LA090HYV
Art Cool™ Premier Single Zone Inverter
Outdoor Unit (ODU) - LAU090HYV Indoor Unit (IDU) - LAN090HYV
Performance:
Cooling:
Operating Range:
Outdoor Unit:
Capacity (Btu/h)
SEER
EER
9,000
27.5
16.0
SEER - Seasonal Energy Efficiency Ratio EER - Energy Efficiency Ratio
Capacity (Btu/h)
HSPF
11,000
11.8
HSPF - Heating Seasonal Performance Factor
Heating Nominal Test Conditions:
Indoor: 70°F DB/60°F WB
Outdoor: 47°F DB/43°F WB
Electrical:
Power Supply (V¹/Hz/Ø)
208-230/60/1
Outdoor Unit:
15
MOP (A)
MCA (A)
Cooling Rated Amps (A)
11.2
8.70
Heating Rated Amps (A)
8.70
Compressor (A)
Fan Motor (A)
8.3
0.40
MOP - Maximum Overcurrent Protection MCA - Minimum Circuit Ampacity
Total Power Input:
Cooling Power Input (kW)
Heating Power Input (kW)
0.56
0.70
Piping:
Liquid Line (in, OD)
Vapor Line (in, OD)
Additional Refrigerant (oz/ft)
Max Pipe Length (ft)²
Piping Length (no add'l refrigerant, ft)
1/4
3/8
0.22
65.6
41.0
Max Elevation (ft)
32.8
Controls Features:
•24-Hour on/off mer
•4-Way auto swing
•Auto changeover
•Auto restart
•Built-in low ambient operation to 14°F
•Chaos wind
•Condensate sensor connection
•Defrost control
•Dehumidifying mode
•Hot start
•Jet cool/Jet heat
•Self cleaning indoor coil
14-118
-13-75
Indoor Unit:
Cooling (°F WB)
Heating (°F DB)
Heating:
Cooling Nominal Test Conditions:
Indoor: 80°F DB/67°F WB
Outdoor: 95°F DB/75°F WB
Cooling (°F DB)
Heating (°F WB)
64-90
60-86
Unit Data:
Refrigerant Type
Refrigerant Control
Refrigerant Charge (lbs)
ODU Sound Pressure (Max) ±3 dB(A)³
IDU Sound Pressure (H/M/L/Sleep) ±3 dB(A)³
R410A
EEV
2.54
45
42/36/25/17
ODU Net Unit Weight (lbs)
ODU Shipping Weight (lbs)
73
78
IDU Net Unit Weight (lbs)
25
IDU Shipping Weight (lbs)
Heat Exchanger Coating
29
GoldFin™
Fan:
ODU Type
IDU Type
Fan Speeds (Fan/Cooling/Heating)
Quantity (ODU + IDU)
Motor/Drive
Propeller
Cross Flow
6/6/6
1 + 1
Brushless Digitally Controlled/Direct
1,165
ODU Max Air Flow Rate (CFM)
IDU Air Flow H/M/L (CFM)
Dehumidification (pts/hr)
494/417/283
3.3
Notes:
1.Acceptable opera ng voltage: 187V - 253V.
2.Piping lengths are equivalent.
3.Sound Pressure levels are tested in an anechoic chamber under ISO Standard 1996.
4.All power/communica on cable to be minimum 18 AWG, 4-conductor, stranded, shielded and must comply with applicable local and national code.
5.See Engineering Manual for sensible and latent capaci es.
6.Power wiring cable size must comply with the applicable local and na onal code.
7.The indoor unit comes with a dry helium charge.
8.This data is rated 0 above sea level, with 24.6 of refrigerant line and a 0 level difference between outdoor and indoor units. 9.Must follow installa on instruc ons in the applicable LG installa on manual.
•Self diagnosis
•Sleep mode
•So dry opera on
•Ultra quiet opera on
•Cooling only switch
Optional Accessories (sold separately):
LG Programmable Thermostat - PREMTB10U
Dry Contact for third party thermostat - PQDSBNGCM1
For continual product development, LG reserves the right to change specifications without notice.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS-SB-AG-003-US 013J05
Page 1 of 3
Job Name/Location:
Outdoor Unit (ODU) - LAU090HYV
Tag #:
Art Cool™ Premier Single Zone Inverter
Date:
PO No.:
For continual product development, LG reserves the right to change specifications without notice.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS-SB-AG-003-US 013J05
Page 2 of 3
Job Name/Location:
Indoor Unit (IDU) ‐ LAN090HYV
Tag #:
Art Cool™ Premier Single Zone Inverter
Date:
PO No.:
For continual product development, LG reserves the right to change specifications without notice.
© LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. “LG Life’s Good” is a registered trademark of LG Corp. /www.lghvac.com
DFS‐SB‐AG‐003‐US 013J05
Page 3 of 3
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising