Climate control - Pentair/Schroff

Climate control - Pentair/Schroff
Climate control
electronics PROTECTION
05/2016
PRODUcT cATALOG
WWW.SCHROFF.PENTAIR.co.uk
Main Catalogue
Climate control – Overview
Content
Cabinets . . . . . . 1
Wall mounted
cases . . . . . . . . . 2
Accessories for
cabinets and wall
mounted cases . 3
19" fans
쮿 Pusher fans
쮿 Circulation fans
쮿 Cooling capacity up to 2000 W
Climate control . 4
Electronics
cases . . . . . . . . . 5
Air filtered fans
Subracks/
19" chassis . . . . 6
쮿 Simple to fit - just clips in
쮿 Protection type up to IP 55
쮿 Airflow volume up to 770 m3/h
Front panels,
plug-in units . . . 7
Systems . . . . . . . 8
Power supply
units . . . . . . . . . . 9
Accessories
Backplanes . . . 10
쮿
쮿
쮿
쮿
Heaters
Speed control
Thermostats
Hygrostats
Connectors, front
panel component
system . . . . . . . 11
Appendix . . . . . 12
36108005 (01192002, 01192009, 01194003, 01108012 00902001 00908001)
4.0
SCHROFF Further information: www.varistar.de E 05/2016
ELECTRONICS PROTECTION
Climate control – Overview
Overview . . . . . . 4.0
Cooling
concepts . . . . . . . . 4.2
Air/water heat exchangers
쮿 Complete cabinet solutions
쮿 For industry and data centers
쮿 Cooling capacities up to 40 kW
19" fan trays . . . 4.4
Air filtered
fans . . . . . . . . . . . . 4.20
Accessories
Heaters . . . . . . . . . .
Fans . . . . . . . . . . . .
Speed control . . . .
Thermostats . . . . .
Hygrostats . . . . . . .
4.56
4.59
4.60
4.61
4.64
Air/water heat
exchangers . . . . 1.224
36108006 (01108004 01108002 01102004 00505033 01008020 01006040)
SCHROFF.PENTAIR.CO.UK
4.1
1 9" fan traysMain Catalogue
Climate control – 19" fan trays
Content
Cabinets . . . . . . 1
Wall mounted
cases . . . . . . . . . 2
Accessories for
cabinets and wall
mounted cases . 3
Climate control . 4
Electronics
cases . . . . . . . . . 5
01102012
Standards/Approvals
Subracks/
19" chassis . . . . 6
쮿 Mechanical protection to DIN EN ISO 13857
Contact protection to DIN EN ISO 13857
Electrical safety to EN 60335 part 1
Plastics self-extinguishing to UL 94 V0
쮿 19" assembly area in accordance with:
IEC 60297-3-101
Airflow
Front panels,
plug-in units . . . 7
Vertical airflow
(continual warming)
Diverted airflow
(effective cooling)
Systems . . . . . . . 8
Power supply
units . . . . . . . . . . 9
Backplanes . . . 10
01109055
With vertical airflow the air becomes steadily warmer
as it rises through the cabinet.
Connectors, front
panel component
system . . . . . . . 11
01109054
By using the 1 U airflow element, air is introduced from
the front and extracted to the rear. Now all subassemblies receive the same cooling air.
Appendix . . . . . 12
4.4
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays
Overview . . . . . . 4.4
19 " fan traysMain Catalogue
19" fan trays
쮿 To cool single components and assemblies in 19" cabinets
쮿 High airflow rate for directed heat removal
쮿 With axial or radial fans
쮿 For voltages 230 VAC, 115 VAC or 24 VDC
쮿 CE- approvals
19" fans
19" fans
쮿 19" circulation fan, height 1 U
1 U with/without
front switch . . . . . . 4.6
쮿 230 VAC, 115 VAC and 24 VDC
1 U speedcontrolled and
monitored . . . . . . . 4.8
쮿 Up to 1000 m3/h
쮿 With/without mains switch or with temperature-dependent
speed control
01109002
19" pusher fans
19" blower units
쮿 Tangential fan, height 2 U
Pusher fan, 2 U
with tangential
blower . . . . . . . . . . 4.9
쮿 230 VAC and 115 VAC
쮿 Up to 320 m3/h
01192009
쮿 19" pusher fan, height 2 U
쮿 230 VAC and 115 VAC
Pressure fan, 2 U,
(160, 220 mm
deep) . . . . . . . . . . . . 4.10
쮿 Up to 530 m3/h
01194005
쮿 19" pusher fan, height 3 U
Pusher fan, 3 U. . . 4.12
쮿 230 VAC and 115 VAC
쮿 Up to 570 m3/h
ServicePLUS
configuration . . . . 4.14
쮿 Variable air outlet with/without pipe connection, upward or to
rear
Accessories
01102017
19" airflow
element . . . . . . . . . 4.15
AC fans . . . . . . . . . . 4.16
ServicePLUS from page 4.19
DC fans . . . . . . . . . . 4.16
e.g. other airflow capacities
e.g. supply voltages
e.g. other dimensions
e.g. custom solutions
ServicePLUS . . . 4.19
www.schroff.biz/ServicePLUS
30407004
SCHROFF.PENTAIR.CO.UK
4.5
Climate control – 19" fan trays
19" fan 1 U
19" fan traysMain CatalogueP art number in bold fac e type: ready for despatch withi n 2 working daysP art number in normal type: ready for des patch within 1 0 working days
쮿 Mechanical strain relief for mains cables
쮿 Can be adapted to subracks
쮿 Contact protection in accordance with DIN EN ISO 13857
Delivery comprises (ready to connect)
01194002
Item
1
Qty
1
2
3a
3/6
1
b3
1
Description
19" circulation fan, 1 U,
cover/base plate, St, 1 mm, finish AlZn, with perforation;
front panel 1 U, AI, 3 mm, anodised
Fan, see Order Information
AC with IEC connector (mains input IEC 60320),
incl. safety clamp for mechanical strain relief
DC version with connecting cable, cable length 2.5 m
43,5
Order Information
436
137
81
24 VDC
Part no.
115 VAC
Part no.
230 VAC
Part no.
10713-103
10713-102
10713-100
10713-107
10713-106
10713-104
20713-240
20713-244
20713-243
85
193
137
330
KTA44857
KTA44858
Replacement fan 1 piece
483
KTA44306
Side panel connecting bracket between europacPRO
subrack and fan, including fixing material kit, PU 4 pieces
Equipment cable SCHUKO/UTE SCHUKO/UTE plug,
IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable, BS British Standard plug,
IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable, USA USA plug,
IEC 60320 socket, 2 m, 1 piece
21101-954
60103-131
60103-137
60103-141
ServicePLUS see page 4.19
Technical data
Voltage
Frequency in Hz
Number of fans
Airflow volume in m3/h (3/6 fans)
Noise level in dB(A) (3/6 fans)
Power consumption in W (3/6 fans)
Max. stat. pressure in Pa
Permissible ambient temperature in °C
Lifespan in h L1040 °C
Lifespan in h L1055 °C
230 VAC
50
440/845
56.5/59.4
45/90
73
60
3/6
520/1000
60.2/62.9
42/84
88
115 VAC
50
60
3/6
440/845
520/1000
56.5/59.4
60.2/62.9
46.5/93
43.5/87
73
88
–40 ... +70 °C
43500
20000
24 VCDC
3/6
506/970
60.5/63.3
24/48
68
Note
쮿 Fan dimensioning see page 4.18
쮿 Replacement fans see chapter Climate control - Accessories
쮿 Versions with multiple fans see ServicePLUS configuration
page 4.14
4.6
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays
19" fan 1 U with front switch
19" fan trays
쮿 Front-mounted illuminated mains switch on AC devices,
coupled with additional rear mains outlet; mechanical strain
relief for mains input and mains output cables
쮿 Can be adapted to subracks
쮿 Contact protection in accordance with DIN EN ISO 13857
Delivery comprises (ready to connect)
01194003
Item
1
Qty
1
2
3a
3/6
1
b3
1
Description
19" circulation fan, 1 U, top/base plate, St, 1 mm,
finish AlZn, with perforation;
front panel 1 U, AI, 3 mm, anodised
Fan, see Order Information
AC version with mains switch, illuminated green;
plug (mains input IEC 60320) incl. safety clamp for
mechanical strain relief;
coupled mains output socket (IEC 60320)
DC version with mains switch and connecting cable,
cable length 2.5 m
Order Information
01197002
24 VDC
Part no.
115 VAC
Part no.
230 VAC
Part no.
10713-111
10713-110
10713-108
10713-115
10713-114
10713-112
20713-240
20713-244
20713-243
43,5
KTA44857
436
137
81
KTA44858
85
193
137
330
Replacement fan 1 piece
483
KTA45963
Side panel connecting bracket between europacPRO
subrack and fan, including fixing material kit, PU 4 pieces
Equipment cable SCHUKO/UTE SCHUKO/UTE plug,
IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable, BS British Standard plug,
IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable, USA USA plug,
IEC 60320 socket, 2 m, 1 piece
Mains cable, IEC IEC 60320 C14 plug,
IEC 60320 C13 socket, 2.5 m, 1 piece
21101-954
60103-131
60103-137
60103-141
60197-053
ServicePLUS see page 4.19
Technical data
Voltage
Frequency in Hz
Number of fans
Airflow volume in m3/h (3/6 fans)
Noise level in dB(A) (3/6 fans)
Power consumption in W (3/6 fans)
Max. stat. pressure in Pa
Permissible ambient temperature in °C
Lifespan in h L1040 °C
Lifespan in h L1055 °C
230 VAC
50
440/845
56.5/59.4
45/90
73
60
3/6
520/1000
60.2/62.9
42/84
88
115 VAC
50
60
3/6
440/845
520/1000
56.5/59.4
60.2/62.9
46.5/93
43.5/87
73
88
–40 ... +70 °C
43500
20000
24 VDC
3/6
506/970
60.5/63.3
24/48
68
쮿 Fan dimensioning, see page 4.18
쮿 Replacement fans, see chapter Climate control - Accessories
쮿 Versions with multiple fans see ServicePLUS configuration
page 4.14
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.7
Climate control – 19" fan trays
19" fan 1 U, with
speed control and function monitoring
19" fan trays
쮿 Low noise through temperature dependent airflow volume
쮿 Range selectable: 20 ... 40 °C and 30 ... 50 °C
쮿 External sensor, at sensor breakage max speed will be set
automatically
쮿 Function control with LEDs and via potential-free contact
쮿 Contact protection in accordance with DIN EN ISO 13857
쮿 2 versions, 24 VDC or 230 VAC
Delivery comprises (ready for connection)
Qty
1
2
3
4
3/6
1
1
Description
19" circulation fan, 1 U; cover/base plate, St, 1 mm,
finish Al-Zn, with perforation front panel 1 U, AI, 3 mm,
anodised
DC fan, see Order information
Connecting cable, length 2.5 m, open-ended
Temperature sensor for speed control, NTC resistor,
cable length 1.5 m
01198001
43,5
Photo shows 19" fan unit with 3 fans, without switch
Item
1
436
137
Order Information
81
D1
137
D2
D
24 VDC
Without switch D
230 VAC
With switch
Without switch
mm
Part No.
mm
Part No.
Part No.
193
10713-099
250
19713-121
–
330
10713-098
397
–
19713-006
85
D1
KTA44857
D2
483
KTA44858
01107050
Airflow capacity with one fan
[m³/h]
200
180
160
140
120
100
80
60
40
20
0
0
Accessories
Filter mat, class G 2 for 3 fans, PU 3 pieces
Filter mat, class G 2 for 6 fans, PU 3 pieces
60713-169
60713-170
Technical data
10
20
30
40
50
60 [°C]
01112050
Monitoring signal
Voltage AC version (fans 24 VDC)
Voltage DC version
Number of fans
Max. airflow volume in m3/h
Noise level in dB(A)
Max. stat. pressure in Pa
Power consumption in W
Permissible ambient temperature °C
Life in h L1040 °C
86 ... 260 VAC
24 VDC (21 ... 27)
3
6
467
895
63.5
66.4
70
70
15.9
31.8 W
–20 ... +65 °C
70000
Technical data Regulation/monitoring
Control range
Sensor
Sensor
connector
Signal at
kta43400
n = rotating speed, S = signal, nA = speed threshold value "Alarm"
Signalling
Changeover switch between 20 ... 40 °C and 30 ... 50 °C
External NTC resistor, cable length 1.5 m
Rear-mounted plug contact, max. rotation speed in case
of sensor breakage
Speed < 30 % nominal speed; switch-on delay < 4 s, signal
delay < 1 s (see monitoring signal)
Display via LEDs; potential-free contact (changeover),
switching capacity 5 W, max. switching voltage 170 V,
open collector on request
쮿 Fan dimensioning see page 4.18
ServicePLUS see page 4.19
4.8
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays
Pusher fan, 2 U, with tangential fan
19" fan trays
쮿 High airflow volume
쮿 Integrated filter mat
쮿 2 versions:
- LE1: 19" bolt-on dimension, fan unit is wider than 19"
- LE2: 19" reduced width, for easy assembly
Delivery comprises (ready to connect)
01192009
Item
1
Qty
1
2
3
1
1
Description
Blower unit 2 U, with grille, PA 6.6, UL 94 V-0,
front grille 2 U, PPO, UL 94 V-0;
filter mat, synthetic fibre, filter class G 2
Fan
Terminal block
Order Information
Description
A3532
LE1: Pusher fan 2 U, tangential blower
LE2: Pusher fan 2 U, tangential blower
Spare filter mat PU 10 pieces
115 VAC
Part no.
230 VAC
Part no.
60713-003
60713-001
60713-004
60713-002
20705-008
Dimensions
Voltage
Frequency in Hz
Airflow volume in m3/h
Noise level in dB(A)
Max. stat. pressure in Pa
Power consumption in W
Permissible ambient temperature in °C
Lifespan in h
115 VAC
230 VAC
50
60
50
60
320
330
320
330
59
62
59
62
65
70
65
70
30
40
37
46
–20 ... +65 °C
30000
Note
쮿 24 VDCon request
쮿 Fan dimensioning, see page 4.18
01103056
ServicePLUS see page 4.19
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.9
Climate control – 19" fan trays
19" pusher fan 2 U
(depth 160 mm or 220 mm)
19" fan trays
쮿 Integrated air deflector prevents heat buildup in the assemblies
mounted below
쮿 Optionally with rear additional fan, 2 U, for active cooling of
assemblies beneath the pusher fan
쮿 Can be adapted to subracks
쮿 Contact protection in accordance with DIN EN ISO 13857
01194005
Delivery comprises (ready to connect)
Item
1
Qty
1
2
3a
3
1
3b
1
3c
1
Description
19" pusher fan 2 U, case, St, 1 mm, finish AI-Zn;
front grille 2 U, PPO, UL 94 V-0 Filter mat, synthetic fibre,
filter class G 2
Fan
AC-version with plug (mains input, IEC 60320), incl. safety
clamp, mechanical strain relief for mains input cable;
socket to connect an optional supplementary fan
Wide AC input range with DC fans, version as 3 a,
additionally speed-controlled and monitored
DC version with connecting cable, cable length 2.5 m
Note
쮿 Supplementary fan for AC version see page 4.11
쮿 Fan dimensioning, see page 4.18
01103054A3527V
ServicePLUS see page 4.19
Order Information
Description
Front panel Al, anodised
86 ... 260 VAC (fan 24 VDC)
515 m3/h
Part no.
24 VDC
515 m3/h
Part no.
Front panel, plastic, black
115 VAC
115 VAC
230 VAC
230 VAC
300/330 m 3/h 445/530 m3/h 300/330 m3/h 445/530 m 3/h
Part no.
Part no.
Part no.
Part no.
For board depth 160 mm
19713-540
10713-537
10713-520
10713-536
For board depth 220 mm
–
10713-529
–
–
Replacement fan piece
20713-240
20713-240
20713-147
20713-244
Equipment cable SCHUKO/UTE SCHUKO/UTE plug, IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable BS British Standard plug, IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable USA USA plug, IEC 60320 socket, 2 m, 1 piece
Side panel connecting bracket between europac subrack, including fixing material kit
Side panel connecting bracket between europacPRO subrack and fan, including fixing material kit, PU 4 pieces
Spare filter mat PU 3 pieces
10713-518
10713-534
–
20700-001
10713-526
20713-243
60103-131
60103-137
60103-141
21101-104
21101-954
60713-501
Technical data with 3 fans
Voltage
Frequency in MHz
Airflow volume in m3/h
Noise level in dB(A)
Max. stat. pressure in Pa
Power consumption in W
Permissible ambient temperature in °C
Life in h, 1) at 40 °C, 2) at 55 °C
4.10
24 VDC
515
59.8
68
24
–20 ... +70 °C
20000 2)
SCHROFF PRODUCT CATALOG E 05/2016
24 VDC
115 VAC
230 VAC
515
59.8
68
24
–20 ... +70 °C
20000 2)
50
300
52.2
41
42
50
300
52.2
41
42
60
50
60
330
445
530
56.1
55.2
58.2
41
78
88
33
46.5
43.5
–40 ... +70 °C
50000 1)
200002)
60
50
60
330
445
530
56.1
55.2
58.5
41
78
88
33
45
42
–40 ... +70 °C
50000 1)
20000 2)
ELECTRONICS PROTECTION
Climate control – 19" fan trays
Supplementary fans with housing
for pusher fan 2 U
19" fan trays
쮿 Extra 2 U useable space:
By using a built-on fan, components mounted below the
19" pusher fan can be cooled
쮿 No additional voltage supply necessary: connection is via
19" pusher fan, 2 U
쮿 Contact protection in accordance with DIN EN ISO 13857
Delivery comprises (ready to fit and connect)
01194006
Item
1
2
3
Qty
1
4
1
Description
Housing with grille, St, 1 mm, finish AIZn
Fan
Cable with plug (electrical connection via socket on
19" blower fan); safety clamp (mechanical strain relief
for mains input cable)
Order Information
Description
Supplementary fans with housing for
pusher fan 2 U
115 VAC
Part no.
230 VAC
Part no.
10713-532
10713-530
Technical data with 3 fans
KTA44447
Voltage
Frequency in MHz
Airflow volume in m3/h
Noise level in dB(A)
Max. stat. pressure in Pa
Permissible ambient temperature in °C
Power consumption in W
Life in h at 55 °C
115 VAC
50
60
130
155
51
54
44
62
-40 ... +70
30
24
20000
230 VAC
50
60
130
155
51
54
44
62
-40 ... +70
27
21
20000
Note
쮿 24 VDC version available on request
쮿 Fan dimensioning see page 4.18
01103055
ServicePLUS see page 4.19
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.11
Climate control – 19" fan trays
19" pusher fan 3 U
19" fan trays
With cover plates, this pusher fan can be re-fitted to different
cooling concepts
쮿 Ventilation directed accurately to the electronics
쮿 Air infeed from front, air exits at the top rear of cabinet (guided
upwards by cover plates or via hoses to rear and upwards)
쮿 Contact protection in accordance with DIN EN ISO 13857
Delivery comprises (ready for connection)
Item
1
Qty
1
2
3
1
1
01102017
Description
Case, St, 1 mm, AIZn; perforated hinged front panel, Al,
2.5 mm; filter mat, synthetic fibre, filter class G 2 in
accordance with DIN EN 779
Radial fan with mains fuse
Plug (mains input, IEC 60320); safety clamp, mechanical
strain relief for mains input cable
Order Information
Description
115 VAC
Part no.
230 VAC
Part no.
19" pusher fan 3 U
10713-547
Accessories
Equipment cable SCHUKO/UTE SCHUKO/UTE plug,
IEC 60320 C13 socket, 2.5 m, 1 piece
Equipment cable, BS British Standard plug, IEC 60320 C13
socket, 2.5 m, 1 piece
Equipment cable, USA USA plug,
IEC 60320 socket, 2 m, 1 piece
Side panel connecting bracket between europac subrack
and fan, including fixing material kit, PU 4 pieces
Side panel connecting bracket between europacPRO
subrack and fan, including fixing material kit, PU 4 pieces
Spare filter mat PU 3 pieces
10713-546
60103-131
60103-137
60103-141
21101-958
21101-954
60713-868
Technical data
01103052
ServicePLUS see page 4.19
Voltage
Frequency in MHz
Airflow volume in m3/h
Noise level per fan in dB(A)
Max. stat. pressure in Pa
Power consumption in W
Max. ambient temperatures in °C
Life in h at 55 °C
115 VAC
50
60
510
570
62
64
320
410
55
65
-20 ... +50
20000
230 VAC
50
60
510
570
62
64
320
410
58
75
-20 ... +50
20000
Note
쮿 Wide input voltage range 90 V ... 260 VAC available on request
쮿 Temperature control and function monitoring (alarm via
RS 232) on request
쮿 Air deflector plates for other cooling concepts see page 4.13
쮿 Fan dimensioning see page 4.18
4.12
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays
Air deflector plate for 19" pusher fan 3 U
19" fan trays
쮿 For 19" pusher fan 3 U
Order Information
Item
7
8
9
10
Description
Air deflector plate to front, St, 1 mm,
finish AlZn
Air outlet to rear: upper cover plate,
without perforation, 1 mm, finish AlZn
Air deflector plate with hose connection
on upper rear, external diameter 80 mm,
St, 1 mm, finish AlZn
Air deflector plate with hose connection
to rear, external diameter 80 mm, St, 1
mm, finish AlZn
Qty/PU
Part no.
1
20713-504
1
20713-505
1
20713-503
1
20713-502
01103053
ServicePLUS see page 4.19
Connecting cable with connector socket
19" fan trays
쮿 Connecting cable with connector for AC fans (25 mm and
38 mm height) and DC fans (38 mm height), cable length 1 m
Delivery comprises
Item
1
KTA43091
Qty
1
Description
Cable, PVC (2 x 0.75 mm²), 1 m long, with 2 FASTON
connectors 2.8 x 0.5 mm, DIN 46343 T1
Order Information
Description
Connecting cable with plug
SCHROFF.PENTAIR.CO.UK
Part no.
21101-246
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.13
Climate control – 19" fan trays
ServicePLUS: Configuration with assembly
19" fan trays
쮿 You can plan and build up your product yourself using the order
information table below
쮿 Dimensions of fan trays
– Height 1 U
– Width 19"
– Depth 193, 300, 467, 604 mm
for 3, 6, 9 or 12 fans
쮿 Create your 19" fan trays from individual parts (assembled
within 10 working days)
Example configuration
Qty
1
1
1
6
01102012
Description
Housing, 1 piece
Front panel with switch, AC, 1 piece
Filter mat, 1 piece
Fan, AC, height 25 mm;
mounted at position 1, 3, 5, 7, 9, 11
Order no.
20713-213
20713-231/05
60713-246/05
20700-001/05
Order Information
Fan height
a44537
Fan housing
1)
AC (230 V)
DC
AC (230 V)
DC
cover/base
plate, St, 1 mm,
finish AlZn,
with perforation
1 U, Al, 3 mm,
anodised;
includes cable
harness
1 U, Al, 3 mm,
anodised;
connecting
cable, 2.5 m;
includes cable
harness
1 U, Al, 3 mm,
anodised;
mains switch,
illuminated
green; includes
cable harness
1 U, Al, 3 mm,
anodised;
mains switch,
illuminated
green;
connecting
cable, 2.5 m;
includes cable
harness
can only be
fitted where fan
height is 25 mm
mm
Front panel without switch
Front panel with switch
Filter mat G 2
Fans
1 piece
1 piece
1 piece
1 piece
1 piece
PU 3 pieces
see page
25
20713-212
20713-220/
05
20713-224/
05
20713-228/
05
20713-236/
05
60713-243
4.16
38
20713-216
20713-220/
05
20713-224/
05
20713-228/
05
20713-236/
05
–
4.16
25
20713-213
20713-221/
05
20713-225/
05
20713-229/
05
20713-237/
05
60713-244
4.16
38
20713-217
20713-221/
05
20713-225/
05
20713-229/
05
20713-237/
05
–
4.16
25
20713-214
20713-222/
05
20713-226/
05
20713-230/
05
20713-238/
05
60713-245
4.16
38
20713-218
20713-222/
05
20713-226/
05
20713-230/
05
20713-238/
05
–
4.16
25
20713-215
20713-223/
05
20713-227/
05
20713-231/
05
20713-239/
05
60713-246
4.16
38
20713-219
20713-223/
05
20713-227/
05
20713-231/
05
20713-239/
05
–
4.16
KTA44857
KTA44858
kta44859
kta44860
1) Fan housing cannot be ordered without fans
Note
쮿 Unused fan mounting positions are covered with foam material
쮿 Versions for 115 V or with switch available on request
쮿 Fan dimensioning see page 4.18
4.14
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays
1 U air deflector chassis for
19" fan trays
19" fan trays
쮿 Optimised cooling together with 19" fan trays
쮿 Vertical buildup of heat is avoided by means of improved airflow
쮿 Fitting options:
– One fan tray: cool air is drawn in from the front and guided
upwards
– Two fan trays: cool air is drawn in from the front, directed
upwards and guided to the rear (see application diagram)
쮿 Versions:
– With solid front panel to direct airflow
– With perforated front panel to allow air to flow in/out
쮿 Optional filter mat, simple to swap during operation
01109001
1 U air deflector chassis (bottom) with 1 U fan tray (top)
01109002
Delivery comprises (assembled)
Item
1
Qty
1
2
2
3a
1
3b
1
4
1
Description
Air deflector plate, St, 1 mm, finish Zincor,
width 432.8 mm (without side panel)
Side panel, St, 1.5 mm, finish Zincor; with 19" mounting
bracket, powder-coated (see Order information for
colour)
Front panel, perforated, St, 1.5 mm, finish Zincor,
powder-coated (see Order information for colour);
two quick-release fasteners, black
Front panel, solid, St, 1.5 mm, finish Zincor, powdercoated (see Order information for colour);
two quick-release fasteners, black
Assembly kit
Order Information
1 U air deflector chassis Depth Colour
for
mm
19" fan trays
Part no.
Front panel,
perforated
Part no.
Front panel,
solid
193
RAL 7035
for single-row fan trays
193
RAL 9005
(3 fans)
193
RAL 9006
330
RAL 7035
for double-row fan
330
RAL 9005
trays (6 fans)
330
RAL 9006
Accessories
Filter mat, class G 2 for 3 fans, PU 3 pieces
Filter mat, class G 2 for 6 fans, PU 3 pieces
10713-140
10713-142
10713-146
10713-148
10713-144
10713-150
10713-141
10713-143
10713-147
10713-149
10713-145
10713-151
60713-169
60713-331
01109051
Application: air deflector chassis mounted below 19" fan tray,
guides the cool air upwards from front; second air deflector
chassis at top guides the warm air to the rear
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.15
Climate control – 19" fan trays
AC fans/replacement fans
19" fan trays
Delivery comprises
Item
1
Qty
1
Description
Fan (width 119 mm, depth 119 mm)
Order Information
Description
Height Airflow volume
mm
m3/h
Type A
25
84
Type B
25
108
Type C
38
162
Assembly kit for fan PU 1 kit
115 VAC
Part no.
230 VAC
Part no.
20713-146
20713-142
20713-147
20713-244
20700-001
20713-243
21102-013
Dimensions AC fans
01108005
Type
Frequency in Hz
Airflow volume in m3/h
Noise level per fan in dB(A)
Max. static pressure in Pa
Max. ambient temperature in °C
Power consumption in W
Dimensions: height in mm
(width 119 mm × depth 119 mm)
Type A
50 60
84 90
29 30
23 21
70 70
8
7
25
Type B
50 60
108 120
34 38
41 41
70 70
14 11
25
Type C
50 60
162 192
37 41
73 88
70 70
15 14
38
쮿 Please order connecting cable separately, see page 4.13
쮿 Please order protective grille separately, see page 4.17
DC fans/replacement fans
19" fan trays
Delivery comprises
Item
1a
1b
Qty
1
1
Description
Fan, height 38 mm, with plug connection
Fan, height 25.5 mm, connecting cable, length 55 mm,
connector with 2 x FASTON connectors (2.8 x 0.8 mm)
Order Information
Height Airflow volume
Power
consumption
mm
m3/h
W
25.5
171
5.3
38
184
8
38
184
8
38
184
8
Assembly kit for fan PU 1 kit
Input
voltage
V
24
12
24
48
Part no.
20713-172
20713-241
20713-240
20713-242
21102-013
01108005
Technical data DC fans
Voltage in VDC
Dimensions: height in mm
(width 119 mm × depth 119 mm)
Airflow volume in m3/h
Noise level per fan in dB(A)
Max. stat. pressure in Pa
Max. ambient temperature in °C
Power consumption in W
24
25
12
38
24
38
48
38
171
41.5
50.5
70
7
184
42
68
70
8
184
42
68
70
8
184
42
68
70
8
쮿 Please order connecting cable for 38 mm high fans separately,
see page 4.13
쮿 Please order protective grille separately, see page 4.17
4.16
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays
Protective grille to snap-in
19" fan trays
쮿 Protective grille for direct mounting on AC and DC fans
Delivery comprises
Qty
1
Ø 50
105
119
Item
1
Description
Fibre glass reinforced plastic (PA), black, in accordance
with DIN 31001, UL 94 V-0
Order Information
Description
Protective grille, plastic, to snap-in
105
Part no.
60225-052
6,5
Ø9
119
min. 9
13,5
3,8
01108053
Protective grille, plastic, to screw-on
19" fan trays
쮿 Protective grille for AC and DC fans
쮿 Grille may be mounted on a front panel or the wall of the
housing
Item
1
Ø 50
127
113,5
Delivery comprises
Qty
1
Description
Fibre glass reinforced plastic (PA), black, in accordance
with DIN 31001, UL 94 V-0
Order Information
113,5
Description
Protective grille, plastic, to screw-on
Assembly kit for plastic grille (4 screws, 4 washers, 4 nuts
M4), PU 1 set
6,5
Ø8
21102-014
90°
Ø 4,5
127
Part no.
60225-053
3,8
01108054
Protective grille, metal, to screw-on
19" fan trays
쮿 Protective grille for direct mounting on AC and DC fans
4,7
쮿 Optimised noise level and air resistance
Item
1
104,7
115,0
Delivery comprises
Qty
1
Description
St, 1 mm
Order Information
104,7
115,0
Description
Protective grille, metal, to screw-on
Assembly kit for metal grille (4 screws, 4 washers, 4 nuts
M4), PU 1 set
1,8
5,5
Part no.
60197-019
21102-015
01109050
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.17
Climate control – 19" fan trays
19" fan trays
19" fan dimensioning
V (m3/h)
For local heat dissipation, the airflow volume required to expel
the heat produced is calculated.
Note
The cabinet ventilation is not taken into account here.
The required airflow volume is calculated as follows:
V= (f x Pv)/ΔT
Pv (W)
The air constant f = 3.3 m3K/Wh.
ΔT is the temperature difference between the ambient
temperature of the sub-assembly and that of the air drawn in.
Example of readings
- Pv = 600 W
- air sucked in: 25 °C
- permissible ambient temperature of the sub-assembly = 30 °C
A41771
1. ΔT = Ti – Tu = 30 °C – 25 °C = 5 K
2. From Pv = 600 W to the curve for ΔT =5 K
3. From the intersection point to the airflow volume V = 400 m3/h
4.18
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – 19" fan trays ServicePLUS
assembly
Assembled by professionals. Double benefit!
Fitting of all mechanical, electrical and
electronic components by our specialists
쮿 No additional charge
modification
Small changes. Large impact.
Custom drillings, cut-outs and special colours
for off-the-shelf products
쮿 Download CAD data, send modifications to us
쮿 Ready for dispatch within 10 working days
쮿 Ready for dispatch within 15 working days
19" fan trays ServiceP LUS
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.19
Ai r filtered fanMain Catalogue
Climate control – Air filtered fan
Content
Cabinets . . . . . . 1
Wall mounted
cases . . . . . . . . . 2
Accessories for
cabinets and wall
mounted cases . 3
Climate control . 4
Electronics
cases . . . . . . . . . 5
Subracks/
19" chassis . . . . 6
01105012
Front panels,
plug-in units . . . 7
Systems . . . . . . . 8
Simple to fit without tools by clipping in
(can also be bolted)
01108014
Easy tool-less change of filter mat
01108015
Power supply
units . . . . . . . . . . 9
Backplanes . . . 10
01108016
Connectors, front
panel component
system . . . . . . . 11
Fluted filter to increase degree of ingress protection
from IP 54 to IP 55
01108013
Easy tool-less wiring with spring clamp connector
Ai r filtered fan
Appendix . . . . . 12
4.20
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Air filtered fan
Overview . . . . . 4.20
Air filtered fanMain C atalogue
Air filtered fans, ingress protection from IP 54 to IP 55
in accordance with IEC 60529
쮿 Simple to fit without tools by clipping in (can also be bolted)
How to dimension
air filtered fans . . 4.22
쮿 Easy conversion from pressure to suction operation
Reading example . 4.22
쮿 Easy tool-less change of filter mat
EMC solutions . . . 4.22
쮿 7 performance classes with 6 different assembly dimensions
Air filtered fans
쮿 Airflow capacity of 25 m3/h ... 770 m3/h (FL 100 ... FL 600)
쮿 3 supply voltages (230 VAC, 115 VAC, 24 VDC)
쮿 Outlet/inlet filter
쮿 Fluted filter to increase degree of ingress protection from
IP 54 to IP 55
Air filtered fans
FL 100 . . . . . . . . . . 4.23
FL 200 . . . . . . . . . . 4.24
FL 225 . . . . . . . . . . 4.25
FL 250 . . . . . . . . . . 4.26
FL 300 . . . . . . . . . . 4.27
FL 500 . . . . . . . . . . 4.28
FL 600 . . . . . . . . . . 4.29
쮿 Side by side mounting of several air filtered fans is possible
Air filtered fans
Outlet/inlet filters
Fluted filters
01108017
01108026
01108016
ServicePLUS
e.g. special colours
e.g. other cabinet dimensions
e.g. EMC solutions
e.g. custom solutions
www.schroff.biz/ServicePLUS
30407004
SCHROFF.PENTAIR.CO.UK
4.21
Climate control – Air filtered fans
Air filtered fan calculations
To establish the size of the air-filtered fan required, calculate the air
throughput necessary to dissipate the amount of heat contained in the
cabinet.
The necessary airflow volume (at sea level) is calculated thus:
V = f x (PV - PS ) / ∆T with
V = airflow volume
f = air constant = 3.3 m³ K/Wh
PV = thermal power loss
(sum of heat emitted by the equipment in the cabinet)
PS = radiant power
(heat that is radiated from the cabinet
without additional ventilation)
∆T = temperature difference between the air drawn in (ambient
temperature Tu) and the exhaust air (internal cabinet temperature Ti),
∆T = Ti -Tu
01108017
Reading example
The devices in the cabinet produce e.g. a power loss of 840 W. Of these
840 W, the cabinet releases 340 W to the environment via its surfaces. The
air sucked in from outside the cabinet has a temperature of 20 °C.
A maximum temperature of 40 °C is to be permitted in the cabinet.
So which air filtered fan should be employed?
1. PV = 840 W, PS = 340 W, read-off point PV - PS = 500 W
2. ∆T = Ti - Ta = 40 °C - 20 °C = 20 °C = 20 K
3. On the characteristic for 20 K we obtain, at PV - PS = 500 W,
a minimum necessary airflow volume of V = 80 m³/h.
4. An FL 250 air filtered fan should be used that gives an airflow volume
of 131 m³/h or, if used in combination with the FLA 250 exhaust filter,
of 95 m³/h.
FL 100 + FLA 100
FL 100
FL 200 + FLA 200
FL 200
FL 225 + FLA 225
FL 225
FL 250 + FLA 250
FL 250
FL 300 + FLA 300
FL 300
FL 500 + FLA 500
FL 500
FL 600 + FLA 600
FL 600
kta45245
EMC solutions
4
Air filtered fansMain CatalogueP art number in bold face type: ready for despatch within 2 working daysPart number i n normal type: ready for despatch within 1 0 working days
쮿 EMC shielding in accordance with your requirements
쮿 Customised developments
Delivery comprises
3
Item
1
2
3
4
2
1
Description
Protective fan grille
Fan
EMC hood
FLA outlet/inlet filter
01108070
4.22
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Air filtered fans
Air filtered fan FL 100
쮿 Airflow volume 25 m3/h
Air filtered fansPart num ber in bold face type: ready for despatch within 2 working daysPart num ber in normal type: ready for despatch within 10 working days
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, NEMA type 12
쮿 Simple to fit without tools by clipping in
Delivery comprises (completely assembled)
01108018
Item
1
Qty
1
2
3
4
1
1
1
Description
Front grille and case, plastic, ABS, RAL 7035,
self-extinguishing, UL 94 V-0
Filter, filter class G 3 (EN 779)
Fan
2 wire connection, length 310 mm
Order Information
Description
24 VDC
Part no.
115 VAC
Part no.
Air filtered fan FL 100
60715-142
60715-141
Air outlet/inlet filter FLA 100
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 100 and FLA 100,
filter class G 3 (EN 779), PU 5 pieces
230 VAC
Part no.
60715-140
60715-156
60715-182
Technical data
01108019
Air outlet/inlet filter FLA 100
Voltage
Frequency
Airflow volume with filter
(free blowing)
Combination FL + FLA
Max. static pressure
Noise level (in accordance
with EN ISO 3741, 50 Hz)
Operating temperatures
Power consumption
Filter efficiency
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
25/29 m3/h
115 VAC
50/60 Hz
25/29 m3/h
24 VDC
DC
25 m3/h
16/18 m3/h
38 Pa
33 dB(A)
16/18 m3/h
38 Pa
33 dB(A)
16 m3/h
38 Pa
33 dB(A)
–15 ... +55 °C –15 ... +55 °C
12/11 W
11/11 W
88 %
88 %
40000 h
40000 h
CE, UL, cUL, GOST
–15 ... +55 °C
2.4 W
88 %
80000 h
Note
01108020
92
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
109
109
92
Replacement filter IP 54
92
92
109
109
62
4
4
01108057
19
01108058
Air filtered fan FL 100
Air outlet/inlet filter FLA 100
Sheet thicknesses 1 ... 2 mm - cut-out 92 x 92 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 93 x 93 mm
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.23
Climate control – Air filtered fans
Air filtered fan FL 200
쮿 Airflow volume 61 m3/h
Air filtered fans
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, with fluted filter IP 55, NEMA type 12
쮿 Simple to fit without tools by clipping in (can also be bolted)
Delivery comprises (Completely assembled)
01108018
Item
1
Qty
1
2
3
4
1
1
1
Description
Front grille and case, plastic, ABS, RAL 7035,
self-extinguishing, UL 94 V-0
Filter, filter class G3 (EN 779)
Fan
Connection AC (terminal strip),
connection DC (2 wires, 310 mm long)
Order Information
Description
Air outlet/inlet filter FLA 200
Fluted filter IP 55
01108019 01108021
01108020
125
125
115 VAC
Part no.
Air filtered fan FL 200
60715-145
60715-144
Air outlet/inlet filter FLA 200
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 200 and FLA 200,
filter class G 3 (EN 779), PU 5 pieces
Fluted filter IP 55 for FL 200 and FLA 200,
filter class G 4 (EN 779), PU 5 pieces
230 VAC
Part no.
60715-143
60715-157
60715-183
60715-187
Technical data
Replacement filter IP 54
Voltage
Frequency
Airflow volume with
IP 54 filter (free blowing)
Airflow volume with
IP 55 filter (free blowing)
Combination FL + FLA IP 54
Combination FL + FLA IP 55
Max. static pressure IP 54
Max. static pressure IP 55
Noise level in accordance
with EN ISO 3741, 50 Hz)
Max. ambient temperature
Power consumption
Filter efficiency IP 54
Filter efficiency IP 55
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
61/70 m3/h
115 VAC
50/60 Hz
61/70 m 3/h
24 VDC
DC
61 m 3/h
56/64 m3/h
56/64 m3/h
56 m 3/h
44/52 m3/h
40/46 m3/h
60 Pa
57 Pa
44 dB(A)
44/52 m 3/h
40/46 m3/h
60 Pa
57 Pa
44 dB(A)
44 m 3/h
40 m 3/h
60 Pa
61 Pa
44 dB(A)
15 ... +55 °C -5 ... +55 °C
19/18 W
20/20 W
83 %
83 %
91 %
91 %
40000 h
40000 h
CE, UL, cUL, GOST
-25 ... +55 °C
5W
83 %
91 %
80000 h
Note
145
145
24 VDC
Part no.
125
125
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
145
145
70
5
5
26
01108059 01108060
Air filtered fan FL 200
Air outlet/inlet filter FLA 200
Sheet thicknesses 1 ... 2 mm - cut-out 125 x 125 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 126 x 126 mm
4.24
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Air filtered fans
Air filtered fan FL 225
쮿 Airflow volume 110 m3/h
Air filtered fans
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, with fluted filter IP 55, NEMA type 12
Delivery comprises (completely assembled)
Item
1
Qty
1
2
3
4
1
1
1
01108022
Description
Front grille and case, plastic, ABS, RAL 7035,
self-extinguishing, UL 94 V-0
Filter, filter class G 3 (EN 779)
Fan
Connection AC (terminal block),
DC (spring terminal strip)
Order Information
Description
115 VAC
Part no.
230 VAC
Part no.
Air filtered fan FL 225
60715-147
Air outlet/inlet filter FLA 225
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 225 and FLA 225,
filter class G 3 (EN 779), PU 5 pieces
Fluted filter IP 55 for FL 225 and FLA 225,
filter class G 4 (EN 779), PU 5 pieces
Air outlet/inlet filter FLA 225
Replacement filter IP 54
Fluted filter IP 55
01108019 01108021
01108020
60715-146
60715-158
60715-184
60715-188
Technical data
Voltage
Frequency
Airflow volume with IP 54 filter
(free blowing)
Airflow volume with IP 55 filter
(free blowing)
Combination FL + FLA IP 54
Combination FL + FLA IP 55
Max. static pressure IP 54
Max. static pressure IP 55
Noise level (in accordance with
EN ISO 3741, 50 Hz)
Max. ambient temperature
Power consumption
Filter efficiency IP 54
Filter efficiency IP 55
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
110/125 m3/h
115 VAC
50/60 Hz
110/125 m 3/h
100/110 m3/h
100/110 m 3/h
82/93 m3/h
55/64 m3/h
66 Pa
61 Pa
40 dB(A)
83/92 m 3/h
55/64 m 3/h
66 Pa
61 Pa
40 dB(A)
–15 ... +55 °C
–15 ... +55 °C
19/18 W
20/20 W
88 %
88 %
91 %
91 %
40000 h
40000 h
CE, UL, cUL, GOST
Note
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
01108061 01108062
Air filtered fan FL 225
Air outlet/inlet filter FLA 225
Sheet thicknesses 1 ... 2 mm - cut-out 177 x 177 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 178 x 178 mm
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.25
Climate control – Air filtered fans
Air filtered fan FL 250
쮿 Airflow volume 156 m3/h
Air filtered fans
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, with fluted filter IP 55, NEMA type 12
쮿 Simple to fit without tools by clipping in (can also be bolted)
Delivery comprises (completely assembled)
01108022
Item
1
Qty
1
2
3
4
1
1
1
Description
Front grille and case, plastic, ABS, RAL 7035,
self-extinguishing, UL 94 V-0
Filter, filter class G 3 (EN 779)
Fan
Connection spring terminal strip
Order Information
Description
115 VAC
Part no.
Air filtered fan FL 250
60715-149
Air outlet/inlet filter FLA 250/300
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 250/300 and
FLA 250/300, filter class G 3 (EN 779), PU 5 pieces
Fluted filter IP 55 for FL 250/300 and FLA 250/300,
filter class G 4 (EN 779), PU 5 pieces
Air outlet/inlet filter FLA 250/300
Fluted filter IP 55
01108019 01108021
01108020
223
223
Replacement filter IP 54
60715-148
60715-159
60715-185
60715-189
Technical data
Voltage
Frequency
Airflow volume with IP 54 filter
(free blowing)
Airflow volume with IP 55 filter
(free blowing)
Combination FL + FLA IP 54
Combination FL + FLA IP 55
Max. static pressure IP 54
Max. static pressure IP 55
Noise level (in accordance with
EN ISO 3741, 50 Hz)
Max. ambient temperature
Power consumption
Filter efficiency IP 54
Filter efficiency IP 55
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
156/171 m3/h
115 VAC
50/60 Hz
151/170 m3/h
145/160 m3/h
140/160 m3/h
116/127 m3/h
109/113 m3/h
52 Pa
49 Pa
40 dB(A)
116/127 m3/h
109/113 m3/h
52 Pa
49 Pa
40 dB(A)
–15 ... +55 °C –15 ... +55 °C
18/17 W
18/17 W
88 %
88 %
91 %
91 %
40000 h
40000 h
CE, UL, cUL, GOST
Note
252
252
230 VAC
Part no.
223
223
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
252
252
6
97
6
38
01108063 01108064
Air filtered fan FL 250
Air outlet/inlet filter FLA 250/300
Sheet thicknesses 1 ... 2 mm - cut-out 223 x 223 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 224 x 224 mm
4.26
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Air filtered fans
Air filtered fan FL 300
쮿 Airflow volume 256 m3/h
Air filtered fans
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, with fluted filter IP 55, NEMA type 12
쮿 Simple to fit without tools by clipping in (can also be bolted)
Delivery comprises (completely assembled)
01108024
Item
1
Qty
1
2
3
4
1
1
1
Description
Front grille and case, plastic ABS, RAL 7035,
self-extinguishing, UL 94 V-0
Filter, filter class G 3 (EN 779)
Fan
Connection spring terminal strip
Order Information
Description
115 VAC
Part no.
Air filtered fan FL 300
60715-151
Air outlet/inlet filter FLA 250/300
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 250/300 and
FLA 250/300, filter class G 3 (EN 779), PU 5 pieces
Fluted filter IP 55 for FL 250/300 and FLA 250/300,
filter class G 4 (EN 779), PU 5 pieces
Air outlet/inlet filter FLA 250/300
Fluted filter IP 55
01108019 01108021
01108020
223
223
Replacement filter IP 54
60715-150
60715-159
60715-185
60715-189
Technical data
Voltage
Frequency
Airflow volume with IP 54 filter
(free blowing)
Airflow volume with IP 55 filter
(free blowing)
Combination FL + FLA IP 54
Combination FL + FLA IP 55
Max. static pressure IP 54
Max. static pressure IP 55
Noise level (in accordance with
EN ISO 3741, 50 Hz)
Max. ambient temperature
Power consumption
Filter efficiency IP 54
Filter efficiency IP 55
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
256/292 m3/h
115 VAC
50/60 Hz
256/292 m3/h
233/265 m3/h
233/265 m3/h
231/265 m3/h
180/207 m3/h
116 Pa
112 Pa
42 dB(A)
231/265 m3/h
180/207 m3/h
116 Pa
112 Pa
42 dB(A)
–15 ... +55 °C –15 ... +55 °C
45/39 W
40/40 W
88 %
88 %
91 %
91 %
40000 h
40000 h
CE, UL, cUL, GOST
Note
252
252
230 VAC
Part no.
223
223
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
252
252
6
113
6
38
01108065 01108064
Air filtered fan FL 300
Air outlet/inlet filter FLA 250/350
Sheet thicknesses 1 ... 2 mm - cut-out 223 x 223 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 224 x 224 mm
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.27
Climate control – Air filtered fans
Air filtered fan FL 500
쮿 Airflow volume 480 m3/h
Air filtered fans
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, with fluted filter IP 55, NEMA type 12
쮿 Simple to fit without tools by clipping in (can also be bolted)
Delivery comprises (completely assembled)
01108025
Item
1
Qty
1
2
3
4
1
1
1
Description
Front grille and case, plastic, ABS, RAL 7035,
self-extinguishing UL 94 V-0
Filter, filter class G3 (EN 779)
Fan
Connection spring terminal strip
Order Information
Description
230 VAC
Part no.
115 VAC
Part no.
Air filtered fan FL 500
60715-153
Air outlet/inlet filter FLA 500/600
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 500/600 and
FLA 500/600, filter class G 3 (EN 779), PU 5 pieces
Fluted filter IP 55 for FL 500/600 and FLA 500/600,
filter class G 4 (EN 779), PU 5 pieces
Air outlet/inlet filter FLA 500/600
Fluted filter IP 55
01108019 01108021
01108020
291
291
Replacement filter IP 54
60715-152
60715-160
60715-186
60715-190
Technical data
Voltage
Frequency
Airflow volume with IP 54 filter
(free blowing)
Airflow volume with IP 55 filter
(free blowing)
Combination FL + FLA IP 54
Combination FL + FLA IP 55
Max. static pressure IP 54
Max. static pressure IP 55
Noise level (in accordance with
EN ISO 3741, 50 Hz)
Max. ambient temperature
Power consumption
Filter efficiency IP 54
Filter efficiency IP 55
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
505/505 m3/h
115 VAC
50/60 Hz
505/505 m3/h
480/480 m3/h
480/480 m3/h
380/380 m3/h
370/370 m3/h
76 Pa
74 Pa
54 dB(A)
380/380 m3/h
370/370 m3/h
76 Pa
74 Pa
54 dB(A)
–15 ... +55 °C
–15 ... +55 °C
65/80 W
75/90 W
88 %
88 %
91 %
91 %
40000 h
40000 h
CE, UL, cUL, GOST
320
320
Note
291
291
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
320
320
,5
6,5
150
6,5
5
39,
01108067 01108068
Air filtered fan FL 500/600
Air outlet/inlet filter FLA 500/600
Sheet thicknesses 1 ... 2 mm - cut-out 223 x 223 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 224 x 224 mm
4.28
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Air filtered fans
Air filtered fan FL 600
쮿 Airflow volume 640 m3/h
Air filtered fans
쮿 Converts simply from push to pull operation
쮿 Ingress protection IP 54, with fluted filter IP 55, NEMA type 12
쮿 Simple to fit without tools by clipping in (can also be bolted)
Delivery comprises (completely assembled)
01108025
Item
1
Qty
1
2
3
4
1
1
1
Description
Front grille and case, plastic, ABS, RAL 7035,
self-extinguishing, UL 94 V-0
Filter, filter class G 3 (EN 779)
Fan
Connection spring terminal strip
Order Information
Description
230 VAC
Part no.
115 VAC
Part no.
Air filtered fan FL 600
60715-155
Air outlet/inlet filter FLA 500/600
(items 1 + 2 included), 1 piece
Replacement filter IP 54 for FL 500/600 and
FLA 500/600, filter class G 3 (EN 779), PU 5 pieces
Fluted filter IP 55 for FL 500/600 and FLA 500/600,
filter class G 4 (EN 779), PU 5 pieces
Air outlet/inlet filter FLA 500/600
Fluted filter IP 55
01108019 01108021
01108020
291
291
Replacement filter IP 54
60715-154
60715-160
60715-186
60715-190
Technical data
Voltage
Frequency
Airflow volume with IP 54 filter
(free blowing)
Airflow volume with IP 55 filter
(free blowing)
Combination FL + FLA IP 54
Combination FL + FLA IP 55
Max. static pressure IP 54
Max. static pressure IP 55
Noise level in accordance with
EN ISO 3741, 50 Hz)
Max. ambient temperature
Power consumption
Filter efficiency IP 54
Filter efficiency IP 55
MTBF at 40 °C
Approvals
230 VAC
50/60 Hz
770/785 m3/h
115 VAC
50/60 Hz
770/785 m 3/h
640/653 m3/h
640/653 m 3/h
490/501 m3/h
445/445 m3/h
134 Pa
132 Pa
63 dB(A)
490/501 m 3/h
445/445 m 3/h
134 Pa
132 Pa
63 dB(A)
–15 ... +55 °C
–15 ... +55 °C
115/150 W
110/160 W
88 %
88 %
91 %
91 %
40000 h
40000 h
CE, UL, cUL, GOST
Note
320
320
쮿 Mounting for sheet thicknesses from 1 to 3 mm
쮿 Multiple fan solution on request
쮿 Dimensions, cut-outs and tolerances see user manual
291
291
320
320
,5
6,5
150
6,5
5
39,
01108067 01108068
Air filtered fan FL 500/600
Air outlet/inlet filter FLA 500/600
Sheet thicknesses 1 ... 2 mm - cut-out 223 x 223 mm;
Sheet thicknesses >2 ... 3 mm - cut-out 224 x 224 mm
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.29
Climate control – Accessories
Heaters from 10 W to 150 W
AccessoriesMAIN C ATALO GPart num ber in bold face type: ready for shipping within 2 working daysPart number in norm al type: ready for shipping within 10 working days
쮿 Compact heater without fan
쮿 Simple and fast assembly with clip-on attachment
쮿 Broad range voltage input AC/DC 120 ... 240 V
쮿 Low surface temperature, protective insulation, and
temperature limitation with PTC resistance
Delivery includes (completely assembled)
10 / 20 W
01116002
50 / 100 / 150 W
01116001
Dimension drawing
Item
1
Qty
1
2
1
3
1
Description
Heater element, voltage AC/DC 100 ... 240 V;
PTC resistor, self-regulating
Heating body housing, plastic UL94 V-0; type of fixing:
Clip for 35 mm DIN rail EN 60715
Connection: 2-pin (10 W, 20 W) and/or 4-pin (50 W, 100 W,
150 W) terminal, 2.5 mm², torque 0.8 Nm max.
Order Information
Description
10 W
20 W
50 W
100 W
150 W
Part no.
60715-220
60715-221
60715-222
60715-223
60715-224
Note
10 / 20 W
01116054
50 / 100 / 150 W
01116053
쮿 Thermostat for heating see page 4.65
쮿 Hygrostat see page 4.68
Technical data
Heater output in W
Max. switch-on current in A
Pre-fuse, delay-action in A
Type of protection
Class of protection
Dimensions H × W × D in mm
Weight in kg
Connection
Surface temperature in °C
Test seal
Mounting
4.58
10 W
20 W
50 W
100 W
10
20
50
100
1.0
2.5
2.5
4.5
2.0
4.0
4.0
8.0
IP 20
IP 20
IP 20
IP 20
II
II
II
II
98 × 38 × 75
98 × 38 × 75
110 × 60 × 90
110 × 60 × 90
0.2
0.3
0.3
0.3
2-pin terminal, 2.5 mm², torque 0.8 Nm
4-pin terminal, 2.5 mm², torque 0.8 Nm
< + 80°C, with exception of above mesh surface
CE, UL, VDE, EAC, RoHS
Clip-on attachment for 35 mm DIN rail (EN 60715)
SCHROFF PRODUCT CATALOG E 05/2016
150 W
150
8.0
10.0
IP 20
II
150 × 60 × 90
0.5
ELECTRONICS PROTECTION
Climate control – Accessories
Heaters with heater fans from 150 W to 400 W
Access ori esMAIN CATA LO GPart number in bold face type: ready for shipping wi thin 2 working daysPart number in norm al type: ready for shipping within 10 working days
쮿 Compact heater with fan, small, compact design with high
heater output
쮿 Simple and fast assembly with clip-on attachment or bolt fixing
쮿 Dynamic heating up and temperature limitation by PTC
technology
쮿 Quiet
Delivery includes (completely assembled)
Item
1
Qty
1
2
1
3
4
1
1
01116004
Dimension drawing
Clip attachment
Description
Heater element, voltage 230 VAC, resistor (PTC
resistance) self-regulating
Heating body housing, plastic UL94 V-0; type of fixing:
Clip for 35 mm DIN rail EN 60715
Axial fan, airflow from bottom to top
Connection: 2-pin terminal, 2.5 mm², torque 0.8 Nm max.
Order Information
Description
150 W
250 W
400 W
Part no.
60715-225
60715-226
60715-227
Note
쮿 Thermostat for heating see page 4.65
쮿 Hygrostat see page 4.68
01116050
01116051
Technical data
Heater output in W
Max. switch-on current in A
Pre-fuse, delay-action in A
Axial fan, free blowing output
Type of protection
Class of protection
Dimensions H × W × D in mm
Weight in kg
Surface temperature in °C
150 W
250 W
150
250
9.0
12
10
10
13.8 m²/h
45 m²/h
IP 20
IP 20
II
II
75 × 65× 90
90 × 85 × 111
0.3
0.5
< + 50°C, with exception of above mesh surface
Connection
Test seal
Mounting
2-pin terminal, 2.5 mm², torque 0.8 Nm max.
CE, UL, VDE, EAC, RoHS
Clip-on attachment for 35 mm DIN rail (EN 60715)
SCHROFF.PENTAIR.CO.UK
400 W
400
15
16
45 m²/h
IP 20
II
90 × 85 × 111
0.5
< + 65°C, with exception of above
mesh surface
Part number in bold face type: ready for shipping within 2 working days
Part number in normal type: ready for shipping within 10 working days
4.59
Climate control – Accessories
Heaters from 30 W to 150 W
AccessoriesMain CatalogueP art number in bold fac e type: ready for despatch withi n 2 working daysP art number i n normal type: ready for despatch within 1 0 working days
쮿 Radiator heater (without fan)
쮿 Simple and fast assembly with clip-on attachment and presson terminal connection
쮿 Wide input voltage range 110 ... 250 VAC
쮿 Temperature limiting with PTC resistor
Delivery comprises (completely assembled)
Item
1
Qty
1
2
1
3
1
01102004
Description
Heater element, voltage range 110 ... 250 VAC;
resistor (PTC) self-regulating
Heating body, Al extrusion, anodised
Fixing: clip for 35 mm DIN rail EN 50022
Connection:
type 30, with connecting cable
(3 x 0.5 mm2, 300 mm long, black);
type 45, 100, 150 with press-on terminal connection
(for stranded/rigid wire 3 x 0.5 ... 2.5 mm2)
D
47
W
H
20
39
01113050
Support rail
00508013
Order Information
30
Description
Part no.
Heaters from 30 W to 150 W
60715-020
Support rail DIN rail EN 50022 (35 mm), length 215 mm, 1 piece
45
Part no.
100
Part no.
150
Part no.
60715-021
60715-023
60715-030
20715-001
Technical data
Heater output in W
Surface temperature in °C
Max. switch-on current in A
Type of protection
Class of protection
Dimensions H × W × D in mm
Weight in kg
Test seal
Assembly
30 W
45 W
30
45
approx. 100
approx. 105
3,0
3,5
IP 54
IP 20
I
I
70 × 25 × 50
69 × 70 × 50
0.2
0.3
VDE, CE, UL (File E150057) CE, UL (File E150057)
Clip-on attachment for 35 mm DIN rail (EN 50022)
100 W
100
approx. 130
4.0
IP 20
I
144 × 70 × 50
0.5
CE, UL (File E150057)
150 W
150
approx.140
9,0
IP 20
I
224 × 70 × 50
0.7
CE, UL (File E150057)
Note
쮿 Thermostat for heating see page 4.65
쮿 Hygrostat see page 4.68
4.60
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Accessories
Heater fans 475/550 W
Access ori es
쮿 Heater with fan and thermostat
쮿 Simple and fast assembly with clip-on attachment
쮿 3-pin terminal clamp, separate heater/fan connection
쮿 Thermostat from 0 ... 60 °C
쮿 Temperature limiting with PTC resistor
Delivery comprises (completely assembled)
01108030
Item
1
Qty
1
2
3
4
1
1
1
Description
Plastic housing, polycarbonate
(RAL 9002, grey white),
clip for 35 mm DIN rail EN 50022
Heater element, 230 VAC, resistor (PTC) self-regulating
Thermostat
230 VAC fan
Description
Heater 475 W
Heater 550 W
Support rail DIN rail EN 50022 (35 mm), length 215 mm,
1 piece
165
160
Order Information
Part no.
60715-017
60715-018
20715-001
Technical data
Voltage range
Frequency
Heater output
Air capacity of axial fan
Current at switch-on approx.
Weight
Heater element
Connection
128
124
100
01108069
Thermostat
Control lamp of control
system
Temperature control
Type of protection
Class of protection
Assembly
Dimensions
Support rail
SCHROFF.PENTAIR.CO.UK
230 VAC
50 Hz
60 Hz
50 Hz
60 Hz
475 W
550 W
550 W
650 W
35 m3/h 39 m 3/h 45 m3/h 50 m3/h
11 A
13 A
0.9 kg
1.1 kg
Resistor (PTC), self-regulating
3-pin connecting terminal, 2.5 mm2,
separate connection heating/fan
Adjustment range 0 ... 60 °C
Glow lamp
In the event of fan failure
IP 20
II
Clip-on attachment for 35 mm DIN rail
(EN 50022)
Height 165 mm, width 100 mm,
depth 128 mm
00508013
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.61
Climate control – Accessories
Heater fan 400 W, modular
Accessories
쮿 Modular system consisting of:
heater element, fan, protective grille and connecting cable
쮿 Fan not included in delivery extent; please order fan with
desired air capacity separately
쮿 Simple and fast assembly with clip-on attachment
쮿 Overheating protection through thermal switch
Delivery comprises (completely assembled)
Example of a complete heater unit:
1: heater, 2: fan, 3: protective grille, 4: connection cable
01108007
Item
1
2
3
4
Qty
1
1
1
1
Description
Heater element, high-performance cartridge
Connecting cable fan - heating distributor, length 0.3 m
GND/earth cable, ring tag - open end, length 0.3 m
Clip-on attachment for DIN rail with assembly kit
Order Information
Description
115 VAC
Part no.
Heater fan 400 W, modular
60715-028
Support rail DIN rail EN 50022 (35 mm), length 215 mm,
1 piece
230 VAC
Part no.
60715-029
20715-001
Technical data
Heater element
01108006
Voltage range
Current at switch-on
Heater output
Air capacity m 3/h
Surface temperature with fan
Type of protection
Class of protection
Dimensions:
height x width x depth in mm
Assembly
115 VAC
230 VAC
3.5 A
1.8 A
400 W
Please choose desired fan
Approx. 140 °C
IP 20
I, with GND/earthing
22 x 120 x 160
Clip for 35 mm DIN rail EN 50022
Note
쮿
쮿
쮿
쮿
Support rail
4.62
SCHROFF PRODUCT CATALOG E 05/2016
Attention: Danger of overheating, never use heater without fan
Fan see page 4.63
Thermostat for heating see page 4.65
Hygrostat see page 4.68
00508013
ELECTRONICS PROTECTION
Climate control – Accessories
AC fans for heating 400 W
Access ori es
쮿 The fan is screwed below the heater and the cable is connected
to the heater (please order connecting cable and protective
grille separately)
Delivery comprises
Item
1
Qty
1
Description
Fan (width 119 mm, depth 119 mm)
Order Information
01108005
Connecting cable
Height
Airflow volume
115 V AC
mm
m3/h
Part no.
Type A
25
84
20713-146
Type B
25
108
20713-147
Type C
38
162
20713-244
PVC (2 x 0.75 mm²), 1 m long with 2 Faston connectors
2.8 x 0.5 mm to DIN 46343 T1, 1 piece
Protective grille, metal, to screw-on
230 VAC
Part no.
20713-142
20700-001
20713-243
21101-246
60197-019
Dimensions AC fans
KTA43091
4,7
Type
Frequency in Hz
Airflow volume in m3/h
Noise level per fan in dB(A)
Max. static pressure in Pa
Max. ambient temperature in °C
Power consumption in W
Dimensions: height in mm
(width 119 mm × depth 119 mm)
Type A
50 60
84 90
29 30
23 21
70 70
8
7
25
Type B
50 60
108 120
34 38
41 41
70 70
14 11
25
Type C
50 60
162 192
37 41
73 88
70 70
15 14
38
쮿 Please order connection cable and protective grille separately
104,7
115,0
Note
104,7
115,0
Protective grille
SCHROFF.PENTAIR.CO.UK
1,8
5,5
01108055
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.63
Climate control – Accessories
Speed control for fans
with C13 plug
Accessories
쮿 Suitable for all AC fans and fan units (up to 300 W) with
IEC 60320 C13 plug (plug & play)
쮿 Simple to mount on the support rail provided
쮿 Simple adjustment of switch-on temperature (with knob and
digital display)
쮿 External sensor can be fitted at a desired measurement point
01111001
쮿 Open-collector output (parametrisable)
– Alarm output (active/passive)
– DC fans (PWM output)
– Remote display (via optional digital display with front panel)
Delivery comprises
Speed controller with connecting cables
01111002
Item
1
Qty
1
2
3
4
5
6
1
1
1
1
1
Description
Speed controller; input/output voltages 115 ... 240 V AC,
see Technical Data
Temperature sensor, cable length 1.5 m
Fan cable, 2 m, with IEC 60320 socket
Mains cable, 3 m, with connecting plug
Support rail, St, zinc-plated (EN 50022)
Assembly kit
Order Information
Speed control for fans with C13 plug
Part no.
Mains cable SCHUKO/UTE plug
60715-005
Mains cable IEC 60320 C13 plug
60715-006
Accessories
Thermostat with digital display 230 VAC , 1 piece
Page 4.67
Thermostat with digital display 115 VAC , 1 piece
Page 4.67
Connecting cable for DC fans or alarm output Length 2 m,
60715-007
2-wire (0.34 mm2), 1 piece
01105055
Block diagram
01111050
Speed varies in relation to temperature
Technical data
Voltage range
Frequency
Power consumption
Display
Max. connection power
Max. continuous
current
Adjustment range
Fan speed frequency
Sensor
Sensor connection
In case of sensor failure
Fan connection
Open-collector output
Mains connection
Mechanics
Dimensions
Environmental
conditions
115 ... 240 VAC (90 ... 264 VAC)
48 ... 62 Hz
max. 4 VA
LCD display, height 13 mm, red
300 W (230 VAC), 150 W (115 VAC)
1.3 A
+20 ... +60 °C with potentiometer
25 ... 100 %
External NTC resistor
AMP plug contact and cable, 1.5 m, 2 x 0.22 mm
Max. speed
Cable 2 m with C13 IEC 60320 socket
AMP plug contact, programmable function,
Vmax. 30 VDC, Imax. 30 mA
Cable 3 m with plug
Case, IP 30, plastic, weight 0.5 kg, mounts on
horizontal rail with lip DIN EN 50022
Width 120 mm, height 70 mm, depth 25 mm
0 ... 60°C, max. 85 % rel. humidity,
non-condensing
Note
쮿 Thermostat with digital display, see page 4.67
01111051
4.64
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Accessories
Thermostat with integrated temperature sensor
Access ori es
쮿 To control fans or heaters
쮿 Adjustment range 5 ... 60 °C
쮿 Individual adaptation with three separate components:
thermostat (for cooling or heating), assembly material,
connecting cable (IEC connector or ferrules)
쮿 2 versions
– for heating
– for cooling
Delivery comprises
01108004
3
2
20
Description
40
0
60
50
°C
1
4
01108050
01108009
Adjustment range
Switching
temperature
difference
Sensing element
Contact resistance
Lifespan
Max. switch
performance
Connection
Case
Dimensions
Assembly
Weight
Operating/storage
temperature
Protection class
Connection cable: 2-pin, ferrules - 3-pin, ferrules
SCHROFF.PENTAIR.CO.UK
Part no.
for heating
60715-137
21120-178
62150-201
62150-264
Dimensions
Thermostat
Connection cable: 2-pin, ferrules - IEC socket
Part no.
for cooling
Thermostat with integrated temperature
60715-136
sensor
Accessories
Item 3 DIN rail (EN 50022) 35 mm; length 75 mm;
with fixing materials kit, PU 1 set
Item 4 Connection cable, SCHUKO/UTE connector, cable
length 1.5 m; connection on thermostat/hygrostat, 2-pin,
ferrules; connection on fan IEC socket; 1 piece
Item 4 Connection cable, SCHUKO/UTE connector,
cable length 1.5 m; connection on thermostat/hygrostat,
2-pin, ferrules; connection on fan/heater, 3-pin, ferrules,
1 piece
30
10
1
Description
Thermostat, width 33 mm, height 60 mm, depth 43 mm;
clip-on attachment for 35 mm DIN rail EN 50022,
switched voltage 120 ... 250 VAC
User manual
Order Information
33
43
60
Item Qty
1
1
for cooling
(make contact),
blue control button
0 ... 60 °C
7 K (± 4 K tolerance)
for heating
(break contact),
red control button
Thermobimetal (snap-action contact)
<10 mΩ
>100000 cycles
10 A at 250 VAC, 15 A at 120 VAC;
30 W at DC voltage
2-pin clamp, up to 2.5 mm 2,
torque max. 0.5 Nm
Plastic, in accordance with UL 94 V-0, light grey
Height 60 mm, width 33 mm, depth 43 mm
Clip for 35 mm DIN rail, EN 50022
40 g
-20 ... +80 °C/-45 ... +80 °C
IP 20
01108010
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.65
Climate control – Accessories
Thermostat with integrated temperature sensor
AccessoriesMain CatalogueP art number in bold fac e type: ready for despatch withi n 2 working daysP art number i n normal type: ready for despatch within 1 0 working days
쮿 To control heaters or fans
쮿 Adjustment range 5 ... 60 °C
Delivery comprises
Item Qty
1
1
2
3
4
5
1
1
1
1
Description
Thermostat with clip-on attachment for 35 mm DIN rail
EN 50022, voltage 200 ... 250 VAC and 100 ... 130 VAC
Support rail, length 200 mm
Connection cable, length 1.5 m
Strain relief
Assembly kit for cabinet assembly
Order Information
Description
Thermostat with integrated temperature sensor
01102008
Part no.
20715-002
Technical data
Dimensions
Adjustment range
Switch difference
Supply voltage
Contact load
(ohmic load/inductive load)
Contacts
Type of assembly
Height: 75 mm, width: 75 mm, depth:
25 mm
5 ... 60 °C
0,5 K
200 ... 250 VAC
Heat (terminals 1 - 2) 10 A / 4 A
Cool (terminals 1 - 3) 5 A / 2 A
Changeover contact, single pole
Bolt-on, snap mounting for slide rail
Thermostat with external temperature sensor
Accessories
쮿 To control heaters or fans
쮿 External sensor can be positioned near the critical
sub-assembly
쮿 Adjustment range 20 ... 60 °C, switch difference 3 ... 10 K
Delivery comprises
Item Qty
1
1
2
3
01102007
1
1
Description
Thermostat with external temperature sensor,
sensor length approx. 1.7 m
Mounting plate for cabinet assembly, Al, 2.5 mm
Assembly kit
Order Information
Description
Thermostat with external temperature sensor
Part no.
20715-003
Technical data
Dimension (height x width x depth)
Adjustment range
Switching difference
Mains/line voltage
Contact load (ohmic load/inductive load)
Contacts
Assembly
4.66
SCHROFF PRODUCT CATALOG E 05/2016
93 mm x 68 mm x 44 mm
20 ... 60 °C
3 ... 10 K
90 ... 260 VAC
24 A/10 A
Change-over, single pin
Screw-fixed
ELECTRONICS PROTECTION
Climate control – Accessories
Thermostat with digital display
Access ori es
쮿 Adjustment range from -50 to +100 °C
(switch difference 0 ... 10 °C)
쮿 Display switchable from °C to °F
쮿 Programmable (secured against unauthorised operation)
쮿 3-character red segment display
Order Information
01197001
Front panel 1 U
Description
Thermostat with digital display, 230 VAC
Thermostat with digital display, 115 VAC
Front panel 1 U, RAL 7035 with cut-out for thermostat
Front panel 1 U, anodised with cut-out for thermostat
Front panel 1 U, RAL 7021 with cut-out for thermostat
Part no.
60715-132
60715-133
30118-315
30118-267
30118-360
Technical data
Operating voltage
Power consumption
Dimensions
SZA45550
SCHROFF.PENTAIR.CO.UK
115 VAC or 230 VAC
Approx. 3.5 W
Height: 35 mm, width: 76 mm,
depth: 59 mm
Assembly cut-out
28.8 × 70.5 mm
Adjustment range
–50 ... +100 °C
Switch difference
0 ... 10 K selectable
Data safeguarding at power failure Non-volatile memory
Contact load
8 A/3 A (ohmic/inductive load)
(ohmic load/inductive load)
Input/sensor
PTC resistance,
-55 ... +120 °C, cable length 3 m
Contacts
Relay, changeover contact, single pin
Protection class to front
IP 54
Connection
Screw-on terminals, 2.5 mm2
Fixing
With clamping bracket
Type of assembly
Can be screwed on
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.67
Climate control – Accessories
Hygrostat
AccessoriesMAIN C ATALO GPart num ber in bold face type: ready for shipping within 2 working daysPart number in norm al type: ready for shipping within 10 working days
쮿 Adjustable or fixed relative air humidity
쮿 Switches fan or heaters when the set value is reached
쮿 Visual display
쮿 Integrated LED lights up when the connected consumer is
switched on
쮿 Individual adaptation with three separate components:
Hygrostat, assembly material, connecting cable (input with
SCHUKO/UTE connector; output with IEC connector or open
end) please order separately
01116006
Hygrostat with adjustable and permanently set relative humidity
3
64,5
2
3
4
1
Description
Hygrostat, width 42 mm, height 64.5 mm, depth 38 mm;
clip-on attachment for 35 mm DIN rail EN 50022
User manual
Order Information
rF/
R
65 H
%
1
Item Qty
1
1
2
42
38
Delivery includes (assembled)
5
1
4
01108051
Description
Hygrostat, fixed, 65 % air humidity
Hygrostat, adjustable, 40 ... 90 % air humidity
Accessories
DIN rail (EN 50022) Item 3 35 mm; length 75 mm;
with fixing materials kit, PU 1 set
Connection cable Item 4 SCHUKO/UTE connector, cable
length 1.5 m; connection on thermostat/hygrostat, 2-pin,
ferrules; connection on fan IEC socket; 1 piece
Connection cable Item 4 SCHUKO/UTE connector,
cable length 1.5 m; connection on thermostat/hygrostat,
2-pin, ferrules; connection on fan/heater, 3-pin, ferrules,
1 piece
Part no.
60715-138
60715-213
21120-178
62150-201
62150-264
Technical data
Supply voltage
Default setting for
relative air humidity
Switch difference
01108009
connecting cable, connection cable, 2-pole, ferrule - IEC-(female)
connector; input jack; bush; socket
230 VAC, 50/60 Hz
65 % fixed
40 ... 90% adjustable
5 % air humidity (w 1 % air humidity tolerance
at 25 °C)
Switch contact
Changeover contact (relay)
Lifespan
> 50,000 cycles
Max. switching capacity
8 A (16 A for 10 s)
Mains supply
2-pin terminal, up to 2.5 mm2, torque max. 0.5
Nm
Output change-over relay 3-pin terminal, up to 2.5 mm2, torque max. 0.5
Nm
Case
Plastic, in accordance with UL 94 V-0, light
gray
Dimensions
Height 64.5 mm, width 42 mm, depth 38 mm
Type of assembly
Clip for 35 mm DIN rail, EN 50022
Weight
65 g
Operating/storage
0 ... +60 °C/-20 ... +70 °C
temperature
Max. storage humidity
90 % air humidity (non-condensing)
Type of protection
IP 20
01108010
connecting cable, connection cable, 2-pole, ferrules - ferrules
4.68
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Climate control – Accessories
IEC input plug
Access ori es
쮿 For connection of fans
쮿 Bolted housing made of heat-resistant plastic (UL 94 V-0)
쮿 10 A/250 VAC, protection class I
Order Information
Description
IEC input plug
Part no.
60715-046
KTA45246
SCHROFF.PENTAIR.CO.UK
Part number in bold face type: ready for shipping within 2 working days
Part number in normal type: ready for shipping within 10 working days
4.69
Climate control – Service
Products / cooling concepts
Text
Product
Closed cabinet
Raised cover,
ventilation slots
Perforated doors
19" circulation fan,
top cover fan
Cooling principle
01105060
Description
Type of protection
Noise level approx.
Environmental conditions
Cooling capacity approx. 1)
01105058
01105056
01105057
Natural convection
through thermal radiation
Free convection
through top opening
Free convection
through openings
in doors/rear panels
Cooling with air
≤ IP 55
0
Ti > Ta
< 500 W
≤ IP 20
0
Ti > Ta
500 W ... 800 W
≤ IP 20
55 ... 65 dB(A)
Ti > Ta
500 W ... 6000 W 2)
≤ IP 20
34 ... 67 dB(A)
Ti > Ta
< 2000 W
1) depending on cabinet size, electronic components, location and room cooling concept
2) > 800 W are only possible with own, active cooling through components like servers, etc.
Ti = cabinet inner temperature Ta = cabinet ambient temperature
FloTHERM simulation
ServiceMain Catalogue
Project support from simulation software
FloTHERM simulation software allows to detect hot spots and
problem areas from the concept phase.
Cooling concepts for assemblies through to complete
case/cabinet systems can thus be analysed in advance.
Our FloTHERM experts support you in developing your
concept.
Your advantage:
쮿 Extensive analyses eliminate problems during the concept/
prototype phase
쮿 Short development times
쮿 High performance and reliability for your systems
01103050
4.2
SCHROFF Further information: www.varistar.de E 05/2016
ELECTRONICS PROTECTION
Climate control – Service
Products/cooling concepts
Text
Product
Air filtered fans
Air conditioners
Air/water heat exchanger Air/water heat exchanger
(LHX 3)
(LHX 20/40)
Cooling principle
01102050
Description
Type of protection
Noise level
Environmental conditions
Cooling capacity approx. 1)
01105061
01007055
01005081
Cooling
with
air
Cooling
with
coolant
Cooling
with
water
Cooling
with
water
≤ IP 55
39 ... 71 dB(A)
Ti > Ta
< 1500 W
≥ IP 55
60 ... 81 dB(A)
Ta ≤ 55 °C
< 17000 W
≥ IP 55
45.2 dB(A)
Ta ≤ 70 °C
< 3000 W
≥ IP 55
50 ... 70 dB(A)
Ta ≤ 70 °C
< 40000 W
1) depending on cabinet size, electronic components, location and room cooling concept
Ti = cabinet inner temperature Ta = cabinet ambient temperature
Servic e
Optimal test equipment
Servic eMain CatalogueP art number in bold face type: ready for despatch within 2 working daysPart number i n normal type: ready for despatch within 1 0 working days
Being part of the Pentair group, Schroff and McLean look back on
50 years of experience and are reknown around the world for their
expertise in efficient cooling of industrial facilities and equipment.
Based on our own laboratory test chambers with the most modern
equipement in Europe, America and Asia:
쮿 Walk-in climate chamber to test and optimize completely
integrated cabinets and systems under different conditions
쮿 Smaller climate chambers to test components
쮿 Airflow and air resistance measurements in a wind tunnel
쮿 Noise level measurements
쮿 Tests in accordance with DIN EN 60529 to determine the
type of protection (IP)
Climate bay testing
SCHROFF.PENTAIR.CO.UK
01112001
Outstanding standard products, flexible custom solutions, global
technical support and service add up to a ’cool’ combination!
Part number in bold face type: ready for despatch within 2 working days
Part number in normal type: ready for despatch within 10 working days
4.3
Abkürzungen allgemein
Appendix – Order notes
Packaging units
A packaging unit (PU) - e.g. carton, bag - contains the stated
quantity. If you order the quantity 1, you will automatically receive
the quantity defined as PU.
Example: EMC textile gasket
See page 5.22
Part number 21101-853
Order notesMain C ataloguePart number in bold face type: ready for despatch within 2 worki ng days Part number in norm al type: ready for despatch within 10 working days
Standard
pack quantity (SPQ)
cked
in our warehouse
Please take into consideration that deliveries may be carried out in
the stated SPQs (SPQ, e.g. 5 pieces, 10 pieces, 50 pieces, etc.).
Differing order quantities (e.g. 2 pieces) may be changed to the
next possible delivery quantity = Standard Pack Quantity (in this
case 10 pieces).
Example: Front horizontal rail
See page 5.31
Part number 34560-228
Quantity (per part number): 10 pieces
Quantity (per part number): 1 piece
Standard pack quantity (SPQ): 10 pieces
Order quantity: . . . . . . . . Delivery quantity:
1 . . . . . . . . . . . . . . . . . . . 10 pieces
2 . . . . . . . . . . . . . . . . . . . 20 pieces
3 . . . . . . . . . . . . . . . . . . . 30 pieces
Order quantity:. . . . . . . . . Delivery quantity:
10. . . . . . . . . . . . . . . . 10 pieces
10 20 . . . . . . . . . . . 20 pieces
20 30 . . . . . . . . . . . 30 pieces
Price list
Our price list is available by e-mail from your customer consultant.
Please find all contact details at www.schroff.biz/contact.
Always up-to-date
Please visit our website www.schroff.biz where we continuously
inform about news and technical changes.
Quick links
Catalogue request: www.schroff.biz/catalogues
Delivery times
Part numbers in bold face type are ready for despatch within
2 working days; part numbers in normal type are ready for
despatch within 10 working days.
Business relations
Schroff is exclusively operating in Business to Business
(B2B). Private individuals can buy Schroff products via our
sales representatives (see www.schroff.biz/contact).
Responsible for contents and print
Schroff GmbH, Marketing Communication,
D-75334 Straubenhardt, Germany
Product configurators: www.schroff.biz/conf
Contact details: www.schroff.biz/contact
Product search: www.schroff.biz/oneclick
Front Panel Express: www.frontpanelexpress.eu
VARISTAR: www.varistar.co.uk
The data in this catalogue have been thoroughly edited
and checked - in assistance with an accredited
Quality Management System in accordance with
EN ISO 9001:2008.
Faults and spelling mistakes, but mainly changes due to
improvements and further developments of our products
are subject to change. There is no possibility to claim
indemnity/compensation.
Railway technology: www.schroff.co.uk/railway
IT Infrastructure: www.schroff.co.uk/datacom
12.10
SCHROFF PRODUCT CATALOG E 05/2016
ELECTRONICS PROTECTION
Cabinets
Overview............................................. 1.0
Varistar Cabinet platform.................. 1.2
Varistar Electronics........................... 1.10
Varistar EMC...................................... 1.54
Varistar Seismic................................ 1.84
Varistar MIL....................................... 1.120
Varistar Data/network systems........ 1.124
Varistar Containment........................ 1.202
LHX 20/40 Air/water heat exchangers..... 1.224
LHX 3 Air/water heat exchangers........... 1.236
Novastar............................................. 1.240
Eurorack............................................ 1.270
Outdoor ............................................. 1.316
Etsirack.............................................. 1.346
19” lab racks...................................... 1.354
PROLINE............................................ 1.362
1
2
Wall mounted case
Overview............................................. 2.0
Epcase................................................ 2.36
LAN wall-mounted distributors........ 2.46
Cabinet and
wall-mounted
case accessories
Overview............................................. 3.0
Mechanics.......................................... 3.2
Telescopic slides............................... 3.24
Electrical............................................ 3.29
Monitors, keyboards, monitoring...... 3.44
Socket strips...................................... 3.50
Power control socket strips.............. 3.72
Climate control
Overview............................................. 4.0
Cooling concepts/service.................. 4.2
19” fan trays....................................... 4.4
Air filtered fans.................................. 4.20
Accessories........................................ 4.58
Desktop enclosures
Overview............................................. 5.0
RatiopacPRO...................................... 5.6
PropacPRO........................................ 5.44
CompacPRO...................................... 5.76
Comptec............................................. 5.100
Accessories........................................ 5.108
Interscale........................................... 5.200
Minipac ............................................. 5.230
5
Subracks/
19” chassis
Overview............................................. 6.0
EuropacPRO...................................... 6.2
EuropacPRO
for railroad applications.......................6.70
EuropacPRO industrial applications.. 6.86
EuropacPRO Rugged......................... 6.92
MultipacPRO...................................... 6.112
Inpac.................................................. 6.128
6
Front panels,
Plug-in-units,
Frame type plug-in-units
Overview............................................. 7.0
Front panels....................................... 7.2
Plug-in units...................................... 7.16
Frame type plug-in units................... 7.64
PCB accessories................................ 7.102
Systems
Overview............................................. 8.0
AdvancedTCA..................................... 8.2
AdvancedMC carriers........................ 8.26
MicroTCA............................................ 8.36
AdvancedMC modules....................... 8.56
CompactPCI, Serial, PlusIO, PSB..... 8.68
VME, VME64x, VXS, VPX..................... 8.88
Accessories........................................ 8.106
8
Power supply systems
Overview............................................. 9.0
19” AC/DC switched-mode PSUs..... 9.2
19” AC/DC linear regulators............. 9.12
19” AC/DC convertors....................... 9.15
19” accessories................................. 9.18
PSUs for MicroTCA............................ 9.20
PSUs for VMEbus.............................. 9.22
PSUs for CompactPCI, VME64x.......... 9.24
9
Backplanes
Overview........................................... 10.0
CompactPCI, Serial, PlusIO............ 10.4
PXI.................................................... 10.11
VXS................................................... 10.14
VME64x, VMEbus............................. 10.15
Power............................................... 10.18
Universal.......................................... 10.19
Test adaptors................................... 10.20
10
Connectors,
Front panel component
systems
Overview........................................... 11.0
Connectors...................................... 11.2
Front panel component system...... 11.12
11
Appendix
Standards abbreviations................. 12.0
Notes on ordering............................ 12.10
Order number index........................ 12.11
Product index................................... 12.62
12
3
4
7
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project