenser fan – direct drive, propeller type

Condenser fan motor – totally enclosed air-over type

Electric heaters

Filter drier

Filter, synthetic media

Filter, aluminum

Compressor overload protection

Low pressure switch

High pressure switch

Cooling & heating thermostat

Condenser fan guard

Condenser coil guard

Manual outside air damper

(3)

Economizer

Enthalpy sensor

NOTES:

(1) Direct drive motors for PQ036 to PQ060.

(2) TEFC motors are available for PQ075 to PQ360.

(3) Manual outside air damper is available for PQ075 to PQ360.

STANDARD

FEATURES

OPTION

(FACTORY

INSTALLED)

ACCESSORY

(FIELD

INSTALLED)

7

GENERAL DATA

(DIRECT DRIVE MOTOR)

MODEL NUMBER

NOMINAL CAPACITY, TONS (kW)

COMPRESSOR Quantity

Oil (oz)

Refrigerant

CONDENSER FAN

Operating Charge (oz)

Type/Drive

Quantity – Diameter (inch)

Nominal CFM (L/S)

CONDENSER COIL

EVAPORATOR BLOWER

Motor HP – RPM

Type

Tube dia. - Rows - Fins per inch

Total face area, Sq. ft. (Sq. m.)

Type

Size (inch)

Drive type

Nominal CFM (L/S)

EVAPORATOR COIL

LOW PRESSURE

SWITCH

RETURN AIR FILTERS

SHIPPING WEIGHT

Motor HP (Standard)

Type

Tube dia. - Rows - Fins per inch

Total face area, Sq. ft. (Sq. m.)

Open

Close

Quantity

Size (inch)

Kgs.

PQ036 PQ048 PQ060

3 (10.5)

1

40

4 (14)

1

70

R-22

5 (17.6)

1

70

83

1 – 24

3200 (1510)

155

Propeller/Direct

1 – 24

3000 (1415)

208

1 – 24

3000 (1415)

1/3 – 1075 1/3 – 1075 1/3 – 1075

Inner Grooved Tubes and Enhanced Fins

3/8-1-16

10.8 (1)

3/8-2-16

10.8 (1)

Centrifugal

10 x 8

3/8-2-16

10.8 (1)

10 x 8 10 x 8

1200 (566)

0.75

Direct Drive

1600 (755)

0.75

Inner Grooved Tubes and Enhanced Fins

1800 (850)

1

3/8-3-14

4.5 (0.42)

3/8-3-14

5.4 (0.5)

25 ± 5 PSIG

50 ± 5 PSIG

3/8-3-14

5.4 (0.5)

2

16 x 25

197

2

16 x 25

213

2

16 x 25

215

8

GENERAL DATA

MODEL NUMBER PQ075 PQ090 PQ100 PQ120 PQ150 PQ180 PQ210 PQ240 PQ300 PQ360

NOMINAL CAPACITY, TONS (kW)

COMPRESSOR Quantity

Oil (oz)

Refrigerant

Operating Charge (oz)

CONDENSER FAN Type/Drive

Qty. – Diameter (inch)

Nominal CFM (L/S)

6 (21) 7.5 (26.4) 8.5 (30) 10 (35) 12 (42) 15 (53) 17.5 (62) 20 (70.4) 25 (88) 30 (105)

1 2 2 2 2 2 2 2 2 2

60 45 x 2 70 x 2 60 x 2 60 x 2 81 & 110 110 x 2 110 x 2 140 x 2 140 x 2

R-22

178 119 x 2 130 x 2 131 x 2 148 x 2 190 & 201 256 x 2 271 x 2 369 x 2 462 x 2

Propeller/Direct

1 – 26

4800(2265) 5500(2595) 6000 (2830)

2 – 26 2 – 30

11000(5190) 10500(4950)15000(7080) 14300(6750) 14700(6938)

Motor HP – RPM

CONDENSER COIL Type

1/3 – 850

Tube dia. - Rows - Fins per inch 3/8-2-16

Total face area, Sq. ft. (Sq. m.) 14 (1.3) 16 (1.5)

3/4 – 950 1.5 – 950

Inner Grooved Tubes and Enhanced Fins

20 (1.86)

3/8-3-16 3/8-2-14 3/8-3-14 3/8-2-14 3/8-3-14 3/8-3-14

30 (2.78) 38 (3.53) 48 (4)

EVAPORATOR

BLOWER

Type

Size (inch)

Drive type

Nominal CFM (L/S)

12 x 12

Centrifugal

15 x 15

Belt

18 x 18 20 x 18

2400(1135) 3000(1415) 3400(1605) 4000(1890) 4800(2265) 6000(2830) 7000(3300) 7500(3540) 9600(4530) 11250(5309)

LOW PRESSURE

SWITCH

Motor HP - Std. / Alt

Motor Frame (NEMA) Std. / Alt.

1.5/2 2/3 2/3 3 3/5 5/7.5

5/7.5

7.5

7.5/10 10/15

56 / 56 56/184T 184T/213T 213T/215T

215T/254T

Fan RPM range

Factory setting full turns open

Fan pulley pitch dia.

EVAPORATOR COIL Type

Tube dia. - Rows - Fins per inch

850-1310 850-1450 700-1290 735-1165 815-1175 725-1140 765-1140 665-1080 725-1080 692-1064

3

4.6

3

4.6

3

5.6

3

6.1

3

6.6

3

7.4

3

7

Inner Grooved Tubes and Enhanced Fins

3/8-3-14 3/8-2-14

3

9.4

3/8-3-14

3

8.6

3

9

3/8-4-14

Total face area, Sq. ft. (Sq. m.) 6 (0.56) 9 (0.84) 10 (0.93) 11 (1.02) 12.5 (1.16) 19.5 (1.81) 19.5 (1.81) 22 (2.04) 27 (2.5) 27 (2.5)

Open

Close

25 ± 5 PSIG

50 ± 5 PSIG

RETURN AIR

FILTERS

Qty.

Size (inch)

SHIPPING WEIGHT Kgs.

16-1/2 x 18-3/8

337 366

4

441

18 x 24

445 450

6 8

18 x 18 (1)

18 x 24 (3)

24 x 24 (2)

12 x 24 (2)

24 x 24 (6)

800 840 975 1025 1323

9

SELECTION PROCEDURE

1. Determine cooling and heating capacity requirements at design conditions

Data

:

Condenser entering air temperature

Evaporator entering air temperature

Evaporator airflow

Required cooling capacity

Sensible heat capacity

Required heating capacity

External static pressure

Power supply (V-Ph-Hz)

: 95

0

F

: 80

0

F DB / 67

0

F WB

: 7500 CFM

: 235,000 BTUH

: 160,000 BTUH

: 20 kW

: 1.23 INCH WG.

: 380/415-3-50

2. Unit selection based on required cooling capacity

Enter cooling capacity performance data at condenser entering air temp. at 95

0

F and evaporator entering air temp. 80

0

F

DB, 67

0

F WB, 7500 CFM airflow. The PQ240 unit will give 245,800 BTUH cooling capacity (gross) and 179,200 BTUH sensible heat capacity (gross).

3. Electric heater selection

Heating capacity required =20 kW.

Enter electric heating table for PQ240 at 380/415-3-50 power supply.

20 kW heater at 380/415 volts satisfies the required heating.

4. Determine fan speed and power requirements at design conditions

Before entering the fan performance tables, calculate the summation of external static pressure for the required components as follows.

External static pressure

Electric heater

: 1.23 INCH WG.

: 0.17 INCH WG.

1.4 INCH WG.

Enter fan performance table for PQ240 model. For 7500 CFM and external static pressure of 1.4 INCH WG, it require 911 RPM and 4.45 brake horse power (BHP) wherein the standard motor will meet job requirements.

5. Determine input power to motor

Use fan motor efficiency table.

Blower motor watts = BHP x 746 watts = 4.45 x 746 = 4098 watts.

Motor efficiency 0.81

6. Determine net capacities

Above capacities are gross and do not include blower motor heat gain.

Determine net capacities as follows:

Net cooling capacity = Gross cooling capacity – blower motor heat

= 245,800 – (4098 WATTS x 3.413 BTUH/WATTS) = 231,813 BTUH

Net sensible capacity = 179,200 – (4098 WATTS x 3.413 BTUH/WATTS) = 165,213 BTUH

7. Altitude correction factors for cooling capacity

ALTITUDE, FT.

Total capacity

FACTOR

Sensible capacity

2000 4000 6000 8000 10000

0.98

0.93

0.96

0.86

0.93

0.80

0.90

0.75

0.88

0.70

10

COOLING CAPACITIES

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

29.66

28.04

3.85

27.30

25.68

4.01

26.08

24.35

4.19

62

33.68

31.69

3.49

31.72

30.75

3.65

1125/0.104

32.53

24.13

4.03

30.04

23.12

4.21

28.68

22.46

4.41

67

36.77

26.21

3.64

34.73

25.57

3.81

35.59

18.74

4.23

32.93

17.79

4.44

31.52

17.22

4.67

72

40.10

20.65

3.79

37.97

20.02

3.99

Model No.: PQ036

EVAPORATOR AIRFLOW, CFM/DR

1225/0.111

EVAPORATOR ENTERING AIR, WBE (

0

F)

30.16

28.51

3.93

27.76

26.11

4.09

26.47

24.73

4.27

62

34.27

33.05

3.58

32.24

31.26

3.73

33.09

25.32

4.11

30.54

24.29

4.30

29.21

23.67

4.50

67

37.39

27.42

3.72

35.32

26.79

3.89

36.22

19.52

4.32

33.53

18.57

4.53

32.10

18.00

4.76

72

40.82

21.44

3.87

38.65

20.83

4.08

30.7

29.0

4.1

28.3

26.6

4.2

26.9

25.2

4.4

62

34.9

33.7

3.7

32.8

31.8

3.8

1350/0.119

33.7

26.8

4.2

31.1

25.7

4.4

29.7

25.1

4.6

67

38.1

28.9

3.8

35.9

28.3

4.0

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

38.94

5.56

37.50

36.75

5.75

35.06

34.35

5.89

62

44.61

40.93

5.32

42.39

39.83

5.36

40.00

1275/0.099

32.40

5.85

41.18

31.43

6.07

38.53

30.38

6.22

67

48.75

34.30

5.55

46.43

33.28

5.62

43.89

25.76

6.15

45.17

24.80

6.39

42.37

23.81

6.58

72

53.20

27.57

5.77

50.78

26.63

5.88

48.09

Model No.: PQ048

EVAPORATOR AIRFLOW, CFM/DR

1450/0.108

EVAPORATOR ENTERING AIR, WBE (

0

F)

40.3

5.7

38.5

37.7

5.9

36.0

35.3

6.0

62

45.9

44.1

5.5

43.6

43.0

5.5

41.1

34.7

6.0

42.4

33.8

6.2

39.7

32.7

6.4

67

50.2

36.7

5.7

47.8

35.7

5.8

45.1

27.3

6.3

46.5

26.3

6.6

43.6

25.3

6.8

72

54.9

29.2

5.9

52.3

28.2

6.0

49.5

41.3

5.9

39.5

38.7

6.1

36.9

36.1

6.2

62

47.1

46.2

5.6

44.7

43.8

5.7

42.1

1650/0.119

37.3

6.2

43.4

36.3

6.4

40.6

35.2

6.6

67

51.6

39.2

5.9

49.1

38.2

5.9

46.4

CONDENSER

ENTERING AIR

TEMP. (

0

F)

1600/0.117

29.6

7.8

53.7

27.2

7.9

50.3

26.1

8.2

72

65.5

31.7

7.0

62.3

30.7

7.4

59.2

Model No.: PQ060

EVAPORATOR AIRFLOW, CFM/DR

1800/0.128

EVAPORATOR ENTERING AIR, WBE (

0

F)

47.9

7.3

45.3

42.4

7.3

42.4

39.7

7.6

62

55.8

50.1

6.7

52.9

48.9

7.0

50.2

39.6

7.6

49.9

36.9

7.7

46.7

35.8

8.0

67

61.3

41.7

6.9

58.1

40.6

7.3

55.3

31.2

8.0

54.9

28.7

8.1

51.4

27.6

8.5

72

67.1

33.2

7.2

63.8

32.2

7.7

60.7

2000/0.139

85

95

105

115

125

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

62

54.6

47.0

6.4

51.7

45.8

6.8

49.1

44.7

7.0

44.3

41.5

7.1

41.5

38.8

7.4

67

59.8

39.4

6.7

56.7

38.3

7.1

54.0

37.2

7.4

48.8

34.6

7.5

45.7

33.5

7.8

62

57.0

53.2

6.8

53.9

51.4

7.2

51.2

48.8

7.4

46.2

43.2

7.5

43.1

40.4

7.8

67

62.5

44.0

7.1

59.2

42.8

7.5

56.3

41.8

7.8

50.9

39.1

7.9

47.6

37.9

8.2

TC – Total Capacity (1000 Btuh) Gross

SC – Sensible Heat Capacity (1000 Btuh) G kW – Total unit power input

DR – Wet Bulb depression ratio

DBE – Dry Bulb Temp. (

0

F) of Air Entering Coil

WBE – Wet Bulb Temp. (

0

F) of Air Entering Coil

DBL – Dry Bulb Temp. ( 0 F) of Air Leaving Coil

WBL – Wet Bulb Temp. (

0

F) of Air Leaving Coil

NOTES:

1. Direct interpolation is permissible – Do not extrapolate.

2. Capacities above are based on DBE = 80 0 F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 – DR) (DBE – 80).

3. To calculate leaving conditions, follow this procedure: DBL = DBE – (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL – [DR (DBE – WBE)].

4. Total unit power input at 0.15 ESP for PQ036/PQ048 & 0.2 ESP for PQ060.

32.6

8.2

56.0

30.1

8.3

52.5

29.0

8.7

72

68.5

34.7

7.4

65.1

33.6

7.9

61.9

29.0

6.5

47.7

28.0

6.8

44.7

27.0

7.0

72

56.4

30.8

6.1

53.8

29.8

6.2

50.9

11

37.0

20.5

4.4

34.2

19.5

4.7

32.7

18.9

4.9

72

41.6

22.4

4.0

39.3

21.8

4.2

COOLING CAPACITIES

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

60.35

55.20

8.17

57.29

54.00

8.72

53.98

52.66

9.34

62

67.31

58.40

7.18

64.41

57.18

7.66

70.1

67.1

9.6

66.3

64.6

10.3

62.3

60.8

11.0

62

81.3

73.4

8.6

77.7

71.9

9.1

1900/0.11

66.06

45.94

8.64

62.77

44.76

9.24

59.22

43.51

9.91

67

73.56

49.06

7.57

70.51

47.90

8.08

2400/0.108

77.6

55.8

10.2

73.7

54.5

10.8

69.4

52.9

11.6

67

89.5

61.6

9.0

85.9

60.3

9.5

85.9

44.4

10.7

81.6

43.0

11.5

77.0

41.5

12.4

72

98.6

49.8

9.5

94.9

48.5

10.1

72.31

36.60

9.16

68.71

35.42

9.82

64.86

34.17

10.54

72

80.26

39.55

7.98

77.06

38.45

8.55

Model No.: PQ075

EVAPORATOR AIRFLOW, CFM/DR

2400/0.131

EVAPORATOR ENTERING AIR, WBE (

0

F)

63.06

61.26

8.56

59.82

58.21

9.13

56.37

54.99

9.75

62

70.59

66.54

7.56

67.45

65.28

8.04

69.19

51.89

9.04

65.65

50.68

9.66

61.91

49.43

10.34

67

77.20

55.09

7.96

73.98

53.95

8.48

75.93

40.53

9.60

72.10

39.33

10.28

68.07

38.10

11.03

72

84.41

43.54

8.39

81.00

42.42

8.97

Model No.: PQ090

EVAPORATOR AIRFLOW, CFM/DR

3000/0.128

EVAPORATOR ENTERING AIR, WBE (

0

F)

73.5

71.3

10.1

69.4

67.6

10.8

65.2

63.6

11.5

62

85.2

83.4

9.1

81.6

80.9

9.6

81.6

63.2

10.7

77.3

61.7

11.4

72.8

60.2

12.2

67

94.2

69.2

9.5

90.3

67.8

10.1

90.4

49.2

11.3

85.9

47.9

12.1

81.1

46.4

13.0

72

103.8

54.8

10.0

100.0

53.5

10.6

65.08

63.22

9.02

61.66

60.01

9.60

58.00

56.59

10.23

62

72.91

71.04

8.02

69.63

67.93

8.50

75.9

73.7

10.8

71.7

69.8

11.4

67.5

65.7

12.2

62

88.2

87.3

9.7

84.2

83.5

10.2

2900/0.153

71.54

57.47

9.52

67.76

56.19

10.15

63.87

54.94

10.84

67

79.83

60.67

8.42

76.44

59.51

8.95

3600/0.148

84.4

70.0

11.3

79.9

68.5

12.1

75.2

66.9

12.9

67

97.5

76.2

10.1

93.5

74.7

10.7

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

80.9

10.6

79.8

78.9

10.9

74.5

73.0

11.2

62

94.8

84.9

9.7

90.0

82.8

10.1

84.9

kW

TC – Total Capacity (1000 Btuh) Gross

SC – Sensible Heat Capacity (1000 Btuh) Gross

2700/0.109

67.5

11.2

87.7

65.4

11.6

81.8

63.2

11.9

67

103.9

71.4

10.2

98.9

69.4

10.7

93.4

kW – Total unit power input

DR – Wet Bulb depression ratio

53.8

11.8

96.3

51.7

12.2

90.0

49.6

12.7

72

113.7

57.6

10.7

108.4

55.7

11.3

102.4

Model No.: PQ100

EVAPORATOR AIRFLOW, CFM/DR

3400/0.13

EVAPORATOR ENTERING AIR, WBE (

0

F)

87.4

11.0

83.6

81.9

11.3

77.9

76.4

11.7

62

99.7

96.7

10.1

94.7

92.8

10.6

89.2

76.3

11.6

92.1

74.2

12.0

85.9

72.0

12.4

67

109.5

80.3

10.6

104.1

78.2

11.1

98.2

59.7

12.2

101.4

57.6

12.7

94.7

55.4

13.2

72

120.0

63.6

11.1

114.3

61.6

11.7

108.0

DBE – Dry Bulb Temp. (

0

F) of Air Entering Coil

WBE – Wet Bulb Temp. (

0

F) of Air Entering Coil

90.3

11.6

86.3

84.6

11.9

80.4

78.8

12.3

62

103.3

101.2

10.7

97.9

95.9

11.1

92.2

4100/0.151

67

113.4

88.4

11.2

107.7

86.3

11.7

101.7

84.5

12.2

95.3

82.3

12.6

88.9

80.1

13.0

72

124.6

68.9

11.7

118.6

66.9

12.3

111.9

64.9

12.8

105.0

62.8

13.4

98.1

60.7

13.8

DBL – Dry Bulb Temp. (

0

F) of Air Leaving Coil

WBL – Wet Bulb Temp. ( 0 F) of Air Leaving Coil

NOTES:

1. Direct interpolation is permissible – Do not extrapolate.

2. Capacities above are based on DBE = 80

0

F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 – DR) (DBE – 80).

3. To calculate leaving conditions, follow this procedure: DBL = DBE – (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL – [DR (DBE – WBE)].

4. Total unit power input based on nominal CFM & 0.25 ESP.

78.50

44.08

10.12

74.50

42.86

10.81

70.25

41.60

11.58

72

87.38

47.13

8.88

83.75

45.98

9.48

93.7

53.6

12.0

89.1

52.3

12.8

84.0

50.7

13.7

72

107.7

59.3

10.6

103.7

58.1

11.3

12

COOLING CAPACITIES

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

99.4

94.1

13.0

94.0

91.7

13.6

88.7

88.0

14.2

62

109.7

98.5

11.8

104.9

96.1

12.4

123.0

113.2

16.0

112.9

110.8

17.1

106.1

104.0

18.4

62

132.0

118.3

14.0

125.8

115.7

15.0

3200/0.105

108.9

78.2

13.8

102.9

75.8

14.4

97.1

73.7

15.0

67

120.0

82.5

12.4

114.7

80.2

13.1

3800/0.119

134.8

94.5

16.9

123.7

91.8

18.1

116.5

89.2

19.5

67

144.3

99.3

14.8

137.9

96.9

15.8

Model No.: PQ150

147.6

75.6

17.9

135.6

72.7

19.3

127.6

70.0

20.7

72

157.7

80.0

15.6

150.9

77.7

16.7

119.2

62.0

14.6

112.8

59.8

15.3

106.5

57.7

16.0

72

131.0

66.2

13.1

125.5

64.1

13.9

Model No.: PQ120

EVAPORATOR AIRFLOW, CFM/DR

4000/0.124

EVAPORATOR ENTERING AIR, WBE (

0

F)

103.9

102.8

13.7

98.1

97.2

14.3

92.6

91.8

14.8

62

114.9

111.9

12.4

109.6

108.2

13.1

113.9

88.0

14.4

107.7

85.7

15.1

101.6

83.6

15.7

67

125.9

92.5

13.1

120.2

90.1

13.8

125.0

68.5

15.3

118.3

66.3

16.1

111.6

64.2

16.7

72

137.8

72.8

13.8

131.9

70.7

14.6

EVAPORATOR AIRFLOW, CFM/DR

4800/0.143

EVAPORATOR ENTERING AIR, WBE (

0

F)

128.4

127.6

17.0

117.8

115.4

18.1

110.6

108.4

19.4

62

137.8

134.3

14.9

131.4

128.7

15.9

140.9

106.3

17.9

129.2

103.8

19.2

121.5

101.2

20.6

67

151.1

111.3

15.7

144.2

108.8

16.8

154.6

83.3

19.0

141.7

80.4

20.4

133.5

77.8

21.9

72

165.3

87.8

16.6

158.1

85.5

17.7

107.1

106.0

14.4

101.0

100.0

15.0

95.2

94.4

15.6

62

118.6

117.2

13.2

112.9

111.5

13.8

132.2

131.3

18.2

121.1

118.6

19.3

113.7

111.5

20.6

62

142.0

139.2

16.1

135.2

132.5

17.1

4800/0.143

117.6

97.2

15.2

111.1

94.9

15.9

104.7

92.7

16.5

67

130.1

101.7

13.8

124.2

99.4

14.6

5800/0.167

145.1

117.0

19.1

133.0

114.7

20.4

125.0

112.0

21.8

67

155.9

122.2

16.9

148.6

119.7

18.0

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

132.5

19.2

138.0

126.6

20.2

129.1

123.1

21.3

62

162.7

142.6

17.4

156.0

138.1

18.4

146.6

kW

TC – Total Capacity (1000 Btuh) Gross

SC – Sensible Heat Capacity (1000 Btuh) Gross

4800/0.177

111.0

20.5

152.3

105.6

21.5

142.8

102.2

22.7

67

179.2

120.6

18.4

171.7

116.3

19.5

161.7

kW – Total unit power input

DR – Wet Bulb depression ratio

89.2

21.7

167.6

84.1

22.8

157.2

80.8

24.1

72

196.6

98.0

19.4

188.7

94.1

20.6

177.9

Model No.: PQ180

EVAPORATOR AIRFLOW, CFM/DR

6000/0.22

EVAPORATOR ENTERING AIR, WBE (

0

F)

148.0

20.6

144.3

139.5

21.6

134.9

130.7

22.6

62

170.5

158.5

18.7

163.1

153.7

19.7

153.5

122.6

21.8

159.5

116.9

22.9

149.3

113.4

24.0

67

187.8

132.5

19.7

180.0

128.1

20.8

169.3

96.9

23.0

175.6

91.6

24.2

164.7

88.3

25.5

72

206.1

105.9

20.7

197.8

101.9

21.9

186.5

DBE – Dry Bulb Temp. (

0

F) of Air Entering Coil

WBE – Wet Bulb Temp. (

0

F) of Air Entering Coil

155.9

22.1

148.7

143.8

23.1

139.0

134.6

24.2

62

176.0

171.8

20.2

168.5

166.9

21.2

158.4

7200/0.264

67

193.8

142.3

21.2

186.0

138.0

22.3

174.8

132.2

23.3

164.5

126.3

24.4

154.2

123.0

25.6

72

213.2

112.5

22.3

204.5

108.3

23.5

192.7

103.3

24.6

181.6

97.9

25.8

170.4

94.6

27.1

DBL – Dry Bulb Temp. (

0

F) of Air Leaving Coil

WBL – Wet Bulb Temp. ( 0 F) of Air Leaving Coil

NOTES:

1. Direct interpolation is permissible – Do not extrapolate.

2. Capacities above are based on DBE = 80

0

F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 – DR) (DBE – 80).

3. To calculate leaving conditions, follow this procedure: DBL = DBE – (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL – [DR (DBE – WBE)].

4. Total unit power input based on nominal CFM & 0.35 ESP.

129.3

74.5

16.2

122.3

72.3

16.9

115.2

70.1

17.6

72

142.6

78.8

14.6

136.3

76.6

15.4

159.5

90.3

20.3

146.3

87.5

21.7

137.8

85.0

23.2

72

171.0

95.0

17.8

163.3

92.6

19.0

13

COOLING CAPACITIES

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125 kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

169.3

161.9

24.5

157.2

152.6

25.4

146.8

142.7

26.2

62

190.8

171.8

22.7

181.0

167.5

23.6

200.5

184.1

27.2

188.5

179.4

28.7

175.7

174.2

30.2

62

223.5

194.0

24.4

212.0

189.4

25.8

5800/0.117

186.1

134.1

25.9

173.3

128.7

26.9

161.9

124.6

27.7

67

209.5

143.8

23.8

198.9

139.6

24.9

6000/0.095

220.8

154.4

28.6

207.8

149.7

30.3

193.8

144.4

31.9

67

245.3

163.9

25.5

233.1

159.4

27.1

Model No.: PQ240

242.8

124.1

30.2

228.9

119.5

32.0

213.6

114.2

33.9

72

268.7

133.2

26.7

256.0

129.0

28.5

204.8

106.2

27.4

190.8

101.0

28.5

178.5

97.0

29.5

72

229.5

115.3

25.0

218.5

111.4

26.2

Model No.: PQ210

EVAPORATOR AIRFLOW, CFM/DR

7000/0.136

EVAPORATOR ENTERING AIR, WBE (

0

F)

175.4

171.0

26.1

162.9

158.1

27.0

151.9

147.6

27.8

62

198.0

190.9

24.2

187.9

183.9

25.2

193.3

148.4

27.5

180.0

142.9

28.5

168.1

138.8

29.4

67

217.6

158.1

25.4

206.7

153.9

26.5

213.0

115.6

29.0

198.2

110.2

30.2

185.6

106.2

31.2

72

239.0

124.8

26.6

227.2

120.8

27.9

EVAPORATOR AIRFLOW, CFM/DR

7500/0.112

EVAPORATOR ENTERING AIR, WBE (

0

F)

210.8

209.2

28.4

198.0

197.2

29.9

184.3

183.9

31.5

62

235.6

220.5

25.5

223.2

215.8

27.0

232.8

174.1

29.9

218.8

169.3

31.6

203.9

163.9

33.3

67

258.8

183.7

26.7

245.8

179.2

28.3

256.7

137.4

31.6

241.5

132.5

33.5

225.7

127.4

35.5

72

284.5

146.7

28.0

270.9

142.4

29.8

180.1

175.6

27.7

167.2

162.4

28.5

155.8

151.4

29.4

62

203.7

199.3

25.7

192.9

188.8

26.7

218.0

216.4

29.9

204.7

203.8

31.4

190.2

189.7

33.0

62

243.9

241.3

26.9

231.0

229.3

28.4

8200/0.154

198.7

161.6

29.1

184.9

156.0

30.1

172.4

151.6

31.0

67

224.0

171.5

26.9

212.6

167.3

28.0

9000/0.128

241.1

192.2

31.4

226.7

187.5

33.2

211.1

182.1

34.9

67

268.8

202.2

28.1

255.2

197.7

29.8

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

234.8

32.4

224.8

220.3

34.4

207.8

203.6

36.5

62

267.0

245.6

28.5

254.1

240.3

30.4

240.2

kW

TC – Total Capacity (1000 Btuh) Gross

SC – Sensible Heat Capacity (1000 Btuh) Gross

8000/0.117

195.3

34.1

248.0

188.9

36.4

229.6

182.2

38.7

67

293.4

206.0

29.9

279.9

201.0

32.0

264.6

kW – Total unit power input

DR – Wet Bulb depression ratio

155.4

36.1

273.5

149.1

38.6

253.8

142.6

41.2

72

322.4

166.0

31.4

307.6

160.8

33.6

291.4

Model No.: PQ300

EVAPORATOR AIRFLOW, CFM/DR

9600/0.135

EVAPORATOR ENTERING AIR, WBE (

0

F)

243.5

34.0

232.2

227.5

36.1

214.6

210.3

38.2

62

276.5

271.9

30.1

263.1

257.9

32.0

248.5

214.9

35.8

256.8

208.4

38.1

237.6

201.6

40.5

67

304.7

225.8

31.5

290.1

220.5

33.6

274.3

168.2

37.9

283.9

161.9

40.4

263.2

155.3

43.1

72

334.8

178.7

33.0

319.5

173.7

35.4

302.5

DBE – Dry Bulb Temp. (

0

F) of Air Entering Coil

WBE – Wet Bulb Temp. (

0

F) of Air Entering Coil

249.7

36.0

238.2

233.4

38.1

219.6

215.2

40.2

62

284.0

278.4

32.0

269.9

264.5

33.9

254.8

11200/0.153

67

312.7

243.9

33.4

297.6

238.6

35.5

281.6

233.3

37.8

263.7

226.7

40.1

243.8

219.8

42.5

180.3

39.9

291.6

173.6

42.5

270.3

167.0

45.2

72

344.7

190.8

35.0

328.8

185.6

37.4

311.4

DBL – Dry Bulb Temp. (

0

F) of Air Leaving Coil

WBL – Wet Bulb Temp. ( 0 F) of Air Leaving Coil

NOTES:

1. Direct interpolation is permissible – Do not extrapolate.

2. Capacities above are based on DBE = 80

0

F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 – DR) (DBE – 80).

3. To calculate leaving conditions, follow this procedure: DBL = DBE – (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL – [DR (DBE – WBE)].

4. Total unit power input based on nominal CFM & 0.35 ESP.

219.1

124.1

30.7

203.9

118.7

31.9

190.9

114.6

32.9

72

246.4

133.5

28.2

234.0

129.4

29.5

266.5

149.3

33.3

251.0

144.6

35.2

233.9

139.1

37.2

72

296.0

158.9

29.5

281.3

154.3

31.4

14

COOLING CAPACITIES

CONDENSER

ENTERING AIR

TEMP. (

0

F)

85

95

105

115

125

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC kW

TC

SC

62

303.69

276.69

32.15

297.83

271.38

33.79

286.54

257.88

35.59

279.01

248.32

37.31

271.06

241.24

39.75

kW

TC – Total Capacity (1000 Btuh) Gross

SC – Sensible Heat Capacity (1000 Btuh) Gross

9600/0.066

67

330.03

228.32

32.6

323.79

223.56

34.28

311.72

214.33

36.12

303.82

209.22

37.88

295.49

206.39

40.37

kW – Total unit power input

DR – Wet Bulb depression ratio

72

357.93

179.12

33.2

351.72

175.20

34.93

338.90

167.26

36.83

330.62

162.85

38.64

321.52

159.99

41.21

Model No.: PQ360

EVAPORATOR AIRFLOW, CFM/DR

11250/0.078

EVAPORATOR ENTERING AIR, WBE (

0

F)

62

311.27

289.49

33.48

305.39

280.96

35.13

293.63

264.26

36.93

285.78

254.35

38.64

277.94

247.37

41.08

67

338.48

248.05

33.96

332.14

243.17

35.64

319.94

233.69

37.48

311.65

228.27

39.23

302.87

225.31

41.73

72

368.05

192.00

34.65

361.26

187.77

36.39

348.17

179.62

38.29

339.44

174.99

40.11

330.23

172.22

42.68

DBE – Dry Bulb Temp. (

0

F) of Air Entering Coil

WBE – Wet Bulb Temp. (

0

F) of Air Entering Coil

62

315.90

293.79

34.6

309.91

285.12

36.24

297.93

268.14

38.04

290.31

258.37

39.75

281.59

250.62

42.18

12500/0.088

67

344.11

262.89

35.08

337.61

257.83

36.77

325.14

248.00

38.61

316.47

242.26

40.36

307.80

239.51

42.85

72

373.92

201.19

35.85

367.46

197.11

37.59

353.99

188.70

39.5

344.83

183.82

41.31

335.67

181.19

43.9

DBL – Dry Bulb Temp. (

0

F) of Air Leaving Coil

WBL – Wet Bulb Temp. (

0

F) of Air Leaving Coil

NOTES:

1. Direct interpolation is permissible – Do not extrapolate.

2. Capacities above are based on DBE = 80

0

F. For higher or lower DBE, add following Correction Factor to Sensible Capacity = 1.08 x CFM (1 – DR) (DBE – 80).

3. To calculate leaving conditions, follow this procedure: DBL = DBE – (Sensible Capacity (Btuh) / 1.08 x CFM); WBL = DBL – [DR (DBE – WBE)].

4. Total unit power input based on nominal CFM & 0.55 ESP.

15

ELECTRICAL DATA

MODELS: PQ036 - PQ060

MODEL

NUMBER

PQ036

PQ048

PQ060

POWER

SUPPLY

(V-Ph-Hz)

VOLTAGE

RANGE

FM COMPRES-

SOR

BLOWER

MOTOR

ELECTRIC

HEATER

MCA MOCP

380/415-3-50

(4 WIRE)

380/415-3-50

(4 WIRE)

380/415-3-50

(4 WIRE)

MIN.

MAX.

FLA RLA LRA HP FLA kW FLA

342

342

342

457

457

457

2.3

2.3

2.3

5.9

10.4

9.6

42

55

65

0.75

0.75

1

5.5

5.5

7.8

5

– 15.2

7.6

16.4

7.5

11.4

21.1

10* 15.2

25.9

5

– 20.8

7.6

20.8

7.5

11.4

21.1

10* 15.2

25.9

5

– 22.1

7.6

22.1

7.5

11.4

24

10* 15.2

28.8

30

30

30

30

20

20

25

30

30

30

30

30

LEGEND:

FLA - Full Load Amps

HP - Horse Power

BM - Blower Motor

LRA - Locked Rotor Amps

RLA - Rated Load Amps

MCA - Minimum Circuit Amps

MOCP - Maximum Over Current Protection

FM - Fan Motor (Condenser)

*

Combination of heater modules

MODELS: PQ075 & PQ090

POWER

SUPPLY

(V-Ph-Hz)

380/415-3-50 (4 WIRE)

MODEL NUMBER

DESCRIPTION

PQ075 PQ090

VOLTAGE

RANGE

Min.

342

FM

(each)

COMPR-

ESSOR

(each)

BM

ELECTRIC

HEATER

MCA MOCP

COMPR-

ESSOR

(each)

Max.

FLA RLA LRA HP FLA Nom. kW FLA

– –

5/6 7.6/9.1

457 2.6

(1.9 FOR

PQ090)

12

21

21/21

30

30/30

101

1.5

(STD)

3.4

7.5/10 11.4/15.2 21/23.3

30/30

10

*

/12

*

15.2/18.2 23.3/27 30/30

15

*

22.8

32.8

35

– – 21.2

30

2

(ALT.)

5/6 7.6/9.1

21.2/21.2

30/30

3.6

7.5/10 11.4/15.2 21.2/23.5

30/30

10

*

/12

*

15.2/18.2 23.5/27.3

30/30

15

*

22.8

33 35

BM

ELECTRIC

HEATER

MCA MOCP

RLA LRA HP FLA Nom. kW FLA

– –

5/6 7.6/9.1

8.2

50

3

(ALT.)

24

24/24

30

30/30

2

(STD)

3.6

7.5/10 11.4/15.2

10

24/24 30/30

*

/12

*

15.2/18.2

24/27.3

30/30

15

*

/20

*

22.8/30.4

33/42.5

35/45

25

*

/30

*

38/45.6

52/61.5

60/70

– – 25.1

30

5/6 7.6/9.1

25.1/25.1

30/30

4.7

7.5/10 11.4/15.2 25.1/25.1

30/30

10

*

/12

*

15.2/18.2 25.1/28.6

30/30

15

*

/20

*

22.8/30.4 34.4/43.9

35/45

25

*

/30

*

38/45.6

53.4/62.9

60/70

MODELS: PQ100 & PQ120

POWER

SUPPLY

(V-Ph-Hz)

380/415-3-50 (4 WIRE)

MODEL NUMBER

DESCRIPTION

PQ100 PQ120

VOLTAGE

RANGE

Min.

342

Max.

FM

(each)

COMPR-

ESSOR

(each)

FLA

457 1.9

BM

ELECTRIC

HEATER

MCA MOCP

COMPR-

ESSOR

(each)

RLA LRA HP FLA Nom. kW FLA

5/6

– 28.9

35

7.6/9.1

28.9/28.9

35/35

10.4

55

2

(STD)

3.6

7.5/10 11.4/15.2 28.9/28.9

35/35

10

*

/12

*

15.2/18.2 28.9/28.9

35/35

15

*

/20

*

22.8/30.4

33/42.5

35/45

25

*

/30

*

38/45.6

52/61.5

60/70

– – 30 40

5/6 7.6/9.1

30/30 40/40

3

(ALT.)

4.7

7.5/10 11.4/15.2

10

30/30 40/40

*

/12

*

15.2/18.2

30/30 40/40

15

*

/20

*

22.8/30.4 34.4/43.9

40/45

25

*

/30

*

38/45.6

53.4/62.9

60/70

BM

ELECTRIC

HEATER

MCA MOCP

RLA LRA HP FLA Nom. kW FLA

5/6

– 29.1

35

7.6/9.1

29.1/29.1

35/35

10 74

3

(STD)

4.7

7.5/10 11.4/15.2 29.1/29.1

35/35

10

*

/12

*

15.2/18.2 29.1/29.1

35/35

15

*

/20

*

22.8/30.4 34.4/43.9

35/45

25

*

/30

*

38/45.6

53.4/62.9

60/70

– – 33.6

40

5/6 7.6/9.1

33.6/33.6

40/40

5

(ALT.)

9.2

7.5/10 11.4/15.2 33.6/33.6

40/40

10

*

/12

*

15.2/18.2 33.6/34.3

40/40

15

*

/20

*

22.8/30.4

40/49.5

40/50

25

*

/30

*

38/45.6

59/68.5

60/70

16

ELECTRICAL DATA

MODELS: PQ150 & PQ180

POWER

SUPPLY

(V-Ph-Hz)

380/415-3-50 (4 WIRE)

MODEL NUMBER

DESCRIPTION

PQ150 PQ180

VOLTAGE

RANGE

Min.

342

Max.

FM

(each)

COMPR-

ESSOR

(each)

FLA

457 1.9

BM

ELECTRIC

HEATER

MCA MOCP

COMPR-

ESSOR

(each)

RLA LRA HP FLA Nom. kW FLA

5/6

– 33.6

45

7.6/9.1

33.6/33.6

45/45

12 101

3

(STD)

4.7

7.5/10 11.4/15.2 33.6/33.6

45/45

10

*

/12

*

15.2/18.2 33.6/33.6

45/45

15

*

/20

*

22.8/30.4 34.4/43.9

45/45

25

*

/30

*

38/45.6

53.4/62.9

60/70

– – 38.1

50

5

(ALT.)

5/6 7.6/9.1

38.1/38.1

50/50

9.2

7.5/10 11.4/15.2 38.1/38.1

50/50

10

*

/12

*

15.2/18.2 38.1/38.1

50/50

15

*

/20

*

22.8/30.4

40/49.5

50/50

25

*

/30

*

38/45.6

59/68.5

60/70

BM

ELECTRIC

HEATER

MCA MOCP

RLA LRA HP FLA Nom. kW FLA

7.5

(ALT.)

– – 51 60

17.3

&

16.4

111

&

95

5

(STD)

9.2

10

*

/12

*

15.2/18.2

51/51 60/60

15

*

/20

*

22.8/30.4

51/51 60/60

25

*

/30

*

38/45.6

59/68.5

60/70

– – 54.8

70

13

10

*

/12

*

15.2/18.2 54.8/54.8

70/70

15

*

/20

*

22.8/30.4 54.8/54.8

70/70

25

*

/30

*

38/45.6

63.8/73.3

70/80

MODELS: PQ210 & PQ240

POWER

SUPPLY

(V-Ph-Hz)

380/415-3-50 (4 WIRE)

MODEL NUMBER

DESCRIPTION

PQ210 PQ240

VOLTAGE

RANGE

Min.

342

FM

(each)

COMPR-

ESSOR

(each)

BM

ELECTRIC

HEATER

MCA

Max.

FLA RLA LRA HP FLA Nom. kW FLA

457 1.9

(2.9 FOR

PQ240)

19.2

125

– – 56.2

70

5

(STD)

9.2

10

*

/12

*

15.2/18.2 56.2/56.2

70/70

15

*

/20

*

22.8/30.4 56.2/56.2

70/70

25

*

/30

*

38/45.6

59/68.5

70/70

7.5

(ALT.)

– – 60 70

13

10

*

/12

*

15.2/18.2

60/60 70/70

15

*

/20

*

22.8/30.4

60/60 70/70

25

*

/30

*

38/45.6

63.8/73.3

70/80

MOCP

COMPR-

ESSOR

(each)

BM

ELECTRIC

HEATER

MCA MOCP

RLA LRA HP FLA Nom. kW

7.5

(STD)

FLA

13

– – 62.9

80

10

*

/12

*

15.2/18.2 62.9/62.9

80/80

15

*

/20

*

22.8/30.4 62.9/62.9

80/80

25

*

/30

*

38/45.6 63.8/73.3

80/80

35

*

/40

*

53.2/60.8 82.8/92.3

90/100

19.6

118

10

(ALT.)

– – 65 80

15.1

10

*

/12

*

15.2/18.2

65/65 80/80

15

*

/20

*

22.8/30.4

65/65 80/80

25

*

/30

*

38/45.6 66.4/75.9

80/80

35

*

/40

*

53.2/60.8 85.4/94.9

90/100

MODEL: PQ300 & PQ360

DESCRIPTION

MODEL NUMBER

PQ300 PQ360

POWER

SUPPLY

(V-Ph-Hz)

380/415-3-50 (4 WIRE)

VOLTAGE

RANGE

Min.

342

Max.

FM

(each)

COMPR-

ESSOR

(each)

FLA

457 2.9

BM

ELECTRIC

HEATER

MCA MOCP

COMPR-

ESSOR

(each)

BM

ELECTRIC

HEATER

MCA MOCP

RLA LRA HP FLA Nom. kW

7.5

(STD)

FLA

13

– – 76.4

100

10

*

/12

*

15.2/18.2 76.4/76.4

100/100

15

*

/20

*

22.8/30.4 76.4/76.4

100/100

25

*

/30

*

38/45.6 76.4/76.4 100/100

35

*

/40

*

53.2/60.8 82.8/92.3 100/100

25.6

167

10

(ALT.)

– – 78.5

100

15.1

10

*

/12

*

15.2/18.2 78.5/78.5

100/100

15

*

/20

*

22.8/30.4 78.5/78.5

100/100

25

*

/30

*

38/45.6 78.5/78.5 100/100

35

*

/40

*

53.2/60.8 85.4/94.9 100/100

RLA LRA HP FLA Nom. kW FLA

27.8

198

10

(STD)

– – 83.5

110

15.1

10

*

/12

*

15.2/18.2 83.5/83.5

110/110

15

*

/20

*

22.8/30.4 83.5/83.5

110/110

25

*

/30

*

38/45.6 83.5/83.5

110/110

35

*

/40

*

53.2/60.8 85.4/94.9

110/110

15

(ALT.)

– – 91 110

22.6

10

*

/12

*

15.2/18.2

91/91 110/110

15

*

/20

*

22.8/30.4

91/91 110/110

25

*

/30

*

38/45.6

91/91 110/110

35

*

/40

*

53.2/60.8 94.8/104.3 110/110

Note:

Please refer to page-16 for legend.

17

FAN PERFORMANCE DATA

(DIRECT DRIVE MOTOR)

BLOWER MOTOR

SPEED

HIGH

MEDIUM

LOW

BLOWER MOTOR

SPEED

HIGH

MEDIUM

LOW

CFM

BHP

CFM

BHP

CFM

BHP

0.1

1380

0.81

1250

0.70

1135

0.63

Model No.: PQ036

EXTERNAL STATIC PRESSURE (inch wg.)

0.2

1320

0.80

1200

0.70

1115

0.62

0.3

1340

0.78

1187

0.69

1092

0.61

0.4

1308

0.77

1177

0.68

1062

0.60

0.5

1275

0.75

1166

0.68

1032

0.58

CFM

BHP

CFM

BHP

CFM

BHP

0.1

1675

1.02

1500

0.84

1300

0.72

0.2

1625

0.96

1400

0.81

1250

0.70

Model No.: PQ048

EXTERNAL STATIC PRESSURE (inch wg.)

0.3

1541

0.94

1363

0.80

1200

0.70

0.4

1509

0.92

1340

0.78

1192

0.69

0.5

1477

0.90

1308

0.77

1187

0.68

0.6

1444

0.88

1275

0.75

1176

0.68

0.7

1410

0.86

1237

0.73

1144

0.67

0.8

1376

0.84

1198

0.71

1111

0.66

0.9

1331

0.81

1173

0.70

1032

0.69

952

0.62

0.59

1.0

1285

0.78

1148

0.6

1237

0.73

1144

0.67

989

0.56

Model No.: PQ060

EXTERNAL STATIC PRESSURE (inch wg.)

BLOWER MOTOR

SPEED

HIGH

CFM

BHP

0.1

2055

1.72

0.2

2000

1.63

0.3

1975

1.58

CFM 1850 1800 1768

MEDIUM

BHP 1.53

1.46

1.43

CFM 1650 1600 1558

LOW

BHP 1.31

1.26

1.24

NOTE:

Values include losses for dry coil, 1" thick filters & unit casing.

0.4

1960

1.54

1756

1.39

1550

1.21

0.5

1950

1.50

1738

1.35

1542

1.19

0.6

1925

1.46

1720

1.30

1534

1.16

0.7

1900

1.43

1701

1.27

1526

1.13

0.8

1870

1.39

1683

1.24

1518

1.11

0.9

1825

1.34

1658

1.20

1494

1.08

1.0

1780

1.28

1633

1.16

1470

1.05

18

FAN PERFORMANCE DATA

Airflow,

CFM (L/S)

1800 (849)

2000 (944)

2200 (1038)

2400 (1133)

2600 (1227)

2800 (1321)

3000 (1416)

0.2

0.4

0.6

Model No.: PQ075

External Static Pressure (inch wg.)

0.8

1.0

1.2

1.4

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM

759* 0.43*

0.54*

I

862 0.54

937 0.66

1015 0.78

1088 0.92

1156 1.06

1235 0.98

1270

805*

882 0.65

963 0.78

1039 0.91

1109 1.05

1176 1.19

1242 1.35

1299

845*

861

895

928

962

0.66*

0.79

0.95

1.12

1.31

911

941

971

1001

1044

0.78

0.93

1.09

1.27

1.47

989

1016

1043

1070

1098

0.91

1.06

1.23

1.42

1.63

1062

1080

1111

1135

1161

1.05

1.21

1.38

1.58

1.80

1131

1153

1175

1198

1.19

1.36

1.54

1.75

1196

1216

1237

1258

1.34

1.52

1.71

1.92

1258

1277

1296

1.50

1.68

1.87

1317*

1334*

II

1.6

BHP

1.20

1.51

1.67*

1.85*

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 1.5 HP motor to be used for the unshaded portion.

3. Alt. 2 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PQ090

External Static Pressure (inch wg.)

Airflow,

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

CFM (L/S)

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

2400 (1133) 766* 0.65

* 852 0.78

2600 (1227) 815* 0.78*

877

I

0.92

844 0.93

902 1.07

2800 (1321)

3000 (1416)

3200 (1510)

874

904

933

954

0.91

1008 1.05

1079 1.19

1146 1.34

1210 1.50

1271 1.66

1329 1.83

1384 2.00

1.05

1026 1.20

1095 1.35

1161 1.51

1223 1.67

1283 1.83

1340 2.01

1395 2.19

1.09

927 1.24

976 1.22

1046 1.37

1112 1.52

1176 1.69

1237 1.85

1296 2.03

1352 2.21

1406 2.39

998 1.39

1065 1.55

1130 1.72

1192 1.88

1251 2.06

1309 2.24

1364 2.42

1417 2.61

1.27

953 1.43

1021 1.59

1086 1.76

1153 1.93

1209 2.10

1267 2.28

1323 2.47

1377 2.66

1429 2.85

3400 (1605)

3600 (1699)

933

963

1.46

980 1.63

1044 1.80

1107 1.98

1167 2.16

1226 2.34

1282 2.53

1337 2.72

1.68

1007 1.86

1069 2.04

1129 2.22

1187 2.41

1244 2.60

1299 2.79

II

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 2 HP motor to be used for the unshaded portion.

3. Alt. 3 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PQ100

External Static Pressure (inch wg.)

Airflow,

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

CFM (L/S)

2700 (1274

2800 (1321)

3400 (1605

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

665* 0.68*

723 0.78

674* 0.74*

725

I

0.82

3000 (1416) 690* 0.78*

737 0.93

3200 (1510) 702* 0.87*

744 1.01

716 0.98

732 1.09

756 1.09

766 1.23

785 0.93

848

788 0.96

849

800 1.08

854

804 1.18

857

815 1.31

864

823 1.40

876

1.07

905 1.24

1.12

906 1.29

1.17

910 1.39

1.23

913 1.49

1.45

919 1.61

1.57

927 1.75

3600 (1699)

961 1.39

1012 1.54

1064 1.73

1114 1.90

1160 2.05

962 1.43

1013 1.59

1065 1.76

1115 1.94

1161 2.11

964 1.54

1015 1.71

1067 1.89

1117 2.11

966 1.65

1017 1.83

1069 2.00

1119 2.23

II

970 1.80

1019 1.96

1071 2.15

974 1.90

1021 2.10

766 1.28

793 1.40

852 1.60

904 1.78

954 1.94

997 2.13

3800 (1793)

4000 (1888)

784 1.42

789 1.48

4100(1935)

820 1.58

829 1.67

870 1.75

918

895 1.83

927

1.93

964 2.13

2.03

972 2.23

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 2 HP motor to be used for the unshaded portion.

3. Alt. 3 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

19

FAN PERFORMANCE DATA

Model No.: PQ120

Airflow,

0.2

0.4

3200 (1510) 680* 0.813*

753 1.01

3400 (1605) 697* 0.924*

768

I

1.13

3600 (1699) 716* 1.042*

782 1.26

0.6

External Static Pressure (inch wg.)

0.8

1.0

1.2

1.4

1.87

965 2.02

1029 2.18

1081 2.45

1131 2.72

2.03

970 2.19

1037 2.36

1088 2.63

2.21

985 2.37

1046 2.55

1096 2.83

2.39

995 2.56

1056 2.75

II

1.6

1.8

2.0

CFM (L/S)

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

3800 (1793) 733* 1.17*

797 1.39

4000 (1888)

749 1.31

812 1.54

4200 (1982)

767 1.46

827 1.70

822 1.22

886

834 1.35

897

846 1.48

907

859 1.63

918

872 1.78

929

885 1.95

941

1.44

938 1.56

1006 1.69

1061 1.93

1114 2.17

1165 2.41

1.57

946 1.71

1013 1.85

1068 2.09

1120 2.34

1170* 2.60*

1.72

955 1.86

1021 2.01

1074 2.26

1125 2.53

1174* 2.79*

-

-

-

-

4400 (2076)

785 1.62

843 1.87

899 2.12

953

4600 (2170)

802 1.80

820 1.99

4800 (2265)

859 2.05

875 2.24

913 2.31

966

927 2.51

970

2.59

1006 2.77

2.80

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 3 HP motor to be used.

3. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PQ150

External Static Pressure (inch wg.)

Airflow,

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

2.59

1006 2.77

1066 2.96

1113 3.26

1160 3.57

2.80

1018 2.99

1076 3.19

1123 3.49

1168 3.80

3.02

1030 3.21

1087 3.42

1132 3.74 1177* 4.06*

1.8

2.0

CFM (L/S)

4000 (1888)

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

3800 (1793) 733* 1.17* 797* 1.39*

859 1.63

918

749* 1.31* 812*

I

1.54*

4200 (1982) 767* 1.46*

827 1.70

872 1.78

929

885 1.95

941

1.87

965 2.01

1029 2.18

1081 2.45

1131 2.72

1180* 2.99*

2.03

974 2.19

1037 2.36

1088 2.63

1137 2.91

2.21

985 2.37

1041 2.55

1096 2.83

1145 3.12

2.39

995 2.57

1056 2.75

1105 3.04

1152 3.34

II

-

4400 (2076) 785* 1.62*

843 1.87

4600 (2170) 802* 1.8*

859 2.05

4800 (2265)

5000 (2360)

820 1.99

838 2.18

875

891

2.24

2.45

899 2.12

953

913 2.31

966

927 2.51

981

942 2.73

991

856 2.40

907 2.67

957 2.95

1005 3.25

1042 3.46

1098 3.67

1142 3.99

5200 (2454)

5400 (2548)

5600 (2643)

874 2.62

898 2.86

944 3.12

925 2.90

944 3.15

972

987

3.19

3.45

1019

1032

3.50

3.76

1054

1067

3.71

3.98

1109

1121

3.93

4.21

956 3.41

1002 3.72

1047 4.03

1080 3.26

1133 4.50

1153

1163

4.26

4.54

5800 (2737)

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 3 HP motor to be used for the unshaded portion.

3. Alt. 5 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PQ180

External Static Pressure (inch wg.)

Airflow,

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

CFM (L/S)

4800 (2265)

5000 (2360

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

652* 1.47* 711* 1.69*

668* 1.62*

725 1.85

I

728 1.93

763

740 2.10

773

2.18

826 2.25

2.26

844 2.43

880

888

2.53

928 2.57

970

2.62

933 2.77

975

II

2.92

1032 3.22

1075 3.54

3.12

1037 3.43

1077 3.75

5200 (2454) 683* 1.80*

738 2.03

5400 (2548) 699* 1.97*

752 2.21

5600 (2643) 719* 2.16*

766 2.41

5800 (2737)

731 2.36

781 2.61

6000 (2832)

6200 (2926)

6400 (3020)

6600 (3115)

746 2.58

762 2.80

778 3.05

794 3.30

795

809

824

838

2.84

3.07

3.32

3.58

6800 (3209)

7000 (3303)

7200 (3398)

809 3.40

825 3.70

861 4.00

870 3.70

884 4.00

897 4.30

752 2.28

783

764 2.47

807

776 2.67

818

797 2.78

830

811 2.91

854

830 3.15

865

843

857

3.45

3.67

877

887

2.34

853 2.62

896

2.54

858 2.80

2.74

872 3.03

2.96

882 3.26

3.19

893 3.50

3.36

904 3.75

3.65

914 3.85

3.97

927 4.08

904

913

926

939

948

960

968

2.91

3.12

3.13

3.57

3.61

3.86

4.09

4.41

940

948

955

963

972

981

1013

1030

3.11

3.18

3.45

3.66

3.89

4.19

4.46

4.71

981

1008

1017

1024

1031

1039

1047

1056

3.32

3.54

3.77

4.01

4.26

4.53

4.81

5.10

1042

1047

1053

1059

1066

1073

1077

1088

3.64

3.87

4.11

4.35

4.61

4.88

5.16

5.46

1083

1085

1092

1096

1102

1110

1115

1122

3.97

4.20

4.44

4.70

4.96

5.24

5.52

5.83

878 4.00

902 4.30

952 4.60

890 4.30

911 4.60

964 4.90

914 4.60

928

971

990

5.00

5.30

1041

1048

5.30

5.60

1065

1074

5.70

6.00

1098

1102

6.00

6.30

1129

1137

6.40

6.70

4.90

976 5.30

1001 5.60

1060 5.90

1083 6.30

1113 6.70

1145* 7.10*

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 5 HP motor to be used for the unshaded portion.

3. Alt. 7.5 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

20

FAN PERFORMANCE DATA

Model No.: PQ210

External Static Pressure (inch wg.)

Airflow,

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

CFM (L/S)

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

5800 (2737) 709* 2.21* 759* 2.46*

I

805 2.93

845

6000 (2832) 725* 2.42*

774 2.68

826 3.00

857

6200 (2926) 741* 2.65*

788 2.90

839 3.35

870

6400 (3020) 757* 2.90*

802 3.17

6600 (3115)

773 3.16

824 3.42

6800 (3209)

808 3.23

846 3.56

7000 (3303)

7200 (3398)

7400 (3492)

7600 (3587)

7800 (3681)

8000 (3775)

8200 (3870)

815

835

855

881

895

903

918

3.56

4.00

4.12

4.40

4.70

5.10

5.45

856 3.95

872

882 4.50

907

912 5.00

927

4.20

4.72

5.40

849

875

892

911

925

938

954

968

988

3.60

3.80

4.40

4.70

5.01

5.25

5.50

882

898

4.11

910

928

935

959

974

987

3.01

892 3.30

3.30

901 3.60

3.60

912 3.90

3.90

925 4.30

4.13

945 4.50

4.45

961 4.80

927

935

946

956

966

977

3.62

973 3.80

1031 4.12

1067 4.46

1103 4.81

3.80

982 4.20

1039 4.60

1074 4.92

1109 5.28

4.20

998 4.50

1047 4.85

1081 5.19

1111 5.55

4.60

1028 4.90

1058 5.20

1088 5.50

1122 5.85

4.80

5.11

1037

1047

5.10

5.41

1064

1074

5.42

5.75

1091

1106

5.78

6.16

1129

1137

4.73

972 5.00

990 5.34

1058 5.69

1082 6.05

1111 6.42

1145* 6.81*

5.00

978 5.35

1015 5.65

1064 5.98

1087 6.30

1120 6.8

1150* 7.23*

5.30

996 5.63

1032 5.93

1079 6.37

1095 6.75

1125 7.12

5.54

5.93

1008

1027

5.90

6.30

5.90

1001 6.25

1054 6.65

1067 7.08

945 5.72

1002 6.32

1016 6.70

1067 7.12

1046

1056

6.30

6.74

1086

1099

6.70

7.11

1099 7.11

II

6.15

6.47

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 5 HP motor to be used for the unshaded portion.

3. Alt. 7.5 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PQ240

External Static Pressure (inch wg.)

Airflow,

0.2

0.4

0.6

0.8

1.0

1.2

1.4

1.6

1.8

2.0

CFM (L/S)

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

6000 (2832) 577* 2.03* 586* 2.13*

689 2.24

741

586* 2.15* 642* 2.25*

695

I

2.36

746

6200 (2926

6400 (3020) 595* 2.27* 649* 2.24*

701 2.50

751

6600 (3115) 605* 2.39* 657* 2.51*

708 2.64

757

6800 (3209) 614* 2.52* 665* 2.64*

715 2.78

763

7000 (3303) 623* 2.66*

673 2.78

7200 (3398) 653* 2.80*

681 2.94

721

728

2.93

3.09

768

774

7400 (3492) 642* 2.95*

689 3.09

7600 (3587) 651* 3.10*

697 3.26

7800 (3681) 660* 3.26*

705 3.43

8000 (3775

670 4.43

714 3.60

735

743

750

757

3.25

3.43

3.60

3.79

780

787

793

800

8200 (3870)

8400 (3964)

8600 (4058)

8800 (4152)

9000 (4247)

679 3.61

689 3.79

698 3.98

707 4.17

716 4.38

707 3.65

730 3.98

739 4.17

747 4.38

756 4.59

764 3.97

806

772 4.17

813

780 4.38

820

787 4.59

826

795 4.81

833

2.36

790 2.68

837

2.49

795 2.83

841

2.63

799 2.98

845

2.78

804 3.13

850

2.93

809 3.29

854

3.09

814 3.46

858

3.25

819 3.63

862

3.43

824 3.81

867

3.61

828 3.97

872

3.79

835 4.18

875

3.98

841 4.38

882

4.17

847 4.59

4.38

853 4.80

4.59

859 5.02

887

892

898

4.81

865 5.24

903

5.04

871 5.48

909

3.02

882 3.12

926

3.17

886 3.28

928

3.33

889 3.44

931

3.49

893 3.61

935

3.66

897 3.79

938

3.83

900 3.97

941

4.01

904 4.15

945

4.20

908 4.35

948

4.39

913 4.55

952

4.59

917 4.75

956

4.79

921 4.97

960

5.01

926 5.18

964

5.23

930 5.41

968

5.45

935 5.64

972

5.68

940 5.88

977

5.93

945 6.13

981

3.48

967

3.64

969

3.81

972

3.99

975

4.17

978

4.36

981

4.55

984

4.75

987

3.84

1006 4.22

4.01

1009 4.39

4.19

1011 4.58

4.38

1014 4.77

4.57

1016 4.97

4.76

1019 5.17

4.96

1022 5.38

5.17

1024 5.59

4.96

990

5.17

994

5.38

1027 5.81

5.60

1030 6.04

5.40

997 5.83

1034 6.28

5.62

1001 6.07

1037 6.52

5.86

1004 6.31

1040 6.77

6.10

1008 6.56

1044 7.02

6.34

1012 6.81

6.60

II

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 7.5 HP motor to be used for the entire range with either drive I & II.

3. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

21

FAN PERFORMANCE DATA

Model No.: PQ300

Airflow,

CFM (L/S)

0.2

0.4

1.6

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

8200 (3870) 679* 3.61* 707* 3.65*

8400 (3964) 689* 3.79*

730 3.98

8600 (4058) 698* 3.98*

739 4.17

8800 (4152) 707* 4.17*

747 4.38

9000 (4247) 716* 4.38*

756 4.59

9200 (4341)

726 4.42

9400 (4436)

9600 (4530)

744 4.84

9800 (4624)

735

754

4.61

5.07

764

773 4.83

781

4.71

5.21

790 5.31

10000 (4719)

763 5.31

10200 (4813)

777 5.57

10400 (4907)

782 5.83

10600 (5002)

792 6.09

10800 (5096)

801 6.37

11000 (5191)

810 6.65

11200 (5286)

820 6.95

799

808

817

825

834

843

852

5.56

5.82

6.09

6.36

6.65

6.94

7.24

764

I

0.6

3.97

External Static Pressure (inch wg.)

8000 (3775 670* 3.43* 714* 3.60*

757 3.79

800

806

772 4.17

813

780 4.38

820

787 4.59

826

795 4.81

833

803 4.92

840

810 5.07

848

818 5.31

855

826

834

5.56

6.22

862

869

842 6.48

874

850 6.76

884

859 7.04

892

867 7.33

900

875 7.63

907

883 7.94

915

0.8

1.0

3.98

841 4.38

882 4.79

4.17

847 4.59

887 5.01

4.38

853 4.80

4.59

859 5.02

892

898

5.23

5.45

4.81

865 5.24

5.04

871 5.48

5.27

875 5.72

5.51

884 5.97

903

909

914

920

5.68

5.93

6.17

6.43

5.76

891 6.22

6.02

897 6.49

6.38

904 6.76

6.66

911 7.04

6.94

918 7.33

7.23

925 7.63

1.2

926 6.69

932 6.97

938 7.25

945 7.53

951 7.83

958 8.13

7.53

932 7.93

7.84

939 8.25

8.15

946 8.57

978 9.10

1.4

921 4.97

960

926 5.18

964

930 5.41

968

935 5.64

972

940 5.88

977

945 6.13

981

950 6.39

986

956 6.65

991

961 6.92

995

967 7.20

1001

7.41

7.70

1029

1034

7.90

8.20

1063

1067

8.41

8.71

972

978

7.49

7.78

1006

1011

7.99

8.29

1039

1044

8.50

8.81

984 8.13

1016 8.60

1049 9.13

990 8.40

1022 8.92

1071

1076

II

9.02

9.33

964 8.45

996 8.72

1028 9.25

971 8.77

1002 9.05

1.8

2.0

5.40

997 5.83

1034 6.28

5.62

1001 6.07

1037 6.52

5.86

1004 6.31

1040 6.77

6.10

1008 6.56

1044 7.02

6.34

1012 6.81

1047 7.28

6.60

1016 7.07

1051 7.55

6.86

1021 7.34

1055 7.83

7.13

1025 7.62

1059 8.12

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 7.5 HP motor to be used for the unshaded portion.

3. Alt. 10 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

Model No.: PQ360

External Static Pressure (inch wg.)

Airflow,

CFM (L/S)

0.2

0.4

9600 (4530) 645* 5.40* 675* 5.70*

9800 (4624) 655* 5.60* 685* 5.90*

10000 (4719) 665* 5.80*

695 6.10

10200 (4813) 675* 6.00*

705 6.30

715 6.50

10400 (4907) 685* 6.20*

10600 (5002)

695 6.40

10800 (5096)

705 6.60

725

735

6.70

6.90

11000 (5191)

715 6.80

745 7.10

11200 (5286)

725 7.00

11400 (5380)

735 7.20

11600 (5474)

745 7.40

11800 (5569)

755 7.60

755 7.30

765

775

785

7.50

7.70

7.90

12000 (5663)

765 7.80

12200 (5757)

775 8.00

12400 (5852)

785 8.20

12500 (5899)

795 8.40

795

805

815

825

8.10

8.30

8.50

8.70

0.6

RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP

705 6.10

730

715

I

6.30

740

725 6.50

750

735 6.70

760

745 6.90

770

755 7.10

780

765 7.30

790

775 7.50

800

785 7.70

810

795

805

7.90

8.10

820

830

815 8.30

840

825

835

8.50

8.70

850

860

845

855

8.90

870

9.10

880

0.8

1.0

1.2

6.50

760 7.00

790 7.40

6.70

770 7.20

800 7.60

6.90

780 7.40

810 7.80

7.10

790 7.60

820 8.00

7.30

800 7.80

830 8.20

7.50

810 8.00

840 8.40

7.70

820 8.20

7.90

830 8.40

850

860

8.60

8.80

1.4

825 7.90

850

835 8.10

860

845 8.30

870

855 8.50

880

865 8.70

890

875 8.90

900

885 9.10

910

895 9.30

920

1.6

8.40

880

8.60

890

8.80

900

9.00

910

1.8

II

8.80

910

9.00

920

9.20

930

2.0

9.40

9.60

9.80

9.40

940 10.00

9.20

920

9.40

930

9.60

950 10.20

9.80

960 10.40

9.60

940 10.00

970 10.60

9.80

950 10.20

980 10.80

8.10

840 8.60

8.30

850 8.80

8.50

860 9.00

8.70

870 9.20

870

880

890

900

9.00

9.20

9.40

9.60

905

915

925

9.50

9.70

930

940

10.00

10.20

960

970

10.40

990 11.00

10.60 1000 11.20

9.90

950 10.40

980 10.80 1010 11.40

935 10.10

960 10.60

990 11.00 1020 11.60

8.90

880 9.40

9.10

890 9.60

910 9.80

945 10.30

970 10.80 1000 11.20 1030 11.80

920 10.00

955 10.50

980 11.00 1010 11.40 1040 12.00

9.30

900 9.80

930 10.20

965 10.70

990 11.20 1020 11.60 1050 12.20

9.50

910 10.00

940 10.40

975 10.90 1000 11.40 1030 11.80 1060 12.40

Notes:

1. Values include losses for filters, unit casing and wet coils.

2. Standard 10 HP motor to be used for the unshaded portion.

3. Alt. 15 HP motor to be used for the shaded portion.

4. Bordered regions indicate alternative drives I & II.

*

For bold figures, consult your nearest COOLINE representative for proper selection of drives. Drives shall be field supplied & installed.

22

SOUND LEVEL DATA

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:

1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).

SE= (CFM x TSP)/6362 x BHP (see step 4 & table below).

2. Read dBA level from respective graph at operating BHP & SE(%).

3. Knowing RPM, select proper row from sound power factor table and add dBA level to each values in the row to obtain

Sound Power Level (dB re 10

-12 watts).

4. Calculate TSP (Total Static Pressure) as follows:

TSP = ISP + ESP

ESP (External Static Pressure) from Job Specification.

ISP (Internal Static Pressure) Calculate from table below.

FACE VELOCITY

(FPM)

INTERNAL STATIC PRESSURE (inch wg.)

200

300

400

450

2 ROW

0.42

0.67

0.88

1.02

3 ROW

0.44

0.73

0.95

1.13

500 1.16

1.29

NOTE:

Pressure drop across filter, coil and casing are included in ISP.

4 ROW

0.47

0.78

1.05

1.23

1.49

23

SOUND LEVEL DATA

MODELS: PQ036 - PQ060

SOUND POWER FACTOR TABLE

VALUES GIVE TO SOUND POWER

Octave Band

Center Frequency – Hz

493-887 RPM

887-1750 RPM

1750-2500 RPM

63

– 7.5

– 8

– 8

125

+ 0.5

+ 0.5

+ 0.5

250

+ 7.5

+ 7

+ 7

500

+ 10.5

+ 7

+ 7

1000

+ 5.5

+ 8

+ 5

2000

+ 2

+ 1.5

+ 4.5

4000

– 1

– 1.5

– 1.5

8000

– 6.5

– 6.5

– 6.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:

1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).

SE= (CFM x TSP)/6362 x BHP

2. Read dBA level from above graph at operating BHP & SE(%).

3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power

Level (dB re 10

-12 watts).

24

SOUND LEVEL DATA

MODELS: PQ075 - PQ090

SOUND POWER FACTOR TABLE

VALUES GIVE TO SOUND POWER

Octave Band

Center Frequency – Hz

251-495 RPM

495-990 RPM

990-1953 RPM

1953-2050 RPM

63

– 6

– 6.5

– 7

– 7

125

+ 2

+ 1.5

+ 1.5

+ 1.5

250

+ 11.5

+ 8

+ 8

+ 8

500

+ 8

+ 10.5

+ 7

+ 7

1000

+ 5.5

+ 5

+ 8

+ 5

2000

+ 2

+ 1.5

+ 1.5

+ 4.5

4000

– 1

– 1.5

– 2

– 2

8000

– 6.5

– 7

– 7.5

– 7.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:

1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).

SE= (CFM x TSP)/6362 x BHP

2. Read dBA level from above graph at operating BHP & SE(%).

3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power

Level (dB re 10

-12 watts).

25

SOUND LEVEL DATA

MODELS: PQ100 - PQ210

Octave Band

Center Frequency – Hz

211-417 RPM

417-835 RPM

835-1647 RPM

63

– 4.5

– 5.5

– 5.5

SOUND POWER FACTOR TABLE

VALUES GIVE TO SOUND POWER

125

+ 3

+ 2.5

+ 2.5

250

+ 12

+ 8.5

+ 8

500

+ 8

+ 10.5

+ 7

1000

+ 5

+ 4.5

+ 7

2000

+ 2

+ 1.5

+ 1

4000

– 1.5

– 2

– 2.5

8000

– 7

– 7.5

– 7.5

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:

1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).

SE= (CFM x TSP)/6362 x BHP

2. Read dBA level from above graph at operating BHP & SE(%).

3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power

Level (dB re 10

-12 watts).

26

SOUND LEVEL DATA

MODELS: PQ240 - PQ300

Octave Band

Center Frequency – Hz

255-443 RPM

443-887 RPM

887-1750 RPM

63

– 3.5

– 4

– 4

SOUND POWER FACTOR TABLE

VALUES GIVE TO SOUND POWER

125

+ 4

+ 3.5

+ 3.5

250

+ 12.5

+ 9

+ 8.5

500

+ 8

+ 10

+ 7

1000

+ 4.5

+ 4

+ 7

2000

+ 1.5

+ 1

+ 0.5

4000

– 2

– 2.5

– 3

8000

– 7.5

– 8

– 8

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite the center of blower inlet:

1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).

SE= (CFM x TSP)/6362 x BHP

2. Read dBA level from above graph at operating BHP & SE(%).

3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power

Level (dB re 10

-12 watts).

27

SOUND LEVEL DATA

MODEL: PQ360

Octave Band

Center Frequency – Hz

267-507 RPM

507-1014 RPM

1014-2000 RPM

63

– 3

– 3.5

– 4

SOUND POWER FACTOR TABLE

VALUES GIVE TO SOUND POWER

125

+ 4.5

+ 3.5

+ 3.5

250

+ 12.5

+ 9

+ 8.5

500

+ 7.5

+ 10

+ 7

1000

+ 4.5

+ 4

+ 6.5

2000

+ 1.5

+ 0.5

+ 0.5

4000

– 2

– 2.5

– 3

8000

– 7.5

– 8

– 8

To obtain Sound Pressure Level measured 5 ft. (1.6 m) directly opposite to the center of blower inlet:

1. From performance table at operating conditions, find BHP, RPM & Static Efficiency (SE).

SE= (CFM x TSP)/6362 x BHP

2. Read dBA level from above graph at operating BHP & SE(%).

3. Knowing RPM, select proper row from above table and add dBA level to each values in the row to obtain Sound Power

Level (dB re 10

-12 watts).

28

STATIC PRESSURE DROP (inch wg.)

MODELS: PQ036 - PQ060

COMPONENT

1 HEATER MODULE

2 HEATER MODULE

900

0.12

0.19

1200

0.12

0.19

1400

0.12

0.19

CFM

1600

0.13

0.20

1800

0.14

0.21

2000

0.15

0.21

MODELS: PQ075 - PQ090

COMPONENT

1 HEATER MODULE

2 HEATER MODULE

CFM

1600 1800 2000 2200 2400 2600 3000 3200 3400 3600 3800

0.11

0.12

0.13

0.13

0.14

0.15

0.16

0.16

0.17

0.18

0.18

0.18

0.19

0.19

0.19

0.20

0.20

0.21

0.21

0.22

0.23

0.23

MODELS: PQ100 - PQ150

COMPONENT

1 HEATER MODULE

2 HEATER MODULE

CFM

2600 2800 3000 3400 3800 4000 4200 4800 5200 5800

0.04

0.06

0.04

0.06

0.05

0.07

0.08

0.10

0.10

0.12

0.11

0.14

0.12

0.15

0.14

0.18

0.16

0.18

0.20 0.22

MODELS: PQ180 - PQ210

COMPONENT

1 HEATER MODULE

2 HEATER MODULE

CFM

4800 5200 5600 6000 6200 6800 7000 7400 7600 7800 8200

0.08

0.08

0.08

0.08

0.08

0.09

0.10

0.10

0.10

0.11

0.11

0.14

0.14

0.14

0.14

0.14

0.16

0.16

0.16

0.16

0.17

0.17

MODELS: PQ240 - PQ360

COMPONENT

1 HEATER MODULE

2 HEATER MODULE

CFM

6000 6600 7200 7800 8400 9000 9600 10200 10800 11400 12000

0.05

0.06

0.07

0.08

0.09

0.10

0.11

0.12

0.14

0.15

0.16

0.17

0.18

0.19

0.20

0.21

0.13

0.22

0.14

0.23

0.15

0.24

BLOWER MOTOR EFFICIENCY

MOTOR HP

EFFICIENCY (%)

0.75

0.81

1.0

0.81

1.5

0.80

NOTE:

Convert BHP to watts using following formula

Watts = 746 x BHP

Motor Efficiency

2.0

0.81

3.0

0.81

5.0

0.80

7.5

0.81

10.0

0.80

29

UNIT DIMENSIONS

PQ036 - PQ060

NOTE:

1. All dimensions are in mm (dimensions in brackets are in inches).

30

24

[0.94]

UNIT DIMENSIONS

PQ075 - PQ150

POWER SUPPLY CONN

AIR OUT

CONDENSER COIL

D

B

SIDE VIEW

CONDENSER COIL

COMPRESSOR / CONTROLS

ACCESS PANEL

CONTROL COMPARTMENT

ACCESS PANEL

FOR BLOWER & MOTOR

M

CONDENSATE DRAIN OUTLET

3/4" NPT

AIR IN

(OPTIONAL)

FRESH AIR OPENING/HOOD

AIR IN SUPPLY AIR

TOP VIEW

RETURN AIR

K J H N

L

CONDENSER COIL

P

A

SUPPLY AIR

OPENING

RETURN AIR

OPENING

FRONT VIEW

Ø 12.7 ( 0.5) MOUNTING HOLES

(2 EACH SIDE)

SIDE VIEW

FILTER

ACCESS

PANEL

DRAIN OUTLET

DIMENSIONS

MODEL

A B C D E F G H J K L M N O P

PQ075 - PQ090

2080(81.89) 1162(45.75) 1034(40.71) 1114(43.86) 308(12.15) 550(21.64) 798(31.4) 300(11.81) 251(9.87) 396(15.59) 152(5.98) 175(6.88) 24(0.94) 171(6.73) 1775(69.88)

PQ100 - PQ150

2212(87.1) 1408(55.43) 1085(42.72) 1372(54) 255(10.03) 707(27.84) 790(31.1) 367(14.46) 190(7.48) 476(18.74) 150(5.91) 145(5.71) 48(1.89) 200(7.87) 1907(75.08)

NOTE:

1. All dimensions are in mm (dimensions in brackets are in inches).

31

UNIT DIMENSIONS

PQ180 - PQ360

CONDENSER COIL

A\IR IN

CONTROLS

ACCESS PANEL

ACCESS PANEL

FOR BLOWER & MOTOR

CONTROL COMPARTMENT

S

M

CONDENSATE DRAIN OUTLET

3/4" NPT

POWER INLET

POWER INLET

F

COMPRESSOR

ACCESS PANEL

A\IR IN

CONDENSER COIL

AIR IN SUPPLY AIR

TOP VIEW

RETURN AIR

AIR OUT

K U H N

CONDENSER COIL SUPPLY AIR

OPENING

RETURN AIR OPENING

(OPTIONAL)

FRESH AIR OPENING/HOOD

D

B

SIDE VIEW

G

X

L

A

FRONT VIEW

X G

D

B

16 x 25mm

MOUNTING SLOT (3EACH SIDE)

MOUNTING SLOT (4EACH SIDE-PY/PQ360)

SIDE VIEW

CONTROL BOX

ACCESS PANEL

DRAIN OUTLET

DIMENSIONS

MODEL

A B C D F G H K L N R S M U

PQ180 - PQ210

2794(110) 1778(70) 1266(49.83)1715(67.52) 1737(68.37) 197(7.75) 817(32.17) 720(28.35) 1200(47.25) 83(3.27) 912(35.9) 666(26.22) 194(7.64) 171(6.73)

X

-

PQ240 - PQ300

3048(120) 2196(86.44) 1446(56.94) 2135(84.1) 2152(84.72) 324(12.76) 915(36.02) 740(29.13) 1200(47.25) 84(3.31) 1050(41.34) 666(26.22) 289(11.38) 194(7.64)

PQ360

3683(145) 2184(86) 1446(56.94)2125(83.66) 2184(86) 42(1.65) 938(36.93) 527(20.75) 97(3.83) 1000(39.37) 680(26.77) 254(10)

-

372(14.65) 1125(44.29)

NOTE:

1. All dimensions are in mm (dimensions in brackets are in inches).

32

Performex-1

TM

CONTROLLER: OPERATION & FUNCTIONS

LCD display:

a) Room temperature display b) Mode of operation (Cool/Heat/Auto/Fan system control) c) Set temperature d) Compressor Status - ON/OFF/FAULT e) Error Codes

1. ON/OFF:

Press the ON/OFF button & the unit shall be switched ON. A status Led adjacent to this button shall light up indicating the unit is switched ON. To shut off the unit, press this button again.

2. MODE:

Press the mode button to select the desired mode. On selection the corresponding icon shall be displayed on the LCD display panel.

3. TEMPERATURE RANGE AND SETTING:

The operating temperature range is 16

0

C to 30

0

C (61

0

F to 86

0

F), both inclusive. Press the UP or DN button to select the desired temperature. The temperature setting is effective only for the Cool, Heat and Auto modes.

4. INDOOR (EVAPORATOR) FAN:

There is one indoor fan with single fan speed. When fan speed on LCD panel is

HIGH, indoor fan will always turns on. Indoor fan can be set off, when the compressor is cut off by setting the fan speed to AUTO on the LCD panel by pressing Fan button. By pressing the Fan button again the fan speed can resume to HIGH.

5. COOL MODE:

Whenever the unit is started in cool mode (without Pump Down Solenoid-PDS), the compressors will be turned on one by one depending on the load requirement of the unit.

6. HEAT MODE

(HEATER MODEL): Whenever the unit is started in heat mode, the heaters shall be switched ON one by one to meet the load requirement.

33

7. LEAD/LAG OPERATION:

Whenever a compressor needs to be on, the controller will turn on the compressor with the shorter accumulated run time provided its 3 minutes minimum off time has lapsed. Otherwise the other compressor will on first. Similarly, the compressor with the longer accumulated run time will be the first one to be cut off. This is to load the compressors evenly over long run period. Balance loading is enabled when compressor #1 lead option is disabled.

8. AUTO MODE:

In Auto mode, operating mode will be selected automatically between Heat and Cool mode, depending on the Room Temperature and Set Temperature.

PROTECTION

The following safeties are provided for the system:

1. Compressor high pressure protection (option)

2. Compressor low pressure protection

TYPICAL HIGH AND LOW VOLTAGE FIELD WIRING CONNECTIONS

L1 L2 L3 N

(FOR 380V ONLY)

FUSED DISCONNECT SWITCH

OR CIRCUIT BREAKER

PACKAGE UNIT

CONTROL PANEL

N

G

L1

L2

L3

LEGEND

ECB - ELECTRONIC CONTROL BOARD

HVTB - HIGH VOLTAGE TERMINAL BLOCK

LI - LINE1

L2 - LINE2

L3 - LINE3

N - NEUTRAL TERMINAL BLOCK

G - GROUND

FIELD WIRING

CONTROL WIRES-INTERCONNECTING

( USE 16 TO 22 AWG WIRE)

A B +5V GND

INDOOR THERMOSTAT

34

TYPICAL SCHEMATIC WIRING DIAGRAM

NOTE:

1. Refer to next page for legend, notes & wiring diagram for optional items.

2. Refer to unit control box (inside panel) for exact wiring diagram.

35

TYPICAL SCHEMATIC WIRING DIAGRAM

LEGEND

AR

AFS

ATB

BM

BMC

CC

CCA

CB

AUXILIARY RELAY

AIRFLOW SWITCH

AUXILIARY TERMINAL BLOCK

BLOWER MOTOR

BLOWER MOTOR CONTACTOR

COMPRESSOR CONTACTOR

AUXILIARY CONTACT

CIRCUIT BREAKER

C. HTR CRANKCASE HEATER

COMP COMPRESSOR

ECB

FCS

ELECTRONIC CONTROL BOARD

FAN CYCLING SWITCH

F

FL

FM

FMC

FUSE

FUSE LINK

FAN MOTOR (CONDENSER)

FAN MOTOR CONTACTOR

L3

LPS

LUG

NTB

O/L

OHT

PDS

FR

HC

FAULT RELAY

HEATER CONTACTOR

HPS HIGH PRESSURE SWITCH

HVTB HIGH VOLTAGE TERMINAL BLOCK

HTR

JP

L1

L2

HEATER

JUMPER

LINE 1

LINE 2

LINE 3

LOW PRESSURE SWITCH

LUG GROUND

NEUTRAL TERMINAL BLOCK

OVER LOAD

OVER HEAT THERMOSTAT

PUMP DOWN SOLENOID

SSPS SOLID STATE PROTECTIVE SYSTEM

SD SMOKE DETECTOR

TRANS TRANSFORMER

T'STAT THERMOSTAT

T.O.P.

THERMAL OVERLOAD PROTECTION

UVM

_ _ _

UNDER VOLTAGE MONITOR

FIELD WIRING

+ DISCONNECT TAB - 1/4"

SPLICE-CLOSED END

TERMINAL BLOCK OR TERMINATION POINT

NOTES

1. POWER SUPPLY, 380/415V-3Ph.-50Hz.

2. ANY WIRE REPLACEMENT SHOULD BE OF 90 0 C OR ITS

EQUIVALENT. USE COPPER CONDUCTOR WIRES ONLY.

3. IF PDS & HEATERS ARE FACTORY INSTALLED, PLEASE

READ BROKEN LINES AS CONTINUOUS LINES.

4. POWER MUST BE SUPPLIED TO CRANKCASE HEATER FOR

MINIMUM OF 12 HOURS PRIOR TO SYSTEM START UP.

IF POWER IS OFF 6 HOURS OR MORE, CRANKCASE

HEATER MUST BE ON FOR 12 HOURS BEFORE OPER-

ATING THE SYSTEM.

FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RE-

SULT IN COMPRESSOR DAMAGE.

5. FUSED DISCONNECT SWITCH OR CIRCUIT BREAKER

TO BE PROVIDED BY CONSUMER WITH RATING AS

RECOMMENDED BY COOLINE.

6. COMPRESSORS ARE PROVIDED WITH INTERNAL OVERLOAD.

7. IF COMPRESSOR IS SUPPLIED WITH SSPS, CONNECT AS

SHOWN. PLEASE ALLOW 2-3 MINUTES FOR SSPS SWITCH

TO CLOSE, BEFORE STARTING THE UNIT.

8. IF ANY CHANGE IN DIP SWITCH SETTING IS REQUIRED,

TURN OFF POWER FIRST & SET REQUIRED SETTING.

36

PARTS LIST

MODEL NUMBER

COMPRESSOR

CONDENSER FAN MOTOR

BLOWER MOTOR

BLOWER WHEEL

CONDENSER FAN PROPELLER

CONTACTOR COMPRESSOR

CONTACTOR BLOWER MOTOR

CAPACITOR FAN MOTOR

AIR FLOW SWITCH

LOW PRESSURE CONTROL

FAN GRILLE

FILTER DRIER

PQ036L

800-684-08

800-555-26

800-546-94

800-707-34

800-225-02

800-095-01

800-736-27

800-353-15

800-005-02

800-557-00

800-625-46

800-531-08

PQ048L

800-672-52

800-555-26

800-546-94

800-707-34

800-225-02

800-095-01

800-736-27

800-353-15

800-005-02

800-557-00

800-625-46

800-531-08

PQ060L

800-643-01

800-555-26

800-546-95

800-707-34

800-225-02

800-095-01

800-736-27

800-353-15

800-005-02

800-557-00

800-625-46

800-531-08

MODEL NUMBER

COMPRESSOR

CONDENSER FAN MOTOR

BLOWER MOTOR

BLOWER WHEEL

CONDENSER FAN PROPELLER

CONTACTOR COMPRESSOR

CONTACTOR BLOWER MOTOR

CONTACTOR COND. FAN MOTOR

AIRFLOW SWITCH

EXPANSION VALVE

DISTRIBUTOR

PQ075L PQ090L PQ100L PQ120L PQ150L PQ180L PQ210L PQ240L PQ300L PQ360L

800-674-78 800-684-09 800-672-52 800-674-25 800-674-78

800-674-81

800-674-67

800-674-38 800-674-19 800-674-12 800-674-72

800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-545-68 800-555-06 800-555-06 800-555-06

800-544-13 800-544-16 800-544-16 800-544-17 800-544-17 800-544-40 800-544-40 800-544-73 800-544-73 800-544-74

800-707-46 800-707-46 800-707-02 800-707-02 800-707-02 800-707-02 800-707-02 800-707-23 800-707-23 800-707-94

800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-23 800-224-28 800-224-28 800-224-28

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-736-22 800-736-22 800-736-22 800-736-22 800-736-22

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-098-55 800-098-55 800-098-55 800-098-55

N.A.

800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01 800-095-01

800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02 800-005-02

800-195-35 800-195-17 800-195-20 800-195-22 800-195-35 800-182-00 800-182-00 800-185-00 800-186-00 800-186-00

800-194-18 800-194-15 800-194-15 800-194-18 800-194-18 800-196-00 800-196-00 800-194-01 800-192-02 800-196-16

LOW PRESSURE CONTROL 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00 800-557-00

HIGH PRESSURE CONTROL (OPTION) 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00 800-558-00

FAN GRILLE

FILTER DRIER

800-625-29 800-625-29 800-625-29 800-625-29 800-625-29 800-625-74 800-625-74 800-625-38 800-625-38 800-625-38

800-531-08 800-531-08 800-531-08 800-531-08 800-531-08 800-531-05 800-531-05 800-531-05 800-531-05 800-531-01

37