Sam4s SPS-2000 Program Reference Manual
Sam4s SPS-2000 is a reliable point-of-sale device designed to meet the demands of retail and hospitality businesses. Its advanced features and capabilities empower users to manage sales, inventory, and customer relationships effectively. With its user-friendly interface and robust construction, the SPS-2000 streamlines operations, enhances efficiency, and provides valuable insights to drive business growth.
Advertisement
Advertisement
SPS-2000
Program Reference Manual
All specifications are subject to change without notice.
2011, CRS, Inc.
PM-SPS-2000 Manual Revision 1.30
CRS, Inc.
Limited Warranty and Disclaimers of Warranty
This manual has been developed by CRS, Inc. It is intended for the use of its customers and service personnel and should be read in its entirety before attempting to install, use or program the product(s).
Nothing contained in this manual shall be deemed to be, and this manual does not constitute, a warranty of, or representation with respect to, the product or any of the products to which this manual applies. This manual is subject to change without notice and CRS, Inc. has no obligation to provide any updates or corrections to this manual. Further, CRS, Inc. also reserves the right, without prior notice, to make changes in equipment design or components as it deems appropriate. No representation is made that this manual is complete or accurate in all respects and CRS, Inc. shall not be liable for any errors or omissions contained in this manual. In no event shall CRS, Inc. be liable for any incidental or consequential damages relating to or arising out of the use of this manual. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied or reproduced without prior written consent of CRS, Inc.
NOTICE
IF ANY WARRANTY IS EXTENDED TO YOU WITH REGARD TO THE PRODUCT(S) TO WHICH THIS MANUAL APPLIES, IT
IS A WARRANTY FROM THE ENTITY OR INDIVIDUAL FROM WHOM YOU DIRECTLY PURCHASED THE PRODUCT(S).
SUBJECT TO THE FOREGOING, UNLESS YOU ARE A DIRECT END USER CUSTOMER OF CRS, INC., CRS, INC. DOES NOT
EXTEND TO YOU ANY EXPRESS WARRANTY OR ANY IMPLIED WARRANTY AND EXPRESSLY DISCLAIMS ANY IMPLIED
WARRANTY OF MERCHANTABILITY, FITNESS FOR USE, OR FITNESS FOR ANY PARTICULAR PURPOSE, OR ANY
WARRANTY OF NON-INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS IN CONNECTION WITH THE PRODUCT(S)
OR ANY SOFTWARE, DRIVERS, OR PROGRAMMING PRODUCT, WHETHER EMBEDDED IN PRODUCT(S) OR PROVIDED AS
A SEPARATE PROGRAM, OR USED IN CONJUNCTION WITH THIS/THESE PRODUCT(S). CRS, INC. SPECIFICALLY DOES
NOT WARRANT THAT THE OPERATION OF ANY DRIVERS, SOFTWARE, OR PROGRAMMING PRODUCTS LICENSED
HEREUNDER, WHETHER EMBEDDED IN PRODUCTS OR PROVIDED AS SEPARATE PROGRAMS, SHALL BE
UNINTERRUPTED OR ERROR FREE OR THAT FUNCTIONS CONTAINED IN SUCH DRIVERS, SOFTWARE OR
PROGRAMMING PRODUCTS SHALL OPERATE IN COMBINATION(S) WHICH MAY BE SELECTED FOR USE BY YOU OR
OTHERWISE MEET YOUR REQUIREMENTS.
CRS, Inc. is not responsible for any damages or loss, either direct, indirect, special, incidental or consequential, which you may experience as a result of your purchase or use of the product(s). Your sole remedy in the event that you encounter any difficulties with the product(s) is against the entity or individual from whom you purchased the product(s).
Revision 2.0 - April 1, 2005
WARNING - U.S.
THIS EQUIPMENT GENERATES, USES AND CAN RADIATE RADIO FREQUENCY ENERGY, AND IF NOT INSTALLED AND USED IN
ACCORDANCE WITH THE INSTRUCTIONS MANUAL, MAY CAUSE INTERFERENCE TO RADIO COMMUNICATIONS. IT HAS BEEN
TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS A COMPUTING DEVICE PURSUANT TO SUBPART J OF
PART 15 OF FCC RULES WHICH ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST SUCH INTERFERENCE
WHEN OPERATED IN A COMMERCIAL ENVIRONMENT. OPERATIONS OF THE EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY
TO CAUSE INTERFERENCE IN WHICH CASE THE USER, AT HIS OWN EXPENSE, WILL BE REQUIRED TO TAKE WHATEVER
MEASURES MAY BE REQUIRED TO CORRECT THE INTERFERENCE.
NOTICE - CANADA
THIS APPARATUS COMPLIES WITH THE CLASS “A” LIMITS FOR RADIO INTERFERENCE AS SPECIFIED IN THE CANADIAN
DEPARTMENT OF COMMUNICATIONS RADIO INTERFERENCE REGULATIONS.
CET APPAREIL EST CONFORME AUX NORMES CLASS “A” D’INTERFERENCE RADIO TEL QUE SPECIFIER PAR MINISTRE
CANADIEN DES COMMUNICATIONS DANS LES REGLEMENTS D’INTERFERENCE RADIO.
ATTENTION
The product that you have purchased may contain a battery that may be recyclable. At the end of its useful life, under various state and local laws, it may be illegal to dispose of the battery into the municipal waste system.
Check with your local solid waste officials for details concerning recycling options or proper disposal
.
Precaution Statements
Follow these safety, servicing and ESD precautions to prevent damage and to protect against potential hazards such as electrical shock.
1-1 Safety Precautions
1. Be sure that all built-in protective devices are replaced. Restore any missing protective shields.
2. When reinstalling the chassis and its assemblies, be sure to restore all protective devices, including nonmetallic control knobs and compartment covers.
3. Make sure there are no cabinet openings through which people - particularly children - might insert fingers and contact dangerous voltages.
Such openings include excessively wide cabinet ventilation slots and improperly fitted covers and drawers.
4. Design Alteration Warning:
Never alter or add to the mechanical or electrical design of the SECR. Unauthorized alterations might create a safety hazard. Also, any design changes or additions will void the manufacturer’s warranty.
5. Components, parts and wiring that appear to have overheated or that are otherwise damaged should be replaced with parts that meet the original specifications. Always determine the cause of damage or over- heating, and correct any potential hazards.
CAUTION
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type recommended by the manufacturer.
Dispose used batteries according to the manufacturer’s instructions.
6. Observe the original lead dress, especially near the following areas : sharp edges, and especially the
AC and high voltage supplies. Always inspect for pinched, out-of-place, or frayed wiring. Do not change the spacing between comp-onents and the printed circuit board. Check the AC power cord for damage. Make sure that leads and components do not touch thermally hot parts.
7. Product Safety Notice:
Some electrical and mechanical parts have special safety-related characteristics which might not be obvious from visual inspection. These safety features and the protection they give might be lost if the replacement component differs from the original - even if the replacement is rated for higher voltage, wattage, etc.
Components that are critical for safety are indicated in the circuit diagram by shading, ( ) or ( ). Use replacement components that have the same ratings, especially for flame resistance and dielectric strength specifications. A replacement part that does not have the same safety characteristics as the original might create shock, fire or other hazards.
ATTENTION ll y a danger d’explosion s’il y a remplacement incorrect de la batterie.
Remplacer uniquement avec une batterie du même type ou d’un type équivalent recommandé par le constructeur.
Mettre au rebut les batteries usagées conformément aux instructions du fabricant.
SAFETY NOTICE :
"For pluggable equipment, the socket-outlet shall be installed near the equipment and shall be easily accessible."
1-2 Servicing Precautions
WARNING: First read the-Safety Precautions-section of this manual. If some unforeseen circumstance creates a conflict between the servicing and safety precautions, always follow the safety precautions.
WARNING: An electrolytic capacitor installed with the wrong polarity might explode.
1. Servicing precautions are printed on the cabinet.
Follow them.
2. Always unplug the units AC power cord from the
AC power source before attempting to:
(a) Remove or reinstall any component or assembly
(b) Disconnect an electrical plug or connector
(c) Connect a test component in parallel with an electrolytic capacitor
3. Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes used. The internal wiring is sometimes clamped to prevent contact with thermally hot components. Reinstall all such elements to their original position.
4. After servicing, always check that the screws, components and wiring have been correctly reinstalled. Make sure that the portion around the serviced part has not been damaged.
5. Check the insulation between the blades of the AC plug and accessible conductive parts (examples
: metal panels and input terminals).
6. Insulation Checking Procedure:
Disconnect the power cord from the AC source and turn the power switch ON. Connect an insulation resistance meter (500V) to the blades of AC plug.
The insulation resistance between each blade of the AC plug and accessible conductive parts (see above) should be greater than 1 megohm.
7. Never defeat any of the B+ voltage interlocks.
Do not apply AC power to the unit (or any of its assemblies) unless all solid-state heat sinks are correctly installed.
8. Always connect an instrument’s ground lead to the instrument chassis ground before connecting the positive lead ; always remove the instrument’s ground lead last.
1-3 Precautions for Electrostatically Sensitive Devices (ESDs)
1. Some semiconductor (solid state) devices are easily damaged by static electricity. Such components are called Electrostatically Sensitive Devices (ESDs); examples include integrated circuits and some fieldeffect transistors. The following techniques will reduce the occurrence of component damage caused by static electricity.
2. Immediately before handling any semiconductor components or assemblies, drain the electrostatic charge from your body by touching a known earth ground. Alternatively, wear a discharging wriststrap device. (Be sure to remove it prior to applying power - this is an electric shock precaution.)
3. After removing an ESD-equipped assembly, place it on a conductive surface such as aluminum foil to prevent accumulation of electrostatic charge.
4. Do not use freon-propelled chemicals. These can generate electrical charges that damage ESDs.
5. Use only a grounded-tip soldering iron when soldering or unsoldering ESDs.
6. Use only an anti-static solder removal device.
Many solder removal devices are not rated as antistatic; these can accumulate sufficient electrical charge to damage ESDs.
7. Do not remove a replacement ESD from its protective package until you are ready to install it.
Most replacement ESDs are packaged with leads that are electrically shorted together by conductive foam, aluminum foil or other conductive materials.
8. Immediately before removing the protective material from the leads of a replacement ESD, touch the protective material to the chassis or circuit assembly into which the device will be installed.
9. Minimize body motions when handling unpackaged replacement ESDs. Motions such as brushing clothes together, or lifting a foot from a carpeted floor can generate enough static electricity to damage an ESD.
Contents
Introduction 9
SAM4s SPS-2000 Overview .....................................................................................................9
Hardware .....................................................................................................................9
Software ......................................................................................................................9
Options ........................................................................................................................9
Unbox & Install MCR .............................................................................................................10
Power Requirements................................................................................................................10
ECR Controls & Connections..................................................................................................11
Front Panel Angle Adjustment ..................................................................................11
Rear Display..............................................................................................................12
SD Memory Card Slot...............................................................................................12
Connection Panel.......................................................................................................13
Default Screen Layout .............................................................................................................14
Screen Saver..............................................................................................................14
Keylinks...................................................................................................................................15
Custom Screen Layouts ...........................................................................................................16
Passwords ................................................................................................................................17
Password Notes .........................................................................................................17
Initialize ...................................................................................................................................17
Memory All Clear....................................................................................................................18
Software Installation & SD Memory Utilities 19
Overview .................................................................................................................................19
Important: Updating Existing Installations...............................................................19
Required Support Resources .....................................................................................20
SPS-2000 Program Components ...............................................................................21
Installing Software Using the TFTP Server Method ...............................................................22
A. Download SPS-2000 Software Files ...................................................................22
B. Set TCP/IP Protocol Options ...............................................................................23
C. Install and Start the TFTP Server ........................................................................25
D. Install the Updated Software ...............................................................................27
E. Verify Software Version ......................................................................................29
Application Upgrade from SD/USB Card ...............................................................................32
Bootloader Upgrade from SD Card .........................................................................................34
O/S Upgrade from SD Card.....................................................................................................35
Capturing SPS-2000 Screens...................................................................................................36
Equipment Required..................................................................................................36
Screen Capture Procedure .........................................................................................36
Image Downloads ....................................................................................................................37
Tips for Getting Images Ready..................................................................................37
Image Download Using SD Memory Card ...............................................................38
Screen Saver Logo ....................................................................................................39
Save/Load End User Programs Using SD Memory Card........................................................40
Save End User Program ............................................................................................40
Restore End User Program ........................................................................................40
Save Reports..............................................................................................................41
Restore Reports .........................................................................................................41
Contents
5
SPS-2000 Program Manual v1.30
6
Contents
S Mode Programming 43
S- Mode Programming Screen.................................................................................................43
Self Tests .................................................................................................................................44
Memory Clearing.....................................................................................................................45
Memory Clear Options ..............................................................................................45
Memory Allocation..................................................................................................................47
Memory Allocation – Definitions..............................................................................47
Key Relocation (V2.xxx).........................................................................................................51
Key Relocation (V3.0 and later) ..............................................................................................53
The PGM Tab ............................................................................................................53
The Design Tab .........................................................................................................53
The Design Tab .........................................................................................................54
The List Tab ..............................................................................................................54
The Select Screen Tab ...............................................................................................55
Function Key Code List.............................................................................................56
Function Key Definitions ..........................................................................................57
Function Key Definitions ..........................................................................................58
System Options ........................................................................................................................65
S-Mode System Options – Definitions......................................................................65
Printer Driver Selections..........................................................................................................68
Printer Driver - Definitions .......................................................................................68
Define Port...............................................................................................................................69
Define Port - Definitions ...........................................................................................69
S-Mode Program Scan Printing ...............................................................................................71
S-Mode Program Scans - Definitions........................................................................71
Password Notes........................................................................................................................72
Load Default Messages............................................................................................................73
Check Unlock/Clerk Unlock....................................................................................................73
SRAM Backup.........................................................................................................................74
Save End User Program.............................................................................................74
Restore End User Program ........................................................................................74
Save Reports..............................................................................................................75
Restore Reports .........................................................................................................75
FTP Transmission......................................................................................................76
P Mode Programming 77
P-Mode Programming Menu ...................................................................................................77
PLU..........................................................................................................................................78
PLU Add & Change ..................................................................................................79
PLU Delete ................................................................................................................82
PLU Status Group .....................................................................................................83
PLU Stock .................................................................................................................87
PLU Minimum Stock.................................................................................................88
Non-PLU Code..........................................................................................................88
Age Verification ........................................................................................................89
PLU Quick Registration ............................................................................................90
PLU Quick Registration ............................................................................................91
PLU Integrity Check..................................................................................................97
PLU Group ..............................................................................................................................98
Function Key ...........................................................................................................................99
Function Key Program Summary ............................................................................100
Function Key Programming Notes ..........................................................................104
System Options ......................................................................................................................108
SPS-2000 Program Manual v1.30
General Function Option Definitions ......................................................................109
Tax Option Definitions............................................................................................114
Cash Drawer Option Definitions.............................................................................115
Training Mode Option Definitions..........................................................................116
Level/Modifier Option Definitions..........................................................................116
Tracking File Option Definitions ............................................................................117
Kitchen Printing/Video Option Definitions.............................................................119
Validation/Subtotal Print Option Definitions..........................................................121
General Printing Option Definitions .......................................................................122
Report Printing Option Definitions .........................................................................125
Report Option Definitions .......................................................................................126
Time Keeping Option Definitions ...........................................................................127
E.J. (Electronic Journal) & Detail Printing Option Definitions ..............................128
Employee ...............................................................................................................................130
Authority Level .......................................................................................................133
Groups By Employee ..............................................................................................134
Employee Card ........................................................................................................134
Reports...................................................................................................................................136
Custom Report.........................................................................................................136
Financial Report/Employee Report .........................................................................137
String Report ...........................................................................................................137
Time.......................................................................................................................................138
Time Period .............................................................................................................138
Time Activated Functions .......................................................................................138
Product & Ingredient .............................................................................................................140
Edit Ingredient.........................................................................................................140
Recipe Table............................................................................................................141
Product Mix Items ...................................................................................................141
Product Mix Group Time Periods ...........................................................................142
Taxes......................................................................................................................................143
Messages................................................................................................................................145
Default Error Messages ...........................................................................................145
Default System Descriptors.....................................................................................148
Message Definitions ................................................................................................149
Printer & KV Routing............................................................................................................154
Promotion Table ....................................................................................................................155
File Management ...................................................................................................................156
P-Mode PGM Scan................................................................................................................ 157
Key Relocation ......................................................................................................................157
Program Guides 159
Delivery System Program Guide ...........................................................................................159
Training Mode Program Guide..............................................................................................159
Table Management Program Guide.......................................................................................160
Table Set Up............................................................................................................160
Alternative Table Shapes/Backgrounds ..................................................................165
Guest Check Tracking Program Guide (Soft Check) ............................................................167
Employee Time Keeping With MCR – Program Guide ........................................................168
Employee Sign On with MCR – Program Guide...................................................................173
Open Check by MCR – Program Guide ................................................................................176
Appendix 179
Report Function Key Report Code Structure.........................................................................179
SPS-2000 Program Manual v1.30 Contents
7
Report # Table .........................................................................................................179
Report Option Table ................................................................................................181
Special Report Commands ......................................................................................182
Glossary of Terms 183
Index 191
Manual Revision Record 194
8
Contents
SPS-2000 Program Manual v1.30
Introduction
SAM4s SPS-2000 Overview
Hardware
The SPS-2000 features a 12.1” color LCD touch screen and many popular off-the-shelf POS peripherals can be connected by way of serial communication ports. The SPS-2000 has no hard disk drive, instead running its built-in application software from on-board flash memory and storing data on non-volatile RAM.
Equipped with an LCD touch screen, the SPS-2000 resembles in appearance and application a PC-based POS terminal. However, unlike open-architecture PC-based terminals, the SPS-2000 cannot run other PC applications – it is only capable of running the bundled, built-in POS application.
Software
The built-in SPS-2000 POS application has considerable flexibility and can be configured for both retail sales and food sales in quick and table service environments.
Like ECR programs, the SPS-2000 application program allows the reseller to configure the terminal to perform in a specific setting. After consulting with the merchant, the reseller uses S-Mode (secure) programs set to memory allocation, system configurations, key functions and locations, port assignments, passwords and other system settings. Then the P-Mode (program) is used to complete the end user program for the merchant with, price look-up (PLU) programs, messages, employees, taxes, and other system options.
Options
Each SPS-2000 ECR is configured with all options included. Each SPS-2000 has maximum memory, a card reader, SD memory card reader, and a rear display standard. No additional ECR options are available.
Introduction
9
SPS-2000 Program Manual v1.30
Unbox & Install MCR
1. Carefully remove the SPS-2000 from the shipping container.
2. Locate and unwrap the magnetic card reader MCR.
3. Remove the two Phillips head screws securing the MCR port cover at the upper-right corner of the screen.
4. Locate the male end of the 7-wire connector at the ECR.
5. Connect the MCR female 7-wire connector to the ECR male 7-wire connector.
6. Carefully tuck the connector and wire into the ECR and attach the MCR with the two threaded screws provided.
Power Requirements
Plug the SPS-2000 into a grounded 3-prong outlet.
The SAM4s SPS-2000 is a modern computerized network system. As with all network systems, it requires appropriate electrical power wiring and proper routing of communication cabling for reliable operation and maximizing the life of the equipment.
When installed in a merchant location, CRS recommends a PowerVar ABC065-11 power conditioner, CRS
P/N 701002, which will support an SPS-2000 ECR and printer. An uninterruptible power supply (UPS) is recommended where frequent power disruptions occur. Without a UPS, the SPS-2000 will shut down and reboot when power is disrupted. (The SPS-2000 reboots in less than one minute.)
CRS also recommends:
1. Dedicated branch circuits for SPS-2000 equipment.
2. Isolated Grounding for all equipment within the SPS-2000 system.
Please refer to the SPS-2000 Installation Guide for detailed power requirements.
10
Introduction
SPS-2000 Program Manual v1.30
ECR Controls & Connections
The Error light will flash during IRC compunctions’
Front Panel Angle Adjustment
SPS-2000 Program Manual v1.30
Standard
Magnetic Card
Reader (MCR)
Front Panel Power Button
Press and hold the Front Panel
Power Button to alternately shut down or activate the touch panel.
Note that the main power switch is located on the bottom of the ECR in the right-rear corner. The front panel power button may be enabled or disabled in the S-Mode options program.
Set the position of the front panel support to adjust the angle of the front panel from 22° to 77°.
Introduction
11
Rear Display
SD Memory Card Slot
Standard Rear Display
12
Introduction
The SPS-2000 SD Memory Card slot can be used to:
Load Application Program Updates
Save/Load End User Program Settings
Load Key Images
Save Screen Captures
SPS-2000 Program Manual v1.30
Connection Panel
Standard ECR ports include:
ECR Power
On/Off
Switch
AC Power Cord
Connection
Serial Number/
Identification
Label
The Standard
Rear Display uses RS-232C
Port #6
Cash Drawer Port (Supports 2-Drawers)
LAN port
Keyboard/Mouse Ports
2-USB Ports
LPT Port (Parallel)
6-RS-232C Comm Ports (2-DB9 Male/4-RJ45)
SPS-2000 Program Manual v1.30 Introduction
13
Default Screen Layout
Mode Tabs
Touch one of the four
Tabs to control the
SPS-2000 Mode:
REG = Registration
REP = Reports
PRG = Program
S = Secure Mode
A password may be required to access to
REG, PRG & S modes.
Main Screen
Forty keys display on the main screen.
Keys can be items/categories
(PLUs) or functions.
A total of 200 different screens
(Keylinks) can be defined to organize items or functions.
Fixed Function Keys
Before version 3.00j, the eight essential function keys are fixed. At
3.00j or later, the eight keys are macros (Macros 33-40) that default to the functions labeled, but can be re-assigned as necessary through macro programming. See the table below for the default assignments:
MACRO33 (function #109)
=
DONE (function #37)
MACRO35 (function #111)
=
PREV. (function #168)
MACRO37 (function #113)
=
SUBTOTAL (function #218)
MACRO39 (function #115)
=
CASH (function #18)
MACRO34 (function #110)
=
PLU (function #167)
MACRO36 (function #112)
=
X/TIME (function #244)
MACRO38 (function #114)
=
CLEAR (function #24)
MACRO40 (function #116)
=
VOID ITEM (function #241)
Screen Saver
A screen saver can be implemented by going to page #5 of P-Mode General Function Options. Depending upon the setting, the screen saver will display after 1 to 99 minutes of inactivity.
When the screen saver is activated, simply touch the screen to restore the normal display.
Message Line:
Displays Error
Messages, Clerk
Identification &
Transaction totals.
Transaction Detail
is displayed here. If over 12 items are registered, a scroll bar displays.
Transaction
Summary Line.
Status Line:
Current Price level, Receipt on/off status & register #.
Fixed Numeric
Keys
The 10-key pad keys are fixed.
They cannot be moved or changed.
14
Introduction
SPS-2000 Program Manual v1.30
Keylinks
The main screen provides 40 programmable locations. In addition to the main screen you can define 199 additional 40-location screens referred to as “Keylinks”. (Note that the default program pre-defines the first
12 keylinks for PLU lists and various function lists.)
In the example depicted below, the PLU List keys and the Payment key open new Keylink Screens.
More about Keylinks
Keylinks have multiple uses. Typically they will be used as menu screens containing like items such as entrees, appetizers or drinks or condiments. They may also be used to organize function keys such as discounts or type of payment keys.
Keylinks can display any combination of PLU keys (menu items or condiments) or function keys such as % keys, media keys, etc.
Keylinks can be opened (displayed) by touching a key on the Main screen or by touching a key on another Keylink. Keylinks can also be opened automatically after the entry of a PLU item (see PLU
Programming).
Keylinks can be programmed to remain open for unlimited entries, with the DONE key used to close the Keylink screen, or can be programmed to close automatically after a set number of entries are completed.
SPS-2000 Program Manual v1.30 Introduction
15
Custom Screen Layouts
Each keylink screen can be designed to contain the variety of item and function keys that you require. Your screens will be designed using the following capabilities:
The Main Screen and each Keylink screen provide 40 single size key locations in a 5 x 8 matrix.
Large, wide and vertical keys may be used and unused locations may be eliminated.
Keys colors can be chosen from an
18-color palate.
Images may be used instead of text for key identification.
Keys may be set to open new screens (keylinks). In this example, the beverage key
(above) is set to open a new screen offering 5-different beverage sizes
16
Introduction
SPS-2000 Program Manual v1.30
Passwords
The correct password is required to access Report Mode, P-Mode and S-Mode. Also, manager controlled activities can be completed only after the correct password is entered.
Password Notes
Default S-Mode and P-Mode Passwords are: 2000; the default Report Mode password is: 0000 (meaning no password entry is required to access this mode); the default manager password is: 9999. You can set your own 4-digit passwords by selecting Passwords in S mode.
Separate passwords for report levels (X and Z1-Z5) can be set in S-Mode System Option #7. Here the default password is also 0000, meaning all report levels can be accessed without password entry.
Authority Level option #40 (found in P-Mode/Employee) allows access to Report Mode, P-Mode and S-
Mode without password entry. Employees (such as managers) linked to an authority level with this option selected, can conveniently access all modes without password entry.
If an employee card system is used, and the MANAGER REQUIRED message displays, employees with manager status can swipe their card to complete the transaction. (Available at version 2.00s)
Initialize
To Initialize the SPS-2000, turn the main power switch off, then on again.
Note: If you initialize while a transaction is in progress, the transaction will be aborted and totals/counters will not be updated.
SPS-2000 Program Manual v1.30 Introduction
17
Memory All Clear
Power OFF the SPS-2000 using the main power switch is located on bottom of SPS-2000 in the right-rear corner.
Hold front power button down.
Turn SPS-2000 main power switch ON while holding down front power button.
Touch [1][2][8][7] for system password.
Touch ALL CLEAR.
Touch YES when prompted “ALL CLEAR THE MACHINE?”
The SPS-2000 will reboot.
Enter the station number after the station reboots: [1] OK.
18
Introduction
SPS-2000 Program Manual v1.30
Software Installation & SD
Memory Utilities
Overview
The latest software revisions will be posted on the SPS-2000 dealer support page of the CRS website: www.crs-usa.com
. Software will be revised continually as anomalies are identified, repaired, and as new features and peripherals are supported.
Always verify that the latest software is installed prior to preparing equipment for installation.
NOTE: Software pre-installed on new equipment may not be the latest version.
Monitor the CRS dealer page and your email for bulletins and software update information.
Verify that the same software version is installed on all terminals in a multi-terminal installation.
Important: Updating Existing Installations
If you are performing an update on an existing installation, remember that you must perform a memory all clear after installing updated software. Before updating an existing installation:
1. Save memory allocation, programs and reports (S/SRAMBACKUP).
2. Perform updates as necessary.
3. Clear all memory from System Menu (power on holding front power button to access System Menu.)
4. Restore previously saved memory allocation, programs and reports (S/SRAMBACKUP). (Note: occasional format changes may prevent reloading of certain programs and/or reports.)
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
19
Required Support Resources
A PC with a network connection and USB port available to download new software.
Equip your support PC with a SD Memory Card reader. The SD card provides the most convenient method of updating the SPS-2000 application software and also can be used for program loading/saving, capturing SPS-2000 screens for documentation purposes and transferring bitmap images to the SPS-2000. (CRS supplies SD cards/readers: P/N 520000 - SanDisk SD 128mb card;
P/N 520001- SanDisk SD 256mb card; P/N 520002 - SanDisk Mobilemate SD+ 5-N-1 card reader/writer.)
NOTE: SD cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
LAN (crossover) cable. CRS Part # 250042
SolarWinds.Net TFTP Server. This is a free program that can be downloaded from the SPS-2000 dealer support page at www.crs-usa.com. With this program running on your support PC connected to an SPS-2000 by LAN, you can access software updates from the SPS-2000. The TFTP Server from SolarWinds will run on any Microsoft Operating System including Windows 95, 98, NT, ME and Windows XP. (TFTP (Trivial File Transfer Protocol) is a simple form of the File Transfer
Protocol (FTP), provides no security features, and is often used by servers to boot diskless workstations.)
Depending upon the method you are using to update the SPS-2000, download the appropriate files from the SPS-2000 dealer support page at www.crs-usa.com
.
20
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
SPS-2000 Program Components
The table below summarizes the two distinct program update methods and requirements for each method.
Update Method
Connection
Updates:
Files Required
Optional Files
Utilities Required
TFTP Server SD Card/USB
LAN None
Application,
MICOM, Boot
Programs, O/S Files zImage app.yaffs
NandBoot.bin
Ramdisk.gz xlib.yaffs
Bootrom.bin
Micom.bin
SolarWinds.Net
TFTP Server
Application Only;
O/S can be updated when
BootROM is
V1.10 or later
Locate O/S files in
“/Update” folder on SD/USB card.
Update Bootrom and Micom only when instructed.
None
Notes
In most cases, the application program will be the only program that will require updating.
1. Application Program – This program will be frequently updated as features and operations are changed. (Do not confuse the application program with the end-user program, which consists of the files and setting prepared for an end user installation.)
2. MICOM – The MICOM is supported by it’s own flash memory. MICOM controls LCD brightness, touch screen, buzzer and MSR. It is anticipated that this program area will remain stable. You will be notified in the case that this program changes.
3. The Boot Area program is executed on power-on. It initializes hardware and loads the OS (Linux) to main memory. It is anticipated that this program area will remain stable. You will be notified in the case that this program changes.
4. KERNAL version v1.10 or later (released 11/04/2008) supports two USB ports and allows screen capture to USB (F10 saves to USB).
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
21
Installing Software Using the TFTP Server Method
This software installation method allows you to update any of the SPS-2000 program areas selectively using a network connection. If you are updating an ECR with BootRom version 1.10 or later, you can forgo use of the TFTP server method and use an SD card or USB memory device to update both applidaton and operating system files.
A. Download SPS-2000 Software Files
Go to the SPS-2000 dealer support page of www.crs-usa.com
and download the zip file for the most current complete software version.
Note: The process used to download and unzip the software files will differ depending upon the operating system and file compression utility used on your PC. One example is shown below. Your procedures should be similar.
1. From the SPS-2000 Support page of www.crs-usa.com
, locate the most current complete version. Right-click on the file, select Open, and then click the Open button on the file dialog box.
2. After the file downloads, open
WinZip and extract the files to a designated folder on your PC.
3. Choose a folder where you wish the extracted files to be located. Make a note of the folder location.
SPS-2000 operating system and application files include: zImage (Linux O/S file)
NandBoot.bin (Booting program in case normal booting fails)
Ramdisk.gz (Linux O/S zip file) xlib.yaffs (Contains font, graphic library, etc.)
22
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
B. Set TCP/IP Protocol Options
At your PC, you must set the network IP Address to:
IP Address 192 . 168 . 0 . 2
Subnet Mask 255 . 255 . 255. 0
Gateway 192 . 168 . 0 . 1
Using the following procedure if you are using Windows XP (other Windows operating systems use similar procedures):
1. Click Start, Settings, Network Connections. The Network Connections dialog displays:
2. Select the Local Area Connection listing and right-click. Select Properties from the sub-menu to display the Local Area Connection Properties dialog box.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
23
3. Select the Internet Protocol TCP/IP listing and click the Properties command button.
CAUTION:
If you are changing your normal network settings to connect to the SPS-2000, be sure to restore your settings after SPS-2000
Communications are complete.
4. Click the “Use the following IP address” option button and enter the settings displayed in the example above.
5. Click OK, and then click OK to close the Local Area Connection Properties dialog box.
24
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
C. Install and Start the TFTP Server
TFTP Server Note: CRS now recommends the tftpd32 server program. Tftpd32 has a smaller footprint and works with all operating systems. (SolarWinds 2003 TFTP Server is an acceptable alternative.)
You must first source and install the TFTP server.
1. Download the “tftpd.32.300.zip” file from the SPS-2000 dealer support page.
2. Extract the tftpd32.exe file from the zip file.
3. Connect the SPS-2000 to the PC using a “crossed network cable” and the LAN port on the SPS-2000.
4. Double click the tftpd32.exe file from the zip file. The server window displays:
5. Click Settings.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
25
6. Click Browse. Browse to the folder that contains the current SPS-2000 software. Click OK.
7. Click the Events viewer tab. From this tab you will monitor the TFTP Server application window when communication is taking place.
NOTE: Do not close the TFTP Server application.
Note the path displays where the program files are located and the IP address displayed is
192.168.0.2
26
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
D. Install the Updated Software
Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner).
Optional: Upgrade the Micom
Micom rarely changes. Update only if specifically instructed to by CRS support.
1. Hold front power button down.
2. Turn SPS-2000 main power switch ON while holding down front power button.
3. Touch [1][2][8][7] for system password.
4. Touch SYSTEM MENU.
5. Touch MICOM DOWNLOAD.
6. Touch YES when prompted “COPY MICOM FILE?”.
7. The ECR display will monitor the progress of the MICOM download (25%, 50%, 75%, 100%).
When successful the TFTP Server window will display “Sent micom.bin to...”.
Optional: Upgrade the BOOT ROM
BOOT ROM rarely changes. Update only if specifically instructed to by CRS support.
1. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner).
2. Hold front power button down.
3. Turn SPS-2000 main power switch ON while holding down front power button.
4. Touch [1][2][8][7] for system password.
5. Touch SYSTEM MENU.
6. Touch BOOT UPDATE.
7. Touch YES when prompted “COPY BOOTLOADER?”.
8. The ECR display will first read: “Downloading BootRom.bin . . .” and then will display location updates until the message “Finished” displays when complete. When successful the TFTP Server window will display “Sent BootRom.bin to...”.
Upgrade the Application Software
1. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner).
2. Hold front power button down.
3. Turn SPS-2000 main power switch ON while holding down front power button.
4. Touch [1][2][8][7] for system password.
5. Touch SYSTEM MENU.
6. Touch COPY ALL.
7. Touch YES when prompted “COPY ALL FOR THE NAND FLASH?”.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
27
8. The ECR display will monitor file downloads. The message “Image writing finished!!” displays when complete. When successful the TFTP Server window will display “Sent . . .” for each file as shown below.
Monitor the TFTP Server screen to review the progress of the file downloads. When data is being transmitted, the message “Sending. . .” displays. When complete, the message “Sent. . .” displays.
Perform an ALL Clear
1. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner).
2. Hold front power button down.
3. Turn SPS-2000 main power switch ON while holding down front power button.
4. Touch [1][2][8][7] for system password.
5. Touch ALL CLEAR.
6. Touch YES when prompted “ALL CLEAR THE MACHINE?”.
7. The SPS-2000 will reboot.
8. Enter the station number after the station reboots: [1] OK.
28
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
E. Verify Software Version
After updating, verify the software version using the following procedures. If your ECR does not update, reboot your PC and repeat the procedure from step A. Verify that you are using a crossover cable to connect the ECR to the PC; do not use a LAN cable.
Application, Kernel & Ramdisk Versions
1. Touch the S Mode tab. Enter the password if required.
2. Touch SELF TEST.
3. Touch VERSION. The Version Screen displays:
Boot Version
1. Turn the Power Switch to the ON position while holding down the power button on the front panel below the screen. The Boot Version displays:
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
29
Current Boot
Version is 1.16
30
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
2. Touch 1 2 8 7.
3. Touch System Menu.
4. Touch Test Etc. The Test screen displays. The Micom Version is displayed on the last line of the screen.
USB
SD CARD
OK SHC SPS-2000 ROK
SMART MEDIA CARD OK
OK
DALLAS KEY
MSR TRACK2
MSR TRACK1/3
CHECK DALLAS KEY
CHECK MSR
CHECK MSR
DRAWER COMPULSORY CLOSED
FRONT SWITCH RELEASED
MICOM VERSION Micom version 1.01c
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
31
Application Upgrade from SD/USB Card
You can update the application software from an SD/USB memory card. (You can only update O/S files from
SD or by the TFTP method.) Beginning at version 3.00G25, you can also backup up the application software.
This function is very useful if the onsite technician needs to duplicate the application software for loading in another terminal.
NOTE: SD/USB cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
1. At your PC, create an “sps2000” folder on SD/USB card. Copy the application image (sps2000) to this folder.
2. Insert SD/USB card into the SPS-2000.
3. From the S-Mode Self Test Menu, touch APPLICATION UPDATE.
4. From the selection window choose Application Update or Application Backup, and then select the memory device: SD or USB. Confirm the update by touching YES.
32
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
5. The screen displays Update or Backup Complete. Click Close.
If you are completing an application backup, there will be a delay of about 3 minutes before the S-
MODE menu returns and the backup is complete. Do not power off the ECR or attempt another operation until the S-Mode menu returns. After completion, it is not necessary to clear memory.
If you are completing application update, you must clear all memory.
6. To Perform an All Clear: a. Power down the SPS-2000 (the main power switch is located on bottom of
SPS-2000 in the right-rear corner). b. Hold front power button down. c. Turn SPS-2000 main power switch ON while holding down front power button. d. Touch [1][2][8][7] for system password. e. Touch ALL CLEAR. f. Touch YES when prompted “ALL CLEAR THE MACHINE?”. g. The SPS-2000 will reboot. h. Enter the station number after the station reboots: [1] OK.
7. Verify the Application software version by pressing the X/TIME key in REG mode. The version information will display.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
33
Bootloader Upgrade from SD Card
Beginning at BootROM version 1.10, both bootloader and operating system files can be updated from the SD card (not USB). Updates to ECRs with BootROM versions before version 1.10 must be done using the TFTP server method.
NOTE: SD cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
1. Go to the SPS-2000 dealer support page of www.crs-usa.com
and download the zip file for the most current complete software version. Unzip and locate the BootRom.bin file.
2. At your PC, create an “Update” folder on the root of the SD card. Copy the BootRom.bin file to this folder. In Windows Explorer, your view should look similar to this:
3. Insert the SD card into the SPS-2000.
4. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner).
5. Hold front power button down.
6. Turn SPS-2000 main power switch ON while holding down front power button.
7. Touch [1][2][8][7] for system password.
8. Touch SYSTEM MENU.
9. Touch BOOT UPDATE - SD.
10. After updating is complete, turn the SPS-2000 power off.
11. Perform an All Clear a. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner). b. Hold front power button down. c. Turn SPS-2000 main power switch ON while holding down front power button. d. Touch [1][2][8][7] for system password. e. Touch ALL CLEAR. f. Touch YES when prompted “ALL CLEAR THE MACHINE?”. g. The SPS-2000 will reboot. h. Enter the station number after the station reboots: [1] OK.
34
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
O/S Upgrade from SD Card
Beginning at BootROM version 1.10, both bootloader and operating system files can be updated from the SD card (not USB). Updates to ECRs with BootROM versions before version 1.10 must be done using the TFTP server method.
NOTE: SD cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
1. Go to the SPS-2000 dealer support page of www.crs-usa.com
and download the zip file for the most current complete software version. Unzip and locate the NandBoot.bin, zImage, ramdisk.gz, xlib.yaffs, and app.yaffs files.
2. At your PC, create an “Update” folder on the root of the SD card. Copy the NandBoot.bin, zImage, ramdisk.gz, xlib.yaffs, and app.yaffs files to this folder. In Windows Explorer, your view should look similar to this:
3. Insert the SD card into the SPS-2000.
4. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner).
5. Hold front power button down.
6. Turn SPS-2000 main power switch ON while holding down front power button.
7. Touch [1][2][8][7] for system password.
8. Touch SYSTEM MENU.
9. Touch Copy All - SD.
10. After updating is complete, turn the SPS-2000 power off.
11. Perform an All Clear: a. Power down the SPS-2000 (the main power switch is located on bottom of SPS-2000 in the right-rear corner). b. Hold front power button down. c. Turn SPS-2000 main power switch ON while holding down front power button. d. Touch [1][2][8][7] for system password. e. Touch ALL CLEAR. f. Touch YES when prompted “ALL CLEAR THE MACHINE?”. g. The SPS-2000 will reboot. h. Enter the station number after the station reboots: [1] OK.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
35
Capturing SPS-2000 Screens
Equipment Required
SPS-2000 Terminal
PS/2 Keyboard
SD Memory Card
NOTE: SD cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
SD Memory Card Reader
Screen Capture Procedure
1. Set S Mode System Option-General Function Option #14 “Silent Key Depression” to NO.
2. Power down SPS-2000.
3. Connect a PS/2 Keyboard to the appropriate port.
4. Power up SPS-2000.
5. Insert a SD Memory Card into the SD slot on the right-front of the terminal.
6. Navigate to the screen you wish to capture.
7. Press and hold the F5 key on the keyboard until the audible “beep” is heard. After a delay that may last several seconds, the screen capture confirmation dialog box momentarily displays and closes. Do not proceed until the confirmation displays.
8. If you wish to capture multiple screens, press and hold F5 for each screen you wish to capture. Be sure to wait until the confirmation dialog displays before attempting another screen capture or operation.
9. When you have completed screen captures and wish to save them to the SD memory card, press and hold the F9 key (press and hold F10 to save to USB with KERNEL v 1.10 or later) on the keyboard until the audible “beep” is heard. The copy dialog box momentarily displays and closes. All captured screens are copied to the sps2000capture folder on the memory card. (If you are saving screen captures to the SD card for the first time, the SPS-2000 will create the sps2000capture folder automatically.) After captures are copied to the SD card, press F7 on the keyboard to erase the captures from the ECR memory.
Screens are automatically saved in the .png image format and named using the following convention:
20051120054251.png
Year
Date 6-digit time of capture: HHMMSS
10. Remove the SD Memory Card from the SPS-2000 terminal and insert the card into the SD Card
Reader at the PC. You can copy the captured screens to your hard drive, or insert them as needed into
Microsoft Word documents.
36
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
Image Downloads
Key images can be added to function and PLU keys. (Images can also be used for keyscreen backgrounds
(viewed in REG mode where key locations are inactive.) Background Image display requires software version 2.00x or later.) Images add style and usability to the SPS-2000 touch screen.
This procedure allows you to download images to the SPS-2000 where they can be added to keys in the S-
Mode Key Location program.
Tips for Getting Images Ready
The maximum image size for 1 x 1 size keys is 60 x 50 pixels. (2 x 2 size keys can be up to 120 x
100 pixels; 1 x 2 size keys can be 120 x 50 pixels; 2 x 1 size keys can be 60 x 100 pixels.) You will need to use a graphic program such as Microsoft Paint to re-size larger images.
Images in many common formats can be used: i.e. .gif, .tif, .jpeg, .bmp. (.wmf format images cannot be used.)
The length of the image file name must be less than 12-characters.
The image size for background images is 320 x 425 (this size will fill the entire panel). The background image file name(s) should be “flist_imgxxx.jpg”, where xxx means the keylink number,
001 through 200. The extension must be .jpg (with lower case). To display the background image, you must also set the DISPLAY BACKGROUND IMAGE option to YES. View this option by touching the PGM button from the KEY RELOCATION screen.
A large selection of clip art can be accessed without charge from Microsoft Office Online at http://office.microsoft.com/clipart/default.aspx?lc=en-us .
CRS is preparing a library of common key images for use on the SPS-2000. Go to the SPS-2000 product page of the dealer area of www.crs-usa.com
to access these images.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
37
Image Download Using SD Memory Card
1. At your PC, create a folder “image” on the SD memory card and copy the images you wish to transfer into this folder.
2. Insert the SD Memory Card into the SD slot on the right-front of the SPS-2000.
3. Select Key Relocation from the S-Mode main menu.
4. Open the Button Image Select screen by touching the key next to the “Button Image Select” label. (It does not matter which button is selected.)
5. Touch COPY. At the confirmation dialog, touch YES.
Touch Here
Buttons with
“X” button type do not display on the
Keylink screen
38
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
6. After successful transfer, the new images will display. Note that when the image file exceeds 10 images, additional image pages are used. Touch the PAGE UP/PAGE DN keys to view all available images.
7. Click OK to close the Button Image Select dialog.
Screen Saver Logo
When the screen saver is engaged, the default SAM4s logo moves in a pattern across the screen. This logo can be replaced with a custom logo. Name the custom logo “logo.jpg”. The maximum logo size is 600
(wide) X 400 (height)
.
(logo.jpg works best if under 100K in size.)
Beginning with software version 2.01n, a second screen saver option is available. Set SYSTEM
OPTION/GENERAL FUNCTION OPTION #58 to ROTATING to allow up to fifty images to sequence on the screen. These images must be named “logo##.jpg” where ## is 01 through 50.
Follow these steps to implement a custom logo.
1. Make a logo.jpg file (or logo##.jpg files).
NOTE: file must be lower case “logo.jpg” not “LOGO.jpg”
2. Make a folder on the SD card named \image. (This is the same folder that is used to contain key images.)
3. Copy the logo files to this directory.
4. Move the SD card to the SPS-2000.
5. From the SPS-2000 S Mode menu, choose Key Relocation, then Image, then Copy and confirm.
6. The new image(s) will replace the SAM4s logo as the screen saver.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
39
Save/Load End User Programs Using SD Memory Card
Save End User Program
1. From the S Mode menu touch SRAM Backup.
2. Select the backup method, SD, USB, or FTP.
3. Depending upon the method selected, Insert a SD card in the SPS-2000; or insert a USB memory device, or connect the SPS-2000 to the FTP site via a router and internet connection.
NOTE: SD cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
NOTE: This action will backup the SPS-2000 end user program in the path:
SPS2000/backup/xxxxxx, where xxxxxx is the store number set in S-Mode system options. When you restore programs, SPS-2000 will look for program data for the store number set in system options. If you had previously saved a program for the same store on the same device, the backup function will write over your previous end user program. Be sure to archive previously saved programs to your PC.
4. Touch BACKUP PGM TO SD from the SRAM Backup menu.
5. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the download is complete.
Restore End User Program
1. Verify that the store number set in S-Mode System Options matches the store number folder where the program you wish to restore is stored. Programs are stored on the SD card or USB memory at
SPS2000/backup/xxxxxx, where xxxxxx is the store number set in S-Mode system options.
2. Insert the memory device containing the program in the SPS-2000.
3. Go to S Mode and touch SRAM Backup.
4. You must first restore the program’s memory allocation.
Touch LOAD MEMORY ALLOCATION FROM SD.
40
Software Installation & SD Memory Utilities
SPS-2000 Program Manual v1.30
5. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the upload is complete.
6. Close the SRAM Backup screen, then touch Memory Clear. Touch 13. CLEAR PLU FILE. Even if just the default program is loaded, PLUs must be cleared before restoring the program. Close the
Memory Clear Screen
7. Touch SRAM Backup, and then touch RESTORE PGM FROM SD.
8. From the selection dialog, select the individual program you with to restore or select “All” to restore all programs.
Note: At version 2.02n, “ETC” restores: NON PLU, TARE WEIGHT, AGE VERIFICATION, and TABLE
DISPLAY.
9. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the upload is complete.
Save Reports
(Note that the Report Save/Restore feature requires V2.00d software or later.)
Reports can be saved to an SD card, USB memory stick or to an FTP site. All reports are saved simultaneously. Each report is saved in .rpt format. A report viewer utility is available so that the file data is available to Excel or other PC applications. Reports are stored at the following path:
sps2000/backup/xxxxxx/REP_mmddyyyy
Where “xxxxxx” represents the 6-digit numeric store number and “mmddyyyy” represents the date the reports were saved. Multiple stores and multiple report dates can be stored on the device.
1. From the S Mode menu touch SRAM BACKUP and select a backup method, SD, USB or FTP.
2. Depending upon the method selected, Insert a SD card in the SPS-2000; or insert a USB memory device, or connect the SPS-2000 to the FTP site via a router and internet connection.
3. Touch SAVE REPORT TO SD
4. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the download is complete.
Restore Reports
(Note that the Report Save/Restore feature requires V2.00d software or later.)
Previously saved reports can be restored to the memory of the SPS-2000. Report saving is advised whenever service activity or updates are required on installed ECRs. In case of memory clearing, customer totals can be restored without disrupting store security or accounting.
1. From the S Mode menu touch SRAM BACKUP and select a backup method, SD, USB or FTP.
2. Depending upon the method selected, Insert a SD card in the SPS-2000; or insert a USB memory device, or connect the SPS-2000 to the FTP site via a router and internet connection.
3. Touch RESTORE REPORT FROM SD.
4. At the selection window, touch the date of the report(s) you wish to restore.
5. Touch OK. The PLEASE WAIT message displays until the upload is complete.
SPS-2000 Program Manual v1.30 Software Installation & SD Memory Utilities
41
S Mode Programming
S- Mode Programming Screen
CAUTION:
S-Mode functions are reserved for dealers who set-up and service your SPS-2000 system. The user will not normally perform S-Mode functions.
The procedures described in this area are security sensitive. Many S-Mode functions, including memory clearing and memory allocation, may cause damage or loss if they are performed without first backing up register data.
► From the Main Screen, touch the S tab. Enter the S-Mode Password and touch OK to view the S-Mode screen.
S Mode Programming
43
SPS-2000 Program Manual v1.30
Self Tests
The following procedures are used to perform diagnostic tests on the ECR. The integrity of peripherals is tested at this stage.
► Touch SELF TEST from the S mode MAIN MENU to display the H/W TEST Screen.
Self Tests - Definitions.
SERIAL & IRC LOOP BACK
This is a diagnostics test for the serial port. Special Loop back connections are required.
DRAWER
This will test the opening of the cash drawers - there are 3 drawers available.
LCD
This will test the integrity of the display.
TOUCH
This will test the touch panel.
RTC SETTING
This is the real time clock setting for the service mode.
RAM
This will test both reading and writing of the Random access memory. NOTE: This test is nondestructive. Performing this test will not affect the current program or totals.
IRC
This will test the Ethernet inter-register communication, helping to determine that all ECRs are connected.
Register # Setting – This re-programs the ECR’s register number.
IRC System - This tests the Inter Register communications network.
PRINTER
This will test any device connected to each of the seven output ports
CONTRAST
You can adjust the display contrast.
MSR
This will test attached MSR.
DALLAS KEY
The dallas key option is not available on this model.
VERSION CHECK
This will check and display the current operating version.
SD/USB TEST
This will test SD card or USB stick.
FINGERPRINTS
This will test attached MSR.
44
S Mode Programming
SPS-2000 Program Manual v1.30
NETWORK PING TEST (v3.00y Feb. 27, 2009 or later)
This will test a specified network IP address.
AGING TEST
APPLICATION UPDATE
Touch APPLICATION UPDATE to initiate an update of the application program by SD card. The update application file SPS2000 must reside in the SPS2000 folder on the card. See Application Upgrade from SD/USB Card” on page 32 for details
Memory Clearing
The Memory Clear selection allows you to selectively clear various areas of the SPS-2000 memory.
► Touch MEMORY CLEAR from the S MODE MAIN MENU to display the S mode MEMORY CLEAR
Screen.
Memory Clear Options
(1) RESET ALL TTLS, CNTS & GRAND TTLS
This will remove any sales from the reporting memory, clearing all totals, including grand totals.
(2) CLEAR TOTALS AND COUNTERS
This will clear all sales totals from the reporting memory, excluding grand totals.
(3) CLEAR GRAND TOTALS ONLY
This will clear grand totals only, excluding all other sales totals.
(4-7) CLEAR ORDER TRACKING 1 - 4
This will clear the open checks, setting the balance to zero. The PLU sales are still retained for that check on the financial and product reports. This must be done on the ECR set by S-mode options.
(8) CLEAR PAID RECALL
This is reset the memory for displaying paid transactions, the information will begin storing again.
(9) CLEAR PRODUCT PROJECTIONS
This will reset any information held in the product mix, sales projection files, which store the product usage, period projection analysis.
(10) CLEAR TIME-KEEPING
This will reset employee time clock information, remove all hours worked totalizers and labor costing.
(11) CLEAR CLERK INTERRUPT
This will remove any sales currently open against an employee.
(12) CLEAR PRE-POLL STATUS FLAG
If an unsuccessful attempt has been made to consolidate ECRs sales data, the report is flagged as failed.
This will remove that flag allowing normal reporting consolidation again.
(13) CLEAR PLU FILE
SPS-2000 Program Manual v1.30 S Mode Programming
45
This will remove all programmed PLUs from the file, leaving on the basic program.
(14) CLEAR ELECTRONIC JOURNAL
This will reset all sales data held within the electronic journal without printing.
(15) CLEAR CONSECUTIVE#
This will reset the receipt consecutive number.
CLEAR ALL 1-11
This will clear all sales totals as shown above in options 1–11.
CLEAR BATCH
This will clear the current integrated payment batch.
CLEAR GLOBAL ORDER #
This will reset the global order number to zero.
CLEAR DELIVERY
Clears all deliver files. Requires v3.00a or later.
46
S Mode Programming
SPS-2000 Program Manual v1.30
Memory Allocation
CAUTION: The procedures described in this area are security sensitive. Memory is automatically cleared after memory allocation is set. Do not change memory allocation after your system has been installed unless you are aware that all programs, totals and counters will be cleared. Do not share this information with unauthorized users and provide the S-Mode password only to those you may want to perform these functions.
The Memory allocation is requested when the machine is program reset and default memory allocation is declined. The information can be displayed at any time by selecting S mode option memory allocation.
► From the S mode MAIN MENU touch MEMORY ALLOCATION to display the S mode MEMORY
ALLOCATION Screen.
Options are organized under six tabs. Available memory is monitored at the top of the screen. An error message displays if you attempt to allocate features that require more memory than is available.
Memory Allocation – Definitions
The following entries define the file sizes for the ECR; once they have been entered they are fixed and cannot be changed without program resetting the machine. All ECRs within an IRC (inter register communications) system should have identical memory allocations.
(1) # OF PLU
This is the maximum number of PLUs (Price Look-Ups).
(2) # OF PLU STATUS GROUPS
This is the maximum number of Status Groups. These are used to program common system flags to a group of PLUs and are required by the system.
(3) # OF PRICE LEVEL PER PLU (1 - 5)
This is the number of price levels per PLU. Each product has the ability to use five prices selected from twenty price bands. If you wish to use price levels, you must determine the number of price levels here.
If Price levels are set, they are set for all PLUs.
(4) PLU REPORT BY PRICE LEVEL
If selected, the PLU report will detail sales at each level, rather than a total and counter for sales at all levels combined.
(5) # OF EMPLOYEES
Determine the total number of employees and set the maximum use wish to use here. Employees include all who use the register for any purpose, including those using only the time clock feature for clocking in/out.
(6) # OF TIME ENTRIES PER EMPLOYEE
Determine the total number of employees and set the maximum use wish to use here. Employees include all who use the register for any purpose, including those using only the time clock feature for clocking in/out.
SPS-2000 Program Manual v1.30 S Mode Programming
47
(7) USE GROUP BY EMPLOYEE
Determine if you wish to report GROUPS by EMPLOYEE. If you choose Yes, then you can report up to
30 of the 99 groups for each employee. See "Groups By Employee" on page 134 to select which groups will report for each employee.
(8) CHECK TRACKING METHOD
Choose HARD or SOFT. Hard checks store only the check balances; soft check store check detail for the number of lines determined at step 12.
(9) # OF TRACKING FILES
The norm is to have one tracking file for check tracking memory. This however can be increased to four, each running independently, thus allowing separate tracking for multiple drive-thru lanes, phone-in orders, etc.
There is the additional option of providing a history for closed soft checks. Tracking file 2 will store closed checks for tracking file one and tracking file 4 will store 3. Normal tracking with not take place on files 3 and 4 when they are allocated to store history.
(10) # OF LINES PER TRANSACTION
Determine how many lines of receipt print can be buffered for each transaction. If this number is reached during a transaction, the message "BUFFER FULL" will display and the transaction must be finalized.
Note: Must be greater than or equal to the number of lines per soft check. Note that voided items also use lines in a check. (At version 2.00s, the maximum was increased to 1100.)
(11) # OF LINES PER CHECK/INTERRUPT
This is the maximum number of product lines that can be stored per check, also when using clerk interrupt this is the number of lines that can be stored per clerk. This field also controls the number of history lines that can be stored for closed check tracking files before wrap round reporting begins. (At version 2.00s, the maximum was increased to 1100.)
(12) MAXIMUM NUMBER OF CHECKS
Determine the maximum number of checks for each tracking file.
(13) # OF TIME PERIODS
This is the number of time periods by which information will be analyzed. This can be either 24-hourly,
48 - 1/2 hourly, 96 - 15 minutes. Further programming allows suppression and edit of any time report within the chosen range
(14) # OF PRODUCT MIX GROUPS
Product Mix Groups can be used to implement a simplified ingredient system for tracking only essential ingredients associated with items (i.e. cups for beverages or number of pieces for chicken menus.) Enter the number of Product Mix items you wish to track here.
(15) # OF PRODUCT MIX TIME PERIODS
Product mix groups report usage by time period. Determine the number of periods you wish for product mix time reporting. The actual time for each period can be customized. .
48
S Mode Programming
SPS-2000 Program Manual v1.30
(16) PROJECTIONS
The Product Projection report provides a history of each product mix item's sales by day of week.
(17) # OF RECIPE
Recipes can be used for stock control. When a product is sold; the information will be automatically calculated back through the recipe file in order to deduct the stock from the relevant ingredients. This is the maximum recipes available
(18) # OF INVENTORY INGREDIENT
Enter the maximum number of inventory ingredients you wish to use if you are implementing an ingredient inventory system.
(19) # OF LINES FOR ELECTRONIC JOURNAL
This is the maximum number of lines available for the journal storage area before a reset report is required. One line is required for each line of normal print. Wrap round reporting can be activated with line-by-line override of the oldest data.
Note: Receipt Reprint (available at version 2.00s) requires that the transaction to be retrieved be resident in the electronic journal. Be sure to allocate electronic journal if you wish to use the receipt reprint options.
(20) # OF PAID RECALL TRANSACTIONS
Enter the number of preceding transactions (a maximum of 99) that may be viewed by repeatedly pressing the PAID RECALL key.
(21) CLERK INTERRUPT
This enables the suspension of an active sales transaction, enabling more than one operator to use the
ECR at a time.
(22) EAT-IN BY TIME PERIODS
This allows analysis eat-in sales by time period.
(23) TAKE OUT BY TIME PERIODS
This allows analysis eat-in sales by time period.
(24) DRIVE THRU BY TIME PERIODS
This allows analysis eat-in sales by time period.
(25-28) TRACK 1 – 4 BY TIME PERIODS
This provides analysis of the closed/paid check tracking totals with the total monies received reported per hour.
(29) REPORT SELECTION TABLE
Z2 represents accumulation of Z1 reports; Z3 represents accumulation of Z2 reports, etc. You must select all levels below your highest selected report level. For example, if you select Z4 reporting for a particular report, then you must also select Z1, Z2, and Z3 for that report. Each of the five report areas can be read and reset independently.
(30) # OF PROMOTION TABLE
This option represents the promotion (mix & match, fixed price, or multi buy) tables that will be available.
SPS-2000 Program Manual v1.30 S Mode Programming
49
(31) # OF ITEMS FOR PROMOTION TABLE (99)
If fixed price or multi buy promotions are used, specific lists of items are maintained that must be sold to allow the discount or new price. This option determines the maximum number of items that can be listed.
(32) BITMAP NV BUFFER (0-999999)
Not Used.
(33) DELIVERY TABLE
The number of customer records maintained in the delivery system. Each record includes Title, First
Name, Last Name, Address 1/Address 2, City, ZIP, telephone, email, and birthday fields.
50
S Mode Programming
SPS-2000 Program Manual v1.30
Key Relocation (V2.xxx)
NOTE:
► From the S mode MAIN MENU touch KEY RELOCATON to display the S mode KEY RELOCATON
Screen.
Note: Key Relocation functions shown here are also available in PGM mode.
The main screen provides 40 programmable locations. In addition to the main screen you can define 200 additional 40-location screens referred to as “Key Links”. (Note that the default program pre-defines the first
12 keylinks for PLU lists and various function lists.) Use this program to set function locations on each Key
Link.
Use these keys to select the
Main Screen or any of the
200 Key Links
Touch here to set Key Link options, i.e. # of choices, exit with DONE key, etc.
Select one of 4 font sizes
Touch KEY to select the key function. Touch IMAGE to display a key image
Touch Copy to copy the keys on this screen to a range of other screens
Touch KEY to place this key on all or selected Key
Links. Touch SHAPE to place this key shape on all or selected Key Links
Select black or white font color.
Touch a button color to select a different color.
Touch here to select a button size/type.
Inactive buttons (“X”) do not display in REG mode.
Beginning with version 2.01m, you can program a key descriptor that is independent of the PLU descriptor. (If the key descriptor is formatted or abbreviated to fit the key location, the result may not always look pleasing when printed on the receipt or guest check.)
SPS-2000 Program Manual v1.30 S Mode Programming
51
About Keylinks
Keylinks have multiple uses. Typically they will be used a menu screens containing like items such as entrees, appetizers or drinks or condiments. They may also be used to organize function keys such as discounts or type of payment keys.
Keylinks can display any combination of PLU keys (menu items or condiments) or function keys (% keys, media keys, etc.)
A KEYLINK can be opened (displayed) by touching a key on the Main screen or by touching a key on another Key Link. Key Links can also be opened automatically after the entry of a PLU item (see
PLU Programming). If desired a specific Key Link can display after employee sign on is completed.
KEYLINKs can be programmed to remain open for unlimited entries, with the DONE key used to close the KEYLINK screen, or can be programmed to close automatically after a set number of entries are completed.
Setting Keylink Options
1. Select KEY RELOCATION from the S or P main menu.
2. Use the ▼ or ▲ keys to select the keylink screen you wish to program, or touch the button indicating the keylink currently displayed and enter the number of the keylink you wish to program.
3. Touch the PGM button to display the options. Note that options are not available for the main screen
(keylink #0), you must select keylink #001 to #200 to set options.
The keylink set here will display after entries for the initial keylink are satisfied or the keylink is exited.
The current keylink is displayed here.
Touch this button to select another
Touch the PGM button to open the option window.
If YES, the keylink will ask for the quantity of items.
Touch OK to exit and save the options for this keylink.
The DISPLAY
BACKGROUND
IMAGE option is available at version
2.01b or later.
Note that you must also download the image. See “Image
Downloads” on page 33.
The value entered in the “number of choice” field will determine the number of entries before the keylink is automatically closed. For example, if “2” is set here, after 2 entries, the keylink will automatically close.
•
If the DONE key is enabled and you set “0” here, unlimited keylink entries will be accepted. When the DONE key is pressed, the previous keylink will display.
•
If the DONE key is enabled and you wish to advance to the keylink set in the “FUNCTION LIST KEY LINK” field, set the “NUMBER OF CHOICE:” field to a value of “99”.
52
S Mode Programming
SPS-2000 Program Manual v1.30
Key Relocation (V3.0 and later)
Note: The Key Relocation screen was re-designed for ease of use beginning at software version 3.0. Tabs now separate four functions: PGM, DESIGN, LIST, and SELECT SCREEN. The multi-check and auto select options are functional beginning at version 3.00c.
The PGM Tab
Touch multi check if you wish to assign the same attributes to a group of locations at the same time. Touch as many positions as you wish and then make your selection.
Touch Copy to copy the keys on this screen to a range of other screens.
The DISPLAY BACKGROUND IMAGE option is available at version 2.01b or later.
Note that you must also download the image. See “Image Downloads” on page 33.
The keylink set here will display after entries for the initial keylink are satisfied or the keylink is exited.
The value entered in the “number of choice” field will determine the number of entries before the keylink is automatically closed.
For example, if “2” is set here, after 2 entries, the keylink will automatically close.
•
If the DONE key is enabled and you set
“0” here, unlimited keylink entries will be accepted. When the DONE key is pressed, the previous keylink will display.
•
If the DONE key is enabled and you wish to advance to the keylink set in the
“FUNCTION LIST KEY LINK” field, set the
“NUMBER OF CHOICE:” field to a value of
“99”.
If YES, the keylink will ask for the quantity of items.
SPS-2000 Program Manual v1.30 S Mode Programming
53
The Design Tab
The List Tab
54
S Mode Programming
Select one of 4 font sizes
Select black or white font color
Select black or white font color.
Touch here to select a button size/type. Inactive buttons (“X”) do not display in REG mode.
Touch auto select to automatically go to the next key after each program t
Touch multi check if you wish to assign the same attributes to a group of locations at the same time. Touch as many positions as you wish and then make your selection. (Note: Multi Check is functional for single size and inactive keys at V3.00g or later.)
Use the list tab to select the key function. Touch Function,
PLU, or KEY LINK and select a function for the key.
SPS-2000 Program Manual v1.30
The Select Screen Tab
Use the select screen tab to select the keylink you wish to program.
Touch to select another keylink.
SPS-2000 Program Manual v1.30 S Mode Programming
55
Function Key Code List
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16 CANCEL
17
18 CASH
20
21 CHECK
51
57 HOLD
58 INACTIVE
59
60
61
62
63
64 LIST CHECK 1
65
66
LIST CHECK 2
LIST CHECK 3
67 LIST CHECK 4
68
69 DELIVERY
24 CLEAR
25 CONTINUE
26
27
CURR CONV 1
CURR CONV 2
28
29
30
CURR CONV 3
CURR CONV 4
CURR CONV 5
32
73
74
75
76
78 MACRO 2
35
36 REPORT (v2.00j +)
37
39 EAT-IN
40 EMPLOYEE
44 EMPLOYEE 4
109
110
111
112
113
114
115
116
117
MACRO 33 *
MACRO 34 *
MACRO 35 *
MACRO 36 *
MACRO 37 *
MACRO 38 *
MACRO 39 *
MACRO 40 *
MACRO # (CODE No..)
129
130
131
132
133
134
135
119
120
121
122
123
124
125
126
127
128
MISC TEND 1
MISC TEND 2
MISC TEND 3
MISC TEND 4
MISC TEND 5
MISC TEND 6
MISC TEND 7
MISC TEND 8
MISC TEND 9
MISC TEND 10
MISC TEND 11
MISC TEND 12
MISC TEND 13
MISC TEND 14
MISC TEND 15
MISC TEND 16
MISC TEND #
56
S Mode Programming
146
SPS-2000 Program Manual v1.30
148 P/BAL
149
150
151
152
153
154
155
156
PAID OUT 1
PAID OUT 2
PAID OUT 3
PAID OUT 4
PAID OUT 5
PAID RECALL
189 PRICE LEVEL 20
190 PRINT
193 PROMO
194
195 QUIT
197
198
199
200
201
RECALL CHECK 1
RECALL CHECK 2
RECALL CHECK 3
RECALL CHECK 4
RECD ACCT 1
202
203
204
205
RECD ACCT 2
RECD ACCT 3
RECD ACCT 4
RECD ACCT 5
206 RECEIPT
207 REPEAT
208 SCALE
210
211 SPLIT ITEM
240 VALID
242 WASTE
243 FUNC.LIST#
244 X/TIME
165 % 9
166 %10
167 PLU
168
176
177
178
179
180
181
182
183
184
185
186
187
188
170
171
172
173
174
175
PRICE LEVEL 1
PRICE LEVEL 2
PRICE LEVEL 3
PRICE LEVEL 4
PRICE LEVEL 5
PRICE LEVEL 6
PRICE LEVEL 7
PRICE LEVEL 8
PRICE LEVEL 9
PRICE LEVEL 10
PRICE LEVEL 11
PRICE LEVEL 12
PRICE LEVEL 13
PRICE LEVEL 14
PRICE LEVEL 15
PRICE LEVEL 16
PRICE LEVEL 17
PRICE LEVEL 18
PRICE LEVEL 19
218 SUBTOTAL
220 TABLE 2
224
225
226
227
228
229
230
TAX EXEMPT
TAX SHIFT 1
TAX SHIFT 2
TAX SHIFT 3
TAX SHIFT 4
TAX SHIFT 5
TAX SHIFT 6
251 NEW CHECK 1
252 NEW CHECK 2
253
254
NEW CHECK 3
NEW CHECK 4
258 EFT Function (v2.00g +)
* Beginning at version 3.00j or later, Macro functions 33-40 are pre-assigned to the eight essential function keys:
DONE, PLU, PREV X/TIME, SUBTOTAL, CLEAR, CASH and VOID ITEM. This allows these keys to be reassigned through macro programming.
SPS-2000 Program Manual v1.30 S Mode Programming
57
Function Key Definitions
ADD CHECK
CANCEL
CASH
TIP DECLARE
CHECK
CHECK CASH
CHECK ENDORSE
CLEAR
CONTINUE
CURR. CONV. 1-5
TABLE DSP
NEXT DOLLAR
REPORT
DONE
DRIVE THRU
#
013
Use to add multiple guest checks (tracking balances or soft checks) for payment together. See "TRAY SUBTL" on page 62 to add separate transactions when you are not tracking balances.
016
Touch CANCEL to abort a transaction in progress. All current items are removed (voided).
018
Use CASH to finalize or tender cash sales. Change is computed when the amount of cash tendered is greater than the amount of the sale.
019
Use to declare employee tips if you are not using the employee time keeping feature. (If you are using employee time keeping, you are prompted to declare tips when clocking out.)
021
Use CHECK to finalize or tender check sales. Change is computed when the amount of the check tendered is greater than the amount of the sale.
022
Use the CHECK CASH key to exchange a check for cash outside of a sale.
023
If compulsory check endorsement is set with the CHECK key, use the
CHECK ENDORSE key to print the endorsement message after a check is inserted into the appropriate printer.
024
Use the CLEAR function to clear numeric entries or error conditions.
025
Use to override the pop-up employee function after a transaction.
Allows the employee to post an additional transaction without signing on again.
026-
030
Use to convert and display the value of the transaction in foreign currency. Only cash tender is allowed after touching a CURR CONV key. Change is calculated and issued in home currency.
033
Feature not currently available.
034
Touch the NEXT DOLLAR key to tender an amount the next whole dollar above the sale total. For example, if the sale total were $2.52, then the NEXT DOLLAR key would automatically tender $3.00.
036
You can print out reports from the REG tab using the REPORT key.
Reports are generated by first entering the report code, then touching the REPORT key, i.e.: [Report Code] [REPORT]. See “Report
Function Key Report Code Structure” on page 179 in the appendix of this manual. Note: This feature is available on v2.00j or later software.
037
Touch the DONE key to exit a keylink screen and return to the main screen.
038
DRIVE THRU is a subtotal function. Touch DRIVE THRU to record the amount of the transaction in the drive thru total on the financial report. Tax calculation can be changed to accommodate different tax rules for drive thru sales.
58
S Mode Programming
SPS-2000 Program Manual v1.30
EAT-IN
EMPLOYEE
EMPLOYEE (1-10)
ERR.CORR
FD/S SHIFT
FD/S SUBTL
FD/S TEND
GUEST #
HOLD
INACTIVE
LIST CHECK 1-4
DELIVERY
PARK DELIVERY
SERV DELIVERY
DELIVERY LIST
MACRO 1 - 40
SPS-2000 Program Manual v1.30
039
EAT-IN is a subtotal function. Touch EAT-IN to record the amount of the transaction in the eat-in total on the financial report. Tax calculation can be changed to accommodate different tax rules for eat-in sales.
Sales cannot be split between eat-in and take-out.
040
The EMPLOYEE # key is used to sign on a cashier, clerk, server or employee.
041-
050
The EMPLOYEE (1-10) keys can be programmed to sign on a specific employee when touched directly, without entering a code.
052
Touch ERR CORR immediately after an item to void that item.
053
Touch FD STMP SHIFT to shift the pre-programmed food stamp status of an item prior to its registration.
054
Touch FD STMP SUBTTL to display the total of food stamp eligible items registered in the current transaction.
055
Touch the FD STMP TEND key to tender Food Stamps after the display of the food stamp eligible subtotal. Depending upon function key programming, change less than $1 may be applied to any cash balance or issued as cash change.
056
Use to record the number of guests served by a transaction. The entry may be compulsory. The entry appears on receipts and the kitchen printer/KVS.
057
Use to identify an individual item, or an entire transaction so that the designated items will not print/display at the kitchen printer/KVS at the current finalization. Items designated as "hold" items will display on the screen with an "H".
058
Use to define an inactive key location.
064-
067
Touch LIST CHECK (for the appropriate tracking file) to display a list of all open soft checks in the file.
069
The Delivery function key is used to initiate a delivery transaction.
When touched, the Delivery key opens the customer record screen.
Here existing accounts can be opened, new accounts created, or existing accounts deleted.
070
The Park Delivery function key allows you to accept orders and hold them for preparation and delivery at a later time.
071
The Serv Delivery function key releases held parked orders for preparation.
072
Touch the Delivery List function key to display a list of open delivery check numbers, with name, time and status. From the list, you can release a parked order for preparation.
077-
116
Use to execute one of forty possible preprogrammed key sequences.
($1, $5, $10, and $20 are the default preset tender keys for macros 1-4.)
Beginning at version 3.00j or later, Macro functions 33-40 are preassigned to the eight essential function keys: DONE, PLU, PREV
X/TIME, SUBTOTAL, CLEAR, CASH and VOID ITEM. This allows these keys to be reassigned through macro programming.
S Mode Programming
59
MACRO #
MDSE RETURN
MISC TEND 1-16
MISC TEND #
MODIFIER 1-10
#/NO SALE
P/BAL
PAID OUT 1-5
PAID RECALL
%1 - %10
PLU
PRICE INQ
PRICE LVL 1-20
60
S Mode Programming
117
Use to execute one of the forty possible macros by entering the macro number and touching the MACRO # key.
118
Touch the MDSE RETURN key to adjust items inside or outside of a transaction.
119-
134
Touch a MISC TEND key to finalize or tender sales paid by various charges or other media. Tendering may or may not be allowed depending upon function key programming. (Charge is the default descriptor for MISC TEND #1)
135
Access any of the 16 possible miscellaneous tender functions by entering the tender number (1-16) and touching the MISC TEND # key.
136-
145
Preceding a PLU entry, a modifier key changes a digit of the PLU number, causing a different PLU to be registered. Modifier keys can be set to change any of the 14 PLU digit positions to any specified digit (0-
9).
147
Use to enter a non-adding memo number during a transaction (# function) or use to open the cash drawer outside of a sale (no sale function).
148
Enter an amount, and then touch the Manual Previous Balance (P/BAL) key to enter a beginning balance in a “Hard Check” system.
Transactions where the P/BAL key is used must be finalized with one of the STORE CHECK keys.
151-
155
Touch a PAID OUT key to remove cash, check or miscellaneous media from the drawer.
156
The PAID RECALL key is used to recall last x number of transactions, starting with the last transaction finalized. (X is determined in memory allocation.) Once recalled, a transaction could be reviewed (using the cursor keys or PAGE UP/PAGE DN). To exit the paid order view, touch CLEAR.
157-
166
Ten discount keys (%1 - %10) are available to handle various kinds of discounts, markdowns and adjustments to items or transactions.
167
Enter the PLU code number and touch PLU to register a PLU.
169
Touch the PRICE INQ to display the PLU price without actually registering the PLU.
170-
189
Touch a LEVEL key prior to a PLU entry to shift the price of a PLU to a different price set in PLU programming.
190
Touch the PRINT function to send items that require special preparation to the kitchen printer (or KVS) before the sale is finalized. An item can be programmed as an auto grill item, requiring the PRINT key to be touched every time the menu item is sold. This function does not affect normal kitchen printer/KVS routing. The PRINT function also sends items in group sequence using the “meal order feature” available at version 2.02n or later. Items are given a meal order priority through group programming. Each time the PRINT key is touched, the next priority of items will be release to the kitchen printer.
SPS-2000 Program Manual v1.30
PRINT CHECK
PRINT HOLD
PROMO
QUIT
RECEIPT ON/OFF
RECALL CHECK # 1-4
RECD ACCT 1-5
RECEIPT
REPEAT
SCALE
SEAT #
SPLIT ITEM
SPLIT PAY
191
Prints the soft guest check (tracking file) that is currently displayed.
The PRINT CHECK key may be programmed to store (service) the check automatically.
192
Use to remove the "hold" designation from an item or order, so that the items and their instructions are now sent to the kitchen printer/KVS at finalization.
193
Touch the PROMO key to void the price (the item remains) of an item.
Can be used for 2 for 1 promotions. A PROMO count is available for each menu item.
195
Touch QUIT to automatically sign off the current cashier/clerk.
196
Touch RECEIPT ON/OFF to toggle the receipt function from on to off
(versions before V2.01r) or touch [1] [RECEIPT ON/OFF] to turn receipt on or [2] [RECEIPT ON/OFF] to turn receipt off (versions 2.01r or later.) You must first have a receipt printer connected, identified to the register, and the print receipt automatically option (see General
Printing Options) turned on. Key also controls report printing.
197-
200
201-
205
The check tracking system can maintain only balances (hard check) or entire transactions (soft check) in the register memory. Four different tracking files can be separated to maintain, for example: restaurant checks, call-in orders, delivery orders, and/or table balances. Touch one of the four RECALL CHECK # keys directly to begin a tracking transaction, or enter the tracking number and touch the RECALL
CHECK # key to access the existing tracking balance.
Touch a RECD ACCT key to add cash, check or miscellaneous media to the drawer.
206
Touch the RECEIPT key to issue a transaction receipt at the designated receipt printer.
207
Touch the REPEAT key to quickly re-order a set of items. When a check is recalled, simply touch the REPEAT key to automatically register all of the items registered at the previous posting.
208
Touch the SCALE key to automatically display the weight from a scale connected to the register, or to manually enter a weight for extension.
209
Use to identify a specific seat (or person) within a transaction.
Facilitates separate payment by seat, and identifies to the food preparation staff (through the kitchen printer/KVS) how to assemble meals. Seat numbers may be assigned at the time of entry or, if necessary, later in the transaction.
211
When like items are consolidated in a transaction you can move the cursor to the item and touch the SPLIT ITEM key to display the items separately, instead of in consolidated form, used normally to assist the items to seat allocation.
212
Touch the SPLIT PAY key to divide the amount of a guest check into equal segments for payment by more than one person.
SPS-2000 Program Manual v1.30 S Mode Programming
61
STOCK INQ
STORE CHECK 1-4
SUBTOTAL
TABLE # (1-4)
TAKE-OUT
TAX EXEMPT
TAX SHIFT 1-6
CLK IN/OUT
TIP (1-3)
TRANSFER CHECK (1-4)
TRAY SUBTL
VALID
VOID ITEM
WASTE
FUNC.LIST#
213
Touch the STOCK INQ key, and then enter (or scan) an item to view the stock status of the item. (The item must be a stock item to use this function.)
214-
217
The check tracking system can maintain only balances (hard check) or entire transactions (soft check) in the register memory. Four different tracking files can be separated to maintain, for example, restaurant checks, call-in orders, delivery orders, and/or table balances. Touch one of the four STORE CHECK # keys to finalize a tracking transaction.
(This function is equivalent to a SERVICE function.)
218
Touch SUBTOTAL to display the message “SUBTOTAL” on the display. Although a running total is always displayed on the bottom of the screen, the SUBTOTAL key may be required before some functions, such as subtotal discount.
219-
222
Use to enter the table number of the check. If a table number is entered, the TABLE # key can also be used to recall the check.
223
TAKE-OUT is a subtotal function. Touch TAKE-OUT to record the amount of the transaction in the take-out total on the financial report.
Tax calculation can be changed to accommodate different tax rules for take-out sales. Sales cannot be split between eat-in and take-out.
224
The TAX EXEMPT can be preprogrammed to exempt specific taxes from a sale.
225-
230
Use to shift the preprogrammed tax status of an item. Touch before an item entry to make taxable.
231
Touch the CLK IN/OUT key to record start and stop work times for the registered employee. Hours worked are maintained by the time clock system.
232-
234
Use to enter a tip amount on a check.
235-
238
Use to transfer one or all open soft checks form one server to another server. A transfer check receipt will print.
239
Touch the TRAY SUBTL key to finalize a transaction that will be paid later with subsequent transactions. See "ADD CHECK" on page 58 to add multiple soft checks for payment.
240
Touch VALID to initiate a single line validation. (A printer with validation capability must be connected to the system and programmed appropriately.)
241
Touch the VOID ITEM key to remove an item from a transaction.
Locate the cursor on the item you wish to remove and touch the VOID
ITEM key.
242
Used to start and end entries of items that are wasted. A waste count is maintained for each item and inventory is adjusted.
243
Use to manually advance to a specific Key Link. Enter the Key link #
(1-200), touch the FUNC.LIST# key.
62
S Mode Programming
SPS-2000 Program Manual v1.30
X/TIME
STRING REPORT #
PARK ORDER
SERVE ORDER
KP ROUTING
SPLIT CHECK
244
Use the X/TIME key to multiply, to register split price items, or display the time in the REG mode.
245
Use to execute string report from REG mode. Enter number of string report to execute. Manager password may be required.
246
Used in conjunction with a kitchen video system and the SERVE
ORDER function key. Enter a number and touch PARK ORDER to park or "suspend" an order on the video monitor until the order is completely filled. In the case of a drive through order that cannot be completed when the customer arrives at the pick-up window, the operator would park the order until it was completely filled. The order would then be served or bumped by using the SERVE ORDER key.
247
Used in conjunction with a kitchen video system and the PARK
ORDER function key. Enter a number and touch SERVE ORDER to serve or bump the order from a video monitor. No video keypad is needed for this function.
248
The KP ROUTING key is used to override KP Time Period control.
For example, a restaurant might normally operate two kitchens at one time and one kitchen at other times. In case the volume of business changes, the manager might want to control the KP routing manually.
Also, a single item, or large order might be required to be sent to a different printer than normal. Select STAYDOWN or TRANS. POP
UP. To operate, before the transaction, touch [1] [KP ROUTING] for period one or [2] [KP ROUTING] for period two.
249
The Split Check function provides another method of breaking down checks for payment. Note that this method works best when check numbers are not automatically assigned. Many programmers/installers will use the table number as the check number, and in this situation the feature works quite well.
Place a “Split Check” key on the screen. Recall a check (table). Select the item you wish to place on a new check by touching the item on the display, then touching [Split Check]. Note that an asterisk (*) now displays next to the item. Continue to mark additional items to be assigned to a different check as necessary. Touch [Store Check]. The prompt will ask you to enter the number of the check you wish the designated items to be assigned to. Enter the check (table) number and touch OK. The original check with be stored automatically and the new check with the split items is open for storing or payment.
If you wish to use the split check feature in applications where checks are automatically assigned, you must first open and store a new check.
Make note of the check number. Then open the check from which you wish to split items from. Identify the items using the [Split Check] key as described above. Then when prompted to enter the number of the check where the selected items are to be assigned, enter the number of the new check you previously created.
SPS-2000 Program Manual v1.30 S Mode Programming
63
ALPHA TEXT
NEW CHECK1-4
PRICE CHANGE
EFT FUNC.
PREV LIST
NEXT LIST
250
Use to type a name or message that will be associated with a soft check.
Touch the ALPHA TEXT key anytime after a check has been opened, then type a message (up to 15 characters) using the alpha keyboard overlay and touch OK. Multiple message lines can be entered. The message is saved and printed/displayed with the order. A system option controls whether the message is printed on the guest check.
251-
254
The standard recall check key allows a check to be opened if it does not already exist. This is excellent in hospitality tracking, however for account management credit may not so readily be given. Therefore when this button is programmed accounts are not opened automatically.
A warning will indicate an account does not exist if an attempt is made to open using the recall check key. The new check button is used to open new accounts. The programmability for this key is automatically picked up from the status of the Recall check key.
256
This allows the pre-programmed price of an item to be changed though the sequence: [PRICE CHANGE] [PLU] [PRICE] [PRICE CHANGE].
The PLU flag “ALLOW PRICE CHANGE” controls this function.
258
When pressed (in REG Mode) a list of EFT functions display: Open
Batch, Close Current Batch, Close Batch with Debit, Gratuity Entry,
Get Gift Card Balance. See Authority Level Programming to restrict access to open/close batch functions. (Available v2.00h or later.)
268
(Available at v2.03j or later.) Moves the current screen (n) to the previous screen (n-1).
269
(Available at v2.03j or later.) Moves the current screen (n) to the next screen (n+1).
64
S Mode Programming
SPS-2000 Program Manual v1.30
System Options
This section is used to define the most fundamental parameters of the whole system such as, how many ECRs are in the network, which ECR number will store common data, etc.
► Select SYSTEM OPTIONS from the S mode PROGRAMMING MENU to display the S mode SYSTEM
OPTIONS Screen.
S-Mode System Options – Definitions
(1) REGISTER # (1-32)
This is the register number for this ECR. This is required to be a sequential number starting from 1 for each of the ECRs in an inter-register communications system.
(2) STORE #/STORE NAME
This is used during communications to indicate which store sales are collected from. Defaults to 0.
STORE NAME field added at software version 2.00s. Either a store name, store number, or both a store name and number can be entered. If store number alone is entered, store files will be saved on the SD card under the store number; if a store name alone, or if a store name and number are entered, store files will be saved on SD under a folder with the store name.
(3) IRC FROM REGISTER #
This is the number of the first ECR in an inter-register communications system. The norm is 1.
(4) IRC TO REGISTER #
This is the number for the last ECR in an inter-register communications system.
(5) IRC NUMBER OF RETRIES
The standard setting will be acceptable here, unless directed by CRS Support to use a different value.
This feature controls the number of requests to consolidate a ECR before failure is announced. This is default to 10 providing optimum network performance.
(6) PRINT DISPLAY DECIMAL POSITION
This is the number of decimal places the system will use.
(7) PASSWORD (0000 – NO PASSWORD)
Each of the reporting areas can be password protected to provide management restriction.
(8) SEND PLU DESCRIPTOR WHEN POLLED
This will send in addition to the normal information, the PLU description, when polled by a P.C.
(9) REG# HOLDS TIME IN/OUT DATA
The time clock, labor hours worked and costing analysis feature can be operated on any ECR, however the data is held centrally on one register.
(10) REG# HOLDS CHECK TRACKING DATA
The four check tracking files can be operated on any ECR. The files however are stored centrally, normally on ECR #1. On a more customized system this can be changed so that each tracking file is stored on a different ECR, the information will be available for central use.
SPS-2000 Program Manual v1.30 S Mode Programming
65
(11) REG# HOLDS BACKUP CHECK TRACKING DATA
The four check-tracking files can backed up on a second ECR.
(12) REG# HOLDS KP GLOBAL ORDER#
The order number printed on kitchen order tickets can be the register number followed by a consecutive number or can be held centrally and be a system consecutive number this is referred to as a global order number.
(13) REG# HOLDS CLERK INTERRUPT DATA
Identify the register that stores transaction data when the transaction is suspended while another clerk begins a different transaction.
(14) DISPLAY PRINTER ERROR WHEN POLLING
This controls the response of the ECR when a printer is not available to print a PC activated report. The option is default to No to ensure that if a printer is off line the communications will continue.
(15) ENABLE FRONT POWER SWITCH
If Yes, the front power switch is activated. This front power switch blanks/disables the touch screen without shutting down or re-booting the register.
(16) USE GRAPHIC TABLE MANAGEMENT
If Yes, Table Management is available. See “Table Management Program Guide” on page 160.
(17) NUMBER OF REGISTER THAT HOLDS THE DATATRAN
Enter the number of the ECR in the network where the DataTran is connected.
(18) MSR IS CONNECTED
Set MSR CONNECTED to DATATRAN if the MSR is connected to the DATATRAN; PDC if the MSR is connected to the PDC; REGISTER if the MSR is connected to the register (internal).
(19) PINPAD IS CONNECTED
Select DATATRAN or PDC.
(20) PINPAD KEY TYPE
Set the PIN encryption method: DUKPT or ROTATE KEY.
(21) TRACK# HOLDS DELIVERY TABLE
If using a delivery system, indicate the tracking file number that will be used to keep transactions input using the delivery function.
The following are used for sending reports via FTP:
# NETWORK SETTING?
Set to YES for FTP communications
AUTOMATICLLY GET IP ADDRESS? (DHCP)
Set to YES only if you want to get the OP address from the DHCP server. Consult your network administrator.
IP ADDRESS
Set only for IP polling.
SUBET MASK
Set only for IP polling.
66
S Mode Programming
SPS-2000 Program Manual v1.30
GATEWAY
If connected by router, set to IP Address of Router.
DNS SERVERS#1/DNS SERVERS#2
If connected to Internet, obtain from your Internet Service Provider (ISP).
PC CONNECTION TYPE
Select SERIAL or ETHERNET.
PC CONNECTION PORT NUMBER (2.02b or later)
Previously fixed at 8027, the port number is now configurable.
(22) USE MAGNETIC DALLAS KEY
Set to NO. This option is not currently available.
(23) DRAWER OPEN COUNT (1-5) (V2.01n or later)
Default is 1. This is the number of drawer open pulses sent to the drawer. This option only if you are experiencing intermittent cash drawer opening failure. (This feature requires version 1.08 kernel
(zimage). A full update must be performed.)
(24) DRAWER OPEN DELAY (100-1000 ms) (V2.01n or later)
Default is 100. This is the time delay between pulses, if multiple pulses are set on option #23. Set this option only if you are experiencing intermittent cash drawer opening failure. (This feature requires version 1.08 kernel (zimage). A full update must be performed.)
(25) DRAWER OPEN TIME (100-500 ms) (V2.01n or later)
Default is 200. This is the length of the drawer pulse. Set this option only if you are experiencing intermittent cash drawer opening failure. (This feature requires version 1.08 kernel (zimage). A full update must be performed.)
(26) STRONG PASSWORD (V3.00a or later)
If Yes, requires sign –in code and MCR sign on. Recommended for PABP (payment application best practices.
(27) SAVE EFT LOG FILE TO (V3.00g29 or later)
Choose SD, USB or NONE. Keep setting at NONE unless instructed by CRS support to collect a log file for troubleshooting purposes.
(28) SAVE PABP LOG FILE TO (V3.00g29 or later)
Choose SD or USB for integrated payment applications. This log is a required part of PABP and payment application validation. See the SPS-2000 Integrated Payment Operator’s and Programming Manual for more information about the PABP log file.
(29) DATATRAN TIMEOUT (30-240) (V3.00g29 or later)
For integrated payment applications, the recommended DATATRAN TIMEOUT setting is 240. When finalizing an integrated payment transaction, the time out count will display with the message
“WORKING”.
SPS-2000 Program Manual v1.30 S Mode Programming
67
Printer Driver Selections
This program allows you to change the commands for specific printers, or to set up a new printer by using generic (1-5) settings.
► Select PRINTER DRIVER SELECTIONS from the S mode PROGRAMMING MENU to display the
PRINTER DRIVER SELECTIONS screen.
This is used to customize existing printer formats or to add generic printers to the system. There is normally no need to change this information. The only exception being, printing bitmap images where the initialization code should be deleted for the appropriate printer.
Printer Driver - Definitions
PRINTER TYPE
Common printer types have been defined, ELLIX, SAMSUNG, CITIZEN, EPSON etc. These need no modification. The system does have some custom printer types available for technicians to allocate their own settings.
PRINTER TASKS: INITIALIZE, COMPRESS, Etc.
This is the definition area of the tasks the printer can perform such as bold, underline etc. This is a fixed field and is used to label the start and cancel codes. The only amendment that need be made is when a bitmap graphics image is to be printed and then, the initialization code should be deleted for the appropriate printer, or an alternatively is when a generic printer is to be allocated to the system.
SRP350 The SRP350 will support the storage of 255 NV bitmap images within the printer, all of which are retained in memory when the printer is turned off and on. To determine which image is printed, a different method other than the in-built bitmap download of program file 83 (logo image) is used. The images can be downloaded to the printer using the PC Utility (available from your supplier). When using this method it is necessary to change the logo print code. The SRP350 LOGO is as standard 1D2F this should be changed to 1C7XXX where XXX is the image number 001 to 255.
START CODE
This code relates to the printer task and is input from your own printer manual when defining a custom printer.
CANCEL
This code relates to the printer task and is input from your own printer manual when defining a custom printer.
68
S Mode Programming
SPS-2000 Program Manual v1.30
Define Port
There are 6 serial ports and 1 parallel port for peripheral device connection. (Note the standard rear display is connected to port #6.) The following section defines the peripheral device and the parameters for the peripheral that will be attached to the port.
► Select DEFINE PORT from the S mode PROGRAMMING MENU.
Define Port - Definitions
PORT
This is the number of the physical port located on the ECR. There are six serial ports, seven Ethernet ports and a parallel port.
PORT DESCRIPTION
This is an area in which you can type your own description of the task the port is carrying out, i.e.
KITCHEN PRINTER, HAND SCANNER etc. This description is for your own reference purposes.
BAUD RATE
This is the Baud Rate of the device, the communications speed of the peripheral.
PARITY
This is a standard peripheral definition; the information is normally supplied with the device.
DATA BITS
This is a standard peripheral definition; the information is normally supplied with the device.
STOP BITS
This is a standard peripheral definition; the information is normally supplied with the device.
RETRIES
This is the number of attempts that will be made to communicate with a device before failure is declared.
The default setting (3) is satisfactory for most commonly used peripherals.
PRINT BIT MAP
This allows printing of the previously downloaded graphics logo if the option has been defined as available within the memory allocation. Note the initialization code for the graphics printer should be deleted using the S-mode option:, Printer Driver Selections.
FEED LINES BEFORE PRINTING/AFTER PRINTING
This the number of lines to be fed before or after the printing is started, this will make the receipt longer, helping format the ticket for non-cutter printers.
LOGO SIZE
Select Normal, Double Height, Double Width, or Quadruple. This option is not used when using the new
NV image downloading.
LINES ON HARD SLIP
When a slip printer is used, this is the number of lines that can be printed on a loose paper printer, before a prompt for the next page appears.
SPS-2000 Program Manual v1.30 S Mode Programming
69
CUTTING AFTER PRINTING
When a printer has the capabilities of auto cut, this option will decide if that feature is to be used. For receipts it is commonly set to yes, however detail journal printers do not require this option.
IN CASE OF PRINTER, KICK THE DRAWER
Used to send audible beep using an optional beeper.
PRINT UPSIDE DOWN (V2.01n or later)
The printer will print the receipt upside down so that if the printer is wall-mounted, or placed vertically, the user can read easily. Supported printers are: SAM4s Ellix 10, Ellix 20, Bixolon SRP-350, Epson
TM-T88-2. If the number of lines to print in one print job exceeds 1000, the SPS-2000 will ignore the option.
DEVICE
This is the peripheral that will be connected to the port. The following options can be chosen:
DISABLE
The port is not active
PRINTER
The port will be used to operate a printer, you are then presented with a list of Printer types, all of which are pre-programmed with Driver setting.
VIDEO
This is a linked Kitchen Video System for the display of products.
POLLING
This is the on-line computer link.
SCALE
This links to an approved scale for weighted items. Beginning at version 3.00x, the “OZ Scale” setting supports the Avery Berkel 6712 POS scale, capable of weighing in ounces (rather than pounds).
NOTE: If weighing by ounces, the price per ounce must be preset in the PLU price. The scale will weigh in ounces and compute the correct price per ounce.
SCANNER
This option enables a barcode scanner.
EFT TERMINAL
This option links a DataTran integrated payment device.
CHANGER
This option allows a coin changer to be connected.
POLE DISPLAY
This option allows a pole display to be connected.
LIQUOR
This option allows a liquor dispenser to be connected.
PDC
The option enables a peripheral device controller.
70
S Mode Programming
SPS-2000 Program Manual v1.30
S-Mode Program Scan Printing
Programmed information can be sent to a printer so that a hard copy can be produced.
This option is ideal for keeping records of your machine’s settings – these can then be stored for future reference.
S-Mode Program Scans - Definitions
MEMORY ALLOCATION
Print the definitions of the systems features and file maximums.
SYSTEM OPTIONS
This prints the most basic of features such as terminal number and IRC (inter register communications) settings.
PRINTER DRIVER SELECTION
This print out shows how technicians have customized printers.
PORT DEVICE SELECTION
This prints the function of each of the physical ports listing the peripheral type connected.
DEFINE PORT PARAMETER
This prints the configuration of the ports, communication speed and unique settings.
RECEIPT REPRINT
Enter the consecutive number of the transaction you wish to print from the electronic journal.
SUPER MACRO
The supermacro (a troubleshooting resource) records the last 1000 keystrokes in REG mode (keystroke in other modes are not recorded). When 1000 keystrokes are entered, only the most current 1000 keystrokes are available (First-In-First-Out).
Touch SUPERMACRO to print. On the report, each keystroke is preceded with a code: [M] indicates the keystroke is a mode key; [K] indicates the keystroke is a function key list (keylink); [F] indicates the keystroke is a function key; [P] indicates the keystroke is a PLU entry. When printing is complete, a window displays “INITIALIZE SUPER MACRO?” Touch YES to clear the supermacro memory.
SPS-2000 Program Manual v1.30 S Mode Programming
71
Password Notes
The correct password is required to access Report Mode, P-Mode and S-Mode. Also, manager controlled activities can be completed only after the correct password is entered.
Default S-Mode and P-Mode Passwords are: 2000; the default Report Mode password is: 0000 (meaning no password entry is required to access this mode); the default manager password is: 9999. You can set your own 4-digit passwords by selecting Passwords in S mode.
Separate passwords for report levels (X and Z1-Z5) can be set in S-Mode System Option #7. Here the default password is also 0000, meaning all report levels can be accessed without password entry.
Authority Level option #40 (found in P-Mode/Employee) allows access to Report Mode, P-Mode and S-
Mode without password entry. Employees (such as managers) linked to an authority level with this option selected, can conveniently access all modes without password entry.
72
S Mode Programming
SPS-2000 Program Manual v1.30
Load Default Messages
This will revert back to default text for any messages, which may have been changed from their original settings, including:
ERROR MESSAGES
These are the onscreen display prompts warning the operator of miss-operations. Default Error Messages are listed on page 145.
SYSTEM DESCRIPTORS
These are the onscreen and reporting messages designed to assist the operator. Default System
Descriptors are listed on page 148.
Check Unlock/Clerk Unlock
This will reset locked operational checks or clerk interrupt details. This must be performed on the terminal set to store the data in the S-mode system option settings.
CHECK UNLOCK
Used in the unlikely event that an open check track number becomes locked and inoperable.
CLERK UNLOCK
Used in the unlikely event that an open clerk interrupt buffer becomes locked and inoperable.
SPS-2000 Program Manual v1.30 S Mode Programming
73
SRAM Backup
Use this function to load or save an end user programs or report data to or from an SD memory card.
Save End User Program
1. Insert a SD card in the SPS-2000.
NOTE: SD cards must be formatted as FAT 32. To avoid compatibility issues, CRS recommends that you purchase SD cards from CRS.
NOTE: This action will backup the SPS-2000 end user program on the SD Card in the path:
SPS2000/backup/xxxxxx, where xxxxxx is the store number set in S-Mode system options. When you restore programs, SPS-2000 will look for program data for the store number set in system options. If you had previously saved a program for the same store on the same SD card, the backup function will write over your previous end user program. Be sure to archive previously saved programs to your PC.
2. Go to S Mode and touch SRAM Backup.
3. Touch BACKUP PGM TO SD.
4. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the download is complete.
Restore End User Program
1. Verify that the store number set in S-Mode System Options matches the store number folder where the program you wish to restore is stored. Programs are stored on the SD card at
SPS2000/backup/xxxxxx, where xxxxxx is the store number set in S-Mode system options.
2. Insert the SD card containing the program in the SPS-2000.
3. Go to S Mode and touch SRAM Backup.
4. You must first restore the program’s memory allocation.
Touch LOAD MEMORY ALLOCATION FROM SD.
5. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the upload is complete.
6. Close the SRAM Backup screen, then touch Memory Clear. Touch 13. CLEAR PLU FILE. Even if just the default program is loaded, PLUs must be cleared before restoring the program. Close the
Memory Clear Screen
7. Touch SRAM Backup, then touch RESTORE PGM FROM SD.
8. From the selection dialog, select the individual program you with to restore or select “All” to restore all programs.
9. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the upload is complete.
74
S Mode Programming
SPS-2000 Program Manual v1.30
Save Reports
(Note that the Report Save/Restore feature requires V2.00s software or later.)
Reports can be saved to an SD card. All reports are saved simultaneously. Each report is saved in .rpt format.
You must use CRS supplied conversion utilities to convert to a text file (.txt) or Excel (.xls) format. Reports are stored on the SD card at the following path:
sps2000/backup/xxxxxx/REP_mmddyyyy
Where “xxxxxx” represents the 6-digit numeric store number (or store name) and “mmddyyyy” represents the date the reports were saved. Multiple stores and multiple report dates can be stored on the same SD card.
1. Insert a SD card in the SPS-2000.
2. Go to S Mode and touch SRAM Backup.
3. Touch SAVE REPORT TO SD.
4. At the Confirmation dialog box, touch YES. The PLEASE WAIT message displays until the download is complete.
Restore Reports
(Note that the Report Save/Restore feature requires V2.00s software or later.)
Previously saved reports may be able to be restored to the memory of the SPS-2000. Report saving is advised whenever service activity or updates are required on installed ECRs. In case of memory clearing, customer totals can be restored without disrupting store security or accounting.
1. Insert a SD card in the SPS-2000.
2. Go to S Mode and touch SRAM Backup.
3. Touch RESTORE REPORT FROM SD.
4. At the selection window, touch the date of the report(s) you wish to restore.
5. Touch OK. The PLEASE WAIT message displays until the upload is complete.
SPS-2000 Program Manual v1.30 S Mode Programming
75
FTP Transmission
Choose FTP Transmission to send reports via FTP (file transfer protocol). You must first set network options under S-Mode/SYSTEM OPTIONS. (If you wish to demonstrate this capability, contact CRS for demonstration documentation.)
1. Select SRAM BACKUP from the S-Mode menu.
2. Touch FTP TRANSMISSION. Enter the information for the FTP site you are connecting to:
Always set to 21
Set IP address of
FTP server
FTP ID &
Password will be assigned by the FTP site administrator
3. Touch CONNECT. If the connection is successful, the following screen displays:
4. Select file(s) you want to transmit and touch UPLOAD FILES.
76
S Mode Programming
SPS-2000 Program Manual v1.30
P Mode Programming
P-Mode Programming Menu
► From the Main Screen, touch the PGM tab. Enter the PGM Mode Password and touch OK to view the
PGM Mode screen.
SPS-2000 Program Manual v1.30 P Mode Programming
77
PLU
During PLU Programming, each PLU is assigned a descriptor, price or prices and a few unique options.
The remaining PLU options are determined by linking the individual PLU to a PLU Status Group. The PLU
Status Group contains all of the detailed programming option selections that might be assigned to a product.
Separate PLU Status Groups are defined to accommodate the needs of groups of PLUs. Like PLUs, the total number of PLU Status Groups is determined by memory allocation.
The maximum number of PLUs available is determined in memory allocation. (See "Memory Allocation" in
"S-Mode Programming".) Each PLU can be assigned a code number up to 17 digits in length.
1. From the PGM mode PROGRAMMING MENU touch PLU to view the PLU program selection window.
2. Touch the PLU program function you wish to perform. (Press PAGE DOWN to view the PLU
QUICK REGISTRATION option.)
78
P Mode Programming
SPS-2000 Program Manual v1.30
PLU Add & Change
1. From the PGM mode PROGRAMMING MENU touch PLU to view the PLU program selection window.
2. Touch PLU ADD & CHANGE to view the SELECT PLU screen.
3. You can edit existing PLUs in one of two ways:
Touch a PLU key located on the MAIN SCREEN, or touch PAGE UP/PAGE DOWN until the appropriate Key Link where you wish to edit a PLU displays. (Note: Beginning at v3.00c you can touch a modifier key, the a PLU.)
Enter the PLU number and touch OK.
You can add new PLUs in one of two ways:
New PLUs that are to be located the MAIN SCREEN or a Key Link must first be assigned to a key location in S mode. Once a new PLU is assigned to a screen, touch the key to add the PLU descriptor and options.
PLUs can be randomly added by entering a PLU number and touching OK, or by scanning an item if a scanner is connected.
SPS-2000 Program Manual v1.30 P Mode Programming
79
4. After a PLU is selected, the PLU PROGRAMMING screen displays at the PAGE #1 tab:
5. Touch the PAGE #2 tab and/or the PRICES tab to access the remaining PLU options.
PLU Option Definitions
DESCRIPTOR
This is the name of the saleable item, which will appear on receipts and reports.
STOCK LINK PLU #
PLUs can be set to reduce stock levels set at another PLU. Set the number of the PLU where stock is affected (by activity of this PLU) here. This capability has applications where multiple PLUs affect a single inventory item, for example cup counts for beverage items and where items are counted without regard to brand, such as cigarette packs.
MODIFIER QTY
This works in conjunction with the stock link PLU flag determining how many units are to be reduced from the main stock item. The field consists of two decimal places for example 50 would result in 0.50 being reduced from the stock of the item program within the stock link PLU field.
GROUP LINK #1
This field is used to provide the first type of sales analysis by category i.e. Beer, Lagers. Note: at version
2.01m or later, you can touch this field and select the group link from a list.
PLU STATUS GROUP LINK#
This is the programming for the status group link. Providing an en-masse program procedure for common system flags Note: at version 2.01m or later, you can touch this field and select the PLU Status Group link from a list.
PIECE COUNT
Enter a value in this field if you wish to use Product Mix and Product Projection reporting. The number of units entered here will be reflected in product mix reporting.
80
P Mode Programming
SPS-2000 Program Manual v1.30
PRODUCT MIX #1
This works in-conjunction with the piece count to track the unit and case usage of an item, each product can be programmed with the number of pieces used from an outer, i.e. the number of bottles from a case.
The piece count would control the number of bottles and the product mix group would control the description of the item and the number of units in case. In this field you would link the item to the product mix group.
RECEIPE#
This links to the ingredient inventory, so that when the product is sold, the quantities of each ingredient used are subtracted from stock for the allocated recipe and the appropriate sub recipes.
MIX & MATCH TABLE#
This is the promotion discount table, when the product or a mix of products, allocated to the same table are sold the appropriate discount information from the mix and match table will be subtracted.
PRINT NV IMAGE
Choose YES if you wish to print an image stored in the non-volatile area of the connected printer when the item is registered. The image, such as a coupon, will be printed at the bottom of the receipt. You must also select an image number in the PLU Status Group program to select a specific image from the many that may be resident in the printer NV memory.
INACTIVE
This status prevents the product from being sold, without deleting the PLU information. Inactive PLUs and any totals they retain will not appear on the PLU report.
PRESET
This determines whether the product is a pre-set or open price.
ALLOW PRICE CHANGE
If yes, the PLU price can be changed in REG mode with the sequence: [PRICE CHANGE] [PLU]
[PRICE] [PRICE CHANGE].
ALLOW PRESET/HALO OVERRIDE
This allows the operator to either manually enter over a pre-set priced item or to override a maximum sale limit. This works per PLU, with each product having individual restriction. If global restriction is required change the setting in systems options
FUNCTION LIST KEY LINK
Enter the number of the Key Link screen you wish to display immediately after this item is registered.
PRICE/HALO 1 - 4
This is either the pre-set price of an item, or the maximum sale amount of an open product.
PRICE LEVEL 1 - 4
Entered here is the price level for each product. There are 5 different prices per product, with up to twenty price levels available to be allocated. This allows the user to create a matrix of PLUs and Prices each accessed by one of the twenty price keys. When the price key is priced the product is then checked to determine if that price level (1-20) exists in any one of the five prices available. The standard is two prices per product set to price 1 and 2 this is generated as standard. A product price level sales report is available showing the total quantity and value sold per price and overall per product also a total for each price. This feature is not related to the five keyboard levels, they work independently
SPS-2000 Program Manual v1.30 P Mode Programming
81
PLU Delete
You can delete PLUs individually or by range.
1. From the PGM mode PROGRAMMING MENU touch PLU to view the PLU program selection window.
2. Touch PLU DELETE.
3. To delete PLUs individually, touch PLU DELETE BY ONE to display the SELECT PLU screen.
Identify a PLU by touching a key or by entering a PLU number a touching OK. Touch DELETE and then touch YES at the confirmation screen.
4. To delete a range of PLUs, touch PLU DELETE BY RANGE. Enter the FROM PLU# and TO
PLU#. Touch DELETE and then touch YES at the confirmation screen.
82
P Mode Programming
SPS-2000 Program Manual v1.30
PLU Status Group
PLU Status Groups allow memory to be used more efficiently. In most applications, large groups of PLUs are set with many identical options, while the PLU number, descriptor and price are unique. On the PLU
Programming each PLU is assigned a descriptor, price or prices and a few unique options. The remaining
PLU options are determined by linking the individual PLU to a PLU Status Group. The PLU Status Group contains all of the detailed programming selections that might be assigned to an individual PLU. Separate
PLU Status Groups can be set up to accommodate the needs of groups of PLUs. Like PLUs, the total number of PLU Status Groups is determined by memory allocation.
1. From the PGM mode PROGRAMMING MENU touch PLU to view the PLU program selection window.
2. Touch PLU STATUS GROUP to view the PLU STATUS GROUP PROGRAMMING screen.
3. Touch the PLU STATUS GROUP# button to or touch PREV. RECORD or NEXT RECORD to access a specific status group.
4. Touch a PAGE # tab to view additional options.
PLU Status Group Definitions
(1) TAXABLE BY RATES? (1-6)
Check for each tax rate to determine if the appropriate tax(es) is automatically calculated when the item is sold.
(2-3) GROUP LINK #2/GROUP LINK #3
If you wish to direct PLU sales to more than one group, enter the second or third reporting group for the
GROUPS and PLU BY GROUP reports here. Note the following related programs:
See “PLU” on page 78 to program the first reporting group for each PLU.
See “PLU Group” programming on page 98 to determine whether each individual group adds to the group total on the financial report.
SPS-2000 Program Manual v1.30 P Mode Programming
83
(4) ARE PLUS IN THIS GROUP INACTIVE?
Select YES if you wish PLUs reported to this group to be inactive (cannot be registered).
(5) IS PLU A CONDIMENT?
Condiments PLUs are different from non-condiment PLUs in the manner they display and print during operations. Non-condiment PLUs are used for “main” items. Condiment items are indented and displayed/printed below a main item so that condiments or cooking instructions are easily understood for each “main” item.
(6) COMPULSORY CONDIMENT ENTRY?
If Yes, then a condiment entry must follow the registration of a PLU.
(7) IS PLU SINGLE ITEM?
The transaction is finalized automatically when a single item PLU is registers as the first item in a sale.
(8) IS PLU NEGATIVE?
Negative PLUs subtract from a sale, rather than add to a sale.
(9) IS PLU HASH?
HASH PLUs do not affect certain totals in reports. See General Function Option #7 to determine specifically which totals are impacted by HASH PLUs.
(10) DOES PLU USE GALLONAGE?
Gallonage PLUs must be set as open PLUs. The PRICE/HALO must be set as the price per gallon. (The price is set at three decimal places, however the PLU programming screen will always display in a two digit decimal format. For example if a PLU is gallonage, a price of $1.299 per gallon would be set as
"12.99".) Gallonage PLUs will report the gallons sold in the activity counter on the PLU report by dividing the PLU total by the price per gallon.
(11) IS PLU FOOD STAMP ELIGIBLE?
A separate itemizer keeps a running total of food stamp eligible items in each transaction. Then if the sale is paid by food stamps, the food stamp eligible subtotal can be recalled.
(12) IS PLU MEMO?
Use Memo PLUs to display a descriptor on the screen or print a descriptor at a printer. Memo PLUs do not add to any total in the SPS-2000.
(13) IS PLU SCALEABLE?
Choose Yes if you wish to multiply items reporting to this group by a weight from a scale connected to the register. Pressing the SCALE key enters scale weights.
(14) AUTO SCALE ON THIS PLU?
If Yes, registrations of PLUs linked to this group will automatically multiply by the weight placed upon a scale connected to the register.
(15) AUTO TARE# (0-20)
If Yes, the tare # indicated here will automatically subtract from the weight from the scale. See “Function
Key Programming” for the SCALE key to preset tare weights.
84
P Mode Programming
SPS-2000 Program Manual v1.30
(16) STOCK PLU?
Choose Yes if you wish to track PLU stock, where each whole unit PLU activity subtracts a value of "1" from the stock counter. (Note that if multiplication or decimal multiplication is used when the PLU is registered, the resulting quantity of activity will subtract from the stock counter. Stock is maintained in increments to the second decimal position, i.e. “X.XX”.) See “PLU Stock” on page 87 for more information.
(17) LINK PLU#
If you wish the registration of the PLU assigned to this PLU status group to automatically cause the registration of another PLU, enter the number of the PLU you wish to register automatically here.
(18) NEGATIVE INVENTORY?
Use this option only if you are using the recipe and ingredient inventory system and you are using PLUs to designate subtractions from a menu item. For example, a PLU may be designated "No Cheese" by designating a PLU to print this instruction. By assigning the "No Cheese" PLU to a PLU Status Group with this setting at Yes the inventory records for cheese will be maintained correctly.
(19) ALLOW PROMO?
Choose Yes if you wish to allow the PROMO operation: i.e. buy two get one free. PROMO activity will remove the item cost from the sale, but the count will include the promo item.
(20) ALLOW WASTE?
If Yes, the WASTE function is allowed on PLUs reporting to this group.
(21) ALLOW DISCOUNT?
If Yes, the operation of an item discount after registration of a PLU reporting to this group is allowed.
(22) ALLOW SURCHARGE?
If Yes, the operation of an item surcharge after registration of a PLU reporting to this group is allowed.
(23) COMPULSORY VALIDATION
If Yes, validation must be performed after registration of a PLU reporting to this group before any other register activity is allowed.
(24) IS NON-ADD# COMPULSORY?
If Yes, a numeric entry must be made into the Non-Add # key before registration of a PLU reporting to this group is allowed
(25) PRINT ON KV?
Select Yes if PLUs in this group are to be sent to a kitchen video.
(26) KITCHEN VIDEO GROUP#
Select the kitchen video group to which PLUs in this group are to be sent. Condiment PLUs with a "0" status here will "follow" the last main item.
(27) COLOR TO DISPLAY ON KV (0-31)
The color code set here will control the color or screen format displayed on an optional kitchen video system requisition screen. Color codes vary by KVS system. Refer to the documentation for your video system for specific information.
SPS-2000 Program Manual v1.30 P Mode Programming
85
(28) PRINT ON KP?
Select Yes if PLUs in this group are to be sent to a kitchen printer.
(29) PRINT ON KP GROUP#
Select the kitchen printer group or groups to which PLUs in this group are to be sent.
(30) PRINT RED ON KITCHEN PRINTERS?
Set to Yes if you wish PLUs in this group to print in red on the kitchen printer, i.e. condiments might be printed red. Red/black printer must be used.
(31) PRINT RED ON RECEIPT?
Set to Yes if you wish PLUs in this group to print in red on the receipt. Red/black printer must be used.
(32) PRINT ON RECEIPT?
Must be set to Yes for PLUs in this group to print on the receipt.
(33) PRINT ON JOURNAL?
Must be set to Yes for PLUs in this group to print on the journal or collect in the electronic journal.
(34) DISPLAY ON REGISTER SCREEN?
Set to No if you wish the registration of PLUs in this group not to display on the register operator screen.
(35) PRINT ON GUEST CHECKS?
Must be set to Yes for PLUs in this group to print on the guest check.
(36) PRINT PRICE ON GUEST CHECKS?
Prints the descriptor only, rather than descriptor and price on guest checks.
(37) PRINT PRICE ON RECEIPT/DETAIL?
Prints descriptor only, rather than descriptor and price on receipt and detail.
(38) AUTO GRILL?
Select Yes for this option to send items in this group to the kitchen printer designated in the next field.
Items are sent with a one-item delay (at the next item or at subtotal.)
(39) AUTO GRILL KP GROUP#
Enter the kitchen printer number for printing of auto grill items.
(40) LINKED NV IMAGE#
If you intend to print an image when an item linked to this status group is registered, indicate the number of the image that is stored in the printer’s NV memory area here. You must also choose YES at the “Print
NV Image” option of the individual PLU program. The image, such as a coupon, will be printed at the bottom of the receipt.
(41) PRODUCT MIX #2
If you are using product mix reporting, enter the number of the second product mix item here. See
“Product Mix Items” on page 141 for more information.
86
P Mode Programming
SPS-2000 Program Manual v1.30
(42) ELIGIBLE FOR CANADIAN DONUT LAW
Special Provincial or State sales tax laws might change the taxable status of an item depending upon the quantity sold. Donuts, for example, might be taxable when sold individually at a bakery, but be nontaxable when sold by the dozen.
In such a case select a numeric value for this field, and also select Yes to the appropriate tax status. The numeric value represents the quantity of donuts to apply, i.e. enter “1” for a single donut; enter “2” for a
2-pack of donuts. Also, set tax option #3 (see "(65) PLU STATUS FOR LABWARE CONDIMENT
For later use with Labware application.
(66) PLU STATUS FOR LABWARE COOK LINK
For later use with Labware application.
(67) DO NOT ALLOW VOID DISCOUNT IN SALE
(Option added at version 3.00g30) Choose YES here when when discounts are set to net item totals. If a discount is applied, and later voided, balancing issues may result.
Tax Option" on page 114) with the quantity at which you wish tax to be exempted, for example 12.
Registration of PLUs reported to this status group will charge tax until the quantity with the transaction reaches 12. When 12 or more are registered, all will be sold without tax.
(43) AGE VERIFICATION (0-5)
Enter 1-5 to set the age category. The operator will be forced to enter a date of birth that indicates an age higher than the age of 89 to set the minimum age for each of up to 5 categories.
(44) IS PLU GIFT CARD
Default is NONE. Select ACTIVATE or ADD if PLUs linked to this group activate or add to an integrated payment gift card program.
(45) ADD CONDIMENT PRICE TO MAIN PLU (added V2.01n)
When this option is Yes, the price of the condiment is not displayed, instead it is added to the main item.
(46)HOLD AUTOMATICALLY (added V2.02b)
This flag allows PLUs to be placed on HOLD to the KP/KVS automatically.
PLU Stock
You can adjust inventory levels for PLUs with stock status. (The PLU must be linked to a PLU Status Group with option# 16 Stock PLU? set to YES.)
1. From the PGM mode PROGRAMMING MENU touch PLU to view the PLU program selection window.
2. Touch PLU STOCK and then touch ADD to add new inventory, OVERRIDE to enter a new inventory value, or SUBTRACT to subtract inventory.
3. Use the PLU Select screen to find the PLU you wish to adjust.
4. Touch the current stock value, and then enter an inventory value. Use the decimal key to enter whole or partial unit values. When complete, a chit is printed (v3.00g30 or later).
SPS-2000 Program Manual v1.30 P Mode Programming
87
PLU Minimum Stock
You can enter minimum inventory levels for PLUs with stock status. (The PLU must be linked to a PLU
Status Group with option# 16 Stock PLU? set to YES.) When the level of a stock item falls below the minimum inventory level set here, the item will appear on the PLU MINIMUM STOCK report. Optionally, a warning “BELOW MINIMUM STOCK” can display when if the PLU is registered and stock is below the minimum level. (See SYSTEM OPTIONS, GENERAL FUNCTION OPTION #57 to activate the warning.)
When multiple registers are installed, stock count is checked by IRC at each stock item registration.
1. From the PGM mode PROGRAMMING MENU touch PLU to view the PLU program selection window.
2. Touch PLU MINIMUM STOCK.
3. Use the PLU Select screen to find the PLU you wish to adjust.
4. Touch the minimum stock value, and then enter minimum stock value. Use the decimal key to enter whole or partial unit values.
Non-PLU Code
The NON-PLU Code program must be set if you wish to scan UPCs (using the EAN 13 code) with embedded prices, weights or quantities.
Within the EAN 13 code, the first two digits (part a) are used as an identifier and the last digit (part c) is used as a check digit. The remaining 10 digits (part b) contain the product code and the price (or weight or quantity).
021234500250 c) Check digit a) Identifier b) Product code & price
There are 11 identifier numbers available for non-PLU code programming: “02” and “20” through “29”. The purpose of this program is to define the format of the 10-digit part b for each possible identifier.
For example:
The structure of Non PLU identifier “02” could be defined to use 5 digits for the product code and 5 digits for the price.
The structure of Non PLU identifier “20” cdould be defined to use 6 digits for the product code and 4 digits for the price.
To Program Non-PLU codes:
1. Select NON-CODE PLU from the PGM mode MENU to display the NON-CODE PLU
PROGRAMMING screen.
2. Choose one of the non-PLU identifiers (“02” or “20” through “29”).
3. The NON-PLU# PROGRAMMING screen displays for the identifier you have chosen to program.
4. Use the field definitions below as a reference in filling the fields of this screen.
5. Press CLOSE to return to the NON-CODE PLU PROGRAMMING screen.
88
P Mode Programming
SPS-2000 Program Manual v1.30
NON-PLU Code Field Definitions
LENGTH OF FIELD 1
Assign the length of the product code field. (The length of field 1 plus field 2 must equal 10.)
LENGTH OF FIELD 2
Assign the length of the price/weight/quantity field. (The length of field 1 plus field 2 must equal 10.)
CONTENT OF FIELD 2
Select the type of content for field 2: price, weight or quantity.
USE PRICE CHECK DIGIT
Select “Y” if the price field includes a check digit.
Note that the price check digit is not the non-PLU code check digit (the last digit of the 13-digit non-PLU field, identified as “part c” in the example above.) If the price check digit is set to “Y”, it occupy one of the 10 digits in “part b” between the product code & price field.
TAB OR DECIMAL POINT OF FIELD 2
Enter the decimal point position for the price/weight/quantity field.
Age Verification
Sale of age-restricted items (i.e. alcohol, tobacco) can be controlled at the point of sale by forcing to operator to enter a date of birth before a controlled item can be registered. Because you may wish to use this feature for items controlled at a different age (i.e. alcohol may be allowed at age 21 and tobacco may be allowed at age 18), up to five different ages can be entered here. The age category (1-5) is entered at the appropriate
PLU Status group program.
1. Select PLU from the PGM mode PROGRAMMING MENU, and then select AGE
VERIFICATION to display the AGE VERIFICATION Screen.
2. Type an age for the first age category, press OK.
3. If necessary enter ages for the remaining age categories.
4. Press CLOSE to return to the PGM mode MENU.
SPS-2000 Program Manual v1.30 P Mode Programming
89
Age Verification by Card Swipe
(Available with V3.00w or later; California support added at V3.00g25) Many state drivers licenses encode driver data on a mag stripe. When age entry is required, the drivers license can be swiped and the age verified. This feature is enabled by identifying track data on the Age Verification program screen.
Operate by swiping the drivers license (or manually entering the date) when the CUSTOMER DATE OF
BIRTH window displays.
1. To program, go to S/SELF TEST/MSR and swipe the drivers license mag strip. The mag stripe data will display on the screen as in the example below:
Track 2
Track 1
25
1 5
10 20
In this example the bith date “19590605” (June 5,
1959) is in YYYYMMDD format, beginning at data column 25. The number of digits to be read (for
DIGIT OF NUMBER field) is “8”. Be sure to count the “;” semicolon character at the beginning of the string as a digit.
2. Identify the date of birth in the data and determine the track where the date is located (track 1 or track 2).
3. Determine the format of the date (i.e. YYYYMMDD). (Added at V3.00g25: “MMYYY99YY” date format for California. California must also choose “10” for “digit of number” option.)
4. Count the columns of data and determine the number of the column where the birth date begins
(START OF NUMBER).
5. Go to P/PLU/AGE VERIFICATION and make the appropriate entries in the READ TRACK,
START OF NUMBER, DIGIT OF NUMBER and DATE TYPE fields.
Enter Ages for Each
Verification
Category
Here
Enter Mag
Stripe Date
Identification for Drivers
License Here
90
P Mode Programming
SPS-2000 Program Manual v1.30
PLU Quick Registration
The PLU Quick Registration Program provides a fast method of programming groups, PLUs and their essential options. After PLUs are added or edited PLU using this method, you can choose to automatically make menu screens based upon the group/PLU data. Use this program when creating an end-user program for the first time. PLU Quick Registration is not recommended for ongoing program maintenance.
1. If you are creating a new program, it is recommended that you clear all PLU data before using PLU
Quick Registration. Select MEMORY CLEAR from the S Mode menu, then select option #13
CLEAR PLU FILE.
2. Select PLU from the P Mode menu and then from the PLU option menu, touch PAGE DOWN to view and select the PLU QUICK REGISTRATION option. A blank PLU QUICK REGISTRATION
PROGRAM screen displays. The screen command buttons that are displayed across the top of the screen are described below:
Command Buttons
Command
Button
GROUP
PLU
ADD
DEL
STS GRP
STOCK
Function
Touch GROUP to set descriptors for groups 1-32.
Touch PLU to set PLUs
Touch ADD to add a PLU. You will be prompted to enter a descriptor and a price.
PLUs will be added in sequential order for each group:
Group #1 PLUs are issued beginning with PLU #1001,
Group #2 PLUs are issued beginning with PLU #2001, and so on for each group up to group #32, which will issue PLU numbers beginning with #32001.
Select a PLU and touch DEL to delete the PLU.
Select a PLU and touch STS GRP to edit the options for the Status Group to which the PLU is linked. (The STS GRP and STOCK options will determine the status group to which the PLU is assigned.)
Select a PLU and touch STOCK to set stock levels for the PLU.
SPS-2000 Program Manual v1.30 P Mode Programming
91
3. Once PLUs are added they will be displayed as a list on the screen:
PLU Selection
Check Box
Group List
Box
Each Column of PLU data is described in the table below:
Column Explanation
GROUP
PLU#
DESCRIPTOR
Touch a GROUP in the group selection box to display the PLUs that are linked to the group. Use the arrow up (↑) or arrow down (↓) keys at the bottom of the box to view
Groups 1-16 or 17-32.
This is field display only and cannot be edited. Use the check box to the left of the PLU number to select the PLU for editing. PLUs assigned to group 1 will begin with PLU
#1001 and range to PLU #1999; PLUs assigned to group 2 will range from 2001-2999, etc.
Touch the current descriptor button to edit the descriptor field.
STOCK
STOCK
KP
PRICE
Select a PLU and touch STOCK to set the stock level for the PLU.
Touch STS GRP and/or STOCK buttons to toggle from NO to YES. The YES/NO status determines the status group to which the PLU is assigned:
PLUs with option NO STOCK and NO KP are linked to PLU STATUS
GROUP #1.
PLUs with option STOCK and NO KP are linked to PLU STATUS GROUP
#2.
PLUs with option NO STOCK and KP are linked to PLU STATUS GROUP
#3.
PLUs with option STOCK and KP are linked to PLU STATUS GROUP #4.
Touch the current price button to edit the price field.
When more than 10 PLUs are displayed on the screen, use the arrow up (↑) or arrow down (↓) keys at the bottom of the screen to view additional PLUs.
Touch CLOSE to exit (after v3.00c touch MAKE MENU) the PLU QUICK REGISTRATION
PROGRAM. You will be prompted: “DO YOU WANT TO MAKE A MENU SCREEN?” If you select YES, new menu screens will be created automatically based upon the group and PLU data you have programmed.
92
P Mode Programming
SPS-2000 Program Manual v1.30
Using a 101-Key Keyboard with PLU Quick Registration
When a PS\2 keyboard is connected to the SPS-2000, the keyboard may be used for inputting PLU Quick
Registration data. The following keys are control keys:
Numeric 1 to 0 – Select a PLU.
F1 / F2 – Select GROUP / PLU screen.
F3 – Add selected PLU.
F4 – Delete selected PLU.
F6 – Edit PLU status group of selected PLU.
F8 - Edit stock of selected PLU.
UP/DOWN/LEFT/RIGHT – Navigate GROUP.
PAGE UP/DOWN – Navigate PLU
ESC/ENTER – Exit current screen.
PLU Quick Registration Example
A simple menu consists of:
2 Grill items: Hamburger and Cheeseburger
2 Drink items: Pepsi and Coke
2 Ice Cream items: Cones and Malts
Program these items using the Quick Registration method:
1. Clear all PLU data: Select MEMORY CLEAR from the S Mode menu, then select option #13
CLEAR PLU FILE.
2. Select PLU from the P Mode menu and then from the PLU option menu, touch PAGE DOWN to view and select the PLU QUICK REGISTRATION option. A blank PLU QUICK REGISTRATION
PROGRAM screen displays.
3. Touch GROUP.
Set the Group 01 descriptor to GRILL
Set the Group 02 descriptor to DRINKS
Set the Group 03 descriptor to ICE CREAM
4. Touch PLU.
5. Select the GRILL group (default).
6. Touch ADD
Type the descriptor: Hamburger, touch OK.
Enter the price: 299, touch OK
7. Touch ADD
Type the descriptor: Cheeseburger, touch OK.
Enter the price: 399, touch OK
8. Select the DRINKS group.
9. Touch ADD
Type the descriptor: Pepsi, touch OK.
Enter the price: 100, touch OK
SPS-2000 Program Manual v1.30 P Mode Programming
93
10. Touch ADD
Type the descriptor: Coke, touch OK.
Enter the price: 100, touch OK
11. Select the ICE CREAM group.
12. Touch ADD
Type the descriptor: Cone, touch OK.
Enter the price: 199, touch OK
13. Touch ADD
Type the descriptor: MALT, touch OK.
Enter the price: 299, touch OK
14. Touch CLOSE. The message “Do You Want To Make Menu Screen” displays.
15. Touch YES. The message “Do You Want To Configure Printers” displays. If No is selected, the register will not change Port Parameters and does not change KP Printer Routing.
16. From the PGM menu, touch SYSTEM OPTION, and then touch LEVEL / MODIFIER OPTIONS.
Set option #9 (the default screen) to Key Link #73, also reset Level/Modifier #11, “Use Clerk’s
Default Screen Level” to NO. Touch CLOSE to exit the program.
17. Touch the REG tab. The newly created menu screen displays:
The GRILL key is Key
Link function #073
Items linked to the
GRILL group display on Key Link screen
#073
94
P Mode Programming
SPS-2000 Program Manual v1.30
18. Touch DRINKS to view the drink items.
The DRINKS key is
Key Link function
#077
Items linked to the
DRINKS group display on Key Link screen
#077
19. Touch ICE CREAM to view the ice cream items.
The ICE CREAM key is
Key Link function
#081
Items linked to the ICE
CREAM group display on Key Link screen
#081
SPS-2000 Program Manual v1.30 P Mode Programming
95
Format of Automatically Created Screens
Key Links
(Groups)
PLUs
Function
Keys
Function
Keys
Key
Links
PLUs
Screens created by the Quick Registration System are located beginning at Key Link #73.
Group #1 will use Key Links 73-76; Group #2 will use Key Links 77-80, etc. (Use PGM Mode
System Option/ Level/Modifier Option #9 to set the default screen to Key Link #73, also reset
Level/Modifier #11, “Use Clerk’s Default Screen Level” to NO. You must make these settings to view the menu screens created by the Quick Registration system in REG mode.)
Groups
Groups are used to organize sets of items. For example, Grill Items, Drinks, and Ice Cream items might be separated into different groups. Groups are Key Link keys located on the top two rows of the screen. The group currently selected displays in a gray color and the PLUs associated with that group are displayed below. Touch another group Key Link to display it’s
PLUs. Up to eight groups can be displayed simultaneously. When more that eight groups are used, arrow keys display. Touch the arrow down (↓) to display the next set of groups. Touch the arrow up (↑) key to display the previous set of groups. A total of 32 groups can be activated using the PLU Quick Registration System.
Up to 18 PLU items for each group can be displayed simultaneously; a maximum of 72 PLUs may be assigned to each group using the PLU Quick Registration system. When more that 18
PLUs are used in one group, arrow keys automatically display. Touch the arrow right (→) to display the next set of PLUs. Touch the arrow left (←) key to display the previous set of PLUs.
Note PLUs created using the standard PLU program method will not be used by the PLU Quick
Registration system.
The 10 keys located on the bottom two rows of the main screen will be copied to each screen created with the PLU Quick Registration feature. The EMPLOYEE key should be located in this area.
96
P Mode Programming
SPS-2000 Program Manual v1.30
PLU Integrity Check
Choosing this option will check the PLU file for invalid programming and print a report listing PLUs that have invalid programming. An example of invalid programming is a PLU programmed with PLU STATUS
GROUP #400 when only 200 PLU STATUS GROUPS are allocated in MEMORY ALLOCATION. This feature will check the flags STOCK LINK PLU, MODIFIER QTY, GROUP, PLU STATUS GROUP, PIECE
COUNT, PRODUCT MIX#, RECIPE#, M&M# and FUNCTION LIST#. When programming at the register it is not possible to program these fields with invalid programming, however if memory allocation is changed after the program is created these fields could become invalid.
SPS-2000 Program Manual v1.30 P Mode Programming
97
PLU Group
Groups are designated to accumulate PLU sales for convenient reporting totals. A PLU can send its' sales information to up to 3 groups. Group Link #1 is set in PLU programming. Group Links #2 and #3 are set in
PLU Status Group programming.
This program allows you to set up the groups that PLU sales will report to. There are 99 groups. Here you can program the group descriptor that appears on reports, and you can determine whether that group will add to the total of all groups that appears at the end of the Group report.
1. From the P Mode menu screen, touch Group to display group program options.
2. Touch Next Record or Prev. Record to view the group you wish to program.
3. Set the Descriptor and Add to Group Total status.
4. (V2.02n or later) If the Print key is to issue requisitions sequentially by meal order number, set the sequence of the group here. For example if the print key is to release appetizers first, then main items, and then desserts, separate appetizers, main items and desserts by group and set the “MEAL
ORDER FOR KP” as 1, 2, and 3 respectively. You must also set Print Key (key #190) Function key
Program option “Automatically Print Meal Orderly” to Yes.
5. Touch Close to exit.
98
P Mode Programming
SPS-2000 Program Manual v1.30
Function Key
Function key options vary by key. A "Function Key Program Summary" on the following page lists each function and its options.
Note: Although each 12 character function key descriptor is set here, if a function key appears on the financial or employee report, the descriptor that prints on the report may be set separately. See “Messages” on page 145to set descriptors on the financial or employee report. See “Report Printing Option Definitions” on page 125 to determine which descriptors are used on reports.
1. Select FUNCTION KEY from the PGM Mode menu to display the SELECT FUNCTION KEY
Screen.
2. Select a function to program:
Enter the function key code and touch OK,
Or, use the PAGE UP/PAGE DOWN keys to view and touch the function key you wish to program.
The programming option screen for the function will display.
3. Refer to Function Key Programming Notes on page 104 if you need assistance with specific options.
SPS-2000 Program Manual v1.30 P Mode Programming
99
Function Key Program Summary
Other Options
ADD CHECK
CANCEL
CASH
TIP DECLARE
CHECK
CHECK CASH
CHECK ENDORSE
CLEAR
CONTINUE
CURR. CONV. 1-5
TABLE DSP
NEXT DOLLAR
DONE
DRIVE THRU
EAT-IN
EMPLOYEE
EMPLOYEE (1-10)
ERR.CORR
FD/S SHIFT
FD/S SUBTL
X X
X X X X Print Receipt?
X X X Exempt Tax (1-6)
Open Drawer
Amount Tender Compulsory
Disable Under Tendering
Allow Under tendering in X only
Coin Changer Port
X X X
X X X Exempt Tax (1-6)
Open Drawer
Compulsory Check Endorsement
Amount Tender Compulsory
Disable Under Tendering
Allow Under tendering in X only
X X X X HALO Override in X only
X Printing Port
X
X
X Rate
Change in Foreign Currency?
Linked Drawer # (0-2)
Currency Rate Decimal Position (0-6)
X
X
X
X X Exempt Tax (1-6)?
KP Period Override (0=No Override)
Price Level (0-20)
X X Exempt Tax (1-6)?
KP Period Override (0=No Override)
Price Level (0-20)
X
X
X X X X
X
X
100
P Mode Programming
SPS-2000 Program Manual v1.30
FD/S TEND
GUEST #
HOLD
INACTIVE
LIST CHECK 1-4
MACRO 1 - 40
MACRO #
MDSE RETURN
MISC TEND 1-16
MISC TEND #
MODIFIER 1-10
#/NO SALE
P/BAL
PAID OUT 1-5
X X Exempt Tax (1-6)
Open Drawer?
Allow Decimal Entry?
Food Stamp Change: Cash or Food Stamp
Allow Over Tender?
Connect EFT Terminal?
X Compulsory After Beginning of Check?
Compulsory for All Sales?
Print on KP?
Print on Receipt?
X X
X
X X
Beginning at version 3.00j or later, Macro functions 33-40 are pre-assigned to the eight essential function keys:
DONE, PLU, PREV X/TIME, SUBTOTAL, CLEAR,
CASH and VOID ITEM. This allows these keys to be reassigned through macro programming.
X
X X X X Add to Net Grand Total?
Skip Adjustment of PLU Total?
Return Current Prince Level Only?
X X X Exempt Tax (1-6)
Open Drawer?
Amount Tender Compulsory?
Disable Under Tendering?
Allow Under Tendering in X Only?
Non-add Number Entry Compulsory?
Key is Credit/Debit/Gift (Note: Option for Gift-NSF
added at v2.03j; allows gift card undertender)
Connect to EFT on Recd Acct
X
X X Modify Descriptor Only (Not PLU#)?
Print Descriptor on Guest Check?
Print Descriptor on Receipt?
Print Descriptor on KP?
Affect Digit 1-18 of PLU#
Value of Affected Digit (0-9) of PLU
X X HALO Digits for Non-Add Entry (0-14)
Allow No Sale Function?
Allow Non-Add Function?
No Sale in X Only?
No Sale Inactive After Non-Add Entry?
Enforce Non-Add at Beginning of Sale?
Comp. Non-Add# Must Match HALO Digit#?
X Must be Entered at Start of Sale?
Compulsory P/Bal?
X X X X
SPS-2000 Program Manual v1.30 P Mode Programming
101
PAID RECALL
%1 - %10
PLU
PRICE INQ
PRICE LVL 1-20
PRINT CHECK
PRINT HOLD
PROMO
QUIT
RECEIPT ON/OFF
RECALL CHECK #
1-4
RECD ACCT 1-5
RECEIPT
REPEAT
SCALE
SEAT #
SPLIT ITEM
SPLIT PAY
STOCK INQ
X X Use EJ Recall (V3.00g29 or later)
X X X Taxable (1-6)?
Function is Inactive?
Function: Sale/Item
Function: Amount/Percent
Function: Plus/Minus
Function: Open/Preset
Selective Discount?
X
X X Function is: Stay down/Popup
X X Prevent Zero Price Sale
Alternative Price Level
X Output Printer# (1-20)
Automatically Print Meal Orderly (v2.02n)
X Print Check Automatically Services Check?
Print Consec# on Guest Check?
X X
X X Taxable (1-6)?
X
X
X X Enforce Seat#?
Table Entry Required?
Multiple Checks allowed for Each Table?
Guest Count Entry Required?
Compulsory for All Sales?
Assigned by Register?
Opening Employee has Exclusive Access?
Print Check# on Receipt? On Journal? On KP?
Drive Thru Feature Enabled?
Print Receipt After Store Check?
Scan Check#?
Length of Check# in Digits (0-10)
X X X X
X Print “REPRINT” on Receipt?
X X
X X Allow Manual Entry of Weight?
Inhibit Tare Weight Entry?
Tare Entry in X Only?
Tare Entry is Compulsory?
Weight Symbol: Kg/Lb
Set Tare Weights
X X Function is Stay down/Popup?
X X
X X
X X Function is Stay down/Popup?
102
P Mode Programming
SPS-2000 Program Manual v1.30
STORE CHECK 1-4
SUBTOTAL
TABLE # (1-4)
TAKE-OUT
TAX EXEMPT
TAX SHIFT 1-6
CLK IN/OUT
TIP (1-3)
TRANSFER CHK (1-4)
TRAY SUBTL
VALID
VOID ITEM
WASTE
FUNC.LIST#
X/TIME
STRING REPORT #
PARK ORDER
SERVE ORDER
KP ROUTING
SPLIT CHECK
ALPHA TEXT
NEW CHECK1-4
PRICE CHANGE
X X X X Exempt Tax (1-6)?
Non-Add # Compulsory?
Print on Receipt? On Journal?
Service of Negative Balance in X Only?
Hard Check Printer # (0-40)
Auto Check Management?
X Display Subtotal without Tax (added V2.00c)
X
X X Exempt Tax (1-6)?
KP Period Override (0=No Override)
Price Level (0-20)
X X X Exempt Tax (1-6)?
Non-Add# Compulsory?
X
X X X
X X Tip: Percentage/Amount
Tip: Open/Preset
Tip is Taxable by Rate (1-6)?
Must be Paid by Misc. Tender After Tip?
Tip Amount adds to Net & Gross Totals?
Charge Tip is Deducted from Cash?
X X
X X X Exempt Tax (1-6)?
Compulsory Before Tender?
Advance Consec# at Final Tender Only?
X
X X X X
X X X Affect on Projections?
X
X Allow Split Pricing?
Allow Decimal Input?
X X
X X
X X
X X Routing Period is: Stay down/Trans. Pop Up
X
X Permit Multiple Lines
Use Predefined Alpha Descriptor
Print in double
Do Not Print Alpha Text on Receipt
Do Not Print Alpha Text on Journal
Do Not allow Manual Alpha Entry
Allow On Screen Alpha Text Edit
X
X
SPS-2000 Program Manual v1.30 P Mode Programming
103
Function Key Programming Notes
Cash Key Program Note
COIN CHANGER PORT# (0-4)
Enter the number of the serial port to which the coin changer is attached.
Check Key Program Note
COIN CHANGER PORT# (0-4)
Enter the number of the serial port to which the coin changer is attached.
Currency Conversion Key Program Notes
RATE
The value of foreign currency can be express in two ways: foreign currency in US dollars, and the inverse, US dollars in foreign currency. For example a Canadian dollar may be worth $.70 US. The inverse of that value statement would be that a US dollar is worth $1.428571 Canadian dollars. Look for the rate expressed as US dollars in foreign currency (i.e. $1.428571 as in the example above) and enter that value in this field. Note: this field can contain 8 digits, with the decimal in any position. For example, you can enter 4 digits, the decimal, and four fractional digits.
CHANGE IN FOREIGN CURRENCY
Select whether any change from an over-tender is issued in foreign currency (Y) or home currency (N).
LINKED DRAWER # (0-3)
Select the drawer to be opened on foreign currency tender transactions.
Drive Thru/Eat In/Take Out Key Program Notes
KP PERIOD OVERRIDE (0=NO OVER)
Entry of a KP Group here allows kitchen printer routing based upon destination (Eat-in/Take-out/Drive thru). Selection of a KP Group here would also override KP Time Period programs. Enter 0 for no override.
KP Routing Key Program Note
ROUTING PERIOD IS
The KP ROUTING key is used to override KP Time Period control. For example, a restaurant might normally operate two kitchens at one time and one kitchen at other times. In case the volume of business changes, the manager might want to control the KP routing manually. Also, a single item, or large order might be required to be sent to a different printer than normal. Select STAYDOWN, TRANS
(transaction), POP UP or ITEM POP up operation.
104
P Mode Programming
SPS-2000 Program Manual v1.30
Miscellaneous Tend Key Program Notes
COIN CHANGER PORT# (0-4)
Enter the number of the serial port to which the coin changer is attached.
CONNECT EFT TERMINAL
Select Yes if DataTran is connected for integrated payment operations.
KEY IS
Select CREDIT, DEBIT or GIFT to indicate integrated payment function of the key.
CONNECT TO EFT ON RECD ACCT (V2.02b or later)
Allows a deposit to be taken by electronic payment methods. When used with the charge posting feature the user will now be able start a sale by authorizing for an amount on a credit card.
Modifier Key Program Notes
AFFECT DIGIT 1-14 OF PLU#
Preceding a PLU with a Size and/or Modifier key manipulates the PLU code assigned to the PLU key, causing a different PLU to be registered when the PLU key is pressed. Enter the digit of the PLU number you wish to be changed when using this key. (Digit #1 is the rightmost digit; digit #14 is the leftmost digit.)
VALUE OF AFFECTED DIGIT (0-9)
Enter the value you wish to be added in the digit position selected. For example, if you wish to affect
PLU digit #4 with a value of 1, then pressing this modifier key prior to the registration of PLU #17 will result in the registration of PLU #1017.
"%” Key Program Note
KEY IS "DO IT" DISCOUNT FUNCTION?
If a tender is short of the amount due, the operator has the option of accepting the amount tendered thus far as total payment for the transaction. Press the % key programmed with the "do it" function to finalize the sale with an amount still due. The amount due that is forgiven will be added to this key total.
SELECTIVE DISCOUNT?
If Yes, all other % key options are ignored and the key functions as a selective discount (coupon search) key. A promotion table with the “selective discount” type must be set. Coupons will be allowed for items listed on the promotion table and the coupon amount is set on the promotion table. The coupon is applied by entering the promotion table number and touching the % discount key. If the item is not on the promotion table list, the coupon will not be allowed.
ALLOW ONLY ONE DISCOUNT PER TRANS?
At V3.00w or later, also applies to item discounts, allowing only one discount per item.
Paid Order Recall Key Program Note
At V3.00g29, the option “Use EJ Recall” was added. When selected, this option will display a list of transactions on the left side of the screen. When a transaction is selected, the transaction detail is displayed in the right window of the screen.
SPS-2000 Program Manual v1.30 P Mode Programming
105
Print Key Program Note
AUTOMATICALLY PRINT MEAL ORDERLY
If yes the print key will send requistions in sequence by Group number, i.e. the first time touched, group 0 items will print, the second time touched, group 1 items will print, and so on.
Price Level (1-20) Program Note
PREVENT ZERO PRICE SALE
ALTERNATIVE PRICE LEVEL
If the Prevent Zero Price Sale option is set to YES, the ZERO AMOUNT message will display if you attempt to register a PLU with a zero price on the selected level. If Prevent Zero Price Sale and
Alternative Price Level are set to YES, the alternative price level will register if you attempt to register a
PLU is a zero price on the selected level.
Price Inquiry Program Note
Y=Stay Down/N=Pop Up
If a Stay Down, when a second PLU is registered after a stock or price inquiry, the result will be an inquiry on the second item. If Pop Up, when a second PLU is registered after a stock or price inquiry, the result will be the registration of the item rather than an inquiry for the item.
Recall Check Key Program Notes
DRIVE THRU FEATURE ENABLED?
Set to Yes if the tracking file is used for drive thru windows in fast food operations. In this case, the recall key will automatically recall the lowest tracking number from the appropriate tracking file. Note: see Store Check key programming. You must also set the appropriate Store Check key with the drive thru option enabled.
SCAN CHECK#
Allows use of scanner to enter check number. Note: At version 2.00x or later, if check numbers are assigned by register, the operator will be prompted to choose SCAN CHECK or OPEN A NEW CHECK when the RECALL CHECK key is touched.
Store Check Key Program Note
ENABLE DRIVE THROUGH OPTION
Set to Yes if the tracking file is used for fast food operations. In this case, the store key will automatically assign the next tracking number from the appropriate tracking file and store the transaction. Note: see the programming for the Recall Check key. You must also set the appropriate Recall Check key with the drive thru option enabled.
Waste Key Program Note
AFFECT ON PROJECTIONS
If Yes, the projection report will consider actual sale plus waste. If No, the projection report will only consider sales.
106
P Mode Programming
SPS-2000 Program Manual v1.30
Alpha Text Key Program Notes
If “USE PREDEFINED ALPHA DESCRIPTOR” option is set to YES, ten predefined options, as well as a “MANUAL REMOTE ENTRY” button are displayed from ALPHA TEXT function key. The
“MANUAL REMOTE ENTRY” button allows custom on-the-fly entries.
If “DO NOT ALLOW MANUAL” is selected, the user cannot enter on-the-fly instructions.
If “ALLOW ON SCREEN ALPHA TEXT MESSAGES” is selected, users can define the 10 pre-defined messages on-the-fly. In this manner, if a commonly entered PLU or instruction is not available, it can be created and reused as transactions are entered.
SPS-2000 Program Manual v1.30 P Mode Programming
107
System Options
Options are sorted by category to assist the programmer in finding a specific option. Options are referenced by number within each category for reference.
1. Select SYSTEM OPTION from the P-Mode menu to display the SYSTEM OPTION
PROGRAMMING selection screen.
2. Touch the System Option Programming area you wish to access.
3. The GENERAL FUNCTION OPTIONS are shown above as an example. Touch the page tabs at the top of the screen to view all of the options in each area.
108
P Mode Programming
SPS-2000 Program Manual v1.30
General Function Option Definitions
(1) MANAGER CONTROL (IN X-MODE):
Determine which of the listed functions require the key lock to be placed in the X position. Settings here do not affect transactions performed in the VOID key lock mode.
(2) ENFORCE EAT-IN/TAKE-OUT/DRIVE-THRU:
AT BEGIN OF SALE
You can enforce EAT-IN, TAKE-OUT, or DRIVE THRU either at the beginning of a sale, or before a tender by selecting Yes for either option.
(3) DEFAULT DESTINATION
You have the option of selecting a default destination selection: NONE, EAT-IN, TAKE-OUT, or
DRIVE-THRU.
(4) ROUNDING ON %
Choose rounding method for % (discount/surcharge): Up and .5, always up or always down.
(5) ROUNDING ON SPLIT PRICE/DECIMAL MULT
When calculations result in a fraction of a cent, you have the option of rounding UP AT .5 ($0.005 or greater rounds up; less than 0.005 rounds down) or you can choose to round any fractional calculation
ALWAYS UP or ALWAYS DOWN.
(6) CONSOLIDATE LIKE ITEMS
If Yes, like items are added, i.e. "2 COKES". If No, like items are on separate lines, i.e. "1 COKE" and
"1 COKE".
(7) HASH OPTIONS
Here you can define the meaning of HASH by selecting Yes or No to each item in the list of calculation options. See option #9 in “PLU Status Group” on page 83 to apply HASH status to PLUs assigned to a particular status group.
(8) ACTIVATE ROUNDING ON CASH
Choose to active the rounding system set in option #10 on CASH.
(9) ACTIVATE ROUNDING ON SBTL
Choose to active the rounding system set in option #10 on SUBTOTAL.
SPS-2000 Program Manual v1.30 P Mode Programming
109
(10) ROUNDING SYSTEM
Use these options to eliminate the use of small value coins (i.e. pennies). Rounding up or down occurs at subtotal or cash.
Select the ROUNDING SYSTEM field to display the ROUNDING SYSTEM PROGRAMMING
SCREEN where up to five ranges can be set. For example if you wish to eliminate pennies, the ranges could be set as:
#1 00-02 000 (.00-.02 rounds to .00)
#2 03-07 005 (.03-.07 rounds to .05)
#3 08-09 010 (.08-.09 rounds up to .10)
(11) GLOBAL ENTRY LIMIT (0-7, 0=NO LMT)
Select an entry limit that applies to all numeric entries (i.e. amounts for PLU entry, tenders, or multiplication.) The global entry limit will override any individually programmed limits.
(12) DIRECT MULTIPLICATION:
ENABLE
MAXIMUM DIGIT (1-5)
Direct multiplication allows you to enter a quantity and then press a preset key without using the
X/TIME key. You can enable direct multiplication here, and also determine the maximum number of digits for the multiplier.
(13) ALLOW PLU PRESET/HALO OVERRIDE
Override of a preset (entry of a price into a preset key) or override of a HALO (entry of a price greater than the PLUs high amount limit can be allowed. Note: In order to override, you must also set the flag for each individual PLU to allow override, and you must operate an employee with the authority level #18 set to allow override.
(14) SILENT KEY DEPRESSION
If Yes, the key depression tone is silenced. (Tone for errors is still active.)
(15) ALLOW OPEN ENTRY FOR SCALE PLUS
If Yes, amount entries are allowed for open scale PLUs.
(16) DEACTIVATE VOID MODE
Set to Yes to deactivate any activity in VOID mode.
(17) ALLOW PLU COPY BY RANGE
If yes, the COPY PLU command allow you to copy statuses from a single PLU to a range of PLUs. If no, you can only copy from a single PLU to another individual PLU. See “File Management” on page 156 to copy PLUs.
(18) ALLOW POST TENDERING
Choose Yes to allow tendering after the sale has been finalized, for the purpose of computing change
(19) EMPLOYEE: POP UP/STAY DOWN
Choose Yes to automatically sign off at the completion of a transaction. Choose No to register sales continuously for the same employee.
110
P Mode Programming
SPS-2000 Program Manual v1.30
(20) EMPLOYEE SIGN ON
Select the method you wish to use when signing on to operate the SPS-2000: PUSH BUTTON,
OPERATING CODE, EMPLOYEE# or FINGERPRINT . See “Employee Sign-On/Sign-Off” in the
SPS-2000 Operation Manual for more information.
(21) QTY LIMIT FOR X/TIME KEY
Determine the maximum quantity that can be used for a multiplier.
(22) ERROR BUZZER IS SPOT
Select YES for a momentary error tone; select NO for a continuous error tone that must be cleared.
(23) GUEST CHECK BALANCE HALO (0=NO LIMIT)
You can place a high amount limit on the balance that is stored in a tracking file.
(24-33) EMPLOYEE # LINKED "EMPOYEE1" KEY
The 10 push button employee functions (codes 41-50) can be used to sign on specific employees. The specific employee for each key is assigned here.
(34) ALLOW NOT FOUND PLU
If yes, when a PLU number is entered (or scanned) that is not in the PLU file, the operator can enter the item price and complete the transaction.
(35) SET DEFAULT SEAT# TO 1
If yes, each item that does not receive a seat # will be assigned the default seat number of 1. Using a seat number system assists prep staff in assembling orders correctly and facilitates payment of separate parts of a check.
(36) ENTER TIME FOR TRANSACTION VOID
If yes, you must enter a time before beginning a transaction void. This allows sales by time reports to be adjusted appropriately.
(37) SCREEN SAVER (MINUTES)
Enter the number of minutes (1-99, cannot be set to zero) before an inactive screen will automatically display. Press any key to refresh the screen.
(38) ALLOW THE PRESS (NEWSPAPER) CODE PLU
Feature is not used.
(39) ALLOW MULTIPLE MULTIPLICATION
Yes allows multiple multiplication, for example, 2 X/TIME, 3 X/TIME, ITEM. Note that multiple multiplication overrides split pricing.
(40) ALLOW TAX SHIFT BY TAKE OUT
Feature is not used.
(41) TAX SHIFT:
Choose Item Pop Up or Trans. Pop Up. Tax shift key(s) can shift tax for the next item entered, or for a subsequent entries in the same transaction.
SPS-2000 Program Manual v1.30 P Mode Programming
111
(42) BASE CURRENCY
Set for local currency.
(43) ALLOW CLERK INTERRUPT
If allowed, a new clerk can be signed on in the middle of a transaction. In this circumstance, the initial transaction is suspended. When the interrupt transaction is completed, the suspended transaction can be continued. You must set option #45 in this program, “ALLOW CLERK CHANGE WITHOUT SIGN-
OFF” to YES and set the S-Mode System Option, “REG# HOLDS CLERK INTERRUPT DATA” to activate this feature.
CAUTION: If used, this feature may cause operator confusion. Suspended transactions may appear to
“disappear”, when in fact; the original clerk must sign on to recall the suspended transaction.
(44) ALLOW FLOATING CLERK
With ‘NO’ of this option, the employee must reopen his or her interrupted order on the register which he/she used before. If you set to YES, employee is allowed to open interrupted order at any register.
(45) ALLOW CLERK CHANGE WITHOUT SIGN-OFF
If YES, new clerk sign on is allowed without previously signing off the current employee. Must be set to
YES if clerk interrupt is implemented.
(46) SKIP IN NOT FOUND PLU REGISTRATION
GROUP LINK #1
DESCRIPTOR
The “Not Found PLU” sequence asks for LINK STATUS and LINK GROUP. Select here if you wish to bypass these entries.
(47) RECEIPT STATUS ON OPERATOR DISPLAY
Choose Yes to display the receipt on/off status on the operator display. Receipt-on displays as "Ron"; receipt-off displays as "ROff".
(48) CARD READER ENABLE
Required for use of employee cards.
(49) ALLOW SALES FOR 0 STOCK ITEMS
If Yes, sale of items with zero stock is allowed.
(50) DATE OF BIRTH ENTRY COMPULSORY
If Yes, date of birth for age verification items must be entered at prompt. Operator may press escape to sell items when set to N.
(51) CHECK DIGIT IS SENT FROM BCR
Setting needs to match your scanner setting. If scanner is set to read check digit, this option must be Yes.
(52) DISPLAY POPUP ON DESTINATION CHANGE
If YES, a pop-up window will display when a destination key (EAT-IN, TAKE OUT, DRIVE THRU) is pressed.
112
P Mode Programming
SPS-2000 Program Manual v1.30
(53) USE DEST. OPTION
If “The Same For All Reg”, all registers will have the same settings for option #2 (Enforce Destination) and option #3 (Default Destination). If “Register Separately”, settings for options #2 and #3 will not download and must be programmed separately. For example, if a restaurant has both counter and drive thru service, you would select “Resister Separately” so that counter registers would prompt destination and drive thru registers would not prompt destination entry.
(54) ONLY DISPLAY SCREEN WHICH HAS PLU ON SELECT PLU PROGRAM
When programming PLUs, the SELECT PLU screen allows you to view and select PLUs as they are placed on keylinks. If the YES option is selected here, keylinks that do not display any PLUs are not available to view.
(55) DISPLAY MESSAGE ON POLE (added V2.00o)
A programmable 25-character message can be displayed on an optional pole display. Choose NONE,
MESSAGE to display the programmable message, or TIME to display the time. Select P-Mode,
MESSAGES, POLE DISPLAY MESSAGE to program the message
(56) POLE DISPLAY MESSAGE DIRECTION (added V2.00o)
Choose the direction you wish the pole display message to scroll: LEFT, RIGHT or BOTH to view the message bouncing back and forth.
(57) ALLOW SALES UNDER MINIMUM STOCK (added V2.00s)
When STOCK status is assigned to a PLU (see PLU STATUS GROUP option #16), a warning “BELOW
MINIMUM STOCK” will display when if the PLU is registered and stock is below the minimum level.
(58) SCREEN SAVER TYPE (added V2.01n)
Select FLOATING or ROTATE. Floating requires a single image, named “logo.jpg” which will float in a pattern across the screen. Rotate allows multiple images to display in sequence. Up to 50 images are available and must be named “logo##.jpg” where ## is the image number: 01 through 50.
(59) SHOW REAL TIME STOCK ON KBD (added V2.01n)
If Yes, the current stock counter will be displayed on the PLU button located on a Key Link. Stock counters may be slightly different if the items are registered at other terminals in a network. The stock counter is updated after the key is touched.
(60) SUPPRESS SELECTIVE DISCOUNT ERROR MESSAGE (added V2.01n)
If selective discount (coupon search) is used, an error will result if a discount is attempted for an item that is not registered in the transaction. You can suppress that error message here. (To set up selective discounts, see “Promotion Table” on page 155 and also see the “"%” Key Program Note” on page 105.)
(61) PRINT POWER FAIL COUNT WHEN POWER FAIL OCCURS (added V2.02b)
Each time the register powers on it will print a chit to the programmed receipt printer stating there was a power fail with the time, date, register number. For example:
POWER FAIL!!
TIME: 16:53 DATE : 7/10/2007
POWER FAIL COUNT : 2
Also added a way to reset this count. In REG mode press [X/TIME]; the number of POWER FAILS displays and the user can press [RESET] to set number of power fails to 0. The manager password will be needed to reset the power fail count.
SPS-2000 Program Manual v1.30 P Mode Programming
113
(62) USE STOCK LINK PLU ON PLU PGM (added V2.03j)
Choose:
STOCK LINK PLU - The linked PLU is the stock link PLU.
KP DESCRIPTOR PLU - The linked PLU's descriptor is used for the KP descriptor instead of its own descriptor. This allows for a secondary PLU descriptor to print on the KP. (For example, this can be used to print Spanish in the kitchen.)
LINK PLU - The linked PLU is used the link PLU instead of LINK PLU in PLU status group.
(63) DO NOT USE ERROR BUZZER (added V3.00g)
(64) ACTIVATE ROUNDING ON MISC TEND
Employ rounding (as defined in option #10 above) to sales tendered by a miscellaneous tenter key.
(65) PLU STATUS FOR LABWARE CONDIMENT
For later use with Labware application.
(66) PLU STATUS FOR LABWARE COOK LINK
For later use with Labware application.
(67) DO NOT ALLOW VOID DISCOUNT IN SALE
(Option added at version 3.00g30) Choose YES here when when discounts are set to net item totals. If a discount is applied, and later voided, balancing issues may result.
Tax Option Definitions
(1) TAX ROUNDING FACTOR
When tax calculations result in a fraction of a cent, you have the option of rounding UP AT .5 ($0.005 or greater rounds up; less than 0.005 rounds down) or you can choose to round any fractional calculation
ALWAYS UP or ALWAYS DOWN.
(2) VAT SUBTRACTED FROM INDIV PLU TTLS
Choose Yes to subtract the VAT tax amount from the PLU totals on the PLU report. If No, the PLU report total reflects the items price and the value added tax.
(3) TAX EXEMPT QTY (CANADA DONUT)
Enter the quantity at which you wish tax to be exempted. For example if set at 12, registration of PLUs reported to status groups with eligibility for Canadian donut law selected will charge tax until the quantity with the transaction reaches 12. When 12 or more are registered, all will be sold without tax. To use this feature, you must also set eligibility status for the PLU. See option #42 is “PLU Status Group” on page
83.
(4) PRINT TAXABLE AMOUNTS ON R/J
Choose Yes to print the tax eligible subtotals for each tax on the receipt and/or journal, if printed.
(5) TAXABLE STATUS INDICATORS:
DISPLAY
In the default condition (Y), tax eligibility indicators, i.e.
T
X
1 display on the screen and print on printers adjacent to the item. Choose No to selectively remove the indicators from the display and/or print.
114
P Mode Programming
SPS-2000 Program Manual v1.30
(6) PRINT TAX AMOUNTS AT TENDER
When set to No, the tax charged will not print on the receipt (TAX1, TAX2, etc.)
(7) PRINT VAT TAX AMT SEPARATELY
If there are multiple value added taxes, choose Yes to print tax amounts separately for each tax, rather than a single tax total.
(8) TAX PRINT: COMBINED/ ITEMIZED
If No, each tax amount will print separately. If Yes, one TAX total will print.
(9) PRINT TAX EXEMPT DESCRIPTOR/TTLS
If Yes, a tax-exempt total will print on the receipt.
(10) PRINT SUBTOTAL WITHOUT TAX
If Yes, the merchandise subtotal does not include tax.
(11) DO NOT SHOW FOOD STAMP INDICATOR
In the default condition (Y), the food stamp indicator,
F
S
displays on the screen and prints on printers adjacent to the item. Choose No to remove the indicator from the display and print.
(12) PRINT TAX ON VAT
If Yes, prints breakout tax amount on VAT tax sales receipts.
(13) IS MNM TAXABLE
If Yes, mix and match discounts are taxable, resulting in tax being applied to the net sale amount, rather than the gross amount.
Cash Drawer Option Definitions
(1) ALLOW SALES WITH DRAWER OPEN
Choose Yes to force the drawer to be closed before registrations are allowed.
(2) C-I-D AMOUNT LIMIT
Set the maximum amount of cash in drawer before an error tone and message display. The error can be cleared and continued sales are allowed, however the warning continues to sound at the completion of each transaction, until cash is removed from the drawer. Set the amount to 0 to disable the cash in drawer limit warning.
(3) OPEN DRAWER DURING X-REPORTS
Choose Yes to open the drawer at the completion of any X report.
(4) OPEN DRAWER DURING Z-REPORTS
Choose Yes to open the drawer at the completion of any Z report.
(5) ACTIVATE OPEN DRAWER ALARM
If Yes, an error tone sounds when the cash drawer remains open the length of time specified in option #6 below.
(6) OPEN DRAWER ALARM TIME
Enter length of time the drawer may be open (in seconds) before the open drawer alarm sounds.
(7) OPEN REMOTE DRAWER
Always set to NO. (Will allow opening a drawer on a remote register.)
SPS-2000 Program Manual v1.30 P Mode Programming
115
(8) RESET DRAWER ASSIGNMENT AT
Choose NEVER, Z1 FINANCIAL, or Z1 CASHIER. Allows resetting of drawer assignments to rotate different employees to a drawer.
(9) OPEN DRAWER DURING CASH DECLARATION
When this option is set to Yes, the drawer will open at the start of the CASH DECLARATION procedure.
Training Mode Option Definitions
(1) OPEN DRAWER IN TRAIN MODE
Choose Yes to open the appropriate cash drawer during training operations.
(2) TRAINING EMPLOYEE FILE #
Choose the employee file # that is updated with training activity.
(3) ALLOW REAR DISPLAY IN TRAINING
Choose Yes to activate the rear display during training activity. If No, the rear display indicates
CLOSED during training.
(4) SEND ORDER TO KP/V IN TRAINING
Choose Yes to send orders to the kitchen printer and/or kitchen video during training.
(5) PRINT JOURNALS IN TRAINING
Choose Yes to print (or update, in the case of an electronic journal) the journal in training.
(6) PRINT RECEIPTS IN TRAINING
Choose Yes to print receipts (if receipts are normally printed) during training.
(7) PRINT "TRAINING"
If receipts are printed they are normally printed with the message TRAINING and the message
'***TRAINING***" displays on the operator screen. Choose No to remove these messages.
(8) STOCK IS DEDUCTED IN TRAINING MODE
Default is NO. Choose YES if you wish stock to affect inventory levels for training mode activity.
Level/Modifier Option Definitions
(1) DEFAULT PRICE LEVEL
If price levels are pop-up (see option #4), enter the level you wish to return to after an entry in a different level.
(2) PRICE LEVEL
Choose STAY DOWN, TRANS POP UP, or ITEM POP UP.
STAY DOWN: Once chosen, will remain active until the next choice.
ITEM POP UP: Choice remains active for the next PLU only, and then returns to the default.
TRANS POP UP: Choice remains active for the remainder of the transaction, then returns to the default with the transaction is finalized.
116
P Mode Programming
SPS-2000 Program Manual v1.30
(3) PLU MOD KEYS
Choose STAY DOWN, TRANS POP UP, or ITEM POP UP.
STAY DOWN: Once chosen, will remain active until the next choice.
ITEM POP UP: Choice remains active for the next PLU only, and then returns to the default.
TRANS POP UP: Choice remains active for the remainder of the transaction, then returns to the default with the transaction is finalized.
(4) APPLY MODIFIER TO CODE ENTRY PLUS
If Yes, PLU modifier keys may be used with both keyboard PLU keys and code entry PLUs.
(5) MODIFIER OVERWRITES PREV MODIFIER
If Yes, only the last modifier entry will affect the PLU number. Use this setting when a PLU is modified only once, i.e. small/med/large. If No, several modifiers affecting different digit positions could be entered and then affect the PLU registered. For example, size, crust type, and/or toppings could be indicated on pizza items.
(6) USE MODIFIER HISTORY
If Yes, multiple modifiers will display in the message line before a main PLU is registered.
(7) USE CLERK’S PRICE SHIFT LEVEL
If Yes, the price level will be determined by the “Default Price Level” setting in the Employee program.
(8) EXIT TO MAIN SCREEN AT DONE KEY ONCE
Option is not used.
(9) DEFAULT SCREEN (0-200)
Select the keylink number that will appear as default in REG mode. (“0” is the main screen.)
(10) EXIT TO MAIN SCREEN AT FINALIZATON
If Yes, after finalization the default screen (identified in option #9 above) will display.
(11) USE CLERK’S DEFAULT SCREEN LEVEL
If Yes, the “Default Screen Level” setting in the Employee program will display after log on.
Tracking File Option Definitions
(1) AUTOMATIC TRANSFER CHECK
If Yes, the check will be assigned to the last person who posted to the check.
(2) CHECKS PAID SLIP IS STUB
If Yes, the PRINT CHECK function produces a guest check with totals only, without item detail.
(3) PRINT GUEST CHECK
When Yes, the guest check will print when the order is paid.
(4) SELECT HELD ITEMS ON RECALL
Items may be "held" to temporarily postpone kitchen printing (or display). If Yes, held items are automatically selected when a check is recalled so they may be sent to the appropriate printers/screens.
(5) WARN IF HELD ITEMS AT FINALIZE
If a check with held items is paid, a warning will display.
SPS-2000 Program Manual v1.30 P Mode Programming
117
(6) TRACK 2 HOLD CLOSED CHKS FM TRK 1
(7) TRACK 4 HOLD CLOSED CHKS FM TRK 3
The SPS-2000 system does not feature a standard closed check file. However, if you do not require all four of the available check files, unused tracking files can be utilized to store closed checks as indicated in options #9 & #10. (See "Memory Allocation " in S-Mode Programming.)
(8) STARTING CHECK#
For each tracking file that you are using, if you are automatically assigning tracking numbers, you can enter the first number of the tracking file to be issued after the check number is reset.
(9) CHECK# LIMIT (0=NO LIMIT)
Sets the upper limit for the check #. If set to"10", once check #10 is used, the next check will be the starting check number.
(10) RESET CHECK #1)
(11) RESET CHECK #1)
(12) RESET CHECK #1)
(13) RESET CHECK #1)
Select when you wish the check number to reset: Z1 FINANCIAL, Z1 OPEN CHECK or NEVER.
(14) DISABLE CHECK PRINT ON RECEIPT
If Yes, at tender the guest check will not print on the receipt printer.
(15) CHECK PRINTER # (0-40)
Identify the printer number of the guest check printer.
(16) PRINT BARCODE ON CHECK
If yes, automatically generates barcode based upon the check number. The check can be recalled by scanning the barcode. The barcode type printed is type 128.
(17) USE ALPHA CHECK NUMBER
If yes, a customer name can be associated with the order. A keyboard automatically displays for input.
The check can be recalled by name or from the check list.
(18) CHECK OPEN WITH MCR (requires 2.00s or later)
Allows opening of tracking file by MCR. Select the tracking file to be used.
(19) READ (requires 2.00s or later)
If opening check by MCR, select TRACK 1 or TRACK 2.
(20) COLUMN OF NUMBER/START/DIGIT (requires 2.00s or later)
If opening check by MCR, Enter the number of the column that the Card number starts and enter the number of digits to be read for the Card number.
(21-24) CHECK TRACKING TYPE FOR TRACK (1-4) (requires 2.01n or later)
Choose NORMAL for restaurant-style check tracking or DEPOSIT or charge posting where partial payment and credit balances are allowed (Use Received on Account key to post payments.)
(25) SEPARATE CHECK DETAILS BY DATE (requires 2.01n or later)
If check tracking type is “DEPOSIT”, setting to yes will list items sorted by sale date.
(26) PRINT CHECK BEFORE TENDER COMPULSORY (requires 2.01n or later)
If yes, a check must be printed before payment is tendered.
118
P Mode Programming
SPS-2000 Program Manual v1.30
(27) PRINT DELIVERY INFO ON GUEST CHECK (requires 2.01n or later)
If yes, delivery information (name, address, etc., from the customer delivery record) will print on the check.
(28) PREVENT SALE OVER DEPOSIT AMOUNT (requires 2.01n or later)
If check tracking type is “DEPOSIT”, a credit balance must be maintained. Items cannot be sold that would cause the check balance to exceed zero.
(29) PRINT BALANCE ON CHECK TABLES (requires 2.02n or later)
(30) WAITING TIME FOR ORDER (requires 3.00w or later)
You can set an alarm to warn that a check is open but not serviced. Set the time in minutes that a check can be open before the alarm sounds. Set to zero for no alarm.
Kitchen Printing/Video Option Definitions
(1) PRINT AT KP:
TOTAL AMOUNT LINE
PRINT SEAT #
TRANSACTION VOID ITEMS
PLU PRICE
BITMAT
NUMBER OF ITEMS
NUMBER OF TOTAL ITEMS
PLU DESCRIPTOR IN KOREAN (requires v3.00w or later)
You can determine the content of each kitchen printer chit. For each item listed, select No to remove print from the kitchen printer.
Note: the TOTAL AMOUNT line includes a line for TOTAL and TAX.
(2) ENABLE SORT KP BY KP GROUP #
Use this option to create "priority print". For example, if you wish to group appetizers at the beginning of the chit, then entrees next, place appetizers in a kitchen printer group (see "PLU Status Group" on page
83) with a lower numeric value than the value of the group to which entrees are reported.
(3) # LINE FEED AT BEGIN OF KP PRINT
Enter the number of lines you wish to feed before beginning kitchen printer print.
(4) # LINE FEED AT END OF KP PRINT
Enter the number of lines you wish to feed after beginning kitchen printer print.
(5) COMBINE LIKE ITEMS ON KP OR KVS
If Yes, for example, if two hamburgers are entered and sent to the printer, they will print as "2
HAMBURGERS", rather than
"1 HAMBURGER" and "1 HAMBURGER" on a second line. If condiments are entered, they will be separated and printed below the items.
(6) SEND ORDER TO KP AT SUBTOTAL
Choose Yes if you wish to print when the subtotal key is pressed, instead of when the sale is finalized.
SPS-2000 Program Manual v1.30 P Mode Programming
119
(7) SEND ORDER TO KVS ON SUBTOTAL
Choose Yes if you wish to send items to the KVS when the subtotal key is pressed, instead of when the sale is finalized.
(8) PRINT VOIDED ORDERS AT KP OR KVS
If No, then transaction void orders will not print or display at the appropriate printer/screen.
(9) KP IS: REAL TIME/ BATCH
Real time means that each item will print at the printer when the next item is entered (one item delay).
Batch means that the entire order will print when the order is finalized.
(10) KVS IS: REAL TIME / BATCH
Real time means that each item will display at the screen when the next item is entered (one item delay).
Batch means that the entire order will display when the order is finalized.
(11) USE KP ROUTER
Choose from "THE SAME FOR ALL REG" if all registers in the IRC system use the same kitchen printer routing or "REGISTER SEPARATELY" if different registers have different routing. See "Printer
& KV Routing" on page 154.
(12) KP ORDER#
Choose from "COMBINATION OF REG#&CONS#" or "GLOBAL ORDER#".
(13) DISPLAY KP TIME PERIOD#
You can program four different KP routings by time period (See "Printer & KV Routing" on page 154).
If Yes, the operator display will which of KP routing periods is active in the lower left portion of the display.
(14) DISPLAY KP ORDER #
Choose Yes if you wish to display the order # in the lower left portion of the operator screen when the order is finalized.
(15) SEPARATE KP BY KP GROUP #
Choose Yes if you wish to separate items from different KP Groups and issue separate kitchen printer tickets for items from each KP Group.
(16) SEPARATE KP BY KP ITEM
Choose Yes to produce a separate requisition for each main item.
(17) SORT KP BY SEAT #
If seat # system is used, will sort kitchen printer orders by seat #, for example:
Seat #1
01 Eggs
01 Coffee
Cream
-----------------
Seat #2
01 Eggs
01 Orange Juice
(18) SEND ALPHA TEXT TO KP/KV (V2.00a or later)
Choose Yes to send messages entered by the ALPHA TEXT key to the kitchen printer or kitchen video.
120
P Mode Programming
SPS-2000 Program Manual v1.30
(19) PRINT DELIVERY INFO. ON KP (requires 2.01n or later)
If yes, delivery information (name, address, etc., from the customer delivery record) will print on the kitchen printer.
(20) USE KV REFRESH (requires 3.00a or later)
If yes, will delete all items from the KVS and re-display them when a condiment is inserted or a void is performed.
Validation/Subtotal Print Option Definitions
NOTE: To validate, you must attach a printer with validation capability to each register that will validate.
Use option #7 to identify the port to which the printer is attached.
(1) VALIDATION AMT: TOTAL / TENDER
For sale validation, you can select either the amount of the sale or the amount of the tender as the amount to print on the validation.
(2) CHK VALID AMT: TTL / TEND
For check sale validation, you can select either the amount of the sale or the amount of the tender as the amount to print on the validation.
(3) ACTIVATE VALIDATION SENSOR
The printer must be equipped with validation option and sensor.
(4) ALLOW MULTIPLE VALIDATIONS
If Yes, the validation can be done more than once.
(5) PRINT VALIDATION MESSAGE
See "Messages" on page 145 to program a message of up to three lines.
(6) PRINT SBTL WHEN SBTL KEY PRESSED
If Yes, the receipt (if applicable) will print the subtotal at the point in the transaction when the key was pressed.
(7) VALIDATION PORT# (0-6)
Indicate the port on the register that is connected to the validation printer.
(8) DISPLAY RUNNING SUBTL ON POLE
Allows the pole display to show a running subtotal as items are entered.
SPS-2000 Program Manual v1.30 P Mode Programming
121
General Printing Option Definitions
(1) PRINT ON RECEIPT:
ITEMS BY GROUP
DATE
TIME
PREAMBLE/POSTAMBLE
Determine the content of each receipt by selecting Yes or No for each item.
(2) RECEIPT FEED LINES AFTER PRINT
Enter the number of lines you wish to feed after each receipt is printed. (Makes chit larger.)
(3) LNES AFTER PREAMBLE
Enter the number of lines you wish to feed after the preamble and before the first receipt print line.
(4) LNES BEFORE POSTAMBLE
Enter the number of lines you wish to after the last receipt line and before the postamble.
(5) BUFFERED RECEIPT: STUB / FULL
A stub receipt contains only the total, tender and transaction information. A full receipt includes item detail.
(6) PRINT RECEIPT WHEN SIGNING ON/OFF
If Yes, a receipt is printed whenever an employee signs off or on.
(7) PRINT RECEIPT WHEN CLOCKING IN/OUT
If Yes, a receipt is printed whenever an employee clocks in or out.
(8) CONDENSE TRAY SBTL RECEIPTS
Prints each separate tray subtotal receipt without preamble/postamble.
(9) DETAIL: REAL TIME / BATCH
Prints detail (journal) on journal printer (or updates electronic journal) line by line (real time) or at transaction finalization (batch).
(10) PRINT PLU CODE WITH DESCRIPTOR
If Yes, both the PLU# and descriptor will print when a PLU is registered.
(11) TRANSACTION # IS RANDOM NUMBER
If Yes, the transaction # is generated randomly, rather than sequentially.
(12) HOME CURRENCY SYMBOL ($=DEFAULT)
Select the currency symbol for display, receipts, etc.
(13-17) CURRENCY (1-5) SYMBOL
Select the currency symbols to be used for the currency conversion function keys.
(18) PRINT TENDER ON RECEIPT
If No, the tender will not print on the receipt.
(19) DISABLE LINE FIND ON SLIP PRINTER
122
P Mode Programming
SPS-2000 Program Manual v1.30
If an optional slip printer is used for hard check operation, set this flag to Yes to print without automatic line feed.
(20) DATE PRINT
Choose format: MMDDYY; DDMMYY; YYMMDD
(21) GUEST CHECK PREAMBLE/POSTAMBLE
Select NONE, GUEST CHECK LOGO MESSAGE, or LOGO MESSAGE to determine the content of the guest check preamble/postamble
(22) PRINT RECEIPT AUTOMATICALLY
Choose Yes to generate a receipt automatically when transactions are tendered.
(23) PRINT RECEIPT AFTER TIME CLOCK EDIT
If Yes, a receipt is printed whenever an employee's time is edited.
If Yes, a counter of the number of times the guest check has been printed appears on the check.
(24) PRINT IN DOUBLE
TOTAL
TENDER
CHANGE
You can choose double-width printing for Total, Tender, Change, and/or Order #
(25) PRINT RCPT AUTOMATIC. IN VOID MODE
If Yes, a receipt will automatically be printed for transactions in VOID mode.
(26) PRINT NUMBER OF ITEMS ON RECEIPT
If Yes, a count of the number of items will appear on each receipt.
(27) ALLOW MULTIPLE RECEIPTS
If Yes, more than one copy of the receipt can be issued after the sale.
(28) PRINT GUEST CHK PRINT COUNT ON GC
If Yes, the check will print a counter of how many times the guest check has been printed.
(29) ITEMS ON RECEIPT IS # OF ITEMS PRINTED ONLY
If Yes, the item count on the receipt will include only items printed on the receipt, and will not include items programmed not to print on the receipt.
(30) COPY OF EFT RECEIPT
Indicate the number of copies of the credit card transaction receipt to be printed.
(31) PRINT TIP ON EFT RECEIPT
If Yes, prints tip line on credit card receipt.
(32) MASK NUMBER ON ALL CREDIT DRAFTS
If Yes, only the last 4-digits of the card number are printed.
(33) NOT PRINT AN ALPHA TEXT MESSAGES ON THE GUEST CHECK/RECEIPT
If Yes, alpha text messages will not print on guest checks or receipts.
SPS-2000 Program Manual v1.30 P Mode Programming
123
(34) PRE LOGO IMAGE# ON RECEIPT
Select one of the loaded bit map images.
(35) POST LOGO IMAGE# ON RECEIPT
Select one of the loaded bit map images.
(36) PRE LOGO Image ON GUEST CHECK
Select one of the loaded bit map images.
(37) POST LOGO Image ON GUEST CHECK
Select one of the loaded bit map images.
(38) PRINT ERROR CORRECT/VOID ON EJ & PRINTER
When set to YES, error corrects and item voids will still be resent on the EJ.
(39) PRINT DELIVERY INFO. ON RECEIPT (requires 2.01n or later)
If yes, delivery information (name, address, etc., from the customer delivery record) will print on the receipt.
(40) RESET PREVIOUS ITEM COUNTER FOR RECALL (requires 2.01n or later)
If yes, the guest check item counter will reset upon check recall, the counter will only accumulate the total of items at each posting.
(41) PRINT PROMTION AFTER TRIGGER PLU (requires 2.02b or later)
(42) ENABLE BARCODE PRINTING (requires 2.02b or later)
(43) NO SIGNATURE SLIP IF TRANSACTION TOTAL IS LESS THAN (requires 2.03j or later)
When the MISC TEND transaction is less than XX.XX the merchant copy of the EFT transaction will not print the signature line.
124
P Mode Programming
SPS-2000 Program Manual v1.30
Report Printing Option Definitions
(1) ZERO SKIP
TIME PERIOD REPORT
ALL OTHER REPORTS WHEN PRINTING
Choose whether to print or skip totals with a zero value on each of the listed reports.
(2) PRINT % OF SALES ON PLU REPORT
If Yes, the percentage of each PLUs sales is calculated and printed on the PLU report.
(3) PRINT LINKED GROUPS ON PLU REPORT
If Yes, each item on the PLU report will also print the group number of each group to which the PLU is linked.
(4) PROMO/WASTE TOTALS ON PLU RPT
If Yes, the promo and waste detail for each PLU will print on the PLU report.
(5) INDIV ITEM USAGE QTY ON PLU RPT
If Yes, PLU report is adjusted to reflect promo/waste totals.
(6) COUNT ON TIME RPT IS
Select Customer or Guest.
(7) USE FUNCTION KEY DESCRIPTOR IN RPT
Financial/employee reports include totals for some function keys. The descriptor that appears on the report can be the programmed function key descriptor or can be the report descriptor (see "Messages" on page 145.)
(8) PRINT MIN.STK RPT AFTER FINAN. RPT
If Yes, an X1 minimum stock report will automatically follow any financial X or Z report.
(9) PRINT GRAND TOTAL ON FINANCIAL RPT
If Yes, the Grand Total will print on the Financial report.
(10) PRT GROUPS BY EMPLOYEE RPT
AFTER EMPLOYEE REPORT
If Yes, the Groups by Employee report will automatically print after the Employee report.
(11) PRINT INDIV PLUS ON FOOD COST RPT
If Yes, Food Cost report will print out costs for each individual PLU. If, No will print a summary.
(12) AUTO CUT STRING REPORT
If Yes, auto-cutting printers will auto cut between reports.
(13) PRT CLK IN/OUT ON TIME KEEPING RPT
If Yes, each time clock entry will print out on the Time Keeping report. If No, only total hours will print.
(14) PRINT PLU PROFIT ON PLU COST REPORT
If Yes, the PLU total cost, profit, and profit ratio will print on the PLU Cost Report. Each PLU cost must be entered the price level identified in the Report Option program.
SPS-2000 Program Manual v1.30 P Mode Programming
125
(15) DO NOT PRINT HASH SYMBOL (V2.02n or later)
Report Option Definitions
(1) ONLY TTL ON PRODUCT MIX GROUP RPT
If Yes, skips sales by time period on the Product Mix report.
(2) ONLY ITEMS WITH ACTUAL INV ENTRY
Affects the Inventory report (reporting ingredients from the recipe system). If Yes, the Inventory report will report only those items where actual inventory has been entered through the EDIT INVENTORY
ITEM function of X-mode.
(3) CASH DECLARATION COMPULSORY
If Yes, you must declare the amount of cash before taking any report. This encourages accurate reporting and over/short amounts are calculated and printed.
(4) ENFORCE ACTUAL INVENTORY BEFORE Z1
If Yes, you must enter actual inventory before running an inventory report.
(5) RETAIN ACTUAL INV ENTRIES IN X1
If Yes, actual inventory entries are retained after an X Inventory report. Use No, if you are doing inventory spot-checks on selected items.
(6) RESET PLU REPORT AT INVENTORY Z1?
If Yes, a Z1 PLU report will automatically be generated when an Inventory Z1 is taken.
(7) RESET INVENTORY REPORT AT PLU Z1?
If Yes, an Inventory Z1 will automatically be generated when a Z1 PLU report is taken.
(8) TIME KEEPING: MINUTES / 100UNITS
Determine whether hours worked are recorded and calculated in minutes or decimal units of an hour.
(9) OMIT TAX TOTALS FROM NET SALES GT
Choose Yes, to omit tax totals from the Net Sales Grand total on the financial report.
(10) ALLOW Z OF OPEN CHECK REPORTS
Choose Yes, to allow a Z open check report.
(11) CONFIRM BEFORE TOTALS RESET ON Z
If Yes, a message will display before resetting the totals on the report.
(12) RESET AFTER FINANCIAL Z REPORT:
GROSS SALE GT
NET SALES GT
NEGATIVE SALES GT
Select which totals and counters are reset when a Z1 Financial report is executed.
(13) VOID MODE TOTALS ADD TO GRAND TTLS
If Yes, activity in the VOID key lock position adds to grand totals.
(14) ALLOW Z WITH OPEN ORDERS
126
P Mode Programming
SPS-2000 Program Manual v1.30
If No, any Z report is disabled until open orders are closed.
(15) ALLOW Z STOCK REPORT
If Yes, resetting the Stock report is allowed.
(16) ALLOW Z1 TIME KEEPING REPORT
WHEN EMPLOYEES ARE CLOCKED IN
If Yes, the time keeping report can be run when employees are clocked in.
(17) AVG. GST ON FIN IS FROM GST
If No, the AVG/GST (average sale per guest or customer) is calculated from customer count, if Yes, is calculated from guest count from GUEST key use.
(18) ALLOW Z WITH OPEN CLERKS
If Yes, Z reports are allowed with interrupted orders when clerk interrupt is used.
(19) MAKE IRC REPORT IN DEFAULT?
When Yes, any report taken will be automatically an IRC report. All registers in the range identified in S-
Mode options will be included.
(20) MGR REQUIRED FOR IRC SETTING?
When Yes, the manager password must be entered to change IRC report settings.
(21) CLEAR GLOBAL ORDER# AFTER Z1 FINAN?
If Yes, the global order number counter will reset to zero after a Z1 Financial report.
(22) EXCLUDE TAX ON TIME PERIOD REPORT? (added V2.00c)
The Time period report feeds the totals for the SALES & LABOR % report. This options allows the totals to be without tax.
(23) PLU COST PRICE LEVEL (0-20)
If you wish to report PLU cost, profit, and profit ratio, select the PLU Price Level where the PLU cost will be entered
(24) ENABLE INVENTORY REPORTING WITHOUT ACTUAL INVENTORY INPUT (V2.02b or later)
If YES, the SPS-2000 will use the theoretical values as actual inventory if inventory is not activated through the EDIT INVENTORY ITEM function of X-mode.
Time Keeping Option Definitions
(1) OVERTIME HOUR IS USED FOR
Select Day or Week for overtime hours.
(2) HOURS PER OVERTIME STARTS
Enter the number of hours that must be worked per day or week before overtime starts. For example, if field #1 is day, enter 8 hours, or if field #1 is week, enter 40 hours.
(3) OVERTIME FACTOR
Enter the factor times which the standard pay rate is multiplied to determine overtime pay, i.e. enter 1.5 if rate is time and one half, or enter 2.0 if rate is double time.
SPS-2000 Program Manual v1.30 P Mode Programming
127
(4) ENFORCE OUT FOR BREAK OR OUT ENTRY
When clocking out there is a choice for [OUT FOR BREAK] or [OUT]. If Yes, you must enter the appropriate number for either choice, rather than just pressing OK to choose the default.
(5) TIP REPORTING % OF SALES
If Yes, the percentage entered here is calculated and reported on the Employee report.
(6) EMPLOYEE TIME-IN/OUT
Select EMPLOYEE # or CLOCK-IN CODE or FINGERPRINT.
(7) CLOCK IN/OUT EMP. WHEN Z TIME KEEPING REPORT
If Yes, all employees clocked in at the time of the Z Time Keeping report will be clocked out for the report and clocked back in after the report.
E.J. (Electronic Journal) & Detail Printing Option Definitions
(1) ACTIVATE ELECTRONIC JOURNAL
Select Yes to activate the electronic journal.
(2) DISPLAY E.J. BUFFER FULL WARNING
Select Yes to display a warning message when the electronic journal is full.
(3) E.J. OVERRIDE WHEN BUFFER FULL?
Select Yes to allow operations to continue when the electronic journal is full. Only the most current transactions will be maintained as memory allows.
(4) SEND TO ELECTRONIC JOURNAL:
CASH TRANSACTIONS
CHECK TRANSACTIONS
MISC TENDER TRANSACTIONS
TRANSACTIONS WITH %
RECD ACCT & PAID OUT
RETURN TRANSACTIONS
TRANSACTIONS WITH ERR CORR&VOID
NO SALES
CANCEL TRANSACTIONS
ONLY TRANSACTIONS WITH NEGATIVE ITEMS**
REPORTS
PROGRAM SCANS
CHECK TRACKING
CLERK INTERRUPT
ALPHA TEXT (v3.00a or later)
For each type of function or transaction listed, select YES or NO to determine it will be recorded in the electronic journal.
**Regardless of other settings, will send only transactions with negative items, % entries, tenders, etc. to the journal. (Reworded to say “only” at v3.00a or later.)
128
P Mode Programming
SPS-2000 Program Manual v1.30
(5) SEND TO DETAIL:
ONLY TRANSACTIONS WITH NEGATIVE ITEMS**
REPORTS
ONLY TRANSACTIONS WITHOUT NEGATIVE ITEMS**
PREAMBLE/POSTAMBLE (added V2.00c)
For each type of function or transaction listed, select Yes or No to determine it will be sent to the appropriate detail/journal printer. **Regardless of other settings, will send only transactions with negative items, % entries (any entry into a % function key, including coupons, surcharges, etc.) tenders, etc. to the detail.
** If both transactions with and without negative items are set to Yes, nothing will be sent to detail.
(Reworded to say “only” at v3.00a or later.)
(6) SEND TO ELECTRONIC JOURNAL:PLU CODE (requires v3.00w or later)
SPS-2000 Program Manual v1.30 P Mode Programming
129
Employee
The employee file contains information for register operators as well as employees who use the register only to clock in or out (employee time keeping.) Specific functions that are allowed or disallowed for each employee are determined by assigning the employee to an authority level. (See "Authority Level" on page
133.)
Two 10-digit code numbers may be assigned for each employee. A clock-in code is used to clock in or out and a separate sign on code used to operate the register. The social security number is for reference only and appears only on reports.
The total number of employees (up to 999) is set in memory allocation. See "Memory Allocation" in "S-
Mode Programming".
1. Select EMPLOYEE from the P-Mode menu, and then select EMPLOYEE to display the
EMPLOYEE selection screen. The program screen for the first employee in the file displays with the first of two pages of options in view.
2. Select an employee to program or edit by employee number (touch the current number and enter a new one) or by touching the NEXT RECORD or PREV. RECORD keys until the appropriate employee is in view.
130
P Mode Programming
SPS-2000 Program Manual v1.30
Employee Field Definitions
SOCIAL SEC #
Enter 9-digit identifying number.
CLOCK IN CODE
Enter a number (up to 10 digits in length) that will be used by this employee to clock in and/or out.
OPERATING CODE
Enter the secret code number (up to 10 digits in length) that can be used to sign in/out. Note that system option # 21 "EMPLOYEE SIGN-ON" must be set to "SECRET CODE" to use this number. See "General
Function Option" on page 109.
LINK TO AUTHORITY LEVEL
Operations and programs that can be accessed by this employee are determined by selecting an authority level here. See "Authority Level" on page 133 to define specific operations for each of 9 levels.
JOB CODE#/PAY RATE#
An employee might have more than one job, possibly with a different pay rate for each job. For example, in a restaurant, an employee might work as a server one day, and on a different day or shift, work as a cashier. Here you can list up to six different job codes and six different pay rates for each employee.
By assigning separate job codes and pay rates for each employee, the built in time clock can track and report hours and wage costs appropriately.
See "Time Clock Procedures" in the SPS-2000 Operation Manual for instructions on clocking on/off for different jobs. Note that the job code you assign for JOB1 is the default job code for clocking in/out.
OPEN DRAWER# DIRECT (0-2) VIA (3-9)
Select the drawer for this employee: No Drawer, Drawer Port 1, Drawer Port 2, or drawer connected to printers on serial ports 1-4. If No Drawer is assigned, the employee can only perform check track postings (not payments).
TRAINING MODE?
If Yes, this employee will be in training, regardless of the training mode status of the entire register.
DEFAULT PRICE LEVEL
Select the default price level for the employee. To use the level selected here, you must also set P-
Mode/System Options/Level Modifier option #7 to Yes.
DEFAULT SCREEN LEVEL (0-200)
Select the default screen level (Key Link) for the employee. To use the screen level selected here, you must also set P-Mode/System Options/Level Modifier option #11 to Yes.
MANAGER
If Yes, this employee will be allowed to perform manager functions without entering a manager password.
SPS-2000 Program Manual v1.30 P Mode Programming
131
EDIT JOB CODES
Note: An employee with the appropriate authority level must be signed on to perform job code programming.
Job codes are used to break down the hours worked for all employees into different categories (See
"Labor Groups" report in the Operation Manual.) A breakdown of hours by job is also reported for each employee (See "Time Keeping" reports in the Operation Manual.)
The job codes to be used by all employees are set up here. There are 20 possible job codes. Each job code you wish to activate must be given a descriptor here.
EDIT PAY RATES
Note: An employee with the appropriate authority level must be signed on to perform pay rate programming.
All employees can use the pay rates set here. There are up to 50 pay rates.
DALLAS KEY LINK
This option is not currently available.
ELROL FINGERPRINT
You must use the DIGENT IZZEX FD 1000 Fingerprint identification device available only from CRS.
You must set P-Mode menu SYSTEM OPTIONS, GENERAL FUNCTON OPTION #20,
EMPLOYEE SIGN-ON, to FINGERPRINT.
To record the employee fingerprint touch ENROL. The Fingerprints window displays. Touch the employee’s finger to scanner and touch ENROL again. The fingerprint is scanned and displayed. When complete touch CLOSE.
132
P Mode Programming
SPS-2000 Program Manual v1.30
Authority Level
Each employee must be assigned to one of nine authority levels. See "Employee" on page 130 to assign an employee to an authority level. The selections made here for each authority level determine the operations that are allowed for each employee.
For example, in a restaurant an authority level with the descriptor kitchen help could be set to allow only clocking in/out, or an authority level with the descriptor owner could be set up to allow all functions. Other authority levels could be defined for servers, cashiers and managers that allow only the appropriate functions.
Authority Level Options
(1) CLOCK-IN/OUT ENTRY ONLY
(2) MUST CLOCK-IN BEFORE SALES
(3) CAN CLOCK-OUT WITH OPEN CHKS
(4) GUEST CHECK ENTRIES ONLY
(5) PAYMENT OF OWN GUEST CHECK
(6) PAYMENT OF ANY GUEST CHECK
(7) TRANSFER OF GUEST CHECKS
(8) VOIDING OF SERVICED ITEMS
(9) ALLOW CANCEL AFTER RECALL
(10) CLOCK IN/OUT USING MCR
(11) SIGN IN/OUT USING MCR
(12) ALLOW EDIT ANY CHECKS
(13) ALLOW DESTINATION CHANGE
If Yes is set here, the operator has the option of selecting a destination (i.e. eat-in, take out, drive thru) other than the default.
(14) CAN COMBINE OWN SOFT CHKS
(15) CAN COMBINE ANY SOFT CHKS
(16) TABLE # TRANSFER IN R-MODE
(17) CAN PLU PRC/HALO OVERRIDE
(18) ALLOW SET DATE AND TIME
(19) ALLOW TIME CLOCK EDIT
(20) ALLOW CASH DECLARATION
(21) ALLOW PRICE LEVEL CHANGE
(22) ALLOW EMPLOYEE FILE EDIT
(23) ALLOW PRINT & RESET OF E.J
(24) ALLOW JOB CODE EDIT
(25) ALLOW PAY RATE EDIT
(26) CAN INVENTORY EDIT X MODE
(27) CAN INVENTORY EDIT PGM MODE
(28) ALLOW AUTHORITY LEVEL EDIT
(29) COMP SEAT# FOR EACH ENTRY
If seat # is implemented, and is not compulsory here, each item will default to seat "01".
SPS-2000 Program Manual v1.30 P Mode Programming
133
(30) ALLOW PLU QUICK REGISTER? (added V2.00c)
(31) ALLOW NO SALE
(32) PAID BREAKS
(33) MANAGER REQ. FOR CLOCK IN
(34) COMPULSORY TIP ENTRY
If Yes, the employee is prompted to declare tips when clocking out.
(35) JOB CODE CHANGE
If No, the employee can clock on using only the default job code; if Yes, the employee can select of the job code displayed at clock in.
(36) ALLOW PLU PRC CHANGE ONLY
If Yes, the employee can access the PLU programming screen, but can edit only the PRICE/HALO and
PRICE LEVEL fields.
(37) DISALLOW STOCK ADD IN P
(38) DISALLOW STOCK OVER IN P
(39) DISPLLOW STOCK SUB IN P
(40) ALLOW ACCESSING X/Z, S MODE WITHOUT PASSWORD
(41) ALLOW EFT BATCH OPERATION
If set to NO, Open Batch, Close Current Batch, and Close Batch with Debit functions will not be allowed from the EFT FUNC. function key.
(42) STRONG PASSWORD
If Yes, requires sign –in code and MCR sign on. Recommended for PABP (payment application best practices.
Groups By Employee
If you choose to use groups by employee (see "Memory Allocation" on page 47) you can select which of the
99 available groups are reported for each employee. For example, you may wish to report only food related groups for servers and beverage related groups for bartenders.
Employee Card
The standard MCR can be used to sign on/off or clock in/out employees. Options set here must match the format of the cards.
Employee Card Read Format Program Notes
READ
Set to the Track (1 or 2) that you wish to read.
CARD ID
If ID numbers are to be used, enter the ID number (up to 10 digits) from the magnetic cards that will be accepted. If ID numbers are not to be used, ignore this field.
CHECK CARD ID?
Enter Yes to use card ID numbers, or No if you do not wish to use card ID numbers.
COLUMN OF CARD ID
134
P Mode Programming
SPS-2000 Program Manual v1.30
Enter the number of the column that the Card ID starts.
CARD ID DIGITS
Enter the number of digits to be read for the Card ID.
COLUMN OF NUMBER
Enter the number of the column that the Card number starts.
CARD NUMBER DIGITS
Enter the number of digits to be read for the Card number.
SPS-2000 Program Manual v1.30 P Mode Programming
135
Reports
Use this program to create a custom report, modify the financial or employee report, or to define reports to be linked in up to four string reports.
Custom Report
One custom report can be created, with up to 50 totals and counters. The report is built by selecting totals that also appear on either the financial or sales by time period reports. When the custom report is created, totals and counters separate from the original report are also created (in other words, you can clear the custom reports independently without affecting totals in any other report.)
Another feature of the custom report is the ability to add or subtract selected totals to create a new subtotal of selected information.
1. From the PGM mode PROGRAMMING MENU touch REPORT to view the REPORTS selection window.
2. Touch CUSTOM REPORT to view the CUSTOM REPORT PROGRAMMING screen.
Custom Report Program Notes
RPT#
Touch RPT # to select the report (financial or sales by time) where the total you wish to place on the custom report originates.
TTL#
Touch TTL# to select the specific total you wish to select from the report.
PAGE UP/PAGE DOWN
Touch PAGE UP or PAGE DOWN to access up to 50 different totals on the custom report.
136
P Mode Programming
SPS-2000 Program Manual v1.30
RED?
+/-
Touch NO or YES in the RED column to select red/black print (provided the printer is capable of 2-color print).
Touch the button in the +/- column to select NONADD, +(ADD), or –(SUB) status for the selected total.
Depending upon your selection the total will not affect, add to, or subtract from the total at the end of the custom report. When the subtotal TTL# code (i.e.'999') is entered on a later line, previous totals with a + or - designation are added and printed.
DESCRIPTOR
The default descriptor automatically displays when the TTL# is entered. If you wish, enter a new descriptor by replacing default descriptor. Touch the Descriptor key, type new information into the field, and then touch OK.
NOTES: Use the total #998 to create a dashed separator line on the report; use the total #999 to create a subtotal line. The subtotal line will calculate the totals designated "+" or "-" that appear sequentially after the previous subtotal line. Enter a custom descriptor for the subtotal line.
Financial Report/Employee Report
The Financial Report and the Employee Report can be modified so that specific totals are deleted from the report or printed in red (provided the printer is capable of 2-color print).
1. From the PGM mode PROGRAMMING MENU touch REPORT to view the REPORTS selection window.
2. Touch FINANCIAL REPORT or EMPLOYEE REPORT to modify the report.
3. For each total, you can select YES or NO in the PRINT and RED columns. Use the PAGE UP and/or PAGE DOWN keys to view all of the totals.
4. Touch CLOSE to exit the program.
String Report
Up to four string reports can be created that automatically generate a sequence of up to 24 different reports.
Typically, string reports are used to automate end-of-day or end-of-period reporting requirements. Reports selected in the string sequence can be X (read) or Z (reset) reports and can be from report level 1-5.
1. From the PGM mode PROGRAMMING MENU touch REPORT to view the REPORTS selection window.
2. Touch STRING REPORT to view the STRING REPORT #1 PROGRAMMING screen.
3. If you are programming a string report other than string report #1, touch STRING REPORT # and select another report number (2-4).
4. You can program a descriptor for the string report by touching DESCRIPTOR.
5. Select X or Z, the REP LVL (1-5) and the RPT# for each report you wish to include in the report sequence.
6. Touch CLOSE to exit the program.
SPS-2000 Program Manual v1.30 P Mode Programming
137
Time
Time period definitions and time activated functions (Price Levels, Screen Level, Macros, String Reports,
Shifts, and KP Time Periods) are defined with this program.
Time Period
The Time report collects sales information depending upon the time of day. The number of time periods (24,
48, or 96) is selected in memory allocation. By default, time periods are hourly if 24 periods are selected, if
48 periods are selected, sales are accumulated in ½ hour periods, and if 96 periods are selected, sales are accumulated in 15 minute periods.
If hourly, ½ hourly or 15 minute report periods are satisfactory for your application, no action is necessary with this program. However, if you wish customize report periods (i.e. define five minute periods during rush periods or inactivate periods during closed times) you can individually define periods with this program.
All time units are based upon a 24-hour clock (military time).
1. From the PGM mode PROGRAMMING MENU touch TIME to view the TIME selection window.
2. Touch TIME PERIOD to view the TIME PERIOD PROGRAMMING screen.
3. For each period, you can adjust reporting times by touching the time and entering a new time. The number of periods available for programming will depend on your memory allocation selection.
4. Touch YES or NO to add or remove the period from the report
5. Touch CLOSE to exit the program.
Time Activated Functions
Time activated options include:
Price levels and Screen Levels (the default screen key link) can be automatically activated at specific times.
Macros and String reports can be generated automatically and repeated at specific times.
Shift time programming determines the times of day financial totals are accumulated for the Shift
Report.
Kitchen Printer/Video routing can be switched at specific times to accommodate slow/busy time requirements.
To set these options:
1. From the PGM mode PROGRAMMING MENU touch TIME to view the TIME selection window.
2. Touch TIME ACTIVATED FUNCTIONS to make a selection from the TIME ACTIVATED
FUNCTONS MENU.
3. Refer to the attached chart to determine the programmability for each time-activated function.
4. Touch CLOSE to exit the program.
138
P Mode Programming
SPS-2000 Program Manual v1.30
Time Activated Function Activate Time or
Start/End Times
Day of Week Repeat Time
Macros
String Report
Yes Yes Yes
Yes Yes Yes
Shifts Yes
Time Period Yes
Sending Time Activated String Reports to an FTP Site
The Time Activated String Report Function provides an option to send the string report to an FTP site. If this option is selected, you must first make the appropriate network settings and identify the FTP server address.
These settings are found in a separate document titled "SPS-2000/SPS 5X0 FTP Reports” that is posted under
Support Documents on the SPS-2000 and SPS-5X0 Dealer Support Pages. Go to this document for complete
FTP setup instructions. To select this option:
1. Go to PGM/TIME/TIME ACTIVATE FUNCTIONS/STRING REPORT. The appropriate Time
Activate String Report screen displays.
2. Select the SEND TO FTP option.
FILE NOTE: The string report is sent as a text file, for example: “0_REG1_STRREP120110309153601.txt” where:
0 = Store name
REG1 = Register Number
STRREP1 = String report #1
2011 = Year
03 = Month
09 = Day
153601 = Time
SPS-2000 Program Manual v1.30 P Mode Programming
139
Product & Ingredient
NOTE: Be careful not to confuse the separate and distinct inventory features of the SPS-2000:
A menu-explosion type inventory system is set up when PLUs are linked to a recipe#. Recipes and
Ingredients are programmed with this program.
Product Mix Groups can be used to implement a simplified ingredient system for tracking only essential ingredients associated with items (i.e. cups for beverages or number of pieces for chicken menus.) Product mix groups also report usage by time period and optional Product Projections reporting is also available. The Product Projection report provides a history of each item's sales by day of week. Product mix items and product mix group time periods are also programmed set with this program.
If used, The PLU Stock counters decrements for each activity in the PLU. PLU stock is set in the
PLU program, see “PLU Stock” on page 87.
Edit Ingredient
Before recipes can be created, ingredients must be entered.
1. From the PGM mode PROGRAMMING MENU touch PRODUCT & INGREDIENT to view the
PRODUCT & INGREDIENT selection window.
2. Touch EDIT INGREDIENT to access the INGREDIENT PROGRAMMING screen. .
5. Refer to the notes that follow.
3. Touch CLOSE to exit the program.
Ingredient Program Notes
ING#
This field is the three-digit inventory number. The value begins at 001 and goes up to the maximum number that is assigned in memory allocation.
DESCRIPTOR
A 12-digit descriptor is set for the inventory item. (An inventory item is an “ingredient” of a PLU.)
COST
The cost of the item is the cost of the ingredient. The cost can be entered accurate to three places after the decimal.
140
P Mode Programming
SPS-2000 Program Manual v1.30
Recipe Table
Here you assign ingredients to a recipe. If a PLU is linked to a recipe, PLU activity will cause the inventory of ingredients used in the recipe to decrement. Each recipe can use up to 20 ingredients.
1. From the PGM mode PROGRAMMING MENU touch PRODUCT & INGREDIENT to view the
PRODUCT & INGREDIENT selection window.
2. Touch RECIPE TABLE to access the RECIPE PROGRAMMING screen. .
3. Refer to the notes that follow.
4. Touch CLOSE to exit the program.
Recipe Table Program Notes
ING/RECIPE
Choose whether this line corresponds to an INGredient or a RECIPE. (A recipe may be composed of recipes. For example, a special sauce (a recipe) may be an ingredient of a sandwich recipe.)
#
Enter the 3-digit number of the recipe or ingredient.
DESCRIPTOR
Display only. When a recipe or ingredient number is entered, the corresponding descriptor displays.
QTY
Enter the amount of inventory items used in the recipe, i.e. 1 patty for a regular hamburger, or 2 patties for double hamburger.
Product Mix Items
Product Mix items are can be inventoried as they are purchased. For example, a box of burger patties.
Product Mix Item Program Notes
DESCRIPTOR
Each product mix group item can have a 12 character alpha descriptor.
PCS\UNIT
Enter the number of pieces in the unit. For the example shown, 120 burgers to the case- Enter 120; 30 cups to the sleeve- Enter 30.
UNIT@
Enter a 4 Character descriptor for the unit, using the Alpha-keyboard overlay. This descriptor is for report purposes.
SPS-2000 Program Manual v1.30 P Mode Programming
141
Product Mix Group Time Periods
Memory allocation determines whether there are 24, 48, or 96 product mix group time periods. (Time periods used for the Product Mix and Projections reports are defined separately from the time periods used for Time
Period sales reporting.) Product mix group time periods will default to hourly periods if 24 periods are selected in memory allocation; 30-minute periods if 48 periods are selected; 15-minute periods if 96 periods are selected.
Periods can be set to custom lengths using this program. If fewer periods are needed than are available, unneeded periods can be inactivated so that they will not appear on reports. To inactivate a period replace the
"A" (active) for the period with an "I" (inactive).
All time units are based upon a 24-hour clock (military time).
142
P Mode Programming
SPS-2000 Program Manual v1.30
Taxes
The SPS-2000 provides calculation for up to six taxes. Tax calculation can be made by ADD ON percentage, by TAX TABLE, or by VAT (value-added tax).
Provisions have been made for the Canadian Goods and Services tax (GST). If GST is to be taxable, you have the option of taxing the GST by other applicable rates (tax on tax). Use TAX 6 for GST applications.
1. From the PGM mode PROGRAMMING MENU touch TAXES to view the TAX PROGRAMMING
Screen.
2. Touch the TYPE button to select ADD ON, TAX TABLE or VAT.
3. Refer to the notes that follow to program each type of tax.
4. Touch CLOSE to exit the program.
Add On Taxes Program Notes
RATE
Enter the tax rate. If fractional, press the decimal and up to three digits.
THRESHOLD
Enter the highest non-taxable amount.
Tax Table Programming Notes
MAXIMUM NON-TAXABLE AMOUNT
Enter the highest amount where no tax is charged. For this example the entry is 0.10.
FIRST TAX AMOUNT CHARGED
Enter the first tax amount that is charged. For this example the entry is 0.01.
SPS-2000 Program Manual v1.30 P Mode Programming
143
# OF NON-REPEAT BREAKS
Enter the number of Non-repeat breaks. For this example the entry is 5.
# OF REPEAT BREAKS
Enter the number of repeat breaks. For this example the entry is 3.
BREAK POINT (1-100)
Enter the high amount in the range. For example, if the break point is .22 - .38, enter .38 for the break point.
Tax Table Programming Example - Illinois 6% Tax Table
1. Examine the printed tax table for the tax you are programming.
2. Examine the pattern of break point differences to determine when the break points begin to repeat. Mark the beginning break points that do not fit a pattern as “non-repeat breaks.” Mark the break points that are repeating in a pattern as “repeat breaks.” Count the number of repeat and non-repeat breaks.
Tax Charged Sale Amount Range Break point s
$0.00
$0.01
$0.02
$0.03
$0.04
$0.05
$0.06
$0.07
$0.08
$0.09
$0.10
$0.11
$0.12
$0.13
$0.14
$0.00 - $0.10
$0.11 - $0.21
$0.22 - $0.38
$0.39 - $0.56
$0.57 - $0.73
$0.74 - $0.91
$0.92 - $1.08
$1.09 - $1.24
$1.25 - $1.41
$1.42 - $1.58
$1.59 - $1.74
$1.75 - $1.91
$1.92 - $2.08
$2.09 - $2.24
$2.25 - $2.41
Non-Repeat
Repeat
144
P Mode Programming
SPS-2000 Program Manual v1.30
Messages
Various descriptors and messages are set with this program:
Message
Logo Message
Error Messages
System Descriptors
Report Descriptors
Check Endorsement
Message
Guest Check Logo Message
Validation Message
DataTran Message
Pole Display Message
Type of Message and Application
6-line x 40 character Preamble & Postamble. Appears on receipts
30-characters per message. Displays on message line of screen. Default messages are listed below.
The length of each descriptor varies. For example day of week fields are
3 characters, while other printed messages are 5 characters or more.
Default System Descriptors are listed below.
16-character descriptors for Financial and Employee report totals.
10-line x 40 characters. Prints when check is endorsed on an optional slip printer.
5-line x 40 character Preamble & Postamble. Prints at top and bottom of hard or soft checks
3-line x 40 character. Prints when forms are validated on an optional slip printer.
4-line x 32 character. Prints on electronic payment voucher/receipt.
A 25-character message can scroll left, right, or bounce left to right on an optional pole display.
Default Error Messages
NO. DESCRIPTION
7 BUSY
9 CASH DECALATION REQUIRED
11 CHECK# ASSIGNED AUTO
12 CHECK# REQUIRED !
13 CONDIMENT REQUIRED !
15 TABLE NUMBER IN USE
17 ENTER EMPLOYEE CODE
18 ENTER EMPLOYEE #
19 ENTER GUEST COUNT
NO. DESCRIPTION
23 ERROR
25 GALLON AMOUNT REQUIRED
27 ILLEGAL KEY SEQUENCE
29 INACTIVE!
31 KITCHEN PRINTER FAILURE
33 MANAGER OVERRIDE REQUIRE
35 NEGATIVE
39 NO MANUAL ENTRY
42 NON ADD# REQUIRED
SPS-2000 Program Manual v1.30 P Mode Programming
145
NO. DESCRIPTION
48
54
59
OPEN DRAWER
SCALE REQUIRED !
TRAY SUBTOTAL REQUIRED!
63 SIGN OFF REQUIRED
65 PRICE LEVEL MISMATCH
66 OVERRIDE NOT ALLOWED
69 WRONG FILE NO.
71 UNDER TEND NOT ALLOWED
72 OVER TEND NOT ALLOWED
73 CHECK TRACKING ERROR
74 USING
75 PLU NOT ALLOWED
76 CONDIMENT PLU NOT ALLOWED
77 NON-CONDIMENT PLU NOT ALLOWED
78 FUNCTION KEY NOT ALLOWED
79 THIS KEY IS NOT ALLOWED
80 NO FUNCTION KEY
81 NO PROGRAMMABLE KEY
83 INVALID AUTHORITY LEVEL
84 TIME IN REQUIRED
85 SIGN ON REQUIRED
86 MEMORY ALLOCATION NOT
ALLOCATED
87 THIS EMP. RPT MUST BE CLEARED
90 ERROR SYSTEM OPTION
92 ERROR TABLE NO.
146
P Mode Programming
NO. DESCRIPTION
96 PROMO NOT ALLOWED
97 WASTE NOT ALLOWED
98 NO FOOD STAMP AMOUNT
99 DECIMAL ENTRY NOT ALLOWED
100 SPLIT PRICING NOT ALLOWED
101 VOID MODE IS DEACTIVATED
102 JOB CODE REQUIRED
103 JOB CODE CHANGE NOT ALLOWED
104 PUSH BUTTON ENTRY REQUIRED
105 EMPLOYEE CODE NOT LINKED
106 TENDERING IS NOT ALLOWED
107 OVER REGULAR HOURS PER WEEK.
108 MUST <= LINE# PER TRANSACTION
109 MUST >= LINE# PER SOFT CHECK
110 NO STOCK PLU
112 LINKED STATUS REQUIRED
113 RETURN TO X-MODE
114 ERROR – SLIP PAPER
115 LOCAL PRINTER REQUIRED
117 SET TIME&DATE IS DECATIVATED
118 EMPLOYEE SHOULD BE DIFFERENT
119 TRANSFER NOT ALLOWED
120 REQ GALLONAGE AMOUNT
121 AVAILABLE ONLY IN CHECK
122 SPLIT THIS ITEM NOT POSSIBLE
123 FUNCTION KEY NOT INCLUDED
124 ERROR POST TENDER
125 NO TRACKING DATA IN THIS REG
126 NO TIME KEEP DATA IN THIS REG
127 MULTIPLICATION LIMIT EXCEEDED
128 TAB OF FIELD 2 IS TOO BIG
129 NON PLU CODE RANGE OVER
130 TARE ENTRY NOT ALLOWED
131 MISC TEND REQUIRED
132 SAME CHECK TRACK REQUIRED
133 NOT SCALEABLE PLU
134 EJ BUFFER FULL
135 MUST BE START<=END IN RANGE
137 FINAL END SHOULD BE 9 OR 99
140 PRINT KEY REQUIRED
141 SURCHARGE NOT ALLOWED
142 DECIMAL ENTRY REQUIRED
143
144
SYSTEM REG# REQUIRED
TRAINING EMP FILE# RQUIRED
145 TIME IN/OUT REG# REQUIRED
SPS-2000 Program Manual v1.30
NO. DESCRIPTION
146 CHECK TRACKING REG# REQUIRED
147
148
ELECTRONIC JOURNAL INACTIVE
CHEQUE ENDORSEMENT REQUIRED
149 EFT TERMINAL TRANS KEY ERROR
153
154
155
156
157
158
159
160
161
162
NO RELOCATABLE KEY
CLERK KEY ERROR
ENFORCE ACTUAL INVENTORY
AUTHORITY LEVEL NOT LINKED
WEIGHT IS ZERO
STOCK IS NOT ZERO
CLEAR CAN NOT BE REMOVED
ENTER CAN NOT BE REMOVED
YES/NO CAN NOT BE REMOVED
THIS NUMERIC CAN NOT BE REMOVED
164
166
167
168
169
170
171
172
SOFT CHECK ONLY
MULTIPLE DISCOUNT NOT ALLOWED
NEW CHECK OPENED
NO MORE SPLIT TENDER ALLOWED,
CHECK POLE DISPLAY
MUST MAX.NONTAXABLE <=BRK PNT1
MUST BRK PNT n <= BRK PNT N+1
NOT ALLOWED WITH OPEN ORDERS
174 INCORRECT TARE WEIGHT
175
176
VOID PROMO FIRST
MULTIPLE RECEIPTS NOT ALLOWED
177 MIX & MATCH ERROR
178 CLERK INTERRUPT ERROR
NO. DESCRIPTION
179 CHECK OPENED NO DATA
180 NO CLERK BUFFER IN THIS REG
181 NOT ALLOWED WITH OPEN CLERKS
183 X/TIME NOT ALLOWED
184 OUT OF STOCK
186 Z STOCK NOT ALLOWED
187 Z1 TIME KEEPING NOT ALLOWED
188 PLU NOT INCLUDED
190 GIFT CARD DUPLICATED
191 DEVICE ALREADY OPENED
192 DEVICE OPEN ERROR
195 INVALID SD CARD
197 CHOOSE IRC REPORING
198 PLEASE CHECKSD CARD
199 FILE NOT FOUND
200 USING ALPHA AS CHECK#
202 UNDER MINIMUM STOCK
203 PLEASE CHECK USB
205 PRINT CHECK FIRST
206 SELECTIVE DISCOUNT ERROR
207 NO ITEM FOR SELECT. DISCOUNT
208 RESTORE DALLAS KEY
209 MODIFICATION NOT ALLOWED
210 VOID LAST DISCOUNT FIRST
SPS-2000 Program Manual v1.30 P Mode Programming
147
Default System Descriptors
NO DESCRIPTION
1 SUN
2 MON
3 TUE
4 WED
5 THU
6 FRI
7 SAT
8 MGR
9 TAXES
10 TOTAL
11 FSTAX
12 FSTTL
13 FSCNG
14 DATE
15 TIME
16 NO.
17 CASH
18 CHEQ
19 MISC
20 REG
21 PLU#
22 PBAL
23 SEAT#
24 ESC
25 TBL
26 GST
27 CSHR
28 FOR
50 RESERVED
51 RESERVED
52 RESERVED
53 ENTER NV NO.
55 IN -- OUT
TRANSACTION
59 TRANSACTION WITH %
60 RA/PO
61 RETURN/CANCEL
TRANS
62 ERR.CORR./VOID
65 TRANS. WITH NEGA.
ITEMS
66 REPORTS
30 *TRAINING*
31 TIME CLOCK – IN
32 TIME CLOCK – OUT
33 EMPLOYEE SIGN ON
34 EMPLOYEE SIGN OFF
35 DECLARE CASH TIPS
36 TODAY
37 TIME CLOCK – BRK
38 RESERVED
39 RESERVED
40 ADD CHECKS FOR
PAYMENT
41 *NOT CLOSED CHECKS*
42 ENTER NEW SEAT#
44 RESERVED
45 RESERVED
46 RESERVED
47 RESERVED
48 RESERVED
49 RESERVED
73 RESERVED
74 POWER FAIL COUNT:
75 RESERVED
76 RESERVED
77 RESERVED
78 RESERVED
79 RESERVED
80 RESERVED
81 RESERVED
82 RESERVED
83 RESERVED
84 RESERVED
85 RESERVED
86 RESERVED
87 RESERVED
88 RESERVED
89 RESERVED
90 RESERVED
91 RESERVED
92 RESERVED
93 RESERVED
94 RESERVED
95 RESERVED
96 RESERVED
97 RESERVED
139 OUT FOR BREAK
140 OUT
141 OPERATOR
142 NON-ADD#
146 PAYMENT
148 FSCRT
98 RESERVED
99 RESERVED
100 RESERVED
101 RESERVED
102 RESERVED
103 RESERVED
104 RESERVED
105 RESERVED
106 RESERVED
107 RESERVED
108 RESERVED
109 RESERVED
110 RESERVED
111 RESERVED
112 RESERVED
113 RESERVED
114 RESERVED
115 RESERVED
116 RESERVED
117 RESERVED
118 RESERVED
119 RESERVED
120 RESERVED
121 RESERVED
122 RESERVED
123 RESERVED
124 RESERVED
125 RESERVED
126 RESERVED
127 RESERVED
128 RESERVED
129 RESERVED
130 RESERVED
131 RESERVED
132 RESERVED
134 EMPLOYEE
135 NAME
148
P Mode Programming
SPS-2000 Program Manual v1.30
151 ITEMS
182 CHECK#
184 CLOSED
185 PRICE/HALO
186 DESCRIPTOR
194 CONV
216 NOTIFICATION
217 SERVED
218 SINGLE
SEATS
SEATS
SEAT
222 RESERVED
223 RESERVED
224 RESERVED
225 RESERVED
227 TITLE
197 ORDER#
198 REPRINT
199 GROUP0
202 ENTER AUTH CODE
203 ENTER REF CODE
205 ENTER ACCT NO
206 ENTER EXP DATE
230 ADDRESS
231 ADDRESS2
232 CITY
234 TELEPHONE
236 EMAIL
237 LAST
VISIT(MMDDYYYY)
239 CRITERIA
209 ENTER BATCH NO
210 ENTER RECORD NO
211 ENTER ORIG. TRAN
AMT
212 ENTER TIP AMT
180 SYSTEM
181 BALANCE
Message Definitions
AMOUNT REQUIRED
This operation requires an amount entry.
BAD VALUE
The number entered is incorrect for the task being performed.
BUFFER FULL
A buffer (i.e. or soft check, hard check, time clock, buffered receipt) has reached capacity. For hard checks, the operator must press the SERVICE key to print the items and clear the buffer. The operator must then pick up the previous balance again in order to continue with finalization. In a soft check environment, this message will appear when the check has reached capacity (maximum lines stored). The register will require the sale to be finalized with the option of printing a bill if required
SPS-2000 Program Manual v1.30 P Mode Programming
149
BUSY
Destination register is busy (pre poll memory is in use). Requires a clear command from the P.C. or register. Message also displays when master register is busy and a integrated payment operation is pending.
CASH DECLARATION REQUIRED
Cash declaration has been programmed as compulsory, and must first be performed before reports
CASH-IN-DRAWER LIMIT EXCEEDED
The programmed Cash-In-Drawer limit has been exceeded.
CHECK KEY POSITION
The key lock is in the wrong position.
CHECK# IS ASSIGNED AUTOMATICALLY
The operator has attempted to open a new guest check by assigning a check number. The register has been programmed to generate its own check numbers.
CHECK# REQUIRED!
This register has been programmed to force check number entry to begin a transaction. An existing guest check must be recalled, or a new one started.
CONDIMENT REQUIRED!
This PLU has been programmed to require a condiment entry.
CRC ERROR
An error has occurred in the block check sum while transferring data in IRC mode.
DUPLICATE!
This check already exists. May also apply to secret code programming.
EAT IN/TAKE OUT/DRIVE THRU
This operation is set for compulsory entry of one of the three destination keys.
ENTER EMPLOYEE CODE
The employee is required to sign on before performing a task.
ENTER GUEST COUNT
The operator must enter the number of guests when opening a guest check, or beginning a sale.
ENTER SEAT#
Seat # entry required before operation can continue.
ENTER TABLE#
Table number entry is required to open a guest check, or begin sale.
ENTRY REQUIRED
The function selected requires a numeric entry, i.e. a percentage for an open percent discount.
ERROR
General error message.
ERROR JAM
Receipt / journal printer jammed message.
150
P Mode Programming
SPS-2000 Program Manual v1.30
GALLON AMOUNT REQUIRED
This entry involves a gallonage PLU, and requires an amount entry.
HALO OVER!
The amount entered exceeds the programmed HALO i.e. the task exceeds the maximum amount allowed.
ILLEGAL KEY SEQUENCE
The operator has used an illegal key sequence.
IN USE!
This guest check or clerk number is already open elsewhere in the system. This is also applicable when the floating clerk system is activated and the operator is in use on another ECR.
INACTIVE!
The key pressed is inactive. This message also appears if VOID Mode has been disabled.
INPUT QTY
Quantity input is required for a condiment WLU
KITCHEN PRINTER FAILURE
The kitchen printer has failed to respond. Printing has been re-routed to the designated back-up printer.
MANAGER OVERRIDE REQUIRED
Manager code entry required to override a HALO amount, or other restriction.
MANAGER REQUIRED
This operation requires entry of the manager code.
MEMORY FULL
Memory is full.
NEGATIVE
This sale has gone negative. Negative sales are programmed as not allowed.
NO CHECK #
This message appears when the system cannot find this guest check number.
NO DATA
PLU cannot be found (does not appear in Register Mode). Usually associated with stock entry on an IRC system when the PLU exists in one ECR but not another. On the ECR where the PLU does not exist the message not found will appear.
NO DRAWER!
The employee currently signed on is not assigned to a drawer, and is not allowed to perform cash sales, or the drawer is no longer attached and is required in order to continue.
NO MANUAL ENTRY
Manual entry is not allowed (scale function).
NO PAPER
Slip printer is out of paper, appears when printing to a loose-leaf printer.
SPS-2000 Program Manual v1.30 P Mode Programming
151
NO PLU!
The number entered is not a valid PLU. This message will also appear if a PLU number “built” using modifier keys recalls an invalid PLU number.
NONADD# REQUIRED
This operation requires the entry of a Non-Add number to fulfill the compulsory requirements.
NOT DISCOUNTABLE
The preceding entry is not discountable; product is not available for discounting.
NOT PROGRAMMED!
This key has not been programmed
NOT READY!
Remote printer is not ready for printing tasks.
NOT ZERO
Displayed when trying to delete a PLU that still has sales counts and stock amounts. The PLU must first be reset and cleared from all Z Mode reports.
OFF LINE!
IRC communications have gone off line.
OPEN DRAWER
The register has been programmed not to operate with the cash drawer open.
OVERRIDE NOT ALLOWED
Override is not allowed for this operation.
P/BAL REQUIRED!
This register has been programmed to require a previous balance entry.
PAPER END
The guest check printer has reached the end of the form, or the Receipt/Journal paper is at, or near, the end of its roll.
RANGE OVER
The number entered is out of range.
REMOVE PAPER
Validation is complete and the paper must now be removed.
SCALE FAIL!
The register is not able to find the scale.
SCALE REQUIRED!
This item requires a weight this may be entered either manually or automatically.
SEQUENCE ERROR!
The preceding key sequence is not allowed.
SINGLE ITEM!
This PLU has been programmed as a single item PLU and cannot be used within a sale.
152
P Mode Programming
SPS-2000 Program Manual v1.30
SUBTOTAL REQUIRED
The SUBTOTAL key must be depressed before continuing.
SYSTEM ERROR
Normal Operation error.
TARE# REQUIRED
This PLU/scale item requires a tare weight entry.
TRAY SUBTOTAL REQUIRED!
This prompt appears while in a TRAY SUBTOTAL transaction. The operator must first press the TRAY
SUBTOTAL key before pressing any tender keys.
VALIDATION REQUIRED!
This operation requires validation to complete the compulsory settings.
WASTE REQUIRED!
The operator is in the middle of a waste operation, and must depress the WASTE key in order to complete the operation.
WRONG EMPLOYEE
The employee attempting to open this guest check is not the original person who started the guest check.
Also appears when attempting to sign on a new employee without first signing the current employee off, if overlap employee is not programmed.
ZERO AMOUNT
The register has been programmed to not allow negative sales, and to consider a zero amount as a negative sale.
SPS-2000 Program Manual v1.30 P Mode Programming
153
Printer & KV Routing
The printing system of an SPS-2000 register or system of registers is completely flexible. Up to 40 printers can be defined and connected to any available serial port on any register within a system. Multiple printer functions can be assigned to the same printer, giving added flexibility.
1. Before programming here, you must first:
See "Define Port" in S Mode Programming to define the type of device (i.e. printer or kitchen video) that is connected to a serial port and to match the baud rate/parity/etc. between the serial port and the printer. This program also controls the feed lines before and after printing, the logo size, and cutting options.
See "Printer Driver Selections" if you are using a printer other than the printers with predefined drivers, or if you need to customize a driver for a printer.
2. Next, assign a port for each printer. Select SYSTEM PRINTER CONFIGURATON to assign the printer number (1-40), give it a 10 character descriptor (i.e. salad prep, receipt, or detail) and identify the port # and the register # to which it is attached. In addition, you can identify a back-up location for information designated to go to the printer. (For example, if the salad printer is not functioning, then information destined for that printer could be sent to a different printer.)
3. Finally, proceed with the parts of this program that pertain to your application:
If you are using a kitchen video, select Kitchen Video Routing to designate the port # and the register
# where the video controller is attached. You can also define a backup printer in case communication with the video controller is disrupted.
If you are using kitchen printers, select Kitchen Printer Routing to link kitchen printer groups with a printer. (The groups of items are defined by assigning PLU items to PLU Status groups where groups are identified.)
Because different registers might route kitchen printer items to different printers, each register can be programmed separately in this program. (See "Kitchen Printing/Video Option Definitions" (option
#11) on page 119 to allow separate routing by register.) All registers contain routing information for all of the registers in the system.
NOTE: You will need to download any changes made to all registers in the IRC system.
Because it is sometimes necessary to change kitchen printer routing depending upon the time of the day, (for example, separate hot and cold food kitchens may be active during lunch and a single kitchen active during dinner) you can make assignments for four different periods. The active routing period can be controlled automatically by time or set manually.
Priority printing is also controlled with this program. The order in which items are printed on the kitchen printer ticket is determined by the order in which kitchen printer groups are listed for each printer #. (Groups at the left are printed first; groups at the right are printed last.)
If you are using receipt printers, see select Receipt Printer Routing to set the receipt printer for each location.
If you are using detail printers, see Detail Printer Routing to designate the journal printer for each location.
154
P Mode Programming
SPS-2000 Program Manual v1.30
Promotion Table
Retailers often offer discounts when multiples of items are purchased. Through the Promotion Table, you can handle four different discount situations (mix & match percentage added at version 2.03j.)
1. Mix & Match
This discount situation takes place where the merchant offers a fixed amount discount when a specific quantity of similar items are purchased. For example, “save $5 on any three bottles of wine”. This discount is implemented by first linking the applicable PLUs to a specific promotion table. At the promotion table screen, set the discount price field with the discount amount and the fixed quantity field with the number of items that need to be purchased in order to qualify for the discount.
Mix & Match %
This discount situation is similar to mix & match, except a percentage discount is applied (rather than an amount discount) when the discount criteria is met.
2. Multi Buy
This discount situation takes place where the merchant offers a fixed amount discount when a specific combination of items is purchased. For example, purchase 2-hamburgers, 1-french fry and 1-medium soft drink to receive a $1 meal discount. To implement this discount, you must list each item and the qualifying quantity that must be purchased on the promotion table program screen. Enter the amount of the combination discount in the discount price field.
3. Fixed Price
The fixed price discount is similar to the mult-buy discount. In both situations specific items must be sold to qualify, except when using the fixed price option, the package price is programmed instead of the package discount. For example, purchase 3-roast beef sandwiches for $3. In this case, the roast beef sandwich will be listed on promotion table screen with a quantity of “3”. The discount price field will be set at $3, which is the actual cost of the package.
4. Selective Discount
(Note: Software version 2.01n or later is required to implement selective discounts.) Selective discount enables a “coupon search” feature. In other words, before a coupon is allowed, the product for with the coupon applies, must be register in the transaction. The selective discount promotion is applied by first programming a “%” function key, and then setting the options on the Promotion
Table programming screen. The “Mix&Match Table #” field on the PLU must be set to “00”. The discount is applied by first entering the promotion table number, then touching the “%” function key.
If the discountable item is not registered, a “NO ITEM FOR SELECT DISCOUNT” error will display and the discount will not be applied. Beginning at version 2.03j, the FIXED QTY field will determine how many times the discount is applied.
SPS-2000 Program Manual v1.30 P Mode Programming
155
File Management
Utilities available from the file management menu include:
COPY PLU
Copies the attributes of one PLU to another. If “Allow PLU copy by Range” is allowed (see “General Function Option Definitions” on page 109) you can copy the attributes of a PLU to a range of
PLUs.
COPY PLU STATUS GROUP
Copies the attributes of one PLU Status Group to a range of other
PLU Status Groups
COPY GROUPS BY EMPLOYEE
PROGRAM DOWNLOAD
Copies the “GROUPS BY EMPLOYEE” settings from one employee to another.
Allows downloading of all or selected programs to all or selected registers.
156
P Mode Programming
SPS-2000 Program Manual v1.30
P-Mode PGM Scan
This function allows you to print copies of the register’s P-Mode programming. The following printouts are available:
PLU BY RANGE PLU BY PLU STATUS GROUP
PLU BY SELECTED PRICE LEVEL
GROUP BY RANGE
SYSTEM OPTION
PLU STATUS GROUP BY RANGE
ALL FUNCTION KEYS
TAXES
EMPLOYEE BY RANGE
PAY RATE
PRINTER TABLES & KV ROUTING
TIME ACTIVATED FUNCTION
MIX & MATCH TABLE
STRING REPORT
PLU MINIMUM STOCK BY RANGE
TARE WEIGHTS
GROUPS BY EMPLOYEE BY RANGE
JOB CODE
AUTHORITY LEVEL
INGREDIENT INVENTORY
PRODUCT MIX GROUPS
CUSTOM REPORT
PLU STOCK BY RANGE
NON-PLU CODE
MACRO
DELIVERY INFO
Key Relocation
The program provides the same key relocation options also provided available S mode.
SPS-2000 Program Manual v1.30 P Mode Programming
157
Program Guides
Delivery System Program Guide
1. Set the number of delivery tables: S/Memory Allocation/Option #33.
2. Use tracking file #1 for delivery tracking: S/System Options/Option #21.
3. Set Tracking files as you would any in other tracking system:
Set the register number that holds check tracking data and the register that holds back-up data
(S/System Options/Options #10 & 11 -- for single register systems, just set the register number.)
Set Memory Allocation for number of lines per check and maximum number of checks
(S/Memory Allocation/Options # 11 & 12). Be certain that the number of tracking files available exceeds the number of delivery tables that might be open at one time.
4. Use the Key Relocation program to assign function keys as necessary: Delivery (function key code
#069); Park Delivery (function key code #070); Serv Delivery (function key code #071).
5. Use the Key Relocation program to assign Store Check 1, Recall Check 1, and List Check 1 function keys. Use the default options for the Recall Check 1 key, do not enable drive thru, set
“assigned by register” to No, and set the length of Check# in Digits” to 00.
Training Mode Program Guide
1. Designate an employee file to be used for training. Set the P Mode Employee Option for that employee to “Training Mode” = YES.
2. Refer to P Mode System Options/Training Mode Options select printing, drawer and other training related options.
Program Guides
159
SPS-2000 Program Manual v1.30
Table Management Program Guide
S Mode System Option #16 determines whether the table display is automatic or manual. Set “Use
Graphic Table Management” to YES for automatic table display; Set to NO for manual display.
When using graphic table management, the table number or name corresponds with the guest check number (not the table number.) Set options for the appropriate recall check key as follows:
Set “Table Entry Required” to NO
Set “Assigned by Register” to NO
Set other Recall Check key options a necessary
S Mode Memory allocation for maximum number of checks (option #12) must exceed the number of tables in use.
S Mode System Options #10 and #11 must be set to locate the check file in the register system.
Table Set Up
From the S Mode menu touch Table Management. A blank table layout displays.
Table Management Setup Functions
Location Keys move a table
Touch Move, then Touch the New Table Location
Edit a Table
Delete a Table
Delete All Tables
Change Table Shape
Set Screen
Background Color
Set Names for each Floor
Select one of five floors
Add a new table
Add a group of tables
160
Program Guides
SPS-2000 Program Manual v1.30
Adding a New Table
1. Touch New Table.
2. From the New Table dialog, touch the table# key and enter the number or name to be associated with the table. Select the tracking file (1-4) that is being used and touch OK. The new table displays in the center of the screen.
Note: If you add more than one new table at a time, each new table will be located on top of the previous table in the center of the screen. You must move each table as it is added.
SPS-2000 Program Manual v1.30 Program Guides
161
Adding a Group of Tables
1. Touch In Tabular Form.
2. Enter the number of table columns (1-5) in the Width field.
Enter the number of table rows (1-6) in the Height field.
Select the tracking file (1-4) that is being used and touch OK. The grid of new tables displays.
3. Move or change shapes of tables as necessary.
162
Program Guides
SPS-2000 Program Manual v1.30
Moving a Table
1. Touch the table you wish to move to select it.
2. Touch the location keys U (up), L (left), R (right), or D (down) to move the table to the appropriate location, or
Touch the Move key and then touch the location on the screen where you wish to locate the table.
Selecting a Table Shape
1. Touch a table to select it.
2. Touch Table Shape.
3. Touch the table shape you wish to apply.
Editing a Table
1. Touch a table to select it.
2. Touch Edit Table.
3. Enter a new table number/name or tracking file and touch OK.
Deleting a Table or Tables
1. Touch a table to select it.
2. Touch Del Table. The table is removed from the screen.
Or,
Touch Delete All to remove all tables from the screen.
SPS-2000 Program Manual v1.30 Program Guides
163
Adding Floors
1. Touch Floor Info.
2. Enter names for each floor as necessary.
3. Touch OK.
Open the Floor list box to select and display the appropriate floor.
164
Program Guides
SPS-2000 Program Manual v1.30
Alternative Table Shapes/Backgrounds
You can create customized table shapes, table colors, and table backgrounds using a graphic image program such as Microsoft Paint. Table images must be in the correct size and have the correct file name. Custom images are loaded into the SPS-2000 using an SD card and the Image Copy function from the Key Relocation program. Refer to the table below for image names and sizes.
Alternative table images, including round table sizes, are posted on the dealer support page of www.crsusa.com
. You can add images selectively, in other words, you can use some of the standard table images and substitute only where you need a different table shape. Avoid mixing images with different colors; colors represent the table status and you would not wish to have two different colors representing the same table status, i.e. open table.
Note that each table shape is represented with three images; one image for each of the three table situations:
Empty, Open and Printed. Typically each table will be represented in three different colors to define table availability.
Table Image Specifications
Empty Table name
Size
Table
Shape1
Table
Shape2
Table
Shape3
Table
Shape4
Table
Shape5
Table
Shape6
Table
Shape7
Tableshape1_1.gif
77 x 57 pixels
Tableshape2_1.gif
117 x 57 pixels
Tableshape3_1.gif
157 x 57 pixels
Tableshape4_1.gif
75 x 75 pixels
Tableshape5_1.gif
115 x 115 pixels
Tableshape6_1.gif
77 x 117 pixels
Tableshape7_1.gif
77 x 157 pixels
Existing Table name
Size
Tableshape1_2.gif
77 x 57 pixels
Tableshape2_2.gif
117 x 57 pixels
Tableshape3_2.gif
157 x 57 pixels
Tableshape4_2.gif
75 x 75 pixels
Tableshape5_2.gif
115 x 115 pixels
Tableshape6_2.gif
77 x 117 pixels
Tableshape7_2.gif
77 x 157 pixels
Printed Table name
Size
Tableshape1_3.gif
77 x 57 pixels
Tableshape2_3.gif
117 x 57 pixels
Tableshape3_3.gif
157 x 57 pixels
Tableshape4_3.gif
75 x 75 pixels
Tableshape5_3.gif
115 x 115 pixels
Tableshape6_3.gif
77 x 117 pixels
Tableshape7_3.gif
77 x 157 pixels
Backgrounds
Eight alternative table backgrounds are also available. Each background image is an 80 x 80 pixel image that is replicated as the screen background. The seven available background images must be named
Tableback_1.jpg, Tableback_2.jpg, etc., through Tableback_7.jpg.
SPS-2000 Program Manual v1.30 Program Guides
165
Alternative Table Images
The chart below depicts the alternative table images that are posted at www.crs-usa.com
. These images are available in the default colors (pink/orange/green) and in custom colors (bronze, orange, green).
Empty Table Existing Table Printed Table
Table
Shape1
Tableshape1_1.gif Tableshape1_2.gif Tableshape1_3.gif
Table
Shape2
Tableshape2_1.gif Tableshape2_2.gif Tableshape2_3.gif
Table
Shape3
Tableshape3_1.gif Tableshape3_2.gif Tableshape3_3.gif
Table
Shape4
Tableshape4_1.gif Tableshape4_2.gif Tableshape4_3.gif
Table
Shape5
Tableshape5_1.gif Tableshape5_2.gif Tableshape5_3.gif
Table
Shape6
Tableshape6_1.gif Tableshape6_2.gif Tableshape6_3.gif
Table
Shape7
Tableshape7_1.gif Tableshape7_2.gif Tableshape7_3.gif
166
Program Guides
SPS-2000 Program Manual v1.30
Guest Check Tracking Program Guide (Soft Check)
You must set the check tracking method to “Soft”. See S Mode Memory Allocation option #8.
You must set the maximum number of lines per check. See S Mode Memory
Allocation option #11.
You must set the maximum number of check for each tracking file. See S Mode
Memory Allocation option #12.
You must set the register number that holds the check tracking file and backup file.
See S Mode System options #10 and #11.
You must assign function keys as necessary
RECALL CHECK (1-4) – Use to open or recall checks
STORE CHECK (1-4) – Use to finalize postings
TABLE (1-4) – Use to assign a table number or recall a check
LIST CHECK (1-4) – Use to view open checks
TRANSFER CHECK (1-4) – Use to transfer checks
You must set the options for the Recall Check key. See P Mode Function Keys
#197-200. Options set here include:
Enforce Seat Number
Table Entry Required
Multiple Checks Allowed for each Table
Guest Count Entry Required
Compulsory for all Sales
(Check #) Assigned by Register
Opening Employee has Exclusive Access
Print Receipt after Store Check
Other related options
Set P Mode System Options/Tracking File Options
Starting Check Numbers
Options to reset check numbers on Z of Financial or Open Check Reports
Option to print Barcodes on checks
Option to use Alpha Check Numbers
SPS-2000 Program Manual v1.30 Program Guides
167
Employee Time Keeping With MCR – Program Guide
1. Set the CARD READER ENABLE option to YES. (GENERAL FUNCTION
OPTIONS)
2. Set EMPLOYEE TIME-IN/OUT option to CLOCK IN CODE. (TIME KEEPING
OPTIONS)
168
Program Guides
SPS-2000 Program Manual v1.30
3. Program the EMPLOYEE CARD READ FORMAT.
FIELD Notes
READ
CARD ID
CHECK CARD ID?
Set to the Track (1 or 2) that you wish to read.
If ID numbers are to be used, enter the ID number (up to 10 digits) from the magnetic cards that will be accepted. If ID numbers are not to be used, ignore this field.
Enter Y to use card ID numbers, or N if you do not wish to use card ID numbers.
Enter the number of the column that the Card ID starts. COLUMN OF CARD
ID
CARD ID DIGITS
COLUMN OF
NUMBER
CARD NUMBER
DIGITS
Enter the number of digits to be read for the Card ID.
Enter the number of the column that the Card number starts.
Enter the number of digits to be read for the Card number.
SPS-2000 Program Manual v1.30 Program Guides
169
4. Enter Employee CLOCK IN CODE. (EMPLOYEE PROGRAMMING)
5. ** You can swipe employee card at this screen.
6. Program JOB CODE and PAY RATE for the employee.
170
Program Guides
SPS-2000 Program Manual v1.30
7. Set CLOCK IN/OUT USING MCR option to YES. (AUTHORITY LEVEL
PROGRAMMING)
8. On REG screen, press CLK IN/OUT button to time in/out the clerk.
SPS-2000 Program Manual v1.30 Program Guides
171
9. Slide the clerk card.
10. Select job code and touch OK.
172
Program Guides
SPS-2000 Program Manual v1.30
Employee Sign On with MCR – Program Guide
1. Set the EMPLOYEE SIGN-ON option to OPERATING CODE. (GENERAL
FUNCTION OPTIONS)
2. Set the CARD READER ENABLE option to YES. (GENERAL FUNCTION
OPTIONS)
SPS-2000 Program Manual v1.30 Program Guides
173
3. Program the EMPLOYEE CARD READ FORMAT.
FIELD
READ
CARD ID
Notes
Set to the Track (1 or 2) that you wish to read.
If ID numbers are to be used, enter the ID number (up to 10 digits) from the magnetic cards that will be accepted. If ID numbers are not to be used, ignore this field.
CHECK CARD ID?
Enter Y to use card ID numbers, or N if you do not wish to use card
ID numbers.
COLUMN OF CARD ID
Enter the number of the column that the Card ID starts.
CARD ID DIGITS
Enter the number of digits to be read for the Card ID.
COLUMN OF NUMBER
Enter the number of the column that the Card number starts.
CARD NUMBER
DIGITS
Enter the number of digits to be read for the Card number.
174
Program Guides
SPS-2000 Program Manual v1.30
4. Enter Employee OPERATING CODE. (EMPLOYEE PROGRAMMING)
5. ** You can swipe employee card at this screen.
6. Set SIGN IN/OUT USING MCR option to YES. (AUTHORITY LEVEL
PROGRAMMING)
7. On REG screen, you can sign on/off using the card.
SPS-2000 Program Manual v1.30 Program Guides
175
Open Check by MCR – Program Guide
Note: This feature requires software version 2.00s or later.
1. Set the CARD READER ENABLE option to YES. (GENERAL FUNCTION
OPTIONS)
2. At the P Mode, SYSTEM OPTION/TRACKING FILE OPTION #18, select:
The tracking file that will be used: CHECK #1, #2, #3 or #4
The magnetic track that will be read: track 1 or track 2
Enter the number of the column that the Card number starts
Enter the number of digits to be read for the Card number.
176
Program Guides
SPS-2000 Program Manual v1.30
Determining MCR Settings
1. Read data from a sample card using the SPS-2000 Self Test program. (From the S
Mode menu, choose SELF TEST and then MSR. Slide the card through the card reader.)
Track 2 Data
Track 1 Data
2. The “Start” value is the number of the digit (counted from left to right) where the tracking number will begin; the “Digit” value determines how many digits will be read.
For example, for the value read for MSR #2 above:
12345
;2258027
If the Start value (count 5-digits from left to right) = 5 and the Digit value (the next 3-digits will be read) = 3 the tracking number read will be 802
SPS-2000 Program Manual v1.30 Program Guides
177
178
Program Guides
SPS-2000 Program Manual v1.30
Appendix
Report Function Key Report Code Structure
You can print out reports from the REG tab using the REPORT key. Reports are generated by first entering the report code, then touching the REPORT key, i.e.:
[Report Code] [REPORT]
The REPORT key code is #36 and is available on software versions 2.00j or later.
Report Code Structure
010100
1. Enter the 2-digit report number. See the “Report Table” below.
2. Enter “0” for X reports; enter “1” for Z reports
3. Enter the report level: “1” through “5”
4. Enter “0” for standalone reports: enter “1” for IRC reports, (or “2’ to view
IRC for all registers without entering the IRC range with v.2.02b or later).
5. Enter the option code, 1-4 digits. See the “Report Option Table” below. If no option is selected, enter “0”.
The report code example above “010100” generates an X1 Standalone Financial Report.
Report # Table
NO. REPORT NAME
01 Financial
02
03
04
05
Sales by Time Period
All PLU’s
Not use this by REPORT key function.
PLU’s by Group
X/Z & REPORT LEVEL IRC
X1 & Z1 also X5 to Z5 INDIVIDUAL & IRC
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
INDIVIDUAL & IRC
INDIVIDUAL & IRC
X1 & Z1 also X5 to Z5 INDIVIDUAL & IRC
SPS-2000 Program Manual v1.30 Appendix
179
PLU’s by Group for Selected Group
Top 20 PLU’s
PLU Zero Sales
PLU Zero Sales by Group
PLU Sales by Price Level
Mix and Match report
Not Found
Employees
Individual Employees
Employee Currently Signed on
Groups by Employee
Groups
From/To Groups
Selective Groups
Drawer Totals
Drawer 1/2/3
Labour Groups
Sales & Labour %
Daily Sales
Groups By Time Period
Analysis 1By Time Period
Analysis 2 By Time Period
Analysis 3 By Time Period
Track 1 By Time Period
Track 2 By Time Period
Track 3 By Time Period
Track 4 By Time Period
Checks for Track 1
Checks for Track 2
Checks for Track 3
Checks for Track 4
Checks for Selected Employee
Checks for Current Employee
Checks for Track 1,2,3,4
Product Mix
Product Projections
37
38
39
40
41
34
35
36
30
31
32
33
26
27
28
29
23
24
25
19
20
21
22
16
17
18
09
10
11
06
07
08
12
13
14
15
180
Appendix
X1 & Z1 also X5 to Z5
X1 to X5 read only
X1 to X5 read only
X1 to X5 read only
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 only
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 to X5 read only
X1 to X5 read only
X1 & Z1 also X5 to Z5
X1 & Z1 also X2 & Z2
X1 & Z1
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1 also X5 to Z5
X1 & Z1
X1 & Z1
X1 & Z1
X1 & Z1
X1 & Z1
X1 & Z1
X1 & Z1
X1 & Z1 also X2 & Z2
X1 read only
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL
INDIVIDUAL & IRC
INDIVIDUAL & IRC
Individual/(IRC with
2.00x or later)
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
IRC
IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
IRC from REG holding data
IRC from REG holding data
IRC from REG holding data
IRC from REG holding data
IRC from REG holding data
IRC from REG holding data
IRC from REG holding data
INDIVIDUAL & IRC
INDIVIDUAL & IRC
SPS-2000 Program Manual v1.30
19
41
45
50
45
46
47
42
43
44
Station Totals
Active Employees – time keeping
Daily Time Keeping
Shift Reporting
Inventory
PLU Stock
X1
X1 read only
X1 & Z1 also X5 to Z5
X1 & Z1
X1 & Z1
X1 & Z1
52
53
54
55
48
49
50
51
Not use this by REPORT key function.
Stock by Group
Stock by Individual Group
Food Cost
PLU Minimum Stock
Not use this by REPORT key function.
String Report 1 – as defined by program
String Report 2 – as defined by program
X1 & Z1
X1 & Z1
X1 & Z1
X1 & Z1
56
57
58
String Report 3 – as defined by program
String Report 4 – as defined by program
Custom Report
X1 & Z1*
X1 & Z1 *
X1 & Z1*
X1 & Z1*
X1 & Z1
59
60
Pre-Poll Report – Hard Copy Print Out
Not use this by REPORT key function.
X1 & Z1
61 Clocked in employees X1 read only
* Generates X/Z Level based on string report programming in PGM mode.
Report Option Table
06
14
18
PLU’s by Group for Selected Group
Individual Employees
From/To Groups
Selective Groups
Product Projections
Shift Reporting
Stock by Individual Group
IRC
IRC
IRC
INDIVIDUAL & IRC
IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL & IRC
INDIVIDUAL
INDIVIDUAL & IRC
INDIVIDUAL & IRC
OPTION
Group number (1~2 digit)
Employee number (1~3 digit)
Frome/To Group number (4 digits)
If from group number is 1 and to group number is 2, option data is 0102.
Group number (1~2 digit)
Week data (1 digit)
Shift number (1 digit)
Group number (1~2 digit)
SPS-2000 Program Manual v1.30 Appendix
181
Special Report Commands
99000 Print Super Macro (available at version 3.00y or later)
99100 Print Super Macro and Reset (available at version 3.00y or later)
98000 Save PGM/Reports to SD card (available at version 3.00g29 or later)
98100 Save PGM/Reports to USB Memory (available at version 3.00g29 or later)
182
Appendix
SPS-2000 Program Manual v1.30
Glossary of Terms
Activity Count
The activity counter keeps track of the number of times an entry is made on a PLU, or function key.
Add Check
The Add Check function is used to add multiple guest checks (tracking balances or soft checks) for payment together. (Use Tray Subtotal to add separate transactions when you are not tracking balances.)
Audaction
Refers to the total of all sales ending in a negative balance.
Authority Levels
Each employee must be assigned to one of nine authority levels. Each of the levels is set up to determine the operations that are allowed for each employee.
For example, in a restaurant an authority level with the descriptor kitchen help could be set to allow only clocking in/out, or an authority level with the descriptor owner could be set up to allow all functions. Other authority levels could be defined for servers, cashiers and managers that allow only the appropriate functions.
Auto Grill
Use the Auto Grill option to send items individual items to the designated kitchen printer. Items are sent with a one-item delay (at the next item or at subtotal.)
Auto Scale
Registrations of PLUs with auto scale status will automatically multiply by the weight placed upon a scale connected to the register. Use for items such as produce that are always sold by weight.
SPS-2000 Program Manual v1.30 Glossary of Terms
183
Auto Tare
With auto tare status assigned, a preprogrammed tare weight will automatically subtract from the weight from the scale.
Bitmap File
The bitmap file is an image, i.e. a logo that can be printed on a receipt or guest check. The bitmap file is downloaded to the SPS-2000 from a PC, and then downloaded to the memory of the appropriate printer.
Canadian Donut Law
Refers to special Provincial or State sales tax laws that change the taxable status of an item depending upon the quantity sold. Donuts, for example, might be taxable when sold individually at a bakery.
However, if a customer purchases a dozen, the food sale is considered non-taxable.
Cancel
Press the CANCEL function to abort a transaction in progress. All current items are removed
(voided).
Check Cash
Use the CHECK CASH function to exchange a check for cash outside of a sale.
Check Endorse
If compulsory check endorsement is set with the CHECK key, use the CHECK ENDORSE function to print the endorsement message after a check is inserted into the appropriate printer.
Compulsory
When an operation is programmed compulsory, a function (i.e. Non-add number entry) must be performed in order to complete the operation.
Condiment
Condiments PLUs are different from non-condiment PLUs in the manner they display and print during operations. Non-condiment PLUs are used for "main" items. Condiment items are indented and displayed/printed below a main item so that condiments or cooking instructions are easily understood for each "main" item.
Continue
Use the Continue function to override the pop-up employee function after a transaction. Allows the employee to post an additional transaction without signing on again.
184
Glossary of Terms
SPS-2000 Program Manual v1.30
Currency Conversion
Use one of the 5 available currency conversion functions to convert and display the value of the transaction in foreign currency. Only cash tender is allowed after pressing a CURR CONV key.
Change is calculated and issued in home currency.
Custom Report
One custom report can be created, with up to 50 totals and counters. The report is built by selecting totals that also appear on either the financial or sales by time period reports. When the custom report is created, totals and counters separate from the original report are also created (in other words, you can clear either the custom independently without affecting totals in any other report.)
Another feature of the custom report is the ability to add or subtract selected totals to create a new subtotal of selected information.
Default Program
The original program installed in the ER-550. The register has a default program, which makes it operational after a RAM clear. Nearly all option, rate, and status programs are set to zero as the default condition.
Destination
Refers to the destination for the sale i.e. eat-in, take out, drive thru.
Discount (Item)
An item discount (coupon or %) subtracts an amount or percentage from the price of an item. This subtraction nets the Department or PLU total.
Discount (Sale)
A sale discount (coupon or %) subtracts an amount or percentage from the entire sale.
Electronic Journal
The electronic journal is an area of memory designated to keep a sales journal. The electronic journal can be printed, if necessary, to provide a traditional record of all register activity.
Error Condition
An error condition signals that an incorrect operation has occurred. It is identified by an audible tone and an error descriptor appearing on the display.
Error Correct
An error correct operation voids the last item entered, it must be used within a sale.
SPS-2000 Program Manual v1.30 Glossary of Terms
185
Food Stamps
In the United States, Food Stamps may be used to purchase eligible food items at food stores that participate in the program. The SPS-2000 can assist a retailer in handling food stamp transactions by sorting food stamp and non-food stamp eligible items within each sale and tracking food stamp payments for eligible items.
Gallonage
Gallonage is a status that can be assigned to a PLU. Gallonage PLUs accept a price, but print both the price and the quantity of gallons sold. The quantity of gallons is computed from the price per gallon, which is set as the preset price.
Groups
Groups are totals that collect information from designated PLUs. For example all PLU dessert items could collect in a group total called "desserts". You can send each PLU to up to three groups. The first group is designated in PLU programming, the second and third groups are designated in PLU
Status Group programming.
HALO
The high amount lock-out (HALO) limits the amount allowed to be entered in a PLU, or function key.
Ingredient Inventory
A menu-explosion type inventory system is set up when PLUs are linked to a recipe number. The X-
MODE MANAGER MENU provides functions to receive, transfer in/out, or enter raw waste for ingredients used in the recipe system.
Initial Clear
The initial clear function allows you to exit any register activity and return to a beginning or cleared state. Any transaction that is in progress will be exited and totals for that transaction will not be updated.
IRC
Inter Register Communications (IRC) is the term used to describe communications within a network of registers. Information exchanged between registers includes check information for posting to guest check, information to be printed or displayed at printers or videos, and sales information for consolidated reporting.
The SPS-2000 uses ETHERNET at 10Mbps for IRC.
Job Codes
Job codes are used to break down the hours worked for all employees into different categories (See
"Labor Groups" report in the Operation Manual.) A breakdown of hours by job is also reported for each employee (See "Time Keeping" reports in the Operation Manual.)
186
Glossary of Terms
SPS-2000 Program Manual v1.30
Keyboard Level
Each keyboard level is a separately defined set of keyboard functions for each key on the keyboard.
For example, separate levels might be required for different lunch/dinner menus. Or, within a restaurant different keyboards might be set up for pre-check, bar and/or cashier stations. Each register might contain the functions for each station on a separate level, so that any register could function at any station by simply changing keyboard levels and key legend sheets.
The SPS-2000 has five keyboard levels.
Link PLU
If you wish the registration a PLU to automatically cause the registration of another PLU, enter the number of the PLU you wish to register automatically in the LINK PLU field of the appropriate PLU
Status Group.
Macro
Macros record key sequences for later execution. Up to 40 macros may be recorded and executed by pressing a function key or by entering the appropriate macro number and pressing a function key.
Memory Allocation
Memory allocation is a program that determines how the system memory is divided to provide the correct features for your application. For example, you may require more or less employee memory,
PLUs, or reporting. Memory allocation allows you to maximize the features you need while minimizing the features you do not need.
Modifier
Preceding a PLU entry, a modifier key changes a digit of the PLU number, causing a different PLU to be registered. Modifier keys can be set to change any of the 14 PLU digit positions to any specified digit (0-9). More than one modifier key can be pressed in succession to alter the PLU code.
No Sale
No sale is an operation to simply open the cash drawer.
NON-PLU Code
The NON-PLU Code program must be set if you wish to scan UPCs (using the EAN 13 code) with embedded prices, weights or quantities.
Within the EAN 13 code, the first two digits (part a) are used as an identifier and the last digit (part c) is used as a check digit. The remaining 10 digits (part b) contain the product code and the price (or weight or quantity).
Override
Override is an operation used to bypass a programmed price or HALO.
SPS-2000 Program Manual v1.30 Glossary of Terms
187
Password
A four-digit password can be set to control access to reports. Different passwords can be set for X and
Z1, Z2 etc. reports.
A system password can be set to allow service access to all of the functions of the SPS-2000. For example, use the system password if you are servicing a users system and you do not know an employee code that allows you to access necessary functions, or if authority level programming prohibits you from accessing functions you need to access in order to complete your tasks.
Piece Count
The piece count is the value assigned to a PLU item that represents the number of unit pieces sold when the PLU is registered. For example, the number of pieces of chicken can be counted when a chicken dinner is sold. The number of units set as the piece count will be reflected in product mix reporting.
PLU Status Link #
Also referred to as PLU Status Group. The status link # contains the many of the configurable options for a PLU.
PLUs
Price look-ups (PLUs) are used to register items. PLUs can be fixed keys on the keyboard or they can be accessed by indexing a code number and pressing the PLU key. PLUs can be programmed with a preset or open price. PLUs record their own activity count and dollar total on any of the PLU reports.
Post Tendering
The Post Tendering feature allows the operator to use the register to compute change on cash transactions after the sale has been finalized.
To calculate change due after finalizing the sale, enter the cash amount presented by the customer and then press CASH. The amount of change due the customer is then displayed, and the cash drawer may open.
This is a calculation function only, and no totals or counters are updated by the use of this feature.
Price Level
Prices may be assigned at up to five different price levels for each item. One of up to 20 price level keys is identified for each different PLU price.
Product Mix Groups/Product Mix Reporting
Product Mix Groups can be used to implement a simplified ingredient system for tracking only essential ingredients associated with items (i.e. cups for beverages or number of pieces for chicken menus.)
Product mix groups also report usage by time period and optional Product Projections reporting is also available. The Product Projection report provides a history of each item's sales by day of week.
188
Glossary of Terms
SPS-2000 Program Manual v1.30
Promo
The PROMO operation allows items to be sold without cost, i.e. buy two, and get one free. PROMO activity will remove the item cost from the sale, but the sales count will include the promo item.
Receipt
A receipt is a printed tape given to a customer as a record of the sale transaction.
Recipe #
A menu-explosion type inventory system is set up when PLUs are assigned to a recipe number.
Register Number
The register number is a programmable number, which prints on the receipt and journal tapes. It identifies the electronic cash register the sale or report was performed on.
Stay-Down
When a function is programmed as a stay-down function, it is valid until changed. For example, a staydown clerk remains signed on until either signed off, or another clerk is signed on.
Stock PLU
Stock PLUs track the quantity of the PLU item in stock. Each time the PLU is registered, a whole unit subtracts from the stock counter. (Note that if multiplication or decimal multiplication is used when the PLU is registered, the resulting quantity of activity will subtract from the stock counter. Stock is maintained increments to the second decimal position, i.e. "X.XX".)
Surcharge (Item)
An item percent surcharge adds a percentage to the price of an item. This addition nets the PLU total.
Surcharge (Sale)
A sale percent surcharge adds a percentage to the entire sale.
Tare Weight
A tare is the amount of weight accounted for by the container or packaging. By entering a tare weight
(as required by law in some areas) the weight of the container is subtracted and only the true weight of the product is measured on the scale.
Tax Except
Tax except is used to exclude the tax from an entire sale.
SPS-2000 Program Manual v1.30 Glossary of Terms
189
Tax Shift
Tax shift keys are used to reverse the tax status of a PLU entry.
Tender
The method of register operation in which payment is made and the transaction is finalized.
Transaction Number
A count appears at the bottom of each receipt and after each transaction on the journal tape. This count increases by one with each transaction, report, or scan.
Void
A void operation will erase a previous item entry. It must be used inside of a sale only.
Waste
The Waste function is used to start and end entries of items that are wasted. A waste count is maintained for each item and inventory is adjusted.
190
Glossary of Terms
SPS-2000 Program Manual v1.30
Index
#
#/NO SALE 58, 99
%
%1 - %10 58, 100
A
ADD CHECK 56
Authority Level link to 128
B
batch
KP/KV 117
Buffered receipt 119
C
CANCEL 56
CASH 56
Cash declaration compulsory 123
Cash Drawer Options 112
Cashier See Employee:programming
CHECK 56, 98
CHECK CASH 56, 98
CHECK ENDORSE 56, 98
CLEAR/ESC 56, 98
Clerk See Employee:programming
CONTINUE 56, 98
CURR. CONV. 1-5 56, 98 currency symbol 119
D
destination enforce 106
SPS-2000 Program Manual v1.30
direct multiplication 107
DONE 56, 98
DRIVE THRU 56, 98
E
E.J. & Detail Printing Options 125
EAT-IN 57, 98
Electronic Journal 125 embedded price PLUs 86
Employee job code 128
Pay rate 128 programming 127
EMPLOYEE 57, 98
EMPLOYEE (1-10) 57, 98
Enforce destination 106
ERR.CORR 57, 98
F
FD STMP SHIFT 57, 98
FD STMP SUBTTL 57, 98
FD STMP TEND 57, 99
Function Key programming 97
G
General Function Options 106
General Printing Options 119
GUEST # 57, 99
H
HOLD 57, 99
I
Ingredient edit 137
Index
191
J
Job Code 128
K
Keyboard Key Relocation 49 keyboard level 113
Kitchen Printing/Video Options 116
KV Routing 151
L
Level/Modifier Options 113
LIST CHECK 1-4 57, 99
M
MACRO # 57, 99
MACRO 1 - 40 57, 99
Manager control 106
MDSE RETURN 58, 99
Memory Allocation 45
Memory Clearing, selective 43
Messages 142
MISC TEND # 58, 99
MISC TEND 1-16 58, 99
MODIFIER 1-10 58, 99
Modifier/Size 103
O
Open drawer alarm 112
P
P/BAL 58, 99
PAID OUT 1-5 58, 100
PAID RECALL 58, 100
PARK ORDER 61
Pay rate 128
PLU embedded price 86
Function key 58, 100
Programming 76 preamble/postamble guest check 120 price embedded PLU 86
PRICE INQ 58, 100 price level 113
PRICE LVL 1-20 58, 100
PRINT (function key) 58, 100
PRINT CHECK (function key) 59, 100
PRINT HOLD 59, 100
Printer Driver Selections 66
Priority printing 116
192
Index
Product Mix Group Time Periods 139
Product Mix Groups 138
Program Scan
P-Mode 154
PROMO 59, 100
Q
QUIT (function key) 59, 100
R
real time
KP/KV 117
RECALL CHECK # 1-4 59, 100
RECD ACCT 1-5 59, 100
RECEIPT 59, 100
RECEIPT ON/OFF 59, 100
Recipe Table 138
REPEAT 59, 100
Report Options 123
Report Printing Options 122
S
SCALE 59, 100
Screen Saver 108
SEAT # 59, 100
Serial Port Device Selections 67
SERVE ORDER 61, 101
Server See Employee:programming
Size/Modifier 103
SPLIT PAY 59, 100
STOCK INQ 60, 100
STORE CHECK 1-4 60, 101
SUBTOTAL 60, 101
System Options
Cash Drawer Options 112
E.J. & Detail Printing Options 125
General Function Options 106
General Printing Options 119
Kitchen Printing/Video Options 116
Level/Modifier Options 113
P-Mode 105
Report Options 123
Report Printing Options 122
S Mode 63
Tax Options 111
Time Keeping Options 124
Tracking File Options 114
Training Mode Options 113
Validation/Subtotal Print Options 118
SPS-2000 Program Manual v1.30
T
TABLE # (1-4) 60, 101
TAKE-OUT 60, 101
TAX EXEMPT 60, 101
Tax Options 111
TAX SHIFT 1-6 60, 101
Taxes programming 140
Time Activated Functions programming 135
TIME IN/OUT 60, 101
Time Keeping Options 124
TIP (1-3) 60, 101
TIP DECLARE 56
Tracking File Options 114
Training Mode Options 113
TRANSFER CHECK (1-4) 60, 101
TRAY SUBTL 60, 101
V
VALID 60, 101
Validation/Subtotal Print Options 118
VAT subtracted fm indiv PLU ttls 111
VOID ITEM 60, 101
W
WASTE 60, 101
SPS-2000 Program Manual v1.30 Index
193
Manual Revision Record
Edition
V1.1
V1.2
V1.3
V1.4
V1.5
V1.6
V1.7
V1.8
V1.9
V1.10
V1.11
V1.12
V1.13
V1.16
V1.17
V1.18
Date published
9/5/06
9/22/2006
9/26/2006
11/16/2006
12/19/2006
3/29/2007
5/1/2007
6/6/2007
6/29/2007
7/12/2007
8/30/2007
9/24/2007
10/19/2007
5/14/2008
6/26/2008
11/10/2008
Revision contents
Add features associated with software V2.00c/d
Add features associated with software V2.00g
Add features associated with software v2.00i
Add features associated with software v2.00l; New
TPFT Server Instructions
Add features associated with software V2.00t
Add features associated with software V2.00x/2.01b
Add features associated with software V2.01n; O/S upgrade from SD requires Bootrom V1.10
Add features associated with software V2.01r; clarify function of KP Routing key; IRC of “Employee
Signed On” report available at 2.00x or later
Use CLEAR to exit Paid Recall p53
Explanation of “Number of Choice” field p48
Correct function list file name is flist_imgxxx.jpg p32
P 48. Table management flag available; provide link to program guide – Repair page break at pg. 144/145.
Add features associated with software V2.02n
Add features associated with software V2.03k
Add features associated with software V3.00c
Add Features associated with software V3.00w. Fixed
Keys: DONE, PLU, PREV. X/TIME/SUBTOTAL/
CLEAR, CASH and VOID ITEM are now macros, and may be reassigned through macro programming.
194
Manual Revision Record
SPS-2000 Program Manual v1.30
V1.19
V1.20
V1.21
V1.22
V1.23
V1.24
V1.26
V1.27
V1.28
V1.30
2/10/2009
7/24/2009
9/29/2009
10/06/2009
1/07/2010
3/08/2010
10/10/2010
1/17/2011
6/24/2011
9/22/2011
Corrected tax threshold definition, Report Option #14 definition
Added S/SELF TEST/NETWORK PING TEST
PLU code length 17 digits (incorrectly identified as
14 digits); clarified P/Bal function.
Added precaution pages
“logo.jpg” file must be lower case.
Updated Default System Descriptors; California
Drivers License Info added.
REPORT function key commands added. Error
Message & System Descriptors updated.
S-Mode System Options updated. USB stick Update methods added.
Added features associated with v.3.00g30 application software release.
Updated KV Routing Download note on page 156.
Updated PLU inactive status definition. Time activated String Report to FTP information added.
SPS-2000 Program Manual v1.30 Manual Revision Record
195
Advertisement
Key features
- High-resolution graphical LCD display for clear and intuitive navigation
- Multiple payment options including cash, credit/debit cards, and mobile payments
- Built-in Wi-Fi and Ethernet connectivity for seamless data transfer and remote management
- Advanced inventory management system with real-time stock tracking and alerts
- Robust reporting and analytics tools for data-driven decision-making
- Sleek and compact design for space optimization
- Reliable performance and long-lasting durability