Professional portable
manufactured by
GPS Multiparameter Meter | HI-9829
+
DIN
connection
water
resistant
interchangeable
electrode
replaceable
electrode
battery
powered
mains
powered
Professional
portable
multiparameter meter
Ideal for detailed environmental monitoring, the
HI-9829 delivers acccurate, reliable and dependable
measurements to support research and investigation into
water quality, waste water, landfill and pollution.
Star features to support professional
measurement in the field
Logging from probe or meter
Fast Tracker Tag
Identification System
Excellent connectivity with
PC compatibility via USB
On-screen user guides
Auto-recognition of all
sensors
Backlit, graphic LCD display
GLP features to support
good laboratory practice
Waterproof casing
Which meter do I need?
Designed to support optimum customisation, the HI-9829
multiparameter meter is available in a range of options.
To choose, simply build up the configuration that suits your application best.
1. Meter: with or without GPS
for meter without GPS select Standard model
for meter with global positioning select GPS model
2. Digital probe: with or without logging
3. Sensor: with or without turbidity
for turbidity select combined EC/turbidity sensor
turbidity not required? select EC sensor option
4. Choice of three cable lengths:
4m, 10m, 20m cable length
Authorised distributor
manufactured by
GPS Multiparameter Meter | HI-9829
Rugged and waterproof
Rugged, waterproof and easy to use, the HI-9829 is the ideal meter for field
measurement in lakes, rivers and seas.
It displays 1 to 12 parameters simultaneously from up to 14 user selectable parameters.
GPS Capabilities
The HI-9829 is offered with or without GPS capabilities.
The meter with the GPS option incorporates a built-in GPS receiver and antenna to
guarantee an accurate position.
Measurements from specific locations are tracked with detailed coordinate information that
can be viewed immediately on the display and reviewed on Google ™ Maps* using a PC
*Google™ is a registered trademark of Google™inc. Hanna Instruments® has no affiliation with Google™
Choice of dedicated sensors to measure up to 14
water quality parameters:
Digital probes offer logging and non-logging options with a number of tailored
sensor configurations to measure up to 14 water quality parameters:
pH, ORP, conductivity, turbidity, temperature, ions ammonium, nitrate, chloride, dissolved
oxygen (as % saturation or concentration), resistivity, TDS, salinity, and seawater σ.
Atmospheric pressure is measured for DO concentration compensation.
Deta
ch
prob
e
and
leav
e it
logg
ing o
its ow n
n
Autonomously logging digital probes
The logging probe is available with or without a combined EC/turbidity sensor.
After starting a log, both versions will autonomously log parameters without further
connection to the meter. Once the log has begun, simply detach the probe and
leave it in situ. The probe will happily carry on logging until your selected sampling
period is complete - even though it is disconnected from the meter.
The logged measurements can be subsequently retrieved by connecting the
logging probe to the meter or a to PC.
User friendly features
The HI-9829 features a graphic, backlit LCD that scales digits to fit up to
12 parameters. It also allows full configuration of each parameter to be
measured along with an on-screen graphing capability.
The HELP key displays context sensitive help.
The alpha-numeric keypad offers a user friendly way to complete the input fields.
Authorised distributor
manufactured by
GPS Multiparameter Meter | HI-9829
dedicated digital probes & variable sensor configurations
Hanna probes for use with the HI-9829 are designed to offer you maximum opportunity to tailor the configuration to
meet your specific applications.
Make your choice easier by using these four quick steps
1
2
3
4
Logging or non-logging
Choice of sensor configuration
Cable length
ISE?
The HI-9829 can be used with logging
or non-logging probes.
Each logging or non-logging probe
is offered with a choice of sensor
configurations.
All meters are offered with a choice
of three cable lengths:
If you are looking to use ISE, select from
the following sensors as an extra option.
Depending on the sensor configuration,
both the logging and non-logging
probes are offered with a short or long
sensor shield cap.
Long cap: fits all configurations
Short cap: fits configurations
WITHOUT the turbidity/EC sensor
4 metres
10 metres
20 metres
ISE: Ammonium
code: HI-7609829-10
ISE: Chloride
code: HI-7609829-11
ISE: Nitrate
code: HI-7609829-12
high spec probes
Digital probes provide stable, noise-free sensor signal management without the need for further amplification.
Field-ready
Collect and save your data
Designed for use out on location HI-9829 probes
use field-replaceable sensors with auto-recognition.
They are also housed in a rugged casing with a
watertight cable connection.
The logging option allows probes to be connected
directly to a PC and to download log files directly from
the probes using Hanna software and USB cable.
Quick calibration
To calibrate in the field simply screw the calibration
beaker filled with solution onto the probe, select
‘quick calibration’ from the menu and press OK
Individual calibration can be performed using
multiple calibration points
Ready-prepared quick calibration solution
allows users to standardise pH and conductivity
with one calibration solution
What length of cable?
A choice of three cable lengths with options for 4m,
10m and 20m makes the meter a popular option for a
wide range of uses in tough conditions.
Authorised distributor
Probes with the logging function have a logging
memory with the capacity to store up to
140,000 individual samples or 35,000 complete
sample sets. Data includes a date and time
stamp to allow up to 70-day deployment with all
channels logging at 10 minute intervals.
14,000 individual samples
35,000 full sample sets
70-day deployment with
full channel logging every 10
minutes
manufactured by
GPS Multiparameter Meter | HI-9829
sensors to suit
Hanna offers a choice of eight types of sensor to be be used on the intelligent probes.
Replacement is quick and easy with screw
type connectors and colour coding for easy
identification
Sensors are automatically recognised as soon
as they are plugged in.
Combined EC/Turbidity sensor offers readings
from both parameters at the same time
All potentiometric sensors feature a double
junction design and are gel filled to increase
resistance to contamination
One of a choice of three ISE sensors can be
used in place of the pH sensor
ISE sensors include: ammonium ISE; chloride
ISE; nitrate ISE. Add these as an extra aption
to your order as required.
pH in mV readings are also displayed
– useful for troubleshooting
or
DO
pH/ORP
or
ISE
EC/TDS
EC/Turbidity
Short cap for probes without
EC/turbidity sensor
Long cap for probes with
EC/turbidity sensor
A choice of sensors
pH/ORP
Dissolved Oxygen
Combined EC/Turbidity
pH or pH/ORP sensors are gel filled and use a resilient PEI
body to protect them from solid particles.
The HI-9829 galvanic DO sensor does not require
long polarisation times which makes it ready for
measurement at a moment’s notice. It also uses a
replaceable cap design for ease of maintenance and a
safe non-toxic electrolyte.
The combined EC/turbidity sensor is a replaceable
design for instant conductivity and turbidity
measurements that conform to ISO7027 standards. It
provides measurement from 0.0 to 1000FNU.
Using the built-in temperature sensor, temperature
compensation is automatic from -5 to +55°C.
ISE
A choice of three ion selective electrodes (ISE) is
available for constant reporting of common surface
wtaer contaminants: nitrate, ammonium and chloride
ISE are available.
Each ISE electrode is a combination electrode
incorporating a constant reference spiral and features
a double junction and solid gel reference design. By
using conductivity, the HI-9829 converts the ion
activity measurement to concentration units and
displays these as ppm ammonium-nitrogen; ppm
chloride; and ppm nitrate-nitrogen.
Authorised distributor
DO readings are compensated for the effects of
temperature and atmospheric pressure using the built in
temperature and internal atmospheric pressure sensors.
Conductivity measurement is the same as for the
single EC sensor.
Order Information
EC/TDS
Sensor modules
The HI-7609829-3 four-electrode conductivity
sensor uses the polarographic measurement principle
to ensure stable conductivity readings.
pH
pH/ORP
ISE: Ammonium
ISE: Chloride
ISE: Nitrate
Dissolved Oxygen
EC/TDS
EC/Turbidity
Absolute
conductivity,
temperature-corrected
conductivity, salinity, seawater and water hardness
(TDS) determinations are all possible with
measurements from this sensor.
Price
Code
£00.00
£00.00
£00.00
£00.00
£00.00
£00.00
£00.00
£00.00
HI-7609829-0
HI-7609829-1
HI-7609829-10
HI-7609829-11
HI-7609829-12
HI-7609829-2
HI-7609829-3
HI-7609829-4
manufactured by
GPS Multiparameter Meter | HI-9829
more about GPS and tracking
Monitoring and tracking
All models of HI-9829 are equipped with the Fast Tracker TAG ID
system. This is invaluable for associating measurements with
their locations.
They also feature a real-time clock which stamps all logged data
with a time and date in addition to location information.
Fast tracker – TAG Identification System
Hanna Fast Tracker TAG system simplifies test logging using iButtons
with a unique ID which can be installed at different sampling sites.
When the matching connector on the meter contacts the location
button, measurements are logged and labeled with alphanumeric
user-entered location ID.
Location, date, time and measurements are logged into the meter
for transfer to PC.
Multiple iButton TAGs can be installed and additional TAGS can be
ordered for all your traceability requirements.
With GPS models, Fast Tracker TAG complements the GPS for ultimate
tracking.
Authorised distributor
manufactured by
GPS Multiparameter Meter | HI-9829
GPS for optimum positioning data
The HI-9829 with GPS can track measurement locations with detailed
coordinate information.
It features an internal 12 channel GPS receiver and antenna to
calculate its position to track locations and measurement data.
Location can be tracked to within 10m to ensure repeated
measurements can be taken at the same locations.
Coordinates are shown on the LCD together with up to 10
measurement parameters and are recorded with logged data.
View locations where samples have been taken by connecting to GPS
tracking software such as Google™ Maps* and see measurement
information right on the map.
*Google ™ is a registered trademark of Google™inc. Hanna Instruments® has no affiliation
with Google™ Basic GPS + advanced features
HI-9829 with GPS comes complete with a basic set of benefits together with
a set of advanced features.
Basic GPS features
GPS coordinates shown on LCD with up to 10 measurement parameters
GPS signal strength shown on LCD
Logged data is embedded with GPS coordinates
GPS status screen
Advanced GPS features
Users can associate GPS coordinates with alphanumeric locations
Distances between current location and predefined locations are displayed –
arranged by distance
Memorises last location and time in case signal is lost
Application software
Completing the package, dedicated Hanna software:
Authorised distributor
Manages logged data
Displays GPS coordinates with logged data
Automatically maps samples on PC via internet connection
Shows location points on map with measurement data
manufactured by
GPS Multiparameter Meter | HI-9829
specifications for HI-9829
auto
no
logg mous
ing
with
o
logg ut
ing
HI-7629829
for pH/ORP, Dissolved
Oxygen, EC, Logging
HI-7609829
for pH/ORP, Dissolved
Oxygen, EC
Probe
HI-7609829 / HI-7619829**
without logging
Temperature
Compensation
HI-7629829 / HI-7639829**
autonomous logging
Connector 1
pH, pH/ORP, ammonium ISE, chloride ISE, nitrate ISE
pH, pH/ORP, ammonium ISE, chloride ISE, nitrate ISE
Connector 2
dissolved oxygen
dissolved oxygen
Connector 3
Upgradeable
EC
EC
to HI-7619829, adding EC/turbidity sensor and long protective shield
to HI-7639829, adding EC/turbidity sensor and long protective shield
Temperature sensor
built-in
built-in
Autonomous Logging
—
yes
Logging Interval
—
1 second to 3 hours
Computer Inteface
—
USB (HI-76982910)
Memory
—
140,000 measurements (single parameter logged);
35,000 measurements (all parameters logged)
Operating Temperature
-5 to 55°C*
20 m*
Maximum Depth
20 m*
20 m*
Cable Specification
Multistrand-multiconductor shielded cable with internal strength member rated for 68 kg (150 lb.) intermittent use
Wetted Materials
Body: ABS; Threads: nylon; Shield: ABS/316 SS; Temperature Probe: 316 SS; O-rings: EPDM
Logging Probe Internal Battery Type
Logging Probe Battery Life
Note: Log space must be available for
continuous logging
Sample Environment
—
1.5V (4) AA alkaline
—
Interval
All channels logging (no averaging)
—
1-5 seconds
72 hours
—
1 minute
22 days
—
10 minutes
70 days
fresh, brackish, seawater
fresh, brackish, seawater
Waterproof Protection
IP68
IP68
Dimensions (without cable)
342 mm, dia=46 mm
442 mm, dia 46 mm
Weight (with batteries and sensors)
570 g
775 g
* Reduced for ISE sensors
** NOTE
Authorised distributor
for Turbidity without logging select probe HI-7619829
for Turbidity with autonomous logging select probe HI-7639829
manufactured by
GPS Multiparameter Meter | HI-9829
HI-9829 GPS Multiparameter Meter
HI-9829
HI-9829 with GPS
Temperature Compensation
automatic from -5 to 55°C
automatic from -5 to 55°C
GPS
—
12 channel receiver, 10 m (30 ft) range
Logging Memory from Meter
44,000 records
44,000 records
Logging Interval
1 second to 3 hours
1 second to 3 hours
Computer Interface
USB (with HI-929829 software)
USB (with HI-929829 software)
FastTracker™ TAG ID
Yes
Yes
Waterproof Protection
IP67
IP67
Environment
0 to 50°C; RH 100%
0 to 50°C; RH 100%
Power Supply
1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4), USB, 12V power adapter
1.5V alkaline C cells (4) / 1.2V NiMH rechargeable C cells (4), USB, 12V power adapter
Dimensions / Weight
221 x 115 x 55 mm / 750g
221 x 115 x 55 mm / 750g
HI-9829 Parameters
Range
Resolution
Accuracy @ 20°C
Calibration
pH/mV of pH input
0.00 to 14.00 pH / ±600.0 mV
0.01 pH / 0.1 mV
±0.02 pH / ±0.5 mV
automatic one, two, or three points with five memorized
standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one
custom buffer
ORP mV
±2000.0 mV
0.1 mV
±1.0 mV
automatic at one custom point
Ammonium-Nitrogen
0.02 to 200 ppm (as N)
0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
±5% of reading or 2 ppm,
whichever is greater
automatic at one custom point
Chloride
0.6 to 200 ppm
0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
±5% of reading or 2 ppm,
whichever is greater
1 or 2 point, 10 ppm and 100 ppm
Nitrate-Nitrogen
0.62 to 200 ppm (as N)
0.01 ppm to 1 ppm; 0.1 ppm to 200 ppm
±5% of reading or 2 ppm,
whichever is greater
1 or 2 point, 10 ppm and 100 ppm
0 to 200 mS/cm
(absolute EC up to 400 mS/cm)
manual:
1 μS/cm; 0.001 mS/cm; 0.01 mS/cm;
0.1 mS/cm; 1 mS/cm;
automatic:
1 μS/cm from 0 to 9999 μS/cm;
0.01 mS/cm from 10.00 to 99.99 mS/cm;
0.1 mS/cm from 100.0 to 400.0 mS/cm;
automatic mS/cm:
0.001 mS/cm from 0.000 to 9.999 mS/cm;
0.01 mS/cm from 10.00 to 99.99 mS/cm;
0.1 mS/cm from 100.0 to 400.0 mS/cm
±1% of reading or ±1 μS/cm,
whichever is greater
automatic one point with six memorized standards
(84 μS/cm, 1413 μS/cm, 5.00 mS/cm, 12.88 mS/cm,
80.0 mS/cm, 111.8 mS/cm) or custom point
TDS
0 to 400000 mg/L or ppm
(the maximum value depends
on the TDS factor)
manual:
1 mg/L (ppm); 0.001 g/L (ppt);
0.01g/L (ppt); 0.1 g/L (ppt); 1 g/L (ppt);
automatic:
1 mg/L (ppm) from 0 to 9999 mg/L (ppm);
0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt);
0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt);
autorange g/L (ppt) scales:
0.001 g/L (ppt) from 0.000 to 9.999 g/L (ppt);
0.01 g/L (ppt) from 10.00 to 99.99 g/L (ppt);
0.1 g/L (ppt) from 100.0 to 400.0 g/L (ppt)
±1% of reading or ±1 mg/L,
whichever is greater
based on conductivity or salinity calibration
Resistivity
0 to 999999 Ω•cm;
0 to 1000.0 kΩ•cm;
0 to 1.0000 MΩ•cm
dependent on
resistivity reading
—
—
Salinity
0.00 to 70.00 PSU
0.01 PSU
±2% of reading or ±0.01 PSU,
whichever is greater
one custom point
Seawater σ
0 to 50.0 σt,σ0, σ15
0.1 σt, σ0, σ15
±1 σt, σ0, σ15
based on conductivity or salinity calibration
Turbidity
0.0 to 99.9 FNU;
100 to 1000 FNU
0.1 FNU from 0.0 to 99.9 FNU;
1 FNU from 100 to 1000 FNU
±0.3 FNU or ±2% of reading,
whichever is greater
Automatic 1, 2 or 3 points at 0, 20 and 200 FNU, or custom
automatic one or two points at 0, 100%
or one custom point
Conductivity
Dissolved Oxygen
0.0 to 500.0%;
0.00 to 50.00 ppm
0.1%; 0.01 ppm
0.0 to 300.0%: ±1.5% of
reading or ±1.0% whichever
is greater; 300.0 to 500.0%:
±3% of reading; 0.00 to
30.00 ppm: ±1.5% of reading
or 0.10 ppm, whichever is
greater; 30.00 ppm to
50.00 ppm: ±3% of reading
Atm. Pressure
450 to 850 mm Hg;
17.72 to 33.46 in Hg;
600.0 to 1133.2 mbar;
8.702 to 16.436 psi;
0.5921 to 1.1184 atm;
60.00 to 113.32 kPa
0.1 mm Hg; 0.01 in Hg; 0.1 mbar;
0.001 psi; 0.0001 atm; 0.01 kPa
±3 mm Hg within ±15°C
from the temperature
during calibration
automatic at one custom point
Temperature
-5.00 to 55.00°C;
23.00 to 131.00°F;
268.15 to 328.15K
0.01°C; 0.01°F; 0.01K
±0.15°C; ±0.27°F; ±0.15K
Automatic at one custom point
Authorised distributor
manufactured by
GPS Multiparameter Meter | HI-9829
Order Info
Standard
No Logging
No Turbidity
GPS
No Logging
No Turbidity
Standard
No Logging
+ Turbidity
GPS
No Logging
+ Turbidity
Code
Supplied with
HI-9829-00042
4m cable
HI-9829 meter, HI-7609829/4 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs), HI-929829
PC application software, HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-710045 power
supply cable, HI-7698292 probe maintenance kit, HI-7698290 short calibration beaker, HI-9828-25 calibration solution (500 mL),
HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-00102
10m cable
HI-9829 meter, HI-7609829/10 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs), HI-929829
PC application software, HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-710045 power
supply cable, HI-7698292 probe maintenance kit, HI-7698290 short calibration beaker, HI-9828-25 calibration solution (500 mL),
HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-00202
20m cable
HI-9829 meter, HI-7609829/20 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs), HI-929829
PC application software, HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-710045 power
supply cable, HI-7698292 probe maintenance kit, HI-7698290 short calibration beaker, HI-9828-25 calibration solution (500 mL),
HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-10042
4m cable
HI-9829 meter with GPS, HI-7609829/4 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs),
HI-929829 PC application software, HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-710045
power supply cable, HI-7698292 probe maintenance kit, HI-7698290 short calibration beaker, HI-9828-25 calibration solution
(500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-10102
10m cable
HI-9829 meter with GPS, HI-7609829/10 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs),
HI-929829 PC application software, HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-710045
power supply cable, HI-7698292 probe maintenance kit, HI-7698290 short calibration beaker, HI-9828-25 calibration solution
(500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-10202
20m cable
HI-9829 meter with GPS, HI-7609829/20 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs),
HI-929829 PC application software, HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-710045
power supply cable, HI-7698292 probe maintenance kit, HI-7698290 short calibration beaker, HI-9828-25 calibration solution
(500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-01042
4m cable
HI-9829 meter, HI-7619829/4 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs), HI-929829
PC application software, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4 EC/Turbidity sensor, HI-710045
power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL), HI-9829-17 20 FNU
calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker, HI-9828-25
calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-01102
10m cable
HI-9829 meter, HI-7619829/10 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs), HI-929829
PC application software, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4 EC/Turbidity sensor, HI-710045
power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL), HI-9829-17 20 FNU
calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker, HI-9828-25
calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-01202
20m cable
HI-9829 meter, HI-7619829/20 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs), HI-929829
PC application software, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4 EC/Turbidity sensor, HI-710045
power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL), HI-9829-17 20 FNU
calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker, HI-9828-25
calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-11042
4m cable
HI-9829 meter with GPS, HI-7619829/4 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs),
HI-929829 PC application software, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4 EC/Turbidity sensor,
HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL), HI-9829-17
20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker,
HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-11102
10m cable
HI-9829 meter with GPS, HI-7619829/10 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs),
HI929829 PC application software, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4 EC/Turbidity sensor,
HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL), HI-9829-17
20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker,
HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
HI-9829-11202
20m cable
HI-9829 meter with GPS, HI-7619829/20 probe, HI-7698291 USB cable (PC to meter), HI-920005 iButton® with holder (5 pcs),
HI-929829 PC application software, HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4 EC/Turbidity sensor,
HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL), HI-9829-17
20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker,
HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual.
All ISE sensors supplied as extra:
Authorised distributor
ISE Ammonium: code: HI-7609829-10;
ISE Chloride: code: HI-7609829-11;
ISE Nitrate: code: HI-7609829-12
manufactured by
GPS Multiparameter Meter | HI-9829
Order Info
Standard
+ Autonomously
Logging Probe
No Turbidity
GPS
+ Autonomously
Logging Probe
No Turbidity
Standard
+ Autonomously
Logging Probe
+ Turbidity
GPS
+ Autonomously
Logging Probe
+ Turbidity
Code
Supplied with
HI-9829-02042
4m cable
HI-9829 meter, HI-7629829/4 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1
pH/ORP sensor, HI-710045 power supply cable, HI-7698290 short calibration beaker, HI-9828-25 calibration solution (500 mL),
HI-710006/8 (230V), instruction manual
HI-9829-02102
10m cable
HI-9829 meter, HI-7629829/10 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1
pH/ORP sensor, HI-710045 power supply cable, HI-7698290 short calibration beaker, HI-9828-25 calibration solution (500 mL),
HI-710006/8 (230V), instruction manual
HI-9829-02202
20m cable
HI-9829 meter, HI-7629829/20 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-3 EC sensor, HI-7609829-2 DO sensor, HI-7609829-1
pH/ORP sensor, HI-710045 power supply cable, HI-7698290 short calibration beaker, HI-9828-25 calibration solution (500 mL),
HI-710006/8 (230V), instruction manual
HI-9829-12042
4m cable
HI-9829 meter with GPS, HI-7629829/4 probe, HI-76982910 USB cable, (PC to Probe), HI-7698291 USB cable (PC to meter),
HI-929829 PC application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-3 EC sensor, HI-7609829-2 DO sensor,
HI-7609829-1 pH/ORP sensor, HI-710045 power supply cable, HI-7698290 short calibration beaker, HI-9828-25 calibration
solution (500 mL), HI-710006/8 (230V), instruction manual
HI-9829-12102
10m cable
HI-9829 meter with GPS, HI-7629829/10 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter),
HI-929829 PC application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-3 EC sensor, HI-7609829-2 DO sensor,
HI-7609829-1 pH/ORP sensor, HI-710045 power supply cable, HI-7698290 short calibration beaker, HI-9828-25 calibration
solution (500 mL), HI-710006/8 (230V), instruction manual
HI-9829-12202
20m cable
HI-9829 meter with GPS, HI-7629829/20 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter),
HI-929829 PC application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-3 EC sensor, HI-7609829-2 DO sensor,
HI-7609829-1 pH/ORP sensor, HI-710045 power supply cable, HI-7698290 short calibration beaker, HI-9828-25 calibration
solution (500 mL), HI-710006/8 (230V), instruction manual
HI-9829-03042
4m cable
HI-9829 meter, HI-7639829/4 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4
EC/Turbidity sensor, HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution
(230 mL), HI-9829-17 20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long
calibration beaker, HI9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual
HI-9829-03102
10m cable
HI-9829 meter, HI-7639829/10 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4
EC/Turbidity sensor, HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution
(230 mL), HI-9829-17 20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long
calibration beaker, HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual
HI-9829-03202
20m cable
HI-9829 meter, HI-7639829/20 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4
EC/Turbidity sensor, HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL),
HI-9829-17 20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker,
HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/98 (230V), instruction manual
HI-9829-13042
4m cable
HI-9829 meter with GPS, HI-7639829/4 probe,HI-76982910 USB cable, (PC to Probe), HI-7698291 USB cable (PC to meter),
HI-929829 PC application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor,
HI-7609829-4 EC/Turbidity sensor, HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration
solution (230 mL), HI-9829-17 20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293
long calibration beaker, HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction
manual
HI-9829-13102
10m cable
HI-9829 meter with GPS, HI-7639829/10 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter), HI-929829 PC
application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP sensor, HI-7609829-4
EC/Turbidity sensor, HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU calibration solution (230 mL),
HI-9829-17 20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL), HI-7698293 long calibration beaker,
HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8 (230V), instruction manual
HI-9829-13202
20m cable
HI-9829 meter with GPS, HI-7639829/20 probe, HI-76982910 USB cable (PC to Probe), HI-7698291 USB cable (PC to meter),
HI-929829 PC application software, HI-920005 iButton® with holder (5 pcs), HI-7609829-2 DO sensor, HI-7609829-1 pH/ORP
sensor, HI-7609829-4 EC/Turbidity sensor, HI-710045 power supply cable, HI-7698292 probe maintenance kit, HI-9829-16 0 FNU
calibration solution (230 mL), HI-9829-17 20 FNU calibration solution (230 mL), HI-9829-18 200 FNU calibration solution (230 mL),
HI-7698293 long calibration beaker, HI-9828-25 calibration solution (500 mL), HI-710046 cigarette lighter cable, HI-710006/8
(230V), instruction manual
Authorised distributor
Wolf Laboratories Limited
www.wolflabs.co.uk
Tel: 01759 301142
Fax:01759 301143
sales@wolflabs.co.uk
Use the above details to contact us if this literature doesn't answer all your
questions.
Pricing on any accessories shown can be found by keying the part number
into the search box on our website.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising