Operational Manual for ID Lock 101 with Z-Wave - cd

Operational Manual for ID Lock 101 with Z-Wave - cd
M o nter ing sve
iv ise for
r
Operational
Manual
ID 1Lock
101
01-se
r iewith
n
Z-Wave Module 01A
V5.0 NO · 02.03.2015
Operational Manual - Z-wave module board 01A For ID Lock -101 series Doorlocks
v1.0 English released - 09.06.2016
Getting started…
IMPORTANT: Batteries must be removed prior to removing or
inserting the interface module.
Inclusion – (Puts your controller in inclusion mode)

Push and hold
button until all LEDs on keypad
activates. (with ID Lock in an unlocked state)

Release
button and press “8” on keypad.
Inclusion mode starts immediately. LED indicator below
logo signals this by flashing blue.
Exclusion – (Puts your controller in exclusion mode)

Push and hold
button until all LEDs on keypad
activates. (with ID Lock in an unlocked state)

Release
button and press “8” on keypad.
Exclusion mode starts immediately. LED indicator below
logo signals this by flashing blue.
Note: RF interface module can also be reset to factory default
settings from host software, by exclusion mode.
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
SUPPORTED COMMAND CLASSES
Non Secure mode
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CONFIGURATION_V1
5E
72
98
5A
80
73
70
Secure Mode
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_DOOR_LOCK_V2
COMMAND_CLASS_USER_CODE_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V1
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
86
62
63
85
59
71
7A
Configuration Parameter
This configuration parameter number and values are specific for application.
COMMAND_CLASS_CONFIGURATION
Name
Configuration
Set parameter
Parameter
Number
Size
1
1
Door Lock Mode
2
1
RFID Registration Mode
3
1
Door Hinge Position Mode
4~9
Description
Reserved ( For later use )
Door Lock Mode
Autolock Mode, Manuallock mode, Activate Away Mode, Deactivate Away Mode

Default Value : 1 ( Disable Away / Auto Lock Mode )
Name
Door Lock
Mode
Parameter
Number
Size
Value
1
1
0
Disable Away
Manual Lock
1
1
1
Disable Away
Auto Lock
1
1
2
Enable Away
Manual Lock
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
Description
1
1
3
Enable Away
Auto Lock
RFID Registration Configuration
IDLocks can use up to 50 RFID cards. In order to use a RFID, RFID has to be registered by z -wave
configuration command class.


Configuration Set in case of starting to register from backend side ( Ex. App)
Name
Parameter
Number
Size
Value
RFID Register
2
1
0x01
Begin RFID Registering mode on
the door lock
2
1
0x07
RFID Database clear
2
1
0x08
RFID Registering mode stop
Description
Configuration Report regarding Configuration Set
According to the process of registration RFID, these configuration reports are transmitted to the
gateway.
Name
Parameter
Number
Size
Value1
Value2
RFID Register
Mode
2
1
0x02
-
Fail
Registration new RFID was fail
Success
Registration new RFID was
Successful
RFID Index : 10 ~ 59
2
2
0x03
RFID
Index
Number
2
1
0x04
-
Finished
Registration mode finished and
end
2
1
0x05
-
Not In Progress
RFID Registration mode not in
progress
2
1
0x06
-
In Progress
RFID Registration mode in progress
Retrieve RFID Information

Description
Configuration Get for retriving the RFID information
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
Parameter
Number
Name
Get RFID
Infomation

10 ~ 59
Description
RFID Information registered
Parameter Number means RFID index.
10 = RFID index 1
....
59 = RFID index 50
Configuration Report for retriving the RFID information
For example : RFID index is 1 and information is 0xFDBEC2DE
Name
Get RFID
Infomation
Parameter
Number
Size
10
4
Para1
0xFD
Para2
Para3
Para4
0xBE
0xC2
0xD2
Notification Parameter
This Notification parameter ( types an levels) are specific for application.
The IDLock supports the Notification Class(V4) to report events of IDLock.
The type and event are specific for IDLock and defines are as below.
COMMAND_CLASS_NOTIFICATION(V4)
Notification Type
Access Control
(0x06)
Event
Event
Parameter
Description
Manual Lock Operation
(0x01)
Manual Unlock Operation (0x02)
Home Security(0x07)
RF Unlock Operation
(0x04)
RFID Index Info.
Unlock by RFID
Keypad UnLock Operation
(0x06)
User ID of User
Code Report
User ID = 1 (Master
PIN)
User ID =2 ( Service
PIN)
User ID =0 ( Remote
Unlock)
Unlock By RF with invalid user
code (0x14)
Unknown
Credential
Infomation
Unknown PIN Code
Or
Unknown RFID
Tampering,
Product covering Removed
(0x03)
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
Door Forced Open
Emergency (0x0A)
Contact Fire Service (0x2)
Fire Sensor
Use Case of Manual Lock Notification

Example : Lock the door by Maual or RFID / Keypad
Notification
Type
Notification
Event
Para
Length
0x06
0x01
0
Use Case of Manual Unlock Notification

Example : Unlock the door by thumbturn switch or open/close button
Notification
Type
Notification
Event
Para
Length
0x06
0x02
0
Use case of RF Unlock Operation

Example : Unlock the door by RFID Card ( Ex. RFID Index is 10 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x04
0x01
0x0A
Use case of Keypad Unlock Operation

Example : Unlock the door by Keypad using PIN Code
The vaule of para1 means User ID of Master PIN ( User ID = 1 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x06
0x01
0x01
The vaule of para1 means User ID of Service PIN ( User ID = 2 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x06
0x01
0x02
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
If the door is unlocked by remote side from mobile Application, in order to know the status, the
value of para1 means remote User ID ( application specific value = 0 )
Notification
Type
Notification
Event
Para
Length
Para1
0x06
0x06
0x01
0x00
Use case of Unlock by RF with invalid user code

Example : Invalid PIN code Notification Report
PIN Type is 1 value and Invalid PIN code is 785469

Notification
Type
Notification
Event
Para
Length
Para1
Para2
Para3
Para4
0x06
0x14
4
0x01
0x78
0x54
0x69
Example : Invalid PIN code Notification Report
RFID Type is 2 value and Invalid RFID is 0x89AE939C
Notification
Type
Notification
Event
Para
Length
Para1
Para2
Para3
Para4
Para4
0x06
0x14
5
0x02
0x89
0xAE
0x93
0x9C
Use case of Tampering ( Door Forced Open)

Example : When the door is opened forcely (Alarm )
Notification
Type
Notification
Event
Para
Length
0x07
0x03
0x00
Use case of Emergency( Fire Sensor )

Example : The fire is detected by fire sensor of door lock
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
Notification
Type
Notification
Event
Para
Length
0x0A
0x02
0x00
Manufacture Parameter
The IDLock supports the Manufacture Specific Command Class with following parameters.
COMMAND_CLASS_MANUFACTURE_SPECIFIC_V2
Name
Value
Description
Manufacture ID
0x0230
Product Type ID
0x03
PRODUCT_TYPE_ID_ZWAVE_PLUS
Product ID
0x01
PRODUCT_ID_DoorLockKeyPad
Version Parameter
The IDLock supports the Door Lock Command Class Version 2 with following parameters.
COMMAND_CLASS_VERSION_V2
Name
Value
Z-wave Protocol Library Type
0x03
Z-wave Protocol Version
0x04
Z-wave Protocol Sub version
0x05
Firmware 0 Version
0x01
Firmware 0 Sub Version
0x00
Hardware Vesion
0x01
Association & Association Group Parameter
The IDLock supports 1 association group with 5 devices.
Notification Reports are sent out unsolicated to device included in the association group.
○ Grouping identifier : 1
○ Name : Lifeline
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
User Code Parameter
The IDLock have 2 pin codes(Master PIN and Service PIN ) that are 4 -10 digit in lengh.
○ Master PIN : User Identifier 1
○ Service PIN: User Identifier 2
ID Lock AS – Stasjonsveien 46, 4460 Moi, Norway
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF