Fujitsu Multiroom Systems

Fujitsu Multiroom Systems
Fujitsu
Multi Room System
Connect 2, 3 or 4 indoor units
to a single outdoor heat pump
NOW YOU CAN CONTROL
YOUR HOME COMFORT FROM
YOUR SMARTPHONE
The Home Comfort Specialist
SMART
PH
CONTROONE
L
AVAILA
BLE NO
W!
Multi Room Systems
The Fujitsu Inverter Multi System is the ideal way to have heating or cooling in more
than one room, for example a living room and 3 bedrooms.
The choice of systems allows a wide variety of 2, 3 or 4 indoor units to be connected to just 1 outdoor unit and you can tailor your
own combination of hi wall, floor console, cassette or bulkhead to best suit each room. Our product range includes 5 indoor unit
types spanning 12 models ranging in capacity from 2.0kW to 7.1 kW. With such a diverse choice of options there is a combination
to suit most homes or small businesses in New Zealand.
All the heat you need
A fresher, healthier home
Fujitsu engineering delivers all the heat you need just when
you need it. You’ll be as warm as toast even when it’s
freezing cold outside, wherever you live in New Zealand. The
reverse cycle uses the same engineering to cool and
dehumidify your home environment in summer.
Fujitsu’s advanced air purifying and
deodorising filters on most models absorb
minute dust particles, invisible mould spores,
pollen and other harmful micro organisms. This
will give you a healthier home environment,
which is why Fujitsu is recommended by
Asthma New Zealand.
Quietly does it
Quiet Mode
(21 - 30 decibels)
Brilliant fan technology, plus
‘quiet mode’ on most Fujitsu
models means that noise is
not an issue with Fujitsu.
Compare our decibel levels
(see back of this brochure)
and you will see that even our larger heat pumps operating
on full capacity are usually quieter than any other brand in
New Zealand. Whisper quiet is a Fujitsu fact - not just an
advertising claim.
Smartphone control
The new PebbleAir™ from Fujitsu
allows you to control your Fujitsu
from your smartphone or tablet.
That means you can turn your heat
pump on when you aren’t at home,
check and control the temperature and add a 7-day
‘set-and-forget’ timer function to older Fujitsu models that
didn’t previously have that feature.
The PebbleAir™ will work with Fujitsu’s multi systems,
although you will need one PebbleAir™ for each indoor heat
pump you wish to control.
Now you’ll always come home to a warm welcome!
Only Fujitsu is
recommend by
Asthma
New Zealand
The importance of installation
Fujitsu have the only accredited
installer scheme in New Zealand. That
means when you choose an installer
who has achieved Fujitsu
Accreditation, you can be assured of
a professional installation (plus you will
also get a full 6-year parts and labour
warranty - New Zealand’s longest).
Check our website for FAQ’s, detailed information on how
heat pumps work and our full range of models.
Independent Control
Flexible installation
Each indoor unit can be operated
independently. This means that
on / off, temperature, air
movement, and time / clock
operation can all be controlled
from their own controller. (The
multi system cannot be operated
in heat and cool mode
simultaneously).
Fujitsu Multi systems can be installed in large buildings
and over multiple floors due to the long maximum
allowable pipe length.
Maximum Pipe length
(each unit):
25m (AOTG24LAT3/30LBTA4)
Max. Height:
15m (AOTG24LAT3/30LBTA4)
UTY-RVNYN
4 Outdoor Units
Single Splits
vs 1 Outdoor Unit
Multi
Total Piping Length:
50m (AOTG24LAT3)
70M (AOTG30LBTA4)
Innovative technology
High efficiency / low noise large fan
Newly designed fans have been used to
increase airflow efficiency, at the same
time as significantly reducing sound
pressure
Heat exchanger
A new 3 row heat exchanger has
been used which allows for a more
compact outdoor unit with higher
energy efficiency.
DC fan motor
High performance and high efficiency
has been achieved by using a new
smaller DC Fan Motor.
High efficiency DC Twin Rotary
Compressor
A high performance, low noise, large
capacity DC Twin Rotary Compressor
is used.
10˚C heat operation
Economy operation
Operation starts and maintains the room temperature at
10˚C when the temperature drops below 10˚C.
By maintaining a slightly higher temperature in cool
mode, lower temperature in heat mode and limiting the
maximum current draw real energy savings are achieved.
20°C
10°C
NB When the room
temperature is
higher than 10˚C,
“10˚C HEAT”
operation does
not start.
Normal operation
Setting
temperature
Economy operation
Time
Bulkhead Type
ARTG09/12LL✴
Floor/Ceiling
ABTG18LVT✴
Compact Cassette Type
AUTG09/12/18LVL✴
Bulkhead Type
ARTG18LL✴
Hi-Wall Type
ASTG18/24LFC✴
AOTG24LAT3
H 8.00kW
C 6.80kW
AOTG30LBTA4
H 9.60kW
ASTG07LVCA/09L/12LVCC
ASTG18L/24LFC✴
ABTG18LVT✴
AUTG09L/12L/18LVL✴
ARTG09L/12/18LLT
Model No.
2-3
Rooms
2,3,4
Rooms
Hi-Wall Premier Plus
ASTG09/14LUCB✴
C 8.00kW
• • •
•
• •
• • • • •
• • • • •
•
• •
ASTG09/14LUC✴
•
•
•
•
•
•
Compact Hi-Wall Premier
ASTG07/09/12LVC✴
•
•
•
•
•
•
•
•
•
•
•
• •
•
• •
•
•
• • • • •
• • •
• • •
•
Included Function
• •
Optional Function
Hi-Wall
Premier Plus
Compact Hi-Wall
Premier
Hi-Wall
Premier
Floor / Ceiling
Compact Cassette
Slim Duct
ASTG09-14LUC✴
[M]
ASTG07-12LVC✴
[M]
ASTG18-24LFC✴
[M]
ABTG18LVTA✴
[M]
AUTG09-18LVL✴
[M]
ARTG09-18LLT✴
[M]
BTU Class
09
14
07
09
12
18
24
18
09
12
18
09
12
18
kW Class
2.5
4.0
2.0
2.5
3.5
5.0
7.0
5.0
2.5
3.5
5.0
2.5
3.5
5.0
•
•
• • • •
• • • •
•
•
-
•
•
• • • • • •
• • • • • •
AOTG24LAT3
AOTG30LBTA4
•
—
—
ction.
Output
—
—
Priority
Fresh
air control
Emergency
stop
Operationheater
status
Auxiliary
Error status
Preparation
Fresh air control
Output
●*2
● *2
Auxiliary heater
Preparation
—
—
●
—
—
—
—
—
—
—
—
—
—
—
●
●
—
●—
—
—
●
1
—
—
—
● ●●
●*2 ●●
● *2 —
—
—
—
● —
●*
● —
—
—
—
●*2
● *2
—
—
—
—
—
—
—
—
* 1 : Duct type does not have this function.
* 1 : Duct type does not have this function.
* 2 : Cassette
and Ceiling
type
does
notthis
have
this function.
* 2 : Cassette
and Ceiling
type does
not have
function.
Controller & options
Controllers
Controllers
For Individual & Centralised Control
LCD
Controller Control
Wired
Remote Controller
For Individual
& Centralised
Wired Remote Controller
Wired Remote Controller
Simple Remote
Controller
Simple Remote Controller
Wired Remote Controller
Wired Remote Controller
Wired Remote Controller
UTY-RVNYN
UTY-RNNYN
Remote Temperature Sensor
IR Receiver Kit
For Duct type
UTY-RVNYN
UTY-RNNYN
For Cassette type
UTY-RNNYN
UTY-RSNYN
+
UTY-RVNYN
UTY-RNNYN
Temperature
Sensor
IRUTY-XSZX
Receiver
Unit
IRRemote
Receiver
Kit / UTD-RS1OO
New amenity space can be offered by installing
For
Duct Communication
type
the Remote
sensor.
Kit
For Compact Wall Mounted type
UTY-RSNYN
UTY-RSNYN
AR-RAH1E/AR-RAH2E/AR-REA1ED
Remote Temperature
IR
Receiver
Kit External
Louver
Grill
Control Kit
UTY-LRHYM
UTY-LRHYA2
Receiver
Kit
ForIR
Duct
type
For
Auto Louver Grille
KitCassette
External Connect Kit
type
External Connect Kit
+
IR Receiver
Kit
Sensor
For
For Indoor
UnitCassette
+
UTY-XSZX / UTD-RS1OO
External Connect Kit
UTD-GXSA
UTD-GXSB
UTD-GXSA/UTD-GXSB
Communication Kit
Communication Kit
External Control Set
UTD-E
For Outdoor unit
UTY-LRHYA2
UTD-ECS5A
UTY-XWZX/UTY-XWZXZ5
UTY-XSZX
UTY-LRHYA2
External Connect Kit For Outdoor unit
Auto Louver
Grille
Kit Kit
UTY-XWZXZ2
Fresh Air Intake
UTY-XWZXZ3
Fresh Air Kit
Function list
For Indoor unit
UTY-XWZX
UTY-XWZXZ3
●
UTY-XWZXZ2
Control
Peak cut
Low noise
For Indoor unit
Priority
UTY-XWZX
UTY-XWZXZ5
Function list
UTY-TWBXF
●
UTY-XCBXZ1
UTY-TWBXF
For Compact Wall Mounted
LVCA
type
UTD-GXSA
For Compact Wall Mounted
LVCC/ LUCB type
—
—
—
—
—
—
Universal Controller
●
UTY-XWZXZ2
UTY-XWZXZ4
—
●
●
—
—
—
●
●
●
●
●
—
For Cassette type
UTZ-VXAA
UTZ-VXGA
Indoor Units
Model
Compact Wall Mounted
Compact
SlimFilter
Duct
Long-Life
Cassette
UTY-RVNYN
UTY-RNNYN
AR-RAH2E
Wireless Remote
Controller
●
—
—
—
Controllers LVCA
LVCC LUCB
For Individual & Centralised Control
LCD Universal Controller
UTD-ECS5A
—
—
—
—
For Outdoor unit
—
—
UTY-XWZXZ3
UTY-XWZXZ2
●
UTD-GXSA
For Compact Cassette type
UTD-GXSB UTZ-VXAA
UTD-GXSB
Type
●
For Outd
UTY-XWZXZ5
—
—
—
UTD-ECS5A
Input
Control
Peak cut
Low noise
Priority
Input
For Ind
For Indoor Unit
UTY-XWZXZ5
UTY-LRHYM UTY-XWZXZ5
UTY-XWZX
UTY-LRHYM
type
External Control Set
For Indoor Unit
UTY-XWZX
UTY-TWBXF
For Compact Wall Mounted type
Auto
Louver Grille Kit
Simple Remote Controller
UTY-RSNYN
IR Receiver Kit
New amenity space can be offered by installing
the Remote sensor.
UTY-LRHYM
Communication Kit
Wireless Remote
Controller
Simple Remote Controller
AR-RAH1E
*1
*2
*2
*1
*2
*2
Wired Remote Controller
•
Controllers
For Individual & Centralised Control
Wired Remote Controller
Wired Remote Controller
•
•
•
Simple Remote Controller
UTY-RSNYN
•
Remote Temperature Sensor
UTY-XWZX
the Remote sensor. UTD-LF25NA
UTD-LF60KA
UTY-RVNYN
UTY-RNNYN
Remote Temperature Sensor
New amenity space can be offered by installing
the Remote sensor.
Drain Pump Unit
UTY-XWZXZ5
UTD-GXSA
Louver Grille
UTD-GXSB
UTZ-VXAA
Remote Temperature Sensor
UTY-XSZS
*1
Communication Kit
*2
*2
Wired Remote Controller
•
UTY-XSZX / UTD-RS1OO
Communication Kit
+
•
Simple Remote Controller
600
IR Receiver Kit
For Duct type
IR Recei
For Cass
UTG-AGYA-W
UTY-RSNYN
+
IR Receiver
Kit
For Cassette type
UTY-LRHYM
*2
Auto Louver Grille Kit
UTY-LRHYM
UTY-LRHYA2
Auto Louver Grille Kit
UTY-TWBXF
Included with unit
Optional
UTZ-PX1NBA
•*1 Optional
Communication Kit (UTY-XCBXZ1) is necessary for the installation *2 UTY-TWBXF is necessary for the installation
UTY-TWBXF
Simple R
Drain Pump Unit
For Compact Wall Mounted type
For Compact Wall Mounted type
Fresh Air Kit
IR Receiver Kit
*1 Duct type *2
For
UTY-XSZX / UTD-RS1OO
External Control Kit
Ceiling
UTY-RNNYN
New amenity space can be offered by installing
UTY-LRHYM
Floor /
Panel
LF
UTY-RVNYN
AR-REA1ED
IR Receiver Unit
Wall
Wide
Mounted
UTD-GXSA
UTD-GXSB
UTD-GXSA
UTD-GXSB
UTR-DPB24T
Smart control for more convenience and better economy options.
LCD Wall Controller (UTY-RVNYN)
Universal Wall Controller (UTY-RNNYN)
NEW!
This smart optional controller is simple to
use, yet has many features to add more
control to your comfort with greater
efficiency and convenience.
Features:
• Includes all the control functions of
the already supplied controller
• Backlit display
UTY–RVNYN
• Includes all the control functions of the already
supplied controller
• 7-day programmable timer with 2 x auto on/off
scheduling possible for each day
• Set-back timer, allows different temperature
settings for each day
• Economy mode, saves energy by limiting
maximum output
• Child lock
• Memory back-up (instant re-set) - remembers
settings in case of power outages
• Clean filter indicator
• 7-day programmable timer: with 8 x auto on/off
scheduling possible each day
• 2 weekly settings – so can be programmed for winter
and summer
• Auto-off timer – automatically turns
off if left on accidentally
UTY–RNNYN
Features:
• Clear function display with symbols and descriptions
to show settings to first time users
WORLD FIRST
• Temperature Limit Select – to limit maximum
and minimum temperature settings
• Auto Return set temperature –
WORLD FIRST
temperatures can be set to return
to pre-set values after a pre-set time. Prevents
temperatures being set too high or too low.
Wireless Controllers
• Operation features can be removed or added –
this allows full customisation of controller to suit
applications like hotels, motels that do not require
some features, or to simplify
(AR-RAH1E/AR-RAH2E/AR-REA1E)
These remote controllers offer:
• Economy mode – allows the unit to operate at
reduced settings to improve running costs.
• 24 hour programmable timer,
which is easy to set
• 3 types of lock-out operation: child lock; partial lock
and management lock
• Four standard timers (On/Off/
Programme/Sleep Timers)
• Memory back-up
• Easy, convenient operation
• Clean filter indicator
• Easy to change modes: heating/cooling/dry/auto/fan
AR-RAH1E/AR-RAH2E/AR-REA1E
• Weekly timer ability for controller AR-REA1E
OPTIONAL
PARTS
Simple Wall Controller (UTY-RSNYN)
Features:
OPTIONAL
PARTS
Auto Louver
Grill (UTD-GXSA/UTD-GXSB)
OPTIONAL
PARTS
• Basic operation function
Auto Louver
Grillelouver
Kit : UTD-GXSA-W
/ UTD-GXSB-W
Simple
flat auto
will provide comfort
airflow
and harmonise with luxury interior.
• On/Off
• Mode change (heating/cooling)
UTY–RSNYN
Auto Louver Grille Kit : UTD-GXSA-W / UTD-GXSB-W
• Temperature change: Auto: 18 to 30˚C:
Heating 16 to 30˚C: Cooling 18 to 30˚C
Auto Louver Grille Kit : UTD-GXSA-W / UTD-GXSB-W
• Fan change: auto, high, medium, low, quiet
Closed louver
Closed louver
Opened louver
Opened louver
Flexible Control
Flexible Control
• Operation with
unit indoor unit
External Control Set
External Connect Kit For Indoor Unit
with
Closed
louver control
louver
Auto
Louver
is remote
operated
withOpened
remote
control
• UP and Down auto swing
• Auto
airflow
direction
and
auto
swing
Control
• UP andFlexible
Down auto
swing
• 4 selectable steps
• Operation with indoor unit
External Control Kit (UTY-XWZX/UTY-XWZXZ5)
•Autoairflowdirectionandautoswing
• Auto-closing
louver
Auto Louver is operated with remote control
When operation of• UP
indoor
is stopped,
the louver will automatically
andunit
Down
auto swing
•4selectablesteps
close.
UTY-XWZX
UTY-XWZXZ5
UTD-ECS5A
• Auto airflow direction and auto swing
External Control Set
External Connect Kit
• 4 selectable
steps
• Auto-closing
louver
forExternal
indoor
unit
forExternal
indoor
unit IndoorForUnit
• Auto-closing louver
Connect
Kit For Outdoor unit
Indoor
ForUnit
Indoor Unit
External
ControlControl
Set ForSet
Indoor Unit
External
External
Connect
Connect
Kit For Kit
Grille
When operation
indoor
unitAuto
istheLouver
stopped,
the louver
When operationof
of indoor
unit is stopped,
louver will automatically
close.
Duct type
will automatically close
• Illuminated display (on button press)
• Operation with indoor unit
Auto Louver is operated with remote control
• Operation
• UP and Down
auto swing with indoor
Fordirection
Indoor
Unitswing
• Auto airflow
and auto
Auto Louver
is operated
• 4 selectable steps
• Auto-closing louver
When operation of indoor unit is stopped, the louver will automatically
close.
Auto Louver Grille
Duct type
Wired Remote
Controller
Wireles Remote
Controller
Auto Louver Grille
UTY-XWZX
UTY-XWZX
UTY-XWZXZ5
UTY-XWZXZ5
UTY-XWZXZ2
UTD-ECS5A
UTD-ECS5A
Duct type
UTY-XWZXZ3
External
External
Connect
Connect
Kit For Outdoor
Kit For Outdoor
unit
unit
Function
Function list list
UTY-XWZXZ4
For Outdoor unitWired Remote
Controller
UTY-XWZXZ3
For Indoor unit
UTY-XWZXZ2
UTY-XWZXZ2
Control
FunctionFunction
list
listInput
Input
Control
Control
InputPeak cut Peak cut
Low noise Low noise
Priority
Priority
UTY-XWZX
UTY-XWZXZ3
UTY-XWZXZ3
●
UTY-XWZXZ5
●
UTD-ECS5A
UTY-XWZXZ4
UTY-XWZXZ4
●
Peak cut
—
—
—
Low noise
—
—
For IndoorFor
unitIndoor unit
For Outdoor
Forunit
Outdoor unit —
Priority
—
—
—
UTY-XWZXUTY-XWZXUTY-XWZXZ5
UTY-XWZXZ5
UTD-ECS5A
UTD-ECS5A
UTY-XWZXZ2
UTY-XWZXZ2
UTY-XWZXZ3
UTY-XWZXZ3
●
●
●
●
●
●
—
—
—
—
—
—
—
—
—
—
●
●
●
●
—
—
—
—
—
—
●
●
●
●
—
—
—
—
—
—
●
●
—
—
UTY-XWZXZ2
—
●
●
—
—
●
●
●
Wireles Remote
Controller
Wired Remote
Controller
Wireles Remote
Controller
Indoor units combination possibilities
The multi system is a technically advanced heat pump system. To keep design possibilities simple we have compiled tables
of the only permissible configurations, please refer to the table that will suit your situation. The total capacity of the system is
limited to the outdoor unit’s capacity and its ability to deliver to the combined indoor units.
AOTG24LAT3 combinations
AOTG30LBTA4 combinations continued
No. of Combos
BTU Total
Room 1
Room 2
Room 3
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
14
16
19
21
25
18
21
23
27
24
26
30
21
23
26
28
25
28
30
31
33
27
30
32
33
35
36
7
7
7
7
7
9
9
9
9
12
12
12
7
7
7
7
7
7
7
7
7
9
9
9
9
9
12
7
9
12
14
18
9
12
14
18
12
14
18
7
7
7
7
9
9
9
12
12
9
9
9
12
12
12
7
9
12
14
9
12
14
12
14
9
12
14
12
14
12
No. of Combos Rooms
AOTG30LBTA4 combinations
No. of Combos Rooms
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
2
3
BTU total Room 1 Room 2 Room 3 Room 4
31
33
36
38
36
42
28
32
38
28
30
34
40
31
33
37
43
35
39
45
43
49
27
30
7
9
12
14
18
18
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
9
9
24
24
24
24
18
24
7
7
7
9
9
9
9
12
12
12
12
14
14
14
18
18
9
9
14
18
24
12
14
18
24
12
14
18
24
14
18
24
18
24
9
12
-
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71 *1
72
73
74 *2
75
76
77
78
79
3
4
BTU total Room 1 Room 2 Room 3 Room 4
32
36
42
33
35
39
45
37
41
47
45
36
38
42
48
40
44
48
28
30
33
35
39
32
35
37
41
38
40
44
42
34
37
39
43
40
42
46
44
46
43
45
47
36
39
41
45
42
44
48
46
45
47
49
48
9
9
9
9
9
9
9
9
9
9
9
12
12
12
12
12
12
12
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
9
9
9
9
9
9
9
9
9
9
9
12
9
9
9
12
12
12
12
14
14
14
18
12
12
12
12
14
14
18
7
7
7
7
7
7
7
7
7
7
7
7
7
9
9
9
9
9
9
9
9
9
12
12
12
9
9
9
9
9
9
9
9
12
12
12
12
14
18
24
12
14
18
24
14
18
24
18
12
14
18
24
14
18
18
7
7
7
7
7
9
9
9
9
12
12
12
14
9
9
9
9
12
12
12
14
12
12
12
14
9
9
9
9
12
12
12
14
12
12
14
12
7
9
12
14
18
9
12
14
18
12
14
18
14
9
12
14
18
12
14
18
14
18
12
14
14
9
12
14
18
12
14
18
14
12
14
14
12
KEY
7
9
12
14
18
24
=
=
=
=
=
=
7,000
9,000
12,000
14,000
18,000
24,000
BTU / hr model
BTU / hr model
BTU / hr model
BTU / hr model
BTU / hr model
BTU / hr model
Installation precautions
AOTG24LAT3
Connectable capacity range:
14,000 - 36,000 BTU
At least two indoor units must be connected
ASTG24LFC✴
Cannot be connected to AOTG24LAT3
outdoor model
AOTG30LBTA4
Connectable capacity range:
27,000 - 49,000 BTU
At least three indoor units totalling
32,000 BTUs must be connected
These tables represent the only
allowable indoor unit combinations for
the Multi outdoor models
AOTG24LAT3 and AOTG30LBTA4.
No other combinations are
permissable. Correct operation
cannot be guaranteed if connected as
a configuration not shown on these
tables
Like the J Series product, the multi is
a technically advanced heat pump
system and because of this we
strongly recommend that your
specialist consults the technical
manual for actual output capacities of
varying combinations and ambient
conditions
Combinations that are not permissable
*1 ARTG09L + ARTG09L + ARTG09L +
ARTG18L
*2 ARTG09L + ARTG09L + ARTG12L +
ARTG18L
Explanation of features
Moisture Removal
The computer effectively dehumidifies the air.
Up/Down Swing Louvers
The up/down louvers automatically
swing to up and down.
Right/Left Swing Louvers
The right/left louvers automatically
swing in either direction.
Double Swing Automatic
Complex swing action of louvers enables
automatically to swing both horizontal and
vertical directions.
Automatic Louvers
The position of the louvers is set automatically
to match the operating mode. It is also possible
to adjust the flaps using the remote control.
Auto Shut Louvers
The auto shut louvers close or open
automatically when the unit stops or starts.
Automatic Air Flow Adjustment
The micro-computer automatically adjusts the
air flow effectively to follow the changes of
room temperature.
Auto restart
In the event of a temporary power failure,
the heat pump will automatically restart in
the same operating mode as before, once
the power supply is restored.
Auto-Changeover
When selected, the unit automatically
switches between heating and cooling
modes based on your temperature setting
and the room temperature.
Sleep Timer
The micro-computer gradually changes the
room temperature automatically to afford a
comfortable night’s sleep.
Program Timer
This digital timer allows selection of one of
four options.
ON, OFF, ON ––> OFF, or OFF ––> ON.
ON-OFF Timer
ON-OFF timer can be set to operate once.
Weekly timer
Different on-off times can be
set for each day.
Weekly + setback timer
Weekly + setback timer can set temperature
for two time spans and for each day of
the week.
Connectable Fresh Air Duct
Duct connection port hole opening. Fresh air
can be introduced through this opening.
Fresh air intake
Fresh air can be taken in by a fan which
can be connected using UTD-ECS5A
(optional parts).
Washable Panel
Control Port
External inputs and outputs contained within
the product allow on/off control, fresh air
interlock connection and heater bank element
connection.
Long-Life Ion Deodorisation Filter
Apple-Catechin Filter
Wall (wired) controller - Optional
Smart, easy-to-use wall (wired) controller.
7-day timer for ‘set and forget.
Cobalt Blue Heat Exchanger
Outdoor unit fins are coated with a blue
corrosion resistant material to enhance
durability and extend performance life of
your heat pump.
The ENERGY STAR® is awarded to the top
25% of New Zealand’s most efficient
appliances. Fujitsu has more ENERGY STAR®
heat pumps than any other brand
Cooling
Heating
SEPTEMBER2014
OUTDOOR UNITS
Inverter Multi Room Systems specifications
Type
Model No. Outdoor Unit
Heating Capacities
Cooling Capacities
C.O.P Heat
E.E.R Cool
Heat
Cool
Heat
Cool
Running Current
Input Power
Outdoor Sound Pressure Level
Dimensions
and Weights
Height
Width
Depth
Net Weight
Cool
Heat
O.U
Outdoor Operating Temperature
Inverter
AOTG24LAT3*1
8.0 (9.2 Max)
6.8 (8.5 Max)
4.0
3.5
8.4 (12.5 Max)
8.1 (12.5 Max)
2.0 (2.87 Max)
1.94 (2.6 Max)
49
700
900
330
55
0 to 46
-15 to 24
Outdoor Unit
kW
kW
W/W
W/W
Amps
Amps
kW
kW
Dba at 1m
mm
mm
mm
kg
Degree C
Degree C
PREMIER PLUS
Type
Model No.
Capacity Class
Fan Speeds
Air Circulation
Indoor Unit
kW
Indoor Sound
Pressure Level
Dimensions
and Weights
I.U
High
Quiet
Low
Medium
High
Height
Width
Depth
Net Weight
l/s
Dba at 1m
Dba at 1m
Dba at 1m
Dba at 1m
mm
mm
mm
kg
Inverter
AOTG30LBTA4*2
9.6 (12.0 Max)
8.0 (10.1 Max)
4.0
3.6
10.1 (15.7 Max)
9.3 (15.7 Max)
2.4 (3.58 Max)
2.22 (3.56 Max)
51
830
900
330
68
0 to 46
-10 to 24
PREMIER COMPACT
Model No.
Capacity Class
Fan Speeds
Air Circulation
Indoor Unit
kW
Indoor Sound
Pressure Level
Dimensions
and Weights
I.U
High
Quiet
Low
l/s
Dba at 1m
Dba at 1m
Medium
High
Height
Width
Depth
Net Weight
Dba at 1m
Dba at 1m
mm
mm
mm
kg
FLOOR / CEILING
INDOOR UNIT
PREMIER
HI WALL
HI WALL
HI WALL
HI WALL
HI WALL
HI WALL
HI WALL
ASTG09LUCB [M] ASTG14LUCB [M] ASTG07LVCA [M] ASTG09LVCC [M] ASTG12LVCC [M] ASTG18LFC✴ [M] ASTG24LFC✴ [M]
2.5
4.0
2.0
2.5
3.5
5.0
7.0
4
4
4
4
4
4
4
167
197
178
178
194
250
311
21
25
22
23
24
25
33
28
33
32
32
33
33
37
32
36
33
33
35
37
42
36
41
36
36
38
42
48
282
293
320
870
790
998
185
225
238
9.5
9.5
14
BULKHEAD INDOOR UNITS
Type
*1: Specifications of the AOTG24LAT3 are derived from the
standard combination = AOTG24LAT3 + ASTG07LVCA +
ASTG07LVCA + ASTG09LVCC
*2: Specifications of the AOTG30LBTA4 are derived from the
standard combination = AOTG30LBTA4 + ASTG09LVCC +
ASTG09LVCC + ASTG09LVCC + ASTG09LVCC
5.0
4
217
32 UC/35 FC
34 UC/37 FC
38 UC/41 FC
41 UC/44 FC
199
990
655
27
COMPACT CASSETTE INDOOR UNITS
BULKHEAD
ARTG09LLTA [M]
BULKHEAD
ARTG12LLTA [M]
BULKHEAD
ARTG18LLTA [M]
CASSETTE
AUTG09LVLA [M]
CASSETTE
AUTG12LVLA [M]
CASSETTE
AUTG18LVLA [M]
2.5
4
167
24
25
26
28
3.5
4
181
24
27
28
29
5.0
4
261
29
31
32
33
198
900
620
23
2.5
4
150
27
29
32
34
3.5
4
169
28
31
33
37
245
570
570
15
5.0
4
208
30
37
40
44
198
700
620
19
UNIVERSAL
ABTG18LVTA [M]
UC = Under Ceiling
FC = Floor Console
Explanation of terms
Capacity: The higher the capacity, the more area and faster
the heat pump will heat (and cool) the room.
COP: Stands for “Coefficient of Performance”, or (more simply!)
- the relationship of energy used and heat delivered. For example
– a COP of 3.61 means you will get 3.61kW of heat for every
1kW of energy used.
EER: Standsfor“EnergyEfficiencyRatio”,or(moresimply!)-the
relationshipofenergyusedandcoolingeffectdelivered.
Products depicted in this brochure contain high operating
pressure R410a refrigerant. It is illegal to vent that refrigerant
to the atmosphere. Only persons qualified and experienced
in the installation, service and repair of these products are
authorised to undertake such work.
Fujitsu General Accredited Installers have shown they have
the necessary equipment and have accepted responsibility
for their installations and the requirements of any statutes or
laws.
ENERGY STAR® Rating: Your quick guide to energy
efficiency – more stars means more efficient.
Due to ongoing Research and Development specifications
and designs are subject to improvement without notice
therefore relevant manuals must be consulted before any
action is taken to install or service these products.
Indoor Sound: Measured in decibels, this is the sound level
of your indoor unit at selected fan speeds. For example
20-30 decibels is less than the sound of a human whisper.
Heating/Cooling capacities and run current tests are based
on the requirements of AS/NZS3823, that standard tests at
the temperature (see right column).
Heating Range: With our Kiwi winter, your heat pump
needs to be able to supply heat indoors, even when its
-15˚C outside!
COOLING:
Indoor Temp: 27°C DB / 19°C WB
Outdoor Temp: 35°C DB
HEATING:
Indoor Temp: 20°C DB
Outdoor Temp: 7°C DB / 6°C WB
As actual temperature ranges in New Zealand vary
considerably only competent people should provide advice
as to size and placement of units.
Fujitsu General New Zealand Ltd warrants the equipment
against any defects in materials and factory workmanship for
a period of five years from the date of installation, or for 6
years if installed by an Accredited Installer.
This warranty does not cover defects or failures which are
attributable to; incorrect or improper installation;
environmental damage; airflow restriction; inadequate
electrical supply; getting access to the product.
FujitsuGeneralNewZealandLimited
www.fujitsugeneral.co.nz
Only Fujitsu heat pumps
are recommended by
Asthma New Zealand
Printed with 100% vegetable based inks. Printed on environmentally responsible paper.
NE W ZE
AL
AN
2014
014
2012
2
012
Independently awarded as
NZ’s leading iconic and trusted
heat pump brand.
The Home Comfort Specialist
FG1721_SEPT_2014
ACCREDITED
CONSULTANT
DED
AR
W
D
A
Why Fujitsu?
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising