CR17335
CR17335: 2/3A Size Spiral Cell
Technical Datasheet
Technical Specifications
Features
• High and stable operating voltage
• Higher power and higher energy for the
whole battery life
• Superior drain capability
• Higher power applications
• Low self-discharge rate (less than 2% after
1 year of storage at +20°C)
• Battery life higher than 10 years,
depending on the application
• Hermetic glass-to-metal sealing
• Avoid leakage, key for a higher than
10 year battery life
• PTC device
• Safe operation in the event of a
short circuit
• Vent mechanism for safer operation in
case of abuse
Part No.
CR17335
Cell Type
Primary, non-rechargeable
Chemistry
Lithium Manganese Dioxide
Voltage Range
1.5 to 3.3V
Nominal Voltage
3.0V
Nominal Capacity
1500mAh @ 10mA to 2.0V @ 23°C
Max. Continuous Discharge Current
1500mA
Max. Pulse Discharge Current
Up to 3000mA (life and temperature dependent)
Weight
18g
Operating Temperature
-40°C to 60°C
Storage Temperature
-40°C to 60°C (max 30°C for a >5 years life)
Exterior/Housing
Nickel plated steel
Terminals/Connector
Radial tabs / radial pins / axial leads / flying leads
Safety
AL-MSDS/RD-003 and UN/UL (see note)
Transportation
Excepted from regulations - A complete description
of transportation regulations, lithium weights and
transportation classifications is available on the
Ultralife website.
Note
UL certified as a technician replaceable battery
only
Quality Assurance
Ultralife manufacturing facilities are ISO 9001:2008
and ISO 14001:2004 registered. Its products are
listed under the Component Recognition Program
of Underwriters Laboratories (UL) and have
passed UN transportation testing, which is required
for international transportation of all lithium
batteries.
Typical Applications
• Military and other radio applications
• Smoke alarms and security systems
• Beacons and emergency location
transmitters
• GPS
• Metering systems
• Sono buoys
• LED lighting applications
CR17335
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2013 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 18 DEC 13 UBM-0060 Rev: A
Dimensions
Typical Performance Graphs
Constant Load Discharge Voltage versus Discharge Time at 25°C
CR123A
CR17335
3.4
Discharge Voltage (V)
3.2
3.0
2.8
2.8Ω-900mA-1.0Ah-1.1h
2.6
5.4Ω-500mA-1.1Ah-2.2h
14.8Ω-200mA-1.2Ah-6h
2.4
305Ω-10mA-1.5Ah-145h
3150Ω-1mA-1.6Ah-1600h
2.2
10000.0
1000.0
Discharge Time (h)
100.0
10.0
1.0
0.1
2.0
High and flat voltage at high and low drain
CR17335
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2013 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 18 DEC 13 UBM-0060 Rev: A
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising