Eclipse ThermJet Burners
Datasheet 205-2.5
2/11/2013
Eclipse ThermJet
Burners
Model TJ0040
Version 2.7
Parameter
Burner Velocity
Model TJ0040
Maximum Input, Btu/h (kW)
Medium & High Velocity
400,000 (117)
Minimum Input On-Ratio, Btu/h (kW)
Medium & High Velocity
40,000 (11.7)
Minimum Input Fixed Air, Btu/h (kW)
Medium & High Velocity
10,000 (2.9)
Gas Inlet Pressure Required, "w.c. (mbar)
Tap B (see page 3)
High Velocity
Medium Velocity
Air Inlet Pressure Required, "w.c. (mbar)
15% Excess Air at Maximum Input
Tap A (see page 3)
High Velocity
Medium Velocity
High Fire Flame Length, inches (mm)
Measured from the outlet end of the combustor
High Velocity
Medium Velocity
Approximate Flame Velocity, ft/s (m/s)
15% Excess Air at Maximum Input
Natural Gas
12.0 (29.9)
Propane
13.0 (32.4)
Butane
12.0 (29.9)
Natural Gas
5.5 (13.7)
Propane
5.5 (13.7)
Butane
5.0 (12.5)
Natural Gas
15.5 (38.6)
Propane
17.0 (42.3)
Butane
17.0 (42.3)
Natural Gas
9.0 (22.4)
Propane
9.5 (23.7)
Butane
9.5 (23.7)
Natural Gas
14.0 (356)
Propane
17.0 (432)
Butane
17.0 (432)
Natural Gas
18.0 (457)
Propane
19.0 (483)
Butane
19.0 (483)
High Velocity
540 (165)
Medium Velocity
320 (98)
Maximum Combustion Air Temperature
300°F (149°C). For higher temperatures use TJPCA (Datasheet 206).
Flame Detection
Flame rods can be used with all combustors, natural gas, and
operating temperatures up to 2,200°F (1,204°C).
UV scanners can be used with all combustors, any fuel listed below,
and up to the maximum operating temperature.
Fuel
For any other mixed gas, contact Eclipse, Inc.
Natural gas, propane or butane1
Approvals
1. See Design Guide 205 for more information about typical fuel composition and properties
• All information is based on laboratory testing in neutral (0 "w.c., 0 mbar) pressure chamber. Different chamber conditions may affect
the data.
• All information is based on standard combustor design. Changes in combustor will alter performance and pressures.
• All inputs based upon gross calorific values and standard conditions; 1 atmosphere, 70°F (21°C).
• Eclipse reserves the right to change the construction and/or configuration of our products at any time
without being obliged to adjust earlier supplies accordingly.
• Plumbing of air and gas will affect accuracy of orifice readings. All information is based on
generally acceptable air and gas piping practices.
Performance Graphs
NOX Emissions
Ignition & Operational Zones
(High Velocity Combustor)
90
10,000
80
70
NOX ppm (@ 3% O2)
% Excess Air
Ignition and
Operational Zone
1,000
100
60
50
40
30
20
NOX Natural Gas
NOX Propane/Butane
10
10
0
0
100
200
300
400
0
100
Input (x 1,000 Btu/h)
0
30
200
300
400
90
120
Input (x 1,000 Btu/h)
60
90
120
0
30
60
Input (kW)
Input (kW)
Emissions correction factor for medium velocity combustor is
1.20. Emissions data based on, on-ratio control firing at 15%
excess air corrected to 3% O2.
Emissions from the burner are influenced by:
• Fuel type
• Combustion air temperature
• Firing rate
• Chamber conditions
• Percent of excess air
For estimates of other emissions, contact Eclipse.
Fuel Orifice ∆P vs. Input
6
5.0
15.0
∆P (mbar ± 5%)
7.5
∆P ("w.c. ± 5%)
∆P (mbar ± 5%)
10.0
Natural Gas ∆P - 10.8 mm orifice
Propane ∆P - 9.1 mm orifice
Butane ∆P - 9.1 mm orifice
5
12.5
Air Orifice ∆P vs Input
(∆P Measured Between Taps A and C)
15% Excess Air at Maximum Input
4
3
12.5
10.0
7.5
4
3
2
5.0
2
2.5
1
2.5
1
0
0
0
0
0
100
200
300
400
Air Orifice (37 mm)
5
∆P ("w.c. ± 5%)
15.0
(∆P Measured Between Taps B and D)
0
30
60
Input (kW)
2
90
120
200
300
400
Input (x 1,000 Btu/h)
Input (x 1,000 Btu/h)
0
100
0
30
60
90
120
Input (kW)
Eclipse ThermJet TJ0040, V2.7, Datasheet 205-2.5, 2/11/2013
Dimensions and Specifications
Dimensions in mm (inches)
Burner Housing
Ø6.4
(161.8)
4x Ø12 (0.5)
Ø136
(5.4)
225
(8.9)
8
(0.3)
1/2" NPT
Flame Rod
or UV
Scanner
Adapter
177
(6.97)
96
(3.8) 89.9
(3.5)
Spark Plug
M14
2" NPT
or BSP
(Air Inlet)
3/4" NPT
or BSP
(Fuel Inlet)
85
(3.4)
166
(6.5)
Burner weight less combustor: 21.6 lbs (9.8 kg)
Tap Locations
Tap C
Tap A
Tap D
Tap B
Eclipse ThermJet TJ0040, V2.7, Datasheet 205-2.5, 2/11/2013
3
Dimensions and Specifications
Dimensions in mm (inches)
Combustors
Ø162
(6.4)
4 x Ø12 (0.5)
Alloy Combustor (AISI 310)
Weight: 2.1 lbs (0.95 kg)
Maximum Chamber Temp: 1,750°F (950°C)
Ø89
(3.5)
H: 213 (8.4)
M: 194 (7.6)
Ø136 (5.4)
Ø162
(6.4)
10
(0.4)
4 x Ø12 (0.5)
Silicon Carbide Combustor
Weight: 3.6 lbs (163 kg)
Maximum Chamber Temp: 2,500°F (1,371°C)
Ø95
(3.7)
Ø136 (5.4)
230 (9.1)
Ø218 (8.6)
6
(0.2)
4 x Ø12 (0.5)
Ø146
(5.8)
Refractory Combustor with AISI 330 wrapper
Weight: 14 lbs (6.4 kg)
Maximum Chamber Temp: 2,800°F (1,538°C)
180
(7.1)
230
(9.1)
Exhaust Outlet Diameter:
High Velocity: Ø42 (1.7)
Medium Velocity: Ø60 (2.4)
Datasheet 205-2.5, 2/11/2013
Ø191 (7.5)